IFC Controller WX USER GUIDE

Size: px
Start display at page:

Download "IFC Controller WX USER GUIDE"

Transcription

1 PN D1 IFC Controller WX USER GUIDE

2 For Research Use Only. Not for use in diagnostic procedures. Information in this publication is subject to change without notice. It is Fluidigm policy to improve products as new techniques and components become available. Therefore, Fluidigm reserves the right to change specifications at any time. Every effort has been made to avoid errors in the text, diagrams, illustrations, figures, and screen captures. However, Fluidigm assumes no responsibility for any errors or omissions. In no event shall Fluidigm be liable for any damages in connection with or arising from the use of this publication. Patent and Limited License Information Fluidigm products are covered by issued and pending patents in the United States and other countries. Patent and limited license information is available at fluidigm.com/legalnotices Limited Use License to Perform Pre-Amplification with Fluidigm IFCs The purchase of IFCs from Fluidigm Corporation conveys to the purchaser the limited, non-transferable right to perform pre-amplification methods under license from Life Technologies Corporation for use with the purchased amount of this product and Fluidigm instruments. No right to resell this product and no other rights (such as real-time PCR methods, apparatus, reagents or software to perform digital PCR methods) are conveyed by Life Technologies Corporation expressly, by implication, or by estoppel. For information on obtaining additional rights, please contact or Out Licensing, Life Technologies, 5791 Van Allen Way, Carlsbad, California For information about the scope of the above-identified Fields, please contact Limited Digital PCR License A license to use Life Technologies Corporation's patented digital PCR method in all fields other than in the Sequencing Field, the Mass Spectrometry Field and the Prenatal Field in workflows involving a Fluidigm Digital Array IFC can be obtained by (i) with purchase of a Fluidigm Digital Array IFC from Fluidigm Corporation or (ii) by a separate license from Life Technologies Corporation. For licensing information, please contact outlicensing@lifetech.com or Out Licensing, Life Technologies, 5791 Van Allen Way, Carlsbad, California Trademarks Fluidigm, the Fluidigm logo, Access Array, Biomark, EP1, Digital Array, Dynamic Array, FC1, Flex Six, MSL, NanoFlex, qdpcr 37K, SNP Type, and Delta Gene are trademarks or registered trademarks of Fluidigm Corporation in the United States and/or other countries. All other trademarks are the sole property of their respective owners. For EU's WEEE directive information, go to fluidigm.com/compliance 2015 Fluidigm Corporation. All rights reserved. 05/2015 For technical support visit fluidigm.com/support United States techsupport@fluidigm.com Europe techsupporteurope@fluidigm.com Asia techsupportasia@fluidigm.com Latin America techsupportlatam@fluidigm.com All other countries techsupport@fluidigm.com PHONE United States (toll-free) Europe Japan China (excluding Hong Kong) All other countries

3 Contents About This Guide 5 How to Use This Guide 5 Safety Alert Conventions 5 Safety Alerts for Chemicals 5 Safety Alerts for Instruments 6 Safety Data Sheets 6 Related Documents 7 Chapter 1: Introducing IFC Controller WX 8 Components of the IFC Controller WX 9 Workflow for Reusable IFCs 10 Process Overview 11 Technical Specifications 11 Operating Environment 11 Noise Level 11 Regulatory Compliance 11 Power Options 12 Barcode Labeling 12 Chapter 2: IFC Controller Basics 13 Start the IFC Controller 13 Load an IFC 14 Run Scripts 15 Chapter 3: Using the IFC Controller Software 17 Log In 17 User Tools 18 Administrator Tools 19 Edit User 19 Change Settings 20 Operating in Group Mode 21 Clean System (manually) 24 Network Settings 24 Manage Users 25 Export Logs 27 Change Time/Date 27 Manage Scripts 28 Log Out 28 Update Software and Scripts 29 Install Updated Software and Scripts 29 Load New Scripts 30 Appendix A: Troubleshooting and Maintenance 32 Observation and Possible Course of Action 32 Clean the IFC Controller 33 Clean the Interface Plate 33 Clean the System 35 Manually Clean the System 36 Fuse Replacement 38 Appendix B: IFC Controller Site Requirements and Setup 40 Site Requirements 40 Proper Grounding/Protective Earth Connection 40 Electrical Requirements 40 Uninterruptible Power Supply 41 Workspace 41 Electrical Connection 42 Unpack the IFC Controller 43 Install the IFC Controller 43 Connect the Power Cable 44 Power On the IFC Controller 44 Appendix C: Safety 45 General Safety 45 3

4 Contents Instrument Safety 45 Instrument Symbols 46 Chemical Safety 47 Disposal of Products 47 4

5 About This Guide CAUTION ABBREVIATED SAFETY ALERTS. Hazard symbols and hazard types specified in procedures may be abbreviated in this document. For complete safety information, see the safety appendix on page 53. How to Use This Guide This user guide provides information about setup, installation, operation, and maintenance of the IFC controller. In this document, the term controller refers to the IFC controller and the term software refers to the IFC controller software. Safety Alert Conventions This guide uses specific conventions for presenting information that may require your attention. Refer to the following safety alert conventions. Safety Alerts for Chemicals Fluidigm follows the United Nations Globally Harmonized System (GHS) for communicating chemical hazard information. GHS provides a common means of classifying chemical hazards and a standardized approach to chemical label elements and safety data sheets (SDSs). Key elements include: Pictograms that consist of a symbol on a white background within a red diamondshaped frame. Refer to the individual SDS for the applicable pictograms and warnings pertaining to the chemicals being used. Signal words that alert the user to a potential hazard and indicate the severity level. The signal words used for chemical hazards under GHS: DANGER Indicates more severe hazards. WARNING Indicates less severe hazards. 5

6 About This Guide Safety Data Sheets Safety Alerts for Instruments For hazards associated with instruments, this guide uses the following indicators: Pictograms that consist of a symbol on a white background within a black triangleshaped frame. Signal words that alert the user to a potential hazard and indicate the severity level. The signal words used for instrument hazards: DANGER Indicates an imminent hazard that will result in severe injury or death if not avoided. WARNING Indicates a potentially hazardous situation that could result in serious injury or death. CAUTION Indicates a potentially hazardous situation that could result in minor or moderate personal injury. IMPORTANT Indicates information necessary for proper use of products or successful outcome of experiments. Safety Data Sheets Read and understand the SDSs before handling chemicals. To obtain SDSs for chemicals ordered from Fluidigm Corporation, either alone or as part of this system, go to fluidigm.com/sds and search for the SDS using either the product name or the part number. Some chemicals referred to in this user guide may not have been provided with your system. Obtain the SDSs for chemicals provided by other manufacturers from those manufacturers. 6

7 About This Guide Related Documents Related Documents This document is intended to be used in conjunction with these related documents: Document Title Part Number Biomark HD Data Collection User Guide Biomark/EP1 Data Collection User Guide SNP Genotyping Analysis User Guide Genotyping with the FR48.48 IFC Using SNP Type Assays Genotyping with the FR48.48 IFC Using Standard TaqMan Assays Cleaning the FR48.48 IFC (Wash and Bake)

8 Chapter 1: Introducing IFC Controller WX IFC controller WX is a compact single-bay instrument that employs pneumatic pressure to precisely meter samples and reagents and to control valves within the FR48.48 Dynamic Array integrated fluidic circuit (IFC). The IFC controller can control and apply pressures to different sealing zones on the IFC input/output frame to enable: Metering of liquids from inlet positions in the input frame to reaction chambers within the IFC Metering of liquids within the IFC Opening and closing of valves within the IFC IFC controller WX has a heated anvil in the IFC tray that allows liquids to evaporate from IFC wells when purge scripts are run. CAUTION Be careful not to touch the heated anvil after a purge script has been run or if a purge script is aborted. The anvil is normally not hot enough to cause injury, but if the IFC is ejected during a purge script, the anvil may be as hot as 90 ºC. Heated anvil Hot surface hazard symbol Warning message after purge This user guide walks you through: Key features and benefits of IFC controller WX Installation and setup procedures Description of system functions NOTE IFC controller WX is for research use only and is not for use in diagnostic procedures. 8

9 Chapter 1: Introducing IFC Controller WX Components of the IFC Controller WX Components of the IFC Controller WX LCD touchscreen Interface plate Reusable IFC Tray Figure 1. Front of IFC controller On/off switch Power cord input socket Fuse label Networking ports USB port Figure 2. Back of IFC controller 9

10 Chapter1:Introducing IFC Controller WX Workflow for Reusable IFCs Component Purpose Quantity IFC controller Controls filling of reagents and valve actuation in IFCs 1 Removable interface plate Power cable IFC controller WX User Guide Interface between IFC and IFC controller with pressure inlet ports Country-specific power cable to connect IFC controller to wall socket Describes in detail how to install and use the IFC controller Fuse Spare fuse based on country voltage 2 Removable interface plate O-rings Spares for use if an O-ring is lost during cleaning of interface plate 4 NOTE To order additional items, contact Fluidigm sales. For phone or contact information, go to fluidigm.com/contact Workflow for Reusable IFCs Equipment required: 2 IFC controller WXs: one for loading only and one for washing only FC1 cycler for fast thermal cycling EP1 for end-point SNP genotyping runs Lab Companion convection oven for drying reusable IFCs The workflow is illustrated in the process below. he EP1 1 Prime the FR48.48 IFC in the Load-only WX 2 Prepare assays, sample pre-mix and samples 3 Load the FR48.48 IFC in the Load-only WX. 4 Thermal cycle the FR48.48 IFC in FC1 cycler 5 Collect data on EP1 6 Clean the FR48.48 IFC in the Clean-only WX 7 Dry the FR48.48 IFC in the convection oven For more information, see the SNP Genotyping Analysis User Guide (PN ). 10

11 Chapter 1: Introducing IFC Controller WX Process Overview Process Overview Stop Reuse IFCs Yes No PCR 5? Wash 1 Wash 2 New IFC Prime Load Bake dry Purge Technical Specifications Electrical input voltage of the IFC Controller WX is VAC, 2.7A, 50/60Hz. Operating Environment IFC controller WX should be used in an environment that meets the following requirements. IMPORTANT The IFC controller is for indoor use only. Temperature Ambient between 20 ºC and 30 ºC Humidity 30% 80%, noncondensing Pollution Degree 2 Electrical Installation Altitude Category II Up to 2,000 m Noise Level The operation of IFC Controller WX emits a noise level of 64 db. Regulatory Compliance IFC controller WX is CE compliant for laboratory equipment and electrical safety. 11

12 Chapter1:Introducing IFC Controller WX Power Options Power Options IFC controller WX operates through V AC power at 50/60 Hz. Barcode Labeling Labels on the IFC contain the Fluidigm logo, a unique 10-character number, and a one-dimensional, Code 128 barcode. You can use this barcode with the provided integrated barcode reader to track samples and experiments. 12

13 Chapter 2: IFC Controller Basics This chapter describes how to use IFC controller WX. IMPORTANT To set up the IFC controller, read the site requirements and installation instructions in Appendix B: IFC Controller Site Requirements and Setup on page 40. CAUTION LIFTING HAZARD. The IFC controller is shipped in one cardboard box containing the controller, power cables, and spare fuses. It weighs 59 lb (27 kg). Use caution when moving the shipping box. Start the IFC Controller 1 Turn on the switch on the back of the IFC controller. On/off switch 2 The LCD display lights up. After seconds the initialization screen appears. The IFC controller software starts and initializes all system components. After initialization, the instrument runs an internal health check. In the event an error occurs, contact technical support for service. For phone or contact information, see page 2. 13

14 Chapter2:IFC Controller Basics Load an IFC Load an IFC For more information about using the software, see Chapter 3: Using the IFC Controller Software. 1 At completion of power-up and instrument initialization, the Home screen appears. You may log in now or later. See Log In on page Press Eject to move the tray out of the IFC controller. 3 Place the IFC onto the tray by aligning its notched corner to the A1 mark. Remove and discard the blue protective film from the bottom of the IFC, if you have not already done so. A1 mark Notched corner on IFC 4 Press Load Chip to register the IFC barcode and activate script selection. 14

15 Chapter2:IFC Controller Basics Run Scripts Run Scripts 1 Choose a script to run from the script selection window. The list of available scripts is defined by the IFC barcode. This example uses Prime (168x). IFC icon and barcode Load Mix (168x) If prompted to log in, see Log In on page Press Run Script. Prime (168x) 3 A status screen appears with a time estimate for completion. Pressing Abort during an active script will cancel the run. 15

16 Chapter2:IFC Controller Basics Run Scripts When the script has successfully completed, a dialog box alerts you that the script is completed and displays an Eject button. 4 Press Eject to move the IFC out of the controller. 5 You may now pipet into the IFC. 6 Return the IFC to the IFC controller WX. 7 Run the appropriate script to introduce samples and primers into the IFC and to clean the IFC. (168x) 16

17 Chapter 3: Using the IFC Controller Software Log In 1 Press Login at the bottom right of the screen. 2 Log in as Admin or User. When entering a password for the first time: If you are logging in as Admin, the initial default password is: If you are logging on as User, there is no initial default password. For more information, see Manage Users on page

18 Chapter 3: Using the IFC Controller Software User Tools User Tools 1 Press Tools at the bottom right of the screen. When logged in as User, these tools are available: Edit User. Allows you to change your password. Settings. Allows you to enable full logging for this session. If this option is selected, the system logs every event on the system until it is rebooted or the option is turned off. This is useful if you believe your machine is not functioning correctly. You can record what your machine is doing and export the log and share it with Fluidigm technical support for troubleshooting. By default, this option is not selected. Clean System. Allows you to manually clean the system. For more information, see Manually Clean the System on page 36. Export Log. Allows you to export system activity logs if you selected Enable Full Logging for this Session on the Settings screen. For more information, see Export Logs on page

19 Chapter 3: Using the IFC Controller Software Administrator Tools Administrator Tools When logged in as Administrator you can manage users, passwords, settings, and scripts. 1 Press Tools at the bottom right of the screen. The Tools menu appears: Edit User On the Edit User screen, you can edit user name, password, and notification by clicking the corresponding Edit buttons. 19

20 Chapter 3: Using the IFC Controller Software Administrator Tools If you edit notification, a new screen appears. You can receive notifications by or by text message. If you select By Phone Number and Carrier, you also have to select the carrier service that you subscribe to. Change Settings 1 Press Settings. Settings on this screen include: Enable Full Logging for this Session. If this option is selected, the system logs every event on the system until it is rebooted or the option is turned off. This is useful if you believe your machine is not functioning correctly. You can record what your machine is doing and export the log to share with Fluidigm technical support for troubleshooting. By default, this option is turned off. Enable Barcode. Selected by default. The barcode reader attempts to read the barcode of every IFC. If you are running an IFC that does not have a barcode, you can turn off this setting. We recommend that you keep the barcode reader enabled. The instrument will display only those scripts that pertain to your IFC type. This helps prevent errors in script selection. 20

21 Chapter 3: Using the IFC Controller Software Administrator Tools 2 Press Save if you change the settings. WX Operating in Group Mode You can operate the IFC controller WX in conjunction with other IFC controllers. 1 Select This instrument is the group master on the instrument you wish to use as the master controller. 2 On the instruments you wish to link to the master controller, open Group Mode Settings and select This instrument is the group worker. 3 Return to the master IFC controller and select Add More Workers. 21

22 Chapter 3: Using the IFC Controller Software Administrator Tools 4 Select the controllers to link. WX wx-1 5 Click Add Workers. The master controller now has a Master Mode icon on its screen and the worker controller(s) now have a Worker Mode icon on their screen. Master mode Worker mode You can now control the worker IFC controllers remotely via the master IFC controller. 22

23 Chapter 3: Using the IFC Controller Software Administrator Tools 6 Select the number of IFCs you wish to run. The default number is the number of IFC controllers connected via group operating mode. For example, if you have four IFC controllers linked, four will be the default number of IFCs to run. If you only want to run two, select 2 to adjust the number. Master mode WX-1 To leave the worker or master modes, click Exit Mode. 7 You can also operate a system independently by selecting This instrument is independent. The screen indicates it is in worker mode, independent of any other systems: WX-1 23

24 Chapter 3: Using the IFC Controller Software Administrator Tools Clean System (manually) 1 Press Clean System. 2 Place the cleaning plate on the tray and press Start System Cleaning. 3 When the system purge is complete, the tray ejects. For more details, see Manually Clean the System on page 36. Network Settings WX-1 Database address On the Network Setting tab, your IT professional can network the IFC controller to your company s network and obtain an IP address dynamically through DHCP or use a static IP address. Other editable items are: DNS addresses Network unit name If you are networking multiple IFC controllers, you need to edit the network unit name. Controllers are delivered with the same default name. Database address 24

25 Chapter 3: Using the IFC Controller Software Administrator Tools On the Server tab, editable items include: Mail server Port number User name Password From Manage Users Use the Manage Users screen to add, delete, and edit users. 1 Press Manage Users. 2 Press Add New User. 3 Use the onscreen keyboard to enter a user name. 4 Press Next. 25

26 Chapter 3: Using the IFC Controller Software Administrator Tools 5 To assign a password for this user, press Change. Enter a password using the onscreen keyboard. 6 Assign an access level by choosing Normal or Administrator. Normal access level allows basic script running. Administrator access level allows basic script-running and the ability to change user access and passwords and manage scripts and system settings. 7 Press Save. The new user name appears on the login screen. 26

27 Chapter 3: Using the IFC Controller Software Administrator Tools Export Logs If you enabled Full Logging for this Session in the Settings screen, you can export system logs to a USB drive. 1 Press Export Logs from the Tools menu. 2 Insert your USB drive into the USB port on the back of the instrument. 3 Press Export. Change Time/Date 1 Press Change Time/Date. Use the blue arrows to adjust the time and date from this screen. 2 Press Save when finished. 27

28 Chapter 3: Using the IFC Controller Software Log Out Manage Scripts For more detailed information on loading and updating scripts, see Update Software and Scripts on page Press Manage Scripts. 2 Add scripts from a USB drive or copy scripts to a USB drive from this screen. Your scripts must be in a folder named Scripts on your USB drive for the IFC controller to find them. 3 Press Save. Scripts in the IFC Controller WX Software The available IFC controller scripts are: Script Load Mix (168x) Description Pressurizes the primer and sample into the reaction chambers and closes the containment valves at the end. Log Out 1 When you are finished using the IFC controller, press Logout at the bottom right of the screen. 2 Press Log Off. 28

29 Chapter 3: Using the IFC Controller Software Update Software and Scripts Update Software and Scripts Occasionally, Fluidigm provides updates to the system software and new scripts. Check for updates on our website at fluidigm.com/software Install Updated Software and Scripts 1 Turn off IFC controller WX by pressing the power switch at the back of the instrument. 2 Insert the USB drive containing the updates into the USB port. 3 Turn on IFC controller WX by pressing the power switch at the back of the instrument. 4 Press Update All to update the software and firmware. You can also update only the firmware or only the software. IFC Update Utility UPDATE ALL UPDATE FIRMWARE UPDATE SOFTWARE A status screen indicates the software/firmware was successfully updated. The instrument was successfully updated Please remove the USB Key and reboot the instrument to complete the update. 5 Turn off the IFC controller, take out the USB drive, and turn the controller back on to reboot the system. 29

30 Chapter 3: Using the IFC Controller Software Update Software and Scripts Load New Scripts 1 Log in as Administrator. 2 Press Tools. 3 Press Manage Scripts. 4 To add all of the new scripts, press Add All Scripts from USB Key. Load Mix (168x) You can now view, rename, or delete the individual scripts. To select a script, press the script s name. This example shows Load Mix (168x). Load Mix (168x) 30

31 Chapter 3: Using the IFC Controller Software Update Software and Scripts You can now change its name or delete it. Load Mix (168x) Load Mix 5 To change the name of the selected script, press Change and enter a new name. 6 To delete unwanted scripts, press Delete Script. 31

32 Appendix A: Troubleshooting and Maintenance Observation and Possible Course of Action Observation Possible Cause Recommended Action IFC controller WX failed to power on. There is no display after power is turned on. Compression force is out of range. Error messages Pump timed-out error IFC load error/cannot read barcode No AC power IFC controller WX fuse is faulty IFC controller WX power supply is not fully reset The compression cylinder pressure is out of range One or more of the O-rings may be unseated Blue protective film may not have been removed from bottom of IFC Check that the power cable is properly connected to both wall socket and IFC controller WX. Make sure the power switch on wall socket is on, and then turn on the instrument power switch on the back panel. If using a power strip, make sure it is turned on. Refer to Fuse Replacement on page 38 and replace both fuses with the supplied replacement fuses. Turn off the IFC controller WX power switch located on the back panel. Wait for 10 seconds and re-boot it by turning on the power switch. Call technical support. Reboot the system. If the system fails to recover, call technical support. Check interface plate O-rings. (See Clean the Interface Plate on page 33.) Ensure blue protective film is removed from the bottom of the chip before loading into the IFC controller WX. 32

33 Appendix A: Troubleshooting and Maintenance Clean the IFC Controller Clean the IFC Controller IFC controller WX requires very little maintenance other than regular cleaning of the IFC loading bay and the removable interface plate. With reusable IFCs, perform the system clean and also clean the interface plate before every IFC run on both the Load and Wash IFC controllers. You can run the cleaning protocol manually by accessing the Clean System script in the Tools menu. Clean the Interface Plate 1 After the tray ejects, remove the interface plate. Removable interface plate 2 Using a lint-free cloth and DNAZap (Life Technologies, PN AM9890), gently wipe the top and bottom of the interface plate. 33

34 Appendix A: Troubleshooting and Maintenance Clean the IFC Controller 3 Use clear tape to remove any dust particles. 4 Reinstall the cleaned removable interface plate: a b Orient the plate so that THIS SIDE UP is facing up. Slide the plate into the guide until it stops and you hear a click. IMPORTANT There are eight black O-rings inserted on one side of the removable interface plate. Be sure they are not misplaced or removed while handling the plate. During interface plate installation, these O-rings should face up. Contact technical support if you need replacement O-rings. 5 Press Done when finished. 34

35 Appendix A: Troubleshooting and Maintenance Clean the IFC Controller Clean the System Follow the onscreen instructions: 1 Press Clean. The System Cleaning Instructions screen appears. 2 Place cleaning plate onto tray. 35

36 Appendix A: Troubleshooting and Maintenance Clean the IFC Controller 3 Press Start System Cleaning. A status screen appears: 4 When the system purge is complete, eject the tray. 5 Wipe the tray out with water and let it dry for its next use. Manually Clean the System You can manually clean the system at any time. 1 Eject the IFC. 2 Press Tools. 3 Press Clean System. The System Cleaning Instructions screen appears. 36

37 Appendix A: Troubleshooting and Maintenance Clean the IFC Controller 4 Place the cleaning plate on the tray and press Start System Cleaning. A status screen appears. 5 When the system purge is complete, the tray ejects. 37

38 Appendix A: Troubleshooting and Maintenance Fuse Replacement Fuse Replacement No fuse replacement is required during installation. If the power fuse is faulty, replace it as follows. The fuse is rated 250V / 3.15A. 1 Turn off and unplug power cord from wall outlet. 2 Remove fuse casing from the IEC inlet power switch. 3 Push and release fuse holder blocks as shown below. 38

39 Appendix A: Troubleshooting and Maintenance Fuse Replacement 4 Replace faulty fuses and reinstall the IEC filter. Follow the arrow marks in the fuse holder to match IEC casing. Arrow marks 39

40 Appendix B: IFC Controller Site Requirements and Setup CAUTION The IFC controller is shipped in one cardboard box containing the controller, power cables, and spare fuses. It weighs 59 lb (27 kg). Use caution when moving the shipping box. CAUTION The IFC controller must be installed and operated in accordance with Fluidigm recommendations. Failure to follow these instructions may invalidate your warranty and/or diminish the safe functioning of your instrument. Site Requirements To operate the IFC controller, your site should meet the following requirements: One electrical power outlet A workspace that accommodates the IFC controller Proper Grounding/Protective Earth Connection To reduce the risk of electrical shock, connect the IFC controller to the AC power main through a grounded power cable at the power outlet. Electrical Requirements The IFC controller should be plugged into a standard US-type power strip with surge protector that provides single-phase AC voltage, between 100 and 240 V (60 or 50 Hz). 40

41 Appendix B: IFC Controller Site Requirements and Setup Site Requirements Uninterruptible Power Supply If your local power supply is subject to frequent power interruptions, you can protect your experiment setups on the IFC controller by using an uninterruptible power supply (UPS) with these minimum requirements: Output Power Capacity Backup Time (Run-Time) Output Voltage 500W (800VA) ±30 minutes at 500W VAC Output Connection NEMA 5-15R The UPS described above is sufficient to maintain power to one IFC controller. Workspace Provide a work surface that can accommodates the IFC controller. The following table shows the instrument dimensions and weight. Length Width Height Weight 19 in (48.3 cm) 9.5 in (24.1 cm) 13 in (33 cm) 59.4 lb (27 kg) The IFC controller is designed as desktop equipment. It can be placed on a laboratory bench top. To accommodate one IFC controller, we recommend you supply a bench top with minimum depth of 25 in (63.5 cm) and width of 16 in (40.6 cm). To allow adequate air circulation, keep at least 2 in (5.08 cm) clearance behind the IFC controller. Multiple controllers can be stacked together side by side. IMPORTANT Do not place the IFC controller on a heated surface or directly above a source of heat. Do not place the IFC controller in a position that makes it difficult to operate or disconnect from power. 41

42 Appendix B: IFC Controller Site Requirements and Setup Electrical Connection 13 in (33 cm) 9.5 in (24.1 cm) 2 in (5.1 cm) clearance 6 in (15.2 cm) Figure 3. IFC controller dimensions 19 in (48.3 cm) 25 in (63.5 cm) Electrical Connection The IFC controller is a standalone desktop instrument that requires only one electrical connection (Figure 4) at the back of the IFC controller. The top left corner has an AC power input socket and a power on/off switch. On/off switch Power cord Figure 4. Electrical connection 42

43 Appendix B: IFC Controller Site Requirements and Setup Unpack the IFC Controller Unpack the IFC Controller CAUTION LIFTING HAZARD. The IFC controller is shipped in one cardboard box that also contains a power cable and cleaning plates; together they weigh 59 lb (27 kg). Use proper lifting techniques. We recommend using at least two people to lift the IFC controller from the box. 1 Unpack the box near its permanent place in the lab. 2 Remove components from plastic wrapping. 3 Confirm that IFC controller, power cable, and cleaning plates are included in the box. If anything is missing, contact technical support. For phone or contact information, see page 2. Install the IFC Controller IMPORTANT Do not place the IFC controller on a heated surface or directly above a heat source. 1 Place the IFC controller on a laboratory bench top. For more details, see Workspace on page Provide at least 2 in (5.1 cm) of clearance behind the controller to allow adequate air circulation. See Figure 3 on page

44 Appendix B: IFC Controller Site Requirements and Setup Connect the Power Cable Connect the Power Cable 1 Connect the power cable to the IFC controller. On/off switch Power cord 2 Plug in the IFC controller to an electrical outlet that provides single-phase AC voltage, between 100 and 240 volts (50 or 60 Hz). Make sure all power switches are off. No additional grounding is required. IMPORTANT Current requirement is 5 amps, but the outlets must be of US standard (NEMA 1-15P) blade type. If you are not operating in the United States, Fluidigm provides a country-specific power cord. If your local power supply is subject to frequent power interruptions, you may protect your IFC runs on the IFC controller by using an uninterruptible power supply (UPS). For more information, see Uninterruptible Power Supply on page 41. Power On the IFC Controller 1 If you are using a surge protector power strip, turn it on. 2 Turn on the power switch at the back of the instrument. On/off switch 3 Wait while the IFC controller initializes. Initialization may take up to 5 minutes to complete. The IFC controller uses a touchscreen interface. Once you power on the instrument, all interactions with the application occur by touching the screen. 44

45 Appendix C: Safety General Safety In addition to your site-specific safety requirements, Fluidigm recommends the following general safety guidelines in all laboratory and manufacturing areas: Use personal protective equipment (PPE): safety glasses, fully enclosed shoes, lab coats, and gloves. Know the locations of all safety equipment (fire extinguishers, spill kits, eyewashes/ showers, first-aid kits, safety data sheets, etc.), emergency exit locations, and emergency/injury reporting procedures. Do not eat, drink, or smoke in lab areas. Maintain clean work areas. Wash hands before leaving the lab. Instrument Safety WARNING Do not modify this device. Unauthorized modifications may create a safety hazard. WARNING BIOHAZARD. If you are putting biohazardous material on the instrument, use appropriate personal protective equipment and adhere to Biosafety in Microbiological and Biomedical Laboratories (BMBL) from the Centers for Disease Control and Prevention and to your lab s safety protocol to limit biohazard risks. If biohazardous materials are used, properly label the equipment as a biohazard. For more information, see the BMBL guidelines at: cdc.gov/biosafety/publications/index.htm 45

46 Appendix C: Safety Instrument Safety Instrument Symbols Symbol English Français Caution, risk of danger Consult the manual for further safety information. Caution, hot surface Attention, risque de danger Consulter le manuel pour d autres renseignements de sécurité. Attention, surface chaude Pinch hazard Risque de pincement Biohazard Risque biologique On/off On/off (marche/arrêt) Protective conductor terminal (main ground). It must be connected to earth ground before any other electrical connections are made to the instrument. To minimize negative environmental impact from disposal of electronic waste, do not dispose of electronic waste in unsorted municipal waste. Follow local municipal waste ordinances for proper disposal provisions and contact customer service for information about responsible disposal options. Borne de conducteur de protection (mise à la terre principale) Pour minimiser les conséquences négatives sur l environnement à la suite de l élimination de déchets électroniques, ne pas éliminer ce déchet électronique avec les déchets usuels non soumis au tri sélectif. Se conformer aux ordonnances locales sur les déchets municipaux pour les dispositions d élimination et communiquer avec le service à la clientèle pour des renseignements sur les options d élimination responsable. Conformity mark Description Indicates conformity with safety requirements for Canada and the United States. Indicates conformity with European Union requirements for safety and electromagnetic compatibility. 46

47 Appendix C: Safety Chemical Safety Chemical Safety Read and comprehend all safety data sheets (SDSs) by chemical manufacturers before you use, store, or handle any chemicals or hazardous materials. Wear personal protective equipment (gloves, safety glasses, fully enclosed shoes, lab coats) when handling chemicals. Do not inhale fumes from chemicals. Use adequate ventilation, and return caps to bottles immediately after use. Check regularly for chemical spills or leaks. Follow SDS recommendations for cleaning up spills or leaks. Disposal of Products Used IFCs should be handled and disposed of in accordance with federal, state, regional, and local laws for hazardous waste management and disposal. Do not dispose of this product in unsorted municipal waste. This equipment may contain hazardous substances that could affect health and the environment. Use appropriate take-back systems when disposing of materials and equipment. Learn more at fluidigm.com/compliance 47

48 Appendix C: Safety Disposal of Products 48

49 For technical support visit fluidigm.com/support

IFC Controller MX and IFC Controller HX USER GUIDE

IFC Controller MX and IFC Controller HX USER GUIDE PN 68000112 G1 IFC Controller MX and IFC Controller HX USER GUIDE For Research Use Only. Not for use in diagnostic procedures. Information in this publication is subject to change without notice. It is

More information

PN D1 USER GUIDE IFC Controller AX

PN D1 USER GUIDE IFC Controller AX PN 68000157 D1 USER GUIDE IFC Controller AX For Research Use Only. Not for use in diagnostic procedures. Information in this publication is subject to change without notice. It is Fluidigm policy to improve

More information

Data Collection Software Release Notes. Real-Time PCR Analysis Software Release Notes. SNP Genotyping Analysis Software Release Notes

Data Collection Software Release Notes. Real-Time PCR Analysis Software Release Notes. SNP Genotyping Analysis Software Release Notes PN 101-6531 D1 RELEASE NOTES Biomark/EP1 Software To download the latest version of the software for Biomark HD, Biomark, and EP1, go to fluidigm.com/software. For more information about updating the software,

More information

Controller Specifications

Controller Specifications INRODUCTION Chromium Controller Specifications FOR USE WITH Chromium Controller & Accessory Kit PN-120223 NOTICES Notices Manual Part Number CG00020 Rev B Legal Notices 2017 10x Genomics, Inc. All rights

More information

Avanti HP Series Centrifuges Preinstallation

Avanti HP Series Centrifuges Preinstallation J3HP-TB-001AC May 2009 Avanti HP Series Centrifuges Preinstallation INTRODUCTION Purchase of an Avanti HP series high performance centrifuge includes installation and Basic Instrument Training for two

More information

HP Deskjet F2100 All-in-One series. Basics Guide

HP Deskjet F2100 All-in-One series. Basics Guide HP Deskjet F2100 All-in-One series Basics Guide Hewlett-Packard Company notices The information contained in this document is subject to change without notice. All rights reserved. Reproduction, adaptation,

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

PR3400 Series 1.4Mp USB Cameras Hardware Guide

PR3400 Series 1.4Mp USB Cameras Hardware Guide PR3400 Series 1.4Mp USB Cameras Hardware Guide Manufactured by: SPOT Imaging Solutions, a division of Diagnostic Instruments, Inc. 6540 Burroughs Ave. Sterling Heights, MI 48314-2133 USA Toll-Free: 866-604-SPOT

More information

EC Series. Safety Guide

EC Series. Safety Guide EC Series Safety Guide R5906018/02 01/07/2017 Barco Inc, Image Processing 3078 Prospect Park Drive, Rancho Cordova, CA, 95670, USA Phone: +1 916 859-2500 Fax: +1 916 859-2515 Support: www.barco.com/en/support

More information

User Safety. Electrical Safety. Phaser 4500 Laser Printer

User Safety. Electrical Safety. Phaser 4500 Laser Printer User Safety Your printer and the recommended supplies have been designed and tested to meet strict safety requirements. Attention to the following information will ensure the continued safe operation of

More information

MODEL 805 USER MANUAL

MODEL 805 USER MANUAL MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any

More information

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown TOT Series Manual North American and International Models - without optional faceplate Receptacle Panel of International Models, CE model shown North American Models Table of Content 1. Important Safety

More information

DC-D4213RX DC-D4213WRX

DC-D4213RX DC-D4213WRX Network Camera Quick Guide DC-D4213RX DC-D4213WRX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Agilent 70612B K18 Switch Matrix

Agilent 70612B K18 Switch Matrix Agilent 70612B K18 Switch Matrix Hardware Reference Manual Agilent Technologies COPYRIGHT 2000 AGILENT TECHNOLOGIES, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR

More information

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models TOT Series Manual North American CE and UK Models CE Models UK Models North American Models Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement

More information

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide Overview The SEL-3421 Motor Relay HMI can: Read metering and monitoring data. Inspect targets. Control relay operations. Display diagnostics. Display,

More information

Network Camera. Quick Guide DC-B1203X. Powered by

Network Camera. Quick Guide DC-B1203X. Powered by Network Camera Quick Guide DC-B1203X Powered by Safety Precautions English WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

User Guide True RMS Multimeter Extech EX205T

User Guide True RMS Multimeter Extech EX205T User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A Stacking Module AT-MCF2000S Installation Guide PN 613-000708 Rev A Copyright 2007 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission

More information

Variable-Speed Vortex Mixer

Variable-Speed Vortex Mixer Variable-Speed Vortex Mixer User Guide Version 1.1 IEC connector Retort rod fitting Rubber cup Speed control dial Power on/off button Mode button Figure 1: Vortex Mixer Figure 2: Front panel 2 Variable-Speed

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

Quick Start Guide and Health and Safety Information

Quick Start Guide and Health and Safety Information D397-10-880 Issue F Original Quick Start Guide and Health and Safety Information Turbo Instrument Controller (TIC) Description TIC Instrument Controller 3 Gauge TIC Instrument Controller 6 Gauge TIC Instrument

More information

Please read this safety information carefully and keep this user manual for later reference.

Please read this safety information carefully and keep this user manual for later reference. Please read this safety information carefully and keep this user manual for later reference. This LED bulb is for indoor use only. Please disconnect this bulb from bulb holder before cleaning. Don t use

More information

Version 1.0 March 2014 OLC 10.1

Version 1.0 March 2014 OLC 10.1 User Manual Version 1.0 March 2014 OLC 10.1 Copyright 2014 All Rights Reserved Manual Version 1.0 The information contained in this document is subject to change without notice. We make no warranty of

More information

Customer Responsibilities

Customer Responsibilities For Research Use Only. Not for use in diagnostic procedures. Thank you for purchasing the Agilent G5590A BenchCel Workstation. To get you started and to assure a successful and timely installation, please

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

Label Printer QL-810W/820NWB. Quick Setup Guide (English)

Label Printer QL-810W/820NWB. Quick Setup Guide (English) Label Printer QL-810W/820NWB Quick Setup Guide (English) Label Printer QL-810W/820NWB Printed in China D00RPG001 Quick Setup Guide (English) Available Manuals Product Safety Guide This guide provides safety

More information

Always there to help you Register your product and get support at SBT300/12. Question? Contact Philips.

Always there to help you Register your product and get support at   SBT300/12. Question? Contact Philips. Always there to help you Register your product and get support at www.philips.com/welcome Question? Contact Philips SBT300/12 User manual Contents 1 Important 3 Safety 3 Notice 3 2 Your Bluetooth Speaker

More information

ThunderBolts System/RainDance Source Operator s Manual

ThunderBolts System/RainDance Source Operator s Manual ThunderBolts System/RainDance Source Operator s Manual Patent, Trademarks, & Copyrights Patent www.raindancetechnologies.com/patents Trademarks RainDance Technologies, the RainDance Technologies logo,

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

±15 V Current-Limited Power Supply

±15 V Current-Limited Power Supply USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus EU Declaration of Conformity We declare that the accompanying

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer

INSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer INSTRUCTION MANUAL Instruction Manual Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance

More information

80W (16V/5A) Power Supply with USB Output. User Manual

80W (16V/5A) Power Supply with USB Output. User Manual Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1325 80W (16V/5A) Power Supply with USB Output User Manual 1325 Volt. C.V. Amp. C.C. V OUTPUT ON/OFF A

More information

ASPECT Reader User Guide - English Software Version 1.4.0

ASPECT Reader User Guide - English Software Version 1.4.0 ASPECT Reader User Guide - English Software Version 1.4.0 UG0001 - EN AW201127 Rev. 4 August 2016 Before You Begin Several important sources of information are available to help get you started and to

More information

QSW16M 16 Chn PoE managed switch

QSW16M 16 Chn PoE managed switch QSW16M 16 Chn PoE managed switch 1 Before You Begin Read these instructions before installing or operating this product. Note: This installation should be made by a qualified service person and should

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31

More information

Quick Start Guide Axxin T8-ISO. Instrument. In association with: E: W: D Version 1.5

Quick Start Guide Axxin T8-ISO. Instrument. In association with: E: W:   D Version 1.5 Quick Start Guide Axxin T8-ISO Instrument In association with: E: support@axxin.com W: D006093 Version 1.5 Office DOCUMENT CONTROL DETAILS TITLE DOC No. CUSTOMER CONTACT QSG, Quick Start Guide, Axxin T8-ISO

More information

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL UNITED STATES Contents Safety Information... 2 Save These Important Safety Instructions... 2 Warnings...2 Cautions...3 General Information... 4 Mobile Connector

More information

Demonstrated Protocol: How to Set Up the Ion OneTouch 2 Instrument When Switching Between the Ion PGM System and Ion Proton System

Demonstrated Protocol: How to Set Up the Ion OneTouch 2 Instrument When Switching Between the Ion PGM System and Ion Proton System USER BULLETIN Demonstrated Protocol: How to Set Up the Ion OneTouch 2 Instrument When Switching Between the Ion PGM System and Ion Proton System Publication Number MAN0007719 Revision 2.0 Overview.............................................................

More information

Network Camera. User Manual V3.2.0

Network Camera. User Manual V3.2.0 Network Camera User Manual V3.2.0 Network Camera User Manual 1 This manual applies to the following camera models: CAM-IPM-D3-VP CAM-IPM-2D3-VP CAM-IPM-03D-21VP CAM-IPM-2D-29P-VP CAM-IPM-3D-29P-VP CAM-IPM-13D-29VPC

More information

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL

ANI SWH. PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL ANI-15115-08SWH PDU: Per Outlet Control and Total Current Monitoring INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75034 TOLL FREE: 1-877-ANEUTRON TOLL: (469) 362-9228 Email: sales@a-neutronics.com

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

LVN5200A-R2, rev. 1, Hardware Installation Guide

LVN5200A-R2, rev. 1, Hardware Installation Guide LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive

More information

Getting Started. HP Notebook PC. Tagged for Accessibility

Getting Started. HP Notebook PC. Tagged for Accessibility Getting Started HP Notebook PC Tagged for Accessibility Looking for more user guides? They are on your computer. Click Start > Help and Support > User Guides HP is committed to reducing the environmental

More information

TL-PA4010 AV600 Powerline Adapter

TL-PA4010 AV600 Powerline Adapter TL-PA4010 REV2.0.0 1910011622 CONTENTS Chapter 1 Introduction... 1 1.1 System Requirement... 1 1.2 Important Safety Instructions... 1 1.3 Conventions... 2 1.4 LED Indicator... 2 1.5 Physical Interface...

More information

AOC MONITOR USER`S GUIDE V22+ SAFETY INTRODUCTION.2 SETUP.4 ADJUSTING...7 DRIVER INSTALLATION GUIDE.. 10 PRODUCT INFORMATION.16 TROUBLESHOOT...

AOC MONITOR USER`S GUIDE V22+ SAFETY INTRODUCTION.2 SETUP.4 ADJUSTING...7 DRIVER INSTALLATION GUIDE.. 10 PRODUCT INFORMATION.16 TROUBLESHOOT... AOC MONITOR USER`S GUIDE V22+ SAFETY INTRODUCTION.2 SETUP.4 ADJUSTING......7 DRIVER INSTALLATION GUIDE.. 10 PRODUCT INFORMATION.16 TROUBLESHOOT......17 Page١ SAFETY INTRODUCTION The following subsections

More information

Model: VA/230W UPS Backup System

Model: VA/230W UPS Backup System IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of unit.

More information

Network Camera. Quick Guide DC-T3243HRX. Powered by

Network Camera. Quick Guide DC-T3243HRX. Powered by Network Camera Quick Guide DC-T3243HRX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

minipcr Mobile App operation (Android devices) Appendix: maintenance and operating conditions

minipcr Mobile App operation (Android devices) Appendix: maintenance and operating conditions minipcr TM Thermal Cycler User s Guide Contents I. Loading your samples II. Setting up your minipcr TM thermal cycler III. Creating, storing, and editing protocols IV. Running and monitoring protocols

More information

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0

TP3005P EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0 EN PROGRAMMABLE DC LAB POWER SUPPLY 0-30V/ USB 2.0 16 15 17 2 1. Introduction USER MANUAL To all residents of the European Union Important environmental information about this product This symbol on the

More information

DC-D2212R / DC-D2212WR

DC-D2212R / DC-D2212WR Network Camera Quick Guide / DC-D2212WR Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

TABLET DOCK USER S GUIDE

TABLET DOCK USER S GUIDE Fujitsu Stylistic ST Series Tablet PC TABLET DOCK USER S GUIDE Warning Handling the cord on this product will expose you to lead, a chemical known to the State of California to cause birth defects or other

More information

Startup Guide C01

Startup Guide C01 Startup Guide 4012988-00 C01 Startup Guide English Where to Find Information........................ 2 Safety Instructions.............................. 4 Important Safety Instructions...........................

More information

Multi-touch Touch-Screen. Installation Guide

Multi-touch Touch-Screen. Installation Guide Multi-touch Touch-Screen Installation Guide Table of Contents Read before use...3 Safety and troubleshooting information...4 Installing Software...8 Connecting Cables... 13 Calibrating the Touch Screen...

More information

MyGenie TM 32 Thermal Block

MyGenie TM 32 Thermal Block User s Guide MyGenie TM 32 Thermal Block A-2030-4 MyGenie TM 32 Thermal Block User s Guide Version No.: 1.1 (2013-05) Please read all the information in booklet before using the instrument Bioneer 8-11,

More information

QIT600F1 USER'S GUIDE

QIT600F1 USER'S GUIDE QIT600F1 USER'S GUIDE 1 IMPORTANT SAFEGUARDS Warnings: 1. Read all of these instructions. Save these instructions for later use, please. 2. Unplug this monitor from the wall outlet before cleaning. Do

More information

InVue BT128 Refractometer

InVue BT128 Refractometer ADVANCED MATERIALS HANDLING USER GUIDE InVue BT128 Refractometer Process monitoring for laboratory fluid applications in a benchtop package TABLE OF CONTENTS Cautions and Warnings... 4 Safe Disposal...

More information

english Thanks for choosing the Xbox GB Hard Drive. The Xbox GB Hard Drive lets you save games, save music and create

english Thanks for choosing the Xbox GB Hard Drive. The Xbox GB Hard Drive lets you save games, save music and create english Thanks for choosing the Xbox 360 120GB Hard Drive. The Xbox 360 120GB Hard Drive lets you save games, save music and create english NOTE Because the Xbox 360 system software uses some of the memory

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation

More information

VeniceU16/VeniceU24/VeniceU32

VeniceU16/VeniceU24/VeniceU32 VeniceU16/VeniceU24/VeniceU32 Quick Start Guide midasconsoles.com 2 VeniceU16/VeniceU24/VeniceU32 Quick Start Guide VeniceU16/VeniceU24/VeniceU32 Quick Start Guide 3 Important Safety Instructions Terminals

More information

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm Network Camera Quick Guide DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input. LMC5103A-R2 1-slot Multipower Desktop Chassis (Module Not Included) This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Network Keyboard. Quick Start Guide UD01317N

Network Keyboard. Quick Start Guide UD01317N Network Keyboard Quick Start Guide UD01317N Quick Start Guide About this Guide This Guide is applicable to network keyboard. The Guide includes instructions for using and managing the product. Pictures,

More information

Allworx 24x Service and Troubleshooting Guide

Allworx 24x Service and Troubleshooting Guide Allworx 24x Service and Troubleshooting Guide -PAGE INTENTIALLY LEFT BLANK- Table of Contents 1 Safety Instructions...1 1.1 Electrical...1 1.2 Electrostatic Discharge...1 2 Chassis Views...2 3 Exterior

More information

EVO-TM2A EVO-TM2B Touch Screen Monitor

EVO-TM2A EVO-TM2B Touch Screen Monitor User Manual Revision v1.3 Dec. 2010 EVO-TM2A EVO-TM2B Touch Screen Monitor Copyright 2010 August All Rights Reserved Manual Version 1.3 Part Number: The information contained in this document is subject

More information

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A 8 Button RS232/IR Control Panel 500816 MuxLab Inc. 2016 94-000833-A / SE-000833-A SAFETY PRECAUTIONS To insure the best use from the product, please read all instructions carefully before using the device.

More information

PanelView 600 Terminals

PanelView 600 Terminals Installation Instructions PanelView 600 Terminals Catalog Numbers 2711-K6Cxx, 2711-B6Cxx Topic Page Hazardous Location Considerations 3 European Union Directive Compliance 4 Wiring and Safety Guidelines

More information

User Manual Infinity:One

User Manual Infinity:One User Manual Infinity:One For the latest updates and information, please visit: support.one-education.org Notice The information in this user s manual is protected by copyright laws, all parts of this manual,

More information

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Mercury Helios ASSEMBLY MANUAL & USER GUIDE Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp

More information

9040/9040UK. Users Manual. Phase Rotation Indicator

9040/9040UK. Users Manual. Phase Rotation Indicator 9040/9040UK Phase Rotation Indicator Users Manual PN 2438546 April 2005 2005 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

ArmorPoint I/O Field Potential Distributor, Series A

ArmorPoint I/O Field Potential Distributor, Series A Installation Instructions ArmorPoint I/O Field Potential Distributor, Series A (Cat. No. 1738-FPD) The field potential distributor (Cat. no. 1738-FPD) lets you change the field power distribution source

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

Network Camera. Quick Guide DC-S1283WRX. Powered by

Network Camera. Quick Guide DC-S1283WRX. Powered by Network Camera Quick Guide DC-S1283WRX Powered by Safety Precautions Important Safeguards WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR

More information

TruVision IP Thermal Camera Installation Guide

TruVision IP Thermal Camera Installation Guide TruVision IP Thermal Camera Installation Guide P/N 1073335-EN REV B ISS 19OCT17 Copyright Trademarks and patents Manufacturer Certification 2017 United Technologies Corporation, Interlogix is part of UTC

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

PS8 - II. Professional Power Sequencer. User s Manual

PS8 - II. Professional Power Sequencer. User s Manual PS8 - II Professional Power Sequencer User s Manual IMPORTANT SAFETY INSTRUCTIONS READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure.

More information

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド Agilent 34401A 6½ 桁マルチメータ ユーザーガイド Safety Information General Do not use this product in any manner not specified by the manufacturer. The protective features of this product may be impaired if it is used

More information

Always there to help you. Register your product and get support at AEA2700. Question? Contact Philips.

Always there to help you. Register your product and get support at  AEA2700. Question? Contact Philips. Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AEA2700 User manual Contents 1 Safety 2 2 Your Bluetooth Adapter 3 Introduction 3 What's

More information

User's Guide. Digital Multimeter. Model MN42

User's Guide. Digital Multimeter. Model MN42 User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and

More information

SMART Board 8070i Interactive Display. Installation Guide

SMART Board 8070i Interactive Display. Installation Guide SMART Board 8070i Interactive Display Installation Guide Trademark Notice SMART Board, SMART Notebook, SMART Meeting Pro, smarttech and the SMART logo are trademarks of SMART Technologies ULC in the U.S.

More information

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE DECLARATION OF CONFORMITY according to FCC Part 15 Responsible Party Name: Fujitsu PC Corporation Address: 5200 Patrick Henry Drive Santa Clara,

More information

* * Agilent Power Distribution Unit (PDU) Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The

More information

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

3M RFID Tracking Pad Model 770

3M RFID Tracking Pad Model 770 3M RFID Tracking Pad Model 770 Owners Manual 3M Information and Materials Security 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 xx-xxxx-xxxx-x Rev 1 Copyright 2003 3M IPC. All rights reserved.

More information