and installation instructions Power Converter DLU 02

Size: px
Start display at page:

Download "and installation instructions Power Converter DLU 02"

Transcription

1 Always read te operating and installation instructions before start-up! Work on automatic burner control systems may only be carried out by trained specialist personnel! Operating and installation instructions Power Converter DLU 02 Never carry out work wen a voltage is present! Tis is also important wen excanging or installing lowvoltage components suc as servo motors, displays or communications components. Ceck te functioning of te device if fuses are defective. Only trained specialist personnel may set te operating parameters. Te communication connection may only be used in conjunction wit te approved components. Te in-pase connection and te protective conductor connection sall be carried out in accordance wit te wiring diagram and cecked before start-up. Tampering wit te electronics or inappropriate storage renders te device warranty null and void. Te automatic burner control system is specified wit te entries made ere and no features are guaranteed. If tese instructions are not observed, damage to persons or property may occur. Description Microprocessor-controlled power converter for adapting controllers or DDC systems wit power or current interfaces (0-10 V, 4-20 ma) to ebus-compatible automatic burner control systems of te MPA series. Te device converts analogue power control signals from an external controller or DDC system into standard ebus messages and converts ebus information sent by te automatic burner control systems into analogue power or current signals. Accessories AM02 display ebus connecting cable (4-wire, 400 mm) Order data Type DLU 02 Order No DLU AM 02 Display 1 16

2 Table of contents Overview... 3 Installation and operation instructions... 4 Tecnical data Application and setting instructions... 7 Display and operating unit... 8 Display and operating unit - info display Display and operating unit - parameterising mode

3 Overview DLU 02 Dungs power converter for coupling controllers and DDC systems wit ebus-compatible automatic burner control systems Te Dungs DLU 02 power converter as te following functions: Microprocessor-based electronics Installation in ousing to IP20 Connection system wit RAST 5 and RAST 2.5 plug-in connectors 24 VDC/25 ma power supply for powering external current level converters Selectable input for power actuator signals eiter as voltage input of V/ V or as current input of ma/ ma V/ V output ma/ ma output Integrated ebus connection Four-wire ebus connection (TTL level) for connecting automatic burner control systems witout fully integrated ebus connection Connection for external display unit for instrument parameterising Voltage/current input Input for controlling te modulation of a connected MPA series automatic burner control system using ebus. 100 % 50 % 0 % Modulation dept 0 V 0/4 ma 5 V 0/4 ma Hysteresis Input 10 V 0/4 ma Te voltage input converts te V voltage to a modulation dept of % and sends tis via te ebus to a connected automatic burner control system. Te voltage input can be used as a current input by placing a jumper between terminals 8 and 9. Tis current input can be switced from ma to ma using a software switc. Negligible canges to te input parameter are not transmitted immediately. Canges wic are smaller tan te ysteresis (+/- 5 % of te end value) are transmitted after one minute. Scematic Diagram Regulator Analogue control variable V, ma or ma Analogue return signal V, ma or ma Automatic burner control system ebus Mains DLU 02 power converter Voltage/current input Te DLU 02 supplies te modulation dept sent by te MPA as an analogue output variable. A modulation dept of 100 % (10 V) means 100 % power wereas a modulation dept of 0 % (0 V) indicates tat burner is running at minimum power. Te modulation dept can be measured as a current signal ( ma) using te current output. Tis output can be adjusted to ma using a software switc. As te output signals of te voltage and current outputs are internally linked, te voltage output also switces from V to V. Power supply output Tere is a power supply of 24 VDC for powering external modules (suc as level converters). Tis supply as a load capacity of max. 25 ma. ebus interface Te DLU 02 as a fully-functional ebus interface. An ebus supply wit a constant current of 20 ma and SYN caracter generator are integrated. Display ebus PC adapter Oter ebussubscriber PC wit MPA-Vision MV5 Four-wire ebus connection To connect te DLU 02 to automatic burner control systems wic are only equipped wit a four-wire ebus interface (e.g. MPA22), te DLU 02 is also fitted wit suc an interface. Bot devices can be interconnected using a special connecting cable witout te need for a special MPA/ ebus adapter. Connection for external display unit Te DLU 02 is parameterised using an external display unit wic is not required for operation. Te display unit is a special accessory. Alternatively, you ave te option of parameterising te DLU02 wit MPA-Vision. 3 16

4 Installation and Operation Instructions Installation You can install te device in any position. Electrical connection Always carry out connection and protective grounding in accordance wit te local regulations and te wiring diagram. Fuses External fusing of te DLU02 wit a 6.3A max. slow-blow fuse. If a fuse is faulty, ceck te functioning of te device! Wiring diagram Start-up Te device must be de-energised before installation or maintenance work is carried out. Only trained specialist personnel may set te operating parameters. Te communication connections and te connection to te display and operating unit may only be used in conjunction wit te approved components. Always carry out te in-pase connection in accordance wit te wiring diagram and ceck on start-up. Do not connect te current output wit GND! Performance during faults If tere is a communication fault, measure te ebus supply. Te functionality of te ebus system can be establised using a simple ebus tester or using a laptop and te MPA-Vision software. If tese installation and operation instructions are not followed, damage to persons or property may occur. Terefore always comply wit te instructions. Tampering wit te electronics renders te warranty null and void. 4 16

5 Tecnical Data Nominal voltage ~(AC) 230 V 15 % + 10 % [ V ] Frequency 50 Hz [ Hz] Performance rating ~ 8 VA [ V A] [ A ] MPA IEC 529 ϒC Fuses Protection type Ambient 0 C + 60 C temperature Humidity DIN Back-up fuse, max. 6.3A, slow-blow IP20, IP40 must be ensured by installation IEC 529 (DIN ) DIN PE kg [kg] Electrical Coded plug system RAST 5 and RAST 2.5 connection Wiring must be executed in accordance wit local regulations and te wiring diagram. Extra-low voltage is isolated. Protective groundconnection Weigt None 0,45 kg 5 16

6 Tecnical data Voltages and currents Communications Dimensions: Voltage input Current input Voltage output ebus 0/ V Input resistance = 4.75 kω 0/4...2 ma Input resistance = 500 Ω 0/ V Load <= 500 Ω Do not connect te output to GND! 4-wire isolated 2-wire wit 20 ma constant current source Output power Cable lengt max. 2m 24 VDC, max. 25 ma To ebus specifications Layer 1/2: V1.0 Layer 7: V1.2 PC service program MPA-Vision for Windows 95 Connection using ebus-pc interface 48 63, ,2 14,2 78 4,2Ø

7 Application and Setting Instructions Setting te voltage and current input You can define weter te input is to be used as a voltage or current input using terminals 8 and 9. If te connections stay open, te input will function as a voltage input. If tere is a jumper between tem, te input functions as a current input. Te use and te voltage or current range is selected using parameters nos. 3 & 4. Parameter No. P03 Analogue input OFF ON Deactivated Activated Parameter No. P04 Jumper Input OFF No V ON No V OFF Yes ma ON Yes ma Settings of te voltage and current input Te use and te voltage or current range of te two outputs is selected using parameters nos. 5 & 6. Parameter No. P05 OFF ON Analogue output Deactivated Activated Parameter No. P06 Voltage output Current output OFF V ma ON V ma Setting te communications addresses Te DLU02 possesses two parameters for setting te ebus addresses. Parameter no. 1 returns te ebus address of te DLU, and is preconfigured to te address 10H. Parameter no. 2 is te ebus address of te connected automatic burner control systems. Te standard address for tis is 03H. Important for use wit te MPA automatic burner control system MPA for te software versions up to V2.23 expects te ebus address of 10H as te address of te DLU, wic means tat parameter 1 must be set to tis value. Also, MPA sends te current performance and not te modulation dept to te DLU because of te older ebus specifications. 7 16

8 Display and Operating Unit Operating te display Te display and operating unit is principally only required for te parameterising of te DLU 02. If te display is connected, te device switces to operating display mode after switc-on and te execution of system tests. Only te text DLU 02 is output. Using specific key combinations, you can switc te device to info display mode or parameter display mode. Te individual modes are described below. Switc-on System tests Operating display Press for approx. 0.5 secs. + Press for approx. 2 secs. Info display Parameter display 8 16

9 Display and Operating Unit Info display Info display Te information display can only be reaced via te operation display. It gives information on te software version, te software date, te device number, te production date, te DLU ebus address, te MPA ebus address, te analogue input status, te analogue input offset, te analogue output status, te analogue output offset and te cycle time for modulation dept request. After 20 seconds, te device exits tis display and eiter times out or switces to te previous display. Info display Press for approx. 0.5 secs., until symbol i appears. Ten release key. Info display 0 Information on DLU software version Info display 1 Information on te DLU software date (DDMMYY) 1 2 Info display 2 Information on te device number 9 16

10 Display and Operating Unit Info display 1 2 Info display 3 Information on te production date Info display 4 Information on te DLU ebus address in exadecimal caracters Info display 5 Information on te MPA ebus address in exadecimal caracters 3 4 Info display 6 Analogue input status OFF = Analogue input deactivated ON = Analogue input active 10 16

11 Display and Operating Unit Info display 3 4 Info display 7 Analogue input offset OFF = ma or V ON = ma or V Info display 8 Analogue output status OFF = Analogue output deactivated ON = Analogue output active Info display 9 Analogue input offset OFF = ma or V ON = ma or V Back to operating display 11 16

12 Display and Operating Unit Parameterising mode Parameterising mode Te Parameterising mode provides te facility of displaying important operating parameters and setting tem wit te keyboard. Wen adjusting te settings in Parameterising mode, set te access level to 3 (Service) so tat all te parameters in te Service level can be set in MPA-Vision. After 20 seconds, te device exits tis display and eiter times out or switces to te previous display. Wen you exit te parameter display, te device automatically restarts to update te canged parameters. Parameterising display + Press for approx. 2 secs. until P00 appears 1 2 Enter te access level for EEPROM. It is set automatically on entry to Level 3 (Service). approx. 20 secs. wit restart Press te keys in tis order and old tem down for approx. 2 secs. -> Access Level 2 (OEM) is activated. witout restart approx 0.2 secs

13 Display and Operating Unit Parameterising mode 1 2 ca. 0,2 s + + approx. 20 secs. wit restart Cange te ebus address using te + and - keys approx. 20 secs. wit restart Cange te ebus address using te + and - keys Displays te DLU s ebus communication address Displays te MPA s ebus communication address

14 Display and Operating Unit Parameterising mode approx. 20 secs. wit restart Cange te switc using te + and - keys. Te + key switces to ON and te - key switces to OFF. approx. 20 secs. wit restart Cange te switc using te + and - keys Te + key switces to ON and te - key switces to OFF. Analogue input status OFF = inactive ON = active Analogue input OFF = ma, or V ON = ma, or V

15 Display and Operating Unit Parameterising mode approx. 20 secs. wit restart Cange te switc using te + and - keys. Te + key switces to ON and te - key switces to OFF. approx. 20 secs. wit restart Cange te switc using te + and - keys Te + key switces to ON and te - key switces to OFF. Analogue output status OFF = deactivated ON = active Analogue output OFF = ma, or V ON = ma, or V Restart Back to operating display 15 16

16 We reserve te rigt to make any canges in te interest of tecnical progress. Head Offices and Factory Karl Dungs GmbH & Co. KG Siemensstraße 6-10 D Urbac, Germany Telepone +49 (0) Fax +49 (0) Postal address Karl Dungs GmbH & Co. KG Postfac D Scorndorf, Germany Internet

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML 11.20 DMA 40 P 230/02 3 L DMA 30 P 230/03 0 L DMA 30 Q 230/10 0 L DMA 30 A 230/10 0 L Printed in Germany Edition 08.14 Nr.

More information

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML

DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML DMA Actuator drives for - Motorised Butterfly Valve DMK - Motorised throttle DML 11.20 DMA 40 P 230/02 3 L DMA 30 P 230/03 0 L DMA 30 Q 230/ 0 L DMA 30 A 230/ 0 L Printed in Germany Edition 02. Nr. 229

More information

ISOMETER isopv with coupling device AGH-PV

ISOMETER isopv with coupling device AGH-PV Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling

More information

Section 2.3: Calculating Limits using the Limit Laws

Section 2.3: Calculating Limits using the Limit Laws Section 2.3: Calculating Limits using te Limit Laws In previous sections, we used graps and numerics to approimate te value of a it if it eists. Te problem wit tis owever is tat it does not always give

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

2.8 The derivative as a function

2.8 The derivative as a function CHAPTER 2. LIMITS 56 2.8 Te derivative as a function Definition. Te derivative of f(x) istefunction f (x) defined as follows f f(x + ) f(x) (x). 0 Note: tis differs from te definition in section 2.7 in

More information

each node in the tree, the difference in height of its two subtrees is at the most p. AVL tree is a BST that is height-balanced-1-tree.

each node in the tree, the difference in height of its two subtrees is at the most p. AVL tree is a BST that is height-balanced-1-tree. Data Structures CSC212 1 AVL Trees A binary tree is a eigt-balanced-p-tree if for eac node in te tree, te difference in eigt of its two subtrees is at te most p. AVL tree is a BST tat is eigt-balanced-tree.

More information

PLK-B SERIES Technical Manual (USA Version) CLICK HERE FOR CONTENTS

PLK-B SERIES Technical Manual (USA Version) CLICK HERE FOR CONTENTS PLK-B SERIES Technical Manual (USA Version) CLICK ERE FOR CONTENTS CONTROL BOX PANEL MOST COMMONLY USED FUNCTIONS INITIAL READING OF SYSTEM SOFTWARE/PAGES 1-2 RE-INSTALLATION OF TE SYSTEM SOFTWARE/PAGES

More information

More on Functions and Their Graphs

More on Functions and Their Graphs More on Functions and Teir Graps Difference Quotient ( + ) ( ) f a f a is known as te difference quotient and is used exclusively wit functions. Te objective to keep in mind is to factor te appearing in

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

5S3, MIR & MEC OEM OEM Communications Protocol Manual

5S3, MIR & MEC OEM OEM Communications Protocol Manual OEM Communications Protocol Manual Analox Limited 15 Ellerbeck Court, Stokesley Business Park, Nort orksire, TS9 5PT, UK UK/RoW T: +44 (0)1642 711400 F: +44 (0)1642 713900 US T: (714) 891-4478 W: www.analox.net

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

M2TECH EVO SUPPLY LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL

M2TECH EVO SUPPLY LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL M2TECH EVO SUPPLY USER MANUAL REV. PRD 8/2012 Warning! Canges or modifications not autorized by te manufacturer can invalidate te compliance to CE regulations and cause te unit to be no more suitable to

More information

Motorised Butterfly Valve DMK Nominal Diameter Rp 3/4 - Rp 2

Motorised Butterfly Valve DMK Nominal Diameter Rp 3/4 - Rp 2 Motorised Butterfly Valve DMK Nominal Diameter Rp / - Rp.0 Printed in Germany Rösler Druck Edition 0.0 Nr. 9 77 Technical description The DUNGS DMK motorised butterfly valve is an actuator without zero

More information

VersaPoint I/O Module

VersaPoint I/O Module Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

Old documentation - Only for your information! Product is not available anymore!

Old documentation - Only for your information! Product is not available anymore! Double solenoid valve Control and safety combination valve Servo pressure controller - / 7. Printed in Germany Rösler Druck Edition 0.08 Nr. 09 8 Technical description The DUNGS multiple actuator DMV-SE...

More information

Haar Transform CS 430 Denbigh Starkey

Haar Transform CS 430 Denbigh Starkey Haar Transform CS Denbig Starkey. Background. Computing te transform. Restoring te original image from te transform 7. Producing te transform matrix 8 5. Using Haar for lossless compression 6. Using Haar

More information

Safety Temperature Limiter TT-STL 50

Safety Temperature Limiter TT-STL 50 GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Safety Temperature

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

JUMO dtrans T02. programmable. transmitter. B Operating Instructions 5.00/

JUMO dtrans T02. programmable. transmitter. B Operating Instructions 5.00/ JUMO dtrans T02 programmable transmitter B 95.6521 Operating Instructions 5.00/00380664 Overview of operation JUMO dtrans T02 Standard accessory 1 Type designation (1) Basic version 956521 programmable

More information

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7 M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320

More information

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

SD1. Differential Controller. Operating and Installation Instructions F2 72.3 SD1 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

I/O module, universal, digital, S0 inputs, modu533

I/O module, universal, digital, S0 inputs, modu533 Product data sheet 5.1 92.046 EY-IO 533: I/O module, universal, digital, S0 inputs, modu533 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features Part of

More information

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 125

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 125 Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN - DN 7. Printed in Germany Rösler Druck Edition 0.0 Nr. Technical Description The DUNGS multiple

More information

Process displays For current and voltage

Process displays For current and voltage Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma

More information

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies.   Key Features: MPU-120S Series Single, 180W Compact, U-Channel AC/DC Power Supplies Key Features: 180W Power Universal 90-264 AC Power Factor Correction EN 60950 Approved Compact U-Channel Five Single Models Meets EN

More information

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with

More information

Fast Calculation of Thermodynamic Properties of Water and Steam in Process Modelling using Spline Interpolation

Fast Calculation of Thermodynamic Properties of Water and Steam in Process Modelling using Spline Interpolation P R E P R N T CPWS XV Berlin, September 8, 008 Fast Calculation of Termodynamic Properties of Water and Steam in Process Modelling using Spline nterpolation Mattias Kunick a, Hans-Joacim Kretzscmar a,

More information

Compact pressure switch for multiple actuators

Compact pressure switch for multiple actuators Comct pressure switch for multiple actuators GW A GW A/.0 Printed in Germany Edition 0.0 Nr. 90 Technical description The GW A pressure switch is a comct pressure switch as r EN 8 for DUNGS multiple actuators.

More information

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar Plug-in module SIRAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SIRAX TV 808 (Fig. ) is to electrically insulate

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS VERSION 1.7 npi 2015 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230;

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

PHOENIX CONTACT - 01/2007

PHOENIX CONTACT - 01/2007 Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

Notes: Dimensional Analysis / Conversions

Notes: Dimensional Analysis / Conversions Wat is a unit system? A unit system is a metod of taking a measurement. Simple as tat. We ave units for distance, time, temperature, pressure, energy, mass, and many more. Wy is it important to ave a standard?

More information

Neon pr. ph/ ORP measurement. Applications. Description

Neon pr. ph/ ORP measurement. Applications. Description Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment

More information

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

PSR UC/ESAM4/3X1/1X2/B

PSR UC/ESAM4/3X1/1X2/B Safety relay for emergency stop and safety door monitoring Data sheet 105318_en_02 PHOENIX CONTACT 2014-06-13 1 Description The safety relay can be used in safety circuits according to EN 60240-1 and IEC

More information

ISOMETER isoev425 with coupling device AGH420

ISOMETER isoev425 with coupling device AGH420 with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device

More information

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter Click on Series name for product info on aimtec.com Models Single output Model Input Voltage (VAC/Hz) FEATURES: Input Voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum

More information

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter FEATURES: Click on Series name for product info on aimtec.com Series AME-JZ I/O Isolation 000VAC Low Ripple and Noise Operating Temp: -0 C to +70 C Over Voltage Protection Over current Protection Up to

More information

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06 PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

, 1 1, A complex fraction is a quotient of rational expressions (including their sums) that result

, 1 1, A complex fraction is a quotient of rational expressions (including their sums) that result RT. Complex Fractions Wen working wit algebraic expressions, sometimes we come across needing to simplify expressions like tese: xx 9 xx +, xx + xx + xx, yy xx + xx + +, aa Simplifying Complex Fractions

More information

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 100

Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 65 - DN 100 Double solenoid valve Combined pressure regulator and safety valves Servo pressure regulator MBC-...-SE DN 5 - DN 00 7. Printed in Germany Edition 0. Nr. Technical Description The DUNGS multiple actuator

More information

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER FEATURES 120W medical adapter with active PFC Green power CEC/Energy star group complied Designed to meet medical standard type BF rated Conductive EMI meets CISPR/FCC class B Wall mount mechanical construction

More information

PHOENIX CONTACT Features

PHOENIX CONTACT Features Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase

More information

J itron DR 100 Microprocessor Controller

J itron DR 100 Microprocessor Controller JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 60030 Fax: +49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net

More information

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3 INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page

More information

VOLUMES. The volume of a cylinder is determined by multiplying the cross sectional area by the height. r h V. a) 10 mm 25 mm.

VOLUMES. The volume of a cylinder is determined by multiplying the cross sectional area by the height. r h V. a) 10 mm 25 mm. OLUME OF A CYLINDER OLUMES Te volume of a cylinder is determined by multiplying te cross sectional area by te eigt. r Were: = volume r = radius = eigt Exercise 1 Complete te table ( =.14) r a) 10 mm 5

More information

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter Operating Instructions PRO-AB Leakage Current Measuring Adapter 3-349-621-15 3/6.15 Table of Contents Page 1 Scope of delivery...2 2 Safety Precautions...2 3 General...3 4 Preparing for Measurement...4

More information

Series S202/SX202 Large size displays for panel mounting

Series S202/SX202 Large size displays for panel mounting Series S202/SX202 Large size displays for panel mounting Visible over long distances Te presentation of information over long distances, te visualisation of process data, Remote indication of measured

More information

M2TECH HIFACE DAC 384KHZ/32BIT DIGITAL-TO-ANALOG CONVERTER USER MANUAL

M2TECH HIFACE DAC 384KHZ/32BIT DIGITAL-TO-ANALOG CONVERTER USER MANUAL M2TECH HIFACE DAC 384KHZ/32BIT DIGITAL-TO-ANALOG CONVERTER USER MANUAL REV. 1.1 5/2013 Warning! Canges or modifications not autorized by te manufacturer can invalidate te compliance to CE regulations and

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES DS 13.321 BAS 2800+ 06/99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER Specification no. 579-1-904 The Universal Network Controller (UNC 596) is fully intelligent and incorporates its

More information

ASI QUINT /2.4 EFD

ASI QUINT /2.4 EFD Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678

More information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown depends on

More information

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies.   Key Features: MPO-120S Series Single, 180W Compact, Open Frame AC/DC Power Supplies Key Features: 180W Power Universal 90-264 AC Power Factor Correction EN 60950 Approved High Efficiency Five Single Models Meets EN

More information

I/O module, digital and universal inputs, modu530

I/O module, digital and universal inputs, modu530 Product data sheet 92.031 EY-IO 530: I/O module, digital and universal inputs, modu530 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features Part of the

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

Motorised Butterfly Valve DMK

Motorised Butterfly Valve DMK Motorised Butterfly Valve DMK Nominal Diameter Rp / - Rp. DMK...-Q DMK...-P Printed in Germany Edition. Nr. 9 77 Technical description The DUNGS DMK motorised butterfly valve is an actuator without zero

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline analog input terminal, 4 inputs for connecting voltage signals Data sheet 8081_en_01_C01 PHOENIX CONTACT 2015-04-14 1 Description The terminal is designed for use within an Inline station. It is

More information

Piecewise Polynomial Interpolation, cont d

Piecewise Polynomial Interpolation, cont d Jim Lambers MAT 460/560 Fall Semester 2009-0 Lecture 2 Notes Tese notes correspond to Section 4 in te text Piecewise Polynomial Interpolation, cont d Constructing Cubic Splines, cont d Having determined

More information

Figure 1a. D-MAX WEB GUIDE CONTROLLER (D-Max 2 Dual Drive with Wall Mount Bracket Shown)

Figure 1a. D-MAX WEB GUIDE CONTROLLER (D-Max 2 Dual Drive with Wall Mount Bracket Shown) D-MAX WEB GUIDE CONTROLLER NOTE: All dimensions and specifications are in mm [inches] unless specified otherwise. Figure 1a. D-MAX WEB GUIDE CONTROLLER (D-Max 2 Dual Drive with Wall Mount Bracket Shown)

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. DALI gateway TW Art. No. : 2099REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property

More information

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers Power Supply for IT/ITN ULTRASTAB transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±10 V voltage output Six individual

More information

IB IL 24/48 DOR 2/W-XC-PAC

IB IL 24/48 DOR 2/W-XC-PAC Inline digital output terminal, version for extreme conditions, 2 relay PDTs Data sheet 8463_en_01 PHOENIX CONTACT 2015-08-12 1 Description The terminal is designed for use within an Inline station. It

More information

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09. T M 1 IRDH375 Series Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE101051 / 09.013 IRDH375 Series Digital ground fault monitor / ground detector

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

Materials: Whiteboard, TI-Nspire classroom set, quadratic tangents program, and a computer projector.

Materials: Whiteboard, TI-Nspire classroom set, quadratic tangents program, and a computer projector. Adam Clinc Lesson: Deriving te Derivative Grade Level: 12 t grade, Calculus I class Materials: Witeboard, TI-Nspire classroom set, quadratic tangents program, and a computer projector. Goals/Objectives:

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

MTH-112 Quiz 1 - Solutions

MTH-112 Quiz 1 - Solutions MTH- Quiz - Solutions Words in italics are for eplanation purposes onl (not necessar to write in te tests or. Determine weter te given relation is a function. Give te domain and range of te relation. {(,

More information

4.1 Tangent Lines. y 2 y 1 = y 2 y 1

4.1 Tangent Lines. y 2 y 1 = y 2 y 1 41 Tangent Lines Introduction Recall tat te slope of a line tells us ow fast te line rises or falls Given distinct points (x 1, y 1 ) and (x 2, y 2 ), te slope of te line troug tese two points is cange

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

3/4 U CPCI Serial Case System

3/4 U CPCI Serial Case System 3/4 U CPCI Serial Case System User s Manual Product Number: 4579-634 Doc-No: 6397-345_R.0 October 05 R.0 October 05 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt, Germany

More information

12.2 Techniques for Evaluating Limits

12.2 Techniques for Evaluating Limits 335_qd /4/5 :5 PM Page 863 Section Tecniques for Evaluating Limits 863 Tecniques for Evaluating Limits Wat ou sould learn Use te dividing out tecnique to evaluate its of functions Use te rationalizing

More information

Motorised butterfly valve DMK Nominal Diameters DN 40 to DN 125

Motorised butterfly valve DMK Nominal Diameters DN 40 to DN 125 Motorised butterfly valve DMK Nominal Diameters DN 40 to DN 125 11.11 DMK...-P DMK...-Q Printed in Germany Edition 01.18 Nr. 226 595 1 6 Technical description The DUNGS DMK... motorised butterfly valve

More information

Indicomp 4 Bargraph Indicator

Indicomp 4 Bargraph Indicator Data Sheet 10/30-2.16-EN Indicomp 4 Bargraph Indicator Display is optionally LCD active: self-luminuous green on black self-luminuous green on blue LCD passive: self-luminuous black on light grey 2 input

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter Click on Series name for product info on aimtec.com FEATURES: I/O Isolation 000V Continuous Short circuit protection Operating Temp: -2 C to 0 C Energy Star compliant Input: -26V, -6Hz, or 20-0VDC pact

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

MR52 READER INTERFACE

MR52 READER INTERFACE IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This

More information

Extension module for lighting control

Extension module for lighting control s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or

More information

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads Data sheet 709061 Page 1/21 JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads The JUMO TYA 201 represents a consistent further development of the JUMO power controller

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

1/1 FULL SIZE 3/4 QUARTER SIZE 1/2 HALF SIZE EXTRA LARGE SIZE EXTRA LONG SIZE

1/1 FULL SIZE 3/4 QUARTER SIZE 1/2 HALF SIZE EXTRA LARGE SIZE EXTRA LONG SIZE STERILE CONTAINER SYSTEMS BIO-BARRIER 1/1 FULL SIZE 3/4 QUARTER SIZE 1/2 HALF SIZE EXTRA LARGE SIZE EXTRA LONG SIZE Aygün Bio-Barrier model sterilization container systems are designed wit mecanical valves

More information

3.6 Directional Derivatives and the Gradient Vector

3.6 Directional Derivatives and the Gradient Vector 288 CHAPTER 3. FUNCTIONS OF SEVERAL VARIABLES 3.6 Directional Derivatives and te Gradient Vector 3.6.1 Functions of two Variables Directional Derivatives Let us first quickly review, one more time, te

More information