UT75A / UT55A / UT52A / UT35A / UT32A

Size: px
Start display at page:

Download "UT75A / UT55A / UT52A / UT35A / UT32A"

Transcription

1 Digital Indicating Controller UTAdvanced Digital Indicating Controller UT7A / UTA / UTA / UTA / UTA Program Controller UPA / UPA / UPA Digital Indicator with Alarms UMA Bulletin PA-EN

2 Reliable and secure Welcome the new members: The UPA, the UTA dual loop and the DIN rail models. UPA Program Controller UPA UPA NEW UT7A UTA UTA UTA UTA Digital Controller NEW NEW NEW UTA/MDL UTA/MDL DIN Rail Mounted Controller UTA-D (Dual-loop type) UTA/MDL UTA/MDL DIN Rail Mounted Controller UMA Digital Indicator with Alarms Configuration and Programming Software LLA

3 Make your equipment easy to use Clearly see what your process is doing A variety of functions, for easy connectivity Useful ladder sequence control Reliability RoHS/WEEE NEMA*/IP66 Front Panel * Hose down test only. 76 CSA C. 6- UL6- CE marking conformance available soon with the /MDL option. NEW Space saving options /th DIN -loop controller (UTA-D) CC-Link communication available in a x mm (/ DIN) size /th DIN Program controller (UPA) DIN rail Mounted controller (/MDL option) More UPA program patterns 99 program patterns (/AP option)

4 Make your equipment easy to use Setting and managing parameters Easily edit settings from a PC while the unit is mounted in the control panel. Settings are accessed through a dedicated adapter on the front panel. Ethernet-equipped controllers can be programmed remotely. Control panel Set up parameters Controller data read/write/compare Data management Print parameters and data; create reports Configure user defaults Set up right out of the box To USB port No power required LLA Configuration Software Optical communication adapter and programming cable Programming cable * With DIN rail mounted controllers, power is required. Free software is available on the web for converting GREEN series parameters to UTAdvanced. To USB port A single unit supports multiple applications Universal Input and Output Supports different sensors, heaters, and actuators TC mv V ma RTD -wire transmitter to ma current Voltage pulse Relay contact Motor operated valve* *Select a position proportional model for motorized valve control output. Universal Inputs Universal Control Outputs Easily reset to your original settings The user default function allow you to recover from operator mistakes. Set your user default values with the LLA configuration tool. Scrolling text makes menu navigation easy If critical parameter values are accidently changed and can not be easily identified, the user default can restore them to the original values with a few button strokes. Save space in the control panel Side-by-side close mounting on DIN rails in the panel Status indicator (LED) Green:Normal Red: Abnormal Ambient temperature: - to C ( to C with CC-Link installed) DIN rail -loop control in a single unit (UTA-D/MDL) UTA/MDL UTA/MDL UTA-D/MDL

5 Clearly see what your process is doing Bright & Easy to Read Active Color LCD Display Full size PV display (text height:. mm) digit display segment display UTA / DIN ( mm)size UTA / DIN ( mm)size Active Color PV Display See the status of your process conditions INSTANTLY! Normal Display color changes! Navigation guides and keys make it easy to operate Navigation guide will tell you what key can be pressed next Alarm Alarms Deviation values Measured values Contact input Choice of fixed white or red One-touch operation Programmable Function Keys You can assign frequently used operations (start/stop, remote/local, etc.) and parameter entries (PID value, etc.) to function keys for one-touch operation. Navigation Guide Navigation Keys Move freely (up/down/left/right) between parameters! UT series

6 A variety of functions, for easy connectivity Connect to PLCs without programming! Communication protocol DeviceNet PLC Open Network Recipe management Remote monitoring You can easily set setpoints (SP), PID, and alarms from a PLC. Modbus/TCP Modbus RTU/ASCII Serial gateway function Modbus slave Ladder communication PC-Link UTAdvanced with RS- communication Space-saving built-in CC-Link models UTA, UTA, UMA, UTA/MDL, UTA/MDL Modbus/TCP FA-MV PLC SMARTDAC+ GX/GX Modbus TCP, a protocol that allows the controller to connect to Ethernet network and have the ability to exchange data with the computers or devices on that network. Ethernet Ethernet-serial Gateway Function RS- Gateway function allows RS- Modbus devices to communicate via Ethernet. Physical layer: BASE-T/ BASE-TX Max. number of connection : UTAdvanced with RS- communication Peer to Peer The use of the ladder sequence program makes it possible to exchange analog data and status data between communication-capable UTs. Example: A UT in which an input error occurs sends a signal to another UT to enable that UT switch to MAN operation, thus shifting the whole system into a safe mode. In such a case, the safety mechanism can be built into the UTAdvanced and is not required in the host system. Coordinated operation Coordinated operation: This function syncs operation of the slave with that of the master through Yokogawa's proprietary communication protocol. Finely adjust the temperature setting of the slave with the bias and ratio PLC or other device not needed for tuning No programming means fewer engineering manhours * Create ladder sequence programs by the LLA Parameter Setting software (sold separately). RS RS- Continuous furnace Slave UTA Slave UTA Master UPA Zone Zone Zone Up to master units, total units SP is zone SP minus C SP is zone SP plus C SP is programmed 6

7 Useful ladder sequence control Easily adapts to the customer's requirements Using the UTAdvanced's ladder sequence control offers a low-cost alternative for applications typically dependent on PLCs, timers, and relays. It saves wiring time and space. The ladder sequence control allows us to meet the ever changing needs of our customers. * Requires parameter setting software (sold separately). Less wiring PLC Timer Relay Sudden specification changes? Benefits You can recreate the operation of timers and relays in the controller's ladder programs. Lower cost Fewer instruments Less wiring Saves space Highly flexible Example: Alarm annunciator lamp routine Desired operation Lamp blinks on a new alarm Lamp is on solid when the active alarm is acknowledged Lamp goes out when alarm clears Acknowledge alarms with function keys Time Chart Alarm status (AL.ST) Lamp output Alarm occurs Alarm occurs Blinks Turns off Blinks Turns on Acknowledgment button operation Acknowledgment Acknowledgment Alarm Ladder Sequence Program AL.ST SET RST Acknowledgment button M -sec flag AL.ST M M M Lamp output Example: On delay timer Desired operation Hold down the F key for sec. or longer to turn relay ON Release F key to turn relay OFF Time Chart F key Relay s. Program F_KEY TIM TIM CLK TIM K Y_AL 7

8 Product Line-up Size (W x H x D) Weight DIN rail mountable (no display/keys) Input sampling period (control scan period) PV input Number of analog inputs Aux. analog input PV input indication accuracy Number of analog outputs PV input type Control output type Control output Retransmission output Retransmission output (aux. output) Standard Number of digital inputs Maximum Standard Number of digital outputs Maximum Communication Number of SP groups Number of PID groups Number of alarm groups Number of ladder steps Number of ladder instructions Standard Number of program patterns Max. (option) Standard Total number of segments Max. (option) Power supply Power consumption (at V AC) Screw terminal size V DC loop power supply Heater burnout alarm Dust and waterproof level of front panel RoHS/WEEE UT7A 6mm 6mm 6mm g or less No Yes (option),, ms ms : : Dual-loop type (max.) (max.) (max.) (non-isolated) ±. % of F.S. TC : K, J, T, B, S, R, N, E, L, U, W, PL-, PR-, W97Re-W7Re RTD : JPt, Pt ma : to ma, to ma mv, V : to V, to V, to V,. to V, - to mv, to mv (max. ) (only with control output) Relay output : Contact rating (VAC, A or VDC, A)Normally open, point (Heating/cooling output in UTA/UTA) Current output : to ma, to ma, to ma, to ma Voltage pulse output 9 RS Ethernet CC-Link PROFIBUS-DP DeviceNet 6 Basic instruction : Application instruction : No VA UTA UTA UTA to ma, to ma, to ma, to ma 9 RS CC-Link Basic instruction : Application instruction : 7 -VAC or VAC VA M. Yes (option) Yes (option) Excludes DIN rail mounting types NEMA*/IP66 Front Panel Excludes DIN rail mounting types Compliant 7 RS Ethernet CC-Link PROFIBUS-DP DeviceNet VA Safety and EMC standards GS (General Specifications) GS PB-EN 76 CSA C. 6- UL6- GS PC-EN GS PC-EN * CE marking certification available soon with the /MDL option. GS PD-EN GS PD-EN

9 UTA 6mm Yes (option) ms UTA-D UPA UPA UPA, ms 6mm g or less No ms 6mm UMA 6mm,, ms (non-isolated) (max.) ±. % of F.S. TC : K, J, T, B, S, R, N, E, L, U, W, PL-, PR-, W97Re-W7Re RTD : JPt, Pt ma : to ma, to ma mv, V : to V, to V, to V,. to V, - to mv, to mv (max. ) (max. ) (only with control output) (only with control output) Relay output : Contact rating (VAC, A or VDC, A) Normally open (UTA-D) Normally open, point (Heating/cooling output in UPA) Current output : to ma, to ma, to ma, to ma Voltage pulse output to ma, to ma, to ma, to ma to ma, to ma, to ma, to ma 9 RS CC-Link Yes (option) VA RS Yes (option) Yes (option) Excludes DIN rail mounting types RS Ethernet CC-Link PROFIBUS-DP DeviceNet Basic instruction : Application instruction : VAC or VAC VA M. No Yes (option) NEMA*/IP66 Front Panel Excludes DIN rail mounting types Compliant RS CC-Link VA 9 RS CC-Link Yes (option) No GS PD-EN GS PD-EN GS PD-EN GS PD-EN 76 CSA C. 6- UL6- GS PC-EN GS PD-EN * CE marking certification available soon with the /MDL option. GS PD-EN 9

10 Product Line-up Digital Indicating Controller UTA/UTA (Standard model) Main Features Up to analog inputs available alarm relays with independent common terminals steps of ladder logic control Simple operation Up to DOs (various combinations available) External Dimensions UTA UTA Unit: mm UTA - Type : - Basic control - Type :Functions Type : Display language (*) /DR /LP /HA Digital Indicating Controller (Power supply - V AC)(provided with retransmission output or V DC loop power supply, DIs, and DOs) Position proportional type Heating/cooling type Remote ( additional aux. analog) input, 6 additional DIs, additional DOs, (*) (*) and RS- communication (Max. 9. kbps, -wire/-wire) Remote ( additional aux. analog) input, additional DI, and RS- communication (Max. 9. kbps, -wire/-wire) (*) additional DIs and additional DOs Remote ( additional aux. analog) input and additional DI Remote ( additional aux. analog) input, 6 additional Dls, and additional DOs additional DIs, and additional DOs (*) additional aux. analog inputs and additional DIs RS- communication (Max.. kbps, -wire/-wire) Ethernet communication (with serial gateway function) CC-Link communication (with Modbus master function) PROFIBUS-DP communication (with Modbus master function) DeviceNet communication (with Modbus master function) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always - Additional direct input (TC &, -wire/-wire RTD) and current to Remote ( additional aux. analog) input, DI to be deleted (*) V DC loop power supply (*) Heater break alarm (*6) Power supply V AC Coating (*7) *: When the Type is or 6, only can be specified for the Type. *: When the /LP option is specified, the RS- communication of the Type or is -wire system. *: English, German, French, and Spanish are available for the guide display. *: The /DR option can be specified when the Type is any of,,,, or 7. *: The /LP option can be specified in the combination of Type (any of,,, or ) and Type (any of or ). Additionally the /LP option can be specified in the combination of Type and Type. *6: The /HA option can be specified only when the Type is -. *7: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with to mm (panel thickness) Terminal cover UTA - Type : - Basic control - Type : Functions Type : - Display language (*) /DR /LP /HA Digital Indicating Controller (Power supply - V AC)(provided with retransmission output or V DC loop power supply, DIs, and DOs) Position proportional type Heating/cooling type Remote ( additional aux. analog) input, additional DI, and RS- commuication (Max.. kbps, -wire ) Remote ( additional aux. analog) input and additional DI additional DIs, and additional DOs CC-Link communication (with Modbus master function) (*) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always - Additional direct input (TC & -wire/-wire RTD) and current to Remote ( additional aux. analog) input, DI to be deleted (*) V DC loop power supply (*) Heater break alarm (*) Power supply V AC Coating (*6) *: The Type can be specified only when the Type is - and the Type is. *: English, German, French, and Spanish are available for the guide display. *: The /DR option can be specified only when the Type is and the Type is. *: The /LP option can be specified only when the Type is - or -. Furthermore both Type and Type s should be. *: The /HA option can be specified only when the Type is - and the Type is. *6: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with Application examples Cascade control RTD Primary PV input to ma DC Cooling water return UTA Secondary PV input Flow meter Cooling water Industrial furnace temperature control Position proportional control for actuator motor Furnace temperature Position feedback slide wire UTA Controlling temperature in an industrial furnaces by modulating an actuator with a position proportional output. Either current ( - ma) or resistance feedback can also be used for the position signal. Motor drive On/Off outputs Control motor Hot air

11 Digital Indicating Controller UTA/UTA (Standard model) Main Features target setpoints and PID sets available alarm relays with independent common terminals steps of ladder logic control Simple operation Up to DOs (various combinations available) External Dimensions UTA 6 UTA to mm (panel thickness) Terminal cover (option) Unit: mm UTA - Type : - Basic control - Type :Functions Type : Display language (*) *: English, German, French, and Spanish are available for the guide display. *: The /LP option can be specified in the combination of Type (any of "" or "") and Type (any of "" or "".) *: The /HA option can be specified only when the Type is "-" or "-." *: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with UTA - - Type : - Basic control -V -C -R Type :Functions Type : Display language (*) /LP /HA /CV /RSP /LP /HA /CV /RSP Digital Indicating Controller (Power supply: - V AC)(provided with retransmission output or V DC loop power supply, DIs, and DOs) Position proportional type Heating/cooling type additional DIs, additional DOs additional DIs, additional DOs RS- communication (Max.. kbps, -wire/-wire) Ethernet communication (with serial gateway function) CC-Link communication (with Modbus master function) PROFIBUS-DP communication (with Modbus master function) DeviceNet communication (with Modbus master function) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always "-" V DC loop power supply (*) Heater break alarm (*) Power supply V AC Coating (*) Terminal cover Non-isolated remote input (please see the General Specifications GS PD-EN.) Digital Indicating Controller (Power supply: - V AC) (provided with retransmission output or V DC loop power supply, DIs, and DOs) Position proportional type Heating/cooling type UTA Digital Indicating Controller (Entry model) (please see the General Specification GS PF-EN.) RS- communication (Max.. kbps, -wire/-wire) (*) additional DIs and additional DOs CC-Link communication (with Modbus master function) (*) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always "-" V DC loop power supply (*) Heater break alarm (*) Power supply V AC Coating (*6) Terminal cover Non-isolated remote input (please see the General Specifications GS PD-EN.) *: When the /LP option is specified, the RS- communication of the Type is -wire system. *: The type can be specified only when the Type is - and the Type is. *: English, German, French, and Spanish are available for the guide display. *: The /LP option can be specified in the combination of Type (any of "-" or "-"), Type (any of "" or "") and Type. *: The /HA option can be specified in the combination of Type "-" or "-." and Type. *6: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with Application examples Electric furnace Recorder SMARTDAC+ GX/GX Modbus communication Thermocouple to ma DC UTA Alarms Heating/cooling control Cooling water Cooling (relay signal) Heating ( to ma DC) SCR Thyristor UTA Electric furnace SCR Thyristor Thermocouple Heating unit

12 Product Line-up DIN Rail Mounted Controller External Dimensions UTA/UTA (with option /MDL) 6 DIN rail TH-7A Unit: mm Main Features DIN rail mounting Tidy appearance Up to analog inputs available alarm relays with independent common terminals steps of ladder logic control Comes with a wealth of functions. UTA/UTA (with option /MDL) DIN rail TH-7A.. UTA/UTA: terminal cover comes standard UTA/UTA: terminal cover sold separately UTA Type : - Basic control - /MDL (Required) Type : Functions 7 Type : - - /MDL (Required) /LP DIN Rail Mounted Controller (Power supply - V AC) (provided with retransmission output or V DC loop power supply, DIs, and DOs) (without the display parts and keys) Heating/cooling type Remote ( additional aux. analog) input, additional DI, and RS- communication (Max.9. kpbs, -wire or -wire/-wire) (*) additional DIs and additional DOs Remote ( additional aux. analog) input and additional DI Remote ( additional aux. analog) input, 6 additional Dls, and additional DOs additional aux. analog inputs and additional DIs RS- communication (Max.. kbps, -wire/-wire) Ethernet communication (with serial gateway function) CC-Link communication (with Modbus master function) PROFIBUS-DP communication (with Modbus master function) DeviceNet communication (with Modbus master function) Temperature unit: deg C & deg F Always - Mount on DIN rail (without the display parts and keys) (*) V DC loop power supply (*) Power supply V AC Coating (*) *: When the /LP option is specified, the RS- communication of the Type is -wire system. *: The /MDL option and /LP option can be specified in the combination of Type (any of,,, or ) and Type. *: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with UTA Type : Basic control Type : Functions Type : /MDL (Required) DIN Rail Mounted Controller (Power supply - V AC) (provided with retransmission output or V DC loop power supply, DIs, and DOs) (without the display parts and keys) Remote ( additional aux. analog) input, additional DI, and RS- commuication (Max.. kbps, -wire ) CC-Link communication (with Modbus master function) Temperature unit: deg C & deg F Always - /MDL Mount on DIN rail (without the display parts and keys) (*) (Required) Power supply V AC Coating (*) *: When the /MDL option is specified, the model and the s are as follows: UTA---/x/MDL UTA---/x/MDL *: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with UTA /MDL (Required) Type : - Basic control - Type : Functions Type : - - /MDL (Required) /LP /CV DIN Rail Mounted Controller (Power supply: - V AC) (provided with retransmission output or V DC loop power supply, DIs, and DOs)(without the display parts and keys) Heating/cooling type additional DIs, additional DOs RS- communication (Max.. kbps, -wire/-wire) Ethernet communication (with serial gateway function) CC-Link communication (with Modbus master function) PROFIBUS-DP communication (with Modbus master function) DeviceNet communication (with Modbus master function) Temperature unit: deg C & deg F Always "-" Mount on DIN rail (without the display parts and keys) (*) V DC loop power supply (*) Power supply V AC Coating (*) Terminal cover *: The /MDL option and /LP option can be specified in the combination of Type and Type. *: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with UTA /MDL (Required) DIN Rail Mounted Controller (Power supply: - V AC) (provided with retransmission output or V DC loop power supply, DIs, and DOs) (without the display parts and keys) Heating/cooling type RS- communication (Max.. kbps, -wire/-wire) (*) CC-Link communication (with Modbus master function) Temperature unit: deg C & deg F Always "-" Type : - Basic control - Type : Functions Type : - - /MDL (Required) Mount on DIN rail (without the display parts and keys) /LP V DC loop power supply (*) /HA Heater break alarm (*) Power supply V AC Coating (*) /CV Terminal cover *: When /LP option is specified, the RS- communication of the type is -wire system. *: The /MDL option is specified, the model and s are follows: UTA---/x/MDL UTA---/x/MDL UTA---/x/MDL *: When /MDL option and /LP option is combined, can not be specified for Type. *: The /HA option can be specified only in the combination of Type "" and Type. *: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with (*) (*)

13 Dual-loop Controller UTA-D External Dimensions UTA-D 6 Terminal cover (option) Unit: mm Main Features Dual-loop control Space-saving Simple operation Ladder sequence programs can be built alarms available as standard UTA-D (with option /MDL) to mm (panel thickness) 6 DIN rail TH-7A.. Panel mounting UTA Type : -D Basic control Type :Functions Type : - - Display language (*) /HA /CV Digital Indicating Controller (Power supply: - V AC) (provided with DIs and DOs) Dual-loop type RS- communication (Max.. kbps, -wire/-wire) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always "-" Heater break alarm (*) Power supply V AC Coating (*) Terminal cover *: English, German, French, and Spanish are available for the guide display. *: The /HA option can be specified when the Type is "." *: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with DIN rail mounting UTA /MDL (Required) Type : -D Basic control Type :Functions Type : - - /MDL (Required) /CV DIN Rail Mounted Controller (Power supply: - V AC) (provided with DIs, and DOs) (without the display parts and keys) Dual-loop type RS- communication (Max.. kbps, -wire/-wire) Temperature unit: deg C & deg F Always "-" Mount on DIN rail (without the display parts and keys) Power supply V AC Coating (*) Terminal cover *: When the option is specified, the UTA does not conform to the safety standards (UL and CSA) and CE marking (Products with Application examples Incubator control Heat source Chamber Spray UTA-D Water Control of reflow furnaces Reflow furnaces NO. Reflow furnaces NO. Remote SP RS UTA-D UTA-D Hatch eggs right on schedule by controlling both temperature and humidity

14 Product Line-up Digital Indicating Controller UT7A External Dimensions UT7A Terminal cover Unit: mm UT7A - Type : - Basic control - Type :Functions Type : Display language (*) /CP Digital Indicating Controller (provided with retransmission output or V DC loop power supply, DIs, and DOs) (Power supply - V AC) Position proportional type Dual-loop type additional DIs and additional DOs Remote ( additional aux. analog) input, RS communication (Max.9. kbps, -wire), additional DI, and additional DOs Remote ( additional aux. analog) inputs, RS communication (Max.9. kbps, -wire), additional DIs Remote ( additional aux. analog) input, 6 additional DIs, additional DOs (*) RS- communication (Max.. kbps, -wire/-wire) and additional DIs Ethernet communication (with serial gateway function) CC-Link communication (with Modbus master function) PROFIBUS-DP communication (with Modbus master function) DeviceNet communication (with Modbus master function) English (Default. Can be switched to Spanish by the setting.) German (Customized order) French (Customized order) Spanish (Default. Can be switched to English by the setting.) White (Light gray) Always - Power supply V AC Carbon potential calculation function (*) Coating (*) to mm (panel thickness) *: When Type is -, cannot be specified for Type. *: English and Spanish are available for the guide display. (German and French guide displays are customized. Contact our representatives for inquiries.) *: Only when Type is, or, the /CP option can be specified. *: When the option is specified, the UT7A does not conform to the safety standards (UL and CSA) and CE marking (Products with Enhancing Productivity by Managing a Variety of Recipes Switch between setpoint conditions Program pattern operation Easy to switch between recipes with a PLC Quality Up Product A furnace Product B Yield Up Thyristor SCR UT7A Up to SPs (target setpoints) Up to 6 PID values Product C Product E Product D Product F Program pattern consists of up to segments -loop program pattern can be operated Loop Loop SCR SCR Device Temperature Loop program pattern Program patterns can be created using loops Loop program pattern Time Since CC-Link, Profibus, and DeviceNet are supported, it is easy to link to a PLC that manages recipes Time A host device (PLC, etc.) manages multiple recipes (SPs and program patterns). Transfer SPs, PID values, and program patterns to the UT7A. Easy batch setting Time A sequence is run according to the transferred program pattern. Application examples -loops of control with a single controller -loop synchronous and independent operation The start and stop instructions can be run synchronously or independently. Program pattern operation and single setpoint operation are available for -loop control A sequence can be run by combining the program pattern on one loop and a fixed setpoint on the other. Temperature/humidity control Dry-bulb temperature Wet-bulb temperature SCR Positioner Steam Requires arithmetic instruction of ladder programs. A variety of arithmetic instructions and large capacity ladder programs basic instructions and application instructions Ladder program capacity up to, steps CP control Furnace temperature (TC) (O sensor) Thermocouple Partial pressure of O (mv) O sensor Accomplished by a ladder program CP calculation (CpCalc) Partial pressure of CO Constant value CP value PID -ma relay voltage pulse -ma CP value (analog transmission) Atmosphere control Square root, exponential, and logarithmic calculations are available Temperature/humidity and carbon potential calculations are available Furnace wall CP control Temperature O sensor O Carrier gas UT7A Reference air Temperature %C GX recorder Control valve Enriched gas Proportional valve Dilution air Control valve

15 Program Controller UPA (Standard model) Main Features Up to 99 program patterns PV events, 6 time events, and alarms can be monitored simultaneously Ladder sequence programs can be built Simple operation Up to 9 DIs and DOs (combinations available) External Dimensions UPA (.7) 6 Terminal cover 9.6 to mm(panel thickness) 9.6. Unit: mm UPA - Type : - Basic control - Type :Functions Type : Display language (*) /AP /DR /HA Program Controller (Power supply: - V AC) program patterns / program segments (99 program patterns / 6 program segments when the option /AP is specifed. Max. 99 segments per pattern)(provided with retransmission output or V DC loop power supply, DIs, and DOs) Position proportional type Heating/cooling type Remote ( additional aux. analog) input, additional DI RS- communication (Max.9. kpbs, -wire/-wire) additional DOs (*) additional aux. analog inputs, DIs and DOs to be deleted RS- communication (Max.. kbps, -wire/-wire) Ethernet communication (with serial gateway function) CC-Link communication (with Modbus master function) PROFIBUS-DP communication (with Modbus master function) DeviceNet communication (with Modbus master function) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always - 69 additional patterns/ additional segments Additional direct input (TC and -wire/-wire RTD) and current input to Remote ( additional aux. analog) input, DI to be deleted (*) Heater break alarm (*) Power supply V AC Coating (*) *: When the Type is, only can be specified for the Type. *: English, German, French, and Spanish are available for the guide display. *: The /DR option can be specified only when the Type is or. *: The /HA option can be specified only when the Type is -. *: When the option is specified, the UPA does not conform to the safety standards (UL and CSA) and CE marking (Products with Program Controller UPA/UPA (Standard model) Main Features Up to program patterns PV events, time events, and alarms can be monitored simultaneously. Ladder sequence programs can be built Simple operation Up to DIs and DOs (combinations available) External Dimensions UPA UPA UPA UPA 6 to mm (panel thickness) Unit: mm Terminal cover (option) *: English, German, French, and Spanish are available for the guide display. *: The /HA option can be specified only when the Type is "-" or "-." *: When the option is specified, the UPA does not conform to the safety standards (UL and CSA) and CE marking (Products with *: Type can be specified only when both Type and Type are. *: English, German, French, and Spanish are available for the guide display. *: The /HA option can be specified only when the Type is - or - and Type is. *: When the option is specified, the UPA does not conform to the safety standards (UL and CSA) and CE marking (Products with UPA Type : Basic control Type : Functions Type : Display language (*) UPA - Type : - Basic control - Type :Functions Type : Display language (*) /AP /HA /CV /AP /HA /CV Program Controller (Power supply: - V AC) program patterns/ program segments (When the /AP option is specified, program patterns/ program segments, max. segments per pattern.) (provided with retransmission output or V DC loop power supply, DIs, and DOs) Position proportional type Heating/cooling type additional DIs, additional DOs RS- communication (Max.. kbps, -wire/-wire) Ethernet communication (with serial gateway function) CC-Link communication (with Modbus master function) PROFIBUS-DP communication (with Modbus master function) DeviceNet communication (with Modbus master function) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always - additional patterns/ additional segments Heater break alarm (*) Power supply V AC Coating (*) Terminal Cover Program Controller (Power supply: - V AC) program patterns/ program segments (When the /AP option is specified, program patterns/ program segments, max. segments per pattern.) (provided with retransmission output or V DC loop power supply, DIs, and DOs) Position proportional type Heating/cooling type RS- communication (Max.. kbps, -wire/-wire) additional DIs, additional DOs CC-Link communication (with Modbus master function) (*) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) Always - additional patterns/ additional segments Heater break alarm (*) Power supply V AC Coating (*) Terminal Cover

16 Product Line-up Digital Indicator with Alarms UMA Main Features Up to 9 alarm outputs (including one Fail) Input correction (linearization) (PV bias, polygonal line approximation, polygonal line bias) VDC sensor power supply available Simple operation CC-Link communication support External Dimensions UMA Unit: mm Terminal cover UMA Type :Basic - Type :Functions Type : Display language (*) /LP /CV Digital Indicator with Alarms (Power supply: - V AC) (provided with retransmission output or V DC loop power supply, DIs, and DOs) additional DO (c-contact relay), RS- communication (Max.. kbps, -wire/-wire) (*) additional DO (c-contact relay) 6 additional DOs (c-contact relay; point and open collector; points) CC-Link communication (with Modbus master function) (*) English (Default. Can be switched to other language by the setting.) German (Default. Can be switched to other language by the setting.) French (Default. Can be switched to other language by the setting.) Spanish (Default. Can be switched to other language by the setting.) White (Light gray) V DC loop power supply (*) Power supply V AC Coating (*) Terminal cover *: When /LP option is specified, the RS- communication of the Type is -wire system. *: Type can be specified only when the Type is or. *: English, German, French, and Spanish are available for the guide display. *: The /LP option can be specified only when the for Type is any of, or, and the Type is. *: When the option is specified, the UMA does not conform to the safety standards (UL and CSA) and CE marking (Products with 6 to (panel thickness) digits, -segment large LCD display with PV color changing function You can set the display to change colors during alarms. Active Color PV Display Normal Alarm LLA Parameter Setting Software Parameter setting display LLA Program pattern creating display - Parameter Setting Software with Ladder Program Building Function Tuning display Ladder program building display Network profile creating display 6

17 Main Features SUPER Function suppresses overshoot SUPER The field-proven SUPER function utilizes a built-in "expert" operator and fuzzy logic to deliver fine control and suppress overshoot. When needing to suppress overshoot When needing to reduce the startup time When load changes are significant When setpoint is changed frequently Temperature SUPER:off Temperature SUPER:on SUPER:on SUPER:on Time Time Time Startup Program operation Disturbance Temperature SUPER Function suppresses hunting SUPER The new SUPER function utilizes a modern control algorithm to deliver fine control and suppress hunting. With frequent load fluctuations With frequent external disturbances that take time to normalize When hunting still occurs after setpoint (SP) changes even if PID constants are tuned Effect : Material change or load change with the same PID. When SUPER function is not used When SUPER function is used PV SP PV PV Effect : Setpoint (SP) change with the same PID. When SUPER function is not used When SUPER function is used PV PV Operation with load causes PV hunting Control using SP with the set PID. Changing SP causes hunting. Control using SP with the set PID. SUPER function suppresses hunting even if SP is changed. Time Time Time Time Auto-Tuning (AT) Function Autotuning is a function that evaluates process characteristics to automatically sets optimal PID values relative to a target setpoint. To implement autotuning, you can configure the following conditions. Two algorithms to calculate PID constants are available. Normal: Fast-rising PID constant Stable: Slow-rising PID constant High and low output limits can be set for control output values during AT runtime. Message Function Using the message function and turning the contact input on/off, a message can be shown on PV display. The message is registered using LLA Parameter Setting Software. The messages are limited to alphanumeric characters. A maximum of four messages can be registered. Operation Display Quick Setting Function Minimum parameters necessary for operation can be set on the initial power up. Security Function The password function can prevent inadvertent changes to the parameter settings. If a password is set, the password is required when accessing to the Setup menu. When the password is verified, Setup Parameters can be changed. CLOSE VALVE When the contact input is turned on, the scrolling message is displayed on PV Display. Battery Free Memory Backup Nonvolatile memory is used for memory parameters backup. Service life is improved because no batteries, backup capacitors, or other components are used. 7

18 Related Instruments Temperature Controller UT Series mm (/6DIN) mm (/6DIN) General Specifications: GS CE-E Lowers equipment costs mm (/DIN) mm (/DIN) Small unit, large display Easy to use auto tune A wide variety of options including communications, alarms, and heater burnout alarms. UT Output signal (for heating) (*) Output signal for cooling Options Suffix -R -V N R V /AL /HBA /RS /V Temperature controller Relay contact output (for time-proportional PID or on/off control) Voltage pulse output (for time-proportional PID) No cooling output () Relay contact output (for time-proportional PID) Voltage pulse output (for time-proportional PID) Alarm outputs ( points) (*) Heater burnout alarm and other alarm outputs (includes the functions of /AL) (*)(*)(*) Communication function (*) Power Supply VDC/VAC *: /AL cannot be specified when specifying /HBA. *: /HBA and /RS cannot be specified at the same time when selecting heating/cooling type. *: Sensor of heater burnout alarm is CTL-6-S or CTL--S6- (URD Co., Ltd., Japan) To be purchased separately UT UT UT Output signal (for heating) (*) Output signal for cooling Options Suffix -R -V -A N R V A /AL /HBA /EX /RET /RS /V Temperature controller Relay contact output (for time-proportional PID or on/off control) Voltage pulse output (for time-proportional PID) to ma output (for continuous PID) (*) No cooling output () Relay contact output (for time-proportional PID control) Voltage pulse output (for time-proportional PID) to ma output (for continuous PID) Alarm outputs ( points) (*) Heater burnout alarm and other alarm outputs (includes the functions of /AL) (*)(*)(*)(*6)(*7) Switchover between SP and SP, and starting of timer by external contacts (*)(*6) to ma retransmission output of measured value (PV) (*)(*) Communication function (*)(*6) Power Supply VDC/VAC *: /HBA can not be specified when selecting. -A: to ma output. *: /AL can not be specified when /HBA is specified. *: /HBA and /RET cannot be specified at the same time when selecting standard type. *: /EX and /RS cannot be specified at the same time when selecting standard type. *: /RET cannot be specified when selecting heating/cooling type. *6: /HBA, /EX and /RS cannot be specified at the same time when selecting heating / cooling type. *7: Sensor of heater burnout alarm is CTL-6-S or CTL--S6- (URD Co., Ltd., Japan) To be purchased separately Program Temperature Controller Simple, -pattern (6 segments) program Comes standard with events A variety of options including communications, retransmission, and digital inputs. General Specifications: GS CF-E Pattern control for small devices mm (/6DIN) UP Output signal Options Suffix -R -V -A N Manual Setter UD Series /EX /RET /RS /V *: /RS option and /EX option cannot be specified at the same time. Program Temperature controller Relay contact output(for time-proportional PID or on/off control) Voltage pulse output (for time-proportional PID) to ma output (for continuous PID) Always N Two digital inputs for RUN/RESET and HOLD/CANCEL (*) to ma retransmission output of measured value (PV) Communication function (*) Power Supply VDC/VAC Instead of remote settings and volume UD UD UD Option Suffix - /V Manual Setter ( mm) Manual Setter ( mm) Manual Setter ( mm) Power Supply V DC / V AC mm (/6DIN) General Specifications: GS FF-E mm (/DIN) mm (/DIN) One-touch adjustment of manual output ( - ma DC) Includes a measured value display, comes standard with alarm outputs Comes standard with a retransmission output that transmits the measurement input as current ( - madc).

19 Data Logging Software GA Monitors and records data from a variety of networked instruments Broad support for data loggers, recorders, digital indicating controllers, signal conditioners, power monitors, and power meters. Even acquires data from Modbus devices. GA Ethernet, serial GM MX MW DA GX GP µr DR DX MV CX UT PR/UPM JUXTA WT Modbus Devices Software DAQLOGGER DAQPlus MXLOGGER Specifications (Overview) Max. connectable units: Max. recording tags (channels): Max. recording MATH tags (channels): Data Logger Recorder Control Instruments Max connectable clients: Unlimited (verified with ) Scan interval: ms or higher (using PC time), or scan interval of instruments (using instrument time) Power Meter General Specifications: GS L6B-E Paperless Recorder SMARTDAC+GX/GX Read/write measured data on other instruments via Modbus protocol. Modbus RTU (RS-A/ connection) Modbus master The data of slave units can be displayed and saved on the GX/GP using the Modbus RTU function*. * Communication function option is required. RS- Cover color (/BC option) UTAdvanced series controller Power meter (Up to 6 slaves can be connected.) General Specifications: GS LB-E RSC/RS Converter ML The ML is a socket type converter with ports (RS-C and RS-) that performs isolation of communication signals, level conversion, and active control of drivers. Built-in RS- line termination resistance of Ω (optional) Select auto or manual RS- driver active control Change communication speeds from to bps in stages with a rotary switch Echo-back ON/OFF switch (-wire types only) Switch between -wire and -wire on the RS- side ML General Specifications: GS 77JL-E 9

20 Find us on your favorite search engine UTAdvanced Search Download user's manuals and specification documents here STEP STEP UTAdvanced Y-Link Search Choose a document type Find answers to the most frequently asked questions. FAQ : vigilantplant, UTAdvanced and SMARTDAC+ are registered trademarks of Yokogawa Electric Corporation. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Other company names and product names appearing in this document are registered trademarks or trademarks of their respective holders. NOTICE Before operating the product, read the user's manual thoroughly for proper and safe operation. If this product is for use with a system requiring safeguards that directly involve personnel safety, please contact the Yokogawa sales offices. YOKOGAWA ELECTRIC CORPORATION Control Instruments Business Division/Phone: ()---779, Fax: () ns@cs.jp.yokogawa.com YOKOGAWA CORPORATION OF AMERICA Phone: --, Fax: () YOKOGAWA EUROPE B.V. Phone: ()--6, Fax: ()--6 YOKOGAWA ENGINEERING ASIA PTE. LTD. Phone: (6)-699, Fax: (6)-666 Sign up for our free newsletter Vig-RS-6E Printed in Japan, (KP) [Ed : /b] Subject to change without notice. All Rights Reserved, Copyright, Yokogawa Electric Corporation.

Full Control at Your Finger Tips

Full Control at Your Finger Tips Full Control at Your Finger Tips Digital Indicating Controllers UT55A/UT52A/UT35A/UT32A Program Controllers UP55A/UP35A Digital Indicator with Alarms UM33A Bulletin 05P01A01-01EN www.utadvanced.com INTRODUCING

More information

PXR Series Advanced Self-Tuning Temperature and Process Controllers

PXR Series Advanced Self-Tuning Temperature and Process Controllers PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater

More information

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere!   Toll Free Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard

More information

/8 DIN Motorized Valve Controller

/8 DIN Motorized Valve Controller Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Indicators. Product Mounting Display Height Page

Indicators. Product Mounting Display Height Page Product Mounting Display Height Page EZ-ZONE PM 1 /32, 1 /16, 1 /8, 1 /4 DIN front panel Upper/Left: 0.30 to 0.80 in. (8 to 20 mm) Lower/Right: 0.22 to 0.50 in. (6 to 13 mm) 379 EZ-ZONE RUI and Gateway

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning

More information

Integrated Multi-Function

Integrated Multi-Function The panel mount controller offers control options that reduce system complexity and thermal loop ownership cost. It can be ordered as a PID controller, an over/under limit controller or its functions can

More information

Eurotherm advanced controllers providing solutions for simple to demanding applications...

Eurotherm advanced controllers providing solutions for simple to demanding applications... Eurotherm advanced controllers providing solutions for simple to demanding applications......with unique levels of control and flexibility Eurotherm 2604-2704 Unique Levels of Flexibility Setpoint Programmer

More information

deltadue series DIN rail mounting modules for control and data acquisition

deltadue series DIN rail mounting modules for control and data acquisition DIN EN ISO 9001 : 2000 QA-Nr.: 041002000292 deltadue series DIN rail mounting modules for control and data acquisition S E R I E S Process controllers Temperature controllers Transmitters with alarms I/O

More information

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview Overview The is a universal input, panel mount remote digital display for process instrumentation. Benefits Easy setup and programming via front panel buttons or remotely using RD software Display readable

More information

Temperature/Process Controllers Manual

Temperature/Process Controllers Manual 3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features

More information

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions. Drawings SD PD-EN Model A Digital Indicating Controller (A-NNN-xx-xx/x) [Style: S] External Dimensions Unit: mm (approx. inch) 96 (.78) (.) 6 (.6) Bracket Terminal cover (.79) 96 (.78) 9.6 (.6) 9.6 (.7).

More information

MLC 9000 Bus Compatible PID

MLC 9000 Bus Compatible PID MLC 9000 Bus Compatible PID Modbus, DeviceNet, Profibus Compatable The MLC 9000 is a unique, stand alone PID control solution to use instead of discrete DIN controllers. Reduce Wiring Costs Clean up the

More information

Universal Process Controller

Universal Process Controller Data Sheet SS/_9 Universal Process ontroller Single output, Heat/ool or Motorized Valve control one controller for every PID control application 9 program, segment Ramp/Soak comprehensive set point profiling

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

MODCELL 2050R Single Loop Controllers

MODCELL 2050R Single Loop Controllers Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile

More information

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN IntesisBox HS-RC-MBS-1 v.0.1 Modbus RTU (EIA-485) Interface for Hisense air conditioners. Compatible with commercial line of air conditioners commercialized by Hisense. User Manual Issue Date: 12/2017

More information

Radically Increase the Performance of Multipoint Temperature Control with the EJ1.

Radically Increase the Performance of Multipoint Temperature Control with the EJ1. N E W Modular Temperature Controllers Radically Increase the Performance of Multipoint Temperature Control with the EJ1. EJ1 Achieve Optimum Temperature Control for a Device. The EJ1 is a new type of Modular

More information

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 11/06 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

DCP250. Controller Programmer Presentation

DCP250. Controller Programmer Presentation DCP250 Controller Programmer Presentation DCP250 Overview Controller and Programmer with Graphic Display 1/4 DIN (96x96mm) size One or two control loops Programmer (255 segments shared in up to 64 programs)

More information

The CAL range of temperature controllers

The CAL range of temperature controllers The CAL range of temperature controllers CAL Temperature Controllers Auto-tuning P.I.D. Controllers with RS232/485 Communication, Charting and Logging Software The CAL range of temperature controllers

More information

ProVU 4 Advanced Temperature & Process Controller

ProVU 4 Advanced Temperature & Process Controller ProVU 4 Advanced Temperature & Process Controller 1/4 DIN Format Graphical / text LCD Display (red/green) Profiling option Datalogging option (data, alarms & events) 5 language (English, French, German,

More information

ControlIT Process controller

ControlIT Process controller Data Sheet ControlIT Process controller CP/CT single-loop temperature controllers CP4, CP8, CT16, CT32: small formats, large display 1 control loop, for simple control tasks to be installed on aggregates

More information

EZ-ZONE PM PANEL MOUNT CONTROLLER

EZ-ZONE PM PANEL MOUNT CONTROLLER EZ-ZONE PM PANEL MOUNT CONTROLLER EZ-ZONE PM Controllers Take the Pain Out of Meeting Your Thermal Loop Requirements The EZ-ZONE PM panel mount controller from Watlow offers control options to reduce system

More information

UDC 3500 FEATURES AND BENEFITS

UDC 3500 FEATURES AND BENEFITS UDC 3500 FEATURES AND BENEFITS The following is a summary of the key features and advantages of the UDC3500. It is important to recognize that these features are meaningless unless they provide an advantage

More information

Max. I/O units. consumption

Max. I/O units. consumption CJ2-Series CPU Units Modular PLC H236 Fast and Powerful CPUs for Any Task All CPU s support IEC61131-3 Structured text, Sequential Function Charts and ladder library helps to reduce your programming effort,

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

Web-enabled DAQ System

Web-enabled DAQ System 2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

Compact data logger offering best-in-class noise resistance and communication function

Compact data logger offering best-in-class noise resistance and communication function T M Portable Data Station XL100 Series Compact data logger offering best-in-class noise resistance and communication function A world s first in measuring instruments! To obtain IPv6 Ready Logo Phase-1

More information

Redundant System Redundant System P9-1-1

Redundant System Redundant System P9-1-1 .. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

Universal power supply

Universal power supply Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 5/03 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers,

More information

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description ProVU 4 Advanced Temperature Controller ¼ DIN Format Graphical / text LCD Display (red/green) Profiling option Datalogging option (data, alarms & events) 5 language (English, French, German, Italian, Spanish)

More information

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal

More information

Instruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E

Instruction Manual. Model US1000 Digital Indicating Controller. IM 5D1A01-01E 3rd Edition IM 5D1A01-01E Instruction Manual Model US1000 Digital Indicating Controller 3rd Edition Introduction This instruction manual describes the general operation of the US1000 Digital Indicating Controller. Intended Readers

More information

FY Series Digital PID Controller Operation Manual FY400 FY700 FY800 FY900 FY600

FY Series Digital PID Controller Operation Manual FY400 FY700 FY800 FY900 FY600 FY Series Digital PID Controller Operation Manual FY101 90X90mm FY100 15X110mm FY400 FY00 FY800 FY900 FY600 48x48mm 2X2mm 48X96mm 96X96mm 96X48mm (DIN 1/) (DIN 3/) (DIN 1/8) (DIN 1/4) (DIN 1/8) February,

More information

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1. Data Sheet 705000 Page 1/12 JUMO mtron T Measuring, Control, and Automation System Com1 RS422/485 oder RS232, Modbus Master/Slave Com2 RS422/485 oder RS232, Modbus Master/Slave oder PROFIBUS-DP Slave LAN

More information

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3. Line A Inverse parallel scrs Load a Line B FUSION SCR POWER O delta CONTROLLERS Line c inverse parallel scrs Load C FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC or DC Output AC Models: 50-1200

More information

BMS Steam Station Solutions

BMS Steam Station Solutions BMS Steam Station Solutions rtk@circor.com www.circorenergy.com Compact Programmable Controller Touch Screen Operator Panel MP-02 CPU Modem / Router Remote management using a SMARTphone Remote management

More information

PRATHAM Embedded solutions

PRATHAM Embedded solutions PROD DUCT INFO ORMA ATION Contact Address : S.NO 256 PLOT NO -14 KH E-mail : HESEPARK LOHEGAON P embedded.pratham@gm PUNE-411032 TEL: 020-26 mail.com 683279 / 9422523598 1 FLOW INDICATING TOTALISER CUM

More information

Built-in features Built-in simplicity Built for fans & pumps

Built-in features Built-in simplicity Built for fans & pumps GE Built-in features Built-in simplicity Built for fans & pumps AF-600 FP Fan & Pump Drives imagination at work Built for variable torque Specifically designed for fan and pump applications, the AF-600

More information

UDC1200 & UDC1700 Universal Digital Controllers Series Micro-Pro Specifications

UDC1200 & UDC1700 Universal Digital Controllers Series Micro-Pro Specifications UDC1200 & UDC1700 Universal Digital Controllers Series Micro-Pro Specifications 51-52-03-35 June 2011 Overview The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN controllers, which combine

More information

ATR121 Controller with Dual Setpoint

ATR121 Controller with Dual Setpoint ATR121 Controller with Dual Setpoint Food industry Ovens/furnaces Refrigeration Sterilizers Environmental chambers Safety units Injection moulding Driers General Specifications Dimensions Supply Voltage

More information

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy The new EZ-ZONE ST integrated control loop solid state controller from Watlow offers complete thermal

More information

1040 DIN Rail Multiple Loop Temperature & Process Controller DIN Rail Multiple Loop Temperature & Process Controller

1040 DIN Rail Multiple Loop Temperature & Process Controller DIN Rail Multiple Loop Temperature & Process Controller 1040 DIN Rail Multiple Loop Temperature & Process Controller Chromalox TM 1040 DIN Rail Multiple Loop Temperature & Process Controller End the Compromise Between the Need for Performance and the Need for

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

Multi-Channel SCR Power Controller Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems

Multi-Channel SCR Power Controller Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems Multi Channel Power Control Suitable to communicate with PLC & Multiloop Dedicated to solve applications Space & wiring reduction Most popular Field Bus available CE EMC and cul listed Elimination of power

More information

C160 Wall-/Pipe Mounted Universal Process Indicator

C160 Wall-/Pipe Mounted Universal Process Indicator Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise The MLC 9000+ compact multi-loop controller... MLC 9000+...ends the control or integration compromise Why the MLC 9000+? Use the MLC 9000+ as a discrete controller mounted behi either as a stand-alone

More information

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1) COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER No.KTC3E2 2006.08 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual. For this product

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy SPECIFICATION SHEET

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy SPECIFICATION SHEET EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST 75 ampere configuration SPECIFICATION SHEET EZ-ZONE ST 40 ampere full configuration with mechanical

More information

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS Line A Inverse parallel scrs Load a Line B COMPACT SCR POWER CONTROLLERS O delta Line c inverse parallel scrs Load C 1 Compact Brochure Rev 3.51 www.ccipower.com 1-800-765-2799 FEATURES Auto-Ranging Input

More information

Omega and Red Lion team-up!

Omega and Red Lion team-up! Omega and Red Lion team-up! Red Lion History Started in 1972 Sensors and OEM Products Panel Meters started in 1976 Red Lion Today 3 International Sales Offices Over 100,000 Square Feet Full Surface Mount

More information

Distributed Multi-Channel Controller DMC10

Distributed Multi-Channel Controller DMC10 No. CP SS 1767E DigitroniK Distributed Multi-Channel Controller DMC10 The DigitroniK DMC10 is a module type 2 or 4-channel compact digital controller. Inputs are full multiple, supporting thermocouple,

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

Compact Controller M CC-M

Compact Controller M CC-M Fuji Instrumentation & Control Fuji Digital Controller Compact Controller M ECNO:1127a FUJI Electric declares a multi-loop controller era The Compact Controller M is a multi-loop controller of a new era

More information

PLC PL User Manual

PLC PL User Manual PLC PL - 300 User Manual Contents list 1. Data acquisition module PL300... 3 1.1 Introduction... 3 1.2 Frontal panel... 5 1.3 Size and installation... 6 1.4 Electrical wirings... 7 1.4.1 Examples of sensors

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta TAC Xenta TAC Xenta 101-VF 3-Speed Fan Coil Controller TAC Xenta 101-VF is a zone controller intended primarily for fan coil applications with the ability to control fans with multiple speeds, with one

More information

E5_C-T Programmable Temperature Controller (Digital Controller)

E5_C-T Programmable Temperature Controller (Digital Controller) N E W E5_C-T Programmable Temperature Controller (Digital Controller) Easy-to-read, simple and dependable Program control»» Set Up to 8 Programs with 32 Segments Each. High-contrast display» Easy set-up

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

01C06/05. Programmable Controller. TomaHawk 8635A. Key benefits. Typical applications for system control

01C06/05. Programmable Controller. TomaHawk 8635A. Key benefits. Typical applications for system control 01C06/05 Programmable Controller TomaHawk 8635A Typical applications for system control Engines, motors, pumps Well control Compressor control Generator set control Small scale automation Typical applications

More information

General Specifications

General Specifications General Model I/O Module (for N-IO) GS 32P06K30-01EN GENERAL This General (GS) provides the hardware specifications of I/O module (for N-IO) that can be mounted on the Base Plate for N-IO I/O (S2BN1D,

More information

Temperature and Process

Temperature and Process Product Control/Limit Loops Mounting Profiling Maximum Output Communication Protocols EZ-ZONE RM 152/192 DIN-rail 15A Standard Bus, EtherNet/IP, DeviceNet, PROFIBUS DP, Modbus TCP, Modbus RTU EZ-ZONE ST

More information

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters Edition November 2003 Information Sheet T 6000 EN Proportional valves e/p Converters Type 6 66 626

More information

SR Mini HG SYSTEM. FAREX SR Mini HG SYSTEM. General Description. Features. Up to 320 control loops* 2 in one system. Flexible installation

SR Mini HG SYSTEM. FAREX SR Mini HG SYSTEM. General Description. Features. Up to 320 control loops* 2 in one system. Flexible installation FAEX S Mini HG SYSTEM S Mini HG SYSTEM General Description The S Mini HG SYSTEM is a DIN-ail mounted multi-loop control system. This product consists of block-type compact modules so that the configuration

More information

General Specifications

General Specifications General Specifications GS 04L65B01-01EN GA10 Data Logging Software Overview Data Logging Software GA10 (hereafter referred to as GA10) is used to collect data from measuring instruments and controllers

More information

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST 75 ampere configuration 40 ampere full configuration with mechanical contactor configuration with only the controller and SSR EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements

More information

Single Loop Controller SDC15

Single Loop Controller SDC15 No. CP SS E Single Loop Controller SDC Features The DigitroniK SDC is a x mm compact digital controller featuring group multi-range inputs and PID control system using new algorithms "Rationaloop PID (Ra-Pid)"

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

EZ-ZONE PM Panel Mount Controller. EZ-ZONE PM Controllers Take the Pain Out of Meeting Your Thermal Loop Requirements SPECIFICATION SHEET

EZ-ZONE PM Panel Mount Controller. EZ-ZONE PM Controllers Take the Pain Out of Meeting Your Thermal Loop Requirements SPECIFICATION SHEET EZ-ZONE PM Controllers Take the Pain Out of Meeting Your Thermal Loop Requirements SPECIFICATION SHEET EZ-ZONE PM Panel Mount Controller The EZ-ZONE PM panel mount controller from Watlow offers control

More information

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE In times where energy conservation is a top priority for all progressive enterprises, the measurement of flow rates and consumption is becoming more and

More information

General Specifications

General Specifications General Specifications GS 04L65B01-01EN GA10 Data Logging Software Overview Data Logging Software GA10 (hereafter referred to as GA10) is used to collect data from measuring instruments and controllers

More information

BACnet Controller for General-purpose Building Applications

BACnet Controller for General-purpose Building Applications Specifications BACnet Controller for General-purpose Building Applications General Model WJ-1101 is the BACnet controller to be used for a wide range of building applications such as air-conditioning and

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

SINGLE-CHANNEL PROCESS INDICATOR series 8001

SINGLE-CHANNEL PROCESS INDICATOR series 8001 SINGLE-CHANNEL PROCESS INDICATOR series 8001 Analog Inputs - all inputs available in one unit - Pt100 RTD type DIN 43 760 or GOST 6651-78 (range from 0 to +600 C) - TC type: J - range from 0 to +600 C

More information

Single Loop Controller Models R35, R36

Single Loop Controller Models R35, R36 Specifications Single Loop Controller Models R35, R36 General Model R35/R36 is a digital indicating controller featuring multi-range inputs and PID control system using new algorithms "RationaLOOP PID

More information

E5CC/E5EC TEMPERATURE CONTROLLER

E5CC/E5EC TEMPERATURE CONTROLLER E5CC/E5EC TEMPERATURE CONTROLLER High performance with simplicity» Unique performance in temperature control» High-contrast display» Easy set-up and operation 2 The new standard in temperature control

More information

Compact Controller M<CC-M>

Compact Controller M<CC-M> Fuji Instrumentation & Control Fuji Digital Controller Compact Controller M ECNO:1127 FUJI Electric declares a multi-loop controller era Compact Controller M is a multi-loop controller of a new era where

More information

Extruder Controls ExtruVision S

Extruder Controls ExtruVision S Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik E2200 Series Smart Ethernet remote I/O with Click&Go Logic Features and Benefits Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Portable Paperless Recorder MV1000/MV2000 www.mv1000.com Bulletin 04Q01A01-01E Measurement scenarios that call for speed

More information

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids Technical Information TI 032D/06/e Nr. 50072927 Flow Computer compart DXF 351 Universal Application for Gas, Steam and Liquids Easy Fast commissioning using Quick Setup and help functions E+H programming

More information

AIAS. Technical description

AIAS. Technical description Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -

More information

Temperature, Process &

Temperature, Process & Temperature, Process & 150 For Temp. Units 1/32 DIN meter 195 with 2 control outputs User Friendly, Simple to Configure High Quality i/32 i/16 i/8 Extended 5-Year Warranty Powerful Features Free Software,

More information

VersaMax Micro and Nano Technical Product Presentation

VersaMax Micro and Nano Technical Product Presentation VersaMax Nano VersaMax Micro VersaMax Micro and Nano Technical Product Presentation Outline Introduction VersaMax Micro and Nano Product Strategy Future Products Product Description VersaMax Nano VersaMax

More information

GF_LOOPER Multiloop Graphic Controller, zones 3.5 and 5.7 screens, TFT, color, touch screen

GF_LOOPER Multiloop Graphic Controller, zones 3.5 and 5.7 screens, TFT, color, touch screen GF_LOOPER ultiloop Graphic Controller, 4-8-12-16 zones 3.5 and 5.7 screens, TFT, color, touch screen ain applications Temperature control of small extruders Thermoformers Temperature control of hot runners

More information

General Specifications

General Specifications General Specifications GS 33K15C20-50E Model LFS1500 Control Function for Field Control Station (for AFV10, Vnet/IP and FIO) Model LFS1550 Node Expansion Package (for AFV10 ) GENERAL Model LFS1500, Control

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information