1 A -Wire Serial Interface TEMP05 Introduction... Using the TEMP05... TEMP05 ommands...6 Using the SET ommand...7 The DIS Display Output...8 DIS output explanations...8 What the heck is J6?...0 Software hange History... Legal Disclaimer... Introduction Thank you for your purchase of the TEMP05 kit. The following instructions assume that you have properly assembled the units according to instructions and that preliminary tests have been run. TEMP05 is a stand-alone -Wire interface providing standard serial commands to control the Dallas/Maxim -Wire bus and the devices used on it. The TEMP05 has the following features: TEMP05 User Guide Version Hc Page of

2 support for multiple DS8-based Humidity Sensors, including, of course, the Midon Design MD00E sensor. support for the JJWare DS8 based Barometric Sensors support for DS8 general purpose sensors for analog voltage input support for DS8S0, DS8S0-PAR, DS8B0, DS8, DS90 temperature sensors as well as temperature reading from any DS8 simultaneous temperature conversion for temperature sensors if all are equipped with local powering. This results in faster outputs. Note that a DS8 on the -Wire bus will prevent this feature from being enabled. support for the DS50 based Weather Station (wind speed and direction) - only one allowed. support for multiple DS based rain gauges support for multiple DS general purpose counters (for use with Lightning sensors and other types of counter inputs) support for DS05, DS06 or DS07 inputs and outputs. Use the DS05/6/7 to read alarm or PIR contacts. They are continuously polled (if -Wire readings are not being displayed) and TEMP05 will display a notice if the input changes state. If the state changes during a display period, the new state will be flagged following the display period. The DS05/6/7 can also be used to actuate relays or LED's in output mode. supports detection of DS0 or DS990 -Wire serial numbers jumper-less provisioning - all configuration settings stored in non-volatile memory up to 60 sensors supported simple instruction set easy to delete sensors, if they are no longer required, using the DEL command same access to the RELAY05 as the original TEMP05 -Wire bus errors are flagged when they occur Support for software serial flow control (ontrol-s, ontrol-q) continuous poll for ALL sensors - TEMP05 will notify you when any sensor is connected or disconnected, providing that they have been INI'd. Very useful for locating intermittent -Wire bus problems or for real-time polling of contact sensors. To complete this project, you will need to connect a to 6 Volt (A or D) transformer to the terminal J (see Figure for location of J). If you are using the auxiliary RELAY05 unit with TEMP05, choose a transformer that is as close to Volts as possible and that provides at least 0.8 Amperes. Otherwise, any to 6 Volt adapter capable of at least 00mA will do. TEMP05 User Guide Version Hc Page of

3 If you are using a sensor network of DS80's for temperature readings, connect them now to connector J. Only pins of each DS8S0 need be connected, however a connection is required between the VDD and GND pins of the DS80 if you are using parasitic power. See Figure's and for connections. On Rev G or higher PB s, a third terminal on J is provided for distributing +5V to the one-wire bus.. Figure DS8S0 Pin-out TEMP05 User Guide Version Hc Page of

4 Using the TEMP05 Figure Parts Placement Power up the TEMP05 and configure the unit for the devices that you have connected. onnect up a straight-through serial cable between TEMP05's P connector and your P. Open up HyperTerminal (or equivalent terminal emulator program) on your P. onfigure it to 9600 BPS, No parity, 8 bits, start bit and NO hardware handshaking (very important!). Power back up, if necessary, and then configure the unit for the devices you have connected. I recommend that you use the ERA command to erase the EEPROM first. This will remove any previous information that may have been stored in the EEPROM. Next use the INI command to search for any DS8S0's connected to the -Wire bus. If you get any error messages, it is most likely a TEMP05 User Guide Version Hc Page of

5 result of a bad connection to the DS8S0(s). Verify them. Typically, a "OW bus error" message indicates that a sensor has been installed in reverse, or that there is a short on the bus. Now program the configuration by using the SET command. Just type SET and the program will prompt you for the required settings; logging interval, Relay Timer interval, F/ display and wind direction reverse setting. To verify you are working, you can use the TMP command to perform an immediate sensor reading. The output of the TMP command should look like the sample below (the exact output will depend on what type and how many sensors you have installed). > Reading Sensors... Humidity #0[F B706]=55% Barometer #0[ B8E6]=9.98 inhg Barometer #0[ F568E6]=9.98 inhg Voltage #0[ ]= 0.V 0.99V Wind Dirn #0[DF ]= WNW Wind Speed[AAB0000DEF0D]= MPH, Gust =5 Lightning #0[8E D]=00768 Temp #0[ E6D0]=7.6F Temp #0[ B8E6]=8.5F Temp #0[000000E8]=7.50F Temp #0[ B8E6]=8.5F Temp #05[EA ]=69.58F Temp #06[F B706]=7.0F Temp #07[ A89D0]=7.95F > TEMP05 User Guide Version Hc Page 5 of

6 TEMP05 ommands These commands are valid for Version 5.00 and higher ommand Description Syntax DEB Enable or disable the Debug option setting. (for versions 5.00 and 5.0, DEB is a toggle command and does not require any additional parameters) DEB<on off> DEL Delete a sensor that was previously installed DEL<sensorid> DIS Display serial numbers of all configured -Wire devices DIS EEP Display and change specific EEPROM memory locations EEP <start location> ERA Erase the EEPROM ERA HLP Display a list of available commands HLP INI Search for a list of available -Wire sensors. INI MEM Display and change specific memory locations MEM <start location> NOR Set North for a -Wire Weather Station NOR OFA Turn OFF a DS05, 06 or 07 -Wire device OFA<sensorid> ONA Turn ON a DS05,06 or 07 -Wire device ONA<sensorid> RLB Actuate all relays at once RLB x where x = an 8 bit binary number representing all relays. The MSB is relay 8. A turns on a relay. TEMP05 User Guide Version Hc Page 6 of

7 RLY midon design Actuate a specific relay RLY <relay number> <on off> where <relay number> = to 8 or A for All RLY S (displays status of all relays) RST Reset any DS counter RST<sensorid> SET onfigure the interval and F/ display SET TMP Display temperatures of all connected DS8S0's in either verbose (includes serial numbers) or non-verbose (similar to GET) manner TMP TYP Select the type of DS8 or DS device TYP<sensorid> VER Displays the current version of the software loaded VER ZZZ Performs a soft reset of TEMP05 ZZZ Using the SET ommand The SET command has multiple parameters. Update Interval determines the time between sensor readings. Set to 0 to stop polling (Note: this is only available in versions 5. and higher). Enter the time in decimal minutes. Relay Off Timer determines how much time to wait between turning on ANY relay and turning them ALL off. Enter the time in decimal minutes. Enter 0 to disable this function. F or Display determines how temperature readings are displayed. Enter F for Fahrenheit or for elsius. Serial # Display - set to Yes if you want TEMP05 to display the -wire ID of all sensors. Wind Dirn Reverse - set normally to N. Set this to Y if you accidentally installed the wind direction PB upside down in your weather station OR if you want to display wind direction as the FROM direction instead of the TO direction. TEMP05 User Guide Version Hc Page 7 of

8 The DIS Display Output DS80 OK DS8 OK DS8B OK DS80 OK DS8 OK H DS8 OK B DS8 OK V 08 AAFED0000BA6 DS8 OK H 09 AABD0000EF0D DS OK W ABD DS OK R 5AB0000DD DS OK L FF66FF00FFFFFFFF??? NG 9F ADE05 DS05 OK Update interval = 0 minutes Temp display = F Serial # display = On Wind dirn reverse = Off Relay off timer= 00 minutes Some temp sensors Parasitic powered Qty of DS80 = Qty of DS8 = Qty of DS8B = Qty of DS8 = midon design Sample DIS Output DIS output explanations Sensor numbers do not necessarily match up with the output from the regular sensor output readings. This is intentional. The sensor numbers in the DIS output are the memory locator and are used by the DEL, RST, ONA, OFA and TYP commands. The sensor numbers in the scan output are sequential numbers for each type of sensor. An OK will be displayed following the sensor type to indicate that the yclic Redundancy ounter (R) checksum of the sensor's serial number is good. If the serial number has a bad R, an NG will be displayed. The checksum is validated during the output of the sensor display. Letters following the DS and DS8 indicate the TYPe of sensor equipped. This is a manual input and will be set following first discovery of the sensor via the INI command, and also following a power-up of the TEMP05 for the DS sensors that do not have built-in battery backup. The letters designate the sensor type per the following table. Sensor Types Designation Description OW Device H Humidity Sensor DS8 TEMP05 User Guide Version Hc Page 8 of

9 B Barometric Sensor DS8 L Lightning Sensor DS W Wind Speed Sensor DS R Rain Sensor DS V Voltage Sensor DS8 Following a display of the sensors installed, the output of the DIS display then shows the TEMP05 settings that you entered via the SET command. The DEBug mode is then shown. To turn on or off the DEBug mode, use the DEB command. Following that, the DIS display then checks to see if all temperature sensors are parasitically or locally powered. If ANY temperature sensor connected to the - Wire bus is set to parasitic mode, then the display will show "some sensors parasitic powered". The same display will result of ANY DS8 devices are present on the -Wire bus. Following that display the DIS output proceeds to show how many temperature sensors are installed, by type. The DS8B type indicates a DS8B0 sensor. The DS80 type is valid for DS80, DS8S0 and DS90 sensors. TEMP05 User Guide Version Hc Page 9 of

10 P DB9 To User Terminal U TOUT TOUT RIN RIN TIN TIN ROUT ROUT V- 7 - V- MAX V+ D LED Bipolar J J pin DIP Term D - + pfd pfd R 0M +5V Y.0MHz RA 0K 0K RA U LM78L05 IN Out + +5V 0uFd U PA0 PA PA PA PA PA5 PA6 PA7 OS OS TAP PD0 PD5 PD7 IRQ RST VDD 68H7058 PB0 PB PB PB PB PB5 PB6 PB7 P0 P P P P P5 P6 P7 PD PD PD PD TMP +5V LED LED S LK DO DI DATA J ON8 R5.5K +5V U S LK Test DI ORG DO 956 ON 7 6 J Power & Ground Table U Vcc =0 Gnd=0 U V=7 GND=6,9 U V=8 GND=5 D9 N8 D N8 +5V One-Wire Bus BRIDGE 6 0.uFd uFd GND + 00uFd Title TEMP05 - One Wire Thermometer System What the heck is J6? Figure TEMP05 Schematic Diagram (REV G) Size Document Number Rev A SD Date: Sunday, December 09, 00 Sheet of On rev G or higher PB s, there is a spot for inserting a RJ-, RJ-, or ibutton holder. This location is connected to the One Wire bus and can be used for adding connectivity to One Wire busses configured for RJ-/ connection. This can also be used, but not at the same time, as a place to insert an ibutton. A Dallas/Maxim ibutton holder DS909F is required to use J6 for ibutton connection. Midon Design does not supply either of the optional connectors for J6. TEMP05 User Guide Version Hc Page 0 of

11 Software hange History Figure J6 RJ Pinout Version Date Major hanges from Previous Loads 5. //0 Added timeout for inactive inputs (to avoid locking up TEMP05 if a power failure occurs). Added On/Off input to the DEB command. Added a >00% indicator for humidity readings. Fixed a bug where a DIS display in the middle of a sensor poll would disrupt the sensor ID numbers. Fixed a bug where Polling Interval =0 would still cause a minute poll. 5.0 //0 Added ability to use either 966 or 956 EEPROM //0 Many new features added..5 //0 Added 966 EEPROM capabilities with an autocheck on power up for EEPROM type.. /0/0 Minor tweaks to code size. /5/0 Added parasitic check and display for DIS and QTY commands.. 0/6/0 Fixed HUM command to ensure continuation of humidity readings even after an error on one reading.. 9//00 Added support for DS8B0 and DS8 temperature sensors. Added check on OW bus for shorts or reversed sensors. QTY command now counts DS8S0, DS8B0 and DS8 sensors separately. hanged sensor numbering to start at instead of zero..0 8/0/00 Fixed bug in.9 - will only read humidity sensor..9 8/0/00 ode compaction only.8 7//00 Added REV and RLT commands..7 7/9/00 Added support for V OWWS by AAG. Added NOR command to set true north on OWWS. Added RLB command to control all Relays at once. TEMP05 User Guide Version Hc Page of

12 .6 7/7/00 Beta version of DS50 based weather station support.5 6/6/00 Added QTY command. 5/7/00 Added capability of connecting multiple humidity sensors. 5//00 Added R command. /0/00 Added humidity sensor capability and increased temperature display precision Your comments are appreciated. If you would like to submit feature requests or product recommendations, please us. Please also check the Frequently Asked Questions link on the TEMP05 web page. Legal Disclaimer YOUR USE OF THIS PRODUT IS AT YOUR OWN RISK. YOU ASSUME FULL RESPONSIBILITY AND RISK OF LOSS RESULTING FROM THE USE OF THIS PRODUT. MIDON DESIGN WILL NOT BE LIABLE FOR ANY DIRET, SPEIAL, INDIRET, INIDENTAL, ONSEQUENTIAL OR PUNITIVE DAMAGES OR ANY OTHER DAMAGES WHATSOEVER, WHETHER IN AN ATION BASED UPON A STATUTE, ONTRAT, TORT (INLUDING, WITHOUT LIMITATION NEGLIGENE) OR OTHERWISE, RELATING TO THE USE OF THIS PRODUT. Thank you! mitch@midondesign.com opyright Midon Design. All rights reserved. No part of this document may be reproduced, recorded, transmitted or distributed in any form or by any means without the written consent of Midon Design. End of Document TEMP05 User Guide Version Hc Page of

midon design A Temperature Logging Serial Interface TEMP05

midon design A Temperature Logging Serial Interface TEMP05 A Temperature Logging Serial Interface TEMP0 Introduction... Using the TEMP0... TEMP0 ommands... Jumper Definitions... What the heck is J?... Software hange History... Legal Disclaimer... Introduction

More information

midon design A 1-Wire Serial Interface TEMP08 Figure 1 TEMP08 TEMP08 V2.20 Syntax June 27, 2010 TEMP08 V2.20 Syntax Page 1 of 24

midon design A 1-Wire Serial Interface TEMP08 Figure 1 TEMP08 TEMP08 V2.20 Syntax June 27, 2010 TEMP08 V2.20 Syntax Page 1 of 24 A 1-Wire Serial Interface TEMP08 Figure 1 TEMP08 TEMP08 V2.20 Syntax June 27, 2010 TEMP08 V2.20 Syntax Page 1 of 24 1. Table of Contents 1. Table of Contents...2 1.1. List of Tables...3 2. Introduction...4

More information

midon design A 1-Wire Serial Interface 1WSwitch Figure 1 1WSwitch 1WSwitch User Guide Version 1.02 November 18, 2008

midon design A 1-Wire Serial Interface 1WSwitch Figure 1 1WSwitch 1WSwitch User Guide Version 1.02 November 18, 2008 A 1-Wire Serial Interface 1WSwitch Figure 1 1WSwitch 1WSwitch User Guide Version 1.02 November 18, 2008 1WSwitch User Guide Version 1.02 Page 1 of 28 1. Table of Contents 1. Table of Contents...2 1.1.

More information

midon design A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, WIO User Guide Version 1.

midon design A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, WIO User Guide Version 1. A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, 2009 1WIO User Guide Version 1.7 Page 1 of 14 1WIO User Guide Version 1.7 1. Table of Contents 1. Table of Contents...2 1.1. List

More information

USB-Based 14-Channel Data-Acquisition Module

USB-Based 14-Channel Data-Acquisition Module USB-Based 14-Channel Data-Acquisition Module DLP-IO14 LEAD FREE FEATURES: 14 IO s: 0-5V Analog, Digital In/Out, Temperature Two Bipolar Analog Inputs; ±5V Input Range Max All Analog Inputs: Up to 30Ksps

More information

A Programmer for the 68HC705C8 MicroController Figure 1 PROG05 As Built PROG05 User Guide Version C1 Page 1 of 14

A Programmer for the 68HC705C8 MicroController Figure 1 PROG05 As Built PROG05 User Guide Version C1 Page 1 of 14 A Programmer for the 68HC705C8 MicroController Figure 1 PROG05 As Built PROG05 User Guide Version C1 Page 1 of 14 Table of Contents midon design 1. Introduction...3 2. Description...4 3. Construction...5

More information

For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference.

For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference. For more detailed instruction, see the KTA-282 user manual. This document is a condensed version; intended as a reference. Weather Station Setup Configuring the KTA-282 Connection Description V + Power

More information

USB-Based 14-Channel Data-Acquisition Module

USB-Based 14-Channel Data-Acquisition Module USB-Based -Channel Data-Acquisition Module DLP-IO LEAD FREE FEATURES: IO s: 0- Analog, Digital In/Out, Temperature Two Bipolar Analog Inputs; ± Input Range Max All Analog Inputs: Up to 0Ksps Sample Rate

More information

KTA-250 Anemometer Alarm Card

KTA-250 Anemometer Alarm Card Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments

More information

USB-BASED 8-CHANNEL DATA ACQUISITION MODULE

USB-BASED 8-CHANNEL DATA ACQUISITION MODULE DLP-IO8-G *LEAD-FREE* USB-BASED 8-CHANNEL DATA ACQUISITION MODULE Features: 8 Channels: Digital I/O, Analog In, Temperature USB Port Powered USB 1.1 and 2.0 Compatible Interface Small Footprint; Easily

More information

USB-Based 20-Channel Data-Acquisition Module

USB-Based 20-Channel Data-Acquisition Module USB-Based 0-Channel Data-Acquisition Module DLP-IO0 LEAD-FREE FEATURES: 0 Channels: Analog Inputs 0-V, Up to 0Ksps Sample Rate, Latching Relays, Digital I/O Two Relay Driver Outputs (V Coil) Digital Temperature

More information

Instruction Manual for IEEE Prototyping Kit (PC Version)

Instruction Manual for IEEE Prototyping Kit (PC Version) Instruction Manual for IEEE 1451.4 Prototyping Kit (PC Version) 1 st Edition Esensors Inc Amherst NY IEEE 1451.4 Prototyping Kit (PC Version) ii COPYRIGHTS The information in this document is subject to

More information

5800 Series Non-IntelliTEAM Universal Automatic Switch Control PG&E SCADA Points List

5800 Series Non-IntelliTEAM Universal Automatic Switch Control PG&E SCADA Points List S&C Electric Company 5800 Series Non-IntelliTEAM Universal 5800 Series Non-IntelliTEAM Universal PG&E SCADA Points List PG&E SCADA Points List for: 5801 Universal Control with USBP0S0X Software and 5802

More information

DIGITAL COMPASS SOLUTION

DIGITAL COMPASS SOLUTION Features 5 Heading Accuracy, 0.5 Resolution 2-axis Capability Small Size (19mm x 19mm x 4.5mm), Light Weight Advanced Hard Iron Calibration Routine for Stray Fields and Ferrous Objects 0 to 70 C Operating

More information

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp. C-Programmable Controller P00 Series The P00 Series of C-programmable controllers is based on the Zilog Z80 microprocessor. The P00 includes digital, serial, and high-current switching interfaces. The

More information

0.1 Slow Monitoring and Recording System

0.1 Slow Monitoring and Recording System 0.1 Slow Monitoring and Recording System A slow monitoring and control system is required to control systematic effects that could impact the experiment, to allow automated scans of parameters such as

More information

Flash Microcomputer Programmer

Flash Microcomputer Programmer Flash Microcomputer Programmer User's Manual Tessera Technology Inc. Date published: August 2017 (6th Edition) TABLE OF CONTENTS CHAPTER 1 OVERVIEW... 5 1.1 System Configuration... 6 CHAPTER 2 INSTALLATION...

More information

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

Getting Started with your D3000M Series Module

Getting Started with your D3000M Series Module Getting Started with your D3000M Series Module This document contains step-by-step instructions to quickly connect and communicate with your D3000M modules. The modules require a one-time configuration

More information

Figure 1. LCD & Keypad - RS232 Terminal

Figure 1. LCD & Keypad - RS232 Terminal LCD & Keypad - RS Terminal ADVANCE INFORMATION ALL INFORMATION IN THIS USER MANUAL IS PRELIMINARY AND SUBJECT TO CHANGE. LCD & Keypad - RS Terminal (R. Feb 005) 00 by DV Industrial Computer Introduction

More information

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules Analog Input Modules Analog Current Input - 16 Channel IC693ALG223 The 16-Channel Analog Current Input module provides up to 16 single-ended input channels, each capable of converting an analog input signal

More information

Axiom Manufacturing. Users Manual. for PROJECT DEVELOPMENT BOARD AXM xiom anufacturing

Axiom Manufacturing. Users Manual. for PROJECT DEVELOPMENT BOARD AXM xiom anufacturing Axiom Manufacturing Users Manual for PROJECT DEVELOPMENT BOARD AXM-0295 xiom anufacturing 1999 2813 Industrial Ln. Garland, TX 75041 (972) 926-9303 FAX (972) 926-6063 support@axman.com Rev 1.0 web: http://www.axman.com

More information

Interface BL232 with RS232/422/485 MODBUS and 0-10V outputs. Interface BL232

Interface BL232 with RS232/422/485 MODBUS and 0-10V outputs. Interface BL232 BIT LINE WEATHER INSTRUMENTS Interface BL232 with RS232/422/485 MODBUS and 0-10V outputs Qick and easy setup For domotic and building automation Wide Range power supply For solar and wind farm BIT LINE

More information

KDR00301 DMX Controlled Relay Kit

KDR00301 DMX Controlled Relay Kit KDR00301 DMX Controlled Relay Kit This is a DMX512-A relay kit using ANSI approved RJ-45 connectors for DMX networks. Power requirements are 12 Vdc @ 200 ma. The relay contact rating is 10 Amp @ 120 or

More information

EE4390 Microprocessors. Lessons 2, 3 68HC12 Hardware Overview, Subsystems, and memory System

EE4390 Microprocessors. Lessons 2, 3 68HC12 Hardware Overview, Subsystems, and memory System EE4390 Microprocessors Lessons 2, 3 68HC12 Hardware Overview, Subsystems, and memory System 1 Overview 68HC12 hardware overview Subsystems Memory System 2 68HC12 Hardware Overview "Copyright of Motorola,

More information

GPS Evaluation Kit A1080

GPS Evaluation Kit A1080 GPS Evaluation Kit A1080 A description of an evaluation system for Vincotech s GPS Receiver Module A1080-A/-B User s Manual Version 4.0 Hardware Revision 02 Revision History Rev. Date Description 1.0 12-05-06

More information

DeviceNet Communications Unit Enables Program-free Communications with Temperature Controllers. DeviceNet Communications Unit E5ZN-DRT

DeviceNet Communications Unit Enables Program-free Communications with Temperature Controllers. DeviceNet Communications Unit E5ZN-DRT ommunications Unit -DRT SM_-DRT_DS_E_3_1 Streamlined ommunications from Temperature ontroller to PL The Modular Temperature ontroller is connected to the network. The I/O link function allows setting and

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter

USB Debug Adapter. Power USB DEBUG ADAPTER. Silicon Laboratories. Stop. Run. Figure 1. Hardware Setup using a USB Debug Adapter C8051F38X DEVELOPMENT KIT USER S GUIDE 1. Kit Contents The C8051F38x Development Kit contains the following items: C8051F380 Target Board C8051Fxxx Development Kit Quick-start Guide Silicon Laboratories

More information

The DS2703 EV kit evaluation software gives the user complete control of all SHA-1 functions of the DS2703 as well as the various other commands.

The DS2703 EV kit evaluation software gives the user complete control of all SHA-1 functions of the DS2703 as well as the various other commands. 19-4832; Rev 10/09 www.maxim-ic.com FEATURES Demonstrates the capabilities of the DS2703 Battery Pack Authentication IC with SHA-1 Security, including: Secure Challenge and Response Authentication using

More information

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install TPDIN-Monitor-WEB Web Based Monitor and Control Remote Power Stations Backup Power Systems Solar Systems Wind Powered Systems Industrial Sense & Control Process Automation Congratulations! on your purchase

More information

DS2788K Evaluation Kit Standalone Fuel Gauge IC with LED Display Drivers

DS2788K Evaluation Kit Standalone Fuel Gauge IC with LED Display Drivers s DS2788K Evaluation Kit Standalone Fuel Gauge IC with LED Display Drivers www.maxim-ic.com FEATURES Demonstrates the capabilities of the DS2788 Standalone Fuel Gauge IC with LED Display Drivers, including:

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

MAX197 Evaluation Kit. Evaluates: MAX197/MAX199. Features

MAX197 Evaluation Kit. Evaluates: MAX197/MAX199. Features 9-0398; Rev ; 7/95 MAX97 Evaluation Kit General Description The MAX97 evaluation system (EV system) is a complete, low-cost, 8-channel data-acquisition system consisting of a MAX97 evaluation kit (EV kit)

More information

CMS-8GP32. A Motorola MC68HC908GP32 Microcontroller Board. xiom anufacturing

CMS-8GP32. A Motorola MC68HC908GP32 Microcontroller Board. xiom anufacturing CMS-8GP32 A Motorola MC68HC908GP32 Microcontroller Board xiom anufacturing 2000 717 Lingco Dr., Suite 209 Richardson, TX 75081 (972) 994-9676 FAX (972) 994-9170 email: Gary@axman.com web: http://www.axman.com

More information

Table of Contents. Version 1.5 ibuttonlink The MultiSensor User Guide. Page 3

Table of Contents. Version 1.5 ibuttonlink The MultiSensor User Guide. Page 3 Table of Contents List of Tables... 4 List of Figures... 4 Introduction... 5 Copyright Notices... 5 Contact Information... 5 Common Features... 6 Power... 6 Casing... 6 Connectors... 6 Temperature Considerations

More information

A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE

A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE SCADA INTERFACE INSTRUCTIONS - OPTION 21P / 21Q - FOR A36D/TPSD SYSTEMS A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE OPTION 21P / 21Q INSTRUCTIONS This manual is only valid for A36D/TPSD Chargers equipped

More information

+Denotes lead(pb)-free and RoHS compliant.

+Denotes lead(pb)-free and RoHS compliant. 19-4855; Rev 1; 10/09 General Description The DS2784 evaluation kit (EV kit) allows easy performance evaluation, software development, and prototyping with the DS2784 1-cell stand-alone fuel gauge IC with

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

USER S MANUAL VER.1. C34GV BOARD Rev. 1

USER S MANUAL VER.1. C34GV BOARD Rev. 1 USER S MANUAL VER.1 C34GV BOARD Rev. 1 JANUARY, 2017 USER'S MANUAL TABLE OF CONTENTS Contents Page # 1.0 OVERVIEW... 1 2.0 FEATURES... 1 3.0 BOARD DESCRIPTION... 2 4.0 SPECIFICATIONS... 2 4.1 Power Requirements...

More information

EQ7000. User Manual. Rev 1.00

EQ7000. User Manual. Rev 1.00 EQ7000 User Manual Rev 1.00 www.equustek.com Revision 1.00 February 27, 2009 Contents INTRODUCTION...4 ABOUT THIS MANUAL...4 INTENDED AUDIENCE...4 HARDWARE SPECIFICATIONS...5 PHYSICAL SPECIFICATIONS...5

More information

ATmega48/88/168 Development Board

ATmega48/88/168 Development Board ATmega// Development Board This is versatile development board for AVR microcontrollers ATmega//. It is good for testing and debugging embedded programs. It has many built-in peripheries connected to microcontroller

More information

DS2756EVKIT+ High Accuracy Battery Fuel Gauge With Programmable Suspend Mode Evaluation Kit

DS2756EVKIT+ High Accuracy Battery Fuel Gauge With Programmable Suspend Mode Evaluation Kit 19-4847; Rev 9/09 www.maxim-ic.com FEATURES Demonstrates the capabilities of the DS2756 High Accuracy Battery Fuel Gauge, including: Programmable Suspend Mode Temperature measurement Voltage measurement

More information

DS2781EVKIT+ Standalone Fuel Gauge IC Evaluation Kit

DS2781EVKIT+ Standalone Fuel Gauge IC Evaluation Kit 19-4852; Rev 9/09 Standalone Fuel Gauge IC Evaluation Kit www.maxim-ic.com FEATURES Demonstrates the capabilities of the DS2781 Standalone Fuel Gauge, including: Estimation of available capacity for Li+

More information

Blue Point Engineering

Blue Point Engineering Blue Point Engineering Board - Pro Module (E) Instruction Pointing the Way to Solutions! Controller I Version 2.1 The Board Pro E Module provides the following features: Up to 4 minutes recording time

More information

KDR00101 DMX Controlled Relay Kit

KDR00101 DMX Controlled Relay Kit KDR00101 DMX Controlled Relay Kit This is a DMX512-A relay kit using ANSI approved RJ-45 connectors for DMX networks. Power requirements are 12 Vdc @ 100 ma. The relay contact rating is 10 Amp @ 120 or

More information

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 -

PROFESSIONAL WIRELESS WEATHER STATION. Operation Manual - 1 - PROFESSIONAL WIRELESS WEATHER STATION Operation Manual - 1 - OVERVIEW Outdoor sensor: 1. Wind Vane 2. Wind Speed Sensor 3. Solar panel 4. Battery compartment 5. LED Indicator: light on for 4 seconds during

More information

Hybrid AC Driver [GCNC-1110]

Hybrid AC Driver [GCNC-1110] Page 1 Installation Manual and Datasheet Page 2 Key Features Smooth and quiet operation at all speeds and extremely low motor heating Industrial grade performance for an alternating current servo motor

More information

DS1676 Total Elapsed Time Recorder, Erasable

DS1676 Total Elapsed Time Recorder, Erasable www.dalsemi.com Preliminary DS1676 Total Elapsed Time Recorder, Erasable FEATURES Records the total time that the Event Input has been active and the number of events that have occurred. Volatile Elapsed

More information

Bolt 18F2550 System Hardware Manual

Bolt 18F2550 System Hardware Manual 1 Bolt 18F2550 System Hardware Manual Index : 1. Overview 2. Technical specifications 3. Definition of pins in 18F2550 4. Block diagram 5. FLASH memory Bootloader programmer 6. Digital ports 6.1 Leds and

More information

HuertomatoUser'sGuide

HuertomatoUser'sGuide HuertomatoUser'sGuide Huertomato is an Arduino based controller for the management of hydroponics systems. It consists of an Arduino MEGA 2560 shield and a reservoir module. It has all the sensors you

More information

ED1021 I/O Expander with UART interface & analog inputs

ED1021 I/O Expander with UART interface & analog inputs Preliminary Highlights 4.5V 5.5V power supply range. 12 GPIOs. Up to 40mA maximum current in each output except GPIO8 (up to a total device current of 175mA). Most GPIOs can be an input to a 10bit ADC.

More information

LAN9512 Evaluation Board User Manual

LAN9512 Evaluation Board User Manual Copyright 2012 SMSC or its subsidiaries. All rights reserved. Circuit diagrams and other information relating to SMSC products are included as a means of illustrating typical applications. Consequently,

More information

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required

JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required JNIOR Series 3 A Network I/O Resource Utilizing the JAVA Platform Getting Started Manual Release 3.3 NOTE: JNIOR OS 3.4 or greater required INTEG Process Group, Inc. 2919 East Hardies Rd, First Floor Gibsonia,

More information

HA7E-User Manual ASCII RS232 to 1-Wire Host Adapter

HA7E-User Manual ASCII RS232 to 1-Wire Host Adapter HA7E-User Manual ASCII RS232 to 1-Wire Host Adapter http://www.embeddeddatasystems.com FEATURES ASCII command support for all 1-Wire devices. Powered by RS232 handshake lines. Automatic power up and power

More information

Digital Thermometer and Thermostat in SOT23

Digital Thermometer and Thermostat in SOT23 General Description The digital thermometer and thermostat provides temperature readings that indicate the device s temperature. Thermostat settings and temperature readings are all communicated to/from

More information

DATA LOGGER GEOLOGGER G8 PLUS

DATA LOGGER GEOLOGGER G8 PLUS A D V A C E D DATA LOGGER GEOLOGGER G8 PLUS I N S T CONFIGURATION & WIRING OF PERIPHERALS R U C T I O N M A N U A L 1 CONTENTS DESCRIPTION PAGE Main components 3 G8 Module Connections 4 G8 Module Connections

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control Installation Manual SM-RS232 16-Port RS232 Router with optional TCP/IP control Control up to 16 RS232 compliant devices up to 50 feet away over UTP or from anywhere via TCP/IP (optional) What s in the

More information

TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC. Operation Manual

TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC. Operation Manual TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC Operation Manual About this manual Thank you and congratulations on selecting this professional weather station! We are positive you will

More information

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1 TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...

More information

IT900 STK4 (Starter Kit)

IT900 STK4 (Starter Kit) PRELIMINARY IT900 STK4 (Starter Kit) February 2011 Copyright YITRAN Communications Ltd. PRELIMINARY information concerns products in the formative or design phase of development. Characteristic data and

More information

Quick Start Installation Guide

Quick Start Installation Guide istar Pro Quick Start Installation Guide Version B0 Part Number UM-069 January 2005 OVERVIEW This guide defines all of the commonly used connection methods to the istar Pro. It outlines how to wire readers

More information

ED1021 I/O Expander with UART interface & analog inputs

ED1021 I/O Expander with UART interface & analog inputs Preliminary Highlights 2.7V 5V power supply range. 12 GPIOs. Up to 40mA maximum current in each output except GPIO8 (up to a total device current of 175mA). Most GPIOs can be an input to a 10bit ADC. Simple

More information

Soekris Engineering. net4801 series boards and systems. User s Manual

Soekris Engineering. net4801 series boards and systems. User s Manual Soekris Engineering net4801 series boards and systems. User s Manual Vers 0.05 April 10, 2004 Table of Contents 1 INTRODUCTION...4 1.1 Overview... 5 1.2 Bus Expansion... 5 1.3 Multi-IO Controller... 6

More information

For the LAN91C111 TQFP package, the Vdd and AVdd pins are located as follows: Pin #1, #11, #16, #33, #44, #62, #77, #98, #110, #120.

For the LAN91C111 TQFP package, the Vdd and AVdd pins are located as follows: Pin #1, #11, #16, #33, #44, #62, #77, #98, #110, #120. AN 11.2 1 Purpose Current Measurements and Measurement Procedures for the LAN91C111 and LAN91C111 Evaluation Board This application note provides measurements of the current (ICC) consumed by the LAN91C111

More information

Communicative controller for VAV systems

Communicative controller for VAV systems FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration

More information

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual 2011 Model (DRS-54V) Ver. 2.0 August DRS-54V Dongah Rectifier System AC 240V 1Phase 3WIRE Input -54VDC Output 55A per Shelf 18.5Amps per Module DONGAHELECOMM.LTD _ Proprietary This document contains proprietary

More information

D/E Remote Relay Panel User Guide

D/E Remote Relay Panel User Guide D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2

More information

mcstemperature Homeseer Support for Temperature Recording and Display of Local Sensors and Web-based Meteorological Data

mcstemperature Homeseer Support for Temperature Recording and Display of Local Sensors and Web-based Meteorological Data mcstemperature Homeseer Support for Temperature Recording and Display of Local Sensors and Web-based Meteorological Data By Michael McSharry and Bill Walton December 27, 2007 Table of Contents 1 Introduction...1

More information

HMC1022 Digital Compass

HMC1022 Digital Compass Key Features Based on Honeywell s HMC1022 solid-state magnetic sensor Choice of 2 Interface Options (UART/I2C) Standard Pin Headers come soldered Plug and Play Module SPECIFICATIONs Angular Measuring Range

More information

installation quick guide integrated access control & environmental monitoring

installation quick guide integrated access control & environmental monitoring installation quick guide integrated access control & environmental monitoring Introduction This Installation Quick Guide is suitable for standard wallmountable AX300 controllers. Illustrative technical

More information

BARIX X8. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications. Version: 2.01.

BARIX X8. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications. Version: 2.01. BARIX X8 I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRODUCT MANUAL Version: 2.01 Date: 27/03/2015 For Firmware Version 13 Table of Contents Introduction...1

More information

Xitanium LED drivers - linear HV non-isolated - Sensor Ready. LED specs comparable to TD non-isolated drivers

Xitanium LED drivers - linear HV non-isolated - Sensor Ready. LED specs comparable to TD non-isolated drivers Xitanium LED driver Datasheet Xitanium LED drivers - linear HV non-isolated - Sensor Ready Simplifying connectivity solutions with sensors and controls Philips Sensor Ready drivers are ideal for use with

More information

DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS FOR 205T BASED SYSTEMS

DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS FOR 205T BASED SYSTEMS DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS - OPTION 21PQ - FOR 205T BASED SYSTEMS DNP 3.0 & Modbus SCADA INTERFACE OPTION 21PQ INSTRUCTIONS FOR 205T BASED SYSTEMS CPN114830 ECN/DATE ISSUE DATE: ECN

More information

INTMOD485-LH Protocol Converter

INTMOD485-LH Protocol Converter For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion

More information

Appendix. Auxiliary Functions. In This Appendix...

Appendix. Auxiliary Functions. In This Appendix... uxiliary Functions ppendix In This ppendix... Introduction... UX * RLL Operations... UX * V-memory Operations... UX * I/O onfiguration... UX * PU onfiguration... UX * Handheld Programmer onfiguration...

More information

LBI-38599F Maintenance Manual

LBI-38599F Maintenance Manual Maintenance Manual MASTR IIe Utility Handset TABLE OF CONTENTS INTRODUCTION................................................... 3 DESCRIPTION.................................................... 3 Control

More information

AVR- M16 development board Users Manual

AVR- M16 development board Users Manual AVR- M16 development board Users Manual All boards produced by Olimex are ROHS compliant Rev. C, January 2005 Copyright(c) 2009, OLIMEX Ltd, All rights reserved Page1 INTRODUCTION AVR-M16 is header board

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

3.3V regulator. JA H-bridge. Doc: page 1 of 7

3.3V regulator. JA H-bridge. Doc: page 1 of 7 Digilent Cerebot Board Reference Manual Revision: 11/17/2005 www.digilentinc.com 215 E Main Suite D Pullman, WA 99163 (509) 334 6306 Voice and Fax Overview The Digilent Cerebot Board is a useful tool for

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

Flex Series User Guide

Flex Series User Guide User Programmable Current 4..20mA Digital RS485 Dual & Single Axis Up to 360º 2016 Flex Series User Guide Sensor Installation, Wiring, Flexware App Instructions Page 1 of 33 Page 2 of 33 Table of Contents

More information

GAME OF THRONES SERVICE AND OPERATION MANUAL

GAME OF THRONES SERVICE AND OPERATION MANUAL GAME OF THRONES SERVICE AND OPERATION MANUAL WARNING MANUAL #780-50G4-00 GAME OF THRONES PRO #500-55G4-01 1-800-KICKERS - parts.service@sternpinball.com www.sternpinball.com - facebook.com/sternpinball

More information

WeatherPlus Board

WeatherPlus Board Features and Benefits: The is an stand alone and interface board for connecting a full featured, customizable board for Raspberry Pi and Arduino projects with an on-board ESP8266 WiFi. It contains a built

More information

PIC-P40 development board Users Manual

PIC-P40 development board Users Manual PIC-P40 development board Users Manual All boards produced by Olimex are ROHS compliant Rev.E, February 008 Copyright(c) 008, OLIMEX Ltd, All rights reserved Page INTRODUCTION: PIC-P40 board is development

More information

WeatherPiArduino Weather Board

WeatherPiArduino Weather Board Product Specification Features and Benefits: Provides an excellent interface for a Weather! The is an interface board for connecting a full featured, customizable board for Raspberry Pi and Arduino projects.

More information

ZLog Z7 High Altitude Data Logging System

ZLog Z7 High Altitude Data Logging System ZLog Z7 High Altitude Data Logging System 2013-02-04 Page 1 of 16 Introduction ZLog was designed to provide a lightweight, compact device for measuring and recording data in high-altitude scientific experiments.

More information

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or EQ7000 User Manual Rev 1.04 www.equustek.com Revision 1.04 Feb 20th, 2017 #286-5489 Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: 888-387-3787 or 604-266-8547 www.equustek.com Page 1 Contents INTRODUCTION...4

More information

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1) COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER No.KTC3E2 2006.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. For this product

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Evaluation Board User Guide UG-047

Evaluation Board User Guide UG-047 Evaluation Board User Guide UG-047 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com Evaluating the ADT7310/ADT7410 Temperature Sensors

More information

REMOTE TEMPERATURE MONITORING SYSTEM VIA INTERNET, USING A DS18B20 SENSOR

REMOTE TEMPERATURE MONITORING SYSTEM VIA INTERNET, USING A DS18B20 SENSOR REMOTE TEMPERATURE MONITORING SYSTEM VIA INTERNET, USING A DS18B20 SENSOR Irinel GEORGESCU *, Bogdan VASILESCU ** *Petroleum-Gas University, Bd. Bucureşti 39, Ploiesti 100680, irinelgeorgescu@gmail.com

More information

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual Intelligent Devices IDI 6005 Speed Sign Controller 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights

More information

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V.

This Datasheet for the IC670ALG310. Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V. This Datasheet for the IC670ALG310 Analog Output Voltage, 8 Channel, +/-10V, 0 to 10V http://www.qualitrol.com/shop/p-14493-ic670alg310.aspx Provides the wiring diagrams and installation guidelines for

More information

DS1625. Digital Thermometer and Thermostat FEATURES PIN ASSIGNMENT

DS1625. Digital Thermometer and Thermostat FEATURES PIN ASSIGNMENT DS1625 Digital Thermometer and Thermostat FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is 67 F to

More information

Low-Power-Radio Transceiver IC

Low-Power-Radio Transceiver IC Addressed Mode With Acknowledge Broadcast Mode Automatic Retry Serial Interface Stand Alone Operation Achieves Maximum Range From RF Modules Flow Control Option Two Telemetry I/O Lines (addressed mode

More information

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/ Rev. A 1/25/213 172 Contents Contents Temperature-Humidity Sensor Configuration Tool... 3 Read Sensor Screen... 3 Manual Calibration Screen... 4 Register View Screen... 5 Modbus Registers... 6 Reprogram

More information

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2. BARIX IO12 I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL Version: 2.01 Date: 06/03/2014 For Firmware Version 10 Table of Contents

More information

DS2760K Li + Battery Monitor Evaluation Kit

DS2760K Li + Battery Monitor Evaluation Kit Li + Battery Monitor Evaluation Kit www.dalsemi.com FEATURES Demonstrates the capabilities of the DS2760 Li + Battery Monitor, including: Temperature measurement Voltage measurement Current measurement

More information