MICROSENS. Modular CWDM/DWDM-Multiplexer System. Introduction

Size: px
Start display at page:

Download "MICROSENS. Modular CWDM/DWDM-Multiplexer System. Introduction"

Transcription

1 Modular CWDM/DWDM-Multiplexer System MICROSENS Introduction Increasing bandwidth requirements resulted from rising amount of transferred data leads inevitably to the higher demand for the backbone capacities. Solution to this problem can be shifting of new glass fibers, yet it is connected with high costs, planning, time and formalities. A faster and more economical solution is the more efficient use of existing fiber lines through the active wavelength multiplexing called also WDM - Wavelength Division Multiplexing. With the WDM technology different wavelengths are used for the parallel transfer of several signals. The WDM systems of MICROSENS permit immediate and above all economical capacity development of existing fiber lines for telecommunications providers, ISPs, operators of metro networks as well as for enterprises with large networks. The users can optimally use their dark fiber connections with these systems. With the application of the MICROSENS WDM technology the utilizable capacities can be adapted flexibly and fast to the requirements of backbone connections. By implementing the cost-efficient CWDM technology MICROSENS sets in its modular WDM systems an optimal scalability together with lower initial costs. With this technology MICROSENS offers the possibility to cover data transmission rate of up to 40 Gbit/s on standard optical fibers. The main application for this multiplexing system is CWDM technology, however DWDM can also be used, especially for applications that require more optical channels capacity (32, 48 etc.). This datasheet describes mainly CWDM functionality, the additional information about DWDM options and parameters of this system can be found in further documentation of appropriate DWDM modules (MUXs/DeMUXs/SFPs)

2 Modular CWDM/DWDM-Multiplexer Page 2/26 WDM-Technology The fiber offers an additional advantage, which enables a further, substantial capacity increase apart from the well-known advantages of the high bandwidth in long transmission connections. Since light of different wavelengths does not influence itself mutually, the transfer capacity can be multiplied by the simultaneous transfer of data with different wavelengths in an optical fiber. This technology is called wavelength multiplex or WDM (Wavelength Division Multiplexing). The simultaneous transfer can take place both in one transmission direction, and in addition, in opposite directions. The optical coupler of the wavelength multiplexers bundles the different light wavelengths and transfers the entire light stream, which contains all discrete wavelengths, over one fiber-optic cable to the receiving place, where it is separated by means of filter techniques into the individual channels. The number of channels available on a glass fiber at the same time is limited theoretically only by the technical feasibility. If a very small wavelength distance is selected, then a high channel number in only one optical window can be accommodated. DWDM systems (Dense WDM) based on this technology are used particularly in the long-distance traffic area. Critical technical factor of a DWDM system is the stability of the optical components, primarily of the transmission lasers. In order to achieve a wavelength stability within the nanometer area, very large electrical and thermal stabilization are necessary, which make the components expensive. Latest technology within the wavelength multiplex area is the CWDM (Coarse WDM). With these systems the channel spacing of the individual wavelengths is multiple times larger in the comparison to the DWDM technology (approx. 20 nm). Thus the requirements towards laser technology are reduced, which affects drastically the entire system costs.

3 Modular CWDM/DWDM-Multiplexer Page 3/26 Fig 1. CWDM and DWDM wavelengths according to ITU G & G The optical windows with wavelengths of 850 nm, 1300 nm and 1550 nm can be used for the transfer (see the following diagram). Fig. 2. Transmission parameters of the glass fiber For xwdm transmission the third optical window with a wavelength of 1550 nm is used, in which the different colours light signals are transferred. With the CWDM technology the light stream between 1470 nm and 1610 nm is divided on up to 8 wavelengths, whereby on each wavelength 2.5 Gbit/s can be transferred. Optionally it is possible to use second optical window with the light stream between 1470 nm and 1610 nm for transmission of inband management or another 8 CWDM channels. Please note however that maximum distance is significantly lower if second optical window is used for CWDM transmission.

4 Modular CWDM/DWDM-Multiplexer Page 4/26 Compared with DWDM systems the initial costs of the newest CWDM technology are substantially more favourable. Thus new target groups start to use this technology. Apart from telecommunications providers also private customers, maintaining larger network or several locations in one city, successfully deploy these cost-efficient solutions. Features With the use of optical multiplexer on the basis of CWDM technology a fast and simple reduction (8:1) of required optical connections is possible. The modular design makes an efficient and economical extension of the system possible. The optional SNMP management function enables a central controlling by administrator. The modular CWDM system can transfer up to eight independent high-speed services over a single mode fiber. The individual channels are transparent for the transferred data, they can transmit various service protocols from 100 Mbit/s up to max. 2.5 Gbit/s e.g. Fast Ethernet, ESCON, ATM OC-12/OC-48, 1G and 2G Fibre Channel, SDH STM-1/4/16 and Gigabit Ethernet. significant cost saving by using Coarse WDM technology up to 16 independent services on one glass fiber connection optimal expandability due to modular transceiver cards and pluggable transceivers. The local connections are realized by GBIC/SFP plug-in transceivers. optimal investment utilization. Only actually used ports are installed. line interface duplex (2 fibers) or simplex (1 fiber) optional Line-Protection. The output channel is transmitted parallel over two independent fiber lines thus the transmission is secured in case of fiber damage. service friendly due to minimum necessary spare part stock optical budget of min. 24 db. Distances of min. 80 km are possible to cover in addition to the simple point-to-point connection the system supports also building of complex linear add/drop and ring structures compact form, 19 chassis 4 HU with 28 module slots the multiplexer can be monitored by an integrated management module through SNMP (Simple Network Management Protocol) and web based management. Easy integration in SNMP management platforms is guaranteed.

5 Modular CWDM/DWDM-Multiplexer Page 5/26 Applications The main advantage of the multiplexer lies in the increasement of the capacity of existing glass fiber infrastructure, which is called "multiplex operation" e.g. by the bundling of several services on a transmission fiber. A further advantage is the possibility of coupling of heterogeneous networks, with the parallel transmission of different services e.g. Gigabit Ethernet, Fibre Channel and ATM. Fig. 3: Coupling of heterogeneous networks Thanks to its modular design MICROSENS CWDM multiplexer is high-grade scalable and can be economically adapted to the requirements of the network. Beside linear add/drop structures it is possible to build ring structures with this system.

6 Modular CWDM/DWDM-Multiplexer Page 6/26 Fig. 4: Parallel transmission of telecommunication services (SDH) and data Active Wavelength Conversion The transfer of the single channels takes place by means of the wavelength multiplexing equipment. Thereby a unique wavelength is assigned to each channel of the multiplexer system. Channels on the line side are operating in third optical window with a channel spacing of 20 nm each. CWDM 20 nm spacing ITU G optical power nm wavelength Fig. 5: CWDM channel spacing The modular system concept is based on the use of special CWDM lasers, which are laid out as GBIC/SFP transceiver modules. Thereby these cost-intensive system components can be used only in the actually needed quantity. Besides, service and maintenance are substantially simplified and the costs of spare part stock are minimized.

7 Modular CWDM/DWDM-Multiplexer Page 7/26 Fig. 6: Local/CWDM Laser - SFP Transceiver Description The actual SFP transceivers from MICROSENS offer an optical transmission over multimode or single mode fiber. Depending on the model the transceiver can cover distances up to 120 km. The SFP (Small Form Factor Pluggable) is based on the same principle as the GBIC. The main difference is the size of the transceiver with only half of the width (mechanical dimensions) due to the use of the LC connector. The optical transceiver from MICROSENS comply to the SFP specifications Revision Additional they are compliant to the Gigabit Ethernet specifications according IEEE Std , the Fibre Channel specifications FC-PH, PH2, PH3, FC-PI 10.0 and all common ATM (OC-12, OC-48) and Sonet (SDH STM-4, SDH STM-16) standards. The transceivers are available with different wavelengths. For multimode applications such as Gigabit Ethernet, Fibre Channel or Double Rate Fibre Channel VCSEL lasers with a wavelength of 850 nm are used. This allows to realise distances up to 550 m using a 50/125 µm multimode fiber. For single mode applications there are FP and DFB lasers with the wavelengths of 1310 and 1550 nm available. Depending on the model it is possible to cover distances from 10 km up to 120 km. The transceivers offer the highest flexibility and can be installed during operation (hot swap).

8 Modular CWDM/DWDM-Multiplexer Page 8/26 Technical Specifications of SFPs modules* Type Fiber type SFP (Small Form Factor Pluggable) Transceiver for data transmission up to Gigabit speed Multimode 62,5/125 or 50/125 µm, duplex, Single Mode 9/125 µm duplex, LC-connector Data Rates 622 Mbps to 1.25 Gbps (optional Gbps) Multimode Wavelength: 850 nm MM VCSEL min. optical power: -10 dbm min. opt. sensitivity: -20 dbm min. distance: 550 m (50 µm), 275 m (62,5 µm) Single Mode Wavelength: 1310 nm SM FP Laser min. optical power: -8 dbm -7 dbm 10 km / 25 km min. opt. sensitivity: -22 dbm -24 dbm min. distance: 10 km 25 km Single Mode Wavelength: 1550 nm SM DFB Laser min. optical power: -5 dbm 0 dbm 0 dbm 50 km / 80 km / 120 km min. opt. sensitivity: -24 dbm -24 dbm -32 dbm min. distance: 50 km 80 km 120 km Data Rates up to 2,488 Gbps Multimode Wavelength: 850 nm MM VCSEL min. optical power: -9 dbm min. opt. sensitivity: -18 dbm min. distance: 550 m (50 µm), 275 m (62,5 µm) Single Mode Wavelength: 1310 nm SM FP Laser min. optical power: -10 dbm -5 dbm 2 km / 15 km min. opt. sensitivity: -20 dbm -20 dbm min. distance: 10 km 25 km Single Mode Wavelength: 1550 nm SM DFB Laser min. optical power: -5 dbm 0 dbm 15 km / 80 km min. opt. sensitivity: -20 dbm -29 dbm min. distance: 50 km 80 km Data Rates CWDM up to 1,25 Gbps Single Mode Wavelength: 1470 nm nm SM CWDM Laser min. optical power: -0 dbm 0 dbm 50 km / 80 km min. opt. sensitivity: -23 dbm -29 dbm min. distance: 50 km 80 km Data Rates CWDM up to 2,67 Gbps Single Mode Wavelength: 1470 nm nm SM CWDM Laser min. optical power: -0 dbm 0 dbm 50 km / 80 km min. opt. sensitivity: -20 dbm -29 dbm min. distance: 50 km 80 km Operating temperature 0 C to 60 C Standards CDRH and IEC class 1 eye safety Supply Voltage 3,3 V * only sample SFP modules are given. For additional options and parameters please refer to additionalsfp datasheet.

9 Modular CWDM/DWDM-Multiplexer Page 9/26 Diagnostic Function (optional) Optional the transceivers are available with Diagnostic function (Extension of article number with D, e.g. MS100200D), to monitor detailed all operating information. This offers to read information such as optical transmit power, receive power, the optical budget, the resulting possible distances and the real used data rate via the management system. This feature is particular useful in combination with the MICROSENS xwdm systems, because it increases the functionality significant. CWDM transceiver modules* for applications with data rates from 0.1 up to max Gbit/s: Pos. Art.-No. Wavelength Color Description 1 MS100214D nm Grey SFP 1.25Gb, 1470nm, Single Mode, 80km 2 MS100214D nm Violet SFP 1.25Gb, 1490nm, Single Mode, 80km 3 MS100214D nm Blue SFP 1.25Gb, 1510nm, Single Mode, 80km 4 MS100214D nm Green SFP 1.25Gb, 1530nm, Single Mode, 80km 5 MS100214D nm Yellow SFP 1.25Gb, 1550nm, Single Mode, 80km 6 MS100214D nm Orange SFP 1.25Gb, 1570nm, Single Mode, 80km 7 MS100214D nm Red SFP 1.25Gb, 1590nm, Single Mode, 80km 8 MS100214D nm Brown SFP 1.25Gb, 1610nm, Single Mode, 80km CWDM transceiver modules* for applications with data rates from 0.1 up to max Gbit/s: Pos. Art.-No. Wavelength Color Description 1 MS100272D nm Grey SFP 2.5Gb, 1470nm, Single Mode, 80km 2 MS100272D nm Violet SFP 2.5Gb, 1490nm, Single Mode, 80km 3 MS100272D nm Blue SFP 2.5Gb, 1510nm, Single Mode, 80km 4 MS100272D nm Green SFP 2.5Gb, 1530nm, Single Mode, 80km 5 MS100272D nm Yellow SFP 2.5Gb, 1550nm, Single Mode, 80km 6 MS100272D nm Orange SFP 2.5Gb, 1570nm, Single Mode, 80km 7 MS100272D nm Red SFP 2.5Gb, 1590nm, Single Mode, 80km 8 MS100272D nm Brown SFP 2.5Gb, 1610nm, Single Mode, 80km * additionally wavelengths from second optical window as well as other options including DWDM lasers, different optical budget options, different max. throuput are also available

10 Modular CWDM/DWDM-Multiplexer Page 10/26 4 Channel Optical Crossbar Transponder with SFP-Ports 4 Channel Optical Crossbar Transponder to connect up to four fiber segments with optional complete signal regeneration. Due to the complete signal regeneration (3R) of the transponder, the signal distortion caused by the transmission over long distances is compensated. The transponder can operate in two modes: Transparent transponding: the input signal is not reclocked, only colour of wavelength is changed 3R regeneration: the input signal is completely refreshed and clock is rebuilt The process of complete signal regeneration is usually called '3R' (reamplification, reshaping, retiming) and regenerates the amplitude, the curvature and the timing of the transmitted signal. The deployment of transponders with retiming functionality enables the implementation of far longer transmission distances, and allows cascading several longdistance transponders with sub-segment lengths of up to 120 kilometres (75 miles) each. Optical Crossbar Transponder has got four installed modular SFP ports instead of permanent optical modules. The use of pluggable optical transceivers (SFPs) offers the highest flexibility for the implementation of different transmission distances. Beside the transparent transponding and retiming function the module can be configured to following operation modes using the integrated crossbar: Redundant configuration (protection of fiber links) Channel protection (protection of active lasers or complete module) Crossbar (all SFP ports freely interconnect able) Broadcast (1:n broadcast application) Using SFPs with digital diagnostics interface it is possible to monitor the status information of the SFP via the chassis management. It is possible to read information such as wavelength, optical transmit and receive power and other information. The transponder is laid out in form of a plug-in module card, which is installed into MICROSENS modular converter system. Beside the standalone chassis in single and double version, there is a special 19"-Chassis for mounting up to 12 modules. In combination with the MICROSENS SNMP management module (MS B) the converter can be supervised by SNMP/Web-based management. A further feature places an alarm contact (non-potential), which can be used for the connection to external alarm system.

11 Modular CWDM/DWDM-Multiplexer Page 11/26 Connectors There are the following connections on the front side of the module: PWR ALARM Tx 1 Rx Tx 2 Rx Tx 3 Rx Tx 4 Rx ON EN LK ON EN LK ON EN LK ON EN LK SFP Port 1 SFP Port 1 SFP Port 1 SFP Port 1 Optical Crossbar Alarm Alarm Contact - Configuration Due to a free programmable internal clock the converter does the signal regeneration for any protocol and data rate, e.g. ATM OC-3, SONET/SDH STM-1 (155 Mbps), ATM OC-12/ SONET/SDH STM-4 (622 Mbps), Gigabit Ethernet (1.25 Gbps), ATM OC-48/ SONET/SDH STM-16 (2488 Mbps), and others within the range of 100 Mbps up to 2.7 Gbps. The signal amplitude (1R), the signal form (2R) and the signal timing (3R) are regenerated. The selection of transmission rate is made via the management of the additional management agent module (MS B). Link Through Via the management software it is possible to activate or deactivate the Link Through function. The Twin Wide Range Retimer supports Link Through (LT) function in FX/FX retimer application. The link status on one port is propagated to the other port to notice the remote nodes. If one of the fiber port is unplugged, this converter stops transmission on the other fiber port. A Remote site Link error B Management alarm Location A Converter with Link Through Location B with network management

12 Modular CWDM/DWDM-Multiplexer Page 12/26 LED displays The status of the converter is indicated over 15 LEDS on the front side. Two general LEDs for the whole module: PWR ALARM LED Name Description PWR Power Module is ready ALARM Alarm Alarm is on Three LEDs for each SFP port: ON EN LK LED Name Description ON Laser On Transmit Laser on EN Enable Port able to transmit data In protection mode: On: active protection port Off: standby protection port LK Link Flashing: receiving optical signal On: Retimer lock Alarm contact The alarm contact enables the monitoring of the converter condition over an attached external signal generator. In case of a failure of the power supply of the module the alarm contact switches into the alarm condition. There are two different options how the alarm is provided at the relay contact, normally open or normally closed. The pinout of the alarm contact is shown in the following figure and table: C NC NO Alarm PIN Name Description C Common Common contact for NC and NO. NC Normally Closed Closed to common in normal operation, open in case of alarm. NO Normally Open Open to common in normal operation, closed in case of alarm. When connecting external devices the maximum contact stress of the connection must be considered. Never connect 230 V AC to this contact!

13 Modular CWDM/DWDM-Multiplexer Page 13/26 Technical Specifications of Optical Crossbar Transponder Type Connectors Data rate 4 channel Optical Transponder module to connect up to four fiber segments with integrated crossbar, protection and broadcast feature 4x SFP ports 100 Mbps up to 2.7 Gbps (free configurable internal clock) LED displays PWR Standby ALARM Fiber link error or power down ON Laser on EN Port enabled LK Link / clock locked Alarm contact Power supply potential free, max. 60 V DC, max. 0,5 A 12 V DC / max. 400 ma via Backplane Operating temperature 0 C to 55 C Storage temperature -20 C to 80 C Relative humidity Dimensions 5% to 80% non condensing 3 HE x 6 TE (128 x 31 mm)

14 Modular CWDM/DWDM-Multiplexer Page 14/26 Passive multiplexing (MUX) / demultiplexing (DeMUX) Due to the flexible design it is possible to realise different network topologies, depending on the application: Point-to-Point-Topology In this configuration the data channels are transmitted in parallel between two locations. In the end points standard MUX/DeMUX units are used, which are combining and splitting the optical wavelengths. It is possible to reach a minimum distance of 80 km. For the maximum possible distance the attenuation of the fiber is the limiting factor. Fig. 7: Point-to-Point-Topology The passive multiplexer (MUX) and demultiplexer (DeMUX) are designed as a modular card. In normal configuration a 8 channel multiplexer and a 8 channel demultiplexer are used. In case that the configuration is changed, these cards can be replaced by add/drop modules, due to the modular design (see next chapter). CWDM Channel λ1 1 CWDM Channel λ2 2 CWDM Channel λ3 3 CWDM Channel λ4 CWDM Channel λ5 4 Mux/ Demux 5 8 ch. 9 Line Interface λ1, λ2,..,λ8 CWDM Channel λ6 6 CWDM Channel λ7 7 CWDM Channel λ8 8 Fig. 8: CWDM MUX/DeMUX Combining the wavelengths

15 Modular CWDM/DWDM-Multiplexer Page 15/26 Linear-Add-Drop-Topology This is an extended point-to-point topology, where several nodes can be added between the end nodes. At these additional nodes it is possible to drop (take out) or to add (put in) single channels out of or into the fiber (see fig. 9). With a correct design it is possible to route the channels between any two nodes of the network. In the end nodes there are standard MUX/DeMUX units used. Designing the network it has to be considered that each add/drop multiplexer has its own attenuation, so that the total possible distance is reduced. Fig.. 9: Linear-Add-Drop-Technology The passive add/drop modules are available in different versions, which are having a different number of add/drop channels. Standard versions are the one, two and four channel add/drop modules. Because of the modular design it is possible to reconfigure existing multiplexer end system to add/drop units.

16 Modular CWDM/DWDM-Multiplexer Page 16/26 Ring-Topology Especially in the telecom area the use of ring structured networks is preferred, because this offers the highest security combined with a minimum use of fiber (see fig. 11). If the ring is interrupted at one location, the data traffic can be kept upright if the network is designed in this way. To build the ring structure it is necessary to use add/drop multiplexer in all nodes. With the correct design it possible to transmit the channels between any two nodes. Fig. 10: Ring-Topology Fig. 11: Example of wavelength add/drop

17 Modular CWDM/DWDM-Multiplexer Page 17/26 Passive xwdm MUX/DeMUX Modules* MICROSENS is expanding its product portfolio of optical Metro solutions by introducing new passive multiplexers for multiplying transmission capacities of fiber optical connections. By using passive multiplexers, several optical channels of different wavelengths can be combined, which will allow multiple services to the transmitted together via fiber without interference. What makes this possible is the fact that different light colours (wavelengths) do not affect each other. These components will make realizing CWDM and DWDM applications easy. Passive construction of the module permits its use for various applications including: - Fast Ethernet - ESCON, - STM-1/OC-3, STM-4/OC-12, STM-16/OC-48, STM-64/OC Gigabit Ethernet, - Fibre Channel - Double Rate Fibre Channel, - 10 Gigabit Ethernet For transmission, light colours are multiplexed onto an fiber using a wavelength-specific filter (multiplexing). At the other (receiving) end of the line, the wavelengths are divided again, or rather, demultiplexed. Hence, any transmission line consists of a multiplexer and a demultiplexer. For bi-directional transmission, both start and end points will then require the appropriate multiplexers and demultiplexers. Since we are dealing with true passive multiplexing, the individual optical signals must already be available in their respective wavelengths. The multiplexers are then selected according to the different wavelengths (window, number of channels, and wavelength difference). The design of these components emphasizes ease of installation and start-up of operations, as well as consistent modularity for optimal adaptability to given communication requirements. The multiplexer/demultiplexer rack modules are part of a wide product range of functional modules for installation in modular rack systems from MICROSENS. In addition to desktop housings, users can select a 19 chassis with up to 12 slots. When using multi-slot chassis, the converter may be combined with any other modules from the Enterprise Access family. In addition, the MICROSENS product portfolio offers active converters for optical or electrical/optical adaptation of data channels to the appropriate wavelengths and required ranges. These converters are also based on the modular system of the Enterprise Access family, allowing band-widths of up to 2.5 Gbit/s per channel. Depending on combination and wavelengths, ranges of up to 80 km can be realized. Using WDM as transmission technology, network operators can build an infrastructure that may be expanded depending on need. In addition, the capacities in all sub-areas of the network are expandable. This represents an advantage no other technology can provide. Using passive multiplexers is of interest for cable network operators, too. This technology will allow providing additional services such as combining bi-directional data services with unidirectional TV transmission without any problem, while using the existing infrastructure. * only sample MUX/DeMUX is described. For additional options and parameters please refer to additional MUX/DeMUX datasheets.

18 Modular CWDM/DWDM-Multiplexer Page 18/26 Device CWDM Channel λ CWDM Channel λ CWDM Channel λ CWDM Channel λ CWDM Channel λ CWDM Channel λ CWDM Channel λ CWDM Channel λ Line Passive CWDM Module MICROSENS Line Interface λ1, λ2,..,λ8 Function CWDM Channel λ1 1 CWDM Channel λ2 2 CWDM Channel λ3 3 CWDM Channel λ4 CWDM Channel λ5 4 Mux/ Demux 5 8 ch. 9 Line Interface λ1, λ2,..,λ8 CWDM Channel λ6 6 CWDM Channel λ7 7 CWDM Channel λ8 8 Connection The use of the multiplexer and demultiplexer is always done in a pair. From CWDM-GBIC Receive Transmit Mux DeMux MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS MICROSENS Notes Duplex fiber Line side Output (TX) The above diagrams show only basic point-to-point applications units. Further modules enable building add/drop configurations and adding service channels to the transmissions. Input (RX)

19 Modular CWDM/DWDM-Multiplexer Page 19/26 Technical Specifications of passive MUX/DeMUX modules Fiber type Single Mode 9/125 µm SC/APC-connector (Line Interface) SC/PC-connector (Channel Interface) CWDM Channels According to ITU G.694.2, spacing 20 nm: 1290 nm, 1310 nm, 1330 nm, 1350 nm, 1370 nm, 1390 nm, 1410 nm, 1430 nm 1470 nm, 1490 nm, 1510 nm, 1530 nm, 1550 nm, 1570 nm, 1590 nm, 1610 nm Channel width min. +/- 6,5 nm Channel Isolation min. 30 db (adjacent) min. 45 db (non adjacent) Insertion Loss max. 2,5 db per channel Return Loss min. 40 db Flatness max. 0,5 db Power supply 12 V DC / max. 100 ma via system backplane (for management only) Operating temperature 0 C to 55 C Storage temperature -20 C to 80 C rel. Humidity 5% to 80% non condensing Dimensions 31 x 128 x 170 mm (w x h x d) Notes The passive Mux/DeMUX modules are belonging to a big range of 19 system modules and are available in many different versions/options suitable for various applications. The basic types include point-to-point and add/drop modules (with variable number of add/drop channels). A power supply is not necessary for the passive modules.

20 Modular CWDM/DWDM-Multiplexer Page 20/26 Passive Line Interface Module (Optional) The standard xwdm systems are using MUX/DeMUX modules. The outputs of these modules are operating as the line interface. Using one 8 channel MUX (transmit direction) and one 8 channel DeMUX (receive direction), the system is offering one duplex line interface. One fiber (simplex) is used for the transmit direction and the other one for the receive direction. Simplex Line Interface The use of a special coupler offers the possibility to use one fiber (simplex) for both, transmit and receive direction without any interference. In this case the same wavelength is used for the transmit and the receive direction. By using existing duplex fiber connection it is possible to transmit up to 16 channels on one fiber pair. These direction dependent couplers are reducing the usable optical budget about db per side. Standard Simplex DeMux MUX Line Protection Module Fig. 12: Simplex Interface At this type of protection between two locations, the data is transmitted in parallel over two different fiber connections. To have a useful protection the two fiber connections should have a different route. On the receive side an optical switch is doing the selection of the active line. If the active line is interrupted the switch is switching automatically to the second backup line. The switching time is under the 50 ms switching time which is required in SDH networks. This type of protection secures interruptions of the fiber connections between the locations. A protection against failures of the active parts of the device is not given by this module. This option can be used only for the point to point connection. A combination of the line protection with the simplex interface is not recommended. Reflections on the fiber can cause malfunction on the line protection module. Protected West Protected East Fig. 13: Line Protection with optical switch

21 Modular CWDM/DWDM-Multiplexer Page 21/26 Management The connection with the Ethernet network is made by the RJ-45 socket of the module, which supports 10/100Base-TX connections. The Ethernet port allows a connection of an end device or a switch/hub. The connection to an end device has to be done with acrossed patch cable. The automatic rate adjustment with the receiving station is made by the integrated Autonegotiation function. The access is done using the TCP/IP protocol. The following applications are supported: SNMP SNMP is the standardized protocol for the integration of the equipment management in standard management platforms e.g. HP open View or IBM Tivoli. The access to the internal data structures of the equipment is made by the Management Information Base (MIB-II). In order to make an access over SNMP to the components data possible, the integration of the data structure of the MIB into the network management is necessary. The structure of the MICROSENS MIB can be loaded by HTTP download from MICROSENS Web Manager. The MIB file is in the ASCII format. http (Webserver) The integrated management agent web server based on HTTP protocol enables access by a standard Internet Browser (e.g. Microsoft Internet Explorer or Netscape Navigator). Device status is visualised graphically (GUI). Terminal + TELNET All equipment functions can be configured and queried also via a local serial port. This terminal is also available over the network port by means of Telnet protocol. FTP The integrated software of the agent is put down in a Flash ROM. It can be updated by FTP download over the network at any time. During the update no impairment of the data traffic of CWDM data channels takes place.

22 Modular CWDM/DWDM-Multiplexer Page 22/26 Configuration Examples Due to the modular design and the chassis based concept there are many different configurations possible. The following figures are showing some examples. MUX/DeMUX Active Interface modules with Retiming and GBIC-Slots Management Fig. 14: Standard configuration as 8 channel xwdm-system MUX/DeMUX Active Interface modules with Retiming and GBIC-Slots MUX/DeMUX Management Fig. 15: Configuration as 8 channel CWDM Retimer System Fig. 16: Configuration as 1 channel Add/Drop System with 3R-Retimer based on the 1 HU chassis

23 Modular CWDM/DWDM-Multiplexer Page 23/26 Technical data Type Optical multiplexer for parallel, transparent transmission of 8 channels over one fiber optic line Fiber type Bandwidth Data rate Local connector Multimode 62.5/125 or 50/125 µm, duplex, Single Mode 9/125 µm duplex, LC-connector 40 GBit/s (16x 2.5 Gbit/s per channel in each direction) max. 2.5 Gbit/s (STM-16) per channel CWDM Port wavelength: nm SM 80 km min. opt. budget: 24 db min. distance: 80 km (dependant on fiber type) Alarm contact Power supply Floating, max. 60 V DC, max. 0,5 A V AC, Hz, max. 90 W V DC, Hz Operating temperature 0 C to 55 C Storage temperature -20 C to 80 C Rel. humidity 5% to 80% non condensing Dimensions 450 x 400 x 174 mm (w x d x h)

24 Modular CWDM/DWDM-Multiplexer Page 24/26 Safety Notes Handling (installation of the system) CAUTION: Electrostatic discharges can destroy electronic components. Precautions against damage: An antistatic wristband connected to the multiplexer housing should be used during installation. Discharge any static electricity from your body and the system by touching the grounding terminal of the system housing for several seconds. Do not remove the system from packaging until immediately before installation. Do not touch any conductive parts of the system (components, soldering points, wires) and hold it by the mounting areas only. Electrical Safety DANGER! Conductive components of power and telecommunications networks can carry dangerously high voltage. To avoid electric shock: Do not carry out installation or maintenance work during lightning storms. All mains connections must be carried out via earthed mains sockets. All electric installations must be carried out in accordance with local regulations. Eye Safety DANGER! Optical components may radiate laser light. WARNING: Infrared radiation used for fiber optic data transmission, although invisible, may cause permanent damage to the human eye. To avoid damage to the eyes: Never look straight into the output of fiber optic components danger of blinding! Cover all unused optical connectors with protection caps. Establish the optical transmission link only after completing all connections. The active laser components used with this product comply with the specifications of Laser Class 1.

25 Modular CWDM/DWDM-Multiplexer Page 25/26 Order designation (sample modules only) Art.-Nr. Description Connectors MS416001M MS416010M MS416004M MS416005M MS416040M MS416453MR MS (D) MS (D) 19 Chassis 3 HU, 14 module slots, incl. Backplane 19 Chassis 3 HU, 28 module slots, incl. Backplane AC/DC VAC power supply (also redundant) DC 48 V power supply (also redundant) Fan Module for Modular System 4 Channel Optical Crossbar Transponder + Wide Range Retimer Module up to OC-48/STM-16, Active Local Interface (SFP), 850nm Multimode, max Gbit/s Active Local Interface (SFP), 1300nm Single Mode, min. 10 km, max GBit/s Backplane Backplane 4x SFP Slot 1x alarm contact 2 x LC 2 x LC MS (D) Active Local Interface (SFP), 850nm, max. 2,125 GBit/s, GBE, 1x/2x Fibre Channel" 2 x LC MS (D) Active Local Interface (SFP), 1300nm short reach, max. 2.5 GBit/s 2 x LC MS100213D-ww CWDM Line Interface max Gbps for STM- 1/OC-3, STM-4/OC-12, Gigabit Ethernet, 1x Fibre Channel, Single Mode CWDM Laser, LC connector, min. 23dB Budget MS100214D-ww CWDM Line Interface max Gbps for STM- 1/OC-3, STM-4/OC-12, Gigabit Ethernet, 1x Fibre Channel, Single Mode CWDM Laser, LC connector, min. 29dB Budget MS100270D-ww CWDM Line Interface max. 2.7 Gbps for STM- 1/OC-3, STM-4/OC-12, STM-16/OC-48, ESCON, Gigabit Ethernet, 1x/2x Fibre Channel, Single Mode CWDM Laser, LC connector, min. 20dB Budget MS100272D-ww CWDM Line Interface max. 2.7 Gbps for STM- 1/OC-3, STM-4/OC-12, STM-16/OC-48, ESCON, Gigabit Ethernet, 1x/2x Fibre Channel, Single Mode CWDM Laser, LC connector, min. 29dB Budget 2 x LC 2 x LC 2 x LC 2 x LC

26 Modular CWDM/DWDM-Multiplexer Page 26/26 MS100320D-nn MS100321D-nn DWDM Multirate Line Interface 100 Mbps..2.7 Gbps for Fast Ethernet, STM-1/OC-3, STM- 4/OC-12, STM-16/OC-48, ESCON, Gigabit Ethernet, 1x/2x Fibre Channel, Single Mode DWDM Laser, nn: ITU C-Band Channel 17-60, LC connector, min. 80km DWDM Multirate Line Interface 100 Mbps..2.7 Gbps for Fast Ethernet, STM-1/OC-3, STM- 4/OC-12, STM-16/OC-48, ESCON, Gigabit Ethernet, 1x/2x Fibre Channel, Single Mode DWDM Laser, nn: nn: ITU C-Band Channel 17-60, LC connector, min. 120km 2 x LC 2 x LC MS418360M Line Interface module simplex 3x SC MS419829M Line protection module (West/East) 4x SC MS416410M-nn 8 channel CWDM MUX and/or DeMUX module (for an 8 channel MUX/DeMUX system there are two modules necessary) MS416412M-nn 8 channel CWDM MUX and/or DeMUX module with express channel 1310 nm (for an 8 channel MUX/DeMUX system there are two modules necessary) MS416405M-nn 2 channel CWDM Add/Drop MUX and/or DeMUX (for an 8 channel MUX/DeMUX system there are two modules necessary) MS416408Mnnnn MS414020M-c- 22 MS414021M-c channel CWDM Add/Drop MUX and/or DeMUX (for an 8 channel MUX/DeMUX system there are two modules necessary) 8 Channel MUX DWDM, Local: 8x SC/PC simplex, Line: 1x SC/APC simplex 8 Channel DeMUX DWDM, Local: 8x SC/PC simplex, Line: 1x SC/APC simplex Local: 8x SC/PC simplex Line:1x SC/APC simplex Local: 9x SC/PC simplex Line:1x SC/APC simplex Local: 8x SC/PC simplex Line:2x SC/APC simplex Local: 8x SC/PC simplex Line:2x SC/APC simplex Local: 9x SC/PC simplex Line:1x SC/APC simplex Local: 9x SC/PC simplex Line:1x SC/APC simplex MS416361M- 3Mxx Multifunctional Twin Bridge for inband management 2x 10/100Base-TX, 2x 100Base- FX, Port1: Multimode 1300nm SC, Port2: xwdm 2x RJ45 (10/100TX) 2x SC duplex MS B SNMP Management Module, 1xRJ45 10/100Base-TX, 1xSUBD9 1x RJ45 (10/100TX) 1x SUB-D 9 (RS-232) * ww wavelength: nm, nm, nm, nm, nm, nm, nm, nm nm, nm, nm, nm, nm, nm, nm, nm * n channel number: nm, nm, nm, nm, nm, nm, nm, nm MICROSENS reserves the right to make any changes without further notice to any product to improve reliability, function or design. MICROSENS does not assume any liability arising out of the application or use of any product. 0807/tn

The configuration of the features can be done by the network management or the integrated configuration switches.

The configuration of the features can be done by the network management or the integrated configuration switches. Ethernet / Fast Ethernet Twin Bridge module MICROSENS Description Fast Ethernet Bridge The bridge enables connection of copper and fiber segments to Ethernet and Fast Ethernet whilst at the same time altering

More information

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power.

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power. WDM - MUX/DeMUX MX20-3155 Dual Channel WDM MUX/DeMUX 5 MX20-3155 is a dual channel, passive, protocol transparent, WDM multiplexer/demultiplexer which utilizes two popular WDM lambda channels of 1310nm

More information

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP. Manual Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T, 1x SFP Ports MICROSENS General The IP protocol has already left the in-house environment and is going to take all remaining communication

More information

5U CWDM Managed Platform SML-5000

5U CWDM Managed Platform SML-5000 CWDM Managed Platform 5U CWDM Managed Platform 5000 The SigmaLinks5000 is a flexible, cost-effective optical transport system, designed to multiplex, de-multiplex and switch high-speed data for storage,

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information

Cisco MDS 9000 Family Pluggable Transceivers

Cisco MDS 9000 Family Pluggable Transceivers Cisco MDS 9000 Family Pluggable Transceivers The Cisco Small Form-Factor Pluggable (), and X2 devices for use on the Cisco MDS 9000 Family are hot-swappable transceivers that plug into ports on the Cisco

More information

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP General The IP protocol has already left the in-house environment and is going to take all

More information

- 128 x Gigabit Ethernet connections - 32 x 4G Fibre Channel connections - 8 x 8G Fibre Channel connections - down to 2 Mbps

- 128 x Gigabit Ethernet connections - 32 x 4G Fibre Channel connections - 8 x 8G Fibre Channel connections - down to 2 Mbps Active WDM Company Introduction SmartOptics designs and markets all types of fibre optical transmission products. Headquarted in Oslo, Norway, we serve Storage, Data and Telecom Networks worldwide with

More information

Fig. 1: Entry Line Compact Gigabit Ethernet Converter

Fig. 1: Entry Line Compact Gigabit Ethernet Converter Entry Line Compact Industrial Fast/Gigabit Ethernet Converter 1x 100/1000Base-T 1x 100/1000Base-X (SFP Slot) MICROSENS General The IP protocol has already left the in-house environment and is going to

More information

SFP GBIC XFP. Application Note. Cost Savings. Density. Flexibility. The Pluggables Advantage

SFP GBIC XFP. Application Note. Cost Savings. Density. Flexibility. The Pluggables Advantage SFP GBIC XFP The Pluggables Advantage interfaces in the same general vicinity. For example, most major data centers have large Ethernet (and Gigabit Ethernet) networks with copper, multimode and single-mode

More information

SFCxx100PAxD SFP Dual fibre CWDM ITU CWDM / 100km / OC-48 Multirate.

SFCxx100PAxD SFP Dual fibre CWDM ITU CWDM / 100km / OC-48 Multirate. SFCxx100PAxD_RevA SFCxx100PAxD SFP Dual fibre CWDM ITU CWDM / 100km / OC-48 Multirate. For your product safety, please read the following information carefully before any manipulation of the transceiver:

More information

Optical Networking. Applications

Optical Networking. Applications Applications Allied Telesis Gigabit through 40G optical transport solutions empower IP/Ethernet service providers with a solution that leverages a common family of products and technologies from the customer

More information

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP)

CHIRON-4E1. E1 over Ethernet Multiplexer (TDM over IP) E1 over Ethernet Multiplexer (TDM over IP) Tranmission of up to 4x E1 PDH, G.703/704/723 E1 2048Mbit/s channels over Ethernet/IP network Built-in 5 port Gigabit Ethernet switch (4x 10/100/1000 Mbit/s RJ45

More information

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES DESCRIPTION FEATURES STM-1/OC-3 PDH/Ethernet terminal multiplexer for grooming LAN and legacy (TDM) traffic over SDH/SONET networks Ethernet traffic maps to: One VC-3/VC-4/STS-1 Up to 3 VC-3/STS-1 Up to

More information

CWDM MultiServicePlatform

CWDM MultiServicePlatform CWDM MultiServicePlatform 4/8 Channel Optical Multiplexer Protocol transparent Channel: Multimode, single mode 10 Mbit/s 2,5 Gbit/s 850, 1300nm Channel module with BFX-1 or CCM-1 Backup module with BFX-1

More information

CISCO WDM SERIES OF CWDM PASSIVE DEVICES

CISCO WDM SERIES OF CWDM PASSIVE DEVICES DATA SHEET CISCO WDM SERIES OF CWDM PASSIVE DEVICES Cisco Systems introduces its second generation of coarse wavelength-division multiplexing (CWDM) passive devices boasting increased functions and improved

More information

Fiber Optic Components Dedicated to supplying industry standard fiber optic components!

Fiber Optic Components Dedicated to supplying industry standard fiber optic components! Fiber Optic Components Dedicated to supplying industry standard fiber optic components! Authorized distribution provided in alliance with Sensible Micro Corporation 13520 Prestige Place Tampa, FL 33635

More information

Retired. HP CWDM Slot B 4-port Add/Drop Multiplexer. HP CWDM 8-port Multiplexer HP CWDM Multiplexer 2-Slot Chassis

Retired. HP CWDM Slot B 4-port Add/Drop Multiplexer. HP CWDM 8-port Multiplexer HP CWDM Multiplexer 2-Slot Chassis QuickSpecs Overview The HP Coarse Wave Division Multiplexer (CWDM) solution Family is a set of passive optical systems designed to provide optical network support for high-speed data Fibre Channel & Ethernet

More information

Optimux-34, Optimux-25

Optimux-34, Optimux-25 Data Sheet Optimux-34, Optimux-25 16-Channel E1/T1, Ethernet or Data over E3 or Fiber Multiplexers Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber opt7ic uplink E3 copper

More information

HARTING econ 3000 Introduction and features

HARTING econ 3000 Introduction and features Introduction and features HARTING econ 3000 es, unmanaged, for installation in control cabinets General Description Features The Fast es of the product family HARTING econ 3000 are suitable for industrial

More information

BWDM CWDM DWDM WDM TECHNOLOGY

BWDM CWDM DWDM WDM TECHNOLOGY BWDM CWDM DWDM WDM TECHNOLOGY INTRODUCTION User s of today s voice, video, and data networks are becoming more complex requiring more bandwidth and faster transmission rates over ever increasing distances.

More information

Gmux Modular TDMoIP Gateway FEATURES

Gmux Modular TDMoIP Gateway FEATURES FEATURES Carrier-class modular TDMoIP gateway, extending high capacity TDM traffic over packet-switched networks (PSNs) Operates opposite other members of RAD s TDMoIP family of products, offering a complete

More information

Application Note Fiber Connectivity

Application Note Fiber Connectivity Riedel Application solutions Note for - Fiber broadcast Connectivity applications 1 Content Fiber Basics Riedel Portfolio Application examples 2 Fiber Cable Propagation Modes Multi-mode Multiple modes

More information

Data Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 01 Overview About the Features Efficient Usage Supports up 18 to

More information

Increasing Fiber Capacity with CWDM

Increasing Fiber Capacity with CWDM Increasing Fiber Capacity with CWDM A Tutorial on CWDM Network Design Presented by: Greg Scott MSO/Telecom Sales Increasing Fiber Capacity with CWDM Introduction WDM Technology Overview CWDM and Fiber

More information

Brochure. WDM Solutions. Methods for Optimizing Fiber Capacity. Transition Networks Brochure.

Brochure. WDM Solutions. Methods for Optimizing Fiber Capacity. Transition Networks Brochure. Brochure WDM Solutions Methods for Optimizing Fiber Capacity Transition Networks Brochure Introduction to WDM Overview Demands on today s voice, video, and data networks are becoming more complex requiring

More information

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber

More information

Optical Metro 5040/5080 platforms

Optical Metro 5040/5080 platforms Optical Metro 5040/5080 platforms The Optical Metro (OM) 5040 and 5080 are highly-flexible CWDM/ DWDM access units that offer the broadest range of broadband services on a compact 1U platform. They extend

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

PHB-200M PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub

PHB-200M PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub SFP Patching Hub PHB-200M PHB-200 20x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub PHB-200M is a 20-channel Managed SFP patching hub that converts copper 100/1000Base-TX to SFPs working at 100Mbps

More information

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X SFP Patching Hub PHB-200M PHB-200 20x 100/1000Base-T to 20x 100/1000Base-X SFP Patching Hub PHB-200M is a 20-channel Managed SFP patching hub that converts copper 100/1000Base-TX to SFPs working at 100Mbps

More information

FRM220 Solution Portfolio

FRM220 Solution Portfolio FRM220 Solution Portfolio CTC Union Technologie s FRM220 series chassis solution is a multi-service chassis platform, which provides an economic and reliable solution in high density media converter installations

More information

Pluggable Transceivers, Module Connectors

Pluggable Transceivers, Module Connectors Pluggable Transceivers, page 1 Module Connectors, page 7 Pluggable Transceivers This section provides brief descriptions of the pluggable transceivers that can be installed in the switch modules and supervisor

More information

CWDM Products. Coarse Wavelength Division Multiplexing (CWDM) CWDM & Conversion for Optical Networks from the network connectivity experts

CWDM Products. Coarse Wavelength Division Multiplexing (CWDM) CWDM & Conversion for Optical Networks from the network connectivity experts Products Coarse Wavelength Division Multiplexing () & Conversion for Optical Networks from the network connectivity experts Transition Networks new products help you to alleviate fiber exhaustion and increase

More information

Optical Transport Platform

Optical Transport Platform Optical Transport Platform Bandwidth expansion on demand MICROSENS fiber optic solutions - intelligent, reliable, high-performance Optical Transport Platform The MICROSENS Optical Transport Platform provides

More information

Overview. Features CHAPTER

Overview. Features CHAPTER CHAPTER 2 This chapter provides these topics that describe the Catalyst 2955 switch, hereafter referred to as the switch. Features, page 2-1 Front-Panel Description, page 2-3 Rear-Panel Description, page

More information

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES FEATURES SDH/SONET terminal multiplexer for grooming LAN and legacy traffic (TDM) over SDH/SONET networks Demarcation point between the carrier and the customer networks GFP (G.7041), LAPS (X.85/86) encapsulation

More information

Industrial Gigabit Managed Ethernet Switch

Industrial Gigabit Managed Ethernet Switch HMG-828 HMG-828E Industrial Gigabit Managed Ethernet Switch Features High Performance Network Switching Technology Complies with IEEE 802.3, IEEE 802.3u, IEEE 802.3X, IEEE 802.1p, IEEE 802.1q, IEEE 802.1d,

More information

FB-10/100MMC Series Managed/Unmanaged. 10/100Mbps Fiber Media Converter User Manual

FB-10/100MMC Series Managed/Unmanaged. 10/100Mbps Fiber Media Converter User Manual FB-10/100MMC Series Managed/Unmanaged 10/100Mbps Fiber Media Converter User Manual (Version 1.5) Beijing Fibridge Co., Ltd. Content 1. Overview... 3 2. Features... 3 2.1. Hardware Features... 3 2.2. Software

More information

Demarcation Extension: Challenges and Solutions

Demarcation Extension: Challenges and Solutions Demarcation Extension: Challenges and Solutions Presented By Ty y Estes Marketing Communications Director And Allan Johns Senior Support Engineer Demarcation Extension: Challenges and Solutions Agenda

More information

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch Datenblatt / Datasheet Zubehör / Accessoires 1 Ha-VIS mcon 3000 Next Generation Introduction and features Ha-VIS mcon 3000

More information

Expert Line Managed Industrial Switch with M-Ring Function 6x 10/100/1000 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports)

Expert Line Managed Industrial Switch with M-Ring Function 6x 10/100/1000 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports) MICROSENS Expert Line Managed Industrial Switch with M-Ring Function 6x 10/100/1000 Base-TX, 2x 10/100/1000Base-T (100/1000 Base-X SFP Ports) General Ethernet is an international standard that has been

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator Media Converter Concentrator PHB-200M PHB-200 20x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator PHB-200M is a 20-channel Managed Media Converter that converts copper 100/1000Base-TX

More information

Ethernet Cards. 5.1 Ethernet Card Overview CHAPTER

Ethernet Cards. 5.1 Ethernet Card Overview CHAPTER CHAPTER 5 Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring

More information

DATASHEET Scalable & Flexible FMT 9600E Hyperscale DWDM Connect

DATASHEET Scalable & Flexible FMT 9600E Hyperscale DWDM Connect Data Center & Cloud Computing DATASHEET Scalable & Flexible FMT 9600E Hyperscale DWDM Connect FS.COM Optical Transport for Metro Networks OTN Solutions for Metro/Regional and Long Haul REV.1.1 2018 FMT

More information

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX KGC-352 Series Installation Guide DOC.070820-KGC-352-1- (C) 2007 KTI Networks Inc. All rights reserved. No part of this documentation

More information

WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B

WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B www.lumentum.com Data Sheet A flexible WDM transport solution The WRM-8008 is a next-generation OTN muxponder that can transparently aggregate

More information

ORION TELECOM NETWORKS INC.

ORION TELECOM NETWORKS INC. RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100,

More information

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer Modularized 16E1/T1 Managed Multiplexer FMUX01 Modularized 16E1/T1 + 4x GbE Managed FMUX1 Modularized 16E1/T1 + 4x FE Managed The FMUX01/FMUX1 is a 1U, 19" rack mountable, PDH fiber optic multiplexer that

More information

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high order legacy traffic (TDM) over SDH/SONET networks Any Traffic Over Fiber Multiplexes up to three E3 or T3 data channels using

More information

PHB-200M/PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub

PHB-200M/PHB x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub SFP Patching Hub PHB-200M/PHB-200 20x 100/1000Base-T to 20x100/1000Base-X SFP Patching Hub PHB-200M is a 20-channel Managed SFP patching hub that converts copper 100/1000Base-TX to SFPs working at 100Mbps

More information

Gigabit Ethernet Media Converter. User Manual

Gigabit Ethernet Media Converter. User Manual Gigabit Ethernet Media Converter User Manual (Version 1.2) Beijing Fibridge Co., Ltd. Contents 1. Overview... 3 2. Features... 3 3. Application... 5 4. Specification... 5 4.1. Ethernet Port... 5 4.2. Fiber

More information

Media Converters & Chassis

Media Converters & Chassis Expandable Chassis System The Chassis-based Media Converter product lineup includes various independent media converters and a chassis capable of housing up to 16 media converters. You can start with a

More information

VCL-TP, Teleprotection Equipment

VCL-TP, Teleprotection Equipment VCL-TP, Teleprotection Equipment Data Sheet Copyright: Valiant Communications Limited. - 2013 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable and flexible product that offers

More information

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc.,

RION ORION TELECOM NETWORKS INC. TELECOM NETWORKS. Optical Multiplexer Product Brochure. Orion Telecom Networks Inc., RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. 16 E1 + Gigabit Ethernet (Wire-Speed) Optical Multiplexer Product Brochure Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. Address: 20100, N

More information

Ethernet Cards. 5.1 Card Overview CHAPTER

Ethernet Cards. 5.1 Card Overview CHAPTER CHAPTER 5 Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring

More information

CWDM CASE STUDY DESIGN GUIDE. Line Systems, Inc. uses iconverter CWDM Multiplexers to overlay Ethernet onto SONET rings

CWDM CASE STUDY DESIGN GUIDE. Line Systems, Inc. uses iconverter CWDM Multiplexers to overlay Ethernet onto SONET rings DESIGN GUIDE CWDM CASE STUDY Line Systems, Inc. uses iconverter CWDM Multiplexers to overlay Ethernet onto SONET rings 140 Technology Drive, Irvine, CA 92618 USA 800-675-8410 +1 949-250-6510 www.omnitron-systems.com

More information

SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate

SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate DATASHEET - REV A SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate #01 Overview SBU35020DRx0 is a high performance transceiver module for Gigabit Ethernet and Fast

More information

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA V C ALIANT OMMUNICATIONS Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN, United Kingdom U.S.A. Valcomm Technologies Inc. 4000 Ponce de Leon,

More information

D9408 Advanced ATM Adapter

D9408 Advanced ATM Adapter Digital Transmission Equipment D9408 Advanced ATM Adapter Description The D9408 Advanced ATM adaptor enables broadcasters and telecom operators to take advantage of the added flexibility and cost savings

More information

QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4

QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4 DATASHEET - REV A QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4 #01 Overview QFPQL010400D is a high performance QSFP+ transceiver module for 40 Gigabit Ethernet data links

More information

SAN Distance Extension Solutions

SAN Distance Extension Solutions SN Distance Extension Solutions Company Introduction SmartOptics designs and markets all types of fibre optical Product portfolio: transmission products. Headquarted in Oslo, Norway, we serve Storage,

More information

Product Overview. Send documentation comments to CHAPTER

Product Overview. Send documentation comments to CHAPTER Send documentation comments to mdsfeedback-doc@cisco.com CHAPTER 1 The Cisco MDS 9100 Series Multilayer Fabric Switches provide an intelligent, cost-effective, and small-profile switching platform for

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Technical Description. MICROSENS MSP 1000 Platform xwdm system

Technical Description. MICROSENS MSP 1000 Platform xwdm system Technical Description MICROSENS MSP 1000 Platform xwdm system MICROSENS GmbH & Co. KG - Kueferstr. 16-59067 Hamm - Tel. +49 2381/9452-0 - www.microsens.com Technical Description MSP 1000 Platform Page

More information

GEVISTA. CWDM Pluggable OC-48 SFP Transceiver. Description

GEVISTA. CWDM Pluggable OC-48 SFP Transceiver. Description CWDM Pluggable OC-48 SFP Transceiver Description The CWDM-OC48-xx-80 is specifically designed for the high performance integrated duplex data transmission over single mode optical fiber. This transceiver

More information

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL DVBus 8050-16, 8050-24 and 8050-32 Multiplexer and demultiplexer assemblies for 16-32 video channels USER MANUAL 1. Description DVBus 8050 systems transmit 10-bit digitized video signals over one optical

More information

Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are:

Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are: E Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are: Native support for all SAN protocols including ESCON, Fibre Channel and Gigabit

More information

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A.

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH. Product Brochure. Copyright: Valiant Communications Limited U.K. INDIA U.S.A. V C ALIANT OMMUNICATIONS VCL-Gigabit Ethernet over SDH ( Gigabit Ethernet over STM-1) Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN United

More information

OPCOM600 series CWDM/DWDM System

OPCOM600 series CWDM/DWDM System OPCOM600 CWDM/DWDM System OPCOM600 product family is a cost-efficient and exceptionally flexibly solution for optimizing the utilization of existing fiber optics. This family is capable of operating on

More information

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure

V C ALIANT OMMUNICATIONS. VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure V C ALIANT OMMUNICATIONS VCL-Gigabit Ethernet over SDH (GigE) ( Gigabit Ethernet over STM- 4) Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3

More information

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway Cisco DCM Series D9901 Digital Content Manager IP Video Gateway Today s video contribution networks are evolving rapidly with the dual drivers of increased demand, for high-definition TV, and a need for

More information

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION PRODUCT SPECIFICATION P/N Description 10Gbps CWDM XFP 40km Transceiver Version A0 Issue Date 2015.06.07 Prepared By Checked By Approved By Jason Qi Wenshan Yang Nan Wang 10Gbps CWDM 40km XFP Transceiver

More information

RC702-FX Ethernet over SDH User Manual

RC702-FX Ethernet over SDH User Manual RC702-FX Ethernet over SDH User Manual Raisecom Technology Co., Ltd 1. Caution Please carefully read the following precautions before installing and deploying RC702-FX equipment, and operate strictly according

More information

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX Entry Line Fast Ethernet Switch Fast Ethernet Switch for Industrial Use Page 2/11 Table of Contents General... 3 Benefits... 3 Front

More information

PTC-101 Quick Installation Guide

PTC-101 Quick Installation Guide PTC-101 Quick Installation Guide Moxa Industrial Media Converter Edition 5.1, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high-order legacy traffic (TDM) over SDH/SONET networks Up to three E3 or T3 data channels multiplexed using a single hot-swappable

More information

S Optical Networks Course Lecture 7: Optical Network Design

S Optical Networks Course Lecture 7: Optical Network Design S-72.3340 Optical Networks Course Lecture 7: Optical Network Design Edward Mutafungwa Communications Laboratory, Helsinki University of Technology, P. O. Box 2300, FIN-02015 TKK, Finland Tel: +358 9 451

More information

Company Introduction. SmartOptics products now make optical networking, especially 4G, 8G and 10G connectivity, simple and affordable.

Company Introduction. SmartOptics products now make optical networking, especially 4G, 8G and 10G connectivity, simple and affordable. ctive SN WDM Distance Networking Extension Solutions Company Introduction SmartOptics is the only external transceiver vendor to be Product portfolio: approved and accepted in all latest rocade FC switches.

More information

IBM expands multiprotocol storage offerings with new products from Cisco Systems

IBM expands multiprotocol storage offerings with new products from Cisco Systems Hardware Announcement July 15, 2003 IBM expands multiprotocol storage offerings with new products from Cisco Systems Overview The Cisco MDS 9000 family is designed for investment protection, flexibility,

More information

SHFP-2G-B Gb/s BiDi SFP Transceiver Hot Pluggable, Simplex LC/SC, +3.3V, Single mode, 20km, 0~70 C 1310/1550nm or 1310/1490nm DFB/PIN

SHFP-2G-B Gb/s BiDi SFP Transceiver Hot Pluggable, Simplex LC/SC, +3.3V, Single mode, 20km, 0~70 C 1310/1550nm or 1310/1490nm DFB/PIN SHFP-2G-B20 2.5Gb/s BiDi SFP Transceiver Hot Pluggable, Simplex LC/SC, +3.3V, Single mode, 20km, 0~70 C 1310/1550nm or 1310/1490nm DFB/PIN SHFP-2G-B20 high performance, cost-effective 2.5G BiDi SFP transceiver

More information

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge

More information

Industrial Switches Industrial Switches

Industrial Switches Industrial Switches Industrial Switches Industrial Switches Copper cables Fiber optic cable Ring redundancy Industrial Switches Contents 23 General Product Information 2 Interfaces and Configurations 2 Application and Installation

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K.

V C ALIANT OMMUNICATIONS. VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure. Copyright: Valiant Communications Limited U.K. V C ALIANT OMMUNICATIONS VCL-Ethernet over SDH (Ethernet over STM-1) Product Brochure U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328 Uxbridge Road, London W3 9QN United Kingdom E-mail:

More information

Alcatel 1696 Metro Span. Metropolitan DWDM System

Alcatel 1696 Metro Span. Metropolitan DWDM System Alcatel 1696 Metro Span Metropolitan DWDM System In metropolitan areas, the need for higher bandwidth and valueadded services is becoming increasingly critical. Service providers must find flexible and

More information

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers Data Sheet Optimux-108, Optimux-106 Fiber Multiplexers, Transmit Any Traffic over Fiber Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link Various fiber interfaces: multimode,

More information

SFP LC 5G SMF DWDM Transmitter. Features. Applications APPLIED OPTOELECTRONICS, INC. A5ILZDxxSDOA0759

SFP LC 5G SMF DWDM Transmitter. Features. Applications APPLIED OPTOELECTRONICS, INC. A5ILZDxxSDOA0759 APPLIED OPTOELECTRONICS, I. Features Applications 5G Applications XAUI/OBSAI/CPRI (3.125G) Fiber Channel 3xFC (3.1875G) SONET OC48 / SDH STM16 (2.488Gbps) Gigabit Ethernet / 1X/2X Fiber Channel SFP Type

More information

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer Voice POTS Fiber Multiplexer NEW FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer The FOM-FXO32/FXS32 are a 1U, 19 Rack mountable voice transmission fiber multiplexers that transmits up

More information

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches Product Overview The Cisco Catalyst 2950 Series of fixed configuration, wire-speed Fast Ethernet desktop switches delivers premium

More information

QFPQL002400D QSFP+ Dual Fibre CWDM ITU CWDM / 2km / 40 Gigabit Ethernet / IR-4

QFPQL002400D QSFP+ Dual Fibre CWDM ITU CWDM / 2km / 40 Gigabit Ethernet / IR-4 QFPQL002400D QSFP+ Dual Fibre CWDM ITU CWDM / 2km / 40 Gigabit Ethernet / IR-4 For your product safety, please read the following information carefully before any manipulation of the transceiver: ESD This

More information

Parameter Symbol Min. Typical Max. Unit Storage Temperature T S C Supply Voltage V CC T, R V Relative Humidity RH 0 85 %

Parameter Symbol Min. Typical Max. Unit Storage Temperature T S C Supply Voltage V CC T, R V Relative Humidity RH 0 85 % Features: Supports 8.5Gb/s to 11.3Gb/s bit rates Hot-pluggable SFP+ footprint Single LC for Bi-directional Transmission Maximum link length of 40km Built-in 1270 WDM Uncooled 1270nm DFB Laser. Power dissipation

More information

STRATOS LIGHTWAVE Active Optical Products Guide

STRATOS LIGHTWAVE Active Optical Products Guide STRATOS LIGHTWAVE Active Optical Products Guide Innovative Customer Solutions Military & Aerospace Modules LOW RIDER TRANSCEIVERS Excellent thermal characteristics Exceptional EMI/RFI performance High

More information

iaccess Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series

iaccess Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series iaccess TM Multi-Service Platform-DM In Band Managed Multi-Service Platform-FRM220 Series Mobile Fronthaul & Backhaul for 4G LTE 10G Ethernet for Data Center Solution Carrier Ethernet (NID & EDD) CWDM

More information

DWDM Cards. 6.1 DWDM Card Overview CHAPTER

DWDM Cards. 6.1 DWDM Card Overview CHAPTER CHAPTER 6 This chapter describes Cisco ONS 15454 dense wavelength-division multiplexing (DWDM) card features and functions. For installation and card turn-up procedures, refer to the Cisco ONS 15454 Procedure

More information

Introduction. Coarse Wave Division Multiplexing Solution

Introduction. Coarse Wave Division Multiplexing Solution Coarse Wave Division Multiplexing Solution Introduction World Wide Packets LightningEdge Coarse Wave Division Multiplexing (CWDM) solution presents service providers with a way to selectively increase

More information

Specifications Connectors. Chassis backplane consists of passive components. Single or optional redundant power supplies

Specifications Connectors. Chassis backplane consists of passive components. Single or optional redundant power supplies 2U Managed Platform - FRM220 In-band Managed Multi-service Platform FRM220 The FRM220 is a 2U high 19" Rack, 20 slot modular media converter rack. It provides an economic solution in high density fiber

More information

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications. Where to buy > Product page > Data Sheet, L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Combination of T1 and E1 channels Transmission over coax or fiber optic cable Range

More information