1 USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai Tele fax : ,Mobil : , Customer Care : tempsen@yahoo.com, solution@tempsendevices.net Website : Page 1
2 WHEN YOU RECEIVE THIS INSTRUMENT... Thank you for purchasing the TEMPSEN DEVICES, TPLR-96 MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER. Please read the instruction manual carefully and use the instrument correctly. TEMPSEN DEVICES assumes no liability to any party for any loss or damage, direct or indirect, caused by the use or any unpredictable defect of the product. Cleaning of the front panel should be limited to wiping lightly with a dry cloth. Check that all of the following items are present. Paperless Recorder Range Input Type Output indication Communication interface A pair of mounting bracket Operating Voltage Serial link cable between Recorder& PC Output. PEN DRIVE use after antivirus scanning INSTALLATION Installation Location Install the control panel in a location that meets the following criteria. (1) Little or no mechanical vibration. (2) No corrosive gases. (3) Minimal temperature fluctuations and near normal temperature. (4) Not directly subject to radiant heat. (5) Not subject to strong electromagnetic field. (6) No direct exposure to water. WIRING Wiring precautions While wiring take the following precautions. (1) Field wiring to the instrument, should be placed so as to avoid blocking the air flow, yet Provide a suitable service loop to allow easy removal of unit with wiring attached. (2) Wires should be tied to maintain an order in the event they must be disconnected for Any reason. (3) For connecting the wire to the terminals, we recommend use of crimp terminal lugs with Insulated sleeves. (4) Route the input circuit wiring away as possible from the power and ground circuits to avoid Noise pickup. (5) Use proper-shielded wire to avoid electromagnetic interference. Page 2
3 SPECIFICATION OF TOUCH SCREEN PROCESS DATA LOGGER : General Input Resolution: 0.1% of full scale. Input Channels: 8 or 16 channel direct universal input. Measurement Rate: 4 channels per second on all direct input channels Internal Temperature Reference : 0 to 60 C Analog Inputs DC Voltage: 0-5 VDC with accuracy 0.1%. DC Current: 4-20mA, 0-20mA,Accuracy: +/-0.1% with built in shunt. Thermocouple Resolution: 1 C or optional 0.1 C Reference junction compensation: Yes Type Range ( C) Accuracy ( C) J -200 to -100 C +/-2.5 C -100 to 1200 C +/- 1.5 C K -270 to -100 C +/- 2.5 C -100 to 1372 C +/- 1.5 C T -270 to -100 C +/- 2.5 C -100 to 400 C +/- 1.5 C E -270 to -100 C +/- 2.5 C -100 to 1000 C +/- 1.5 C N -270 to -100 C +/- 2.5 C -100 to 1300 C +/- 1.5 C S -50 to 1768 C +/- 3 C B 0 to 1820 C +/- 4 C RTD Base Accuracy: 0.2% or 0.5 C (1 F).Resolution: 0.1 C 2 or 3 wire connection. Cable compensation to +50 ohm. Open and short circuit detection. Type Range C Accuracy ( C) 100 ohm Plt to 400 C +/- 0.2 C 1000 ohms 0 to 50 C +/- 0.2 C (optional Fixed Input only) Recording Recording Rates: User programmable from 1 sample per second to 1 sample every 10 hours Data Format:.Txt file; can be easily open able by variety of softwares. Data Storage Capacity:512 kb internal memory and this data can be Easily moved to memory stick connected to USB Port. Data Scaling and statistics : By PC Software Communication Specification Communication Output : RS 232 (or) RS 485 (or) USB (or) Ethernet (TCP/IP) Optional Advanced communication function provides high accuracy and stable multi-channel analog data sampling function to host computer. Also provides direct communication port to dot matrix printer and USB 2.0 pen drive option in the front panel of the Paperless Recorder. Page 3
4 GPRS with SMS and Mail : Optional SMS : 5 Mobile Numbers with Low & High Alarm SMS After 30 minutes 3 mail ID with Manual/ Auto mail Every day 12 AM Time Duration 1 hour per data Power Requirements: 100 to 240 VAC, 50/60Hz. 20 VA max. Optional 24 VDC Power Fail Protection Programmed parameters stored in non-volatile memory. Clock battery backed. Clock battery to be replaced once in 5Years, one 3V Lithium cell easily replaceable. Transmitter Power supply Output: Optional isolated 24Vdc@120mA output Input / Output Relay Output : 2 relay outputs, (normally open, Close & pole contacts) rated at A or 5Amp Max.Additional relay outputs (optional) : 12 Relay card; separate DIN rail Mounting Card interfaced with RS-232 or RS-485 interface with this unit Memory specification Internal memory: 20,000 Reading per channel. The data logger consists of internal memory storage capacity of above specified range provides a wide range of application in data storage for all channels individually Recording data on storage media Using the Setup menu, the user can log the data in internal memory. If this memory is full the logged data can be transferred to external storage media connected on USB Port. Record rate 8 channel 16 channel 1 Sec 9 Hrs 4.5 Hrs 10 Sec 90Hrs 45 Hrs 1 min 540 Hrs 270 Hrs 10 min 5400 Hrs 2700 Hrs The above table shows the number of maximum readings can be stored internal memory by changing record time After the above prescribed time the data must be transferred to USB storage media so as internal memory get free to store the new readings. Display Type: Color Active Matrix TFT Liquid Crystal Display Size: 3.5 inch diagonal, Resolution: 320 (W) x 240 (H) pixels Interface: Resistive analog touch screen control Display Modes: Graphic trending (horizontal), Bar Graphs( Vertical ) Digital Readout (Single or multi-channel), Alarms and event log settable. Historical trends: In PC Software. Display Windows: Time/Date, Graphics (bars, large digital, graph) Disk Status, System Status, Menu Button Bar, Alarms/ events Page 4
5 PC Based Software External PC software the user is able to manipulate the graph to make it easy to see interaction between recorded channels, or change the Color schemes, expand, compress, zoom and print. The same analysis tool used for multi-channel graph and used to scroll through data Optional : FDA Title 21 CFR Part 11 Compliant Software & Web server Based Software Safety and Environmental Operating Range: 0 C to 60 C, 10% to 90% RH non-condensing Dimension: Bezel dimension -110(W) x 100(H) x 15mm above panel. Unit dimension : 110 x 100 x 150 mm depth. Panel Cut out : 92 x 92 mm Protection : IP65 for front bezel when mounted in panel. Safety : Meets the requirements of EN when installed in accordance with the instructions in the Manual. UL and c UL : Pending EMC : Meets the requirements of EN61326 and CE directive 89/336/EEC & EN12830 Weight : Approximately 1.5 kg Recorder Dimensions Panel Cut out Page 5
6 OPERATING PARAMETER SETTING Switch ON the device, the following display will show the channel readings. It will take a few seconds. CONFIGURATION SETTING Click CONFIG in the display, Enter the password to progress into the Setting Screen. Page 6
7 After entering the password, the setting screen will be displayed as shown below TIME & DATE SETTINGS In Setting -> SET Real Time Clock, Set the real time & date details. Click OK to save the settings. Page 7
8 LOG TIME SETTINGS In Setting -> SET Log Time, Set the Log Time Of The Logger. Click Ok to save the settings. Page 8
9 CHANNEL PARAMETER SETTINGS In Setting -> SET Channel Parameters, Select the Alarm Range, Offset, Decimal, Sensor and Channels. ALARM : Set the alarm range from the specified values. Low : -999 High : 9999 RANGE : OFFSET : DECIMAL : Set the range with respect to the Sensor type specification.(ref PAGE NO:3) Set the offset range from -999 to 999, Default set 0 Set the decimal point from 0 to 3 for Linear Inputs only ALARM INDICATION STATUS Once the alarm is ON the acknowledgement ( ACK) shows in SCAN Key Alarm Status Normal High Low Display Color : BLACK : RED : BLUE Page 9
10 PASSWORD SETTINGS In Setting -> Click SET Password, this feature is used to change password of the user. COPY MEMORY : Insert an USB 2.0 drive in the front panel of the Logger. In Setting -> Click COPY Memory, this feature is used to copy the Logger memory in to the Pen Drive. Page 10
11 If USB 2.0 drive is not inserted in the drive, an error screen, PEN DRIVE PROBLEM!!! Will be displayed. ERASE : To clear the entire data from the Logger memory permanently, In Setting -> ERASE ALL!! Page 11
12 PRINT MEMORY : Insert an Ink jet printer through the PRINTER PORT provided in the back panel of Logger. In Setting -> Click PRINT Memory, the entire memory will be printed. SCAN : After completing all the Settings, Click HOME icon in the Setting screen. Click SCAN icon, to display the channel readings individually. Page 12
13 ID NUMBER : In Setting -> ID NUMBER SETTING for Multi Logger Software TERMINAL DETAILS: Input Terminal Communication port Printer Port Power Supply High & Low Alarm Page 13
14 DATA LOGGING OFF Logging Off The Data Logger, Click HOME icon in the Setting screen In Setting ->DATA LOGGING OFF MAINTENANCE Basic troubleshooting procedure The following questions should be asked & appropriate action is to be taken to the negative answers. All major corrective action can be accomplished by replacing the basic unit. No special tools are Required except screwdriver & multi meter. 1) When you switching ON the unit check whether the display is showing anything? If yes then go For step 2. If no check for the power input connections, check whether the unit is getting proper supply at proper terminals. Connecting the supply to the wrong terminals may damage the unit permanently. 2) Check the display whether it shows the actual value properly. If yes follow step 3,if no check the sensor Input; check whether the sensor or input is connected at proper terminals in proper way (+ve & -ve polarity). If sensor is open or not connected then 999.9" will appear on display. 3) After connecting the sensor if the actual value shown is not proper then check the calibration is Correct according to the calibration constant table. In case if fault developed other than the above mentioned, contact TEMPSEN DEVICES, CHENNAI , TN, INDIA, Cell : , Phone : , solution@tempsendevices.net,tempsen@yahoo.com, web: Page 14
USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020
USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationLBVR1718. Description. Features channel paperless recorder
LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,
More informationF1000 User's Manual. (Version: V1.01)
(Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...
More informationDMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions
www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew
More informationDigital Indicator Solutions
Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display
More informationSX 6000 Paperless Recorder
SILVER AUTOMATION INSTRUMENTS HTTP://WWW.SILVERINSTRUMENTS.COM RUNYI GROUP SX 6000 Paperless Recorder Product Overview SX6000 Paperless Recorder color-screen paperless recorder has 16-channel universal
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationPanelView Plus/VersaView CE Terminals and Display Modules
Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3
More informationTemperature/Process Controllers Manual
3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features
More informationTempco Instruction Manual
Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed
More informationPaperless Recorder. User s Manual KT200R IMA22-CP01
Paperless Recorder User s Manual KT200R IMA22-CP01 Foreword Thank you for purchasing our paperless recorder! This manual is about the functions, settings, wiring methods, methods of operation, failure
More information1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...
.6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04
More informationConductive Level Controller
Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment
More informationPM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features
PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationMicrocontroller Based 8 CHANNEL Temperature/Process DATA LOGGER (Product Code 8.7 to 8.9)
Microcontroller Based 8 CHANNEL Temperature/Process DATA LOGGER (Product Code 8.7 to 8.9) DATALOG-80 PC Software Model Wise Description: Sr. No Model Product Description (X = No. of channel ) 8.7 DATALOG
More informationMulti-instrument Communication, MIC-2 MKII DIN Quick Start Guide
Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications
More informationDual channel temperature logger with two voltage inputs 0-5V Instruction Manual
LOGGER S0541 Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual Instruction Manual for use of S0541 logger Instrument is designed for measurement and record of temperature
More informationScanner 2000 Steam Mass Flow Transmitter
3352051/2 IM-P335-24 MI Issue 2 Scanner 2000 Steam Mass Flow Transmitter Installation and Maintenance Instructions 1. Safety information 2. Mechanical installation 3. Configuring software 4. Wiring procedures
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationSamba PLC+HMI SM35-J-RA22
Samba PLC+HMI SM35-J-RA22 SM43-J-RA22 Technical Specifications Ordering Information Item SM35-J-RA22 PLC with Flat panel, Color touch display 3.5 SM43-J-RA22 PLC with Flat panel, Color touch display 4.3
More information7511 / / / 711 / / 731 / Preset 27
22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer
More informationOperation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter
Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE
More informationOperating Manual. Dynisco /8 DIN Indicator Concise Product Manual
Dynisco 1490 1/8 DIN Indicator Concise Product Manual 59476-9 Operating Manual -1- CAUTION: Installation should be only performed by technically competent personnel. Local Regulations regarding electrical
More informationPower Meter PowerMonitor 500
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific
More informationMeter Scanner & Controller
Meter Scanner & Controller CHART http://192.168.1.200 wiseries Save Current Graph Min / Max Temp 48.0/21.0 C hpa 50 1200 100% P1 Process A1 Ambient P2 Sensor 2 A2 Sensor 2 P3 Process A3 Ambient P4 Process
More informationMulti-instrument Communication, MIC-2 MKII DIN Quick Start Guide
Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications
More informationSX90 Process Controller
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationThe Indicator with 3 Limit Contacts
A 1200 The Indicator with 3 Limit Contacts Format: Installation depth: 96x48 mm (1/8-DIN) 122 mm Description and Operating Manual ELOTECH Industrieelektronik GmbH Verbindungsstrasse 27 D 40723 HILDEN FON
More informationVAT series controller and transmitter. Manual
VAT series controller and transmitter Manual 1. General describe.. 2. Notice for use.. 1 1 3. Panel & connection introduce.. 2 4. Operate introduce.. 5. Application introduce. 6. Communication. 7. Specification..
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationESM H 77x35 DIN Size Heating Controller Digital, ON / OFF Temperature Controller
Internal Buzzer ESM- 3711-H 77x35 DIN Size Heating Controller ESM-3711-H 77 x 35 DIN Size Digital, ON / OFF Temperature Controller - 3 Digits display - PTC Input or, J type Thermocouple Input or, K type
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationDPR 100 A/B Analog Scales
DPR 100 A/B Analog Scales 0I-6030 8/95 Pen and Multipoint 100 mm Digital Recorders Specification and Technical Data Introduction The DPR 100 is a microprocessor based 100 mm (4 inch) strip chart recorder
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationDPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2
Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering
More informationthe Interactive Catalog
Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationComprehensive Modular Genset Controller
Inteligen Learn More Comprehensive Modular Genset Controller Brief Description The Inteligen is a comprehensive controller for single and multiple generating sets operating in standby or parallel to the
More informationInteliLite MRS17 Click Here to Learn More
InteliLite MRS17 Click Here to Learn More Comprehensive Genset Controller Brief Description The InteliLite is a cost effective controller for generator sets in stand-by and prime power applications. The
More informationMICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS
MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller /
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationExtruder Controls ExtruVision S
Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and
More informationGFC114. Low Power Flow Computer FEATURES
Low Power Flow Computer FEATURES l UNIVERSAL INPUT, 5 khz, CAN POWER THE l SIMPLIFIED MENUS AND PROGRAMMING l NO NEED OF AMPLIFIERS OR LINEARIZERS l SEVEN DIGIT RATE WITH PROGRAMMABLE DECIMAL PLACES l
More informationTU531, TU532 Terminal Unit
Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationColor Printer Microjet Recorder Series
Fuji Instrumentation & Control Color Printer Microjet Recorder Series ECNO:1005i A Revolution in Recorder Technology The microjet recorder is a revolutionary recorder, its ink jet color printer technology
More informationSaved Data playback Saved data in Memory card can be easily called out and played back on display
Paperless Recorder Type:PHF Long Term Record Data Saving 4years in Compact Flash (In case of using 512MB Compact Flash) Saved Data playback Saved data in Memory card can be easily called out and played
More information6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)
6ES7212-1BD30-0XB0 Page 1 Product data sheet 6ES7212-1BD30-0XB0 SIMATIC S7-1200, CPU 1212C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 0,5A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC
More informationVPINSTRUMENTS.COM VPFLOWSCOPE M. Your next step in gas flow measurement
VPINSTRUMENTS.COM VPFLOWSCOPE M Your next step in gas flow measurement The Internet of Things / industry 4.0 is rapidly transforming our world. Production becomes smart, intelligent and autonomous. Production
More information- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS
ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT
More informationNetwork Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1
No. CP-SS-1865E Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1 Overview Network Instrumentation Modules make optimal distributed
More informationAnalog Input/Output Modules
User s Manual Analog Input/Output Modules Addendum Manual No. :IM 34M06H11-01E Manual Title :Analog Input/Output Modules Edition :1st Edition With the adoption of the CE Marking conformance declaration
More informationItem SM35-J-TA22 SM43-J-TA22 SM70-J-TA22
Samba PLC+HMI SM35-J-TA22 SM43-J-TA22 SM70-J-TA22 Technical Specifications Ordering Information Item SM35-J- TA22 PLC with Flat panel, Color touch display 3.5 SM43-J- TA22 PLC with Flat panel, Color touch
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationPulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port
Viale Borri 231, 21100 Varese - Italy Pulse concentrator, 12 inputs, Contents Pages 1. Description - Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation - Connection... 2 5. General characteristics...
More informationLOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E
LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11
More informationUser Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer
User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer Model: 92000-01 THE STANDARD IN PRECISION MEASUREMENT Table of Contents Introduction... 3 Unpacking... 3 Initial Setup...3
More informationDATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet
OVERVIEW The DATAWATCH IX monitor offers an excellent graphical display and recording device for a box of its size. The compact panel mount unit offers four isolated or eight non-isolated high accuracy
More informationThe PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.
PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION
More informationTABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.
DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.
More informationJUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature
Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,
More informationINTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS
INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationHMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out
Characteristics 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out Main Range of product Product or component type Display size Display type Pixel resolution Touch panel Offer Sustainability
More informationPTU300 Combined Pressure, Humidity and Temperature Transmitter
PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface
More informationKOBOLD TDA Series Digital Temperature Transmitter
KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com
More informationDisplay. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory
Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationManual of Electrical Installation for Pressure Probes KS and KS-SIL2 series
Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series GEFRAN SAFETY GUARANTEE Code 8594A Edition 2/204 Contents. General precautions pag 2 2. Transmitters with amplified analog output
More informationTOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004
Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationGeneral information. Display. Supply voltage. Input current. Encoder supply. Output current
Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information
More information/8 DIN Universal Process Indicator
Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission
More informationStrip Chart Recorders Specification Sheet
4101C, 4101M 4102C, 4102M MODELS Continuous Pen Recording 1, 2, 3 or 4 Pens Multi-point Recording Providing 6 Colour traces High Visibility Display 4101C, 4101M Clear Analogue Scale 4102C, 4102M Large
More informationTF501, TF521 Terminal Bases
Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,
More informationPR Series Paperless Recorders
PR Series Paperless Recorders Head Office: Brainchild Electronic Co., Ltd. 209 Chongyang Road, Nangang Dist., Taipei 11573, Taiwan Tel: +886-2-2786-1299 Fax: +886-2-2786-1395 Website: www.brainchild.com.tw
More informationSORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.
www.sordselectric.com MA7200 Sensorless Vector AC Inverter Features and Benefits Sensorless Vector The MA7200 has precise speed and torque control for the most demanding system performance and simple set-up
More informationSafety Relay Unit (I/O Unit Type)
Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and
More informationUWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION
UWE-1707 SERIES CONTENTS ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. SPECIFICATIONS PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 2. INSTALLATION 3. ROUTINE OPERATION
More informationFEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code
LARGE DISPLAYS BCD CODE Series BDF LARGE DISPLAYS for parallel BCD code BDF-xx-BCD for parallel BCD code FEMA ELECTRÓNICA IDEAL SOLUTION to display numerical values at long distances, controlled by parallel
More informationEM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter
EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar
More informationSOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1
SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1 SAFETY INFORMATION l Read the following safety information carefully before attempting to operate
More informationZenith DS9000 Dispensing System
Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field
More informationSynergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014
Upgrading a VersaTenn III controller with the Synergy Micro 2 Controller Introduction Synergy Controller is Tidal Engineering s line of Environmental l Test Chamber Controllers which and are designed to
More informationABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS
Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary
More informationPU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance
PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More informationFEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)
COUNTERS for IMPULSES Series MAG983-X COUNTERS for IMPULSE signals FEMA ELECTRÓNICA MAG983-1 MAG983-2 MAG983-3 MAG983-4 IDEAL SOLUTION for impulse counting applications where the operator has no access
More informationTRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationThe Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input
More informationMicro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges
Digital 10A Micro-Ohmmeters Models 6240 & 6250 Measure low resistance with high accuracy Selectable test current and resistance ranges 0.1µΩ resolution Simple one button press-to-start operation Software
More informationMRC 7000 Proven Recording Reliability that Became the Industry Standard!
Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables
More informationMMT330 Series Moisture and Temperature Transmitters for Oil
MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala
More informationGeneral information. Display. Supply voltage
Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product
More informationWARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.
55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger
More informationmark150s mark150/485s DDC controllers Summary
mark150s mark150/485s DDC controllers Summary DDC (Direct digital control) controller mark150s and mark150/485s are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They
More information