Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver

Size: px
Start display at page:

Download "Long Term Record Data Saving. Saved Data playback. Math and totalization. Communication Ethernet (10Base-T) is available. (option) Screen saver"

Transcription

1 Type: PHU Long Term Record Data Saving years in Compact Flash (In case of using 5MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played back on display Math and totalization These functions are available as standard. Communication Ethernet (0BaseT) is available. (option) Screen saver Period of nonoperation exceeds the setting value of parameter, recorder turns off the backlight of LCD. PC support softwares (Data Viewer/Parameter Loader) Supplied in a CDROM as a part of standard accessory 6point max. recording types of thermocouples, 5 types of resistance s and voltage/ current input are available ECNO:06b

2 Provides flexibility and variety in the handling of record data. Status Display Allows you to display screen name, calendar, alarm information, recording status, writing status of measured data in Compact Flash, and fitting status of the card into the recorder slot. Time display Indicates the time and time scale of recorded data. Trend Display Allows you to view measured result in waveforms. Digital Display Allows you to view measured values in a digital form. Key panel Allows you to perform the recording start/stop, selection of display, setting, data display/change. Power indicator During power on, LED turns on. While screen saver is working, it flickers. About years' worth of data can be recorded in Compact Flash (5 MB). When recorded in ASCII mode, for channels, and with a recording cycle of 0 seconds. Mathematics function (programming formula) as standard You can program formula using below operand. Addition, Subtraction, Multiplication, Division Absolute value, X to the power of Y, Logarithm, Natural logarithm, Exponential function, Humidity, Average value, Maximum value, Minimum value. Communication Ethernet (0BaseT) is available. It has FTP, HTTP (Web server), SMTP and MODBUSTCP protocols. Calculation function offered as standard Subtraction Difference between the values of each channel can be calculated. F value calculation Extinction rate of bacteria by heat sterilization can be calculated per channel according to the measured temperature. Totalization Measured value of each channel can be totalized. Reference time can be selected from day, hour, minute and second. Square root extraction Square root extraction of the input value of each channel can be performed.

3 Wide variety of display mode Trend recording (horizontal) Measured result is horizontally displayed in real time. Trend recording (vertical) Measured result is vertically displayed in real time. Bar graph Measured values are displayed in bar graph. Analog meter Measured values are displayed in analog meters. Digital display Channel No., Tag No. engineering unit, and alarm information are displayed in digital form, in addition to measured values. Totalized data display Totalized data of each channel is digitally displayed. (If power failure occurs while in totalizing operation and the power is restored later, the data being totalized is cleared.) Historical trend display Past data saved to Compact Flash can be viewed. Scroll function is usable. Event summary display Alarm status and external control input status for each channel are displayed.

4 General specifications Mounting method Panel flush mounted Material steel sheet for case, PCABS for bezel External dimensions <Panel mount> and mass 00 x 00 x 0.5 mm, about. kg (point input) Power supply voltage 0 to AC, 50/60 Hz Power consumption About A (at AC) External terminals Screw terminals (M thread) Operate temperature 0 to 50 C (in case the th digits of code symbols is Y.) 0 to 0 C (in case the th digits of code symbol Input unit No. of inputs Measuring cycles Recording cycle Input signal Input types Burnout function Calculation function Mathematics function Formula Addition, Subtraction, Multiplication, Division Absolute value, X to the power of Y, Logarithm, Natural logarithm, Exponential function, Humidity, Average value, Maximum value, Minimum value. Input signal ( to 6), Totalize (ch to ch), Analog input (ch to ch), Constant (No. to No.60), Display unit Display Life of backlight Display contents Recording function Recording medium is E.) or or or 6 points 00ms/, points 00ms/, 6 points sec to hours Thermocouple: types (B, R, S, K, E, J, T, N, W, L, U, PN) : 5 types (Pt00, JPt00, Ni00, Pt50, Cu50) DC voltage: (0 to 50mV, 0 to 500mV, 0 to 5V or to 5V) DC current: (connecting optional shunt resistor to input terminal) Selected from the key panel (the same type should be set for every channels) Equipped with thermocouple and resistance inputs as standard. Primary delay filter, scaling, calculation of difference between channels, F value calculation, totalization, and square root extraction It can be set main formula and temporary one. Communication input (No. to No.6) " TFT color LCD (00 X 600 dots) (The LCD may have some pixels that do not stay on or off. Due to the characteristics of liquid crystal, the brightness may not be uniform, which is not a failure.) 50,000 hours Trend display (in vertical and horizontal direction) selected in the refreshment cycles of sec to hours. Scale display/nondisplay selectable Bar graph or analog meter display (refresh cycle: second) Digital display (in refreshment cycle of sec) Event summary display (alarm and message summary) Historical trend display (Compact Flash memory data.) Totalized data display Group setting ( groups at the maximum) Compact Flash card (Format as FAT6 or FAT, or recorder can t read and write.) Specifications Memory capacity GB, max. Recording method Writing starts in fixed cycles by turning ON the REC key on the front panel. Data is recorded in a new file every time the recording starts. Data save cycles Links to refreshment cycle of the trend display Data format ASCII About 66 bytes per sampling (at channel inputs) Binary (Data cannot be read directly into Excel, etc.) About 0 bytes per sampling (channel input) Trend data Maximum value and minimum value are saved from the data that are sampled in measuring cycles. Event data Alarm data and message data are saved. Totalized data Stores data totalized during specified period of time. Storage capacity About.5 years at display refresh cycle of 0 seconds (ASCII) About 6 years (Binary) (channel recording, 56MB compact flash used) Amount of memory The display unit displays how much the memory used card has been used via bar graphs. The recording will stop if the amount of recorded data exceeds the capacity. Alarm function No. of settings Type of alarm Indication Output Reference performance Others Optional specifications Alarm relay output Up to alarms are settable for each channel. High/Low limits Alarm status is displayed on digital display unit when an alarm occurs. Histories are displayed in the alarm summary. 0 points as relay output (option) 6 points as opencollector transister output (option) Indication accuracy ±(0.5% digit) of input range Accuracy of the next range is ±(0.% digit). Thermocouple B: 00 C to 600C, thermocouples R and S: 0 C to 00 C, thermocouples K, E, J, T, L, and U: 00 C to 00 C Indication resolution 0. C Reference junction ±0.5 C Compensation accuracy (Thermocouples R, S, B and W: ±.0 C) Input resistance About M Clock With calendar function Memory backup Parameter settings are saved to the internal nonvolatile memory. The clock is backed up by a builtin lithium battery. Trend data is back up 5 Mbyte. Memory full alarm When the amount of recorded data exceeds the capacity of memory card, recorder can energize the alarm output. Low battery alarm When the battery for backup of clock and SRAM becomes low, recorder can energize the alarm output. Up to pieces of card, having 0point relay output, can be mounted max.0points. : a contact Alarm setting: individual channel or common output is available.

5 Alarm opencollector output input Communication (Ethernet) A card, having 6point open collector output, can be mounted. : open collector output A card, having 6point input, can be mounted. input: novoltage contact input Contents of control: Recording start/stop, Message setting, F value caliculation resetting, Totalizing start/ stop, Totalizing reset, LCD turning. 0BaseT FTP server * (Internet Explorer 6. FFFTP or Comand Prompt are available) HTTP server * (Web server. Internet Explorer 6 is available) SMTP ( client) MODBUSTCP * Netscape and Mozilla Firefox are not available Specifications PC support software (standardsupplied CDROM) O/S Windows XP/000 PC/ATcompatible Operation on PCseries machines by NEC is machine not guaranteed. Operation on selfmade or shopbrand PCs is not guaranteed. Required memory 6 MB or more capacity Contents The following types are included as standard. ) Data viewer software It allows you to view the past trend recorded data from the data saved to the Compact Flash on PC. Historical trend and event display functions are provided. ) Parameter loader software It allows you to perform setting/change of various parameters on PC. A convenient PC support software package is included as standard Past data saved to Compact Flash can be viewed on personal computer. Parameters for the recorder can be easily set and changed from personal computer. Historical trend data screen Parameter setting screen Before use, install PC support software supplied as standard. O/S: Windows XP/000 Required storage capacity: 6 MB Provide PC card adapter separately. Recomended type: SDAD (SanDisk Co.) PC/ATcompatible machine Operation on PCseries machines by NEC is not guaranteed. Operation on selfmade or shopbrand PCs is not guaranteed. Before use, install PC support software supplied as standard. O/S: Windows XP/000 Required capacity of memory: 6 MB A communication cable between recorder and pc is optional. Type: PHZP0 PC/ATcompatible machine Operation on PCseries machines by NEC is not guaranteed. Operation on selfmade or shopbrand PCs is not guaranteed. 5

6 PUSH PUSH PUSH PUSH DO0 DO0?iTr?j DO6 DO0 DO0?iTr?j DO6 DO0 DO0?iTr?j DO6 DO0 CH CH6 6 CH CH CH º i 0 5 CH CH6 6 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 N DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CH DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 N DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CH CHCH CHCH CH CH CH º i 0 5 CH CH6 º i 6 DO0 º i?itr?j DO6 º i CH0 0 CH0 CH5 5 CH CH6 º i 6 6 CH CH 5 CH6 CH CH CH CH 0 CH CH DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 0 CH5 5 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CHCH CH5 CH5 5 ã i 5 ã i LAN Communicator LAN Communicator CH0CH 00AC?` 00AC?` 6 CH0 CH CH CH CH ã i CH5 CH6 CH CH º i DO DO DO DO DO5 DO6 DO DO DO DO0 N 6 RMODULE CHCH CH 5 CH6 CH 6 RMODULE CH 50 CH CH CH DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO6 DO DO DO DO0 5 DO DO DO DO DO5 DO6 DO DO DO DO0 DO DO DO DO DO5 DO DO DO PCD DO DO0 DO DO DO DO DO5 DO6 PCD CH CH 0 CHCH CH RMODULE CHCH CH 6 RMODULE CH 50 CH CH CH CH5 5 L L 6 Outline Diagrams (Unit: mm) input points 00 Panel relay terminal Ethernet terminal (option) input terminal transistor terminal input points 00 Panel relay terminal Ethernet terminal (option) input terminal transistor terminal RMODULE RMODULE RMODULE 5 5 ã i CH CH ã i CH 5 CH5 5 5 ã i CH CH ã i CH 5 LAN Communicator CH0CH 00AC?` 6 CH0 CH CH CH CH ã i CH5 CH6 CH CH º i CH0 CH CH CH CH ã i CH5 CH6 CH CH º i º i L t t Mounting bracket ( to points) t t Mounting bracket ( to points) (0 to points) input points 00 Panel relay terminal Ethernet terminal (option) input terminal transistor terminal 00 RMODULE CH LAN Communicator 5 6 CH CH CH 0 CH0CH RMODULE CHCH6 CH0 0 RMODULE 00AC?` DO DO DO DO DO5 DO6 DO DO DO DO0 N 0 0 L CH CH 5 6 ã i CH5 CH t t Mounting bracket ( to points) (0 to points) ( to points) 6 input points 00 Panel relay terminal Ethernet terminal (option) input terminal transistor terminal 00 t t Mounting bracket ( to points) (0 to points) ( to points) ( to 6 points) Panel cutout 0 60 MIN 0 MIN 0 6

7 External connection diagrams relay terminal M screw DO DO DO DO DO5 5 DO6 6 DO DO DO DO M screw relay terminal 00 to AC 50/60Hz M screw DO DO DO DO DO5 5 DO6 DO DO DO DO transistor terminal input terminal M screw M screw DO DO DO DO 5 DO5 6 DO DO DO PCD V DC DO DO0 DO DO DO DO DO5 DO Number of input points = to points M screw Number of input points = 0 to points CH CH CH CH CH5 CH0 CH CH CH CH Thermocouple Thermocouple Thermocouple Thermocouple CH6 CH CH CH CH5 CH6 CH CH Number of input points = to points Number of input points = to 6 points CH CH0 CH CH CH CH CH CH0 CH CH Thermocouple Thermocouple Thermocouple Thermocouple CH CH5 CH CH CH CH CH5 CH6 Note) For current input, connect an optional shunt resistance to a voltage input terminal.

8 Code Symbols PHU V Digit Specifications <Number of input points> points points points 6 points < input> Without With (6 points) <Modification No.(fixed)> <Display (instruction manual)> English <> Without 0 relay points 0 relay points Transistor (open collector) 6 points 0 relay points transistor (open collector) 6 points 0 relay points transistor (open collector) 6 points <Ethernet> Without With Note 0 E 0 5 Y E Note: Input signals are classified into the following groups. Make the setting so that the consecutive channels (ch and ch for example) are assigned the input signal categorized in the same group. Group : Thermocouple ( kinds), 50mV Group : Pt00. JPt00, Ni00, Cu50, Pt50 Group : 500mV Group : 5V, 05V Input signals can be arbitrarily selected for channels and and and 6. Item Scope of supply Quantity Main unit Panel mounting bracket CDROM (PC software and Instruction manual) Noise filter for power cable Option Item Type Specifications Shunt resistor for DC current input PHZP00 0Ω±0.% PC loader communication cable PHZP0 With USB A and USB minib Connector CDROM (PC software and instruction manual) PHZP50 PC card adapter for Compact flash PHZP050 Maker : Sandisk Compact flash (5MB) PHZP05 Note : Windows, Excel and Internet Explorer are registered trademarks of Microsoft Corporation. Note : SanDisk compact flash is a trademark of SanDisk. Note : PC series are registered trademarks of NEC Corp. Note : MODBUS is the registered trademark of AEG Schneider Autmation International. Note 5: Netscape is the registered trademark of Netscape Communication Corp. Note 6: Mozilla Firefox is the registered trademark of Mozilla Foundation. International Sales Div. Sales Group Gate City Ohsaki, East Tower,, Osaki chome, Shinagawaku, Tokyo 00, Japan Phone: 55, Fax: Information in this catalog is subject to change without notice. Printed in Japan 0/0FOLS

Saved Data playback Saved data in Memory card can be easily called out and played back on display

Saved Data playback Saved data in Memory card can be easily called out and played back on display Paperless Recorder Type:PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played

More information

PAPERLESS RECORDER SPECIFICATIONS PHF DATA SHEET. Input system. EDS10-77d

PAPERLESS RECORDER SPECIFICATIONS PHF DATA SHEET. Input system. EDS10-77d PAPERLESS RECORDER DATA SHEET PHF This is a paperless recorder that displays measured data on the LCD in real time and stores data in CompactFlash. The type of input such as thermocouple, resistance bulb,

More information

PAPERLESS RECORDER. Specifications Sheet No.SPEC-1137E (1st Edition)

PAPERLESS RECORDER. Specifications Sheet No.SPEC-1137E (1st Edition) Specifications Sheet No.SPEC-7E (st Edition) VM600 PAPERLESS RECORDER OUTLINE This is a paperless recorder that displays measured data on the LCD in real time and stores data in CompactFlash. The type

More information

Paperless Recorder VGR-B100. Series

Paperless Recorder VGR-B100. Series Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch

More information

PAPERLESS RECORDER OUTLINE FEATURES SPECIFICATIONS. Easy operation with touch panel providing an intuitive user interface

PAPERLESS RECORDER OUTLINE FEATURES SPECIFICATIONS. Easy operation with touch panel providing an intuitive user interface Specifications Sheet No.SPEC-42E (st Edition) M7000A PAPERLESS RECORDER OUTLINE The M7000A is a paperless recorder that displays measured data on the LCD in real time and stores data in the SD memory card.

More information

Type : PHF INP-TN1PHFQR-E

Type : PHF INP-TN1PHFQR-E Quick Reference PAPERLESS RECORDER Type : PHF INP-TN1PHFQR-E Head office Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fesys.co.jp/eng Instrumentation

More information

ARF100 Paperless Recorder

ARF100 Paperless Recorder No. CP-SS-1846E ARF100 Paperless Recorder The ARF100 Paperless Recorder features a highly visible 5.6-inch TFT color LCD, incorporates advanced functions, is easy to use, and is network-compatible. A sampling

More information

Technical Information

Technical Information Technical Information TI 04L41B01-02E DAQSTATION DXAdvanced (DX1000/DX2000) Functions Overview TI 04L41B01-02E Copyright Oct. 2005 1st Edition Nov. 2005 Contents Contents... 2 Foreword... 6 1 Overview

More information

PARAMETER LOADER FOR PAPERLESS RECORDER

PARAMETER LOADER FOR PAPERLESS RECORDER Instruction Manual PARAMETER LOADER FOR PAPERLESS RECORDER TYPE: PHL INP-TN513995-E WARNING If an error or improper operation occurs in our product, or customer-made programs should be found defective,

More information

Compact data logger offering best-in-class noise resistance and communication function

Compact data logger offering best-in-class noise resistance and communication function T M Portable Data Station XL100 Series Compact data logger offering best-in-class noise resistance and communication function A world s first in measuring instruments! To obtain IPv6 Ready Logo Phase-1

More information

ARF200. Paperless Recorder Advanced Recorder

ARF200. Paperless Recorder Advanced Recorder No. CP-SS-1871E ARF200 Paperless Recorder Advanced Recorder Overview The ARF200 Paperless Recorder adopts a highly visible 12.1-inch TFT color LCD, incorporates advanced functions, is easy to use, and

More information

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE Paperless Recording System PAPERLESS RECORDER (selectable input modules) MODEL & SUFFIX CODE SELECTION MODEL 144 (5.67) MODEL LANGUAGE E : English N : Japanese POWER INPUT M2: 100 240V AC R : 24V DC A

More information

Type : PHF. INP-TN1PHFQRc-E

Type : PHF. INP-TN1PHFQRc-E Quick Reference PAPERLESS RECORDER Type : PHF INP-TN1PHFQRc-E International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com

More information

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal

More information

Instruction Manual PAPERLESS RECORDER TYPE: PHU INP-TN1PHU-E

Instruction Manual PAPERLESS RECORDER TYPE: PHU INP-TN1PHU-E Instruction Manual PAPERLESS RECORDER TYPE: PHU PREFACE Thank you for your purchasing Fuji Paperless Recorder (Type: PHU). Read this instruction manual carefully to ensure correct installation, operation

More information

User s Manual RD-MV1000/RD-MV2000 M st Edition

User s Manual RD-MV1000/RD-MV2000 M st Edition User s Manual RD-MV1000/RD-MV2000 1st Edition How to Use This Manual Content Summary This user s manual consists of the chapters listed below. For information about the communication features and the accompanying

More information

Compact Controller M CC-M

Compact Controller M CC-M Fuji Instrumentation & Control Fuji Digital Controller Compact Controller M ECNO:1127a FUJI Electric declares a multi-loop controller era The Compact Controller M is a multi-loop controller of a new era

More information

Enhanced communication

Enhanced communication PUM Series Multi-loop module type Temperature controller DATA SHEET Enhanced communication Module (PROFIBUS) [PUMCP] PUMCP PUMCP is a communication module, which connects module type temperature controller

More information

DATA VIEWER FOR PAPERLESS RECORDER

DATA VIEWER FOR PAPERLESS RECORDER Instruction Manual DATA VIEWER FOR PAPERLESS RECORDER TYPE: PHL / PHU / PHF INP-TN514013d-E WARNING If an error or improper operation occurs in our product, or customer-made programs should be found defective,

More information

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL820 midi Logger Built-in 5.7" TFT LCD Color Display Stand-alone or PCconnected operation 20 Analog Channels Standard, Expandable to 200 Input-to-output and channel-to-channel Isolation USB and Ethernet

More information

Instruction Manual PAPERLESS RECORDER TYPE: PHF. INP-TN1PHFc-E

Instruction Manual PAPERLESS RECORDER TYPE: PHF. INP-TN1PHFc-E Instruction Manual PAPERLESS RECORDER TYPE: PHF INP-TN1PHFc-E PREFACE Thank you for your purchasing Fuji Paperless Recorder (Type: PHF). Read this instruction manual carefully to ensure correct installation,

More information

PR Series Paperless Recorders

PR Series Paperless Recorders PR Series Paperless Recorders Head Office: Brainchild Electronic Co., Ltd. 209 Chongyang Road, Nangang Dist., Taipei 11573, Taiwan Tel: +886-2-2786-1299 Fax: +886-2-2786-1395 Website: www.brainchild.com.tw

More information

midi LOGGER GL840 Quick Start Guide GL840-UM-850

midi LOGGER GL840 Quick Start Guide GL840-UM-850 midi LOGGER GL840 Quick Start Guide 604849020 GL840-UM-850 Thank you for choose the midi LOGGER GL840. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour. GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and

More information

DATA VIEWER FOR PAPERLESS RECORDER

DATA VIEWER FOR PAPERLESS RECORDER Instruction Manual DATA VIEWER FOR PAPERLESS RECORDER TYPE: PHL / PHU / PHF INP-TN514013e-E WARNING If an error or improper operation occurs in our product, or customer-made programs should be found defective,

More information

BACnet Controller for General-purpose Building Applications

BACnet Controller for General-purpose Building Applications Specifications BACnet Controller for General-purpose Building Applications General Model WJ-1101 is the BACnet controller to be used for a wide range of building applications such as air-conditioning and

More information

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology! Now with Touch Screen Technology! PPS-1000 PPS-2000 PPS-3000 Product Overview The PPS Series is a major advance in the market for Paperless Videographic Data Recorders incorporating Touch Screen Technology

More information

PCPR01 Paperless Recorder

PCPR01 Paperless Recorder PCPR01 Paperless Recorder Up to 18 channels of universal input UP to 4 Alarm Output Relays With 150mA Power distribution output Communication type: RS485, Modbus RTU With a USB data transfer interface

More information

Fuji Instrumentation & Control

Fuji Instrumentation & Control Fuji Instrumentation & Control High Speed control-50ms sampling Morized Valve control (Position feed back/servo control) Dual Controller (Heat/Cool controller) High ccurcy-0.% Extensive number of I/O points

More information

8420/8421/ MEMORY HiLOGGER

8420/8421/ MEMORY HiLOGGER Data Loggers 2003 8420/8421/8422-01 A Complete Line-up of 8 to 32 Channel Models LAN Compatibility plus Simultaneous Display of Graphics and Data As demand for multiple-channel temperature recording for

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use. PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER midi LOGGER GL820 Quick Start Guide GL820-UM-851 Thank you for choose the midi LOGGER GL820. This

More information

midi LOGGER GL240 Quick Start Guide GL240-UM-852

midi LOGGER GL240 Quick Start Guide GL240-UM-852 midi LOGGER GL240 Quick Start Guide 604249022 GL240-UM-852 Thank you for choosing Graphtec midi LOGGER GL240. The Quick Start Guide is to assist with the basic operations. Please refer to the USER'S MANUAL

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020 USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

XL112, XL114 ポータブルデータロガ

XL112, XL114 ポータブルデータロガ User's Manual Introduction Thank you for purchasing our XL100 Portable Data Station/Portable Data Logger. This Quick Setup Manual briefly describes the key operations as well as setting examples of the

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL220 midi Logger Built-in 4.3" WQVGA TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor

More information

Color Printer Microjet Recorder Series

Color Printer Microjet Recorder Series Fuji Instrumentation & Control Color Printer Microjet Recorder Series ECNO:1005i A Revolution in Recorder Technology The microjet recorder is a revolutionary recorder, its ink jet color printer technology

More information

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 Vision OPLC V350-35-TRA22 Technical Specifications The Unitronics V350-35-TRA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, 2 PT100/TC and 1 HSC/Shaftencoder

More information

User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder

User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder User s Manual Model FX1002/FX1004/ FX1006/FX1008/FX1010/FX1012 FX1000 Paperless Recorder IM 04L21B01-01EN 4th Edition Introduction Thank you for purchasing the FX1002, FX1004, FX1006, FX1008, FX1010, or

More information

DATA LOGGER Series SELECTION GUIDE

DATA LOGGER Series SELECTION GUIDE DATA LOGGER Series SELECTION GUIDE 2 Choose from Hioki s extensive line of loggers that s right for your application HIOKI Logger For multichannel measurement and recording LR831-20 Page Memory HiLogger

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

midi LOGGER GL240 Quick Start Guide GL240-UM-850

midi LOGGER GL240 Quick Start Guide GL240-UM-850 midi LOGGER GL240 Quick Start Guide 604249020 GL240-UM-850 Thank you for choose the midi LOGGER GL240. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information

General Specifications

General Specifications General Specifications MVAdvanced MV1000/MV2000 GS 04Q01A01-01E OVERVIEW The MVAdvanced MV1000/MV2000 is a portable recorder that displays real-time measured data on a color LCD and saves data on a CompactFlash

More information

PARAMETER LOADER FOR PAPERLESS RECORDER

PARAMETER LOADER FOR PAPERLESS RECORDER Instruction Manual PARAMETER LOADER FOR PAPERLESS RECORDER TYPE: PHL / PHU / PHF INP-TN513995c-E WARNING If an error or improper operation occurs in our product, or customer-made programs should be found

More information

Simplified information where and how you want it.

Simplified information where and how you want it. ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator

More information

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC The midi LOGGER GL200 has evolved 10 channels compact data logger No only for temperature but also for voltage fluctuation measurement

More information

Web-enabled DAQ System

Web-enabled DAQ System 2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing

More information

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22 Samba PLC+HMI SM35-J-TA22 SM43-J-TA22 SM70-J-TA22 Technical Specifications Ordering Information Item SM35-J- TA22 PLC with Flat panel, Color touch display 3.5 SM43-J- TA22 PLC with Flat panel, Color touch

More information

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology!

Instrumentation PPS Series Videographic Data Recorders. PPS Series Videographic Data Recorders. Now with Touch Screen Technology! Now with Touch Screen Technology! PPS-1000 PPS-2000 PPS-3000 Product Overview The PPS Series is a major advance in the market for Paperless Videographic Data Recorders incorporating Touch Screen Technology

More information

MEMORY HiLOGGER LR Featuring USB flash drive support and improved accuracy

MEMORY HiLOGGER LR Featuring USB flash drive support and improved accuracy MEMORY HiLOGGER LR8431-20 MEMORY HiLOGGER 8430 Data Loggers Featuring USB flash drive support and improved accuracy Your Personal 10-channel Logger Real-time recording of up to 10ms/ sample data to USB

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-TA24/V350-J-TA24 Technical Specifications The Unitronics V350-35-TA24/V350-J-TA24 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

Setting New Heights in Data Recording

Setting New Heights in Data Recording Isolated/Universal Input, Standalone Multi-Channel Datalogger GL840-M / GL840-WV / Setting New Heights in Data Recording Flexible input system for wide array of applications Wireless LAN capability for

More information

User Manual. cmt-iv5 Startup Guide

User Manual. cmt-iv5 Startup Guide User Manual cmt-iv5 Startup Guide v 2.2 JAN 8, 2016 Table of Contents Chapter1. Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Ethernet port... 3 1.4. CR1225 battery... 3 1.5. Power connection...

More information

High-powered control system for sophisticated processes

High-powered control system for sophisticated processes High-powered control system for sophisticated processes regulation control recording visualization easy to use freely configurable integrated PLC telemaintenance network-compatible Gigabit-Ethernet Compact

More information

TDS-630. High Performance Easy Handling

TDS-630. High Performance Easy Handling TDS-630 High Performance Easy Handling High Speed and High Functionality achieved by enhancing Measurement Speed and Processing Function Repeated Measurements in 0.1 seconds per 1000 channels TML-LINK

More information

Control Panel CP600 CP651, CP651-WEB

Control Panel CP600 CP651, CP651-WEB DATA SHEET Control Panel CP600 CP651, CP651-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP551100R0001 CP651, control panel, TFT graphical display, single-touch screen, 10.4, Active

More information

Datum-Y Portable Data Station (XL100)

Datum-Y Portable Data Station (XL100) Specification Sheet Datum-Y Portable Data Station (XL100) CAUTION: Underlined Specification that is indicated by will be included by December 26, 2005. We will prepare upgrade file to version up your having

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

SV100 Video Recorder

SV100 Video Recorder SV100 Video Recorder SV100 Video Recorder The paperless recorder with a touch of genius Designed with the operator in mind The SV100 features the industry s brightest display and touch screen control.

More information

FUJI UG SERIES PROGRAMMABLE OPERATION DISPLAY USER S MANUAL. <Notes on Using UG221H- LE4, LR4> TYPE: UG221H-LE4 UG221H-LR4 FEH374

FUJI UG SERIES PROGRAMMABLE OPERATION DISPLAY USER S MANUAL. <Notes on Using UG221H- LE4, LR4> TYPE: UG221H-LE4 UG221H-LR4 FEH374 FUJI UG SERIES PROGRAMMABLE OPERATION DISPLAY USER S MANUAL TYPE: UG221H-LE4 UG221H-LR4 FEH374 Preface This manual explains the notes and the limits for using UG221H-LE(R)4.

More information

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

DISCONTINUED MODEL Replaced with Model MSRPAC-2005 Series PC RECORDER SOFTWARE PACKAGE MODEL MODEL & SUFFIX CODE SELECTION MODEL DISCONTINUED MODEL Replaced with Model MSRPAC-2005 Functions & Features Industrial recorder on Windows based PC MSR128-V3:

More information

GV-IP Decoder Box Plus User s Manual

GV-IP Decoder Box Plus User s Manual GV-IP Decoder Box Plus User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. DBPV10-UM-A 2015 GeoVision, Inc.

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

NF760 Batch Controller

NF760 Batch Controller NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

BACnet. b3810 Series Local Controllers

BACnet. b3810 Series Local Controllers BACnet b380 Series Local Controllers The Andover Continuum TM b380 series controllers are designed for control of Air Handling Units, Roof Top Units, and other mechanical plant equipment. 0 Features Choose

More information

, , MEMORY HiLOGGER

, , MEMORY HiLOGGER 8420-51, 8421-51, 8422-51MEMORY HiLOGGER Data Loggers Internal memory capacity is greatly increased four times that of previous models! New multi-channel loggers with enhanced noise immunity As demand

More information

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet) Instruction Manual PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet) TYPE: PHF INP-TN5A0072b-E Note: MODBUS is the registered trade mark of AEG Schneider Aumaion International. NOTICE 1. Exemption items

More information

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet OVERVIEW The DATAWATCH IX monitor offers an excellent graphical display and recording device for a box of its size. The compact panel mount unit offers four isolated or eight non-isolated high accuracy

More information

Control Panel CP600 CP635-FB, CP635-FW

Control Panel CP600 CP635-FB, CP635-FW DATA SHEET Control Panel CP600 CP635-FB, CP635-FW 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535110R6001 CP635-FB, control panel, TFT graphical display, single-touch projected Active

More information

Visit to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket

Visit   to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket Digalox DPM72MPN Instruction manual (Rev201809) Visit www.digalox.com to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket 1. Intended Use

More information

Control Panel CP600 CP635, CP635-B, CP635-WEB

Control Panel CP600 CP635, CP635-B, CP635-WEB DATA SHEET Control Panel CP600 CP635, CP635-B, CP635-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP535100R0001 CP635, control panel, TFT graphical display, single-touch screen,

More information

Integrated Recorder GX-1

Integrated Recorder GX-1 Everybody's problem: Accelerated product development. Our goal: Decreasing the period between data acquisition and data analysis. Our solution: For data recording systems, the. Fast Collection of Valuable

More information

PXR Series Advanced Self-Tuning Temperature and Process Controllers

PXR Series Advanced Self-Tuning Temperature and Process Controllers PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater

More information

User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000

User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000 User s Manual Model DX2004/DX2008/DX2010/DX2020/ DX2030/DX2040/DX2048 Daqstation DX2000 Yokogawa Electric Corporation IM 04L42B01-01E 8th Edition Introduction Thank you for purchasing the Daqstation DX2000

More information

Samba PLC+HMI SM35-J-RA22

Samba PLC+HMI SM35-J-RA22 Samba PLC+HMI SM35-J-RA22 SM43-J-RA22 Technical Specifications Ordering Information Item SM35-J-RA22 PLC with Flat panel, Color touch display 3.5 SM43-J-RA22 PLC with Flat panel, Color touch display 4.3

More information

RD2000, 5.6" display. All models shown smaller than actual size.

RD2000, 5.6 display. All models shown smaller than actual size. Paperless Recorders RD1000/RD2000/RD3000 Series RD1000, 4.3" display RD2000, 5.6" display RD3000, 12.1" display All models shown smaller than actual size. Color TFT Touch Screen Display: 4.3", 5.6" and

More information

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600-eCo CP604, CP604-B DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active

More information

Your Personal 10-channel Logger. MEMORY HiLOGGER LR8431. Featuring USB flash drive support and improved accuracy

Your Personal 10-channel Logger. MEMORY HiLOGGER LR8431. Featuring USB flash drive support and improved accuracy MEMORY HiLOGGER LR8431 Featuring USB flash drive support and improved accuracy Your Personal 10-channel Logger Real-time recording of up to 10ms/ sample data to USB or CF memory devices Small and light

More information

Technical Information

Technical Information Technical Information DAQSTATION DX100/DX200 Copyright Feb. 2000 2nd Edition Feb. 2000 2 Contents CONTENTS... 2 INTRODUCTION... 3 1 FEATURES... 3 2 OVERVIEW OF FUNCTIONS... 4 2.1 CONSTRUCTION...

More information

INPUT Input point Measuring cycle Input type Disconnection detection Input filter

INPUT Input point Measuring cycle Input type Disconnection detection Input filter 2 = TEMPERATURE CONTROLLER PAPERLESS RECORDER หน าจอเป น Touch Sceen 7-Inch LCD เก บข อม ลผ าน SD Card และ USB Memory ร บ Input เป น TC/RTD/DC Voltage/DC Current ร บ Input 6 Channel ช วงเวลาในการอ านส

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System

SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System SmartView 280 (SV280) SmartView 280 Multibank (SV280MB) 280 mm Paperless Data Acquisition System The SmartView 280 Paperless Data Acquisition System (SV280) provides a cost-effective upgrade from existing

More information

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere!   Toll Free Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard

More information

1210 TM /1040 TM. Features: V1210 Flat Panel. V1040 Classic Panel HMI PLC. Communication

1210 TM /1040 TM. Features: V1210 Flat Panel. V1040 Classic Panel HMI PLC. Communication Features: HMI Up to 1024 user-designed screens 500 images per application HMI graphs - color-code Trends Built-in alarm screens Text String Library - easy localization Memory and communication monitoring

More information

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-TRA22/V350-J-TRA22 Technical Specifications The Unitronics V350-35-TRA22/V350-J-TRA22 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

DATA LOGGER Series SELECTION GUIDE

DATA LOGGER Series SELECTION GUIDE DATA LOGGER Series SELECTION GUIDE 2 Choose from Hioki s extensive line of loggers that s right for your application. HIOKI Logger Search For multichannel measurement and recording Memory HiLogger series

More information

Programmable Display. Feel the difference in power of expression, speed and networking capability. 9027NE1

Programmable Display. Feel the difference in power of expression, speed and networking capability. 9027NE1 Programmable Display Feel the difference in power of expression, speed and networking capability. 9027NE1 Communication technology drives innovation in every industry. Our MONITOUCH programmable displays

More information

User friendly and easy to program

User friendly and easy to program New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric

More information

Andover ContinuumTM Infinet II

Andover ContinuumTM Infinet II Andover ContinuumTM Infinet II i2920 System Controllers The Andover Continuum Infinet II i2920 System Controller is designed to meet the needs of your most demanding control and monitoring applications

More information

Touch Panel Monitor UT3-B15 Series

Touch Panel Monitor UT3-B15 Series U S E R I N T E R F A C E S O L U T I O N S P R O D U C T I N F O R M A T I O N 5-inch XGA Dual Video Interface Touch Panel Monitor UT3-B5 Series No.-0093e Issued: April, 200 The UT3-B5 Series are touch

More information

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring:

Vision570 TM /560 TM. Color OPLC TM. Color Vision570 TM /560 TM Series Featuring: Vision570 TM /560 TM Color OPLC TM Color Vision570 TM /560 TM Series Featuring: HMI Up to 1024 user-designed screens 500 images per application HMI graphs color-code Trends Built-in alarm screens Text

More information

SILVER SERIES OPERATOR INTERFACE TERMINAL

SILVER SERIES OPERATOR INTERFACE TERMINAL SILVER SERIES OPERTOR INTERFCE TERMINL Watlow Offers the Silver Series Operator Interface Terminal to Give Your System an Easy-to-Use, Reliable, ffordable Interface The Silver Series is a rugged, touchscreen

More information