PowerFlex 40 Configured AC Drives

Size: px
Start display at page:

Download "PowerFlex 40 Configured AC Drives"

Transcription

1 Installation Instructions PowerFlex 0 onfigured A Drives atalog Numbers B

2 Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Labels may also be on or inside the equipment to provide specific precautions. SHOK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. AR FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE)., Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

3 Table of ontents Preface Who Should Use this Manual? What Is Not in this Manual Additional Resources Manual onventions General Precautions ompliance ertification atalog Number Explanation PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter Standard Features Enclosure Options NEMA/UL Type (Position, ode D) NEMA/UL Type X (Position, ode ) ommunication Options DeviceNet (Position, ode D) EtherNet/IP (Position, ode E) PROFIBUS (Position, ode P) ontrolnet (Position, ode ) Power Disconnect Options Drive Motor ircuit Protector (Position +, ode P) Drive Motor ircuit Protector (Position +, ode PT) Drive Input Fused Disconnect Switch (Position +, ode P).. Drive Input Fused Disconnect Switch (Position +, ode PT) Operator Device Options Hand/Off/Auto Selector Switch (Position +, ode S) Auto/Manual Selector Switch (Position +, ode S) Start and Stop Push Buttons (Position +, ode S) Forward/Reverse Selector Switch (Position +, ode S) Local Speed Potentiometer (ode S) Local ontrol Off/Run Forward and Local/Remote Selector Switches (ode S0) Local/Off/Remote Selector Switch With One Normally Open Interposing Relay (ode S) Spring Return Hand-Off-Auto Selector Switch (ode S) lear Fault Push Button (ode S) Quick Disconnects DeviceNet Quick Disconnect - Bottom (ode E) DeviceNet Quick Disconnect - Left Side (ode E) I/O Options DeviceNet I/O ( In/ Out) w/spring Return HOA and Power Disconnect Aux. ontact (Position +, ode R)..... DeviceNet Point I/O w/ib ( Inputs) (Position +, ode R) DeviceNet I/O ( In/ Out) w/spring Return HOA, Power Disconnect Aux. ontact, and I/O Quick Disconnects (Position +, ode R) Rockwell Automation Publication B-IN00K-EN-P - September 0

4 Table of ontents hapter ontrol Wiring Overview ontrol Wiring Overview Schematic Drawings hapter Mechanical Installation Mounting onsiderations Environment Maximum Ambient Air Temperature Minimum Mounting learances Dimensions Layout Drawings Appendix A Specifications Specifications Tables Appendix B Replacement Parts Spare Parts Lists Rockwell Automation Publication B-IN00K-EN-P - September 0

5 Preface The purpose of this manual is to provide basic information needed to install PowerFlex 0 Adjustable Frequency A Standard onfigured Drives. User documentation for the PowerFlex 0 Standard onfigured Drives includes these Installation Instructions and the PowerFlex 0 User Manual, publication B-UM00. Both manuals are required to properly install and operate PowerFlex 0 Adjustable Frequency A Standard onfigured Drives. For information on See page Who Should Use this Manual? What Is Not in this Manual Additional Resources Manual onventions General Precautions ompliance ertification atalog Number Explanation Who Should Use this Manual? This manual is intended for qualified personnel. You must be able to program and operate adjustable frequency A drives. In addition, you must have an understanding of the parameter settings and functions. What Is Not in this Manual The PowerFlex 0 onfigured A Drives Installation Instructions is designed to provide only basic installation and operation information. For this reason, the following topics have not been included: Troubleshooting Start-Up Programming and Parameters Please refer to the PowerFlex 0 Adjustable Frequency A Drive User Manual, publication B-UM00, for detailed drive information. Rockwell Automation Publication B-IN00K-EN-P - September 0

6 Preface Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Wiring and Grounding Guidelines for Pulse Width Modulated (PWM) A Drives, publication DRIVES-IN00 Preventive Maintenance of Industrial ontrol and Drive System Equipment, publication DRIVES-TD00 Safety Guidelines for the Application, Installation and Maintenance of Solid State ontrol, publication SGI-. Guarding Against Electrostatic Damage, publication PowerFlex 0 Adjustable Frequency A Drive User Manual, publication B-UM00 Industrial Automation Wiring and Grounding Guidelines, publication 0-. Product ertifications website, Description Provides basic information needed to properly wire and ground PWM A drives. Provides a checklist that may be used as a guide in performing preventive maintenance on variable frequency drives. Provides general guidelines for the application, installation, and maintenance of solid-state control. Provides practices for guarding against Electrostatic damage (ESD). Provides basic information needed to install, start-up and troubleshoot the PowerFlex 0 A drive. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at To order paper copies of technical documentation, contact your local distributor or Rockwell Automation sales representative. For Drives Technical Support: Title Drives Technical Support Online at Manual onventions To help differentiate parameter names and LD display text from other text, the following conventions will be used: Parameter Names will appear in [brackets]. For example: [D Bus Voltage]. Display Text will appear in quotes. For example: Enabled. The following words are used throughout the manual to describe an action: Word an annot May Must Shall Should Should Not Meaning Possible, able to do something Not possible, not able to do something Permitted, allowed Unavoidable, you must do this Required and necessary Recommended Not recommended Rockwell Automation Publication B-IN00K-EN-P - September 0

7 Preface General Precautions ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts and assemblies. Static control precautions are required when installing, testing, servicing or repairing this assembly. omponent damage may result if ESD control procedures are not followed. If you are not familiar with static control procedures, reference A-B publication , Guarding Against Electrostatic Damage or any other applicable ESD protection handbook. ATTENTION: An incorrectly applied or installed drive can result in component damage or a reduction in product life. Wiring or application errors, such as, under sizing the motor, incorrect or inadequate A supply, or excessive ambient temperatures may result in malfunction of the system. ATTENTION: Only qualified personnel familiar with adjustable frequency A drives and associated machinery should plan or implement the installation, start-up and subsequent maintenance of the system. Failure to comply may result in personal injury and/or equipment damage. ATTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged before performing any work on the drive. Measure the voltage at the drive (Refer to the PowerFlex 0 User Manual for test point locations). The voltage must be zero. ompliance ertification ertifications are applicable to approved program defined options. U.S./anada UL: UL0 UL: AN/SA-. No. Please refer to the PowerFlex 0 Adjustable Frequency A Drive User Manual, publication B-UM00, for additional information. Rockwell Automation Publication B-IN00K-EN-P - September 0

8 Preface atalog Number Explanation The PowerFlex 0 Adjustable Frequency A Standard onfigured Drives catalog numbering scheme is shown below. Position B D P0 D 0 N N P a b c d e f g h i j Drive ode Type B PowerFlex 0 Voltage Rating ode Voltage Ph. D 0V ac a b c Amp Rating 0V 0Hz Input ode Amps kw (Hp) P. 0. (0.) P. 0. (.0) P0.0. (.0) P0.0. (.0) (.0) 0. (.) 0. (0) 0 () d Enclosure ode Enclosure NEMA/UL Type X D NEMA/UL Type The design of the PowerFlex 0 Standard onfigured Drive supports indoor and outdoor applications that are not in direct sunlight. Emission lass ode Rating 0 Not Filtered f g Version ode Version RS (Standard) ontrolnet D DeviceNet E EtherNet/IP P PROFIBUS DP ode N ode N e HIM ode Interface Module Fixed Keypad on Drive Fixed Keypad on Drive and LD Display with Digital Speed ontrol F HIM on Enclosure Door (-HIM-S) This option changes the enclosure rating to indoor only. h i Rating Reserved Rating Reserved j Options ode Description -E DeviceNet Quick Disconnect (Bottom) -E DeviceNet Quick Disconnect (Left Side) -P Motor ircuit Protector -PT Motor ircuit Protector (ustomer wiring into top of device) -P Disconnect Switch - Fused -PT Disconnect Switch - Fused (ustomer wiring into top of device) DeviceNet I/O ( In/ Out) w/spring -R Return HOA and Power Disconnect Aux. ontact -R DeviceNet Point I/O w/ib ( Inputs) -R -R plus I/O Quick Disconnects and () V D Receptacle -S Hand/Off/Auto S.S. (Start/Stop/Speed Ref.) -S Auto/Manual S.S. (Speed Ref.) -S Start and Stop P.B. -S Forward/Reverse S.S. -S Door Mounted Local Speed Pot (- Turn) -S0 Local/Remote and Local ontrol Off/Run Forward Selector Switches -S Local/Off/Remote with N.O. Interposing Relay -S Spring Return Hand/Off Auto S.S. (Start/Stop/Speed Ref.) -S lear Fault P.B. Rockwell Automation Publication B-IN00K-EN-P - September 0

9 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options For information on See page Standard Features Enclosure Options 0 ommunication Options Power Disconnect Options Operator Device Options Quick Disconnects I/O Options This chapter describes the standard features and operation for PowerFlex 0 Standard onfigured Drives and associated options. Standard Features This package integrates the Standard PowerFlex 0 drive. The PowerFlex 0 drive can be used for Volts per hertz or Sensorless Vector applications and offers an Autotune feature allowing the drive to adapt to individual motor characteristics. The PowerFlex 0 is assembled in an enclosure which includes the following features. NEMA/UL Type /X - indoor and outdoor applications other than direct sunlight. () Flange mount drive/external heatsink reducing overall enclosure size. Mounting feet - orientation is adjustable per customer requirements. If required, the drive can be removed from the front of the enclosure for ease of assembly or repair. Low cost, highly configurable I/O inputs and/or 0-0V/-0 ma outputs that are not used by program standard features and options are available for customer use. () The enclosure does not normally protect electrical equipment from condensation, corrosion or contamination, which may occur within the enclosure or enter via the conduit or unsealed openings. Users must make adequate provisions to safeguard against such conditions, and satisfy themselves that the equipment is properly protected. For further information on criteria associated with NEMA enclosure ratings, refer to NEMA standards Publication No. 0-. When optional Door Mounted HIM is supplied, enclosure is rated indoor only. See enclosure options for specific enclosure style quoted. Rockwell Automation Publication B-IN00K-EN-P - September 0

10 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options Enclosure Options NEMA/UL Type (Position, ode D) The enclosure provided is a NEMA/UL Type, painted mild steel, which supports both NEMA/UL Type and NEMA/UL Type applications. Type enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, and hose directed water, and to be undamaged by the formation of ice on the enclosure. They are designed to meet hose-down, dust, and external icing and rust resistance design tests. Doors and openings will be gasket sealed. There are no ventilation openings within the enclosure to allow for free exchange of inside and outside air. Note: If optional Door Mounted HIM is not supplied, the design of the PowerFlex 0 Standard onfigured Drive supports indoor and outdoor applications that are not in direct sunlight. NEMA/UL Type X (Position, ode ) The enclosure provided is a NEMA/UL Type X. The material is type 0 stainless steel. Type X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose directed water, and to be undamaged by the formation of ice on the enclosure. They are designed to meet hose-down, dust, and external icing and rust resistance design tests. Doors and openings will be gasket sealed. There are no ventilation openings within the enclosure to allow for free exchange of inside and outside air. Note: If optional Door Mounted HIM is not supplied, the design of the PowerFlex 0 Standard onfigured Drive supports indoor and outdoor applications that are not in direct sunlight. 0 Rockwell Automation Publication B-IN00K-EN-P - September 0

11 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter ommunication Options DeviceNet (Position, ode D) The DeviceNet option is drive mounted and consists of the DeviceNet communication adaptor (-OMM-D) and adaptor cover (B-B for frame B drives or B- for frame drives). When DeviceNet is present, no other communication option is available other than the HIM. When used as a slave, the HIM will have limited functionality. For details related to the DeviceNet option, refer to the PowerFlex DeviceNet Adapter User Manual, publication OMM-UM00. To review this schematic see Figure on page and Figure on page 0. EtherNet/IP (Position, ode E) The EtherNet/IP option is drive mounted and consists of the EtherNet/IP communication adaptor (-OMM-E) and adaptor cover (B-B for frame B drives or B- for frame drives). When EtherNet/IP is present, no other communications option is available other than the HIM. When used as a slave, the HIM will have limited functionality. For details related to the EtherNet/IP option, refer to the PowerFlex EtherNet/IP Adapter User Manual, publication OMM-UM00. To review this schematic see Figure on page and Figure on page 0. PROFIBUS (Position, ode P) The PROFIBUS option is drive mounted and consists of the PROFIBUS communication adaptor (-OMM-P) and adaptor cover (B-B for frame B drives or B- for frame drives). When PROFIBUS is present, no other communication option is available other than the HIM. When used as a slave, the HIM will have limited functionality. For details related to PROFIBUS option, refer to the PowerFlex PROFIBUS Adapter User Manual, publication OMM-UM00. To review this schematic see Figure on page and Figure on page 0. ontrolnet (Position, ode ) The ontrolnet option is drive mounted and consists of the ontrolnet communication adaptor (-OMM-) and adaptor cover (B-B for frame B drives or B- for frame drives). When ontrolnet is present, no other communication option is available other than the HIM. When used as a slave, the HIM will have limited functionality. For details related to ontrolnet option, refer to the PowerFlex ontrolnet Adapter User Manual, publication OMM-UM00. To review this schematic see Figure on page and Figure on page 0. Rockwell Automation Publication B-IN00K-EN-P - September 0

12 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options Power Disconnect Options Drive Motor ircuit Protector (Position +, ode P) The Drive Motor ircuit Protector option is factory installed and provides a manual means of disconnecting input power to the drive. The bulletin 0M switch is designed to meet short circuit requirements for branch circuit protection. The rotary style handle is padlockable in On or Off position. See Table for the short circuit withstand rating of this option. Over load protection is supplied by the drive not the motor circuit protector. Incoming customer supplied power cables terminate at terminals R, S, T (L, L, L) located on the bottom of the device. omponent Specifications Switch Handle Bulletin 0M, 0V, see Table for short circuit withstand rating To be used only with grounded wye neutral A distribution systems -pole, Rod operated UL listed, E Approved, SA ertified Rotary style handle through the door, Door interlocked Padlockable in On or Off position, Defeatable in the On position IP (Type R,,,, X) Drive Motor ircuit Protector (Position +, ode PT) The Drive Motor ircuit Protector option is factory installed and provides a manual means of disconnecting input power to the drive. The bulletin 0M switch is designed to meet short circuit requirements for branch circuit protection. The rotary style handle is padlockable in On or Off position. See Table for the short circuit withstand rating of this option. Over load protection is supplied by the drive not the motor circuit protector. Incoming customer supplied power cables terminate at terminals R, S, T (L, L, L) located on the top of the device. omponent Specifications Switch Handle Bulletin 0M, 0V, see Table short circuit withstand rating To be used only with grounded wye neutral A distribution systems -pole, Rod operated UL listed, E Approved, SA ertified Rotary style handle through the door, Door interlocked Padlockable in On or Off position, Defeatable in the On position IP (Type R,,,, X) Table - Drive Option P and PT Short ircuit Withstand Ratings Drive Rating Option P / PT Short ircuit Withstand Rating 0.,,,,., 0, and HP ka HP 0 ka Rockwell Automation Publication B-IN00K-EN-P - September 0

13 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter Drive Input Fused Disconnect Switch (Position +, ode P) The Drive Input Fused Disconnect Switch option is factory installed and provides a manual means of disconnecting input power to the drive. The Allen- Bradley Bulletin R switch is designed to meet disconnect switch requirements for branch circuit protection. The rotary style handle is padlockable in On or Off position. This option has a 00 ka short circuit withstand rating. lass J fuses are supplied with the disconnect switch. Incoming customer supplied power cables terminate at terminals R, S, T (L, L, L) located on the bottom of the device. omponent Specifications Switch Handle A-B Bulletin R, 00V, 00 ka short circuit withstand rating Integral class J fuses, aptive terminal clamps -pole, Rod operated UL listed, E Approved, SA, ASTA, and LOVAG ertified Rotary style handle through the door, Door interlocked Padlockable in On or Off position, Defeatable in the On position True switch status indication IP (Type R,,,, X) Drive Input Fused Disconnect Switch (Position +, ode PT) The Drive Input Fused Disconnect Switch option is factory installed and provides a manual means of disconnecting input power to the drive. The Allen- Bradley Bulletin R switch is designed to meet disconnect switch requirements for branch circuit protection. The rotary style handle is padlockable in On or Off position. This option has a 00 ka short circuit withstand rating. lass J fuses are supplied with the disconnect switch. Incoming customer supplied power cables terminate at terminals R, S, T (L, L, L) located on the top of the device. omponent Specifications Switch Handle A-B Bulletin R, 00V, 00 ka short circuit withstand rating Integral class J fuses, aptive terminal clamps -pole, Rod operated UL listed, E Approved, SA, ASTA, and LOVAG ertified Rotary style handle through the door, Door interlocked Padlockable in On or Off position, Defeatable in the On position True switch status indication IP (Type R,,,, X) Rockwell Automation Publication B-IN00K-EN-P - September 0

14 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options Main Fuses (F-F) ATTENTION: Most codes require that upstream branch circuit protection be provided to protect input power wiring. Install the fuses recommended in Table. Do not exceed the fuse ratings. Failure to observe this precaution could result in damage to, or destruction of, the equipment. Input line branch circuit protection fuses must be used to protect the input power lines. If input fuses are not provided with your drive, recommended fuse values are shown in Table. The input fuse ratings listed in Table are applicable for one drive per branch circuit. No other load may be applied to that fused circuit. The recommended fuse type for all PowerFlex 0 Standard onfigured Drives is UL lass J. Table - Branch Fusing Voltage Rating Drive Rating HP Fuse Rating Amps 0V A Rockwell Automation Publication B-IN00K-EN-P - September 0

15 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter Input Power Wiring Refer to the PowerFlex 0 User Manual for additional detailed information about input power wiring recommendations and selection. ATTENTION: Protect the contents of the options cabinet from metal chips and other debris while drilling the conduit openings. Failure to observe this precaution could result in damage to, or destruction of, the equipment. ATTENTION: Do not route signal and control wiring with power wiring in the same conduit. This can cause interference with drive operation. Failure to observe this precaution could result in damage to, or destruction of, the equipment. To connect A input power to the drive package:. Select the proper wire size according to NE and all applicable local codes and standards. Note that you must punch openings in the Option abinet of the desired conduit size, following NE and all applicable local codes and standards. Power terminal block specifications are listed in Table.. onnect the three-phase A input power leads (three-wire VA) to the appropriate terminals. onnect the A input power leads to terminals L, L, L on the fused disconnect switch or motor circuit protector. Note: Drive Input Fused Disconnect Switch (-P) and Drive Motor ircuit Protector (-P) options are bottom fed. Drive Input Fused Disconnect Switch (-PT) and Drive Motor ircuit Protector (-PT) options are top fed.. Tighten the A input terminal power terminals to the proper torque according to drive type as shown in Table. Table - omponent urrent Ratings and Wire Sizing PowerFlex 0 SPD Drive Rating - 0V HP ontinuous urrent Rating Amps Factory Power Wire Size ()() mm ( AWG). 0. mm ( AWG) mm (0 AWG) ustomer Terminal Wire Size.. mm ( AWG).. mm ( AWG)..0 mm ( AWG) Operating Torque. N m ( lb in). N m ( lb in). N m ( lb in) () Wire is Black Hypalon. () Maximum/minimum sizes that the terminal block will accept - these are not recommendations. Rockwell Automation Publication B-IN00K-EN-P - September 0

16 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options Output Power Wiring Refer to the PowerFlex 0 User Manual for additional detailed information about output power wiring recommendations and selection. ATTENTION: Unused wires in conduit must be grounded at both ends to avoid a possible shock hazard caused by induced voltages. Also, if a drive sharing a conduit is being serviced or installed, all drives using this conduit should be disabled to eliminate the possible shock hazard from cross-coupled motor leads. Failure to observe these precautions could result in bodily injury. ATTENTION: Do not route signal and control wiring with power wiring in the same conduit. This can cause interference with drive operation. Failure to observe this precaution could result in damage to, or destruction of, the equipment. To connect A output power wiring from the drive to the motor:. Wire the three-phase A output power motor leads by routing them according to the drive option type. Note that you must punch openings in the option cabinet of the desired conduit size, following NE and all applicable local codes and standards. Power terminal block specifications are listed in Table. Do not route more than three sets of motor leads through a single conduit. This will minimize cross-talk that could reduce the effectiveness of noise reduction methods. If more than three drive/motor connections per conduit are required, shielded cable must be used. If possible, each conduit should contain only one set of motor leads.. onnect the three-phase A output power motor leads to terminals U, V, W (T, T, T) on the power terminal block located on the drive.. Tighten the three-phase A output power terminals to the proper torque according to drive type as shown in Table. Table - A Output Power Terminal Block Specifications Frame Maximum Wire Size () Minimum Wire Size Recommended Torque B. mm (0 AWG). mm ( AWG).. N m ( lb in). mm ( AWG). mm ( AWG).. N m ( lb in) () Maximum/minimum sizes that the terminal block will accept - these are not recommendations. Rockwell Automation Publication B-IN00K-EN-P - September 0

17 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter Operator Device Options Hand/Off/Auto Selector Switch (Position +, ode S) Speed Reference This 00F door mounted operator device is factory installed and provides a Hand/Off/Auto selector switch. The Hand/Off/Auto selector switch will start the drive in Hand mode and stop the drive in Off mode. In Auto mode the drive will be stopped and started from remote contact closures. In all cases, the Stop input to the drive must be present before the drive will start. The Hand/Off/Auto selector switch also determines the source of the actual drive speed reference. In Hand mode, speed source is parameter A0 [Preset Freq ]. In Auto mode, speed source is parameter A0 [Preset Freq ]. If the door mounted speed potentiometer (Option S) is supplied and it is intended to be the speed reference in Hand mode, set parameter A0 [Digital In Sel] to option 0V In trl. Refer to the table below and the PowerFlex 0 User Manual, publication B-UM00, for other options. Hand/Off/Auto Selector Switch (ode S) Parameter Settings Hand Mode Auto Mode P0 [Speed Reference] A0 [Digital In Sel] A0 [Digital In Sel] Preset Speed Preset Speed Preset Freq Preset Freq Preset Freq Analog Input (0-0V) Preset Freq 0V In trl Preset Freq Analog Input (-0mA) Preset Freq 0mA In trl Preset Freq ommunication Port () Preset Freq omm Port Preset Freq Speed Pot (Door) Preset Speed Preset Freq Preset Freq 0V In trl Analog Input (-0mA) Preset Freq 0mA In trl 0V In trl ommunication Port () Preset Freq omm Port 0V In trl HIM (Door) Preset Speed Preset Freq Preset Freq omm Port Analog Input (0-0V) Preset Freq 0V In trl omm Port Analog Input (-0mA) Preset Freq 0mA In trl omm Port () ommunication port will have both logic and reference control. omponent Specifications Bulletin 00F Devices IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum Hand/Off/Auto position, Maintained Selector Switch N.O. contacts Legend Plate 0 x 0 mm, Black with white lettering Wiring 0. mm ( AWG), Blue Schematics Figure on page, Figure on page This option is not compatible with odes R, R, S, S, S0, S or S. Rockwell Automation Publication B-IN00K-EN-P - September 0

18 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options Speed Reference Auto/Manual Selector Switch (Position +, ode S) This 00F door mounted operator device is factory installed and provides an Auto/Manual selector switch. The Auto/Manual selector switch determines the source of the actual drive speed reference. Using -wire control in Auto mode, speed source is parameter A0 [Preset Freq ]. In Manual mode, the speed source is parameter A0 [Preset Freq ]. If the door mounted speed potentiometer (Option S) is supplied and it is intended to be the speed reference in Manual mode, set parameter P0 [Digital In Sel] to option 0V In trl. Refer to the table below and the PowerFlex 0 User Manual, publication B-UM00, for other options. Auto/Manual Selector Switch (ode S) Parameter Settings Manual Mode Auto Mode P0 [Speed Reference] A0 [Digital In Sel] A0 [Digital In Sel] Preset Speed Preset Speed Preset Freq Preset Freq Preset Freq Analog Input (0-0V) Preset Freq 0V In trl Preset Freq Analog Input (-0mA) Preset Freq 0mA In trl Preset Freq ommunication Port () Preset Freq omm Port Preset Freq Speed Pot (Door) Preset Speed Preset Freq Preset Freq 0V In trl Analog Input (-0mA) Preset Freq 0mA In trl 0V In trl ommunication Port () Preset Freq omm Port 0V In trl HIM (Door) Preset Speed Preset Freq Preset Freq omm Port Analog Input (0-0V) Preset Freq 0V In trl omm Port Analog Input (-0mA) Preset Freq 0mA In trl omm Port () ommunication port will have both logic and reference control. omponent Specifications Bulletin 00F Devices Auto/Manual Selector Switch IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum position, Maintained N.. contact 0 x 0 mm, Black with white lettering 0. mm ( AWG), Blue Legend Plate Wiring Schematics Figure on page, Figure on page, Figure on page This option is not compatible with odes R, R, S, S0, S or S. Rockwell Automation Publication B-IN00K-EN-P - September 0

19 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter Start and Stop Push Buttons (Position +, ode S) This option provides factory installed 00F Start and Stop push buttons. In all cases, the Stop input to the drive must be present before the drive will start. Using -wire control, speed source is parameter A00 [Preset Freq 0]. The Stop push button may also be used as a fault reset. omponent Specifications Bulletin 00F Devices IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum Start Push Button Flush head, Green, N.O. contact Stop Push Button Extended head, Red, N.. contact Legend Plate 0 x 0 mm, Black with white lettering Wiring 0. mm ( AWG), Blue Schematics Figure on page, Figure on page, Figure 0 on page This option is not compatible with odes R, R, S, S0, S, S or S. Forward/Reverse Selector Switch (Position +, ode S) This 00F door mounted operator device is factory installed and provides a Forward/Reverse selector switch. When configured for -wire control, the drive will start when the selector switch is set to Forward. When the selector switch is set to Reverse, the drive will run in reverse. If the selector switch is operated while the drive is running, a change of direction command will occur. If the drive is stopped and the selector switch is operated, a change of direction command will occur. The speed source is parameter P00 [Preset Freq 0]. When configured for -wire control (ode S with S), the selector switch only changes direction. The drive is started and stopped via the Start and Stop push buttons (ode S). omponent Specifications Bulletin 00F Devices Forward/Reverse Selector Switch Legend Plate Wiring IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum -Wire: position, Maintained, N.O. & N.. contacts -Wire: position, Maintained, N.. contact 0 x 0 mm, Black with white lettering 0. mm ( AWG), Blue Schematics -Wire ontrol: Figure on page, Figure on page, Figure on page -Wire ontrol: Figure 0 on page This option is not compatible with odes R, R, S0 or S. Rockwell Automation Publication B-IN00K-EN-P - September 0

20 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options Local Speed Potentiometer (ode S) This option provides a factory installed 00F door mounted one turn potentiometer for speed control. The device provides the speed source when no digital inputs are active. When this option is provided, it becomes the speed source for the Hand mode of the Hand/Off/Auto selector switch (Option S) and the Manual mode of the Auto/Manual selector switch (Option S). omponent Specifications Bulletin 00F Devices IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified Screw terminals, 0.. mm ( AWG) maximum Speed Potentiometer -turn, 0k,.W, 00V Legend Plate 0 x 0 mm, Black with white lettering Wiring 0. mm ( AWG), Blue Schematic Figure on page 0 This option is not compatible with odes R-R. Local ontrol Off/Run Forward and Local/Remote Selector Switches (ode S0) This option provides two factory installed 00F door mounted selector switches. The Local/Remote selector switch determines the source of the start, stop, speed and direction commands. In Local mode, the factory default setting for parameter P0 [Speed Reference] = Preset Freq. In Remote mode, the factory default setting for parameter A0 [Digital In Sel] = omm Port. The Off/Run Forward selector switch allows the drive to be started and stopped when in Local ontrol. omponent Specifications Bulletin 00F Devices Local ontrol Off/Run Forward Selector Switch Local/Remote Selector Switch Legend Plate Wiring IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum position, Maintained, N.O. contact position, Maintained, N.O. contact 0 x 0 mm, Black with white lettering 0. mm ( AWG), Blue Schematic Figure on page This option is not compatible with odes R, R, S, S, S, S, S or S. 0 Rockwell Automation Publication B-IN00K-EN-P - September 0

21 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter Local/Off/Remote Selector Switch With One Normally Open Interposing Relay (ode S) This 00F door mounted operator device and interposing relay option is factory installed and provides a Local/Off/Remote selector switch. The Local/Off/Remote selector switch will start the drive in Local mode and stop it in Off mode. In Remote mode, the drive will be stopped and started from the factory installed R contact which is energized by a customer supplied and protected 0V A source. In all cases, the Stop input to the drive must be present before the drive will start. In both Local and Remote modes, the speed source is parameter A00 [Preset Freq 0]. omponent Specifications Bulletin 00F Devices IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum Local/Off/Remote position, Maintained, N.O. contacts Selector Switch Interposing ontrol Relay relay, 0 amp, 0V A coil, Octal base Legend Plate 0 x 0 mm, Black with white lettering Wiring 0. mm ( AWG), Blue Schematic Figure on page This option is not compatible with odes R, R, S, S, S, S, S0 or S. Rockwell Automation Publication B-IN00K-EN-P - September 0

22 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options Spring Return Hand-Off-Auto Selector Switch (ode S) This 00F door mounted operator device is factory installed and provides a Hand/Off/Auto selector switch. The Hand position is equipped with a spring return. The Hand/Off/Auto selector switch will start the drive while held in Hand mode and stop the drive in Off mode. The selector switch has a spring return disallowing the operator to remain in Hand. In Auto mode the drive will be stopped and started from remote contact closures. In all cases, the Stop input to the drive must be present before the drive will start. The Hand/Off/Auto selector switch also determines the source of the actual drive speed reference. In Hand mode, speed source is parameter A0 [Preset Freq ]. In Auto mode, speed source is parameter A0 [Preset Freq ]. If the door mounted speed potentiometer (Option S) is supplied and it is intended to be the speed reference in Hand mode, set parameter A0 [Digital In Sel] to option 0V In trl. Spring Return HOA Selector Switch (ode S) Speed Reference Parameter Settings Hand Mode Auto Mode P0 [Speed Reference] A0 [Digital In Sel] A0 [Digital In Sel] Preset Speed Preset Speed Preset Freq Preset Freq Preset Freq Analog Input (0-0V) Preset Freq 0V In trl Preset Freq Analog Input (-0mA) Preset Freq 0mA In trl Preset Freq ommunication Port () Preset Freq omm Port Preset Freq Speed Pot (Door) Preset Speed Preset Freq Preset Freq 0V In trl Analog Input (-0mA) Preset Freq 0mA In trl 0V In trl ommunication Port () Preset Freq omm Port 0V In trl HIM (Door) Preset Speed Preset Freq Preset Freq omm Port Analog Input (0-0V) Preset Freq 0V In trl omm Port Analog Input (-0mA) Preset Freq 0mA In trl omm Port () ommunication port will have both logic and reference control. omponent Specifications Bulletin 00F Devices IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum Hand/Off/Auto Selector position, Hand (spring return), Off, Auto (maintained), N.O. contacts Switch: Legend Plate 0 x 0 mm, Black with white lettering Wiring 0. mm ( AWG), Blue Schematic Figure on page This option is not compatible with odes R, R, S, S, S, S0 or S. Rockwell Automation Publication B-IN00K-EN-P - September 0

23 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter lear Fault Push Button (ode S) This option provides a factory installed 00F lear Fault push button. omponent Specifications Bulletin 00F Devices IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum lear Fault Push Button: Flush head, Black, N.O. contact Legend Plate 0 x 0 mm, Black with white lettering Wiring 0. mm ( AWG), Blue Schematic Figure on page This option is not compatible with ode S. Quick Disconnects DeviceNet Quick Disconnect - Bottom (ode E) A Brad Harrison, pin, bulkhead, male receptacle is provided and wired to the drive mounted DeviceNet module. The connector is located through the bottom of the enclosure providing a quick disconnect. This option is designed to enhance the DeviceNet offering (Position, ode D) and is not compatible with options,, E, P (Position ), or E. To review schematic refer to Figure on page. To review layout refer to Figure on page. For NEMA/UL Type or less stringent environments, the outer connector construction is made of plastic designed to withstand washdown conditions. DeviceNet Quick Disconnect - Left Side (ode E) A Brad Harrison, pin, bulkhead, male receptacle is provided and wired to the drive mounted DeviceNet module. The connector is located through the left side of the enclosure providing a quick disconnect. This option is designed to enhance the DeviceNet offering (Position, ode D) and is not compatible with options,, E, P (Position ), or E. To review schematic refer to Figure on page. To review layout refer to Figure on page. For NEMA/UL Type or less stringent environments the outer connector construction is made of plastic designed to withstand washdown conditions. Rockwell Automation Publication B-IN00K-EN-P - September 0

24 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options I/O Options DeviceNet I/O ( In/ Out) w/spring Return HOA and Power Disconnect Aux. ontact (Position +, ode R) This option provides a factory installed 00F door mounted operator device, a 00-DNYR and a power disconnect auxiliary contact mounted internal to the cabinet. The Hand/Off/Auto selector switch will start the drive while held in the Hand mode and stop it in the Off mode. The default speed reference comes from parameter P0, option (Preset Freq). The selector switch has a spring return disallowing the operator to remain in Hand. When in Auto the default speed reference is derived parameter A0, option (Preset Freq). The 00-DNYR is powered by DeviceNet and provides control based on customer control parameters. This option is prewired with an auto contact from the Hand/Off/Auto selector switch between the I/O V+ and IN0 terminals. The main power disconnect auxiliary contact is wired between the I/O V+ and IN terminals indicating if the disconnect is on or off. Two inputs and two outputs are available for customer use. omponent Specifications Bulletin 00F Devices Hand/Off/Auto Selector Switch Legend Plate Wiring 00-DNYR Schematic Figure on page IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum position, Hand (spring return), Off, Auto (maintained) N.O. & N.. contacts 0 x 0 mm, Black with white lettering 0. mm ( AWG), Blue culus Listed, SA, E DeviceLogix, Rotary address switches V D or 0V A inputs High-apacity transistor or Relay outputs ODVA ompliance v.0 Tested Power Disconnect Auxiliary ontact N.O. & N.. Side mounted contacts This option must be used with the drive mounted DeviceNet option D (Position ) and is not compatible with options R, R, S, S, S, S, S0, S or S. The drive mounted DeviceNet and the 00-DNYR will appear as separate nodes on the communication system. Rockwell Automation Publication B-IN00K-EN-P - September 0

25 PowerFlex 0 Standard onfigured Drive Standard Features and Options hapter DeviceNet Point I/O w/ib ( Inputs) (Position +, ode R) This option provides a factory installed -ADNX Point I/O Scanner in combination with a -IB ( input) four point, V D sink input. The drive DeviceNet is prewired to the subnet connector of the -ADNX. The customer is required to make the DeviceNet connection directly to the -ADNX network connector. The -IB is connected via a backplane offering four available inputs for customer use. The Point I/O Scanner allows data to be gathered from the drive mounted DeviceNet and the -IB ( input) appear as one node on the communication system. Refer to publication -IN0 for more detail on the -IB. omponent Specifications -ADNX Devices IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum -IB Devices Refer to publication -IN0 Schematic Figure on page This option must be used with the drive mounted DeviceNet option D (Position ) and is not compatible with options,, E, P (Position ), R, or R. Note: ustomer is required to supply external V D/A to power - ADNX scanner. Rockwell Automation Publication B-IN00K-EN-P - September 0

26 hapter PowerFlex 0 Standard onfigured Drive Standard Features and Options DeviceNet I/O ( In/ Out) w/spring Return HOA, Power Disconnect Aux. ontact, and I/O Quick Disconnects (Position +, ode R) This option provides a factory installed 00F door mounted operator device, a 00-DNYR mounted internal to the cabinet, a power disconnect auxiliary contact, four I/O quick disconnects, and a V D male receptacle. The Hand/Off/Auto selector switch will start the drive while held in the Hand mode and stop it in the Off mode. The default speed reference comes from parameter P0, option (Preset Freq). The selector switch has a spring return disallowing the operator to remain in Hand. When in Auto the default speed reference is derived parameter A0, option (Preset Freq). The 00-DNYR is powered by DeviceNet and provides control based on customer control parameters. The inputs and outputs are powered by customer supplied V D. This options is prewired with an auto contact from the Hand/Off/Auto selector switch between the I/O V+ and IN0 terminals. The main power disconnect auxiliary contact is wired between the I/O V+ and IN terminals indicating if the disconnect is on or off. The four I/O quick disconnects allow the customer to quickly connect to the remaining two inputs and outputs that are available for customer use. omponent Specifications Bulletin 00F Devices Hand/Off/Auto Selector Switch Legend Plate Wiring 00-DNYR Receptacle Shell onnector Insert ontacts Schematic Figure 0 on page IE style, Internationally rated Meet IP/IP and NEMA/UL Type /X/ UL Listed, SA ertified 0 amp contacts Screw terminals, 0.. mm ( AWG) maximum position, Hand (spring return), Off, Auto (maintained) N.O. & N.. contacts 0 x 0 mm, Black with white lettering 0. mm ( AWG), Blue culus Listed, SA, E DeviceLogix, Rotary address switches V D or 0V A inputs High-apacity transistor or Relay outputs ODVA ompliance v.0 Tested Power Disconnect Auxiliary ontact N.O. & N.. Side mounted contacts Black anodized machined aluminum Nylon Machined brass with gold over nickel plating This option must be used with the drive mounted DeviceNet option D (Position ) and is not compatible with options R, R, S, S, S, S, S0, S or S. The drive mounted DeviceNet and the 00-DNYR will appear as separate nodes on the communication system. Rockwell Automation Publication B-IN00K-EN-P - September 0

27 hapter ontrol Wiring Overview For information on See page ontrol Wiring Overview Schematic Drawings This chapter describes the control and signal wiring connection options. ontrol Wiring Overview Refer to the PowerFlex 0 User Manual for additional detailed information about control and signal wiring. The ontrol I/O Terminal Block (TB) and Relay Terminal Block (TB) located on the drive Main ontrol Board provide terminals for interfacing customer supplied control inputs and outputs. All analog and discrete control wiring will be made at these terminals. To connect control and signal wiring to the drive package:. Wire the control and signal leads by routing them according to the drive option type. Note that you must punch openings in the option cabinet of the desired conduit size, following NE and all applicable local codes and standards. I/O terminal block specifications are listed in Table. ontrol and signal wires should be separated from power wires by at least 0. meters ( foot).. onnect the control and signal wiring to the I/O terminals located on the drive.. Tighten the I/O terminals to the proper torque according to drive type as shown in Table. Table - I/O Terminal Block Specifications Voltage Rating Maximum Wire Size () Minimum Wire Size Torque 0 0V A. mm ( AWG) 0. mm ( AWG) N m (. lb in) () Maximum/minimum sizes that the terminal block will accept - these are not recommendations. Rockwell Automation Publication B-IN00K-EN-P - September 0

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

Kinetix 6000 Axis Module and Shunt Module

Kinetix 6000 Axis Module and Shunt Module Installation Instructions Kinetix 6000 and Shunt Module Catalog Numbers 2094-AMxx, 2094-BMxx 2094-AMxx-S, 2094-BMxx-S 2094-BSP2 Topic Page About This Publication 1 Important User Information 2 Before You

More information

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer Installation Instructions PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer Catalog Number 6189V-2PCI15R Topic Page About This Publication 1 Important User Information 2 Safety

More information

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Installation Instructions Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout Catalog Numbers 2711-NR5T, 2711P-RAT12E2 Topic Page About This Publication 1 Important User Information 2 About

More information

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual. DriveGuard Safe-Off Option for PowerFlex 70 AC Drives User Manual www.abpowerflex.com Important User Information Solid state equipment has operational characteristics differing from those of electromechanical

More information

PowerMonitor 5000 Unit Catalog Number Upgrade

PowerMonitor 5000 Unit Catalog Number Upgrade Installation Instructions PowerMonitor 5000 Unit Catalog Number Upgrade Catalog Numbers 1426-MxE-xxx Topic Page Upgrade the Device Catalog Number with the ControlFLASH Utility 3 Determine Communication

More information

Differential Liquid/Gas Pressure Transmitter

Differential Liquid/Gas Pressure Transmitter Installation Instruction Differential Liquid/Gas Pressure Transmitter Catalog Number(s) 1414-CPZ10FWFAA, 1414-IPZ10FWFAA Explosion Hazard WARNING Do not use in an explosive or hazardous environment, with

More information

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC Software Start-Up and Reference Manual D2-3416-2 GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, 30-100 HP, 230V AC Version 6.04 Important User Information Solid-state equipment has operational

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1771-OBN Series B) Use this document as a guide when installing the catalog number 1771-OBN series B output module. Because of the variety of uses for the products described

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-OD) This document provides information on: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

Application Guide. Considerations for 32 Bit Integer Parameters in 16 Bit Processors. PowerFlex 700VC, PowerFlex 700S. Introduction.

Application Guide. Considerations for 32 Bit Integer Parameters in 16 Bit Processors. PowerFlex 700VC, PowerFlex 700S. Introduction. Topic: Drive Product: Introduction User Information Considerations for 32 Bit Integer Parameters in 16 Bit Processors PowerFlex 700VC, PowerFlex 700S An Application Guide provides generic information on

More information

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit Installation Instructions PowerFlex 755 Common DC Input Drives, Frames 8...10 Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit Catalog Numbers 20G14x, 21G14x Topic Page General Precautions

More information

Installation Instructions

Installation Instructions Installation Instructions Cat. No. 1771 P3, P4, P5 and P5E Use this document as a guide when installing the catalog number 1771-P3, -P4, -P5 or -P5E power supplies. Because of the variety of uses for the

More information

PanelView 600 Terminals

PanelView 600 Terminals Installation Instructions PanelView 600 Terminals Catalog Numbers 2711-K6Cxx, 2711-B6Cxx Topic Page Hazardous Location Considerations 3 European Union Directive Compliance 4 Wiring and Safety Guidelines

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

Kinetix 300 Memory Module Programmer

Kinetix 300 Memory Module Programmer Kinetix 300 Memory Module Programmer Catalog Number 2097-PGMR Topic About the Memory Module Programmer 1 Parts List 3 Batteries Operation 4 Using Memory Module Programmer 6 Switch On/Off Memory Module

More information

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board Installation Instructions PowerFlex DC Drive Frame B Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,

More information

InView Communication Modules

InView Communication Modules Installation Instructions InView Communication Modules Catalog Numbers 2706-PxM, 2706-PxK, 2706-PxP Topic Page About This Publication 1 Important User Information 2 Power Supply Requirements 3 Mount the

More information

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

GuardLogix: TLS Guardlocking Application

GuardLogix: TLS Guardlocking Application Safety Application Example GuardLogix: TLS Guardlocking Application Safety Rating: PLd, Cat. 3 to EN ISO 13849.1 2008 Introduction... 2 Important User Information... 2 General Safety Information... 3 Description...

More information

ArmorPoint I/O Field Potential Distributor, Series A

ArmorPoint I/O Field Potential Distributor, Series A Installation Instructions ArmorPoint I/O Field Potential Distributor, Series A (Cat. No. 1738-FPD) The field potential distributor (Cat. no. 1738-FPD) lets you change the field power distribution source

More information

CompactLogix Power Supplies Specifications

CompactLogix Power Supplies Specifications Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,

More information

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Safety Application Example Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller Light Curtain with On-machine Components Safety Rating: Category

More information

GuardLogix: Safety Gate Application with SensaGuard Switch

GuardLogix: Safety Gate Application with SensaGuard Switch Safety Application Example GuardLogix: Safety Gate Application with SensaGuard Switch Safety Rating: PLe, Cat. 4 to EN ISO 13849.1 2008 Introduction...2 Important User Information...2 General Safety Information...3

More information

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller Safety Application Example Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller Guardlocking with On-machine Components Safety Rating: Category 3, according to EN954-1

More information

InView Firmware Update

InView Firmware Update Installation Instructions InView Firmware Update Topic Page Hazardous Voltage 3 Change EPROM on 2706-P72, 2706-P74 Display 3 Change EPROM on 2706-P42, 2706-P44 Displays 5 Firmware Upgrade Kit 7 2 InView

More information

PowerMonitor 1000 Unit Catalog Number Upgrade

PowerMonitor 1000 Unit Catalog Number Upgrade Installation Instructions PowerMonitor 1000 Unit Catalog Number Upgrade Catalog Numbers 1408-UPT1-E3, 1408-UPT2-E3, 1408-UPE1-E3, 1408-UPE2-E3, 1408-UP485-ENT, 1408-UPT3-E3 Topic Important User Information

More information

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch Safety Application Example GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch Safety Rating: PLd, Cat. 3 to EN ISO 13849.1 2008 Introduction... 2 Important User Information...

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

For additional PowerFlex 4M data and general drive information, refer to the following publications:

For additional PowerFlex 4M data and general drive information, refer to the following publications: Product Overview Providing users with powerful motor speed control in a compact, space saving design, the Allen-Bradley PowerFlex 4M AC drive is the smallest and most cost effective member of the PowerFlex

More information

Teaching Color-Sensing Connected Components Building Block. Quick Start

Teaching Color-Sensing Connected Components Building Block. Quick Start Teaching Color-Sensing Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 71-A1B, -A2B, -A3B, -A3B1, -A4B Series B) Because of the variety of uses for the products described in this publication, those responsible for the application and use

More information

ControlLogix SIL2 System Configuration

ControlLogix SIL2 System Configuration ControlLogix SIL2 System Configuration Using RSLogix 5000 Subroutines Application Technique (Catalog Numbers 1756 and 1492) Important User Information 8 / 2011 Solid state equipment has operational characteristics

More information

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1

More information

Allen-Bradley Motors

Allen-Bradley Motors Installation Instructions Firmware Update Instructions for Ethernet, Enhanced and ControlNet PLC-5 Programmable Controllers Purpose Firmware Update Kit Contents Hardware and Software Requirements This

More information

Application Technique. Safety Function: Safety Camera with E-stop

Application Technique. Safety Function: Safety Camera with E-stop Application Technique Safety Function: Safety Camera with E-stop Products: Guardmaster Dual-input Safety Relay, Guardmaster SC300 Safety Camera Safety Rating: PLd, Cat. 3 to EN ISO 13849-1: 2008 2 Safety

More information

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon Allen-Bradley PLC-5 Backup Communication Module User Manual (1785-BCM, 1785-BEM) product icon Important User Information Because of the variety of uses for this product and because of the differences between

More information

Embedded I/O Expansion Board with 10 Outputs

Embedded I/O Expansion Board with 10 Outputs Installation Instructions Embedded I/O Expansion Board with 10 Outputs Catalog Number 1799-OQ10X Topic Page Important User Information 2 Environment and Enclosure 3 About the Board 4 Install the Board

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

160 AA02SF1 AF DS-D17

160 AA02SF1 AF DS-D17 Ordering Instructions The Standard Packaged Drive Program allows users to create drive packages based on their specific needs. A complete drive package may be specified by assembling a single catalog number

More information

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS SECTION 26 29 13.16 PART 1 - GENERAL 1.1 THE REQUIREMENT A. General: The CONTRACTOR shall provide solid-state reduced voltage motor starters, complete and operable, in accordance with the Contract Documents.

More information

5504 Thermocouple Analog Input Module

5504 Thermocouple Analog Input Module 550 Thermocouple Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

1395 Node Adapter Board Troubleshooting

1395 Node Adapter Board Troubleshooting 1395 Node Adapter Board Troubleshooting Specifications Electrical: Board power provided by Drive (+5V) Discrete Input 24V DC or 115V AC, jumper selectable Environmental: Ambient Operating Temperature Storage

More information

Product Description. Table of Contents

Product Description. Table of Contents Product Providing users with easy installation in mechanical fan and pump systems, the Allen-Bradley PowerFlex 400 AC drive offers a wide range of built-in features allowing for seamless building system

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

NHP SAFETY REFERENCE GUIDE

NHP SAFETY REFERENCE GUIDE NHP SAFETY REFERENCE GUIDE GSR SAFETY FUNCTION DOCUMENTS SensaGuard Non-contact Interlock Switch with E-stop Table of Contents: Important User Information 45 General Safety Information 45 Introduction

More information

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication Remote I/O Scanner Catalog Number 1747-SN Installation Instructions 2 Remote I/O Scanner Important User Information Because of the variety of uses for the products described in this publication, those

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

DeviceNet ArmorBlock Network Powered 16-input Module

DeviceNet ArmorBlock Network Powered 16-input Module Installation Instructions DeviceNet ArmorBlock Network Powered 16-input Module Catalog number 1732D-IBDPM12MND, Series A Table of Contents Topic Page Important User Information 2 Environment and Enclosure

More information

Color-Sensing Connected Components Building Block. Quick Start

Color-Sensing Connected Components Building Block. Quick Start Color-Sensing Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

DeviceNet ArmorBlock Network Powered 16-input Module, Series A

DeviceNet ArmorBlock Network Powered 16-input Module, Series A Installation Instructions DeviceNet ArmorBlock Network Powered 16-input Module, Series A Catalog Number 1732D-IB161212D Topic Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic

More information

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2

More information

GV3000/SE AC Drive 1-20 HP, 230V AC

GV3000/SE AC Drive 1-20 HP, 230V AC Hardware Reference, Installation, and Troubleshooting Manual D2-3388-5 GV3000/SE AC Drive - 20 HP, 230V AC Version 6.04 Important User Information Solid-state equipment has operational characteristics

More information

Contents. Conformity to Standards. Allen-Bradley 1

Contents. Conformity to Standards. Allen-Bradley 1 The Bulletin 160 is a microprocessor controlled adjustable frequency drive designed for reliable control of three-phase induction motors. The drive produces a three-phase, PWM, adjustable frequency output

More information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All

More information

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8

More information

Migration Guide. Bulletin 160 SSC Variable Speed Drives to PowerFlex 525 AC Drives

Migration Guide. Bulletin 160 SSC Variable Speed Drives to PowerFlex 525 AC Drives Migration Guide Bulletin 160 SSC Variable Speed Drives to PowerFlex 525 AC Drives Important User Information Read this document and the documents listed in the additional resources section about installation,

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

DeviceNet ArmorBlock Network and Auxiliary Powered I/O Module

DeviceNet ArmorBlock Network and Auxiliary Powered I/O Module Installation Instructions DeviceNet ArmorBlock Network and Auxiliary Powered I/O Module Catalog Number 1732D-8X81212D Topic Page Important User Information 2 Environment and Enclosure 3 Prevent Electrostatic

More information

GV3000/SE AC Drive HP, 230V AC

GV3000/SE AC Drive HP, 230V AC Hardware Reference, Installation, and Troubleshooting Manual D2-347-2 GV3000/SE AC Drive 30-00 HP, 230V AC Version 6.04 Important User Information Solid-state equipment has operational characteristics

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Embedded EtherNet/IP Option Card for DriveLogix 5730 Controllers

Embedded EtherNet/IP Option Card for DriveLogix 5730 Controllers Installation Instructions Embedded EtherNet/IP Option ard for DriveLogix 5730 ontrollers!!! TTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged before

More information

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control Installation Instructions Second Encoder Option ard for PowerFlex 700S Drives with Phase II ontrol!!! TTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board Installation Instructions PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board!!! ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

EH-RIO IP67 Profibus-DP I/O modules

EH-RIO IP67 Profibus-DP I/O modules Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

ControlLogix Redundancy Update and Module Replacement Guidelines

ControlLogix Redundancy Update and Module Replacement Guidelines Reference Manual Original Instructions ControlLogix Redundancy Update and Module Replacement Guidelines Product Family ControlLogix 5570 Controllers Important User Information Read this document and the

More information

DeviceNet ArmorBlock Network and Auxiliary Powered Module, Series A

DeviceNet ArmorBlock Network and Auxiliary Powered Module, Series A Installation Instructions DeviceNet ArmorBlock Network and Auxiliary Powered Module, Series A Catalog Number 1732D-8X81212HD Topic Page Important User Information 2 Environment and Enclosure 3 Prevent

More information

PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board

PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board Installation Instructions PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives with Bypass 3.0 50HP @ 208V AC 3.0 350HP @ 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum 5

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

PCI 2 Axis Servo Card

PCI 2 Axis Servo Card Installation Instructions PCI 2 Axis Servo Card (Catalog Number 1784-PM02AE) This manual provides the instructions for installing the PCI 2 Axis Servo card (1784-PM02AE) in a PC computer using the NT operating

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

EtherNet/IP Adapter. 20-COMM-E FRN 2.xxx. User Manual. AB Drives

EtherNet/IP Adapter. 20-COMM-E FRN 2.xxx. User Manual. AB Drives AB Drives EtherNet/IP Adapter 20-COMM-E FRN 2.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety

More information

POINT Guard I/O Safety Modules

POINT Guard I/O Safety Modules User Manual POINT Guard I/O Safety Modules Catalog Numbers 1734-IB8S, 1734-OB8S, 1734-IE4S Important User Information Read this document and the documents listed in the additional resources section about

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Bulletin 1608P HC-DySC Dynamic Voltage Sag Corrector

Bulletin 1608P HC-DySC Dynamic Voltage Sag Corrector Installation Instructions Bulletin 1608P HC-DySC Dynamic Voltage Sag Corrector 1608P-200A480V...-HC Models Important User Information Solid-state equipment has operational characteristics differing from

More information

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4

LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4 LiquiFlo AC General Purpose (Volts/Hertz) and Vector Duty Drive Software Start-Up and Reference Manual Version 6.4 Instruction Manual D2-3410-7 The information in this manual is subject to change without

More information

PowerFlex 525 AC Drive

PowerFlex 525 AC Drive PowerFlex 525 AC Drive PowerFlex 525 AC drives feature an innovative, modular design offering fast and easy installation and configuration. These cost-effective compact drives come with embedded EtherNet/IP

More information

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.8 07/2016 A5E00331460A Legal

More information

Allen-Bradley 1397 L11 I/O Expansion Card

Allen-Bradley 1397 L11 I/O Expansion Card Installation Instructions IN Allen-Bradley 1397 L11 Expansion Card Cat. No. 1397-L11 What This Option Provides The Expansion Card is a drive mounted board that provides these additional signals. (5) Digital

More information

The identified danger could cause physical and property damage.

The identified danger could cause physical and property damage. Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor

More information

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000 GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000 Instruction Manual D2-3390-2 The information in this manual is subject to change without notice. Throughout this manual, the

More information

PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers

PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers Installation Instructions PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers Topic Page Introduction, Compatibility 1 Additional Resources

More information

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria DRT-301 A/D Three phase four wire DIN rail energy meter (Seven modules) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

High Speed Remote I/O Module

High Speed Remote I/O Module High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital

More information

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010 Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board Installation Instructions PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement

More information