Soloist CP Hardware Manual

Size: px
Start display at page:

Download "Soloist CP Hardware Manual"

Transcription

1 Hardware Manual Revision: ENB/FLT MARKER PWR INPOS ENB/FLT MARKER PWR INPOS TB0 AGND AIN AIN- AOUT ETHERNET J0 ETHERNET J0 OP OM OPTO OUT TB0 MOTOR FEEDBACK J03 TM MOTOR FEEDBACK J03 OP OM OPTO OUT TB03 AEROTECH. COM TM ESTOP TB0 ESTOP TB0 AEROTECH. COM 40V~ MAX 50/60Hz 5A MAX MOTOR SUPPLY MOTOR OUTPUT AC AC A B C AUX I/O J04 TB0 DANGER! High Voltage AUX I/O J04 40V~ MAX 50/60Hz 5A MAX MOTOR SUPPLY MOTOR OUTPUT AC AC A B C DANGER! High Voltage TB0 C GND C V NC C NO OPTO IN TB04 OPTO IN TB05 RELAY TB06

2 Global Technical Support Go to for information and support about your Aerotech products. The website provides downloadable resources (such as up-to-date software, product manuals, and Help files), training schedules, and PC-to-PC remote technical support. You can also complete Product Return (RMA) forms and get information about repairs and spare or replacement parts. For immediate help, contact a service office or your sales representative. Have your customer order number available before you call or include it in your . Phone: Fax: service@aerotech.com United Kingdom Phone: 44 (0) Fax: 44 (0) service@aerotech.co.uk Germany Phone: 49 (0) Fax: 49 (0) service@aerotechgmbh.de France Phone: sales@aerotech.co.uk United States (World Headquarters) 0 Zeta Drive Pittsburgh, PA Japan Phone: 8 (0) Fax: 8 (0) service@aerotechkk.com.jp China Phone: 86 () saleschina@aerotech.com Taiwan Phone: 886 (0) service@aerotech.tw This manual contains proprietary information and may not be reproduced, disclosed, or used in whole or in part without the express written permission of Aerotech, Inc. Product names mentioned herein are used for identification purposes only and may be trademarks of their respective companies. Copyright , Aerotech, Inc., All rights reserved.

3 Table of Contents Table of Contents Hardware Manual Table of Contents 3 List of Figures 5 List of Tables 7 EU Declaration of Conformity 9 Agency Approvals 0 Safety Procedures and Warnings Quick Installation Guide 3 Chapter : Introduction 5.. Drive and Software Compatibility 8.. Electrical Specifications 9... System Power Requirements 0... Power Dissipation.3. Mechanical Design.4. Environmental Specifications 3 Chapter : Installation and Configuration 5.. Power Connections 5... Control Supply Connections (TB06) 6... Motor Supply Connections (TB0) Transformer Options Minimizing Conducted, Radiated, and System Noise 35.. Motor Output Connections Brushless Motor Connections Powered Motor Phasing Unpowered Motor and Feedback Phasing DC Brush Motor Connections DC Brush Motor Phasing Stepper Motor Connections Stepper Motor Phasing Motor Feedback Connections (J03) Encoder Interface (J03) RS-4 Line Driver Encoder (Standard) EnDat Encoder Interface (J03) Resolute Encoder Interface (J03) Analog Encoder Interface Encoder Phasing Hall-Effect Interface (J03) Thermistor Interface (J03) Encoder Fault Interface (J03) End Of Travel Limit Input Interface (J03) End Of Travel Limit Phasing Brake Output (J03) Emergency Stop Sense Input (TB0) Typical ESTOP Interface 6.5. Auxiliary I/O Connector (J04) Auxiliary Encoder Channel (J04) Position Synchronized Output (PSO)/Laser Firing (J04) Opto-Isolated Outputs (J04) Opto-Isolated Inputs (J04) High-Speed User Inputs 4-5 (J04) Analog Output 0 (J04) 7 3

4 Table of Contents.5.7. Differential Analog Input 0 (J04) Brake Power Supply (TB03) Solid State Relay Specifications (TB03) RS-3 Interface (TB03) EXTSHUNT Option (TB04) PC Configuration and Operation Information 8 Chapter 3: -I/O Expansion Board Analog Output (TB0) Analog Input (TB0) Opto-Isolated Inputs (TB04, TB05) Opto-Isolated Outputs (TB0, TB03) User Power (TB04, TB05) Brake / Mechanical Relay (TB06) Brake Configuration Jumpers Mechanical Relay Specifications Brake / Mechanical Relay Interface Connector 95 Chapter 4: Standard Interconnection Cables Joystick Interface Handwheel Interface 0 Chapter 5: Maintenance Control Board Preventative Maintenance 08 Appendix A: Warranty and Field Service 09 Appendix B: Revision History Index 3 4

5 Table of Contents List of Figures Figure -: Networked Digital Drive 5 Figure -: Functional Diagram 7 Figure -3: Power Dissipation vs. Output Current Figure -4: Ambient Temperature vs. Power Dissipation Figure -5: Dimensions Figure -: Control Supply Connections 6 Figure -: Motor Bus Input Connections 7 Figure -3: Transformer Examples 8 Figure -4: 40 VDC Motor Power with a TV ST Transformer 9 Figure -5: 80 VDC Motor Power with a TV ST Transformer 30 Figure -6: 40 Volt DC Bus from 5 and 30 VAC Source 3 Figure -7: 80 Volt DC Bus from 5 and 30 VAC Source (TV0.3-56) 3 Figure -8: 60 Volt DC Bus from 5 and 30 VAC Source (TV0.3-56) 33 Figure -9: Control and Motor Power Wiring using a TM3 or TM5 Transformer 34 Figure -0: AC Line Filter (UFM-ST) 35 Figure -: Brushless Motor Configuration 37 Figure -: Encoder and Hall Signal Diagnostics 38 Figure -3: Motor Phasing Oscilloscope Example 39 Figure -4: Brushless Motor Phasing Goal 39 Figure -5: DC Brush Motor Configuration 40 Figure -6: Clockwise Motor Rotation 4 Figure -7: Stepper Motor Configuration 4 Figure -8: Clockwise Motor Rotation 43 Figure -9: Line Driver Encoder Interface (J03) 46 Figure -0: Serial Data Stream Interface 47 Figure -: Serial Data Stream Interface 48 Figure -: Analog Encoder Phasing Reference Diagram 49 Figure -3: Analog Encoder Interface (J03) 50 Figure -4: Encoder Phasing Reference Diagram (Standard) 5 Figure -5: Position Feedback in the Diagnostic Display 5 Figure -6: Hall-Effect Inputs (J03) 53 Figure -7: Thermistor Interface Input (J03) 54 Figure -8: Encoder Fault Interface Input (J03) 55 Figure -9: End of Travel Limit Input Connections 56 Figure -30: End of Travel Limit Interface Input (J03) 57 Figure -3: Limit Input Diagnostic Display 58 Figure -3: ESTOP Sense Input (TB0) 60 Figure -33: Typical Emergency Stop Circuit 6 Figure -34: Auxiliary Encoder Channel (J04) 64 Figure -35: PSO Interface 66 Figure -36: Outputs Connected in Current Sourcing Mode (J04) 68 Figure -37: Outputs Connected in Current Sinking Mode (J04) 68 Figure -38: Inputs Connected in Current Sourcing Mode (J04) 70 Figure -39: Inputs Connected in Current Sinking Mode (J04) 70 Figure -40: High-Speed User Inputs (J04) 7 Figure -4: Analog Output 0 (J04) 7 Figure -4: Analog Input 0 (J04) 73 Figure -43: Brake Connected to J03 75 Figure -44: Brake Connected to TB03 76 Figure -45: RS-3 Interface (TB03) 78 Figure 3-: with -IO Option Board

6 Table of Contents Figure 3-: Analog Output Connector (TB0) 84 Figure 3-3: Analog Input Typical Connection (TB0) 85 Figure 3-4: Opto-Isolated Inputs 87 Figure 3-5: Inputs Connected to a Current Sourcing Device 88 Figure 3-6: Inputs Connected to a Current Sinking Device 88 Figure 3-7: Opto-Isolated Outputs (-IO Board) 9 Figure 3-8: Outputs Connected in Current Sourcing Mode 9 Figure 3-9: Outputs Connected in Current Sinking Mode 9 Figure 3-0: Brake Connected to J03 96 Figure 3-: Brake Connected to TB06 96 Figure 4-: Single Axis Joystick Interface (to Aux I/O) 98 Figure 4-: Two Axis Joystick Interface (to the Aux I/O of two drives) 99 Figure 4-3: Two Axis Joystick Interface (to the Aux I/O and I/O Board) 00 Figure 4-4: Two Axis Joystick Interface (to the I/O board of two drives) 0 Figure 4-5: Handwheel Interconnection (to Aux I/O) 0 Figure 4-6: Handwheel Interconnection (to Aux I/O via a BBA3 Module) 03 Figure 5-: Control Board Assembly

7 Table of Contents List of Tables Table -: Feature Summary 6 Table -: Drive and Software Compatibility 8 Table -3: Electrical Specifications 9 Table -4: Physical Specifications Table -: Control Supply AC Input Wiring 6 Table -: Control Supply Mating Connector 6 Table -3: Motor Supply Mating Connector 7 Table -4: Nominal Motor Operating Voltages / Required AC Voltages 8 Table -5: Transformer Options 8 Table -6: Ferrite Noise Suppression Numbers 35 Table -7: UFM-ST Electrical Specifications 35 Table -8: Motor Power Output Connections (TB0) 36 Table -9: Motor Power Output Mating Connector 36 Table -0: Wire Colors for Aerotech Supplied Cables (Brushless) 37 Table -: Wire Colors for Aerotech Supplied Cables (DC Brush) 40 Table -: Wire Colors for Aerotech Supplied Cables (Stepper) 4 Table -3: Motor Feedback Connector Pin Assignment (J03) 44 Table -4: Encoder Interface Pin Assignment 45 Table -5: Encoder Specifications 46 Table -6: Analog Encoder Specifications 49 Table -7: Hall-Effect Feedback Interface Pin Assignment (J03) 53 Table -8: Thermistor Interface Pin Assignment (J03) 54 Table -9: Encoder Fault Interface Pin Assignment (J03) 55 Table -0: End of Travel Limit Input Interface Pin Assignment (J03) 56 Table -: Brake Output Pin Assignment (J03) 59 Table -: Electrical Noise Suppression Devices 60 Table -3: TB0 Mating Connector 60 Table -4: Typical ESTOP Relay Ratings 6 Table -5: Auxiliary I/O Connector Pin Assignment (J04) 6 Table -6: Auxiliary Encoder Specifications 63 Table -7: Auxiliary Encoder Channel Pin Assignment (J04) 63 Table -8: PSO Specifications 65 Table -9: PSO Output Pin Assignment (J04) 65 Table -30: Digital Output Specifications 67 Table -3: Port 0 Digital Output Connector Pin Assignment (J04) 67 Table -3: Opto-Isolated Input Specifications 69 Table -33: Port 0 Digital Input Connector Pin Assignment (J04) 69 Table -34: High-Speed Input Specifications 7 Table -35: Port 0 High Speed Digital Input Connector Pin Assignment (J04) 7 Table -36: Input Voltage Jumper Configuration 7 Table -37: Analog Output 0 Specifications (TB0 B) 7 Table -38: Analog Output Connector Pin Assignment (J04) 7 Table -39: Differential Analog Input 0 Specifications 73 Table -40: Analog Input Connector Pin Assignment (J04) 73 Table -4: Brake Output Connector Pin Assignment (TB03) 74 Table -4: Mating Connector (TB03) 74 Table -43: Brake Output Connector Pin Assignment (J03) 74 Table -44: Relay Specifications 77 Table -45: RS-3 Connector Pin Assignment (TB03) 78 Table -46: RS-3 Port Connector Mating Connector (TB03) 78 Table -47: -EXTSHUNT Component Information

8 Table of Contents Table -48: Maximum Storage Energy 80 Table 3-: -IO Expansion Board Jumper Configuration 83 Table 3-: -IO Option Board Fuse Information 83 Table 3-3: Analog Output Specifications (TB0 B) 84 Table 3-4: Analog Output Connector Pin Assignment (TB0) 84 Table 3-5: Analog Output Mating Connector 84 Table 3-6: Differential Analog Input Specifications 85 Table 3-7: Analog Inputs Connector Pin Assignment (TB0) 85 Table 3-8: Analog Input Mating Connector 85 Table 3-9: Opto-Isolated Input Device Specifications 86 Table 3-0: Port Opto-Isolated Input Connector Pin Assignment (TB04) 86 Table 3-: Port Opto-Isolated Input Connector Pin Assignment (TB05) 86 Table 3-: Opto-Isolated Input Mating Connector 86 Table 3-3: Output Specifications (TB0, TB03) 89 Table 3-4: Port Opto-Isolated Output Connector Pin Assignment (TB0) 90 Table 3-5: Port Opto-Isolated Output Connector Pin Assignment (TB03) 90 Table 3-6: Opto-Isolated Output Mating Connector 90 Table 3-7: User Common Connector Pin Assignment (TB04) 93 Table 3-8: 5 Volt Power Connector Pin Assignment (TB05) 93 Table 3-9: -IO Expansion Board Brake Jumper Configuration 94 Table 3-0: Voltage and Current Specifications (TB06) 94 Table 3-: Brake / Mechanical Relay Connector Pin Assignment (TB06) 95 Table 3-: Mating Connector for TB06 95 Table 3-3: Brake / Mechanical Relay Connector Pin Assignment (J03) 95 Table 4-: Standard Interconnection Cables 97 Table 4-: Cable Part Numbers 0 Table 5-: LED Description 05 Table 5-: Control Board Jumper Configuration 07 Table 5-3: Control Board Fuse Information 07 Table 5-4: LED Description 07 Table 5-5: Preventative Maintenance

9 Declaration of Conformity EU Declaration of Conformity Manufacturer Address Product Model/Types Aerotech, Inc. 0 Zeta Drive Pittsburgh, PA USA All This is to certify that the aforementioned product is in accordance with the applicable requirements of the following Directive(s): 04/30/EU 04/35/EU 0/65/EU Electromagnetic Compatibility Directive Low Voltage Directive LVD RoHS Directive and has been designed to be in conformity with the applicable requirements of the following documents when installed and used in accordance with the manufacturer s supplied installation instructions. EN 550:998 EN :004 EN :000 EN :995 EN :995 EN :00 EN :995 EN :995 EN :996 EN :994 EN 600-:00 RFI Limits and Measurement EMC requirements for power drives Harmonic Current Emissions Voltage Fluctuation and Flicker ESD Immunity Radiated RFI/EMI Immunity EFT/Burst Immunity Surge Immunity Conducted Immunity Voltage Dips and Interruptions Safety requirements for electrical equipment Name Position Location / Alex Weibel Engineer Verifying Compliance Pittsburgh, PA 9

10 Declaration of Conformity Agency Approvals Aerotech, Inc. Model Series Digital Drives have been tested and found to be in accordance to the following listed Agency Approvals: Approval / Certification: CUS NRTL Approving Agency: TUV SUD America Inc. Certificate #: U Standards: UL 600-:004; CAN/CSA-C. No. 600-:004; EN 600- :00 0

11 Electrical Safety Safety Procedures and Warnings The following statements apply wherever the Warning or Danger symbol appears within this manual. Failure to observe these precautions could result in serious injury to those individuals performing the procedures and/or damage to the equipment. N O T E : Read this manual in its entirety before installing, operating, or servicing this product. If you do not understand the information contained herein, contact an Aerotech representative before proceeding. Strictly adhere to the statements given in this section and other handling, use, and operational information given throughout the manual to avoid injury to you and damage to the equipment. N O T E : Aerotech continually improves its product offerings; listed options may be superseded at any time. All drawings and illustrations are for reference only and were complete and accurate as of this manual s release. Refer to for the most up-to-date information. D A N G E R : This product contains potentially lethal voltages. To reduce the possibility of electrical shock, bodily injury, or death the following precautions must be followed.. Disconnect electrical power before servicing equipment.. Disconnect electrical power before performing any wiring. 3. Access to the and component parts must be restricted while connected to a power source. 4. To minimize the possibility of electrical shock and bodily injury, extreme care must be exercised when any electrical circuits are in use. Suitable precautions and protection must be provided to warn and prevent persons from making contact with live circuits. 5. Install the inside a rack or enclosure. 6. The shunt resistor temperature can exceed 70 C during normal operation and contains lethal voltage on its terminals and surface. It must be properly enclosed and shielded to avoid risk of fire and operator shock. 7. Do not connect or disconnect any electrical components or connecting cables while connected to a power source. 8. All components must be properly grounded in accordance with local electrical safety requirements. 9. Operator safeguarding requirements must be addressed during final integration of the product. D A N G E R : The case temperature may exceed 70 C in some applications.

12 Electrical Safety W A R N I N G : To minimize the possibility of electrical shock, bodily injury or death the following precautions must be followed.. Use of this equipment in ways other than described by this manual can cause personal injury or equipment damage.. Moving parts can cause crushing or shearing injuries. Access to all stage and motor parts must be restricted while connected to a power source. 3. Cables can pose a tripping hazard. Securely mount and position all system cables to avoid potential hazards. 4. Do not expose this product to environments or conditions outside of the listed specifications. Exceeding environmental or operating specifications can cause damage to the equipment. 5. If the product is used in a manner not specified by the manufacturer, the protection provided by the product can be impaired and result in damage, shock, injury, or death. 6. Operators must be trained before operating this equipment. 7. All service and maintenance must be performed by qualified personnel. 8. This product is intended for light industrial manufacturing or laboratory use. Use of this product for unintended applications can result in injury and damage to the equipment.

13 Quick Installation Guide Quick Installation Guide This chapter describes the order in which connections and settings should typically be made to the Soloist CP. If a custom interconnection drawing was created for your system (look for a line item on your Sales Order under the heading Integration ), that drawing can be found on your installation device. ENB/FLT MARKER PWR INPOS TB0 AGND AIN AIN- AOUT WARNING: DISCONNECT POWER BEFORE SERVICING HAZARDOUS VOLTAGES PRESENT UP TO 8 MIN. AFTER POWER IS DISCONNECTED ETHERNET J0 MOTOR FEEDBACK J03 OP OM OP OM OPTO OUT TB0 OPTO OUT TB03 AC AC 5V / 0.5A RS3 TX RS3 RX GND BRAKE PS BRAKE PS TB03 3 CONTROL SUPPLY 50/60Hz 85-40V~ 0.5A MAX TB06 4 EXTERNAL SHUNT TB04 TM 5 ESTOP TB0 AEROTECH. COM 5 MOTOR SUPPLY MOTOR OUTPUT AUX I/O J04 40V~ MAX 50/60Hz 5A MAX AC AC A B C DANGER! High Voltage TB0 C GND C V NC C NO OPTO IN TB04 OPTO IN TB05 RELAY TB USB S/N - P/N - J0 Connect the Motor Outputs (TB0) and Motor Feedback (J03). Connect the PC to either the Ethernet (J0) or the USB (J0). Connect any additional I/O as required (not shown). Connect to the Control Supply (TB06). 5 Connect to the Motor Supply (TB0). Note: Connect to ESTOP (TB0) in this step if applicable. Figure : Quick Start Connections Topic Motor Output Motor Feedback Ethernet / USB Control Supply Motor Supply Additional I/O Section Section.. Motor Output Connections Section.3. Motor Feedback Connections (J03) No Section / Standard Connection Section... Control Supply Connections (TB06) Section... Motor Supply Connections (TB0) User / Application dependent 3

14 Quick Installation Guide This page intentionally left blank. 4

15 Introduction Chapter : Introduction Aerotech s (Compact PWM) network digital drive is a high performance amplifier. The drive provides deterministic behavior, auto-identification, and easy software setup. The s high performance double precision floating point DSP controls the digital PID and current loops. All system configuration is done using software-settable parameters, including control loop gains and system safety functions. The is offered with an optional encoder interpolation feature (-MXU), an auxiliary square wave encoder input for dual loop control, dedicated analog and digital I/O (expandable with the -IO option), and separate power connections for motor and control supply voltages. ENB/FLT MARKER ETHERNET J0 MOTOR FEEDBACK J03 PWR INPOS TB0 OP OM OP OM AGND AIN AIN- AOUT OPTO OUT TB0 OPTO OUT TB03 WARNING: DISCONNECT POWER BEFORE SERVICING HAZARDOUS VOLTAGES PRESENT UP TO 8 MIN. AFTER POWER IS DISCONNECTED AC AC 5V / 0.5A RS3 TX RS3 RX GND BRAKE PS BRAKE PS TB /60Hz 85-40V~ 0.5A MAX TB06 CONTROL SUPPLY EXTERNAL SHUNT TB04 TM ESTOP TB0 AEROTECH. COM AUX I/O J04 40V~ MAX 50/60Hz 5A MAX MOTOR SUPPLY MOTOR OUTPUT AC AC A B C DANGER! High Voltage TB0 C GND C V NC C NO OPTO IN TB04 OPTO IN TB05 RELAY TB06 USB J0 S/N - P/N - Standard Connector Description -IO/-IOH Board Option Connector Description J0 USB Port TB0 Analog I/O J0 Ethernet Port TB0 Opto-Outputs J03 Motor Feedback TB03 Opto-Outputs J04 Auxiliary I/O TB04 Opto-Inputs TB0 Motor Supply TB05 Opto-Inputs TB0 Motor Output TB06 Relay TB06 Control Supply Output TB0 Emergency Stop Sense Input (ESTOP) TB03 RS3/Brake Power Supply TB04 External Shunt Figure -: Networked Digital Drive Chapter 5

16 Introduction Table -: Standard Features Feature Summary Line driver square wave quadrature encoder input for position and velocity feedback Line driver square wave auxiliary quadrature encoder input or output for PSO Four opto-isolated user outputs Six opto-isolated user inputs (two high speed) One 6-bit differential analog input (± 0 V) One 6-bit analog output (±0 V) Dedicated 5-4 V Emergency Stop sense input VAC control supply inputs One fail-safe brake Single axis Position Synchronized Output (PSO) Absolute Encoder support Calibration (refer to the Soloist Help file for more information) Camming (refer to the Soloist Help file for more information) 0/00 BASE-T Ethernet port for use with Ethernet I/O modules Options -S Internal shunt resistor (standard on CP 30). 50 Ohm, 40 W Continuous; 400 W Peak (5 seconds), (Manufacturer's P/N: Ohmite F40J50RE or equivalent) -IO One 6-bit analog output (±0 V) One -bit differential analog input One fail-safe brake or user relay output -MXU -EXTSHUNT 6 optically isolated logic inputs (5-4 VDC), may be connected in current sourcing or sinking mode 6 optically isolated logic outputs (5-4 VDC), user defined as current sourcing or sinking Interpolation circuit allowing for analog sine wave input on the standard encoder channel. Interpolation factor: 4,096 Connection provided for an external shunt resistor network. Accessories UFM-ST AC Line Filter Module (required for CE compliance; refer to Section..) MCK-NDRIVE Mating connector kit for J03 (J04 mate is always provided) JI Industrial Joystick (NEMA (IP54) rated); refer to Section 4.. PS4-4 VDC, A power supply for optional brake/relay output BRAKE4-4 VDC, A power supply for optional brake Transformers Cables Interconnection Refer to Section..3. for listings, wiring, and specifications A complete list of Aerotech cables can be found on the website at Joystick/Handwheel Refer to Section 4.. or Section Chapter

17 Introduction The following block diagram shows a connection summary. For detailed connection information, refer to Chapter and Chapter 3. J0 J0 USB. Port Ethernet Port Analog Input /- Analog Output -IO Option TB0 J04 Aux I/O Encoder 5V / Common PSO Output, Encoder Echo SIN, COS, MRK (RS4) 4 Opto Outputs 4 Opto Inputs High Speed Opto Inputs Analog Input 0 /- Analog Output 0 6 Opto Outputs (Sinking or Sourcing) TB0 / TB03 Opto Out TB0 ESTOP J03 Motor Feedback Emergency Stop Sense Input -MXU Option SIN, COS, MRK (RS4) CW, CCW, Home Limits Encoder Fault Hall A, B, C Motor Over Temperature Brake ± Encoder 5V / Common 6 Opto Inputs Brake Power Input or Relay (jumper configurable) TB04 / TB05 Opto In TB06 Relay TB06 Control Supply AC AC AC AC Isolated Power Supply 5V / Common RS3 Brake Supply Input TB03 RS3 / Brake Supply TB04 -EXTSHUNT option TB0 Motor Supply AC AC AC AC Inrush Limiting Heatsink Over Temperature PWM Power Amplifier A B C A B C TB0 Motor Output Figure -: Functional Diagram Chapter 7

18 Introduction.. Drive and Software Compatibility The following table lists the available drives and which version of the software first supported the drive. Drives that list a specific version number in the Last Software Version column will not be supported after the listed version. Table -: Drive and Software Compatibility Drive Type Firmware Revision First Software Version Last Software Version CL A Current CP A.0 Current B.54 Current HLe -.5 Current HPe -.5 Current ML Current MP -.0 Current A.55 Current 8 Chapter

19 Introduction.. Electrical Specifications Table -3: Electrical Specifications Description CP 0 CP 0 CP 30 Input Voltage 4-40 VAC Input Frequency Hz Inrush Current 3 30 VAC; 6 5 VAC Motor Supply Maximum Continuous Input 5 A rms 0 A rms 0 A rms Current Input Current Refer to Section... System Power Requirements Input Voltage VAC Control Input Frequency Hz Supply Inrush Current 6 A Input Current.5 A max Output Voltage () VDC Peak Output Current ( second) 0 A 0 A 30 A Continuous Output Current 5 A 0 A 0 A Power Amplifier Bandwidth 500 Hz maximum (software selectable) Power Amplifier Efficiency 85% - 95% () PWM Switching Frequency Minimum Load Inductance User Power Supply Output Modes of Operation Protective Features Isolation () AC input voltage and load dependent. () Dependent on total output power: efficiency increases with increasing output power. 0 khz VDC ( 30 VDC) 5 VDC (@ 500 ma) Brushless; Brush; Stepper Output short circuit; Peak over current; DC bus over voltage; RMS over current; Over temperature; Control power supply under voltage; Power stage bias supply under voltage Optical and transformer isolation between control and power stages. Chapter 9

20 Introduction... System Power Requirements The following equations can be used to determine total system power requirements. The actual power required from the mains supply will be the combination of actual motor power (work), motor resistance losses, and efficiency losses in the power electronics or power transformer. An EfficiencyFactor of approximately 90% should be used in the following equations. Brushless Motor Output Power Rotary Motors Linear Motors Pout [W] = Torque [N m] * Angular velocity[rad/sec] Pout [W] = Force [N] * Linear velocity[m/sec] Rotary or Linear Motors Pout [W] = Bemf [V] * I(rms) * 3 Ploss = 3 * I(rms)^ * R(line-line)/ Pin = SUM ( Pout Ploss ) / EfficiencyFactor DC Brush Motor Pout [W] = Torque [N m] * Angular velocity[rad/sec] Ploss = I(rms)^ * R Pin = SUM ( Pout Ploss ) / EfficiencyFactor 0 Chapter

21 Introduction... Power Dissipation The amplifier power dissipation under continuous power supply and output current conditions is shown in Figure -3. The values on the graph represent the peak current that the amplifier would provide during operation. When the bus voltage and output current are known, the amplifier power dissipation is found using this graph. Figure -4 shows the maximum recommended ambient temperature as a function of amplifier power dissipation. Use this graph along with the power dissipation obtained from the first graph to determine the maximum ambient temperature. If the result is lower than the known operating ambient temperature, additional measures are required to cool the. Mounting it to a large metal plate for extra heatsinking and providing additional fan flow are suggested. 40 Power Dissipation (W) V Bus 60V Bus 80V Bus 40V Bus Figure -3: Output Current (A) Power Dissipation vs. Output Current Ambient Temperature (C) Absolute Maximum 0 Recommended Amplifier Dissipation (W) Figure -4: Ambient Temperature vs. Power Dissipation EXAMPLE: 30 VDC Bus operation at 5 A Power Dissipation = 47 Watts Maximum Ambient Temperature = 54 C Chapter

22 Introduction.3. Mechanical Design Install the unit into a construction compliant for unlimited circuits enclosure. Each unit should be separated from other drives and surrounded by 5 mm (") of free air space. A space of 00 mm (4") should be allowed along the front of the unit for cable connections [.59] 63.5 [.50] 3.8 [.5] 5.9 [0.63] (TYP.) Ø4.7 [Ø0.9] (TYP.) Ø0.3 [Ø0.4] (TYP.) ENB/FLT MARKER PWR INPOS TB0 AGND AIN AIN- AOUT ETHERNET J0 OP OM OPTO OUT TB0 MOTOR FEEDBACK J03 OP OM OPTO OUT TB [9.8] 8.6 [8.6] ESTOP TB0 TM AEROTECH. COM 98. [7.8] MOTOR SUPPLY MOTOR OUTPUT AUX I/O J04 40V~ MAX 50/60Hz 5A MAX AC AC A B C DANGER! High Voltage TB0 C GND C V NC C NO OPTO IN TB04 OPTO IN TB05 RELAY TB06 with I/O 630D059, REV H 9.8 [0.39] 4.7 [0.9] (TYP.) REC. MTG. HDWR: M4 [#8] 6. [0.64] 67.4 [6.59] 78. [7.0] 6.4 [0.5] Figure -5: Dimensions Table -4: Standard Physical Specifications Weight.63 kg (3.6 lb) Chapter

23 Introduction.4. Environmental Specifications The environmental specifications for the are listed below. Ambient Temperature Operating: 0 to 50 C (3 to F) Storage: -30 to 85 C (- to 85 F) Humidity Maximum relative humidity is 80% for temperatures up to 3 C. Decreasing linearly to 50% relative humidity at 40 C. Non condensing. Altitude Up to 000 meters. Pollution Pollution degree (normally only non-conductive pollution). Use Indoor use only. Chapter 3

24 Introduction This page intentionally left blank. 4 Chapter

25 Installation and Configuration Chapter : Installation and Configuration.. Power Connections The has two AC input connectors; one for control power and a second for motor power. For a complete list of electrical specifications, refer to Section.. N O T E : The machine integrator, OEM or end user is responsible for meeting the final protective grounding requirements of the system. Chapter 5

26 Installation and Configuration... Control Supply Connections (TB06) N O T E : This product requires two power supply connections. The Motor Supply and Control Supply must both be connected for proper operation. The control power supply input allows the to maintain communications if the motor power is removed, such as in an Emergency Stop condition. The control power supply requires a minimum of 85 VAC input to operate properly. The AC input is internally fused. The AC input is not internally fused but can be connected to a voltage source other than Neutral if an external A time-delay fuse is used. Although the control power supply contains an internal filter, an additional external filter located as close as possible to the may be required for CE compliance (Aerotech recommends Schaffner FN080 or Aerotech UFM-ST). Line (L) Neutral (N) Ground Line Filter AC AC 3 50/60Hz 85-40V~ 0.5A MAX TB06 CONTROL SUPPLY Figure -: Control Supply Connections Table -: Control Supply AC Input Wiring Recommended Wire Pin Description Size AC Line (L): VAC Control Power Input 0.8 mm (#8 AWG) AC Neutral (0V) or VAC Control Power Input with external fuse 0.8 mm (#8 AWG) Table -: Protective Ground (Required for Safety) Control Supply Mating Connector 0.8 mm (#8 AWG) Screw Torque Wire Size: Type Aerotech P/N Phoenix P/N Value: Nm AWG [mm ] 3-Pin Terminal Block ECK [ ] 6 Chapter

27 Installation and Configuration... Motor Supply Connections (TB0) N O T E : This product requires two power supply connections. The Motor Supply and Control Supply must both be connected for proper operation. Motor power is applied to the Motor Supply connector (refer to Figure - for locations). Wires must be properly matched to the fuses or circuit breakers and must be sized to meet local electrical safety codes. The AC input is internally fused (5A CP0, 0A CP0/30). External fuses or a circuit breaker (5 A maximum, time delay type) are required for the AC and AC inputs. The AC input can be connected directly to Neutral without a fuse for single phase power systems. W A R N I N G : Do not operate the without the safety ground connection in place. W A R N I N G : Do not operate the without proper branch protection. An AC Line Filter may be required for CE compliance and should be located as close as possible to the drive. For more information about the AC Line Filter, refer to Section..4. Wiring between the filter and drive can be twisted and/or shielded to reduce radiated emissions. Line (L) Neutral (N) Ground Line Filter MOTOR SUPPLY MOTOR OUTPUT AC AC A B C Figure -: Motor Bus Input Connections TB0 Table -3: Motor Supply Mating Connector Tightening Wire Size: Description Aerotech P/N Phoenix P/N Torque (Nm) AWG [mm ] 7-Pin Terminal Block ECK [-30]. Recommended Wire Size:.3 mm (#6 AWG) Chapter 7

28 Installation and Configuration..3. Transformer Options An external isolation transformer can be connected to the motor supply AC input. This is done to reduce the operating voltage of the motor and may also reduce electrical noise. Table -4: Nominal Motor Operating Voltages / Required AC Voltages AC Voltage DC Voltage Table -5: Transformer TV ST TM3 TM5 TV0.3-8 TV Transformer Options Description Generate 8 or 56 VAC from 5 VAC or 30 VAC input source voltage. When rectified by the drive, it produces a 40 or 80 VDC power bus. Power up to 4 drives, providing 300 watts of power Power up to 4 drives providing 500 watts of power Generate 8 VAC from 5 VAC or 30 VAC input source voltage. When rectified by the drive, it produces a 40 VDC power bus. Generate 56 VAC from 5 VAC or 30 VAC input source voltage. When rectified by the drive, it produces an 80 VDC power bus. TV.5, TV.5, or TV5.5 kva,.5 kva, or 5 kva isolation transformer; 5/30 VAC input; 8, 43, 56, 70, 5 VAC output Figure -3: Transformer Examples 8 Chapter

29 Installation and Configuration Drive Motor Supply AC AC Internal Thermal Switch 8V 0V 8V Integral Fuse 3.5A Slow-Blow F-OUT 5V 00V 0V 5V 00V F-IN 4 AC HI AC LO SAFETY 5 VAC 50/60 HZ INPUT 0V 0V Frame Ground Control Supply AC AC 6 TV ST Wiring 5 VAC INPUT Secondary = 8 VAC (40 VDC Bus) Drive Motor Supply AC AC Internal Thermal Switch 8V 0V 8V Integral Fuse 3.5A Slow-Blow F-OUT 5V 00V 0V 5V 00V F-IN 4 AC HI AC LO SAFETY 30 VAC 50/60 HZ INPUT 0V 0V Frame Ground Control Supply AC AC 6 HAZARDOUS VOLTAGES PRESENT TV ST Wiring 30 VAC INPUT CONNECT ALL WIRING BEFORE POWERING TRANSFORMER Secondary = 8 VAC (40 VDC Bus) FOLLOW ALL APPLICABLE WIRING AND SAFETY CODES.. For 00 VAC primary input, parallel the 00 VAC taps and leave the 5 VAC taps unterminated.. For 00 VAC primary input, series the 00 VAC taps and leave the 5 VAC taps unterminated. 3. When using an isolation transformer, earth grounding of the AC input tap reduces electrical and audible noise emissions and provides increased servo performance. 4. Transformer Primary Wiring: 0.8 mm (#8 AWG) 300 V wire. 5. Transformer Secondary Wiring:.3 mm (#6 AWG) 300 V wire. 6. AC line filters are for CE compliance. Filters may also be located on the primary side of the transformer. Drawing: 60B346-8, Rev. - Figure -4: 40 VDC Motor Power with a TV ST Transformer Chapter 9

30 Installation and Configuration Drive AC 5 Internal Thermal Switch 8V Integral Fuse 3.5A Slow-Blow 5V F-IN F-OUT AC HI AC LO SAFETY 5 VAC 50/60 HZ INPUT Motor Supply AC 3 6 0V 8V 00V 0V 5V 00V 4 0V 0V Frame Ground Control Supply AC AC 6 TV ST Wiring 5 VAC INPUT Secondary = 88 = 56 VAC (80 VDC Bus) Drive AC 5 Internal Thermal Switch 8V Integral Fuse 3.5A Slow-Blow 5V F-IN F-OUT AC HI AC LO SAFETY 30 VAC 50/60 HZ INPUT Motor Supply AC 3 6 0V 8V 00V 0V 5V 00V 4 0V 0V Frame Ground Control Supply AC AC 6 HAZARDOUS VOLTAGES PRESENT TV ST Wiring 30 VAC INPUT CONNECT ALL WIRING BEFORE POWERING TRANSFORMER Secondary = 88 = 56 VAC (80 VDC Bus) FOLLOW ALL APPLICABLE WIRING AND SAFETY CODES.. For 00 VAC primary input, parallel the 00 VAC taps and leave the 5 VAC taps unterminated.. For 00 VAC primary input, series the 00 VAC taps and leave the 5 VAC taps unterminated. 3. When using an isolation transformer, earth grounding of the AC input tap reduces electrical and audible noise emissions and provides increased servo performance. 4. Transformer Primary Wiring: 0.8 mm (#8 AWG) 300 V wire. 5. Transformer Secondary Wiring:.3 mm (#6 AWG) 300 V wire. 6. AC line filters are for CE compliance. Filters may also be located on the primary side of the transformer. Drawing: 60B346-9, Rev. - Figure -5: 80 VDC Motor Power with a TV ST Transformer 30 Chapter

31 Installation and Configuration Drive AC 7 8V RED Internal Thermal Switch #8 WHT #8 WHT 5V BLK Primary Fuse 4A Slow-Blow splice 4 AC HI AC LO SAFETY 5 VAC 50/60 HZ INPUT Motor Supply AC 3 5 0V GRN 8V YEL 00V ORN 0V GRY 5V BRN 00V GRN 6 0V BLK 0V BLU splice Frame Ground Control Supply AC AC 5 TV0.3-8 Wiring 5 VAC INPUT Secondary = 8 VAC (40 VDC Bus) Drive AC 7 8V RED Internal Thermal Switch #8 WHT #8 WHT 5V BLK Primary Fuse 4A Slow-Blow splice 4 AC HI AC LO SAFETY 30 VAC 50/60 HZ INPUT Motor Supply AC 3 5 0V GRN 8V YEL 00V ORN 0V GRY 5V BRN 00V GRN splice 6 0V BLK 0V BLU Frame Ground Control Supply AC AC 5 HAZARDOUS VOLTAGES PRESENT TV0.3-8 Wiring 30 VAC INPUT CONNECT ALL WIRING BEFORE POWERING TRANSFORMER Secondary = 8 VAC (40 VDC Bus) FOLLOW ALL APPLICABLE WIRING AND SAFETY CODES.. For 00 VAC primary input, parallel the 00 VAC taps and leave the 5 VAC taps unterminated.. For 00 VAC primary input, series the 00 VAC taps and leave the 5 VAC taps unterminated. 3. When using an isolation transformer, earth grounding of the AC input tap reduces electrical and audible noise emissions and provides increased servo performance. 4. Additional or alternative fusing may be required for optimum protection 5. AC line filters are required for CE compliance. Filters may also be located on the primary side of the transformer. 6. Transformer Primary Wiring: 0.8 mm (#8 AWG) 300 V wire. 7. Transformer Secondary Wiring:.3 mm (#6 AWG) 300 V wire. Drawing: 60B346- Figure -6: 40 Volt DC Bus from 5 and 30 VAC Source Chapter 3

32 Installation and Configuration Drive AC 7 56V RED Internal Thermal Switch #8 WHT #8 WHT 5V BLK Primary Fuse 4A Slow-Blow splice 4 AC HI AC LO SAFETY 5 VAC 50/60 HZ INPUT Motor Supply AC 3 5 0V GRN 56V YEL 00V ORN 0V GRY 5V BRN 00V GRN 6 0V BLK 0V BLU splice Frame Ground Control Supply AC AC 5 TV Wiring 5 VAC INPUT Secondary = 56 VAC (80 VDC Bus) Drive AC 7 56V RED Internal Thermal Switch #8 WHT #8 WHT 5V BLK Primary Fuse 4A Slow-Blow splice 4 AC HI AC LO SAFETY 30 VAC 50/60 HZ INPUT Motor Supply AC 3 5 0V GRN 56V YEL 00V ORN 0V GRY 5V BRN 00V GRN splice 6 0V BLK 0V BLU Frame Ground Control Supply AC AC 5 HAZARDOUS VOLTAGES PRESENT TV Wiring 30 VAC INPUT CONNECT ALL WIRING BEFORE POWERING TRANSFORMER Secondary = 56 VAC (80 VDC Bus) FOLLOW ALL APPLICABLE WIRING AND SAFETY CODES. For 00 VAC primary input, parallel the 00 VAC taps and leave the 5 VAC taps unterminated.. For 00 VAC primary input, series the 00 VAC taps and leave the 5 VAC taps unterminated. 3. When using an isolation transformer, earth grounding of the AC input tap reduces electrical and audible noise emissions and provides increased servo performance. 4. Additional or alternative fusing may be required for optimum protection 5. AC line filters are required for CE compliance. Filters may also be located on the primary side of the transformer. 6. Transformer Primary Wiring: 0.8 mm (#8 AWG) 300 V wire. 7. Transformer Secondary Wiring:.3 mm (#6 AWG) 300 V wire. Figure -7: 80 Volt DC Bus from 5 and 30 VAC Source (TV0.3-56) 3 Chapter

33 Installation and Configuration Drive AC 7 56V RED Internal Thermal Switch #8 WHT #8 WHT 5V BLK Primary Fuse 4A Slow-Blow splice 4 AC HI AC LO SAFETY 5 VAC 50/60 HZ INPUT Motor Supply AC 3 5 0V GRN splice 56V YEL 00V ORN 0V GRY 5V BRN 00V GRN 6 0V BLK 0V BLU splice Frame Ground Control Supply AC AC 5 TV ST Wiring 5 VAC INPUT Secondary = 5 VAC (60 VDC Bus) Drive AC 7 56V RED Internal Thermal Switch #8 WHT #8 WHT 5V BLK Primary Fuse 4A Slow-Blow splice 4 AC HI AC LO SAFETY 30 VAC 50/60 HZ INPUT Motor Supply AC 3 5 0V GRN splice 56V YEL 00V ORN 0V GRY 5V BRN 00V GRN splice 6 0V BLK 0V BLU Frame Ground Control Supply AC AC 5 HAZARDOUS VOLTAGES PRESENT TV ST Wiring 30 VAC INPUT CONNECT ALL WIRING BEFORE POWERING TRANSFORMER Secondary = 5 VAC (60 VDC Bus) FOLLOW ALL APPLICABLE WIRING AND SAFETY CODES. For 00 VAC primary input, parallel the 00 VAC taps and leave the 5 VAC taps unterminated.. For 00 VAC primary input, series the 00 VAC taps and leave the 5 VAC taps unterminated. 3. When using an isolation transformer, earth grounding of the AC input tap reduces electrical and audible noise emissions and provides increased servo performance. 4. Additional or alternative fusing may be required for optimum protection 5. AC line filters are for CE compliance. Filters may also be located on the primary side of the transformer. 6. Transformer Primary Wiring: 0.8 mm (#8 AWG) 300 V wire. 7. Transformer Secondary Wiring:.3 mm (#6 AWG) 300 V wire. Drawing: 60B346-3 Figure -8: 60 Volt DC Bus from 5 and 30 VAC Source (TV0.3-56) Chapter 33

34 Installation and Configuration ST CP TM3/TM5 TRANSFORMER MODULE AC AC MOTOR SUPPLY MOTOR OUTPUT AC AC 3 A B C TB0 CONTROL SUPPLY 50/60Hz 85-40V~ 0.5A MAX TB06 TB MAIN SUPPLY CONTROL SUPPLY TB 8~ 0~ L 5~ N 8~ 0~ L 5~ N TB3 MAIN SUPPLY CONTROL SUPPLY TB4 AC AC AC AC 3rd CP MOTOR SUPPLY TB0 CONTROL SUPPLY TB06 MOTOR SUPPLY TB0 AC AC MAIN SUPPLY 8~ 0~ 8~ 0~ MAIN SUPPLY AC AC MOTOR SUPPLY TB0 CONTROL SUPPLY TB06 AC AC nd CP CONTROL SUPPLY L 5~ N L 5~ N CONTROL SUPPLY AC AC 4th CP CONTROL SUPPLY TB06 4VDC A MAX Use to power User-Supplied ESTOP circuitry Transformer Module AEROTECH.COM DANGER! High Voltage ON O OFF HAZARDOUS VOLTAGES PRESENT CONNECT ALL WIRING BEFORE POWERING TRANSFORMER FOLLOW ALL APPLICABLE WIRING AND SAFETY CODES.. See the TM3 or TM5 manual for input voltage configuration. Wiring Specifications:.3 mm (#6 AWG) 300 V wire. 3. Control Supply output voltage (5 VAC in this example) is always the same as the AC Input Voltage to the unit. Figure -9: Control and Motor Power Wiring using a TM3 or TM5 Transformer 34 Chapter

35 Installation and Configuration..4. Minimizing Conducted, Radiated, and System Noise The generates conducted (AC line) and radiated noise. Conducted emissions are minimized by using line filters and should be located as close to the drive as possible for maximum effectiveness. User connections to the product must be made using shielded cables with metal D-style connectors and back shells. The shield of the cables must be connected to the metal back shell in order for the product to conform to radiated emission standards.the is a component designed to be integrated with other electronics. EMC testing must be conducted on the final product configuration. Ferrite beads can be used on the motor leads to reduce the effects of PWM noise. Table -6: Ferrite Noise Suppression Numbers Wire Size Aerotech P/N Third Party P/N 3.3 mm (#6 AWG) N/A # Elna Fair-Rite Products 8.3 mm (#8 AWG) ECZ0085 # Elna Fair-Rite Products.0 mm (#4 AWG) EIZ007 # Elna Fair-Rite Products.3 mm (#6 AWG) EIZ005 # Elna Fair-Rite Products 0.8 mm (#8 AWG) EIZ000 # Elna Fair-Rite Products 0.5 mm (#0 AWG) EIZ000 # Elna Fair-Rite Products Aerotech's UFM-ST AC line filter and isolation transformers connected to the motor supply AC input are also effective in reducing PWM generated noise and improving performance (refer to Section..3.). Table -7: UFM-ST Electrical Specifications Specification Input Voltage Range Output Voltage Range Maximum Continuous Current Frequency Phases Leakage Current Fuse Protection Value 0-40 VAC 0-40 VAC 8 A rms with convection cooling 0 A rms with forced air cooling 50/60 Hz Single Phase. ma (max) Internal 0 A fuses on AC and AC inputs AC AC TB- TB- F 0 ASB 3AG F 0 ASB 3AG JP4 JP3 LINE INTERNAL FILTER COMPONENTS LOAD TB- TB- AC AC TO MAINS GND TB-3 QVR V0E385P QVR V0E385P TO DRIVE TB-3 GND Figure -0: AC Line Filter (UFM-ST) Chapter 35

36 Installation and Configuration.. Motor Output Connections The is capable of controlling three motor types: Brushless (see Section...) DC Brush (see Section...) Stepper (see Section..3.) For a complete list of electrical specifications, refer to Section.. Table -8: Motor Power Output Connections (TB0) Pin Description Recommended Wire Size ØA Phase A Motor Lead.3 mm (#6 AWG) ØB Phase B Motor Lead.3 mm (#6 AWG) ØC Phase C Motor Lead.3 mm (#6 AWG) Earth Ground to Motor (required for safety).3 mm (#6 AWG) Table -9: Motor Power Output Mating Connector Tightening Wire Size: Description Aerotech P/N Phoenix P/N Torque (Nm) AWG [mm ] 7-Pin Terminal Block ECK [-30]. Recommended Wire Size:.3 mm (#6 AWG) 36 Chapter

37 Installation and Configuration... Brushless Motor Connections The configuration shown in Figure - is an example of a typical brushless motor connection. MOTOR SUPPLY MOTOR OUTPUT AC AC A B C TB0 Install Aerotech FBF-3 or FBF-4 or 0 beads per wire at drive (Elna Fair-Rite # or # ). Green/Yellow & Shield Black Red White Motor Frame AC Brushless Motor NOTE: Listed wire colors are for Aerotech supplied cables. Figure -: Brushless Motor Configuration Table -0: Wire Colors for Aerotech Supplied Cables (Brushless) Pin Wire Color Set () Wire Color Set Wire Color Set 3 Wire Color Set 4 Green/Yellow & Shield () Green/Yellow & Shield Green/Yellow & Shield Green/Yellow & Shield A Black Blue & Yellow Black # Black & Brown B Red Red & Orange Black # Red & Orange C White White & Brown Black #3 Violet & Blue () Wire Color Set # is the typical Aerotech wire set used by Aerotech. () & (Red & Orange) indicates two wires; / (Green/White) indicates a single wire N O T E : Brushless motors are commutated electronically by the controller. The use of Hall effect devices for commutation is recommended. The controller requires that the Back-EMF of each motor phase be aligned with the corresponding Hall-effect signal. To ensure proper alignment, motor, Hall, and encoder connections should be verified using one of the following methods: powered, through the use of a test program; or unpowered using an oscilloscope. Both methods will identify the A, B, and C Hall/motor lead sets and indicate the correct connections to the controller. Refer to Section... for powered motor phasing or Section... for unpowered motor and feedback phasing. N O T E : If using standard Aerotech motors and cables, motor and encoder connection adjustments are not required. Chapter 37

38 Installation and Configuration... Powered Motor Phasing Refer to the Motor Phasing Calculator in the Configuration Manager for motor, Hall, and encoder phasing. Feedback Monitoring The state of the encoder and Hall-effect device signals can be observed in the Motion Composer. A 0 for the given Hall input indicates zero voltage or logic low, where a indicates 5V or logic high. Figure -: Encoder and Hall Signal Diagnostics 38 Chapter

39 Installation and Configuration... Unpowered Motor and Feedback Phasing Disconnect the motor from the controller and connect the motor in the test configuration shown in Figure - 3. This method will require a two-channel oscilloscope, a 5V power supply, and six resistors (0,000 ohm, /4 watt). All measurements should be made with the probe common of each channel of the oscilloscope connected to a neutral reference test point (TP4, shown in Figure -3). Wave forms are shown while moving the motor in the positive direction. CHANNEL CHANNEL Figure -3: TP TP TP3 TP4 Power Supply COM 5V TP5 TP6 TP7 0K OHM TYP "Wye" Configuration 0K OHM TYP Motor Lead = ØB Motor Lead = ØC Motor Lead 3 = ØA COM 5V Hall Hall Hall 3 Motor Phasing Oscilloscope Example With the designations of the motor and Hall leads of a third party motor determined, the motor can now be connected to an Aerotech system. Connect motor lead A to motor connector A, motor lead B to motor connector B, and motor lead C to motor connector C. Hall leads should also be connected to their respective feedback connector pins (Hall A lead to the Hall A feedback pin, Hall B to Hall B, and Hall C to Hall C). The motor is correctly phased when the Hall states align with the Back EMF as shown in (Figure -4). Use the CommutationOffset parameter to correct for Hall signal misalignment Hall A Hall B 5V 0V Hall C ØC ØB ØA ØC ØB V Motor Back EMF 0V -V Figure -4: Brushless Motor Phasing Goal Chapter 39

40 Installation and Configuration... DC Brush Motor Connections The configuration shown in Figure -5 is an example of a typical DC brush motor connection. Refer to Section... for information on motor phasing. MOTOR SUPPLY MOTOR OUTPUT AC AC A B C TB0 no connection Figure -5: Install Aerotech FBF-5 or FBF-6 or 0 beads per wire at drive (Elna Fair-Rite # or # ). Green & White & Shield Red & Orange Yellow & Blue Motor Frame DC Brush - Motor NOTE: Listed wire colors are for Aerotech supplied cables. DC Brush Motor Configuration Table -: Wire Colors for Aerotech Supplied Cables (DC Brush) Pin Wire Color Set () Wire Color Set Wire Color Set 3 Green & White & Shield () Green/Yellow & Shield Green/Yellow & Shield A Red & Orange Red Red & Orange C Yellow & Blue Black Yellow & Blue () Wire Color Set # is the typical Aerotech wire set used by Aerotech. () & (Red & Orange) indicates two wires; / (Green/White) indicates a single wire 40 Chapter

41 Installation and Configuration... DC Brush Motor Phasing A properly phased motor means that the positive motor lead should be connected to the ØA motor terminal and the negative motor lead should be connected to the ØC motor terminal. To determine if the motor is properly phased, connect a voltmeter to the motor leads of an un-powered motor:. Connect the positive lead of the voltmeter to the one of the motor terminals.. Connect the negative lead of the voltmeter to the other motor terminal. 3. Rotate the motor clockwise by hand. ROTARY MOTOR Motor Mounting Flange (Front View) Motor Shaft Figure -6: POSITIVE MOTION Clockwise Motor Rotation 4. If the voltmeter indicates a negative value, swap the motor leads and rotate the motor (CW, by hand) again. When the voltmeter indicates a positive value, the motor leads have been identified. 5. Connect the motor lead from the voltmeter to the ØA motor terminal on the. Connect the motor lead from the negative lead of the voltmeter to the ØC motor terminal on the. N O T E : If using standard Aerotech motors and cables, motor and encoder connection adjustments are not required. Chapter 4

42 Installation and Configuration..3. Stepper Motor Connections The configuration shown in Figure -7 is an example of a typical stepper motor connection. Refer to Section..3.. for information on motor phasing. In this case, the effective motor voltage is half of the applied bus voltage. For example, an 80V motor bus supply is needed to get 40V across the motor. MOTOR SUPPLY MOTOR OUTPUT AC AC A B C TB0 Install Aerotech FBF-3 or FBF-4 or 0 beads per wire at drive (Elna Fair-Rite # or # ). Green/Yellow & Shield Black Red White NOTE: Listed wire colors are for Aerotech supplied cables. Motor Frame B B' A Stepper Motor A' Figure -7: Stepper Motor Configuration Note the common connection of A and B phases. Table -: Wire Colors for Aerotech Supplied Cables (Stepper) Pin Wire Color Set () Wire Color Set Green/Yellow & Shield () Green/Yellow & Shield A Black Brown B Red Yellow C White White & Red () Wire Color Set # is the typical Aerotech wire set used by Aerotech. () & (Red & Orange) indicates two wires; / (Green/White) indicates a single wire 4 Chapter

43 Installation and Configuration..3.. Stepper Motor Phasing A stepper motor can be run with or without an encoder. If an encoder is not being used, phasing is not necessary. With an encoder, test for proper motor phasing by running a positive motion command. If there is a positive scaling factor (determined by the CountsPerUnit parameters) and the motor moves in a clockwise direction, as viewed looking at the motor from the front mounting flange, the motor is phased correctly. If the motor moves in a counterclockwise direction, swap the motor leads and re-run the command. Proper motor phasing is important because the end of travel (EOT) limit inputs are relative to motor rotation. ROTARY MOTOR Motor Mounting Flange (Front View) Motor Shaft Figure -8: POSITIVE MOTION Clockwise Motor Rotation N O T E : If using standard Aerotech motors and cables, motor and encoder connection adjustments are not required. N O T E : After the motor has been phased, use the ReverseMotionDirection parameter to change the direction of positive motion. Chapter 43

44 Installation and Configuration.3. Motor Feedback Connections (J03) The motor feedback connector (a 5-pin, D-style connector) has inputs for an encoder, limit switches, Halleffect devices, motor over-temperature device, 5 Volt encoder and limit power, and optional brake connection. The connector pin assignment is shown below with detailed connection information in the following sections. Table -3: Motor Feedback Connector Pin Assignment (J03) Pin# Description In/Out/Bi Connector Chassis Frame Ground N/A Motor Over Temperature Thermistor Input 3 5V Power for Encoder (500 ma max) Output 4 Reserved N/A 5 Hall-Effect Sensor B (brushless motors only) Input 6 Encoder Marker Reference Pulse - Input Absolute Encoder Interface Clock - Output 7 Encoder Marker Reference Pulse Input Absolute Encoder Interface Clock Output 8 Absolute Encoder Interface Data - Bidirectional 9 Reserved N/A 0 Hall-Effect Sensor A (brushless motors only) Input Hall-Effect Sensor C (brushless motors only) Input Clockwise End of Travel Limit Input 3 Optional Brake - Output Output 4 Encoder Cosine Input 5 Encoder Cosine - Input 6 5V Power for Limit Switches (500 ma max) Output 7 Encoder Sine Input 8 Encoder Sine - Input 9 Absolute Encoder Interface Data Bidirectional 0 Signal Common for Limit Switches N/A Signal Common for Encoder N/A Home Switch Input Input 3 Encoder Fault Input Input 4 Counterclockwise End of Travel Limit Input 5 Optional Brake Output Output 3 5 Mating Connector Aerotech P/N Third Party P/N 5-Pin D-Connector ECK000 FCI DB5P064TXLF Backshell ECK00656 Amphenol 7E Chapter

45 Installation and Configuration.3.. Encoder Interface (J03) The is equipped with standard and auxiliary encoder feedback channels. The standard encoder interface is accessible through the Motor Feedback (J03) connector. The standard encoder interface will accept an RS-4 differential line driver signal. If the has been purchased with the -MXU option, the standard encoder interface can be configured for an analog encoder input via parameter settings. Refer to Section for encoder feedback phasing. Refer to Section.5. for the auxiliary encoder channel. N O T E : Encoder wiring should be physically isolated from motor, AC power, and all other power wiring. N OT E : The PSO feature is not compatible with the -MXU option. The PSO feature operates with the - MXH option and with square wave encoders. Table -4: Encoder Interface Pin Assignment Pin# Description In/Out/Bi Chassis Frame Ground N/A 3 5V Power for Encoder (500 ma max) Output 6 Encoder Marker Reference Pulse - Input Absolute Encoder Interface Clock - Output 7 Encoder Marker Reference Pulse Input Absolute Encoder Interface Clock Output 4 Encoder Cosine Input 5 Encoder Cosine - Input 7 Encoder Sine Input 8 Encoder Sine - Input Signal Common for Encoder N/A Chapter 45

46 Installation and Configuration.3... RS-4 Line Driver Encoder (Standard) The standard encoder interface accepts an RS-4 differential quadrature line driver signal. Invalid or missing signals will cause a feedback fault when the axis is enabled. An analog encoder is used with the -MXU option (refer to Section for more information). Table -5: Encoder Specifications Specification Encoder Frequency x4 Quadrature Decoding Value 0 MHz maximum (5 nsec minimum edge separation) 40 million counts/sec 3.3V 3.3V 0K 0K 0K 0K J03-7 J03-8 J03-4 J DS6LV3AT 0K 0 ADG80 0 0K 0K 0K 5V ENCODER FAULT DETECTION J03-6 J03-7 SIN SIN- COS COS- MRK- MRK ADM485 Figure -9: Line Driver Encoder Interface (J03) 46 Chapter

47 Installation and Configuration.3... EnDat Encoder Interface (J03) The retrieves absolute position data along with encoder fault information via a serial data stream from the absolute encoder. See Figure -0 for the serial data stream interface. Set up of this interface requires setting parameters EnDatEncoderResolution, EnDatEncoderSetup, and EnDatEncoderTurns. The encoder interface pin assignment is indicated in Section.3.. N OT E : The PSO feature is not compatible with the -MXU option. The PSO feature operates with the - MXH option and with square wave encoders. 5V ABS CLK- J03-6 ABS CLK J03-7 ADM485 ABS DATA- J03-8 ABS DATA J03-9 Figure -0: 80 Serial Data Stream Interface ADM485 Chapter 47

48 Installation and Configuration Resolute Encoder Interface (J03) The retrieves absolute position data along with encoder fault information via a serial data stream from the resolute encoder. See Figure - for the serial data stream interface. Set up of this interface requires setting parameters ResoluteEncoderResolution, ResoluteEncoderSetup, and ResoluteEncoderUserResolution. The encoder interface pin assignment is indicated in Section.3.. 5V ABS CLK- J03-6 ABS CLK J03-7 ADM485 ABS DATA- J03-8 ABS DATA J03-9 Figure -: 80 Serial Data Stream Interface ADM Chapter

49 Installation and Configuration Analog Encoder Interface If the -MXU option has been purchased, the standard encoder channel will accept a differential analog encoder input signal. The interpolation factor is determined by the EncoderMultiplicationFactor parameter and is software selectable (refer to the Soloist Help file). Table -6: Specification Input Frequency (max) Input Amplitude Analog Encoder Specifications Interpolation Factor (software selectable) Value 00 khz 0.6 to.5 Vpk-Vpk 4,096 Refer to Figure - for the typical input circuitry. The encoder interface pin assignment is indicated in Section.3.. The gain, offset, and phase balance of the analog Sine and Cosine encoder input signals can all be adjusted via controller parameters. Encoder signals should be adjusted using the Feedback Tuning tab of the Digital Scope, which will automatically adjust the encoder parameters for optimum performance. See the Soloist Help file for more information. SIN LINEAR MOTOR Forcer Wires Positive MOVE (Clockwise) SIN-N Magnet Track Forcer COS Vpk-pk COS-N ROTARY MOTOR MRK Motor Shaft MRK-N Positive MOVE (Clockwise) Figure -: CW Rotation (Positive Direction) Analog Encoder Phasing Reference Diagram Motor Mounting Flange (Front View) N O T E : The input amplitude is measured peak to peak for any encoder signal (sin, sin-n, cos, cos-n) relative to signal common. These signals have a typical offset voltage of V to.5v. Chapter 49

50 Installation and Configuration J03-7 SIN K 8PF K 8PF K J03-8 SIN- K 8PF 8PF K - AD UF 6.3V J03-4 COS K A 8PF K 8PF K J03-5 COS- K 8PF 8PF K - AD UF 6.3V J03-7 MRK K A 8PF K 8PF K J03-6 MRK- K 8PF 8PF K - AD UF 6.3V A Figure -3: Analog Encoder Interface (J03) 50 Chapter

51 Installation and Configuration Encoder Phasing Incorrect encoder polarity will cause the system to fault when enabled or when a move command is issued. Figure -4 illustrates the proper encoder phasing for clockwise motor rotation (or positive forcer movement for linear motors). To verify, move the motor by hand in the CW (positive) direction while observing the position of the encoder in the diagnostics display (see Figure -5). The Motor Phasing Calculator in the Configuration Manager can be used to determine proper encoder polarity. For dual loop systems, the velocity feedback encoder is displayed in the diagnostic display (Figure -5) SIN LINEAR MOTOR Forcer Wires Positive MOVE (Clockwise) SIN-N Magnet Track Forcer COS Vpk-pk COS-N ROTARY MOTOR MRK MRK-N Positive MOVE (Clockwise) Figure -4: Motor Shaft CW Rotation (Positive Direction) Encoder Phasing Reference Diagram (Standard) Motor Mounting Flange (Front View) N O T E : Encoder manufacturers may refer to the encoder signals as A, B, and Z. The proper phase relationship between signals is shown in Figure Chapter 5

52 Installation and Configuration Figure -5: Position Feedback in the Diagnostic Display 5 Chapter

53 Installation and Configuration.3.. Hall-Effect Interface (J03) The Hall-effect switch inputs are recommended for AC brushless motor commutation but not absolutely required. The Hall-effect inputs accept 5-4 VDC level signals. Hall states (0,0,0) or (,,) are invalid and will generate a "Hall Fault" axis fault. Refer to Section... for Hall-effect device phasing. Table -7: Hall-Effect Feedback Interface Pin Assignment (J03) Pin# Description In/Out/Bi Chassis Frame Ground N/A 3 5V Power for Encoder (500 ma max) Output 5 Hall-Effect Sensor B (brushless motors only) Input 0 Hall-Effect Sensor A (brushless motors only) Input Hall-Effect Sensor C (brushless motors only) Input Signal Common for Encoder N/A 5V 0K 0K 0K J03-0 J03-5 J03- HALL A HALL B HALL C 0K 0K 0K UF.0UF.0UF Figure -6: Hall-Effect Inputs (J03) Chapter 53

54 Installation and Configuration.3.3. Thermistor Interface (J03) The thermistor input is used to detect a motor over temperature condition by using a positive temperature coefficient sensor. As the temperature of the sensor increases, so does the resistance. Under normal operating conditions, the resistance of the thermistor is low (i.e., 00 ohms) which will result in a low input signal. As the increasing temperature causes the thermistor s resistance to increase, the signal will be seen as a logic high triggering an over temperature fault. The nominal trip value of the sensor is k Ohm. Table -8: Thermistor Interface Pin Assignment (J03) Pin# Description In/Out/Bi Motor Over Temperature Thermistor Input 5V K J03- THERMISTOR.00 0K.0UF Figure -7: Thermistor Interface Input (J03) 54 Chapter

55 Installation and Configuration.3.4. Encoder Fault Interface (J03) The encoder fault input is for use with encoders that have a fault output. This is provided by some manufactures and indicates a loss of encoder function. The active state of this input is parameter configurable and the controller should be configured to disable the axis when the fault level is active. Table -9: Encoder Fault Interface Pin Assignment (J03) Pin# Description In/Out/Bi 3 Encoder Fault Input Input 5V K J03-3 ENCODER FAULT 0K.0UF.00 Figure -8: Encoder Fault Interface Input (J03) Chapter 55

56 Installation and Configuration.3.5. End Of Travel Limit Input Interface (J03) End of Travel (EOT) limits are used to define the end of physical travel. The EOT limit inputs accept 5-4 VDC level signals. The active state of the EOT limits is software selectable by the EndOfTravelLimitSetup axis parameter (refer to the Soloist Help file). Limit directions are relative to the encoder polarity in the diagnostics display (refer to Figure -3). Positive motion is stopped by the clockwise (CW) end of travel limit input. Negative motion is stopped by the counterclockwise (CCW) end of travel limit input. The Home Limit switch can be parameter configured for use during the home cycle, however, the CW or CCW EOT limit is typically used instead. Opto-isolated user inputs 0-3 can also be used as the end-of-travel limit inputs, see Section V Limit Com 6 0 Normally closed shown (typical). MOTOR FEEDBACK J03 CW CCW 4 4 Home May be a separate switch. Figure -9: End of Travel Limit Input Connections Table -0: End of Travel Limit Input Interface Pin Assignment (J03) Pin# Description In/Out/Bi Clockwise End of Travel Limit Input 6 5V Power for Limit Switches (500 ma max) Output 0 Signal Common for Limit Switches N/A Home Switch Input Input 4 Counterclockwise End of Travel Limit Input 56 Chapter

57 0K 0K 0K Installation and Configuration 5V J03- J03-4 J03- CW LMT CCW LMT HM LMT 0K 0K 0K UF.0UF.0UF Figure -30: End of Travel Limit Interface Input (J03) Chapter 57

58 Installation and Configuration End Of Travel Limit Phasing If the EOT limits are reversed, you will be able to move further into a limit but be unable to move out. To correct this, swap the connections to the CW and CCW inputs at the motor feedback connector. The logic level of the EOT limit inputs may be viewed in the Diagnostic Display (shown in Figure -3). Figure -3: Limit Input Diagnostic Display 58 Chapter

Ndrive CP Hardware Manual

Ndrive CP Hardware Manual Hardware Manual Revision: 4.07.00 ENB/FLT MARKER PWR INPOS ENB/FLT MARKER PWR INPOS TB20 AGND AIN+ AIN- AOUT J0 FIREWIRE J02 FIREWIRE J0 J02 OP OM 0 2 3 4 5 6 7 OPTO OUT TB202 MOTOR FEEDBACK J03 TM A3200

More information

Soloist HPe 10/20/30 Hardware Manual

Soloist HPe 10/20/30 Hardware Manual Soloist HPe 0/0/30 Hardware Manual Revision: 4.07.00 85-40V~ 50/60Hz A MAX NC C NO TB30 85-40V~ 50/60Hz A MAX CONTROL SUPPLY MOTOR SUPPLY MOTOR OUTPUT EXTERNAL SHUNT AC AC AC AC A B C 40V~ MAX 50/60Hz

More information

Ndrive MP Hardware Manual

Ndrive MP Hardware Manual Hardware Manual Revision: 4.08.00 TM A3200 AEROTECH. COM TM A3200 AEROTECH. COM J20 J0 J0 FIREWIRE FIREWIRE J02 J02 ENA MRK CTL POS ENA MRK CTL POS 4 TB20 TB202 MOTOR FEEDBACK 4 J03 OPTO IN MOTOR FEEDBACK

More information

Ndrive ML Hardware Manual

Ndrive ML Hardware Manual Hardware Manual Revision:.09.00 TM A3200 AEROTECH. COM TM A3200 AEROTECH. COM J20 J0 J0 FIREWIRE FIREWIRE J02 J02 ENA MRK CTL POS ENA MRK CTL POS 4 TB20 TB202 4 OPTO IN MOTOR FEEDBACK MOTOR FEEDBACK J03

More information

Npaq MR Hardware Manual

Npaq MR Hardware Manual Npaq MR Hardware Manual P/N: EDU210 Revision: 1.07.00 AEROTECH.COM ON OFF Npaq MR FEEDBACK COMMUNICATIONS EXT DRIVE RS232 AUX ENCODER JOYSTICK 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5

More information

Ndrive Linear Series. Digital Servo Amplifiers Linear. Output power range of 10 or 20 A peak with ±10 to ±80 VDC bus

Ndrive Linear Series. Digital Servo Amplifiers Linear. Output power range of 10 or 20 A peak with ±10 to ±80 VDC bus Ndrive Linear Amplifiers/Drives Ndrive Linear Series Digital Servo Amplifiers Linear Output power range of 10 or 20 A peak with ±10 to ±80 VDC bus 2- or 3-phase AC line input or DC input CE approved and

More information

Ensemble LAB Hardware Manual

Ensemble LAB Hardware Manual Ensemble LAB Hardware Manual Revision: 1.02.00 JOG 1 2 3 USB 4 4 3 2 1 AXIS AUX I/O JOYSTICK ESTOP USB ETHERNET WARNING: HAZARDOUS VOLTAGE PRESENT UP TO 10 MINUTES AFTER POWER IS DISCONNETED J106 J105

More information

Ensemble Linear Series

Ensemble Linear Series Motion Controllers Ensemble Linear Ensemble Linear Series Networked, Panel-Mount Drives Linear Network drives through a high-speed serial interface to coordinate up to ten axes of motion Coordinate motion

More information

HEX RC Hardware Manual

HEX RC Hardware Manual HEX RC Hardware Manual Revision: 1.00.00 AEROTECH.COM ON OFF HEX RC Powered by A 320 0 USB USB2 USB3 ETHERNET FIREWIRE DVI DIGITAL / ANALOG IO 1 2 MPGA ESTOP 1 2 MOTOR / FEEDBACK 3 4 5 6 Global Technical

More information

Soloist Linear Series

Soloist Linear Series Soloist Linear Series Position Controller and Servo Amplifier Linear Single axis digital servo controller with integral power supply and amplifier Advanced software architecture shortens customer development

More information

Npaq Hardware Manual. Revision:

Npaq Hardware Manual. Revision: Npaq Hardware Manual Revision: 3.06.00 Global Technical Support Go to www.aerotech.com/global-technical-support for information and support about your Aerotech products. The website provides downloadable

More information

Soloist Linear Series

Soloist Linear Series Soloist Linear Series Position Controller and Servo Amplifier Linear Single axis digital servo controller with integral power supply and amplifier Advanced software architecture shortens customer development

More information

Soloist. Position Controller and Servo Amplifier. Single axis digital servo controller with integral power supply and amplifier

Soloist. Position Controller and Servo Amplifier. Single axis digital servo controller with integral power supply and amplifier Soloist Series Motion Controllers Soloist Position Controller and Servo Amplifier Single axis digital servo controller with integral power supply and amplifier Advanced software architecture shortens customer

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

Ensemble QLe Hardware Manual Revision:

Ensemble QLe Hardware Manual Revision: Ensemble QLe Hardware Manual Revision: 1.03.00 ETHERNET J101 ENB/FLT PWR USB J102 SYNC J103 AUX I/O J108 A B AERONET OUT J104 IN J105 ANALOG I/O J107 POWER INPUT AC1 STAGE J106 AC2 TB101 100-240V~ 50/60Hz

More information

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available ECM40-60 40 & 60 Watt Models Small Size 2.0 x 4.0 x 1.2 Low Leakage Current Industrial & Medical Approvals Full Load Available Convection Cooled Wide Operating Temperature 0 C to +70 C Level B Conducted

More information

Ensemble QLAB Hardware Manual

Ensemble QLAB Hardware Manual Ensemble QLAB Hardware Manual Revision: 1.01.00 JOG 1 2 3 USB 4 4 3 2 1 AXIS AUX I/O JOYSTICK ESTOP USB ETHERNET WARNING: HAZARDOUS VOLTAGE PRESENT UP TO 10 MINUTES AFTER POWER IS DISCONNETED J106 J105

More information

Motion Controller. MXC Series Multi-Axis Motion Controller Compact Motion Controller with up to 6 Axes of Control

Motion Controller. MXC Series Multi-Axis Motion Controller Compact Motion Controller with up to 6 Axes of Control MXC Series Multi-Axis Motion Controller Compact Motion Controller with up to 6 Axes of Control Allied Motion s MXC motion controller is a very compact, multi-axis servo and/or step motor motion controller,

More information

Ndrive QLe Hardware Manual Revision:

Ndrive QLe Hardware Manual Revision: Ndrive QLe Hardware Manual Revision: 1.03.00 ENB/FLT PWR SYNC J103 AUX I/O J108 A B S1 DEVICE NUMBER ON 5 4 3 2 1 0 J104 J105 ANALOG I/O J107 FIREWIRE POWER INPUT STAGE J106 AC1 AC2 TB101 100-240V~ 50/60Hz

More information

Nservo. Digital Controller Module. Use to retrofit your existing system with new controls extend the life of your capital investment

Nservo. Digital Controller Module. Use to retrofit your existing system with new controls extend the life of your capital investment Nservo Digital Controller Module Use to retrofit your existing system with new controls extend the life of your capital investment Supports 2 (standard) or 4 closed-loop servo axes Each axis has three-phase

More information

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES INSTRUCTION MANUAL KEPCO An ISO 9001 Company. 300 WATT, PFC, OPEN FRAME POWER SUPPLIES RMW 300W SERIES I INTRODUCTION SCOPE OF MANUAL. This instruction manual covers the installation and operation of the

More information

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW) Characteristics soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW)/500V(45kW) Price* : 683.00 GBP Main Range of product Altistart 22 Product or component type Product destination Product

More information

Digital DRIVE for Brushless motor MD Serial

Digital DRIVE for Brushless motor MD Serial Digital DRIVE for Brushless motor MD Serial Installation guide Read manual before installing and respect all indications with this icon: MD-GI/EN Table of Contents 1- Introduction... 3 1-1- Warning...

More information

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW) Characteristics soft starter-ats22-control 220V-power 230V(15kW)/400...440V(30kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

Ndrive QL andqle Digital Panel-Mount Piezo Drive

Ndrive QL andqle Digital Panel-Mount Piezo Drive Ndrive QL and QLe Amplifiers/Drives Ndrive QL andqle Digital Panel-Mount Piezo Drive Real-time distributed control architecture allows synchronized motion control on up to 32 axes of piezo and/or servo

More information

Universal Power Supplies

Universal Power Supplies , Features Universal input: 90 264 VAC or 120 30 VDC Active power factor correction (>0.95) High efficiency up to 93% Load share function for up to 3 units in parallel Adjustable output voltage EMI/EMC

More information

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC) Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger Medical PV Railway PART NUMBER STRUCTURE T A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW) Product data sheet Characteristics ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/400...440V(37kW) Complementary Assembly style Function available Power supply voltage limits Main Range of

More information

Features. Applications and Benefits TRC ELECTRONICS, INC

Features. Applications and Benefits TRC ELECTRONICS, INC Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - on base plate Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific

More information

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics. Characteristics soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

P216. Condenser fan speed controller. Product bulletin. Features

P216. Condenser fan speed controller. Product bulletin. Features P216 Condenser fan speed controller Product bulletin These controllers are designed for speed variation of single phase motors, especially for fan speed control on air cooled condensers. Head pressure

More information

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications. The ABC60 Series of AC-DC open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 60 W of output power and a variety of single and multiple output

More information

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Characteristics softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp) Main Range of product Altistart 22 Product or component type Product destination Product specific application

More information

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability The MCC600 Series of open-frame medical power supplies, with its wide universal 85-264 VAC input range, is available at 600 W of output power and a variety of single output voltages. The MCC series is

More information

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Installing Your 1394 Drive Interface Module

Installing Your 1394 Drive Interface Module Installation Instructions Installing Your Drive Interface Module (Catalog Number -DIM) Introduction This publication provides installation instructions for adding the Drive Interface Module to your system.

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter Click on Series name for product info on aimtec.com Series AMER120-AZ FEATURES: AC-DC Constant Current or Constant Over Current Protection Voltage LED Driver Short Circuit Protection Input range 90-305VAC/47-440Hz

More information

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3. Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /

More information

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals. 4- Watts ECM Series Compact Size xppower.com IT & Medical Approvals Convection-cooled Class I and II Construction DC Input Version Available (DCM Series) PoE Isolation Version Available (POE Series) 3

More information

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D47S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter Features Regulated Converter Description Universal input -264VAC Efficiency up to 86% Short circuit and over voltage/current protected UL/EN9 certified, CE marked Conformal coated product The RAC35-xxG/OF

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Enclosed Power Supplies

Enclosed Power Supplies , 15 150 Watt Features Very compact metal cased power supplies High operating temperature up to 70 C Low no load power consumption

More information

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24 Features Gelo LED power supplies are designed specifically for use in LED lighting, particularly well-suited for refrigeration, retail display and sign applications. The industry standard footprint and

More information

Gelo LED Driver 100W, Single output RGLD100-24

Gelo LED Driver 100W, Single output RGLD100-24 Features Gelo LED power supplies are designed specifically for use in refrigeration, retail display and sign applications. The industry standard footprint and very low profile design provide great benefits

More information

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink Product datasheet Characteristics ATV12H075M3 variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - with heat sink Complementary Main Range of product Altivar 12 Product or component type Product

More information

CompactBlock Guard I/O EtherNet/IP Safety Modules

CompactBlock Guard I/O EtherNet/IP Safety Modules Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW) Characteristics soft starter-ats22-control 220V-power 230V(110kW)/400...440V(220kW) Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart 22 Product

More information

Rhino PSM Power Supplies. Operating Instructions

Rhino PSM Power Supplies. Operating Instructions Rhino PSM Power Supplies Operating Instructions RHINO Power Supplies PSM Series Description The PSM power supplies are built-in units. The mounting position for PSM power supplies must fulfill the requirements

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC) 180 Watt Industrial Features 4 x 2 x 0.75 Inches Form factor 180 Watts with Forced Air Cooling Efficiencies upto 92% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature

More information

AG300 Family CTL01-3A-03, AMP01-2A-02

AG300 Family CTL01-3A-03, AMP01-2A-02 AG300 Family CTL01-3A-03, AMP01-2A-02 Hardware User's Manual Page 1 Revision control table Version Description Date 1.0 Initial (based on Hardware Manual of previous hardware versions) April 27, 2016 1.1

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

Industrial Power Supplies

Industrial Power Supplies , Rugged metal case for harsh industrial environments Industrial operating temperature range: 25 C to +70 C Overload and and overtemperature protection Power boost up to 120 % Power-Good signal Shock and

More information

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation. Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS Line A Inverse parallel scrs Load a Line B COMPACT SCR POWER CONTROLLERS O delta Line c inverse parallel scrs Load C 1 Compact Brochure Rev 3.51 www.ccipower.com 1-800-765-2799 FEATURES Auto-Ranging Input

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

MVAD040 Series 40W 2 x 4 AC-DC Power Supply Converter www.murata-ps.com MVAD040 Series DESCRIPTION The MVAD040 series switching power supplies utilize advanced component and circuit technologies to deliver high effi ciency. Designed for Medical, Telecom,

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC) 180 Watt Medical Features 4 x 2 x 0.75 Inches Form factor 180 Watts with Forced Air Cooling Approval to EN60601 3rd Edition Efficiencies upto 92% -40 to 70 degree operating temperature* Dual fusing 12V

More information

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22C17Q Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157 PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History SPECIFICATION FOR SWITCHING POWER SUPPLY M/N: Revision History Version Date Change Items Rev. 1.0 July.21. 2017 Established. Page 1 Models & Ratings FEATURES 650W medical power supply with force air cooling.

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC) 225 Watt Industrial Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature

More information

MDM 011-Z1 Regen Resistor

MDM 011-Z1 Regen Resistor MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18

More information

Appendix E: Edge Ti. Overview. Appendix E: Edge Ti 169

Appendix E: Edge Ti. Overview. Appendix E: Edge Ti 169 Appendix E: Edge Ti 169 Appendix E: Edge Ti Overview The Edge Ti shape cutting control is an extremely versatile product offering up to four configurable axes of motion, built-in Servo Amplifiers and configurable

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TBLC Series, 6 90 W Low profile case, module depth only 55 mm Suitable for mounting in domestic installation panels Very high efficiency and low standby power -> compliance to

More information

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter Click on Series name for product info on aimtec.com Models Single output Model Input Voltage (VAC/Hz) FEATURES: Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum

More information

Integrated Stepper Drive & Motor

Integrated Stepper Drive & Motor SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a

More information

M/V Series Digital Servo Drive DVC250A060

M/V Series Digital Servo Drive DVC250A060 Description Power Range The DVC250A060 DigiFlex Performance digital servo drive is designed to drive brushed, brushless, and AC induction servomotors from a compact form factor ideal for embedded applications.

More information

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Models Single output Model (VAC/Hz) (VDC) Output Voltage (V) Output Current max (A) Efficiency (%) AMES40-3.3SMAZ 90-264/47-440 130-370 3.3

More information

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact Characteristics variable speed drive ATV320-0.75kW - 200...240V - 1 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES KEPCO INC. An ISO 9001 Company. MODEL RA 55 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for

More information

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS SEE SAFETY WARNING ON PAGE 6 SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY IS DESIGNED TO BE USED WITH KBAC 3G SERIES DRIVES ONLY KBAC 3G SERIES MODELS CONTAIN THE "(3G)" DESIGNATOR ON THE PRODUCT LABEL

More information

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

VER05 Series. xxx Series. 5 Watt.   AC-DC Power Supplies. Models & Ratings. Input. Output 5 Watt xxx Series Energy Efficiency Level VI Barrel Jack & USB Versions Interchangeable Mains Connectors Included Universal Input Output Voltages from 5.0 V to 12.0 V Class II Construction Low Cost B R

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number

More information

RoboClaw 2x30A Dual Channel Motor Controller

RoboClaw 2x30A Dual Channel Motor Controller RoboClaw 2x30A, 34VDC Dual Channel Brushed DC Motor Controller Version 2.2 (c) 2016 Ion Motion Control. All Rights Reserved. Feature Overview: 60 Amps Peak Per Channel Channel Bridging Supported Dual Quadrature

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

Stand-Alone, Multi-Axis Motion Controller

Stand-Alone, Multi-Axis Motion Controller Ensemble LAB Stand-Alone, Multi-Axis Motion Controller Up to 4 axes of brush, stepper or brushless DC motors Aerotech s FlashConfig feature automatically configures axis parameters based on the connected

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

A range of brushless servo drives with optional controllers

A range of brushless servo drives with optional controllers SV-S & SVHX-S series servo drives A range of brushless servo drives with optional controllers SV-S and SVHX-S Series intelligent servo drives combine advanced microprocessor control with established analogue

More information

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter Click on Series name for product info on aimtec.com FEATURES: I/O Isolation 4000 Energy Star compliant Operating Temp: -40 o C to +70 o C Ultra-small package Over load, Over, Short Circuit Protection Up

More information

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

GSP750 Series. 750 Watts.   AC-DC Power Supplies. Models & Ratings. Input C-DC Power Supplies 750 Watts 900 W Peak Power Rating for 100 ms Universal 80-264 VC Input IT & Medical Safety pprovals 1.0 W Standby Power -40 C to +70 C Operation Remote On/Off 5 V/3 Standby Output 3

More information

P216 Series Condenser Fan Speed Controller

P216 Series Condenser Fan Speed Controller P216 Series Condenser Fan Speed Controller Installation Instructions P216xxx-x Part No. 24-85895-18, Rev. D Issued 27 August 2015 Applications Refer to the QuickLIT website for the most up-to-date version

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

Hardware Manual 1240i-485

Hardware Manual 1240i-485 Hardware Manual -485 Intelligent Step Motor Driver with Multi-drop RS-485 Interface 920-0033 A 7/6/2010 motors drives controls -2- Table of Contents Introduction...4 Features...4 Block Diagram...4 Getting

More information

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction ACOPOSinverter P74 User's Manual Version: 2.20 (August 2016) Model no.: MAACPIP74-ENG Original instruction All information contained in this manual is current as of its creation/publication. We reserve

More information