OVERVIEW CALL STATIONS

Size: px
Start display at page:

Download "OVERVIEW CALL STATIONS"

Transcription

1

2 OVERVIEW CALL STATIONS Indoor Call Stations...3 Multifunctional Desktop Call Station, Analogue (MTSA)...3 MTSA Expansion Unit...4 MTSA Accessories...4 Multifunctional Desktop Call Stations, Digital (MTSD)...5 MTSD Expansion Unit...6 MTSD Wall-Mount Connector Box...6 MTSD Accessories...7 Required MTSD Power Supply Module for Different Configurations...7 MDK System Telephone, Digital...8 Configuration Example for an MDK Operator Unit...8 MDK PC Call Station...9 Weatherproof Call Stations...12 Weatherproof Analogue Call Station (WFA)...12 WFA Accessories...13 Weatherproof Analogue Compact Call Station (WFAK)...14 Weatherproof Digital Call Station (WFD)...15 WFD Accessories...16 Explosion-Proof Call Stations...17 Weatherproof Digital Call Station, Ex-Proof (WFD-EX)...17 Weatherproof Analogue Call Station, Ex-Proof (WFA-EX)...18 WFD-EX/WFA-EX Accessories W Auxiliary Amplifier for WFD/WFD-EX/WFA-EX Call Stations...19 Weatherproof Telephones...20 Weatherproof Telephone with Keypad (WTAT) or without Keypad (WTA)...20 Explosion-Proof Telephones...22 Explosion-Proof Telephone with Keypad (WTAT) or without Keypad (WTA)...22 Technical Details...24 IP Rating of Enclosures...24 General Information on the Designation of Explosion-Proof Equipment ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 2

3 Indoor Call Stations Multifunctional Desktop Call Station, Analogue (MTSA) The analogue version of the Multifunctional Desktop Call Station can be used with all analogue intercom systems. The desktop call stations feature from 8 to 32 illuminated pushbuttons, but can be expanded to up to 80 buttons with attachable expansion units. MTSA, 8 buttons Art. No MTSA, 48 buttons Art. No Equipment Features impact- and break-resistant ABS plastic enclosure flexible gooseneck electret microphone (300 mm) integrated full range speaker, 8 Ω replaceable illuminated pushbuttons with LED signaling incl. wall-mount connector box and 3-m connection cable (2 x 3-m cable with MTSA buttons) Functional Features intercom amplifier with integrated radio monitoring function switch to off or low volume (volume lowering by 12 db) pushbuttons select line for direct call connections functions can be configured from the control centre Art. No Physical Data Number of illuminated pushbuttons Weight (w/o wall-mount connector box) approx.1.1 kg approx. 1.9 kg Enclosure dimensions (H x W x D) 88 x 183 x 260 mm 88 x 368 x 260 mm Enclosure colour: top / base oyster white (RAL 1013) / graphite black (RAL 9011) Electrical Data Supply voltage 24 V DC or 48/60 V DC Max. quiescent current 30 ma (24 V DC) / 38 ma (48/60 V DC) Max. operating current 82 ma (24 V DC) / 135 ma (48/60 V DC) Amplifier power rating 1 W Min. input voltage for rated power 120 mv Average speech power (1 W / 1 m) 86 db Frequency range 150 Hz to 10 khz Environmental Conditions Climate class per DIN EN K4 (extended temperature range 0 to +50 C) Protection class IP30 per DIN EN / IEC 529 MTSA Wall-Mount Connector Box 2006 ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 3

4 MTSA Expansion Unit MTSA Call Stations can be expanded to up to 80 buttons by attaching expansion units. The basic enclosure of the expansion unit has 6 rows for button strips containing 8 buttons per row. The smallest configuration with 16 talk buttons has blank panels on the other 4 rows. MTSA Expansion Unit, 16 buttons Art. No Equipment Features impact- and break-resistant ABS plastic enclosure incl. second connector terminal board and 3-m connection cable incl. accessories to attach expansion unit to the base unit Art. No Physical Data Number of illuminated pushbuttons Weight (without connector board) approx. 0.8 kg approx. 1.1 kg Enclosure dimensions (H x W x D) 88 x 183 x 235 mm Enclosure colour: top / base oyster white (RAL 1013) / graphite black (RAL 9011) Environmental Conditions Climate class per DIN EN K4 (extended temperature range 0 to +50 C) Protection class IP30 per DIN EN / IEC 529 MTSA Accessories Article Description Art. No. Accessory Parts for MTSA Wall-Mount Connector Box MTSA Wall-Mount Connector Box 1) for MTSA Call Station with up to 32 buttons, ABS plastic enclosure, colour: pebble grey (RAL 7032), approx. 1.2 kg Expansion kit for Wall-Mount expansion connector board for 48 additional lines Connector Box (expansion kit for up to 80 buttons max.) MTSA connection cable 1) 50-pin SUB-D, colour: pebble grey (RAL 7032), 3 m MTSA connection cable 50-pin SUB-D, colour: pebble grey (RAL 7032), 5 m MTSA connection cable 50-pin SUB-D, colour: pebble grey (RAL 7032), 10 m Accessory Parts for MTSA Call Station Button strip button insert with 8 buttons Blank panel for button row instead of an MTSA button insert Button cover includes 5 screws Mounting kit for button cover incl. drill hole template, drill and assembly instructions Pushbutton cap ABS plastic, colour: sky blue (RAL 5015) Pushbutton cap ABS plastic, colour: rape yellow 2) (RAL 1021) Pushbutton cap ABS plastic, colour: fire red (RAL 3000) Pushbutton cap ABS plastic, colour: yellow green (RAL 6018) Pushbutton cap ABS plastic, colour: turquoise blue (RAL 5018) Pushbutton cap ABS plastic, colour: signal black (RAL 9004) Clear plastic hood for pushbutton cap PC plastic, colour: transparent ) Already included with the basic MTSA Call Stations. 2) Formerly named cadmium yellow (RAL 1021) ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 4

5 Multifunctional Desktop Call Stations, Digital (MTSD) The digital version of the Multifunctional Desktop Call Station is used in intercom systems together with the Multifunctional Digital Communication Centre (MDK). The desktop call stations have 8 or 16 illuminated pushbuttons, and they can be expanded to operator stations with up to 208 buttons by attaching one or more expansion units. MTSD, 8 buttons Art. No MTSD, 32 buttons Art. No Equipment Features 1) impact- and break-resistant ABS plastic enclosure flexible gooseneck electret microphone (300 mm) integrated full range speaker, 8 Ω replaceable illuminated pushbuttons with LED signaling back-lit, two-line LC display Functional Features intercom amplifier with integrated radio monitoring function switch to off or low volume (volume lowering by 12 db) pushbuttons select line for direct call connections functions can be configured from the MDK Centre pushbuttons definable as intercom line selection or for local functions two slots for text storage modules less wiring required Art. No Physical Data Number of illuminated pushbuttons Weight (w/o wall-mount connector box) approx. 1.1 kg approx. 1.9 kg Enclosure dimensions (H x W x D) 88 x 183 x 260 mm 88 x 368 x 260 mm Enclosure colour: top / base oyster white (RAL 1013) / graphite black (RAL 9011) Electrical Data Supply voltage range V DC Max. quiescent current 40 ma Max. operating current 180 ma Amplifier power rating 1 W Min. input voltage (radio a/b) 120 mv for rated power Average speech power (1 W / 1 m) 86 db Frequency range 300 Hz to 7 khz Intercom line interface S0 Communication protocol Neumann Protocol Environmental Conditions Climate class per DIN EN K4 (extended temperature range 0 to +50 C) Protection class IP30 per DIN EN / IEC 529 1) The Wall-Mount Connector Box and connection cable are not included with the MTSD Call Station (must be ordered separately) ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 5

6 MTSD Expansion Unit MTSD Call Stations can be expanded to operator stations with up to 208 buttons by attaching one or more expansion units. The basic enclosure of the expansion unit has 6 rows for button strips containing 8 buttons per row. The smallest configuration with 16 talk buttons has blank panels on the other 4 rows. MTSD Expansion Unit, 16 buttons Art. No Equipment Features impact- and break-resistant ABS plastic enclosure incl. second connector terminal board and 3-m connection cable incl. parts to attach expansion unit to the base unit Art. No Physical Data Number of illuminated pushbuttons Weight approx. 0.8 kg approx. 1.1 kg Enclosure dimensions (H x W x D) 88 x 183 x 235 mm Enclosure colour: top / base oyster white (RAL 1013) / graphite black (RAL 9011) Environmental Conditions Climate class per DIN EN K4 (extended temperature range 0 to +50 C) Protection class IP30 per DIN EN / IEC 529 MTSD Wall-Mount Connector Box The MTSD Wall-Mount Connector Box provides connections for the MTSD Call Station, an ISDN telephone, an analogue as well as a digital System Telephone, and it accepts a power supply module and two NT units U/S0. MTSD Wall-Mount Connector Box 1) Art. No Equipment Features painted, two-piece sheet steel enclosure connection sockets for an MTSD Call Station, ISDN telephone, and an analogue and digital system telephone accepts a power supply module and two NT units U/S0 Art. No Technical Data Weight (w/o NT units and w/o power approx. 1.4 kg supply module) Enclosure dimensions (H x W x D) 268 x 157 x 60 mm Enclosure colour pebble grey (RAL 7032) Interfaces MTSD call station 25-pin SUB-D socket Digital System telephone 8-pin modular jack (RJ 45) ISDN telephone 8-pin modular jack (RJ 45) Analogue telephone TAE6F jack MDK connection S0/U Environmental Conditions Climate class per DIN EN K4 (extended temperature range 0 to +50 C) Protection class IP30 per DIN EN / IEC 529 1) Not supplied with the MTSD Call Station (must be ordered separately) ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 6

7 MTSD Accessories Article Description Art. No. Accessory Parts for MTSD Wall-Mount Connector Box 1) ISDN power supply module 48 V DC / 40 V DC / ±5 V DC Power supply module 48/60 V DC / ±5 V DC (16 buttons max.) Power supply module 48/60 V DC / ±5 V DC (16 or more buttons) Power supply module 230 V AC / ± 5V DC (16 buttons max.) ISDN power supply module 230 V AC / 40 V DC / ±5 V DC Power cord 230 V AC, with shockproof plug, 3 x 0.75 mm 2, 2 m NT unit U/S0 ±5 V DC (up to 7 km max. distance to MDK Centre) MTSD connection cable 25-pin SUB-D, colour: pebble grey (RAL 7032), 3 m MTSD connection cable 25-pin SUB-D, colour: pebble grey (RAL 7032), 5 m MTSD connection cable 25-pin SUB-D, colour: pebble grey (RAL 7032), 10 m Accessory Parts for MTSD Call Station Button strip button insert with 8 buttons Blank panel for button row instead of an MTSD button insert Button cover includes 5 screws Mounting kit for button cover incl. drill hole template, drill and assembly instructions Pushbutton cap ABS plastic, colour: sky blue (RAL 5015) Pushbutton cap ABS plastic, colour: rape yellow 2) (RAL 1021) Pushbutton cap ABS plastic, colour: fire red (RAL 3000) Pushbutton cap ABS plastic, colour: yellow green (RAL 6018) Pushbutton cap ABS plastic, colour: turquoise blue (RAL 5018) Pushbutton cap ABS plastic, colour: signal black (RAL 9004) Clear plastic hood for pushbutton cap PC plastic, colour: transparent ) Not supplied with the MTSD Call Station (must be ordered separately). 2) Formerly named cadmium yellow (RAL 1021). Required MTSD Power Supply Module for Different Configurations Intended Required Power Supply Modules, Art. No. Supply Voltage 48/60 V DC 230 V AC MTSD Call Station ±5 V DC (16 buttons max.) (16 or more buttons) ISDN telephone 40 V DC (connected to the passive S0 bus) System telephone, digital (power supplied through ISDN line) 40 or 48 V DC ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 7

8 MDK System Telephone, Digital The digital MDK System Telephone, combined with the digital Multifunctional Desktop Call Station (MTSD), constitutes the central operator unit for universal MDK communications connections. This allows, for example, the telephone s function buttons to be mapped to intercom line selection buttons of the MTSD. Signal and voice communication uses a modified DSS1 protocol. The MDK System Telephone can also be used as an independent telephone with all of the standard features of digital technology. However, it is not possible to connect the telephone directly to the phone company s public network. Equipment Features impact- and break-resistant ABS plastic enclosure 12 function buttons, 4 for phone functions and 5 for other functions two-line alphanumeric LC display (2 x 20 characters) integrated speaker for loudspeaker talk/listen function connection jacks for talk/listen headset and recording device incl. 6-m connection cable MDK System Telephone Art. No Functional Features signal and voice communication using modified DSS1 protocol individual programming of function buttons, signaling and display text using the MDK PC/Diagnosis via V.24 (serial) interface Art. No Physical Data Weight approx. 1.2 kg Enclosure dimensions (H x W x D) 115 x 183 x 235 mm Enclosure colour: top / base oyster white (RAL 1013) / graphite black (RAL 9011) Interfaces Handset cord connector RJ 45 (4-pin modular jack) Headset (talk/listen) 8-pin DIN jack Recording device 6-pin DIN jack PC/Diagnosis V.24 (9-pin SUB-D socket) MDK connection S0 Communication protocol DSS1 protocol (modified) Environmental Conditions Climate class per DIN EN K4 (extended temperature range 0 to +50 C) Protection class IP30 per DIN EN / IEC 529 Configuration Example for an MDK Operator Unit MDK System Telephone + MTSD, 16 buttons Art. No / ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 8

9 MDK PC Call Station Monitor-Communication-Terminal for extended communication needs Features 40 keys on a single virtual operation screen Separation in 40 virtual operator screens Touch screen and mouse operation Flexible placement of microphone and loudspeaker Touch-desktop-monitor or Touch-built-in-monitor Direct connection to the MDK PC with Soundcard for communication Communication with enhanced voice quality Embedding of functional bitmaps into keys of the operation panel Integration of PA, intercom and telephone functions Free selection of telephone accessories Handset with cradle Headset System telephone with optional Headset The MDK PC call station consists of the hardware and software that can be found on page ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 9

10 MDK PC Call Station NEMMS- the ms Neumann Management System NEMMS is a computer-aided management system for which the configuration of the user-interface is variable. It works in a direct combination with the MDK-system. The operational areas of a customer can be graphically illustrated and accessed in separate sub-areas. The actions are executed by imbedded buttons in the respective graphic, and the handling is mouse-driven. Messages are also displayed according to the area of operation. For example there is a graphical transmission of the status of the sensors. So every demand of the customers concerning the ergonomics of the user-interface can be satisfied. One example for the innovative interface design shows the applications in Switzerland for emergency systems in tunnels. So far the following projects were realised: Gotthard, Seelisberg and the federal road N5 Features Monitor-Communication Terminal for location based operation Variable desktop screen Graphical and location based switch buttons Location based messages Separation into customized operator screens Direct connection to the MDK Operation with serial pointing device Intercom, PA and telephone (emergency call) applications PC with Soundcard for communication Communication with enhanced voice quality Embedding of functional bitmaps into keys of the operation panel Integration of PA, intercom and telephone functions Free selection of telephone accessories Handset with cradle Headset System telephone with optional Headset The MDK PC call station NEMMS consists of the hardware and software that can be found on page ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 10

11 Parts List for MDK PC Call Station and NEMMS, Hardware for Intercom and PA Applications: Art. No. Description Number of Items PC (currently available technology) with RS 422 card, sound 1 card and operating system Windows XP Touch screen desktop monitor 12.1" or Touch screen desktop monitor 15" COM extension cable VGA extension cable PC call station connection unit, intercom amplifier, incl. cables pin SUB-D connector kit (male and female) pin SUB-D male multipoint connector Connecting box AP, 9 pin SUB-D Shielded connecting cable, 2x2x0.6mm Electret gooseneck microphone Loudspeaker, in standard casing 96 x 96 mm 1 Parts List for MDK PC Call Station and NEMMS, Hardware for Telephony : System telephone Headset for system telephone 1 or Telephone headset Amplifier for telephone headset art. no Software for MDK PC Call Station PC call station software incl. dongle PC call station line configuration PC call station HD (Backup) 1 Software for MDK PC Call Station NEMMS PC call station NEMMS, incl. dongle PC call station line configuration (per line) Configuration per bitmap for one line PC call station HD backup ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 11

12 Weatherproof Call Stations Weatherproof Analogue Call Station (WFA) The Weatherproof Analogue WFA Call Stations provide direct intercom connections to other call stations and PA loudspeaker announcements both outdoors and indoors in harsh environments, such as in heavy industry facilities. When the robust two-way toggle keys are pressed, they activate contactless opto-couplers, which make them suitable for permanent use in aggressive, moist environments. The call stations are designed for wall mounting, and they cannot be expanded with expansion enclosures. Equipment Features dust- and watertight, fiberglassreinforced polyester enclosure two-way toggle keys with opto-coupler, 2 lines each integrated pressure chamber loudspeaker and electret microphone connector for optional Auxiliary Amplifier WFA Call Station, 1 two-way toggle Art. No WFA Call Station, 2 two-way toggles Art. No WFA Call Station, 3 two-way toggles Art. No Functional Features direct intercom connections, keycontrolled can be switched to low volume (nighttime operation) LED indication of incoming call and line busy, prioritized functions configurable via MDK less wiring required Art. No Physical Data Number of two-way toggle keys Weight (without auxiliary amplifier) approx. 6.5 kg Enclosure dimensions (H x W x D) 500 x 120 x 180 mm Enclosure colour pure orange (RAL 2004) Electrical Data Supply voltage range V DC Max. quiescent current [10mA Max. operating current [50mA [1A (with 25W additional amplifier) Amplifier power rating 280mW Min. input voltage for rated power 150mV Average speech power (1 W / 1 m) 86dB Frequency range 300 Hz to 10 khz (-3 to ±1 db) Environmental Conditions Climate class per DIN EN K6 (extended temperature range -25 to +70 C) Protection class per DIN EN / IEC 529 IP66 Device group, category per 94/9/EG-RL II 3G and 3D 2006 ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 12

13 WFA Accessories Article Description Art. No. Accessory Parts for WFA Call Station 25-W Auxiliary Amplifier 1) 25 W / 48/60 V DC Mounting kit adapter for drill holes of older call stations, incl. 2 angle brackets and 4 steel hexagon socket screws M6 x 18 Key insert two-way toggle keys for 2 Lines Blank panel instead of key insert Hexagon socket screw wrench SW5 for hexagon socket screws on enclosure panel ) Not included with WFD Call Stations Art. No , or ; for technical data, see pg ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 13

14 Weatherproof Analogue Compact Call Station (WFAK) The Weatherproof Analogue Compact Call Stations (WFAK) are intended for use in normal environments with low noise levels. These compact call stations, constructed for outdoor environmental conditions, provide an optimal cost-effective solution. The WFAK Call Station can be expanded to a compact, multiple-line call station by adding a 6-button WFAK Expansion Enclosure. WFAK Call Station, 3 line-keys Art. No (orange) Art. No (yellow) as above, but with connector for auxiliary amplifier Art. No (orange) Art. No (yellow) WFAK Expansion Enclosure, 6 line-keys Art. No (orange) Art. No (yellow) Equipment Features dust and splash-water protected, fiberglassreinforced polyester enclosure with UV-protective coating illuminated line selection keys with associated fields for labels integrated full range speaker and electret microphone incl. hexagon socket screw wrench SW5 for WFAK Call Stations and only: > Connector for 25 W Amplifier > Plug-in connector for built-in 1 W amplifier ( ) Functional Features line selection via keys line functions configurable from control centre individual gain adjustments of microphone and speaker amplification incoming call and line busy indication Art. No / / / Physical Data Number of line-keys 3 6 Weight (without auxiliary amplifier) approx. 2.3 kg approx. 2.1 kg Enclosure dimensions (H x W x D) 250 x 100 x 195 mm 250 x 100 x 150 mm Enclosure colour pure orange (RAL 2004) / golden yellow (RAL 1004) Electrical Data Supply voltage range V DC Max. quiescent current 30 ma Max. operating current approx. 100 ma Amplifier power rating 1 W Min. input voltage for rated power 100 mv Average speech power (1 W / 1 m) 86 db Frequency range 150 Hz to 10 khz Environmental Conditions Climate class per DIN EN K6 (extended temperature range -25 to +70 C) Protection class IP65 per DIN EN / IEC 529 Device group, category per 94/9/EG-RL II 3G and 3D 2006 ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 14

15 Weatherproof Digital Call Station (WFD) The Weatherproof Digital WFD Call Stations provide direct intercom connections to other call stations and PA loudspeaker announcements both outdoors and indoors in harsh environments, such as in heavy industry facilities. When the robust two-way toggle keys are pressed, they activate contactless opto-couplers, which make them suitable for permanent use in aggressive, moist environments. The call stations are designed for wall mounting, and they cannot be expanded with expansion enclosures. Equipment Features dust- and watertight, fiberglassreinforced polyester enclosure two-way toggle keys with opto-coupler, 2 lines each integrated pressure chamber loudspeaker and electret microphone connector for optional Auxiliary Amplifier WFD Call Station, 1 two-way toggle Art. No WFD Call Station, 2 two-way toggles Art. No WFD Call Station, 3 two-way toggles Art. No Functional Features direct intercom connections, keycontrolled can be switched to low volume (nighttime operation) LED indication of incoming call and line busy, prioritized functions configurable via MDK less wiring required Art. No Physical Data Number of two-way toggle keys Weight (without auxiliary amplifier) approx. 5.0 kg Enclosure dimensions (H x W x D) 500 x 120 x 180 mm Enclosure colour pure orange (RAL 2004) Electrical Data Supply voltage range V DC Max. quiescent current 25 ma Max. operating current approx. 125 ma Amplifier power rating 1 W Min. input voltage for rated power 150 mv Average speech power (1 W / 1 m) 86 db Frequency range 300 Hz to 7 khz (-3 to ±1 db) Communication protocol Neumann WL Protocol Environmental Conditions Climate class per DIN EN K6 (extended temperature range -25 to +70 C) Protection class per DIN EN / IEC 529 IP66 Device group, category per 94/9/EG-RL II 3G and 3D 2006 ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 15

16 WFD Accessories Article Description Art. No. Accessory Parts for WFD Call Station 25-W Auxiliary Amplifier 1) 25 W / 48/60 V DC Mounting kit adapter for drill holes of older call stations, incl. 2 angle brackets and 4 steel hexagon socket screws M6 x 18 Key insert two-way toggle keys for 2 Lines Blank panel instead of key insert Hexagon socket screw wrench SW5 for hexagon socket screws on enclosure panel ) Not included with WFD Call Stations Art. No , or ; for technical data, see pg ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 16

17 Explosion-Proof Call Stations Weatherproof Digital Call Station, Ex-Proof (WFD-EX) The explosion-proof, Weatherproof Digital WFD Call Stations provide direct intercom connections to other call stations and PA loudspeaker announcements in potentially explosive environments. When the robust two-way toggle keys are pressed, they activate contactless opto-couplers, which make them suitable for permanent use in aggressive, moist and dusty environments, especially in areas that are enriched with explosive gases and dust. The call stations are designed for wall mounting, and they cannot be expanded with expansion enclosures. Equipment Features dust- and watertight, fiberglassreinforced polyester enclosure two-way toggle keys with optocoupler, 2 lines each active components pressure-proof enclosed integrated pressure chamber loudspeaker and electret microphone connector for Auxiliary Amplifier WFD-EX Call Station, 1 two-way toggles Art. No as above, but with auxiliary amplifier 1) Art. No WFD-EX Call Station, 2 two-way toggles Art. No as above, but with auxiliary amplifier 1) Art. No WFD-EX Call Station, 3 two-way toggles Art. No as above, but with auxiliary amplifier 1) Art. No Functional Features direct intercom connections, keycontrolled can be switched to low volume (nighttime operation) LED indication of incoming call and line busy, prioritized functions configurable via MDK less wiring required Art. No / / / Physical Data Number of two-way toggle keys Weight (without auxiliary amplifier) approx. 6.5 kg Enclosure dimensions (H x W x D) 500 x 120 x 180 mm Enclosure colour pure orange (RAL 2004) Electrical Data Supply voltage range V DC Max. quiescent current 25 ma Max. operating current 100 ma Amplifier power rating 1 W Min. input voltage for rated power 150 mv Frequency range 300 Hz to 7 khz Communication protocol Neumann WL Protocol Environmental Conditions Climate class per DIN EN K6 (however, changed temperature range -20 to +70 C) Protection class per DIN EN / IEC 529 IP66 Ex-proof certification per EG-RL 94/9/EG II 2 G EEx d e ib IIC T4 (PTB 01 ATEX 2070) II 2 D IP66 T135 C (PTB EX ) 1) The 25-W Auxiliary Amplifier (Art. No ) is installed; for technical data, see pg ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 17

18 Weatherproof Analogue Call Station, Ex-Proof (WFA-EX) The explosion-proof, Weatherproof Analogue WFA Call Stations provide direct intercom connections to other call stations and PA loudspeaker announcements in potentially explosive environments. When the robust two-way toggle keys are pressed, they activate contactless opto-couplers, which make them suitable for permanent use in aggressive, moist and dusty environments, especially in areas that are enriched with explosive gases and dust. The call stations are designed for wall mounting, and they cannot be expanded with expansion enclosures. Equipment Features dust- and watertight, fiberglassreinforced polyester enclosure two-way toggle keys with optocoupler, 2 lines each active components pressure-proof enclosed integrated pressure chamber loudspeaker and electret microphone connector for Auxiliary Amplifier WFA-EX Call Station, 1 two-way toggle Art. No as above, but with auxiliary amplifier 1) Art. No WFA-EX Call Station, 2 two-way toggles Art. No as above, but with auxiliary amplifier 1) Art. No WFA-EX Call Station, 3 two-way toggles Art. No as above, but with auxiliary amplifier 1) Art. No Functional Features key-controlled line selection line functions configurable from control centre can be switched to low volume (nighttime operation) LED indication of incoming call and line busy, prioritized Art. No / / / Physical Data Number of two-way toggle keys Weight (without auxiliary amplifier) approx. 6.5 kg Enclosure dimensions (H x W x D) 500 x 120 x 180 mm Enclosure colour pure orange (RAL 2004) Electrical Data Supply voltage range V DC Max. quiescent current 10 ma Max. operating current approx. 50 ma Amplifier power rating 1 W Min. input voltage for rated power 150 mv Frequency range 300 Hz to 10 khz (-3 to ±1 db) Environmental Conditions Climate class per DIN EN K6 (altered temperature range -20 to +70 C) Protection class per DIN EN / IEC 529 IP66 Ex-proof certification per EG-RL 94/9/EG II 2 G EEx d e ib IIC T4 (PTB 01 ATEX 2070) II 2 D IP66 T135 C (PTB EX ) 1) The 25-W Auxiliary Amplifier (Art. No ) is installed; for technical data, see pg ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 18

19 WFD-EX/WFA-EX Accessories Article Description Art. No. Accessory Parts for WFD-EX/WFA-EX Call Station 25-W Auxiliary Amplifier 25 W / 48/60 V DC Mounting kit adapter for drill holes of older call stations, incl. 2 angle brackets and 4 steel hexagon socket screws M6 x 18 Key insert two-way toggle keys for 2 Lines Blank panel instead of key insert Hexagon socket screw wrench SW5 for hexagon socket screws on enclosure panel W Auxiliary Amplifier for WFA/WFD/WFD-EX/WFA-EX Call Stations A call station in combination with an auxiliary amplifier and loudspeaker can use the auxiliary loudspeaker as a PA speaker for incoming calls. Only the initial call to the call station is transmitted over the auxiliary loudspeaker. When the call station answers, its internal speaker is automatically used for the rest of the call. After approx. 20 seconds pause in the conversation, the call station returns to using the PA loudspeaker. 25-W Auxiliary Amplifier 1) Art. No Functional Features installable solder-free, on site temperature-controlled power limiter PA operation with separate auxiliary loudspeaker auxiliary loudspeaker can be switched off installable in the following call stations: WFA: Art. No , and WFD: Art. No , and WFD-EX: Art. No , and WFA-EX: Art. No , and already included in the following call stations: WFD-EX: Art. No , and WFA-EX: Art. No , and Art. No Electrical Data Supply voltage range V DC Max. quiescent current 10 ma Max. operating current approx. 900 ma Audio output power 25 W an 400 Ω Output voltage 100 V (can be changed to 50 V) Min. input voltage for rated power 1 V Input impedance 20 kω (at 1 khz) Frequency range (measured at Vo=25 V AC) 200 Hz to 10 khz (-3 to ±1 db) Distortion factor (measured at Vo=70 V AC) 5 % 1) When installing, we recommend using heat conducting paste, Art. No ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 19

20 Weatherproof Telephones Weatherproof Telephone with Keypad (WTAT) or without Keypad (WTA) The Weatherproof Analogue Telephone (WTAT), developed for connection to either the public telephone system or to private branch exchanges, is a reliable, modern communication device suitable for use under even the most rugged conditions. Its robust impact-resistant housing featuring a stainless steel keypad, which can still be easily operated while wearing work gloves, ensures maximal reliability under adverse conditions such as high-humidity or dusty environments, or where it can come into contact with alkalis or lubricants. The telephone has many convenience features including intuitive operation, easy programmability, and clearly readable alphanumeric display. The WTA model, designed for use in central exchange systems, is equivalent to the WTAT model except that it does not have a keypad or display. Weatherproof Analogue Telephone with Keypad (WTAT) Art. No Features Fibreglass-reinforced polyester housing Stainless steel keypad with ice protection ² ) 21-key keypad with standard ABC lettering to enter characters ² ) 2-line alphanumeric display with separate indicator symbols Vertical wall mounting Adjustable receiver securing mechanism integrated into cradle Stainless-steel armoured receiver cord Dynamic earpiece capsule with inductor coil for inductive coupling with hearing aids Electret microphone Noise suppression > 3dB due to special shape of mouthpiece W-terminals to connect an external incoming call indicator Terminals to connect an external loudspeaker Terminals to connect a headset (optional accessory) ¹ ) ² ) Terminals to connect a second earpiece (optional accessory) ¹ ) ² ) Terminals accept up to 4mm² solid core or up to 2.2 mm² stranded wire Features of the WTAT Receiver operation, loudspeaker listening, handsfree Phone number directory Dialling mode setting (pulse or touch tone) Pulse/space ratio setting for pulse dialling Setting for flash time Volume setting Key to put active call on hold Phone locked/pin code Contrast setting for LCD display Freely definable welcome text Select from 5 languages for menus Weatherproof Analogue Telephone without Keypad (WTA) Art. No Features of the ZB model (WTA) Line connection made by picking up receiver Integrated incoming call signalling ¹ ) Optional headset or second earpiece can be connected, but not both at the same time. ² ) Not applicable to ZB model ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 20

21 Art.-No Name WTAT WTA Housing Enclosure dimensions (H x W x D) 260 x 228 x 135 mm Weight approx. 5.5 kg Housing material fibreglass-reinforced polyester Keypad V4A-steel keypad - Display 2-line display, approx. 78 x 26mm - Enclosure colour black Electrical Data Operating voltage range V DC Input current 15 ma DC 100 ma DC Ringing AC voltage 24V AC to 90V AC (at 21-54Hz ringing frequency), 30V AC to 90V AC (at Hz ringing frequency) Ringing impedance > 6 kω at 25 Hz and 24-90V AC > 6 kω at 25 Hz and 24-90V AC Environmental Conditions Climate class per DIN EN K6 Protection class per DIN EN / IEC 529 IP66 per EN Protection rating against mechanical impact damage IK 09 per EN Ex-certified: 06 ATEX E 028 as per EC- RL 94/9/EC - Operating temperature in C -25 to +60, nothing shown on display below 20 Storage temperature in C -25 bis +70 per IEC ³ ) Prerequisite for T5: ambient temperature between -25 and +40 ⁴ ) Prerequisite for T6: ambient temperature between -25 and ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 21

22 Explosion-Proof Telephones Explosion-Proof Telephone with Keypad (WTAT) or without Keypad (WTA) The Analogue Explosion-Proof and Weatherproof Telephone (WTAT), developed for connection to either the public telephone system or to private branch exchanges, is a reliable, modern communication device suitable for use under even the most rugged conditions. Its robust impact-resistant, explosion-proof housing featuring a stainless steel keypad, which can still be easily operated while wearing work gloves, ensures maximal reliability under adverse conditions such as high-humidity or dusty environments, or where it can come into contact with alkalis or lubricants. The telephone has many convenience features including intuitive operation, easy programmability, and clearly readable alphanumeric display. The WTA model, designed for use in central exchange systems, is equivalent to the WTAT model except that it does not have a keypad or display. Explosionproof Analogue Telephone with Keypad (WTAT) Art. No Features Fibreglass-reinforced polyester housing Stainless steel keypad with ice protection ² ) 21-key keypad with standard ABC lettering to enter characters ² ) 2-line alphanumeric display with separate indicator symbols Encapsulation ex-protection Vertical wall mounting Adjustable receiver securing mechanism integrated into cradle Stainless-steel armoured receiver cord Dynamic earpiece capsule with inductor coil for inductive coupling with hearing aids Electret microphone Noise suppression > 3dB due to special shape of mouthpiece W-terminals to connect an external incoming call indicator Terminals to connect an external loudspeaker Terminals to connect a headset (optional accessory) ¹ ) ² ) Terminals to connect a second earpiece (optional accessory) ¹ ) ² ) Terminals accept up to 4mm² solid core or up to 2.2 mm² stranded wire Features of the WTAT Receiver operation, loudspeaker listening, handsfree Phone number directory Dialling mode setting (pulse or touch tone) Pulse/space ratio setting for pulse dialling Setting for flash time Volume setting Key to put active call on hold Phone locked/pin code Contrast setting for LCD display Freely definable welcome text Select from 5 languages for menus Explosionproof Analogue Telephone without Keypad (WTA) Art. No Features of the ZB model (WTA) Line connection made by picking up receiver Integrated incoming call signalling ¹ ) Optional headset or second earpiece can be connected, but not both at the same time. ² ) Not applicable to ZB model ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 22

23 Art.-No Name WTAT-EX WTA-EX Housing Enclosure dimensions (H x W x D) 260 x 228 x 135 mm Weight approx. 5.5 kg Housing material fibreglass-reinforced polyester Keypad V4A-Steel Keyboard - Display 2-line display, approx. 78 x 26mm - Enclosure colour black Electrical Data Operating voltage range V DC Input current 15 ma DC 100 ma DC Ringing AC voltage 24V AC to 90V AC (at 21-54Hz ringing frequency) 30V AC to 90V AC (at Hz ringing frequency) Ringing impedance > 6 kω at 25 Hz and 24-90V AC > 6 kω at 25 Hz and 24-90V AC Environmental Conditions Climate class per DIN EN K6 (exclusion for T6) Protection class IP66 per DIN EN Protection rating against mechanical impact damage IK 09 per EN Ex-certified: 06 ATEX E 028 as per EC-RL 94/9/EC Operating temperature in C II 2G EEx em ib IIC T5 II 2D IP66 T100 C ³ ) / II 2G EEx em ib IIC T6 II 2D IP66 T80 C ⁴ ) -25 to +60 (for T5) -25 to +40 (for T6) nothing shown on display below 20 Storage temperature in C -25 to +70 per IEC ³ ) Prerequisite for T5: ambient temperature between -25 and +40 ⁴ ) Prerequisite for T6: ambient temperature between -25 and ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 23

24 Technical Details IP Rating of Enclosures As per DIN / IEC / VDE 0470 / EN International standards classify the type of protection an enclosure provides by using a two-digit IP (International Protection) code that indicates the degree of protection the enclosure provides against the penetration of foreign objects, dust and water. A typical IP number for weatherproof enclosures is, for example, IP65 1). 1st Digit of Degree of protection against the penetration of 2nd Digit of Degree of protection against water IP Code solid foreign objects and hazardous access IP Code 0 No protection 0 No protection 1 Protected against the penetration of large foreign objects with a diameter greater than 50 mm 2 Protected against the penetration of mediumsized foreign objects with a diameter greater than 12 mm 3 Protected against the penetration of small foreign objects with a diameter greater than 2.5 mm 4 Protected against the penetration of tools, wire (particulate foreign objects) with a diameter greater than 1.0 mm 5 Completely protected against access to hazardous voltage carrying parts and internal moving parts. Protected against harmful accumulation of dust. Penetration of dust is not entirely prevented, but it must not be to an extent that would impair proper functioning. 6 Completely protected against access to hazardous voltage carrying parts and internal moving parts. Protected against the penetration of dust. 1 Protected against the ingress of vertically falling water drops 2 Protected against water drops falling at an angle of up to 15º from the vertical 3 Protected against water sprayed at any angle up to 60º from the vertical 4 Protected against water splashing against the enclosure from any direction 5 Protected against water jets sprayed through a nozzle against the enclosure from any direction 6 Protected against powerful water jets or temporary flooding (heavy seas) 7 Protected against temporary immersion in water under defined conditions of time and pressures corresponding to depths between 0.15 and 1 m 8 Protected against continuous submersion in water 9K Protected against water sprayed from highpressure water or steam cleaning jets directed at the enclosure from any direction 1 ) If an IP protection rating is not specified for one of the two categories, then the letter X is used instead of the respective digit, e.g. IPX ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 24

25 General Information on the Designation of Explosion-Proof Equipment The designation of electrical equipment and protection systems when put to their intended use in potentially explosive areas is determined according to the requirements of EC Directive 94/9/EC. The following is an example: II 2G EEx d e ib IIC T4 Explanation: 1. Zones / Equipment Groups / Equipment Categories There are 2 Equipment Groups: the designation I is assigned to electrical equipment for use in underground mining, the designation II for use in surface industries. The areas in which there is a risk of explosion are divided into Zones according to the likelihood of a potentially explosive atmosphere being present. In each Zone, the proper equipment must be used according to the Equipment Category (area of usage). The current IEC regulation defines the following Zones: Classification of Hazardous Areas / Equipment Categories / Equipment Groups Combustible Materials G: Gases, Vapours, Fumes D: Dusts M: Methane/Dust Characteristic for the Explosive Mixture Present continuously or frequently or for long periods Likely to occur in normal operation Not likely to occur in normal operation and if it occurs it will exist only for a short time Present continuously or frequently or for long periods Likely to occur in normal operation Swirled up dust not likely to occur in normal operation and if it occurs it will exist only for a short time Zones Equipment Group (for use in surface industries or underground) Zone 0 II 1G Equipment Category Zone 1 II 2G (also 1G) Zone 2 Zone 20 II 1D II 3G (also 2G and 1G) Zone 21 II 2D (also 1D) Zone 22 II 3D (also 2D and 1D) - M1 Mining I - M2 or M1 Explosion Subgroups: Classification of Gases and Vapours Equipment Group II is divided into three Gas Groups where IIA is the least volatile and Group IIC the most volatile. North America uses a differing classification according to Classes (I, II, III): Class I refers to gases and vapours (see table). Explosion Subgroups / Typical Gases CENELEC / IEC Typical Gases U.S.A. and Canada I IIA IIB IIC IIC Methane Propane, n-butane, Kerosene Ethylene, Hydrogen sulphide, Ethyl ether Hydrogen, Acetylene, Carbon disulphide Hydrogen, Acetylene, Carbon disulphide no classification Class I, Group D Class I, Group C Class I, Group B Class I, Group A 2006 ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 25

26 2. Types of Explosion Protection To enable electrical equipment to be used in areas where there is a risk explosion, various explosion protection techniques must be employed to prevent the equipment from igniting explosive atmospheres. Different techniques are used depending on the application and equipment: exclusion of the explosive atmosphere (o, q, m), purged and pressurized (p), containment of internal explosion (d), special mechanical designs (n, e), limiting electrical energy (ia, ib), as well as other measures (s). Each of these techniques is subject to national and/or international standards and regulations. EEx: Explosion Protection certified according to CENELEC Standard EN 50 Explosion Protection certified according to CENELEC Standard EN 50 corresponds to the relevant IEC standards and stipulates equipment safety measures that guarantee at least the same degree of safety as the European standards. Type of Protection / Technique / CENELEC Standard / IEC Standard Designation Type of Protection Technique CENELEC IEC General Requirements for all methods EN EEx d Flameproof Enclosure Enclosure contains internal explosion preventing it from igniting surrounding explosive EN atmosphere EEx e Increased Safety Special mechanical design EN EEx p Purged and Pressurized EN Source of ignition is kept EEx m Encapsulation EN isolated from explosive EEx o Oil Immersion EN atmosphere EEx q Powder Filling EN EEx n Non-sparking (na) / Restricted breathing (nr) Special mechanical design (only for Zones 2 and 22) EEx i* (ia, ib) Intrinsic Safety Energy limitation EN 50020** EN 50039*** Other methods that do not EEx s Special Protection conform to the standard protection methods * The protection type Intrinsic Safety is subdivided into the categories ia and ib. ** Equipment *** Systems EN Classification into Temperature Classes Hot surfaces can also ignite gas/air mixtures when the equipment s surface temperature reaches the ignition temperature of the potentially explosive atmosphere. To guard against this, all electrical equipment intended for use in a potentially explosive atmosphere is classified according to the maximum surface temperature it will reach in service. Temperature Classes Maximum surface temperature of electrical equipment in C T1 > 450 T2 T3 T4 T5 T6 > 300 to 450 C > 200 to 300 C > 135 to 200 C > 100 to 135 C > 85 to 100 C ms Neumann Elektronik GmbH owns a registered trademark (brand). Other products and company names mentioned herein are trademarks or registered trademarks of their respective owners. Printing errors, errors, technical or any other changes, as well as changes in the availability of individual products are to be expressly expected. ms Neumann Elektronik GmbH, ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue 03 26

27 2006 ms NEUMANN ELEKTRONIK GMBH All rights reserved Issue Mainstr. 1, Mülheim a.d. Ruhr, Germany, Ph: +49/208/5995-0, FAX: +49/208/ , info@neumann-elektronik.com

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series Features and Functions For use in explosive (hazardous) areas of Ex zone 1 and 2 Equipment group and category Ex II 2G Temperature range of DX

More information

Digital Outdoor Intercom Station DA/DAE 0x5 Series

Digital Outdoor Intercom Station DA/DAE 0x5 Series Digital Outdoor Intercom Station DA/DAE 0x5 Series Features and Functions Robust construction for use in harsh industrial environments Degree of protection IP66 Glass-fiber reinforced polyester Configurable

More information

Serverless Page/Party

Serverless Page/Party Serverless Page/Party VoIP Multicast Paging and Intercom is GAI-Tronics most advanced paging and intercom system yet. Combining the simplicity of press to page, release to party operation with cutting-edge

More information

Speaking Station LV30

Speaking Station LV30 Speaking Station LV30 Ordering data Designation Type Item no. Speaking station with cable entries LV 30 300 0 AX Speaking station with plug connectors (socket / socket) Speaking station with plug connectors

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

AP 701 Access Panel. Features and Functions

AP 701 Access Panel. Features and Functions AP 701 Access Panel Features and Functions IP desktop intercom station for use in control rooms, control centers, or measuring stations Resistive color touch display for flexible operation with finger,

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Explosion-proof telephone

Explosion-proof telephone Explosion-proof telephone Operating instructions FHF BA9701-24 12/13 Foreword Our explosion-proof, weatherpoof phone offers precision, comfort, extended service life and reliability. It is programmable

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Digital Intercom Stations DTM Series

Digital Intercom Stations DTM Series Digital Intercom Stations DTM Series Features and Functions Digital intercom stations for indoor use Different designs with up to 60 keys available DTM 110 with interface for handset connection LCD display

More information

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 430 FOUR CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 SIDE PANEL CONNECTORS...

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 230 DUAL CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 SIDE PANEL CONNECTORS...

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System Description The issue of security is more than ever

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Safety instructions Overvoltage protection B81-35

Safety instructions Overvoltage protection B81-35 Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Weatherproof telephone

Weatherproof telephone Weatherproof telephone ZB version Operating manual FHF BA 9605-10 11/11 Note Please read the operating manual carefully before installing the device. Please check the contents of the box for completeness.

More information

Explosive atmospheres occur when flammable gases, mist, vapors or dust are mixed with air. This creates a risk of explosion.

Explosive atmospheres occur when flammable gases, mist, vapors or dust are mixed with air. This creates a risk of explosion. Explosive atmospheres occur when flammable gases, mist, vapors or dust are mixed with air. This creates a risk of explosion. The amount of a substance needed to create an explosive atmosphere depends on

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

APM. User manual & Installation guide. Digital paging microphone.

APM. User manual & Installation guide. Digital paging microphone. APM User manual & Installation guide Digital paging microphone www.audac.eu 2 Index 3 Introduction 5 Precautions 6 Chapter 1: Overview of APM1xx 9 Indicator LED functions 11 Button functions 12 Chapter

More information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:

More information

STENTOFON PULSE SERVERLESS INTERCOM

STENTOFON PULSE SERVERLESS INTERCOM STENTOFON PULSE SERVERLESS INTERCOM STENTOFON began life in 1946 as Stentor Radiofabrikk, specializing in radio communication systems for ships and fishing boats. Stentor later extended its range with

More information

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12

Explosion proof UL certified VoIP telephone. FernTel IP Z2 UL. Tabletop unit. Manual FHF BA /12 Explosion proof UL certified VoIP telephone FernTel IP Z2 UL Tabletop unit Manual FHF BA 9620-51 09/12 BA 9620-51 09 /12 FernTel IP Z2 UL Manual Brand names are used with no guarantee that they may be

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Pressure sensors SDE3, with display

Pressure sensors SDE3, with display Pressure sensors SDE3 Key features At a glance SDE3- -M plug version, plug M8x1 and M12x1 SDE3- -FQ, cable with plug Fast H-rail, wall or surface mounting Fast front panel mounting High-contrast, two-colour

More information

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order #

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order # Digital Delegate Microphone Unit with Loudspeaker Order # 725.706 Supplied without gooseneck microphone FEATURES Coated plastic housing with metal bottom plate Inserts made of optically hardened acrylic

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System The issue of security is more than ever important.

More information

Cordless Telephones for HiPath Systems

Cordless Telephones for HiPath Systems s Cordless Telephones for HiPath Systems Alongside the system-specific HiPath telephones, Siemens offers additional cordless phones that can be operated on the HiPath systems. These cordless phones will

More information

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX Panel PC for panel- mounting, quad core ATOM E3845 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Isolating repeater IRU 420

Isolating repeater IRU 420 Isolating repeater IRU 420 Universal intrinsically safe isolating repeater of current signals 0/4 20 ma with option voltage output 0 10 V For supply sensors with output 0/4 20 ma in Galvanic separation

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

DVS-21 product catalogue 2015 V1.03. Table of contents:

DVS-21 product catalogue 2015 V1.03. Table of contents: Table of contents: 1. Generally... 4 2. GGS DVS21 19 Mainrack with standby function... 5 3. GG1-2 DVS21 19 Mainrack... 5 4. GG2-2 DVS21 19 Mainrack... 5 5. EG1 DVS21 19 expansion rack... 5 6. EG3 DVS21

More information

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX Operator Interface for panel mounting 15" display, 1024 x 768 pixels with resistive foil touch screen 8 function keys Zone 2, 22 und Division 2, can be installed in hazardous areas without additional enclosure

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 630 SIX CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 REAR PANEL CONNECTORS...

More information

(DISTRIBUTED AMPLIFIER BASED DESIGN) (NON BLOCKING TYPE).

(DISTRIBUTED AMPLIFIER BASED DESIGN) (NON BLOCKING TYPE). (DISTRIBUTED AMPLIFIER BASED DESIGN) (NON BLOCKING TYPE). SMART INDUSTRIAL PA SYSTEM (MODEL MCS II) Distributed Amplifier Design Concept INDUSTRIAL PA SYSTEM with unique features of MULTIPLE PAGE CHANNELS

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

Page Station Module Replacements Page/Talk, Page/Party & Third-Party

Page Station Module Replacements Page/Talk, Page/Party & Third-Party G U A R D I A N T E L E C O M Product and Services Guide Page Station Module Replacements Page/Talk, Page/Party & Third-Party When it s time to replace your current Page/Talk, Page/Party or other Third-Party

More information

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order # Digital Flush Mount Delegate Microphone Unit Order # 725.722 Optional CA OL loudspeaker module, not included Table installation supplied without gooseneck microphone FEATURES High-quality flush mounting

More information

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016 PS 150 SINGLE CHANNEL TELEPHONE INTERFACE USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

PC100 - Concept. Advantages in comparison

PC100 - Concept. Advantages in comparison PC100 - Concept The future of HMI-devices for the use in explosion endangered areas is less based on short lived proprietary products but more on all-purpose, modular products of latest technology and

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Explosion-proof telephone

Explosion-proof telephone Explosion-proof telephone Operating instructions FHF BA 9701-23 03/12 Foreword Our explosion-proof, weather-resistant telephone is a captivating product on account of its precision, convenience, long service

More information

STENTOFON PRO700 ExchangElEss IntERcOm

STENTOFON PRO700 ExchangElEss IntERcOm STENTOFON PRO700 Exchangeless Intercom STENTOFON PRO700 exchangeless intercom Used daily by thousands of businesses, public service buildings and security companies throughout the world, there isn't a

More information

Background. ii) Noise cancelling microphone. iii) Headset with integral boom microphone. iv) Headset jacking socket box. v) Telephone style handset

Background. ii) Noise cancelling microphone. iii) Headset with integral boom microphone. iv) Headset jacking socket box. v) Telephone style handset MT50 TALKBACK TDS-033 Issue 01 Ziztel Technical Bulletin Thank you for your interest in Ziztel - we are a UK based manufacturer of PAGA and Intercom products. Our systems are mainly designed for use in

More information

Data sheet C6 A modul 1 port 180 M AP pure white

Data sheet C6 A modul 1 port 180 M AP pure white Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS OPERATING INSTRUCTIONS INFORMATION AMPLIFIER TA-102 INFORMATION AMPLIFIER TA-102 MIC AUX POWER TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 4 3. EACH PART NAME AND FUNCTIONS Top

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071 www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or

More information

CL210A TELEPHONE & ANSWERING MACHINE

CL210A TELEPHONE & ANSWERING MACHINE CL210A TELEPHONE & ANSWERING MACHINE CONTENTS CONTENTS CONTENTS 1 INTRODUCTION 3 Unpacking the Telephone 4 DESCRIPTION 5 General Description 5 INSTALLATION 7 Setting Up 7 Wall Mounting 7 SETTINGS 8 Ringer

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System The issue of security is more than ever important.

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued! EElectronic Devices and Systems EK-87 Electronic Volume Corrector This product is discontinued! In brief EK-87 electronic volume corrector System volume corrector including integrated data storage device

More information

SolConeX Wall-Mounted Socket, 16 A

SolConeX Wall-Mounted Socket, 16 A SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the

More information

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...) 7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which

More information

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters Edition November 2003 Information Sheet T 6000 EN Proportional valves e/p Converters Type 6 66 626

More information

Headset, 1 speaker Headset, 2 speakers Microphone standby position. Headset, in-use position Headset, standby position Connecting plug, headset to PTT

Headset, 1 speaker Headset, 2 speakers Microphone standby position. Headset, in-use position Headset, standby position Connecting plug, headset to PTT Communication Accessories Flexible Microphone Headset, Gallet F1 XF helmet Communication headset for integration in Gallet F1 XF fire helmet One or two loudspeakers, in plastic housing with mounting clips.

More information

Linear Luminaire with LED Series 6412/5

Linear Luminaire with LED Series 6412/5 > For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information