Smart Combiner Installation Manual
|
|
- Britney Thomas
- 5 years ago
- Views:
Transcription
1 Smart Combiner Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA ph fax
2 Copyright 2012 SolarBOS, Inc. All rights reserved. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photographic, magnetic, or otherwise, without the prior written permission of SolarBOS, Inc. SolarBOS makes no representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such warranties are expressly disclaimed. SolarBOS is not liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.) Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Users are cautioned, however, that SolarBOS reserves the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. Revision History Rev. No. Date By Description June 2012 DK Preliminary Release August 2012 DK Production Release Nov 2012 ST Termite Settings March 2013 AO Field Cal, COM Port SolarBOS, Inc. 310 Stealth Court Livermore CA ph fax 1
3 IMPORTANT SAFETY INSTRUCTIONS ***SAVE THESEE INSTRUCTIONS*** This manual contains important instructions for all SolarBOSS smart combiner models that must be followed during the installation and usee of the smart combiner. The smart combiner are designed and testedd according to international safety requirements. As with all electrical and electronic equipment,, certain precautions must be observed when installing the smart combiner. To reduce the risk of personal injury and to ensure the safe installation and operationn of the smart combiner, you must carefully read and follow all instructions and warnings in this Installation Guide. Safety and Hazard Symbols This symbol appears besidee instructions and warnings that deal with dangerous voltages that can injure peoplee who come in contact with them. Warnings WARNING: A warning describes a hazardd to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the SolarBOSS equipment and/or other equipment connected to the SolarBOS equipment or personal injury. Warnings may also be accompanied by one or more of the safety and hazard symbols described above to indicate the type of hazard described therein. Other Symbols In addition to the safety and hazard symbols described previously, the following symbol is also used in the Installation Guide: This symbol accompanies notes that calll attention to supplementary information that you should know to ensure optimal operation of the system. This GROUND symbol marks areass in the combiner equipment grounds only. for connecting 2
4 Warranty All smart combiner sold in the USA have a five-yearr warranty. For warranty coverage, or if you have questions about the smart combiner warranty, contact SolarBOS at the address, telephonee number, or web site listed on page 1 (to send , seee the contact section of the SolarBOS web site: WARNING: All electrical installation must be done in accordance with the National Electrical Code ANSI/NFPA 70, local building codes, and the requirements of the authority having jurisdiction. WARNING: To prevent electrical shock or injury, all wiring and commissioning procedures must be performed by qualified personnel. WARNING: Before installing or using the smart combiner, read all of the instructions and warnings on the combinerr and in this Installation Guide. WARNING: PV arrays producee electrical energy when exposed to light and thus create an electrical shock hazard. WARNING: The smart combinerss use an integrated disconnect switch, yet both the line and load side of the switch may still be energized in the OFF position. Always test both sides of the disconnect before servicing the smart combiner. 3
5 Introduction SolarBOS has introduced a new line of smart combiners designed for use with all module and inverter combinations. Combiner features include: Listed to UL 1741 Simplified input and output wiring Compact, low-cost, and flexible design Available in NEMA 3, 3R, 4 powder-coated steel, and NEMA 4X stainless steel or fiberglass enclosures (others available upon request) Integrated current sensing module Integrated load-break disconnect switch (optional) Integrated load-break contactor switch (optional) Unpacking and Inspection All SolarBOS smart combiners are thoroughly checked before they are packaged and shipped. Although they are shipped in sturdy packaging, damage can still occur during shipping and delivery. It is important to carefully inspect the shipping container and contents prior to installation. If you detect any external damage after unpacking, report the damage immediately to SolarBOS and the shipping company that delivered the unit. Items not rejected within 10 days of delivery are considered accepted without recourse. If it becomes necessary to return the combiner, please use the original packing material. If you need assistance in dealing with a damaged unit, contact SolarBOS at
6 Smart Combiner Options There are three versions of the SolarBOS smart combiner: the standard combiner (Figure 1), the disconnect combiner (Figure 2) and the contactor combiner (Figure 3). Figure 1. SolarBOS Smart Standard Combiner Figure 2. SolarBOS Smart Disconnect Combiner Figure 3. SolarBOS Smart Contactor Combiner 5
7 Installation Refer to Figure 4 and Table 1 for enclosure dimensions. Use appropriate hardware for the mounting surface. The dimensions of the unit for each smart combiner option and the respective weights are shown in Table 1 below. Figure 4. Combiner Enclosure Dimensions Table 1. Smart Combiner Dimensions Enclosure Type # of Circuits H W D X Y Weight (lbs.) Standard Contactor Disconnect N3/N N3/N N3/N XF N/A N/A 4XF N/A N/A 4XF N/A N/A 4XF N/A XF N/A XF N/A All dimensions are in inches unless otherwise noted. 6
8 Input Wiring Refer to Figure 5 and Table 2 for the input wiring locations of the smart combiner. PV positive and negative conductors are wired into the positive lug and negative distribution block, respectively. These terminal locations are clearly marked. All PV safety ground conductors are wired into the ground bus located att the bottom of the smart combiner. NOTE: The smart combiner enclosure is shipped with no entry holes. A knock-out is required for the appropriate conduit size. SolarBOS recommends wire entry to be made according to Figure 5. Output Wiring Many of our smart combiners have large fault current ratings. When temperaturee and voltage drop adjustments are considered, the outpu conductor sizes can become quite large (500 MCM or greater) and difficult to manage. NEC Article allows paralleling of conductors greater than AWG 1/0 to achieve higher ampacities. NOTE: On units with provision for using crimp lugs use Panduit part number LAA for 250MCM wire or a ULL listed equivalent part from another manufacturer. Be sure to use the appropriate partt number for the intended wire gauge. NOTE: Rain tight or wet location hubs that comply with the Standard UL514B must be used for NEMA 3/3R outdoor applications. NEMA 4 or 4X applications must use watertight hubs that comply withh the Standard UL514B. Use Myers- 2 type, water-tight conduit fittings such ass Thomas & Betts H200TB (for conduit) or H300TB (for 3 conduit) or equivalent from others. Install fittings per manufacturer s recommendations. 7
9 Wire Entry Locations Figure 5. Combiner Wire Entry Locations Dimension A and B are for input wire locations. Dimensions C and D are for output wire locations. These locations are recommendations only. Care should always be taken to assure there is enough wire bend space for the desired output wire gauge when choosing a conduit entry location. The wire entry locations for the standard, contactor and disconnect combiners are shown in Table 2a, Table 2b, and Table 2c respectively. Wire Entry Dimensions Table 2a. Standard Combiner Enclosure Type # of Circuits A B C D N3/N N3/N N3/N XF XF XF Table 2b. Contactor Combiner Enclosure Type # of Circuits A B C D N3/N N3/N N3/N XF XF XF Table 2c. Disconnect Combiner Enclosure Type # of Circuits A B C D N3/N N3/N N3/N XF XF XF All dimensions are in inches unless otherwise noted. 8
10 The Channel Map The following schematic shows the channel map for the PV string inputs for up to 8, 12 and 16 channels. (a) (b) (c) Figure 6: Input wire labeling schematic for (a) 8 strings, (b) 12 strings, and (c) 16 strings The monitoring website will display PV string current readings according to the channel map shown above. PV String Fuses All SolarBOS smart combiners ship with fuses installed according to the user s predetermined requirements. All fuses and connection points are electrically tested prior to shipment. SolarBOS maintains stock of common fuse sizes if replacements are necessary or spares desired. WARNING: Never open a fuse holder while it is under load. Electrical arcing and damage to the fuse holder will occur if a fuse holder is opened under load. 9
11 The Current Sensor Module The smart combiner includes a current sensor module located on top of the bus bar in between the fuse holders as shown in Figure 6. The unit requires a 24V DC power supply available separately from SolarBOS. The module measures the current of each circuit and outputs this information via Modbus/RS-485. Wiring The output from the current sensor module is RS-485 serial using the standard Modbus RTU protocol. The positive data out, negative data out and data shield should be wired to the RS-485 network. The (24V DC in) is wired to the power supply. Minimum wire size of 24 AWG is required for RS-485 communications. The 24V DC wire should be sized based on distance and number of combiners. 2 1 Figure 7. The SolarBOS Smart Combiner includes a manual push button (1) and monitoring unit input terminals (2). 10
12 Field Calibration After hardware installation (combiner completely installed and wired), it is necessary to calibrate the current sensors. Two calibrations must be performed: 1) a zero calibration and 2) an all on calibration. The manual push button (Item 1 in Figure 7) is used to access the calibration menu, tare the current sensors, and enter an operating current for the all on calibration. The push button location may vary by model. Zero Calibration 1. Ensure no current is flowing through any of the combiner circuits (open disconnect or turn off the contactor bypass switch). 2. Press and hold the button for 3 seconds (until all channel lights turn on), then release. The light on channel 1 (upper left-most light) will stay lit, indicating zero calibration mode (see figure 8.1) 3. With the channel 1 light still lit, Press and hold the button for 3 seconds (until channel 1 light flashes), then release. The sensor board will cycle through all channels setting the zero point on each. Figure 8.1. Channel 1 light on. All On Calibration 1. Ensure current is flowing to all wired channels (close disconnect or contactor). Each string must be running at 4 amps or greater in order for the monitoring board to identify active channels. 2. Verify each active string is at its expected current and greater than 4 amps with a DC current clamp. 11
13 3. Hold the push button (Item 1 in Figure 7) for 3 seconds, until all channel lights are lit, then release. 4. The light on channel 1 will stay lit. Push the button once to select the light on channel 3 which activates all on calibration. Refer to figure 6 for channel layout. 5. With channel 3 lit, hold the button for 3 seconds until the channel 3 light blinks. Then release. 6. The board is now in all on calibration mode, and you are ready to enter the total current. Measure the total current through all strings with a DC current clamp (5 strings at 8 amps each should yield a total current of 40 amps). 7. The light on channel 10 should be lit, indicating a zero place value. Subsequent presses of the button will advance the light through 1-9. During all on calibration, the board expects a 3 digit number. For boxes with total current under 100 amps, you must first enter a 0. Ex: 85 amps enters as 085. Select the first digit (0-9), then hold the tare button for 3 seconds. The selected value will flash, and then string 10 will light up indicating it is time to enter the next digit. For an example of light indicators for 085 see figure 8.2. Figure 8.2. Light configurations for '085' Figure 8.3. Channel lights correctly indicating active and inactive channels. (5,10,11 inactive) 12
14 8. After all 3 digits have been entered, the board will verify the entered values by flashing each digit one time. Then, the board will calibrate each channel one by one, and then will light up all active channels simultaneously. During this process, 1) verify the total current value was entered correctly and 2) the board properly identifies all active and inactive channels. For an example of active channel verification, see Figure 8.3. Exiting the Calibration Menu To exit the Calibration Menu, press the pushbutton repeatedly until the Chanel 7 light is lit (4 th light from the upper left). Press and hold the button for 3 seconds until all lights flash. The current sensor module is now in run mode. Note: These calibration steps MUST be performed in order to ensure accurate readings of string currents. 13
15 Setting the Modbus Address The user can access monitoring data on a computer by downloading the Termite 2.9 software at After the Termite 2.9 software is installed, follow the instructions listed below. 1. Remove the SolarBOS bus bar cover from the monitoring apparatus. 2. Plug the USB 2.0 cable into the port on the control board and the USB end to your USB port on your PC. 3. Open Termite 2.9 software. 4. Termite settings below are necessary for proper communication with SolarBOS smart board. a) Port: The port number may vary between boards. With Windows 7, one of the following steps may be necessary to identify the correct port: i) Install Windows USB driver from the following URL before plugging the sensor board into the USB port. ii) If a Windows add new hardware dialog comes up when you plug the sensor in, point to the following.inf file: Once a driver is installed, a new COM port will show up in Termite when the sensor board is plugged in. 5. Press and hold the small green button near the USB port. 6. While still holding the green button near the USB port, click the main button in the Termite program that states Disconnect click to connect located at the top left corner. 7. When the button states Waiting for port, release the small green reset button. 14
16 8. The menu will appear as shown in Figure 9. Figure 9. SolarBOS Current Sensor Menu 9. To change the Modbus address, type 2 into the text bar located at the bottom of the Termite window shown in Figure 10. Figure 10. SolarBOS Current Sensor text bar 15
17 10. Then, type the addresss in the text box and press enter. The program will automatically re-generate the menu as shown in Figure 10 below. Figure 11. SolarBOS Current Sensor text barr Smart Combiner Orientation n NEMA-3/4/4X enclosures may be installed in either the vertical or the horizontal orientation. This applies to smart combiners with the N3 N4 4XF and 4XSS designation. If installed horizontally (with the door facing the sky), they should be supported by appropriate mounts. WARNING: Do not install the smart combiner directly to the roof material. Doing so will void the warranty. Disconnect Switch Assembly The disconnect or contactor models of the smart combiner include a handle installed on the enclosure door with clearly marked ON and OFF positions. The switch handle (located on the enclosure door) allows padlockingg in the OFF position enabling Lock Out/Tag Out procedures. 16
18 Defeating the Disconnect Handle For some applications, it may be necessaryy to temporarily defeat the integrated disconnect switch on the smart combiner. With the switch on, the handle door interlock mayy be defeatedd with a tool to allow the door to be opened. The door interlock may be defeated in the ON position but reactivates automatically when the enclosure door is closed. See item 1 on Figure 7. With the enclosure door open, it is possible to operate the switch with an auxiliary handle by defeating the handle interlock without using a special tool. Figure 7. Defeating the Disconnect Switch WARNING: Only qualified personnel should defeat the handle interlock on the smart combiner. door 17
Smart Combiner Box Installation Manual. SolarBOS, Inc. 310 Stealth Court Livermore CA ph fax
Smart Combiner Box Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA 94551-9552 925-456-7744 ph. 925-456-7710 fax www.solarbos.com 1 Copyright 2013 SolarBOS, Inc. All rights reserved. All
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationInstallation Manual SMA RS485 MODULE
Installation Manual SMA RS485 MODULE MD.485-US-40 (PC-485.BG1) ENGLISH MD485-US-40-IA-en-10 Version 1.0 Legal Provisions SMA Solar Technology America LLC Legal Provisions No part of this document may be
More informationPV Inverter SUNNY BOY 2000HF-US/2500HF-US/3000HF-US
PV Inverter SUNNY BOY 2000HF-US/2500HF-US/3000HF-US User Manual HF_STP_US-BUS095110 TBUS-20HF Version 1.0 CA US Power curve or energy curve of the past 16 feedin hours or past 16 days (switching the display
More informationDANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.
Installation/Operation Manual TABLE OF CONTENTS Page UNPACKING AND INSTALLATION Unpacking and Preliminary Inspection...2, 3 Model Number...9 LOCATION CONSIDERATIONS Environment, Equipment Performance,
More informationInstall Motor Controller User Manual
Property of Motion Laboratories, Inc. Install Motor Controller User Manual 2014 Motion Laboratories, Inc. Created By: Michael Shaw Approved By: John Coppolecchia Page: 1 Page: 2 2014 Motion Laboratories,
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationhdpv.org Ampt Communications Unit Installation Manual D
hdpv.org Ampt Communications Unit Installation Manual 57070008-1 D 2 Copyright 2016-2019 Ampt LLC. All rights reserved. No part of this document may be reproduced, retransmitted, or copied in any form
More informationSIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018
SIRIUS CAPACITOR MODULE User Manual Model number: 3550-48-A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 Introduction The Sirius Capacitor Module ( Sirius ) is supercapacitor-based storage that uses
More informationSpecifications, Installation, and Operating Instructions
Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.
More informationDual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02
Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These
More informationConext CL-60 Inverter Firmware Upgrade Process
Conext CL-60 Inverter Firmware Upgrade Process http://solar.schneider-electric.com 976-0380-01-01/B August 2017 Application Note EXCLUSION FOR DOCUMENTATION UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationIO-AO6X I/O Expansion Module 6 Isolated Analog Outputs
IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated
More informationCentral Inverter MV POWER PLATFORM 1.0 MW / 1.25 MW / 1.44 MW MV POWER PLATFORM 1.5 MW / 1.6 MW Enclosure Version without Disconnect Unit
Central Inverter MV POWER PLATFORM 1.0 MW / 1.25 MW / 1.44 MW MV POWER PLATFORM 1.5 MW / 1.6 MW Enclosure Version without Disconnect Unit Installation Manual MVPP_E-IA-US_en-10 98-4033310 Version 1.0 US
More informationInstallation Manual SMA SENSOR MODULE
Installation Manual SMA SENSOR MODULE ENGLISH MDSEN-US-40-IA-en-11 Version 1.1 Legal Provisions SMA Solar Technology America LLC Legal Provisions No part of this document may be reproduced, stored in a
More informationInstruction Manual: IM E
Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationMulti Unit Enclosed Meter
Contents Description Page Introduction Preliminary comments and safety precautions............................... 2 Warranty and liability information................ 2 Safety precautions..............................
More informationINSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationInstallation Instructions & User Manual
Installation Instructions & User Manual ZONEMASTER PRO AC Panel Transient Voltage Surge Suppressors The Wiremold Company In US: 60 Woodlawn Street, West Hartford, CT 06110 800-621-0049 FAX 860-232-2062
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationINSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)
Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationInstallation Instructions
50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide
More informationInstallation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2
Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationObtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx
Preface Obtaining Documentation and Submitting a Service Request, page xvii Safety s, page xvii Safety Guidelines, page xx Obtaining Documentation and Submitting a Service Request For information on obtaining
More informationInstallation Manual Updated May 2017
Code No. LIT-12012114 Installation Manual Updated May 2017 JC-VSD Factory Packaged (FP) Series II drive frames 4 8, Type 1 and 3R Johnson Controls variable speed drives Disclaimer of warranties and limitation
More informationUSB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1
USB 2.0 SR Extender over one CAT-5 Cable EXT-USB2.0-SR User Manual Version A1 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions.
More informationAccessories for Sunny Central Disconnect Unit for Sunny Central 250U / 500U / 500HE-US/CA and Sunny Central CP
Accessories for Sunny Central Disconnect Unit for Sunny Central 250U / 500U / 500HE-US/CA and Sunny Central CP Installation Guide DisconACDC_SCUS-IUS103110 98-4009010 Version 1.0 US 2 DisconACDC_SCUS-IUS103110
More informationSurge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL
LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND
More informationNSD/M1 Installation Instructions
NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationQuick Start Guide TS 870 ATS
Quick Start Guide TS 870 ATS 100A - 800A (with TSC 900 Controller) DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating
More informationIRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-MON UNIVERSAL SAFETY PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationSystem Manual COMPACT MV POWER PLATFORM
System Manual COMPACT MV POWER PLATFORM CoMVPP-SH-US_en-20 98-126200.01 Version 2.0 AMERICAN ENGLISH Legal Provisions SMA America, LLC Legal Provisions Copyright 2014 SMA America, LLC. All rights reserved.
More informationTotal Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400
Total Protection Solutions SurgeTrack Series: 080, 120, 160, 240, 300 and 400 Surge Protective Devices Installation, Operation and Maintenance Manual SURGETRACK INSTALLATION, OPERATION AND MAINTENANCE
More informationZC Series Zone Monitoring Controllers
ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Product 7160-0318-00 THROUGH 7160-0318-12 PANASONIC TOUGHBOOK CF-31 DOCKING STATION This instruction sheet is for the following products: Panasonic Toughbook CF-31 docking station
More informationCEM M-RS485 INSTRUCTION MANUAL (M014B A)
Communications interface CEM M-RS485 INSTRUCTION MANUAL (M014B01-03-14A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could
More informationUPS READY POWER DISTRIBUTION ASSEMBLY
UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of
More informationM250 (M LL) Safety
M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical
More informationApplication Note on Modifying Disconnect Settings for Xantrex GT Series Single Phase Inverters and Conext TX Series Inverters
Application Note on Modifying Disconnect Settings for Xantrex GT Series Single Phase Inverters and Conext TX Series Inverters 976-0312-01-01 Revision A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More informationORB TM 4-20 ma Input Box Installation & Operation Manual
IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling
More informationINSTALL INSTRUCTIONS RSXMR-9886-P-48
INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installation Instructions RSXMR-9886-P-48 (CEQ. 20194) INSTALL INSTRUCTIONS RSXMR-9886-P-48 Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationBCM2 Series Branch Circuit Monitors Quick Setup Guide
BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationFC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions
FC-29W 9 UN-UNIVERSAL Dome Housing Installation Instructions 1 Safe Use of Equipment WARNING WARNING To reduce the risks of an electric shock, do not expose inside of this unit to rain or moisture. Installation
More information1:4 3GSDI Splitter. User Manual EXT-3GSDI-144. Release A5
1:4 3GSDI Splitter EXT-3GSDI-144 User Manual Release A5 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationM215 (M215-60) Safety
M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To
More informationIRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 MONITORED DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More information4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationAgilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable
Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable Installation Note The 38-pin probe and adapter cable provide a convenient way to connect two Agilent Technologies logic analyzer
More informationAgilent Technologies E5339A 38-Pin Low-Voltage Probe
Agilent Technologies E5339A 38-Pin Low-Voltage Probe Installation Note The 38-pin low-voltage probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a small
More informationOPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES
PRICE: $25.00 LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES www.unipowertelecom.com Manual No. LVD-201-2 8/29/01/L46Man 2001 UNIPOWER Corp. All Rights Reserved UNIPOWER Telecom, Division of UNIPOWER
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationSurge Protective Devices Installation, Operation and Maintenance Manual. ServiceTrack ST Series: 080, 120, 160, 200, 240, 300 and 400
ServiceTrack ST Series: 080, 120, 160, 200, 240, 300 and 400 Surge Protective Devices Installation, Operation and Maintenance Manual TEL: 800-853-8265 www.innosyspower.com SERVICETRACK ST INSTALLATION,
More informationExplosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter
Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2
More informationInstallation Guide for America Solar Wholesale Photovoltaic Modules
Installation Guide for America Solar Wholesale Photovoltaic Modules Mono Module Poly Module 1 ASW Photovoltaic Module Installation Guide Installation guide for American Solar Wholesale Photovoltaic modules
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationUser's Guide. Model High Precision Quad Output DC Power Supply
User's Guide Model 382270 High Precision Quad Output DC Power Supply Introduction Congratulations on your purchase of the Extech 382270 DC Power Supply. The Model 382270 can be used for many applications
More informationHP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.
HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationLine reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4
Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA
More informationDVI Detective. User Manual EXT-DVI-EDIDN. Release A3
DVI Detective EXT-DVI-EDIDN User Manual Release A3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use
More informationDigital Lighting Systems, Inc.
, Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual
More informationOPLC Installation Guide
Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs
More informationDemo Kit Quick Start Guide
Near Field Imaging (NFI) Projected Capacitive Touch Screen Systems Read and understand all safety information contained in this document before using this product. Introduction This is intended to help
More informationAltivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216
Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationDifferential Liquid/Gas Pressure Transmitter
Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with
More informationPMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A
PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849
More informationModel 2657A-LIM-3 LO Interconnect Module
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect
More informationSurge Protective Devices. STV100K Series. Instruction Manual
Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage
More informationSurge Protective Devices. STV100K Series. Instruction Manual
Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage
More informationIRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE
O P E R A T I N G I N S T R U C T I O N S IRB-RET UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L 3 2 5-2 0 1 6 M O N I T O R E D DEVICE 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216
More informationSUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.
SUN2000-100KTL-USH0 Quick Guide Issue: 01 Part Number: 31509347 Date: 2018-02-08 HUAWEI TECHNOLOGIES CO., LTD. NOTICE The information in this document is subject to change without notice. Every effort
More informationChore-Tronics Mobile Server
Chore-Tronics Mobile Server Installation & Operator s Instruction Manual Contact your nearby Chore-Time distributor or representative for additional parts and information. Chore-Time Group A division of
More informationPlease read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation
Please read these instructions carefully before installing This will ensure an easy start and a great first customer experience with TS4 installation INTERACTIVE INSTALLATION AND SAFETY MANUAL FOR TS4:
More informationInstalling and Configuring Rialto Analytic Appliances
Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation
More informationInstallation, Operation and Maintenance Manual
Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
More informationDual Link DVI Extender
2x Dual Link DVI Extender EXT-2DVI-CATDL User Manual Release A4 2x Dual Link DVI Extender Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4.
More informationIO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs
IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The
More informationiconverter 2-Module Power Chassis
iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by
More information4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!
4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.
More information