1 Daqstation DXAdvanced DX1000/DX2000 DX1000/DX2000 Bulletin 04L41B01-01E

2 Introducing DAQSTATION reaches a new dimension With unparalleled measurement, display, and connectivity functions, the new DXAdvanced data acquisition and display stations provide all-in-one data measurement, visualization and historian functions with no programming or costly integration. At the same time they can seamlessly integrate with your existing I/O and plant SCADA/ HMI systems. As the next generation DAQSTATION, DXAdvanced is built on years of field-proven performance with Yokogawa quality and reliability built-in. Basic Functions Up to 48 channels of input User can start/stop recording by batch, and create data files! Expandable to up to 348 channels with the MW100 automatic connection function Display & Operation Arrange the display your way with a custom display function! Review historical data with date and time calendar search functions Networking Standard Ethernet interface Supports the PROFIBUS-DP and EtherNet/IP protocols! Expanded Web and networking functions! Reliability and Security Dust- and splash-proof front panel (IP65, NEMA4 compliant) Highly reliable internal memory with error-correction function Front panel door lock and login function Application Software Software for a variety of tasks including analysis, settings, and acquisition DAQSTANDARD: Supports settings and data file analysis DAQStudio: Builder software for custom displays DAQWORX: Integrated Data Acquisition Software Suite DX1000 2

3 DX2000

4 Basic Functions Universal inputs, with multi-batch, high capacity recording Offers accuracy, long-duration, and scalability when acquiring data in the field. Plus, it enables asynchronous data acquisition by measurement group. Supports a wide variety of applications, offering greater added value. Multi-channel Measurement and Recording The DX1000 and the DX2000 provide up to 12 or 48 Universal input channels respectively, providing high performance standalone recording functions. It can be used in various applications as an easy to use, traditional paperless recorder. Multi-batch Function Record pre-defined channel groups to separate data files with independent start and stop control. You can create up to 6 (DX1000) or 12 (DX2000) batches. * Only 6 batches can be created on the DX2000 with the standard memory. Universal input supporting all types of inputs Batch1 Batch2 Batch3 Batch12 DC voltage, thermocouple, RTD, and digital output NO.1 NO.2 NO.3 NO.12 Up to 48 channels Run Stop Stop Run Up to 12 channels Batch12 DX1000 DX2000 Batch1 Scalable, High Input Capacity via External I/O Using Modbus TCP communications, Yokogawa s MW100 data acquisition platform and other vendor s I/O products can be the source of many additional input channels. In this manner, up to 240 external channels can be input to DXAdvanced. Using optional math channels, 60 additional external inputs can be acquired for a total of 300. Start small and scale up your system by adding additional MW100 input modules, as you need them. Modbus client DX channels built in (maximum) MW100 expansion 240 channels + 60 computation channels 348 channels total (maximum) Ethernet High Speed Measurement A new fast sampling mode on 2, 4, and 8 input DXAdvanced models provides a scan interval of 25 ms. All other models support a 125 ms scan speed in this mode. This capability allows all DXAdvanced models to capture and record fast-transient input signals. Model DX1002, DX1004 DX2004, DX2008 DX1006, DX1012 DX2010~DX2048 High-Speed Scan Interval (Fast sampling mode) High-Speed Scan Interval (Normal mode) 25 ms 125 ms 125 ms 1 s Fast sampling mode enables detailed acquisition of high-speed signals. Measured value MW100 Modbus server : Measurement at 25 ms (DXAdvanced) : Measurement at 125 ms (conventional models) Scan interval

5 High Capacity Internal Memory DXAdvanced supports up to 200 MB of non-volatile, internal flash memory. This secure, reliable memory can hold almost 3 years of data (30 channels at 1 minute sample rate), with capacity in reserve for any recording application. Internal memory size (MB) Media FIFO Function This function ensures that the CF card always retains the latest data when files are saved to it automatically. When the CF card is full, the oldest files are deleted to make room for the newest files. The media FIFO function allows you to use the DX continuously for long periods of time without having to change the CF card. Conventional model DXAdvanced (standard memory) DXAdvanced (large memory) Overview of the Media FIFO Function Old Update date New DXAdvanced (large memory) DXAdvanced (standard memory) Conventional model Deleted File 1 File 2 File 3 Saved File 4 * The maximum number of files that can be created in the internal memory is 400. Display data file sample time Measurement CH = 30 channels. Computation CH = 0 channels. Display update (minute/div) Save interval (s) Total sample time Save interval (s) Total sample time DX2000 (200 MB) 30 minutes 60 s Approx days Event data file sample time Measurement CH = 30 channels. Computation CH = 0 channels. DX2000 (200 MB) 1 s Approx. 34 days Medium Optional USB Flash Drive A USB flash drive can be used to transfer data to your PC. The optional front panel USB port also allows an external PC keyboard to be used with the DXAdvanced to facilitate setting and text entry. CompactFlash Removable Storage Media All DXAdvanced models include a CompactFlash drive. Rugged and readily available CompactFlash cards (CF cards) serve as the removable media, and are available as optional accessories. Up to 2 GB CF card supported.

6 Display & Operation New display modes and fast, easy-to-use data search functions Build custom display screens that provide a new level of flexible and informative data presentation. Operators benefit from new calendar history search functions. Customizable Display Screens! Custom Display Function Freely arrange elements of trends, bar graphs, and other screen components. You can also add bitmap images to make your overview monitors more intuitive. Offers new display functions that go beyond conventional recorders. Example: Concurrent placement of screens with different time axes. Long-duration trends and nearby high-speed monitor displayed simultaneously. Create more intuitive overview monitors by adding bitmaps. For example, you can customize a scale with an informative bitmap. Add any of the DXAdvanced components. DAQStudio (Available in February, 2009) Builder software lets you edit and create custom display screens on a PC. You can send and receive layout data, and easily edit and create objects. * DAQStudio sold separately.

7 Advanced Display and User Interface Flexible and Intuitive Display Modes All operation screens can be accessed using the operation keys. In addition, the Favorite key enables instant access to an operation screen that is selected in advance. Bar graph display Vertical or Horizontal bar graph can be selected in the bar graph display mode. Large-font digital display The digital display mode shows measured data as numeric values, and displays channel number, tag name, engineering units, and alarm status. Historical trend display This display mode allows you to display historical data stored in memory. Split screen display This mode lets you split the screen into four areas, and select the display format for each of the areas. Horizontally divided trend display Horizontally divides the trend display into two screens enabling waveform comparison of different channels. Information display This information screen displays alarm summary, message summery, memory information or media information. Overview display This screen lets you monitor the alarm status and numeric value for all channels. Integral bar graph When connecting to a flowmeter or power monitor, you can use bar graphs to check integrated values. Circular display In addition to the normal T-Y trend display, circular display is possible (DX2000 only). Alarm annunciator display Display detailed alarm information from each channel by degree of importance. You can also choose from three ISA alarm sequences of non lock-in, lock-in, and double lock-in.

8 DXAdvanced status display area This area graphically presents the DXAdvanced operating status. Trend display area This area displays Trend Lines, together with scale values and engineering units for each channel along with user selectable messages. Digital display area This area displays digital measurement values, together with channel or tag numbers, industrial units, and alarm statuses for each channel. Scale display area Scales the measured values of each channel. Color band, alarm mark, or bar graph can be displayed on the scale display. DX2000 Navigation keys The Navigation keys are used for functions such as switching display modes, primarily during normal operations (in operation mode). When entering settings, the Navigation keys are used to move the cursor. Favorite key Press the Favorite key to instantly switch to the display mode selected in advance. Key panel The key panel contains function keys, memory sampling START/STOP keys, and a numerical key pad (DX2000 only). These keys are primarily used to perform various actions related to data recording, and to enter settings in the DXAdvanced. DX1000 Display mode menu Press the DISP key in the operation keys to show a pop-up display mode menu. Then, simply select a menu using the operation keys to switch the display mode. Powerful New Data Search Tool! Search for historical data by date and time using the intuitive calendar display.

9 Networking Includes the latest networking technology Provides field data to the office or other connected devices in real time. Supports more highly advanced Web functions and network protocols such as PROFIBUS-DP and EtherNet/IP. Web Server Functions Easy monitoring from a Web browser DXAdvanced s Web server function provides easy monitoring via Internet Explorer or other Web browsers. Offers a very easy and low-cost remote/ broadband monitoring system. Input messages Input text messages to the DXAdvanced with a web browser. Search for data by date and time Easily search for and browse data stored in DXAdvanced by date/time over the Web. Display reports Using the Report function on DXAdvanced, you can display selected report channels and print reports in any format from a Web browser. Display alarm summary You can confirm alarm information on DXAdvanced from a Web browser. Display lists of data Files saved to the removable media or internal memory can be viewed and copied.

10 Networking Networking Functions [FTP data transfer] The FTP client function in the DXAdvanced will automatically transfer, at preset times, data files saved to the DXAdvanced unit's internal memory. Both a primary and secondary server can be specified. If a transfer to the primary server fails, files will automatically be transferred to the secondary server. FTP client function FTP server function FTP client [Time synchronization with network time servers] DXAdvanced uses SNTP protocol in client mode to acquire time information from a network time-server. This function allows any number of DXAdvanced units within a facility to have precisely synchronized time; all units will record data with coordinated date and time stamp information. In addition, DXAdvanced can function as a server, providing time data to other SNTP client units on the network. SNTP server Ethernet Service request Ethernet Time Sync Time Sync - Display data files - Event data files - Report files - Display image files Primary Secondary FTP servers Files on storage media, including: - Display data files - Event data files - Report files FTP server Ethernet Time Sync [Automatic network setup (DHCP) function] Using Dynamic Host Configuration Protocol (DHCP), the DXAdvanced can automatically acquire the settings it needs (IP address) for network communications from a DHCP server. This makes it easier than ever to install the unit on a plant network. DXAdvanced (SNTP client) PC (SNTP client) When the DXAdvanced is connected to a network, it automatically obtains network-setting parameters such as the IP address from a DHCP server. It also automatically registers the host name to a DNS server. DHCP/DNS server IP address, default gateway, DNS settings, etc. Automatically registers the host name LAN [ messaging function] The DXAdvanced can send a variety of informative messages that include alarm notification reports, periodic instantaneous data values, scheduled report data and other information. With Internet access, DXAdvanced can send messages anywhere in the world. An -capable cellular phone can be used to receive instantaneous remote notification of alarms. Also, a POP before SMTP function is included for user authentication when sending . Sending using an existing mail system In this type of setup, messages are sent through an existing mail server (SMTP server). Internet LAN Internet -capable cellular phone Mail reception DXAdvanced Mail server (SMTP server) Mail reception LAN Mail reception 10

11 PROFIBUS-DP and EtherNet/IP Functions DXAdvanced supports the PROFIBUS-DP slave and EtherNet/IP server functions. You can load or write measured data from DXAdvanced using a PLC or other master (client) device. * The PROFIBUS-DP function is optional PROFIBUS-DP EtherNet/IP Sequencer FTP File management and monitoring on an upstream host computer. Ethernet PLC or other PROFIBUS-DP master devices can access DXAdvanced s internal data and load measurement/math channels or write to communication input channels (max 32 ch). Sequencer DXAdvanced supports EtherNet/IP server functions. You can access DXAdvanced from PLCs or other devices and load measurement/math channels or write to communication input channels (max 60 CH). FTP Ethernet Device MW100 [Modbus TCP] and [Modbus RTU] Communications DXAdvanced supports MODBUS TCP/IP client and server modes for Ethernet communications and MODBUS RTU master and slave modes for optional serial communications. Both allow large amounts of external data points to be input to and processed by the DXAdvanced from external hardware such as Yokogawa s MW100. With this capability, a multi-point data acquisition system of up to 348 channels can be configured*. This bi-directional communication also allows the DXAdvanced to provide data to other devices such as a PLC. * External input option and mathematical functions option are required. Modbus TCP (Ethernet connection) Modbus client Up to 240 channels can be input from external I/O such as MW100*. The input data can be displayed and saved on the DXAdvanced. * DX2000 only. External input option is required. Ethernet Modbus RTU (RS-422A/485 connection) Modbus master The data of slave units can be displayed and saved on the DXAdvanced using the Modbus RTU function*. * Mathematical function option is required. RS-422A/485 MW100 Modbus server UT/UP series controller Power monitor etc. 11

12 Reliability and Security Proven Yokogawa measurement and recording technology Designed for continuous operation where failure is not an option, the nocompromise reliability of DXAdvanced protects vital plant data. High Level Security Functions [Secure, binary data file format] Measured data is saved in a proprietary, binary file format that is resistant to tampering with common software applications. The viewer software generates a message to warn the user if the data file is damaged or modified in any way. [Login function] This function enables only registered users to access the DXAdvanced. Five administrators and 30 common users can be registered in advance. A user can login by entering their user name, user ID, and password. ASCII data display [Front door lock] A mechanical lock with removable key is provided to securely latch the front panel door. This forbids access to the power switch and removable media. Binary data display [Key lock function] A password-protected key lock can be applied to each operation key or for access to the external storage media. [Highly reliable internal flash memory] Reliable, non-volatile flash memory is used for internal data storage operations with ECC* function. DXAdvanced retains important data during power failures of any duration with no battery protection circuit needed. * ECC: Error Check and Correct [Data redundancy] Measured and calculated data is continuously saved to secure, internal non-volatile flash memory. At manual or scheduled intervals, the files in memory are copied to the removable media, which is also secure flash memory. In addition, the files can be copied and archived to an FTP server. Because of the inherent reliability and security of flash memory and the storage methods used, the possibility of Measured data Internal memory External memory (CF card) losing data under any operating condition or power failure event is extremely small. When FTP transfer functions are used, three copies of the same data file can exist at the same time in three locations, thus providing a high level of redundancy. Data file A Data file B Data file C Data redundancy through the internal memory and external storage media. Auto save Copy Data file A Data file B Data file C 12

13 Robust Hardware [Dust-proof and water-proof front panel (IEC529-IP65, NEMA No.250 TYPE4* compliant)] Yokogawa designed the DXAdvanced to be used under harsh environmental conditions. The front panel has a dust-proof, water-proof design which is compliant with the IEC529-IP65 and NEMA No.250 TYPE4* standard. This structure provides good protection for the recorder's internal components as well as the removable storage media drive mechanism. *Except external icing test. [4 mm removable screw input terminals] Input terminals are the entryways through which all measurements enter a recorder. A reliable mechanical connection to the field wiring is critical for stable data collection. Rugged 4 mm screw input terminals are used on all DXAdvanced models. Input terminals can also be removed with the wiring attached to facilitate installation and maintenance. DX1000 [High-breakdown-voltage solid-state relays] DXAdvanced uses high-breakdown-voltage solid-state relays developed by Yokogawa as scanners for switching input signals. These relays consist of MOSFETs capable of withstanding high voltage (1500 V DC) with low leakage current (3 na), and poweroutput photocouplers. They provide highspeed scanning (125 ms/48 channels in the DX2048) while increasing scanner life and eliminating noise. DX2000 [Removable clamp input terminal] The removable clamp input terminal is available with the option (/H2). As this terminal is removable, it makes it very easy to change sensors such as thermocouples frequently. [Isolated channel inputs] DC voltage and thermocouple inputs in all DXAdvanced models are channel-isolated. (Channel isolation for RTD inputs is optional on some models.) The high common mode noise characteristic enabled by isolated channel inputs ensures stable measurements in a wide range of applications. Signal Input Circuit Diagram (The dotted section is isolated.*) * If the three-wire isolated RTD option is specified, the b terminal is also isolated between channels. +/A /B /b +/A /B /b +/A /B /b A/D Converter [Compliance with safety standards and EMC standards] Another indication of the reliability of DXAdvanced is their compliance with the stringent specifications for international safety and electromagnetic compatibility (EMC) standards. Of course, DXAdvanced have also been approved for the CE standards. Yokogawa EMC laboratory CSA: CSA22.2 No , installation category II, pollution degree 2 UL: UL (CSA NRTL/C) CE: EMC directive: EN61326 compliance (Emission: Class A, Immunity: Annex A) EN compliant EN compliant EN55011 compliant, Class A Group 1 Low voltage directive: EN compliant, measurement category II, pollution degree 2 C-Tick: AS/NZS CISPR11 compliant, Class A Group 1 13

14 Application Software For data management Configure settings and review historical data with a PC. Choose optional software for data acquisition, reporting, and other applications. DAQSTANDARD (Compatible with Windows 2000/XP/Vista) DAQSTANDARD is a standard software package included with the DXAdvanced. It can be used to print or redisplay historical data files saved by the DXAdvanced unit or transferred through FTP. [Data viewer] The Data Viewer module can be used to display and print data in files generated by the DXAdvanced unit. Data can be viewed in trend displays, digital displays, circular displays, and lists. In addition, the cursor can be used to read numerical values in displayed data, or to make interval calculations. Data can be converted to ASCII, or to file formats that can be opened in Excel or Lotus Data Viewer Data conversion window [Hardware configurator] All DXAdvanced configuration settings can be modified on-line via the network connection using the hardware configurator tool. This allows the user to configure the unit quickly and easily from a PC. In addition, an off-line configuration can be performed where the settings are saved to a file on the removable media, and then taken to the unit and loaded via the media drive. A catalog of setting files can be archived on both the PC and the unit for future use or modification. Measurement channel setting Environment setting 14

15 DAQWORX DAQWORX is a data acquisition software suite that integrates Yokogawa recorders, data acquisition instruments, and measurement instruments. [DAQLOGGER] (Compatible with Windows 2000/XP/Vista) [DAQEXPLORER] (Compatible with Windows 2000/XP/Vista) A data logging software application that enables Ethernet and serial communication to be used simultaneously. A mixture of DXAdvanceds, DARWIN data acquisition units, and ur recorders can be combined (32 units total) to achieve data acquisition of 1600 channels. DAQEXPLORER is a dedicated software program for the DX, CX, and MV that offers a combination of file transmission, PC-based monitoring, and other functions in addition to the DAQSTANDARD functions. It provides easy access to the wide array of DXAdvanced networking functions. Ethernet Ethernet DX1000 DX1000 DX2000 R10000 UT351 PR300 DX1000 DX1000 DX2000 DX2000 DX2000 Certain models require Gate software programs (drivers) separately, and connect only up to 16 units with Gate software connection. 15

16 SPECIFICATIONS See the general specifications (GS 04L41B01-01E, 04L42B01-01E) for the detailed specification STANDARD SPECIFICATIONS General Specifications Construction Mounting: Flush panel mounting (on a vertical plane) Mounting may be inclined downward up to 30 degrees from a horizontal plane. Allowable Panel Thickness: 2 to 26 mm Front Panel: Water and dust-proof (based on IEC529-IP65 and NEMA No.250 TYPE4*) Input Number of Inputs: DX1000: 2, 4, 6, 12 channels DX2000: 4, 8, 10, 20, 30, 40, 48 channels Measurement Interval: DX1002, DX1004, DX2004, DX2008: 125 ms, 250 ms, 25 ms (fast sampling mode*) DX1006, DX1012, DX2010, DX2020, DX2030, DX2040, DX2048: 1 s (Not available when A/D integration time is set to 100 ms), 2 s, 5 s, 125 ms (fast sampling mode*) * A/D integration time is fixed to 1.67 ms in case of fast sampling mode. Inputs: DCV (20, 60, 200 mv, 2, 6, 20, 50 V, 1-5 V) TC (R, S, B, K, E, J, T, N, W, L, U, WRe) RTD (Pt100, JPt100) DI (Contact input, TTL level) DCA (With external shunt resistor attached) Input Range Measurement accuracy Display (when the integration time is 16.7 ms or more) resolution DCV 1-5 V ±(0.05% of rdg+3 digits) 1 mv Thermocouple* K ±(0.15% of rdg+0.7 C) 0.1 C Resistance thermometer detector Pt100 ±(0.15% of rdg+0.3 C) 0.1 C * Does not include the accuracy of reference junction compensation Display Display unit: DX1000: 5.5-inch TFT color LCD (320 x 240 pixels) DX2000: 10.4-inch TFT color LCD (640 x 480 pixels) Display group: Number of display: DX1000: 10 groups, DX2000: 36 groups Number of assignable channels for one group: DX1000: 6 channels, DX2000: 10 channels Display color: Trend/Bargraph: Selectable from 24 colors Background: White or black selectable Trend display: Trend display type: Vertical, horizontal, landscape, horizontal split or circular* selectable * Circular display is only for DX2000. Bargraph display: Direction: Vertical or horizontal selectable Digital indication: Display renewal rate: 1 s Overview display: Number of indication channels: Measuring values and alarm status of all channels Information display: Alarm summary, message summary, memory information, report information, relay status, Modbus status Tag display: Tag number and comment display No. of displayable characters Tag no :16 max Tag comment :32max Displayable characters: Tag no.: Alphanumerics Tag comments: Alphanumerics, Japanese, and Chinese Messages: Number of characters: 32 characters maximum Number of messaged: 100 messages (including 10 free messages) Data referencing function: Display the retrieved data (display data or event data) from internal or external memory. Custom display function: User can change display object (trend, numeric, and bar graphs, etc.) sizes and attributes, and add objects freely to create screens. No. of screens: 28 (3 from internal memory, 25 from external media (CF)) Max no. of placeable display objects: 132 (normal: 80, scale: 4, trend: 4, list: 4, graphic: 40) Data Saving Function External storage medium: Medium: CompactFlash memory card (CF card) Internal memory: Medium: Flash memory Capacity: Selectable from 80MB or 200MB Maximum number of files can be saved: 400 files (total number of display data file and event data file) Alarm Function Number of alarm levels: Up to four levels for each channel Alarm types: High and low limits, differential high and low limits, high and low rate-of-change limits and delay high and low Alarm annunciator function: Alarm display based on alarm sequence, and relay output operation. Supported alarm sequences: 3 (ISA-A-4, ISA-A, ISA-M) Event action function General: Particular action can be executed by particular event. Number of event action: 40 actions can be set Security functions General: Login function or key lock function can be set for each key operation or communication operation. Key lock function: On/off and password can be set for each operation key and FUNC operation. Login function: User name and password to login can be set. Clock Clock: With calendar function (year of grace) Clock accuracy: ±10 ppm, excluding a delay (of 1 second, maximum) caused each time the power is turned on. DST function (summer/winter time): The time at which the daylight savings time adjustment is automatically calculated and configured. Communication Functions Connection: Ethernet (10BASE-T) Protocols: TCP, UDP, IP, ICMP, ARP, DHCP, HTTP, FTP, SMTP, SNTP, Modbus, DX private inform function: FTP client function: Transferred data file, FTP server function, Web server function, SNTP client function, SNTP server function, DHCP client function, Modbus client function, Modbus server function EtherNet/IP server Connects to EtherNet/IP networks as an Adapter (Server). Batch function General: Data display and data management with batch name, text field function and batch comment function are available. Power Supply Rated power supply: 100 to 240 VAC (automatic switching) Allowable power supply voltage range: 90 to 132 or 180 to 264 VAC Rated power supply frequency: 50/60 Hz (automatic switching) Power consumption: DX1000: 60 VA (max., for 240 VAC power supply) DX2000: 100 VA (max., for 240 VAC power supply) Normal Operating Conditions Power voltage: 90 to 132 or 180 to 250 VAC Power supply frequency: 50 Hz ±2%, 60 Hz ±2% Ambient temperature: 0 to 50 C Ambient humidity: 20% to 80% RH (at 5 to 40 C) SPECIFICATIONS OF OPTIONAL FUNCTIONS Alarm Output Relays (/A1, /A2, /A3, /A4*, /A5*) An alarm signal is output from the rear panel as a relay contact signal. Number or output: Select from 2, 4, 6, 12* and 24* points * Only for DX2000. Serial Communication Interface (/C2, /C3) Connection: EIA RS-232 (/C2) or RS-422A/485 (/C3) Protocols: DX private protocol, Modbus(master/slave) protocol Setting/measurement server function: Operation, setting or output of measurement data are available by DX private protocol. 16

17 Modbus communication: Reading or writing of measurement data on other instruments are available by Modbus protocol.* * /M1 option or /MC1 option is required to read data from other instrument. VGA Video Output (/D5) Resolution: 640 x 480 pixels (VGA) Fail/Status Output (/F1) The relay contact output on the rear panel indicates the occurrence of CPU failure or selected status. Fail & Alarm Output Relays 22 points (/F2, only for DX2000) Combination of "Fail/Status output function" and "Alarm output relays 22 points". Clamped Input Terminal (/H2) Clamped input terminal (detachable type) is used for input terminal. Desk Top Type (/H5[ ], /H5*) Provides carrying handle and power cord. * /H5 is only for 24 VDC/AC power supply model (/P1), and does not include power code. Mathematical Functions (/M1) Used for calculating data, displaying trends and digital values, and recording calculated data assigned to channels. Channel assignable to calculated data: DX1002, DX1004: 12 channels, DX1006, DX1012: 24 channels DX2004, DX2008: Up to 12 channels DX2010, DX2020, DX2030, DX2040, DX2048: 60 channels Operation: General arithmetic operations, Statistical operations, Special operations, Conditional operation Constant: Up to 60 constants (K01 to K60) Report functions: Report type: Hourly, daily, hourly + daily, daily +weekly and daily + monthly Operation: Max. 4 types are selectable from average, maximum, minimum, instantaneous and summation Cu10, Cu25 RTD Input /3 leg isolated RTD Input (/N1) This option allows Cu10 and Cu25 inputs to be added to the standard input types. 3 legs Isolated RTD Input (/N2*) A, B, b legs are of isolated input type. * Only fordx1006, DX1012, DX2010, DX2020, DX2030, DX2040 and DX2048. Extended Input Types (/N3) This option allows extra inputs types as below to be added to the standard input types. TC: Kp vs Au7Fe, PLATINEL, PR40-20, NiNiMo, W/Wre26, TypeN (AWG14) RTD: Pt25, Pt50, Ni100 (SAMA), Ni100 (DIN), Ni120, J263*B, Cu53, Cu VDC/AC Power Supply (/P1) Rated power supply: 24 VDC or 24 VAC (50/60Hz) Allowable power supply voltage range: 21.6 to 26.4 VDC/AC Max. power consumption: DX1000: 28 VA (24 VDC), 45 VA (24 VAC (50/60 Hz)) DX2000: 45 VA (24 VDC), 70 VA (24 VAC (50/60 Hz)) Remote Control (/R1) This option allows eight functions to be controlled remotely by a contact input. 24 VDC transmitter power supply (/TPS2*, /TPS4, /TPS8*) Output voltage: 22.8 to 25.2 VDC (rated load current) Rated output current: 4 to 20 madc * /TPS2 is only for DX1000, /TPS8 is only for DX2000 Easy text entry (/KB1, /KB2) Remote control terminal is available to operate the DX. Number of units that can be controlled: Max. 32 units by ID setting USB interface (/USB1) USB interface specification: Based on Rev1.1, host function Number of ports: 2 ports (Front and rear panel) Available USB devices: Keyboard: 104/89 keyboard (US) based on USB HID Class Ver.1.1 External medium: USB flash drive (Some of the USB flash drive may not be supported by DXAdvanced.) Pulse input (/PM1) Pulse input option includes mathematical functions option (/M1) and remote control option (/R1). Number of inputs: 3 points (8 points are available in case of using remote inputs) Input format: Photocoupler isolation (shared common) Isolated power supply for input terminal (approx. 5 V) Calibration correction function (/CC1) Corrects the measurement value of each channel using segment linearizer approximation. Number of segment points: 2 to 16 External input function (/MC1, only for DX2000) Digital input channels via communication are extended to input data from other instruments. Number of external input channels: Up to 240 channels (channel number: 201 to 440) * Only for DX2010, DX2020, DX2030, DX2040 and DX2048 * Fast sampling mode is not available when external input option is equipped. Multibatch function (/BT2) User can start/stop recording independently by batch, and create data files. No. of multibatches: DX1000:2 to 6 (DX1006,DX1012 only) DX (Standard memory) :2 to 6 DX (Large memory) :2 to 12 (DX2010,DX2020,Dx2030,DX2040,DX2048 only) PROFIBUS-DP communication interface function (/CP1) PROFIBUS-DP master devices can access the following internal data. Load measurement channel data Load MATH channel data Write communication input channel data (32 CH max) Node address setting range: 0 to 125 Interface: PROFIBUS-DP-V0 Slave Transmission medium: 2 dedicated cables Transmission speed/distance: 9.6 kbps/1200 m to 12 Mbps/100 m Termination resistance: None (requires external termination resistance) Dimensions DX1000 DX2000 Unit : mm (approx : inch) Two panel brackets are used in panel-mounting the DX1000 and DX2000. They may be used either on the left and right or top and bottom. See Yokogawa s General Specification (GS 04L41B01-01E) for information on panel cutting dimensions for DX1000 vertical or horizontal attachments. Unless otherwise indicated, tolerance is ±3% (or ±0.3 mm for dimensions under 10 mm). Daqstation and DXAdvanced are registered trademark of Yokogawa Electric Corporation. Microsoft, MS, and Windows are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Pentium are registered trademarks of Intel Corporation. Ethernet is a registered trademark of Xerox Corporation. Modbus is a registered trademark of AEG Schneider Automation Inc. Other company names and product names appearing in this document are registered trademarks or trademarks of their respective holders. PROFIBUS-DP is a registered trademarks of PROFIBUS User Organization. EtherNet/IP is a registered trademarks of ODVA(Open DeviceNet Vendor Association). 17

18 MODEL AND SUFFIX CODES DX1000 Model code Suffix code Optional code Description DX1002 2ch, 125ms (Fast sampling mode: 25ms) DX1004 4ch, 125ms (Fast sampling mode: 25ms) DX1006 6ch, 1s (Fast sampling mode: 125ms) DX ch, 1s (Fast sampling mode: 125ms) Internal -1 Standard memory (80MB) memory -2 Large memory (200MB) External media -4 CF card (with media) Display language -2 English, degf, DST(summer/winter time) Options /A1 Alarm output 2 points *1 /A2 Alarm output 4 points *1 /A3 Alarm output 6 points *1 *2 /C2 RS-232 interface *3 /C3 RS-422-A/485 interface *3 /F1 FAIL/Status output *2 /H2 Clamped input terminal (detachable) /H5 Desktop type (for /P1 model, without power code, screw type power terminal) *4 /H5[ ] Desktop type *5 /M1 Mathematical functions /N1 Cu10,Cu25 RTD input/3 leg isolated RTD /N2 3 leg isolated RTD *6 /N3 Extended input type (PR40-20, Pt50, etc.) /P1 24VDC/AC power supply /R1 Remote control /TPS2 24VDC transmitter power supply (2 loops) *7 /TPS4 24VDC transmitter power supply (4 loops) *8 /KB1 Easy text entry (with input terminal) *9 *10 /KB2 Easy text entry (without input terminal) *9 /USB1 USB interface /PM1 Pulse input (including remote control and mathematical functions) *11 /CC1 Calibration correction function /BT2 Multi-batch functions *12 /CP1 PROFIBUS-DP functions *3 *1 /A1, /A2 and /A3 cannot be specified together. *2 /A3 and /F1 cannot be specified together. *3 /C2, /C3 and /CP1 cannot be specified together. *4 In case that 24 VDC/AC power supply (/P1) and desktop type are specified together, /H5 must be specified. /P1 and /H5[] cannot be specified together. *5 /H5[ ] D: Power cord UL, CSA st'd F: Power cord VDE st'd R: Power cord SAA st'd J: Power cord BS st'd H: Power cord GB st'd APPLICATION SOFTWARE *6 /N2 can be specified for only DX1006 and DX1012. *7 In case that /TPS2 is specified, /TPS4, /A2, /A3 or /F1 cannot be specified together. *8 In case that /TPS4 is specified, /TPS2, /A1, /A2, /A3 or /F1 cannot be specified together. *9 /KB1 and /KB2 cannot be specified together. *10 In case that /KB1 is specified, remote input terminal (438227) is included. *11 In case that /PM1 is specified, /A3, /M1, /R1, /TPS2 or /TPS4 cannot be specified. And combination of /A2/F1 cannot be specified together. *12 /BT2 can be specified for only DX1006, DX1012. Model code Description OS DXA120 DAQSTANDARD Windows 2000/XP/Vista ACCESORIES Product Model code (part number) Specification Shunt resister W±0.1% (for screw input terminal) W±0.1% W±0.1% Shunt resister (for clamped input terminal) W±0.1% W±0.1% W±0.1% CF card adapter CF card MB MB MB GB Mounting bracket B9900BX - Door lock key B8706FX - Remote control terminal For /KB1, /KB2 option DX2000 Model code Suffix code Optional code Description DX2004 4ch, 125ms(Fast sampling mode: 25ms) DX2008 8ch, 125ms(Fast sampling mode: 25ms) DX ch, 1s(Fast sampling mode: 125ms) DX ch, 1s(Fast sampling mode: 125ms) DX ch, 1s(Fast sampling mode: 125ms) DX ch, 1s(Fast sampling mode: 125ms) DX ch, 1s(Fast sampling mode: 125ms) Internal -1 Standard memory (80MB) memory -2 Large memory (200MB) External media -4 CF card (with media) Display language -2 English, degf, DST(summer/winter time) Options /A1 Alarm output 2 points *1 /A2 Alarm output 4 points *1 /A3 Alarm output 6 points *1 /A4 Alarm output 12 points *1 /A5 Alarm output 24 points *1 *2 /C2 RS-232 interface *3 /C3 RS-422-A/485 interface *3 /D5 VGA output /F1 FAIL/Status output *2 *4 /F2 FAIL + Alarm output 22 points *1 *4 /H2 Clamped input terminal (detachable) /H5 Desktop type (for /P1 model, without power code, screw type power terminal) *5 /H5[ ] Desktop type *6 /M1 Mathematical functions /N1 Cu10,Cu25 RTD input/3 leg isolated RTD /N2 3 leg isolated RTD *7 /N3 Extended input type (PR40-20, Pt50, etc.) /P1 24VDC/AC power supply /R1 Remote control /TPS4 24VDC transmitter power supply (4 loops) *8 /TPS8 24VDC transmitter power supply (8 loops) *9 /KB1 Easy text entry (with input terminal) *10 *11 /KB2 Easy text entry (without input terminal) *10 /USB1 USB interface /PM1 Pulse input (including remote control and mathematical functions) *12 /CC1 Calibration correction function /MC1 External input function *13 /BT2 Multi-batch functions *14 /CP1 PROFIBUS-DP functions *3 *1 /A1, /A2, /A3, /A4, /A5, /F2 cannot be specified together. *2 /A5 and /F1 cannot be specified together. *3 /C2, /C3 and /CP1 cannot be specified together. *4 /F1 and /F2 cannot be specified together. *5 In case that 24 VDC/AC power supply (/P1) and desktop type are specified together, /H5 must be specified. /P1 and /H5[] cannot be specified together. *6 /H5[ ] D: Power cord UL, CSA st'd F: Power cord VDE st'd R: Power cord SAA st'd J: Power cord BS st'd H: Power cord GB st'd RELATED PRODUCT *7 /N2 can be specified for only DX2010, DX2020, DX2030, DX2040 and DX2048. *8 /TPS4, /TPS8, /A5 and /F2 cannot be specified together. *9 In case that /TPS8 is specified, combination of /A4/F1 cannot be specified together. *10 /KB1 and /KB2 cannot be specified together. *11 In case that /KB1 is specified, remote input terminal (438227) is included. *12 In case that /PM1 is specified, /A5, /F2, /M1 and /R1 cannot be specified. And combination of /A2/F1 and combination of /A4/TPS8 cannot be specified together. *13 /MC1 can be specified for only DX2010, DX2020, DX2030, DX2040 and DX2048. *14 /BT2 can be specified for only DX2010, DX2020, DX2030, DX2040, DX2048. DXAdvanced Removable Chassis Model DX1000N Removable Chassis Model featuring easy maintenance. This model enebles you to pull the inner chassis out from the case without having to remove the power supply, communication, and input wiring on the rear panel NOTICE Before operating the product, read the instruction manual thoroughly for proper and safe operation. If this product is for use with a system requiring safeguards that directly involve personnel safety, please contact the Yokogawa sales offices. YOKOGAWA ELECTRIC CORPORATION Network Solutions Business Div./Phone: (81) , Fax: (81) ns@cs.jp.yokogawa.com YOKOGAWA CORPORATION OF AMERICA Phone: , Fax: (1) YOKOGAWA EUROPE B.V. Phone: (31) , Fax: (31) YOKOGAWA ENGINEERING ASIA PTE. LTD. Phone: (65) , Fax: (65) Sign up for our free newsletter Printed in Japan, 809(KP) Vig-RS-2E [Ed :04/b] Subject to change without notice. All Rights Reserved, Copyright 2005, Yokogawa Electric Corporation.

DX1000/DX2000. Bulletin 04L41B01-01E.

DX1000/DX2000. Bulletin 04L41B01-01E. DX1000/ Bulletin 04L41B01-01E www.daqstation.com The debut of DXAdvanced R4 is here! Evolved features for greater utility The evolution of the global standard in paperless recorders has reached the next

More information

Daqstation DXAdvanced DX1000/DX2000. Bulletin 04L41B01-01E.

Daqstation DXAdvanced DX1000/DX2000. Bulletin 04L41B01-01E. Daqstation DXAdvanced / / Bulletin 04L41B01-01E www.daqstation.com Envision a plant... VigilantPlant excels at bringing out the best in your plant and your people - keeping them fully aware, well informed,

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Portable Paperless Recorder MV1000/MV2000 www.mv1000.com Bulletin 04Q01A01-01E Measurement scenarios that call for speed

More information

Portable Paperless Recorder MV1000/MV2000

Portable Paperless Recorder MV1000/MV2000 Portable Paperless Recorder MV1000/MV2000 www.mv1000.com Bulletin 04Q01A01-01E Measurement scenarios that call for speed and accuracy: MVAdvanced accurately captures precious evaluation data on the test

More information

General Specifications

General Specifications General Specifications MVAdvanced MV1000/MV2000 GS 04Q01A01-01E OVERVIEW The MVAdvanced MV1000/MV2000 is a portable recorder that displays real-time measured data on a color LCD and saves data on a CompactFlash

More information

Technical Information

Technical Information Technical Information TI 04L41B01-02E DAQSTATION DXAdvanced (DX1000/DX2000) Functions Overview TI 04L41B01-02E Copyright Oct. 2005 1st Edition Nov. 2005 Contents Contents... 2 Foreword... 6 1 Overview

More information

General Specifications

General Specifications General Specifications DAQSTATION DX2000 GS 04L42B01-01E OVERVIEW The DX2000 is a DAQSTATION that displays real-time measured data on a color LCD and saves data on a CompactFlash memory card (CF card).

More information

General Specifications

General Specifications General Specifications Daqstation DX1000 GS 04L41B01-01E OVERVIEW The DX1000 is a DAQSTATION that displays real-time measured data on a color LCD and saves data on a CompactFlash memory card (CF card).

More information

General Specifications

General Specifications General Specifications DAQSTATION DX1000 GS 04L41B01-01E OVERVIEW The DX1000 is a DAQSTATION that displays real-time measured data on a color LCD and saves data on a CompactFlash memory card (CF card).

More information

User s Manual RD-MV1000/RD-MV2000 M st Edition

User s Manual RD-MV1000/RD-MV2000 M st Edition User s Manual RD-MV1000/RD-MV2000 1st Edition How to Use This Manual Content Summary This user s manual consists of the chapters listed below. For information about the communication features and the accompanying

More information

Saved Data playback Saved data in Memory card can be easily called out and played back on display

Saved Data playback Saved data in Memory card can be easily called out and played back on display Paperless Recorder Type:PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played

More information

General Specifications

General Specifications General Specifications DAQSTATION DX364 GS 04L70B01-01E OVERVIEW The DX364 is a paperless recorder corresponding 1/2 DIN or 3 x 6 (inch) recorders. It can be hooked up to network via Ethernet, which enables

More information

PAPERLESS RECORDER FX1000

PAPERLESS RECORDER FX1000 PAPERESS RECORDER FX1000 Paperless Recorder Bulletin 0421B01-01EN www.fxrecorder.com At YOKOGAWA, we are committed to the quality first, customer first principle in all areas of our business, including

More information

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology! Now with Touch Screen Technology! PPS-1000 PPS-2000 PPS-3000 Product Overview The PPS Series is a major advance in the market for Paperless Videographic Data Recorders incorporating Touch Screen Technology

More information

User s Manual Model DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N

User s Manual Model DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N User s Manual Model DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N IM 04L41B01-01E 7th Edition Thank you for purchasing the Daqstation DX1000 (hereafter referred

More information

User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000

User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000 User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000 Yokogawa Electric Corporation IM 04L42B01-01E 8th Edition Introduction Thank you for purchasing the Daqstation DX2000

More information

Compact data logger offering best-in-class noise resistance and communication function

Compact data logger offering best-in-class noise resistance and communication function T M Portable Data Station XL100 Series Compact data logger offering best-in-class noise resistance and communication function A world s first in measuring instruments! To obtain IPv6 Ready Logo Phase-1

More information

General Specifications

General Specifications General Specifications Daqstation DX2000T GS 04L45B02-01EN OVERVIEW The DX2000T is a Daqstation that displays real-time measured data on a color LCD and saves data on a CompactFlash memory card (CF card).

More information

DAQSTATION NETWORK ENHANCED MODEL

DAQSTATION NETWORK ENHANCED MODEL DAQSTATION Network Enhanced Model DX230 288 288 220 7.3 kg (11.34 11.34 9.72" 16.1 lbs) DX112 144 144 218 3.0 kg (5.67 5.67 9.50" 6.6 lbs) Safety Standards; CSA22.2 No.1010.1 (CSA NRTL/C) EN61010-1 EMC

More information

MW100. Data Acquisition Unit. Data Acquisition Unit MW100.

MW100. Data Acquisition Unit. Data Acquisition Unit MW100. Acquisition Unit MW0 MW0 Acquisition Unit The MW0 is a scalable, high performance data acquisition/data-logging platform designed for both PC-controlled and stand-alone operation under harsh operating

More information

DAQSTATION DX Circular Display Model DX200C

DAQSTATION DX Circular Display Model DX200C DAQSTATION DX Circular Display Model DX200C The DX Series of DAQSTATION display measurement data in real-time on a high resolution TFT color liquid crystal display. Data can be saved to 3.5- inch floppy

More information

General Specifications

General Specifications General Specifications Daqstation DX2000 OVERVIEW The DX2000 is a DAQSTATION that displays realtime measured data on a color LCD and saves data on a CompactFlash memory card (CF

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

User s Manual. Models /436102/436103/436104/ µr10000 Recorder Portable Type. IM 04P01B01-51E 1st Edition. Yokogawa Electric Corporation

User s Manual. Models /436102/436103/436104/ µr10000 Recorder Portable Type. IM 04P01B01-51E 1st Edition. Yokogawa Electric Corporation User s Manual Models 436101/436102/436103/436104/436106 µr10000 Recorder Portable Type * 4 P 1 B 1 5 1 E 0 1 * Yokogawa Electric Corporation 1st Edition Foreword Notes Trademarks Revisions Thank you for

More information

ARF100 Paperless Recorder

ARF100 Paperless Recorder No. CP-SS-1846E ARF100 Paperless Recorder The ARF100 Paperless Recorder features a highly visible 5.6-inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling

More information

DAQSTATION Network Enhanced Model

DAQSTATION Network Enhanced Model DAQSTATION Network Enhanced Model DX100/DX200 DAQSTATION DX Series Network Enhanced Models display measurement data in real-time on a high resolution TFT color liquid crystal display. Data can be saved

More information

PAPERLESS RECORDER OUTLINE FEATURES SPECIFICATIONS. Easy operation with touch panel providing an intuitive user interface

PAPERLESS RECORDER OUTLINE FEATURES SPECIFICATIONS. Easy operation with touch panel providing an intuitive user interface Specifications Sheet No.SPEC-42E (st Edition) M7000A PAPERLESS RECORDER OUTLINE The M7000A is a paperless recorder that displays measured data on the LCD in real time and stores data in the SD memory card.

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

User s Manual. Models /437102/437103/437104/ /437112/437118/437124/ µr20000 Recorder Portable Type. IM 04P02B01-51E 1st Edition

User s Manual. Models /437102/437103/437104/ /437112/437118/437124/ µr20000 Recorder Portable Type. IM 04P02B01-51E 1st Edition User s Manual Models 437101/437102/437103/437104/ 437106/437112/437118/437124/ µr20000 Recorder Portable Type * 4 P 2 B 1 5 1 E 0 1 * Yokogawa Electric Corporation 1st Edition Foreword Notes Trademarks

More information

PR Series Paperless Recorders

PR Series Paperless Recorders PR Series Paperless Recorders Head Office: Brainchild Electronic Co., Ltd. 209 Chongyang Road, Nangang Dist., Taipei 11573, Taiwan Tel: +886-2-2786-1299 Fax: +886-2-2786-1395 Website: www.brainchild.com.tw

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology! Now with Touch Screen Technology! PPS-1000 PPS-2000 PPS-3000 Product Overview The PPS Series is a major advance in the market for Paperless Videographic Data Recorders incorporating Touch Screen Technology

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

DX1000/DX1000N/ DX2000

DX1000/DX1000N/ DX2000 User s Manual Daqstation DX1000/DX1000N/ DX2000 and DAQSTANDARD Functional Changes Resulting from the Updating (Applies to DX1000/DX1000N/DX2000 with hardware style 2 or later and firmware release 2 or

More information

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal

More information

Web-enabled DAQ System

Web-enabled DAQ System 2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing

More information

User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder

User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder IM 04L21B01-01EN 4th Edition Introduction Thank you for purchasing the FX1002, FX1004, FX1006, FX1008, FX1010, or

More information

ARF200. Paperless Recorder Advanced Recorder

ARF200. Paperless Recorder Advanced Recorder No. CP-SS-1871E ARF200 Paperless Recorder Advanced Recorder Overview The ARF200 Paperless Recorder adopts a highly visible 12.1-inch TFT color LCD, incorporates advanced functions, is easy to use, and

More information

User s Manual. FX100(Desktop Type) IM 04L20A01-51E 1st Edition. Yokogawa Electric Corporation. Model FX103/FX106/FX112

User s Manual. FX100(Desktop Type) IM 04L20A01-51E 1st Edition. Yokogawa Electric Corporation. Model FX103/FX106/FX112 User s Manual Model FX103/FX106/FX112 FX100(Desktop Type) * 4 L 2 0 A 1 5 1 E 0 1 * Yokogawa Electric Corporation 1st Edition Forword Notes Trademarks Revisions Thank you for purchasing the FX100. This

More information

User s Manual. Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide

User s Manual. Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide User s Manual Models DX1002/DX1004/DX1006/DX1012/ DX1002N/DX1004N/DX1006N/DX1012N Daqstation DX1000/DX1000N Operation Guide * 4 L 4 1 B 1 0 2 E 0 1 * Yokogawa Electric Corporation 1st Edition Contents

More information

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety

iologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety iologik 4000 Series Modular remote I/O I/O expansion without a backplane Supports SNMPv1/v2c Active communications with MX-AOPC UA Server Easy configuration with Modular ioadmin utility Friendly configuration

More information

XL112, XL114 ポータブルデータロガ

XL112, XL114 ポータブルデータロガ User's Manual Introduction Thank you for purchasing our XL100 Portable Data Station/Portable Data Logger. This Quick Setup Manual briefly describes the key operations as well as setting examples of the

More information

SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System

SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System The SmartView 280 Paperless Data Acquisition System (SV280) provides a cost-effective upgrade from existing

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning

More information

Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver

Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver Type: PHU Long Term Record Data Saving years in Compact Flash (In case of using 5MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display Math

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Industrial Control SE-607

Industrial Control SE-607 Industrial Control SE-607 Controller and visualization combined as an automation solution with infrared touch operation Trend-setting industrial controls for heat treatment plants The controller is equipped

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020 USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com

More information

RD2000, 5.6" display. All models shown smaller than actual size.

RD2000, 5.6 display. All models shown smaller than actual size. Paperless Recorders RD1000/RD2000/RD3000 Series RD1000, 4.3" display RD2000, 5.6" display RD3000, 12.1" display All models shown smaller than actual size. Color TFT Touch Screen Display: 4.3", 5.6" and

More information

General Specifications

General Specifications General Specifications GS 04L65B01-01EN GA10 Data Logging Software Overview Data Logging Software GA10 (hereafter referred to as GA10) is used to collect data from measuring instruments and controllers

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

GX/GP. Data Acquisition & Control. Paperless recorder. Bulletin 04L51B01-01EN

GX/GP. Data Acquisition & Control. Paperless recorder.  Bulletin 04L51B01-01EN Paperless recorder GX/GP Data Acquisition & Control Bulletin 04L51B01-01EN www.smartdacplus.com Your business environment is complex and fast changing. You need smart and powerful systems that can adapt

More information

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing Supports EtherNet/IP* adapter mode Supports RESTful API for IIoT applications 2-port Ethernet

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information

Industrial Recorders. Bulletin 04P01B01-01E

Industrial Recorders.  Bulletin 04P01B01-01E Industrial Recorders µr Intelligent Industrial Recorders The µr is a small compact industrial recorder with a recording width of mm. The model family consists of,,3, pen and a 6 dot model. Bulletin PB-E

More information

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus

More information

100mm Process Indicator Recorder

100mm Process Indicator Recorder Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing

More information

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL820 midi Logger Built-in 5.7" TFT LCD Color Display Stand-alone or PCconnected operation 20 Analog Channels Standard, Expandable to 200 Input-to-output and channel-to-channel Isolation USB and Ethernet

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Active communication with patented MX-AOPC UA Server and Active OPC server Smart alarm management with email, SNMP traps, TCP, UDP Save

More information

PAPERLESS RECORDER SPECIFICATIONS PHF DATA SHEET. Input system. EDS10-77d

PAPERLESS RECORDER SPECIFICATIONS PHF DATA SHEET. Input system. EDS10-77d PAPERLESS RECORDER DATA SHEET PHF This is a paperless recorder that displays measured data on the LCD in real time and stores data in CompactFlash. The type of input such as thermocouple, resistance bulb,

More information

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications

I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications RTU 20 OVERVIEW The I/A Series RTU 20 is an Intelligent Remote Device capable of performing a full range of control

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

Data Acquisition & Control. Bulletin 04L52B01-01EN.

Data Acquisition & Control. Bulletin 04L52B01-01EN. Data Acquisition & Control Bulletin 04L52B01-01EN www.smartdacplus.com Your business environment is complex and fast changing. You need smart and powerful systems that can adapt to your process. is a fresh

More information

/8 DIN Motorized Valve Controller

/8 DIN Motorized Valve Controller Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation

More information

DX1000/DX1000N/DX2000 Communication Interface

DX1000/DX1000N/DX2000 Communication Interface User s Manual DX1000/DX1000N/DX2000 Communication Interface 7th Edition Thank you for purchasing the DX1000/DX2000. This Communication Interface User s Manual contains information about the Ethernet/ serial

More information

Multi Channel Data Logger

Multi Channel Data Logger Multi Channel Data Logger :: User Friendly Touchscreen Interface :: Available in Panel Mount or Portable :: State of the art secure Data Logging :: 5.7-inch or 8.4-inch 64K color QVGA/SVGA Touchscreen

More information

Industrial Recorders

Industrial Recorders Industrial Recorders µr0000/µr0000 Intelligent Industrial Recorders The µ R series are the compact industrial recorders with the recording widths of 00 mm and 80 mm. The 00 mm family consists of,,3,4-pen

More information

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty

iologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty ioogik E4200 Modular Active Ethernet I/O adaptor Supports up to 16 I/O modules Dual Ethernet ANs and one RS-232 port Front-end intelligence that supports 80 Click&Go rules Unicode Active Messaging with

More information

Optional Code. Paperless recorder, small display (recommended) GP20 1. Paperless recorder, large display Type -1 Standard Display Language

Optional Code. Paperless recorder, small display (recommended) GP20 1. Paperless recorder, large display Type -1 Standard Display Language PendoTECH PressureMAT : Yokogawa Integration 1. Introduction The PendoTECH PressureMAT pressure monitor and transmitter (PMAT) and PMAT plus are used to read inputs from an assortment of PendoTECH Sensors.

More information

AC 800M for Compact Product Suite Outline of all modules

AC 800M for Compact Product Suite Outline of all modules DATA SHEET AC 800M for Compact Product Suite Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

General Specifications

General Specifications General Specifications GS 04L65B01-01EN GA10 Data Logging Software Overview Data Logging Software GA10 (hereafter referred to as GA10) is used to collect data from measuring instruments and controllers

More information

SCADAPack Smart RTU

SCADAPack Smart RTU SCADAPack 330 334 Smart RTU 1 Built on the proven SCADAPack 300 platform, the SCADAPack 330 and 334 feature high-performance 32-bit processing, highspeed LAN, serial and USB communications, integrated

More information

BACnet Controller for General-purpose Building Applications

BACnet Controller for General-purpose Building Applications Specifications BACnet Controller for General-purpose Building Applications General Model WJ-1101 is the BACnet controller to be used for a wide range of building applications such as air-conditioning and

More information

General Specifications

General Specifications General Specifications DAQManager Data Management Software for Paperless Recorders [Release: R2] Overview DAQManager is a software program that enables you to manage measured data from Daqstation and MVAdvanced

More information

PXR Series Advanced Self-Tuning Temperature and Process Controllers

PXR Series Advanced Self-Tuning Temperature and Process Controllers PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater

More information

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway Smart Energy & Power Quality Solutions ProData datalogger Datalogger and Gateway Smart and compact: Our most universal datalogger ever saves power costs Ethernet connection Modbus-Ethernet-Gateway 32 MB

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

1/2 Description XV400 Flexible in Application

1/2 Description XV400 Flexible in Application 1/2 Description XV400 Flexible in Application HMI or combined HMI-PLC with the XV400 series, the customer decides on the device functions and the preferred project engineering tool. Devices in the XV400

More information

User friendly and easy to program

User friendly and easy to program New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric

More information

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour. GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and

More information

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES 11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Nuclear Solutions. Data Acquisition, Control, and Monitoring Solutions for Nuclear Power. Bulletin 04L70B01-02E-A

Nuclear Solutions. Data Acquisition, Control, and Monitoring Solutions for Nuclear Power. Bulletin 04L70B01-02E-A Nuclear Solutions Data Acquisition, Control, and Monitoring Solutions for Nuclear Power Bulletin 4L7B1-2E-A Newnan, GA Calgary, Canada Houston, TX Mexico City Yokogawa provides proven and highly reliable

More information

Ideal for temperature measurement, monitoring and management of temperature data records. Thermometers

Ideal for temperature measurement, monitoring and management of temperature data records. Thermometers Ideal for temperature measurement, monitoring and management of temperature data records Thermometers The TM Series offers excellent data management functions Collect up to 5000 data items with time-stamp,

More information

Features and Benefits. Certifications

Features and Benefits. Certifications iologik E2200 Series Smart Ethernet remote I/O with Click&Go Logic Features and Benefits Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA

More information

INSTRUCTION MANUAL V1. 2x A

INSTRUCTION MANUAL V1. 2x A INSTRUCTION MANUAL V1. 2x A INTRODUCTION... 3 CONNECTIONS AND INSTALLATION... 4 MECHANICAL INSTALLATION... 4 ATTACHING AND DETACHING THE FRONT COVER... 8 ATTACHING AND DETACHING THE HMI... 9 ELECTRICAL

More information

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet OVERVIEW The DATAWATCH IX monitor offers an excellent graphical display and recording device for a box of its size. The compact panel mount unit offers four isolated or eight non-isolated high accuracy

More information

Micro-Modular Programmable Controller

Micro-Modular Programmable Controller Micro-Modular Programmable Controller Productivity2000 Features CPU with 5 communication ports OLED message display on CPU module Plenty of discrete and analog I/O modules Status displays on all discrete

More information

WIDE CASE EXPANDABLE MODEL

WIDE CASE EXPANDABLE MODEL WIDE CASE EXPANDABLE MODEL Designed to replace obsolete Westronics D11E, M11E, and 3200 series paper recorders, the DX200 wide case models can now handle applications that require up to 230 inputs. Bulletin

More information

Technical Information

Technical Information Technical Information DAQMASTER Replacement Guide MX100 GM MW100 The contents of this Technical Information are subject to change without notice. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi,

More information

iologik E1200H Series

iologik E1200H Series iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information