SMART BASIC METERS/ TRANSDUCERS/DC ENERGY

Size: px
Start display at page:

Download "SMART BASIC METERS/ TRANSDUCERS/DC ENERGY"

Transcription

1 BASIC CM SMART BASIC METERS/ TRANSDUCERS/DC ENERGY Intertek Contact for certification details Ammeter Voltmeter VAF Meter Meter Frequency Meter DC Meter RPM & MPM BASIC PARAMETERS MEASURED PRECISELY!

2 AMMETER ALPHA+ / µa+ 3A/A Displays VLL, VLN (Avg & PW), F, for Alpha+ 3V & µa+ 3V. VLL for Alpha+ V & µa+ V Field programmable CT primary and secondary. Field programmable PT primary and secondary. Optional programmable relay output (upto 2) for threshold Amp (under or over). True RMS. Four digit resolution with auto scaling. Field programmable Star (Wye) or Delta or Single Phase configuration. ALPHA+ / µa+ 3V/V Displays Amps for Alpha+ A and Amps (Avg & PW) for Alpha+ 3A. Models: Alpha+ 3A & µalpha+ 3A (3 Phase); Alpha+ A & µalpha+ A (single phase). Common Features : VOLT METER Optional transducer output (0 to 20mA / 4 to 20mA or 0 to 1V DC) for average Amps (for Alpha+ series only) Accuracy 1% of FS. Average & Phase wise information. VAF METER Models: Alpha+ 3V & µalpha+ 3V (3 phase measurement); Alpha+ V & µalpha+ V (Single Phase). Optional programmable Relay output (upto 2) for any threshold VLL, (under or over) for A+3V & only VLN (under or over ) for A+ V. Optional transducer output (0 to 20mA / 4 to 20mA or 0 to 1V DC) for Average VLL, VLN and F (for Alpha+ series only) Accuracy 1% of FS. Additional Features: Universal auxiliary input V AC (Optional: V DC, V AC/DC). DC METER Auto-scrolling. Available in single row Dinrail version (Alpha+D VAF, Alpha+D V/3V, Alpha+D A/3A, Alpha+D ). Minimum order quantity apply. Optional direct measurement upto 20A. 60A or 100A max. using Hanging CT. Available in 0.8 inch display (4 digit) - optional (for Alpha+ series only). Minimum order quantity apply. ALPHA+ VAF/3VAF, µa+ VAF Displays Line to Line Voltage -Average and phase wise, Amps - Average and phase wise & Frequency (External selector switch to be used for µalpha+ VAF). Field programmable PT and CT primary and secondary. Optional Features : 2 digital output programmable for threshold upto 6 parameters (Under/Over). Programmable tripping time upto 180 secs. with Hysteresis of 1%. Analog transducer output 0-20mA / 4-20mA or 01V, Accuracy of 1% FS (Alpha+ only). Optional programmable relay output (upto 2) for any threshold VLL avg, A, (under or over). Optional transducer output (0 to 20mA / 4 to 20mA or 0 to 1V DC) for average VLL, VLN, Amps and F (for Alpha+ series only) Accuracy 1% FS. ALPHA+ / µa+ ADC/VDC DC Vin - 75mV or 100mV or 10V or 100V or 500V ma / 4-20 ma input options. 4 digit resolution for ADC. DC auxiliary from V option available for Alpha+ and Dinrail version. Field programmable full scale or offset value. RPM/MPM METER METER Optically isolated RS 485 / RS 232 serial interface (Alpha+ only). VAF METER ALPHA+ / µa+ Displays wider range of frequency Higher accuracy class 0.2. OMEGA 1300 Optional programmable relay output (upto 2) for threshold (under or over). Displays more than 13 basic parameters i.e., VLL, VLN, A (Average & Phase wise), F, ON Hours. Programmable Relay Output (upto 2) {VLL, A, F (under, over)}. Optional transducer output (0 to 20mA / 4 to 20mA or 0 to 1V DC) for (Range 45 to 65) (for Alpha+ series only) Accuracy 1% of FS ALPHA+ / µa+ RPM/MPM DC Vin - 75mV or 100mV or 10V or 100V or 500V ma / 4-20 ma input options. 4 digit resolution for RPM. DC auxiliary supply option of 40 to 300V available. Field programmable full scale or offset value.

3 ALPHA+, µa+ & OMEGA Technical Specification : Specification Class 1 Default as per IEC ,Class 0.5, 0.5S as per IEC Sensing/Measurement: True RMS, 1 Sec update time. Input voltage: 4 Voltage inputs (VR, VY, VB, VN); Programmable 110 or 415V LL Nominal (Range V LL); Primary Programmable up to 999 kv. Burden: 0.2VA Max. per phase Input Current Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A). Primary Programmable up to 99 ka. Overload: 10A max continuous, 50A max for 3 Sec Burden: 0.2VA Max. per phase. TRANSDUCER OUTPUT ElMeasure transducers are programmable transducers (cum display), which converts various applicable electrical parameters like voltage, current, frequency, active power, apparent power, power factor into DC current 0-20mA or 4- Aux-Supply (Control Power): 4digits display with 14 mm height for Alpha Plus, 10 mm height for OMEGA series, µalpha Plus series & DinRail Communication: RS485 serial channel connection, Industry standard Modbus RTU protocol (RS232 optional). Zigbee communication. Baud rate: 4800 bps to bps. (Preferred 9600 bps) Isolation: 2000 Volts AC isolation for 1 minute between communication and other circuits. Weight: Unpacked: 300 gms, Packed: 400 gms 20mA (Programmable) or voltage 0-1V DC Applications are various: electrical, V AC for Omega V AC/DC, Burden: 4VA Max Display: output. chemical, thermal power plants, etc., to Description Accuracy: ECO Friendly Lead Free monitor processed data either locally or 18 Months Warranty Note: Additional error of 0.05% of full scale, for meter input current below 500mA re m o t e l y u s i n g s c a d a s y s t e m by ElMeasure or the third party. Transducer Output Programmable : Accuracy : Class 1.0FS Maximum overload: 120% (Equivalent of 24mA) Sl No Number of output: One (0 to 20mA / 4 to 20mA or 0-1V DC) 1 Any One Output Programmable Transducer Models Alpha+ 3VAF V A V A W VA Output Range Options PF 0-20mA / 4-20mA 0-1V DC Features & Benefits : Programmable primary / secondary voltage or current making wider range of operations - Stocking becomes simple 2 Alpha+ 3V V 0-20mA / 4-20mA 0-1V DC 3 A A Alpha+ 3A 0-20mA / 4-20mA 0-1V DC Programmable transducer output either 0-20mA or 4-20mA. (Maximum load resistance: 75ohms.) 4 Alpha+ 0-20mA / 4-20mA 0-1V DC 0-1V DC optional DC current signal or DC voltage signal directly proportional to the change of input. 5 LG V A W VA PF 0-20mA / 4-20mA 0-1V DC 0-5V DC Fully protected against open and short circuited output. 0-10V DC Product Selection : mm OM 1300 Dinrail* ( mm) Transducer mm OM1310 Parameters VLL, VLN, AMP,, ON Hrs. VLL, VLN, AMP,,PF, ON Hrs, Hi Amps,RPM. ALPHA+ 3VAF VLL, VLN, AMP, ALPHA+ VAF µalpha+ VAF VLN, AMP, (Single Phase) ALPHA+ 3A µalpha+ 3A AMP-Avg, AR, AY, AB ALPHA+ 3V µalpha+ 3V VLL, VLN, Avg & Phase wise, ALPHA+ A µalpha+ A AMP A VOLT V ALPHA+ V µalpha+ V ALPHA+ ADC µalpha+ ADC AMP DC ALPHA+ VDC µalpha+ VDC VOLTS DC ALPHA+ µalpha+ Frequency () ALPHA+ RPM µalpha+ RPM RPM * Dinrail available as per minimum order quantity basis. Note : DC measurement Accuracy Class 1.0FS, Class 0.5FS (optional) In Dinrall version other than RS458, no other option is possible

4 MULTI CHANNEL DC ENERGY METER Common Features : Single meter measures Multiple channels and True RMS measurements. Differential current input for all the current channels. Voltage Full scale programmable. Additional features for EDC 1100 Current full scale programmable independently. Reverse lock option for not accumulating the reverse current energy. This can be used for the better study of charging and discharging circuit. Programmable shunt secondary 50mV to 75mV. Displays V, 1 channel current, 1 channel Watt and 1 channel energy in the bright single row 6 digits. Optional RS485 communication. Energy display programmable-counter based or resolution based. Optional single digital output with the programmable delay. Energy resetting at *PT.Pri*CT Pri. Auto scaling of kilo and mega decimal point. Additional features for EDC 4100 Optional programmable relay output maximum 2 (upto 6 threshold parameters) and tripping time upto 180 seconds. Technical Specification : EDC Displays V, 4 channels Current, 4 channel Watts and energy in the bright single row 6 digits. Optional RS485 communication. Specifica on Descrip on Optional single digital output with the programmable delay. Additional features for EDC 4400 Accuracy: Class 1.0 FS, Class 0.5 FS (optional) Display Resolution: 4Row 6Digits for EDC4400, 1Row 6Digits for EDC4100 and EDC1100. Input voltage: One Input Voltage (48VDC Factory Default). Varieties of range in Voltage like 48VDC, 100VDC, 150VDC, 300VDC,600VDC, 800VDC (factory settable). Primary Programmable range: to 999.9kV. Input Frequency: Input current: One/ Four Input Current (50mV, 75mV Shunt type). Individually Programmable primary current. Range: k. Baud rate: Isolation: Additional features for EDC 4100D LCD display, 7 digit, Din rail version only V AC/DC, Burden: 4VA Nominal. Hall effect CT (100A) Option Rs485 interface Industry Standard Modbus RTU protocol (RS232 optional) bps to bps. (Preferred 9600 bps) volts AC isolation for 1 minute between communication and other circuits. Safety and Environmental Specification Weight: (Approx): Unpacked gms, Shipping gms. Operating Temperature: -10oC to +55oC (14oF to 131oF). Storage Temperature: -25oC to +75oC (-13oF to 581oF). Humidity: 5% to 95% non condensing. Protection index: IP 51 (IP 54 front option). Recommended 12 to 14 SWG. connection wire: ECO Friendly Lead Free 18 Months Warranty Safety: Designed to meet protection class III, pollution degree 2. Protection against shock by double insulation. Clearance and creepage meets as per UL safety standard. Finger touch proof terminals to voltage and current connections Environment: Operating temperature Storage temperature Humidity Protection index Recommended wire gauge -10 C to +55 C (14 F to 131 F) -25 C to +70 C (-13 F to 158 F) 5% to 95% non condensing. IP 51 (IP 54 front option). 12 to 14 SWG. Mechanical Specification: Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel) mm (Depth 45mm behind Bezel) Applicable Standards : DIN EN Degrees of protection provided by enclosure for electrical equipment against ingress of solid foreign objects. DIN / IEC Electrical measuring transducers for converting AC electrical quantities into DC electrical quantities. 90 mm Clamp 92mm IS Electrical measuring transducers for converting AC electrical quantities into DC electrical quantities. Panel Cutout: x mm x mm 44 mm Communication: Optional RS485 communication. Optional two digital output with the programmable delay. 90 mm Aux-Supply: Displays V, 4 channels Current, Watts and Energy. Optional Load Hours (LH) and Amps hours (Ah). Panel Cutout Panel Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/APO/V9/1017 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

5 LGP & MGP CM DIGITAL MULTIFUNCTION LOAD MANAGER Intertek Contact for certification details Basic Power Energy Load Manager Digital Output Pulse Output SIMULTANEOUS MEASUREMENT OF VARIOUS ELECTRICAL PARAMETERS!

6 Features : Accuracy Class 1.0 (default) as per IEC , Class 0.5 as per IEC (Optional). True RMS measurement. Simultaneous sampling of Volts & Amps. Energy display programmable-counter based or resolution based. LG LG µg/dinrail/lcd Energy resetting at kvah* Transformer Ratio Quick and Easy navigation and programming. Positive energy accumulation even with CT polarity reversal, reverse lock programmable. Displays more than 25 parameters Basic, Power and Energy. User programmable password protection. Basic : VLL, VLn, A, (Avg. & PW), F, RPM. Energy is programmable to Wh or VAh with 7 digit resolution (LCD), 6 digit resolution (LED) and 4 digit resolution for instantaneous parameters. Auto scrolling. Power : W, PF, VA, (Avg. & PW) Auto-scaling of Kilo, Mega, Giga and Decimal point. Energy : Wh, Hi. Amps, LH, Wh, LH, ON Time (non resettable). Low PT, CT burden. register to store the previously cleared energy value and its corresponding LH. Front LED pulse 1250 imp/kwh of secondary input. Programmable PT, CT ratio upto 2000 MVA. Programmable kvah (default kwh) for meters with Energy parameter. Wide Measurement range - 10mA - 6A. Clearance and Creepage distance meets safety standard. Displays Basic : VLL, VLn, A (Avg. & PW), F. Power: W, PF,VA (Avg. & PW). Energy : Wh, LH, Old Wh, Old LH. register to store the previously cleared energy value and its corresponding LH. 80 to 300 V AC/DC auxiliary supply. Optional - Programmable relay output (upto 2) for any threshold of Under & Over ( Voltage, Amps, Frequency), Under PF, Over Watts, Over Wh, Phase missing. Optional - Programmable relay output (upto 2 in LCD version and 1 in LG+ 5110) for any threshold of Under & Over(Voltage, Amps, Frequency), Under PF, Over Watts, Over Wh, Phase missing. Programmable tripping time up to 180 sec. with hysteresis of 1%. Programmable tripping time upto 180 sec with hysteresis of 1%. Finger touch proof terminals to voltage and current connections. Parameter name & value displaying using 7 seg LEDs. +3VAF + + LG 1 ADC 1 19 AA W AMPS V - A - DC Wh 6 digits display on each row for better readability. VA PF VAF K Available in LED (3 row, 2 row and 1 row), LCD, Dinrail (1 row). Field programmable Star (Wye) or Delta or Single phase configuration. R REV VLL ALPHA+ LITTLE GENIUS+ LG /LCD, µg Y B VLN PRG A MINUS PRG LG /LCD, µg Optional Features : Communication with PCs, PLCs, DCS through optional optically isolated RS 485/ RS 232 serial Interface. Pulse output - programmable pulse width of 50 ms to 500 ms (for LG plus models only). Programmable Relay output - refer Product Selection Table. Field programmable to Basic (VLL, VLN, A, F) or W or VA or PF or Wh (any two parameters). Factory configured : Wh, PF. Field programmable W or VA or PF or Wh (any one parameter). Factory configured : Wh. Displays programmed parameter name and Displays programmed parameter name and value for instantaneous parameters. value for instantaneous parameters. Reduces complexity of stocking as this can be Reduces complexity of stocking as this can be used for multiple measurement applications. used for multiple measurement applications. register to store the previously cleared register to store the previously cleared energy value. energy value. Note: Also available in dinrail version Application Information: LG+ series has optional optically isolated RS485 or pulse output, which can be integrated into a process through a PLC/DCS for online energy management LG Displays PF, Wh or VAh (programmable), and user selectable parameters from Basic (VLL, VLN, A, ) or W or VA (any 2). Displays more than 15 parameters. For pulse output, if the DCS/PCS has a self excited 12V or 24V, external 24V DC supply is not required. Multiplication factor for counter based energy mode: Full Scale Watts 3 V Pri LL x A Pri 0.4k to 4.0k 4.01k 40.1k 400.1k to to to 40k 400k 4,000k 4M to 40 M 40 M to 400 M 400 M to 4000 M row LED display with 6 digits each. ' register to store the previously cleared energy value. Multiplication Factor: Unit of display Note: No up-gradations and no optional features except RS KWH MWH GWH Energy Reset : kvah Transformer Ratio.

7 Typical Connection Scheme for Dual Energy Measurements DUAL SOURCE ENERGY METER OPTION 1 R AMF PANEL R Y Y B Potential free contact B N LG+5220 / LG+3220 / LG+5120L Grid Power R Y B Source 2 Power N N Common Features MON FEATURES Automatic switching of display based on input source (EB/DG). Load hours and ON hours for both sources. Positive energy accumulation / reverse lock programmable. METER 1 METER N Require only 240V AC as AMF input Programmable to kwh or kvah. ' registers to store the previously cleared energy values. AdditionalFeatures: Features: Additional LG LG LG W VA Wh 2 Row display with 6 digits each. OPTION 2 Simultaneous display of Energy for EB & DG in single page. METER 1 REV DG METER 64 Server METER 2 Gateway Power : W, PF (Avg. & PW). PLC to Ethernet Wireless Non-Dual Source Meter (Zigbee or WiFi) Optional - Programmable relay output upto 2 relays. METER 1 METER 2 METER 64 Options : Under Voltage, Over Voltage, Under Amps, Over Amps, Under Frequency, Over Frequency, Under PF, Over Watts, Over Wh, and Phase missing (both for EB & DG). Programmable tripping time upto 180 sec with hysteresis of 1%. Ethernet to PLC PRG Displays Basic : VLL, VLn, A (Avg. & PW), F. Energy : Wh, LH, ON hrs Wh, LH(both for EB & DG) PF LITTLE GENIUS+ Gateway RS 485 Non-Dual Source Meter PLC Additional LG/ (Single Row) LG Features: ( Two Row 2 Row display with 6 digits each. Simultaneous display of Energy for EB & DG in single page. Technical Specification : Displays W, PF (Average & Phasewise). Specification Wh, Wh, (both for EB & DG) Optional - Programmable relay output upto 2 relays. Accuracy: Class 1 Default as per IEC , Class 0.5 as per IEC Sensing/Measurement: True RMS, 1 Sec update time. 4 Quadrant Power & Energy. Input voltage: 4 Voltage inputs (VR, VY, VB, VN). Programmable 110 or 415V LL Nominal (Range 50 to 550V LL). Primary Programmable up to 999 kv. Burden: 0.2VA Max. per phase. Options : Under PF, Over Watts, Over Wh, and Phase missing (both for EB & DG). Programmable tripping time upto 180 sec with hysteresis of 1%. Input Frequency: Input current: Additional LG+ 5120LFeatures: LG 5120L Energy is programmable to Wh or VAh with 7 digit resolution and 4 digit resolution for instantaneous parameters. Displays Basic : VLL, VLn, A (Avg. & PW), F. Power : W, PF (Avg. & PW). Energy : Wh, LH, ON hrs., Wh, LH (both for EB & DG) Optional - Programmable relay output upto 2 relays. Options : Under & Over (Voltage, Amps, Frequency), Under PF, Over Watts, Over Wh, and Phase missing (both for EB & DG). Programmable tripping time upto 180 sec with hysteresis of 1%. Description Current inputs (AR, AY, AB) 500mA - 6A (Field configurable 1A or 5A). Primary programmable up to 99 ka. Overload: 10A max continuous, 50A max for 3 Sec. Burden: 0.2VA Max. per phase. Aux-Supply: (Control Power) V AC/DC, Burden: 5VA Max Display Type: LG+/µG+: 10mm height bright red LED display. LCD: 10mm height bright LCD. Display Resolution: 4 digits for instantaneous, Integrated: 6digits for LED, 7digits for LCD CT PT Ratio Max: 2000 MVA programmable. Communication: Rs485 serial channel connection, Industry standard Modbus RTU protocol (RS232 optional). Baud rate: 4800 bps to bps. (Preferred 9600bps). Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. Weight: Unpacked: 300 gms, Packed: 400 gms. ECO friendly lead free 18 months warranty Note: Additional error of 0.1% of full scale, for meter input current below 500mA

8 Product Selection Guide : BASIC MODEL NO. POWER ENERGY ACC CLASS ENERGY 1.0/0.5 OPTIONAL FEATURE VLL RYB VLN RYB AMP RYB W RYB PF RYB VA RYB kwh/ kvah LG VLL VLN AMP W PF VA Wh LH & OH 2 LG VLL VLN AMP W PF VA Wh LH 1 LG LG 5220 (DS) # Load Hrs/ ON Hrs Wh VLL VLN AMP + LG 3220 (DS) + LG µg 5110 PF Wh 2 W PF Wh 2 W PF Wh 1 VA LH & OH VLL VLN AMP VLL VLN AMP 1 W PF VA LH Wh + µg µg 1129 µg DIGITAL O/P W LG PULSE O/P RS485 LG LG 1100 RS232 VLL VLN AMP For DinRail Version only RS485 Communication Option Zigbee Communication Option Analog Output # kwh / kvah Programmable at site. LCD / DinRail Version LG+ 5110L VLL VLN AMP W PF VA Wh LH LG+ 5110D VLL VLN AMP W PF VA Wh LH VLL VLN AMP W PF Wh LH + LG 5120L + LG 1119L/D LG+ 1129L/D 2 2 LG+ 3399: Wh and PF any two parameters [Basic (VLL,VLN,AMP,) or W or VA] programmable LG+/µG+ 1119/L/D: Any one parameter [W or PF or VA or Wh] programmable LG+/µG+ 1129/L/D: Any two parameters [Basic (VLL,VLN,AMP,) or W or PF or VA or Wh] programmable Restricted Option Applicable Standards : Safety and Environmental Specification Test of Accuracy requirements IEC Test of electrical requirements IEC Radio interference suppression CISPR22 Fast transient burst test IEC Damped oscillatory waves immunity test IEC Test of immunity to electromagnetic RF fields IEC Test of immunity to conducted disturbances, IEC Induced by radio-frequency fields Test of immunity to electrostatic discharges IEC Surge immunity test IEC Test of the effect of the climatic environments IEC Mechanical tests IEC Test of protection against penetration of dust IEC60529 Safety: Designed to meet protection class III, pollution degree 2. Protection against shock by double insulation. Clearance and Creepage meets as per UL safety standard. Finger touch proof terminals to voltage and current connections. Environment: Operating temperature -10 C to +55 C (14 F to 131 F) Storage temperature -25 C to +70 C (-13 F to 158 F) Humidity 5% to 95% non condensing. Protection index IP 51 (IP 54 front option) Recommended wire gauge 12 to 14 SWG Mechanical Specification: Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel) mm (Depth 45mm behind Bezel) 90 mm and water Test of resistance to heat and fire IEC Safety standard IEC Panel Cutout: x mm x mm Clamp 92mm 44 mm IEC mm Test of insulation properties Panel Cutout Panel Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/LGP/V7/1017 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

9 EN & PN DEMAND CONTROLLER CM Intertek Contact for certification details Multifunction Meter Load Manager Import Export Harmonics Digital/Analog Input or Output K-factor HIGH-END MULTIFUNCTION METER FOR COMPREHENSIVE ENERGY MANAGEMENT!

10 Features: True RMS measurement. Energy kvah Transformer ratio. Simultaneous sampling of Volts & Amps. Reverse lock, user programmable for positive energy accumulation. (Default: No lock) Demand Controller with 1 Relay, 2 Relay & 4 Relay outputs. High / low recording VLL, VLN, A,, W, VA, PF, VAr value storage with time stamp. Front LED pulse imp/kwh. RTC can be adjusted using external communication. Byte order option - Field Programmable Float / Little Endian / Big Endian data format. register to store previously cleared energy & LH values. Upto 60A or 100A direct measurements using Hanging CT. Accuracy class 1.0 as per IEC , 0.5s option). THD for Voltage and Current. % of unbalance V & A for all the phases. User programmable Password Protection. Ampere hour (Ah) and PF average parameters. Auto-Scaling of Kilo, Mega and Giga decimal point. Phase Angle measurement. Neutral Current (calculated), RPM display. Clearance and Creepage distance meets UL Programmable starting current in % of 5A secondary. Default 0.4%. Selectable VA measurement - Vector/Arithmetic/ Vector harmonics. Dual port communication. Demand 1 sec. Ethernet / Zigbee communication. Optional Features EN, PN : Additional Features for PN Digital outputs - 4 potential free contacts with programmable time delay. Hysteresis 1%. Trip time 1 to 180 sec. Programmable. TOD option ( Energy & Demand upto 6 slots ). K-Factor V & A (all three phase). User programmable - Pulse output (POP) on time 50 to 500 msec. Programmable parameter update rate - 1sec. to 5sec. (Default 1sec.). Analog / Digital I/p upto 2. Accuracy class 1% FS Programmable Auto scrolling time - 1 sec. to 10 sec. (Default 5 sec.). Analog Output - Two independently programmable to 0-20 ma (or) 4-20 ma output, configurable to any VLL, A, F, W, PF, VA parameters. Dynamic communication - user selectable register map. Programmable Energy display - Counter based or Resolution based. Individual Harmonics upto 31st order. Datalogger - 1MB / 8MB optional. Features Parameters Basic Line to Neutral Voltage 2 programmable parameters. Phase wise Voltage & Current Wave Forms. LCD 7 parameter display at a time, 7 digit energy. Wave form communication through ELNET Software. Power save mode with Enable/Disable option. PN7700LM EN8400LM PN7710 EN8410 PN7710DMC EN8410DMC Sliding window 2 relay RTC Based RTC Based 4 relay VLN Avg, VR-N, VY-N, VB-N Line to Line Voltage VLL Avg, VR-Y, VY-B, VB-R Line Current A Avg, AR, AY, AB, Neutral Current Computed AN Frequency, RPM (Generator application), RPM V & A Phase Angle VR, VY, VB, AR, AY, AB Unbalance V & A % V, % A, VR, VY, VB, AR, AY, AB Power Active Power W Total, WR, WY, WB Apparent Power VA Total, VAR, VAY, VAB Reactive Power VAR Total, VAR R, VAR Y, VAR B Power Factor PF Avg, PFR, PFY, PFB Energy / Integrated Active Energy Wh Apparent Energy VAh Reactive Energy VARh-Ind, VARh-Cap Load Hrs, No. of Interruption, Life Timer LH, Intr, On.Hr Ah, PF Avg Old (Energy, Load Hrs) Old (Wh, VAh, VARh Ind/Cap, LH, PF, AVG, Ah) Harmonics Voltage THD THD% VR, VY, VB Current THD THD% AR, AY, AB K Factor K Factor: VR, VY, VB, AR, AY, AB Events (High/Low)/ With time stamp Voltage VLL, VLN VLL, VLN Current A Frequency VA VA Watts W VAR VAR Power Factor PF Demand (Optional)* Programmable to any one of the below Active Power (W) Watt Apparent Power (VA) VA Reactive Power (VAR) VAR Current Average (A.Avg) A Avg } Programmable sliding/block, demand period, forcast/ step demand control Control Features (Optional)* Digital Output (Up to 4 relay) Tripping time (1-180 sec) Analog Output / Analog Input Up to 2 Special Features (Optional) Data Logging with Time stamp 1MB/8MB. Refer Table 1 Received/Delivered (Import/Export)/Net Wh, VAh, VArh Ind/Cap,{ PF.Avg, Ah } only Rec & Del, Lh 60A, 100A Direct measurement* 3 Phase (Hanging CT) Individual Harmonics V & A ( All Three Phases ) 31st 31st 31st Communication (Optional)* RS-485 or RS-232 (MODBUS) or Ethernet or Zigbee* Default RS 232 / RS 485 / Ethernet / Zigbee Optional feature - no restriction on combination of options Restricted optional feature - Combination of all restricted options may not be possible in a single product *IndicatesNonUL/ETLproducts LM : Load Manager DMC : Demand Controller

11 Displays all Energy parameters (Wh, VAh, VARh ( Inductive & Capacitive) parameters. Received /Delivered (Import/Export) Energy option. Separate Load hours for Received, Delivered and Net. register to store previously cleared energy values and load hours. Pulse output - Programmable pulse width of 50 ms to 500 ms (Optional). RS 485/232 Optional. EN 8499 Note: This model can be customized for any parameters available in EN 8400LM Key Unique Features Demand Management : Monitoring - Helps to visualise the demand profile during a billing cycle. Harmonics up to 31st level Presence of THD will urge the user to identify Demand peaks with date & time can be identified in the meter as well as the polluting loads and take necessary action ElMeasure's ElNet software. The events can be studied and related with the t o m i t i g a t e h a r m o n i c s t h ro u g h a n production events such as starting of furnace or a large motor etc., and helps to appropriate harmonic filter, save energy to decide on switching/staggering of loads etc. improve plant & equipments efficiency. Control - Enables user to program the threshold values of max demand and Monitors Basic, Power & Energy initiate ALARM/ CUT-OFF when the Forecast Demand/ Present Demand/ Max Parameters Provides the complete spectrum of Electrical Demand surpasses the threshold values. This will help the user from exceeding the sanctioned demand and avoid causing a trip or paying huge penalty. Additional Load - By this feature the user shall be able to decide to transfer the exact quantum of load from EB to DG or vice versa for economic power. system and helps in study of load pattern. Process Integration: Integration of process parameters such as temperature, Oil level, RPM, Pressure etc. giving greater flexibility to monitor them along with electrical parameters. High Low Event Recording for V, A,, VA, W, VAr, PF Protection of 3 phase system against single phasing, low & high voltage, over load, highly lagging and leading PF, etc. Navigator can trap such events for future reference. Identify, record unbalance voltage, currents and helps the user to identify the W VA VLL root cause. Unbalance over-burdens the electrical system and affects in the form of over loading of cables, motors and switchgear. PF Management : Lower the Avg PF higher the system inefficiency. So this enables the user to maintain a healthy PF level. The Digital output features can be used to initiate Control Features: 4 user defined potential free Digital Output based on threshold setting for protection relay for any parameter with programmable trip time to protect the equipments from electrical abnormalities. Power Quality Check/Management: Monitoring phase angle will help the user to identify the causes such as alarm when the Avg PF crosses the user deterioration in the distribution transformers, cables & cable termination, programmed threshold values (Lead/ Lag). presence of harmonics etc. Data Logging with Time Stamp: The information is needed in all types of businesses to determine performance, Cross Verification of Electricity Billing: Helps the user to cross verify with the tariff meter and initiate suitable action if the quality, efficiency, cost reduction, fuel consumption monitoring and many other values have a wide disparity. critical factors. This feature provides important and accurate data for analysis. Digital Outputs : (Up to 4 relay Outputs) 4 User defined potential free relay outputs based on threshold setting. Protection relay for any of Under/Over VLL, A, Over (W, VA, Wh) Under (PF), Phase reversal, Single Phase, Analog inputs. Digital O/P parameters- A.Thd, V.Thd, rev.a, S1 phase, wh.revd, VA, W, under PF, under ( Analog I/P 1, Analog I/P 2, F, A, VLL), over ( Analog Input 1, 2, F, A, VLL)(A.thd, V thd), An In 1 & 2 ( Under & Over), rev A, S1.ph, wh.recd, PF, VA,W, (under & over ) [F,A,VLL] also for RD models, wh.devd. Programmable trip time 1 to 180 sec to suit different load conditions. Rating of control relays: NO contact SPST 2A, 250 VAC / 30 VDC. Typical Applications Automatic connection or disconnection of Gensets connected to common bus. Keep equipment in safe region. Protection of equipment from Under/ Over Voltage or Current or Frequency. Process control. Protection of 3 phase equipment from Single phase prevention, Over load etc.

12 Table 1 nal Optio able m m a Progr ogging L Data No of Parameters 1 Minute to 12 hours interval programmable. Data interval and parameter can be selected through communication. Multiplication factor for counter based energy mode No of Records 1MB 8MB k 4.01k 40.1k 400.1k 4M to to to to to 4.0k 40k 400k 4,000k 40 M Full Scale kw 3 V Pri LL x A Pri / 1000 Multiplication Factor: 0.01 Unit of display KWH M to 400 M 400 M to 4000 M MWH GWH Energy Reset : kvah Transformer ratio Applicable Standards: Technical Specification: Test of insulation properties IEC Test of Accuracy requirements IEC Test of electrical requirements IEC Radio interference suppression CISPR22 Fast transient burst test IEC Sensing/ Measurement: Damped oscillatory waves immunity test IEC Input voltage: Test of immunity to electromagnetic RF fields IEC Test of immunity to conducted disturbances, IEC Specification Induced by radio-frequency fields Accuracy: Class 0.5, 0.5S as per IEC IEC Surge immunity test IEC Test of the effect of the climatic environments IEC True RMS, 1 Sec update time.4 Quadrant Power & Energy (RD Option). 4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL Nominal (Range 80 to 520 VLL) Primary Programmable up to 999 kv. Burden: 0.2VA Max. per phase. Input Frequency: Input current: Test of immunity to electrostatic discharges Description Class 1 Default as per IEC , Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A). Primary Programmable up to 99 ka. Overload: 10A max continuous, 50A max for 3 Sec Burden: 0.2VA Max. per phase. Aux-Supply: Control Power V AC/DC, 40-70, 48V DC (optional) IEC60529 Display Type: Burden: 5VA Max. enavigator: 10mm height bright red LED display Power Navigator: 6mm height bright LCD graphical display. Test of resistance to heat and fire IEC Display Resolution: 4 digits for instantaneous,integrated: EN - 6 digits, PN - 7 digits. Safety standard IEC CT PT Ratio Max: 2000 MVA Programmable. Note : Additional error of 0.1%. IEC Test of protection against penetration of dust and water Communication: Safety and Environmental Specifications: Operating temperature Storage temperature Humidity Protection index Recommended connecting wire ECO friendly lead free -10 C to +55 C (14 F to 131 F) -25 C to +70 C (-13 F to 158 F) 5% to 95% non condensing. IP 51 (IP 54 front option) 12 to 14 SWG with U type lug of 6.75 mm width max. Zigbee communication (Range: 50 meter length) Weight: Unpacked: 300 gms, Packed: 400 gms Mechanical Specification: Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel) Panel Cutout: x mm 90 mm 90 mm Environment: Baud rate: 4800 bps to bps. (Preferred 9600 bps) Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. 96 mm Safety: Designed to meet protection class III, pollution degree 2. Protection against shock by double insulation. Clearance and creepage meets UL safety standard. Finger touch proof terminals to voltage and current connections. Rs485 serial channel connection, Industry standard Modbus RTU protocol (Optional: RS232 / Ethernet / Zigbee). 90 mm Mechanical tests 18 months warranty 50 mm Clamp Panel Panel Cutout Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/NAV/V7/1017 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

13 BM BRANCH CIRCUIT MONITOR Multi Channel Load Manager Cost Saving Compact Design BM SIMULTANEOUS MEASUREMENT OF VARIOUS ELECTRICAL PARAMETERS!

14 Connection Details: BRANCH CIRCUIT MONITOR (BM) The Branch Circuit Monitor (Power Distribution Unit) is ideal in Data center BM 5120 where it can connect and control up to 12 channels of Branch monitoring Controlling can be done using add on Relay unit with Rs485. BM is a meter for 4 measuring Voltage, Current, Power and Energy for every circuit in a power distribution unit or Rack. One can use Split core CTs or Regular CTs to monitor the current in every branch Features: Measures: Multi-channel data collection. Displays more than 25 parameters Basic, Power and Energy. 3 Phase, 4 channels or Single phase 12 channels Displays Basic : VLL, VLn, A (Average & Phasewise), F. Displays Basic, Power and Energy parameters. Power: W, PF,VA (Total & Phasewise). Optional Pluggable Zigbee communication or Ethernet ( Default RS 485). Energy : Wh, LH, VAh, VARh ( PhaseWise for every Channel & Total Channel wise). Space saving compact design for easy installation into existing panel boards. register to store the previously cleared Energy value & LH. True RMS measurements. Specification of Zigbee (coordinator and Router) : Simultaneous sampling of Volts & Amps. Network Support Accuracy class 1.0 as per IEC , Class 0.5 as per IEC User programmable password protection. Energy KVAh Transformer ratio. Note: Customization can be done for other parameters provided volume justify IEEE and Zigbee Data Rates 256 kbps Frequency Band 864 M 865 M (16 channels) with auto scanning Modulation techniques DSSS Wireless Security AES 128-bit encryption Tx Output Power 4.5 dbm Rx Sensitivity -97 dbm Distance covered 20 meters Connection Details: Optional Zigbee Ethernet GPRS Module with memory up to 14 GB A/C Load LMS Data Center Motor/ Pumps Load Solution Architecture : GW 2000D ENERGY MANAGEMENT SOFTWARE BM MODBUS

15 Communication Register Map: Sl No. Parameter Address Data Type Channel 1 Channel 2 Channel 3 Channel 4 1 Watts Total Watts R phase Watts Y phase Watts B phase PF Ave. (Inst.) PF R phase PF Y phase PF B phase VLL average Vry phase Vyb phase Vbr phase VLN average V R phase V Y phase V B phase Current Total Current R phase Current Y phase Current B phase Frequency Wh Received R-Phase Wh Y-Phase Wh B-Phase Wh Load hour Recd Unsigned Long R-Phase load hour Unsigned Long Y-Phase load hour Unsigned Long B-Phase load hour Unsigned Long VAR total VAR R phase VAR Y phase VAR B phase VA total VA R phase VA Y phase VA B phase VAh total VARh IND total VARh CAP total VAh R phase VAh Y phase VAh B phase VARh IND R phase VARh IND Y phase VARh IND B phase VARh CAP R phase VARh CAP Y phase VARh CAP B phase *Optional (26-49)

16 Technical Specification: Applications : Specification For remote reading and control, the BM is supported by ElNet Software, designed for remote setup and data viewing and analysis. Accuracy: Class 1.0 (default) as per IEC , Class 0.5 as per IEC (Optional). Building Management System: With the open modbus protocol, the BM can interface any system, such as building management, HMI etc. Measurement Range: 1:500 for channel 1 & 2, 1:120 for channel 3 & 4 Sensing/ Measurement: True RMS, 1 Sec update time; 4 Quadrant Power & Energy Input voltage: 4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL Nominal (Range 80 to 550V LL) Primary Programmable up to 999 kv. Burden: 0.2VA Max. per phase. Benefits : Compact : Ideal for Data Center. Input Frequency : Ideal for apartments / commercial complexes billing and load pattern study on individual phase. Individual phase kwh measurement provides user flexibility of measuring 3 phase 4 channels or single phase 12 channels. Input current: Current inputs [AR, AY, AB], 4 Channels - Each channel is independently configurable. Primary Programmable up to 99 ka. CT output : Can be upto 1000 mv or 100 ma from Split core CT or Hanging CTs - Manufacturing option. Aux-Supply (Control Power): V AC / DC, Burden: 5VA Max. Display Resolution: 6 digit LED for Energy, 4 digit for Instantaneous Primary current can be independently configured making it ideal for any kind of industry or up-gradation. CT PT Ratio Max: 2000 MVA Programmable. Note: Additional error of 0.1% of full scale, for meter input current below 500mA for 5A setting Current Transformers Description Communication: RS485 interface. Industry standard Modbus RTU protocol. Baud rate: 4800 bps to bps. (Preferred 9600 bps) Isolation : 2000 volts AC isolation for 1 minute between communication and other circuits. Weight:Unpacked: 300 gms Packed: 400 gms Hang on CT- 5A or 50A or 100A Mechanical Specification: Dimension : 90mm * 72mm * 65mm 18 months warranty ECO friendly lead free Safety and Environmental Specification: Safety: Designed to meet protection class III, pollution degree 2.Protection against shock by double insulation. Clearance and Creepage meets as per UL safety standard. Split Core CT-100A 400A 1000A Environment: Operating temperature -10 C to +55 C (14 F to 131 F) Storage temperature -25 C to +70 C (-13 F to 158 F) Humidity 5% to 95% non condensing. Recommended wire gauge 12 to 14 SWG Mechanical Specification: Dimension Bezel : 90 x 90 mm (Depth 67mm) Clip on CT-5A 50A 100A 250A Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/BM/V0/1117 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

17 EPM ENERGY & PROCESS MONITOR Contact for certification details User Friendly Cost Effective Field Programmable DEVICE TO MONITOR PROCESS AND ENERGY TOGETHER!

18 Features : Process Integration: True RMS measurement. Simultaneous sampling of Volts & Amps. Energy display programmable-counter based or resolution based. Energy resetting at kvah Transformer ratio. Positive energy accumulation even with CT polarity reversal, reverse lock programmable. DI Integration of process parameters such as temperature, flow, pressure, RPM, etc. giving greater flexibility to monitor them along with electrical parameters. AI User programmable password protection. Auto scrolling. Auto scaling of Kilo, Mega, Giga and Decimal point. Low PT, CT burden. Displays - Basic: VLL, VLN, A (Avg. & Phase wise), F; Power: W, PF, VA (Avg. & Phase wise); Energy: Wh or VAh programmable (any one), Load hrs, Max & Min ( VLL and Amps), Wh, LH. Front LED pulse imp/kwh of secondary input. Technical Specification: Specification Description Accuracy: Class 1.0 (default) as per IEC , Class 0.5 as per IEC (Optional). Sensing/ Measurement: Input Voltage: True RMS, 1 Sec. update time. 4 Quadrant Power & Energy. Programmable PT, CT ratio upto 2000 MVA. Programmable kvah (default kwh) for meters. Input Frequency: Energy is programmable to Wh or VAh with 6 digit resolution LED and 4 digit resolution for instantaneous parameters. Input Current: 80 to 300 V AC/DC Auxiliary supply. Aux-Supply (control power): 4 Voltage inputs (VR, VY, VB, VN). Programmable 110 or 415V LL Nominal (Range 50 to 550V LL) Primary programmable upto 999 kv. Burden: 0.2VA Max. per phase Current inputs (AR, AY, AB), 500 ma 6A (Field configurable 1A or 5A). Primary programmable upto 99 ka. Overload: 10A max. continuous, 50A max. for 3 sec. Burden: 0.2VA Max. per phase V AC/DC, Burden: 5VA Max. Additional Features: Display resolution: EPM 5110 CT Ratio: High & Low measurements for Voltage and Current (Last one minute of data).mm 2100 Communication: Rs485 serial channel connection, industry standard Modbus RTU protocol (RS232 optional). Baud rate: 4800 bps to bps. (Preferred 9600 bps.) Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. Weight: Unpacked: 300 gms, Packed: 400 gms One Digital input (RPM). Measurement capability up to RPM Displays last one minute RPM. Cumulative RPM through RS digits for Instantaneous, Integrated: 6 digits MVA programmable. 18 months warranty ECO friendly lead free Optional: 2 Analog input for 4 20 ma or 0 20 ma (Flow, Pressure, Temperature, etc.). Mechanical Specification: 3 Digital Input optional. Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel) Intelligent: Clearance and creepage distance meets safety standard. Panel Cutout: x mm Parameter name and value displaying using 7 segment LED's. Field programmable Star (Wye) or Delta or Single phase configuration. 50 mm 90 mm 96 mm Finger touch proof terminals to voltage and current connections. 90 mm 90 mm Clamp Panel Panel Cutout Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/EPM/V0/1117 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

19 iaccl INTELLIGENT AUTOMATIC CHANGEOVER WITH CURRENT LIMITER Current Voltage Frequency Energy FOR A SEAMLESS, UNINTERRUPTED CHANGEOVER BETWEEN POWER SOURCES!

20 40A). Intelligent Overload tripping with AC1 to AC3 behavior V AC LN the system will be ON for DG delay time and OFF for cycle1 time and switches ON once again. If the over current still present, it goes on with cycle 2,3,4,4,4 as per the no. of trip cycles programmed. If the ON / OFF cycle is completed the device trips and permanently disables the output. The reset can be done by pressing the reset key manually Energy (4 digit for single phase), Or through the mobile app when network is available Optional EB Energy and Voltage measurement for 3 phase ACCL iaccl 100 iaccl 32A Upto 40A 100/125A VAC 5-30 sec programmable 5-30 sec programmable Alpha (Tripping based on AC3 behavior) (Din rail option up to 40A) Energy 4 digit 500 gms 90 x 76 x 6 ECO friendly lead free R Y B N 18 months warranty R Y B N PC/IACCL/V3/1017

21 iefr INTELLIGENT Contact for certification details EARTH FAULT RELAY EFR 400 sa SET AMPS 30sA Earth Fault Relay st COM st SET TIME RESET TEST PRG FOR A SEAMLESS, PROTECTION AGAINST EARTH FAULT AND OVER LOAD/EARTH TO NEUTRAL VOLTAGE

22 Unique Features: Features: True RMS measurement. Benefits: Microcontroller based design. Higher technological advantage. Password protection. Helps analysis and corrective action. Common protection for earth fault and over load Current sensitivity wider range 30mA - 5A. Security against mishandling. Clearance and creepage distance meets UL safety standard. Programmable trip time 50ms - 30 sec. No limitations on set current. Inverse curve - trip time is inversely proportional to fault current. This EFR is Intelligent, when the fault current is 10 times higher than the set current, it trips 10 times faster. Field programmable trip current and trip time through front panel keys with password protection. Continuous fault current display (Programmable) - fault current continuously displayed to enhance the user to understand the quality of electrical network / machine online. Selection through soft keys (No DIP switches). Wider choice to suit different industry Continuous earth fault value display. Better IP protection and longer life. Intelligent tripping based on T 1/A or definite time Helps online loss analysis. Auto scrolling of trip Info. & peak fault current. Faster and reliable protection. SMT reflow manufacturing process. Better analysis. Higher reliability. Tripping Characteristics: 10sA Continuous display of trip fault current (Programmable) - In case of tripping, iefr captures and displays the tripped current with 4 digit resolution, which helps the user to analyze and correct the problem. Continuous scrolling display for set current and set time. Wide input range 30mA to 5A and the trip time programmable from 50ms to 30 seconds. Technical Specification: Manual test and reset keys. RS485 communication option. Applications: Protects control panels and switch boards from earth fault. Specification Description Accuracy: Class 2.0FS, Time delay ±5% with minimum of 50 ms. Auxiliary voltage: V AC / DC. Input current: Programmable 30mA - 5A, Over current 30A. Tripping time: Programmable for fault current, 30 MA to SA Setting ranges: Low-set (I >) : 0.05A to 5.0A Low-set time (kt >) : 0.05, 0.1, 0.2, 0.3, 0.5, 1.0, 2.0,..., 30 sec. High-set (I >>) : 0.1A to 30A or disable. High-set delay time (t >>) : 0.05 sec. to 30 sec. Relay contacts: Two pair of potential free NO & NC contacts. One part to EFR 200D Contact Rating: 2 or 4 240V AC / 24V DC. Mounting Type: Flush or Dinrail Communication: Rs485 serial channel connection industry standard Modbus RTU protocol. Baud rate: 4800 bps to bps. (Preferred 9600 bps). Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. Protects motors / transformers / feeders / generators etc., from earth fault. Hazardous and sensitive industries like oil refineries / pulp industries / electrical distribution etc., can be protected. ECO friendly lead free 18 months warranty Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/IEFR/V1/1017 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

23 ielr INTELLIGENT Contact for certification details EARTH LEAKAGE RELAY Earth leakage current Trip time DETECT THE LEAKAGE CURRENT IN AN INTELLIGENT ELECTRICAL DEVICE!

24 Unique Features: Features: Benefits: True RMS measurement. Microcontroller based design. Higher technological advantage. Clearance and creepage distance meets UL safety standard. Peak detection and value display. Helps analysis and corrective action. Password protection. Security against mishandling. Current sensitivity wider range 300mA - 12A. No limitations on set current. Inverse curve - trip time is inversely proportional to fault current. This ELR is Intelligent, when the leakage current is 10 times higher than the set current, it trips 10 times faster. Programmable trip time 300ms - 30 sec. Wider choice to suit different industry Selection through soft keys (No DIP switches). Better IP protection and longer life. Field programmable trip current and trip time through front panel keys with password protection. Continuous Earth Leakage Value Display Programmable ). Helps online loss analysis. Continuous leakage current display (Programmable) Leakage current continuously displayed to enhance the user to understand the quality of Electrical network / Machine online. This can be disabled through setup if required. Auto scrolling of trip Info. & peak fault current. Better analysis. SMT reflow manufacturing process. Higher reliability. Continuous display of trip leakage current (Programmable) In case of tripping, ielr captures and displays the tripped current with 4 digit resolution, which helps the user to analyze and correct the problem. This can be disabled through setup if required. Intelligent tripping based on T 1/A Faster and reliable protection. Tripping Characteristics: 10sA Continuous scrolling display for set current and set time. Wide input range 300mA to 12A and the trip time programmable from 300 ms to 30 seconds (Optional 30 ma - 1A). Manual test and reset keys. Technical Specification: RS485 communication option. Specification Description Accuracy: Class 2.0FS for dimension upto 200mm, Class 5.0 FS above 200mm Protects control panels and switch boards from flame leakage. Input voltage: V AC / DC. Input Frequency: Protects motors / transformers / feeders / generators etc., from earth leakage. Input current: Programmable 300mA - 12A. Tripping time: Programmable 0.3 sec to 30 sec (Optional 30 ma - 1A). Hazardous and sensitive industries like oil refineries / pulp industries / electrical distribution etc., can be protected. Core Balance: CT type : tape wound CBCT: Round - tape wound (Epoxy dipped option), Rectangular - tape wound. Applications: Complete protection for control engineering and mining industry. Core Balance Current Transformer - CBCT CBCT Specification Relay contacts: One pair of potential free NO & NC contacts. Contact Rating: 240V AC / 24V DC. Mounting Type: Flush. Communication: RS 485 serial channel connection industry standard Modbus RTU protocol. Baud rate: 4800 bps to bps. (Preferred 9600 bps). Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. Input Range : 300mA to 12A Default, 30mA - 1.0A (Optional) CBCT: Tape Wound Round Diameter: Inner Diameter 40mm, 60mm, 100mm, 150mm, 200mm, 250mm, 300mm Rectangular: mm, mm, mm, Mechanical Specification: mm, mm, mm, mm, mm. (Any other sizes subject to availability) Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel) Panel Cutout: x mm ECO friendly lead free 18 months warranty 50 mm 90 mm 90 mm 96 mm 90 mm Panel Cutout Clamp Panel Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/IELR/V7/1017 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

25 MPS & MPU MOTOR PROTECTION SYSTEM Contact for certification details Voltage Overload Frequency PF Single phasing Unbalance loading of voltage and current Neutral current Phase reversal. MPS 8000 MPU LG TRIP TRIP V - A - - W - VA - PF - Wh ALARM UNSAFE SAFE TRIP TRIP TRIP SAFE REV TRIP PRG RESET CLR PRG T1 T1 RESET MOTOR PROTECTION SYSTEM MOTOR PROTECTION UNIT ONE STOP SOLUTION FOR MOTOR PROTECTION!

26 Common Features: Technical Specification: User programmable password protection. Specification Auto-scaling of Kilo, Mega, Giga and decimal point. Accuracy: Auto scrolling. Description Class 1.0 (default) as per IEC , Class 0.5 as per IEC (Optional). Finger touch proof terminals for voltage and current connections. Sensing/ Measurement: Input Voltage: Clearance & creepage distance meets UL safety standard. Communication with PCs, PLCs, DCS through optional RS 485/232 serial interface. True RMS, 1 Sec update time. 4 Voltage inputs (VR, VY, VB, VN); Programmable 110 or 415V LL Nominal (Range V LL)Primary Programmable up to 999 kv Burden: 0.2VA Max. per phase. Input Frequency: Input Current: Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A) Primary Programmable up to 99 ka Overload: 10A max continuous, 50A max for 3 sec. Burden: 0.2VA Max. per phase. Aux-Supply (Control Power): V AC/DC. (control power): Potential free output with programmable trip time for protection. Displays more than 25 parameters Basic (VLL, VLN, A, ); Power (W, VA, PF) and Energy (kw, Load Hours). Displays the reasons for tripping for future correction. Programmable start time from sensing safe condition. CT PT Ratio Max: 2000 MVA Programmable. Communication: Rs485 serial interface Industry standard Modbus RTU protocol (RS232 optional) Baud rate: 4800 bps to bps. (Preferred 9600 bps) Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. Weight: Unpacked: 300 gms, Packed: 400 gms Programmable locked rotor current and time. Additional Features for MPS 8000: Displays ON hours, Load hours & number of interruption. Simultaneous display of 7 parameters. Intelligent power save mode. Two field configurable parameter for continuous display. 18 months warranty ECO friendly lead free Continuous Wh display even in Auto-scrolling mode. Graphical display. Parameters can be configured and its range : Neutral current display and protection. Parameters Default Setup Default Setup Range MPU 5110 MPS 8000 Single solutions for protection of motors/equipment against voltage, overload, frequency, PF, single phasing, unbalance loading of voltage and current, neutral current, & phase reversal. Programmable (intelligent inverse time) trip time for Volts/Overload//PF/Neutral current. Programmable relay status High or Low for safe; 2 relays for alarm and trip. Connection mode(elemnt) STAR STAR PT Primary (PT.Pri) STAR/ DELTA 100V - 999kV PT Secondary (PT SEC) V - 550V CT Primary (CT.Pri) A - 99kA CT Secondary (CT SEC) A - 6A VA selection (UA.SLEC) Arith (Arithmetic) Vec.H (Vector) Over Voltage Line to Line Arith(Arithmetic)/Vector vec.h(vector harmonics) kV Under Voltage Line to Line kV Measures VLL, VLN, A,, W, VA, PF, Neutral current, Wh, Load hours, ON hours, No. of interruption. Under Current (Dry Run) NA 0-99kA Over Current kA Operational diagram for MPS & MPU Over Frequency NA Under Frequency NA Under PF NA PF Percentage Voltage Unbalance NA 7.000% % Detect winding shorts. Safe/Alarm/Trip indication for on line view. Manual re-correction after the trip. Parameter like under/over Volts, Amps, Frequency, PF, Unbalance loading of Voltage/Current, Neutral current, Single phasing MPS 8000 Intelligent tripping based on load Off time OFF TIME Variable Load Pattern SAFE REGION TRIP Alarm Relay for Warning Start Delay Programmable Programmable Relay Status UNSAFE REGION TRIP Time 7.000% % NA kA ON Delay Sec OFF Delay Sec RELAY ON Motor ON safe status NA Locked Rotor Current 6 time fixed (not programmable) 1-999kA REL ON/ OFF 1-60 Sec Off time Start Delay Programmable Parameter like under/over Volts, Amps, Dry run, Single phasing MPU 5110 Percentage Current Unbalance NA Neutral Current OFF TIME Variable Load Pattern UNSAFE REGION SAFE REGION TRIP TRIP Locked Rotor Time Delay NA 5.00 Winding Short NA 10% 5-90% Over Current Digital Output Characteristics Absolute INV CUrV INV CUrV/Absolute Poles NA Poles Reverse Lock No No NO / YES Time Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/MPS/V5/1017 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

27 id - LOG PORTABLE POWER ANALYSER CUM DATA LOGGER USER FRIENDLY DYNAMIC COMMUNICATION DEMAND MONITORING High Profile Portable Power Analyzer with Higher Accuracy and Data logging

28 id LOGGER ElNet Portable Power Analyser with Dynamic Communication, Higher Accuracy and Data Logging Energy Management Software The Software collects data from the plant Kit - 1 Kit - 2 id LOG - Ethernet 4GB data logger (default) Option for current measurement using Clip CT (default) or Rogowski consolidating it into manageable information to constantly monitor energy usage and identify the core areas for corrective action, ensuring optimum performance. id LOG - Ethernet & GPRS 14GB data logger (default) 24/7 CLOUD SERVER Web based technology User friendly Enhanced security Vector based graphics Remote monitor and control equipment processes and facilities with in-expensive web browsers Report on operational status of equipment, process and facilities Reduce billing cycles by obtaining accounting information directly from automation systems Reduce service calls and manpower by using remote diagnostics. Use low cost secure connections to network over a combination if ISP, Intranet, Internet and dial-up connections Internet Features Helps you to locate, predict, prevent and troubleshoot problems in power distribution. Measures voltage, current, frequency, power, energy consumption, unbalance, harmonics and inter-harmonics. 24x7 Cloud Server Data logging with Time stamp Monitor and Control large campuses or remote facilities with inexpensive web technology Perform audits and analyses remotely. Analyzing and Reporting DATA LOGGER OPTION BASIC POWER ENERGY A variety of reports can be availed by activity, schedule and types by specific list: Data Quality Exception Reports Alarm Handling Packages Display Groups Historical Data Trending Real time Trending Dashboard Matrix id-log 7700 Benefits Maximum Return on Investments Reduce Energy Costs Improve Working Environment Identification and elimination of energy waste Security and System Integration Various Protocol Supported Economically priced High Performance and Easy configuration Applications Frontline troubleshooting Predictive maintenance Quality of service compliance Long-term analysis Load studies Energy assessments Reports can be viable and downloaded by any format provided and schedules can be modified based on convenient time. *Schedulers will automatically run according to our initial configuration Portability Compact Size Modular Construction LCD Screen Inbuilt GPRS Communication Datalog Trends - Single and multiple days Min, Max & Avg. Table view - Single and multiple days Data Export to Excel Alarm, Min & Max. /SMS Day Log book, Hourly-day Energy, Shift Energy, TOD energy, Min max, Flexible energy report and for abnormal Alarm conditions SMS to the mobile for the following: abnormal Alarm conditions, Hourly and Daily Energy Customization is possible for any kind of /SMS options

29 Features Parameters Basic Line to Neutral Voltage Line to Line Voltage Line Current Neutral Current Computed Frequency, RPM (Generator application) V & A Phase Angle Unbalance V & A Power Active Power Apparent Power Reactive Power Power Factor Energy / Integrated Active Energy Apparent Energy Reactive Energy Load Hrs, No. of Interruption, Life Timer Old (Energy, Load Hrs) Harmonics Voltage THD Current THD K Factor Individual Harmonics Events (High/Low)/ With time stamp Voltage VLL, VLN High/Low Current High/Low Frequency High/Low VA High/Low W High/Low VAR High/Low Power Factor High/Low Demand Active Power (W) Apparent Power (VA) Reactive Power (VAR) Current Average (A.Avg) VLN Avg,VR-N,VY-N,VB-N VLL Avg,VR-Y,VY-B,VB-R AR, AY, AB, A-avg AN, RPM VR, VY, VB, AR, AY, AB % V, % A, VR, VY, VB, AR, AY, AB W Total, WR, WY, WB VA Total, VAR, VAY, VAB VAR Total, VAR R, VAR Y, VAR B PF Avg, PFR, PFY, PFB Wh VAh VARh-Ind, VARh-Cap LH, Intr, On.Hr Ah, PF Avg Old (Wh, VAh, VARh Ind/Cap, LH) THD% VR, VY, VB THD% AR, AY, AB K Factor: VR, VY, VB, AR, AY, AB Upto 31st (V & A) Technical Specifica on: Specifica on Descrip on Accuracy: Class 1 (Default) IEC , Class 0.2 with specific CT. Sensing/ Measurement: True RMS, 1 Sec update time.4 Quadrant Power & Energy Input voltage: 4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL Nominal (Range 80 to 520 VLL) Primary Programmable up to 999 kv. Burden: 0.2VA Max. per phase. Input frequency: 45 to 65 Input current: Current inputs (333mV) Primary Programmable up to 99 ka. Burden: 0.2VA Max. per phase. Aux-Supply: Built-in Display Type: 6mm height bright LCD graphical display. Display Resolution: 7 digits. CT PT Ratio Max: 2000 MVA Programmable. Communication: GPRS / Ethernet VLL, VLN A VA W VAR PF Programmable to any one of the below Watt Programmable sliding/ VA fixed window, block demand period, forcast/ VAR step demand control A Avg } CT Specification Suitable to measure current from ma to hundreds of ka. High linearity Wide range Non-intrusive, no power drawn from the main. Very useful with large size or awkward shaped conductors or in places with limited access. No danger from open-circuited secondary Not damaged by large overloads. Clip CT Rogowski coil Rated Current: 100A ~ 100 ka Output: 0.333V or 100mV per 1000A Diameter: 24 cm, 36 cm Lead wire: 1.5 m length Isolation voltage: 3500V Temperature range: -25oC + 70oC Response bandwidth: 1 ~ 1M 333 mv Input current 250A Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI MUMBAI DELHI HYDERABAD USA UAE ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I: Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T:

30 ipfc INTELLIGENT Contact for certification details POWER FACTOR CONTROLLER Current Voltage Frequency PF VAR 6/8/12 stage control INTELLIGENT DEVICE TO MAINTAIN THE POWER FACTOR IN REQUIRED RANGE

31 Features: Connection Scheme: LOAD Three phase sensing. RS 485 Intelligent Power Factor Controlling based on the capacitor bank switching history (Number of operations, ON time) improves the capacitor life time. 6 or 8 or 12 switching relay outputs. A U X COM ALARM 1 COM N VB VY VR S1 S2 AB S1 S2 AY S1 RY BN S1 S2 User programmable: - Star/Delta. - Lead and Lag limits. - PT and CT ratios. - CT secondary. - Minimum switch ON time (4-999 seconds). - Minimum discharge time (4-999 seconds). - Minimum capacitor on time (4-999 seconds). - Minimum sensing current for controlling operation 100mA - 500mA. - User programmable capacitor value. AR Automatic or manual control (manual control with power backup option). S2 S1 S2 S1 LINE S2 DELIVERED RECEIVED LOAD Technical Specification: Specification Description Accuracy: Class 1.0 (default) as per IEC , Class 0.5 as per IEC (Optional). True RMS, 1 Sec update time. 4 Quadrant Power & Energy. Sensing/ Measurement: Input voltage: Fault detection (Over compensation, Under compensation, Over voltage, Over current, Under voltage, Under current, Over harmonics for voltage and current). Displays VLL, VLN, Amps (Average and Phasewise) Frequency, W, PF, VAR(Total and Phasewise) Wh,PF Avg. 4 Voltage inputs (VR, VY, VB, VN) Programmable 110 or 415V LL Nominal (Range 80 to 550V LL) Primary Programmable up to 999 kv. Burden: 0.2VA Max. per phase. Input Frequency: Input current: Current inputs (AR, AY, AB) 50mA - 6A (Field configurable 1A or 5A). Primary Programmable up to 99 ka. Overload: 10A max continuous, 50A max for 3 Sec. Burden: 0.2VA Max. per phase. (Control Power): V AC/DC, Burden: 10VA Max. Four quadrant operation. RS 485 communication interface (Optional). Aux-Supply : Applications: In all Incomers. Display Resolution: CT PT Ratio Max: 1 row, 6 digits, (Integrated 6 digits) 10mm. Communication: Master to PC. RS485 serial channel connection, Industry standard Modbus RTU protocol (RS232 optional). Baud rate: 4800 bps to bps (Preferred 9600 bps). Isolation: 2000 volts AC isolation for 1 minute between communication and other circuits. Contact rating: SPST, 240V. Weight: Unpacked: 350 gms, Packed: 450 gms MVA Programmable. Fixed power factor corrections individual (e.g. motor, transformers, lighting, etc.) Group fixed power factor correction (several equipments connected in a group). Capacitor banks of tuned and detuned. Harmonic trap applications (e.g. UPS, Frequency Drives and Converters, etc.) 18 months warranty ECO friendly lead free Note: Additional error of 0.1% of full scale, for meter input current below 500mA Advantages Mechanical Specification: Dimension Bezel: 96 x 96 mm (Depth 50mm behind Bezel) Three phase sensing gives accurate measurement of PF. Increased capacitor life - capacitor switching based on history - ON time / number of switching. 90 mm 96 mm Automatic or Manual Control (manual control with power backup option). 90 mm 90 mm Fault Detection (Over compensation, Under compensation, Over voltage, Over current, Under voltage, Under Current, Over harmonics for voltage and current). Clamp Panel 50 mm Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE Unit-II: Unit-III: Plot No.: 47-P, Hardware Park, KIADB, Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Goutham Garden, No. 4, Veerapandi, Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com #764, 4th Phase, 707, Yelahanka New Town, Bengaluru Karnataka INDIA T: PC/IPCF/V6/1017 ELMEASURE INDIA PRIVATE LIMITED HO & Unit-I:

32 SMART I/O SMART INPUT & OUTPUT MODULE Universal Input Universal Output Digital Output SMARTEST WAY TO CAPTURE THE INPUT & COMMUNICATE DATA OUTPUT!

33 Features: Technical Specification: Up to 8 Universal Inputs field configurable Up to 4 Universal Outputs field configurable 6 SSR outputs and 2 relay outputs (optional) Communication LON / RS 485 Fire resistant enclosure Pluggable terminal blocks, for installation wiring and ease of maintenance Specification Description Voltage 13-28VAC, 50 / 60, 12-36V DC Consumption 1A max Protection Under voltage, over voltage (Max 40V), over current, reverse voltage Accuracy Class Universal Input Digital Ordering Information : UI / DI Models Available SIO SIO SIO SIO A SIO B DI 24V 16DI PFC UO DO DO8 AUX1 + DO7 AUX2 DO8 + DO6 DO7 DO6 COM6 COM5 + DO V AC/DC Digital Output B LON+ A LON- B LON+ + - GND A LON- UI8 COM COM + G UI-CH8 UI6 UI7 UI-CH7 UI-CH6 UI5 COM COM UI-CH5 UI4 COM COM UI-CH4 UI3 UI2 UI-CH2 UI-CH3 UI1 COM 4 to 20 ma, 0 to 20 ma factory set for loop powered RTD PT 100 (2 wire ) + 1% + 1% C C - Thermistor Thermistor 10K (Type 2) (Type 3 Optional) User defined Non standard 10K Potentiometer -> temperature curve up to 60 points, user configurable transition table up to 16 points 0 or 12VDC, 60mA, RL 200 ohm Voltage 0 to 10 VDC Current 4 to 20 ma, 0 to 20 ma (optional) PWM Configurable period seconds (programmable on time and duty) One Shot Pulse Configurable pulse width 100 ms to 1000 ms 2-8 SSR output (Configurable only at factory) AUX Universal Input COM Current 2/4 Universal Output (configurable only at factory) COM7-8 + DO4 DO5 DO4 + DO3 COM4 DO3 COM3 DO2 COM2 DO1 COM1 UO-CH4 UO-COM G OP UO4 UO-CH3 UO-CH2 UO2 UO3 UO-CH1 UO-COM G OP UO1 + DO2 Universal Output UI-CH1 0 to 5V, 0 to 10 VDC Digital Wiring Diagram: + DO1 5V to 24V Voltage Digital (Dry/Wet Contact) 0 OR PWM Configurable period seconds One Shot Pulse Configurable pulse width 100 ms ms Communication Configuration Software Lon Talk TP/FT - 10 Mod Bus RS 485 Isolation RS KV, LON - Polarity free Mechanical Poly Carbonate Enclosure Flammability class UL94-V0 (non-flammable) Dimensions 145x90x 45(LxBXH) Mounting DIN rail / wall mounting Weight 300 gm Environmental Operating Temperature -10 C to +55 C Storage Temperature -25 C to +70 C Relative humidity 5 to 95 % (Non-condensing) IP 51 Connector Compliance 2 Part pluggable LONMARK CE Mark 18 months warranty ECO friendly lead free 18 months warranty Pump Fan G OP G OP UO2 UO3 UO4 UO1 VAV s + DO1 + DO2 + DO3 Universal Output + DO4 + DO5 + DO6 + DO7 + DO V AC/DC Lighting Chiller AUX Digital Output A/C LON Boiler UI6 UI7 UI8 COM COM UI5 UI2 UI3 UI4 COM COM UI1 Universal Input G + A B A B MODBUS CO2 CO2 Pressure Sensor Flow Sensor Level Sensor Humidity Sensor Occupancy Sensor Range of Products: Building Energy Management System (BEMS) EMS Demand Controller Multifunction Meters Electronic Energy Meters Dual Energy Meter Digital Panel Meters Automatic Changeover with Current Limiter (ACCL) Power Factor Controller (PFC) Earth Leakage Relay (ELR) Earth Fault Relay (EFR) Gateway Branch Monitoring Unit Smart Input Output Transducers Converters Sales Offices: BANGALORE CHENNAI COIMBATORE MUMBAI DELHI HYDERABAD USA UAE POWER CORPORATION ELMEASURE INDIA PRIVATE LIMITED 302 Mayu Tower, Nr. Shyamal Row Houses, Satellite, Ahmedabad Unit-II: Unit-III: rudresh@powercorporation.in, powercorporation1@gmail.com, powercorporation@yahoo.com Plot No.: 47-P, Hardware Park, KIADB, Goutham Garden, No. 4, Veerapandi, #764, 4th Phase, 707, Yelahanka New Town, website: Mobile: Huvinayakanahalli, Jala Hobli, Yelahanka Taluk, Bengaluru Karnataka INDIA. Coimbatore Tamilnadu INDIA T: TF: E: contactcbe@elmeasure.com Bengaluru Karnataka INDIA T: PC/SI-O/V3/1017 HO & Unit-I:

34 POWER CORPORATION 302 Mayu Tower, Nr. Shyamal Row Houses, Satellite, Ahmedabad website: Mobile:

EM6400 series Multi-Function meters

EM6400 series Multi-Function meters 6400 series Multi-Function meters 1 Digital display & Analog load bar indicators 2 Bright Red LED display 3 Global: CE, UL marks 4 Universal Demand Monitoring Quick and easy installation Turbo Key 6400

More information

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet PowerLogic power-monitoring units power meter Technical data sheet Distributed By: MetersUSA www.metersusa.com Meters@MetersUSA.com 1 224 365 5935 Basic energy meters Functions and characteristics PB105460

More information

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet PowerLogic power-monitoring units power meter Technical data sheet 2011 Basic energy meters Functions and characteristics PE86261 PE86260 PowerLogic PM1000 power meter. The PowerLogic power meters are

More information

NP 8710 NAVIGATOR PRO. Comprehensive monitoring of essential power,energy demand and power quality.

NP 8710 NAVIGATOR PRO. Comprehensive monitoring of essential power,energy demand and power quality. NP 8710 NAVIGATOR PRO Comprehensive monitoring of essential power,energy demand and power quality. Monitors power quality parameters 1s capturing of Sag & Swell with waveforms High accuracy of Class 0.2S

More information

Digital Multifunction Meters. Digital Multifunction Meters

Digital Multifunction Meters. Digital Multifunction Meters Digital Multifunction Meters Digital Multifunction Meters DIGITAL MULTIFUNCTIOL METERS SECTION INDEX 1. MFM 3410 3420 3430 3440 6100 & 2000 - Multifunctional Instrument Series 2. EM 3490, 3490SS, 3490DS

More information

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet PowerLogic power-monitoring units digital panel meters Technical data sheet 2011 Authorized Distributor: WESCHLER INSTRUMENTS phone: 800-903-9870 440-378-6580 fax: 800-903-9590 440-238-0660 www.weschler.com

More information

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters Power and Energy Meters Code No. LIT-1900845 Issued December 4, 2013 EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters EM-1000 Series Meter Description The EM-1000 Series monitor is

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low

More information

TNY Series-Multifunction Panel Meter

TNY Series-Multifunction Panel Meter PROCOM TNY Series-Multifunction Panel Meter Rev.-01 TNY Series-Multifunction Panel Meter 1. Introduction : INDEX 2. Features : 3. Model Selection : 4. Specification : 5. Integer Flow : 6. Auxiliary Supply

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

PMC 530 Series Advanced Multifunction Meter

PMC 530 Series Advanced Multifunction Meter IEC 62053 22 Class 0.5S WF Capture @ 128 samples/cycle WF and Data Recording Harmonics & Transient Monitoring I residual Monitoring Setpoint Alarms, SOE Log RS 485 and I/O Capabilities Large, Bright, Backlit

More information

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications Multilin EPM 6100 Energy and Demand Submeter with Wi-Fi The EPM 6100 is a powerful tool that allows customers to monitor and manage their energy usage within factories, businesses and across campuses.

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

PMC-630 Series Advanced Multifunction Meter

PMC-630 Series Advanced Multifunction Meter IEC 62053-22 Class 0.5S Compliant 2MB Log Memory Power Quality Monitoring Waveform Recording SOE Log Setpoint Alarms RS-485 and I/O Capabilities I residual Monitoring Large, Bright, Backlit LCD Display

More information

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016 Interface Definition RISH EM 2340/1320/30/40 1 2-60-006-00-00494_Rev. D - 8/2016 2 Section DIGITAL MULTIFUNCTION INSTRUMENT Contents 1. Introduction Programmable Multi-function Energy Meter Installation

More information

Metering Devices IQ 300

Metering Devices IQ 300 Effective: May 2001 Page 1 New Information Contents Description Page General Description......... 2 Specifications.............. 3 Field Wiring Connections.... 4 Page 2 Effective: May 2001 Applications

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES Multilin EPM 6010 BUILDING AUTOMATION POWER METER BACnet /IP Communications and Energy Measurement KEY BENEFITS Rapid integration into BACnet management systems High accuracy multifunction power meter,

More information

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators

NewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators NewCode Comprehensive Motor Protection and Control Relay Relay Field Input and Output LEDs LED Fault Indicators Configurable Memory Module on a T-Bus IrDA and USB Connectors Profibus Address Indicator

More information

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

Electronic Submeter with Advanced WiFi Ethernet Capability

Electronic Submeter with Advanced WiFi Ethernet Capability SH RK 100S Electronic Submeter with Advanced WiFi Ethernet Capability AGGRESSIVE TECHNOLOGY W NEIndustry Leading Technology High Performance Metering Technology 0.2% Accuracy Class Revenue Certifiable

More information

POWER METER HC Features

POWER METER HC Features Introduction The power quality meter HC 6030 is an ideal device to power monitoring in power quality when continuous monitoring to a power system is required. The HC 6030 provides metering for current,

More information

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation MultiCube Single Phase Multi-Function Electricity Meter Installation and Operation PREFACE MultiCube Single Phase Meter Operating Guide Revision 5.01 August 2002 This manual represents your meter as manufactured

More information

USER S MANUAL. XPERT Electrical Power Meter. Trinity Energy Systems Pvt. Ltd. TRINITY. Xpert Operational Manual

USER S MANUAL. XPERT Electrical Power Meter. Trinity Energy Systems Pvt. Ltd. TRINITY. Xpert Operational Manual USER S MANUAL XPERT Electrical Power Meter This document contains the latest technical information about Xpert which is a microcontroller based Electrical Power Meter. The product Xpert is sophisticated

More information

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,

More information

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES ACUREV 1310 Three-Phased DIN-Rail Multifunction Meter FEATURES Revenue grade accuracy: ANSI C12.20 0.5 Class Measurement Canada approved Tamper-proof sealing design approved for revenue applications Wide

More information

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus

More information

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter TOU SMART ENERGY METER SATEC is a Smart DIN Rail TOU Energy Meter. It is based on SATEC s best seller PM130 PLUS with an off-theshelf LCD display (similar to the BFM136 display). The provides the full

More information

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017 163C Single-Phase Multifunction Meter User Manual Version: V1 August 20, 2017 This manual may not be reproduced in whole or in part by any means without the express written permission from IPD. The information

More information

LE ELECTRONICS Pvt. Ltd.

LE ELECTRONICS Pvt. Ltd. LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

USER MANUAL 2012 V1.1

USER MANUAL 2012 V1.1 SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information

More information

Acuvim L Series. Multifunction Power Meters FEATURES

Acuvim L Series. Multifunction Power Meters FEATURES Acuvim L Series Multifunction Power Meters TRUE-RMS MEASURING OVER/UNDER LIMIT ALARM MAX & MIN RECORD POWER QUALITY ANALYSIS TOU,4 TARIFFS, 12 SEASONS 14 SCHEDULES Metering of Distribution Feeders, Transformers,

More information

Energy Management Solutions

Energy Management Solutions Energy Management Solutions Power Generation and Transmission Facilities You can provide solution in your Power transmission project with Klea Energy Analyser and Systemon Software Shopping Malls and Chain

More information

FP-5000 Feeder Protection

FP-5000 Feeder Protection Effective: April 2001 Page 1 New Information FP-00 Feeder Protection Contents Description Page FP-00 Description......... 2 Application Description...... 2 Features, Functions and Benefits..............

More information

MW/MVAR Transducer Specifications

MW/MVAR Transducer Specifications GUARANTEED TECHNICAL PARTICULARS (To be submitted by bidder with the tender) MW/MVAR Transducer Specifications Sr.No. Descriptions Details Offered by supplier 1 2 3 4 Transducer suitable for Input Output

More information

Voltage Transducer UMT516 / MT516

Voltage Transducer UMT516 / MT516 Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication

More information

Technical Specifications. Dual Source Energy Meter (EB / DG)

Technical Specifications. Dual Source Energy Meter (EB / DG) Technical Specifications of Dual Source Energy Meter (EB / DG) (SPMG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com

More information

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values CT/VT Interface 560CVT10 The fault current is measured up to 20 times nominal current. Therefore the current inputs withstand 50 times nominal current for 1 s. The CT/VT interface is equipped with one

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

02/11/2015

02/11/2015 DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

SUBJECT TO CHANGE WITHOUT NOTICE

SUBJECT TO CHANGE WITHOUT NOTICE 100A DIRECT CONNECTED (MID CERTIFIED) AP25-3DO www.sifamtinsley.co.uk NEW PRODUCT Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

A2000 Multifunctional Power Meter

A2000 Multifunctional Power Meter 3-348-980-03 3/12.99 Capable of communications via Profibus-DP, LONWORKS interface or RS 485 interface (depending upon model) Measurement of current, voltage, active, reactive and apparent power, power

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96 Class 1 (active energy) Class 2 (reactive energy) Accuracy 0.5% RDG (current/voltage) Universal utility meter and power

More information

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight

More information

NEW Industry Leading Technology. Includes Modbus and DNP 3.0 A G G R E S S I V E T E C H N O L O G Y. High End Meter Performance

NEW Industry Leading Technology. Includes Modbus and DNP 3.0 A G G R E S S I V E T E C H N O L O G Y. High End Meter Performance Includes Modbus and DNP 3.0 Shark 100T Transducer Only NEW Industry Leading Technology High End Meter Performance Low End Economical Pricing Our Easiest to Use Meter Ever! Shark 100 Meter/Transducer A

More information

Technical Specifications. Dual Source kwh Energy Meter

Technical Specifications. Dual Source kwh Energy Meter Technical Specifications of Dual Source kwh Energy Meter (SPKG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email

More information

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter Contents Description Page Product overview.... 2 Key features.... 2 Wide voltage range.... 2 Ordering information... 2 Additional features.... 2 functions comparison... 3 Metering.... 4 Specifications....

More information

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300 Monitoring Technique VARIMETER PRO Multifunction Measuring Relay MK 93N, MH 93 268581 Product description MK 93N MH 93 The universal measuring relays MK 93N / MH 93 of the VARIMETER PRO series monitor

More information

RISH Master 3440i/3440iDL 0.2S

RISH Master 3440i/3440iDL 0.2S Interface Definition RISH Master 344i/344iDL.2S as per IEC6253-22 DIGITAL MULTIFUNCTION INSTRUMENT Installation & Operating Instructions Section 1. 2. 3. 4. 5. Contents Introduction Communication selection

More information

UW Purchase Specification Section

UW Purchase Specification Section Page 1 of 9 PART 2 GENERAL 2.01 DESCRIPTION A. Purpose 1. This section covers electrical service meters and sub-meters for use in the Owner's power distribution systems. 2.02 QUALIFICATIONS A. Approved

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

AcuRev Multi-Circuit Power and Energy Meter.   Shop for Accuenergy products online at: AcuRev 2000 Multi-Circuit Power and Energy Meter ISO9001 Certified Comply to IEC 62053-21 Measurement Standard Support up to 18 Individual Channels for Energy Measurement Multifunction Power Metering,

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights BRANCH FEEDER MONITOR SATEC s is the second generation of Branch Feeder Monitor, providing energy management for multi-point power solutions. Ideal for both new and retrofit projects, the automatically

More information

with Backlight Graphic LCD Screen

with Backlight Graphic LCD Screen with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of

More information

!"!#$!%&'()!%*+,-%./0/123&&45&

!!#$!%&'()!%*+,-%./0/123&&45& !"!#$!%&'()!%*+,-%./0/123&&45& Real Time Metering Email Data-Logging TOU Max & Min Record ISO9001 Certified DESCRIPTION The is a high-end multifunction power meter manufactured by Accuenergy. It is the

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

METERING INSTRUMENTS AND CURRENT TRANSFORMERS Energy Meters p16-1 Data Concentrators p16-3 Digital Measuring Instruments p16-4 Expansion Modules and Accessories p16-15 Current Transformers p16-19 Software and Applications p16-22 Systems Management

More information

Bus Bar Protection Relay B-PRO 4000

Bus Bar Protection Relay B-PRO 4000 Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

FU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications

FU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications FU2200B 0-800V Ethernet Power Meter with Data Logger FU2200B is a three-phase multifunction power and energy meter manufactured by GFUVE. The meter provide excellent value for monitoring power and energy

More information

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter PM130 PLUS POWER METER The PM130 PLUS is a compact, multi-function, three-phase AC powermeter specially designed to meet the requirements of users ranging from electrical panel builders to substation operators.

More information

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering GE Grid Solutions Multilin EPM 6010 Building Automation Power Meter with BacNET /IP Communications The Multilin EPM 6010 is an industry leading revenue grade power meter with native BACnet/ IP communications.

More information

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1. SDM630 Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 203 V. Important Safety Information is contained in the Maintenance section. Familiarize yourself with this

More information

Technical Specifications. Multi Function Meter

Technical Specifications. Multi Function Meter Technical Specifications of Multi Function Meter (SPM300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com

More information

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt Smart Energy & Power Quality Solutions UMG 505 Power analysis, LON and I/O-Vielfalt UMG 505 UMG 505 Power analysis, LON and I/O-Vielfalt Power analysers of the UMG505 product family are mainly designed

More information

08/07/2015

08/07/2015 DIN Rail Mount 22.5 mm TUR1 Part number 88865105 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2 Quick Start Guide EM132-133 Mechanical Installation Figure 1: Instrument Dimensions 2 Mechanical Installation Figure 2: Mounting the EM133 on DIN Rail or on flat surface IMPORTANT! Only qualified personnel

More information

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

AcquiSuite Ally 48 Advanced Branch Circuit Monitor AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition

More information

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.

More information

INTEGRA DIGITAL METERING SYSTEMS

INTEGRA DIGITAL METERING SYSTEMS CROMPTON INSTRUMENTS INTEGRA DIGITAL METERING SYSTEMS INTEGRA DIGITAL METERING SYSTEMS The Integra digital metering product portfolio offers an extensive range of systems designed to suit any power monitoring

More information

DC541 Digital Input/Output Module

DC541 Digital Input/Output Module Ordering Data DATA SHEET DC541 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 270 000 R0001 1SAP 470 000 R0001 DC541-CM, digital input/output module,

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

Protection Relays PHASE & RESIDUAL OVERCURRENT

Protection Relays PHASE & RESIDUAL OVERCURRENT Protection Relays PHASE & RESIDUAL OVERCURRENT Application The relay type NA016 can be used in radial networks as feeder or power transformer protection. In solidly grounded systems the residual overcurrent

More information

Monitoring various parameters with one power meter!

Monitoring various parameters with one power meter! Eco-POWER METER KW2M SERIES Conforming to EMC Directive Monitoring various parameters with one power meter! Equipped with multi functionalities and two ports * *UL61010-1:2012 CAN/CSA-C22.2 No.61010-1-12

More information

RT4F-48V/50A-WAC RECTIFIER

RT4F-48V/50A-WAC RECTIFIER The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been

More information

Energy Management Energy Transducer Type ET112

Energy Management Energy Transducer Type ET112 Energy Management Energy Transducer Type Single phase energy transducer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement

More information

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

DKM-407 DIN RAIL TYPE NETWORK ANALYZER DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution

More information

EngyVolt RV12 and RV15

EngyVolt RV12 and RV15 Technical Information EngyVolt RV12 and RV15 Multifunctional electrical energy meters for top-hat rail installation or panel mounting Application For measuring voltage, frequency, current, power, as well

More information

Technical Specificaions. kwh Energy Meter

Technical Specificaions. kwh Energy Meter Technical Specificaions of kwh Energy Meter (SPK301) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com

More information

CI542 PROFIBUS Communication Interface Module

CI542 PROFIBUS Communication Interface Module Ordering Data DATA SHEET CI542 PROFIBUS Communication Interface Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 224 200 R0001 1SAP 424 200 R0001 CI542-DP, PROFIBUS DP bus module,

More information

DI561 Digital Input Module

DI561 Digital Input Module Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital

More information

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems SDM630M CT DIN Rail Energy Meter for Single and Three Phase Electrical Systems Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc. Bi-directional measurement IMP & EXP Two pulse outputs

More information

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL MICROPROCESSOR PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL MICROELETTRICA SCIENTIFICA MANUFACTURES A COMPLETE RANGE OF

More information

RT4B-110V/12A RECTIFIER

RT4B-110V/12A RECTIFIER The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs

More information

MINER-S Station Controller

MINER-S Station Controller MINER-S Station Controller Substation Automation MINER-S Station Controller The MINER-S Station Controller is a SCADA enabled fixed point remote terminal unit (RTU) with a data concentrator, event reporter,

More information

DC522 Digital Input/Output Module

DC522 Digital Input/Output Module Ordering Data DATA SHEET DC522 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 240 600 R0001 1SAP 440 600 R0001 DC522, digital input/output module, 16

More information

DIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG

DIGITAL TEMPERATURE MONITOR MASTERTEMP ANSI I CATALOG CATALOG INTRODUCTION The temperature monitor MASTERTEMP was developed to monitor oil and winding temperatures in transformers and reactors immersed in oil. It features also the activation of cooling fans

More information

Operating Manual RISH DPM Hz

Operating Manual RISH DPM Hz Operating Manual RISH DPM 72mm x 144mm 96mm x 96mm 48mm x 96mm 2-60-006-00-00512_Rev. B - 7/2016 DIGITAL MULTIFUNCTION INSTRUMENT Programmable Digital Panel Meter Installation & Operating Instructions

More information