Router Connection Details

Size: px
Start display at page:

Download "Router Connection Details"

Transcription

1 The TSL Tally and UMD Configuring Program Router Connection Details Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0) , FAX +44 (0) Routers

2 Contents 1 GVG Encore & SMS 7000 Family Routers 2 Harris / Leitch Routers 3 Network Routers 4 Pesa Routers 5 Thomson/Philips/BTS Routers 6 ProBel Routers 7 Quartz Routers 8 Sony Routers; MVS/DVS Series, 9 Sigma Routers 10 NVision Routers Appendix 1 TallyMan Router support as at April 2008 Note: Please check pin functions with connector details published for the routers as these connections shown might be out of date. V2.6 May 08 2 Routers

3 1 GVG Encore & SMS 7000 Family Routers The cable details in the boxes refer to the cable connectors. In TallyMan be sure to set priority numbers for the active Router Buses and set the correct Level, with the ASCII code. The SMS7000 needs an AMEZI serial interface to be installed. Start with Level 0 in the TallyMan settings. The system will only import the names that exist on the selected level. The level names can be viewed under "Edit Levels". The Grass Valley Encore/SMS 7000 router is different from other manufacturers routers in that it uses only names to identify the following: levels inputs outputs. The TSL TallyMan Controller uses the names that are programmed into the router to deduce the cross point information. The TallyMan program will allow access to the up-loading of the router s names when the Configure Router Names button is pressed in the main screen. In the TallyMan program, in the Router Properties box menu item, the video level could show something like 0:128SDV The leading part of the names in the UMD Controller must match exactly the names in the router, including case, punctuation and spacing. The easiest way to ensure this has happened is to select Configure Router Database Names an then import them to the UMD mnemonics. Allow a few moments (10~20 secs) for the update box to appear, when OK is pressed. However, if the Encore/SMS 7000 names are, say, only 5 characters long, any default name in the Edit router source names box e.g. SRCE 1, will not be completely overwritten. For example, the 1 part of SRCE 1 will remain. This is so user-mnemonics may be added to the TSL router lists as long as the leading names/mnemonics match those from the SMS7000. V2.6 May 08 3 Routers

4 Router Names may be copied across to the UMD mnemonics. Current software will overwrite the names entirely on a router upload but the user can then still enter the additional user-mnemonic part. e.g. CAM1 Bob Bob is the user- entered part of the mnemonic. CAM1 has been uploaded from the SMS This facility will be especially useful for 16 character displays. Connections The TallyMan Controller usually connects into the SMS 7000 router via the ASYNC I/F connector(s), depending on configuration of the SMS If more than one connector is fitted, it can configured either be as MAIN/STANDBY or as two separate control connectors. There may be one or two serial ports available on the SMS Either can be used, as long as the port is set correctly. The connector supports both RS232 and RS422 standards. The TallyMan Controller is fitted with an RS422 interface (connected as a Device), and is identified by being a socket on the chassis. The Encore routers use a RJ45 connector. Cable details CONTROLLER TM1/TM2 CONTROLLER TMC-1 GVG SMS 7000 ROUTER RS-422 RS-422 J1, RS-422 D9 Plug D9 Skt D25 plug 2 1 TX RX RX TX+ 2 4, 6 5 GND 7 CONTROLLER TMC-1/TM1/TM2 GVG SMS 7000 ROUTER RS-232 J1, RS-232 D9 D25 Socket 2 RX 3 3 TX 2 4 DTR 6/8 5 GND 7 7 RTS 4 8 CTS 5 V2.6 May 08 4 Routers

5 RJ 45 connections for Encore Also please see Notes below CONTROLLER TM1/TM2 CONTROLLER TMC-1 GVG SMS 7000 ROUTER ENCORE FRAME XX RS-422 RS-422 COM 2, Serial 1-8 D9 Plug D9 Skt RJ TX RX RX TX+ 1 4, 6 5 GND 4, 5 Check the configuration of the Encore/SMS 7000 for it to work with the UMD TallyMan Controller. Be sure to Set SMS7000 Native in the protocol selection box. The configuration is as follows. Communication details. Baud rate 9600 Parity NONE Stop Bits 1 Data Bits 8 Protocol NATIVE Notes Although the Encore/SMS 7000 does not provide an automatic update of status changes within the router, it is interrogated for changes that have occurred since the last request. This is done about 5 times a second, so a UMD display should respond within about ¼second. If the Comms are good between the Encore/SMS 7000 and the TallyMan Controller, and TallyMan is online when the 7000 name database is changed, there should be an automatic update shown in TallyMan. Amendments for recent Encore Frames (July 2007) RJ 45 For Encore Frame xx 1 Rx+ 2 No Connect 3 Tx+ 4 Ground 5 Ground 6 Rx- 7 No Connect 8 Tx- RJ45 For Encore Frame xx 1 Tx+ 2 Tx- 3 Ground 4 Ground 5 Ground 6 Ground 7 Rx- 8 Rx+ V2.6 May 08 5 Routers

6 2 Harris / Leitch Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a RS422 Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. Start with Level 0 set in the TallyMan dialog box. With a RS422 data/led checker, background polling on the communications link must be seen both ways at the rate of about once a second. The Leitch router acts as a Controller. These routers may connected to the TallyMan Controller via either a RS232 or a reverse connected RS422/485 link. Cable Requirements CONTROLLER TMC- 1/TM1/TM2 RS-232 D9 LEITCH ROUTER D9 Socket 2 RX 3 3 TX 2 5 GND 5 TM1/TM2 CONTROLLER RS- 422 TMC-1 CONTROLLER RS- 422 TSL Functions LEITCH ROUTER D9 Plug D9 Skt D9 Socket 3 3 RX RX SCN TX TX SCN 6 For TM1 and TM2; 2 & 7 and 3 & 8 are twisted pairs. Communication details. Baud 9600 / 38K4 No Parity 8 Bits 1stop Bit For Integrator models Set the Integrator Serial 1 Port on the Logic Module to RS422 by suitably fitting the links the correct way up. Set the baud rate for Serial Port 1 to and Set RH Serial Port 1 Protocol switches 1 and 2 to Leitch (Auto Detect). For Leitch router levels 1 and 2 set the TSL levels in TallyMan to Levels 0 and 1 respectively etc. V2.6 May 08 6 Routers

7 Leitch VIA32 Router The cable details in the boxes refer to the cable connectors. The router cable is normally plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. Leitch VIA32S series routing switchers. The control port on the TallyMan Controller should be fitted with an RS232 interface. This is identified as a D9 plug mounted on the rear of the TallyMan Controller. The SERIAL CONTROL connector on the rear of the LEITCH frame is connected to the TSL TallyMan Controller. The settings are as follows: Communication details. RS baud 8 bit data No parity One stop bit The configuration DIP switches should be set as shown: (See Fig 2-5, P2-6 in the Leitch Installation & Maintenance Manual). S1 S2 On S1-5 [ON] sets flow control on. S1-6 [ON] sets echo mode on. S1-7,8 [OFF] sets baud rate to 9600 Baud. An interface cable should be made up as below. CONTROLLER TMC-1/TM1/TM2 D9 LEITCH ROUTER Serial Control Port D9 Socket GND 7 During operation, TallyMan is listening for status messages from the LEITCH router, identifying the cross-points as they are made. In addition, the TallyMan carries out a background poll of the LEITCH router at the rate of 1 bus per second. V2.6 May 08 7 Routers

8 For Platinum Models Set the protocol in Tallyman as Leitch X-Y Passthrough. Set the router size in TallyMan Set up the appropriate matching communications parameters on the Harris PTR-RES Platinum Resource Module (card) and in TallyMan Set the Matrix number in TallyMan at 0 Initially set the Level number in TallyMan at 0 or check Multi Level and set the appropriate numbers on levels for the router. Using a Terminal program with the PC attached to the other Harris serial port will allow crosspoint changes to be made locally. Settings: 38K4/8/N/1. No Flow Control. Press Q to see the Command Summary screen When successfully On-Line, the Router Object will appear in TallyMan with a bright green dot alongside and activity will be seen in Tools > Router Mimic at the instant of a crosspoint change. Cable details TM1/TM2 CONTROLLER RS- 422 TMC-1 CONTROLLER RS- 422 TSL Functions HARRIS ROUTER D9 Plug D9 Skt D9 Socket 3 3 RX RX SCN TX TX SCN 6 V2.6 May 08 8 Routers

9 3 Network Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. TallyMan Programming The Router Level is the same as the Router s Address. For example, if the Router Address is 0, the Level that must be set in the Tallyman Router Properties box is 0. All Midi data links must be fitted for operation. TallyMan Controller RS232 details CONTROLLER RS 232 CONNECTORS D9 CONNECTOR RX 7 RTS 3 TX 8 CTS 4 DTR 9-5 0v Cable Details CONTROLLER TMC-1/TM1/TM2 RS-232 D9 Network Router RS-232 D9 Plug 2 RX TX 2 3 TX RX 3 5 GND 5 Communication details. 19K2 for 16 x 16, 32 x 32 and 64 x 64. Early V 16 x 16 routers are 9600 Baud No Parity 8 Bits 1 Stop Bit The maximum cable length is 15m. V2.6 May 08 9 Routers

10 4 Pesa Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. TallyMan Programming. The Router Level that must be set in the main screen in Router Properties Menu is 0. Be sure to set Router Bus priorities in TallyMan. Router Programming Open the CPU Link window. Select Port 2. Set the Baud Rate as Set the Stop Bits at 1 Select Protocol Type as USP. Set Check Sum as None. Set the Terminator as CR-Carriage Return Check all boxes in the Status Filter Select OK. Normal RS232 Connections Cable Requirements CONTROLLER TMC- 1/TM1/TM2 RS-232 D9 PESA RS-232 D9 Socket GND N/C 9 V2.6 May Routers

11 Hardware Information PESA J13/J14 RS 232 Connectors D9 Plug on equipment FUNCTION 1 CD 2 RX 3 TX 4 DTR 5 GROUND 6 DSR 7 RTS 8 CTS 9 N/C Hardware Information PESA J15 Connector FUNCTION D9 Plug on equipment 1 GROUND 2 RX+ 3 TX- 4 GROUND 5 N/C 6 GROUND 7 RX- 8 TX+ 9 GROUND RS 422/485 Connections Cable Requirements TM1/TM2 CONTROLLER RS-422 TMC-1 CONTROLLER RS-422 PESA ROUTER RS-422 D9 Plug D9 Skt D9 Socket SCN SCN 6 V2.6 May Routers

12 TallyMan Programming General The Pesa router is different from other manufacturers routers in that it uses names and levels to identify the following: levels inputs outputs. TallyMan uses the names that are programmed into the router to deduce the cross point information. The TallyMan program will allow access to the up-loading of the router s names when the Configure Router Names button is pressed in main router screen. In the TallyMan program, in Router Properties, the Level could show something like 0:128SDV The leading part of the names in the Controller must match exactly the names in the router, including case, punctuation and spacing. The easiest way to ensure this is to force an Import Router Database Names to Mnemonics. This is achieved via the Configure Router Names button. Allow a few moments (10~20 secs) for the update box to appear, when OK is pressed. User-mnemonics may be added to the TSL router lists as long as the leading names/mnemonics match those from the Pesa Router. Router Names may be copied across to the UMD mnemonics. V2.6 May Routers

13 5 Thomson/Philips/BTS Routers The cable details in the boxes refer to the cable connectors. The router cable is normally plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. The Jupiter VM3000 needs to be programmed with a set of CP input and output tables, for the ASCII interface to the Controller (similar to setting up a control panel). This will allow which sources and destinations TallyMan looks at by compiling these tables. The ASCII protocol used does not support transfer of mnemonics between the Jupiter and third party Controllers; this is a limitation imposed by Philips. Routers Using BTS ASCII Interface In order for TallyMan to communicate with the router, the correct type of interface must be installed and configured inside the router main frame. One serial port, on the rear of the BTS control system must be allocated for use with TallyMan and configured as an ASCII port. The Source and Destination tables must be built for this port and the file saved back to configure the router. The connector supports both RS232 and RS422 standards. The serial interconnection cable between the BTS router and the TallyMan Controller should be wired as shown below. CONTROLLER TMC-1/TM1/TM2 RS232 D9 BTS ROUTER ASCII PORT(7), RS232 D9 Socket 2 RX 3 3 TX 2 5 GND V2.6 May Routers

14 CONTROLLER TM1/TM2 CONTROLLER TMC-1 BTS ROUTER RS422 RS422 ASCII RS422 D9 Plug D9 Skt D9 plug 2 1 TX TX GND RX RX GND 6 The BTS router serial port used by TallyMan needs to be set up as: Communication details. Baud Rate: 38K4 with ASCII interface Data bits: 8 Parity: None Stop bits: 1 Refer to the BTS Control system (Installation & Operation) manuals for details on: Hardware Installation... BTS ASCII 2-49 (computer interface protocol) Software Installation... Serial protocol 3-28 MPK devices 3-44 Notes. During operation, TallyMan initiates a Watch Output command, at the rate of 1 bus per second for each for each bus it is interested in. The router immediately replies with a status as well as responding to any changes on that bus. For the ASCII interface within the Jupiter config, you must define sets of inputs, outputs and levels and associate them with the ASCII configured port. The index numbers on the left of these sets determine the numbers sent in the ASCII protocol to TallyMan. If unsure of level number, then tick the "Multi Level" box in TM and specify e.g. 8 levels. It is, however normally preferable to operate as single level if you are only interested in one level, as it removes unnecessary compilations in subsequent programming. Note that only those levels specified in the CP Level set will appear on the interface. V2.6 May Routers

15 6 ProBel Routers The cable details in the boxes refer to the cable connectors. In TallyMan be sure to set priority numbers for the active Router Buses. Problems with communication are invariably due to incorrect configuring of the ProBel port. Check whether the protocol set in the router is SWP02 or SWP08. System - General Setup Set the number of the router video and matrix levels. For General Remote Protocol, System 3 (SWP08), Aurora and Freeway, this starts at 00 (zero). For General Switcher protocol, System 2 (SWP02), this starts at 01. Check in the router manual for router matrix number setting. If there is doubt as to the correct number, start at 0. A control port on the TallyMan Controller is fitted with an RS422 interface; this is identified as a D9 socket. In order for TallyMan to communicate with a router, it is necessary for the correct type of interface to be installed and configured inside the router main frame. ProBel routers need to have a Remote (communications) Port assigned and configured to act as an interface to TallyMan. In order to achieve this, a computer terminal needs to be connected to the router maintenance interface port and the router configured to the following specification: Communication details. General Remote Protocol SWP08 / General Switcher Protocol SWP02 RS baud 8 bit data No parity One stop bit Set the Remote Port to be General Remote or General Switcher protocol, as appropriate. ProBel port RS485/422 should be used. The serial interconnection cables between the PROBEL router and the UMD TallyMan controller should be wired as shown below for the particular application. V2.6 May Routers

16 Pin-out Details RS232 Connections where appropriate CONTROLLER PROBEL ROUTER Control Port D9 D9 Socket 3 (Tx) 3 2 (Rx) 2 5 (0v) GND 5/7 General Switcher protocol SWP02. RS422 Connections where there is a ProBel controller in the system. CONTROLLER TM1/TM2 CONTROLLER TMC-1 PROBEL ROUTER Control Port D9 Plug (D9 Skt) D9 plug ,6 5 GND 6,4 General Remote protocol SWP08. RS422 Connections where there is a ProBel controller in the system. CONTROLLER TM1/TM2 CONTROLLER TMC-1 PROBEL ROUTER Control Port D9 Plug D9 Skt D9 plug ,6 5 GND 6,4 V2.6 May Routers

17 RS422 Connections where there is no ProBel controller in the system. CONTROLLER TM1/TM2 CONTROLLER TMC-1 PROBEL ROUTER Control Port D9 Plug D9 Skt D9 plug ,6 5 GND 6,4 During operation TallyMan is listening for status messages from the ProBel router identifying the cross-points as they are made. In addition, TallyMan carries out a background poll of the ProBel router at the rate of 1 bus per second. For routers on different levels, an extra Router module will need to be inserted into the TallyMan tree and assigned to the existing one for the communications connections. Note: In case of no communications with the ProBel frame, please be prepared to try a 1:1 cable or crossed cable, as the case may be. Also, check the matrix level numbers set in TallyMan. V2.6 May Routers

18 7 Quartz Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. The Quartz routers, Q1600/Q3200, may not have a suitable serial interface installed and it must be fitted retrospectively if the routers were ordered without the interface board. The router serial interface may be configured as RS232 or RS422 by changing the position of the jumpers on the card. All jumpers must be set the same way. See the following charts for connection details. CONTROLLER TMC-1/TM1/TM2 RS-232 D9 QUARTZ ROUTER RS-232 D9 Plug 2 RX 7 3 TX 3 5 GND 6 CONTROLLER TM1/TM2 TMC-1 CONTROLLER RS- 422 FROM QUARTZ ROUTER RS-422 D9 Plug D9 Skt D9 Plug 3 3 RX Rx v Tx Tx v 6 The TallyMan Controller uses the default serial communication settings of the Quartz router. Use Quartz protocol (Quartz Type 1 or Quartz Native). Communication details / 38K4 baud (depends on version) 8 bits No parity 1 stop bit Note: The Matrix setting in TallyMan has no effect with Quartz Routers. If you have difficulty with finding the correct Level, check the Multi-level box in the TallyMan router dialog page and enter, say 4, in the Levels box. Then inspect the data in Tools > Tally Mimic to ascertain which level you want to read. Courtesy of Evertz Quartz UK V2.6 May Routers

19 V2.6 May Routers

20 8 Sony Routers MVS/DVS Series The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. The communication is RS422 and operates at 38K4 baud. ROT 16 is supported TM1/TM2 CONTROLLER RS-422 TMC-1 CONTROLLER RS-422 SONY ROUTER RS-422 D9 Plug D9 Skt D9 Plug SCN SCN 6 The protocol is multi-drop, allowing multiple devices to be on the bus. This allows for several routers to be controlled, or monitored from one serial port. Addressing on the Sony equipment is by means of a DIP switch. This address is designated Unit Address 2. Addressing is bit mapped. This allows operations to take place on more than one router at a time, i.e. Video + Audio etc. In the TallyMan Controller, the address is set by using the Video Level number and the addresses generated are as follows:- CONTROLLER VIDEO LEVEL DECIMAL SONY UNIT ADDRESS 2 HEXADECIMAL 1 1 0x x x x x x x x80 This facility precludes an automatic update from the router to the TallyMan Controller. This normally provides a quick update when a change occurs. With 16 or less outputs and inputs, the complete status can be requested and this is done twice a second to keep display update time reasonably short. Set the IP address to be in the same group as the TallyMan TMx unit. The Port in TallyMan must be set to Assign a spare SBUS number to the TM system. V2.6 May Routers

21 9 Sigma Routers Please check on the pin functions as shown in the manuals for the correct connectivity. Usually RS 232: Pin 2-3 Pin 3-2 Pin 5-5 Baud rate is fixed at 9600 in TallyMan. Switches will need setting in the MRX Router The MRX Router module is RS232 by default. Its logical address is 0 which corresponds to Matrix number 0 in the TallyMan program Handshaking should be set to OFF. Sigma Switch Settings: RS232 Baud Rate setting: S2-1 and S2-2 ON /DOWN Protocol format: S2-9, S2-10. S2-11 ON/DOWN Control Level: S2-12 DOWN/ON (8 Levels) Handshaking S3-2 OFF/UP 10 NVision Routers Connect using TCP/IP The level number corresponds to the physical level number (-1) in the NVision software. For multiple levels, each level should be entered as a separate router object, communicating with the same IP/port on the NVision router. V2.6 May Routers

22 Appendix 1 TallyMan Router support as at April 2008 Protocol Control Alphanumeric BTS ASCII Yes No GVG Native Yes From Router BTS ESSwitch Yes From Router Kramer Yes No Leitch Yes No Network Yes No NVision Yes From Router Pesa Yes From Router Quartz Yes From Router SBUS (ROT16) Yes From Router Sigma Yes No Sony Yes No SWP02 Yes No SWP08 Yes From Router Talia No No VikinX Yes No V2.6 May Routers

Apantac Tahoma Multiviewers - TSL interface

Apantac Tahoma Multiviewers - TSL interface Apantac Tahoma Multiviewers - TSL interface All Apantac Tahoma Multiviewers provide TSL protocol support for dynamic Labels and Tally Management as standard. With the current Tahoma FW version, the Version

More information

The TSL Tally and UMD Configuring Program. UMDs this section is intended to be read in conjunction with the Introduction

The TSL Tally and UMD Configuring Program. UMDs this section is intended to be read in conjunction with the Introduction The TSL Tally and UMD Configuring Program UMDs this section is intended to be read in conjunction with the Introduction Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone

More information

SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL

SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL SIGMA ELECTRONICS, INC. P.O. Box 448 1027 COMMERCIAL AVENUE EAST PETERSBURG, PA 17520 (717) 569-2681 SCI-2144 CONTENTS PAGE INTRODUCTION 2 RS-232

More information

Tallyman Controller Quick Configuration Manual

Tallyman Controller Quick Configuration Manual Tallyman Controller Quick Configuration Manual TallyMan V1.81 on Introduction 1 Contents Introduction... 3 Initial Setup... 4 Connecting to your TallyMan controller... 5 Adding a new component... 11 Configuring

More information

Multiviewer Information

Multiviewer Information The TSL Tally and UMD Configuring Program Multiviewer Information Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 Contents

More information

Attaching Inputs and Outputs

Attaching Inputs and Outputs Attaching Inputs and Outputs Inputs (sources) and outputs (destinations) attach to the input and output connectors on the rear of each enclosure. Inputs attach to the connectors on the left side of the

More information

Displays: UMDs and IMD (In Monitor Display) this section is intended to be read in conjunction with the Introduction

Displays: UMDs and IMD (In Monitor Display) this section is intended to be read in conjunction with the Introduction The TSL Tally and UMD Configuring Program Displays: UMDs and IMD (In Monitor Display) this section is intended to be read in conjunction with the Introduction Television Systems Limited. Vanwall Road,

More information

TRITON routing switcher

TRITON routing switcher TRITON routing switcher RS-422 Data Router 16x16 Product model no. TTN-BRS-1616 INSTALLATION MANUAL MANUAL PART NO. 04-052074-004 Rev. 2 MARCH 07, 2003 the most watched worldwide ii Headquarters Thomson

More information

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter

INDEX. Document Name : User Manual for SC10EJ Serial to Ethernet Converter Document Name : User Manual for SC10EJ Serial to Ethernet Converter Page 1 of 10 INDEX 1. Technical Specifications 1 2. Modes of Operation 1 3. Configuring the SC10 EJ : Through Serial Port 2 a. Configuring

More information

TABLE OF CONTENTS 1. GENERAL OVERVIEW OF 7700PTX OVERVIEW 7700PTX-GVTALLY... 2

TABLE OF CONTENTS 1. GENERAL OVERVIEW OF 7700PTX OVERVIEW 7700PTX-GVTALLY... 2 TABLE OF CONTENTS 1. GENERAL OVERVIEW OF 7700PTX... 1 1.1. OVERVIEW 7700PTX-GVTALLY... 2 2. CARD EDGE CONTROLS... 3 2.1. DETERMINING CURRENT IP ADDRESS SETTINGS... 3 2.2. RESTORING FACTORY DEFAULTS...

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

POS function. 1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

POS function. 1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking POS function Marchen POS-DVR surveillance system is a professional surveillance integrated with POS system. By bringing video and POS transaction data together, the POS-DVR surveillance system provides

More information

3.1 I-7560 Pin Assignment and Specifications: Introduction

3.1 I-7560 Pin Assignment and Specifications: Introduction 3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows

More information

I/O Interface DNA300

I/O Interface DNA300 DNA300 OPERATIONS MANUAL 1 Ring Communications, Inc. Crisis Alert System I/O Interface DNA300 2 DNA300 OPERATIONS MANUAL 2006/06/13 DNA300 OPERATIONS MANUAL 3 Contents INTRODUCTION... 5 INSTALLATION...

More information

Developer Information. Videohub. Includes Blackmagic Videohub Ethernet Protocol and Videohub RS-422 Protocol

Developer Information. Videohub. Includes Blackmagic Videohub Ethernet Protocol and Videohub RS-422 Protocol Developer Information Videohub Includes Blackmagic Videohub Ethernet Protocol and Videohub RS-422 Protocol May 2018 Contents Videohub Blackmagic Videohub Ethernet Protocol v2.3 3 Summary 3 Protocol Preamble

More information

Cable Pinouts. SRP I/O Module

Cable Pinouts. SRP I/O Module Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4

More information

DGH A3000 Configuration Guide For use with DGH Modules

DGH A3000 Configuration Guide For use with DGH Modules DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation

More information

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual The USBG-8COM-PRO 2-Port Series Industrial I/O Adapters are advanced USB to Serial Adapters that connect to 1, 2, 4 or 8 RS- 232/422/485

More information

MGate MB3000 Modbus Gateway User Manual

MGate MB3000 Modbus Gateway User Manual MGate MB3000 Modbus Gateway User Manual Sixth Edition, July 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. MGate MB3000 Modbus Gateway User s Manual The software described in this manual

More information

Extension module for BACnet over Ethernet / IP and graphic Web functions

Extension module for BACnet over Ethernet / IP and graphic Web functions s 9 265 9263p01 DESIGO PX Extension module for BACnet over Ethernet / IP and graphic Web functions Plugs into the modular automation stations, type PXC...-U PXA30-W2 For operation of the PXC -U automation

More information

Section 5: Applications

Section 5: Applications Quick Contents Overview External Aux Bus Control GVG CPL Control Timeline Control Section 5: Applications Section 5: Applications Overview This section provides setup instructions for interfacing Dveous/MX

More information

MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays

MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays ABB Application Note MSOC AN-64A-00 Substation Automation and Protection Division MSOC Communication Commonality with DPU/TPU/GPU 2000R Protective Relays Introduction There seems to be some confusion with

More information

DFS/Cutter. Debugging Communication Problems

DFS/Cutter. Debugging Communication Problems DFS/Cutter Technical Support Bulletin Debugging Communication Problems Abstract: This TSB is written to help users debug communication problems where the cutter appears to ignore everything the computer

More information

TM1 MK2 and TM1+ MK2 Installation Manual (SN on)

TM1 MK2 and TM1+ MK2 Installation Manual (SN on) TM1 MK2 and TM1+ MK2 Installation Manual (SN.68983 on) Serial Number: 68983 on TallyMan V1.87 on Introduction 1 Contents Introduction... 3 Installation... 4 TM1 MK2... 4 Connections... 4 Pin out details...

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an

More information

User Manual for VE GSM Modem

User Manual for VE GSM Modem User Manual for VE GSM Modem INTRODUCTION GSM/GPRS Smart Modem is a multi-functional, ready to use, rugged unit that can be embedded or plugged into any application. The Smart Modem can be controlled and

More information

Appendix A Cable Pinouts

Appendix A Cable Pinouts Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules

More information

MGate MB3000 Modbus Gateway User s Manual

MGate MB3000 Modbus Gateway User s Manual User s Manual Seventh Edition, May 2013 www.moxa.com/product 2013 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used

More information

Protocol Translation Functions

Protocol Translation Functions Firmware Installation, Configuration, and Operation Manual Protocol Translation Functions Edition E PTF MAN Delivering the Moment Publication Information 2014 Imagine Communications Corp. Proprietary

More information

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual First Edition, June 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. MGate EIP3000

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

Installation and Programming Manual

Installation and Programming Manual MUCM SATO Printer Application Manual MUCM SATO Installation and Programming Manual This Manual describes the MUCM application for interfacing a SATO M-8400 barcode printer to an MUCM. Effective: 18 May,

More information

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM24x Quick-Connect Industrial Modem. User s Manual ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of

More information

Extension module for graphic Web functions for one automation station

Extension module for graphic Web functions for one automation station s 9 266 9263p01 DESIGO PX Extension module for graphic Web functions for one automation station Plugs into the modular automation stations, type PXC...-U For operation of the PXC -U automation stations

More information

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. SC10B is Bluetooth V.2.0-certified and is backward compatible with v1.1/1.2 devices. You can connect between your computers (Master)

More information

The TSL Tally and UMD Configuring Program. Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction

The TSL Tally and UMD Configuring Program. Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction The TSL Tally and UMD Configuring Program Power Supply PSU-22 this section is intended to be read in conjunction with the Introduction Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6

More information

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual The USB to industrial 16-Port RS-422/485 Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your

More information

NV9000 Control System NV920S NV920D. NV960/NV965/NV967 Router Controllers NV960 NV965 NV967

NV9000 Control System NV920S NV920D. NV960/NV965/NV967 Router Controllers NV960 NV965 NV967 NV920S 1 RU single module controller, frame, dual power supplies The NV920 is a 1 RU enterprise-class box that can be configured to be either a single or a dual NV9000 controller, all in a single 1 RU

More information

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.:

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.: Technical Documentation VISY-X Edition: 2016-10 Version: 1 Article no.: 350033 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07 0 Fax: +49 / 40 / 39 06 339 Table of contents

More information

User s Guide. Ethernet Module for Barcode Printer

User s Guide. Ethernet Module for Barcode Printer User s Guide Ethernet Module for Barcode Printer 1. ETHERNET MODULE... 2 1-1. Functions... 2 1-2. General Specifications... 2 2. ETHERNET MODULE INSTALLATION... 3 2-1. Ethernet Module Installation for

More information

AUTOLOG GSM-PLC STEP BY STEP

AUTOLOG GSM-PLC STEP BY STEP AUTOLOG GSM-PLC STEP BY STEP AutoLog GSM4 Unit with power supply: Open the cover with screwdriver (GSM4 Unit in picture): Open the cover with screwdriver (GSM14 Unit in picture): AutoLog GSM4 Unit with

More information

Extension module for Web functions generic

Extension module for Web functions generic s 9 264 9263p01 DESIGO PX Extension module for Web functions generic Plugs into the modular automation stations, type PXC...-U PXA30-W1 Extension module for PXC -U automation stations in the DESIGO building

More information

RS 232 Interface. RS 232 is the Serial interface on the PC. Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3

RS 232 Interface. RS 232 is the Serial interface on the PC. Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3 RS 232 Interface RS 232 is the Serial interface on the PC Three major wires for the Serial interface: Transmit Pin 2 Receive Pin 3 Note: SR510 switches pins 2,3 internally HP Func. Gen. Requires a null

More information

Bluetooth TO Serial CONVERTER E-P132-B

Bluetooth TO Serial CONVERTER E-P132-B Bluetooth TO Serial CONVERTER E-P132-B 1 Table of Contents Introduction..3 Package checklist...4 Product Specification...5 Product Panel Views Description...6 Product Views. 6 DC-In Power Outlet 6 Antenna

More information

Datasheet Kaleido-XQUAD Simplified Standalone Quad-Split Multiviewer with Dual Quad-Split Upgrade Capability

Datasheet Kaleido-XQUAD Simplified Standalone Quad-Split Multiviewer with Dual Quad-Split Upgrade Capability Datasheet Kaleido-XQUAD Simplified Standalone Quad-Split Multiviewer with Dual Quad-Split Upgrade Capability A clear view for any of your monitoring requirements. Kaleido-XQUAD from Grass Valley, a Belden

More information

Cabling Guide for Console and AUX

Cabling Guide for Console and AUX Page 1 of 13 Cabling Guide for and AUX Ports TAC Notice: What's Changing on TAC Web Help us help you. Contents Introduction Before You Begin Conventions Prerequisites Components Used Table of Routers with

More information

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US I-7560U/7561U/7563U User Manual USB tto RS--232//422//485 Converrtterrss Verr.. 1..0,, Decc.. 2013 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of

More information

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual Third Edition, Dec. 2008 www.korenix.com Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

More information

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter

Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter Installation Guide of Hi-Speed USB to Octal RS-232/422/485 Adapter Introduction The USB to Octal Serial Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your

More information

FEC-240G. Rev. Date

FEC-240G. Rev. Date Model User s Manual Contents Contents. 1 Features... 2 Type Model and Serial Number... 2 Specifications... 3 Interface Connections...... 4 DIP Switch Setting... 6 Dimension... 7 Command Set Table... 8

More information

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual Bluetooth to RS-232 Converter RT-132B Bluetooth Adaptor Operation Manual First Edition, Nov 2007 Table of Contents 1. Introduction.. 2 2. Package checklist.. 3 3. Product Specification... 4 4. Product

More information

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual USB to RS-232/RS422/485 US-101-I USB To Serial Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel Views Description

More information

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS007 is a universal data converter which support serial RS232, RS422 and RS485 to the TCP / IP intelligent communication converter, it offers RS485/RS422

More information

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 1.0 Introduction A Technical Application Note from Doppler Systems April 11, 1999 Version 3.x of the DDF6000, running

More information

USER MANUAL. GSM Modem Option. Compatible with: DB46, DB7012

USER MANUAL. GSM Modem Option. Compatible with: DB46, DB7012 USER MANUAL GSM Modem Option Compatible with: DB46, DB7012 Publish Date: 06-Mar-2018 GSM MODEM OPTION - FEATURES AND USAGE The described Features and Usage of the GSM Option is compatible with following

More information

GEM80 & ewon Setup Quick Guide

GEM80 & ewon Setup Quick Guide Introduction to the ewon The ewon is an intelligent, programmable Ethernet Gateway, which can be used to bridge GEM 80 PLCs onto an Ethernet network, via the PLC serial port (Port3). This provides network-based

More information

X-Series System Manual Part 7: Interfaces and data communication

X-Series System Manual Part 7: Interfaces and data communication X-Series System Manual Part 7: Interfaces and data communication Version check: Version No. Date Version 3.1 April 2012 Version 3.0 April 2011 Version 2.0 October 2007 Version 1.0 March 2006 Mettler-Toledo

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-01-26 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

TRP-C37M User s Manual

TRP-C37M User s Manual TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed OCT. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651) Wrenchman, Inc. 1801 Old Hwy. # 8 Suite # 122 New Brighton, Minnesota 55112 (651) 638-9012 468X Interface Cable Specifications The Interface Cable emulates the Async RS-232 logical interface supported

More information

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED NTI R NETWORK TECHNOLOGIES INCORPORATED 1275 Danner Dr Aurora, OH 44202 Tel:330-562-7070 Fax:330-562-1999 www.nti1.com KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE KEEMUX Series MAN049

More information

Unique Micro Design First Choice of Professional Systems Intergrators. Model 361 Terminal Keyboard Wedge User Manual

Unique Micro Design First Choice of Professional Systems Intergrators. Model 361 Terminal Keyboard Wedge User Manual Model 361 User Manual Unique Micro Design First Choice of Professional Systems Intergrators Model 361 Terminal Keyboard Wedge User Manual Document Reference : DOC-M361-UM UMD Part Number : 6-0361-993-5

More information

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD BOARD LEVEL PRODUCTS RS-422/ INTERFACE BOARD DESCRIPTION The Model Serial Interface is a small, low cost interface board that interfaces serial devices with RS-422 or signals to the bus. The provides

More information

Tel: Fax:

Tel: Fax: NP302 Series 2-port RS-232 232/485/422 to Ethernet Serial Server User manual Shenzhen 3onedata Technology Co.,Ltd Tel: +86-755-26702688 Fax: +86-755-26703485 www.3onedata.com Contents 1. Introduction...

More information

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB APPENDIXB This appendix lists the cable specifications for supported modules on the Cisco 7600 series router. The following signal summaries are contained in this appendix: Interface Specifications, page

More information

Series 370 Stabil-Ion Gauge Controller with RS-485 Interface Option

Series 370 Stabil-Ion Gauge Controller with RS-485 Interface Option Series 370 Stabil-Ion Gauge Controller with RS-485 Interface Option Introduction The RS-485 communications option (See Figure 1) for the Series 370 Stabil-Ion Gauge Controller permits data output to, and

More information

Comments and/or suggestions concerning this document are welcome and should be directed to:

Comments and/or suggestions concerning this document are welcome and should be directed to: &38/LQN3URWRFRO1R 3 'RFXPHQW1R5HYLVLRQ% 3(6$6ZLWFKLQJ6\VWHPV,QF $:\QQ'ULYH1RUWKZHVW +XQWVYLOOH$/ KWWSZZZSHVDFRP 6HUYLFHDQG2UGHULQJ$VVLVWDQFH 3(6$6ZLWFKLQJ6\VWHPV,QF $:\QQ'ULYH1RUWKZHVW +XQWVYLOOH$/86$

More information

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index

Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Document Name: User Manual for SC10EK4 Serial to Ethernet Converter with 4 TCP Sockets. Index Technical Specifications 1 Installation Procedure 1 LED Indications 2 Configuration Procedure Configuration

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

General Specifications

General Specifications General Specifications GS 48D50Z00-00E-N C0-950-00 Basic Communication System ProSafe-COM A major part of this functionality is mapped upon an industrial PC, thus representing ProSafe- COM. The basic hardware

More information

420 Series RS232 only Encoder for Keypad Applications Application / Engineering Manual

420 Series RS232 only Encoder for Keypad Applications Application / Engineering Manual USA OFFICE UK OFFICE Suite 202 14 Bentinck Court 364 Pennsylvania Avenue, Bentinck Road Glen Ellyn West Drayton Illinois 60137 UB7 7RQ USA ENGLAND Tel +1 (630) 469 2981 Tel +44 (0) 1895 431421 www.keymat.com

More information

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package. USB-4COMi-M USB to Quad RS-422/485 to Serial Adapter Manual The USB to Industrial Quad RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple. Connecting to a USB

More information

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL PAGE 1 OF 9 1. GENERAL The Avanti I²C Transducer Tester and PC-Interface (AVA-03) is a standalone device for accessing pressure/temperature transducers, which are equipped with a two-wire serial I²C interface.

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-08-23 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM. 8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments

More information

PDS200 Power over Ethernet Device Server User Manual

PDS200 Power over Ethernet Device Server User Manual PDS200 Power over Ethernet Device Server User Manual ABOUT PDS200 is an external usage Power over Ethernet Device Server (Serial-to- Ethernet converter). It includes the function of GIGA-TMS s products-

More information

USER MANUAL FOR GS100/GS1003G

USER MANUAL FOR GS100/GS1003G USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...

More information

SSI Serial Pump Control

SSI Serial Pump Control Scientific Systems, Inc. 349 N. Science Park Road State College, PA 16803 Phone (814)234-7311 Fax (814)238-7532 E-Mail sales@ssihplc.com Control Specifications: SSI Serial Pump Control Series 3 1K buffer

More information

MB40 & MB45 MODBUS TCP/IP Gateway Handbook

MB40 & MB45 MODBUS TCP/IP Gateway Handbook MB40 & MB45 MODBUS TCP/IP Gateway Handbook Version 1.2 29 July 2014 Environdata Australia Pty Ltd 42-44 Percy Street Warwick Queensland 4370 Australia Phone: (07) 4661 4699 Fax: (07) 4661 2485 International

More information

THOR Router Management System. Quick Start Guide. Version 3.5

THOR Router Management System. Quick Start Guide. Version 3.5 THOR Router Management System Quick Start Guide Version 3.5 Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 E-mail: support@network-electronics.com

More information

18 December September June April 2013

18 December September June April 2013 18 December 2013 10 September 2013 18 June 2013 16 April 2013 Added note that Harris Platinum and LRC protocol version requires Router Control v2.4.6. See New Features in Release v2.4. Added support for

More information

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel

More information

ZLAN5443A. User Manual

ZLAN5443A. User Manual ZLAN5443A Serial Device Server User Manual 4 ports RS232/485/422 To TCP/IP converter CopyRight 2008 Shanghai ZLAN Information Technology Co., Ltd. All right reserved Document DI: ZL DUI 20150413.1.0 1

More information

Serial to Ethernet Converter

Serial to Ethernet Converter Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem

More information

Older Compaq UPS Family - Identifying Serial Communication Cables

Older Compaq UPS Family - Identifying Serial Communication Cables Older Compaq UPS Family - Identifying Serial Communication Cables In this document: Overview Cables Supplied 6 Ft. Communication Cable 12 Ft. Communication Cable Older Compaq UPS Family Communication Port

More information

RC Configuration and Installation Guide

RC Configuration and Installation Guide Kramer Electronics, Ltd. RC Configuration and Installation Guide Revision 8 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version, go to the

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual The USB-COMi-TB USB-to-Industrial Single RS-422/485 Adapter is designed to make industrial communication port expansion quick and simple.

More information

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual 5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

STEPware-100 Operations Manual

STEPware-100 Operations Manual STEPware-100 Operations Manual 1 STEPware-100 Operations Manual Your Industrial Control Solutions Source www.maplesystems.com Maple STEPware100 Systems, Operations Inc. Manual 808 134 th St. SW, Suite

More information

BOARD LEVEL PRODUCTS OEM GPIB<->RS-232 INTERFACE BOARD GPIB

BOARD LEVEL PRODUCTS OEM GPIB<->RS-232 INTERFACE BOARD GPIB BOARD LEVEL PRODUCTS OEM INTERFACE BOARD Description The Model Interface is a small, low cost interface board that interfaces devices to the bus. The provides a smart IEEE-488.2 compliant, to-serial

More information

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Introduction & Specifications of Hi-Speed USB to Serial Adapters Introduction & Specifications of Hi-Speed USB to Serial Adapters The USB Serial Adapters consist of the following models: USB Single Serial Adapter (ES-U-1001, ES-U-1001-A) USB Single Serial Adapter (ES-U-1001-M,

More information

Technical Note. Configuration process to control domes connected to VT units with the Supervisor software handset

Technical Note. Configuration process to control domes connected to VT units with the Supervisor software handset Technical Note Configuration process to control domes connected to VT units with the Supervisor software handset Revision date September 2005 Application Supervisor (3.61 and later) VT200 (3.5 and later)

More information

Features. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter

Features. Target Applications. V1.6 TBS07 RS485 to SDI-12 Converter The is an interface box for connecting a PC, data logger or telemetry unit to one or more sensors with SDI-12 interface. The connects to a data logger, telemetry unit or other device with RS485 interface

More information

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China. FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

More information

Matrix-710. Linux-Ready Cortex-A5 Industry IoT Gateway. Hardware Guide. Version: Nov.

Matrix-710. Linux-Ready Cortex-A5 Industry IoT Gateway. Hardware Guide. Version: Nov. Matrix-710 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide Version: 1.01 2017 Nov. Copyright Artila Electronics Co., Ltd. All Rights Reserved Trademarks The Artila logo is a registered trademark

More information

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card EX-45362 & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card Congratulation on your purchasing this high performance 2-Port RS232/422/485 3-in-1 Serial PCIe Host Adapter. The adapter is high speed PCIe

More information

Unique Micro Design. Advanced Thinking Products. Model 164 Quad Coupler User Manual

Unique Micro Design. Advanced Thinking Products. Model 164 Quad Coupler User Manual Advanced Thinking Products Model 164 Quad Coupler User Manual Document reference : UMD Part Number : 6-0164-993-4 Issue 1 - First release Revision 2/12/92 Advanced Thinking Products Model 164 Quad Coupler

More information

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2)

Doug Fleenor Design, Inc. RS-232 to DMX512 Interface, 2 Generation. March 8, 2010 (Software V1.2) Doug Fleenor Design, Inc. nd RS-232 to DMX512 Interface, 2 Generation March 8, 2010 (Software V1.2) The second generation RS-232 to DMX512 interface has numerous features beyond the original device. The

More information