GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000
|
|
- Lorraine Sherman
- 5 years ago
- Views:
Transcription
1 GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000 Application The (master controller) and S 7000 (slave controller) control units are used to connect and control the GAT NET. Lock 7000 electronic locker locks from GANTNER. The control units operate in online mode and communicate with a host PC/server. The master controller serves as the communication bridge between the host PC/server and the GAT NET. Controller S 7000 slave controllers. For system flexibility, different slave controllers are available to suit the leading RFID technologies (see order information). Functional description The correct type of slave controller must be used to suit the RFID technology in operation. The slave controllers are connected to the master controllers via a serial interface. Each master controller can control up to 8 slave controllers and 192 locks over a maximum cable length of 200 m. For smaller MIFARE /ISO systems, a light version of the slave and master controllers is available (see functionality table). In online operation, the slave controllers receive data carrier information via the connected locks. This information is sent via the master controller to the PC/server for authorization. The current status of the locker system is also forwarded to the PC/server, thereby allowing the status of each locker to be visualized using, for example, GANTNER PC software. An emergency mode function for online mode ensures operation continues if communication to the PC/server is temporarily interrupted. Highlights Connection of locks via industry-standard MOLEX plugs LED status display Simple configuration with GANTNER software tools Firmware update via host interface possible Diagnostic system for detecting lock problems Integration into alarm system (locker break-in alarm) Order information Description Master controller for max. 8 slave controllers Light Master controller for max. slave controllers, no relays and no optocouplers Light ext. Light extension license for max. 8 slave controllers F/ISO MIFARE /ISO 1569 slave control unit for max. 24 GAT NET.Lock 7000 electronic locks Part No Accessories Description Part No. F/ISO Light MIFARE /ISO 1569 slave control unit for max. 12 GAT NET.Lock 7000 electronic locks GAT NET.Lock 7000 Electronic locker lock 6854 B LEGIC slave controller for max. 24 GAT NET.Lock GAT NET.Lock Cable 5m 5 m connection cable for the GAT NET.Lock 7000, 4-pin MOLEX plug on both ends 7440 ICLS iclass slave control unit for max. 24 GAT NET.Lock GAT NET.Lock Cable Extension m m extension cable for the GAT NET.Lock 7000 GAT NET. 20V supply unit GAT NET. Cord xxx cord for power supply unit (EU), (UK), (AUS), 6685 (US), 6674 (D) GAT NET. Plug Plug to forward the power supply GAT Patch Kabel m, shielded Ethernet patch cable with 8-pin RJ45 plugs See description Controller functionality table (F/ISO) Number of relays Number of optocouplers Max. no. of slave units Max. no. of NET.Locks Master Standard Master Light Slave Standard Slave Light * (via slaves) 6 (via slaves) *expandable to 8 with additional license (Part No )
2 Technical data Nominal voltage UDC: supply unit: Reader types of slave control lers - F/ISO: - B: - ICLS: Maximum locks per slave controller: Maximum slave controllers per master controller: Memory (Master): 24 V External power supply units available (see order information) MIFARE + ISO 1569 LEGIC (Advant) HID iclass - Slave standard: 24 - Slave light: 12 - Master standard: 8 - Master light: * Internal memory for 10,000 bookings SD card slot for memory expansion, log files, firmware update or user lists Digital inputs (master controller): - Master standard: 4 - Master light: 0 Digital outputs (master contr.): - Master standard: 4 - Master light: 0 *expandable to 8 with additional license (Part No ) Interface to the locks: Interface betw. slave and master: Master and server: 1 Wire (special cable for supply and data signal) Ethernet Connectors: - Master to server (Ethernet): RJ 45 - Slave to master (): RJ 45 - Locks: MOLEX, type Micro-Fit.0 TM - : MOLEX Housing material: Plastic (ABS - V0) Dimensions: 10 mm x 1 mm x 42 mm (12.2 x 5.24 x 1.65 ) Permitted ambient temperature: 0 C to +60 C Protection type: IP 40 Protection class: Weight: Environment class based on VdS 2110: I Approx. 600 g II (conditions in indoor areas) Dimensions Light mm (5.24 ) Light mm (12.2 ) Typical application 2 1. GAT NET.Controller M/S 7000 (same housing for master and slave) 2. SD card slot. Ethernet interface for PC/server connection 4. Relay outputs 5. DC 24 V output 6. Digital optocoupler inputs 7. supply input (DC 24 V) 8. in-/output (for master / slave controller connection) 9. and buttons and status LEDs 10. GAT NET.Lock 7000 connection sockets to the server/host Ethernet Master Controller Master Controller + power + power Plug GAT NET.Lock 7000 Identification with RFID data carrier Lockers 2
3 Installation The GAT NET.Controller 7000 master and slave controllers must be installed in the vicinity of the connected GAT NET.Lock 7000 locks to keep cable lengths to a minimum. Usually the controllers are stored on top of the lockers. Although the permanent fixing of the controllers is not required, when a controller is to be permanently mounted, e.g., on a wall, use the screw holes provided in the base of the controller. The housing does not have to be opened for this process. Measurements for installation mm (10.65 ) 4.8 mm (0.19 ) 4.8 mm (0.19 ) 5.5 mm (0,22 ) Ø 4.8 mm (0.19 ) 0.5 mm (0.02 ) 1 mm (5.24 ) mm (6.09 ) mm (6.09 ) 09.6 mm (12.19 ) Installation process 1. Drill three mounting holes based on the measurements in the diagram above. Depending on the supporting surface, use the appropriate drill diameter for the screws and/or wall plugs (screws to max. M4). 2. Screw in the top two screws approximately half way.. Mount the controller housing on the top screws and push down until the housing stops against the screws. Tighten screws if necessary Screw the third screw into the bottom mounting hole and tighten firmly Ensure the controller is secured firmly and cannot be removed.
4 Electrical connections - GAT NET.Lock 7000 connections Note: The F/ISO Light has 12 lock connection ports and network connections to the GAT NET.Lock 7000 locks supply GAT NET. (or power plug - see description below) From master controller or from previous To the next GAT NET.Lock 7000 connections The locks are connected using a GAT NET.Lock Cable 5m (Part No. 7440). The 5 m cable can be extended using the GAT NET.Lock Cable Extension m (Part No ) or to max. 10 m using the GAT NET. Lock Connector (Part No ) and another GAT NET.Lock Cable 5m. The numbers on the determine the channel assignment for the locks. The GAT NET.Lock 7000 locks must not be connected to the GAT SMART.Controller S 7000! Network connections - bus connection to slave controllers via RJ 45 jacks. On the, connect the incoming line (server/master side) to the socket and the outgoing line (to next slave controller) to the socket. Recommended cabling : min. CAT 5 (STP), 200 m maximum cable length per line. LED signaling supply There are two possibilities for power supply: is connected to the MOLEX socket labeled. Use the supplied power supply unit (see technical data). 1. A power supply is connected to every in a line. 2. A power supply is connected to a few controllers that forward power on to the remaining controllers in the line. For the controllers that are not directly supplied, a power plug (see order information) must be plugged into the socket. Note: A power supply must always be connected to the first slave controller. If five or more slave controllers are used, the fifth controller must also be supplied in addition to the first controller. From master controller Plug yellow green - (yellow): Connection to the master controller - (green): communication active - (blue): Lock action - (green/red): Status information (see manual) for the line must be forwarded in the correct direction. Use the socket to continue supply to the next controller as shown above. Reset and mode buttons - : 1. Reset of controller (see manual) 2. Delete configuration = reset to default (see manual) - : Perform automatic antenna adjustment (see manual) 4
5 Electrical connections - Ethernet connection (to host) Note: The GAT.NET Controller M 7000 F/ISO Light does not have any relays or optocouplers and slave controller connections SLAVES ADD-ON Ethernet to host supply GAT NET. (or power plug - see description below) To the first Network connections - Ethernet to host via RJ 45 jacks. - bus connection to slave controllers via RJ 45 jacks m max. cable length per line. The must be connected to the SLAVES socket! Recommended cabling Ethernet: min. CAT 5 (STP) : min. CAT 5 (STP), 200 m max. cable length per line. LED signaling yellow SLAVES green ADD-ON supply is connected to the MOLEX socket labeled. Use the supplied power supply unit (see technical data). Note: For a tidy installation, the power supply can be stored in the designated slot in the bottom of the controller housing. The WEEE symbol on GANTNER products and their packaging indicates that the corresponding material must not be disposed of with normal household waste. Instead such marked waste equipment must be disposed of by handing it over to a designated electronic waste recycling facility. Separating and recycling this waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. Please contact your local authority for further details of your nearest electronic waste recycling facility. - (yellow): Connection to the slave controller - (green): communication active - (blue): For future use - (green/red): Status information (see manual) Reset and mode buttons - : 1. Reset of controller (see manual) 2. Delete configuration = reset to default (see manual) - : Reserved for future use Safety instructions - This device must be installed by qualified personnel only. - The applicable safety and accident prevention regulations must be observed. - Safety devices must not be removed. - Please observe the technical data of the device specified on the data sheet. - The device must be disconnected from the power supply prior to installation, assembly or dismantling. 5
GAT NET.Lock 7000 System Electronic RFID Locker Locks
Electronic RFID Locker Locks Installation, Configuration, Operation Document Version 3.0 www.gantner.com HB_GAT-NETLOCK7000--EN_30 1 2 HB_GAT-NETLOCK7000--EN_30 www.gantner.com Copyright 2013, GANTNER
More informationGAT LEISURE News May 2015
GAT GAT Relaxx Additional Information When using GAT SMART.Locks with GAT SMART.LockAxx, the Free Locker Mode can be selected as well. Checking of Certificate Not all devices automatically check the certificate.
More informationIF-80x Outdoor Terminal
95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationTechnical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B
Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationData logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.
Data logger Installation and operating instructions SOREL Connect Read carefully before installation, commissioning and operation 1.1. - Specifications Description of data logger Electrical specifications:
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationDisplay Panel BAT 100 LSN. en Operation Guide
Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationKey Switch. Document version: 1.5 (Updated 02 May 2017)
Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationKRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller. P/N: Rev 5
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller P/N: 2900-000691 Rev 5 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions
More informationInnoMedia Business VoIP ATA Models
InnoMedia Business VoIP ATA Models MTA8328-4, MTA8328-8, MTA8328-24 Quick Installation Guide Important Safety Instructions Protective Earthing Protective earthing is used as a safeguard. This equipment
More informationProduct Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.
Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection
More informationUSER MANUAL. RC-74DL Master Room Controller MODEL: P/N: Rev 4
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-74DL Master Room Controller P/N: 2900-000691 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions
More informationAccessories Bus Terminals
Accessories s Connectors Lightbus Z1000 Z1010 Z1020 standard connector for 1,000 µm plastic fibre standard connector for 200 µm PCS fibre coupling for Z1000 PROFIBUS ZB3100 ZB3101 ZB3102 ZS1031-3000 ZS1031-3500
More informationKRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers. P/N: Rev 5
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers P/N: 2900-300253 Rev 5 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions
More informationUSER MANUAL. RC-43T Remote Controller MODEL: P/N: Rev 3
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-43T Remote Controller P/N: 2900-300301 Rev 3 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions 3
More informationUSER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH
USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationTruVision IP Thermal Camera Installation Guide
TruVision IP Thermal Camera Installation Guide P/N 1073335-EN REV B ISS 19OCT17 Copyright Trademarks and patents Manufacturer Certification 2017 United Technologies Corporation, Interlogix is part of UTC
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationRST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND
More informationSPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0
SPA-ZC 17 Bus connection module User s manual and Technical description 1 2 3 4 5 6 7 8 O N SPA / RS 485 SPA 1100000 RS 485 0011110 SLAVE 1 MASTER 0 Tx SC Rx 2 5 Uaux 80...265 V ~ 18...80 V SPA-ZC 17 RS
More informationInstallation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010
Installation instructions RF-identification system with integrated AS-i slave UK DTSLF 704153 / 07 04 / 2010 Inhalt 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...4 2.1 General...4
More informationJUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet
sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous
More informationMC 11 EB-2 Power supply cabinet with external bus, AC version
MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures
More informationMultiturn absolute encoder
Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means
More informationRXTH DUAL ROOM SENSOR / SWITCH
DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE
More informationRXTP ROOM TEMPERATURE
ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4
More informationUser Manual EzLogger WiFi Ver 02
User Manual EzLogger WiFi Ver 02 Table of Contents 1 Symbols..................................... 01 2 Safety...................................... 02 3 Installation...................................
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationAS-i Safety Relay Output Module with Diagnostic Slave
AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this
More informationProduct and Function Description
Product and Function Description and the LED display. The touchscreen can be used to select from up to 6 languages for the display of texts and messages. The room temperature controller integrated in Contouch
More informationUSER MANUAL. RC-76R/RC-78R Room Controllers MODEL: P/N: Rev 2
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76R/RC-78R Room Controllers P/N: 2900-300253 Rev 2 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5
ILUMEN PID SOLUTION ILUMEN PIDBOX MINI INSTALLATION MANUAL INDOOR OUTDOOR Ilumen PIDbox mini Version 1.5 1 TABLE OF CONTENT 1 Information on this manual... 3 1.1 Validity... 3 1.2 Target group... 3 1.3
More informationR70 Ethernet to CAN interface Manual (1.4 EN)
R70 Ethernet to CAN interface Manual (1.4 EN) General information R70 Ethernet to CAN interface Manual Version 1.4 EN, 04/2009, DOC01816 Copyright 2009 by d&b audiotechnik GmbH; all rights reserved. d&b
More informationOperating Instructions VEGAMET 381
Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...
More informationTechnical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10
Model Number Features Solid shaft 0 Bit multiturn Free of wear magnetic sampling High resolution and accuracy Mechanical compatibility with all major encoders with fieldbus interface Status LEDs Description
More informationHUAWEI FT2260 Home Phone Connect Quick Start
HUAWEI FT2260 Home Phone Connect Quick Start Introduction Top View The figures are only for your reference, the actual shape and color of the product may differ slightly. 7 8 9 10 1 2 3 4 5 6 1 Power on/off
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationArtistic Licence. Mica. User Guide. Mica User Guide. Version 1-1
Artistic Licence Mica User Guide Version 1-1 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed
More informationExtension module for BACnet over Ethernet / IP and graphic Web functions
s 9 265 9263p01 DESIGO PX Extension module for BACnet over Ethernet / IP and graphic Web functions Plugs into the modular automation stations, type PXC...-U PXA30-W2 For operation of the PXC -U automation
More informationWireless door phone INSTALLATION AND USER S GUIDE. Ed V11 AG 651 AG 652
Wireless door phone 651 652 INSTALLATION AND USER S GUIDE AG 651 AG 652 0681 Ed. 02-06 V11 Before starting using the handset, put the handset on charge during about ten hours. Without this complete charge,
More informationIP-Bridge Module for establishing IP connections in 2-wire-based cablings
-Bridge Module for establishing connections in 2-wire-based cablings Third-party integration Compact size Flexible integration Ethernet for 2-wire networks The -Bridge provides an ideal, cost-efficient
More informationUSB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3104 4-Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3104. Please read this guide thoroughly. This document applies
More informationiloq S10 Online Configuration Guide
iloq S10 Online Configuration Guide Document version: 1.5 (Updated 02 May 2017) Contents 1 S10 Online System... 3 1.1 Printable Documentation... 4 1.2 Licenses...4 1.3 Net Bridge N100...4 1.3.1 Net Bridge
More informationFigure 50. LED through-board connectors and guide marks
5.6.3 Installing the LED Lamp Boards on the IP Room Controller Board On the back side of the IP room controller PCB there are the four sets of through-board connections for the LED lamp boards. Each through-board
More informationLCS² Cat. 6A RJ45 Socket
87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Céliane TM Page 1. General characteristics....1 2. Presentation...1 3. Installation...1 4. Technical characteristics...1
More informationFiber optic converter audio and CAN TA OPERATION MANUAL
Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.
More informationD Issue D Original. Instruction Manual. Micro Tool Interface
Instruction Manual D373-60-880 Issue D Original Micro Tool Interface Description SPI Micro-TIM MCM Micro-TIM TEL Micro-TIM SEMI E73 Micro-TIM LAM Alliance Micro-TIM Novellus C3 Micro-TIM Hitachi Micro-TIM
More informationDome Camera. Hardware Manual Z81, Z /01/08
Dome Camera Hardware Manual Z81, Z82 2018/01/08 Table of Contents Precautions 3 Regulatory Compliance... 4 Safety and Compliance Information... 5 Introduction 7 List of Models... 7 Package Contents...
More informationInstalling and Configuring Rialto Analytic Appliances
Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation
More informationUSER MANUAL RC-76M/RC-712M MODEL: P/N: Rev 3
KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RC-76M/RC-712M P/N: 2900-300329 Rev 3 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions 3 2.3 Recycling
More informationIB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B
INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area Data Sheet 5764B 09/2000 # % $ This data sheet is only valid in association with the INTERBUS Inline System Manual IB IL SYS
More informationPower supply module, bus connection module
s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can
More informationDC-D4213RX DC-D4213WRX
Network Camera Quick Guide DC-D4213RX DC-D4213WRX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationAS-i Safety Relay Output Module with Diagnostic Slave
AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationUSB 3.1 CAT6A/7 EXTENDER
USER MANUAL ICU504A USB 3.1 CAT6A/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM Power Mode Config Status Link Video USB 2 USB 3 Power Mode Config Status Link Video USB 2 USB 3 TABLE OF CONTENTS PRODUCT OPERATION
More informationVISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:
Technical Documentation VISY-Output 8 8-Channel relay output module Version: 3 Edition: 2016-09 Art. no.: 350072 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07 0 Fax:
More informationVE8012A/VE8012AR DUAL NETWORKED STATION PORT
ISSUE 3 VE8012A/VE8012AR DUAL NETWORKED STATION PORT INTRODUCTION The VE8012A/VE8012AR Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.
More informationRTD-NET Installation Instructions
LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND
More informationADC7520 SERIES. 1600W Battery Chargers and Power Supplies
ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave
More informationUser Manual TL-TP70-HDC 70m HDBaseT Extender Set for HDMI, RS232 & IR All Rights Reserved Version: TL-TP70-HDC _160926
User Manual TL-TP70-HDC 70m HDBaseT Extender Set for HDMI, RS232 & IR All Rights Reserved Version: TL-TP70-HDC _160926 Preface Read this user manual carefully before using this product. Pictures shown
More informationDEEP SEA ELECTRONICS PLC
DEEP SEA ELECTRONICS PLC DSE857 Configuration Suite PC Software and Operator Manual Document Number: 057-219 Author: Tony Manton DSE857 Configuration Suite PC Software and Operator Manual ISSUE 1 DSE857
More informationOperating and mounting instructions
General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore
More informationInstallation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A
Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights
More informationDISCLAIMER Whilst every effort has been made
PUBLISHED BY Gallagher Group Limited Kahikatea Drive, Private Bag 3026 Hamilton, New Zealand www.gallagherams.com Copyright Gallagher Group Limited 2010. All rights reserved. Gallagher SmartReader R Series
More informationACS-8-System. Access Control. Performance features at a glance
ACS-8-System Access Control The ACS-8 is an access control system which is modular in construction and highly autonomous. A particularly noteworthy performance feature is the flexible and freely-selectable
More informationOperating instructions
www.lehmann-locks.com GB L033-A01 L033-A02 M300 L033-A01 / -A02 Operating instructions Contents Page General description / Technical data / Safety instructions... 2 Care and maintenance / Factory settings
More informationTruVision Series 4 IP Camera Installation Guide
TruVision Series 4 IP Camera Installation Guide P/N 1073195-EN REV D ISS 24AUG16 Copyright Trademarks and patents Manufacturer Certification 2016 United Technologies Corporation, Interlogix is part of
More informationDSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND
More informationCAN 300 PRO, Communication Module
90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB
More informationProduct and functional description
Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The
More informationStrato Pi Touch Display User Guide
Strato Pi Touch Display User Guide July 2016 Revision 002 a professional touch panel computer based on Raspberry Pi 3 Introduction 3 Features 4 Usage and connections 5 Hardware installation 5 µsd installation
More informationRAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description
I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless
More informationPlug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs
1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector
More informationF3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K
F3102 / F3107 / F3110 / F3115 / F3210 / F3215 86085K3000020 PN: 86085K3000030 Zavio F3102/F3107/F3110/F3115/F3210/F3215 Quick Installation Guide Please follow the installation steps below to set up F3102
More informationTEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018
TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018 00. CONTT 01. SAFETY INSTRUCTIONS INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. PRODUCT PRODUCT PROFILE TECHNICAL PARAMETERS 03. INSTALLATION PRODUCT
More informationRXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications
s 3 856 Desigo RXC Room controller RXC39.5 Communicating room controller for fan-coil applications The RXC39.5 room controller is used for temperature control in individual rooms. For fan-coil systems
More information9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)
echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More informationDomino DFWEB. DFWEB: interface module between Domino bus and Ethernet network with Web-Server function. Module Connection. Domino
: interface module between bus and Ethernet network with Web-Server function module has been developed to be used in all applications of system where it is required to control the domotic system through
More information2 in 1 LAN Tester and Multimeter Model:
2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured
More informationSIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No
SIMADYN D Digital Control System User Manual Fiber-Optic Rack Coupling CS12 Edition 05.95 DK No. 237741 User Manual, Fiber-Optic Rack Coupling CS12 Edition Status 1 Fiber-Optic Rack Coupling CS12 05.95
More informationActive Distributors AS-i Safety, Active Distributors AS-i
Active Distributors Safety, Active Distributors x connectors for Periphery connection via, M cable sockets or push in terminals (Figure similar) Figure Type Inputs Safety, SIL, Cat. x 9 mm, -channels Safety
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationExtension module for graphic Web functions for one automation station
s 9 266 9263p01 DESIGO PX Extension module for graphic Web functions for one automation station Plugs into the modular automation stations, type PXC...-U For operation of the PXC -U automation stations
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationCommunication module to connect M-bus devices to POL6xx.xxx controllers.
s 3 936 Climatix TM Climatix communication M-Bus module POL907.00/xxx Communication module to connect M-bus devices to POL6xx.xxx controllers. The POL907.00/xxx communication module offers the following
More informationInstallation of the PCMeasure Movement Sensor (30114)
1. Hardware: Installation of the PCMeasure Movement Sensor (30114) Connect the sensor to a serial or parallel port of the PC using one of the PCMeasure adaptors, or directly to the PCMeasure Ethernet Box.
More informationPOE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from
POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible
More informationGSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18
GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58
More informationTXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O
s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point
More information