Comprehensive Feeder Protection FCOMP FEEDER CONTROL METERING PROTECTION RELAY

Size: px
Start display at page:

Download "Comprehensive Feeder Protection FCOMP FEEDER CONTROL METERING PROTECTION RELAY"

Transcription

1 Comprehensive Feeder Protection FCOMP FEEDER CONTROL METERING PROTECTION RELAY

2 Larsen & Toubro (L&T) is a technology-driven company that infuses engineering with imagination. The Electrical & Automation Group of L&T offers a wide range of advanced solutions through its state-of-the-art products backed by world-class in-house capabilities in technology development customer support. For complete feeder protection of air, vacuum or gas-insulated circuit breaker operated feeders in medium and low voltage switchgear assemblies, L&T offers a comprehensive Feeder Control Metering Protection Relay the FCOMP. ABOUT FCOMP The FCOMP combines the ruggedness of conventional feeder protection and the versatility of advanced feeder protection features, annunciations and metering in MV and LV switchgear assemblies into one single, simple-to-configure, communicating module with a large color display. It is scalable, modular and of the right size to cater to your varied feeder protection requirements. To make it suitable for the often dusty and corrosive environs of substations (as in process industries and petrochemical complexes), the FCOMP has a conformal coating on its hardware. User-friendly options and features Universal auxiliary power supply of VAC / VDC o o Operating temperature range of -20 C to 85 C Current-based metering and protection with optional scalability for voltage-based metering and protection built into a single unit Reduced and simplified wiring(especially in auto bus transfer schemes) and reduced dependence on auxiliary components in different schematics through varied DI/DO combinations Facilitation of reconfiguration of auto bus transfer conditions /interlocks, configuration of load shedding and load-sharing, reverse interlocking, conditions for tripping and closing of the circuit breaker, annunciation and status exchange. Six configurable pushbuttons for control and 2 configurable LEDs for indication Advanced substation communication protocol options, viz.: Modbus RTU, Profibus, IEC Modbus TCP/IP, IEC 6850 Scaled up substation communication network architectures with redundancy for IED communications through dual Rj45 and FO(SC/ST) ports for ethernet communication and dual RS485 ports for serial communication Easy connection with a computer through the default USB 2.0 port Easy relay configuration through the indigenous interface software, COMPfigurator, which is provided with configuration settings, communication settings, protection settings, gate logic, latches, timers, event recording and disturbance recording. It allows for online and offline creation of settings files for uploading and downloading to the relay. 4 setting groups, multiple stages in each protection settings and user selectable option on protection source between Fundamental Metering and RMS metering.

3

4 PROTECTION FUNCTIONS PROTECTION FUNCTION ANSI CODE VARIABLE RANGE Instantaneous Phase Over Current Instantaneous Neutral / Ground OC Negative-Sequence Instantaneous OC Timed Phase Over Current Timed Neutral / Ground OC Negative-Sequence Timed OC Thermal Overload Under Current Restricted Earth Fault + Sensitive Ground Fault Auto Reclosure & Lockout Breaker Failure Trip Circuit Supervision Phase Sequence Monitoring Voltage * Positive Sequence voltage * Negative Sequence Over voltage * Frequency * Frequency Gradient * Directional Phase and Neutral/Ground OC ** Directional Phase and Neutral / Ground Timed OC ** Power * Power Factor * Voltage Restraint for Phase Timed OC * VT Fuse Failure * Synchro Check ** 50P 50N, 50G 50Q 5P 5N, 5G 5Q 49 37P 64 50SG, 5SG 79, 86 50BF 74TC 47 27P, 27X 59P, 59X. 59N 47 O+, 47 U+ 47 O- 8U, 8O 8R 67P, 67N, 67G - IOC 67P,67N,67G - TOC 32, 32R 55 5V Accuracy Time Accuracy K Factor S Max no. of shots Dead Time Mode Ph current supervision Alarm Delay Three pole initiate - Direction Characteristic Angle Direction Characteristic Angle A CT 5A CT Function - Voltage difference Angle difference Frequency difference In Sec + 2% of setting + 30ms In IEC, IEEE Curves 0. to 4.0 In Sec In Sec 0.02 In 0 Sec A Sec Sec 3 pole, Pole In Sec On, Off Sec Vn Sec Vn Sec Vn Sec Hz 0-00 Sec Hz/Sec 0 00 Sec Forward, Reverse In Sec Deg (for 67P) Deg (for 67N/67G) Forward, Reverse In Sec Deg (for 67P) Deg (for 67N/67G) VAR, KW 6500 VAR, KW Sec On, Off V Hz + Note: Optional *Basic voltage based protections are enabled upon selection of the FCOMP with voltage card. **Advanced voltage base protections are enabled when options are so chosen at the time of ordering.

5 PROTECTION BLOCK BUS 3 27P* 59P* 59G* 59Q* 8O* 8U* LINE 67IP* 67TP* 32* 32R* 60* 55* 8R* 5V* 3 50P 50G 50Q 5P 5G 5Q 37P N 5N 67IN* 67IG* 67TN* 67TG* 27S* * 50SG* 5SG* 59S* BREAKER FEEDR *Optional ADVANCED FEATURES Blocked Over Current Selective Over Current Cold Load nd 2 harmonic Blocking CT Supervision Zone Selective Interlock Breaker Arcing Current Breaker Re-Strike Breaker Contact Wear Monitoring Auto recloser Load Shedding & Restoration Trip / Close Logic COMMUNICATION OPTIONS Protocols Modbus RTU Modbus TCPIP IEC 6850 IEC Profibus Media Serial Ethernet on copper Ethernet on Fiber Ports RS 232 -USB (Front) RS 485 (CPU Card) Dual RJ 45 (CPU Card) Single FO (CPU Card) Dual RS 485 (Communication Card)* Dual RJ 45 (Communication Card)* Dual FO SC / ST (Communication Card)* *Optional

6 METERING & MONITORING METERING SPECIFICATIONS Current No. of CTs: 5 (R,Y,B,REF,N/SEF) Phase and Neutral CT (R,Y,B,N) In (Nominal current)a Rated Range : A Continuous Rating : 4 A Second Thermal : 00 A Rated Frequency : 50/60 ± 5 Hz In (Nominal current)5a Rated Range : A Continuous Rating : 20 A Second Thermal : 500 A Rated Frequency : 50/60 ±5 Hz REF CT In (Nominal current) A Rated Range : A Continuous Rating : A Second Thermal : 2 A Rated Frequency : 50/60 ± 5 Hz In (Nominal current)5a Rated Range : 0. 6 A Continuous Rating : 5 A Second Thermal : 0 A Rated Frequency : 50/60 ±5 Hz SEF CT Rated Range : 2.5mA.6 A Continuous Rating : A Second Thermal : 0 A Rated Frequency : 50/60 ±5 Hz Measurement Range : 0 to 20 In Accuracy of reading : ± 0.25% REF Current : ± % Ig using CBCT : % Instantaneous demand current : Yes Max/Min demand current : Yes Avg of all 3 phase RMS currents : Yes Voltage Rated Operating voltage : Vac Rated Continuous Voltage : 300 Vac 0 Second Thermal : 600 Vac Rated Frequency : 50/60 ±5 Hz Type of measurement Phase to phase RMS, Max and Average Phase to N - RMS, Max and Average Measurement Range : 0. 2 Vn Accuracy : 0.5% of reading from 0. Vn to.5 Vn Max/Min voltage : Yes Avg of all 3-phase RMS voltages : Yes Power / Energy P.F. Harmonics Phase wise & total Active, Re-active & Apparent Power / Energy Accuracy : % Phase wise & total Range : - to + Resolution : 0.0 Accuracy : ± 2% of Reading Harmonics measurement up to: 25th component Current & Voltage Harmonics THD measurement Frequency Range : 40 to 70 Hz Accuracy : ± 0.0Hz Temp Measurement Range : 0 to +250 C RTD protection (Optional PTC available) Sequence Voltage and Current (Positive, Negative and Zero Sequence Components) - Accuracy : % MONITORING Oscillography Event Record Hour Meter SPECIFICATIONS Oscillographic Sampling Rate - 64 samples per cycle Maximum records: 64 (User-configurable data) AC input channels Protection element state Digital input and output state Pre Trigger & Post Trigger Duration programmable : 64 Samples x 6 Cycles x 6 Channels x 2 Byte 024-Event history Records operating hours of the equipment in operation Records number of hours since last auxiliary power off This Document and Design are the property of Larsen & Toubro Limited and must not be copied or lent without their permission in writing.

7 CONFIGURATION Basic Unit Optional Cards Universal power supply ( VAC / VDC) Processor card 2DI + 2 DO (Heavy duty) Communication card IO card Slot IO card Slot 2 IO card Slot 3 Serial port Modbus RTU Dual Ethernet port Modbus TCPIP (Fiber or Copper) Dual Ethernet port IEC 6850 (Fiber or Copper) Dual Serial port Modbus RTU / Profibus / IEC Voltage + Sync Voltage Card Basic Unit CT card: 3Ph + REF + Neu / SEF IO OPTIONS Input voltage option in DI: 24 VDC 0 VAC/VDC or 230 VAC/VDC (Software Selectable) Output contact rating of DO: Form A Contact Rating: 8A at 250VAC and 5A at 30VDC, 0.2A at 00VDC Maximum operating rating (AC): 2000VA Form C Contact Rating: 8A at 250VAC and 5A at 30VDC, 0.3A at 300VDC Maximum operating rating (AC): 2000VA Input Option in AI: (+) 0 V or (+) 20mA input 2-wire PT00 input, C Digital Input Output Card variants: 7 Digital input + 2 Digital output (Form C) 4 Digital input + 2 Digital output (Form C) + 3 Digital output (Form A) 9 Digital input 6 Digital input + 2 Digital output (Form C) + Digital Output (Form A) 6 Digital output (FormC) + Digital output (Form A) Analog Input Output Card variants: 3 Analog input + 2 Analog output + 5 DI (230/0 V AC/DC) 5 Channel RTD + 5 DI (230/0 V AC/DC) 0 Channel RTD

8 INTERFACE SOFTWARE The COMPfigurator is a specialized software designed to interface with the FCOMP. FCOMP parameters can be configured, metered, monitored through the COMPfigurator. The FCOMP settings file can be generated by the COMPfigurator by either of these methods: Online mode (FCOMP-powered on and connected with the COMPfigurator ) Offline mode (FCOMP disconnected). The settings file is generated with FCOMP disconnected and downloaded later onto it. The settings file comprises the following configurations which can be modified as per user requirement: General settings (CT ratio, PT ratio, sync input, DIO, AIO, phase rotation, nominal freq, etc.) Protection settings (All current and voltage-based protections) Pushbuttons LEDs Digital output, analog output Event record Pre- and post-fault settings of disturbance record Single line diagram The COMPfigurator can also be used for real time / online metering of: Analog Data: Current, Voltage, Frequency, Power, Power factor Digital Data: Digital input status, digital output status, electrical fault status The COMPfigurator can also be used to monitor and record parameters like event history, sequence of events (024), disturbance record (64 samples / cycle x 6 channels) and hour meter. The COMPfigurator has an option to save the setpoint files file and event records, as required, with password protection. This Document and Design are the property of Larsen & Toubro Limited and must not be copied or lent without their permission in writing.

9 COMPlogic The COMPlogic is part of the COMPfigurator software. It is used to programme the FCOMP to tailor the control and operation of the circuit breaker. The COMPlogic includes: Arithmetic operation (+, -, >, <, =) Logic Gate (AND, OR, NOT) Timer (Pick up, Drop out) Latch 52 lines for control equations Note: For details of sample control equations to implement schematics, refer to the FCOMP operation manual.

10 USER INTERFACE Rear Panel DCS HMI SCADA PC Interface Modbus RTU RS- 485 Speed: bps Dual port Modbus TCP/IP 0 / 00 Mbps Copper / Fiber Same IP Address Modbus RTU RS- 485 Speed: bps IEC / 00 Mbps Copper / Fibre Separate IP Address Front Panel PC Interface USB port Modbus RTU Speed: bps This Document and Design are the property of Larsen & Toubro Limited and must not be copied or lent without their permission in writing.

11 DIMENSIONAL DETAILS 43mm 252mm 30mm 60mm 285mm Door Cutout 256mm 268mm COMPLIANCE Tests Enclosure Protection : IEC 60529:200 IP65 enclosed in panel IP20 for terminals Vibration : IEC :995 IEC :988, Class IEC :993, Class 2 Shock : IEC :988, Class Cold : IEC :990 Damp Heat : IEC :200 Steady State Temperature Cyclic : IEC :980 Test (with Humidity) Dielectric Strength and Impulse Test Dielectric (HIPOT) : IEC :2000 IEEE C Impulse : IEC :2000 RFI and Interference Test ESD Immunity : IEC :200 Radiated RF Immunity : IEC :2002 EFT Immunity : IEC :200 Surge Immunity : IEC :200 Surge Withstand : IEC :988 Capability Immunity Conducted RF Immunity : IEC :2003 Magnetic Field Immunity : IEC :200 Conducted Emissions : EN 550:998, CISPR 22 Radiated Emissions : EN 550:998, CISPR 22

12 TYPICAL WIRING DIAGRAM R Y BUS R Y B CIRCUIT BREAKER B FUSE VT CONNECTION SYNCHRONISM CHECK LINE CT CONNECTION A03 A02 A0 AUXILIARY SUPPLY Z0 Z02 P/+ N/- G R Y0 R Y02 Y Y03 B Y04 N Y05 Vs Ns Y06 DO7 DO6 DO Z03 Z04 Y DO CBCT CLASS PX CT METROSIL SEF CONNECTION REF CONNECTION STABILISING RESISTOR Z05 Z06 Z07 Z08 Z09 Z0 B SEF / N REF DI9 DI8 DI7 DI6 DI5 DI4 DI3 DI2 DI FCOMP FRONT PORT USB FEEDER CONTROL METERING PROTECTION DO3 DO2 DO DO3 DO2 DO DI6 DI5 DI4 DI3 DI2 DI DI B0 B02 PC INTERFACE DI B03 B PORT B MODBUS RTU PORT B2 MODBUS TCP/IP +TX -TX +RX -RX SHLD A PORT C MODBUS RTU +TX -TX +RX -RX SHLD PORT C2 MODBUS RTU PORT C3 IEC 6850 DO2 B05 B06 +TX -TX +RX -RX SHLD A B DO B07 B08 This Document and Design are the property of Larsen & Toubro Limited and must not be copied or lent without their permission in writing.

13 COMMUNICATION ARCHITECTURE Redundancy Module To Profibus master Primary device on serial or FO link To Profibus master Secondary device on serial or FO link Profibus cable Terminating resistor IED IED 2 IED n PROFIBUS DAISY-CHAIN COMMUNICATION CONNECTION DUAL DAISY CHAIN DAISY CHAIN To Modbus RTU master device STP cable STP cable To Modbus RTU master device To Modbus RTU master device STP cable IED IED 2 IED n MODBUS RTU DUAL DAISY-CHAIN REDUNDANT COMMUNICATION CONNECTION IED IED 2 IED n MODBUS RTU DAISY-CHAIN REDUNDANT COMMUNICATION CONNECTION To Modbus TCP/IP master device To Modbus TCP/IP master device To IEC 6850 master device To IEC 6850 master device ETHERNET SWITCH ETHERNET SWITCH ETHERNET SWITCH CAT 5e cable SMFO cable SMFO cable IED IED 2 IED n MODBUS TCP/IP DAISY-CHAIN COMMUNICATION CONNECTION IED IED 2 IED n IEC6850 STAR REDUNDANT COMMUNICATION CONNECTION

14 COMPLETE SUBSTATION INTEGRATION SUBSTATION HMI Laser Printer OWS EWS RDBS Alarm Viewer Printer MCR LAN MCR Modbus TCP/IP Network IPCS LAN Substation HMI L&T DC Redundant Pair GPS Server for Time Synchronization L&T Gateway Redundant Pair IPCS Modbus TCP/IP Network IEC6850 Network ES- Modbus RTU to TCP Converter ES-2 ES-3 MCOMP on Modbus TCP/IP MCOMP on Modbus RTU LV / MV SWGR FCOMP on IEC6850

15 ORDER CODE FCOMP PART NO SELECTION OPTIONS FCOMP PART NO PSU CPU COMM IO IO2 IO3 VT CT FCOMP A BXXX X XXX XX X 2XX X 3XX X XX C FCOMPABXXXXXXXXXX2XXX3XXXXXC Auxiliary Input A / 60 Hz, VDC Basic Processor Card Communication Card (Optional) IO Slot (Optional) Voltage Input (Optional) CT Input XXX ETH FSC FST X M P XXX ETH FSC FST XX D D2 A R X XX V V2 Rs485 for Modbus RTU communication interface (Basic Included) 2 Digital input (230/0 VAC / VDC) 2 Digital output (Basic Included) No Modbus TCP/IP Fiber Optic communication interface; Single port with ST connector (Modbus TCP/IP) No Card Rs485 for Modbus communication interface, bps Rs485 for Profibus communication interface No card Ethernet communication interface; Dual RJ-45 port Fiber Optic communication interface; Dual port with SC connector Fiber Optic communication interface; Dual port with ST connector No Card 24 VAC / VDC Voltage input 230/0 VAC / VDC Voltage input 7 Digital input + 2 Digital output (Form C) 4 Digital input + 2 Digital output (Form C) + 3 Digital output (Form A) 9 Digital input 6 Digital input + 2 Digital output (Form C) + Digital Output (Form A) 6 Digital output (Form C) + Digital output (Form A) Analog Input Output Card 3 Analog input + 2 Analog output + 5 DI (230/0 V AC/DC) RTD Input Card 5 Channel RTD (2 wire PT00 i/p, deg C) + 5 DI (230/0 V AC/DC) 0 Channel RTD (2 wire PT00 i/p, deg C) No Card 3 Phase Voltage input with Vsync option; 0 32 V AC 3 Phase Voltage input with Vsync option; V AC C 5 AC Current input, Amp phase (R,Y,B) and Amp neutral (N) + REF C2 5 AC Current input, 5 Amp phase (R,Y,B) and 5 Amp neutral (N) + REF C3 5 AC Current input, Amp phase (R,Y,B), Amp CBCT + REF C4 5 AC Current input, 5 Amp phase (R,Y,B), 5 Amp CBCT + REF

16 Sales Offices - India Sales Offices - International Chennai L&T Construction Campus TC- Building, II Floor Mount-Poonamallee Road Manapakkam Chennai Tel: Fax: ese-chn@lntebg.com Hyderabad Post Bag2,Vasantha Chambers 2 floor, , Fateh Maidan Road Hyderabad Tel: Fax: ese-hyd@lntebg.com Kolkata Post Bag 69 3-B, Shakespeare Sarani Kolkata Tel: /2558 Fax: /025 ese-kol@lntebg.com Mumbai Gate no. 7, North Wing, Level 2 Saki-Vihar Road, Powai Mumbai Tel: Fax: ese-mum@lntebg.com New Delhi Post Bag , Shivaji Marg New Delhi 0 05 Tel: /9942 Fax: ese-del@lntebg.com Vadodara Radhadaya Complex, J.P. Road Vadodara Tel: /38 Fax: ese-vad@lntebg.com India Gate No.7, Saki-Vihar Road North Wing, Level Mumbai Tel: Fax: ese-intl@lntebg.com Saudi Arabia L&T Electricals Saudi Arabia Company Limited - L. L. C MH-4, Plot: 7+9 2nd Industrial Area, Dammam Kingdom of Saudi Arabia Tel: Fax: ltesa@lntebg.com UAE 2202, 22nd floor Green Emirates Tower - A Electra Street, P.O. Box Abu Dhabi, UAE Tel: Fax: ese-uae@lntebg.com Oman P.O. Box 598, Ruwi, Postal Code-2 Sultanate of Oman Tel: Mob: ese-oman@lntebg.com Malaysia TAMCO SWITCHGEAR (MALAYSIA) SDN BHD Sub Lot 24, Lot 6505, Jalan Keluli PO Box 200, Bukit Raja Industrial Area Section ShahAlam, Selangor, Malaysia Tel: Fax: tamco@tamco.com.my Australia TAMCO Electrical Industries Australia Pty Ltd 3 Kitchen Road, Dandenong 375 Melbourne, Victoria, Australia Tel: Fax: sales@tamcoaustralia.com.au Indonesia PT. TAMCO Indonesia F-36, Jalan Jababeka Raya Jababeka Industrial Estate Cikarang Utara, Bekasi,7530, Indonesia Tel: Fax: inquiries@tamco.co.id Kenya A, 3rd Floor Westlands Business Park 04, Chiromo Lane Westlands, P.O. Box no Nairobi, Kenya Tel: ese-kenya@lntebg.com Qatar 2 & 3rd Floor, Building No. 209 Zone 42, Street 230 Najma Intersection, Opp: Doha Cinema, a C-Ring Road, P.O. Box No Doha, Qatar Tel: Fax: ese-qatar@lntebg.com FCA8.05.3/PRD Larsen & Toubro Limited, Electrical Systems & Equipment Gate No. 7, North Wing, Level, Saki-Vihar Road, Powai, Mumbai , INDIA Tel: / 2857 Fax: ese-cmt@lntebg.com Registered Office: L&T House, N. M. Marg Ballard Estate Mumbai , INDIA The information contained herein is correct at the time of publication. This information may be subject to change without notice.

Bus Bar Protection Relay B-PRO 4000

Bus Bar Protection Relay B-PRO 4000 Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation

More information

Protection relays.

Protection relays. Protection relays www.vamp.fi Vamp Ltd Vamp Ltd, with a strong experience of designing devices, is an independent supplier of relays and monitoring equipment. The company has an established reputation

More information

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection

More information

Transformer Protection Relay

Transformer Protection Relay Transformer Protection Relay T-PRO Product Overview The IEC 61850 station bus embedded T-PRO relay provides complete three-phase multi-winding transformer protection and overload protection, DFR-quality

More information

MINER-S Station Controller

MINER-S Station Controller MINER-S Station Controller Substation Automation MINER-S Station Controller The MINER-S Station Controller is a SCADA enabled fixed point remote terminal unit (RTU) with a data concentrator, event reporter,

More information

For Transmission, Distribution and Machinery protection.

For Transmission, Distribution and Machinery protection. Founded in 1953, Microelettrica Scientifica has developed a wide range of products, divided into three main lines: For Transmission, Distribution and Machinery protection. A-Line Electronic analogic. M-Line

More information

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL MICROPROCESSOR PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL MICROELETTRICA SCIENTIFICA MANUFACTURES A COMPLETE RANGE OF

More information

Scout-S Station Controller

Scout-S Station Controller Scout-S Station Controller Substation Automation Scout-S Station Controller The Scout-S Station Controller is a SCADA enabled remote terminal unit (RTU) with a data concentrator, event reporter, and built-in

More information

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs .3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton

More information

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay Bus Differential and Breaker Failure Relay A Powerful Solution for Busbar Differential Protection Features and Benefits Select the for the differential protection of busbar systems with up to 18 terminals.

More information

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators NewCode Comprehensive Motor Protection and Control Relay Relay Field Input and Output LEDs LED Fault Indicators Configurable Memory Module on a T-Bus IrDA and USB Connectors Profibus Address Indicator

More information

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy

Reyrolle Protection Devices. 7SG117 Argus 7 Synchronising Relay. Answers for energy Reyrolle Protection Devices 7SG117 Argus 7 Synchronising Relay Answers for energy 7SG117 Argus 7 Synchronising Relay Fig 1. Independent check & system synchronising settings Adjustable slip frequency,

More information

PMC 530 Series Advanced Multifunction Meter

PMC 530 Series Advanced Multifunction Meter IEC 62053 22 Class 0.5S WF Capture @ 128 samples/cycle WF and Data Recording Harmonics & Transient Monitoring I residual Monitoring Setpoint Alarms, SOE Log RS 485 and I/O Capabilities Large, Bright, Backlit

More information

Feeder/ Motor Protection Relay VAMP 40

Feeder/ Motor Protection Relay VAMP 40 Feeder/ Motor Protection Relay Feeder/motor protection relay Main characteristics Complete protection Comprehensive selection of protection functions for distribution network overhead line feeders, cable

More information

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead solutions Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage Overhead switching products Brochure Your outdoor overhead distribution

More information

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Recloser Controller for feeder protection and automation siemens.com/distribution-automation SIPROTEC 7SC80 Control Controller for feeder protection and automation siemens.com/distribution-automation SIPROTEC 7SC80 Control Designed for feeder automation applications This solution allows very fast

More information

LE ELECTRONICS Pvt. Ltd.

LE ELECTRONICS Pvt. Ltd. LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM

More information

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100% Operating range: 0.10 to 30 xin (step 0.01) 50P(2) Activation level 100% Deactivation level 95% Timer accuracy: 30 ms Operating range: 0.10 to 30 xin (step 0.01) 50N/G(2) Activation level 100% Deactivation

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

A low-cost, economical solution for distribution feeder protection

A low-cost, economical solution for distribution feeder protection SEL-351A Protection System A low-cost, economical solution for distribution feeder protection Achieve sensitive and secure fault detection using comprehensive protection functions. Track breaker status

More information

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485 Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, RS-485 Main Range of product Product or component type Relay application Device short name [Us] rated supply voltage Type of

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin

F650 - More than Feeder Protection & Control. GE Consumer & Industrial Multilin F650 - More than Feeder Protection & Control F650 Bay Controller A Comprehensive Protection and Control solution for Transmission and Distribution Networks 2 Introduction: What is the F650? Protection,

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. www.siemens.com/protection SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. designed for feeder automation applications This solution allows very fast fault detection

More information

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy Reyrolle Protection Devices 7SG118 Argus 8 Voltage & Frequency Relay Answers for energy 7SG118 Argus 8 Voltage and Frequency Relay Data Storage and Communication Serial communications conform to IEC60870-5-103

More information

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

Designed For Reliability Manufactured To Last

Designed For Reliability Manufactured To Last 512/1024 samples/cycle IEC 62053-22 Class 0.2S Compliant IEC 61000-4-30 Class A Sag/Swell, Transient and Flicker Comprehensive Data Recording PQDIF & COMTRADE Compatible 5.7 Color LCD Display @ 640x480

More information

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet PowerLogic power-monitoring units power meter Technical data sheet 2011 Basic energy meters Functions and characteristics PE86261 PE86260 PowerLogic PM1000 power meter. The PowerLogic power meters are

More information

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box INTRODUCTION The PL-50 MO units are available in the next mechanical version: The PL-50 MO and PM-250 families represent the different solutions that Team Arteche offers for motor protection. Both families

More information

InteliPro. Protection Relay for Parallel Applications. Technical Specification

InteliPro. Protection Relay for Parallel Applications. Technical Specification InteliPro Protection Relay for Parallel Applications Product description InteliPro is a highly flexible interconnection/mains decoupling protective relay with extensive protective functions. It meets the

More information

Providing the missing piece in your Condition Based Monitoring platform

Providing the missing piece in your Condition Based Monitoring platform QUALITROL Transformer Monitoring System Providing the missing piece in your Condition Based Monitoring platform Modular design; full customization of monitoring parameters to meet specification Reduce

More information

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values CT/VT Interface 560CVT10 The fault current is measured up to 20 times nominal current. Therefore the current inputs withstand 50 times nominal current for 1 s. The CT/VT interface is equipped with one

More information

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering. MIN II Key Benefits Reduce troubleshooting and maintenance cost - event recording, and analogy/digital oscillography Design flexibility - Easy to use programming logic Access to information - Modbus RTU

More information

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45 Characteristics Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: 48-230V, DI: 220-230V, 2 x RJ-45 Main Range of product Product or component type Relay application Configuration type (Cortec) [Us] rated supply voltage

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

FP-5000 Feeder Protection

FP-5000 Feeder Protection Effective: April 2001 Page 1 New Information FP-00 Feeder Protection Contents Description Page FP-00 Description......... 2 Application Description...... 2 Features, Functions and Benefits..............

More information

MINER-S Station Controller. Substation Automation

MINER-S Station Controller. Substation Automation Substation Automation MINER-S Station Controller incorporates traditional RTU functions with new technology in a compact design MINER-S Station Controller combines the functions of a traditional RTU with

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators. SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering

More information

extending the boundaries of technology evolution of proven technology FEATURES

extending the boundaries of technology evolution of proven technology FEATURES extending the boundaries of technology evolution of proven technology FEATURES IEC 61850 compliant Advanced AC capabilities with comprehensive fault detection Integrated protection functions Disturbance

More information

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network SIL-G Feeder & Generator Protection Relay RC FLSH Main characteristics The SIL-G is a relay for primary distribution which can protect a feeder by means of current and voltage functions. It is also provided

More information

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay IE ON RESET.5 X1 t IE X1.6%.2.4.8 1.6 X1.1s.2.4.8 1.6 X2 OFF ON S1 S2 IRI1-ES IRI1-ES C&S Electric Limited (Protection & Control Division) Contents

More information

GE Multilin 350 Feeder Protection Relay Specifications

GE Multilin 350 Feeder Protection Relay Specifications GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following

More information

Intelligent Power Factor Controller with Automatic set-up. etacon Series. Automatic Power Factor Controller

Intelligent Power Factor Controller with Automatic set-up. etacon Series. Automatic Power Factor Controller Intelligent Power Factor Controller with Automatic set-up etacon Series Automatic Power Factor Controller Trouble-free Power Factor Correction is now at your fingertips, thanks to the etacon series of

More information

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL BE1-851E ENHANCED OVERCURRENT PROTECTION SYSTEM DEVICE FUNCTIONS 43 50 51 62 The BE1-851E is an enhanced overcurrent protection system based on the design of the BE1-851, a multifunction, numeric relay

More information

LM10 to MM200 Retrofit

LM10 to MM200 Retrofit Grid Solutions LM10 to MM200 Retrofit Replace old LM10 Motor Controller relays with the Multilin TM MM200 Motor Management System The LM10 Motor Controller (discontinued in 2013) has been replaced by new

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Advanced distribution feeder solution with integrated protection, monitoring, and control

Advanced distribution feeder solution with integrated protection, monitoring, and control Protection System Advanced distribution feeder solution with integrated protection, monitoring, and control Achieve sensitive and secure fault detection using comprehensive protection functions. Keep track

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

ENhanced TEChnology.   Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Using the Bitronics 70 Series to Improve Local Monitoring and Control

Using the Bitronics 70 Series to Improve Local Monitoring and Control Automate a Substation and Preserve the Electromechanical Relay Investment Part Two of Four Using the Bitronics 70 Series to Improve Local Monitoring and Control Paul Grabowski - Bitronics Senior Application

More information

GRD130 - FEATURES APPLICATION

GRD130 - FEATURES APPLICATION FEATURES Phase undervoltage protection with IDMTL or DTL. Phase overvoltage protection with IDMTL or DTL. Zero phase sequence overvoltage (neutral voltage displacement) protection with IDMTL/DTL. Negative

More information

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES Introduction The supply of electrical energy occupies an important position in the life of modern society. Operation of commerce, industry, transport,

More information

Protection relay for secondary distribution

Protection relay for secondary distribution Protection relay for secondary distribution Dual and Self powered Signalling with flag indicators High electromagnetic compatibility Events recorder and specific test menu Protection relay for secondary

More information

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES Multilin EPM 6010 BUILDING AUTOMATION POWER METER BACnet /IP Communications and Energy Measurement KEY BENEFITS Rapid integration into BACnet management systems High accuracy multifunction power meter,

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

Feeder Protection Relay REF 610. Product Guide

Feeder Protection Relay REF 610. Product Guide Product Guide Contents 1 Description.............................. 3 2 Protection functions....................... 3 3 Measurement............................ 4 4 Disturbance recorder......................

More information

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830 PC83 and PC830 series devices are designed to perform the relay protection functions and 6-154 kv networks automation, have different functionality

More information

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test: Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection Relays PHASE & RESIDUAL OVERCURRENT Protection Relays PHASE & RESIDUAL OVERCURRENT Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent

More information

Synchro-check relay. Application

Synchro-check relay. Application Issued: April 1999 Status: Updated Version: B/08.11.2001 Data subject to change without notice Features Two identical operation stages allowing the closing conditions of two separate circuit breakers to

More information

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser encapsulated with

More information

PGC 4000v2 POWER GENERATION CONTROLLER

PGC 4000v2 POWER GENERATION CONTROLLER PGC 4000v2 POWER GENERATION CONTROLLER THOMSON POWER SYSTEM PGC 4000v2 OFFERS THE FOLLOWING: Superior control & monitoring system for Thomson Power Systems advanced Series 2400 Switchgear (refer to separate

More information

BF

BF BE1-11i INTERTIE PROTECTION SYSTEM DEVICE FUNCTIONS The BE1-11i Intertie Protection System is a multifunction numeric relay providing the protection and control requirements outlined in IEEE 1547-2003

More information

EM6400 series Multi-Function meters

EM6400 series Multi-Function meters 6400 series Multi-Function meters 1 Digital display & Analog load bar indicators 2 Bright Red LED display 3 Global: CE, UL marks 4 Universal Demand Monitoring Quick and easy installation Turbo Key 6400

More information

POWER GRID AUTOMATION. Pág.. n. RMU Automation

POWER GRID AUTOMATION. Pág.. n. RMU Automation POWER GRID AUTOMATION RMU Automation Distribution Network Non-Controlled Secondary Distribution Systems Distribution Network RMU Automation - Levels RMU Automation - RTU / FRTU SMART CONTROLLER Monitoring

More information

PMC-630 Series Advanced Multifunction Meter

PMC-630 Series Advanced Multifunction Meter IEC 62053-22 Class 0.5S Compliant 2MB Log Memory Power Quality Monitoring Waveform Recording SOE Log Setpoint Alarms RS-485 and I/O Capabilities I residual Monitoring Large, Bright, Backlit LCD Display

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

DIRIS A-30 Multifunction power metering & monitoring device - PMD

DIRIS A-30 Multifunction power metering & monitoring device - PMD Single-circuit metering, measurement & analysis The solution for > Industry > Building > Infrastructures diris_986_a_us.psd Strong points Function The is a power metering and monitoring device that provides

More information

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Relion 605 series. Self-powered feeder protection REJ603 Product Guide Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1. Description... 3 2. Relay functions... 3 3. Protection functions... 4

More information

Communication Gateway COM 610. Product Guide

Communication Gateway COM 610. Product Guide Communication Gateway COM 610 Product Guide Issued: September 2004 Status: Updated Version: D/17.10.2006 Data subject to change without notice Features Protocol conversion gateway for substation automation:

More information

M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS

M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS M-6200A DIGITAL VOLTAGE REGULATOR CONTROL SUGGESTED SPECIFICATIONS Pole-Top/Pad Mount Digital Voltage Regulator Control, for metering, monitoring, and operational control for step-voltage Regulators shall

More information

////// SUBSTATIONS. Control command and local Scada

////// SUBSTATIONS. Control command and local Scada ////// SUBSTATIONS Control command and local GENERAL INFORMATION The solution provided by Sécheron for local control and monitoring of traction substations is a significant step in supporting operations

More information

BF 79 81

BF 79 81 BE1-11f FEEDER PROTECTION SYSTEM The BE1-11f is a multifunction numeric relay that provides three phase, ground, and negative sequence directional or non-directional overcurrent protection with four shot

More information

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers

Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers Switching Control Sentinel (SCS) TM For all ABB independent pole operated circuit breakers Switching Control Sentinel (SCS) for circuit breakers Voltage and current transients generated during switching

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

EDR-3000 Eaton Distribution Relay

EDR-3000 Eaton Distribution Relay EDR-3000 Eaton Distribution Relay Technical Data New Information Description Page 1. General Description.......................... 2 2. Applications............................... 2 3. Drilling Pattern.............................

More information

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential

More information

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES 1. Introduction Real time monitoring and control is necessary to ensure public and employee safety and to protect the integrity

More information

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution UR An integrated feeder protection and metering solution Power to Manage your Facility Connectivity ModBus RTU MMS/UCA2 TM Protocols SI Compatibility Flexibility FlexCurves FlexLogic The first Relay designed

More information

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter PM130 PLUS POWER METER The PM130 PLUS is a compact, multi-function, three-phase AC powermeter specially designed to meet the requirements of users ranging from electrical panel builders to substation operators.

More information

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

Feeder protection relay SPAA 121 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase

More information

QUALITROL QTMS Transformer Monitoring System

QUALITROL QTMS Transformer Monitoring System QUALITROL QTMS Transformer System Providing the Missing Piece in Your Condition Based Platform Modular design; full customization of monitoring parameters to meet specification Reduce installation and

More information

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay The power of fusion. 1874 1886 1893 1899 1906 1908 1911 1934 1962 1963 1976 1983 1990 1999 There s a certain energy at Eaton.

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

ENhanced TEChnology.  Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver. ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Ver. 081226 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser

More information

Products Portfolio. Pole mounted Vacuum Recloser

Products Portfolio. Pole mounted Vacuum Recloser Products Portfolio Pole mounted Vacuum Recloser Efacec Switchgear Efacec Switchgear is a leading company in Portugal and a worldwide reference in the development of solutions for power generation, transmission,

More information

URC Utility Relay Company

URC Utility Relay Company communications i-comm modbus / rs-485 AC-PRO Communicating Trip Units instruction manual ZERO-Hertz Communicating Trip Units URC Utility Relay Company Chagrin Falls, OH 44023 Phone: 888.289.2864 www.utilityrelay.com

More information

RT12-240V/2.4kW Rectifier Specification

RT12-240V/2.4kW Rectifier Specification The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between

More information

GRD110 FEATURES APPLICATION

GRD110 FEATURES APPLICATION FEATURES Overcurrent protection for phase and earth faults with IDMTL or DTL. Three instantaneous elements with DTL. Programmable reset characteristics. Sensitive earth fault protection (SEF). Restricted

More information

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet PowerLogic power-monitoring units digital panel meters Technical data sheet 2011 Authorized Distributor: WESCHLER INSTRUMENTS phone: 800-903-9870 440-378-6580 fax: 800-903-9590 440-238-0660 www.weschler.com

More information

Arc protection relay. Features Three-phase overcurrent function. Application

Arc protection relay. Features Three-phase overcurrent function. Application Arc protection relay REA 10_ Page 1 Issued: May 1999 Status: New Data subject to change without notice Features Three-phase overcurrent function Loop-type or radial sensor fibre for arc detection Two high-speed

More information