1 Multichannel User Interface MI Instruction Manual Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

2 General safety considerations Always power off the Multichannel user interface MI before accessing the modules behind the display. K-Patents recommends the installation of an external power switch. Warning! If this device is used against manufacturer s instructions, user safety may be compromised. Warranty All K-Patents products are guaranteed to be free of material or workmanship defects. K-Patents provides a limited warranty that covers the repair or replacement, without charge, of any defected product or part that occurs within two (2) years from the date of delivery. The repair can only be done by nearest authorized K-Patents repair facility. Warranty does not cover normal wear and tear of the product over time, or any products that are handled, installed or used against manufacturer s guidance. Full warranty information is available in the Support section of Please note that prior to shipping any products or items to K-Patents, a Request for Return Materials Authorization (RMA) must be filled in and submitted to K-Patents Order Handling department. The RMA form is available at in the Support section. Disposal When wishing to dispose of an obsolete instrument or any parts of an instrument, please observe local and national regulations and requirements for the disposal of electrical and electronic equipment. Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

3 Symbols and terms used in this manual: This indicates a warning. It provides safety precaution information needed to avoid injury while operating the refractometer system. This indicates that something is important for the operation of the refractometer system. Note. Notes contain additional information and hints. Copyright K-Patents All rights reserved.

4 Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

5 Table of contents 1 Description Mounting Connections Connecting the power cable Power terminals for AC power Power terminals for DC power External mains switch Refractometer connections Ethernet connection Module cards Use Main display Troubleshooting main display Managing users and passwords Diagnostics display Viewing and adjusting parameters Refractometer verification Collecting field sample points Modules Mounting Configuration Relay module ma output module ma input module General I/O module Specifications A EU declaration of conformity B Software licence

6 MI instruction manual Command selection tree for measurement Command selection tree for settings Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

7 1 Description 1 1 Description The Multichannel user interface MI is an industrial computer designed to add functionality to the PR-43 refractometers. The MI sends and receives data and it can also be used to control the process. The Multichannel user interface MI connects with up to 4 K-Patents PR-43 refractometers. With module cards, it can also be used to add external inputs and outputs (e.g. relays and ma outputs) to your refractometer system. The MI is operated by the touch-screen display. The stainless steel enclosure gives a good environmental protection and allows also outdoor installations, especially with the included rain cover. The outer door is easy to open by one hand and the handle can be modified for padlock to prevent unauthorized access. The module cards can be reached by opening the inner door. The MI has IP66 rating when the outer door is open if the inner door (display panel) is fixed. With outer door closed the rating is IP67. Figure 1.1 Multichannel user interface MI Copyright K-Patents All rights reserved.

8 2 MI instruction manual 2 Mounting The Multichannel user interface MI can be mounted on a wall with wall mounting or on a table with a table stand. The mounting location should be easily accessible. If mounted outdoors, the MI has to be protected from rain and direct sunlight. Display on eye-level 1-4 refractometers External mains switch Ethernet 4-20 ma VAC Figure 2.1 Mounting guide Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

9 2 Mounting 3 Figure 2.2 Enclosure dimensions Copyright K-Patents All rights reserved.

10 4 MI instruction manual for refractometers Figure 2.3 Enclosure dimensions Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

11 2 Mounting mm (12.8 inches) mm (10 inches) 1. Bracket screwed to wall by 4 screws. Screw hole dimensions 325x254mm Figure Mounting the wall bracket Four mounting screws loosely attached Figure Top screws inserted into top bracket verticalmounting slots 3. Lower screws slide into bottom bracket horizontal mounting slots Mounting the MI onto the wall bracket 3 4. Tighten mounting screws x4 width a 19 mm ring spanner Note: Be careful when mounting, the MI weighs 13 kilos (28.5 lbs). Copyright K-Patents All rights reserved.

12 6 MI instruction manual Important: Do not drill mounting holes in the enclosure as that will affect the protection class of the enclosure and damage the electronics. The MI is shipped with a rain cover. K-Patents recommends that it is installed even indoors to protect the top of the door from dust and dirt Screw out top attaching screws to allow clearance for rain cover to slot in place Figure 2.6 The table stand is very simple to mount. Mounting the rain cover 2. Retighten screws Figure 2.7 Table stand Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

13 2 Mounting 7 The MI door handle can be modified to make space for a padlock to prevent unauthorized access. Remove handle center cover and remove segment indicated by break-line on the back of cover Replace center cover once indicated segment has been removed, making sure the opening aligns with the channel for the padlock shackle Figure 2.8 Locking the MI Copyright K-Patents All rights reserved.

14 8 MI instruction manual 3 Connections non-ex M12-8 pin, A-code, F+M max. 90m (295ft) M Multichannel user interface, MI 1 x M12-4 pin, D-code, F (External Ethernet) 4 x M12-8 pin, A-code, F (System) 1 x M12-4 pin, A-code, M (24VDC, ma) VAC or 24VDC PR-8440 Ethernet cable for interfaces M12-4 pin, D-code, M+M Ethernet M OR max. 90m (295ft) PR-8330 Ethernet cable for interfaces M12-4 pin, D-code, M+RJ45 Ethernet M M max. 90m (295ft) RJ45 OR ma cable max. 200m (656ft) Figure 3.1 Multichannel user interface connections Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

15 3 Connections Connecting the power cable Warning! Make sure there is no power in your cable. Then open the enclosure and the inner door. You need a TX25 screw driver to open the inner door retaining screws Figure Push door gently 2. Lift handle 45 deg up 3. Open the door Opening the enclosure Remove inner door retaining screws and open inner door Figure 3.3 Opening the inner door Unscrew one of the cable glands and push the power cable through. Connect the power cable to the power terminals at lower right of the motherboard (see below). Screw on the cable gland. Close the inner door and turn power on Power terminals for AC power The primary AC power is connected to a separate terminal strip 1/2/3 in the lower right-hand corner of the motherboard. The three terminals are marked 1.L, 2.N and 3 (protective earth). The power terminal 3/PE is directly connected to the exposed metal parts of the MI. Wiring to the terminals shall be 1.5mm 2 minimum. The protective fuse in the building system shall comply with the local requirements. Copyright K-Patents All rights reserved.

16 10 MI instruction manual 1.L 2.N 3 Figure 3.4 AC power terminals on the motherboard Power terminals for DC power The DC power is connected to a terminal stripe in the lower right-hand corner of the motherboard. The three terminals are marked 1+, 2- and 3 (protective earth). The power terminal is directly connected to the exposed metal parts of the MI. The 24V DC power to this terminal stripe shall be supplied from a secondary circuit which is double or reinforced insulated from the mains supply within the limits for a limitedenergy circuit (maximum 200 VA/U) according to the IEC External mains switch External mains switch Figure 3.5 Installing external main switch Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

17 3 Connections 11 Important: The MI does not have a built-in power switch. The system is always powered when connected to a power source. K-Patents recommends mounting an external mains switch to control the MI s power supply (Figure 3.5). The external power switch should be easy to access. It is also recommended to use a 10A/230V circuit breaker for power supply. MULTI CHANNEL USER INTERFACE MI INSTRUMENTS M12 CONNECTORS MAIN POWER SWITCH PR L N N POWER SUPPLY VAC/50-60Hz ma Output mA L - + ETHERNET M12-4pin, D-code, M PR-8440 Ethernet cable for interfaces 4158 MI has 8 module slots. Any of module cards can be installed into any free slot. There could be multiple module cards in slots depending on external I/O needs. + OPTIONAL 24V POWER SUPPLY FOR MI VDC ETHERNET M12-4pin, D-code, M - PR ma output module PR Relay output module PR ma output module PR Relay output module x PR UN/AX/IA refractometer (For Intrinsic refractometer see further wiring drawing 4118) x SAFETY SWITCH PR-7060 PR-8430 Platform 4 cable N L L L L N x SOLENOID VALVE FOR PNEUMATICALLY OPERATED SHUT-OFF VALVE ASSEMBLY: PR /110/240 SLOT 2 SLOT 4 SLOT 6 SLOT 8 SLOT 1 SLOT 3 SLOT 5 SLOT 7 Grounding screw x N x POWER SUPPLY VAC/50-60Hz or 24VDC L 1 N L Figure 3.6 Multichannel user interface wiring Copyright K-Patents All rights reserved.

18 12 MI instruction manual 3.2 Refractometer connections The refractometers are connected to the MI with a M12 male-female 8 pins A-coded cable PR-8430, maximum length 90 m. The refractometer connectors are located underneath the MI enclosure as a group of four. Refractometer connections can be made while the MI is powered. A refractometer can be connected to any of the four connectors. 3.3 Ethernet connection The leftmost connector underneath the MI is for ethernet output. It is for a M12 male 4-pins D-coded cable. The cable can be connected while the MI is powered. If you wish to connect the MI with e.g. a laptop, K-Patents offers an interconnecting cable PR-8330 with a 12-pin connector in one end and a RJ-45 connector in the other end. 3.4 Module cards For the installation of the module cards, see Chapter 5 Modules. Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

19 4 Use 13 4 Use Power up the Multichannel user interface MI. A startup display with a progress bar is shown for approximately one minute, then the Main display appears. The MI is operated by tapping the touch screen. To get access to the MI touch screen, open the enclosure door. Note: If you find that the touch screen is difficult to use with fingers, try tapping it with e.g. the blunt end of a pen or use a fingernail instead of the whole fingertip. The screen works even when you are wearing gloves. 4.1 Main display The main view can show up to four application windows at the same time. You can access measurement data and system settings via the Main display. Tap anywhere in the application window to access measurement Tap to access system settings Figure 4.1 Accessing measurement and system settings via Main display The Main display setup is controlled via Settings > General. Display mode and display language are chosen in drop-down menus, tap the little triangle to see the whole menu. If you only have one application (usually a single refractometer), One maximized will make the most of the display. Dual vertical allows you to see two application, Quadrant and One on top shows up to of four applications at the same time. Note: If you have three applications and choose One maximized, you ll only see one application, but the other two will continue to run in the background. Copyright K-Patents All rights reserved.

20 14 MI instruction manual Display mode Display language Figure 4.2 Selecting display mode and display language Figure 4.3 Setting "One maximized" Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

21 4 Use 15 Figure 4.4 Setting "Dual vertical" Figure 4.5 Setting "Quadrant" Copyright K-Patents All rights reserved.

22 16 MI instruction manual Figure 4.6 Setting "One on top" Note: If the MI is left with a different display, e.g. Calibration, it will automatically go back to the Main display after a timeout. Note: You can adjust the refractometer application to show concentration only, temperature only or both concentration and temperature. To change this setting, tap on the application window (see Figure 4.1) and choose Calibration (You may need to enter your password to get access to Calibration display). Then select the preferable display mode. Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

23 4 Use 17 Figure 4.7 Calibration display Troubleshooting main display The Main display may be empty even when one or several refractometers are connected to the MI. Copyright K-Patents All rights reserved.

24 18 MI instruction manual Figure 4.8 Empty main display in quadrant mode This means that one or several applications must be activated. Go to Settings > Applications, tap on the correct application slot and select the app for that slot. Figure 4.9 Selecting an application Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

25 4 Use Managing users and passwords Some functions and settings, e.g. calibration, require a user to log in. Most functions in the settings, including user management, are only available to the master user. The master user password (pin code) is printed on the delivery data sheet shipped with the MI. Go to Settings > Users to manage users. K-Patents recommends that a user name and a password is set separately for each user who needs to have frequent access to the restricted functions. Figure 4.10 The Users display Tap + Add User to add users. Tap Set name to get access to the keyboard, then type the username and tap OK. Note: If you have entered a username, you must enter a password, too, you cannot leave the password field empty. To remove a user, go to Users and tap the name of the user you want to remove, then tap Remove user. Note: The MI can store up to 38 users. Copyright K-Patents All rights reserved.

26 20 MI instruction manual Figure 4.11 Writing a username Figure 4.12 New user added to the list 4.3 Diagnostics display Tap the application window to access the Diagnostics display. In the top part of the window you see the optical and slope curves. By default both optical image and slope Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

27 4 Use 21 are shown, but you can tap on the texts OPTICAL and SLOPE to turn these on and off. Figure 4.13 Diagnostics display The tabs in the lower part of the display contain detailed information about the measurement. Tap the name of the tab to see the contents. Input tab shows the values as sent by the refractometer. Output tab shows the results of the calculations by MI. Identification tab contains various identification information and e.g. software version information. Support tab is a summary of the information in the other tabs and other information needed by technical support for troubleshooting. Figure 4.14 Input tab Figure 4.15 Output tab Copyright K-Patents All rights reserved.

28 22 MI instruction manual Figure 4.16 Identification tab Figure 4.17 Support tab Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

29 4 Use Viewing and adjusting parameters To view the parameters, go to the Calibration display and tap on Summary. Note that the summary extends to a second page, a small arrow on the top right will take you to the second (and third) page. To adjust the parameters, go to the Calibration display, then choose appropriate parameter set, eg. Field. In the list, tap the parameter you want to change, type the new numbers with the number pad and approve the change by tapping DONE. Note: The parameter lists for Chemical and Field do not fit on the screen. Swipe down or use the scroll bar on the right to view the bottommost parameters. Figure 4.18 Calibration display The settings in the upper part of the Calibration display are different types of lists that sets parameters for showing the measurement data, e.g. measurement unit. In the lower part of the window, the words are links to the given settings, e.g. by tapping on Field you get access to the field calibration parameters. If you want to see all the parameters, tap Summary. Copyright K-Patents All rights reserved.

30 24 MI instruction manual Figure 4.19 First page of calibration summary (tap the little arrow in top right to see page 2) Figure 4.20 Second page of calibration summary (tap the little arrow in top right to see page 3) Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

31 4 Use Refractometer verification An offline refractometer can be verified with standard refractive index liquids, available from K-Patents. Depending on the refractometer model, a sample holder may be needed. Go to the Diagnostics display (see Figure 4.13) and choose Verification. If you are not familiar with the verification procedure, tap the question mark on the Verification display for additional instructions. Figure 4.21 Verification in process Once you have finished the verification process, you can save the verification results as pdf. The pdf is stored in the MI memory and it can be downloaded over the ethernet connection. Each pdf report gets a unique name and thus you can have several verification pdfs in the MI at the same time. Copyright K-Patents All rights reserved.

32 26 MI instruction manual Figure 4.22 Finished verification Figure 4.23 Pdf saved Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

33 4 Use Collecting field sample points You can use the field sample functionality to acquire data points for K-Patents field calibration service. Go to the Diagnostics display (see Figure 4.13) and tap Field sample. Figure 4.24 Field sample display Figure 4.25 Field sampling in process Copyright K-Patents All rights reserved.

34 28 MI instruction manual Figure 4.26 Collected field sample points Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

35 5 Modules 29 5 Modules The modules add functionality to the MI e.g. ma output and relays. Each module is installed in a card slot inside the MI. There are slots for for 8 modules. Note: The MI is shipped with a relay module and a ma output module. These are already installed in your MI. In addition to the relay module PR (2 relays) and ma output module PR (2 x 4-20 ma), an ma input module PR (2 x 4-20 ma) and a PR general i/o module are available. 5.1 Mounting To install a module turn off MI power first. Then open the enclosure, remove the display screws and fold the display out of the way (see Figure 5.1). Unscrew and remove the module card cover to get access to the card slots. Insert the module in an available card slot. K-Patents recommends for safety reasons that relay modules are mounted in slots 2,4,6 and 8 (connector downwards). Other module cards may be mounted in any slot. Important: A relay module may have an external power source. Make sure that the relay module power is also off before installing or removing module cards. Copyright K-Patents All rights reserved.

36 30 MI instruction manual Remove inner door screws and open inner door Remove 4 screw holding the module holder and remove module holder Figure 5.1 Insert new module in the first left free module holder. 1, 3, 5, 7 modules are connector upwards and 2, 4,6, 8 are connector downwards. Inserting a module card Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

37 Modules 31 To make the connections, first remove the removable connector from the module card. Bring the module connection cable to the MI and put it through the cable gland (1). Then connect wires to the screw terminals on the removable connector (2), see the module-specific sections for further information. Finally reconnect the removable connector to the module card (3) MI-010 Figure 5.2 Connecting module connection cable to module card 5.2 Configuration The MI automatically finds the installed module(s). To configure a module, got to Settings > Modules, tap the module slot and then View module to access module configuration. Copyright K-Patents All rights reserved.

38 32 MI instruction manual 5.3 Relay module The PR relay module adds two relays to the Multichannel user interface MI. The relays can be configured independently to any connected refractometer. The relays can be used e.g. for controlling prism wash. Specifications Relays per module 2 Voltage and current rating Connection Connector Contact type Normal relay state Max. 250V/3A Screw connection with tension sleeve Phoenix MC 1,5/ 7-ST1-5,08 Dry contact NO Conductor cross section flexible min mm 2 Conductor cross section flexible max. 1.5 mm 2 Conductor cross section AWG min. 28 Conductor cross section AWG max. 16 Stripping length Tightening torque, min. Tightening torque, max. 7 mm (¼") 0.22 Nm 0.25 Nm Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

39 5 Modules 33 LED RLY2 LED RLY1 7 Relay 1+ 6 Relay 1-5 Relay 2+ 4 Relay 2-3 no connection 2 no connection 1 no connection Figure 5.3 Relay connections 5.4 ma output module The ma output module adds ma outputs to Multichannel user interface MI. On the module card there are two independent 4-20 ma current sources. Both current outputs are configurable independently to indicate for example process concentration or temperature or other diagnostic data of any connected refractometer. A ma output has traceable calibration, accuracy is ±0.02 ma. Maximum load (compliance) is 1000 Ohm. There is a place inside the Multichannel user interface MI where the cable shield can be connected for grounding. Cable specifications Conductor cross section flexible min mm 2 Conductor cross section flexible max. 1.5 mm 2 Conductor cross section AWG min. 28 Conductor cross section AWG max. 16 Tightening torque, min. Tightening torque, max Nm 0.25 Nm Copyright K-Patents All rights reserved.

40 34 MI instruction manual 10 ma out 1+ 9 ma out 1-8 no connection 7 no connection 6 ma out 2+ 5 ma out 2-4 no connection 3 no connection 2 Frame ground 1 Frame ground Figure 5.4 ma output pinout The ma outputs are compliant to Namur NE43. NAMUR NE 43 uses the 3.8 to 20.5 ma signal range for measurement information, with 21 ma or 3.6 ma to indicate diagnostic failures (see Figure 5.5). With that information, it is easier to detect a failure condition on a refractometer, for example, it clearly tells you if you have an empty pipe. failure Figure 5.5 Measurement Data OK Default ma output values failure ma Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

41 5 Modules 35 Certain malfunctions cause the ma measurements to return to ma default output value, see Table 5.1 below. Factory setting for default output value is 3.4 ma. Returns to default ma Message Conc Temp Short-circuit X X No optical image Temp measurement fault X X No sample Prism coated Connection lost X X Table 5.1 Messages causing ma output value to return to default output X X X 5.5 ma input module The ma input module adds two analog inputs to Multichannel user interface MI. Specifications Two independent ±20 ma analog inputs 24-bit resolution 6 samples/s sample rate Traceable calibration Screw-terminal connectivity Galvanic isolation 1000 VDC or AC (peak) Table 5.2 ma input module specifications The ma inputs are compliant to Namur NE43. NAMUR NE 43 uses the 3.8 to 20.5 ma signal range for measurement information, with 21 ma or 3.6 ma to indicate diagnostic failures (see Figure 5.5). With that information, it is easier to detect a failure condition. Copyright K-Patents All rights reserved.

42 36 MI instruction manual failure Measurement Data OK Figure 5.6 Default ma output values failure ma Terminal no. Description Function 1 ma1+ ma-in 1+ 2 ma1- ma-in 1-3 Not connected Not in use 4 Not connected Not in use 5 ma2+ ma-in 2+ 6 ma2- ma-in 2-7 Not connected Not in use 8 Not connected Not in use 9 Frame ground Not in use 10 Frame ground Not in use Figure 5.7 ma input pinout Cable specifications Conductor cross section flexible min mm 2 Conductor cross section flexible max. 1.5 mm 2 Conductor cross section AWG min. 28 Conductor cross section AWG max. 16 Tightening torque, min Nm Tightening torque, max Nm Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

43 5 Modules General I/O module The General I/O module adds digital inputs and outputs to Multichannel user interface MI. The module has 4 digital inputs, 4 digital outputs, GND and +3.3 V. The input and output terminals are galvanically isolated according to UL 2500 V rms (UL1577) CSA 800 V rms (1131V peak) maximum working voltage - basic insulation CSA 400 V rms (566V peak) maximum working voltage - reinforced insulation VDE Reinforced insulation 560V peak TüV Reinforced insulation 400V rms maximum working voltage Cable specifications Conductor cross section flexible min mm 2 Conductor cross section flexible max. 1.5 mm 2 Conductor cross section AWG min. 28 Conductor cross section AWG max. 16 Tightening torque, min. Tightening torque, max Nm 0.25 Nm Digital inputs: Use the 3.3 V output (pin 10) for digital inputs. See Figure There is a 3 kohm pull down resistance on every input. Digital outputs: Use the GND (pin 9) for digital outputs. See Figure 5.9. There is a 1 kohm series resistance on every output. Copyright K-Patents All rights reserved.

44 38 MI instruction manual Digital input characteristics Level Min Max Input voltage 0V 3.3 Input low voltage V Input high voltage 1.5 V - Input low current (Vin=0V) ma Input high current (Vin=3.3V) ma Digital output characteristics Level Min Typ Max Low-level output current (I ) ma High-level output current (I ) - - 3mA Output low voltage (V ), 100 A - 0V - at 0.5 ma - 0V - at 1 ma - 0V - at 3 ma - 0V - Output high voltage (V ), -100 A V - at -0.5 ma V - at -1 ma V - at -3 ma V - Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

45 5 Modules 39 Terminal no. Description Function 1 Digital output Out 1 2 Digital output Out 2 3 Digital output Out 3 4 Digital output Out 4 5 Digital input In 5 6 Digital input In 6 7 Digital input In 7 8 Digital input In 8 9 Ground for outputs GND VDC for inputs Figure 5.8 I/O module pinout Terminal No. Description F 1 Digital input 1 I 2 Digital input 2 I 3 Digital input 3 I 4 Digital input 4 I 5 Digital output 1 O 6 Digital output 2 O 7 Digital output 3 O 8 Digital output 4 O 9 Ground for outputs G VDC for inputs N Copyright K-Patents All rights reserved.

46 40 MI instruction manual PR Digital outputs Digital inputs GND 3.3 VDC Figure 5.9 Digital output connections PR Digital outputs Digital inputs GND 3.3 VDC Figure 5.10 Digital input connections Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

47 5 Modules 41 The digital outputs can be configured for Concentration - high limit Concentration - low limit Error Full wash Normal Precondition Temperature - high limit Temperature - low limit Warning Wash The digital inputs can be configured for External hold External wash External wash stop Copyright K-Patents All rights reserved.

48 42 MI instruction manual 6 Specifications Model: Multichannel User Interface Product code: MI-M-UN-AC S/N: MI00103 Tag: V AC, 50/60 Hz, 60 VA Made by K-PATENTS Oy, Vantaa, Finland C US IP67 Type 4x Model: Multichannel User Interface Product code: MI-M-UN-DC S/N: MI00103 Tag: 24V DC, 60 W Made by K-PATENTS Oy, Vantaa, Finland C US IP67 Type 4x V AC 24 V DC Figure 6.1 MI nameplates Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

49 6 Specifications 43 MI specifications Display: Power: Overvoltage category: Refractometer connectivity: Ethernet connection: Modules: Apps: Protection class: Installation: Weight: Regulatory compliance: xga 1024 x 768 pixels, touch screen AC input VAC, ±10%, 50/60 Hz, 60 VA, optional 24 VDC OVC II 1-4 refractometers can be connected to the MI. Refractometers independent of each other: own parameter sets and usable in different applications. 10/100 Mbit/s, data acquisition over UDP/IP Protocol 1-8 modules for added connectivity 1-4 apps Enclosure IP66/67. Type 4X with outer door open, type 6, 12, 13 with outer door closed, also 6P with outer door locked with a padlock Indoor/outdoor, max. 50 C (122 F), min. 0 C (32 F), must be protected from rain and direct sunlight.during installation highest relative humidity of ambient air 80%. Highest altitude 2000 m above sea level kg (28.5 lbs) Safety: IEC :2010/EN :2010, CSA certified to CSA-C.22.2 No , UL :2012 Electromagnetic compatibility: IEC :2012/EN :2013. Optional modules Relay Module: ma Output Module: Regulatory compliance 2 signal relays 150V/3A 2 x 4-10mA, max. load 1000 Ohm, galvanic isolation 1000VDC Safety: IEC :2010/EN :2010, CSA certified to CSA-C.22.2 No , UL :2012 Electromagnetic compatibility: IEC :2012/EN :2013 Copyright K-Patents All rights reserved.

50 44 MI instruction manual Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

51 A EU declaration of conformity 45 A EU declaration of conformity Copyright K-Patents All rights reserved.

52 46 MI instruction manual Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

53 B Software licence 47 B Software licence This software includes parts of software libraries included under the following licence notices. Copyright 2012, Aaron Gifford All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. Neither the name of the <organization> nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL AARON GIFFORD BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Copyright K-Patents All rights reserved.

54 48 MI instruction manual Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

55 Command selection tree for measurement 49 Command selection tree for measurement Main screen APPLICATION DIAGNOSTICS CALIBRATION TREND LOG PRISM WASH VERIFICATION FIELD SAMPLE INPUT OUTPUT IDENTIFICATION SUPPORT SELECT DISPLAY MODES PRIMARY UNIT PRIMARY DECIMALS SECONDARY UNIT CHEMICAL FIELD TAG SENSOR SOURCES PRISM WASH SUMMARY CLEAR CONCENTRATION TEMPERATURE BOTH CELSIUS FAHRENHEIT Copyright K-Patents All rights reserved.

56 50 MI instruction manual Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

57 Command selection tree for settings 51 Command selection tree for settings Main screen SETTINGS GENERAL DISPLAY SETUP QUADRANT SCREEN BRIGHTNESS LANGUAGE HIGH CONTRAST MODE ONE ON TOP DUAL VERTICAL ONE MAXIMIZED Master user login required (IP address can be viewed without login) NETWORK Refractometer DATE & TIME PROTECT WITH PASSWORD BACKUP/RESTORE FACTORY RESET UPDATE SYSTEM TAG CURRENT IP ADDRESS IP ADDRESS MODE SET STATIC IP ADDRESS SET SUBNET MASK SET FIRST SENSOR IP ADDRESS STATIC DYNAMIC AUTO YES START BOOTP SERVER NO CURRENT IP ADDRESS AUTO Ethernet IP ADDRESS MODE SET STATIC IP ADDRESS SET SUBNET MASK SET DEFAULT GATEWAY STATIC DYNAMIC AUTO APPLICATIONS APP SLOT X (1-4) MODULES MODULE SLOT X (1-8) ADD REMOVE USERS ADD USER SET NAME LOG CLEAR SET PASSWORD Copyright K-Patents All rights reserved.

58 52 MI instruction manual Document/Revision No. IM-EN-MI/1.02 Effective: November 17, 2016

59

60 K-Patents Oy P.O. Box 77 FI Vantaa, Finland tel fax K-Patents, Inc Centre Point Circle, Suite 106 Naperville, IL 60653, USA tel. (630) fax (630) K-Patents (Shanghai) Co., Ltd Room 1509, Tomson Commercial Building, No.710 Dongfang RD Pudong District, Shanghai, China tel /0598 fax

Remote Divert User Interface DI. Instruction Manual

Remote Divert User Interface DI. Instruction Manual Remote Divert User Interface DI Instruction Manual Document/Revision No. IM-EN-DI: Rev. 1.05 Effective: August 15, 2017 General safety considerations Always power off the Remote divert user interface DI

More information

FC-11 FIELD COMMUNICATOR 1.54 INSTRUCTION MANUAL. IM-EN-FC11 Version 1.13

FC-11 FIELD COMMUNICATOR 1.54 INSTRUCTION MANUAL. IM-EN-FC11 Version 1.13 FC-11 FIELD COMMUNICATOR 1.54 INSTRUCTION MANUAL IM-EN-FC11 Version 1.13 Table of contents 1 Description............................................................ 1 1.1 Kit contents....................................................

More information

FLAMEBOSS 300 MANUAL

FLAMEBOSS 300 MANUAL FLAMEBOSS 300 MANUAL Version 2.1 Download latest at FlameBoss.com/manuals WARNING: Important Safety Instructions It is important for the safety of persons to follow these instructions. Save these instructions.

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

HouseLink HL-10E Installation and Operation Manual Modbus TCP

HouseLink HL-10E Installation and Operation Manual Modbus TCP HouseLink HL-10E Installation and Operation Manual Modbus TCP HouseLink HL-10E 7/12/2016 Table of Contents Installation Overview... 3 Components... 3 BinTrac Indicator... 3 Load Cell Bracket... 3 Smart

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Bosch Smart Home. Plug Instruction Manual

Bosch Smart Home. Plug Instruction Manual Bosch Smart Home Plug Instruction Manual Start making your home smart! Please be sure to install the Bosch Smart Home Controller first. Please ensure that you have a Bosch Smart Home Controller and the

More information

FLAME BOSS 200V2 & 300 MANUAL. Version 2.6 Download latest at FlameBoss.com/manuals

FLAME BOSS 200V2 & 300 MANUAL. Version 2.6 Download latest at FlameBoss.com/manuals FLAME BOSS 200V2 & 300 MANUAL Version 2.6 Download latest at FlameBoss.com/manuals WARNING: Important Safety Instructions It is important for the safety of persons to follow these instructions. Save these

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

HouseLink HL-10E. Installation and Operation Manual Modbus TCP and XML

HouseLink HL-10E. Installation and Operation Manual Modbus TCP and XML HouseLink HL-10E Installation and Operation Manual Modbus TCP and XML HouseLink HL-10E 4/25/2018 Table of Contents Installation Overview... 3 Components... 3 BinTrac Indicator... 3 Load Cell Bracket...

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

The identified danger could cause physical and property damage.

The identified danger could cause physical and property damage. Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor

More information

Anybus Wireless Bridge Ethernet Bluetooth Access Point Product Guide

Anybus Wireless Bridge Ethernet Bluetooth Access Point Product Guide Anybus Wireless Bridge Ethernet Bluetooth Access Point Product Guide Document Revision Document number: 1 Release: November 21, 2014 Document version: 1 General This document is a product guide defining

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

Vision OPLC V TR6/V350-J-TR6

Vision OPLC V TR6/V350-J-TR6 Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)

More information

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

OPLC Installation Guide

OPLC Installation Guide Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs

More information

Digital ac/dc (24V) Input Module

Digital ac/dc (24V) Input Module Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

SD1306. Speed Dome IP Camera. Quick User Guide

SD1306. Speed Dome IP Camera. Quick User Guide SD1306 Speed Dome IP Camera Quick User Guide Table of Contents I. Camera Introduction... 1 1. Package Contents... 1 2. Hardware Installation... 2 2.1 Factory Default... 6 3. SD card Compatibility List...

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

BACnet/IP Web Interface

BACnet/IP Web Interface Desigo Control Point BACnet/IP Web Interface PXG3.W100-1, PXG3.W200-1 Web-based, graphical operation of BACnet automation stations using Desigo touch panels and devices with an HTML 5.0 web browser. Simultaneous

More information

Model Number: DZ300-12EU

Model Number: DZ300-12EU Model Number: DZ300-12EU Data Sheet Revision A February 2007 www.optimal-power.com i PROPRIETARY DATA All data in this datasheet is proprietary and may not be disclosed, duplicated or used for procurement

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

This guide provides basic information for Unitronics controller model V T2.

This guide provides basic information for Unitronics controller model V T2. Vision OPLC 12 pnp/npn Digital, including 2 Analog, 3 HSC/Shaftencoder Inputs, 12 Transistor Outputs This guide provides basic information for Unitronics controller model V350-35-T2. General Description

More information

ABB Drives. User s Manual I/O Module Adapter AIMA-01

ABB Drives. User s Manual I/O Module Adapter AIMA-01 ABB Drives User s Manual I/O Module Adapter AIMA-01 I/O Module Adapter AIMA-01 User s Manual 3AFE 64661442 REV A EN EFFECTIVE: 1.12.2003 2003 ABB Oy. All Rights Reserved. 5 Safety instructions Overview

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01

Ethernet to J1939 Installation Guide AB7665. Part no. SP0863 Rev. 1.01 Anybus X-gateway Ethernet to J1939 Installation Guide AB7665 Part no. SP0863 Rev. 1.01 HMS Industrial Networks AB Germany Japan Sweden U.S.A. France Italy China + 49-721 - 96472-0 + 81-45 - 478-5340 +

More information

87421/22A Power Supply. Operating and Service Manual

87421/22A Power Supply. Operating and Service Manual 87421/22A Power Supply Operating and Service Manual Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998 Notice The information contained in this document is subject to

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All

More information

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01 ABB Drives User s Manual Digital I/O Extension Module RDIO-01 Digital I/O Extension Module RDIO-01 User s Manual 3AFE 64485733 REV B EN EFFECTIVE: 10.2.2003 2003 ABB Oy. All Rights Reserved. Safety Instructions

More information

Multi Unit Enclosed Meter

Multi Unit Enclosed Meter Contents Description Page Introduction Preliminary comments and safety precautions............................... 2 Warranty and liability information................ 2 Safety precautions..............................

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

Nokeval. FD100 series. User Manual

Nokeval. FD100 series. User Manual Nokeval FD100 series User Manual Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device

More information

Vision OPLC. V T38 Installation Guide. General Description

Vision OPLC. V T38 Installation Guide. General Description Vision OPLC V130-33-T38 Installation Guide The Unitronics V130-33-T38 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 2 HSC/Shaft-encoder Inputs 16

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

Signal Doublers. VariTrans A 20300

Signal Doublers. VariTrans A 20300 ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

Custom Controller Installation Instructions

Custom Controller Installation Instructions MODEL CUSTOM CONTROLLER HARDWARE CODE MAX ALLOWABLE AMBIENT TEMP: 70 C (158 F) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1) THIS DEVICE MAY

More information

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G) Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches Installation Guide P/N 5500339-10 (Rev G) Overview This document contains instructions necessary for the installation and operation of the Perle IDS-108F

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ. Vision OPLC V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ. General Description V1210 OPLCs are programmable logic controllers that comprise a built-in operating

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). Vision OPLC Installation Guide Models V230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens). General Description Vision OPLCs

More information

PGR-3200 MANUAL INSULATION MONITOR

PGR-3200 MANUAL INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN

More information

High Speed Remote I/O Module

High Speed Remote I/O Module High Speed Remote I/O Module EXF-RC15 The Unitronics EXF-RC15 is a High Speed Remote I/O Module that offers three High Speed Counter inputs and four high speed outputs. Overall, the EXF-RC15 offers 9 digital

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

PSA200 User s Manual

PSA200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

This guide provides basic information for Unitronics controllers V C30B and V T40B.

This guide provides basic information for Unitronics controllers V C30B and V T40B. Vision OPLC V570-57-C30B and V570-57-T40B (Color) This guide provides basic information for Unitronics controllers V570-57-C30B and V570-57-T40B. General Description Vision OPLCs are programmable logic

More information

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006 s SIWAREX JB Aluminum Housing Instruction Manual Edition 03/2006 Table of Contents Table of Contents... 2 Warning and Safety Terms... 3 General... 4 1 Technical Description... 5 1.1 Area of Application...

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors Installation and Operation Manual BTU-4D/BTU-4D-I Installation and Operation Manual Rev E Table of Contents Introduction... 1 TEMP OUTDOOR Sensor... 1

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B PMDX-103 Parallel Port Isolator Board User s Manual Date: 20 February 2007 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

ICS Entrance Management Sign Installation Guide. Version 1.0

ICS Entrance Management Sign Installation Guide. Version 1.0 ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-10M Protection Switch January 2009 Rev O ALARMS MENU OUTPUT = CH1 AUTO POWER 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 CH2 REMOTE EXECUTE Data, drawings, and other

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

TBX-1316 High-Voltage Attenuator Terminal Block

TBX-1316 High-Voltage Attenuator Terminal Block INSTALLATION GUIDE TBX-1316 High-Voltage Attenuator Terminal Block This guide describes how to install and use the TBX-1316 high-voltage attenuator terminal block with the following modules: SCXI-1125

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Rev. 1 September 2012 Part No. 4417551 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15

More information

Ground Master Monitor Installation, Operation and Maintenance

Ground Master Monitor Installation, Operation and Maintenance USER GUIDE TB-9078 Ground Master Monitor Installation, Operation and Maintenance Made in the United States of America The Ground Master Monitor and its accessories are available as the following item numbers:

More information

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35LM33MW liquid level control relay RM35-L V AC/DC Characteristics liquid level control relay RM35-L - 24..240 V AC/DC Complementary reset time maximum switching voltage Main range of product product or component type relay type relay name relay monitored

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server

1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server WARRANTY REGISTRATION: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual 1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server

More information

InCos-P Pressure sensor 20 Pa Pa

InCos-P Pressure sensor 20 Pa Pa InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.

More information

Q4X Stainless Steel Analog Laser Sensor

Q4X Stainless Steel Analog Laser Sensor Quick Start Guide Class laser CMOS analog sensor with an analog output. Patent pending. This guide is designed to help you set up and install the Q4X Analog Sensor. For complete information on programming,

More information

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-12s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-12s 8-Relay expansion module is used with the X-600M controller. The X-12s has eight

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

TRC-190 User s Manual

TRC-190 User s Manual First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement

More information