1 STARDELTA-EN - User Manual STAR/DELTA STARTING PANEL FOR ELECTRIC PUMP - STANDARD EN
2
3 CONTENTS 1. INTRODUCTION WARNINGS GENERAL DESCRIPTION INSTALLATION Electrical power line: External command lines OPERATION Automatic mode Manual mode Emergency mode Shutdown LUMINOUS INDICATORS AND BUTTONS ALARMS AUTOMATIC CALIBRATION OPTIONAL PROGRAMMING Motor in operation Start-up failure Start-up failure controlled by the pump pressure switch Mains underfrequency Mains overfrequency Mains undervoltage Mains voltage present Mains overvoltage Pump overcurrent III
4 10. TIME PROGRAMMING Delayed start after opening of the contacts of the call pressure switches Delayed start after closing of the contact of the priming tank float SETTINGS MADE Pump overcurrent Pump pressure switch function activation ENABLING AUTOMATIC SHUTDOWN ACCORDING TO UNI LANGUAGE SELECTION AUXILIARY FUNCTIONS PARTIAL HOUR COUNTER INSTRUMENT ENABLE/DISABLE RESTORING FACTORY SETTINGS GENERAL CONDITIONS Warranty Maintenance Disposal DECLARATION OF CONFORMITY IV
5 1. INTRODUCTION This manual must always accompany the relevant equipment and be conserved in an accessible location for consultation by qualified technicians assigned for operation and maintenance of the system. The installer/user is strongly recommended to carefully read all instructions and information in this manual before using the product, in order to avoid damage or improper use of the unit, which would also render the warranty null and void. Before operating the equipment, carefully read the manual and follow all instructions provided. The information and instructions in this manual refer to the standard use of this product; in the event of special circumstances, functions or applications not described in this document, contact our service center for assistance. If technical assistance or spare parts are required, when contacting the manufacturer always specify the identification code of the model and construction number as stated on the data plate. Our service center is available for any requirement or clarification. On receipt of the goods, inspect immediately to ensure that the equipment has not been damaged during transport. If defects are found, the client should promptly notify our retailer within 5 days of receiving the goods, or in the event of direct purchases, the Elentek service center. N.B. the information provided in this manual is subject to modifications without notice. The manufacturer shall not be held liable for any damage caused in relation to the use of these instructions, as they are to be considered guideline only. Note that failure to observe the instructions provided in this manual may cause physical injury or damage to objects. In any event all local and/or current legislation must be observed at all times. 5
6 2. WARNINGS The electrical panel must be used exclusively for the purpose and function as specified in design. Any other application or use is to be considered improper and therefore hazardous. In the event of a fire in the place of installation or the surrounding area, avoid the use of water jets and use the appropriate extinguishing equipment and means (powder, foam, carbon dioxide). Install the equipment far from heat sources and in a dry and sheltered location in observance of the stated protection rating (IP). The installation of a safety device is recommended to protect the panel power line in compliance with current electrical standards. The electrical panel must be connected by a qualified electrician in observance of the relevant electrical standards. No parts of the panel must be disassembled without the official authorization of Elentek: any tampering with or modifications to the unit will render all terms of the warranty null and void. All installation and/or maintenance operations must be performed by a specialized technician who is fully aware of the relevant current safety standards. Ensure the installation is connected to an efficient earthing system. After making the electrical connection, check that all electrical panel settings are correct to avoid automatic start-up of the electric pump. Elentek declines all liability in the event of the following: - Incorrect installation; - Use by personnel not adequately trained in the correct use of the panel; - Serious failure to perform scheduled maintenance; - Use of non-original spare parts or parts not specific to the model; - Unauthorized modifications or interventions; - Partial or total failure to observe instructions. 6
7 3. GENERAL DESCRIPTION Power supply 3 ~ 50/60Hz 400V±10%; Low voltage control circuits and inputs; 2 normally closed inputs for control of the start-up pressure switches; Input for command from priming tank; Input for signal from pressure switch to indicate system under pressure/pump off; AUTOMATIC -0-EMERGENCY key selector; Start/Stop buttons for manual test; Control unit led test button; Control unit function menu button; LCD display to show the mains voltage and amperes on 3 phases, Hz, var, watt, volt/amp, cos phi, total and partial hour counter, event log; Display with 5 languages: Italian, English, French, Spanish, German; Indicator leds; Option of operation compliant with UNI10779; Settable delay and alarm functions; Star-Delta timer settable via control unit; Alarm outputs for: availability of electrical power, pump start request, pump running, start-up failure; Electric pump contactors in AC4; Protection of aux. circuits and motor with fuses; Door lock main disconnect switch; Metal enclosure (IP55); Ambient temperature: -5/+40 C; Relative humidity 50% at 40 C (condensate free). 7
8 4. INSTALLATION Ensure that the mains power supply specifications correspond to the voltage specified on the data plate of the electrical panel and motor connected, then make the earthing connection before all other connections. STARDELTA-EN 3~400V ± 10% 50/60Hz The power line must be protected by a residual current circuit breaker. Tighten the electrical cables on the relative terminals using a suitable tool correctly sized to avoid the risk of damage to the fixing screws. Take care if using an electric screwdriver. The electrical panel is designed for wall-mounting using screws and plugs in the pre-drilled holes at the corners of the enclosure, or by means of brackets when present. Install the equipment in areas compliant with the protection rating and ensure that the box is kept intact when drilling the holes for fitting the cable clamps. Avoid the use of multicore cables where there are wires connected to inductive loads and power cables and signal cables such as sensors and digital inputs. Keep connection cables as short as possible, preventing any twisting of cables which may be harmful due to inductive effects on the electronic equipment. All wires used in the cabling must be suitably sized to withstand the load to be powered. 8
9 4.1 Electrical power line: Make the ground connection before all other connections. Ensure that the mains voltage corresponds to the specifications on the electrical panel data plate: Ensure that the power cable is able to withstand 150% of the maximum motor current (according to EN Para ) and connect it to the terminals of the main disconnect switch of the electrical panel. The line must be protected in compliance with current standards. 4.2 External command lines In automatic mode, the electric pump is started via normally closed voltage-free contacts (pressure switches); A normally open voltage-free contact (priming tank float) protects the system against potential dry running conditions; Make the connection with the control panel switched off and the main switch (UPLINE of the panel) turned off, taking care to observe the connections as shown in the attached diagram. 9
10 5. OPERATION This device enables management in AUTOMATIC, MANUAL or EMERGENCY mode of an electric pump in accordance with standards EN When necessary, the electric pump is shut down automatically in a pumping system with exclusive use of the network of hydrants (as envisaged by standard UNI July 2007). When the panel is switched on, the display is activated with a brief general check-up lasting a few seconds, after which the control unit displays the control parameters. When the electrical panel is switched on, the system sets up for AUTOMATIC mode, and only when necessary can be set to MANUAL mode by pressing the START button. The panel is equipped with an AUTOMATIC-EMERGENCY selector with key that can be removed in the AUTOMATIC position, to activate the following operating mode: 5.1 Automatic mode With the key set to AUTOMATIC (the key is removable in this position); otherwise automatic start-up is inhibited, as signalled by the flashing indicator (automatic start-up inhibited) and display of the message: AUT. START-UP INHIBITED. When the control unit detects opening of the starting contact (pressure switches), it starts up the electric pump. The control unit controls (without stopping the pump) any faults on the motor during its operation. Automatic start-up occurs on opening of the contacts on the starting pressure switches, indicated by illumination of the indicator for start-up request from the pressure switches. After any closure of the pressure switches, this indicator starts flashing. Automatic start-up occurs also on closure of the contact of the pump priming float; this is indicated by the steady indicator light. After opening of the contact, the indicator starts flashing. The flashing signals continue for the entire duration of motor operation. 5.2 Manual mode To manually start up the electric pump (useful when testing the system), press the START button of the control unit, taking care that the AUTOMATIC-EMERGENCY selector is set to AUTOMATIC. 10
11 5.3 Emergency mode The system envisages the option of manual start-up in EMERGENCY mode in the event of a fault on the electronic control unit or power supply system to the latter. When the key is set to EMERGENCY, this immediately activates the electric pump control contactor (the motor is started up in DELTA mode) by-passing all electronic controls of the panel. This means that the operator will start up the pump. 5.4 Shutdown The motor can only be shut down manually. It cannot be shut down when there is a request from pressure switches or automatic start-up is enabled. If the pressure switch request is activated even when the stop button is pressed, the electric pump does not shut down and the control unit display shows the message: DO NOT SHUT DOWN IN THE EVENT OF FIRE - SHUTDOWN INHIBITED If the pressure switch request is deactivated when the STOP button is pressed, the electric pump shuts down and the control unit display shows the message: DO NOT SHUT DOWN IN THE EVENT OF FIRE In normal operating mode, the MOTOR RUNNING condition (controlled by the amperometric reading) is indicated by the light which turns on when the pump current remains above the set threshold for the entire duration of the intervention delay. Start-up controlled by the pump pressure switches is indicated by the light and is detected once the motor has started up and the pump pressure switch closes before elapse of the intervention delay. START-UP FAILURE is indicated by the light. After a request for automatic start-up of the motor, the START-UP FAILURE status is detected when the power value (KW) of the pump motor remains below the set threshold for the entire duration of the intervention delay, or when the pump pressure switch does not close and the intervention delay elapses. 11
12 6. LUMINOUS INDICATORS AND BUTTONS The user can scroll through the various values by means of the button. 12
13 7. ALARMS The alarms do not cause shutdown of the pump, but are signalled via the relative indicator, the cumulative led, a message on display, and switch the contact (availability of electrical power) to enable remote monitoring. MOTOR POWER SUPPLY ALARMS: Lack of or drop in mains power, even on a single phase. Incorrect phase sequence or fuses blown. MOTOR ALARM: Overcurrent SYSTEM ALARM: Faults on pressure switch for pump in pressure The alarms can be reset by pressing the button : the safety devices are enabled and the startup cycle is released, controlled by the priming tank float. 13
14 8. AUTOMATIC CALIBRATION Automatic calibration enables automatic programming of the thresholds for PUMP RUNNING and START-UP FAILURE. To perform AUTOMATIC calibration, start up the pump primed with delivery closed: then with the key selector set to AUTOMATIC, press the button. Press and hold the three buttons simultaneously to display the message AUTOMATIC CALIBRATION, and keep pressed until the message PROGRAMMED appears on display. On completion of AUTOMATIC CALIBRATION, the following results are obtained: Programming of the threshold for PUMP RUNNING (controlled by the amperometric reading) for a current equal to half of that delivered with the pump running with delivery closed. The threshold is exceeded when the pump current remains above the set threshold for the entire duration of the intervention (5 seconds). Example: Programming of the threshold for START-UP FAILURE (controlled by the power value KW) for a power equal to 20% less than the power with pump started up with delivery closed. The threshold is exceeded when the power value remains below the set threshold for the entire duration of the intervention (5 seconds). Example: 14
15 9. OPTIONAL PROGRAMMING Located at the rear of the control unit The thresholds can be modified manually according to the procedure described below 9.1 Motor in operation Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button MOTOR IN OPERATION (A) 8.5 A 3 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE 0-100% (MAX 1200A) FACTORY SETTING 8.5A INTERVENTION DELAY 1-10 SEC. FACTORY SETTING 3 SEC. 15
16 9.2 Start-up failure Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button STARTUP FAILURE (KW) 0.1 (KW) 70 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE % (MAX 690KW) FACTORY SETTING BASED ON AUTOMATIC CALIBRATION PAGE 13 INTERVENTION DELAY SEC. FACTORY SETTING 70 SEC. 9.3 Start-up failure controlled by the pump pressure switch Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. STARTUP FAILURE BY PRESS. SWITCH Press button until appears on display. After a few seconds, the display changes automatically and shows user can set the delay threshold using the START and STOP buttons. 70 sec where the Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button and wait for the message PROGRAMMED to appear on display. INTERVENTION DELAY SEC. FACTORY SETTING 70 SEC. 16
17 9.4 Mains underfrequency Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button LINE MAIN UNDERFREQUENCY 46 Hz 2 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE Hz FACTORY SETTING 47.5 (50 Hz) 57 (60 Hz) INTERVENTION DELAY 0-10 SEC. FACTORY SETTING 5 SEC. 9.5 Mains overfrequency Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button LINE MAIN OVERFREQUENCY 60 Hz 2 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE Hz FACTORY SETTING 60 (50 Hz) 72 (60 Hz) INTERVENTION DELAY 0-5 SEC. FACTORY SETTING 2 SEC. 17
18 9.6 Mains undervoltage Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button LINE MAIN UNDERVOLTAGE 356 V 5 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE V FACTORY SETTING 356 V INTERVENTION DELAY SEC. FACTORY SETTING 5 SEC. 9.7 Mains voltage present Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button LINE VOLT. MAIN PRESENT 360 Hz 3 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE V FACTORY SETTING 360 V INTERVENTION DELAY SEC. FACTORY SETTING 5 SEC. 18
19 9.8 Mains overvoltage Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button LINE MAIN OVERVOLTAGE 444 V 4 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE V FACTORY SETTING 444 V INTERVENTION DELAY 1-10 SEC. FACTORY SETTING 3 SEC. 9.9 Pump overcurrent Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. Press button until appears on display. After a few seconds, the display changes automatically and shows with an arrow moving, so that the user can set the threshold and delay using the START and STOP buttons. Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button PUMP OVERCURRENT 50 A 15 sec and wait for the message PROGRAMMED to appear on display. SETTING RANGE 0-100% FACTORY SETTING 50 A INTERVENTION DELAY 1-30 SEC. FACTORY SETTING 15 SEC. 19
20 10. TIME PROGRAMMING 10.1 Delayed start after opening of the contacts of the call pressure switches Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. START DELAY FROM PRESS. SW. Press button until appears on display. After a few seconds, the display changes automatically and shows user can set the delay threshold using the START and STOP buttons. 2 sec where the Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button and wait for the message PROGRAMMED to appear on display. SETTING RANGE 0 10 SEC. FACTORY SETTING 1 SEC. 20
21 10.2 Delayed start after closing of the contact of the priming tank float Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. START DELAY FROM FLOAT Press button until appears on display. After a few seconds, the display changes automatically and shows user can set the delay threshold using the START and STOP buttons. 50 msec where the Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button and wait for the message PROGRAMMED to appear on display. SETTING RANGE 0 10 SEC. FACTORY SETTING 1 SEC. 21
22 11. SETTINGS MADE 11.1 Pump overcurrent On the basis of the panel power, the amp and current transformers are selected and programmed accordingly. The following amp transformer versions can be selected: 30/5, 40/5, 50/5, 60/5, 80/5, 100/5, 200/5, 250/5, 300/5, 400/5, 500/5, 600/5, 800/5, 1000/5. The maximum reading is 1000 A or 110% of the transformer's full scale current. Move to ON lever 1 of the DIP-SWITCH located on the rear of the control unit. AMP TRANSFORMER. 50/5 The display will then show. Use the START and STOP buttons to select the value of the amp transformer. Return lever 1 of the DIP-SWITCH to OFF and within a few seconds, press the button for the message PROGRAMMED to appear on display. and wait Once the Amp T. is programmed, the PUMP OVERCURRENT threshold is set automatically at 100% of the nominal value of the Amp T. (to modify this value manually, see page 19) Pump pressure switch function activation To activate the function PUMP PRESSURE SWITCH, proceed as follows: Move to ON lever 3 of the DIP-SWITCH located on the rear of the control unit. PUMP PRESSURE SWITCH Press the button until appears on display. Return lever 3 of the DIP-SWITCH to OFF and within a few seconds, press the button for the message ENABLED to appear on display. and wait 22
23 12. ENABLING AUTOMATIC SHUTDOWN ACCORDING TO UNI Where deemed necessary, in the case of work not constantly supervised, automatic shutdown is allowed, provided that the pumping system is used exclusively by the hydrant network. To apply the setting for AUTOMATIC SHUTDOWN, remove jumper B from the rear of the control unit. With the jumper removed, and therefore with automatic shutdown enabled, the following appears on display during the start-up test: UNI ON. Operation: The electric pump shuts down 20 minutes after the permanent closure of the starting pressure switches. (The display constantly shows how much time is left before stopping the electric pump). The WAIT TIME can be set for automatic shutdown as required: Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. STOP WAITING TIME Press button until appears on display. After a few seconds, the display changes automatically and shows user can set the delay threshold using the START and STOP buttons. 20 min where the Once the data are set, return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button and wait for the message PROGRAMMED to appear on display. SETTING RANGE 1 30 MIN FACTORY SETTING 20 MIN 23
24 13. LANGUAGE SELECTION The default language is Italian. The languages available are: ENGLISH-SPANISH-GERMAN-FRENCH Move to ON lever 2 of the DIP-SWITCH located on the rear of the control unit. LANGUAGE SELECTED ENGLISH Press button until appears on display. Press the START and STOP buttons to select the language. Return lever 2 of the DIP-SWITCH to OFF and within a few seconds, press the button for the message PROGRAMMED to appear on display. and wait 14. AUXILIARY FUNCTIONS The following REMOTE AUXILIARY FUNCTIONS are available (the table refers to the control unit terminals): These functions are stated on the terminal board of the panel with respect to the terminals: : ELECTRICAL POWER AVAILABILITY (FAULT 9/10 closed); : PUMP START-UP REQUEST (12-14 closed); : PUMP RUNNING (15-17 closed); : START-UP FAILURE (18-20 closed); 24
25 15. PARTIAL HOUR COUNTER To select the PARTIAL HOUR COUNTER, press. This displays the hours and minutes of operation since last activation. The hours displayed are reset on subsequent start-up of the electric pump. 16. INSTRUMENT ENABLE/DISABLE The following instruments can be disabled (all enabled by default): MAINS VOLT METERS, AMMETERS L1 - L3, FREQUENCY METER, WATT METER, VAR METER, VOLT/AMP METER, COS PHI METER. To disable an instrument, proceed as follows: Move to ON lever 3 of the DIP-SWITCH located on the rear of the control unit. AMMETERS L1 L3 Press the button until the instrument to be disabled appears on display. Return lever 3 of the DIP-SWITCH to OFF and within a few seconds, press the button and wait for the message DISABLED to appear on display. To ENABLE an instrument, proceed in the same way until the message ENABLED appears on display. 17. RESTORING FACTORY SETTINGS To restore the factory settings, proceed as follows: Move to ON levers of the DIP-SWITCH located on the rear of the control unit. Press the button for at least 5 seconds until the message STANDARD appears on display. Return all levers of the DIP-SWITCH to OFF. The language selection is not reset. 25
26 18. GENERAL CONDITIONS 18.1 Warranty The product warranty is subject to the general terms of sale of the company Elentek S.r.l. Acknowledgement of the warranty depends on the strict and proven observance of the operating instructions in this booklet and application of the correct mechanical, hydraulic and electro-technical practices. All products are covered by a warranty valid for 12 months, which covers all construction defects of our products and includes the replacement/repairs of defective parts. The warranty will not be deemed valid in the event of: - tampering with the panel (modifications without prior authorisation); - faults due to lack of or inadequate protection and/or connection errors; - faults caused by exceeding data plate specifications; - normal wear and tear of the panel; - failure by installation personnel to observe the specified operating procedures; - accidental causes, natural disasters of any kind, such as fires, flooding or lightning; The defective material must be delivered carriage paid to Elentek S.r.l., who reserves the right to final judgement of the cause of the said defects. The Warranty applies exclusively to restoring the original product characteristics and does not cover material damage or physical injury Maintenance STARDELTA-EN does not require routine maintenance provided that it is used within the operating limits and in observance of the instructions in this manual. Special maintenance or repairs must be performed exclusively by authorised service centres. In the event of repairs, only original spare parts must be used. The manufacturer declines all liability for material damage or injury to persons or animals caused by maintenance interventions performed by unauthorised personnel or using non-original materials Disposal In the event of disassembly and scrapping, strictly observe local legislation regarding pollution. Waste disposal according to material categories is recommended. 26
27 19. DECLARATION OF CONFORMITY ELENTEK Srl with registered offices in via A. Meucci, 5/ Piove di Sacco (PD) ITALIA, declares under its sole responsibility that the machine: STARDELTA-EN series installed and used in the ways and for the purposes described in the operation and instruction manual complies with the provisions of the EU directives and relative amendments: European Directive 2014/35 UE Electromagnetic Compatibility 2014/30 UE and subsequent amendments, in compliance with the following technical standards: EN EN EN EN Piove di Sacco, LEGAL REPRESENTATIVE Michele Borgato 27
28 28 NOTE
29 NOTE 29
30 30 NOTE
31
32 ELENTEK SRL SOCIETÀ UNIPERSONALE Via A. Meucci 5/ Piove di Sacco (PD) - ITALIA Tel Fax info@elentek.com P.IVA Cod. MQ EN 0005 UK Rev. 01 Em
MAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationSKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB
SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured
More informationSOLARIMMERSION IV Advanced Installation Manual v1.9
SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationLCD LCDS LCDRI CONTROLLER OPERATING MANUAL
This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment
More informationInstallation and Operation Manual SPC1
Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE
More informationMasterswitch 25kW 230V-125A Automatic AC transfer switch
INSTALLATION AND USERS MANUAL Masterswitch 25kW 230V-125A Automatic AC transfer switch MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com
More informationQUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12
operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even
More informationProduct Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23
Product Manual ASL Document Ref.: U-0618-0103.doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23 RCS01 RPA Transmitter Charging Station This equipment is designed and manufactured
More informationTT /12b INSTALLATION INSTRUCTIONS. Introduction
TT-1545 11/12b INSTALLATION INSTRUCTIONS Original Issue Date: 6/10 Model: 20-300 kw Generator Sets Market: Industrial Subject: Decision-Maker 3000 Controller Service Replacement Kit GM75376 Introduction
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationInstallation and Operation Manual DPC1
Installation and Operation Manual DPC1 BIA-DPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 6-7 QUICK
More informationDEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description
Description of options Option C1 Generator add-on protection package Multi-line 2 version 2 4189340267E SW version 2.42.X Description of options DEIF A/S Functional description Parameter list DEIF A/S,
More informationORB TM 4-20 ma Input Box Installation & Operation Manual
IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationEnergy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Energy Logger Model EM100 Introduction Congratulations on your purchase
More informationRELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS
RELAY MODULE 9974 INSTALLATION/USE INSTRUCTIONS All connections MUST be made with the electrical supply switched off and the batteries disconnected. GENERAL WARNINGS This manual is intended for technically
More informationDCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies
DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR
More informationSTUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK
STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK The Studio 1800 is a combined Programmer and Temperature Controller which has been specifically designed for use with pottery kilns. Control of
More informationGavita Master Controller EL1
Gavita Master Controller EL1 User manual User manual Gavita Master controller EL1 Dear customer, Congratulations on the purchase of your Gavita Master controller EL1. This manual contains all the information
More informationOperating instructions Safety-monitoring module AES 1235 AES About this document. Content
8 Appendix 8.1 Wiring examples...3 8.2 Integral System Diagnostics (ISD)....4 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101172890-
More informationEWCH 485 Electronic Pulse Counter
Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:
More information(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)
Section 16306 50/60-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER Index PART 1 GENERAL PART 2 PRODUCTS 1.1 References 2.1 Frequency Converters 1.2 Factory Tests 2.2 Conduit and Fittings 1.3 Submittals 2.3
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationSURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B
SURGE PROTECTION PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) USER MANUAL Surge Protection Device B 01 156 9000 This Surge Protection Device is intended for professional use only Read this
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationOperating instructions Safety-monitoring module AES 1235 AES About this document. Content
1. About this document DE Betriebsanleitung...............Seiten 1 bis 6 Übersetzung der Originalbetriebsanleitung 1.1 Function This operating instructions manual provides all the information you need
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationOperating Instructions VEGAMET 381
Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...
More informationSidewinder Pumps Inc. AC C1D2 Timer/Controller
Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------
More informationR & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.
R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationOperating Instructions
TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationINSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer
INSTRUCTION MANUAL Instruction Manual Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance
More informationGSM SECURITY AND CONTROL SYSTEM ESIM021
GSM SECURITY AND CONTROL SYSTEM ESIM021 Manual v1.1 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: Alarm and control system
More informationPower Supply (48Vdc, 2.5A)
Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.
More informationInstallation and operation manual EPIC
Installation and operation manual EPIC Table of contents Cap. Pag. 1 EPIC presentation 4 2 Safety warnings 4 3 Installation 4 4 Technical characteristics 4 5 Electrical connections 5 6 Mains protection
More informationKBMG MULTI-SPEED BOARD
TM INSTALLATION AND OPERATION MANUAL KBMG MULTI-SPEED BOARD KB Part No. 8833 Multi-Speed Board for KBMG Series Regenerative Drive Pending! See Safety Warning on Page 1 The information contained in this
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationOperating Instructions
Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 344A550 Revision 1 2006 Seaward
More informationVSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override
MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override Varifan 3 4 5 6 7 MANUAL 2 8 1 OFF 10 9 AUTO MANUAL SPEED Installation / User s Guide This guide will inform the electrician on proper wiring
More informationElectronic Temperature Controller. Instruction Manual Version
Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found
More informationUSER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230
USER MANUAL VIBRATION CONTROL Version 2.2 1 IMPORTANT NOTES Electrical danger within the meaning of this documentation or the warning labels on the product itself respectively means that death, serious
More informationPump control box without probe
Pump control box without probe Type GUARDIAN User s manual This symbol indicates a potential risk of electrical nature This symbol indicates a subject of particular importance 1.0 OVERVIEW This booklet
More informationOperation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.
Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationOperating Instructions
PRIMETEST 100 PRIMETEST 100 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number
More informationThree-Phase Solar Pump Controller 1.5 kw 380V User Manual
Three-Phase Solar Pump Controller 1.5 kw 380V User Manual Manual Version: SPC3P1.5-380- 2016-1-N Table of Contents 1. IMPORTANT INFORMATION AND SAFETY INSTRUCTIONS... 1 2. INTRODUCTION... 2 2.1 General
More informationControl Unit KEH-P / Force-1.DIN
Translation of the Original Manual Control Unit KEH-P / Force-1.DIN Assembly and Operating Manual Superior Clamping and Gripping Translation of the Original Manual Imprint: Copyright: This manual remains
More informationPhase comparator. User manual Document version: 02i00 Update:
Phase comparator User manual Document version: 02i00 Update: 2015-03-13 Safety information When the device is in operation some of its parts may be connected to a hazardous live voltage. Improper operation
More informationOperating manual Solareg II BASIC
Operating manual Solareg II BASIC Microcontroller-controlled temperature difference controller for solar thermal systems Explanation of the graphic symbols Attention! Symbol indicates possible dangers
More informationOperating instructions Safe AS-i input module ASIM-C-M About this document. Content
7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10
More informationUser's Guide. Model W 3-in-1 Switching DC Power Supply
User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges
More informationCEM M-RS485 INSTRUCTION MANUAL (M014B A)
Communications interface CEM M-RS485 INSTRUCTION MANUAL (M014B01-03-14A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could
More informationPOWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1
POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.
More informationENGLISH. User manual.
ENGLISH User manual Copyright HT ITALIA 2012 Release EN 2.00-18/12/2012 Table of contents: 1. PRECAUTIONS AND SAFETY MEASURES... 2 1.1. Preliminary instructions... 2 1.2. During use... 3 1.3. After use...
More informationExplosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter
Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2
More informationUSER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power
Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland
More informationUser Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at
User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This
More informationSubject Ref. No. Page Alfa-V Dry Coolers IM00003_0808_AM 1/12. Issued by Department Date Menegolo Andrea Product Development
INSTRUCTION MANUAL VOLTAGE REGULATOR FOR TEMPERATURE PROBE (3ph) Subject Ref. No. Page Alfa-V Dry Coolers IM00003_0808_AM 1/12 Issued by Department Date Menegolo Andrea Product Development 05082008 Notes
More informationSidewinder Pumps Inc. AC Timer/Controller
Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationOperation Manual Series W-500
Operation Manual Series W-500 Table of Content 1 Safety information... 2 1.1 Place of application of the unit... 2 1.2 Instructions for installation... 3 2 Start-up and adjustment of controller 4 3 General
More informationMVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions
DIN RAIL ELECTRONIC FAN SPEED Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING
More informationGREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26
H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION
More informationCMSA-100 Manual. Cinema Media Server Automation
CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.
More informationMARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals
Martindale Electric will carry out routine calibration (on a chargeable basis) if the instrument is returned, carriage paid, to the address on the final page of this document. Alternatively, a chargeable
More informationNETRONICS HS3500 CONTROLLER
NETRONICS HS3500 CONTROLLER CUSTOMER NAME CONTROLLER SERIAL # CONTROLLER PART # PERSONALITY SWITCH SETTINGS BULLET PRESS CONFIGURATION DELIVERY DATE Contact the factory for help setting up your application.
More informationInstallation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A
Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationManual Control Unit GFC 32
Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control
More informationQUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!
QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationLine reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation
Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationAUTOMATIC SHORE GENERATOR (INVERTER)- SWITCH OVER UNIT FOR 2 SOURCES LAU 216 (F)
OPERATION MANUAL AUTOMATIC SHORE GENERATOR (INVERTER)- SWITCH OVER UNIT FOR 2 SOURCES LAU 216 (F) INTRODUCTION If an AC generator or inverter is installed on board a yacht or vehicle, it is necessary to
More informationOperating instructions Hinge safety switch TV.S 335 TV.S About this document. Content
1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationGRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2
USER MANUAL MPI-1500/2000/3000/4000/6000 Series GRID-TIED SOLAR INVERTER 1.5KW ~ 6.0KW V.1.2 WWW.MPPSOLAR.COM WARNING: ONLY A CERTIFIED ELECTRICIAN OR TRAINED ASSEMBLING PROFESSIONAL SHOULD OPEN OR INSTALL
More informationDKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY
datakom@datakom.com.tr http://www.datakom.com.tr Tel: +9-216 466 84 6 Fax: +9-216 364 65 65 DKM-45 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY INTRODUCTION The DKM-45 is a low cost precision
More informationOperating Manual RISH DPM Hz
Operating Manual RISH DPM 72mm x 144mm 96mm x 96mm 48mm x 96mm 2-60-006-00-00512_Rev. B - 7/2016 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Digital Panel Meter Installation & Operating Instructions
More informationXBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE
XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...
More informationTVAC25100 TVAC25110 User manual
TVAC25100 TVAC25110 User manual Version 11/2010 Original user manual. Keep for future use. 12 Introduction Dear Customer, Thank you for purchasing this product. This product meets the requirements of the
More informationP216 Series Condenser Fan Speed Controller
P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version
More informationEnglish. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM
English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety
More informationConductive Level Controller
Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment
More informationOperating manual Solareg II BASIC DC
Operating manual Solareg II BASIC DC Microcontroller-controlled temperature difference controller for solar thermal systems Explanation of the graphic symbols Attention! Symbol indicates possible dangers
More information3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE
3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE -ST-01 Page 1 of 10 November 2016 2016 Copyright Lite-On Technology Corporation ALL RIGHTS RESERVED. Lite-On is a trademark of Lite-On Technology
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationM-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES
M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES TABLE OF CONTENTS INTRODUCTION. 2 POWER SUPPLY. 4 INSTRUCTION FOR REPLACING BATTERIES 5 SPECIFICATIONS..
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationOperating Manual -ENGLISH- Page 1 KWG-ISO
Page 1 KWG-ISO Operating manual English- Status May 2013 Page 2 Manufacturer address KW-Generator GmbH & Co.KG Bänglesäcker 24 73527 Schwäbisch-Gmünd / Lindach Phone: +49 (0) 7171 104 17 0 Fax: +49 (0)
More informationPQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES
CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual Q45 230V ac Control panel for electric rolling shutters 230Vac Built-in radio receiver 433Mhz Adjustable pause time for automatic closing function
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationI/O SIGNAL CONDITIONER
Technical Data Sheet No. TD9809M Rev. F Date of Issue: December 9, 2009 OPERATING MANUAL I/O SIGNAL CONDITIONER CAUTION: THIS PRODUCT DOES NOT PROVIDE GALVANIC ISOLATION. DO NOT ATTEMPT USE OF THIS PRODUCT
More informationSD1. Differential Controller. Operating and Installation Instructions F2 72.3
SD1 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety
More informationWise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER
Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER LEN.MAN.STA.111 Rev.4.00/2010 CONTENTS 1. SAFETY INSTRUCTIONS 1 2. INTRODUCTION 2 3. FRONT PANEL AND CONNECTION BOARD 3
More information