COUNTER KCV KCX KCM TC-V TC-4 KT-V FC2-81 /FC2-161 /321 FC2-80 /FC2-160 /320

Size: px
Start display at page:

Download "COUNTER KCV KCX KCM TC-V TC-4 KT-V FC2-81 /FC2-161 /321 FC2-80 /FC2-160 /320"

Transcription

1 KCV KCX KCM TC-V TC- KT-V FC-/FC-/ FC-0/FC-0/0

2 / Controller s Lineup KCV INFORMATI Model Number KCV-S KCV-S-C KCV-T KCV-T-C KCX- KCX-D KCX-DM KCX-B Classification Single preset (With prediction output) Single preset (With prediction output) Total counter Total counter Single preset Single preset Single preset Single preset Digit Counting System Increment and Decrement Increment or Decrement Increment Decrement Prescale Functions Display Counting Speed Input/Output Numerical Red LED Red LED Red LED Red LED Green LED Green LED Green LED Selectable (0 Hz, 00 Hz, khz, 0 khz) Selectable (0 Hz, 00 Hz, khz, 0 khz) Selectable (0 Hz, 00 Hz, khz, 0 khz) Selectable (0 Hz, 00 Hz, khz, 0 khz) / digits: 0 Hz/00 Hz / digits: 0 Hz/ khz / digits: 0 Hz/ khz / digits: 0 Hz/00 Hz / digits: 0 Hz/ khz / digits: 0 Hz/ khz / digits: 0 Hz/00 Hz / digits: 0 Hz/ khz / digits: 0 Hz/ khz 0 Hz/0 khz Supply Voltage 00 to 0 V AC to V DC 00 to 0 V AC to V DC 00 V/00 V AC 00 V/00 V AC 00 V/00 V AC 00 V/00 V AC Power Source for Sensors V DC, 0 ma V DC, 0 ma V DC, 0 ma V DC, 0 ma V DC, 0 ma Retentive Function (for powerfail) Possible Possible Possible Possible Available V DC, 0 ma KCV KCX KCM Remarks Preset operation with each digit key, large-size red LED display, double output with prediction output Preset operation with each digit key, large-size red LED display, double output with prediction output Large-size red LED display, position display function Large-size red LED display, position display function Generalpurpose preset counter, green LED numerical display Generalpurpose preset counter, green LED numerical display Generalpurpose preset counter, green LED numerical display Preset counter that enables counting up and down. Comparative output operation is enabled. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

3 / Controller s Lineup KCX KCM KCX-BM KCX-W KCX-WM KCX-BW KCX-BWM KCX-T KCX-BT KCM-0- () KCM-0P- () KCM-- () INFORMATI Single preset Double preset Double preset Double preset Double preset Total counter Total counter Consolidated counter Consolidated counter Consolidated counter Green LED Green LED Green LED Green LED Green LED Green LED Green LED Red LED Red LED Red LED 0 Hz/0 khz / digits: 0 Hz/ khz / digits: 0 Hz/ khz / digits: 0 Hz/ khz / digits: 0 Hz/ khz 0 Hz/0 khz 0 Hz/0 khz digits: 0 Hz/ khz digits: 0 Hz/ khz digits: 0 Hz/0 khz 0 Hz/0 khz 0 Hz/00 Hz 0 Hz/00 Hz 0 Hz/00 Hz 00 V/00 V AC 00 V/00 V AC 00 V/00 V AC 00 V/00 V AC 00 V/00 V AC 00 V/00 V AC 00 V/00 V AC V DC V DC V DC V DC, 0 ma V DC, 0 ma V DC, 0 ma V DC, 0 ma V DC, 0 ma V DC, 0 ma V DC, 0 ma Available Available Available Available Available Available Available Available Preset counter that enables counting up and down. Comparative output operation is enabled. General purpose double preset type General purpose double preset type Double preset counter that enables counting up and down. Comparative output opreration is enabled. Double preset counter that enables counting up and down. Comparative output opreration is enabled. Generalpurpose Position display is enabled. 9 built-in triple preset counters, previous prediction lamp, prediction output, facility stop output 9 built-in triple preset counters, previous prediction lamp, prediction output, facility stop output built-in triple preset counters, any counter reset. Timer function is enabled. KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

4 / Controller INFORMATI KCV Series Features Increment-Decrement Type, Single Preset Increment- Decrement Type Total - Maximum counting speed 0 Hz/0 khz (Can be selected by DIP switch.) 00 Hz/ khz (Can be selected in setup mode.) - Preset counter of DIN x miniature body that consolidates the easy-to-see large two-color LED display and enhanced functions - By setting the prediction output value, double output - prediction output and preset output - can be set. KCV KCX KCM Features Easy-to-see Large Display The DIN x miniature body has a large LED display of a character height of mm ( digits) and 0 mm ( digits). Easy-to-understand Operability Preset values can be set and changed like with a digital switch, using the setting keys for each digit. Unrestricted Digit Setting The counter can be set for any number of digits according to applications. Retentive Memory without Battery Backup An EEPROM is used for memory storage and a battery that does not require maintenance is used. Removable Terminal Block This removable terminal block improves maintenance. After wiring, the terminal block cover enhances safety. Protection Functions for Each Key Key protection can be set for each key to prevent unintended operation. Power Source for High-capacity Sensor The AC type has a built-in V DC, 0mA power source for sensors. Sensors such as encoders and proximity sensors can be connected to the counter. Multi-voltage Power Supply for AC Type The AC type is workable with supplied voltage at to V AC that can be used around the world. Various Counting Functions Prescale functions Input pulse can be converted into any value and displayed. Individual -phase increment / decrement input The counting range is possible from plus to minus. (However, the setting should be in the positive range.) Count-up and count-down The count display can be selected between count-up display and countdown display. Double Output by Prediction Output Double setting with prediction output is possible. Predicted values are used until the preset value is reached. 0 khz High-speed Response Input response frequency is 0 khz, which is the highest in this counter class. In accordance with input counting speed, switching among 0, 00, k, and 0 khz is possible. Protection Fulfilling IP Sheet keys are used for the front panel, which enables users to safely operate the device even with wet or unclean hands. To improve the protective structure, the front cover is also available at option. Conformity to CE and UL CE marking compliant and UL standard (UL0) certified product 90 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

5 / Controller Model Number List Classification Model Number Digit Power Source Preset Total KCV- - - Series - Number of digits : digits : digits Power Source for Sensors V DC, 0mA KCV-S AC Open KCV-S-C DC Open KCV-S AC Open KCV-S-C DC Open KCV-T AC Open KCV-T-C DC Open KCV-T AC Open KCV-T-C DC Open AC: 00 to 0 V AC DC: to V DC KCV Series Specifications Price INFORMATI - Output format S : With output T : Total - Power source type Blank : AC power C : DC power General Specifications Items AC Power Rating Supply Voltage 00 to 0 V AC to V DC Allowable Power Range to V AC 0 to. V DC Power Consumption Approx. VA Approx. W Power Source for Sensors V DC (0 to V) 0 ma (Ripple noise: 0% p-p or lower) DC Power Power Failure Memory Ambient Temperature Storage Temperature Ambient Humidity EEPROM -0 to 0 C -0 to 0 C (No freezing) Number of overwrite cycles: 00,000 cycles or more Storage time: 0 years to % RH (No condensation) Withstand Voltage kv AC min (0 V, between relay contacts) kv AC min (0 V, only between relay contacts) Vibration Resistance Impact Resistance Noise Resistance Protective Structure Endurance Malfunction Endurance Malfunction Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions 90 m/s ms, axial directions 9 m/s ms, axial directions Between power supply terminals. kv (Pulse width μs, start-up ns) IP (Only the front panel part) Weight (g) Approx. 0 Approx. 0 Terminal Block Conforming cable 0. to. mm Conforming crimp terminal Allowable tightening torque R.- 0. Nm Between power supply terminals.0 kv (Pulse width μs, start-up ns) KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

6 / Controller INFORMATI KCV Series Specifications Performance Specifications Items Preset Total Type Increment and decrement preset counter Increment and decrement total counter Setting Single setting with prediction output Digit, digits, digits Display (LED character height) digits: mm (Count)/ mm (Preset) digits: 0 mm (Count)/ mm (Preset) Counting Range digits: -999 to 9,999 digits: -99,999 to 999,999 Setting Range digits: 0 to 9,999 digits: 0 to 999,999 Input Disabled Count Input External Reset Automatic Reset Manual Reset Input Gate Duration During Power Failure Counting Speed: 0/00/ k/0 khz Input resistance: Positive logic kωnegative logic. kω (AC power)/. kω (DC power) Input voltage: "L" 0 to V"H" to 0 V Responsivity: 00 μs or lower Minimum signal width: ms Responsivity: 00 μs or lower Responsivity: 0. s or lower 0 to 00 ms Input Gate Duration During Power Recovery 0 to 00 ms Output Non-contact output: NPN open collector output V 00 ma, withstand voltage: V, residual voltage:. V or lower Contact output: transfer, (c) contact point, 0 V AC A (Resistance load) Output Mode Single shot / holding / coincidence Output Time 0 to 9,990 ms, every 0 ms Prescaling Decimal Point 0.00 to ( digits)/0.00 to ( digits) Any digit can light up. Key Protection Any key setting is enabled. Reset key setting is enabled. Installation Method Dedicated to embedded installation (Terminal block connection) * The prescale column shows the value without using the multiplication. KCV KCX KCM Input/Output Specifications Count Input Disabled Count Input Input Speed Input Resistance Input Voltage Input Response Input Resistance 0 Hz/00 Hz/ khz/0 khz Positive logic: kω Negative logic:. kω (AC power)/. kω (DC power) L: 0 to V H: to 0 V On delay: 0. ms Off delay: 0. ms Positive logic: kω Negative logic:. kω (AC power)/. kω (DC power) External Reset Input Input Voltage Input Response Input Resistance L: 0 to V H: to 0 V On delay: ms or less Off delay: ms or less Positive logic: kω Negative logic:. kω (AC power)/. kω (DC power) Transistor Output Contact Output Input Voltage Withstand Voltage Current Residual Voltage L: 0 to V H: to 0 V V or lower 00 ma or lower V or lower Contact Capacity 0 V AC A (Resistance load) 0 V AC 0. A (cos = 0.) 0 V DC 0. A (L/R = ms) Life 00,000 times or more 00,000 times or more 00,000 times or more 9 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

7 Output Operation Mode Mode Counting Output Holding Continuous Holding One-shot Reset Output Operation Chart Holding Output (Continuous Count) One-shot Output (Reset Count) Coincidence Output (Continuous Count) One-shot* 0 to 9,990 ms Coincidence Continuous Coincidence * Can be set every 0 ms between 0 and 9,990 ms. (Set in the setup mode.) Preset Values Predicted Value 0 Reset Non-contact Output Contact Output Preset Values Predicted Value Reset Non-contact Output Contact Output Predicted Value Preset Values Predicted Value 0 0 Increment mode Increment mode Increment mode Decrement mode Decrement mode One-shot time 00 ms (0 to 9,990 ms is possible in setup mode.) Decrement mode "H" IN-A "L" "H" IN-B "L" / Controller Counting Timing Dual input mode T Increment "H" IN-A "L" "H" IN-B "L" "H" IN-A T/ T/ T/ T/ T KCV Series Output Operation T/ T/ T/ T/ T Decrement T/ T/ T/ T/ T Individual "L" Increment/Decrement Input Mode (Positive Logic Input) T/ T/ Increment T Decrement "H" "H" IN-A IN-B "L" "L" "H" IN-B "L" IN-B in Increment input can be either "H" or "L." T/ T/ T IN-B in Increment input can be either "H" or "L." IN-A in Decrement input can be either "H" or "L." Individual Increment/Decrement Input Mode (Negative Logic Input) Increment Increment Decrement Decrement "H" "H" IN-A IN-A "L" "L" "H" "H" IN-B IN-B "L" "L" Increment T/ T/ T/ T/ () Increment () T/ T/ T/ T/ T T IN-B in Increment input IN-B in Increment input can be either "H" or "L." can be either "H" or "L." T/ Decrement Decrement IN-A in Decrement input can be either "H" or "L." T/ T T T/ T/ IN-A in Decrement input IN-A in Decrement input can be either "H" or "L." can be either "H" or "L." T/ T/ T/ T/ T T INFORMATI KCV KCX KCM Reset Non-contact Output Contact Output <Note> <Note> Count for or. Required counting speed (Herz) = Count for or. Required counting speed (Herz) = T sec T sec : Prediction Set Value For output display for prediction output (non-contact output), the output LED blinks. When the prediction set value is "0," non-contact output becomes the same as the output operation of contact output. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

8 / Controller INFORMATI KCV Series Connection Terminal Connection Diagrams KCV-S/S Power Source for Sensor V DC, 0mA Count Input Disabled Count Input INA INB 0 V INH Non-contact Output OUT Reset Input R KCV-S-C/S-C Count Input Disabled Count Input INA INB 0 V INH Non-contact Output OUT Reset Input R * Non-contact output (OUT terminal) is also used for prediction output. KCV-T/T Power Source for Sensor V DC, 0mA 9 0 COM N.C. N.O. Contact Output 00 to 0 V AC Power Count Input Disabled Count Input INA INB 0 V INH Reset Input R * Non-contact output (OUT terminal) is also used for prediction output. KCV-T-C/T-C 9 0 COM N.C. N.O. + Contact Output to V DC Power Count Input Disabled Count Input INA INB 0 V INH Reset Input R to 0 V AC Power to V DC Power Input/Output Circuit Diagrams AC Power DC Power KCV Power Source for Sensor V DC Internal V During Negative Logic Input V. k 9 N.C. COM V DC + Internal Circuit During Negative Logic Input V. k 9 N.C. COM KCX KCM INA k k 0 N.O. INA k k 0 N.O. V. k V. k INB k INB k Reset k V. k k OUT 0 V Reset k V. k k OUT 0 V k k V. k V. k Disabled Count Input k k Disabled Count Input k k 9 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

9 / Controller Input Connection Examples NPN Open Collector Output Proximity Sensor - Input logic: Negative logic (No-voltage input) (neg) - Input mode: Individual increment and decrement input (DIP switch is.) Recommended proximity sensor: APS--N/E -wire DC System Reset Proximity Sensor - Input logic: Negative logic (No-voltage input) (neg) Black Black - Input mode: Individual increment Disabled Count and Input Disabled Count Input decrement input (DIP switch is.) Recommended proximity Blue sensor: Blue APS--Z 0 V 0 V * In the case of the DC power source type, the supply voltage should be not less than 0 V. Switch Relay 0 V 0 V - Input logic: Negative logic (No-voltage input) (neg) - Input mode: Individual increment and decrement input (DIP switch is.) - Counting speed: 0 Hz (DIP switch is.) KCV Series Connection Voltage Output or PNP Open Collector Output Proximity Sensor - Input logic: Positive logic (Voltage input) (pos) - Input mode: Individual increment and decrement input (DIP switch is.) Recommended proximity sensor: APS--E Brown Power Source for Sensor ( V DC)* Brown Power Source for Sensor For Increment Black ( V DC)* IN A For Increment Black NPN For NPN Decrement PNP PNP IN A Black IN B For Decrement Black IN B Black Brown Brown Power Reset Source for Sensor Power Source for Sensor Brown Brown Power Source for Sensor Power Source for Sensor ( V DC)* ( V DC)* ( V DC)* ( V DC)* Black Reset For Increment For Increment Black For Increment For Increment Black Black Disabled Count Input Black Black IN A IN A IN A IN A Black Blue Disabled Count Input For Decrement For Decrement 0 V For Decrement For Decrement Black Black Black Black IN B IN B IN B Blue IN B 0 V Rotary Reset Encoder - Input logic: Positive logic and negative logic are set in accordance with the Black Black output of Disabled the encoder. Count Input Disabled Count Input - Blue Input mode: -phase Blueinput (DIP switch is.) 0 V 0 V Recommended rotary encoder: TRD-SB TRD-J-RZ/S TRD-N-RZ/S DC DC For Increment Brown Red IN A Red (Brown) Red Power Source for Sensor Blue For Decrement (Brown) Power Source (Brown) for Sensor ( Power V DC)* Source for Sensor Green IN B ( V DC)* (Black) ( V DC)* For Increment For Increment Brown Brown Green Green IN A IN A IN A (Black) (Black) Blue Blue Reset IN A IN A For Decrement For Decrement IN B IN B IN B White Disabled Count Input IN B IN B White (White) Reset Reset (White) (White) 0 V Black 0 V 0 V 0 V Black Black (Blue) Disabled Count Input Disabled Count Input (Blue) (Blue) For Increment For Decrement Black Black Reset Power Source for Sensor Power Source for Sensor ( V DC) ( V DC) For Increment IN A IN A For Decrement IN B IN B For Increment For Decrement Black Black Reset - Input logic: Positive logic (Voltage input) (pos) - Input mode: Individual increment and decrement input (DIP switch is.) - Counting speed: 0 Hz (DIP switch is.) Power Source for Sensor Power Source for Sensor ( V DC)* ( V DC)* For Increment IN A IN A For Decrement IN B IN B INFORMATI KCV KCX KCM Reset Reset Reset Reset Disabled Count Input Disabled Count Input Disabled Count Input Disabled Count Input 0 V Because there is 0 large V input Because current, there is large input current, this connection is recommended. this connection is recommended. 0 V 0 V * There is no power source for sensors in the case of the DC power source type. DC DC Use a separate external power source. Output Connection Examples NPN Open Collector Output OUT 0V Load OUT + Load + Power Source 0Vfor Load V DC Power Source for Load V DC COM N.C. 9 N.O. 0 Contact Output COM Load N.C. 9 Load N.O. 0 Power Source for Load Load Load Power Source for Load The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

10 / Controller KCV Series Each Part Name and Function INFORMATI Panel Explanation Output display (Red) - Operation mode Lights up when the output is. Blinks when the prediction output is. Protection display (Red) - Operation mode Blinks when the key is protected. (Only when the key is ) - Setup mode Displays the set contents of key protection. RST key - Operation mode Resets the discrete value. (0 in increment mode, preset value in decrement mode) - Setup mode Select the setting item. * Compared with the pre-set counter panel above, the total counter differs as to the following points. Output display : None Protection display : None except the display corresponding to the RST key. Preset value display : No display in the operation mode. Digit key : Ineffective in the operation mode. Discrete value display (Red) - Operation mode Displays the discrete value. - Setup mode Displays the set contents. Preset value display (Green) - Operation mode Displays the preset value. - Setup mode Displays the setting item. Digit key - Operation mode Changes the preset value. (The preset value is updated approx. one second after the change is made as long as there is no input from any of the keys.) - Setup mode Selects the set contents. Key Operation. Changes the preset value Every time a digit key is pressed, is added to the preset value of the corresponding digit. Approx. second after a digit key is released, the set value is entered. Example: When the counter is Press the key and the Press the key and the Press the key and the KCV KCX KCM. Resets the discrete value If the reset key is pressed (response time is 0. s), the discrete value is reset. If the [RST] key is pressed, the discrete value becomes "0" in the increment mode and the preset value in the decrement mode..key protection When DIP switch is, the reset key and the digit key are locked. When the prohibited key is pressed, the LED corresponding to the key blinks. For key protection, select the key you want to lock in the setup mode and set DIP switch in the position. Since all key protections in the setup mode are locked before shipment, if you simply set DIP switch in the position, all keys lock. RST 9 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

11 / Controller DIP Switch Setting - Use the DIP switch at the top of the counter for setting. - Before operating the DIP switches, be sure that the power is turned off. The switches do not respond to setting changes while the power is on. - When a DIP switch is changed, be sure to press the [RST] key in the operation mode to reset the count value. Dip Switch * The DIP switches are all set in the position before shipment. Selects the operation mode. Not in use Selects the key protection. Selects the output mode. (Unused by the total counter) Selects the counting memory. Selects the counting mode. (The addition mode is fixed in the total counter.) Selects the input mode. Selects the counting speed. KCV Series Each Part Name and Function Counting Speed Select the counting speed with DIP switch. Select a counting speed that is not Counting included amongst speedthe choices (00/ khz) in the setup mode. Counting speed Counting Speed SW Counting speed Counting 0 Hz Speed SW Counting speed Counting 0 Hz Speed SW 0k Hz Counting 0k 0 Hz Hz Speed SW Counting 0k 0 Hz Speed SW Input Mode Select Input the mode input mode with DIP switch. 0 Hz 0k Hz 0k Hz Input mode Input Mode SW Input mode Input Mode SW Add-Subtract individual input Input mode Add-Subtract Input individual Modeinput SW -phase input Add-Subtract -phase Input individual Mode input input SW Add-Subtract -phase Input individual Mode input input SW Counting Mode Select Counting the counting mode mode with DIP switch. Add-Subtract individual input -phase input -phase input Counting mode Counting mode Counting Mode SW Counting mode Decrement Counting Mode mode SW Decrement Increment Counting Mode mode SW Decrement Increment Counting Mode mode SW Decrement mode Counting Memory Increment mode Counting memory Increment mode Select the counting memory with DIP switch. Counting memory Counting memory Counting memory Counting Power failure source Memory memory reset SW Counting Power failure source Memory memory reset SW Power failure memory Power source reset Output Output Mode mode Power source reset Select Output the output mode mode with DIP switch. Select the coincidence output in the setup mode. Output mode Output Mode SW Output mode Output Hold output Mode SW One-shot Output Hold output Mode output SW Output Mode One-shot Hold output SW Hold output One-shot output One-shot output Key Protection Key protection Select whether "not to use key protection" or "to use key protection" for the Key protection keys set in the setup mode with DIP switch. The keys for key protection can be Key set in protection the setup mode. Key Protection "Not Key SW to protection use key protection" is set before shipment. The Key setup Protection mode SW settingis The Key setup Protection enabled. mode SW settingis Key Protection enabled. SW The setup Do not mode settingis The setup Do enabled. not mode settingis enabled. Do not Operation mode Do not Operation mode Operation mode Mode Select Operation the operation mode mode with DIP switch. Operation Mode Operation Setup mode Mode SW SW Operation Setup mode mode Mode SW Operation Mode Operation Setup mode SW Setup mode Operation mode Operation mode * Dip switch is not used. * Dip switch is not used. *Dip switch is not used. * Dip switch is not used. * Dip switch is not used. Counting Memory Counting Power failure Memory memory SW SW INFORMATI KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

12 / Controller INFORMATI KCV Series Each Part Name and Function Setup Mode Make settings that cannot be selected with the DIP switches, in the setup mode. Setup Mode Setting Items () Counting speed 00/ khz, DIP switch () Input logic Positive logic, Negative logic () Output mode Coincidence output, DIP switch () Output time Set the one-shot output time from 0 to 9,990 ms (in units of 0 ms). () Prescaling digits: 0.00 to digits: 0.00 to () Magnification of prescale Set the magnification of the value set in the prescale. time, 0 times, 00 times,,000 times () Digit Set the number of digits to display on the counter. digits: to digits digits: to digits () Decimal point Set the decimal marker to any digit. (9) Prediction output Set the offset value for the preset value. digits: 0 to 9,999 digits: 0 to 999,999 (0) Reset key protection Set the lock for the reset key. () Digit key protection Set the lock for the digit keys. * Items (), (), (), (9), (0), and () are skipped in the total counter. To the next menu by pressing the reset key RST RST RST RST RST Counting speed setting (cps) 000 khz Hz dip Dip switch Input logic setting (si g) pos Positive logic neg Negative logic Output mode setting (c-op) eq Coincidence output dips DIP switch Output time setting (outt) Digit key is disabled as the setting is performed in units of 0 ms. Discrete value display part Blank s Digit key Variable from 0 to 9990 ms Prescale setting (scl) Initial value: Initial value: Initial value: Initial value: 00ms Initial value:.000 Discrete value display part Digit key digits: 0.00 to digits: 0.00 to Switching Between the Setup Mode and the Operation Mode Operation Mode Setup Mode When DIP switch is in the position and the power is turned on, the setup mode starts. When the DIP switch is in the position and the power is turned on, the operation mode starts. RST RST Prescale setting (scl) times times times time Digit selection setting (dgt) Initial value:.000 Initial value: Maximum digit The number of digits corresponding to the digit keys is displayed. Discrete value display part Digit key KCV KCX KCM Operation of the setup mode Initialize the setup mode using the menu as shown in the table on the right. (Use the digit keys for all settings.) - The digits that were selected in the digit selection setting will be available later when setting the decimal point, prediction output, and digit key protection, and only the selected digits can be set. - If the digit selection setting is changed, the decimal point setting is automatically changed to "no decimal point," the prediction output setting to "0," and the preset value to "." - If the default setting is changed in the setup mode, be sure to press the [RST] key in the operation mode to reset the count value. - The set contents become effective when moving to the next menu via the [RST] key. - If the [RST] key is pressed and pressed for seconds or more in the operation mode, the "prediction output setting" screen in the setup mode appears. When the [RST] key is pressed after making a setting, the operation mode screen appears. * Items and are skipped in the total counter. Digit key K/P display part : Not use : Lit when disabled : Use : Enabled when out RST RST RST To the first menu by pressing the reset key RST Decimal point setting (d. p) The decimal point appears after the digit number corresponding to the digit key number. Digit key is used for the setting for no decimal point. Discrete value display part Digit key Prediction output setting (set ) Discrete value display part Digit key Reset key protection setting (rpro) Initial value: Locked Select whether to lock the reset key or not. Digit key: K/P display part : (Lock) : (Unlock) Digit key protection setting (ppro) Initial value: Locked Select the whether to lock each digit key or not. ( digits: / digits: ) Digit key: K/P display part : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) a Initial value: No decimal point Initial value: 0 9 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

13 / Controller Operation Mode Changes the Preset Value Change the preset value from 0 to 0. The preset value becomes effective approx. second after the change is made. Before Changing OUT K/P RST OUT K/P RST OUT K/P RST Change Complete OUT K/P RST. Change the set contents To the next menu by pressing the reset key KCV Series Example of SettingKCV-S Counting speed Setting screen Change to the initial value. RST Input logic Setting screen RST Change to the initial value. INFORMATI Press the digit key twice. Press the digit key Once. Positioning by the Encoder Input Position the conveyer in units of 0. mm. To accurately stop the conveyor, output the prediction output 0 mm in front of the preset value. OUT K/P KCV-S RST Pulley Encoder Prediction Output (Deceleration) present Output (Suspended) RST RST RST Output Setting mode screen Change to the initial value. Output time Setting screen Change to the initial value. Prescale setting Setting screen Set the prescale to "0.0." Press the key 9 times, the key times, and the key times to set the prescale to "0.0." Prescale setting Setting screen Control Box Motor Set the magnification to "0." - Pulley diameter : - Encoder pulse count :,000 P/R Counting Speed Input Logic Output Mode Output Time Setting Item.Prescale calculation 0 khz* Negative logic* One-shot* 00 ms* Prescaling 0.0 Magnification 0 Digit * Decimal Point Prediction Output 0.0 * Items with an * mark are set before shipment. Prescaling = = Pulley Diameter (mm) Encoder Pulse Count. 000 = 0.0 mm/pulse Settings Between st digit and nd digit = (to display in units of 0. mm). Switching to the setup mode Set DIP switch in the position and turn the power on. (DIP switches to are in the position.) RST RST RST Press the reset key to end setup. RST Press the key once to set the magnification to 0. Digit Setting screen Change to the initial value. Decimal point Setting screen Display the decimal point between the first and second digits. Press the key to display the decimal point between the first and second digits. Prediction output Setting screen Set the prediction output to "0." Press the key twice to set the prediction output to "0.0." This setting is complete.. Switching to the operation mode When setup is completed in the setup mode, turn the power off and set DIP switch in the position (to the operation mode). (The set contents in the setup mode are written when the power is turned off.). Start the operation mode When a setting is changed in the setup mode, be sure to press the [RST] key to reset the count value after the power is turned on. KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 99

14 / Controller KCV Series Error Code Display/Option Common Errors Error Code Error Name Error details Corrective Action Memory data error The preset values and the contents of setup mode are changed. Press the [RST] key and delete the error indication. The discrete value becomes "0", the set value becomes "000", and the contents of the setup mode revert back to the preshipment defaults. INFORMATI Decimal Point Blinking Decimal Point Blinking Minus Display overflow error underflow error Overflow Error All digits in the display turn to 0. Count values have exceeded the display range. Count values are below the display range. The error indication is cancelled if the [RST] key is pressed to reset the discrete value or if the discrete value returns within the counting range. Inside the counter, the discrete value is correctly counted in the range of -,,. to,, Decimal point blinking Decimal Point Blinking Underflow Error Minus Display Decimal Point Blinking Decimal Point Blinking Option Rubber Gasket Option Model Number Contents Price KC-P If installed between the installation panel and KCV, it prevents the intrusion of water into the control panel. Open Front Cover KC-C If installed to the front panel, it protects the counter from exposure to dirt, etc. Material: Soft silicon rubber Key operation is enabled with the front cover installed. Open KCV KCX KCM 00 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

15 / Controller Precautions in Use () The power source 0 V terminal and the input common 0 V terminal of the DC type are internally short-circuited. () Rather than gradually increasing the supply voltage, apply the rated voltage at once using a switch or relay. () When using the -wire DC system proximity sensor, set the input logic to negative logic. () When changing the preset value while counting, the changed preset value becomes effective approx. second after the key input. In the decrement mode, the changed preset value becomes effective when the counting is reset. (Effective preset values are memorized during power failures.) () Enter the set contents of the DIP switches and the setup mode in the data sheet attached to the main body and keep it for maintenance. () Do not use the counter in the following environments. - Any place where the ambient temperature exceeds 0 C or falls to -0 C or lower. - Any place where the ambient humidity exceeds % or condensation occurs due to rapid temperature change. - Any place that is exposed to dust, iron powder, and corrosive gas. - Any place that is exposed to sunlight. - Any place where there are large vibrations or shocks. () When performing a dielectric voltage test or insulation resistance test, separate the main body from the control circuit. Cautions in Wiring - Wire cables separately from power lines. - When using the counter in a place where a lot of noise is generated, separate the main body of the KCV and the wiring from the noise sources as far as possible. - Do not use an unused terminal as a relay terminal. - It is recommended to use a crimp terminal for connections. - When wiring the cable to the terminals and, if the crimp terminal has a fork shape, do not attach it diagonally. For diagonal attachment, use a round crimp terminal. In the Case of a Forked Crimp Terminal KCV Series Precautions If the crimp terminal is diagonally attached, the contact with the terminal becomes insufficient. Therefore, attach the crimp terminal horizontally from the side as shown in the figure above. In the Case of a Round Crimp Terminal INFORMATI Insert the main body into the attachment bore of the panel. How to Mount and Remove the Main Body How to Mount the Main Body Insert the main body into the attachment bore of the panel. As the screw for anchoring the terminal block, only use the anchoring screw used in shipping. How to Mount the Terminal Block and the Terminal Block Cover Make sure that the allowable tightening torque is 0. Nm. As the screw for anchoring the terminal block, only use the anchoring As Mount the screw the terminal for used anchoring block cover shipping. the terminal after the block, wiring is completed. Make sure that the only allowable use the anchoring tightening screw torque used is 0. in Nm. shipping. Mount the terminal Make block sure cover that the after allowable the wiring tightening is completed. torque is 0. Nm. Mount the terminal block cover after the wiring is completed. Attach the mounting frame from the backside. Attach the mounting frame from the backside. Body Body Body Terminal Block KCV KCX KCM Mounting Frame: The frame can be mounted both in the longitudinal and transverse directions. Mounting Frame: The frame can be mounted both in the longitudinal and transverse directions. Fixing Screw Terminal Block Terminal Block Terminal Block Cover Fixing Screw Fixing Screw Terminal Block Cover Terminal Block Cover How to remove the main body Pinch the levers to spread them to mm outwards. Pull out the frame while the levers are spread. Pinch the levers to spread them to mm outwards. Pull out the frame while the levers are spread. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 0

16 / Controller INFORMATI KCV Series Dimensions Dimensions Main Body of the KCV Mounting Frame (Unit: mm) 0 (DC Power) 00 (AC Power). to : Mounting Panel Thickness 0 0 Terminal Block Detail Drawing.=0.. Terminal Screw.. M 9. Panel-cut Dimensions for Embedded Installation. When the mounting handle direction is in the transverse direction Mounting Frame 0 or more. When the mounting handle direction is in the longitudinal direction * When arranging the counter after attaching the front cover (KC-C, KC-P), make the alignment dimension mm or more (Tight Mounting is Possible). Square Hole or more or more Conforming cable size : 0. to. mm Conforming crimp terminal : R.- Allowable tightening torque : 0. Nm KCV KCX KCM Front Cover (Option) KC-C. 0. Front Cover Outside Dimensions for Mounting Space Between the Main Body and the Mounting Panel Mounting Panel. 0 (9.). Main Body Front Cover 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

17 / Controller KCX Series List of Model Numbers Preset Classification Model Number Digit Single preset Increment type with input/output display Increment type with numerical display Retentive Feature for Power Failure Counting Speed Power Supply for Sensors Supply Voltage KCX- For both 0 Hz Open KCX- and 00 Hz Open KCX- For both 0 Hz Open KCX- and khz Open KCX-D Open KCX-D For both 0 Hz and 00 Hz Open KCX-DM Open KCX-D V DC, 0 ma Open KCX-DM For both 0 Hz Open KCX-D and khz Open KCX-DM Open KCX-D KCX-DM For both 0 Hz Open KCX-D and khz Open KCX-DM Open Price Open INFORMATI Double preset (With numerical display) Add-subtract type with numerical display Increment type Add-subtract type KCX-B Open For both 0 Hz V DC, 90 to V AC and 0 khz 0 ma KCX-BM 0 to V AC Open 0/0 Hz KCX-W Open KCX-W For both 0 Hz and khz Open KCX-WM V DC, Open KCX-W 0 ma Open KCX-W For both 0 Hz and khz Open KCX-WM Open KCX-BW For both 0 Hz V DC, Open KCX-BWM and 0 khz 0mA Open KCX-T For both 0 Hz and khz Open Total Increment type KCX-T KCX-T For both 0 Hz and khz For both 0 Hz and 0 khz V DC, 0 ma Open Open Add-subtract type KCX-BT For both 0 Hz and 0 khz V DC, 0 ma Open KCV (Accessories) Mounting brackets, dust cover KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 0

18 / Controller INFORMATI KCX-,D/DM Features Green Increment Type, Single Preset - Maximum counting speed For and digits: for both 0 Hz and 00 Hz For and digits: for both 0 Hz and khz For and digits: for both 0 Hz and khz - The to -digit preset electronic counter uses an easy-to-see, bright green color for the numerical display and the input/output display. The electronic counter features various user-friendly functions including thorough dust prevention measures and power failure measures. Features Easy-to-see Green Display An easy-to-see green display is used for the numerical display and the input/ output display (The numerical display is a green LED with a character height of mm.) With input/output display With numerical display For Both A-type (Specific Time Output) and B-type (Self-holding Output) The A-type operation and the B-type operation can be switched by changing the connection of the terminal. KCV KCX KCM Equipped with a Dust Cover as a Standard Feature All models are equipped with a dust cover as a standard feature, and the setter can be operated from outside the dust cover. Dust Cover Digital Switch Improved Space Factor All models for digit to digits have a small design with the front outer shape being DIN size ( x mm) and an overall depth of 0. mm. Retentive Memory without Battery Backup An EEPROM is used for memory storage and a battery that does not require maintenance is used. Built-in Power Source for Sensors All models for digit to digits have a built-in V DC, 0 ma power source for sensors and, therefore, can be directly connected to sensors such as proximity sensors, photoelectronic sensors, and rotary encoders. Wide Variable Range for Output Time In the case of specific time output operation (A-type operation), the output time can be varied from 0 to,000 ms using the volume on the front part of the counter. Moreover, by installing a capacitor on the terminal, the output time can be increased to up to 0 s. Six Kinds of Operation Modes The best operation mode can be selected. A Wide Range of Supply Voltage The supply voltage covers 90 to V AC and 0 to V AC. Counting Input can be Prohibited. By applying input to the counting input inhibit terminal, counting input can be interrupted to stop counting. For Both Embedded and Surface-Mount Installation In the case of embedded installation, the counter can be attached to the panel simply by tightening the dedicated mounting bracket from the back side. In the case of surface-mount installation, the counter can be mounted to and removed from the F terminal (terminal block) by one-touch operation. Dedicated Mounting Brackets Stand F (Terminal Block) Body B Stand (Terminal Block) or Connector 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

19 / Controller Specifications Model Number With Input/ Output Display With Numerical Display Standard KCX- KCX- KCX- KCX- Standard KCX-D KCX-D KCX-D KCX-D KCX-D KCX-D Power Failure Memory Type KCX-DM KCX-DM KCX-DM KCX-DM KCX-DM Digit digit digits digits digits digits digits Operation Format Count Input External Reset For both A-type (Specific time output type, automatic reset) and B-type (Output holding type) Contact input Non-contact input Contact input Non-contact input Contact input Non-contact input Maximum counting speed 0 Hz 00 Hz 0 Hz khz 0 Hz khz Minimum pulse width 0 ms. ms 0 ms 0. ms 0 ms 0. ms Input resistance kω kω kω kω kω kω Input voltage Response time Input resistance Input voltage "L" 0 to V/"H" to 0 V Delay time: 0 ms Delay time: ms kω "L" 0 to V/"H" to 0 V Delay time: 0 ms Delay time: ms KCX-,D/DM Specifications Delay time: ms Delay time: ms Automatic Reset Reset time ms or less ms or less 0. ms or less INFORMATI Power Source Reset* Voltage Output* Contact Output Input/Output Response Time* Power Failure Memory Function Power supply shutdown time Reset time Minimum of 0. s is required. 0. s or less Output resistance. kω (No-load voltage V) Output current Withstand voltage Output time Contact capacity Number of circuits Output time Electrical life Mechanical life Source:. masink:.0 ma V A-type: (Variable), B-type: Self-holding 0 V AC A Transfer circuit (c) A-type: (Variable), B-type: Self-holding million times or more (0 V AC resistance load) million times or more 0 Hz 00 Hz 0 Hz khz 0 Hz khz Voltage Output Approx. 0 ms Approx. ms Approx. 0 ms Approx. 0. ms Approx. 0 ms Approx. 0. ms Contact output Approx. 0 ms Approx. ms Approx. 0 ms Approx. 0 ms Approx. 0 ms Approx. 0 ms Storage time Input gate response time when power failure occurs* * EEPROMNumber of overwrite cycles: 00,000 cycles or more 0 years Typ, 0 ms KCV KCX Input gate response time when the power returns* Typ, 0 ms KCM Power Source for Sensors Withstand Voltage Insulation Resistance Vibration Resistance Supply Voltage Power Consumption Use Ambient Temperature (When Operated) Storage Temperature Use / Storage Ambient Humidity Noise Resistance* Weight V V DC0 maripple % (rms) or lower kv AC min (Between AC power supply terminal, E terminal, and relay contact terminal) 00 V DC0 MΩ or higher Compliant with JIS C 09. Endurance vibration: Displacement amplitude 0. mm, 0 to Hz, axial directions Malfunction vibration: Displacement amplitude 0. mm, 0 to Hz, axial directions 90 to V AC/0 to V0/0 Hz With numerical display: Approx. VAWith input/output display: Approx. VA Power-on: 0 to +0 C Memory storage: -0 to +0 C -0 to + C to % RH (No condensation) μs width, square-wave pulse, kv 0. kg The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 0

20 / Controller KCX-,D/DM Specifications INFORMATI Precautions (See the previous page.) * The power source reset is applied to models except the power failure memory types (KCX- to, KCX-D to D). The "reset time" of the power source reset refers to the time when counting is disabled when the power is turned on. * Voltage output (Non-contact output) When connected to a V systemp load * During a power failure, the functions of each input circuit are stopped. When the power returns, however, each input circuit resumes normal operation by the function of the detection circuit. The "input gate response time when the power returns" refers to the time until each input circuit resumes normal operation and can start receiving the counting input and the reset input after the power is returned. + V Source. kω V or higher * Other than these tests, we confirm the functions by our original test methods including electrostatic discharge tests, inductive load switching tests, and electromagnetic switch oscillation tests in order to ensure safe operation. When connected to a V systemn load + V + to + V kω Sink 0. V or lower When connected to a V system + V + V Sink Vc Vc V when the sink current is 0 ma KCV * The time from the generation of the final pulse of the input signal that reaches the set value in the counting input terminal to the output of the counter. KCX KCM Contact Input Non-contact Input A B KCX C D Voltage Output (Non-contact Output) Contact Output A/B C D t t: Non-contact Output response t t: Contact Output response * The power failure detecting circuit starts operating simultaneously with a power failure, and stops the function of each input circuit (counting and reset input) after a certain period of time, and prevents the counting or reset operation even if an input signal is added. The "input gate response time when power failure occurs" refers to the time until the functions of each input circuit stop. Each input circuit performs normal operation during this time. 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

21 / Controller Operation A-type Operation (Specific Time Output Operation) - When the number of input pulse signals reaches the preset value (countup), the output is produced. - The output time is approx. 0 to,000 ms (volume variable). - If the counter counts up, the counting circuit and the counting display (for the models equipped with a numerical display) are automatically reset, and the operation can be repeated. - Output is also reset by external reset during output time. Retentive memory type When resetting the counting: Add the external reset signal. Power Source KCX-,D/DM Operation B-type Operation (Self-holding Output Operation) - If the number of input pulse signals reaches the preset value (count-up), the output is produced and held. - In the case of the models equipped with a numerical display, if terminal (E), terminal (CH) and terminal (CH) are connected, the counting display is not reset even if the counter counts up, and if the input signal is added, it is counted for the count-up display. However, when terminal (E) and terminal (CH) are connected, if the counter counts up, the counting display is reset to 0. (See the "A-type /B-type operation switching connection method".) Retentive memory type When resetting the output signal and counting: Add the external reset signal. Power Source INFORMATI Count Input Set Value Count Input Discrete Value (Indicated Value) Output External Reset Input Approx. 0 to 000 ms Set Value Discrete Value (Indicated Value) Output External Reset Input Normal type When resetting the counting: add the external reset signal. Or shut down the power source temporarily (0. s or longer). Normal type When resetting the output signal and counting: Add the external reset signal. Or shut down the power source temporarily (0. s or longer). Power Source Count Input Set Value t0. s Power Source Count Input t0. s Discrete Value (Indicated Value) Output External Reset Input Approx. 0 to 000 ms t0. s Set Value Discrete Value (Indicated Value) Output External Reset Input KCV A-Type/B-Type Operation Switching Connection Method When terminal (E) and terminal (CH) are connected, the counter performs the B-type operation, and if they are not connected, the counter performs the A-type operation. In the case of B-type operation (terminals and are connected), if the counter counts up, models equipped with a numerical display reset the counting display to 0. To prevent the counting display from being reset, connect terminals, and. In this way, if the counter counts up, the counting display does not become 0, and if an input is added, it is counted for the count-up display. KCX KCM + V IN (0 cps) IN (High Speed) E CH CH R () Type B Operation The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 0

22 / Controller KCX-,D/DM Connection INFORMATI Terminal Assignment With I/O Indicators Terminal Number Symbol Description + V Power source for sensor IN (0 Hz) Counting input for low speed IN Counting input for high speed* E Ground* (Capacitor ) CH Not connected Switching specific time output/ Holding output (Capacitor ) R External reset input OUT Non-contact output 9 COM. 0 N.O. N.C. 0 to V AC 90 to V AC 0 V AC Relay contact output AC power input Models with a Numerical Display Terminal Number Symbol Description + V Power source for sensor IN (0 Hz) Counting input for low speed IN Counting input for high speed* E Ground* (Capacitor ) Terminal Connections Connection of Counting Input. In the case of contact input signals. In the case of no-contact input signals The counting input can be selected from low-speed input and high-speed input. V. kω or lower Counting Signal V. kω or lower Reset Signal Count Input (: Count) Reset Input (: Reset) Count Input (Low Speed) (High Speed) Reset Input + V IN (0 Hz) R + V IN (0 Hz) () IN (High Speed) E R () CH Switching specific time output/ Holding output (Capacitor ) KCV KCX KCM CH Switching automatic reset / Non-automatic reset R External reset input OUT Non-contact output 9 COM. 0 N.O. N.C. 0 to V AC 90 to V AC 0 V AC Relay contact output AC power input *See Specifications. *Capacitor connection terminal for output time extension.. Connection to the open collector output The counting becomes the reverse action. (Counting when the open collector output changes from to ) PLC. kω or lower. kω or lower + V IN (0 Hz) IN (High Speed) E () R 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

23 / Controller KCX-,D/DM Connection Contact input () When used as shown in the figure below, the voltage and current that flow through the contact point are around ma. Therefore, the use of the contact point for minute electric current improves reliability. Since the contact point of the electromagnetic switch is designed for large current and high voltage, it is not suitable for use for contact input of the counter. () The input response of the counting input terminal (0 Hz) has the following characteristics. Input Voltage T + V () ma IN (0 Hz) A Input Circuit T0 B Connection of the Output. Contact output Electric current is applied to load A and is not applied to load B when counting is completed. (). Non-contact output Source load COM 9 N.O. 0 N.C. Load A Load B Power Source for Load INFORMATI A B ton toff Input Voltage Delay Time (ton) Delay Time (toff) V ms ms V ms ms 0 V ms ms E () OUT 9 0 (+). ma or lower Non-contact Output Voltage L: 0. V or lower H: V or higher. kω or higher Load Since the values above are standard values, T and T0 should have values more than times the values above for actual input signals. Example) Contact input using the power source for sensor ( V DC) T: ms or more, T0: ms or more are required. Sink load In this operation, the current flows in when the output is in the "L" state. This operation is reversed from the normal open collector output, and the output becomes "H" when the counter counts up. ( ) OUT (+) E () ma or lower Non-contact Output Voltage L: V or lower KCV KCX KCM V or lower RL E ( ) The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 09

24 / Controller INFORMATI KCX-,D/DM Connection Example of Connection When Directly Connected to the Sensors A consumption current of + V should be 0 ma or less in total. (For Counting) Proximity Sensor, Photoelectric Sensor, Rotary Encoder, etc. (For Reset) Proximity Sensor, Black (Blue) Photoelectric Sensor, Rotary Encoder, etc. When Operating the s in Parallel. In the case of contact input signals Count Input Red (Brown) Red (Brown) (Low speed) High speed White (Black) Black (Blue) White (Black) + V IN (0 Hz) IN (High Speed) E () R + V IN (0 Hz) E () Simple Input Inhibit Method Using an Unused Input Terminal If the contact point is closed and the input is forcibly applied to terminal, the sensor is prohibited from counting. However, when the sensor output (terminal ) is in the "L" state, if the contact point of input inhibit is closed, the count increases by pulse. Sensor Input Inhibit + V IN (0 Hz) IN (High Speed) How to Prohibit Counting when Output is Produced When using the sensor at high speed, wire the cables as shown by the dotted lines. (Diode: Equivalent to Hitachi S0) E R () + V IN (0 Hz) () E + V OUT IN (0Hz) IN (High Speed) E () 9 0. In the case of no-contact input signals Sensor V R IN (High Speed) () E R Counting Signal KCV KCX KCM IN (High Speed) () E R (kω) N N: Numbers of counter that can be connected in parallel. 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

25 / Controller KCX-,D/DM Connection List of Operation Modes In the case of models with a numerical display, six operation modes are enabled as shown below. Holding Output Output Switching Specific Time Output Discrete Value When Counting Up Reset No Reset Prohibition of Counting Input During Output Timing Chart Terminal Connections INFORMATI A-type Operation Input Counting Output Specific Time B-type Operation Count Up Input Counting -- Output External Reset Count Up Input Counting - Output External Reset Count Up Input Counting Output Specific Time -* or - KCV Input Counting Output External Reset Count Up Set Value is Maintained. -* or - -- KCX KCM Input Counting Output -* or - External Reset - * If the voltage terminal (terminal ) is connected to the low speed input terminal (terminal ), until the input is prohibited after counting up, the counter has the same responsivity as the low speed input terminal. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

26 / Controller INFORMATI KCX-W/WM Features Green Increment Type, Double Preset - Maximum counting speed For and digits: for both 0 Hz and khz For and digits: for both 0 Hz and khz - The to -digit double preset electronic counter uses an easy-to-see, bright green color for the numerical display. The electronic counter consolidates various functions in its compact body, including thorough dust prevention measures and power failure measures. Features Easy-to-see Green Display The numerical display is an easy-to-see green display. (Green LED with mm high characters) Miniature (All Models: DIN Size x mm) All -digit to -digit models are compact with the front outer shape being DIN size ( x mm) and the overall depth 0. mm. For Both Low Speed Input and High Speed Input Low speed input (0 Hz) and high speed input (- to -digit = khz, - to -digit = khz) can be switched from a switch on the back. Output Time Adjustment Volume Counting Speed Changing Switch Operation Mode Changing Switch Equipped with a Dust Cover as a Standard Feature All models are equipped with a dust cover as a standard feature, and the setter can be operated from outside the dust cover. Dust Cover A B KCV KCX KCM Counting Input can be Prohibited. By applying input to the counting input inhibit terminal, counting input can be interrupted to stop counting. Retentive Memory without Battery Backup An EEPROM is used for memory storage and a battery that does not require maintenance is used. A Wide Range of Supply Voltage The KCX-W/WM has a wide range of input voltages from. to 0 V DC and supports input sources from to V systems. Moreover, one model can cover a supply voltage of 90 to V AC and 0 to V AC, thus can be used across a wide range of supply voltages. Switch Switch Operation mode Counting speed A A-type operation khz W WM khz B B-type operation 0 Hz W WM Built-in Power Source for Sensors Since the counter has a V DC, 0mA built-in power source for sensors, it can be connected to proximity sensors, photoelectronic sensors, and rotary encoders. For Both Embedded and Surface-Mount Installation In the case of embedded installation, the counter can be attached to the panel simply by tightening the dedicated mounting bracket from the back side. In the case of surface-mount installation, the counter can be mounted to and removed from the F terminal (terminal block) by one-touch operation. Wide Variable Range for Output Time In the case of the specific time output (A-type operation), the output time can be varied from approx. 0 to,000 ms using the volume on the back of the counter. For the Specific Time Output Type and the Self Holding Output Type Specific time output (A-type operation) and self-holding output (B-type operation) can be switched from a switch on the back. Dedicated Mounting Brackets Stand F (Terminal Block) B Stand (Terminal Block) or Connector KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

27 / Controller Specifications Model Number KCX-W/WM Specifications Standard KCX-W KCX-W KCX-W KCX-W Retentive Memory Type KCX-WM KCX-WM Digit digits digits digits digits Operation Format First set: Only B type (Self-holding output) Second set: A type (Specific time output) Can be switched to B type (Back side switch). INFORMATI Maximum counting speed 0 Hz Changed by switch khz 0 Hz Changed by switch khz Count Input Minimum pulse width Input resistance Input voltage 0 Hz: 0 ms khz: 0. ms kω "L" 0 to V, "H". to 0 V 0 Hz: 0 ms khz: 0. ms Disabled Count Input Response time Input resistance Input voltage On delay: 0. ms or less Off delay: 0. ms or less kω "L" 0 to V, "H". to 0 V On delay: 0. ms or less Off delay: 0. ms or less External Reset Response time Input resistance Input voltage On delay: 0 ms or less Off delay: ms or less kω "L" 0 to V, "H". to 0 V On delay: ms or less Off delay: 0. ms or less Automatic Reset Reset time 0. ms or less 0. ms or less Power Source Reset (KCX- to W) Voltage Output Contact Output Input/Output Response Time Power Failure Memory Function KCX-WM KCX-WM Power Source for Sensor Supply Voltage Use Ambient Temperature Storage Temperature Use / Storage Ambient Humidity Weight Withstand Voltage Insulation Resistance Vibration Resistance Power supply shutdown time Reset time 00 ms or more 00 ms or less Output resistance. kω (No-load voltage V) Output current Withstand voltage Output time Contact capacity Number of circuits Output time Mechanical life Electrical life Voltage Output Contact output Storage time Input gate response time when power failure occurs Input gate response time when the power returns Source:. masink: ma V 0 ms to s 0 V ACA make (c) 0 ms to s 0 million times or more (Resistance load) million times or more (Resistance load) 0 Hz: 0 ms khz: 0. ms 0 Hz: 0 ms khz: 0 ms EEPROMNumber of overwrite cycles: 00,000 cycles or more 0 years 00 ms or less 00 ms or less DC V V0 maripple % (rms) or lower 90 to V AC/0 to V AC0/0 HzApprox.. VA Power-on: 0 to +0 C Memory storage: -0 to +0 C -0 to + C to % RH (No condensation) 0. kg kv AC min (Between AC power supply terminal, E terminal, and relay contact terminal) 00 V DC0 MΩ or higher 0 Hz: 0 ms khz: 0. ms 0 Hz: 0 ms khz: 0 ms Compliant with JIS C 09. Endurance vibration: Displacement amplitude 0. mm0 to Hz, axial directions Malfunction vibration: Displacement amplitude 0. mm0 to Hz, axial directions KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

28 / Controller INFORMATI KCX-W/WM Operation Operation A-type Operation (Specific Time Output Operation) - Counting is enabled 0. sec after the power is turned on. - If an input of. to 0 V is applied to counting inhibit input terminal during counting, the counting input can be interrupted to stop counting. - If the counting inhibit input is removed, counting will resume. When the counting input number reaches the first set value (count up), output is produced. Since the first set output is only for B-type operation, the output is retained by itself. - When the counting input number reaches the second set value, the second set output is produced. At this time, when the counter counts up, the counting circuit and the counting display are automatically and simultaneously reset, thus counting will resume. - At the same time that the second set output becomes 0, the first set output also becomes 0. - If an input of. to 0 V is applied to external reset input terminal during counting, the discrete value is reset to 0. Moreover, at this time, if the counter counts up in the first setting or both the first and second setting, the output is also reset. - The KCX-WM has a power failure memory function that can memorize the discrete value and the output state if the power is shut down. - In the case of the KCX-W, if the power is supplied after being shut down for 0. sec or longer, the power source reset circuit operates to reset the discrete value and the output. B-type Operation (Self-holding Output Operation) - Counting is enabled 0. sec after the power is turned on. - If an input of. to 0 V is applied to counting inhibit input terminal during counting, the counting input can be interrupted to stop counting. - If the counting inhibit input is removed, counting will resume. When the counting input number reaches the first set value (count up), output is produced. Since the first set output is only for B-type operation, the output is retained by itself. - When the counting input number reaches the second set value, the second set output is produced and retained by itself. - When an input of. to 0 V is applied the external reset input terminal, the discrete value and the output are reset. - The KCX-WM has a power failure memory function that can memorize the discrete value and the output state if the power is shut down. - In the case of KCX-W, if the power is supplied after being shut down for 0. sec or longer, the power source reset circuit operates to reset the discrete value and the output. Normal type When resetting the counting: Add the external reset signal. Or shut down the power source temporarily (0. s or longer). Normal type When resetting the counting: Add the external reset signal. Or shut down the power source temporarily (0. s or longer). Power Source Count Input Second Set Value Discrete Value Disabled Count Input First Set Output 0 ms to s Second Set Output External Reset Input First Set Value t0. s t0. s Power Source Count Input First Set Value Discrete Value Disabled Count Input First Set Output Second Set Output External Reset Input Second Set Value t0. s t0. s KCV Retentive memory type When resetting the counting: Add the external reset signal. Retentive memory type When resetting the counting: Add the external reset signal. KCX Power Source Power Source KCM Count Input Discrete Value Disabled Count Input First Set Output Second Set Output External Reset Input 0 ms to s Second Set Value First Set Value Count Input First Set Value Discrete Value Disabled Count Input First Set Output Second Set Output External Reset Input Second Set Value KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

29 / Controller Terminal Assignment Terminal Number Symbol Description + V Power source for sensor IN Count Input (Low speed / High speed switch change) INH Disabled count input E Ground OUT Non-contact output OUT Non-contact output R External reset input 9 0 OUT OUT 0 to V AC 90 to V AC 0 V AC Contact output (a-contact) Contact output (a-contact) AC power input Terminal Connections Connection of Counting Input. In the case of contact input signals Change the switch setting on the back to low speed + input + V(0 Hz). Count Count Input Input (: (: Count) Count) Count Input (: Count) Reset Reset Input Input (: (: Reset) Reset) Reset Input (: Reset) IN (0Hz) IN (0Hz) + V IN (0Hz) () () () R. In the case of no-contact input signals The counting input can be selected from low-speed input and high-speed input... kω kω or or lower lower.. kω kω or or lower lower When used as shown in the figure below, the voltage and current that flow through the contact point are around ma. Therefore, the use of the contact point for minute electric current improves reliability. Since the contact point of the electromagnetic switch is designed for large current and high voltage, it is not suitable for use for contact input of the counter. R + + V Count Count Input Input IN IN E R () () + + V KCX ma KCX ma IN IN (0 (0 Hz) Hz) () L: 0. V or lower H: V or higher Load Connection of the Output. Contact L: 0. V output or lower H: V or higher. ma or Load lower OUT Load 9. ma or lower Load 0 Load OUT The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. Transistor : Counting is Prohibited. Load Load The contact output allows only a-contact for both the first setting and the second setting.. Non-contact output Source load Load Load Load Load Connection of a Counting Prohibit Input KOYO ELECTRICS INDUSTRIES CO., LTD. () INFORMATI KCV Disabled Count Input. In the case of contact input signals (: Counting is Prohibited.) () If counting is prohibited for the contact signal, the counting input can be used KCX only for low-speed input. KCM + V Count Input IN (0 Hz) Disabled Count Input (: Counting is Prohibited.) (). In the case of no-contact input signals KCX-W/WM. ma or lower. ma or lower E OUT OUT E OUT Power Source for Load OUT () Power Source for Load () () V or lower ma () (Up to 0 ma) OUT L: 0. V or lower ma (Up to 0 ma) OUT H: V or higher L: 0. V or lower When E () V the sink current is 0 ma: or lower V or lower. ma or lower Load OUT. ma or lower Load OUT ma () (Up to 0 ma) OUT Sink load ma (Up to 0 ma) OUT L: 0. V or lower When the sink current is 0 ma: V or lower V or lower ma () (Up to 0 ma) OUT ma (Up to 0 ma) OUT L: 0. V or lower When the sink current is 0 ma: + V V or lower Count Input IN (0 Hz) Load Load V. kω Count or lower Input IN Counting Signal Transistor : Counting is Prohibited. V. kω Count or lower Input IN Counting Signal () () () Connection

30 / Controller INFORMATI KCX-T Features Green Display Total - Maximum counting speed KCX-T: for both 0 Hz and khz KCX-T: for both 0 Hz and khz KCX-T: for both 0 Hz and 0 khz - An easy-to-see, bright green color is used for the numerical display. The total counter realizes enhanced usability with a wide range of voltages and plethora of functions. KCV KCX KCM Features Easy-to-see Green Display The numerical display is an easy-to-see green display. (Green LED with mm high characters) Counting Input can be Prohibited. By applying input to the counting input inhibit terminal, counting input can be interrupted to stop counting. Retentive Memory without Battery Backup An EEPROM is used for memory storage and a battery that does not require maintenance is used. A Wide Range of Supply Voltage Since the KCX-T has a wide input voltage range of. to 0 V DC, it can support TTL level to the input source of a V DC system. Moreover, one model can cover the supply voltages of 90 to V AC and 0 to V AC, thus can be used for a wide range of supply voltages. Latch Functions By adding input to the latch input terminal, the discrete value at that time can be latched and displayed. When the latch input is removed, the current discrete value is displayed. Manual Reset can be Prohibited. The functions of the front manual reset button can be prohibited to prevent misoperation. Zero Suppression Function Unnecessary 0 (zeros) of high-order digits are not displayed. Built-in Power Source for Sensors Since the counter has a V DC, 0 ma built-in power source for sensors, it can be connected to proximity sensors, photoelectronic sensors, and rotary encoders. Equipped with a Dust Cover as a Standard Feature Equipped with dustproof, waterproof cover as a standard feature. The reset button can be operated from outside the cover. Dust Cover For Both Embedded and Surface-Mount Installation In the case of embedded installation, the counter can be attached to the panel simply by tightening the dedicated mounting bracket from the back side. In the case of surface-mount installation, the counter can be mounted to and removed from the F terminal (terminal block) by one-touch operation. Dedicated Mounting Brackets Stand F (Terminal Block) B Stand (Terminal Block) or Connector KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

31 / Controller Specifications Model Number KCX-T KCX-T KCX-T Digit digits digits digits Count Input Maximum counting speed For both 0 Hz/ khz For both 0 Hz/ khz For both 0 Hz/0 khz KCX-T Specifications Minimum pulse width 0 Hz: 0 ms khz: 0. ms 0 Hz: 0 mskhz: 0. ms 0 Hz: 0 ms0 khz: 0 μs Input resistance 0 Hz: kω khz: kω 0 Hz: kωkhz: kω 0 Hz: kω0 khz: kω Input voltage "L" 0 to V, "H". to 0 V INFORMATI Disabled Count Input Manual Reset External Reset Response time Input resistance Input voltage On delay: ms or less Off delay: ms or less kω "L" 0 to V, "H". to 0 V On delay: 0. ms or less Off delay: 0. ms or less With the front button (Manual reset is prohibited by short-circuiting terminals and.) Response time Input resistance On delay:.0 ms or less Off delay:.0 ms or less kω On delay:.0 ms or less Off delay:.0 ms or less On delay: 0. ms or less Off delay: 0. ms or less On delay:.0 ms or less Off delay:.0 ms or less Input voltage "L" 0 to V, "H". to 0 V EEPROMNumber of overwrite cycles: 00,000 cycles or more Storage time 0 years Retentive Feature for Power Failure Input gate response time when power failure occurs Input gate response time when the power returns 00 ms or less 00 ms or less Latch Input Power Source for Sensor Supply Voltage Use Ambient Temperature Storage Temperature Use / Storage Ambient Humidity Weight Withstand Voltage Insulation Resistance Vibration Resistance Response time 0. ms or less 0. ms or less 0. ms or less Input resistance Input voltage kω "L" 0 to V, "H". to 0 V V DC V0 maripple % (rms) or lower 90 to V AC/0 to V AC0/0 Hz VA Power-on: 0 to +0 C Memory storage: -0 to +0 C -0 to +0 C (Can be stored at -0 to +0 C for about week during transport) to % RH (No condensation) Approx. 0. kg kv AC min (Between AC power supply terminal, E terminal, and relay contact terminal) 00 V DC0MΩ or higher Compliant with JIS C 09. Endurance vibration: Displacement amplitude 0. mm 0 to Hz, axial directions Malfunction vibration: Displacement amplitude 0. mm0 to Hz, axial directions KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

32 / Controller INFORMATI KCX-T Operation Operation - Counting is enabled 0. sec after the power is turned on. - When the front manual reset button is pressed or a voltage of. to 0 V is applied to external reset terminal, the previous memorized discrete value is reset to 0. At this time, the zero suppression function works and 0s from the second digit and higher are not displayed. - When using the KCX-T at not more than 0 Hz (0 counts per second), if a counting input signal of a width of 0 ms or more is applied, or when using the KCX-T at not more than khz (not more than khz for KCX- T, not more than 0 Hz for KCX-T), if a counting input signal of a width of 0. ms (0. ms for KCX-T, 0 μs for KCX-T) or more is applied, the numerical display increases and the total number of input signals is displayed. Input terminal is used for connections of not more than 0 Hz and input terminal is used for connections of not more than khz ( khz and 0 khz). - If an input of. to 0 V is applied to counting inhibit input terminal during counting, the counting input can be interrupted to stop counting. - During counting, if an input of. to 0 V is applied to latch input terminal, the discrete value at that time is memorized and displayed. When the latch input is removed, the current discrete value is displayed. Terminal Assignment Terminal Number Symbol Description + V Power source for sensor IN (0 Hz) Counting input for low speed IN ( khz/ khz/0 khz) E Ground Counting input for high speed INH Disabled count input RD Manual reset prohibition terminal R External reset input (Not connected) 9 (Not connected) 0 L Latch input (Not connected) 0 to V AC 90 to V AC 0 V AC AC power input Operation chart Power Source Count Input Discrete Value Indicated Value Disabled Count Input Manual Reset Manual Reset Prohibition External Reset Latch Input KCV KCX KCM KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

33 / Controller Terminal Connections Connection of Counting Input. In the case of contact input signals. In the case of no-contact input signals The counting input can be selected from low-speed input and high-speed input. V. kω or lower Counting Signal V. kω or lower Reset Signal Count Input (: Count) Reset Input (: Reset) Count Input (Low speed) Reset Input (High speed) + V IN (0 Hz) R + V IN (0 Hz) () IN (High Speed) E R () Connection of a Latched Input. In the case of contact input signals When using the latch for the contact signal, only low speed input can be used as the counting input. Count Input + V IN (0 Hz) () 9 L 0. In the case of no-contact input signals The counting input can be either low speed input or high speed input. Count Input IN (0 Hz) IN (High Speed) E () 9 L 0 KCX-T Connection Latch Input : Latch V. kω or lower Transistor : Latch INFORMATI When used as shown in the figure below, the voltage and current that flow through the contact point are around ma. Therefore, the use of the contact point for minute electric current improves reliability. Since the contact point of the electromagnetic switch is designed for large current and high voltage, it is not suitable for use for contact input of the counter. How to Prohibit Manual Reset + V ma () IN (0 Hz) Connection of a Counting Prohibit Input. In the case of contact input signals + V Count Input Manual Reset Prohibition Input : Prohibit IN (0 Hz) IN (High Speed) E RD R () 9 0 KCV KCX KCM Count Input IN (0 Hz) () Disabled Count Input (Counting is Prohibited) INH. In the case of no-contact input signals The counting input can be either low speed input or high speed input. V. kω or lower Count Input Transistor : Counting is Prohibited. IN (0 Hz) IN (High Speed) The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. E INH () KOYO ELECTRICS INDUSTRIES CO., LTD. 9

34 / Controller INFORMATI KCX-B Features High Speed Increment-Decrement, Single, Double Preset - Maximum counting speed: for both 0 Hz and 0 khz - The -digit preset electronic counter with the green display can be used for operations in both the increment mode and the decrement mode. - In increment to the operation as a conventional preset counter, the KCX-B has a comparative operation mode and can be used for counting and identifying items. The KCX-B can switch between positive logic and negative logic for input and output, and can be connected to source and sink input/output. KCV KCX Features Switchable to Count Up and Down The operation mode can be switched between increment and decrement. The KCX-B can be used for a wide range of applications including highprecision sizing cutters and winding machines. Increment Decrement P P OUT OUT Increment Decrement P P OUT OUT Equipped with a Dust Cover as a Standard Feature All models are equipped with a dust cover as a standard feature, and the setter can be operated from outside the dust cover. High Speed Response of 0 khz The KCX-B has a miniature design of x mm but enables high-speed counting of 0 khz. Since the counting speed can be changed to 0 Hz, the KCX-B can be also used for contact input. Supports -phase Phase Difference Input / Addsubtract Individual Input. Other than rotary encoders, input devices such as proximity sensors and relay contacts can be used. In the case of add-subtract individual input, since both increment input and decrement input can be simultaneously input, the KCX-B can be used to manage the quantity of workpieces on conveyers and the numbers of cars in parking lots. Wide-ranging Output Operation Mode Select Function The output operation mode can be switched using a rotary switch on the back. In increment to conventional coincidence output operation, kinds of output operation modes for the single setting type and 0 kinds of output operation modes for the double setting type can be selected, including comparative output operation. KCM 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

35 / Controller KCX-B Specifications Specifications Model Number Available number of Presets Standard KCX-B KCX-BW Retentive Memory Type KCX-BM KCX-BWM Single Double Digit digits digits INFORMATI Maximum counting speed 0 Hz Changed by switch 0 khz Count Input Input resistance Input voltage Response time Positive logic input:. kω Negative logic input:. kω "L" 0 to V, "H" to 0 V On delay: μs or less Off delay: μs or less Disabled Count Input Input resistance Positive logic input:. kω Negative logic input:. kω Input voltage Response time "L" 0 to V, "H" to 0 V On delay: ms or lessoff delay: ms or less External Reset Input Input resistance Positive logic input:. kω Negative logic input:. kω Input voltage "L" 0 to V, "H" to 0 V Automatic Reset Reset time 0 μs or less Number of circuits circuit circuit Non-contact Output During output of positive logic During output of negative logic Voltage: to V (No-load voltage V) Current: ma or lower Load voltage: V or lower Load current: 0 ma or lower Residual voltage:. V or lower Contact Output Number of circuits transfer contact (c) N.O. contact Contact capacity 0 V ACA (Resistance load) Electrical life 00,000 times or more (Resistance load) Mechanical life 0 million times or more Input/Output Response Time Non-contact output Contact output 0 Hz: Approx. 0 ms 0 khz: Approx. 0 μs 0 Hz: Approx. 0 ms 0 khz: Approx. 0 ms Power Source Reset KCX-B KCX-BW Power supply shutdown time Reset time* 00 ms or more 00 ms or more KCV EEPROMNumber of overwrite cycles: 00,000 cycles or more KCX Power Failure Memory Function KCX-BM KCX-BWM Storage time Input gate response time when power failure occurs Input gate response time when the power returns 0 years 0 to 00 ms 0 to 00 ms KCM Power Source for Sensor Withstand Voltage Vibration Resistance Noise Resistance Supply Voltage Use Ambient Temperature Storage Temperature Use / Storage Ambient Humidity V DC (0 to V) 0 ma kv AC min (Between AC power supply terminal, E terminal, and relay contact terminal) Compliant with JIS C 09. Endurance vibration: Displacement amplitude 0. mm 0 to Hz, axial directions Malfunction vibration: Displacement amplitude 0. mm0 to Hz, axial directions μs width, square-wave pulse, kv 90 to V AC, 0 to V VA -0 to +0 C -0 to +0 C (Can be stored at -0 to +0 C for about week during transport) to % RH (No condensation) Weight Approx. 0. kg * Time until the counting is enabled after the power is turned on The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

36 / Controller INFORMATI KCV KCX KCM KCX-B Operation Operation Various operation modes can be selected using the DIP switches and the 0-poistion rotary switch on the back of the case. SW SW SW SW Input Operation Switching (SW to ) The DIP switches are used for setting the input operation of the counter, enabling the switching of input speed, counting method, add-subtract mode, and logic. Output Operation Switching (SW) The 0-poisiton rotary switch is used for selecting the operation mode of the counter. By the operation of this switch, output operations can be selected for the single preset type and 0 output operations can be selected for the double preset type. Operation chart - Operation of the 0 position Increment Mode - Operation of the position Increment Mode A B SW 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Switch Number Function Position Operation Counting input speed Counting system operation mode Input/Output logic Position OUT 9 A B A B A B A B 0 Hz 0 khz Individual increment and decrement input -phase phase difference input Decrement mode Increment mode Negative logic Positive logic OUT Counting Output Counting Output 0 Holding Continuous Holding 0 to Reset,000 ms Continuous Holding Continuous 00 ms 0 to Reset,000 ms CP CP PCP CP C0 9 PCP CP C: Discrete valuep: First set valuep: Second set value Second Set Value First Set Value Count Value 0 OUT OUT Reset Second Set Value First Set Value Count Value 0 OUT OUT Reset 0 to 000 ms Decrement Mode Counting Maximum Value ( digits ) Decrement Mode Counting Maximum Value ( digits ) 0 to 000 ms - Operation of the position Increment Mode Second Set Value First Set Value Count Value 0 OUT OUT Reset - Operation of the position Increment Mode Second Set Value First Set Value Count Value 0 OUT OUT Reset - Operation of the position Increment Mode Second Set Value First Set Value Count Value 0 OUT OUT Reset - Operation of the position Increment Mode Second Set Value First Set Value Count Value 0 OUT OUT Reset - Operation of the position Second Set Value First Set Value Count Value 0 OUT OUT - Operation of the position Second Set Value First Set Value Count Value 0 OUT OUT - Operation of the position Second Set Value First Set Value Count Value 0 OUT OUT - Operation of the 9 position Second Set Value First Set Value Count Value 0 OUT OUT Latest catalog (free) is available online. 0 to 000 ms Decrement Mode 0 to 000 ms Decrement Mode Counting Maximum Value ( digits ) 00 ms 00 ms Decrement Mode Counting Maximum Value ( digits ) 00 ms 00 ms 0 to 000 ms 0 to 000 ms Decrement Mode 00 ms 00 ms 0 to 000 ms 0 to 000 ms Counting Maximum Value ( digits ) Visit our website

37 / Controller Terminal Assignment KCX-B/BM Terminal Number Symbol Description + V0 ma Power source for sensor IN A Count input A IN B Count input B E Input/Output minus common IN H Disabled count input (Not connected) R External reset input OUT Non-contact output 9 COM Contact output common 0 N.O. Contact output normally open N.C. Contact output normally closed + V 0 to V AC 90 to V AC For Increment INA 0 V AC For Decrement INB KCX-BW/BWM Terminal Number Symbol E Power source input SW: B SW: A SW: A Description Terminal Connections Connection of Counting Input. In the case of a proximity sensor / photoelectronic sensor Negative logic The sensor output is an NPN open collector. For Increment For Decrement + V INA INB E Positive logic The sensor output is an PNP open collector. For Increment For Increment For Decrement For Decrement SW: B SW: A SW: A + V + V INA SW: B INA SW: A SW: SW: B INB SW: A INB E SW: A E + V0 ma Power source for sensor. Switch / relay IN A Count input A Negative logic IN B + V Count input B + V + V For E Increment Input/Output minus common For Increment + For Increment OUT INA First set non-contact output For Increment For Increment INA SW: BA For Increment INA SW: For Decrement INA OUT Second SW: A For Decrement set non-contact output SW: SW: AB For Decrement INB SW: A For Decrement SW: For Decrement INB SW: SW: BA R External reset input For Decrement INB SW: SW: A INB SW: A IN H E Disabled count input E E 9 COM Contact output common 0 N.O. First set contact output (N.O.) N.O. Second set contact output (N.O.) Positive logic 0 to V AC 90 to Red V AC + V Power source input + V + + V For Increment For Increment 0 V AC Red Green For Increment + V INA INA INA SW: A INA SW: A For Decrement White SW: SW: BA For Decrement Green SW: For Decrement INA SW: A INB SW: B White SW: A INB SW: A INB SW: INB SW: B Black SW: A SW: B E INB E Black E E KCX-B Connection INFORMATI KCV KCX KCM Fo Fo Fo Fo. Rotary encoder When the TRD-J-RZ is used, SW can be in either position A or position B. Red Green White Black NPN Open Collector + V INA INB E INB INH E SW: B SW: B SW: A Red Green White Black PNP Open Collector NPN Open Collector + V + V INA INB INA EINB INH E INH SW: B SW: SW: B SW: A INB + V INB E INA SW: E + V INH A + V INH INH INB SW: B SW: A NPN Open Collector + INH V INH INA COM 9 INA E COM 9 NPN Open Collector INA COM INB N.O. 0 INB INH N.O. 0 9 NPN Open Collector PNP PNP Open Open Collector Collector NPN Open Collector INB E N.O. 0 KOYO ELECTRICS INDUSTRIES CO., LTD. The specifications and prices described in this catalog were valid when the catalog was issued. SW: A E GENERAL CATALOG SW: B 0 For the latest information, contact our sales persons or see our website. SW: A

38 NPN Open Collector or Contact Point INFORMATI KCV KCX KCM Up to V p to 0 ma elay Drive Unusable ower Source for Load p to V p to 0 ma elay Drive Unusable + V For Decrement INB SW: A + + V V INH NPN Open For Collector Increment For Increment INA + / V Controller INA E SW: COMB9 For Increment INA SW: A For Decrement SW: For Decrement INB INB INA SW: N.O. B SW: 0 SW: A For Decrement INB SW: E SW: A + EINB V SW: INH B NPN Open Collector E SW: A KCX-B INA E COM 9 E Connection + V INB + V N.O. 0 INH For Increment E INA For Increment INA SW: A For Decrement SW: B + V SW: SW: A INB SW: A For Decrement R SW: For Increment Connection of a Counting Red INB SW: B + Prohibit V input INA. KCX-B/BM E SW: A For Decrement Green E Negative logic INA SW: A SW: A White INB SW: SW: B E SW: B INB Black INB E INH E NPN Open Collector or Contact Point SW: A Red INH R + V E For Increment Green INH INA White SW: NPN Open Collector SW: A For Decrement B NPN Open Collector or SW: A SW: SW: A B INB Contact Point SW: B Black R Positive logic E INB + V Up to 0 ma + V OUT ESW: A Relay Drive Unusable INA SW: A INA COM 9 INH INB SW: B INB E E Power Source for Load NPN Open Collector Up to V INH PNP Open Collector INB E + V OUT SW: A. KCX-BW/BWM INH + V INA COM 9 Negative logic INA INB SW: B NPN Open Collector INB E + + V E V OUTINH NPN Open Collector + V INH INA COM INA COM9 INH 9 PNP Open Collector INA COM INB 9 INB N.O. 0 INB N.O. 0 PNP Open Collector E E + V SW: A INA SW: B + V SW: INH B Positive NPN Open logic E INB Collector INA COM 9 Load N.O. E INB N.O. + INHV INH 0 Load N.O. PNP Open Collector E INA COM 9 SW: A INB N.O. 0 PNP Open Collector + E V E Up to 0 ma SW: B INH Load N.O. NPN Open Collector or Up to V Contact Point Load Connection of the Reset N.O. + RInput V INH Up to 0 ma Negative logic E Up to 0 ma INA COM 9 Load INB N.O. PNP Open Collector N.O. E R SW: A 0 Up to V NPN Open Load Collector or SW: B N.O. Contact Point INH Up to 0 ma + V SW: B NPN COMOpen 9 Collector or Contact Point Power Source for Load R N.O. 0 Load N.C. Load SW: A Positive logic R NPN Open Collector COM or SW: B 9 + V Contact Point N.O. 0 + Load V OUT to V + V OUT INA COM 9 N.C. Load INA COM 9 COM 9 INB INB E N.O. 0 Load E R N.C. NPN Open Collector or Load SW: B Contact Point + V OUT INA COM 9 Up to 0 ma Up to 0 ma NPN Open Collector or For Decrement INB SW: B Contact Point + + V V INH R For Increment INAE COM 9 INA SW: A For Decrement INB E N.O. SW: A0 PNP Open Collector SW: A INB INH SW: B + V INH NPN Open Collector or E Contact Point + V INA COM 9 R + V INB N.O. 0 PNP Open Collector For Increment SW: A SW: A SW: B E INA For Decrement SW: A INH INB Connection NPN Open Collector of a or Non-contact Output Contact Point. KCX-B/BM E R R Negative logic SW: B + V NPN Open Collector or Contact Point Up to 0 ma + V OUT SW: A Relay Drive Unusable INA COM 9 INB + V E Power Source for Load Up to V R NPN Open Collector or + VSW: B OUT Contact Point INA COM 9 Positive logic INB + V to V + V OUT E R INA Up to ma NPN Open Collector or SW: B Contact INA Point COM 9 INB SW: B + V OUT INB E INA COM 9 E INH PNP Open Collector INB + V E INA to V Up to 0 ma + V OUT Up to ma Relay Drive Unusable INB SW: B. KCX-BW/BWM INA COM 9 Negative logic E E Up to 0 ma INB Load N.O. INH Power Source for Load Up to V PNP Open Collector to V Up to 0 ma E Up to V + V OUT Load N.O. + V INH Up to ma Relay Drive Unusable Up to 0 ma INA COM 9 INA COM 9 INB INB N.O. 0 PNP Open Collector E Power Source for Load Up to 0 ma E Up to V Load N.O. Up to V SW: B Load N.O. Up to 0 ma + V INH E Up to ma INA COM 9 Load N.O. Positive logic E Up to 0 ma INB N.O. 0 Load PNP N.O. Open Collector Up to ma Load N.O. Up to V Load N.O. SW: B Up to 0 ma Load Load Load COM 9 + V E N.O. 0 Up to Load ma Load N.O. N.C. Load Load Up to ma 0 V AC A N.O. COM 9 E Up to ma + V Load N.O. R Connection NPN of Open the Collector Contact N.O. or 0 Output Load Contact Point Load. KCX-B/BM N.O. Up to ma N.C. Load COM 9 N.O. 0 Load COM 9 N.O. Load N.O. 0 R Load Power Source for Load 0 V AC A NPN Open 0 V Collector AC A or SW: B Contact Point N.C. Load 0 V AC A COM 9 Power Source for Load Power to Source V for Load Up to 0 ma. KCX-BW/BWM + V OUT Up to ma Relay Drive Unusable N.O. 0 Load Up to ma INA N.O. Load COM 9 0 V AC A COM 9 INB 0 V AC A Power Source for Power Load Source for Load Power Source for Load E Up to V N.O. 0 Load Load Load N.O. Up to 0 ma Load to V + V OUT Up to ma 0 V AC A Relay Drive Unusable 0 V AC A INA COM 9 KOYO ELECTRICS INDUSTRIES CO., LTD. to V INB Visit our website GENERAL CATALOG INB + V 0 OUT Up to ma Latest catalog (free) is available online. E Power Source for Load E INA COM 9 Up to V Load Load Load Load Power Source for Load SW: B Power 0 Source V AC for Load A SW: A SW: B SW: B Load Load Load Load Power Source for Load Up to 0 ma Relay Drive Unusable Power Source for Load Up to V Up to 0 ma Relay Drive Unusable Power Source for Load Up to V Load Load NPN Open Co Contact Point Up to Up to ma

39 / Controller KCX-B INFORMATI KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

40 / Controller INFORMATI Press KCX-BT Features Display the Number of Press High Speed Increment-Decrement Limit Switch Total - Maximum counting speed: for both 0 Hz and 0 khz - The KCX-BT is an increment-decrement type counter that enables counting from positive range to the negative range. The total Rotary Encoder counter with green display can be used for displaying the current position for positioning devices. - The KCX-BT is equipped with counting inhibit input and reset Table Position Display button function inhibit input, and supports the input of both positive logic and negative logic. Features High Speed Increment-Decrement Total of 0 khz Response The KCX-BT has high speed response, which is exceptional as a total counter. Since the counting speed can be switched to a low speed of 0 Hz, the counter can be used for a wide range of applications. Minus Zone 0 Plus Zone Press Equipped with a Dust Cover as a Standard Feature All models are equipped with the dust cover as a standard feature, and the reset button can be operated from outside the dust cover. Dust Cover Dust Cover Limit Switch Display the Number of Press Supports -phase Phase Difference Input / Addsubtract Individual Input Other than rotary encoders, input devices such as proximity sensors and relay contacts can be used. In the case of add-subtract individual input, since both increment input and decrement input can be simultaneously input, the KCX-BT can be applied to manage the quantity of workpieces on conveyers and the numbers of cars in parking lots. KCV Rotary Encoder Table Position Display Input Logic Switching Functions that Operate for All Sensors Since the input logic can be switched between positive logic and negative logic (only negative logic operation for low speed reset input), the KCX-BT can use both PNP open collector output and NPN open collector output. KCX Positive Logic Negative Logic KCM Positive Logic Negative Logic Counting Across from Positive Range to Negative Range is Possible IN IN Contact Since Input the KCX-BT enables counting in the minus zone, it can display a E E range twice as large as counters that can count only in the plus zone. Minus Zone + 0 V Plus Zone + V Non-contact IN IN Input E E PNP Open Collector NPN Open Collector Contact Input Non-contact Input IN E + V IN E PNP Open Collector IN E + V IN E NPN Open Collector Equipped with High Speed and Low Speed Reset Input The two reset inputs operate in AND conditions. Therefore, for example, the counter does not require an external circuit even when performing origin correction at high speed by combining the origin pulse of a rotary encoder and the origin limit switch of a machine. Count Input A-phase B-phase Rotary Encoder Z-phase High Speed Reset Input Origin Limit Low Speed Reset Input Proximity Sensor KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

41 / Controller KCX-BT Specifications Specifications Model Number KCX-BT Digit digits Counting Range -999,999 to +999,999 Maximum counting speed 0 Hz 0 khzchanged by switch INFORMATI Count Input Input resistance Positive logic input:. kω Negative logic input:. kω Input voltage "L" 0 to V, "H" to 0 V Disabled Count Input Response time Input resistance On delay: μs or less Off delay: μs or less Positive logic input:. kω Negative logic input:. kω High Speed Reset Input Input voltage Response time Input resistance "L" 0 to V, "H" to 0 V On delay: μs or less Off delay: μs or less Positive logic input:. kω Negative logic input:. kω Input voltage "L" 0 to V, "H" to 0 V Low Speed Reset Input Manual Reset Response time Input resistance Input voltage On delay: 0 ms or less Off delay: 0 ms or less Only negative logic input:. kω "L" 0 to V, "H" to 0 V With the front button (Manual reset is prohibited by short-circuiting terminals and.) Storage time EEPROMNumber of overwrite cycles: 00,000 cycles or more 0 years Retentive Feature for Power Failure Input gate response time when power failure occurs Input gate response time when the power returns 0 to 00 ms 0 to 00 ms Power Source for Sensor Withstand Voltage Vibration Resistance Noise Resistance Supply Voltage Use Ambient Temperature Storage Temperature Use / Storage Ambient Humidity Weight (g) V DC (0 to V) 0 ma kv AC min (Between AC power supply terminal and E terminal) Compliant with JIS C 09. Endurance vibration: Displacement amplitude 0. mm0 to Hz, axial directions Malfunction vibration: Displacement amplitude 0. mm0 to Hz, axial directions μs width, square-wave pulse, kv 90 to V AC, 0 to V VA -0 to +0 C -0 to +0 C (Can be stored at -0 to +0 C for about week during transport) to % RH (No condensation) Approx. 0 g KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

42 / Controller INFORMATI KCX-BT Operation Operation Various operation modes can be selected using the DIP switches on the back of the case. SW SW SW SW Input Operation Switching (SW to ) The DIP switches are used for setting the input operation of the counter, enabling the switching of input speed, counting method, and logic. Switch Number Function Position Operation Counting input speed IN A Counting input speed IN B Counting system Input logic A B A B A B A B A B 0 Hz 0 khz 0 Hz 0 khz Add-subtract individual input -phase phase difference input Negative logic Positive logic Terminal Assignment Terminal Number Symbol Description V DC0 ma Power source for sensor IN A Count input A IN B Count input B E Input common IN H Disabled count input RD Manual reset prohibition input RH External reset input: High speed RL External reset input: Low speed 9 (Not connected) 0 (Not connected) (Not connected) 0 to V AC 90 to V AC 0 V AC Power source input KCV KCX KCM KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

43 Adding Subtracting Adding Subtracting Terminal Connections Connection of Counting Input Red. In the case of a proximity + sensor V / photoelectronic sensor Negative logic Green INA + V / Controller Green The sensor output is an NPN open collector. INA + V White White INB Adding SW: B Adding SW: B SW: B SW: B INB INA E + V INB INA Black SW: SW: AB Black SW: SW: AB Subtracting SW: SW: A Subtracting INH SW: A Adding EINB SW: INA A EINB SW: A SW: A SW: B SW: B E SW: B Subtracting E INB SW: A SW: A NPN Open Collector E Positive logic The sensor output Red is an PNP open INB collector. + V Green E INA White INH Adding Adding INB Black Subtracting Subtracting NPN Open Collector E. Switch / relay Negative logic Positive logic + V Red + V + V Adding INA Green INA + V SW: A + V INA SW: A SW: A Subtracting White SW: SW: BA INB SW: A INB SW: SW: AB INA Adding SW: A INA SW: B INB SW: SW: Black SW: B A E SW: B E SW: B INB SW: A Subtracting E INB SW: A SW: A SW: B E E + SW: A V SW: B SW: INA B INA SW: B SW: SW: B SW: SW: B INB INB SW: SW: A SW: B SW: A E Connection of a Counting Prohibit Input Red Negative logic + V Positive logic INB + V EINA E + A V NPN Open Collector INB SW: B INH Adding INA E SW: A SW: B SW: B Subtracting INH NPN INB SW: A PNP Open Collector SW: B E High Speed Reset Input Connection of the Reset Input Negative logic Low Speed Reset Input + V + V PNP Open Collector E + E + V INB + V + NPN Open Collector Adding Adding INA NPN Open Collector Adding Adding INA SW: B Adding INA INA E SW: INA INA SW: B E SW: B Subtracting SW: A SW: SW: A SW: A Subtracting SW: B SW: Subtracting SW: B Subtracting INB SW: A INH INB SW: B INB SW: INB SW: SW: BA Subtracting INB SW: INB SW: A SW: A SW: SW: BA E E SW: A SW: B E E High Speed Reset Input High INH Speed Reset Input NPN Open Collector PNP Open Collector Low Speed Reset Input Low Speed Reset Input NPN Open Collector KCX-BT Connection INFORMATI PNP PNP O PNP NPN O PNP O NPN O NPN Open Collector + V + V + V Adding Red Positive logic Adding + V INA Adding INA SW: A INA Subtracting Green PNP Open Collector E INA SW: SW: A SW: A Subtracting White SW: Subtracting + V INB SW: A SW: A INB SW: SW: A INB SW: B SW: A SW: INB SW: A E SW: B Black SW: EA SW: B SW: B E E E KCV KCX KCM High Speed Reset Input. Rotary encoder When the TRD-J-RZ is used, SW can be in either position A or position B. Low Speed Reset Input Red + V NPN Open Collector High Speed Reset Input Low Speed Reset Input Green White Black NPN Open Collector INA INB INB E E INH SW: B SW: B SW: B SW: A PNP Open Collector + V INA INB E INH SW: B + V INB + V INA E INA PNP Open Collector E INB SW: B SW: A + V INH INB SW: B NPN Open Collector E E SW: A INH SW: B PNP Open Collector INH NPN Open Collector PNP Open Collector The specifications and prices described in this catalog were valid when the catalog was issued. High Speed Reset Input For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. High Speed Reset Input Low Speed Reset Input Low Speed Reset Input NPN Open Collector 9

44 / Controller Commonly Used in KCX Series The correct way to use INFORMATI How to Change and Extend the Output Time (For the Operation of the A-type) In the operation of the A-type (specific time output type), the output time can be changed in the range from approx. 0 to,000 ms using the volume on the front of the counter (on the back for the KCX-W/WM). Connection of the Power Supply The power transformer of the KCX series has a central voltage designed at 0/0 V. Therefore, do not make the connection as shown in the figure below. Wrong connection 0 to V AC 90 to V AC 0 V KCX Turning the volume fully counterclockwise sets the minimum output time (approx. 0 ms). Conversely, turning the volume fully clockwise sets the maximum output time (Approx.,000 ms). Moreover, in the case of the KCX single preset counter, if a capacitor is added between terminal (E) and terminal (CH), the output time can be extended as shown in the table below. 0 ms 000 ms E CH + CH () 00/0 V AC 00 V AC 0 V Correct connection 90 to V AC 0 V 00 V AC 0 V * except KCX * KCX * 0 to V AC 0 V 00/0 V AC 0 V KCX * KCV KCX KCM Applied Electrolytic Condenser Variable Resistor Minimum Output Time Changing the Operation Mode Variable Resistor Maximum No Capacitor 0 ms to s. μf V 00 ms to s. μf V 0 ms to s 0 μf V 0 ms to s μf V 00 ms to 0 s Before changing the operation mode, turn the power off. And, after the power is turned off, add the reset input once. If the reset input is not added, the output may not be produced even if the set value is reached or the counter may count up at the set value that existed prior to the change or at a value irrelevant to the set value. Changing the Set Value The output may be produced if the set value is changed during counting. Therefore, before changing the set value, turn the power off and add the reset input. If the setting is changed during operation, the output may not be produced even if the set value is reached or the counter may count up at the set value that existed prior to the change or at a value irrelevant to the set value. In the case of the KCX-DM, KCX-WM, KCX-BM, and KCX-BWM (equipped with a power failure memory function), the discrete values are memorized even if the set value is changed after the power is turned off. In this case, after the power is turned on, add the reset input once. If the reset input is not added, the output may not be produced even if the set value is reached or the counter may count up at the set value that existed prior to the change or at a value irrelevant to the set value. "0" (zero) setting In the case of a "0" setting (for example, "000" is set for digits), because the counting operation and the output operation become stable, note the following points. - Although the output is not produced if the counting input is "L" or the reset input is "H," the output may be produced in other cases. - If the reset input is "L" and the counting input is consecutively input, 0,,, and appear as the counting (indicated value) in the B-type operation. This same operation may take place in A-type operation. Noise Measures Reflecting studies into various noises based on proprietary test methods, Koyo s' counters deliver performance that sufficiently withstands noise in normal operation. However, to enhance the reliability further, observe the following precautions when using the counters.. When using a solenoid valve, clutch, or brake near the counter, in order to prevent the occurrence of noise, connect a surge absorption element of the series circuit that consists of a capacitor (film capacitor of 0. to 0. μf) and resistance (00 Ω / W) parallel to the driving coil. R=00 Ω / W C=0. to 0. µf Capacitor C R. When using the counter in places where a lot of noise is generated, in order to prevent malfunction, as, do not bundle the wire for the power source line (AC) and the input/output signal line of the counter with wire that contains the high current wire, and use shielded wire for the input/ output signal line. Moreover, the shield jackets of all shielded wire should be connected to the E terminal of the counter. When a sensor and the counter are mounted to separate frames, connect the frames with a thick conducting wire (0. mm or thicker). Sensor + V OUT E Frame A Shielded Cable (Connect Using Thick Conducting Wire.) + V IN E (G) Frame Earth Frame B 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

45 / Controller Commonly Used in KCX Series Precautions. Connect the E terminal of the counter to the frame over the shortest distance. When the counter uses a common ground with other devices, make the ground line as short and thick as possible, and connect the only one ground to the frame. Also, separate the ground line of the counter from other ground lines in which high current flows. Other Device () Other Device () E E E Frame Earth Other Ground for Large Current Frame. When adding a contact signal such as an electromagnetic relay to the counting input terminal for low speed, inserting a resistor (0Ω/W) between the counting input and ground prevents malfunctions by contact failure, and enhances reliability further. Meanwhile, when carbide is generated on the surface of the contact point by glow discharge that occurs when the inductive load is opened/closed, the contact point produces adverse effects such as higher contact resistance. When the current that flows through the contact point is large, the electric discharge becomes the arc discharge and blows off the carbide that occurs when the contact point is opened/closed. As a result, clean metal is always exposed on the surface of the contact point and the contact resistance is maintained at a stable low value. However, when little current flow through the contact point and, in particular, the working voltage is low, the discharge to be generated when the contact point is opened/closed becomes only glow discharge. In this case, carbide is generated and adheres to the surface of the contact point, and the surface cleaning effect is lost. As a result, contact failure occurs at a number of opening/closing cycles that is much lower than the number estimated from the life curve in the figure above. Therefore, if an inductive load is used at low voltage and low current, unless the occurrence of glow discharge is prevented, the contact point incurs a contact failure at one-tenth to one-hundredth of the life estimated from the figure above. As glow discharge preventive measures, as shown in the figure below, surge voltage should be absorbed by using a CR-type surge absorption element or varistor in parallel with the load or a diode in the case of a DC load. - Surge absorption circuit Contact Point Contact Point INFORMATI Electromagnetic Contactor 0 Ω / W + V IN E Precautions Cautions Concerning the Output Relay Contact As the load of the counter, inductive loads such as electromagnetic switches, control relays, AC solenoids, and solenoid valves are normally connected. The higher the current and the working voltage that flow through the output contact point of the counterworking voltage, the shorter the life of the output contact point built into the counter. The trend is as shown in the figure below. The curves in the figure below show the degree of erosion of the contact point, indicating that if the current and voltage become lower, the life becomes longer. Namely, if the working voltage and current become lower, the erosion of the contact point becomes smaller and the life of the contact point becomes longer. Contact Point R V AC or lower 0E-(IR) W0C (Hitachi) R Load Load V AC or lower - The indication of a relay contact capacity of A and A, etc. is for the case of a resistance load. In the case of an inductive load, the capacity increases by 0 to 0%. Moreover, if the load is reduced, the life of the contact point becomes longer accordingly. - Note that a non-contact output when the power is supplied (within 00 ms) or the power is shut down is unstable (neither nor 0) for both the power failure memory type and the normal type. Load Z : ZNR (Panasonic) ERZC0DK9 TNR (Marukon) TNR9GK R KCV KCX KCM - Life curve of relay (Equivalent to the NT type made by Matsushita) - Some models with numerical displays partially show numbers in different shapes as shown below, but this is not trouble Mechanical Life 0 V AC: Resistance Load V DC: Resistance Load KCX-D/D/D/D KCX-B/KCX-BT Models with a Numerical Display Except Those on the Left Life (0,000 Cycles) V AC: Coil Load V DC: Coil Load 0 Load Current (A) (Note) Under load conditions specified in JEM 0 (9) The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

46 / Controller Commonly Used in KCX Series Dimensions Dimensions Dust Cover (Unit: mm) to : Thickness of the Panel in the Case of Embedded Installation - Bore Drilling Dimensions for Stationary Installation Using a Dedicated Socket (Stand F) Stand F Panel-cut Dimensions for Embedded Installation INFORMATI F Stand, B Stand * Mounting Bracket (Screw Tightening Torque of 0. Nm or less) -M * 9 * 9. (.) ±0.. 0±0. 0 ± 0. * Dimensions When the Dust Cover is Attached - KA-0 Dedicated Connector - Stand F: KF-0 (For Stationary Installation) 0±0. Hole. - Panel-cut Dimensions for Embedded Installation Stand B: KB-0 (For Embedded Installation) (The Outside Dimensions are the Same as the KF-0.) - The KA-0, KF-0, and KB-0 are Sold Separately KCV KCX KCM Cautions for Installation - The dedicated stand F (KF-0) and stand B (KB-0) are provided with screws required for mounting. - In the case of the KA-0 dedicated connector kit and KB-0 stand B, if using screws other than those provided, use screws of the length shown below. For connector (KA-0) mm or less For stand B (KB-0) 0 mm or less If screws of a length longer than the that mentioned above are used, they may damage the element in the counter. Attachment Panel-cut Dimensions or less Square Hole or less KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

47 / Controller Commonly Used in KCX Series INFORMATI KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

48 / Controller INFORMATI KCM-0/ Series Features Consolidated (Maintenance ) - The KCM-0 series consolidates nine counters into one unit and the KCM- series consolidates eight counters (timers) into one unit. - These counters notify the maintenance period of several tools, as needed for tool replacement with machining centers and NC machine tools. - Tool management: Replacement prediction / warning - Whetstone for polishing: Maintenance prediction - Quantity management: Total counter / Preset counter - Time management: Integrating timer Features KCM-0 Series The counter features 9 counting inputs, a preset function and independent prediction output (count up output), and outputs when either one of the counters reaches the equipment stop set value. KCM- Series The counter features counting inputs, a preset function and independent prediction output (count up output), and outputs when either one of the counters (Timers) reaches the equipment stop set value. Open collector output: KCM-0 (Japanese surface sheet) KCM-0- (English surface sheet) Open collector output: KCM- (Japanese surface sheet) KCM-- (English surface sheet) Voltage output: KCM-0P (Japanese surface sheet) KCM-0P- (English surface sheet) KCV KCX KCM - Nine -digit preset counters (timers) are consolidated into one unit. - Battery-less The set value / discrete value are memorized by a maintenance-free EEPROM. - Individual prediction (preset) outputs for 9 circuits - Indications of the previous prediction (green) - prediction (orange) - facility stop (red) are distinguished by color. A previous prediction display function that notifies that the value is close to the prediction set value is built-in. - Equipment stop output An over-value is set for the prediction set value of each counter, and when any one of the counters reaches the over-value, the equipment stop is output (red display). - 9 preset counters can be used as a total counter Each counter can independently preset value s(prediction setting) and individually count the inputs and outputs against the preset value (orange display). - Oilproof front operation panel - Miniature (DIN x mm) The overall depth is mm, so the control panel is thin. - Eight -digit preset counters (timers) are consolidated into one unit. - Battery-less The set value / discrete value are memorized by a maintenance-free EEPROM. - Individual prediction (preset) outputs for circuits - Each counter (timer) displays a different color when the set value is reached. Setting (green) - Setting (orange) - Setting (red) - OR output When any one of the counters (timers) reaches the value of setting or setting, the output is produced. - preset counters can be used as a total counter or a integrating timer. The counter / timer functions can be mixed in use. - Any counter / timer can be reset by external signal. - Oilproof front operation panel - Miniature (DIN x mm) The overall depth is mm, so the control panel is thin. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

49 / Controller Application KCM-0 Series Tool Maintenance of Multiple Spindle Machine Tools 9 Processing Count Input 9 KCM-0/ Series Features KCM- Series Tool Maintenance of Multiple Spindle Machine Tools Processing Count Input Timekeeping Input INFORMATI Facility Stop Output Lamp / Buzzer /Facility Stop, etc. Prediction Output Prediction Output Prediction Output 9 OR Output Lamp / Buzzer /Facility Stop, etc. Setting Output Setting Output Output Setting Note ) s to 9 perform similar operation. ) The equipment stop output and the equipment stop display turn on when any one of the counters, to 9, reaches the equipment stop set value. Note ) s / Timers to perform similar operation. ) The OR output turns on when any one of the counters (timers), to, reaches the value of setting (setting ). Basic Operation KCM-0 KCM-0 Series Time Chart Current Values (Count Values) Current Values (Count Values) Equipment Stop Equipment Set Value Stop Set Value Prediction Set Value Prediction Set Value Previous Prediction Previous Set Value Prediction Set Value No. KCM- Series Time Chart Current Values (Count Values/Timing Value) Setting or Setting Setting /Timer No. KCM- Green Orange Count Input Green Orange Red Count Input Green Orange Red Previous Prediction/Alarm Previous Prediction/Alarm Display Display Equipment Stop Equipment Display Stop Display Prediction Output Prediction Output H () H () Facility Stop Output Facility Stop Output L () L () Reset Reset (External or Key Input) (External or Key Input) Setting /Setting Display Setting Output OR Output Reset (External or Key Input) Green Orange Green Orange Red Count/Timer Input H () L () KCV KCX KCM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

50 / Controller KCM-0/ Series Each Part Name and Function INFORMATI Panel Explanation KCM-0 Series Reset key - Resets the displayed current value. - When several counters are counting up and the reset operation is performed, the counter display switches to the next counter. Mode display - Either previous prediction, prediction, or equipment stop is displayed in the setting mode. When all the lights are turned off, the device is the operation run mode. No. display - Displays the selected counter No. - Ever y time the counter counts up (prediction set value), the counter No. switches to the No. of the counter that overflowed. Reset No. Previous Prediction Prediction Equipment Stop Setting No. Mode Selection Selection Equipment Stop Current Value Set Value Set Setting key No. selection key - Switches the display between the current value and the set value of the counter. - s that are not used in the run mode are not displayed. - If pressed and held for second or longer, the counter No. automatically changes. Count-up display (GreenOrangeRed) - Green: Shows that the value reached the previous prediction set value. - Orange: Shows that the value reached the prediction set value. - Red: Shows that the value reached the equipment stop set value. Equipment stop display (Red) - Shows that one of the counters reached the equipment stop set value. Current value display - Displays the current value of the counter by counter No. Zeros of high-order digits are out in the run mode. Set value display - Displays the set value of the counter (prediction, previous prediction, and equipment stop) by counter No. Zeros of high-order digits are out in the run mode. Setting mode selection key - Switches between the run mode and the setting mode. If there is no key entry for minute or longer, the mode automatically switches to the run mode. Key (Digit selection key) - Selects the digit for inputting the set value. - The selected digit flickers. - If pressed and held for second or longer, the digit automatically changes. KCV KCX KCM + Key (Numeric value changing key) - Changes the numeric value of the digit selected by the key. - If pressed and held for second or longer, the digit automatically changes. Set key - Enters the set value in memory in the setting mode. When the set value is entered, the set value display flickers three times, indicating the input. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

51 / Controller KCM-0/ Series Each Part Name and Function Panel Explanation KCM- Series Reset key - Resets the displayed current value. - When several counters are counting up and the reset operation is performed, the counter display switches to the next counter. Mode display - Either setting, setting, or setting is displayed in the setting mode. When all the lights are turned off, the device is the operation run mode. C/T No. display - Displays the selected counter / timer No. - Every time the counter / timer counts up (setting ), the counter / timer No. switches to the No. of the counter that overflowed. Reset C/T No. Setting [Green] C/T No. Selection Setting Setting Setting Mode Setting [Orange] Setting [Red] Current Value Setting key C/T No. selection key - Switches the display between the current value and the set value of the counter. - s/timers that are not used in the run mode are not displayed. - If pressed and held for second or longer, the counter No. automatically changes. Mode key - Switches between the run mode and the setting mode. - If there is no key entry for minute or longer, the mode automatically switches to the run mode. Red h Orange min Set Value Set Green s Count-up display (GreenOrangeRed) - GreenShows that the value reached the Setting. - OrangeShows that the value reached the Setting. - RedShows that the value reached the Setting. Timing unit display - Displays the timing unit by color during timer operation. - Green: The time unit is in seconds. - Orange: The time unit is in minutes. - Red: The time unit is in hours. Current value display - Displays the current value of the counter/ timer by C/T No. Zeros of high-order digits are out in the run mode. Set value display - Displays the set value of the counter/ timer (Setting, setting, and setting ) by C/T No. Zeros of high-order digits are out in the run mode. INFORMATI Key (Digit selection key) - Selects the digit for inputting the set value. - The selected digit flickers. - If pressed and held for second or longer, the digit automatically changes. + Key (Numeric value changing key) - Changes the numeric value of the digit selected by the key. - If pressed and held for second or longer, the digit automatically changes. KCV KCX KCM Set key - Enters the set value in memory in the setting mode. When the set value is entered, the set value display flickers three times, indicating the input. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

52 INFORMATI KCV KCX KCM / Controller IN COM Count-up Display Equipment Stop Display Count Input + V KCM-0/ Series Equipment Stop Output V DC±0% Output + IN COM Count-up Current DisplayValue Equipment DisplayStop Display Prediction + V Power Count Input No. + V Supply 0 V COM Display Set Value Display Circuit Stop Output Equipment Current Value Display Prediction Output No. OR 9 Display digits Set -stage Value Display Counting Speed Switching Input Preset V DC±0% No. Selection Input 9 9 IN COM Count-up Display Equipment Stop Display Power + OR V + Reset Input Supply Power RUN Output Count Input 9 digits + -stage V Supply Circuit 0 CPU V COM Normal Circuit + Counting Speed Switching CH Equipment Stop Output 0 V COM Input Preset OUT COM No. Selection Current Input Value Display 9 Prediction Output 9 V DC±0% Reset Input No. CPU Normal RUN Output Display Set Value Display + CH 0 * V COM V DC±% OUT COM V DC±0% or V DC±0% * IN COM Count-up Display Equipment Stop Display + V + OR Power Count Input + V Supply 0 V COM 9 digits -stage Circuit * V DC±% Equipment Stop Output Counting Speed Switching or Input Preset V DC±0% No. Selection Input IN 9 COM Count-up Current DisplayValue Equipment Display Prediction Output * Stop Display 9 + V + Power Reset Input Count Input No. + RUN V Output Supply 0 V COM CPU Normal Circuit Display Set Value Display + Equipment Stop Output CH 0 V COM Current Value Display OUT COM V DC±0% Prediction Output No. OR 9 Display digits Set -stage Value Display * V DC±% or Counting Speed Switching Input V DC±0% Preset * IN COM Count-up No. Selection Display Input Equipment Stop 9Display + V + 9 Power OR Count Input Reset Input + V Supply 0 V COM RUN Output 9 digits -stage Circuit CPU Normal Equipment Stop Output Counting Speed Switching CH Input Preset OUT COM Current Value Display Prediction Output No. Selection Input 9 9 Reset Input No. CPU Normal Display Set Value Display RUN Output CH OUT COM OR 9 digits -stage Counting Speed Switching Input Preset No. Selection Input 9 9 Reset Input RUN Output CPU Normal * Negative Logic Input CH OUT COM * Positive Logic Inpu Connection Block Diagram KCM-0 KCM-0P Function Power Supply Circuit + V 0 V COM V DC±0% + * Negative Logic Input * Positive Logic Inpu KCM-0 * Negative Logic Input KCM-0P * Positive Logic Inpu * + V DC±% or V DC±% Terminal Number Input/Output Description of Functions Specifications * + IN COM Count/Time-up Display Timer Display + V + Power C/T Input The current value of the relevant counter is added (+) + V regardless Supply of the 0 V COM,,,,,, 9, Count input * + V DC±% Circuit Counting speed 0/00 KCM-0 operation mode / setting mode. The current value changes by HL and OR Output 0, or to 9 Hz Input voltage V DC±% * + LH (positive logic). IN COM Count/Time-up Current Display Value Display Setting Output Timer Display + V + : 0 to V Power C/T Input C/T No. + V Supply 0 V COM : V or higher Counting speed : 0 Hz Switched Circuit by the edge Display Set Value Display OR Output Input resistance:. kω switching input : 00 Hz of the power supply Current Value Display Setting Output KCM-0P Input voltage selection C/T input No. OR 9 No. C/T No. Selection B0 Display digits Set -stage Value Display On delay: 0 ms (Negative logic) The counter No. changes by the counter selection input HL and LH selection input Off delay: 0 ms : 0 to V (positive B logic). In the Preset operation mode, unused counters are not selected. : Input is open B (timer) Power OR (Positive logic) BA Supply RUN Output C/T No. Selection The B0current value of the digits counter -stage designated Circuit by the counter CPU Normal No. is reset. If : to. V Reset Input On delay: 0. + s Reset Input the Bcounter No. selection Preset input and the input reset input are simultaneously * Negative : Logic 0 to Input V OUT COM Off delay: B (timer) V 0. DC±% s input for approx. seconds, all counters are reset. * Positive Input Logic resistance: Inpu. kω BA RUN Output CPU Normal KCM-,,,, 9, 0,,, Prediction The prediction output is output if the individual output of counters Nos. to Reset Input + * Negative Logic Input output to 9 9 reaches the prediction set value. Input/Output response time OUT COM V DC±% * Positive Logic Inpu 0 ms (0 Hz) 0 ms (00 Hz) Equipment stop output The equipment stop set value is output if one of the counters Nos. to 9 reaches the equipment stop set value. KCM-0 KCM-0 KCM-0P KCM-0P KCM- KCM- RUN output KCM-0 Circuit KCM-0 Input Circuit IN COM Input Circuit Input IN COM No. display V V. kω when the CPU normally operates / when the CPU does not operate normally. The counter No. selected with the counter No. selection key or by the external counter No. selection input is displayed. Every time the counter counts up, the counted counter No. switches to the counted up No. (ranked by priority). Priority: Equipment stop > Prediction > Previous prediction V Output Circuit Prediction Output Equipment Stop Output RUN Output V Output Circuit Prediction OUT COMOutput 0 V COM Equipment Up to Stop V DC/0. Output A RUN Output Response time : After the power is supplied. s or less : * Negative After an Logic abnormality Input is detected 0 ms or less * Positive Logic Inpu Notes ) IN COM and V are connected inside the counter. ) OUT COM and 0 V COM are connected inside the counter. Notes ) IN COM and V are connected inside the counter. ) OUT COM and 0 V COM are connected inside the counter. Input. kω OUT COM 0 V COM Up to V DC/0. A KCM-0 Input Circuit V Output Circuit V KCM-0P Input V Circuit IN COM IN COM V KCM-0P Input Circuit. kω Input Input. kωin COM KOYO ELECTRICS. INDUSTRIES kω CO., LTD. Input V Output Prediction Circuit V Notes ) IN COM and Output Note) V are IN COM connected and inside V are the connected counter. inside the counter. ) OUT COM and 0 V COM are connected inside the counter. Equipment Stop Output OUT COM RUN Output Output Circuit Prediction V Output OUT COM Equipment Stop Output 0 V COM Up to V DC/0. OUT A COM RUN Output Prediction Output Equipment Latest catalog Stop Output (free) is available online. RUN Output Note) IN COM and V are connected inside the counter. Visit our website

53 No. Selection Input Reset Input CH 9 CPU Normal 9 RUN Output OUT COM * Negative Logic Input / Controller * Positive Logic Inpu KCM-0/ Series Connection Block Diagram KCM- * + V DC±% or * + IN COM C/T Input C/T No. Selection B0 B B BA Reset Input Count/Time-up Display C/T No. Display Current Value Display Set Value Display digits -stage Preset (timer) Timer Display + V OR Power Supply Circuit CPU Normal V DC±% + V 0 V COM OR Output Setting Output + RUN Output + OUT COM V DC±% * Negative Logic Input * Positive Logic Inpu KCM- INFORMATI KCM-0 KCM-0P Function Input Circuit IN COM,, Input Terminal Number Input/Output Description of Functions Specifications,,,,,, 9, 0 V. kω Input Circuit,,,, 9, 0,, IN COM C/T input to V C/T No. selection input to All C/T No. selection input. kω OR output Input The counting (timing) of the relevant counter (timer) is performed regardless of the operation mode / setting mode. - When the KCM-0/ is used as a counter: The current value changes when """". - When the KCM-0/ is used as a timer: Timing range Input voltage The timing starts when """". Hour to 99,999 h (Negative logic) The timing continues while "". Minute to 99,999 m : 0 to V The timing stops when """". Second to 99,999 s Output Circuit Notes ) IN COM and V are connected inside the counter. : Input is open Prediction Output ) OUT COM and 0 V COM are connected inside the (Positive counter. logic) Equipment Stop Output The counter / timer RUN you Output want to reset is designated by three inputs (B0, B, and B). OUT COM 0 V COM Up to V DC/0. A When you want to designate all counters / timers at the time of a reset input, this input should be. Reset The current value of the selected counter / timer No. becomes 0 (zero). RUN output This is output if one of the counters / timers Nos. to reaches the setting Prediction Output (setting ) value. Equipment Stop Output RUN Output when the CPU normally operates / when the CPU does not operate normally. Counting speed 0 Hz/00 Hz Minimum pulse width. ms/ ms On delay: 0ms Off delay: 0ms V Setting Output This Circuit is output if the individual V output of counters / Note) timers IN Nos. COM and to V are connected inside the counter. output to reaches the setting OUT value. COM Input/Output response time 0 ms (0 Hz timer) 0 ms (00 Hz) : to. V : 0 to V Input resistance:. kω Response time : After the power is supplied. s or less : After an abnormality is detected 0 ms or less KCV KCX / Timer No. display function The counter No. selected with the counter / timer No. selection key or by the external C/T No. selection input is displayed. KCM KCM- Input - Default Circuitsetting: If the "mode" Vkey and the Output "+" key Circuit are simultaneously pressed, the default setting mode starts Notes to initialize ) Input the Common following data. 0 V: Positive Logic Setting Output () Selection of the counter and timer, () Setting of the counting speed and timing unit, () Prohibition/Permit selection V: of Negative the reset key, Logic and () Selection of the set value concerning the OR OR Output, RUN Output IN COM output (Setting or setting ) Open Collector ) Output Common KCM-: 0 V and Internally Short circuited OUT COM Circuit Input. kω 0 V COM KCM- Input Circuit IN COM Input. kω V Output Circuit Notes ) Input Common 0 V: Positive Logic Setting Output V: Negative Logic OR Output, RUN Output Open Collector ) Output Common KCM-: 0 V and Internally Short circuited OUT COM 0 V COM The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

54 / Controller INFORMATI KCV KCM-0/ Series General Specifications/Dimensions General Specifications (Commonly Used in KCM-0/ Series) Items Supply Voltage Power Consumption Use Ambient Temperature Storage Temperature Use / Storage Ambient Humidity Insulation Resistance Dielectric Voltage Noise Resistance Vibration Resistance Impact Resistance Case Exterior Weight Price KCM-0 KCM-0- KCM-0P KCM-0P- KCM- KCM-- Model Number (Accessories) Mounting bracket Specifications KCM-0 series: V DC0% (. to. V) KCM- series: V DC% (0. to. V) W -0 to + C -0 to +0 C (No freezing) to % RH (No condensation) 00 MΩ or higher00 V DC (Between power supply terminal and input-output terminal) 00 V AC0/0 Hz min (Between live parts and externally-exposed non-charged metal part) Between power supply terminals: kv (Pulse width μs, start-up ns) Between input terminals: 00 V (Pulse width μs, start-up ns) Malfunction vibration: Displacement amplitude 0. mm 0 to Hz, axial directions Endurance vibration: Displacement amplitude 0. mm 0 to Hz, axial directions 9 m/s, axial directions Munsell N- (dark gray) ABS material 0 g Price Open Open Terminal Assignment KCM-0 Series Equipment Stop Prediction Output Count Input RUN Operational 9 Prediction Output Speed Count Input +V 0V COM OUT COM CH IN COM KCM- Series Reset No. OR Output Setting / Setting Output C/T Input RUN N.C BA B0 Setting Output C/T Input C/T No. Selection Input +V 0V COM OUT COM B B IN COM Reset KCX KCM Dimensions (Unit: mm) Thickness of Mounting Plate to Mounting Bracket Equipment Stop Reset Current Value No. Prediction Prediction Equipment Stop Set Value Setting No. Mode Display Selection Set Square Hole KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

55 / Controller s Related Products Socket Model Number Appearance Applicable Dimensions Price Socket for Surface-Mount Installation (Terminal Block) KF-0 0 g KCX KCX-B 0±0.. Hole Open INFORMATI Socket for Embedded Installation KB-0 0 g KCX KCX-B. KB-0 TC- 9 Open Hole for -M 9 0 Open 0 The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

56 / Controller INFORMATI TC-V Series Features Digital s - The TC-V series has a compact DIN size with an easy-to-see large display. - With characters represented by bright large red LEDs, 0 mm high characters can be clearly seen from a distance and an angle. - The green LED is used for the preset value to differentiate it from the measured values. - The preset value can be easily set to 0 using the setting key corresponding to each digit, like using a digital switch. - The TC-V series can be easily operated owing to a selection method that uses DIP switches for basic functional setting and the digit keys for detailed setting. Features Protection Functions for Each Key Key protection can be set for each key to prevent unintended operation. Retentive Memory without Battery Backup An EEPROM is used for memory storage and a battery that does not require maintenance is used. Removable Terminal Block This removable terminal block improves maintenance. After wiring, the terminal block cover enhances safety. Prescale Functions The TC-V series features built-in prescale functions that can convert rotating speed into speed, flow rate, and work load per unit time. Stable Display The measuring time can be set to stabilize the display at high speed. Measuring time can be selected from 0./0./.0/.0 s. High Speed Response The measuring input is 0 khz. CE Marking Compliant Multi-voltage Power Supply for AC Type The AC type covers supply voltages of to V AC and can be used for any power source. Protection Fulfilling IP Sheet keys are used for the front panel, which enables users to safely operate the device even with wet or unclean hands. Conformity to CE and UL CE marking compliant and UL standard (UL0) certified product. High Accuracy As the measuring method, the period measurement method is used, which can realize high accuracy at low speed. "0" Display Immediately After Rotation Stops The stop judgment time that immediately displays "0" after rotation stops can be selected from 0./0./.0/.0/.0 s. With-output Model is Also Available. The single preset type is available, which supports rotation control. TC-V Zero Suppression Function Unnecessary 0 (zeros) of high-order digits are not displayed. TC- Model Number List Classification Model Number Digit Power Source Power Source for Sensors V DC, 0 ma Price Digital with Single Preset Digital Only for Display (Accessories) Mounting frame TC-VS AC Open TC-VS-C DC Open TC-V AC Open TC-V-C DC Open TC- V - - Series classification - Number of digits to display - Preset Blank : For display S : -stage preset - Power source type Blank : AC power C : DC power KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

57 / Controller General Specifications Items Rating AC Power Supply Voltage 00 to 0 V AC to V DC Allowable Power Range to V AC 0 to. V DC Power Consumption Approx. VA Approx. W TC-V Series Specifications DC Power INFORMATI Power Source for Sensors Power Failure Memory Ambient Temperature Storage Temperature Ambient Humidity Withstand Voltage V DC (0 to V) 0 ma (Ripple noise:0%p-p or lower) EEPROM -0 to 0 C -0 to 0 C (No freezing) Number of overwrite cycles: 00,000 cycles or more Storage time: 0 years to % RH (No condensation) kv AC min (AC input, 0 V, between relay contacts) (DC power supply type: 0 V, only between relay contacts) Vibration Resistance Endurance Malfunction Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Impact Resistance Endurance Malfunction 90 m/s ms, axial directions 9 m/s ms, axial directions Noise Resistance Between power supply terminals. kv (Pulse width μs, start-up ns) Between power supply terminals.0 kv (Pulse width μs, start-up ns) Protective Structure IP (Only the front panel part) Weight Approx. 0 g Approx. 0 g Conforming cable 0. to. mm Terminal Block Conforming crimp terminal R.- Allowable tightening torque 0. Nm Performance Specifications Items Rating Type Setting Single setting with prediction output/no prediction output (Different model No.) Digit digits Display Measured value display: Red LED, height of characters 0 mm. Preset value display: Green LED, height of characters mm Counting System Period measurement system Measurement Item Speed of revolution only Basic Measurement Range 0 to 999,999 rpm (When prescale is ) TC-V Prescale Functions M x 0 -n 0-9 to 999,999 M 999,999, 0 n 9 Measurement Accuracy 0.0%Excluding when low speed input (0 Hz) is selected (0.% for low-speed input) Measuring Time 0./0./.0/.0 s Input logic: Negative logic (No-voltage input)/positive logic (Voltage input ) TC- Input Input resistance: Positive logic kω Negative logic. kω (AC power)/. kω (DC power) Input voltage: "L" 0 to V "H" to 0 V Measurement Input Response External Reset *Output 0 Hz/0 khz Minimum signal width: ms Non-contact output: NPN open collector output, V 00 ma, withstand voltage: V, residual voltage:. V or lower Contact output: transfer contact point (c), 0 V AC A (Resistance load) *Output Mode Comparative output/holding output Key Protection Any key setting is enabled. Installation Method Dedicated to embedded installation (Terminal block connection) - Items with an * mark do not apply to display dedicated models. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

58 / Controller INFORMATI TC-V Series Operation Measurement Operation () Rotating speed display for pulse per revolution The reciprocal () T of the input period (T sec) of IN is multiplied by 0 and displayed as the rotating speed. * Counting range input: At the time of P/R and prescale, the range is 0 to 99,999 rpm. Display Previous Measured Value T 0 rpm T 0 rpm 0 rpm 0 rpm T T Input Single Pulse Width Low speed (0 Hz) High Speed (0 khz) H H L 0 ms or more 0 ms or more L µs or more µs or more IN T T T T () Measuring time This is used for stabilizing the display when the device rotates at high speed. The average pulse that is input during the measuring time is displayed and, if it is larger than the measuring time, the display is updated every time the pulse is input. Display Pulse Average in T Pulse Average in T 0 rpm T IN Measuring Time T T T Measuring Time Measuring Time Measuring Time Output Operation Chart * Only models that produce output Holding Output Preset Value Predicted Value 0 TC-V TC- Reset Contact Output Non-contact Output Comparative Output Preset Value Predicted Value Reset Contact Output Non-contact Output : Prediction Set Value When the prediction set value is "0," non-contact output becomes the same as the output operation of contact output. The prediction set value should be smaller than the preset value. If the prediction setting exceeds the preset value, the measured value becomes 0 and the prediction output (non-contact output) turns. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

59 / Controller TC-V Series Connection Terminal Connection Diagrams TC-VS Measurement Power Source for Sensor Input V DC, 0 ma IN Non-contact Output 0 V OUT R Reset Input TC-VS-C Non-contact Output OUT Measurement Input IN 0 V R Reset Input INFORMATI 9 0 COM N.C N.O Contact Output 00 to 0 V AC Power 9 0 COM N.C N.O + Contact Output to V DC Powert Output TC-V Measurement Power Source for Sensor Input V DC, 0 ma IN 0 V TC-V-C -C Measurement Input IN 0 V R Reset Input R Reset Input 00 to 0 V AC Power + to V DC Powert Output * Non-contact output (OUT terminal) is also used for prediction output. * Do not connect anything to unconnected terminals. Input/Output Circuit Diagrams AC power DC power Power Source for Sensor V DC Internal V During Negative Logic Input V. k 9 N.C. COM V DC + Internal V During Negative Logic Input V. k 9 N.C. COM TC-V TC- IN k k 0 N.O. IN k k 0 N.O. V. k V. k Reset Input k k OUT Reset Input k k OUT 0 V 0 V The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

60 / Controller TC-V Series Connection INFORMATI Input Connection Examples NPN Open Collector Output Proximity Sensor - Input logic: Negative logic (No-voltage input) (neg) Recommended proximity sensor: APS--N/E Brown Power Source for Sensor ( V DC)* Voltage Output or PNP Open Collector Output Proximity Sensor - Input logic: Positive logic (Voltage input) (pos) Recommended proximity sensor: APS--E Brown Power Source for Sensor ( V DC)* For Measurement Black IN For Measurement Black IN For Reset Black Reset For Reset Black Reset Blue 0 V Blue 0 V -wire DC System Proximity Sensor - Input logic: Negative logic (No-voltage input) (neg) Recommended proximity sensor: APS--Z * In the case of the DC power source type, the supply voltage should be not less than 0 V. Rotary Encoder - Input logic: Positive logic and negative logic are set in accordance with the output of the encoder. Recommended rotary encoder: TRD-J-S, TRD-N-S For Measurement White IN Red (Brown) Green (Black) IN Power Source for Sensor ( V DC)* For Reset White Reset Black 0 V Black (Blue) 0 V Switch Relay - Input logic: Negative logic (No-voltage input) (neg) - Measurement input response: 0 Hz (DIP switch is.) - Input logic: Positive logic (Voltage input) (pos) - Measurement input response: 0 Hz (DIP switch is.) TC-V Measurement Reset IN Measurement Reset Power Source for Sensor ( V DC)* IN Reset Reset TC- 0 V 0 V * There is no power source for sensors in the case of the DC power source type. Use a separate external power source. Output Connection Examples NPN Open Collector Output Contact Output Relay Drive Possible OUT 0V Load + Power Source for Load Rated V DC COM N.C. 9 N.O. 0 Load Load Power Source for Load KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

61 / Controller TC-V Series Each Part Name and Function Panel Explanation Output display (Red) - Operation mode Lights up when the output is. Blinks when the prediction output is. Protection display (Red) - Operation mode Blinks when the key is protected. (Only when the key is ) - Setup mode Displays the set contents of key protection. RST key - Operation mode Turns output off. - Setup mode Selects the setting item. Equipped with -stage Preset * Compared with panels equipped with a -stage preset, models dedicated to display have the following different points. Output display : None Protection display : None Preset value display : No display in the operation mode. Digit key : Ineffective in the operation mode. RST key : Ineffective in the operation mode. Discrete value display (Red) - Operation mode Displays the discrete value. - Setup mode Displays the set contents. Preset value display (Green) - Operation mode Displays the preset value. - Setup mode Displays the setting item. Digit key - Operation mode Changes the preset value. - Setup mode Selects the set contents. INFORMATI Key Operation. Changes the preset value Every time a digit key is pressed, is added to the preset value of the corresponding digit. Approx. second after a digit key is released, the set value is entered.. Turns output off* Only for models equipped with single preset If the [RST] key is pressed (response time is 0.s), output turns. If the [RST] key is pressed while output is, output turns. Example: When the counter is Press the key and the Press the key and the Press the key and the TC-V TC-. Key protection* Only for models equipped with single preset The key protection can be individually set for each operation key. If a key for which the key protection is set is pressed in the run mode, the LED corresponding to the pressed key blinks to notify that the operation is prohibited. Since the protection is set to all keys before shipment, if the power is supplied when DIP switch is, operation of all keys is prohibited. RST The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

62 / Controller TC-V Series Each Part Name and Function DIP Switch Setting - Use the DIP switches at the top of tachometer for setting. - Before operating the DIP switches, be sure that the power is turned off. The switches do not respond to setting changes while the power is on. Input Frequency Select the input frequency with the DIP switch. Input Frequency SW INFORMATI Dip Switch 0 Hz 0 khz Measuring Time Select the measuring time with the DIP switches and. - In the period measurement mode, the display may fluctuate when the device rotates at high speed because the display is updated every time the pulse is input. - If the measuring time is set, the average pulse input during the measuring time can be displayed and the display becomes stable when the device rotates at high speed. Measuring Time SW SW * The DIP switches are all set in the position before shipment. 0. s 0. s.0 s.0 s Selects the operation mode. Selects the key protection. Selects the stop judgment time. Stop Judgment Time Select the stop judgment time with the DIP switches,, and. - After the measurement input turns and the stop judgment time elapses, this function makes the display "0." - Note that, if the stop judgment time is set to 0. s in P/R, the minimum number of revolutions becomes 00 rpm. Selects the measuring time. Stop Judgment Time SW SW SW Selects the input frequency..0 s (0).0 s (0).0 s (0) 0. s (0) 0. s (00) The parenthesis represents the minimum number of revolutions in the case of P/R. TC-V TC- Key Protection Select whether "not to use key protection" or "to use key protection" for the keys set in the setup mode with DIP switch. The keys for key protection can be set in the setup mode. "Not to use key protection" is set before shipment. This is for setting protection * The models dedicated to display should remain. Key Protection SW Setup mode setting is enabled. Do Not Operation Mode Select the setup mode and the operation mode with DIP switch. Operation Mode SW Setup mode Operation mode KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

63 / Controller Setup Mode Make settings that cannot be selected with the DIP switches, in the setup mode. Setup Mode Setting Items () Prescaling Set the prescale value (0-9 to 999,999). () Input logic Positive logic, Negative logic () Output mode Comparison / Holding () Decimal point Set the decimal marker to any digit. () Prediction output Set the offset value for the preset value. 0 to 999,999 () Reset key protection Set the lock for the reset key. () Digit key protection Set the lock for the digit keys. * For tachometers dedicated to display, items (), (), (), and () are skipped. To the next menu by pressing the reset key RST RST RST TC-V Series Each Part Name and Function Prescale setting (scl) Discrete value display part Digit key to 999,999 can be set. Prescale setting (scl) : The exponent is -. 0 to -9 can be set. Input logic setting (si g) : pos Positive logic : neg Negative logic Initial value: Initial value: 0 Initial value: INFORMATI Switching Between the Setup Mode and the Operation Mode RST Output mode setting (c-op) : Select the holding output : Select the comparative output Initial value: Operation Mode Setup Mode When DIP switch is in the position and the power is turned on, the setup mode starts. When the DIP switch is in the position and the power is turned on, the operation mode starts. RST Decimal point setting (d. p) Initial value: No decimal point The decimal point appears after the digit number corresponding to the digit key number. Digit key is used for the setting for no decimal point. Discrete value display part Digit key Operation of the Setup Mode Initialize the setup mode using the menu as shown in the table on the right. (Use the digit keys for all settings.) RST Prediction output setting (set ) a Initial value: 0 Discrete value display part Digit key - For tachometers dedicated to display, the setting items with an * mark are skipped. - The set contents become effective when moving to the next menu via the [RST] key. - The key protection setting becomes active in AND conditions with the DIP switch. If you want to activate the protection, set DIP switch in the position. RST Reset key protection setting (rpro) Initial value: Locked Select whether to lock the reset key or not. Digit key: K/P display part : (Lock) : (Unlock) Digit key protection setting (ppro) Initial value: Locked Digit key K/P display part : Not use : Lit when disabled : Use : Enabled when out To the first menu by pressing the reset key RST Select the whether to lock each digit key or not. Digit key: K/P display part : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) TC-V TC- The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

64 / Controller INFORMATI TC-V Series Example of Operation Operation Mode Changes the Preset Value Change the preset value from 0 to 0. The preset value becomes effective approx. second after the change is made. Before Changing OUT K/P RST OUT K/P RST Press the digit key Example of Setting the Rotating Speed Display Displays the rotating speed when the rotary encoder of 00 pulses per revolution is used. Sets the measuring time to.0 s to stabilize the display when the encoder rotates at high speed. Moreover, displays the stop judgment time for.0 s to decimal place. OUT K/P TC-V METER RST Setting item Measuring Time Setting Item Stop Judgment Time Measurement Axis OUT K/P RST Change Complete OUT K/P RST twice. Press the digit key Once. Rotary Encoder 00 P/R Contents Prescale Mantissa.0 s.0 s Prescale Exponent -. Change the set contents To the next menu by pressing the reset key RST RST RST RST Press the reset key to end setup. RST Prescale Mantissa Setting screen Change to the initial value. Prescale Exponent Setting screen Press the to "-." key twice to set it Setting Input Logic screen Change to the initial value. Output Mode Setting screen Change to the initial value. Decimal Point Setting screen Press the key to light up the decimal point between st digit and nd digit. This setting is complete.. Switching to the operation mode When setup is completed in the setup mode, turn the power off, set DIP switch in the position (to the operation mode) and turn the power.. Start the operation mode When a setting is changed in the setup mode, be sure to press the [RST] key to reset the count value after the power is turned on. TC-V TC-. Prescale calculation The tachometer has the prescale "" at pulse per revolution. Therefore, in the case of 00 P/R, 00 = 0.0 Since the prescale setting is set by the mantissa and exponent, 0.0 = 0 -. Setting DIP switches Turn the power off before operating the DIP switches. Selecting the.0 s measuring time - Set DIP switch is in the position. - Set DIP switch is in the position. Selecting the.0 s stop judgment time - Set DIP switch is in the position. - Set DIP switch is in the position. - Set DIP switch is in the position.. Switching to the setup mode Set DIP switch in the position, and turn the power on. 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

65 / Controller Common Errors Error Code Error Name Error details Corrective Action TC-V Series Error Code Display/Option Overflow error Underflow error The data that should be displayed is larger than the display range. The digit of the data that should be displayed is lower than the display range. The error indication will be automatically reset when the measured value enters the normal range. (Review the prescale and decimal point setting.) INFORMATI Over input frequency Input frequency exceeds 0 khz. Lower the input frequency. Memory data error Preset value / Set value and the contents of the setup mode changed. Press the [RST] key and delete the error indication. The measured value and the timing value become "0", the preset value and the set value become ",000", and the contents of the setup mode revert back to the preshipment defaults. Option Rubber Packing Option Model Number Contents Price KC-P If installed between the installation panel and TC-V, it prevents the intrusion of water into the control panel. Open Front Cover KC-C If installed to the front panel, it protects the counter from exposure to dirt, etc. Material: Soft silicon rubber Key operation is enabled with the front cover installed. Open TC-V TC- The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

66 / Controller INFORMATI TC-V Series Precautions Precautions in Use () The power source 0 V terminal and the input common 0 V terminal of the DC type are internally short-circuited. () Rather than gradually increasing the supply voltage, apply the rated voltage at once using a switch or relay. () When using the -wire DC system proximity sensor, set the input logic to negative logic. () If the preset value / set value is changed during measurement / timing, the changed value becomes effective approx. second after key input. (The tachometer performs output operation after measurement.) () Enter the set contents of the DIP switches and the setup mode in the data sheet attached to the main body and keep it for maintenance. () Do not use the counter in the following environments. - Any place where the ambient temperature exceeds 0 C or falls to -0 C or lower. - Any place where the ambient humidity exceeds % or condensation occurs due to rapid temperature change. - Any place that is exposed to dust, iron powder, and corrosive gas. - Any place that is exposed to sunlight. - Any place where there are large vibrations or shocks. () When performing a dielectric voltage test or insulation resistance test, separate the main body from the control circuit. () When the power is shut down, the internal EEPROM is written. Since the number of writing cycles in the EEPROM is not more than 00,000, do not use the tachometer by highly frequent power source operations. Cautions in wiring - Wire cables separately from power lines. - When using the counter in a place where a lot of noise is generated, separate the main body of the TC-V and the wiring from the noise sources as far as possible. - Do not use an unused terminal as a relay terminal. - It is recommended to use a crimp terminal for connections. - When wiring the cable to the terminals and, if the crimp terminal has a fork shape, do not attach it diagonally. For diagonal attachment, use a round crimp terminal. In the Case of a Forked Crimp Terminal If the crimp terminal is diagonally attached, the contact with the terminal becomes insufficient. Therefore, attach the crimp terminal horizontally from the side as shown in the figure above. In the Case of a Round Crimp Terminal Insert the main body into the attachment bore of the panel. How to Mount and Remove the Main Body How to mount the main body Insert the main body into the attachment bore of the panel. Insert the main body into the attachment bore of the panel. - As the screw for anchoring the terminal block, only use the anchoring screw used in shipping. How to mount - Make the terminal sure that the block allowable and tightening the terminal torque is 0. Nm. block cover - Mount the terminal block cover after the wiring is completed. - As the screw for anchoring the terminal block, - As the screw for anchoring the terminal block, only use the anchoring screw used in shipping. only use the anchoring screw used in shipping. - Make sure that the allowable tightening torque is 0. Nm. - Make sure that the allowable tightening torque is 0. Nm. - Mount the terminal block cover after the wiring is completed. - Mount the terminal block cover after the wiring is completed. TC-V Attach the mounting frame from the backside. TC- Body Attach the mounting frame from the backside. Attach the mounting frame from the backside. Body Body Terminal Block Fixing Screw Mounting Frame: The frame can be mounted both in the longitudinal and transverse directions. Mounting Frame: Mounting Frame: The frame can be mounted both in the longitudinal The frame can be and mounted transverse both directions. in the longitudinal and transverse directions. How to remove the main body Pinch the levers to spread them to mm outwards. Pull out the frame while the levers are spread. Terminal Block Terminal Block Cover Terminal Block Fixing Screw Fixing Screw Terminal Block Cover Terminal Block Cover Pinch the levers to spread them to mm outwards. Pinch the levers Pull to spread out the them frame while to mm the outwards. levers are spread. Pull out the frame while the levers are spread. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

67 / Controller TC-V Series Dimensions Dimensions (Unit: mm) Main Body of the TC-V Mounting Frame 0 (DC Power) 00 (AC Power) INFORMATI. to : Mounting Panel Thickness 0 0 DC Power AC Power Overall Depth mm 0 mm Terminal Block Detail Drawing Panel-cut Dimensions for Embedded Installation Terminal Screw M.= When the mounting handle direction is in the transverse direction Mounting Frame 0 or more. When the mounting handle direction is in the longitudinal direction (Tight Mounting is Possible) 9.. or more Square Hole or more Conforming cable size : 0. to. mm Conforming crimp terminal : R.- Allowable tightening torque : 0. Nm TC-V TC- The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

68 / Controller TC- Series s Common Features INFORMATI Digital - Prescale functions (Except TC-L) The TC- series features built-in prescale functions that can convert the number of revolutions into speed, flow rate, and the amount of production per unit time. - High accuracy Owing to the period measurement method, the TC- series offers high measurement accuracy in low speed rotation. The sampling function guarantees sufficient accuracy even in high speed rotation. - Immediate zero display when rotation stops (TC-) The display becomes zero or seconds after rotation stops. TC- Series s Lineup Classification Appearance Model Number Digit Input Power Source Power Source for Sensors Price Models Dedicated to Display TC- Open collector 90 to V AC 0 to V AC V DC, 0 ma Open Digital Output TC-B Open collector 90 to V AC 0 to V AC V DC, 0 ma Open Models Dedicated to Display TC- Voltage, current and electromagnetic detector 90 to V AC 0 to V AC V DC, 0 ma Open Models Dedicated to Display TC-L-G Open collector to V AC V DC, 0 ma Open TC-V Models Dedicated to Display TC-L-H Open collector 0 to 0 V AC V DC, 0 ma Open TC- KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

69 / Controller Measurement Examples Examples of Measurement in Each Mode ( Modes) TC- Series s Common Specifications Number of revolutions Mode Speed Mode TC- series all support Passage speed Mode TC-, B support INA INA INA INA INA INA INA INA INA rpm rpm rpm Detector rpm rpm Detector Detector m/min. Detector Detector m/min. m/min. m/min. m/min. Motor Motor Motor Motor Motor INB INA m INB INB INA INA m/min. m m/min. m/min. INB INA m INB INA m/min. m m/min. Number of Revolutions Number Number of of Revolutions Revolutions Speed Number of Revolutions Number of Revolutions Speed Speed Speed Speed Mode displays the number of revolutions. If the signal of the rotating detector is applied, the number of revolutions (rpm) is displayed. If the prescale is performed in mode, mode displays the speed. The number of revolutions x r = speed (r = radius of roller: m) If the interval of the detector is not m or if you want to make the mode to the speed-per-second display, the prescale should be used. INFORMATI Period Mode TC-, B support Time difference Mode TC-, B support Operating time Mode TC-, B support Length measurement Mode TC-, B support Interval Mode TC-, B support Prescale counter Mode TC-, B support INB INB INB INB INB Length Sec. Sec. Sec. INA Sec. INA INA Sec. INA Sec. INA Sec. INA Sec. INA Sec. Sec. Passage Speed Period Passage Passage Speed Speed Period Period Rotary Passage Speed Period Encoder Passage Speed Period Rotary Parts FeederRotary Encoder Encoder Parts Parts Feeder Feeder Rotary Encoder Rotary Parts FeederEncoder Parts Feeder The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. INA INA Sec. INA INA Sec. Sec. INA INA Sec. Sec. Length cm Length cm cm Length INA Length INB cm INA INA cm INB INB INA INB INA INB Interval Interval cm Interval cm cm Interval INA INB Interval cm INA INA INB INB cm INA INA Integrating Integrating Integrating INA INA INB INB Integrating INA Integrating INA INA INA INA A A A A Interval Interval Interval Interval Interval Proximity Sensor Proximity Proximity Sensor Sensor Proximity Sensor Proximity Sensor Press Press Press B B B B Press Object Being Pressed Press Object Object Being Being Pressed Pressed Object Being Pressed Object Being Pressed Length Length Length Length Length Rotary Encoder Rotary Rotary Encoder Encoder Rotary Encoder Rotary Encoder Rotary Encoder Rotary Rotary Encoder Encoder Rotary Encoder Rotary Encoder The repetition period and passage time can be measured. Period measurement: 0 ms to 0 s Passage time: Unlimited The time when the operation is performed, such as the pressing time of a pressing machine, or the time when the bulb is open, is displayed. Measurement range: 0 ms to 0 s The time when the operation is performed, such as the pressing time of a pressing machine, or the time when the bulb is open, is displayed. Measurement range: 0 ms to 0 s The pulse of the rotary encoder while the photoelectronic sensor for detecting objects is turned on is counted, and displayed as the length of the object after the passage of the object. A rotary encoder of any pulse number can be used via the prescale functions. The pitch (interval) of the processing hole is measured and displayed. A rotary encoder of any pulse number can be used via the prescale functions. The input pulse is counted and the accumulated value is displayed. For the functions with preset, the device operates as a preset counter. Using the prescale functions, a discrete value multiplied by any number can be displayed and preset. KOYO ELECTRICS INDUSTRIES CO., LTD. TC-V TC-

70 / Controller TC- Series s Common Specifications INFORMATI Description of Functions Prescale Functions In this function, the measured data is multiplied by a -digit numeric value set in advance, and the results of calculation are displayed or output to the display and the output terminal. The multiplication value is set by the five miniature rotary switches on the back of case. The numeric value that can be set is expressed in M x 0 -n where M represents a -digit integer and n represents any numeric value from 0 to 9. The maximum numeric value that can be set becomes 9,999 in the case of M = 9,999 and n = 0, and the minimum numeric value becomes x 0-9 in the case of M = 000 and n = 9. The TC -L does not have this function. Dip Switch Sampling Function (Effective only for mode ) The measurement principle of TC series tachometers is the period measurement method in which the time required for the measured axle to rotate one revolution is measured and the revolutions per minute are calculated based on the time. In this method, if the axle rotates at high speed, the time required for one revolution becomes shorter, deteriorating the measurement accuracy. Therefore, in the TC series, other than the regular period measurement for every one revolution, the number of revolutions is calculated from the time required for 0 revolutions or 00 revolutions in order to prevent the deterioration of measurement accuracy in high speed rotation. This is called the "sampling function" and the number of samplings can be set from the DIP switch (miniature switch) to either, 0, or 00 revolutions (only time for the TC-L). - Sampling Frequency is Set to. Set in Units of Period - Sampling Frequency is Set to X0 -n X,000 X00 X0 X M Rotary Switch Set in 0 Units of Period Sampling Frequency is Set to Example of prescale value, Decimal Point Switching Function It is possible to make the decimal point light up in any position of a -digit numerical value on the display. Since the correct data is always displayed according to the position of the decimal point, the placement of the decimal point is not necessary. The decimal point lighting position can be set from the DIP switches on the back of the case. Set in 00 Units of Period Error Code Display Function The error code is displayed when the measurement data exceeds the effective range or the prescale value is set outside the prescribed range. TC-V TC- No decimal point decimal place decimal place decimal place Common Errors Error Code Error Name Error details Overflow error The data that should be displayed is larger than the display range. Underflow error The digit of the data that should be displayed by prescale and decimal point setting is lower than the display range. Prescale setting error The integer part setting of the prescale set value is zero. Over input frequency The input frequency in the mode exceeds 0 khz. (Note) The error indications of E0, E0, and E0 will automatically reset when the measured value enters the normal range. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

71 / Controller TC- Series s Common Specifications Explanation of the Run Mode Mode : Measurement of the Number of Revolutions (rpm) * Excluding the TC- (See individual specifications). * The TC-L does not have IN B. - The reciprocal (/T) of the input period (T) of IN A is multiplied by 0 and displayed as the number of revolutions (rpm). - IN B is prohibited from input and the internal measurement operation is prohibited when IN B is and the display data continues holding the previous state. Display IN A IN B Previous measurement T 0 rpm T T 0 rpm 0 rpm Retains 0 rpm T T T The measuring range is 0 to 9,999 rpm when the input is P/R, sampling =, and prescale =. In the case above, the period (T) should be 00 ms or more, and if the period is below 00 ms, the number of revolutions is measured at the interval of one period of more. The previous measured value is displayed sec after rotation stops. Mode : Measurement of Passage Speed (m/minute) - The reciprocal of the time (T) from of IN A to of IN B is multiplied by 0 and displayed as the passage speed between point A and point B. - When the interval of the sensor for IN A and the sensor for IN B is m, the units are m/min. Display IN A IN B Previous measurement T T 0 m/min T Ta T Ta T 0 m/min 0 m/min T T The measuring range T should be between 0 ms and sec. Until the start of the next measurements, downtime Ta of 0 ms is required. Mode : Operating Time (Measuring Range: 0 ms to 0 s) - The time (T) when IN A is is measured and displayed. The time that can be measured is from 0 ms to 0 s. - IN B is prohibited from input and the internal measurement operation is prohibited when IN B is and the display data continues holding the previous state. - If IN B turns during measurement, the measurement operation is canceled. Display IN A T IN B Downtime Ta0 ms Mode Mode : Length Measurement (Measurement of Length)* IN A responsivity: 0 khz - The number of pulses that are input to IN A while IN B is is counted, and the number of pulses counted when IN B is is displayed. - When the reset input is, the indicated value returns zero. Display IN A IN B Reset Previous measurement T T T Ta T T Previous Count Discrete Value Discrete Value Zero 9 0 T Counting at This Interval Ta Counting at This Interval T ms Ta0 ms INFORMATI Mode : Period (Measuring Range: 0 ms to 0 s) - The input period of IN A is measured and displayed as is. However, the period that can be measured is from 0 ms to 0 s, and measurement is performed every two periods. - IN B is prohibited from input and the internal measurement operation is prohibited when IN B is and the display data continues holding the previous state. If IN B turns during measurement, the measurement operation is canceled. Display Previous Measurement T T T Retains T T IN A T Ta T Ta T T IN B Until the start of the next measurements, downtime Ta of 0 ms is required. Mode : Time Difference (Measuring Range: 0 ms to 0 s) - The time (T) from of IN A to of IN B is measured and displayed as is. The time that can be measured is from 0 ms to 0 s. Display Previous measurement T T Mode Mode : Interval (Measurement of Interval) * IN A responsivity: 0 khz - The number of pulses that have been input in IN A since IN B turned is counted, and the number of impulses that have been input in IN A until IN B turns next is displayed. - When the reset input is, the indicated value returns zero. Display IN A IN B Reset Previous Count Discrete Value Discrete Value 9 Zero Display Counting at This Interval (0 ms or more) Counting at This Interval (0 ms or more) Mode Mode : Prescale (Integrating Display of Pulse) * IN A responsivity: khz - The number of pulses applied to IN A is counted and a discrete value is displayed. - IN B is the prohibition input for IN A and ignores the input of IN A while IN B is. - When the reset input is, the indicated value returns zero. TC-V TC- IN A T IN B Downtime Ta0 ms Ta T Display IN A IN B Input Inhibit Reset The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

72 / Controller TC- Series s Use Example INFORMATI Example of Connection of the Terminal Proximity Sensor The type of proximity sensors that can be connected are the APS series models with an N or E and Z attached to the output symbol. Example: APS-F-E For IN A Proximity Sensor For IN B Proximity Sensor Rotary encoder + V Brown (Red) OUT Black (White) 0 V Blue (Black) + V Brown (Red) OUT Black (White) 0 V Blue (Black) + V IN A IN B R 0 V Reset + V IN A IN B R 0 V 9 00 V AC 0 00 V AC Example Applications Example : Measurement of the Travel Speed Between the Two Points As shown in the figure below, the travel speed of an object that passes below the sensors installed at the interval of meter is detected and displayed as the travel speed per minute (m/minute). TC- IN B IN A m/min. Design Selection of a model Display the TC- for the speed indication. Design Input sensor Use the photoelectronic sensor for IN A and IN B. m Sensor + V OUT 0 V TRD-J-S TRD-J-RZ Red Green Black Shield Design Setting DIP switches Set the DIP switches on the back of the TC-. Switch Purpose Design Condition Setting Input frequency high speed input Decimal point digit after decimal point (000.0) Operation mode Mode Number of samplings Design Setting the prescale Set to x. (The prescale is set to x before shipment.) X0 -n X000 X00 X0 X TC-V TC- Design Connection 9 0 +V IN A IN B R 0V 00V AC Photoelectric Sensor For IN A Photoelectric Sensor For IN B Reset (Reset the display.) KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

73 / Controller TC- Series s INFORMATI TC-V TC- The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

74 / Controller INFORMATI TC- Features Display-dedicated Type - Multifunctional high-performance model for display - The large LED numeric indicators that emit red light display bright, easy-tosee characters with the height of. mm. - The operation modes enable measurement of the number of revolutions, speed, period, time difference, duration, length and interval, and integration. - The TC- has a prescale, sampling, and decimal point switching functions. - Display period: When the period of the input pulse is within 0. sec, the displayed data changes every 0. sec. TC-V TC- Electrical Specifications Items Rated Voltage Range Rated Frequency Power Consumption Withstand Voltage Insulation Resistance Specifications 90 to V AC/0 to V 0/0 Hz VA,000 V AC min (Between power supply and external terminal) 0 MΩ or higher 00 V DC (Between power supply and external terminal) Environmental Specifications Items Ambient Operating Temperature Storage Temperature Use / Storage Ambient Humidity Vibration Resistance Impact Resistance Noise Resistance -0 to +0 C - to +0 C (No freezing) Specifications to 90% RH (No condensation) Input Specifications Name Endurance: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Malfunction: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Endurance: 90 m/s ms, axial directions Malfunction: 9 m/s ms, axial directions kv μsbetween power supply terminals Responsivity Input Resistance Specifications Voltage Input Voltage Voltage Function/Performance Specifications Items Counting System Function Display Basic Measurement Range Period measurement system Only display Specifications Red -segment LED, -digit, height of characters. mm 0 to 9,999 rpm, 0 ms to 0 s, to 9,999 count Measurement Accuracy degit (mode )/0. ms (mode to ) Measurement Item Prescale Functions mode* M x 0 -n 0-9 to 9,999 M 9,999, 0 n 9 (M and n are integers) Sampling Function time, 0 times, 00 times (Effective only for mode ) Connection Method Power Source for Sensors Power Source Reset Dimensions (mm) Weight Accessories Price Backside screw terminal block V DC0 ma Power supply shutdown time 0. s/reset time 0. s 9 W x H x 0 D Approx. 0 g Mounting brackets, unit label Open * mode Mode Number of revolutions rpm Mode Passage speed m/minute Mode Period Second Mode Time difference Second Mode Operating time Second Mode Length measurement Mode Interval Mode Prescale counter Count Input Reset Input* 0 Hz 0 khz Switching kω 0 to V 0 to 0 V 0 ms * The display cannot be reset in modes to. Input Single Pulse Width INAINB Low Speed H L 0 ms or more 0 ms or more INAINB High Speed H L 0 µs or higher 0 µs or higher Configuration of the Input Circuit INAINBReset + V Input Single Each Input kω Up to ma 0 V Internal Circuit When each input terminal is short-circuited to the 0 V terminal, input turns. 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

75 / Controller Explanation of the Back Panel The connecting terminals and setting switches are centrally provided on the back panel of the case. DIP Switches Rotary Switch TC- Each Part Name and Function Setting the Back Side DIP Switches Back Switching the Number of Samplings ( time, 0 times, 00 times) INFORMATI Prescaling Operation Mode Switching ( Modes) Decimal Point Switching 9 0 Input Frequency Switching Terminal Block Switch Input Frequency Switching Setting the Prescale The prescale function is used for displaying the obtained measured value multiplied by a certain constant. The Rotary Switch Turned with a Screwdriver /Position 0 Hz for both IN A and IN B (Low speed) /Position 0 khz for both IN A and IN B (High speed) Switch Decimal Point Switching X0 -n X000 X00 X0 X Measured Value x Prescale Value = Indicated Value As the prescale value, any -digit numeric value from a minimum x 0-9 to a maximum 9,999 x 0-0 = 9,999 can be set. [Note] - The exponent (0 -n ) can be set in the range of 0 to 9. - If the prescale function is not used, the prescale should be set to x 0-0 = as shown below. Switch Switch Operation Mode Switching Switch Mode Mode Mode Mode Mode Mode Mode Mode TC-V TC- Switch Switching the Number of Samplings Switch Time 0 Times 00 Times The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

76 / Controller TC- Connection Connecting the Terminal Block 9 0 INFORMATI + V IN A IN B R 0 V 00 V AC 00 V AC Terminal Number Symbol Description + V DC power output for supplying to the sensor IN A Input IN B Input R Reset input (Display is reset in modes,, and.) 0 V Common of input and sensor power supply Empty (Not connected) Empty (Not connected) Empty (Not connected) 9 00 V AC 0 00 V AC 0 V AC Power source input TC-V TC- KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

77 / Controller TC- Dimensions Dimensions (Unit: mm) to : Mounting Panel Thickness Anchoring Metal (Provided) INFORMATI 9 99 Panel-cut Dimensions for Embedded Installation Terminal Block Detail Drawing If the dust cover (provided) is used, the dimensions should be x 9. TC-V TC- The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

78 / Controller INFORMATI TC-B Features Display-dedicated Type with Digital Output - Having the basic configuration of the TC-, the TC-B model features additional digital output (BCD code) functions. - Other functions except the digital output are the same as the TC-. - Display period: Although the display data and BCD output are the same, the digital output is output earlier than the display data when the input period is not longer than 0. sec. TC-V TC- Electrical Specifications Items Rated Voltage Range Rated Frequency Power Consumption Withstand Voltage Insulation Resistance Specifications 90 to V AC/0 to V 0/0 Hz VA,000 V AC min (Between power supply and external terminal) 0 MΩ or higher 00 V DC (Between power supply and external terminal) Environmental Specifications Items Ambient Operating Temperature Storage Temperature Use / Storage Ambient Humidity Vibration Resistance Impact Resistance Noise Resistance -0 to +0 C Input Single Pulse Width INAINB Low Speed H L 0 ms or more 0 ms or more INAINB High Speed H L 0 µs or higher 0 µs or higher - to +0 C (No freezing) Specifications to 90%RH (No condensation) Input Specifications Name Count Input Reset Input Hold Input Endurance: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Malfunction: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Endurance: 90 m/s ms, axial directions Malfunction: 9 m/s ms, axial directions kvμsbetween power supply terminals Responsivity 0 Hz 0 khz Switching 0 ms Specifications Input Input Voltage Resistance Voltage Voltage Configuration of the Input Circuit INAINBResetHold + V Input Single kω 0 to V 0 to 0 V Each Input kω Up to ma 0 V Internal Circuit When each input terminal is short-circuited to the 0 V terminal, input turns. Function/Performance Specifications Items Counting System Function Display Basic Measurement Range Specifications Period measurement system Digital output (BCD output -digit) Red -segment LED, -digit, height of characters. mm 0 to 9,999 rpm, 0 ms to 0 s, to 9,999 count Measurement Accuracy degit (mode )/0. ms (mode to ) Measurement Item mode* Prescale Functions M x 0 -n 0-9 to 9,999 M 9,999, 0 n 9 (M and n are integers) Sampling Function time, 0 times, 00 times (Effective only for mode ) Connection Method Backside screw terminal block Power Source for Sensors V DC0 ma Power Source Reset Power supply shutdown time 0. second/ Reset time 0. second Dimensions (mm) 9 W x H x 0 D Weight Approx. 0 g Accessories Mounting brackets, card edge connector, unit label Price Open * mode Mode Number of revolutions rpm Mode Passage speed m/minute Mode Period Second Mode Time difference Second Mode Operating time Second Mode Length measurement Mode Interval Mode Prescale counter Output Specifications Circuit Configuration Open collector Operation for data Working Voltage V or lower Working Current 0 ma or lower Residual Voltage V or lower BCD Output and BUSY/ HOLD Timing (Example of Mode ) IN A Internal Operation BCD Output BUSY Output HOLD Input 0 ms or less to ms Configuration of BCD Output and BUSY Output,,, ma, Withstand Voltage: Up to 0 V KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. () Visit our website

79 / Controller Explanation of the Back Panel The connecting terminals and setting switches are centrally provided on the back panel of the case. Printed Board (Card Edge Terminals) TC-B Each Part Name and Function Setting the Back Side DIP Switches Back Dip Switch Rotary Switch Switching the Number of Samplings ( time, 0 times, 00 times) Operation Mode Switching ( Modes) INFORMATI Prescaling 9 0 Setting the Prescale The prescale function is used for displaying the obtained measured value multiplied by a certain constant. The Rotary Switch Turned with a Screwdriver Terminal Block Decimal Point Switching Input Frequency Switching Switch Input Frequency Switching /Position 0 Hz for both IN A and IN B (Low speed) /Position 0 khz for both IN A and IN B (High speed) Switch Decimal Point Switching 9 9 X0 -n X000 X00 X0 X Measured Value x Prescale Value = Indicated Value As the prescale value, any -digit numeric value from a minimum x 0-9 to a maximum 9,999 x 0-0 = 9,999 can be set. [Note] - The exponent (0 -n ) can be set in the range of 0 to 9. - If the prescale function is not used, the prescale should be set to x 0-0 = as shown below. Switch Switch Operation Mode Switching Switch Mode Mode Mode Mode Mode Mode Mode Mode TC-V TC- Switch Switching the Number of Samplings Switch Time 0 Times 00 Times The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

80 / Controller INFORMATI TC-B Connection Connecting the Terminal Block V IN A IN B R 0 V Terminal Number Symbol Description 00 V AC 00 V AC + V DC power output for supplying to the sensor IN A Input IN B Input R Reset input (Display is reset in modes,, and.) 0 V Common of input and sensor power supply Empty (Not connected) Empty (Not connected) Empty (Not connected) 9 00 V AC 0 00 V AC 0 V AC Power source input Example of BCD Output Connection If No. (input common) of the card edge terminal is connected to No. (CH), the input common is separated from the output common. When taking in BCD data from two or more TC-B units for the PLC (programmable controller), the TC-B units can have a common BCD output and BUSY output, and, therefore, the PLC can configure input points. In this case, however, all BCD outputs and BUSY outputs require a diode. TC-B 0 V CH TC-B 0 V CH digit digit BUSY OC digit digit BUSY OC A B D A B D PLC (Example: SU-B) Input BCD Input BUSY Input Selection Selection Output Connection of a Card Edge Terminal The TC-B outputs -digit decimal numbers by BCD signal to the card edge terminal (connector is provided). 9 0 Symbol of the Terminal Nameplate B A 9 0 A B A C D C B A B D C D A B BUSY HOLD 0 V C D BUSY HOLD 0 V OC CH OC CH Meaning of the Signal Upper B Bottom A Digit and Others BUSY HOLD BUSY HOLD 0 V 0 V OC OC CH CH Empty Empty digit digit digit digit OUT OC Output Input Common Common Switching TC-V TC- Note: Card edge terminal No. and terminal No. of the terminal block are internally connected. Switching the OUT Common Terminal No. and terminal No. are internally connected. If the No. CH and terminal No. are short-circuited, terminal No. is separated to the input common and terminal No. is separated to the output common respectively. 0 V OUT Common CH Input Common Output Common KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

81 / Controller TC-B Dimensions Dimensions (Unit: mm) to : Mounting Panel Thickness Multi-connector (Provided) INFORMATI Anchoring Metal (Provided) 9 (9.) 99 0 Panel-cut Dimensions for Embedded Installation Terminal Block Detail Drawing TC-V TC- The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

82 / Controller INFORMATI TC- Features Display-dedicated Type with Multifunctional Input - Models dedicated to displaying the number of revolutions feature an input circuit that can support all kinds of devices. - The TC- quickly displays zero when rotation stops ( or sec after rotation stops). To display the measured value for sec as an average, the TC- can minimize the instability of the display caused by the rotating irregularity of the measured machine. - The TC- features prescale, sampling, and decimal point switching functions. Electrical Specifications Items Rated Voltage Range Rated Frequency Power Consumption Withstand Voltage Insulation Resistance Specifications 90 to V AC/0 to V 0/0 Hz VA,000 V AC min (Between power supply and external terminal) 0 MΩ or higher 00 V DC (Between power supply and external terminal) Environmental Specifications Items Ambient Operating Temperature Storage Temperature Use / Storage Ambient Humidity Vibration Resistance Impact Resistance Noise Resistance -0 to +0 C - to +0 C (No freezing) Specifications to 90%RH (No condensation) Endurance: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Malfunction: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Endurance: 90 m/s ms, axial directions Malfunction: 9 m/s ms, axial directions kv μs Between power supply terminals Function/Performance Specifications Items Counting System Function Display Basic Measurement Range Measurement Accuracy Period measurement system Specifications Only display, Multifunctional input Red -segment LED, -digit, height of characters. mm 0 to 9,999 rpm/0 to 9,999 rpm Switching degit Measurement Item Number of revolutions (rpm) (Only for mode ) Prescale Functions M x 0 -n 0-9 to 9,999 M 9,999, 0 n 9 (M and n are integers) Sampling Function time, 0 times, 00 times (Effective only for mode ) Connection Method Power Source for Sensors Power Source Reset Dimensions (mm) Weight Accessories Price Backside screw terminal block V DC0 ma Power supply shutdown time 0. s/reset time 0. s 9 W x H x 0 D Approx. 0 g Mounting brackets, unit label Open * Since the mean value for sec is displayed, if the measured value has changed, the intermediate value is displayed. TC-V TC- Input Specifications Name Configuration of the Input Circuit Voltage Input, Voltage Input + V V Responsivity V. k Input Resistance Specifications Voltage Input Voltage Input for Electromagnetic Detector V V k Input Voltage Voltage Voltage Input ( to V) kω 0 to V to 0 V Voltage Input ( V) 0 Hz kω 0 to. V. to 0 V 0 khz Current Input Switching. kω* 0 to V to 0 V Current Input kω* 0 to V to 0 V Input for Electromagnetic Detector 0 Hz* 0 khz Switching 0 kω 0 Hz : 0. Vp-p or more 00 Hz : 0. Vp-p or more khz : Vp-p or more 0 khz : 0 Vp-p or more Reset Input (Open Collector) 0 ms kω* 0 to V 0 to 0 V * Pull-up to V inside * If the input frequency is 0 Hz or more, set the backside DIP switch in the position (0 khz). IN and IN cannot be simultaneously used. IN Input Single Pulse Width ININ Low Speed 0 ms or more ININ High Speed 0 ms or more 0 µs or higher 0 µs or higher Reset Input IN IN k 0 V 0 V IN 0 V 0 k 0 V 0 V R k Sensor Input Circuit Sensor KOYO ELECTRICS INDUSTRIES CO., LTD. Input Circuit Sensor Input Circuit Latest catalog (free) is available online. Visit our website

83 / Controller Explanation of the Back / Side Panel The connecting terminals and setting switches are installed on the back and side of the case. Dip Switch Rotary Switch TC- Each Part Name and Function Setting the Back Side DIP Switches Back Prescaling Switching the Number of Samplings ( time, 0 times, 00 times) Measurement Range Switching INFORMATI Decimal Point Switching 9 0 Input Frequency Switching * and are not in use. Side Terminal Block Switch Input frequency switching 0 Hz for both IN A and IN B (Low speed) 0 khz for both IN A and IN B (High speed) Switch Decimal point switching Dip Switch Setting the Prescale The prescale function is used for displaying the obtained measured value multiplied by a certain constant. The Rotary Switch Turned with a Screwdriver Switch X0 -n X000 X00 X0 X Switch Measurement range switching Measured value x Prescale value = Indicated value As the prescale value, any -digit numeric value from a minimum x 0-9 to a maximum 9,999 x 0-0 = 9,999 can be set. [Note] - The exponent (0 -n ) can be set in the range of 0 to 9. - If the prescale function is not used, the prescale should be set to x 0-0 = as shown below. The default settings are all zero. 0 to 9,999 rpm* 0 is displayed sec after the rotation stops. 0 to 9,999 rpm* 0 is displayed sec after the rotation stops. * revolution pulse and prescale = Switch Switching the number of samplings TC-V TC Setting when the Prescale is Not Used Switch Time 0 Times 00 Times Setting the Side DIP Switches Input Mode Switching of IN Switch Voltage input ( to V) Voltage input ( V) Current input Current input The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

84 / Controller INFORMATI TC- Connection Connecting the Terminal Block V IN A IN B R 0 V Terminal Number Symbol Description 00 V AC 00 V AC + V DC power output for supplying to the sensor IN Input IN Input R Reset input 0 V Common of input and sensor power supply Empty (Not connected) Empty (Not connected) Empty (Not connected) 9 00 V AC 0 00 V AC 0 V AC Power source input Supported Detectors (Example) Voltage output type sensor ( to V) General-purpose inverter ( V)* TTL (Totem-pole output V) -wire DC system proximity sensor output Gear sensor AC tacho generator Voltage input Voltage input IN Switching by the DIP switches W DC input Electromagnetic detector input IN and IN cannot be used simultaneously. IN * When making a digital rotation display of an inverter motor, connect the signal for frequency meter (tachometer) of the inverter to the TC-. However, if this is an analog signal (voltage, current), it cannot be connected to the TC-. Moreover, if a pulse signal is output, set the TC- so that the output circuit and signal level match with each other. Connection Examples Supported Sensor Input Mode Setting the DIP Switch (Side) Connection diagram Voltage Output Type Sensor ( to V) Voltage output type proximity sensor <Example> APS-0A-T APS-0-T Voltage input V V + V IN IN R 0 V Power Supply OUT 0 V Voltage Output Type Sensor ( V) (General-purpose inverter) TTL of totem-pole output, etc. Voltage input V Power Supply + V IN IN R 0 V OUT 0 V TC-V TC- Namur Output Type Proximity Sensor Current input + V IN IN R 0 V Brown Blue Current Output Type Sensor Open collector output -wire DC system proximity sensor, etc. <Example> APS-GMC-Z APS-GK-Z Current input + V IN IN R 0 V + NPN Open Collector Output Type Sensor Connectable either by Namur input or current input. <Example> APS-GK-E/APS-F-E TRD-J-S/RZ Namur input or current input + V IN IN R 0 V Power Supply OUT 0 V [Note] - When a power supply for sensor (+ V) is used, ensure that the consumption current of the sensor is not more than 0 ma. The sensors shown in the <Example> above are all connectible. - When the input for electromagnetic detector (IN) is used, set all DIP switches on the side in the position. <Example> Gear sensor AC tacho generator, etc. + V IN IN R 0 V 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

85 / Controller TC- Dimensions Dimensions (Unit: mm) to : Mounting Panel Thickness Anchoring Metal (Provided) INFORMATI 9 99 Panel-cut Dimensions for Embedded Installation Terminal Block Detail Drawing TC-V TC- The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

86 / Controller INFORMATI TC-L-G/H Features Display-dedicated Type (Economy Model) - The miniature economy type is for displaying the number of revolutions. To widen the measurement range, the input pulse can be switched between the two stages - pulse per revolution and 0 pulses per revolution. TC-L-G: For 00 V AC ( to V AC 0/0 Hz) TC-L-H: For 00 V AC (0 to 0 V AC 0/0 Hz) TC-V TC- Electrical Specifications Items Rated Voltage Range Rated Frequency Power Consumption Withstand Voltage Insulation Resistance TC-L-G: to V AC TC-L-H: 0 to 0 V AC 0/0 Hz VA Specifications,000 V AC min (Between power supply and external terminal) 0 MΩ or higher00 V DC (Between power supply and external terminal) Environmental Specifications Input Specifications Name Items Ambient Operating Temperature Storage Temperature Use / Storage Ambient Humidity Vibration Resistance Impact Resistance Noise Resistance Count input -0 to +0 C - to +0 C (No freezing) Responsivity 0 Hz khz Switching Input Resistance Specifications to 90% RH (No condensation) Endurance: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Malfunction: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Endurance: 90 m/s ms, axial directions Malfunction: 9 m/s ms, axial directions kv μs Between power supply terminals Specifications Voltage Input Voltage Voltage kω 0 to V 0 to 0 V Function/Performance Specifications Items Counting System Function Display Period Display Basic Measurement Range* Measurement Accuracy Period measurement system Only display Specifications Every 0. sec when the input pulse period is within 0. sec. Input period + 0. sec when the input pulse period exceeds 0. sec. The previous measured value is displayed for sec after rotation stops. Red -segment LED, -digit, height of characters mm 0 to 9,999 rpm degit Measurement Item Number of revolutions (rpm) (Only for mode ) Prescale Functions pulse / rotation, 0 pulse / rotation switching* Sampling Function Connection Method Power Source for Sensors Power Source Reset Dimensions (mm) Weight Accessories Price Once Dedicated stand B or stand F socket (Sold separately) V DC0 ma Power supply shutdown time 0. s/reset time 0. s W x H x 9 D Approx. 00 g Mounting brackets, unit label Open *When the prescale = * To widen the measurement range, the input pulse can be switched by stages between revolution pulse and revolution 0 pulses. Measurement Range Input pulse Switch A Side Switch B Side pulse / rotation 0 to 999 rpm Display at one-tenth value 0 pulse / rotation Display at 0 times value to 9,999 rpm Setting the Changing Switches Left Side of the Case B A Input Single Pulse Width Configuration of the Input Circuit Low Speed H L 0 ms or more 0 ms or more High Speed H L 0 µs or higher 0 µs or higher Input Single + V Each Input kω Up to ma 0 V Internal Circuit When each input terminal is short-circuited to the 0 V terminal, input turns. Switch Function Position A Position B Counting speed khz 0 Hz Decimal point Lighting position changes according to Decimal point combination. (See below.) Pulses / rotation pulses / rotation 0 pulses / rotation Setting the Lighting Position of the Decimal Point Switch KOYO ELECTRICS INDUSTRIES CO., LTD. A B A B A A B B Latest catalog (free) is available online. Visit our website

87 / Controller Terminal Connections Terminal Function Terminal Function 0 V 9 Not connected + V (For supplying to sensor) 0 Not connected Input 00 V AC 00 V AC * Different models for 00/00 V * No connection for terminal Not connected No. Example of Connection Proximity Sensor -wire DC System Rotary Encoder TC-L-G/H Connection/Dimensions -wire DC System Proximity sensors that can be connected APS series Models for which the output symbol is an E or N <Example> APS-GK-E * A two-wire DC system proximity sensor can be also connected. 0 9 INFORMATI The TRD-J-S can be connected as it consumes not more than 0 ma of current from a V power source. 9 0 Dimensions (Unit: mm) Stand F (For stationary installation) Panel-cut Dimensions for Embedded Installation 0. or M TC-V TC- Stand F (Sold Separately) 0±0. Stand B (Sold Separately) 0. Clamping Plate (For Embedded Installation) (Provided) Panel-cut Dimensions for Embedded Installation Socket for Embedded Installation: KB-0 (Sold Separately: Open Price) The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

88 / Controller INFORMATI KT-V Series Features - The KT-V series has a compact DIN size with an easy-to-see large display. - With characters represented by bright large red LEDs, mm high characters can be clearly seen from a distance and an angle. - The green LED is used for the set value to differentiate it from the measured values. - The set value can be easily set to using the setting key corresponding to each digit, like using a digital switch. - The TC-V series can be easily operated owing to a selection method that uses DIP switches for basic functional setting and the digit keys for detailed setting. Features Protection Functions for Each Key Key protection can be set for each key to prevent unintended operation. Retentive Memory without Battery Backup An EEPROM is used for memory storage and a battery that does not require maintenance is used. Removable Terminal Block This removable terminal block improves maintenance. After wiring, the terminal block cover enhances safety. CE Marking Compliant For Various Applications Using Operation Modes Delay On, delay, one-shot, integrating, and flicker can be set as the operation mode. Key Protection Function to Prevent Malfunction The KT-V series has a built-in key protection function so that settings are not changed if the key is pressed by mistake during operation. Elapsed Time / Remaining Time Display As the time display, the elapsed time and the remaining time can be selected. Power Source for High-capacity Sensor The AC type has a built-in V DC, 0mA power source for sensors. Sensors such as encoders and proximity sensors can be connected to the counter. Multi-voltage Power Supply for AC Type The AC type covers supply voltages of to V AC and can be used for any power source. Protection Fulfilling IP Sheet keys are used for the front panel, which enables users to safely operate the device even with wet or unclean hands. Conformity to CE and UL CE marking compliant and UL standard (UL0) certified product. Various Time Range The 0 time ranges cover from 0.00 sec to 9,999 hr. KT-V Model Number List Model Number Digit Power Source Power Source for Sensors V DC, 0 ma KT-VS AC Open KT-VS-C DC Open (Accessories) Mounting frame KT- V S - - Series Classification - Number of digits to display : digits - Output format S : With output - Power source type Blank : AC power C : DC power Price KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

89 / Controller General Specifications Items Rating AC Power Supply Voltage 00 to 0 V AC to V DC Allowable Power Range to V AC 0 to. V DC Power Consumption Approx. VA Approx. W KT-V Series Specifications DC Power INFORMATI Power Source for Sensors Power Failure Memory Ambient Temperature Storage Temperature Ambient Humidity Withstand Voltage V DC (0 to V) 0 ma (Ripple noise: 0% p-p or lower) EEPROM 0 to 0 C 0 to 0 C (No freezing) Number of overwrite cycles: 00,000 cycles or more Storage time: 0 years to %RH (No condensation) kv AC min (AC input, 0 V, between relay contacts) (DC power supply type: 0 V, only between relay contacts) Vibration Resistance Endurance Malfunction Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Impact Resistance Endurance Malfunction 90 m/s ms, axial directions 9 m/s ms, axial directions Noise Resistance Between power supply terminals. kv (Pulse width μs, start-up ns) Between power supply terminals.0 kv (Pulse width μs, start-up ns) Protective Structure IP (Only the front panel part) Weight Approx. 0 g Approx. 0 g Conforming cable 0. to. mm Terminal Block Conforming crimp terminal R.- Allowable tightening torque 0. Nm Performance Specifications Items Rating Type Timer Timing System On delay/off delay/one-shot/integrating/flicker (With prediction output) Digit digits Display Timing value display: Red LED, height of characters mm. Set value display: Green LED, height of characters mm Time Range Display Format Timer Accuracy Input Start Input Response External Reset Output Output Time (Flicker) Key Protection Installation Method 0.00 s to s/0.0 s to s/0. s to s/ s to 9,999 s/ s to 99 min 9 s/ min to 9,999 min / h to 9,999 h/ min to 99 h 9 min/0. min to min/0. h to h Elapsed time display / Remaining time display 0.0% or ms (Whichever is larger) Input logic: Negative logic (No-voltage input)/positive logic (Voltage input) Input resistance: Positive logic kωnegative logic. kω (AC power)/. kω (DC power) Input voltage: "L" 0 to V"H" to 0 V ms/ ms/ ms or less Minimum signal width: ms Non-contact output: NPN open collector output, V 00 ma, withstand voltage: V, residual voltage:. V or lower Contact output: transfer ( c), 0 V AC A (Resistance load) Variable from 0 to 9,990 ms, every 0 ms Any key setting is enabled. Dedicated to embedded installation (Terminal block connection) KT-V The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

90 INFORMATI KT-V / Controller Preset Values KT-V Series Output Operation Output Operation Chart On Delay Set Value Preset Values 0 Start Reset Contact Output Non-contact Output Preset Values Off Delay Set Value Preset Values 0 Start Reset Contact Output Non-contact Output Set Value One-shot Preset Values 0 Start Set Value Reset Preset Values Contact Output 0 Non-contact Output Start Reset Contact Output Non-contact Output Remaining Time Display Remaining Time Display Remaining Time Display Remaining Time Display : Prediction Set Value SW Elapsed Time Display Elapsed Time Display SW SW Elapsed Time Display Elapsed Time Display SW SW Power Contact Supply Output Non-contact Output Power Supply Flicker Flickering Set Valueis set in the setup mode. Preset Values Set Value 0 Remaining Time Display Remaining Time Display Preset Values Start 0 Reset Start Contact Output Reset t t t t Non-contact Output t t t t Contact Output The output time "t" can be changed from 0 to 9,990 ms (00 ms before shipment). Non-contact Output Elapsed Time Display Elapsed Time Display The output time "t" can be changed from 0 to 9,990 ms (00 ms before shipment). When the prediction set value is "0," : Prediction Set Value non-contact output becomes the same as the output operation of contact output. When the prediction set value is "0," The : prediction Prediction set Set value Valueshould non-contact be smaller output than the becomes set value. the same If the prediction setting value as exceeds the output the operation set value, of the contact prediction output. output (non-contact output) turns (or ) simultaneously with the The start prediction of the timer set value operation. should be smaller than the set value. If the prediction setting value exceeds the set value, the prediction output (non-contact output) turns (or ) simultaneously with the start of the timer operation. Integrating Remaining Time Display SW Elapsed Time Display Set Value Preset Values 0 Start Reset Contact Output Non-contact Output Power Supply KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

91 / Controller KT-V Series Connection Terminal Connection Diagrams KT-VS Power Source for Sensor Start Input V DC, 0 ma IN 0 V Non-contact Output OUT Reset Input R KT-VS-C Non-contact Output OUT Start Input IN 0 V Reset Input R INFORMATI 9 0 COM N.C. N.O. Contact Output 00 to 0 V AC Power Source * Non-contact output (OUT terminal) is also used for prediction output. * Do not connect anything to unconnected terminals. 9 0 COM N.C. N.O. Contact Output + to V DC Power Source Input/Output Circuit Diagrams AC Power DC Power Power Source for Sensor V DC Start Input. k k k V Internal V During Negative Logic Input 9 0 N.C. COM N.O. OUT V DC + Start Input V. k k k Internal V During Negative Logic Input 9 0 N.C. COM N.O. OUT V. k V. k Reset Input k k Reset Input k k 0 V 0 V KT-V The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

92 / Controller KT-V Series Connection INFORMATI Input Connection Examples NPN Open Collector Output Proximity Sensor - Input logic: Negative logic (No-voltage input) (neg) Recommended proximity sensor: APS--N/E Start Reset Brown Black Black Blue Power Source for Sensor V DC* Start Input Reset Input 0 V -wire DC System Proximity Sensor - Input logic: Negative logic (No-voltage input) (neg) Recommended proximity sensor: APS--Z * In the case of the DC power source type, the supply voltage should be not less than 0 V. Voltage Output or PNP Open Collector Output Proximity Sensor - Input logic: Positive logic (Voltage input) (pos) Recommended proximity sensor: APS--E Start Reset Brown Black Black Blue Power Source for Sensor V DC* Start Input Reset Input 0 V Start Start Input Reset Reset Input 0 V Switch Relay - Input logic: Negative logic (No-voltage input) (neg) - Start input response: ms * Because there is large input current, this connection is recommended. - Input logic: Positive logic (Voltage input) (pos) - Start input response: ms Power Source for Sensor V DC* KT-V Start Start Input Start Start Input Reset Reset Input Reset Reset Input 0 V 0 V * There is no power source for sensors in the case of the DC power source type. Use a separate external power source. Output Connection Examples NPN Open Collector Output Contact Output Relay Drive Possible OUT 0V Load + COM N.C. 9 Load Power Source for Load Power Source for Load Rated V DC N.O. 0 Load KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

93 / Controller KT-V Series Each Part Name and Function Panel Explanation Output display (Red) - Operation mode Lights up when the output is. Blinks when the prediction output is. Protection display (Red) - Operation mode Blinks when the key is protected. (Only when the key is ) - Setup mode Displays the set contents of key protection. RST key - Operation mode Resets the discrete value. (0 in increment mode, preset value in decrement mode) - Setup mode Select the setting item. Time Range s m h ms h m Timing / Set Value Display 0 to to to :00 to 99:9 0 :00 to 99:9 Unit Display h : m: s h : m: s h : m: s h : m: s h : m: s Discrete value display (Red) - Operation mode Displays the discrete value. - Setup mode Displays the set contents. Unit display - Operation mode Display the units of time. h: hour / m: minute / s: second Set value display (Green) - Operation mode Displays the set value. - Setup mode Displays the setting item. Digit key - Operation mode Changing the set value * If approx. sec passes without any key input after the set value has been changed, the set value becomes effective. - Setup mode Selects the set contents. INFORMATI Key Operation. Changes the preset value Every time a digit key is pressed, is added to the preset value of the corresponding digit. 0 9 * Approx. second after a digit key is released, the set value is entered. * In the case of digit of sexagesimal scale display : (Minute) (Second) (Hour) (Minute) Example: When the counter is Press the key and the Press the key and the Press the key and the KT-V. Resetting the timing value If the [RST] key is pressed (response time is 0. s), the timing value is reset. If the [RST] key is pressed, the timing value becomes the set value in the remaining time display mode and "0" in the passage display mode.. Key protection The key protection can be individually set for each operation key. If a key for which the key protection is set is pressed in the run mode, the LED corresponding to the pressed key blinks to notify that the operation is prohibited. Since the protection is set to all keys before shipment, if the power is supplied when DIP switch is, operation of all keys is prohibited. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

94 / Controller INFORMATI KT-V Series Each Part Name and Function DIP Switch Setting - Use the DIP switches at the top of the timer for setting. - Before operating the DIP switches, be sure that the power is turned off. The switches do not respond to setting changes while the power is on. - When a DIP switch is changed, be sure to press the [RST] key in the operation mode to reset the count value. Dip switch * The DIP switches are all set in the position before shipment. Selects the Operation Mode. Selects the Key Protection. Selecting the Display Format Selecting the Time Range Selecting the Output Mode Output Mode Select the output mode with DIP switches and. The flicker mode that is not included in the items is selected in the setup mode. Operation SW SW Operation Operation Integrating SW SW SW SW Integrating One-shot Integrating One-shot Delay One-shot Delay Delay On Delay On Delay On Time Range Select the time range with DIP switches,, and. The time range that is not included in the items is selected in the setup mode. Time Range SW SW SW Time Range SW hm Time Range SW SW SW SW SW hm hm h h m h m ms m ms ms s s.s s.s.s.s.s.s.s.s.s Display Format Select the display format with DIP switch. Display Format Elapsed Time Display Remaining Time Display SW KT-V Key Protection Select whether to engage the key protection or not with DIP switch. To engage protection, after setting each key in the setup mode, set DIP switch in the position and supply the power again to enable the protection. All keys are set for protection before shipment. Key Protection SW Key Protection Use SW Not Use Use Not Use Operation Mode Select the setup mode and the operation mode with DIP switch. Operation Mode Setup Mode Operation Mode SW 0 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

95 / Controller Setup Mode Make settings that cannot be selected with the DIP switches, in the setup mode. Setup Mode Setting Items () Start input response // ms () Input logic Positive logic, negative logic () Output mode Flicker mode, DIP switch () Time range 0.0 minute /0.0 time, DIP switch () Output time Set the output time of the flicker mode from 0 to 9,990 ms (in unit of 0 ms). () Prediction output Set the offset value for the set value. () Reset key protection Set the lock for the reset key. () Digit key protection Set the lock for the digit keys. Switching Between the Setup Mode and the Operation Mode Operating Mode Setup Mode When DIP switch is in the position and the power is turned on, the setup mode starts. When the DIP switch is in the position and the power is turned on, the operation mode starts. Operation of the Setup Mode Initialize the setup mode using the menu as shown in the table on the right. (Use the digit keys for all settings.) - Other than the flicker mode, skip the setting items with an * mark. - When the default setting is changed in the setup mode, be sure to press the [RST] key in the operation mode to reset the timing value. - The set contents become effective when moving to the next menu via the [RST] key. - The key protection setting becomes effective in AND conditions from DIP switch. If you want to make the protection effective, set DIP switch in the position. Digit key K/P display part : Not use : Lit when disabled : Use : Enabled when out To the next menu by pressing the reset key RST RST RST RST RST RST RST To the first menu by pressing the reset key RST KT-V Series Each Part Name and Function Start input response setting(int) Initial value: : Select a ms response. : Select a ms response. : Select a ms response. Input logic setting (si g) : pos Positive logic : neg Negative logic Output mode setting (t-op) : F Select the flicker mode. : dip Set the DIP switch. Time range settingrang : m Select 0.0 minute. : h Select 0.0 hour. : dip Set the DIP switch. Output time setting (outt) Digit key is disabled as the setting is performed in units of 0 ms. Discrete value display part s Digit key Prediction output setting (set ) Discrete value display part Digit key Reset key protection setting (rpro) Initial value: Locked Select whether to lock the reset key or not. Digit key: K/P display part : (Lock) : (Unlock) Digit key protection setting (ppro) Initial value: Locked Select whether to lock the reset key or not. Digit key: K/P display part : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) : (Lock)/ (Unlock) a Initial value: Initial value: Initial value: Initial value: 00ms Initial value: 0 INFORMATI KT-V The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

96 / Controller KT-V Series Example of Operation INFORMATI Operation Mode Changes the Preset Value Change the preset value from ":00" to ":0". The preset value becomes effective approx. second after the change is made. Before Changing Change Complete. Change the set contents To the next menu by pressing the reset key RST Start input responsesetting screen Change to the initial value. OUT K/P OUT K/P h : m: s RST OUT K/P h : m: s RST OUT K/P h : m: s RST OUT K/P h : m: s RST RST Input logic Setting screen Change to the initial value. OUT K/P Press setting key nine times Press setting key three times or continue to press and hold the key to display ". " or continue to press and hold the key to display ". " Washing Time Control If the start switch is pressed, washing is performed for the set time. RST RST Output mode Setting screen Change to the initial value. Time rangesetting screen Change to the initial value. OUT K/P OUT K/P Prediction output settingsetting screen RST Change to the initial value. OUT K/P KT-V Setting item Output Mode Time Range Display Format Key Protection Setting Item One-shot. Setting DIP switches Turn the power off before operating the DIP switches. Contents minutesecond Remaining time display Reset key Second key Select the output mode and one-shot. Select the time range: min sec Prohibition Set DIP switch is in the position. Set DIP switch is in the position. RST Press the reset key to end setup. RST Reset key protectionsetting screen Change to the initial value. Digit key protectionsetting screen Press the key and key to enable settings. This setting is complete.. Switching to the operation mode When setup is completed in the setup mode, turn the power off, set DIP switch in the position (to the operation mode) and turn the power.. Start the operation mode When the setting is changed in the setup mode, be sure to press the [RST] key after turning the power to reset the timing value. OUT K/P OUT K/P Set DIP switch is in the position. Set DIP switch and is in the position. Select the key protection. Set DIP switch is in the position.. Switching to the setup mode Set DIP switch in the position, and turn the power on. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

97 / Controller Common Errors Error Code Error Name Error details Corrective Action KT-V Series Error Code Display/Option Memory data error Preset value / Set value and the contents of the setup mode changed. Press the [RST] key and delete the error indication. The measured value and the timing value become "0", the preset value and the set value become "000", and the contents of the setup mode revert back to the preshipment defaults. INFORMATI Option Rubber Gasket Front Cover Option Model Number Contents Price KC-P KC-C If installed between the installation panel and KT-V, it prevents the intrusion of water into the control panel. If installed to the front panel, it protects the counter from exposure to dirt, etc. Material: Soft silicon rubber Key operation is enabled with the front cover installed. Open Open KT-V The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

98 / Controller INFORMATI KT-V Series Precautions Precautions in Use () The power source 0 V terminal and the input common 0 V terminal of the DC type are internally short-circuited. () Rather than gradually increasing the supply voltage, apply the rated voltage at once using a switch or relay. () When using the -wire DC system proximity sensor, set the input logic to negative logic. () If the preset value / set value is changed during measurement / timing, the changed value becomes effective approx. second after key input. () Enter the set contents of the DIP switches and the setup mode in the data sheet attached to the main body and keep it for maintenance. () Do not use the counter in the following environments. - Any place where the ambient temperature exceeds 0 C or falls to -0 C or lower. - Any place where the ambient humidity exceeds % or condensation occurs due to rapid temperature change. - Any place that is exposed to dust, iron powder, and corrosive gas. - Any place that is exposed to sunlight. - Any place where there are large vibrations or shocks. () When performing a dielectric voltage test or insulation resistance test, separate the main body from the control circuit. () When the power is shut down, the internal EEPROM is written. Since the number of writing cycles in the EEPROM is not more than 00,000, do not use the tachometer by highly frequent power source operations. Cautions in Wiring - Wire cables separately from power lines. - When using the counter in a place where a lot of noise is generated, separate the main body of the KT-V and the wiring from the noise sources as far as possible. - Do not use an unused terminal as a relay terminal. - It is recommended to use a crimp terminal for connections. - When wiring the cable to the terminals and, if the crimp terminal has a fork shape, do not attach it diagonally. For diagonal attachment, use a round crimp terminal. In the Case of a Forked Crimp Terminal If the crimp terminal is diagonally attached, the contact with the terminal becomes insufficient. Therefore, attach the crimp terminal horizontally from the side as shown in the figure above. In the Case of a Round Crimp Terminal Insert the main body into the attachment bore of the panel. How to Mount and Remove the Main Body How to Mount the Main Body Insert the main body into the attachment bore of the panel. - As the screw for anchoring the terminal block, only use the anchoring screw used in shipping. How to Mount - Make the Terminal sure that the Block allowable and tightening the Terminal torque is 0. Nm. Block Cover - Mount the terminal block cover after the wiring is completed. - As the screw for anchoring the terminal block, - As the screw for only anchoring use the the anchoring terminal screw block, used in shipping. only use the anchoring - Make sure screw that used the allowable in shipping. tightening torque is 0. Nm. - Make sure that - the Mount allowable the terminal tightening block torque cover is after 0. the Nm. wiring is completed. - Mount the terminal block cover after the wiring is completed. KT-V Attach the mounting frame from the backside. Body Attach the mounting frame from the backside. Mounting Frame: The frame can be mounted both in the longitudinal and transverse directions. Mounting Frame: The frame can be mounted both in the longitudinal and transverse directions. How to Remove the Main Body Pinch the levers to spread them to mm outwards. Pull out the frame while the levers are spread. Body Body Terminal Block Fixing Screw Terminal Block Terminal Block Cover Terminal Block Fixing Screw Fixing Screw Terminal Block Cover Terminal Block Cover Pinch the levers to spread them to mm outwards. Pull out the frame while the levers are spread. KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

99 / Controller KT-V Series Dimensions Dimensions (Unit: mm) Main Body of the KT-V Mounting Frame 0 (DC Power) 00 (AC Power) INFORMATI. to : Mounting Panel Thickness 0 0 DC Power AC Power Overall Depth mm 0 mm Terminal Block Detail Drawing Terminal Screw M Panel-cut Dimensions for Embedded Installation. When the mounting handle direction is in the transverse direction Mounting Frame 0 or more. When the mounting handle direction is in the longitudinal direction (Tight Mounting is Possible) 9.. or more Square Hole or more Conforming cable size : 0. to. mm Conforming crimp terminal : R.- Allowable tightening torque : 0. Nm KT-V The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

100 / Controller Controllers Lineup Controllers Lineup Model Number Appearance Type of Encoder Resolution (Digit) Number of Outputs Responsivity Supply Voltage Power Source for Sensors INFORMATI FC-F-C- Absolute encoder 0/0 00 min - /0 resolution 0 min - /0 resolution / V DC 9 W x 0 H x 0. D FC-F-C- Absolute encoder 0/0 00 min - / 0 resolution 00 min - /0 resolution (No advancing setting) / V DC 0 W x 90 H x 0. D FC-F-C- Absolute encoder 0/0 00 min - / 0 resolution 00 min - /0 resolution (No advancing setting) to V AC Dedicated to encoder + V 0 ma 0 W x 90 H x 0. D FC-0-C- Absolute encoder 0/0 00 min - /0 resolution 0 min - /0 resolution / V DC 0 W x 00 H x D FC-0- Absolute encoder 0/0 00min - / 0 resolution 00 min - /0 resolution to V AC Dedicated to encoder + V 0 ma FC-F FC-F/F FC-0 FC-0/0 0 W x 00 H x D FC-0- Absolute encoder 0/0 00 min - / 0 resolution 00 min - /0 resolution (No advancing setting) to V AC Dedicated to encoder + V 0 ma 9 W x 00 H x D KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

101 / Controller FC Series Correlation List Compatibility Between FC and FC Series (Unit: mm) Surface-Mount Installation TypeFC-0 Items Difference FC-0 FC-0 Model Number FC-0-C (Noted in Japanese) FC-0-C- (Noted in English) Dimensions 0.0 W x 00.0 H x.0 D No change Installation Method DIN rail / screwed No change Power Supply 0. V to. V DC No change Function / Performance Encoder-connecting Connector FC-0-C- (Noted in English) No change Manufacturer Not compatible Protrusion Dimension Encoder TRD-NANWF Usable TRD-NANWF TRD-NANWE Usable. 0.9 Conversion cable F-GF- 0 is required. Conversion cable F-GF is required. Usable Junction Cables F-GF F-GF Surface-Mount Installation TypeFC-0 Items Difference FC-0 FC-0 Model Number FC-0 (Noted in Japanese) FC-0- (Noted in English) Dimensions 0.0 W x 00.0 H x.0 D No change Installation Method DIN rail / screwed No change Power Supply V to V AC No change Function / Performance Encoder-connecting Connector Conversion cable F-GF is required. FC-0- (Noted in English) No change Manufacturer Not compatible Protrusion Dimension Encoder TRD-NANWF Usable TRD-NANWF TRD-NANWE Usable. 0.9 Conversion cable F-GF- 0 is required. Conversion cable F-GF is required. Usable Junction Cables F-GF F-GF Surface-Mount Installation TypeFC-0 Items Difference FC-0 FC-0 Model Number FC-0 (Noted in Japanese) FC-0- (Noted in English) Dimensions 9.0 W x 00.0 H x.0 D No change Installation Method DIN rail / screwed No change Power Supply V to V AC No change Function / Performance Encoder-connecting Connector Conversion cable F-GF is required. FC-0- (Noted in English) No change Manufacturer Not compatible Protrusion Dimension Encoder TRD-NANWF Usable TRD-NANWF. 0.9 TRD-NANWE Usable Conversion cable F-GF- 0 is required. Conversion cable F-GF is required. Usable Junction Cables F-GF F-GF Conversion cable F-GF is required. Embedded Installation TypeFC-F Items Difference FC-F FC-F Model Number Dimensions (Connector Connection) FC-F-C (Noted in Japanese) FC-F-C- (Noted in English) 9.0 W x 0.0 H x 0. D 9.0 W x 0.0 H x 0. D FC-F-C- (Noted in English) No change 9.0 W x 0.0 H x. D Installation Method Panel cutout / Mounting brackets No change Panel Cutout Dimensions 90.0 W x.0 H No change Thickness of Mounting Plate 0. to.0 No change Power Supply 0. V to. V DC No change Function / Performance No change Encoder-connecting Connector Manufacturer Not compatible Position Not compatible Encoder TRD-NANWF Usable Conversion cable F-GF is required. TRD-NANWF Conversion cable F-GF- 0 is required. Usable TRD-NANWE Usable Conversion cable F-GF is required. Junction Cables F-GF F-GF Embedded Installation TypeFC-F Items Difference FC-F FC-F Model Number Dimensions (Connector Connection) FC-F-C (Noted in Japanese) FC-F-C- (Noted in English) 0.0 W x 0.0 H x 0. D 0.0 W x 0.0 H x 0. D FC-F-C- (Noted in English) No change 0.0 W x 0.0 H x. D Installation Method Panel cutout / Mounting brackets No change Panel Cutout Dimensions.0 W x.0 H No change Thickness of Mounting Plate 0. to.0 No change Power Supply 0. V to. V DC No change Function / Performance No change Encoder-connecting Connector Manufacturer Not compatible Position Not compatible Encoder TRD-NANWF Usable Conversion cable F-GF is required. TRD-NANWF Conversion cable F-GF- 0 is required. Usable TRD-NANWE Usable Conversion cable F-GF is required. Junction Cables F-GF F-GF Embedded Installation TypeFC-F Items Difference FC-F FC-F Model Number Dimensions (Connector Connection) FC-F-C (Noted in Japanese) FC-F-C- (Noted in English) 0.0 W x 0.0 H x 0. D 0.0 W x 0.0 H x 0. D FC-F-C- (Noted in English) No change 0.0 W x 0.0 H x. D Installation Method Panel cutout / Mounting brackets No change Panel Cutout Dimensions.0 W x.0 H No change Thickness of Mounting Plate 0. to.0 No change Power Supply 0. V to. V DC No change Function / Performance No change Encoder-connecting Connector Manufacturer Not compatible Position Not compatible Encoder TRD-NANWF Usable Conversion cable F-GF is required. TRD-NANWF Conversion cable F-GF- 0 is required. Usable TRD-NANWE Usable Conversion cable F-GF is required. Junction Cables F-GF F-GF INFORMATI FC-F FC-F/F FC-0 FC-0/0 The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD.

102 / Controller INFORMATI FC-F FC-F/F FC-0 FC-0/0 Descriptions of Terms Preset The input pulse signal is counted, and if the number of input pulses reaches the numeric value preset by the setter, output is produced. The block diagram of the preset counter is as shown in the figure below. Block diagram KCX series Count Input Reset Input Double Preset The double preset counter has two sets of setters and two output circuits, and can output in the set values. Total The total counter only displays the discrete value and does not have control output. Consolidated One consolidated counter has the built-in functions of several counters, and when any one of the counters reaches its preset value, it produces output. The consolidated counter is most suitable for the maintenance of several tools as needed by tool replacement for machining centers and NC machine tools. A-Type Operation (Specific time output operation) Automatic Reset Repetition - If the number of input pulse signals reaches the preset value (count up), the output is produced for a specific period of time. - If the counter counts up, the internal counting circuit is automatically reset and the next input signal can be counted even during output time. - If you want to reset the internal counting circuit during counting, turn the reset terminal (external reset) or shut down the power temporarily (power source reset). Count Input Output B-type Operation (Self-holding output operation) - If the number of input pulse signals reaches the preset value, output is produced and held. - If the reset terminal turns (external reset) or the power source is temporarily shut down (power source reset), the internal counting circuit and the output holding circuit reset. Count Input Input Circuit Reset Circuit Setter Preset First Digit Display Circuit First Digit Count Circuit Set Value AND Circuit Power Source Second Digit Display Circuit Second Digit Count Circuit Specific Time Output Set Value Output Circuit Nth Digit Display Circuit Nth Digit Count Circuit Non-contact Output (Contact Output) Power Source for Sensor Non-contact Signal Input and Contact Signal Input A non-contact signal input is an input signal that triggers the output of a semiconductor circuit such as transistor (non-contact output of proximity sensor, photoelectronic sensor, or rotary encoder). A contact signal input is an signal input triggered by a micro switch, limit switch, push button switch, or relay. Sensor Sensor Non-contact Signal Output and Contact Signal Output A non-contact signal output is a signal output from a semiconductor circuit. The contact output is a signal output from relay contact built into a counter. Open Collector Output Since this circuit is not internally connected to a power source, it is necessary to externally connect a power source and load. Voltage and current can be freely selected within the standards of the counter. (Only N load) From Previous Step Totem-pole Output A kind of non-contact output, a totem-pole output circuit has transistors Q and Q of the output circuit connected in series with the output extruding from the intermediate point as shown in the figure below.therefore, a totempole output circuit can take out larger current compared with conventional non-contact output. (Both P load and N load) A totem-pole output circuit is used in the same way as conventional noncontact output, but can directly drive the relay. V From Previous Step OUT Non-contact Signal Input E N.C C N.O Contact Signal Input Preset Open Collector Output +Power Source OUT E Relay Q + V Power Source for Sensor Input terminal E + V Power Source for Sensor Input terminal E N.C C N.O OUT E (Grounding) Load L Contact Signal Input Non-contact Signal Input DC Power OUT Output Holding Output Q External Reset Input KOYO ELECTRICS INDUSTRIES CO., LTD. E Latest catalog (free) is available online. E Visit our website

103 / Controller Descriptions of Terms Maximum Counting Speed The maximum counting speed shows up to what pulses the input pulse signal of the make ratio : Ta=Tbcan be counted per second, and uses Hz as the unit. If the make ratio is not : as shown in () and () below, the input pulse signal width is limited by Ta MIN. or Tb MIN. Ta MIN. = Tb MIN. = (s) Maximum Counting Speed * This numeric value is provided in the specifications of each model. () Ta = Tb Can be counted if Ta or Tb is longer than Ta MIN. or Tb MIN. Input Pulse Signal () Ta Tb Can be counted if Ta is longer than Ta MIN. Input Pulse Signal () Ta Tb Can be counted if Tb is longer than Tb MIN. Input Pulse Signal Ta Ta If the non-contact signal is added as the input pulse signal, the input terminal can be selected according to the counting speed (frequency). If the contact signal is added, the input terminal with the lowest maximum counting speed should be used. Reset - Power source reset The power source reset operates after a certain period of time when the power is supplied. If you want to operate it at any given time, the power source can be reset by shutting down the power once and supplying it again. - Automatic reset The automatic reset operates when the counter is used in the A-type operation, and it operates for a certain period of time after the counter counts up. Since this time is shorter than the period of input of the maximum counting speed of the counter, the counter encounters no counting errors and starts counting from "0" again even while counting consecutive inputs. - External reset The external reset operates while the predetermined voltage is applied to the reset input terminal. (Some models operate the external reset with an "L" level.) - Manual reset The manual reset operates while the push button on the counter surface panel is pressed by manual operation. Tb Ta=TbTa MIN.=Tb MIN. Tb Ta TaTa MIN. Tb TbTb MIN. Banks A bank refers to the number of programs. Each bank can be separately programmed (operation setup). Explanation of the Technical Terms in the Specifications Counting Input Inhibit Gate (Responsivity) Delay time: The time until the counting input is shut down after the input of the counting input inhibit gate turns. Delay time: The time until counting is enabled after the input of the counting input inhibit gate turns. External Setting Input (Responsivity) Delay time: The time until the set circuit starts operating after the external setting input turns. Delay time: The time until the set circuit stops operates after the external setting input turns. External Reset (Responsivity) Delay time: Delay time: The time until the reset after the reset input turns. Delay time: The time until the counting is enabled after the reset input becomes. Power Source Reset (Reset time) The time until counting is enabled after the power is resupplied after the power source has been reset. Automatic Reset (Reset time) The time until counting is enabled again after the counting circuit is reset simultaneously with count overflow. Non-contact Output (Responsivity) The time until the output signal is produced in the non-contact output terminal after the final pulse reaching the preset value enters the counting input terminal. Contact Output (Responsivity) The time until the N.O. contact point of the output relay closes after the final pulse reaching the preset value enters the counting input terminal. Output Prohibition Gate (Responsivity) Delay time: The time until the generation of an output signal is prohibited after the input of the output prohibition gate turns. Delay time: The time until the generation of an output signal is enabled after the input of the output prohibition gate turns. INFORMATI FC-F FC-F/F FC-0 FC-0/0 Power Source for Sensors The counter can supply power to the outside from this power source. Since the power source can be used for supplying power to proximity sensors, photoelectronic sensors, and rotary encoders, the connection with various types of sensors becomes easy. Koyo s' electronic counters have a built-in power source for sensors. (Excluding the DC type) The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

104 / Controller INFORMATI FC-F, FC-F/F Features Embedded Installation Type Controller - The embedded installation type of programmable cams enable constant checking of the operating state from a control panel. - The programmable cams have enhanced features such as advancing, abnormality detection, and a multipurpose communication port. Features - Obtained advanced safety certification The programmable cams can be used in Category applications of EN9-, safety integrity level (SIL) of IEC0, and the performance level e of ISO9-: 00. Users can easily and securely create a safe environment that conforms to international standards. - Reliable operation based on high level selfdiagnosis The CPU module and the input-output module are equipped with selfmonitoring capabilities that constantly monitor for undervoltage and overvoltage, grasp connection and operation status by test pulse, and crosscheck switching by channel monitoring. - Easy tooling changes Since the FC-F-C- can register programs and the FC-F-C- can register 0 programs, any program can be selected by switching the bank input at the time of tooling change. - Supporting a wide range of industries The programmable cams are most suited for the timing control of various kinds of filling machines, wrapping machines, coaters, and bottling machines in the food, packaging, and printing industries. - Surface-Mount types also available Surface-Mount type of programmable cams are available in the FC- 0-C-/FC-0-/FC Automatic correction of advancing angle (FC-F-C-/FC-F-C-) If the timing of the machine that changes its rotating speed is controlled by a programmable cam, the difference in operation timing due to actuator delays becomes the problem. The automatic advancing function corrects this timing difference by outputting the angle equivalent to the operation delay time of the actuator earlier according to the angle calculated from the rotating speed at that time. Advancing Angle Advancing Angle FC-F FC-F/F FC-0 FC-0/0 Setting Angle Low Speed Medium Speed High Speed [Applications] - Changing the speed at startup and stopping - Devices that change speed - Devices that require speed control 90 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

105 / Controller General Specifications Supply Voltage FC-F, FC-F/F Specifications Items FC-F-C- FC-F-C- FC-F-C- Power Supply Pressure Fluctuation Range / V DC 0. to. V DC Power Consumption W W INFORMATI Ambient Operating Temperature Storage Temperature 0 to 0 C 0 to 0 C (No freezing) Use / Storage Ambient Humidity Surrounding Atmosphere in Place of Use Vibration Resistance Impact Resistance Noise Resistance Protective Structure to % RH (No condensation) No corrosive gases Endurance: Displacement amplitude: 0. mm, frequency: 0 to Hz, axial directions Endurance: 00 m/s, axial directions Between power supply terminals:.0 kv Pulse width μs/start-up ns/square wave pulse IP: Only the surface sheet Between power supply terminals:. kv Size (mm) 9 W x 0 H x. D 0 W x 90 H x. D 0 W x 90 H x. D Weight (g) Function/Performance Specifications Items FC-F-C- FC-F-C- FC-F-C- Number of Input Points Starting input: point/ Protection input: point/ Origin input: point Starting input: point/ Bank input: points/ Protection input: point/ Origin input: point Starting input: point/ Bank: points/ Protection input: point/ Origin input: point Encoder Input H:. V ()/L: 0 to V ()H:. to 0 V ()/L: 0 to V () Resolution: 0/0 per revolution (Output code: Gray binary) Control Input H:. V to 0 V ()/L: 0 to V Number of Outputs points points points Output Specifications NPN open collectorwithstanding voltage V or lower / Current 0. A or lower Number of Output Area Settings settings settings settings Response Rotating Resolution 0: 00/ Speed Resolution 0: 0 min - Resolution 0: 00/ Resolution 0: 00 Resolution 0: 00/ Resolution 0: 00 FC-F FC-F/F Output Response Time 0 μs or less 0 μs or less 0 μs or less Power Supply Start Time s or less Number of Banks No (Banks 0 to ) 0 (Banks 0 to 9) Program Memory EEPROM Resolution 0/0 per revolution (Switched from a DIP switch) FC-0 FC-0/0 CW/CCW Direction Switching Switched from a DIP switch RUN Output during normal operation in the operation and adjustment modes (Switched from a DIP switch) Display Switching Angle / Rotating speed (Switched from a DIP switch) Origin Correction Arbitrary point becomes the origin. Special Features Protection function Protection function, copy function, pulse output function, communication function Communication RS-CProtocol dedicated to FC Advancing Function No Available Available Accessories Mounting brackets Price Open Open Open The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

106 / Controller INFORMATI FC-F Each Part Name and Function Panel Explanation Status display - Displays the angle / rotating speed. Angle / Rotating speed display - Displays the angle / rotating speed. Origin key - Corrects the origin. Output display - Displays the / state of output. - Lights the output No. designated by the [Output] key. Start input display External origin input display Front Front HOME Back START HOME GOOD FC-F-C- ANALOG r/min PRG M FC-F-C- PRG TCH TEST RUN MODE OUT CLR SELECT WRITE READ ENT Operation key Sets the status display. DIP switches Terminal block - Provided with the cover Front Back Normal display DC+ DC HOME I.C CCW 0 RUN Connector for encoder POWER ST PRO 0 O.C 0. to.v DC CW 0 CAM Connection Wiring DC+ DC HOME I.C ST PRO 0 O.C FC-F FC-F/F FC-0 FC-0/0 Fuse Output Common Power Source for / V DC Power Source Starting Input Load 0 Output Power Source for Load V DC or lower External Origin Input Protection Input (Connected for Protection). The external origin input should be connected to a non-contact output that has no chattering.. The output common (O.C) and input common (I.C) are internally short-circuited with the power source-(dc-) terminal. 9 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

107 / Controller Default Setting Default Setting Power Setting DIP Switches Power CCW 0 RUN CW 0 Setting for shipment from factory FC-F Operation Setting Switch : Select the rotation direction. CW: Increases the angle in clockwise rotation as seen from the axle side of the encoder. CCW: Increase the angle in counterclockwise rotation as seen from the axle side of the encoder. Switch : Select the resolution of the encoder. 0: When using an encoder of 0 resolution / revolution 0: When using an encoder of 0 resolution / revolution Switch : Select when using the RUN output. CAM: When using all output as CAM output RUN: When using a specific output as the RUN output* * Specific output that enables RUN output FC-F-C: Output FC-F-C: Output FC-F-C: Output The RUN output turns during normal operation in the operation and adjustment mode, and when an error occurs. INFORMATI Delete All the Output Area Settings - Setting or teaching mode Delete all the output area settings. [Delete] [Write] [Execute] Deletion of Origin Correction - Teaching mode Delete the origin correction. FC-F-C: Banks 0 to [Delete] [Origin] [Execute] FC-F-C: Banks 0 to 9 Note) The deletion operation is required for each bank. Initial Setting Complete Setting - Setting and teaching mode Set the output area and set, change, or delete the origin correction. NG NG OK Adjustment Check if the output area setting / origin correction value are correct - Adjustment mode Fine-tune the output area setting in the test run. (If not necessary, operate the programmable cam in the run mode.) Check if output is appropriate. OK - Operation mode Run Operate the programmable cam. FC-F FC-F/F FC-0 FC-0/0 The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

108 / Controller FC-F Operation Setting List of Operations Operation Mode Function Operating Procedures Setting Teaching Adjustment Operation INFORMATI Switching of Operation Mode Select the mode with the [Mode] key. The mode is selected from the current mode sequentially. Setting Teaching Adjustment Operation The mode selected with the [Execute] key is determined and becomes the operation mode. Display Switching The angle display and the rotating speed display are alternately switched with the [Display] key. Designation of Bank No. Press the [Bank] (*) key and designate the bank No. Designation of Output No. Readout of Output Area Setting Deletion of One Output Area Setting Deletion of All Output Area Settings of Designated Output Press the [Output ] key or the [ Output] (*) key, and designate output. Every time the key is pressed, the lighting position of the output display changes. Designate the bank No. (*) and the output No., and press the [Readout ] (*) or the [Readout ] key. The and angle are alternately read out. After reading out the output area setting you want to delete, press the [Delete] [Execute] keys to delete the read-out output area setting. Designate the bank No. (*) and the output No., and press the [Delete] [Output ] (or [ Output] (*)) [Execute] keys to delete the settings. Deletion of All Output Area Settings in Designated Bank Designate the bank No. (*) and press the [Delete][Bank][Execute] keys to delete the settings. However, the origin correction setting is not deleted. Note FC-F FC-F/F FC-0 FC-0/0 9 Deletion of All Output Area Settings 0 Writing of Output Area Setting Writing of Output Area Setting (Teaching) Setting of Origin Correction Deletion of Origin Correction Change of Output Area Setting Fine-Tuning of Output Area Setting During Operation (Enabled Only when Starting Input is ) (* mark): FC-F-C- does not have the [Bank], [ Output], and [Readout ] keys. Regarding the operation for setting special features, see the operation manual. Note ) FC-F-C-/FC-F-C- are abolished. Press the [Delete][Write][Execute] keys to delete the settings. However, the origin correction setting is not deleted. Designate the bank No. (*) and the output No. Display the angle you want to set with the [+] key or the [-] key, and write it with the [Write] key. (The angles are set in the order of angle and angle.) Designate the bank No. (*) and the output No. Rotate and then stop the encoder at the position you want to set, and write the output area setting with the [Write] key. (The angles are set in the order of angle and angle.) Set the bank No. (*),rotate the encoder and then stop it at the mechanical origin, and press the [Origin] key to select the angle of origin. With the operation of the [Write] key, the origin is written and the position becomes 0. Set the bank No. (*) and press the [Delete][Origin][Execute] keys to delete the origin correction. The output angle of the encoder is displayed as it is. Read out the angle or angle set value you want to change. Press the [+] key or the [-] key, and display the set value you want to change. Then, press the [Write] key and write the changed value. Read out the angle or angle set value you want to change. The angles increase with the operation of the [+] key. The angle decreases with the operation of the [-] key. Simultaneously with the completion of changes (fine-tuning), the output operation changes. List of Error Codes Error Code Display Contents Description Cause / Corrective Action E Rotary encoder connection error The designation of the resolution of the rotary encoder does not correspond to the designation of the resolution of the programmable cam. - Setting of the DIP switch is different. - Check the resolution of the rotary encoder. - Failure of the rotary encoder. E9 E0 Rotary encoder code error The output of a rotary encoder that does not exist was detected. The rotary encoder code is discontinuous. - Failure of the rotary encoder (Unconnected). - Disconnection or short-circuit of the connection cable of the rotary encoder. - Effects of exogenous noise. E Memory change error The contents of set values (output, origin correction, and advancing) have been changed. - Effects of excessive noise. - Delete all the set values and reenter all settings. E0 Rotational speed error The programmable cam cannot respond to the rotating speed of the rotary encoder. - Check the rotating speed of the rotary encoder. - Check the resolution of the rotary encoder. Set Value LED Blinking Bank Display A to F Setting value error The output area setting is duplicated. The output area setting is protected. - After deleting or changing the duplicated set value, reset the set value. - Check the protection input. Bank error A bank that does not exist is designated in the bank input. - Check the bank input. 9 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

109 / Controller FC-F Dimensions Dimensions (Unit: mm) Body of the FC-F-C INFORMATI 0 FC-F-C- Panel-cut Dimensions for Embedded Installation Panel thickness 0. to mm 90± 0. ± 0. R0 to. FC-F FC-F/F FC-0 FC-0/0 The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 9

110 / Controller FC-F/F Each Part Name and Function INFORMATI Panel Explanation Status display - Displays the Bank / FUN Bank / FUN display Angle / Rotating speed display - Displays the angle / rotating speed. Bank / FUN key Output display - Displays the / state of output. - Lights the output No. designated by the [Output] key. Start input display External origin input display Normal display Sets the status display. Operation key Origin key - Corrects the origin. Mode display Connector for output Connector for encoder Mode display Connector for communication - Connection cable: Z-0JP (Sold separately) (RS-C modular pins) Terminal block - Provided with the cover Front Back BANK BANK FUN FUN ANALOG r/min PRG M FC-F-C START HOME GOOD HOME DC+ PRG TCH POWER 0 DC FC-F-C- * The FC-F-C- displays output for points. ST O.C B0 TEST RUN 9 0 B 0. to.v DC B O.C OUT MODE HOME PRO I.C OUT CLR CCW CW 0 0 SELECT WRITE READ READ ENT RUN CAM Connection Wiring DC+ DC ST B0 B B B HOME PRO I.C FC-F FC-F/F FC-0 FC-0/0 Power Source for / V DC Power Source Starting Input 0 Bank Input Input Common Protection Input (Connected for Protection) External Origin Input. Bank input is equipped only on the FC-F-C.. The external origin input should be connected to a non-contact output that has no chattering.. The output common (O.C) and input common (I.C) are internally short-circuited with the power source-(dc-) terminal. Connector Arrangement FC-F-C Use Range 0 O.C O.C 9 O.C 9 0 O.C FC-F-C Use Range Load Fuse Power source for Load V DCV or lower 9 0 Output Output Output Output KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

111 / Controller Connection Connector Switch Terminal Unit FC-F/F Operation Setting U-JT TF-D Cable for Connecting a and the TF-D Terminal Unit INFORMATI FC-F-C FC-F-C ( m Cable) U-0JH ( m Cable) LC-0 (0P Connector) LC-00 FUJITSU COMPENT LIMITED Connector : FCN-J00-AU Cover : FCN-0C00-J Terminal Unit Connection Cable (TF-D) U-0JT m Open price U-0JH m Open price One-end Loose Wire Cable U-0JT m Open price LC-0 m Open price U-0JT m Open price 0P Connector LC-00 Open price Default Setting Default Setting Power Setting DIP Switches Power Delete All the Output Area Settings CCW 0 RUN CW 0 Setting for shipment from factory Switch : Select the rotation direction. CW: Increases the angle in clockwise rotation as seen from the axle side of the encoder. CCW: Increase the angle in counterclockwise rotation as seen from the axle side of the encoder. Switch : Select the resolution of the encoder. 0: When using an encoder of 0 resolution / revolution 0: When using an encoder of 0 resolution / revolution Switch : Select when using the RUN output. CAM: When using all output as CAM output RUN: When using a specific output as the RUN output* * Specific output that enables RUN output FC-F-C: Output FC-F-C: Output FC-F-C: Output The RUN output turns during normal operation in the operation and adjustment mode, and when an error occurs. - Setting or teaching mode Delete all the output area settings. [Delete] [Write] [Execute] FC-F FC-F/F FC-0 FC-0/0 Deletion of Origin Correction - Teaching mode Delete the origin correction. FC-F-C: Banks 0 to [Delete] [Origin] [Execute] FC-F-C: Banks 0 to 9 Note) The deletion operation is required for each bank. Initial Setting Complete Setting - Setting and teaching mode Set the output area and set, change, or delete the origin correction. NG NG OK Adjustment Check if the output area setting / origin correction value are correct Check if output is appropriate. OK - Operation mode Run Operate the programmable cam. The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. - Adjustment mode Fine-tune the output area setting in the test run. (If not necessary, operate the programmable cam in the run mode.) KOYO ELECTRICS INDUSTRIES CO., LTD. 9

112 / Controller FC-F/F Operation Setting List of Operations Operation Mode Function Operating Procedures Setting Teaching Adjustment Operation INFORMATI Switching of Operation Mode Select the mode with the [Mode] key. The mode is selected from the current mode sequentially. Setting Teaching Adjustment Operation The mode selected with the [Execute] key is determined and becomes the operation mode. Display Switching The angle display and the rotating speed display are alternately switched with the [Display] key. Designation of Bank No. Press the [Bank] (*) key and designate the bank No. Designation of Output No. Readout of Output Area Setting Deletion of One Output Area Setting Deletion of All Output Area Settings of Designated Output Press the [Output ] key or the [ Output] (*) key, and designate output. Every time the key is pressed, the lighting position of the output display changes. Designate the bank No. (*) and the output No., and press the [Readout ] (*) or the [Readout ] key. The and angle are alternately read out. After reading out the output area setting you want to delete, press the [Delete] [Execute] keys to delete the read-out output area setting. Designate the bank No. (*) and the output No., and press the [Delete] [Output ] (or [ Output] (*)) [Execute] keys to delete the settings. Deletion of All Output Area Settings in Designated Bank Designate the bank No. (*) and press the [Delete][Bank][Execute] keys to delete the settings. However, the origin correction setting is not deleted. Note FC-F FC-F/F FC-0 FC-0/0 9 Deletion of All Output Area Settings 0 Writing of Output Area Setting Writing of Output Area Setting (Teaching) Setting of Origin Correction Deletion of Origin Correction Change of Output Area Setting Fine-Tuning of Output Area Setting During Operation (Enabled Only when Starting Input is ) (* mark): FC-F-C- does not have the [Bank], [ Output], and [Readout ] keys. Regarding the operation for setting special features, see the operation manual. Note ) FC-F-C-/FC-F-C- are abolished. Press the [Delete][Write][Execute] keys to delete the settings. However, the origin correction setting is not deleted. Designate the bank No. (*) and the output No. Display the angle you want to set with the [+] key or the [-] key, and write it with the [Write] key. (The angles are set in the order of angle and angle.) Designate the bank No. (*) and the output No. Rotate and then stop the encoder at the position you want to set, and write the output area setting with the [Write] key. (The angles are set in the order of angle and angle.) Set the bank No. (*),rotate the encoder and then stop it at the mechanical origin, and press the [Origin] key to select the angle of origin. With the operation of the [Write] key, the origin is written and the position becomes 0. Set the bank No. (*) and press the [Delete][Origin][Execute] keys to delete the origin correction. The output angle of the encoder is displayed as it is. Read out the angle or angle set value you want to change. Press the [+] key or the [-] key, and display the set value you want to change. Then, press the [Write] key and write the changed value. Read out the angle or angle set value you want to change. The angles increase with the operation of the [+] key. The angle decreases with the operation of the [-] key. Simultaneously with the completion of changes (fine-tuning), the output operation changes. List of Error Codes Error Code Display Contents Description Cause / Corrective Action E Rotary encoder connection error The designation of the resolution of the rotary encoder does not correspond to the designation of the resolution of the programmable cam. - Setting of the DIP switch is different. - Check the resolution of the rotary encoder. - Failure of the rotary encoder. E9 E0 Rotary encoder code error The output of a rotary encoder that does not exist was detected. The rotary encoder code is discontinuous. - Failure of the rotary encoder (Unconnected). - Disconnection or short-circuit of the connection cable of the rotary encoder. - Effects of exogenous noise. E Memory change Error The contents of set values (output, origin correction, and advancing) have been changed. - Effects of excessive noise. - Delete all the set values and reenter all settings. E0 Rotational speed error The programmable cam cannot respond to the rotating speed of the rotary encoder. - Check the rotating speed of the rotary encoder. - Check the resolution of the rotary encoder. Set Value LED Blinking Bank Display A to F Setting value error The output area setting is duplicated. The output area setting is protected. - After deleting or changing the duplicated set value, reset the set value. - Check the protection input. Bank error A bank that does not exist is designated in the bank input. - Check the bank input. 9 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

113 / Controller FC-F/F Dimensions Dimensions (Unit: mm) Body of the FC-F-C-/F-C- 9.. INFORMATI 90 FC-F-C FC-F-C- * The FC-F-C- displays output for points. Panel-cut Dimensions for Embedded Installation Panel thickness 0. to mm ± 0. ± 0. R0 to. Manual Name of Reference Contents FC Series Operation Manual How to operate the FC-F-C-, FC-F-C-/F-C- The manuals above can be downloaded from our website at FC-F FC-F/F FC-0 FC-0/0 The specifications and prices described in this catalog were valid when the catalog was issued. For the latest information, contact our sales persons or see our website. KOYO ELECTRICS INDUSTRIES CO., LTD. 99

114 / Controller INFORMATI FC-0, FC-0/0 Features Surface-Mount Installation Type Controller - An electronic programmable cam that features usability and high performance in a compact body - The surface-mount installation type has three models according to the control scale. FC-F FC-F/F FC-0 FC-0/0 Features - Easy operation The programmable cams can be easily operated with the feeling of a digital switch. - Settings cannot be changed during operation. Using the adjustment mode, the / position can be fine-tuned without stopping the machine. - Easy tooling change Since the FC-0- can register programs and the FC-0- can register 0 programs, any program can be selected by switching the bank input at the time of tooling change. - Automatic correction of advancing angle (FC-0-) To correct the response delay of a machine (actuator), the programmable cam has built-in output points that can automatically correct the / timing of the CAM output according to the change in the number of revolutions. - Equipped with multipurpose communication ports (FC-0-, FC-0-) If the ports are used in communications with a PLC, the PLC can issue the operation commands to and change the set values of the programmable cams, and the programmable cams can read the angle and output state from the PLC. Programs can be copied between FC and FC. - Fully equipped with an enhanced absolute type of rotary encoder as a sensor The lineup consists of the compact (outside diameter 0mm / depth mm) TRD-NA series, robust TRD-K series, and environmental-resistant TRD-KL series, which can be selected according to applications. - High position accuracy detection / control Since an optical absolute encoder is used for the sensor, the programmable cam can achieve much better linearity compared with resolvers. Moreover, it causes no errors even when the sensor is replaced. - High speed response 00 min - (00 min - when the resolution is 0) - Protection function that prevents malfunctions If the protection input is short-circuited after adjustments are made or before the shipment of a machine, this feature prevents end users from accidentally operating equipment, thus eliminating trouble. - Rotation state can be grasped at a glance. The programmable cams are equipped with a roulette display that enables users to grasp the rotation direction and rotation position at a glance. - Equipped with an origin correction function. It is not necessary to align the angle to mount an encoder. - DIN rail installation The installation on DIN rails and screws are both supported. - Battery-less No battery is required owing to an onboard EEPROM. 00 KOYO ELECTRICS INDUSTRIES CO., LTD. Latest catalog (free) is available online. Visit our website

KCN-S/KCN-W. Merits. Single/Dual Preset Counters for Addition and Subtraction. Electronic. Counters

KCN-S/KCN-W. Merits. Single/Dual Preset Counters for Addition and Subtraction. Electronic. Counters Single/Dual Preset for and Electronic KCN-S/W KCN-A KCV Maximum counting speed: cps, 1kcps, kcps or kcps (selected by digit keys) With the DIN standard size of only 8 mm by 8 mm, the full featured counter

More information

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings for Display of High-speed Addition and Subtraction Maximum operating speed 2kHz Used in industrial machinery, end-measuring devices, and the like, this electronic counter is exclusively for display. It

More information

Electronic Counters / Controllers General Catalog Vol.3 KOYO ELECTRONICS INDUSTRIES CO., LTD.

Electronic Counters / Controllers General Catalog Vol.3 KOYO ELECTRONICS INDUSTRIES CO., LTD. Electronic / Controllers General Catalog Vol. KOYO ELECTRICS INDUSTRIES CO., LTD. ELECTRIC COUNTERS List of KOYO Electronic B- Selection Guide B- KCV Single Preset for Addition and Subtraction /Total

More information

KCX series. Electronic. Counters B-32

KCX series. Electronic. Counters B-32 B-32 KCX series KCX-1 KCX-2 KCX-3 KCX-4 KCX-1D KCX-2D KCX-2DM KCX-3D KCX-3DM KCX-4D KCX-4DM KCX-5D KCX-5DM KCX-6D KCX-6DM KCX-B4 KCX-B4M KCX-B6 KCX-B6M KCX-3W KCX-4W KCX-4WM KCX-5W KCX-6W KCX-6WM KCX-B4W

More information

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters

KTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,

More information

TIMERS FOR ALL APPLICATIONS

TIMERS FOR ALL APPLICATIONS Timers Overview TIMERS FOR ALL APPLICATIONS AutomationDirect now offers solid-state timers brought to you by two leaders in the industry, FUJI and Koyo. FUJI Electric has been in business since 1923 and

More information

H7BX CSM_H7BX_DS_E_4_4

H7BX CSM_H7BX_DS_E_4_4 Multifunction Counter (DIN 72 72) H7BX CSM_H7BX_DS_E_4_4 DIN 72 72 mm Multifunction Counter with a Bright, Easy-to-view, Negative Transmissive LCD. Highly visible display with backlit transmissive LCD.

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m) All voltage photoelectric sensors Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only x x 7.4 mm. s with long life expectancy and high switching capacity

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR Built-in Power Supply Photoelectric Sensor CSM DS_E_12_3 Model Contribute to Overall Cost Reduction erminal Block Models Easy to wire and adjust. For the most recent information on models that have been

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Suitable for detecting transparent films or transparent bottles

Suitable for detecting transparent films or transparent bottles Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable 44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in

More information

Solid-State Counter/Timer

Solid-State Counter/Timer Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD display Present Value: 8 mm (0.32 in) Set Value: 4 mm (0.16

More information

H3CA-8H-AC/100/110/120

H3CA-8H-AC/100/110/120 Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat

More information

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure. Low-speed Monitoring Unit G9SX-LM Low-speed Monitoring Function Ensures Safety for Maintenance Work Motor rotation speed detected by Proximity Sensor. Monitors and confirms that speed does not exceed the

More information

DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard.

DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard. Multifunction Counter/Tachometer (DIN 48 48) H7CX Series CSM_H7CX_DS_E_2_1 DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative Transmissive LCD. The H7CX Defines a New Standard.

More information

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety Compact for High-Density Mounting with Easy Snap-In Connector H Connector features a built-in safety lock for shock and vibration resistance H replacement made simple without rewiring H Cables can be bent

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT

G60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT LINE SEIKI G0 SERIES ELECTRONIC P COUNTER or DIGITS ( Line LED Display) POWER SUPPLY (AC0 ~ 0V) PRESCALE FUNCTION KEY PROTECT, MEMORY DECIMAL POINT POSITIONING DUST / SPLASH PROOF G0 - G0 - MODEL SELECTION

More information

0DQXDO.& &9 6 6 & 3UHVHWWLQJ FRXQWHUV FACTORY AUTOMATION

0DQXDO.& &9 6 6 & 3UHVHWWLQJ FRXQWHUV FACTORY AUTOMATION FACTORY AUTOMATI :LWKÃUHJDUGÃWRÃWKHÃVXSSO\ÃRIÃSURGXFWVÃWKHÃFXUUHQWÃLVVXHÃRIÃWKHÃIROORZLQJÃGRFXPHQWÃLVÃDSSOLFDEOH 7KHÃ*HQHUDOÃ7HUPVÃRIÃ'HOLYHU\ÃIRUÃ3URGXFWVÃDQGÃ6HUYLFHVÃRIÃWKHÃ(OHFWULFDOÃ,QGXVWU\ÃDVÃSXEOLVKHGÃE\Ã

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in 1 Ultra-small Micro Photoelectric PM- SERIES Related Information General terms and conditions... F-17 Glossary of terms / General precautions... P.19~ / P.10 Amplifier Built-in selection guide... P.1~

More information

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs 19 Ultra-small Micro Photoelectric Sensor PM- SERIES Related Information General terms and conditions...p.1 Glossary of terms / General precautions...p.98~ / P.98~ Amplifier Built-in Sensor selection guide...p.11~

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_1 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.

More information

PRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition.

PRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition. PRESE HOUR MEER Hour Meter FEAURES 1. Preset function equipped in half size (24 48 mm.94 1.89 inch). 2. Display has backlight for instant recognition. ime counting iming up Red or (Green) (backlight) 3.

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display Digital Timer 1/16 DIN, Quartz Timer with Four-Digit LED Display Five wide ranges to choose from Wide-range AC or DC supply voltages Elapsed time (UP) or time remaining (DOWN) display available Selectable

More information

2. Actuator B: Ball type P: Pin type F: Flat type

2. Actuator B: Ball type P: Pin type F: Flat type Contact Displacement Sensor Built-in Amplifier Ensures Ease of Use and Saves Wiring Effort. Sensor Operates with a Low Force in a Wide Range of Applications. H Works with a low operating force (30 gf)

More information

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.

GL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost. 811 Compact & ow Price Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.176~ guide... P.781~ General precautions... P.179~ PHOTO PHOTO MEASURE

More information

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately) Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs. DIN SIZE DIGIAL IMER imers Compact Easy-to-read Easy-to-use... A digital timer made to meet the market s needs. Pin type Product types Part names terminal type Features. Bright and Easy-to-Read Display

More information

BGS (at min. setting) BGS (at max. setting)

BGS (at min. setting) BGS (at max. setting) Compact Photoelectric Sensor with Built-in Amplifier EZ-LS CSM_EZ-LS_DS_E_7_ Distance-settable Sensor Unaffected by Workpiece Color and Background Distance-settable triangulation model unaffected by color.

More information

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs 1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector

More information

SYSMAC Remote Transistor Module

SYSMAC Remote Transistor Module 9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

Long-distance Photoelectric Sensor with Built-in Amplifier. Connection method Sensing distance. --- Retro-reflective. (500 mm) Terminal block ---

Long-distance Photoelectric Sensor with Built-in Amplifier. Connection method Sensing distance. --- Retro-reflective. (500 mm) Terminal block --- Long-distance Photoelectric Sensor with Built-in Amplifier EG CSM_EG_DS_E_ _ Line of Long-distance Photoelectric Sensors for Large Workpieces Includes Retroreflective Models with Sensing Distance of m

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series 3 (For )/ 3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display Can be integrated with a vacuum unit, Series ZX Built-in

More information

Solid-state Timer H3YN

Solid-state Timer H3YN Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple

More information

Multifunction Counter/Tachometer H7CX Series

Multifunction Counter/Tachometer H7CX Series Multifunction Counter/Tachometer H7CX Series Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where

More information

DIN 48 SIZE LCD ELECTRONIC COUNTER. UL File No.: E C-UL File No.: E122222

DIN 48 SIZE LCD ELECTRONIC COUNTER. UL File No.: E C-UL File No.: E122222 C Counters -digit display -digit display..9 mm inch DIN SIZE CD EECTRIC U File No.: E C-U File No.: E Features. Bright and Easy-to-Read Display A brand new bright -color backlight CD display. The easy-to-read

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) EE-SX9 CSM_EE-SX9_DS_E Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs

More information

Zelio Count - Counters RC87610

Zelio Count - Counters RC87610 Zelio Count - Counters RC87610 Catalog March 05 Class 9051 CONTENTS Description..............................................Page Product Description........................................... RC87610050

More information

Self-Powered Counters H7EC

Self-Powered Counters H7EC Self-Powered Counters Subminiature Count Totalizers Require No External Power Supply Subminiature 8 x mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available AC, DC, and no-voltage

More information

Chapter. In This Chapter...

Chapter. In This Chapter... Getting Started Chapter In This Chapter... Manual Overview.... - Purpose of this Manual.... - Technical Support... - Special Symbols.... - General Description.... -3 Unpacking.........................................................

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

E2Q4 Square Proximity Sensor

E2Q4 Square Proximity Sensor Inductive Square Slim, compact size M2 Plug-in connection Integrated short circuit and reverse polarity protection Active face positioning: Y-axis 5, X-axis 90 incremets Ordering Information DC type Connection

More information

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30 Sensing distance Supply voltage Output 4 mm 8 mm 12 to 24 VDC 100 to 220 VAC 200 ma max. 100 ma max. Proximity Sensor Detects Objects without Being Influenced by Aluminum and Cast Iron Cut Chips Sense

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features Super Manual Fiber Amplifier Adjuster type standard that is the culmination of true ease and simplicity Features Self-explanatory LED bar displays of light levels The previous manual type used the stability

More information

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC Solid-state er DIN-sized (48 x 48 mm) Solid-state er with Timer Functions Easier operation due to improved front panel er and timer function modes switch-selectable Large easy-to-read 6-digit LCD Non-significant

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Separate Construction with Cylindrical 16-dia. Body Miniature design of 28.5 mm, the smallest class in the industry. Detachable

More information

SERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology.

SERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology. FX-11 SERIES FX-11 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology. Presenting a product which satisfies professionals using volume control. Besides

More information

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren Solid-state Power OFF-delay Timer II DIN 22.5-mm Solid-state Power OFF-delay Timer High immunity to invertor noise. Long power OFF-delay times; S-series: up to 12 seconds, L-series: up to 120 seconds.

More information

Compact Inductive Proximity Sensor

Compact Inductive Proximity Sensor SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter

More information

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output Solid-state Timer H3FA Please read and understand this catalog before purchasing the products. Please consult OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display. NEW product No, NPPDF 6-01E-3 Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure

More information

Terminal block 2 A 5 X 3. Specification

Terminal block 2 A 5 X 3. Specification D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables

More information

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m Through-Beam Sensor with Visible Red LED Visible Beam Allows Visual Confirmation of the Detection Spot, for Easy Installation and Maintenance Built-in amplifier Mutual interference protection filter included

More information

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available

GX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available 8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

EtherCAT Remote I/O Terminal GX series

EtherCAT Remote I/O Terminal GX series EtherCAT Remote I/O Terminal GX series Digital I/O Terminal 2-tier Terminal Block Type Digital I/O Terminal 3-tier Terminal Block Type Digital I/O Terminal e-con Connector Type Analog I/O Terminal 2-tier

More information

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price G-8/8U GA-/GH GX GX-U/FU

More information

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 8 PHOTO PHOTO MEASURE Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F- Glossary of terms... P.576~ panasonic.net/id/pidsx/global guide... P.78~ General

More information

Timer, Counter & Display

Timer, Counter & Display Timer, Counter & Display Quick Selection Guide Category Front Panel Size Pin Type Mounting Type Model No. Counter/Timer Dual use 72X72 - Flush mounting type KCT-72 72X36 - Flush mounting type KCT-DP Counter

More information

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability 82 PHOTO PHOTO Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.86~ Sensor selection guide... P.757~ General precautions...

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes. 1123 PHOTO PHOTO PARTICUR Type Edge Sensor SERIES Related Information General terms and conditions... F-3 About laser beam... P.1593~ guide... P.1021~ General precautions... P.1595 Conforming to FDA regulations

More information

Transistor I/O Link Modules

Transistor I/O Link Modules 9 Transistor I/O Link Modules Reduce Wiring Back to PLC Rack for 32 I/O Points 1 Transmit 16 input signals over just 2 wires (3 wires if only one terminal has a power supply) 1 Normal I/O delay (19.2 ms

More information

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50

Tachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50 List of content page Counters and indicators DA5-IU-C... 10 DA5-IU-2K-C... 12 DA5-IU-2K-V... 12 KCM-51-C... 14 KCM-51-V... 14 KCM-70-C... 16 KCM-70-V... 16 KCM-70A-C... 18 KCM-70A-V... 18 KCT-6S-C... 20

More information

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display. NEW product No, NPPDF 6-01E Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure

More information

BWPK Series. Picking sensor. Features. Specifications

BWPK Series. Picking sensor. Features. Specifications Picking Features Plastic injection case Slim body(w0 H T0mm) Long/Short sensing distance mode (sensing distance selection function) Mutual interference prevention(frequency switching function) Selectable

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I PRCM Series Cylindrical Connector Type Proximity Sensor Features Improved the noise immunity with dedicated IC Built-in reverse polarity protection circuit (DC -wire type) Built-in surge protection circuit

More information

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price GA-/GH GX GX-U/FU

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004 Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle.

Digital Counter H7CZ. Easy to Use and Easy to Read. Features. Basic Features Better Readability Character Height of 10 mm with a Wide Viewing Angle. Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-6 32 Ph: +91 44 4353 8888 Fax: 44 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com New Product Digital Counter

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information