Product Catalogue Ackermann clino system 99

Size: px
Start display at page:

Download "Product Catalogue Ackermann clino system 99"

Transcription

1 Product Catalogue 2007 Ackermann clino system 99

2 Content 1 General Details 2-4 Foreword 2 Abbreviations 2 Alarm Kit for Public Washrooms - 9 System Compact CL 6 System Manual System System Overview clino opt System Description - clino opt Application example clino opt System Overview clino phone System Description - clino phone System Description - System 99 CL 2 System Upgrade from clino phon 9 to System Application example clino opt Central Componets - 0 Duty Room Components 1-7 Room Components 8-7 Additional Components General clino Systems Central Components 80-8 Room Components Additional Components Appendix Index Part number index

3 Foreword You are now holding your own personal copy of our most current Ackermann clino System 99 catalogue for With these solutions, Ackermann clino has once more documented its market-leading innovation skills and with thousands of installations has proven that security, convenience, and protection of investment are economically realisable. See for yourself the many new products and improvements which Ackermann clino has put on the market in the past months and will be introducing shortly. For example: - the new and more cost-effective System Compact CL public washroom alarm kit for disabled washrooms - the new Electronic Modules 99 CLm and CLs with their especially attractive design for the clino System 99 - the Zone Controller 99 CL, optimized for smaller facilities Sant Pau Hospital, Barcelona Bethanien Senior's Home, Solingen Paracelsus Clinic, Zwickau DRK Children's Clinic, Siegen University Clinic, Homburg / Saar Both market and customer orientation as well as competence and innovation are our primary goals. A large number of applicative solutions are available for your individual requirements. One such example: the new intelligent system interfaces to external disciplines such as fire detection technology but also to our proven system clino phon 9. The integration of VoIP/W-LAN for the mobile processing of calls or the connection to emergency call centers has meanwhile become standard for us. Use this opportunity to talk with us and let us know your specific requirements. Your competent marketing consultant will gladly help you with any questions you might have. Looking forward to our cooperative and successful teamwork Your Ackermann clino team Also take at a look at the wide variety of information on our website and register for the customer area. 2

4 Abbreviations = List of contents which the part number includes = Information, important notice such as special versions, dependencies etc. = Packing unit Notice regarding the packing unit: 1. The item will only be sold in packing unit. 2. The number of items, which have to be ordered, always refers to the number of packing unit rather than the number of single items.. The price stated in the catalogue is always the respective price for the packing unit. It is not the price for the single item. Ingress Protection rating Degrees of protection against solid foreign objects indicated by the first characteristic numeral First characteristic brief numeral description: 0 Non-protected 1 Protected against solid foreign objects of 0 mm diameter and greater 2 Protected against solid foreign objects of 12, mm diameter and greater Protected against solid foreign objects of 2, mm diameter and greater 4 Protected against solid foreign objects of 1,0 mm diameter and greater Dust-protected 6 Dust-tight Degrees of protection against liquid foreign objects indicated by the second characteristic numeral Second characteristic brief numeral discription: 0 Non-protected 1 Protected against vertically falling water drops 2 Protected against vertically falling water drops when enclosure tilted up to 1 Protected against spraying water 4 Protected against splashing water Protected against water jets 6 Protected against powerful water jets 7 Protected against the effects of temporary immersion in water 8 Protected against the effects of continuous immersion in water The use of additives (i.e. cleaning agents) can result in deviations to the IP protection classifications given in this catalogue.

5 4

6 1 2 4 Alarm Kit for Public Washrooms System Compact CL 6 System Manual 7 8-9

7 Alarm Kit for Public Washrooms System Compact CL General In order to give disabled people the possibility of calling for help in public washrooms, an emergency call possibility must be installed in these rooms. An initiated call is signalled for example to the doorman or central control employees in this building both optically and acoustically. Thus support for people in need of help is guaranteed. The Alarm Kit for Public Washrooms is the ideal solution for these situations. As a complete system with pull cord, cancel unit and control electronics, as well as a power supply, these components are perfectly tailored to each other. The installation of the Alarm Kit for Public Washrooms is very easy and can be carried out very quickly. Functional Description A call from a disabled person by means of pull cord can be acknowledged by the flashing of an integrated reassurance lamp and a corridor lamp mounted outside of the washroom. The duty room unit installed in the control room or in a break room signals the corresponding staff of the call optically via the flashing of a red control lamp and acoustically via a buzzing signal. The call can be fed into a building / hazard detection system by way of an integrated, floating relay contact. The initiated call can be acknowledged at the duty room unit, i.e. the acoustic signal is temporarily suppressed. The call can be reset only in the washroom by actuation of the cancel push-button. Unlike the clino opt 99 Alarm Kit for Public Washrooms (Part-No C1), the CL series Alarm Kit for Public Washrooms is not expandable! Example of Application: System Compact CL in a public washroom for disabled persons 76910D1 m 1E2s System compact CL The System Compact CL consists of: 1 pull cord with red LED reassurance lamp and 2 m PVC cord, including cover plate, cover plate frames and sealing kit 1 cancel push-button (green) and LED reminder lamp - green, including cover plate and cover plate frames 1 duty room unit with LED control lamp, red, sound generator and acknowledgement push-button, including cover plate and cover plate frames 1 electronic module CL with integrated corridor lamp with LED technology and control electronics as well as a relay contact for controlling of building management system 1 single-phase safety power supply with low-voltage supply fuse 1 operating instructions Input voltage power supply unit 20V / 0Hz Output voltage power supply unit 24V DC / 12W / 0.A Operating temperature power supply unitt max. 0 C Weight electronic module 67g Installation depth electronic module 2mm Colour cover plate / cover frame white - RAL 9016 Dimensions (WxHxD) electronic modules: 71 x 10 x 71mm Dimensions (LxWxH) power supply unit 86 x 41 x 22mm 6

8 Alarm Kit for Public Washrooms System Manual General Information Nurse call systems present an essential factor in washrooms of public buildings and offer disabled people the chance to call for help. Therefore a nurse call system must be installed in such rooms. When a call is actuated, it is either indicated acoustically or visually at the porter s office or at the information desk to guarantee immediate assistance. The easy-to-install alarm kit is the ideal solution for this type of application, as all modules are perfectly tailored to each other and form a stand alone system including pull cord, cancel unit, control electronics and power supply unit. The system can be extended, so that calls can be indicated at diffenrently located indicator units. Operation Manual A call that is actuated from a disabled person by using the pull cord is indicated by a flashing reassurance lamp and by the corridor lamp. The duty room unit, which is installed in the nurse station, porter s room or any other common room, optically indicates the call by means of a red flashing control lamp combined with an acoustic signal (buzzing). The call can be acknowledged at the duty room unit, with the effect that the acoustic signal is temporary withheld. For call cancelling the cancel push-button in the WC must be pressed. If the call is not cancelled, acoustic signalling is automatically reactivated For further extension modules such as the 7004A pull cord, please see page 87. Example of Application: Alarm Kit for Public Washrooms for disabled persons (with accessories) 76910C1 m 1D2n Alarm Kit for public washrooms 1 pull cord with LED reassurance lamp, red - and 2m nylon cord including cover plate, cover plate frame and flush mount backbox 1 cancel button and LED reminder light - green - including cover plate, cover plate frame and flush mount backbox 1 duty room unit for duty rooms with LED control light - red - sound generator and acknowledgement button, including cover plate, cover plate frame and flush mount backbox 1 electronic module with integrated corridor lamp, bulb lamp and system electronics, including installation bracket and flush mounting combination box 1 single-phase safety power supply with low voltage supply fuse Mains voltage 20V AC Nominal frequency 0 to 80Hz Rated current 1A Operating voltage 24V DC Colour pull cord, cancel push-button white, RAL 9016 Compact Call Set housing grey RAL 7040 indicating unit white RAL 9016 plastic base, grey, RAL 7040 white lamp cover, translucent 7

9 Alarm Kit for Public Washrooms 721A7 it 6B8H Zone indicator lamp with 1 lamp cover Zone indicator lamp with 1 neutral lamp cover and 2 lamp cells. Fixation surface mounting Class of protection IP 20 Colour plastic base, grey - RAL 7040 lamp cover, white, translucent PC+ABS - FR lamp cover PC Dimensions (WxHxD) 18 x 110 x 87 mm 7640J2 ja 1K^ Parallel duty room unit The parallel duty room unit serves as an extension module for the alarm kit for public washrooms P Cover plate for parallel duty room unit 88881P yy 2Q4^ Cover plate for parallel duty room unit 1 cancel push-button - white - with symbol 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 8002H t! I4S Small buzzer for call signalling Small buzzer for surface mount installation, 24 V DC. It serves as a signalling device and can be installed in dry and damp rooms. It is a modern encapsulated system, which is suitable for permanent operation. The housing is made of impact-resistant thermoplastic (ABS) - grey -. Rated voltage 24 V DC Sound level approx. 9dB (A) in 1m distance Type of protection IP D i^ 2E8 Relay module for actuating external components Maximum loading capacity 24 V / ampere 18972AV 89899A fm combination box with extruded plaster cover Cover plate for relay module 8

10 Alarm Kit for Public Washrooms 89899A zz :B46 Cover plate for relay module 1 Single dummy cover plate with 2 bore holes. Colour white - RAL 9016 Dimensions (WxH) 90 x 90mm F zu :G4E Cover frame (single) Cover frame (single), suitable for cover plates and intermediate frames (69x69mm). PC+ABS-FR Colour white - RAL 9016 Dimensions (WxHxD) 81 x 81 x 6, mm 9

11 10

12 1 2 4 System 99 System Overview clino opt System Description - clino opt Application Example clino opt System Overview clino phone System Description - clino phone System Description - System 99 CL 2 System Upgrade from clino phon 9 to System Application Example clino opt Central Componets - 0 Duty Room Components 1-7 Room Components 8-7 Additional Components

13 System Overview clino opt

14 System Description - clino opt 99 System Description - clino opt 99 With thousands of installations in different countries both inside and outside Europe, the clino opt 99 nurse call system is firmly established in the market. The system completely complies with DIN VDE 084 Part 1 and Part 2: , and it can be applied in hospitals, nursing homes, residences for handicapped people, rehabilitation clinics or sanatoria. Function The clino opt 99 system is an optical nurse call system, transmitting nurse call information to the nursing staff via corridor lamps, zone indicator lamps, information displays, display modules and when integrated in the system - via SMS to paging and DECT systems. System Layout The clino opt 99 system layout is based on a -level hierarchy. The zone level (ward level) consists of the zone databus, which presents the communication platform for the zone controllers. Thus, calls can be transmitted between zones and wards within the whole system. The next level is the corridor databus and enables communication within the ward. The components connected to the corridor databus are required to link the call devices in each room via the bed databus Zone Databus In the primary level, the zone databus connects a maximum of 16 zone controllers, which in turn are subdivided in three zones. Thereby one clino opt 99 system can consist of 48 zones. Zone Controllers The zone controller is the central control unit which monitors and synchronises the complete bus system and at the same time represents a higher-level connection to further zone controllers. It controls the flashing phases of the corridor and zone indicator lamps, as well as acoustic call signals. Thus, doctor, emergency, normal, remind and telephone calls can be distinguished. Each zone controller supports subzones and has appropriate outputs for zone indicator lamps and telephone lamps, as well as a common malfunction message system. Further inputs allow staff, meal and/or telephone calls to be coupled. Corridor Databus All display and control units of the patient rooms, duty rooms as well as of other monitored rooms and corridors are connected to the corridor databus. The electronic module serves as a room control unit and connects all call devices within the room. Information displays are also operated on the corridor databus. As a whole, a maximum of 127 electronic modules with a maximum of 2 addressable modules such as electronic modules, display modules and call modules can be operated on the corridor databus. Each bus device is allocated its own address allowing individual identification. Electronic Modules The complete electronics required for call identification and call logging are located in the electronic module, which is used as the distribution point for the room wiring. Electronic modules can be used for the whole system. Various variants are available depending on the requirements defined by the customers. There are versions with or 4 lamp sections, or without lamps and versions with and without radio function and bed databus or Presence II. Configuration data are stored in the electronic module s memory module and is, thereby, still available when the electronic module is replaced. For duty rooms, special electronic modules with additional memory for configured zone linking data are used. Bed Databus A maximum of 10 room components such as call modules and display modules are connected to the bed databus. Individual calls actuated directly from the bed can be identified via the address of each call module. Electronic modules without bed databus only allow call modules to be connected as closed-circuit monitored call push-buttons, cancel push-buttons as well as call / cancel push-buttons. Room Equipment Various devices can be installed in the rooms, for example, call modules, call push-buttons, pear push-buttons and pull cords for releasing calls, as well as cancel push-buttons for cancelling calls. Patient handsets can also be installed. In addition to their call function, these enable patients to listen to radio programmes. An auto-release plug mounted on the pear or multiple push-button, as well as on the patient handset, prevents damage of the cord. The information stored in nurse call system with bed databus can be shown on display modules. Existing calls are indicated according to their urgency in plain text. If there are no calls in the system, presences are indicated. System Interfaces Wireless paging or DECT-systems can be connected to the clino opt 99 nurse call system via the paging or DECT interface unit. Thus, existing calls on the nurse call system can be transferred to the staff pocket pager or DECT phone device, indicating type of call, room number and bed identification if available. Additionally, internal signals, such as fire alarms or technical alarms, can be connected via interface units. It is possible to connect the system to an Instabus EIB (European InstBus). Optionally, further third-party devices can be integrated in the system and a call logging PC or a PC provided with a graphic display can be connected via a PC system interface. 1

15 System Description - clino opt 99 System Safety In case of power failure, calls are stored for approximately 24 hours. As soon as the power is switched on again, presences and calls which were set prior to power failure are indicated. In case of a failure occurring in the zone controller, the system operates in an emergency mode, which involves the functions normal and emergency call, cancellation, presence indication and call transfer to rooms where presence has been set, as well as the visual indication on the corridor lamps. The zone controller monitors all active units and displays any malfunctions as a collective message or as individual messages on the information display. The lamp outputs of the electronic modules are short-circuit protected. All electronic modules are fitted with a self-healing fuse. This not only protects the electronic modules but also the equipment in the room. The electrical safety and EMC requirements of all the system components are in accordance with the CE directives. The IP protection classes indicated in the catalogue refer to the completely assembled appliance including cover plate and mounting frames. Maintenance and Service The configuration module is connected to the electronic module via a service socket. The room numbers and, depending on equipment, bed identification are allocated via this module. Additionally the configuration module can be used for service purposes. A zone controller can be exchanged without difficulty. Thus it is possible to access the data stored in the network devices via service functions, so that a quick and easy recovery of the original configuration is possible. Only special parameters have to be newly entered. The electronic modules can be exchanged at any time without interrupting the system operation and can be used and/or exchanged within the entire system in the case of standardized equipment. Voltage supply GND, +24V (+/- 10%) Max. length of zone databus 2000 m (twisted 0.8mm pair of wires) Max. number of zone controllers 16 Max. number of zones per zone controller 48 () Max. number of modules on zone databus 2 (including data interfaces) Max. number per data interface 1 paging-, 1 PC-, 1 printer-, 1 DCF interface Max. length of corridor databus 1000m (twisted 0.8mm pair of wires) Max. number of modules on corridor databus 127 Max. number of duty room on corridor databus 9 Max. number of duty rooms (per zone) Max. number of duty rooms per zone controller 1 Max. length of bed databus 200 m (twisted 0.6mm pair of wires) Max. number of modules on bed databus 10 Max. number of modules on corridor + bed databus 2 Max. number of modules per bed databus 2 display-, 2 speech-, 8 call modules, 4 wall electronic interfaces Max. number of duty room modules 2 display-, 2 speech-, 2 duty selection modules or 1 master station ELA feed in electronic modules 7. V eff., max. 10V eff. input resistance for ELA electronic module 4 KOhm TV sound feed in wall electronics 70mV nominal, max. V input resistance for TV wall electronics 10 kohm Max. switching current for each light button 1 A at 24 V DC Temperature range during operation: 10 to 0 C, rel. humidity 20-80% non-condensing, in storage: 0-60 C, rel. humidity 20-80% non-condensing 14

16 Application example clino opt 99 Nursing Room clino opt

17 Application example clino opt 99 Dialysis Ward clino opt

18 Application example clino opt 99 Linen Store clino opt

19 Application example clino opt 99 Duty Room clino opt

20 Application example clino opt 99 Visitor washroom clino opt

21 Application example clino opt 99 Nursing Home Corridor clino opt

22 Application example clino opt 99 Plant Room - Sub-Distribution clino opt

23 System Overview clino phon

24 System Description - clino phon 99 System Description - clino phon 99 clino phon 99 is the nurse call system with speech from Ackermann clino systems. Just like the smaller nurse call system version clino opt 99, it completely complies with DIN VDE 084 Part 1 and Part 2: The clino phon 99 system can be applied in institutions, which intend to improve the efficiency of their nursing system through speech communication. This might be appropriate in hospitals, nursing homes, residences for handicapped people, rehabilitation clinics or sanatoria. Function clino phon 99 is an optical and acoustical nurse call system with integrated speech communication that enables direct call-back to the patient or the nursing staff depending on who has actuated the call. Thus, time can be efficiently used and further assistance can be asked for if required. In addition, the nursing staff can receive information such as other nurse calls, emergency calls and doctor calls via corridor lamps and room terminals, information displays, display modules and SMS or DECT compatible devices. Besides enabling a speech facility in each room, the system can also be extended by means of direct speech facilities at each bed to allow hands-free or discreet communication. For this purpose, microphones and loudspeakers are provided at the room terminals, bedside electronics and patient handsets System Layout The clino phon 99 system layout is based on a -level hierarchy. The zone level (ward level) consists of the zone databus, which through its fail-safe loop structure offers maximum safety and presents the communication platform for the zone controllers. Thus, calls can be transmitted between zones and wards within the whole system. The next level includes the corridor databus and enables communication within the ward. The components connected to the corridor databus are required to link the call devices in each room via the bed databus. Zone Databus In the primary level, the zone databus connects a maximum of 64 zone controllers, which in turn can be subdivided into six sub-zones. Thereby one clino phon 99 system can be extended to 24 logical zones (sub-zones). Zone Controllers The zone controller is the central control unit which monitors and synchronises the complete bus system and at the same time represents a higher-level connection to further zone controllers. It controls display messages, the flashing phases of the corridor and zone indicator lamps and the acoustic call signalling. Thus, call classifications such as alarm call, emergency call, normal call can be distinguished. There are special signals for calls on hold and telephone calls. Each zone controller supports 6 sub-zones / organisational units and has several configurable inputs and outputs for status registration as well as linking to other third party systems. One speech channel is available for each zone controller. A minimum of one master zone controller, which is designed for setting up communication with the nurse call server responsible for the configuration and programming of the system, is required in the clino phon 99 system. Depending on the requirements, zone controllers are suitable for centralised or decentralised installation. Corridor Databus All display and control units in the patient rooms, duty rooms as well as in other monitored rooms and corridors are connected to the corridor databus. Depending on the type of application, the room control unit either serves as an electronic module for rooms without speech facility or as a room terminal for rooms with speech facility. It is the connection point for all call devices within the room. Information displays are also operated on the corridor databus. As a whole, a maximum of 127 electronic modules or room terminals with a maximum of 2 addressable modules such as room terminals, electronic modules, display modules and call modules can be operated on the corridor databus. Each bus device is allocated its own address allowing individual identification. Room Terminal and Electronic Module The room terminal or electronic module for rooms without speech facility takes over total control of the call functions within the room. This includes not only call identification as well as call logging, but also the presence function with call transfer for the nursing staff. For an efficient care service, the room terminals allow speech communication with patients or residents, as well as between the nursing staff. Answered calls are acknowledged via the function buttons, whereby normal calls, as opposed to emergency or alarm calls, can be remotely terminated. The room electronics also contain all the terminal points for the room wiring. This includes operating components at the bed, in the bathroom, as well as a corridor lamp connected to the room terminal - in the electronic module, the corridor lamp is already integrated. For controlling organisation procedures, the duty room is provided with a master station, which is connected to the clino phon network by means of a duty room interface. Bed Databus A maximum of 10 room components such as bedside electronics including patient handset, call modules and display modules are connected to the bed databus. Individual calls actuated directly from the bed can be identified via the address of each call module. clino phon 99 room terminals as well as electronic modules without bed databus only allow call modules to be connected as closed-circuit monitored call pushbuttons, cancel push-buttons as well as call/cancel push-buttons. 2

25 System Description - clino phon 99 Room Equipment Various devices can be installed in the rooms, for example, call modules, call push-buttons, pear push-buttons and pull cords for releasing calls, as well as cancel push-buttons for cancelling calls. For rooms where discreet communication is required, bed modules in connection with patient handsets can be installed at the patient s bed. In addition to their call and voice communication function, the patient handsets enable patients to switch the light on/off as well as to control radio and TV channels. An auto-release plug mounted on the pear or multiple push-button, as well as on the patient handset, prevents damage of the cord. The information stored in the nurse call system can be shown on room terminals and display modules. Existing calls are indicated according to their urgency in plain text. If there are no calls in the system, presences are indicated. System Interfaces Wireless paging or DECT-systems can be connected to the clino phon 99 nurse call system via the paging or DECT interface unit. Thus, existing calls on the nurse call system can be transferred to the staff pocket pager or DECT phone device, indicating type of call, room number and bed identification if available. Additionally, internal signals, such as fire alarms or technical alarms, can be connected via interface units. It is possible to connect the system to an Instabus EIB (European InstBus). Optionally, further third-party devices can be integrated in the system and a call logging PC or a PC provided with a graphic display can be connected via a PC system interface. System Safety During a power failure, all system messages are stored short-term until a power source (i.e. UPS) takes over the power supply for security purposes in no later than 1 seconds. In this way it can be ensured that all messages can be further processed. On reactivation of the network, presence indicators and calls which were set before the power failure are displayed. In case of a failure occurring in the zone controller, the system operates in an emergency mode, which involves the functions normal and emergency call, cancellation, presence indication and call transfer to rooms where presence has been set, as well as the visual indication of the corridor lamps. The zone controller monitors all active units and displays any malfunctions as a collective message or as individual messages on the information display. The lamp outputs of the electronic modules are short-circuit protected. All electronic modules are fitted with a self-healing fuse. This not only protects the electronic modules but also the equipment in the room. The electrical safety and EMC requirements of all the system components are in accordance with the CE directives. The IP protection classes indicated in the catalogue refer to the completely assembled appliance including cover plate and mounting frames. Maintenance and Service The system is normally configured via the nurse call server. Alternatively, the configuration module can be connected to the room electronics by means of a configuration socket and the room number as well as the bed identification, depending on the configuration, can be programmed. Additionally, the configuration module can be used for service purposes. A zone controller can be replaced without difficulty. Thus it is possible to access the data stored in the network devices via service functions, so that a quick and easy recovery of the original configuration is possible. The room terminals can be exchanged at any time without interrupting the system operation and can be used and/or exchanged within the entire system in the case of standardized equipment. Voltage supply 24 V (+/-10%) Current consumption when defining the current consumption a simultaneity factor of 0.2 is assumed, that is 20 % max. current consumption (i.e. normal call) and 80% min. current consumption (i.e. quiescent current) Max distance between 2 zone controllers 0m / 10m depending on the cable type Max. number of zone controllers 64 Max. number of zones per zone controller 24 (6) Max. length of corridor databus 800 m (twisted 0.8 mm pair of wires) Max. number of duty room on corridor databus 6 Max. number of duty rooms (per zone) 1 Max. length of bed databus 200 m (twisted 0.6 mm pair of wires) Max. number of modules on bed databus 10 Max. number of modules on corridor + bed databus 2 Max. number of modules per bed databus 1 display module, 8 call modules Max. number of duty room modules 1 master station Max. number of modules on corridor databus

26 System Description - System 99 CL With the System 99 CL, Ackermann clino has expanded the current portfolio of the System 99 with a communications solution which is optimally adjusted to the requirements of smaller facilities. Here, special focus is on facilities which do not want to go without the functional range of a clino phon 99 nurse call system having a grade of extension which is also conceived for larger facilities with more than 1000 rooms! The System 99 CL picks up the thread here and embodies the characteristics of speech communication between service and patient rooms, mobile call answering via a mobile terminal device but also the convenient forwarding of system messages within one organisational unit. This concept is thus optimized for a smaller grade of extension. Furthermore, external systems (i.e. DECT message handling systems) are connected to a central control unit especially adjusted to this system and which assumes the tasks of the clino phon 99 operating unit. Moreover, the System 99 CL central control unit takes over the saving of log files, DCF77 radio clock input feed as well as an optional remote servicing access, in order to also be able to externally set-up the System 99 CL. The system configuration is carried out here via LAN using an external PC (i.e. laptop), via which the respective configuration data is read, modified and written back over the System 99 CL central control unit. Thus, use of a costly operating computer is not necessary! Application example With a maximum number of four 99 CL zone controllers, which can each administer up to 0 active units on the corridor databus and a maximum system size of up to 200 active units (room terminals, electronic room modules etc.), the System 99 CL fulfills the requirements for smaller facilities to 100%. If no speech communication is required in patient rooms, the available system components of an Ackermann clino classic nurse call system is complemented with the 99 CLm electronic room module. A completely cost-effective solution! 2

27 System Upgrade from clino phon 9 to System 99 For expansion and retrofitting, Ackermann clino has developed a comprehensive migration concept for the linking of clino phon 9 and System 99. The entire communication system can thus be serviced as one standardized system without output losses - a great relief in daily routine of care-giving. In the course of successive new occupancies of for example a nursing ward after finishing a restructuring or expansion, the existing System clino phon 9 and the newly installed System 99 can be used together. This principle is not only transferable to smaller units but also to entire building complexes. For nursing staff and patients, only the different patient handsets and room terminals indicate two systems. Interconnections on one floor, i.e. in times of reduced operation, can also be carried out using the migration concept independent of the existing systems in the ward without difficulty. Secure migration concept for retrofitting during normal operation: from clino phon 9 to System 99 Special software and hardware modules mediate between the old system and the new in order to enable all functions on both systems simultaneously. For example: system report indication call answering auxiliary answering general announcements (station) freely programmable zone linkage Intelligent interface units guarantee full functionality: innovative loop technology for system linking audio interfaces for the connection of analogue and digital speech functions software modules act as intermediaries between the systems With solutions from Ackermann clino, you receive integration security and flexibility - despite highly complex organizational structures. Just ask us - we can find a solution for your facility and put it into action together. 26

28 Application example clino phon 99 Duty Room

29 Application example clino phon 99 Ward Bathroom clino phon

30 Application example clino phon 99 Common Room clino phon

31 Application example clino phon 99 Patient Room with discreet speech 0

32 Application example clino phon 99 Nursing Room with Bedside Speech Facility clino phon

33 Application example clino phon 99 Resident Room clino phon

34 Application example clino phon 99 Plant Room - Central Installation clino phon

35 Application example clino phon 99 Plant Room - Decentralised Installation clino phon

36 Central Components Controller A ic 1B/ Zone Controller CLx System 99 2 Monitoring and control of entire data traffic as well as speech communication within the zone Data exchange with other zone controllers Integrated Ethernet interface for connection of the CL 99 operating computer Digital audio bus for speech within the ward as well as across zones Service functions: software download, remote maintenance (in conjunction with connected clino phon 99 operating computer) Up to 64 zone controllers within the zone databus Network via POF or HCS cable Up to 6 subzones per zone controller Central or decentral installation Safety characteristics: Data retention for 1 hour in case of power failure 1x relay contact for collective messaging of fault reports within a zone Electrical isolation from other zone controllers through FO cable connection (POF) Socket for optional configuration via a configuration module LED status display as well as LCD with 2 x 8 characters Zone controller as a control unit for an organizational unit such as a ward or a corridor. A maximum of 127 rooms can be operated in up to six subzones. The zone controller monitors and synchronises the entire data traffic within the zone, provides for data exchange between master and slave zone controllers. The zone controller establishes the connection to the operating computer. Protection of signal line IP 20 Installation Colour grey RAL 70 Dimensions (WxHxD) 40 x 00 x 0mm surface mounting or mounting in 19 distribution cabinet Integration into separate connection board with optional surface mounting or in 19 cabinet Connection cable for zone controller 72660Z Z2 Connection board for sm clino phon 99 zone controller Connection board (19 ) for clino phon 99 zone controller 4

37 Central Components 72660C ic 1D9 System 99 CL Zone Controller Zone controller as control unit for an organizational unit as for example ward or living area serves as a basis for system installations in smaller facilities with up to a maximum of 200 active units on the corridor databus. A zone controller monitors and synchronizes all of the data traffic within the zones and provides for the data exchange between zone controllers. A zone controller establishes the connection to the central control unit. monitoring and control of all data traffic as well as of the speech communication within a zone data exchange with other zone controllers integrated Ethernet interface for connection of the CL 99 central control unit digital audio bus for speech within the ward as well as across zones service functions: software download, remote maintenance networking of up to 4 zone controllers networking via POF and/or HCS cable maximum of up to 200 active units on the corridor databus in one System 99 CL (distributed over various zone controllers), 0 per zone controller Safety characteristics: data retention in case of power failure according to DIN VDE x relay contact for collective messaging of fault reports within a zone 4 freely configurable inputs electrically isolated from other zone controllers via POF connection status indicator via LEDs as well as an LCD display with 2 x 8 characters Operating voltage range Rated voltage Current consumption Rated current Ambient temperature range Fixation Weight Dimensions (WxHxD) 21.6 to 26.4 V DC 24V DC 46 ma 24 ma + C to + C (cover) oven enamelled sheet steel surface mounting or installation in 19 distribution cabinet 220 g 40 x 00 x 0 mm Integration into separate connection board with optional surface mounting or in 19 cabinet. Zone controller connector cable Available as of Q Z Z2 Connection board for sm clino phon 99 zone controller Connection board (19 ) for clino phon 99 zone controller 6

38 Central Components 72662A ic B7 System 99 CL Central Control Unit 1 Nurse call system central control unit for the transmission of configurations, logging as well as interfacing to third-party systems such as a paging system or DECT system, among other things. The configuration is carried out via an external PC. 2 minimum configuration: mini-central control unit 2* LAN Ethernet (10/100 MBit) DCF-77 radio clock operating system configuration software system backup software Ackermann clino phon 99 system software CD with application software for the following functions: - clino phon 99 configuration tool - allocation of room configuration - definition of functions and parameters of the nurse call system - set-up of call type, call type groups, call type upgrading - configuration of actuators for control of external systems (i.e. light, blinds) - set-up of radio and TV programs - service functions - database management system for data storage - system management tools for system analysis - network functions for system access - freely configurable services (zone networking) - allocation of temporally defined services - selection of call type groups for services - definition of target-oriented forwarding of messages between nurse call system zones - freely configurable announcement functions (collective announcements) - selection of recipients for collective announcements - fault monitoring and reporting (according to DIN VDE 084) Optional: - message transmission to a wireless messaging system (i.e. paging system -PSAor telecommunication installation -DECT-) - freely configurable recipient addresses for messages from nurse call system zones - definition of the display format of messages to be transmitted - set-up of different services (i.e. day / night service) - allocation of repetition times, acoustic call tones, etc. 4 7

39 Central Components 72660Z1 ic 1[2D Connection board for sm system 99 zone controller Sm connection board for easy installation of zone controllers and connection cables. The connection board must be mounted as a surface mount housing. Cable bars are integrated for structured cabling. Class of protection IP 20 Installation surface mounting Colour grey - RAL 70 Dimensions (WxHxD) 40 x 00 x 0 mm 72660Z2 ic 1[J Connection board (19 ) for system 99 zone controller The connected board is suitable for installation in a 19 distribution cabinet. Cable bars are integrated for structured cabling. Class of protection IP 20 Installation mounting in 19 distribution cabinet Colour grey - RAL 70 Dimensions (WxHxD) 40 x 00 x 0 mm 7281B1 i[ 2C2' Audio-ISDN-Interface clino phon 99 Audio ISDN interface as the audio interface between the System clino phon 99 and a classic telecommunication installation. System messages can be retrieved per mobile terminal device via the telecommunication installation. According to the user configuration, incoming system messages (i.e. calls, emergency calls, alarm calls) are dynamic ally allocated callback numbers. The information is transferred to the telecommunication installation and displayed on the mobile terminal device via message transmission (only in connection with optional software on the operating computer / clino phon 99 central control unit). A callback causes an automatic connection set-up to the displayed system message. Up to 10 multiple subscriber numbers (MSN) are allocated to the audio ISDN interface during configuration. Up to 4 units are incorporated in the System clino phon 99 ward databus as central components. Interfaces - zone databus for digital and audio transmission - ISDN interface for connection to ISDN telecommunication network or telecommunication system or DECT system (Euro-ISDN-Standard (DSS1)) - service jack for connecting analysis tools - service LEDs for fast fault analysis - status and service LEDs Mounting The module is attached to the corresponding connection board and mounted with a quick release. The module is surface-mounted in connection with an installation box. Operating voltage 24 V DC Current consumption 400 ma Class of protection IP 40 Connection length 1000 m Housing PC+ABS - FR Colour wihte, RAL 9016 Weight 171g Dimensions (WxHxD) 17 x 109 x 4 mm 7282Z1 Connection board for duty room interface 8

40 Central Components 72661A ic 2B POF-Cu Converter System 99 / 21 1 POF-Cu converter for active transformation of a POF connection (i.e. System 99 zone controller) to a copper RS422 four-wire connection. Different lengths can be spanned depending on of the type of cable used. 2 Operating voltage 24 V DC Current consumption 100 ma Temperature range 0 to 70 degrees Range max. with cable I-Y(St)Y: 10m, max. with system cable 8974Ax: 20 m, max. with cable CAT: 00 m Fixation top hat rail mounting Dimensions (WxHxD) 40 x 82 x 9 mm B ic 2C8 Converter POF-Cu System 99 / 21 Converter POF-FO for active transformation of a POF connection (i.e. System 99 zone controller) to a 2-wire OWG fiber optic connection. Different lengths can be spanned depending on of the type of cable used. Operating voltage 24 V DC Current consumption 20 ma Temperature range 0 to 70 degrees Weight 20 g Range max. with multimode cable 0/12μ: 1000 m, max. with multimode cable 62./12μ: 2000 m FO - Connector type ST plug Fixation top hat rail mounting Dimensions (WxHxD) 40 x 82 x 9 mm 72661C ic 2D= POF patchcable m POF patch cable for the connection of two ward databus devices (i.e. zone controllers) or for the connection of one device and a converter. 2 pcs 72640A2 ia 1B0 clino opt 99 zone controller (without audio) Zone controller for operating up to 127 rooms with a maximum of three subzones.the zone controller monitors and controls the entire data traffic within the zone and provides for data transfer between zone controllers. In case of power failure, all relevant data is stored for 24 hours. Monitors and synchronises entire data traffic within a zone Data exchange with other zone controllers Actuation of up to zone lamps, telephone lamps One input for telephone connection, meal call and staff call for each subzone Max. of subzones per zone controller Class of protection IP 40 Installation surface mounting or top-hat rail mounting Colour white RAL 9016 Dimensions (WxHxD) 110 x 182 x 4 mm 72640Z1 Connection board for sm clino opt 99 zone controller Safety features: Data retention for 24 hours in case of power failure Relay contact for collective messaging of fault reports within a zone 9

41 Central Components 72640Z1 ia Connection board for sm clino opt 99 zone controller 88899A additional fastening for top-hat rail mounting 72642C ia D= Corridor databus splitter / repeater / terminator - active The corridor databus splitter / repeater enables corridor databus branching and can be used as a repeater for the corridor databus. Class of protection IP 40, when installed incl. according cover plate Installation in flush-mounted backbox, DIN 4907 Dimensions (WxH) 71 x 71 mm For the clino phon 99 system, 2 units are required for each corridor databus: One unit for the databus line and one for the audio line A Cover plate, white RAL A Mounting frame for cover plate (single) 88914B Mounting frame for cover plate (double) 88914C Mounting frame for cover plate (triple) 7269A i` :BM Corridor databus terminator - passive The databus terminator serves as a terminating module with the corresponding impedance for the corridor databus. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Dimensions (WxH) 71 x 71 mm 88910A Cover plate, white RAL A Mounting frame for cover plate (single) 88914B Mounting frame for cover plate (double) 88914C Mounting frame for cover plate (triple) 88910A y 1B4 Cover plate Cover plate with resting snatching attachment suitable for mounting frame. Colour white RAL

42 Central Components System Cables P1 zj Q2A HCS Fiber optic cable,10 m 2 HCS fiber optic cable for the connection of two ward databus devices (room terminals, electronic modules or also zone controllers in System 99), which are installed spatially apart from each other. The HCS fiber transmits all speech and data signals on the ward databus. Data communication Bending radius Cable cross-section 10 Mbit/s min. 100 mm/ mm 4 mm x 7 mm AH zj BI Halogen-free system cable, 00m cable drum Halogen-free system cable (00m cable drum) for power supply, time multiplex and speech transmission, 6-core. Cable Fire load Colour LIY 2 x 1. + I2YV 2 x (2 x 0.6 ST) Y 1200 kj/m green cable sheath Quantity unit: 00m cable drum 8974AJ zj BK% Halogen-free system cable, 100m bundle Halogen-free system cable (100m bundle) for power supply, time multiplex and speech transmission, 6-core. Cable Fire load Colour LIY 2 x 1. + I2YV 2 x (2 x 0.6 ST) Y 1200 kj/m green cable sheath Quantity unit: 100m bundle 41

43 Central Components System contact interface 72641A2 ia 2B4 Contact interface System contact interface unit for system expansion by connecting an existing nurse call system or external systems via floating contacts. Depending on configuration, up to 4 inputs and 4 outputs can be used. In clino phon 99 systems, this interface servers as a control unit for the zone indicator lamps. Class of protection IP 40 Installation surface mounting or top-hat rail mounting Colour white RAL 9016 PC + ABS - FR Dimensions (HxWxD) 182 x 110 x 4 mm 72641Z1 Connection board for contact interface 72641Z1 ia 2[2D Connection board for contact interface 88899A Additional fastening for top-hat rail mounting Serial Interface / 1 for each system (maximum) Class of protection IP 40 Fixation surface mounting or top-hat rail mounting Colour white - RAL 9016 PC+ABS - FR Dimensions (WxHxD) 110 x 182 x 4 mm 7264H1 ia 4I2Y Serial PC interface PC interface for connecting a PC for call and presence logging. Data transmission can be carried out via serial interfaces RS 422 or RS 22C. Only in connection with the clino opt 99 service computer logging including the clino opt 99 logging software (Part No.: 87991). 7264Z1 Connection board for serial interface 42

44 Central Components 72647A ia 8BG Serial PC interface - communication plus 1 The PC interface is suitable for connecting a PC for logging calls and presences within the nurse call system. In addition, alarm signals, for instance, transmitted by hazard alarm systems can be transferred into the system. 2 Only in connection with PW system clino opt 99 service computer including the PW system clino opt 99 software package (Part No.: 8W210). 7264Z1 Connection board for serial interface I1 ia 4J2^ Serial interface - printer Printer interface for connecting a log printer to the nurse call system. Data transmission can be carried out via serial interfaces RS 422 or RS 22C. Only in conjunction with clino opt 99 zone controller (72640xx) and clock module (72644A1) 7264Z1 Connection board for serial interface 72644A1 ia B2: Serial interface - DCF77 clock module The clock module transmits the DCF77 signals to the nurse call system. The software pakkage for DCF signal evaluation and DCF receiver with 2m connection cable, 9-pin D-Sub plug and corresponding connection board are included. Dimensions (WxHxD) Colour DCF receiver: 6 x 78 x 22 mm DCF receiver: black Only in conjunction with clino opt 99 zone controller (72640xx). DCF receiver, clock module, connection board 7264Z1 Connection board for serial interface Serial interface for connecting a message transfer system Serial interface for connecting a wireless message transfer system are such as paging system or DECT system. All relevant data within the nurse call system are transmitted via a serial interface. Alternatively to7264xx a maximum of 1 item for each system. 7264S1 ia 4T2) clino call HL serial interface Only in connection with clino opt 99 zone controller (72640xx). 7264Z1 Connection board for serial interface 4

45 Central Components 7264R1 ia 4S2$ Serial interface - clino call DECT Only in connection with the clino opt 99 zone controller (72640xx) 7264Z1 Connection board for serial interface 7264B1 ia 4C2; Serial interface - Multitone Only in connection with the clino opt 99 zone controller (72640xx) 7264Z1 Connection board for serial interface 7264D1 ia 4E2E Serial interface - Bosch D6801 Only in connection with the clino opt 99 zone controller (72640xx) 7264Z1 Connection board for serial interface 7264E1 ia 4F2J Serial interface - Bosch ANT6100 Only in connection with the clino opt 99 zone controller (72640xx) 7264Z1 Connection board for serial interface 7264K1 ia 4L2h Serial interface - Tetronik DP6000 Only in connection with the clino opt 99 zone controller (72640xx) 7264Z1 Connection board for serial interface 7264C1 ia 4D2@ Serial interface - for ESPA Only in connection with the clino opt 99 zone controller (72640xx) 7264Z1 Connection board for serial interface 7264Z1 ia 4[2L Connection board for serial interface PC + ABS - FR Only in connection with the clino opt 99 zone controller (72640xx) connection housing, connection terminal 88899A Additional fastening for top-hat rail mounting 44

46 Central Components Configuration / Service Computer / Software B1 ia :C2S Configuration module 2 The configuration module is suitable for easily and quickly entering alphanumeric room identification codes and system parameters. The menu path must be followed for making entries with a barcode reading pen. Equipped with: - 1 barcode reading pen for reading codes - 1 multi-colour encoding board with set barcode table - 1 LCD, 2 x 8-character for menu navigation 4 Dimensions (WxHxD) 2 x 4 x mm 72649BA ia :CBL Configuration module, English version as 72649B1, but English version. 4

47 Central Components on request clino phon 99 operating computer Nurse call system operating computer for the configuration, display, operation and call logging in System clino phon 99. Additionally as an interface to third-party systems such as paging systems, EDP, ZLT etc. Consists of computer with keyboard, mouse, HDD, FDD, DVD-CDR/RW, and interfaces (serial, LAN, USB). minimum configuration: midi-tower casing mainboard with Pentium PIV Celeron 2GHz or equivalent min. 12MB RAM disk drive (FDD) 1* hard drive (HDD) min. 40GB DVD-CDR/RW drive (including software) VGA graphics card (min. 2MB) interfaces 2* RS22, 1* parallel, USB 2* LAN Ethernet (10/100 MBit) ISDN terminal adapter mouse and keyboard DCF-77 radio clock Windows XP Professional operating system remote diagnostics / configuration software system backup software Ackermann clino phon 99 system software Equipped with application software for following functions: - clino phon 99 configuration tool - allocation of room configuration - definition of nurse call system functions and parameters - set-up of call type, call type groups, call type upgrading - configuration of actuators for control of external systems (i.e. light, blinds) - set-up of radio and TV programs - service functions - database management system for data storage - system management tools for system analysis - network functions for system access - freely configurable services (zone networking) - allocation of temporally defined services - selection of call type groups for services - definition of targeted forwarding of messages between nurse call system zones - freely configurable announcement functions (collective announcements) - selection of recipients for collective announcements - fault monitoring and reporting (according to DIN VDE 084) - graphic and tabular call indication ordered according to priority, call type and time of call - presence report AW1 and AW2 - calls (normal call, public washroom call, doctor call, priority call etc.) - fault reports (according to DIN DVE 084 application area II) - call answering (only in connection with a master station) - call cancelling (only in connection with a master station) - selection of rooms (only in connection with a master station) - collective announcement into rooms or selected recipients (only in connection with a master station) - input and management of patient data including management of bed allocation (manual) - access control via user ID (if required) - data output to connected printer Optional: - message transmission to a wireless messaging system (i.e. paging system -PSA- or telecommunication installation -DECT-) - freely configurable recipient addresses for messages from nurse call system zones - definition of display format of messages to be transmitted - set-up of different services (i.e. day / night service) - allocation of repetition times, acoustic call tones, etc. Replacement article for 76M00! The PC fulfills the guidelines for the Configuration of Visual Display Units and Office Workspaces (BGI 60) of the Federal Institute for Occupational Safety and Health. clino phon 99 service computer keyboard mouse DCF 77 radio clock ISDN terminal adapter LED page printer V UPS module Monitors 46

48 Central Components on request clino opt 99 operating computer PW system 1 minimum configuration: midi-tower casing mainboard with Pentium PIV Celeron 2GHz or equivalent min. 12MB RAM disk drive (FDD) 1* hard drive (HDD) min. 40GB DVD-CDR/RW drive (including software) VGA Graphics card (min. 2MB) interfaces 2* RS22, 1* parallel, USB 2* LAN Ethernet (10/100 MBit) mouse and keyboard DCF-77 radio clock RS22 serial connecting cable Windows XP Professional operating system system backup software Ackermann clino opt 99 PW system software Nurse call system operating computer for the display, operation and call logging in System clino opt 99. Additionally as interface to third-party systems such as paging systems, EDP, ZLT etc. Consists of computer with keyboard, mouse, HDD, FDD, DVD-CDR/RW, interfaces (serial, LAN,USB). For connection to the nurse call system via a PC interface (separate). Equipped with application software for the following functions: - clino opt 99 configuration module (floor plan construction) - allocation of room configuration - logging functions - database management system for data storage - network functions for system access - graphic and tabular call indication ordered according to priority, call type and time of call - presence report AW1 and AW2 - calls (normal call, public washroom call, doctor call, priority call etc.) - fault reports (according to DIN DVE 084 application area II) - input and management of patient data including management of bed allocation (manual) - access control via user ID (if required) - data output to connected printer Optional: - Message transmission to a wireless messaging system (i.e. paging system or in-house phone installation -DECT-) - freely configurable recipient addresses for messages from nurse call system zones - definition of the display format of messages to be transmitted - set-up von different services (i.e. day / night service) - allocation of repetition times, acoustic call tones, etc. 2 4 Only in connection with the clino opt 99 (72640xx) zone controller! Replacement article for 76W210! The PC fulfills the guidelines for the Configuration of Visual Display Units and Office Workspaces (BGI 60) of the Federal Institute for Occupational Safety and Health LED page printer V UPS module Monitors 47

49 Central Components on request clino opt 99 operating computer for call logging Nurse call system operating computer for call logging in System clino opt 99. Consists of computer with keyboard, mouse, HDD, FDD, DVD-CDR/RW, interfaces (serial, LAN, USB). For connection to the nurse call system via a PC interface (separate). Equipped with application software for following functions: - call logging - evaluation and analysis functions for saved logs - network functions for system access - data output to connected printer minimum configuration: midi-tower system mainboard with Pentium PIV Celeron 2GHz or equivalent min. 12MB RAM disk drive (FDD) 1* hard drive (HDD) min. 40GB DVD-CDR/RW drive (including software) VGA graphics card (min. 2MB) interfaces 2* RS22, 1* parallel, USB 2* LAN Ethernet (10/100 MBit) mouse and keyboard DCF-77 radio clock serial connecting cable RS22 Windows XP Professional operating system system backup software Ackermann clino opt 99 system software Only in connection with the clino opt 99 (72640xx) zone controller! Replacement article for ! The PC fulfills the guidelines for the Configuration of Visual Display Units and Office Workspaces (BGI 60) of the Federal Institute for Occupational Safety and Health LED page printer V UPS module Monitors on request 17 CRT Monitor 17 monitor for connection to an operating computer or server. Rated voltage Power consumption Operating temperature Weight Dimensions (WxHxD) V AC 0-60 Hz 7 W during operation, 1 W during standby 1 to 2 (20-80% relative humidity) 1 kg 410 x 402 x 420 mm 40cm visible screen diagonal 8 Hz refresh rate at resolution of 1024*768 pixels power management according to EPA Plug and Play according to VESA swivel-tilt base on request 19 TFT Monitor 19 TFT monitor for connection to an operating computer or server. Rated voltage Power consumption Operating temperature Weight Dimensions (WxHxD) V AC 0-60 Hz max. 0 W during operation, 1 W during standby 1 to 2 (20-80% relative humidity kg 426 x 46 x 66 mm 46 cm visible screen diagonal graphics display up to 1024*768 pixels power management according to EPA Plug and Play according to VESA swivel-tilt base 48

50 Central Components on request 17 TFT Monitor 1 4 cm visible screen diagona graphics display up to 1280 * 1024 pixels power management according to EPA Plug and Play according to VESA swivel-tilt base 17 TFT monitor for connection to an operating computer or server. Rated voltage V AC 0-60 Hz Power consumption 40 W during operation, 1 W during standby Operating temperature 1 to 2 (20-80% relative humidity) Weight 4 kg Dimensions (WxHxD) 80 x x 66 mm 2 4 8W210 «94X 6?v clino opt 99 PW system software package clino opt 99 PW software package for block graphics display of calls/ call logging / call evaluation of calls transmitted from the clino opt 99 nurse call system on a customer s PC. It is suitable for managing a paging coupling module, a configuration module (block graphic) and a control panel. For connection to the nurse call system, a PC interface (separate) and 1 null-modem cable (separate) are required. System data is stored in a single user database (separate) C7 SQL database system (single user licence) RS22 serial connection cable 72647A Serial PC interface - communication plus 7264Z1 Connection board for serial interface 74981C7 k 2D8; SQL database system (single user licence) Database system (single user licence) for storing configuration data (layout, paging coupling module) in combination with PW system software «8 ]zmt Serial RS22 connection cable Null modem cable for connecting customer-provided PCs to the clino opt 99 nurse call system for call and presence logging. Cable m (with Sub D socket, 9-pin) 49

51 Central Components «8 ]y4: clino opt 99 (HW/SW) logging package Interface package for clino opt 99 call and presence logging in customer-provided PC, including 87991, 7264H1, 7264Z1, clino opt 99 PC interface with connection board clino opt 99 call and presence log software runs on Windows 9X, 2K, XP Null modem cable for PC connection to the Ackermann clino opt 99 patient call system «9 F 0u Software package clino opt 99 logging Call and presence logging software for connecting the customer-provided PC to the clino opt 99 nurse call system for storing incoming call and presence reports. Data can be easily accessed and edited when using the menu RS22 serial connection cable 7264H1 Serial PC interface 7264Z1 Connection board for serial PC interface clino opt 99 logging package 0

52 Duty Room Components Room Controller 1 728A1 i[ 4B2* Duty room interface (4 lamps), white clino phon 99 2 The duty room interface connects the master station to the corridor databus and simultaneously serves as a corridor lamp. Inputs: Presence I Presence II (optional) Call Doctor call Short-circuit resilient outputs with filament breakage and short-circuit recognition ( for switching on a parallel corridor lamp): Presence lamp I Presence lamp II Call lamp Doctor call lamp Signal line for acoustic call forwarding Bus interfaces: - corridor databus for digital data and audio transmission - interface for connection to the master station - configuration socket for selectable decentralised configuration in conjunction with the configuration module - service socket for connecting analysis tools Installation: The duty room interface is plugged onto the corresponding connection board and is fixed into place by means of a quick-release catch. It is surface mounted with a backbox. Class of protection IP 40 Colour white RAL 9016 lamp cover: white, translucent housing: PC + ABS - FR lamp cover: PC Weight 22 g Dimensions (WxHxD) 18 x 110 x 90, mm 728Z1 clino phon 99 connection board for duty room interface, white 4 728A2 i[ 4B0 Duty room interface (4 lamps), grey clino phon 99 as 728A1, but grey Colour grey RAL Z2 clino phon 99 connection board for duty room interface, grey 728B1 i[ 4C2/ Duty room interface (without lamps) clino phon 99 as 728A1, but without indicator lamp. Colour white RAL 9016 Dimensions (WxHxD) 18 x 110 x 44. mm 728Z1 clino phon 99 connection board for duty room interface, white 1

53 Duty Room Components 728Z1 i[ Connection board, white clino phon 99 Connection board for duty room interface. Dimensions (WxHxD) 18 x 110 x mm Colour white RAL 9016 PC + ABS - FR 728Z2 i[ 4[F Connection board, grey clino phon 99 as 728Z1, but grey Colour grey RAL C2 iz 4D8 Electronic module for duty rooms ( lamps) clino opt 99 Electronic module for duty rooms incl. bed databus with integrated semicircular corridor lamp (three lamp cells including bulb) and service socket. Bed databus for connecting additional bedside call units and display modules in rooms as well as a master station (74420B2) Room calls: normal calls, emergency calls, diagnostic calls, doctor calls WC calls: normal calls, enhanced calls, WC emergency calls Cancellation and presence: combined cancellation/presence, Presence I (green), separate cancellation for bathroom / WC Acoustic signals: call transfer for normal call and emergency call, doctor call, staff call, meal call Optical signals: WC call lamp (white), room call (red), presence indication (green) Security function: short-circuit resilient outputs, 10 min data maintenance during mains failure, data loss monitoring with automatic cold start The duty selection module is connected to select zone interconnection and to set the buzzer volume in case of call forwarding The duty room unit is connected to acknowledge incoming calls Class of protection IP 20 Installation surface mounting Colour red, green, white lamp cover: white, translucent PC+ABS - FR Dimensions (WxHxD) 18 x 87 x 110 mm Available until the end of Q2/ Z2 7271Z E A EM connection board with bed databus, white EM connection board with bed databus, grey Protective hood Name plate holder 2

54 Duty Room Components 727A2 iz 4B. Electronic module (without lamps) clino opt 99 w/o indicator lamp 1 as 727C2, but without indicator lamp. 2 Protection of signal line IP 20 Installation surface mounting Colour cover plate white RAL 9016 PC + ABS - FR Dimensions (HxWxD) 87 x 18 x 110 mm 4 Available until the end of Q2/ Z2 EM connection board with bed databus, white 727D2 iz 4E= Electronic module for duty rooms (4 lamps) clino opt 99 as 727C2, but with second presence (yellow) and 4 lamp cells. Colour red, green, yellow, white Available until the end of Q2/ N1 iz 4O2i Electronic module for duty rooms ( lamps) clino opt 99 as 727D2, but with following additional characteristics: - indicator lamp with power-saving LED technology for long life span - disconnectible indicator lamp (dummy plate for dummy module required) Successor article for 727C, 727C2, 727D, 727D2, 727A, 727A2 Expected date of availability as of Q/ AV Dummy plate (package unit pcs) 7271Z2 iz 2[< Connection board EM 99 with bed databus - white Connection board for electronic module with bed databus including memory module. Colour white RAL Z1 iz 2[26 Connection board for EM 99 with bed databus - grey as 7271Z2, but grey Colour grey RAL 7040

55 Duty Room Components Duty Room Units 74422A1 kk B2o Master station clino phon 99 The master station serves as a display and answering unit in the ward or duty room for interconnecting zones or wards as well as an operating unit for message broadcasting. The graphics display with touch-sensitive surface offers a clear view of all actions as well as easy operation through its clearly arranged menu structure. The associated bus connection unit provides for the connection to the nurse call system. Function activation (i.e. conversation setup / termination, room and bedside communication etc.) via touch screen Call and status identification with 16-character alphanumeric display for each message Simultaneous display of several calls and presences Control of call handling through prioritisation Call acknowledgement for answered calls, either as call on hold or cancelled call Room and bedside call answering / communication Staff communication Discreet or hands-free speech with nursing staff / patient Speech broadcasting in definable areas Configurable and freely selectable zone linking Call release and presence indication Ambient temperature + C to + C Class of protection IP 20 Colour upper housing: white - RAL 9016 lower housing: grey - RAL 70 Housing PC + ABS - FR Weight 12 g Connection length 20 mm Dimensions (LxWxH) 60 x 21 x 80 mm 7070A Databus connection unit for master station Equipped with: 1 handset with loudspeaker and microphone 1 loudspeaker 1 microphone 1 call push-button red with LED orientation/reassurance lamp 1 doctor call push-button with LED reassurance lamp 2 presence push-buttons green/yellow with LED reminder lamps 1 buzzer for call transfer 4 function buttons for volume control, microphone muting and loudspeaker button 2 function buttons for user-specified functions 1 illuminated monochrome STN display (.7 ) with touch-screen 1 headset socket 4

56 Duty Room Components 74420B2 kk 1Cr Master station clino opt 99 1 The master station serves as an indicating and operating unit within the duty room. The graphics display with touch-sensitive surface allows clear and structured display of all events as well as easy menu-guided operation for functions such as interconnecting zones or wards or selecting the defined duty settings such as day / night duty. All components for connection to the electronic module for the duty room are included. Without speech transmission and with integrated doctor call function. 2 Functional range: Call and status identification with indication for zones, rooms, beds, normal calls, bathroom / WC calls, emergency calls, bathroom / WC emergency calls, plug release calls, diagnostic calls, doctor calls, call on hold, Presence I and II, failure, further calls Actuation of calls Actuation of doctor calls Call in remind mode Free selectable zone interconnection Call answering Multiple calls and presence signals are indicated in parallel Functions are activated via touch screen Menu navigation and free assignment of buttons (alphanumeric display) Equipped with: 1 call push-button red with LED orientation / reassurance lamp 1 doctor call lamp - blue - with LED reassurance lamp 2 presence buttons green and yellow with LED reminder lamp 1 sound generator for call transfer 1 illuminated LCD with touch-sensitive surface (touch screen) Assembly desk-top housing with 2 m connection cable and 8-pin plug Class of protection IP 40 upper part: ABS, lower part: anodised aluminium Colour white - RAL 9016 Dimensions (LxWxH) 200 x 228 x 6 mm Only in connection with zone controller clino opt 99 (72640x2). 7070A Databus connection unit for master station 4

57 Duty Room Components 7070A j( 1B! Databus connection unit for master station Databus connection unit with one 8-pin plug contact for connection of master station. Installation in flush-mount box, DIN 4907 Colour white - RAL 9016 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm Class of protection IP 40 when installed incl. according cover plate 88911J Cover plate for databus connection unit 88911J y 2K4F Cover plate for databus connection unit Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 74910C k 1D4x Display module for bed databus The display module with integrated call and cancel push-button can be used for electronic modules with bed databus. When presence is set, pending calls are indicated acoustically and shown in plain text via the display. The display can also be connected to the room terminal as a parallel display. 2 x 8 character illuminated alphanumeric LCD push-buttons for cancel function and presence function LED reminder lamp - green - sound generator for call forwarding LED orientation lamp and reassurance lamp - red - connection terminal Installation in flush-mounted box, DIN 4907 Colour white RAL 9016 Class of protection IP 40 Dimensions (WxHxD) 71 x 71 x 40 mm Replacement article for 74910C2 Display module, flush-mounting installation kit, connection terminals 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 6

58 Duty Room Components 74911B k 2C4w Duty selection module clino opt 99 1 Duty selection module for connection to the electronic module for duty rooms. The type of interconnection is selected and activated via integrated function buttons. 2 2 x 8-character illuminated alphanumeric LCD 2 white push-buttons Connection terminals Installation in flush-mounted box, DIN 4907 Colour white RAL 9016 Class of protection IP 40 PC + ABS - FR duty selection module, connection terminals, flush mounting kit Only in connection with clino opt 99 zone controller (72640x2) A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) B2 ja C> Call / cancel push-button or duty room unit Call / cancel push-button (duty room unit) with flush mount supporting ring and expanding/ retaining clamps for flush mount backboxes. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (BxH) 71 x 71 mm 1 button for cancel and presence function 1 cancel and presence push-button 1 LED reminder lamp - green - 1 LED orientation / reassurance lamp -red- 1 sound generator for call forwarding 88882P Cover plate white for duty room unit 88882P yy Q4b Cover plate white for duty room unit Colour white - RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 1 cancel push-button -green- 1 acknowledge push-button -white- 7

59 Room Components Room Controller 76921B1 m} 2C2o Room terminal clino phon 99 with display and doctor call Short-circuit resilient inputs / outputs: call circuits for doctor call, bathroom call, call 1 call circuit for diagnostic call it can also be configured as an additional output 2 presence call circuits 1 cancel button - bathroom 1 signal line for acoustic call forwarding (buzzer) Lamp outputs with filament breakage and short circuit recognition: call lamp, call lamp - bathroom, Presence I, Presence II The room terminal serves as a central control for all functions in rooms with speech function. Here the room terminal represents the interface between the superordinate corridor databus and the corresponding bed databus. All service elements are color coded or provided with symbols for easy operation. System messages are displayed in plain text via the illuminated LCD display with 2 lines x 8 characters. It is possible to both conduct two-way speech or receive announcements via the built-in speaker and microphone. The room terminal consists of terminal housing with integrated electronics and is easily attached on the corresponding connection board. All configuration data are set-up centrally on the operating computer and stored locally. Parts of this data are also reconfigurable with the configuration module. Bus interfaces: - corridor databus for digital data and audio transmission - bed databus for controlling up to 8 bedside bed combinations or call modules - analog audio line for bedside communication - configuration socket for selectable decentralised configuration in conjunction with the configuration module - service socket for connecting analysis tools Operating voltage 24 V DC Installation sm, fm and cavity wall mounting Protection of signal line IP 40 Colour white RAL 9016 PC + ABS - FR Dimensions (LxWxH) (sm) 280 x 17 x 7, mm 88860FV 76919A B C1 Dummy button set to replace doctor call button sm connection board for clino phon 99 room terminal fm connection board for clino phon 99 room terminal Cavity wall connection board for clino phon 99 room terminal 76920B1 m} 1C2k Room Terminal without display, with doctor call clino phon 99 as 76921B1, but without display and multi-function push-button 88860FV yw 1GW( Doctor call button replacement set (dummy) Dummy push-button to replace the existing clino phon 99 doctor call push-button. Colour white RAL pcs 8

60 Room Components 76919A1 m :B2! Sm connection board for clino phon 99 room terminal 1 Sm connection board suitable for using the room terminal as a distribution point, with plugin terminals for power supply connection, bus lines as well as passive call cancellation units and corridor lamp. The connection board contains over-voltage protection elements for outgoing room cabling. The supply terminals are pluggable screw terminals, all remaining connections use plug-in terminals. 2 Colour white RAL 9016 PC + ABS - FR Dimensions (LxWxH) 20 x 14 x 7. mm 4 Plug-in screw terminals for a maximum of 2 x 2.mm 2 Cu strand with end sleeve, individual power supply for each component within the room (i.e. bedside combination, call module, etc) via plug-in miniature terminals, maximum line cross section of 0.mm B1 m :C2& Fm connection board for clino phon 99 room terminal as 76919A1, but as fm connection board for room terminals. Installation Dimensions (LxWxH) depth: 0 mm 280 x 17 x 1 mm 76919C1 m :D2+ Cavity wall connection board for room terminals as 76919A1, but as cavity wall connection for room terminal. Installation Dimensions (LxWxH) depth: 0 mm 280 x 17 x 1 mm 9

61 Room Components 728C i[ 6D= Room electronic module CLm The 99 CLm electronic module room is the central control unit for rooms without speech function. This unit is also used as a corridor lamp in connection with the corresponding cover plate. The CLm electronic module is equipped with inputs for passive call and cancel units and can control an additional external lamp. The installation is carried out in connection with an installation box. All configuration data are set-up centrally on the operating computer and stored locally. Call circuits: WC call room call selective call bed 1* selective call bed 2* * only in connection with 72660x Call cancel circuits: presence -green- separate WC cancel push-button (optional) bed identification for two beds with call circuit monitoring WC call with separate cancel push-button -piece corridor lamps (disconnectible) terminals for separate indicator lamp connector for CL40/41 corridor lamp (Part No. 726Dx) Operating voltage range Rated voltage Current consumption Rated current Ambient temperature Installation depth Weight Class of protection Dimensions (LxWxH) 88910A 8888CA 88914A 88914B 20.4 to 27.8 V DC 24 V DC 41 to 8 ma 100 ma + C to + C mm 9g IP 40 (IP 44 with sealing kit) 70 x 70 x 7. mm Cover plate Cover plate with kamp cell for 99 CLm room electronic module Mounting frame for cover plate (single) Mounting frame for cover plate (double) 8888CA yy 4DBy Cover plate with lamp cell for 99 CLm room electronic module Colour white, RAL 9016 lamp cover: white, translucent PC+ABS-FR 60

62 Room Components 7270C2 iz 1D, Room electronic module 99 ( lamps), w/o bed databus 1 The electronic module serves as a central unit for controlling all functions within a room. It is available with and without bed databus. Versions without bed databus require passive call push-buttons. At the same time, the electronic module serves as a corridor lamp. All electronic modules are provided with call circuits and call cancel circuits for passive modules with call circuit monitoring. 2 Room calls: normal call, emergency call, diagnostic call, doctor call WC calls: normal call, enhanced call, WC emergency call Cancellation and presence: combined cancellation/presence, Presence 1 (green) separate cancellation for bathroom / WC Acoustic signals: call transfer for normal call and emergency call, doctor call, staff call, meal call Optical signals: WC call lamp (white), corridor lamp (red), presence lamp (green) Security function: short-circuit resilient outputs, call circuit monitoring, 10 min data maintenance during mains failure, data loss monitoring with automatic cold start Class of protection IP 20 Installation surface mounting Colour see connection board lamp cover: white, translucent PC Dimensions (WxHxD) 18 x 87 x 110 mm Availbale until the end of Q2/ Z2 7270Z E A Connection board for electronic module w/o bed databus - white Connection board for electronic module w/o bed databus - grey Protective hood for 721x, 7269x, 727xx, 728x Name plate holder for electronic modules 727xx N1 iz 1O2] Room electronic module 99 CLs ( lamps), w/o bed databus as 7270C2, but with following additional characteristics: - indicator lamp with power-saving LED technology for long life span - bed identification for two beds with call circuit monitoring* *only in connection with 72660x Successor article for 7270C and 7270C2 Expected date of availability as of Q/ Z2 7270Z E A Connection board for electronic module w/o bed databus - white Connection board for electronic module w/o bed databus - grey Protective hood for 721x, 7269x, 727xx, 728x Name plate holder for electronic modules 727xx 7270D2 iz 1E1 Room electronic module 99 (4 lamps), w/o bed databus as 7270C2, but with 4 lamp cells for second presence circuit (yellow). Available until the end of Q2/ Z2 7270Z E A Connection board for electronic module w/o bed databus - white Connection board for electronic module w/o bed databus - grey Protective hood for 721x, 7269x, 727xx, 728x Name plate holder for electronic modules 727xx 61

63 Room Components 7270P1 iz 1Q2g Room electronic module 99 CLs (4 lamps), w/o bed databus as 7270D2, but with following additional characteristics: - indicator lamp with power-saving LED technology for long life span - bed identification for two beds with call circuit monitoring* - disconnectible indicator lamp (dummy plate for dummy module required) *only in connection with 72660x Successor article for 7270D, 7270D2, 7270A, 7270A2 Expected date of availability as of Q/ AV Dummy plate (package unit pcs) 7270A2 iz 1B" Room electronic module 99 (dummy) (w/o lamps), w/o bed databus Electronic module as a dummy module without bed databus and with integrated service socket for application in call systems. Available until the end of Q2/ Z A Connection board for electronic module w/o bed databus - white Name plate holder (nursing home) 7270Z2 iz 1[8 Connection board for EM 99 w/o bed databus - white Connection board for electronic room module without bed databus. Colour white RAL 9016 PC + ABS - FR Dimensions (WxHxD) 18 x 110 x mm connection board, terminals 7270Z1 iz 1[22 Connection board for EM99 w/o bed databus - grey as 7270Z2, but grey Colour grey RAL

64 Room Components 7271C2 iz 2D0 Room electronic module 99 ( lamps) with bed databus 1 Bed databus for connecting additional selective bedside call units and display modules as room modules Connection of speech module enabled (optional) Room calls: normal call, emergency call, diagnostic call, doctor call WC calls: normal call, enhanced call, WC emergency call Cancellation and presence: combined cancellation/presence, presence 1 (green), separate cancellation for bathroom / WC Acoustic signals: call transfer for normal call and emergency call, doctor call, staff call, meal call Optical signals: WC call lamp (white), corridor lamp (red), presence lamp (green) Security function: short-circuit resilient outputs, call circuit monitoring, 10 min data maintenance during mains failure, data loss monitoring with automatic cold start The electronic module serves as a central unit for controlling all functions within a room. It is available with and without bed databus. Subordinate bed databus versions allow the additional connection of active modules such as display modules and up to 8 call modules (installation within the bed databus). Active modules can be assigned an 8-character alphanumeric text for bed identification. At the same time, the electronic module serves as a corridor lamp. Room and bed identification codes are set via the configuration module while commissioning. All electronic modules are provided with call circuits and call cancel circuits for passive modules with call circuit monitoring. Class of protection IP 20 Installation surface mounting Colour see connection board semicircular lamp cover, translucent white PC + ABS - FR Dimensions (WxHxD) 18 x 110 x 87 mm Available until the end of Q2/ Z2 7271Z E A Connection board for electronic module with bed databus - white Connection board for electronic module with bed databus - grey Protective hood for 721x, 7269x, 727xx, 728x Name plate holder for electronic modules 727xx N1 iz 2O2a Room electronic module 99 CLs ( lamps) with bed databus as 7271C2, but with the following additional characteristics: - indicator lamp with power-saving LED technology for long life span - bed identification for two beds with call circuit monitoring* *only in connection with 72660x Successor article for 7271C, 7271C2 Expected date of availability as of Q/ Z2 7271Z E A Connection board for electronic module with bed databus - white Connection board for electronic module with bed databus - grey Protective hood for 721x, 7269x, 727xx, 728x Name plate holder for electronic modules 727xx 7271D2 iz 2E Room electronic module 99 (4 lamps) with bed databus as 7271C2, but with 4 lamp cells for second presence circuit yellow Available until the end of Q2/ Z2 7271Z E A Connection board for electronic module with bed databus - white Connection board for electronic module with bed databus - grey Protective hood for 721x, 7269x, 727xx, 728x Name plate holder for electronic modules 727xx 6

65 Room Components 7271P1 iz 2Q2k Room electronic module 99 CLs (4 lamps) with bed databus as 7271D2, but with following additional characteristics: - indicator lamp with power-saving LED technology for long life span - bed identification for two beds with call circuit monitoring* - disconnectible indicator lamp (dummy plate for dummy module required) *only in connection with 72660x Successor article for 7271D, 7271D2, 7271A, 7271A2 Expected date of availability as of Q/ AV Dummy plate (package unit pcs) 7271A2 iz 2B& Room electronic module 99 (w/o corridor lamp) with bed databus (dummy) Electronic module with bed databus as a dummy module, with integrated service socket, for application in nurse call systems. Available until the end of Q2/ Z2 Connection board for electronic module with bed databus - white 88886A Name plate holder for 7270-x 7271Z2 iz 2[< Connection board EM 99 with bed databus - white Connection board for electronic module with bed databus including memory module. Colour white RAL Z1 iz 2[26 Connection board for EM 99 with bed databus - grey as 7271Z2, but grey Colour grey RAL

66 Room Components 7272D2 iz E9 Room electronic module (4 lamps) with bed databus, radio clino opt 99 1 Bed databus for connecting additional selective bedside call units and display modules within the room Radio programmes can be transmitted to wall electronics Room calls: normal call, emergency call, diagnostic call, doctor call WC calls: normal call, enhanced call, WC emergency call Cancellation and presence: combined cancellation/presence, Presence 1 (green) separate cancellation for bathroom / WC Acoustic signals: call transfer for normal calls and emergency calls, doctor calls, staff call, meal call Optical signals: WC call lamp (white), corridor lamp (red), presence lamp (green) Security function: short-circuit resilient outputs, call circuit monitoring, 10 min data maintenance during mains failure, data loss monitoring with automatic cold start The electronic module serves as a central unit for controlling all functions within a room. It is available with and without bed databus. Subordinate bed databus versions allow the additional connection of active modules such as display modules and up to 8 call modules (installation above the bed databus). Active modules can be assigned an 8-character alphanumeric text for bed identification. At the same time, the electronic module serves as a corridor lamp. Room and bed identification codes are set via the configuration module while commissioning. All electronic modules are provided with call circuits and call cancel circuits for passive modules with call circuit monitoring. Class of protection IP 20 Installation surface mounting Colour see conntection board white lamp cover, transluzent PC Dimensions (WxHxD) 18 x 87 x 110 mm 7272Z2 Connection board for electronic module with bed databus - white 7272Z1 Connection board for electronic module with bed databus - grey 89870E1 Protective hood for 7270-x and 728x 88886A Name plate holder for 7270-x 8889AV Dummy plate (package unit pcs) Z2 iz [@ Connection board for EM 99 with bed databus, radio - white Connection board for electronic module with bed databus, radio and audio equipment including memory module. Colour white RAL 9016 PC + ABS - FR connection board, connection terminals, memory module 7272Z1 iz [2: Connection board for EM 99 with bed databus, radio - grey as 7272Z2, but grey Colour grey RAL A yy 7B Name plate holder for electronic modules 7270-x Name plate holder for electronic room module suitable for receiving a name plate. Colour grau - RAL 7040 PC + ABS - FR 6

67 Room Components Room Terminals 74910C k 1D4x Display module for bed databus The display module with integrated call and cancel push-button can be used for electronic modules with bed databus. When presence is set, pending calls are indicated acoustically and shown in plain text via the display. The display can also be connected to the room terminal as a parallel display. 2 x 8 character illuminated alphanumeric LCD push-buttons for cancel function and presence function LED reminder lamp - green - sound generator for call forwarding LED orientation lamp and reassurance lamp - red - connection terminal Installation in flush-mounted box, DIN 4907 Colour white RAL 9016 Class of protection IP 40 Dimensions (WxHxD) 71 x 71 x 40 mm Replacement article for 74910C2 Display module, flush-mounting installation kit, connection terminals 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 74188A1 k 9B2W Bed module clino phon 99 With the bed module, all required call and cancel functions are available directly at bedside: patient handset, pear push-button or multiple push-button (connection via auto-release plug). Thus, each bed is provided with a speech facility integrated in the patient handset to allow communication (discreet / hands-free) with the nursing staff. A maximum of 8 bed modules can be connected to the room terminal via the bed databus. In conjunction with a control output and an actuator unit, several control functions such as light control can be set up. Equipped with: 1 call push-button red with LED reassurance lamp and orientation lamp 1 connector for the auto-release plug for connecting the patient handset, a pear push-button or a multiple push-button 1 auxiliary plug contact for connecting a pear push-button or a multiple push-button - 7-pin - 1 auxiliary plug contact for connection diagnostic devices with it`s own electrical isolation (DIN ) -6-pin- Loudspeaker and microphone for hands-free function Cancel push-button green Inputs / outputs: TV control TV sound Actuator Ambient temperature + C to + C Version for sm, fm and cavity wall installation Class of protection IP 40 Colour white - RAL 9016 PC + ABS - FR Weight approx. 20 g Dimensions (LxWxH) 228 x 80 x 9, mm Bed module, button replacement set Sm/Fm/Cavity wall connection (red/green) and medical trunking unit (grey with pictogramm red/green) 74174A1 Sm connection board for clino phon 99 bed module 74174B1 Flush mounting connection board for clino phon 99 bed module 74174C1 Cavity wall connection board for clino phon 99 bed modul 74174D1 Trunking unit connection board for bed module clino phon 99 Functions: Nurse call actuation Transmission of nurse call conversations, data, radio programmes, sound for TV Control functions such as light control via a separate control output in conjunction with the actuator unit TV control function 66

68 Room Components 74174A1 k2 B2E Sm connection board for clino phon 99 bed module 1 SM bed module connection board for connecting the bed module with plug-in terminals for passive room components, 24V DC power supply as well as cable conduits for reduced FO cables. 2 Colour white RAL 9016 PC + ABS - FR connection board, connection terminals B1 k2 C2J Flush mounting connection board for clino phon 99 bed module as 74174A1, but as fm connection board 74174C1 k2 D2O Cavity wall connection board for clino phon 99 bed module as 74174A1, but cavity wall connection board D1 k2 E2T Trunking unit connection board for bed module clino phon 99 as 74174A1, but suitable for medical trunking unit. 67

69 Room Components 741A1 k. 4B29 Patient handset clino phon 99 Equipped with: Call push-button - red - with LED reassurance / orientation lamp 2 light buttons - yellow - Function control buttons Microphone for discreet communication Earpiece.mm jack bush for connecting headphones Auto-release system plug for connection to the bedside interface electronics The user-friendly control unit is suitable for actuating calls, selecting radio and TV channels and switching the light on/off as well as for discreet communication with the nursing staff. It is equipped with a clearly structured button panel and orientation / reassurance lamp at the call push-button. With the 2*2-digit seven-segment display, the selected radio channel, TV function as well as the time (when available) is indicated. The patient handset is provided with loudspeakers as well as a headphone jack (.mm jack bush). Its splashing-water protected surface (IP4) can be easily cleaned. The hook on the wall or at the bedside table serves as a handset retainer. The handset is connected to the bedside electronics via an auto-release plug. Class of protection IP 4 Installation tubular at the bedside table / wall Housing colour white - RAL 9016 PC + ABS - GF20 Weight 260 g Connection length 2, m Dimensions (LxWxH) 206 x 71 x 27 mm (7) 2x Cable fixing clip for mobile call units (attached to trapeze bar) 7411B C 74096D Hook for patient handset, patient terminal Headphones with jack bush Cable fixing clip for mobile call units (attached to trapeze bar) 74096D k* 7EM Cable fixing clip for mobile call units (attached to trapeze bar) Cable fixing clip for patient handsets and patient terminal (attached to trapeze bar) 10 pcs 89760C zm 1D^ Earphones with right-angle plug 1 adjustable headband 2 foam pads 1.8 m connection cable 1 stereo right-angle plug (. mm) Headphones with right-angle plug for connection to clino phon 99 patient handsets and clino com 21 patient handsets and terminals. Impedance 2 Ohm Loading capacity max. 0.1W Transmission 40 Hz - 1k Hz Weight 4 g 89760BZ Spare foam pads 68

70 Room Components 7411B1 k. 2C26 Bracket to deposit the patient handset / terminal 1 Bracket to deposit the patient handset / terminal on the bedside table or as a parking station on the wall. 2 Colour white RAL A j( B1 clino phon 99 bed combination unit with one socket Bed combination for call initiation with individual bed identification and bedside hands-free function. Mobile call units such as pear and multiple push-button are connected to the plug connectors. Connection of up to 8 bed combinations using wire-saving technology to a room terminal via the bed databus. Identification display of 1 to 8 digits, freely configurable at call initiation. Monitoring of connected call units (call circuit monitoring). Equipped with: 1 call button with LED reassurance / orientation lamp - red - 1 auxiliary socket for connecting a pear pushbutton or a multiple push-button -7-pin - 1 loudspeaker unit 1 microphone unit Class of protection IP 20 Installation fm or cavity wall installation in combination with x fm box, DIN 4907 Colour white - RAL 9016 PC + ABS - FR Installation depth 40 mm Dimensions (LxWxH) 22 x 81 x 14 mm Inputs / outputs via plug-in terminals for: 1 external call with reassurance / orientation lamp 2 external light buttons 7074B j( C6 clino phon 99 bed combination unit with two sockets as 7074A, but with additional plug sockets for connection of a medical unit (i.e. Infusimat) with alarm contact. 69

71 Room Components 71008C h! 9D4F Loudspeaker Loudspeaker with central insert, fm supporting plate and expanding / retaining clamps for fm backboxes. Impedance 0 Ohm Power 0,1 W Class of protection IP 20 Installation in flush-mounted box DIN 4907 Colour white RAL 9016 Installation depth 40 mm Dimensions (BxH) 71 x 71 mm 88910B Standard plate 88910B y 1C4 Standard plate Standard plate with insertion hole in accordance with DIN Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 71048B h% 9C> Interfacing unit for microphone Microphone interfacing unit for bedside hands-free function. The microphone interfacing unit is connected to the analogue audio bus. The bedside microphone for the corresponding cover plate is enabled via a special control contact of the call module. Class of protection IP 40, when installed with respective cover plate Fixation in fm installation box, DIN 4907 Installation depth 2 mm Dimensions (BxH) 71 x 71 mm 7102D Cover plate including microphone 7102D h& E4= Cover plate including microphone Cover plate with microphone as a supplement for the microphone interfacing unit. The cover plate contains the microphone for bedside hands-free function. Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 70

72 Room Components 7072A2 j( B. Wall electronics clino opt 99 1 Wall electronics for surface mounting as an interface between electronic module and patient handset. For call initiation with individual bed identification. It enables the selection of radio and TV programs as well as the transmission of data and audio signals to the patient handset. Mobile call units (pear and multiple push-button, patient handsets) are connected to the auto-release plug system or to the plug socket (not patient handset). Connection of up to 4 wall electronics using wire-saving technology via the bed databus to an electronic module. Display of identification (up to 8 digits, freely configurable) on call initiation. Monitoring of connected call units (call circuit monitoring). Additional plug socket for connection of a medical unit (i.e. Infusiomat) with alarm contact monitored connector for auto-release plug 1 call push-button with LED orientation/reassurance lamp, red 1monitored auxiliary plug contact for connecting a pear or a multiple push-button, 7-pin 1 monitored auxiliary plug contact for connecting diagnostic equipment, 6-pin Colour white - RAL 9016 PC + ABS-FR Dimensions (LxWxH) 182 x 110 x mm In connection with zone controler clino opt 99 (72640x2) 8890A 8990B 8896B Flush mount base for wall electronics (accessories) Cavity wall base for wall electronics (accessories) Frame for flush or cavity wall mounting base 8890A y 1By Flush mount base for wall electronics (accessories) Colour white RAL 9016 zinc-coated sheet steel installation box, cover 8896B Frame for flush mounting and cavity wall installation 8890B y 1C~ Cavity wall base for wall electronics (accessories) Colour white RAL 9016 zinc-coated sheet steel 8896B Frame for flush mounting and cavity wall installation 8896B y 7C/ Frame for flush or cavity wall mounting base Colour white RAL 9016 PC + ABS-FR 71

73 Room Components 7072B2 j( C Wall electronics MSU clino opt 99 Wall electronics for medical service unit as an interface between electronic module and patient handset for call initiation with individual bed identification. Mobile call units (pear and multiple push-button, patient handsets) are connected to the auto-release plug system or to the plug socket (not patient handset). Connection of up to 4 wall electronics for medical service unit via 40-pin flat ribbon cable to the bed databus of an electronic module (adapter flat ribbon cable- screw terminals required). Display of identification (up to 8 digit, freely configurable) on call initiation. Monitoring of connected call units (call circuit monitoring). 1 monitored connector for auto-release plug 1 call push-button with LED reassurance lamp - red 1 monitored auxiliary socket for connecting a pear push-button or a multiple push-button - 7-pin 1 monitored auxiliary socket for connecting a diagnostic device - 6-pin Colour white - RAL 9016 PC + ABS-FR In connection with zone controler clino opt 99 (72640x2) 76089AL Adapter-pcb for wall electronic 7410A1 k. 1B2- Patient handset (radio, TV) clino opt 99 Nurse call Call actuation Radio and TV Selecting 8 radio channels Selecting TV channels LED display of selected channel Volume control buttons The patient handset with function select button for radio/tv serves as a multifunctional control unit for connection to the wall electronics. Equipped with: - 1 earpiece - 1 call push-button with orientation lamp - 1 LED reassurance lamp - red light buttons - 1 function select button (features) - 2 programme select buttons - 2 volume control buttons - 1 jack bush for connecting headphones - 2m connection cable with auto-release plug Colour white RAL 9016 PC + ABS - FR Dimensions (LxWxD) 180 x 7 x 26 mm Miscellaneous Digital bidirectional data transmission to wall electronics 99 via highly-flexible 6-core connection cables Plug-in system, auto-releasing depending on the mechanical load On switch for reading light On switch for room light 7411A B 74096D Bracket for clino opt 99 patient handset Headphones with jack plug Cable fixing clip for mobile call units (attached to trapeze bar) 72

74 Room Components 7410B1 k. 1C22 clino opt 99 patient handset (radio, external function) 1 Patient handset with function selection button radio button / ext. controlling possibility as a multi-functional operating panel for connection to wall electronics. 2 Nurse call Call actuation Equipped with: - 1 earpiece - 1 call push-button with orientation lamp - 1 LED reassurance lamp - red light buttons - 1 function select button (features) - 2 programme select buttons - 2 volume control buttons - 1 jack plug for connecting headphones - 2 m connection cable with auto-release plug 4 Radio and TV Selecting 8 radio channels LED display of selected channel Volume control buttons Miscellaneous Digital bidirectional data transmission to wall electronics 99 via highly-flexible 6-core connection cables Plug-in system, auto-releasing depending on the mechanical load On switch for reading light On switch for room light Colour white RAL 9016 PC + ABS - FR Dimensions (LxWxD) 180 x 7 x 26 mm 7411A B Bracket for clino opt 99 patient handset Headphones with jack plug 7411A1 k. 2B21 Bracket for clino opt 99 patient handset Holder for patient handset to hang the patient handset on the wall or on the night table. Colour white - RAL 9016 PC + ABS - FR 89760B zm 1CY Headphones with jack plug 1 adjustable headband 2 foam -padded earpieces 1.8 m connector cable Headphones for patient handset and radio unit with volume control. Impedance 2 Ohm Capacity max. 0.1W Input voltage 0.0 W Transmission range 40 Hz - 1 Hz Weight 4 g 89760BZ Spare foam pads 7

75 Room Components 707D j( 4E4G Call module with push-button and 2 sockets Call module for call initiation with individual bed identification for connection to an electronic module or room terminal with bed databus. Mobile call units such as pear and multiple push-button are connected to the plug sockets (7-pin). Additional socket (6-pin) for connection of a medical unit (i.e. Infusiomat) with alarm contact. Connection of up to 8 call modules with wire-saving technology to the bed databus is possible. Identification display (up to 8 digits, freely configurable) on call initiation. Monitoring of connected call units (call circuit monitoring). 1 push-button for call function 1 LED orientation lamp/reassurance lamp - red - 1 socket, 7-pin 1 plug socket for diagnostic units, 6-pin control contact for microphone interfacing unit Class of protection IP 20, when installed with respective cover plate Fixation in flush mount box DIN 4907 Installation depth 2mm Dimensions (BxH) 71 x 71mm Replacement article for 7071D, 707D Call module, connection terminal 88881J Cover plate with push-button (red) for units with 2 sockets 88881J yy 2K4@ Cover plate with push-button (red) for units with 2 sockets Cover plate for call module as well as call unit with call push-button and 2 plug sockets. Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 707E j( 4F4L Call module with push-button and 1 socket as 707D, but with only 1 plug socket (7-pin). Class of protection IP 40, when installed with respective cover plate Fixation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (BxH) 71 x 71 mm Replacement article for 7071E, 707E 1 push-button element for call function 1 LED orientation lamp / reassurance lamp - red - 1 socket, 7-pin plug socket for microphone interfacing unit call module, connection terminal 88881L Cover plate with push-button (red) with 1 socket 74

76 Room Components 88881L yy 2M4J Cover plate with push-button (red) with 1 socket 1 Cover plate for call module as well as call unit with call push-button and plug socket. 2 Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 4 707F j( 4G4Q Call module with call push-button as 707D, but without plug socket (7-pin) and plug socket (6-pin). Possibility of connection to external call device (i.e. auto-release plug system). Class of protection IP 20, when installed with respective cover plate Fixation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (BxH) 71 x 71 mm 1 call push-button element for call function 1 LED orientation lamp / reassurance lamp - red - control contact for microphone interfacing unit 1 connection for external call device (i.e. autorelease plug system) Replacement article for 7071F, 707F Call module, connection terminal 88881K Cover plate with push-button - red K yy 2L4E Cover plate with push-button - red - Cover plate for call module with call push-button - red - Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 7

77 Additional Components System 99 Display Units for Installation in Corridors 7466A1 kb 7B2F Information display (single-sided) for wall mounting system 99 Wall-mounted information display with red LED dot matrix for self-luminous, alphanumeric plain text display. Speakers for announcements (only clino phon 99) as well as a tone generator for acoustic call forwarding are integrated. System message display with room and bed identification (up to 8 characters, alphanumeric) as well as symbols for call type (i.e. public washroom, doctor, fault). Priority-controlled display with automatic scrolling function (including arrow display) with several pending messages of one priority. Optimal time display in digital format (i.e. 1:40). Function monitoring via superordinate control unit (i.e. zone controller). functional range: display with alphanumeric room and bed identification call type display time display (configurable, i.e. if no messages are pending) acoustic call forwarding (configurable) announcements via speaker configurable (only in connection with System clino phon 99) Display LED dot matrix (8 characters + call type symbol) Version for wall mounting Class of protection IP 40 Colour white RAL 9010 zinc-coated sheet steel Dimensions (LxWxH) 71 x x 1 mm Sequence of display: the highest priority messages are displayed (in the sequence: alarm call - emergency call call) If several messages of the same priority are pending, they are alternately scrolled 7466B1 kb 7C2K Information display (single-sided) for ceiling mounting system 99 as 7466A1, but ready for ceiling mounting. Version Dimensions (LxWxH) single-sided for ceilling mounting 71 x x 1 mm 8960C1 Ceiling mounting set 7467A1 kb 8B2J Information display (double-sided) for ceiling mounting system 99 as 7466A1, but double-sided and ready for ceiling mounting. Possibility of system message display from different nurse call zones (front/back). Version Dimensions (LxWxH) double-sided for ceiling mounting 71 x 86 x 1 mm (+ 42 mm center bar) 8960C1 Ceiling mounting set 76

78 Additional Components 8960C1 z] 4D2I Ceiling mounting set 1 Ceiling mounting set for mounting the appropriate information display, single- or doublesided, to ceilings. 2 thermoplastic Colour white RAL 9016 Dimensions length variable up to max. 600 mm 2x swivel tube, suspension kit C2 iz D< Direction lamp 99 with 2 lamp cells (arrows right / left) Direction lamp with 2 lamp cells (neutral design, inscription set included) for directional indication of system messages from different functional areas of the superordinate control unit (here: zone controller). Priority-controlled display with different blinking rates for priorities: alarm call - emergency call - call. Function monitoring via superordinate control unit. 1) call: continuous signal 2) emergency call: 1 second on, 1 second off ) alarm call: 1/2 second on, 1/2 second off Class of protection IP 20 Fixation surface mounting Colour depending on connection board semicircular lamp cover, translucent white PC Dimensions (WxHxD) 18 x 110 x 87 mm Available until the end of Q2/ Z2 7274Z1 Connection board for direction lamp - white Connection board for direction lamp - grey 7274M1 iz N2h Direction lamp 99 CLs with 2 lamp cells as 7274C2, but with following additional characteristics: indicator lamp with power-saving LED technology for long life span Successor article for 7274C, 7274C2 Expected date of availability as of Q/ Z1 it 6[2: Labelling set for zone indicator lamp, mm (accessories) Inscription set in sticker form with numbers and letters with a height of mm. Contains the numbers 0-9 as well as the letters EG, OG, DG. Symbol and direction arrows, Telephone, Fire. Contains 2 sets each 77

79 Additional Components 7274Z2 iz [H Connection board for direction lamp - white Connection board for direction lamp including memory module. Colour white RAL 9016 PC + ABS - FR Dimensions (WxHxD) 18 x 110 x mm Connection board, connection terminals, memory module 7274Z1 iz [2B Connection board for direction lamp - grey as 7274Z2, but grey Colour grey RAL

80 1 2 4 General clino Systems Central Components 80-8 Room Components Additional Components

81 General clino Systems Central Components Power Supply Units and UPS Modules 8994M1 z N2^ Single-phase power supply 24 V DC (A) Single-phase power supply (A) for constant DC supply in nurse call systems. Compact design thanks to modern primary-clocked circuit technology (in accordance with EN ), suitable for top-hat rail mounting in the sub-distribution or also outside the sub-distribution for wall mounting with the 8994MA mounting kit (safety cover). The supply unit output is idling, overload and short-circuit proof. Input voltage / V AC reversible 47-6 Hz Output voltage V DC can be set Output current 24 V / A Class of protection IP 20 Protection low voltage SELV (as per EN 6090, VDE0100 PART 410) PELV (as per VDE0160) Operating temperature 0 ºC - 0 ºC for free convection cooling (20-80% relative air humidity) Storage temperature -2 ºC to +8 ºC Weight 72 g Version for top hat rail mounting in sub-distribution Dimensions (WxHxD) 64 x 124 x 102 mm 8994MA 8994C6 Safety cover and mounting kit for power supply unit (A) UPS module 24V DC (A) for A power supply unit 8994R2 z S} Singel-phase power supply 24 V DC (10A) Single-phase power supply (10A) for constant DC supply in nurse call systems. Compact design thanks to modern primary-clocked circuit technology (in accordance with EN ), suitable for top-hat rail mounting in the sub-distribution or also outside the sub-distribution for wall mounting with the 8994MB mounting kit (safety cover). The supply unit output is idling, overload and short-circuit proof. Input voltage V AC / V AC reversible 47-6 Hz Output voltage 24 to 28 V DC can be set Output current 24 V / 10 A, 28 V / 8.6 A Class of protection IP 20 Protection low voltage SELV (as per EN 6090, VDE0100 PART 410) PELV (as per VDE0160) Operating temperature 0 ºC - 60 ºC for free convection cooling (20-80% relative air humidity) Storage temperature -2 ºC to +8 ºC Weight 119 g Version for top hat rail mounting in sub-distribution Dimensions (WxHxD) 120 x 124 x 102 mm 8994MB Safety cover and mounting kit for power supply unit (10A) 8994C7 UPS module 24V DC (10A) for 10A power supply unit 80

82 General clino Systems Central Components 8994R z S4 Singel-phase power supply 24VDC (20A) 1 Single-phase power supply (20A) for constant DC supply in nurse call systems. Compact design thanks to modern primary-clocked circuit technology (in accordance with EN ), suitable for top-hat rail mounting in the sub-distribution or also outside the sub-distribution for wall mounting with the 8994MC mounting kit (safety cover). The supply unit output is idling, overload and short-circuit proof. 2 Input voltage V AC / V AC reversible 47-6 Hz Output voltage 24 to 28V DC can be set Output current 24 V / 20 A, 28 V / 18 A Type of protection IP 20 Protection low voltage SELV (as per EN 6090, VDE0100 PART 410) PELV (as per VDE0160) Operating temperature 0 ºC - 60 ºC for free convection cooling (20-80% relative air humidity) Storage temperature -2 ºC to +8 ºC Weight 1800 g Version for top hat rail mounting in sub-distribution Dimensions (WxHxD) 220 x 124 x 102 mm MC 8994C8 Safety cover and mounting kit for power supply unit (20A) UPS module 24V DC (20A) for 20A power supply unit 8994MA z NBW Safety cover and mounting kit for power supply unit (A) Safety cover and mounting kit (for A power supply) for wall mounting power supplies outside a sub-distribution. Colour grey - RAL 70 - top hat rail is included 8994MB z NC] Safety cover and mounting kit for power supply unit (10A) Safety cover and mounting kit (for 10A power supply) for wall mounting power supplies outside a sub-distribution. Colour grey - RAL 70 - top hat rail is included 8994MC z NDc Safety cover and mounting kit for power supply unit (20A) Safety cover and mounting kit (for 20A power supply) for wall mounting power supplies outside a sub-distribution. Colour grey - RAL 70 - top hat rail is included 81

83 General clino Systems Central Components 8994C6 z D7J UPS module 24V DC (A) for A power supply unit Uninterruptible power supply 24V DC / A (online DC-UPS) as supplement to 24V DC power supply. Designed for establishing a secure, fully uninterruptible 24V DC power supply and assumes the uninterruptible power supply of the connected call system along with the UPS device s 24V DC power supply during power failure by engaging a battery module. Power failures as well as disturbances are reported according to DIN VDE 084 Parts 1 + 2: When supply voltage is present, the power supply unit supplies the devices and simultaneously charges the UPS device s batteries. Nominal input voltage 24 V DC Input voltage V DC Output voltage when battery-drive: typ V DC Charging time for discharged batteries up to 90% approx. 14 hrs Switching threshold for pre-warning of battery switch-off typ. 19. V Switching threshold for total discharge protection typ. 19. V Type of protection IP 20 Cooling free air convection Ambient temperature C Weight UPS module: 2. kg battery:.6 kg Installation UPS module: terminal for top-hat rail assembly Fixation battery mounting: wall mounting (16 x 11 mm) Battery capacity 7 Ah Battery operating time (for 80% 20 C) approx. 60 minutes Charging current typ A switchable in increments Dimensions (WxHxD) UPS module: 70 x 126 x 128. mm Battery: 180 x 19 x 110 mm The battery is wall mounted within the sub-distribution. 8994C7 z D8P UPS module 24V DC (10A) for 10A power supply unit as 8994C6, but 10A. Weight Installation Battery capacity Battery operating time Charging current Dimensions (WxHxD) battery: 12.7 kg battery mounting: wall mounting (86 x 140 mm) 1Ah (for 70% 20 C) approx. 60 minutes typ A switchable in increments UPS module 70 x 141 x 11 mm battery: 40 x 178 x 1 mm 8994C8 z D9V UPS module 24V DC (20A) for 20A power supply unit as 8994C6, but 20A. Weight Installation Battery capacity Battery operating time Charging current Dimensions (WxHxD) battery: 20. kg battery mounting: wall mounting (86 x 140 mm) 24 Ah (for 60% 20 C) approx. 60 minutes typ A switchable in increments UPS module 86 x 220 x 160 mm battery: 40 x 178 x 1 mm 82

84 General clino Systems Central Components 76089AC m) :BDN UPS module 20V AC (19 installation) 1 UPS module 20 V (built-in, 19 ) for uninterruptible power supply of the server and of the data management processor in the clino com 21 System as well as of the operating computer in System Bridging time by 100% load - 10 minutes Input voltage 20 V AC ± 2% Input current. A Output current.0 A Output voltage 20 V AC ± 2%; 0/60 Hz ± 0.1% Ambient temperature 0 C - 40 C Relative humidity 0-9% non-condensing Version for mounting in 19 cabinet Weight 16.4 kg Dimensions 2 U, D = 90 mm «8 ]z$u UPS module 20V AC (freestanding device) UPS module 20 V for uninterruptible power supply of the server and of the data management processor in the clino com 21 System as well as of the operating computer in System 99. Bridging time by 100 % load - 10 minutes Input voltage 20 V AC ± 2% Input current. A Output voltage 20 V AC ± 2%; 0/60 Hz ± 0.1% Output current.0 A Temperature range 0 C - 40 C Relative humidity 0-9% non-condensing Weight 12. kg Dimensions (WxHxD) 140 x 190 x 440 mm 8

85 General clino Systems Room Components Room Terminals 707B j( 6C: Call push-button with 2 monitored sockets Call unit for call initiation to connect to an electronic module or room terminal via a passive input. Mobile call units such as pear and multiple push-buttons are connected to the plug sockets (7-pin). Additional plug socket (6-pin) for connection of a medical unit (i.e. Infusiomat) with alarm contact. Room identification displayed at call initiation. Monitoring of connected call units (call circuit monitoring). 1 call push-button 1 LED orientation / reassurance lamp -red- 1 monitored socket, 7-pin 1 monitored socket, 6-pin Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71mm call push-button, connecting terminals w/o screws 88881J Cover plate with push-button (red) for units with 2 sockets 88881J yy 2K4@ Cover plate with push-button (red) for units with 2 sockets Cover plate for call module as well as call unit with call push-button and 2 plug sockets. Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 707A j( 6B Call push-button with 1 monitored socket as 707B, but with plug socket 7-pin. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box DIN 4907 Dimensions (WxH) 71 x 71mm call push-button, connection terminals w/o screws 1 call push-button 1 LED orientation / reassurance lamp -red- 1 monitored socket, 7-pin 88881L Cover plate with push-button (red) with 1 socket 84

86 General clino Systems Room Components 88881L yy 2M4J Cover plate with push-button (red) with 1 socket 1 Cover plate for call module as well as call unit with call push-button and plug socket. 2 Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 4 707D j( 6ED Call unit with 2 diagnostic sockets as 707B, but with 2 plug sockets 6-pin as well as without call push-button. Connection of 2 medical units (i.e. Infusiomat) with alarm contact possible. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 2 monitored sockets, 6-pin 88912D Cover plate for call unit with 2 dignostic sockets 88912D y E4, Cover plate for call unit with 2 dignostic sockets Cover plate for call unit with 2 dignostic sockets Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 7022A2 j# B$ Call push-button Call push-button for call initiation to connect to an electronic module or room terminal via a passive input. Superordinate room identification displayed at call initiation. Function monitoring is carried out by the electronic module or room terminal (call circuit monitoring). 1 call push-button 1 LED orientation / reassurance lamp red Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 88881G Cover plate with push-button - red D Cover plate with push-button -blue- (doctor call button) 8

87 General clino Systems Room Components 88881G yy 2H41 Cover plate with push-button - red - Cover plate with one call push-button -red- Colour white RAL 9016 PC + ABS - FR 88160A 88914A 88914B 88914C IPx4 sealing kit ( pcs) Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 88881D yy 2E4" Cover plate with push-button -blue- (doctor call button) Cover plate with one doctor call button -blue-. Colour white RAL 9016 PC + ABS - FR 88160A 88914A 88914B 88914C IPx4 sealing kit ( pcs) Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 70006C g! 7D2 Pneumatic call push-button Call push-button for pneumatic actuation in connecting to an electronic module or room terminal via a passive input. Superordinate room identification displayed at call initiation. Function monitoring is carried out by the electronic module or room terminal (call circuit monitoring). 4m insulating plastic tube and rubber ball 1 reassurance lamp - red- Class of protection IP 40, when installed incl. according cover plate Version for normally closed circuit system Fixation in flush mount box, DIN 4907 Installation depth 40 mm Version for normally closed circuit system Weight 19 g Dimensions (BxH) 71 x 71 mm 88880C Cover plate for pneumatic call push-button 88880C yy 1D4 Cover plate for pneumatic call push-button Colour white - RAL 9016 PC + ABS - FR 88160A IPx4 sealing kit ( pcs) 88914A Mounting frame for cover plate (single) 88914B Mounting frame for cover plate (double) 88914C Mounting frame for cover plate (triple) 86

88 General clino Systems Room Components 7004A g% 6B47 Call switch with pull cord and knob 1 Pull cord for connection to an electronic module or room terminal via a passive input. Superordinate room identification displayed at call initiation. Function monitoring is carried out by the electronic module or room terminal (call circuit monitoring). 2 2m PVC cord with red knob 1 LED reassurance lamp - red - Class of protection IP 40, when installed incl. according cover plate moulding material: ABS Installation in flush mount box, DIN 4907 Version for normally closed circuit system Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 88880A Cover plate for call switch with pull cord A yy 1B4v Cover plate for call switch with pull cord Colour white - RAL 9016 PC + ABS - FR 88160A 88914A 88914B 88914C IPx4 sealing kit ( pcs) Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 7642B2 ja C> Call / cancel push-button or duty room unit Call / cancel push-button (duty room unit) with flush mount supporting ring and expanding/ retaining clamps for flush mount backboxes. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (BxH) 71 x 71 mm 1 button for cancel and presence function 1 cancel and presence push-button 1 LED reminder lamp - green - 1 LED orientation / reassurance lamp -red- 1 sound generator for call forwarding 88882A Cover plate for call/cancel push button with push-buttons - red and green A yy B4~ Cover plate for call/cancel push button with push-buttons - red and green - Colour white RAL 9016 PC + ABS - FR 88160A IPx4 sealing kit ( pcs) 88914A Mounting frame for cover plate (single) 88914B Mounting frame for cover plate (double) 88914C Mounting frame for cover plate (triple) 87

89 General clino Systems Room Components 7642C ja D> Cancel push-button - PR 1 - Cancel push-button with flush mount supporting ring and expanding/retaining clamps for flush mount backboxes. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 1 LED reminder lamp - green - 1 cancel and presence push-button 1 sound generator for call forwarding 88881H Cover plate with button - green H yy 2I46 Cover plate with button -green- Colour white RAL 9016 PC + ABS - FR 88160A 88914A 88914B 88914C IPx4 sealing kit ( pcs) Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 7642D ja EC Cancel push-button - PR 2 - Cancel push-button with flush mount supporting ring and expanding/retaining clamps for flush mount backboxes. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 1 LED reminder lamp yellow 1 cancel and presence push-button 1 sound generator for call forwarding 88881M Cover plate with button - yellow M yy 2N4O Cover plate with button - yellow - Colour white RAL 9016 PC + ABS - FR 88160A IPx4 sealing kit ( pcs) 88914A Mounting frame for cover plate (single) 88914B Mounting frame for cover plate (double) 88914C Mounting frame for cover plate (triple) 88

90 General clino Systems Room Components 7642E ja FH Cancel push-button - PR 1 / PR 2-1 Cancel push-button with flush mount supporting ring and expanding/retaining clamps for flush mount backboxes. 2 2 cancel and presence push-buttons 2 LED reminder lamps - green - and - yellow - 1 sound generator for call forwarding Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 88882B Cover plate with buttons - green / yellow B yy C4 Cover plate with buttons - green / yellow - Colour white RAL 9016 Pc + ABS - FR 88160A 88914A 88914B 88914C IPx4 sealing kit ( pcs) Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 88160A y1 1BB Sealing kit for standard installations The sealing kit guarantees IPx4 humidity protection for call and cancel push-buttons as well as for pull cords. The kit can also be used in places that need to be protected against splash water and it can be retrofitted in already existing installations. One package includes sealing kits for a maximum of call and cancel buttons or pull cords. pieces 74189A k :B\ Auto-release plug system - A-coded Auto-release plug system - A-coded - for connecting pear or multiple push-buttons with auto-release plug. It is suitable for fm combination boxes and fm backboxes with 60mm screw fixing groove. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 88910N Cover plate for auto-release jack - A-coded 89

91 General clino Systems Room Components 88910N y 1O4V Cover plate for auto-release jack - A-coded Colour white - RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 74199A k4 :B^ Auto-release plug system Auto-release plug system for connecting pear push-buttons or multiple push-buttons with auto-release plug. It is suitable for fm combination boxes and fm backboxes with 60mm screw fixing groove. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 88880D Cover plate for auto-release plug system 88880D yy 1E4 Cover plate for auto-release plug system Colour white - RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 7118D2 h 6E] Sensor push-button as cancel push-button The sensor push-button works as a cancel push-button with LED orientation / reassurance lamp - green - and with a 4mm polished chrome-platted brass cover, ø 70mm and hexagon socket set screws as front plate fixing. 8940B Backbox for sensor push-button 90

92 General clino Systems Room Components 7118E2 h 6Fb Sensor push-button as call push-button 1 The sensor push-button works as a call push-button with LED orientation / reassurance lamp - red - and with a 4mm polished chrome-platted brass cover, ø 70mm and hexagon socket set screws as front plate fixing B Backbox for sensor push-button B zn 1C Backbox for sensor push-button For flush mounting touch sensitive call push-buttons, with back and side entry. steel, galvanized and chromatized steel 1 metal spacer for plaster tolerance 1 dust cover 1 gasket 1 anchor plate Mobile Room Terminals 74141B1 k/ 2C28 Pear push-button (NCC) 7-pin plug, m Pear push-button with 7-pin plug, connection cable and slot for line insertion to enable variable looping and pull relief. ABS Colour white - RAL 9016 Version for normally closed circuit systems Dimensions (WxLxD) 40 x 110 x 18 mm 1 call push-button - red - with nursing staff symbol, suitable for call circuit monitoring 1 LED orientation / reassurance lamp - red C1 k/ 2D2= Pear push-button (NCC) 7-pin plug, m as 74141B1, but with m connection cable. 91

93 General clino Systems Room Components 74141B k/ 2C4D Pear push-button (NCC) auto-release plug, m Pear push-button with auto-release plug, connection cable and slot for line insertion to enable variable looping and pull relief. ABS Colour white - RAL 9016 Version for normally closed circuit systems Dimensions (WxLxD) 40 x 110 x 18 mm 1 call push-button - red - with nursing staff symbol, suitable for call circuit monitoring 1 LED orientation / reassurance lamp - red C k/ 2D4I Pear push-button (NCC) auto-release plug, m as 74141A, but with m connection cable B4 k/ 2CJ Pear push-button (NCC) auto-release plug-a-, m Pear push-button with with A-coded auto-release plug, connection cable and slot for line insertion to enable variable looping and pull relief. Colour white - RAL 9016 ABS Version for normally closed circuit systems Dimensions (WxLxD) 40 x 110 x 18 mm 1 call push-button - red - with nursing staff symbol, configured for call circuit monitoring 1 LED orientation / reassurance lamp - red - Unsuitable for System cc C4 k/ 2DO Pear push-button (NCC) auto-release plug - A -, m as 74141B4, but with m connection cable. Unsuitable for System cc B7 k/ 2C8\ Pear push button, m, auto-release L (NCC) Pear push-button with L-coded auto-release plug and connection cable for connection to a bed module or call module, with push-button contact monitoring. Connection cable and slot for line insertion for variable loop forming and pull relief. 1 call push-button - red - with nursing staff symbol and LED reassurance / orientation lamp ABS Colour white - RAL 9016 Version for normally closed circuit systems Dimensions (WxLxD) 40 x 110 x 18 mm 92

94 General clino Systems Room Components 74141C7 k/ 2D8a Pear push-button (NCC) auto-release plug -L-, m 1 as 74141B7, but with m connection cable B1 k0 2C2: Multiple push-button (NCC) 7-pin plug, 1 light button, m Multiple push-button with 7-pin plug, connection cable and slot for cable insertion to enable variable looping and pull relief. 4 ABS Colour white - RAL 9016 Version for normally closed circuit systems Dimensions (WxLxD) 40 x 110 x 18 mm 1 call push-button - red - with nursing staff symbol, suitable for call circuit monitoring 1 LED orientation / reassurance lamp - red - 1 light push-button - yellow - 741B1 k0 4C2B Multiple push-button (NCC) 7-pin plug, 2 light button, m Multiple push-button with 7-pin plug, connection cable and slot for cable insertion to enable variable looping and pull relief. ABS Colour white - RAL 9016 Dimensions (WxLxD) 40 x 110 x 18 mm Version for normally closed circuit systems 1 call push-button - red - with nursing staff symbol, suitable for call circuit monitoring 1 LED orientation / reassurance lamp - red - 2 light push-buttons - yellow - (separate circuits) 741C1 k0 4D2G Multiple push-button (NCC) 7-pin plug, 2 light buttons, m as 741B1, but with m connection cable. 9

95 General clino Systems Room Components 741B k0 4C4N Multiple push-button (NCC) auto-release plug, 2 light button, m Multiple push-button with auto-release plug, connection cable and slot for cable insertion to enable variable looping and pull relief. ABS Colour white - RAL 9016 Version for normally closed circuit systems Dimensions (WxLxD) 40 x 110 x 18 mm 1 call push-button - red - with nursing staff symbol, suitable for call circuit monitoring 1 LED orientation / reassurance lamp - red - 2 light push-buttons - yellow - (separate circuits) 741C k0 4D4S Multiple push-button (NCC) auto-release plug, 2 light button, m as 741B, but with m connection cable. 741B4 k0 4CT Multiple push-button (NCC) auto-release plug -A-, 2 light button, m Multiple push-button with A-coded auto-release plug, connection cable and slot for cable insertion to enable variable looping and pull relief. ABS Colour white - RAL 9016 Version for closed circuit systems Dimensions (WxLxD) 40 x 110 x 18 mm 1 call push-button - red - with nursing staff symbol, configured for call circuit monitoring 1 LED orientation / reassurance lamp - red - 2 light push-buttons - yellow - (seperate circuits) Unsuitable for System cc C4 k0 4DY Multiple push-button (NCC) auto-release plug -A-, 2 light button, m as 741B4, but with m connection cable. Unsuitbale for System cc

96 General clino Systems Room Components 741B7 k0 4C8f Multiple push-button (NCC), auto-release L, 2 light button, m 1 Multiple push-button with L-coded auto-release plug and connection cable for connection to a bed module or call module, with call button contact monitoring. Connection cable and slot for line insertion to enable variable loop forming and pull relief. 2 ABS Colour white - RAL 9016 Dimensions (WxLxD) 40 x 110 x 18 mm 4 1 call push-button - red - with nursing staff symbol and LED reassurance / orientation lamp 2 light push-button - yellow - (separate circuit) 741C7 k0 4D8k Multiple push-button (NCC), auto-release plug -L-, 2 light button, m as 741B7, but with m connection cable. Special Call Units 700A j? 1BO Noise level sensor Noise level sensor with adjustable noise threshold / call actuation time, microphone, call push-button (red) and push-button to block calls for noise threshold testing, 2 LED control lights, 2m connection cable with 7-pin diode plug. Colour black - RAL 9011 Dimensions (WxHxD) 1 x 9 x 8 mm 1 microphone 1 call push-button 1 push-button to block calls for noise threshold testing 2 LED control lights 2m connection cable with 7-pin plug 70007A g! 8B, Pneumatic pear push-button (NCC) 7-pin plug, 1.9 m Pneumatic pear push-button with 7-pin connection plug, 1.9m insulating plastic tube with rubber ball and retaining clip. Colour Input voltage Version white 24 V for normally closed circuit systems 1.9m insulating plastic tube with rubber ball and retaining clip 9

97 General clino Systems Room Components 70007B g! 8C1 Pneumatic breath call unit (NCC) 7-pin plug Pneumatic breath call unit with 7-pin connection plug. It is suitable for patients who cannot move. The call actuated pneumatic via strong breath into the unit. The unit is connected to the nurse call system via a 7-pin auxiliary plug contact. Version Input voltage for normally closed circuit systems 24 V - AC/DC 7000BZ Spare tube for 70007B pneumatic call unit 7000BZ g! 6C[P Spare tubes for pneumatic call unit 70007B for pneumatic call units 7000B / 70007B 12 spare tubes with filter 710A1 j@ 1B2P Radio call set with handheld transmitter Radio call set with handheld transmitter for mobile call release in resident`s rooms. After call actuation, the call is transmitted to the radio receiver, which is connected to the nurse call system via a 7-pin plug. 1 single channel handheld transmitter with confirmation control (red LED) 1 radio receiver with 7-pin plug for call unit and 0.m connection cable Power supply Dimensions (WxHxD) handheld transmitter, radio receiver, battery (handheld transmitter) 12 V battery (included) (radio receiver) 12 - V DC or 12-0 V AC (handheld transmitter) 1 x x 17 mm (radio receiver) 6 x 110 x 2 mm 710B1 j@ 1C2U Radio call set with bracelet transmitter Radio call set with bracelet transmitter for mobile call release in resident`s rooms. After call actuation, the call is transmitted to the radio receiver, which is connected to the nurse call system via a 7-pin plug. 1 single channel bracelet transmitter with confirmation control (red LED) 1 radio receiver with 7-pin plug for call unit and 0.m connection cable Power supply Dimensions (WxHxD) bracelet transmitter, radio receiver, battery (bracelet transmitter) V battery (included) (radio receiver) 12 - V DC or 12-0 V AC (bracelet transmitter) 2 x x 17 mm (radio receiver) 6 x 110 x 2 mm 96

98 General clino Systems Room Components 710C1 1D2Z Handheld transmitter for radio call set (accessories) 1 Radio transmitter as 1-channel handheld transmitter with confirmation control (red LED). 2 Power supply Dimensions (WxHxD) 12 V battery 2 x x 17 mm radio handheld transmitter, battery 4 710D1 j@ 1E2_ Bracelet transmitter for radio call set (accessories) Radio transmitter as 1-channel bracelet transmitter with confirmation control (red LED). Power supply Dimensions (Ø) Dimensions (WxHxD) V battery mm 2 x x 17 mm radio bracelet transmitter, battery 710E1 j@ 1F2d Radio receiver Radio receiver with 7-pin plug for call unit and 0. m connection cable. Power supply Dimensions (WxHxD) 12 - V DC or 12-0 V AC 6 x 110 x 2 mm «8 ]zvs Scanner module for disorientated people system Scanner module for the disorientated people system for detecting alarms and transmitting them to the nurse call system. One output is monitored via the scanner module and the alarm detector that is inserted into the patient s sole. In case of alarm, the signal is transmitted to the nurse call system via an electronic module. A receiving antenna is connected to the scanner module. Version Power supply Dimensions (LxWxH) Wandmontage 24 V DC 20 x 11 x 0 mm Alarm detector (breaker) for desorientated people system Alarm detector (breaker) for desorientated people system 97

99 General clino Systems Room Components «8 ]zwx Alarm detector (breaker) for disorientated people system The alarm detector (breaker) for the disorientated people system is inserted into the sole of the person who needs to be protected. Alarms are actuated via the scanner module. The alarm detector is suitable for maximum door widths of m. Dimensions (BxH) 46 x 46 mm «8 ]zx] Alarm detector (breaker) for disorientated people system The alarm detector (breaker) for the disorientated people system is inserted into the sole of the person who needs to be protected. Alarms are actuated via the scanner module. The alarm detector is suitable for maximum door widths of 2m. Dimensions (BxH) 28 x 7 mm 98

100 General clino Systems Additional Components Display Units for Installation in Corridors C iy :DI Corridor lamp CL10 with lamp cells 2 The corridor lamp is connected to the room terminal or it serves as a parallel indicator for the electronic module. Class of protection IP 40 Installation surface mounting Colour semicircular lamp cover, white, translucent Dimensions (WxHxD) 18 x 110 x 87 mm corridor lamp, lamp (bulb) Z2 7269Z4 Connection board for corridor lamps CL1x/14x, grey Connection board for corridor lamps CL1x/14x, white 7269CL iy :DM Corridor lamp CL11 with LED technology with lamp cells as 7269C, but with power-saving LED technology and with long life span. 7269Z2 7269Z4 Connection board for corridor lamps CL1x/14x, grey Connection board for corridor lamps CL1x/14x, white 7269D iy :EN Corridor lamp CL140 with 4 lamp cells The corridor lamp is connected to the room terminal or it serves as a parallel indicator for the electronic module. Class of protection IP 40 Installation surface mounting Colour semicircular lamp cover, white, translucent Dimensions (WxHxD) 18 x 110 x 87 mm corridor lamp, lamp (bulb) 7269Z2 7269Z4 Connection board for corridor lamps CL1x/14x, grey Connection board for corridor lamps CL1x/14x, white 7269DL iy :EM! Corridor lamp CL141 with LED technology with 4 lamp cells as 7269D, but with LED technology 7269Z2 Connection board for corridor lamps CL1x/14x, grey 7269Z4 Connection board for corridor lamps CL1x/14x, white 99

101 General clino Systems Additional Components 7269Z4 iy :[f Connection board for corridor lamps CL1x/14x, white Colour white RAL 9016 PC + ABS-FR Dimensions (HxWxD) 18 x 110 x mm 7269Z2 iy :[Z Connection board for corridor lamps CL1x/14x, grey as 7269Z4, but grey Colour grey, RAL B1 ix 6C21 Small corridor lamp CL220 with LED technology (red/green) Corridor lamp for homelike ambiance, with LED technology with 2 lamp cells, suitable for installation in a circular fm backbox. Type of protection IP 40 Colour cover plate: white - RAL 9016 LEDs: red, green Weight 67 g Fixation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxHxD) 71 x 10 x 71 mm corridor lamp, cover plate, mounting frame 18971A fm backbox 72C1 ix 6D26 Small corridor lamp CL10 with LED technology (white/red/green) as 72B1, but with lamp cells Colour LEDs: red, white, green 72D1 ix 6E2; Small corridor lamp CL21 with LED technology (red/green/yellow) as 72C1, but Colour LEDs: red, yellow, green 100

102 General clino Systems Additional Components 726D1 ix 7E2? LED corridor lamp CL40 silver 1 Stylish LED lamp (optionally with name plate) as a corridor lamp with LED technology for the highest architectural demands. 180 degree mounting also possible with LED lamp. The colour sequence remains the same due to the lamp insert which is also rotatable. Usage of an optional name plate is possible. Optionally with or without lighting element for illumination of the name plate. 2 Colour Installation Dimensions (WxHxD) LED s white, red, green, yellow on sm installation box or directly on the wall 120 x 110 (119) x 0 (42.4) mm 4 726S1 ix 7T2# Name plate for LED corridor lamp CL40 Can be installed individually as well as in connection with the LED corridor lamp. The labelling is easy to create and is exchangeable. The removal of the label is carried out by removing the transparent cover. Dimensions (WxHxD) 120 x 108 x 0 mm 726L1 ix 7M2g Lighting for name plate as optional lighting element for the LED lamp name plate 721A4 it 6B6 Zone indicator lamp with 1 lamp, neutral, white It is tailored to the corridor lamp design. It provides with one lamp cell for each lamp cover. Class of protection IP 20 Installation surface mounting Colour plastic base white RAL 9016 lamp cover white, translucent base plate white - RAL 9001 Dimensions (WxHxD) 18 x 110 x 87 mm zone indicator lamp, plastic base, base plate, lamps 721Z1 Labelling set for zone indicator lamp, mm (accessories) 721Z2 Labelling set for zone indicator lamp, 0 mm (accessories) 101

103 General clino Systems Additional Components 721A1 it 6B2$ Zone indicator lamp with 1 lamp, neutral, grey as 721A4, but Colour plastic base grey RAL B4 it 6C; Zone indicator lamp with 2 lamps, neutral, white as 721A4, but with 2 lamps Dimensions (WxHxD) 18 x 220 x 87 mm 721B1 it 6C2) Zone indicator lamp with 2 lamps, neutral, grey as 721B4, but Colour plastic base grey RAL C4 it 6D@ Zone indicator lamp with lamps, neutral, white as 721A4, but with lamps Dimensions (WxHxD) 18 x 0 x 87 mm 721C1 it 6D2. Zone indicator lamp with lamps, neutral, grey as 721C4, but Colour plastic base grey RAL

104 General clino Systems Additional Components 721D4 it 6EE Zone indicator lamp with 4 lamps, neutral, white 1 as 721A4, but with 4 lamps Dimensions (WxHxD) 18 x 440 x 87 mm D1 it 6E2 Zone indicator lamp with 4 lamps, neutral, grey as 721D4, but Colour plastic base grey, RAL E4 it 6FJ Zone indicator lamp with lamps, neutral, white as 721A4, but with lamps Dimensions (WxHxD) 18 x 0 x 87 mm 721E1 it 6F28 Zone indicator lamp with lamps, neutral, grey as 721E4, but Colour plastic base grey, RAL Z1 it 6[2: Labelling set for zone indicator lamp, mm (accessories) Inscription set in sticker form with numbers and letters with a height of mm. Contains the numbers 0-9 as well as the letters EG, OG, DG. Symbol and direction arrows, Telephone, Fire. Contains 2 sets each 721Z2 it 6[@ Labelling set for zone indicator lamp, 0 mm (accessories) as 721Z1, but with a height of 0 mm. 10

105 General clino Systems Additional Components Additional Indicator Lamp Units 88894A yz B} Bulb - transparent - Spare bulb for electronic modules room and corridor lamps. Power supply Colour 24 V/. W white 88894B yz C Bulb - red - as 88894A, but red Colour red 88894C yz D Bulb - green - as 88894A, but green Colour green 88894D yz E% Bulb - yellow - as 88894A, but yellow Colour yellow 88894AL yz BMP LED - transparent - ( pcs) LED lamp to equip a normal electronic module with LEDs. Colour transparent pcs 104

106 General clino Systems Additional Components 88894BL yz CMU LED - red - ( pcs) 1 as 88894AL, but red Colour pcs red CL yz DMZ LED - green - ( pcs) as 88894AL, but green Colour green pcs 88894DL yz EM_ LED - yellow - ( pcs) as 88894AL, but yellow Colour yellow pcs 89870E1 zx 1F2} Protective hood for 721x, 7269x, 727xx, 728x 8889AV yz 4BW! Dummy plate (package unit pcs) pcs 10

107 General clino Systems Additional Components 7120A j- 1B+ Programme selector for radio programmes Programme selector with fm supporting plate and expanding / retaining clamps suitable for fm backboxes. Class of protection IP 40, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 1 programme selector for radio programmes 88912H Cover plate for programme selector 88912H y I4@ Cover plate for programme selector Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plates (single) Mounting frame for cover plates (double) Mounting frame for cover plates (triple) 7120H j- 1IN Radio unit with volume control and headphone jack Radio unit with volume control and jack for connecting headphones, with fm supporting plate and expanding / retaining clamps for installation in fm backboxes. Class of protection IP 20, when installed incl. according cover plate Installation in flush mount box, DIN 4907 Installation depth 2 mm Dimensions (WxH) 71 x 71 mm 1 volume control 1 phone jack for connecting dynamic headphones 88912K Cover plate for radio unit 88912K y L4O Cover plate for radio unit Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 106

108 General clino Systems Additional Components 89760B zm 1CY Headphones with jack plug 1 Headphones for patient handset and radio unit with volume control. 2 1 adjustable headband 2 foam -padded earpieces 1.8 m connector cable Impedance 2 Ohm Capacity max. 0.1W Input voltage 0.0 W Transmission range 40 Hz - 1 Hz Weight 4 g 89760BZ Spare foam pads C zm 1D^ Earphones with right-angle plug Headphones with right-angle plug for connection to clino phon 99 patient handsets and clino com 21 patient handsets and terminals. Impedance Loading capacity Transmission Weight 2 Ohm max. 0.1 W 40 Hz - 1k Hz 4 g 1 adjustable headband 2 foam pads 1.8 m connection cable 1 stereo right-angle plug (. mm) 89760BZ Spare foam pads 74096D k* 7EM Cable fixing clip for mobile call units (attached to trapeze bar) Cable fixing clip for patient handsets and patient terminal (attached to trapeze bar) 10 pcs 71186GV h 7HWz Telephone interface unit for mm mounting rail Telephone interface unit with TAE 6N plug with time delay. For connection to telephone network (ZZF approved) as well as with a change-over contact. 20V AC power supply. Operating voltage 20 V AC Class of protection IP 40 Colour grey Dimensions (WxHxD) x 68 x 60 mm 107

109 General clino Systems Additional Components 7261A1 i` 2B2, Actuator unit AE20- ( contacts 20 V AC) Actuator unit for control of operations on the 20 V power supply system according to EM60669 Part (VDE062). In connection with the actuator unit, a maximum of light sources or other electric devices can be controlled via various terminal devices (i.e. patient terminal, patient handset, multiple push-button). The actuator unit is equipped with a separate input for an autarkic push-button (i.e. lamp push-button). The actuator unit is connected via the actuator databus (POF synthetic fiber) i.e. to the bed module or also the room terminal and controlled by this superordinate unit. Multiple actuator units can be cascadeconnected, so that a maximum of 7 switching contacts can be used. Installation surface, flush and cavity-wall mounting Colour white RAL 9016 PC + ABS - FR Class of protection IP 40 Connection lead max. 10 m (LWL) Operating voltage 20 V AC Contact load 20 V AC, A total Dimensions (LxWxH) 142 x 78. x 0. mm 8982B2 8982C2 fm backbox, double / triple Cavity wall backbox, double / triple 7261B1 i` 2C21 Actuator unit AE20-2 (2 mutually contacts 20 V AC) Actuator unit with 2 interlocking contacts for control of operations on the 20 V power supply system, specially designed for controlling motors i.e. blinds. In connection with the actuator unit, a maximum of 1 motor can be controlled via various terminal devices (i.e. patient terminal, patient handset, multiple push-button). The actuator unit is equipped with two separate inputs for autarkic push-buttons (i.e. control push-button). The actuator unit is connected via the actuator databus (POF synthetic fiber) i.e. with the bed module or also the room terminal and controlled by this superordinate unit. Multiple actuator units can be cascade-connected, so that a maximum of 7 switching contacts can be used. Installation surface, flush and cavity-wall mounting Colour white RAL 9016 PC + ABS - FR Class of protection IP 40 Connection lead max. 10 m (LWL) Operating voltage 20 V AC Contact load 20 V AC, A Dimensions (LxWxH) 142 x 78. x 0. mm 8982B2 fm backbox, double / triple 8982C2 Cavity wall backbox, double / triple 108

110 General clino Systems Additional Components 7261D1 i` 2E2; Actuator unit AE20-2 free (2 floating contacts) 1 Actuator unit with 2 floating contacts for control of operations up to 0 V AC/DC. The device s necessary control voltage has to be fed in externally. The contacts can be controlled via various terminal devices (i.e. patient terminal, patient handset, multiple push-button). Additionally, there are two separate inputs for autarkic push-buttons (i.e. control pushbutton) available. The actuator unit is connected via the actuator databus (POF synthetic fiber) i.e. to the bed module or also the room terminal and controlled by this superordinate unit. Multiple actuator units can be cascade-connected, so that a maximum of 7 switching contacts can be used. 2 4 Installation surface, flush and cavity-wall mounting Colour white RAL 9016 PC + ABS - FR Class of protection IP 40 Connection lead max. 10 m (LWL) Operating voltage 20 V AC Contact load 0 V (AC/DC), A Dimensions (LxWxH) 142 x 78. x 0. mm 8982B2 8982C2 fm backbox, double / triple Cavity wall backbox, double / triple 7261C1 i` 2D26 Actuator unit AE24- ( contacts 24 V DC) Actuator unit with contacts for control of operations at 24 V DC. In connection with the actuator unit, a maximum of contacts can be controlled via various terminal devices (i.e. patient terminal, patient handset, multiple push-button). The actuator unit is equipped with an input for autarkic push-buttons (i.e. control push-button). The actuator unit is connected via the actuator databus (POF synthetic fiber) i.e. to the bed module or also the room terminal and controlled by this superordinate unit. Multiple actuator units can be cascade-connected, so that a maximum of 7 switching contacts can be used. Installation surface, flush and cavity-wall mounting Colour white RAL 9016 PC + ABS - FR Class of protection IP 40 Connection lead max. 10 m (LWL) Operating voltage 24 V DC Contact load 24 V DC, A Dimensions (LxWxH) 142 x 78. x 0. mm 8982B2 8982C2 fm backbox, double / triple Cavity wall backbox, double / triple 8980K1 zv 1L20 Intermediate frame Intermediate frame with central insertion hole (ø 4 mm) for installation devices in accordance with DIN 4907, suitable for mounting frames. plastic moulding material Colour white - RAL 101 Dimensions (WxH) 69 x 69 mm 89849F1 fm cover frame single, white RAL

111 General clino Systems Additional Components 89849F1 zu :G29 Fm cover frame (single /101) Fm cover frame (single /101), suitable for cover plates and intermediate frames (69x69 mm). Colour Dimensions (WxHxD) ABS white - RAL 101 (F1) or white - RAL 9016 (F) 81 x 81 x 6, mm Installation 88914A y B4% Frame for cover plates (single) Colour white RAL 9016 PC + ABS - FR Dimensions (WxH) 81 x 81 mm 88914B y C4* Frame for cover plates (double) Colour white RAL 9016 Pc + ABS - FR Dimensions (WxH) 81 x 12 mm 88914C y D4/ Frame for cover plates (triple) Colour white RAL 9016 PC + ABS - FR Dimensions (WxHxD) 81 x 22 mm 8891A y 6B4) Surface mount base (single) Colour white RAL 9016 Dimensions 81 x 81 x 20.2 mm PC + ABS - FR 110

112 General clino Systems Additional Components 8891C y 6D4 Surface mount base (double) 1 Colour white RAL 9016 Dimensions (WxHxD) 8 x 16 x 20.1 mm zinc-coated sheet steel D y 6E48 Surface mount base (triple) Colour white RAL 9016 zinc-coated sheet steel Dimensions (HxWxD) 227 x 8 x 0 mm 88910B y 1C4 Standard plate Standard plate with insertion hole in accordance with DIN Colour white RAL 9016 PC + ABS - FR 88914A 88914B 88914C Mounting frame for cover plate (single) Mounting frame for cover plate (double) Mounting frame for cover plate (triple) 18971A 2B; Fm backbox Backbox in accordance with DIN 4907, suitable for all installation units with expanding / retaining clamps. Dimensions (ØxD) insulator 8 x 40 mm 18971B 2C@ Cavity wall backbox Cavity wall backbox for wood, plaster, and other cavity walls. Installation Dimensions (ØxD) thermoplastic, flame-retardant cente: 60 mm 71 x 6 mm 111

113 General clino Systems Additional Components 18972AV BWN Flush mount combination box with extruded plaster cover Flush mount combination box with extruded plaster cover for masonry with plaster adjustment (+ 1mm). Installation Dimensions (WxHxD) insulator centre: 60 mm 71 x 71 x mm 18976A 7BO Cavity wall combination box Combination box for cavity wall installation in wooden, plaster, and other cavity walls. Installation Dimensions (WxH) thermoplastic, flame resistant centre: 60 mm 81 x 71 mm 8982B2 z[ CB Fm backbox, double / triple 8982C2 z[ DG Cavity wall backbox, double / triple 88899A yz :B* Additional fastening for top-hat rail mounting Additional fastening for top-hat rail mounting the following devices: - zone control unit - paging interface unit - printer interface unit - PC interface unit - devices in the same housing 112

Product Catalogue Ackermann clino system 21

Product Catalogue Ackermann clino system 21 Product Catalogue 2007 Ackermann clino system 21 Content 1 General Details 2-4 Foreword 2 Abbreviations 2 Alarm Kit for Public Washrooms - 9 System Compact CL 6 System Manual 7 8-9 System 21 11-49 System

More information

Product Catalog Ackermann Clino Systems

Product Catalog Ackermann Clino Systems Product Catalog 0 Ackermann Clino Systems Contents General information Abbreviations / Ingress Protection Clino Systevo 6-0 System description System overview Application examples Central components Duty

More information

Operation Instructions

Operation Instructions Operation Instructions Configuration Module (Part No 72649B1) 84000JA 022011 GB Technical information is subject to change without notice! 2011 Honeywell International Inc Contents Abbreviations 3 General

More information

CATALOGUE D45 High performance door entry system

CATALOGUE D45 High performance door entry system CATALOGUE 2011 D45 High performance door entry system 2 INDEX General features 4 Devices 10 Software 18-19 Solution for multi-storey buildings 20 Solution for a building complex 21-22 Compatibility with

More information

signakom besser sicher

signakom besser sicher www..ch IP NWAAES0150 icall 100 IP-B Full IP address unit with blind cover and buzzer. Communication with Netrix message server. Includes integrated FTP-server and is remotely and individually programmable

More information

hospicall Call System hospicall P3 Catalogue 2016/17 Call systems in accordance with DIN VDE 0834 for hospitals, care homes and similar institutions

hospicall Call System hospicall P3 Catalogue 2016/17 Call systems in accordance with DIN VDE 0834 for hospitals, care homes and similar institutions hospicall Call System hospicall P3 Call systems in accordance with DIN VDE 0834 for hospitals, care homes and similar institutions Catalogue 2016/17 1 Since 2004 we have continued to develop for you as

More information

Figure 50. LED through-board connectors and guide marks

Figure 50. LED through-board connectors and guide marks 5.6.3 Installing the LED Lamp Boards on the IP Room Controller Board On the back side of the IP room controller PCB there are the four sets of through-board connections for the LED lamp boards. Each through-board

More information

hospicall Call System hospicall P3 Catalogue 2014/15 Call systems in accordance with DIN VDE 0834 for hospitals, care homes and similar institutions

hospicall Call System hospicall P3 Catalogue 2014/15 Call systems in accordance with DIN VDE 0834 for hospitals, care homes and similar institutions hospicall Call System hospicall P3 Call systems in accordance with DIN VDE 0834 for hospitals, care homes and similar institutions Catalogue 2014/15 1 Since 2004 we have continued to develop for you as

More information

D45. High performance door entry system CATALOGUE A Group Brand

D45. High performance door entry system CATALOGUE A Group Brand D45 CATALOGUE 2011 High performance door entry system A Group Brand 2 INDEX General features 4 Devices 10 Software 18-19 Solution for multi-storey buildings 20 Solution for a building complex 21-22 Compatibility

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

PRO700 EXCHANGELESS INTERCOM CRITICAL COMMUNICATION

PRO700 EXCHANGELESS INTERCOM CRITICAL COMMUNICATION PRO700 EXCHANGELESS INTERCOM CRITICAL CRITICAL Vingtor-Stentofon products are developed by the Zenitel Group and includes a range of high quality communications equipment and systems. Being in business

More information

SicuroLED-G - advantages

SicuroLED-G - advantages 6 SicuroLED-G - advantages For emergency lightings with external supply escape routes, areas with particular panic hazard, workplaces with particular people hazard and safety devices can be illuminated

More information

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply Emergency CATALOGUE Vol. 01 Lighting Decentralised and centralised supply Light is safety Light must be safe! Interior luminaire, exterior luminaire and emergency luminaire are all important to ensure

More information

LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE

LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE Fed up with your Internet access being restricted to a single room? Would you like access available in any room in the house that has a telephone socket? For

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

Product and functional description

Product and functional description Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect

More information

STENTOFON PRO700 ExchangElEss IntERcOm

STENTOFON PRO700 ExchangElEss IntERcOm STENTOFON PRO700 Exchangeless Intercom STENTOFON PRO700 exchangeless intercom Used daily by thousands of businesses, public service buildings and security companies throughout the world, there isn't a

More information

Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws.

Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws. APS-M1 Accessories Sensor System Analog Position Sensor Analog Position Sensor System Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws. Function

More information

AC5160 SiPass integrated controller kit

AC5160 SiPass integrated controller kit AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one

More information

EMS10 - EMS50. Cameo specification sheet. Product Description

EMS10 - EMS50. Cameo specification sheet. Product Description Product Description Wall Mount Fist Microphones 10, 20 or 50 Selection Buttons EN54 Compliant Indicators and Controls EN54 Fault List Display Speech Level VU Bargraph Fully Monitored Hardware Bypass Fallback

More information

Digital Intercom Stations DTM Series

Digital Intercom Stations DTM Series Digital Intercom Stations DTM Series Features and Functions Digital intercom stations for indoor use Different designs with up to 60 keys available DTM 110 with interface for handset connection LCD display

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Digital Outdoor Intercom Station DA/DAE 0x5 Series

Digital Outdoor Intercom Station DA/DAE 0x5 Series Digital Outdoor Intercom Station DA/DAE 0x5 Series Features and Functions Robust construction for use in harsh industrial environments Degree of protection IP66 Glass-fiber reinforced polyester Configurable

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System The issue of security is more than ever important.

More information

N-8000 SERIES IP INTERCOM SYSTEM

N-8000 SERIES IP INTERCOM SYSTEM N-8000 SERIES IP INTERCOM SYSTEM Cutting-edge TOA technology for greater versatility and improved sound quality IP Network-Compatible Intercom System with Packet Audio Technology The TOA N-8000 Packet

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety.

Switch cabinet housings. Distribution housings. Appropriate housings for each application. Our experience. Your safety. Switch cabinet housings Distribution housings Appropriate housings for each application Our experience. Your safety. Overview of the housing ranges Mounting rail bus system In-Rail Bus...6 Switch cabinet

More information

RCC45 ➁ Overview / /

RCC45 ➁ Overview / / RCC45 ➁ Overview 010.2936 More future and modularity Integration of POF and power Guaranteed modularity Long-term investment protection Flexible cabling solution Fast and convenient installation 1 010.2721

More information

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order #

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order # Digital Delegate Microphone Unit with Loudspeaker Order # 725.706 Supplied without gooseneck microphone FEATURES Coated plastic housing with metal bottom plate Inserts made of optically hardened acrylic

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

Clino System 99plus. Intelligent Life Care. Added value at the point of care simple, efficient and future-proof

Clino System 99plus. Intelligent Life Care. Added value at the point of care simple, efficient and future-proof Clino System 99plus Intelligent Life Care Added value at the point of care simple, efficient and future-proof Sustainable communication for health care environments Established communication technologies

More information

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

Surface-Mounting Product Ranges

Surface-Mounting Product Ranges Introduction Overview Light signals SCHUKO socket outlets Two-circuit switches Garages, laundry rooms, laboratories and workshops are often exposed to a lot of heavy-duty activity, which includes the odd

More information

Data logger systems from ROTRONIC

Data logger systems from ROTRONIC Data logger systems from ROTRONIC RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network Logger with power supply RS-485

More information

System telephone extension STE 30. User Manual

System telephone extension STE 30. User Manual System telephone extension STE 30 User Manual AGFEO System telephone extension STE30 Intended use The system telephone extension STE30 is intended for used in an AGFEO ISDN telecommunication system AS

More information

Electro Magnetic Compatibility (EMC)

Electro Magnetic Compatibility (EMC) Electro Magnetic Compatibility (EMC) This equipment complies with European rules for EMC according to EN5503, EN5500 and EN5008-. Operation is subject to the following two conditions: This device may not

More information

SI220 Sintony Intrusion Control Panel

SI220 Sintony Intrusion Control Panel SI220 Sintony Intrusion Control Panel for small and mid-sized businesses Multifunctional intrusion control panel Modular design Extensive assortment of functional modules Flexible configuration Communication

More information

AIAS. Technical description

AIAS. Technical description Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains AIAS - and Efficient Heating Demand Products Controlled Tunnel Ventilation Fans 1 / 4 AIAS Technical description 2 / 9 AIAS -

More information

VISOCALL IP. Product Catalogue.

VISOCALL IP. Product Catalogue. VISOCALL IP. Product Catalogue. . Table of Contents Table of Contents General... 4 Systemdescription... 5 1 Characteristic System Properties...5 2 The Communications Platform...6 3 Basic Installation...11

More information

Display Panel BAT 100 LSN. en Operation Guide

Display Panel BAT 100 LSN. en Operation Guide Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

User s manual. Easy Scan XT3 LED

User s manual. Easy Scan XT3 LED User s manual Easy Scan XT3 LED Table of content 1. Safety instructions... 3 2. Before you begin... 4 2.1. What is included... 4 2.2. AC Power... 4 3. Introduction... 4 3.1. Features... 4 4. Product overview...

More information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

- NLS NAVIGATION LIGHT CONTROL

- NLS NAVIGATION LIGHT CONTROL Technical documentation - NLS 3000 - NAVIGATION LIGHT CONTROL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition 0.2 29.09.2010 STO TK Changes

More information

Cisco ONS CL Shelf Assembly Hardware

Cisco ONS CL Shelf Assembly Hardware CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System Description The issue of security is more than ever

More information

Area of use The Provita wall rail system is suitable for use

Area of use The Provita wall rail system is suitable for use WALL RAILS GENERAL WALL RAILS Area of use The Provita wall rail system is suitable for use in normal wards in intensive care wards in pre-operation rooms in the recovery room in doctors surgeries. Due

More information

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved.

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved. LP-STAR Compact emergency lighting power supply with STAR technology Central overall fire protection section installation Advantages: One distributor for all emergency light circuits Central distributor

More information

Status display unit with P-bus connection

Status display unit with P-bus connection 8 917 DESIO TM I/O modules with P-bus connection PHM1.36TL for connections to automation stations with P-bus for status indication of up to 24 messages for remote control of up to 12 operating points in

More information

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.

Ethernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B. Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Cabling 4-poles B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Cabling 8-poles B.2 8 B.2 20 Cables B.2 90 Tools B.2 98 B 1 Profile

More information

MPS01. Paging and Emergency Microphone

MPS01. Paging and Emergency Microphone MPS01 Paging and Emergency Microphone EN54 Compliant Indicators and Controls Live, Store-and-Forward, and Recorded Message Broadcasts Silent No-Click PTT Button Speech Level VU Bargraph PA Zone Selection

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

Industrial Single-Port 10/100/1000Mbps 802.3bt PoE Injector (60 Watts, -40~75 degrees C, 48~56V DC)

Industrial Single-Port 10/100/1000Mbps 802.3bt PoE Injector (60 Watts, -40~75 degrees C, 48~56V DC) Industrial Single-Port 10/100/1000Mbps 802.3bt Injector (60 Watts, -40~75 degrees C, 48~56V ) Interface 2 RJ45 interfaces 1-port + output 1-port input 1 terminal block for master and slave power input.

More information

Accessories / 7XV5662

Accessories / 7XV5662 Accessories / XV Communication Converter XV-0AA00/GG for X. / RS / G.0. *) Fig. / Communication converter for X./ RS and G.0. The communication converter CC-XG for coupling to a communication network is

More information

Compact Intercom Server GE 100

Compact Intercom Server GE 100 Datasheet 1 2 Compact Intercom Server Compact and easy to put into operation, the Intercom Server also offers a variety of features. Like a modern PC, it is equipped with interfaces to other communication

More information

Technical System Catalogue CMC III Monitoring System

Technical System Catalogue CMC III Monitoring System Technical System Catalogue CMC III Monitoring System CMC III monitoring system CMC III Processing Unit 3 6 1 5 7 4 8 9 10 11 Computer Multi Control (CMC) is an alarm system for network and server enclosures,

More information

Products no longer available

Products no longer available Technical data sheet BKS24-.. MONICO-Controller BKS24-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Controller with application software for control and monitoring

More information

TeamConnect Ceiling Ceiling microphone conference system

TeamConnect Ceiling Ceiling microphone conference system 1/9 FEATURES Allows the person speaking to move around freely anywhere in the room during conferences and presentations Integrative Freedom: Virtually invisible integration thanks to unobtrusive design

More information

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order # Digital Flush Mount Delegate Microphone Unit Order # 725.722 Optional CA OL loudspeaker module, not included Table installation supplied without gooseneck microphone FEATURES High-quality flush mounting

More information

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit Product data sheet 94.040 EY-RU 341...346: Room operating unit, ecounit341...346 How energy efficiency is improved Individual setting of occupancy and absence as well as a room setpoint correction and

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series

HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series HiPath Cordless Office is the integrated cordless solution in the HiPath 500 and HiPath 3000 series for cordless communication with convenient

More information

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A) Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow

More information

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser. IP-3000 Series www.toa.com.hk IP Network Public Address System Monitoring and setting can be done easily by logging-in to control GUI via browser IP-3000 Series IP Network Public Address System Description

More information

HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series

HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series HiPath Cordless Office is the integrated cordless solution in the HiPath 500 and HiPath 3000 series for cordless communication with convenient

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual 10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter AMG9011G-H (-40 to 75C) User Manual www.amgsystems.com Content Overview...1 Introduction... 1

More information

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 430 FOUR CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 SIDE PANEL CONNECTORS...

More information

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems DCS 6000 User Manual Digital Conference System IT 6108 Infrared Transmitter Danish Interpretation Systems DIS Copyright 2003 Danish Interpretation Systems No part of this publication may be reproduced

More information

TrueCom. Building Communications Systems 5110-Series Controllers. UL Listed. Features. Operation. Description

TrueCom. Building Communications Systems 5110-Series Controllers. UL Listed. Features. Operation. Description TrueCom UL Listed Building Communications Systems 5110-Series Controllers Features Cost-effective Solid State Intercom Expandable to 120 Points Privacy and Pre-Announce Tones are User Selectable Telephone

More information

Voice Integration Overview

Voice Integration Overview Voice Integration Overview 010.2936 Intelligent voice integration Highest packing density Modular design Efficient and tool-free connection technique Comprehensive product range Ingenious labelling system

More information

Access control panel U-Prox IC E (Elevator control)

Access control panel U-Prox IC E (Elevator control) 1.003 Access control panel U-Prox IC E (Elevator control) Installation and programming manual About this document http://u-prox.com This manual covers installation, adjustment and use of U-Prox IC E (hereinafter

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position) echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.

More information

EY-RU 355: Room operating unit, ecounit355

EY-RU 355: Room operating unit, ecounit355 Product data sheet 1.1 94.041 EY-RU 355: Room operating unit, ecounit355 How energy efficiency is improved Individual setting of occupancy and absence as well as room setpoint correction, control of lights

More information

MCS 50. Discussion Control Unit. 1 of 7

MCS 50. Discussion Control Unit. 1 of 7 Discussion Control Unit FEATURES One microphone line for a maximum of 32 microphone units Integrated power supply unit with control for up to 32 microphone units Can be expanded to 64 microphone units

More information

ScreenLine Accessories MB model

ScreenLine Accessories MB model ScreenLine Accessories MB model ST2121 Control Module 1 group of blinds (PC configuration) control (Potential separated) Individually configurable via Configuration Utility (PC) DIN rail mounting Dim.:

More information

584 5WG AB_1 DELTA

584 5WG AB_1 DELTA Product DELTA profil DELTA style DELTA ambiente Display and control unit 5WG1 585-2AB01 pearl grey 5WG1 585-2AB11 titanium white 5WG1 585-2AB21 anthracite 5WG1 585-2AB71 silver 5WG1 585-2AB11 titanium

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System The issue of security is more than ever important.

More information

Central Battery System ZB-S Eaton, All Rights Reserved.

Central Battery System ZB-S Eaton, All Rights Reserved. Central Battery System ZB-S Central Battery System ZB-S Agenda New charging technology System Configuration Internal Modules External Modules Battery Management System PC Software CG Vision Date, Venue

More information

Specification Sheet: HT SERIES

Specification Sheet: HT SERIES Specification Sheet: HT SERIES HT Series: High Specification 19 Enclosures Hi-tech Series of 19 enclosures, supplied in self assembly (flat pack) format for ease of transportation and storage. Manufactured

More information

HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series

HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series HiPath Cordless Office for the HiPath 500 and HiPath 3000 Series HiPath Cordless Office is the integrated cordless solution in the HiPath 500 and HiPath 3000 series for cordless communication with convenient

More information

TECHNICAL DATA KM8RJ45. Industrial Outlet IP67/65. can be applied in the fields of industrial automation and building control.

TECHNICAL DATA KM8RJ45. Industrial Outlet IP67/65. can be applied in the fields of industrial automation and building control. TECHNICAL DATA The TrueNet industrial outlet from ADC KRONE allows the installation of RJ45 based Ethernet connections in extreme environmental conditions like industrial production facilities, outdoor

More information

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS MANUFACTURER REQUIREMENTS The Manufacturer of the equipment and provider of related services shall provide

More information

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET

INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET INDUSTRIAL ETHERNET SWITCHES WAGO Solutions at the Heart of the Industrial ETHERNET 1 Contents ETHERNET Switches ECO and Standard 3 4 SFP Modules Interface for Fiber-Optic 5 ETHERNET Switches Managed 6

More information

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The (master controller) and S 7000 (slave controller) control units are used to connect and control the GAT NET. Lock 7000 electronic

More information

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without

More information