IQ Range. Keeping the World Flowing. Remote Hand Station. Safe Use and Installation Manual

Size: px
Start display at page:

Download "IQ Range. Keeping the World Flowing. Remote Hand Station. Safe Use and Installation Manual"

Transcription

1 IQ Range Remote Hand Station Safe Use and Installation Manual Keeping the World Flowing

2 Contents Section Page 1 - Introduction Health and Safety Remote Hand Station Mounting Electrical Connections Enabling the Remote Handstation 8 Mode on the IQ3 6 - Remote Hand Station Settings Operating the Remote Hand Station Approvals Environmental 13 2

3 1 - Introduction Actuators used in many industries sometimes have to be mounted in places where it is hazardous, inconvenient or just unpleasant for a human to operate. In these cases it is useful to be able to see the status and locally operate an actuator from a safe distance. Typically in this situation you would be faced with a simplistic interface for basic operation and indication, however Rotork s enhanced solution allows the user to have an exact replication of the actuator interface. Using the same display and controls interface from Rotorks 3 rd generation of IQ actuators, users can remotely operate, interrogate and configure a Rotork actuator from up to 100 m distance. Due to the familiar, feature rich interface, set up couldn t be simpler using the Rotork Bluetooth Setting Tool Pro supplied with the actuator. Retaining the full functionality of the IQ, dataloggers can be viewed and downloaded locally at the Remote Hand Station (RHS) instead of gaining access to the actuator. Power for the RHS is supplied by the actuator, removing the need for supplementary power supplies. The following instructions must be followed and integrated with your safety program when installing and using Rotork Controls products: Read and save all instructions prior to installing, operating and servicing this product. If you don t understand any of the instructions, contact Rotork Controls for clarification. Follow all warnings, cautions and instructions marked on, and supplied with, the product. Inform and educate personnel in the proper installation, operation and maintenance of the product. Install equipment as specified in Rotork Controls installation instructions and per applicable local and national codes. Connect all products to the proper electrical sources. To ensure proper performance, use qualified personnel to install, operate, update and maintain the unit. When replacement parts are required, ensure that the qualified service technician uses replacement parts specified by Rotork Controls. Substitutions may result in fire, electrical shock, other hazards, or improper equipment operation. Keep all product protective covers in place (except when installing, or when maintenance is being performed by qualified personnel), to prevent electrical shock, personal injury or damage to the product. Operation of product in an inappropriate fashion may cause harm or damage to unit or other equipment surroundings. Keeping the World Flowing 3

4 2 - Health and Safety This manual has been produced to enable a competent user to install, operate, adjust and inspect the Remote Hand Station (RHS). The electrical installation, maintenance and use of the RHS should be carried out in accordance with the National Legislation and Statutory Provisions relating to the safe use of this equipment applicable to the site of installation. For the UK: Electricity at Work Regulations 1989 and the guidance given in the applicable edition of the IEE Wiring Regulations should be applied. Also the user should be fully aware of their duties under the Health and Safety at Work Act For the USA: NFPA70, National Electrical Code is applicable. The mechanical installation should be carried out as outlined in this manual and also in accordance with any relevant national standard codes of practice. If the RHS nameplate indicates that it is suitable for use in Potentially Explosive Atmospheres (Hazardous Areas) then the RHS is suitable for use in Zone 1 and Zone 2 (or Div 1 and Div 2) hazardous area classifications, as defined by the RHS's nameplate marking. For Canada: CEC, Canadian Electrical Code is applicable. Any equipment connected to the RHS should be of an equivalent (or better) hazardous area certification. The installation, maintenance and use of the RHS installed in a hazardous area must be carried out by a competent person and in accordance with all relevant codes of practice for the particular Hazardous Area certification. Any inspection or repair of a Hazardous Area approved RHS should not be undertaken unless it conforms to National Legislation and Statutory Provisions relating to the specific Hazardous Area. Only Rotork approved replacement parts should be used. Under no circumstances should any modification or alteration be carried out on the unit, as this could invalidate the conditions under which its certification was granted. Access to live electrical conductors is forbidden in a Hazardous Area unless it is done under a special permit to work, otherwise all power should be isolated and the RHS moved to a non-hazardous area for repair or attention. Only persons competent by virtue of their training or experience should be allowed to install, maintain and repair Rotork equipment. Work undertaken must be carried out in accordance with instructions in the manual. The user and those persons working on this equipment should be familiar with their responsibilities under any statutory provisions relating to the Health and Safety of their workplace. WARNING: Enclosure Materials The RHS is manufactured from aluminium alloy with stainless steel fasteners and terminal enclosure fasteners using 12.9 grade high tensile carbon steel. The cover window is toughened glass which is retained with a 2-part silicone cement. The user must ensure that the operating environment and any materials surrounding the RHS cannot lead to a reduction in the safe use of, or the protection afforded by, the RHS. Where appropriate the user must ensure the RHS is suitably protected against its operating environment. 4

5 3 - Remote Hand Station Mounting Externa Earth Poi The Remote Hand Station (RHS) can be mounted either directly on a wall or to a pole using suitable C brackets. Space should be left around the housing to allow for the fitting of cable glands or conduit. Positioning of the RHS display should be such that easy viewing and operation can be carried out at eye level. Removal of the main display cover is not necessary in order to mount the unit. The only cover that needs to be removed is the terminal housing when cabling to the actuator. 200 The back housing may be mounted in any position (90 o increments) to accommodate different cable / conduit entry requirements. In order to maintain the correct viewing angle of the display, rotate the display cover to suit. NOTE: Maximum Unit Weight = 9 kg 3.1 Locate a suitable place (flat vertical wall or structure) to mount the RHS unit. The display and controls should be accessible and easily viewable. 3.2 Mark up a template using the diagrams above. Use a template to mark the wall or structure. 3.3 Ensure any work permits are obtained before starting work. Prepare the mounting holes using suitable tools. 3.4 Select suitable fixings by referring to the weight above for details of the RHS assembly. 3.5 Install the RHS unit to the structure. Tighten the fixings to ensure a secure hold x 8.5 mm 172 External Earth Point M25 x 1.5p Conduit Entry 200 Keeping the World Flowing 5

6 4 - Electrical Connections The RHS unit is powered by via a CAN Bus system installed within Rotork actuators as an option actuator so does not require any supplementary power supply or protection device. The single cable entry is located at the bottom of the terminal housing and is supplied M25 as standard. A thread adaptor can be supplied for other thread sizes including imperial threads. The interconnecting cable is not supplied. Below is a table of the minimum cable specification for remote mounting up to 50 m and up to 100 m. No. PARAMETER BELDEN CABLE 3084A T5U500 (OR EQUIVALENT) UP TO 100M MINIMUM SPECIFICATION FOR UP TO 50 M 1 Type of Cable Twisted pair shielded Twisted pair shielded 2 No. of Cores 4 (Data pair + Power pair) 4 (Data pair + Power pair) 3 Conductor Material Tinned Copper Tinned Copper 4 Core Insulation Material PVC (power) FPE (data) PVC 5 Shield Type Foil + Braid Braid 6 Shield Coverage Braid 65% Foil = 100% Braid 65% 7 Outer Sheath PVC PVC 8 Data Pair Capacitance 40 pf/m 70 pf/m 9 Conductor Resistance 175 Ohm/km (Power) 280 Ohm/km (Data) 175 Ohm/km 280 Ohm/km (Data) 10 Current Rating 1 A 1 A Note: For installation in hazardous areas suitable equivalent cables must be used in accordance with local regulations. Cable Entry Only appropriately certified flameproof cable glands or conduit may be used in hazardous locations. The cable entry is tapped M25 x 1.5p. In hazardous locations, only one certified flameproof thread adaptor can be used. For installation in USA and Canada Conduit seals must be installed at the enclosure. M25 x 1.5p to either 1 /2", 3 /4", 1", 1 /4" or 1 /2" NPT thread adaptors are factory fitted. CAUTION: Wiring may exceed 70 ºC in a 70 ºC ambient. 6

7 4 - Electrical Connections Please follow the instructions in section 3 for mounting the RHS before attempting to cable up the unit. 4.1 Once the cable specification has been selected, cut to the appropriate length (leaving approx. 200 mm at each end for final termination). 4.2 Feed the cable to both the IQ3 and RHS terminal compartments and secure the glands to ensure watertight integrity is maintained. 4.3 Strip back the insulation and braiding so that the inner twisted pair cores are exposed and fit AMP type ring terminal crimps to each wire and shield braid. Insulate the braid to prevent short circuits. 4.4 Connect the terminals in each compartment to the correct terminal number by following the wiring diagram supplied. Earth Ground Connection A dedicated external earth point is provided for the attachment of a protective earth cable. ACTUATOR TERMINAL BUNG NO. RHS TERMINAL BLOCK NO. FUNCTION Remote Hand Station V (V-CUST) 21 2 GND 32 3 CAN H 50% 40 4 CAN L CLOSE OPEN STOP LOCAL REMOTE 47 5 SHIELD 18 WAY SK1 RHS Bridge Board SK2 Actuator Terminal Block 24V (V-CUST) CAN H CAN SHIELD CAN L GND E This wiring diagram is for reference only, please refer to the specific actuator wiring diagram supplied with the unit. Keeping the World Flowing 7

8 5 - Enabling the Remote Hand Station Mode on the IQ3 NOTE: The following settings are to be carried out at the actuator display only. Settings in section 6 can be carried out at the RHS display. Please refer to the appropriate full configuration manual for your actuator menu structure and PUB (Rotork Bluetooth Setting Tool Pro manual) for instructions on using the Rotork Bluetooth Setting Tool Pro. 5.1 Navigate to the Settings menu Open Limit 5.4 From the Local control menu, navigate to the Remote Hand Station section and highlight Enabled. Stopped Local Control Vandal Disabled Setting Tool Yes No Maintained Yes No Delay Control Yes No Loss Of HMI Stayput Remote Remote Hand Station Enabled On Off 6/6 Press (enter ROTACT as the password). Use or to enable or disable the Remote Hand Station mode. 5.2 From the main list, select Control Once the required mode is checked, press to confirm. The selected mode will be saved and shown as checked on the setting entry. Limits Indication Control ESD Security Defaults Settings 5.3 Next select Local Local Remote Interrupter Timer Control 8

9 6 - Remote Hand Station Settings NOTE: The following settings can be carried out either at the actuator or at the RHS display. Setting the Bluetooth Security - The RHS and actuator Bluetooth security can be configured independently. 6.1 Navigate to SETTINGS > SECURITY and under the Bluetooth section, choose the level of Bluetooth access required for the actuator. Press (enter ROTACT as the password). Use or to select the actuator Bluetooth mode. Once the required mode is highlighted, press to confirm. The selected mode will be saved and shown as checked on the setting entry. Low: Change Lost Code Re-Enter Low: Open Limit Bluetooth Discover Always Password Default L81L18 Remote Hand Station Discover Always 5/5 6.2 Navigate to SETTINGS > SECURITY and under the Remote Hand Station section, choose the level of Bluetooth access required for the RHS. Press (enter the password if applicable). Use or to select the Remote Hand Station Bluetooth mode. Once the required mode is highlighted, press to confirm. The selected mode will be saved and shown as checked on the setting entry. Setting the Action on Loss of RHS control - The actuator action can be configured to a particular mode if the RHS were to fail or lose communication with the actuator. 6.3 Navigate to SETTINGS > CONTROL > REMOTE HAND STATION and under the Remote Hand Station section select the mode on Loss of HMI. Press (enter the password if applicable). Use or to select the Loss of HMI mode. Once the required mode is highlighted, press to confirm. The selected mode will be saved and shown as checked on the setting entry. Open Limit Remote Hand Station Loss of HMI Stayput Local On Off Setting the Local Mode - The Remote Hand Station is intended to work when the actuator is set to Remote Control only, however you can configure the RHS to work when the actuator is set to Local Control. In this case both the RHS and actuator will allow local control, with the last issued command taking preference. 6.4 Navigate to SETTINGS > CONTROL > REMOTE HAND STATION and under the Remote Hand Station section select the Local mode. Press (enter the password if applicable). Use or to select the Local mode on or off. Once the required mode is checked, press to confirm. The selected mode will be saved and shown as checked on the setting entry. Setting the Home Screen Display - The RHS and actuator home screens can be independently configured to show different information. NOTE: The following setting has to be carried out at the device you are configuring, e.g. at the actuator for the actuator home screen and at the RHS for the RHS home screen. 6.5 Navigate to SETTINGS > INDICATION > LOCAL DISPLAY and under the LCD section select the Home Screen mode from the following 4 options: Press Position only Torque (analogue) + Position Torque (digital) + Position Positioner (enter the password if applicable). Use or to select the Local mode on or off. Once the required mode is highlighted, press to confirm. The selected mode will be saved and shown as checked on the setting entry. Home Screen Power Save Close LED Mid Travel LED Alarm LED LCD / LED Test Open Limit LCD Position Torque (A) + POS Torque (D) + POS Positioner On Disabled 1/7 1/2 Keeping the World Flowing 9

10 7 - Operating the Remote Hand Station The Remote Hand Station provides a remote mountable display which allows the operator to monitor and control an actuator mounted in an inaccessible location. All operations which could be performed at the actuator will be duplicated at the Remote Hand Station, including configuration setup, data log download and local control operation. In order to use the RHS for control, the selectors on both the actuator and RHS have to be set according to the table below: Functional operation and setup of the actuator via the RHS mimics the actuator s standard operation, refer to publications PUB (safe use and installation) and PUB (full configuration). The connected actuator s datalogger can be viewed and extracted via the RHS. For datalogger extraction, please refer to the Rotork Bluetooth Setting Tool Pro manual PUB ACTUATOR SELECTORS (HIGH PRIORITY) REMOTE HAND STATION SELECTORS ACTUATOR CONTROL Local Local Actuator* Local Remote Actuator* Remote Local Remote Station Remote Remote Remote control through option cards or hardwired control via terminal block. * Actuator remains in control unless the Local mode is enabled. When Local mode enabled, the RHS shares control despite the actuator set for Local Control. Refer to section

11 8 - Approvals Refer to RHS nameplate for unit specific approval details. European Hazardous Area ATEX (2014/34/EU) II 2 GD Ex db IIB T4 Gb Ex tb IIIC T120 C Db T4, IP66 & IP68 Temperature -20 C to +70 C (-4 F to +158 F) *Option -30 C to +70 C (-22 F to +158 F) Ex db IIC T4 Gb T4 Ex tb IIIC T120 C Db T4, IP66 & IP68 Temperature -20 C to +70 C (-4 F to +158 F) *Option -30 C to +70 C (-22 F to +158 F) International Hazardous Area IECEx. IEC & IEC Ex db IIB T4 Gb Ex tb IIIC T120 C Db T4, IP66 & IP68 Temperature -20 C to +70 C (-4 F to +158 F) *Option -30 C to +70 C (-22 F to +158 F) *Option -50 C to +40 C (- 58 F to +104 F) Ex db IIC T4 Gb T4 Ex tb IIIC T120 C Db T4, IP66 & IP68 Temperature -20 C to +70 C (-4 F to +158 F) *Option -30 C to +70 C (-22 F to +158 F) *Option -50 C to +70 C (-58 F to +158 F) USA Hazardous Area CSAUS - Explosionproof to NEC Article 500 (FM3615 & FM3616) Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F & G FM Explosionproof to NEC Article 500 FM3600, FM3615 & FM3616 Temperature -30 C to +70 C (-22 F to +158 F) Canada Hazardous Area CSA Explosionproof to C22.2 No. 30 CSA Dust explosionproof to C22.2 No. 25 Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F & G Temperature -30 C to +70 C (-22 F to +158 F) Class I, Division 1, Groups B, C & D Class II, Division 1, Groups E, F & G Temperature -30 C to +70 C (-22 F to +158 F) International Non Hazardous Watertight, BS EN60529 IP66 & IP68, (7 metres for 72 hours) Temperature -30 C to +70 C (-22 F to +158 F) US Non Hazardous UL50 Enclosure Type 4x & 6 Temperature -30 C to +70 C (-22 F to +158 F) Canada Non Hazardous Enclosure Type 4x & 6 CSA C22.2 No. 94 Temperature -30 C to +70 C (-22 F to +158 F) Rotork can supply RHS product to national standards not listed above. For details please contact Rotork. Class I, Division 1, Groups B, C & D Class II, Division 1, Groups E, F & G Temperature -30 C to +70 C (-22 F to +158 F) Keeping the World Flowing 11

12 8 - Approvals Maximum Constructional Flamepath Gaps Flamepath Max. Gap (mm) Min. Length (mm) Equipment Type Electrical Cover / Back Housing All Types and Sizes Terminal Cover / Back Housing ATEX / IECEx RHS Terminal Cover / Back Housing for FM & CSA RHS Transfer Loom Bush for FM & CSA RHS Transfer Loom Bush Flamepath RHS ATEX / IEC / CSA / Certified RHS SPECIAL CONDITIONS This Remote Hand Station must only be located in areas where the risk of impact to the viewing window is low. This equipment includes some exterior non-metallic paints including the protective coating. To avoid the possibility of static build up, cleaning must only be carried out with a water dampened cloth. For CAN / CSA C22.2 No compliance the RHS must be connected to a Rotork actuator. THREAD DETAILS FOR ATEX AND IECEx APPROVAL Threaded Flamepath Thread Size Thread Length Equipment Type Cable Entry M25x All Types and Sizes Vibration, Shock and Noise Standard IQ remote hand stations are suitable for applications where vibration and shock severity does not exceed the following: Type Plant induced vibration Shock Seismic Emitted noise Level 1g rms total for all vibration within the frequency range of 10 to 1000 Hz 5g peak acceleration 2g acceleration over a frequency range of 1 to 50 Hz if it is to operate during and after the event Independent tests have shown that at 1m generated noise does not exceed 65 db(a) EXTERNAL ENCLOSURE FASTENERS Enclosure fasteners are stainless steel grade A4-80 M8 for the main display cover and 12.9 M5 for the terminal cover. 12

13 9 - Environmental End user advice on disposal at end of life of the product Subject Definition Remarks / examples Hazardous Recyclable EU Waste Code Disposal Electrical & Electronic Equipment Printed circuit boards Wire All Products All Products Yes Yes Yes Yes Use specialist recyclers Glass Lens/Window IQ No Yes Use specialist recyclers Metals Aluminium Copper/Brass Covers Wire No No Yes Yes Use licensed recyclers Rubber Seals & O-rings Cover Yes No May require special treatment before disposal, use specialist waste disposal companies In all cases check local authority regulation before disposal. Keeping the World Flowing 13

14 Notes 14

15 Notes Keeping the World Flowing 15

16 Keeping the World Flowing A full listing of our worldwide sales and service network is available on our website. Rotork plc Brassmill Lane, Bath, UK tel +44 (0) fax +44 (0) mail@rotork.com Rotork is a corporate member of the Institute of Asset Management PUB Issue 07/17 As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at The name Rotork is a registered trademark. Rotork recognises all registered trademarks. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rotork is under license. Published and produced in the UK by Rotork Controls Limited. POWTG0717

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights.

This installation guide provides instructions for installing the SPARTAN HP Highbay/ Floodlight series of explosion protected floodlights. SPX/SPZ SPARTAN HIGH POWER LUMINAIRE RANGE Installation Guide Zone 1 Variant - CML17ATEX1148 & IEC Ex CML17.0074 Zone 2 Variant - CML17ATEX4149 & IEC Ex CML17.0074 This installation guide provides instructions

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06 PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...

More information

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents

More information

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm)

Skilmatic SI-1Q. Keeping the World Flowing. Spring-Return Electric Quarter-Turn Actuator (65 to 480 Nm) Skilmatic SI intelligent actuators offer a unique combination of the renowned features of Rotork actuation, such as the double-sealing system and non-intrusive infrared commissioning capability, with the

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

CVQ Range. /4 Turn Control Valve Actuator (CVQ) Installation & Maintenance Instructions. Established Leaders in Valve Actuation

CVQ Range. /4 Turn Control Valve Actuator (CVQ) Installation & Maintenance Instructions. Established Leaders in Valve Actuation Electric Actuators and Control Systems Established Leaders in Valve Actuation This Manual contains important safety information. Please ensure it is thoroughly read and understood before installing, operating

More information

CVQ Series. Established Leaders in Actuation Technology. Quarter-turn Control Valve Actuator. Installation & Maintenance Instructions

CVQ Series. Established Leaders in Actuation Technology. Quarter-turn Control Valve Actuator. Installation & Maintenance Instructions CVQ Series Installation & Maintenance Instructions Quarter-turn Control Valve Actuator Established Leaders in Actuation Technology Contents Section Page Introduction 3 General Information 4 Hazardous Area

More information

SolConeX Wall-Mounted Socket, 16 A

SolConeX Wall-Mounted Socket, 16 A SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Rotork Bluetooth Setting Tool Pro

Rotork Bluetooth Setting Tool Pro Rotork Bluetooth Setting Tool Pro Installation Manual Contents Key Functions 2 Introduction 3 Using Insight 2 4 Setting and Editing Missions 6 Bluetooth Device Search Mode 7 Mission Function 8 Extracting

More information

Rotork Fairchild PAX1 Linear Actuator User s Manual

Rotork Fairchild PAX1 Linear Actuator User s Manual Rotork Fairchild PAX1 Linear Actuator User s Manual Product Overview The PAX1 is a flexible low voltage DC powered linear actuator featuring a 5 mm maximum thrust rod stroke moving at speeds up to 0 mm/min

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions Index 1 Optional module 3: Local Interface module... 1 2 Installation... 2 3 Description of OM3 Local Interface... 4 4 To locally operate the actuator... 4 5 OM3 wiring diagram... 5 6 Identification...

More information

CVQ Series. Keeping the World Flowing. Quarter-turn Control Valve Actuator. Installation & Maintenance Instructions

CVQ Series. Keeping the World Flowing. Quarter-turn Control Valve Actuator. Installation & Maintenance Instructions CVQ Series Installation & Maintenance Instructions Quarter-turn Control Valve Actuator Keeping the World Flowing Contents 1.0 Introduction 3 2.0 General Information 4 2.1 Enclosure Materials 4 3.0 Hazardous

More information

3rd Generation Skilmatic SI Range

3rd Generation Skilmatic SI Range 3rd Generation Skilmatic SI Range Spring-Return and Double-Acting Self-Contained Electro-Hydraulic Actuators Keeping the World Flowing Keeping the World Flowing RELIABILITY IN FLOW CONTROL CRITICAL APPLICATIONS

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

CVL Range. Linear Control Valve Actuator (CVL) Installation & Maintenance Instructions. Established Leaders in Valve Actuation

CVL Range. Linear Control Valve Actuator (CVL) Installation & Maintenance Instructions. Established Leaders in Valve Actuation Electric Actuators and Control Systems Established Leaders in Valve Actuation This Manual contains important safety information. Please ensure it is thoroughly read and understood before installing, operating

More information

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth. D460/D470 Series - ATEX certified position transmitter nnnn II 2 GD ITS 11 ATEX 17431X Ex d IIC T* Gb Tamb -*ºC to +*ºC Ex tb IIIC T* Db Tamb -*ºC to +*ºC IP6X Ambient variation -60 C to +110 C (T4/T130

More information

Terminal Boxes Series 8118

Terminal Boxes Series 8118 > Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

Limit Switch Box YT-870/875 SERIES

Limit Switch Box YT-870/875 SERIES Limit Switch Box YT-870/875 SERIES PRODUCT MANUAL VERSION 1.01 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 3 2. Product

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

DR7100 SERIES Supplementary instructions

DR7100 SERIES Supplementary instructions DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

The Solid-State Decoupler (SSD)

The Solid-State Decoupler (SSD) The Solid-State Decoupler (SSD) Installation Instructions Introduction The Solid-State Decoupler (SSD) is a solid-state DC isolation/ac grounding (i.e., coupling) device design ed for use in conjunction

More information

Installation Instruction. HART Add-On Module

Installation Instruction. HART Add-On Module - Translation Typs 17-A1Z0-0005, B7-A2Z0-0033 and G7-A0Z0-0007 Version for: Non hazardous areas ATEX/IECEx Zone 1 and Zone 2 UL Class I Division 1 and Division 2 Document No.: B1-A2Z0-7N0001 / 400570 Revision

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

Power supply unit NG3-16ib

Power supply unit NG3-16ib Ordering Data Designation Type Item no. Power supply unit NG3-16ib (42 V AC / ) 371 008 31 AX Power supply unit NG3-16ib (230 V AC / ) 371 008 32 AX Power supply unit NG3-16ib (100 V AC / ) 371 008 34

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

Page 1 of 5. Increased Safety, Encapsulation and Dust

Page 1 of 5. Increased Safety, Encapsulation and Dust IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex com Certificate No.: Status: Date of Issue: IECEx

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

ELB Detection System. Keeping the World Flowing 1. ELB Product Specification. for Pipeline Monitoring and Valve Control

ELB Detection System. Keeping the World Flowing 1. ELB Product Specification. for Pipeline Monitoring and Valve Control ELB Product Specification General Description Rotork s ELB (Electronic Line Break) is a robust self-contained electronic pipeline monitoring system designed for use in the gas industry. It will continuously

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

EX- Documentation VA 450 / VA 452. thermal mass flow sensor

EX- Documentation VA 450 / VA 452. thermal mass flow sensor EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the

More information

Skilmatic SI 3 Range. Spring-Return and Double-Acting Self-Contained Electro-Hydraulic Actuators. Keeping the World Flowing

Skilmatic SI 3 Range. Spring-Return and Double-Acting Self-Contained Electro-Hydraulic Actuators. Keeping the World Flowing Skilmatic SI 3 Range Spring-Return and Double-Acting Self-Contained Electro-Hydraulic Actuators Keeping the World Flowing Keeping the World Flowing RELIABILITY IN FLOW CONTROL CRITICAL APPLICATIONS RELIABLE

More information

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805

More information

Ex Junction Boxes & Control Stations

Ex Junction Boxes & Control Stations www.fibox.com Ex Junction Boxes & Control Stations Fibox Oy Ab Keilaranta D Espoo, Finland Tel. + () Fax. + () E-mail: info@fibox.fi Homepage: www.fibox.com Fibox Ltd. -, Songdo-Dong, Yeonsu-Gu, Incheon,

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Level-Lance Model 5400A

Level-Lance Model 5400A Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

Metal Position Switch

Metal Position Switch Metal osition Switch Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...2

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

ECE Cert.fic te of Con ormity

ECE Cert.fic te of Con ormity ECE Cert.fic te of Con ormity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex.com Certificate No.:

More information

Skilmatic SI3-3 Electric Fail-Safe Actuators

Skilmatic SI3-3 Electric Fail-Safe Actuators Introducing the 3 rd generation of Skilmatic SI self-contained electric fail-safe actuators. The SI range of self-contained electrohydraulic actuators combining the simplicity of electrical operation with

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

TOCSIN 102C CCTV CAMERA INSTALLATION AND USER INSTRUCTIONS

TOCSIN 102C CCTV CAMERA INSTALLATION AND USER INSTRUCTIONS TOCSIN 102C CCTV CAMERA INSTALLATION AND USER INSTRUCTIONS OLIVER Oliver IGD Limited 4a Pepper Road Stockport SK7 5BW England Tel: Fax: Email: Web Site: IGD +44(0)161 483 1415 +44(0)161 484 2345 sales@oliver-igd.co.uk

More information

DC-D2212R / DC-D2212WR

DC-D2212R / DC-D2212WR Network Camera Quick Guide / DC-D2212WR Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

Instruction Manual. T3110 T3110L T3110Ex

Instruction Manual. T3110 T3110L T3110Ex www.cometsystem.cz Instruction Manual T3110 T3110L T3110Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with 4-20 ma outputs Copyright: COMET System,

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275 NGC-UIT-ORD User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION The nvent RAYCHEM NGC-UIT-ORD is a panel mounted display used in conjunction with other approved

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Modbus Actuator Control

Modbus Actuator Control Modbus Actuator Control Serial communication and control of Rotork actuators Redefining Flow Control Contents Section Page Introduction 3 Modbus Overview 4 Modbus Features Modbus Module 5 RS-485 Communication

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves

Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves Case Study Tank terminal demonstrates the electrically operated solution for Emergency Shutdown Valves Botlek Tank Terminal Case Study - 26th April 2013 Botlek Tank Terminal Case Study - 26th April 2013

More information

Operating Instructions

Operating Instructions Operating Instructions KBDi-DS102W-xxx R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.05 Issue date: 19.09.2018 Disclaimer Disclaimer Publisher and copyright

More information

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006 s SIWAREX JB Aluminum Housing Instruction Manual Edition 03/2006 Table of Contents Table of Contents... 2 Warning and Safety Terms... 3 General... 4 1 Technical Description... 5 1.1 Area of Application...

More information

Velomitor* CT Velocity Transducer

Velomitor* CT Velocity Transducer 190501 Velomitor* CT Velocity Transducer Product Datasheet Bently Nevada* Asset Condition Monitoring Description The Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor

More information

LC2300 Level Controller Installation and Maintenance Instructions

LC2300 Level Controller Installation and Maintenance Instructions 4025350/5 IM-P402-72 AB Issue 5 LC2300 Level Controller Installation and Maintenance Instructions 1 General safety information LC2300 2 General product information 3 Installation >50% >100%

More information

Operating Manual. icam100

Operating Manual. icam100 icam100 This page is intentionally left blank. Document Number 302803 (See Last Page for Revision Details) 2006 Extronics Limited. This document is Copyright Extronics limited. Extronics reserve the right

More information

Minimum cross sectional area of Conductor mm²

Minimum cross sectional area of Conductor mm² Selection Overview Hawke International connectors are ideal for use in hazardous areas commonly found in Oil and Gas exploration, production and process plants. Their features, however, also offer numerous

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...) 7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which

More information

Network Camera. Quick Guide DC-D3C33HRX. Powered by

Network Camera. Quick Guide DC-D3C33HRX. Powered by Network Camera Quick Guide DC-D3C33HRX Powered by Safety Precautions Important Safeguards WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR

More information

Product manual plug, sockets and coupler 16 A.- Z0251

Product manual plug, sockets and coupler 16 A.- Z0251 Product manual plug, sockets and coupler 16 A.- Z0251 INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design UFD 5 Technical Datasheet Display for ALTOSONIC 5 Configurable display for ALTOSONIC 5 Easy installation Durable design KROHNE 04/2015-0.00000.00.00 CONTENTS UFD 5 1 Product features 3 1.1 Local display

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

DeviceNet. Controller Area Network control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems

DeviceNet. Controller Area Network control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems Electric Actuators and Control Systems Established Leaders in Valve Actuation DeviceNet Controller Area Network control of Rotork actuators PUB060-004-00 Issue 05/10 Rotork actuators have been in use all

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Instruction Sheet Board Style Low Water Cutoff

Instruction Sheet Board Style Low Water Cutoff Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

NXCEX-6000 November 2, Series NXC20EX, and NXC40EX Servos for Class 1 Division 2. Hazardous Locations

NXCEX-6000 November 2, Series NXC20EX, and NXC40EX Servos for Class 1 Division 2. Hazardous Locations NXCEX-6000 November 2, 2018 6000 Series NXC20EX, and NXC40EX Servos for Class 1 Division 2. Hazardous Locations Health and Safety SAFETY WARNINGS IN THIS MANUAL In this manual, we indicate potential safety

More information

Operating Instructions Soliswitch FTE20

Operating Instructions Soliswitch FTE20 BA01069F/09/EN/05.15 71307741 Products Solutions Services Operating Instructions Soliswitch FTE20 Point level switch Soliswitch FTE20 Table of contents Table of contents 1 Important document information...

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

IQ SIL Option. IQ actuators for use in applications up to SIL 3. sira CERTIFICATION

IQ SIL Option. IQ actuators for use in applications up to SIL 3. sira CERTIFICATION IQ SIL Option IQ actuators for use in applications up to SIL Keeping the World Flowing RELIABILITY IN FLOW CONTROL CRITICAL APPLICATIONS RELIABLE OPERATION WHEN IT MATTERS Assured reliability for critical

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

and High Temperature Velomitor * System

and High Temperature Velomitor * System 330750 and 330752 High Temperature Velomitor * System Product Datasheet Bently Nevada* Asset Condition Monitoring Description The standard 330500 Velomitor* Piezo-velocity Sensor has a limited temperature

More information