HDRF BRIDGE. v User Guide

Size: px
Start display at page:

Download "HDRF BRIDGE. v User Guide"

Transcription

1 HDRF BRIDGE v User Guide

2 CONTENTS 1 INTRODUCTION/INSTALLER QUICK SETUP PARTS AND ACCESSORIES HDRF BRIDGE FACTORY DEFAULTS... 5 A HDRF DEVICES AND RQ DEVICES INITIAL SETUP... 6 B HDRF BRIDGE CONNECTIONS... 6 C HDRF BRIDGE SETUP AND CONFIGURATION... 7 D STEPS CREATE AN HDRF NETWORK SPECIFICATIONS SAFETY INSTRUCTIONS REGULATORY COMPLIANCE APPENDIX A CONFIGURATION MENU SETTINGS APPENDIX B RQ MESSAGE FORMAT APPENDIX C RQ COMMANDS APPENDIX D UNSUPPORTED RQ COMMANDS APPENDIX E CONFIGURATION MENU SETTINGS Copyright 2014 Hunter Douglas Limited [ABN ] /14

3 1 INTRODUCTION The HDRF Bridge is an Automation gateway capable of converting RS232 serial commands from an Automation system into wireless RF commands to the HDR motor. A single HDRF Bridge will allow most automation systems to send UP/DOWN/STOP commands, as well as granular Move to positions for up to 255 individual motors, without requiring BUS cables or cords. (AC240 power still required to power the motor) Move to positions can be anywhere between 0% and 99% of the full open position in 1% increments, allowing very fine control of each individual blind. One HDR 4 Channel remote control can also be joined to the network allowing control of up to 15 motors. INSTALLER QUICK SETUP INSTRUCTIONS The instructions below are designed to enable the quick setup of the HDR motors to the bridge to allow an Automation system to begin communicating with the blinds. This setup does not include the addition of a remote control to control the blinds. See additional instructions in this guide to add a remote control. 1) Apply Power to the Bridge 2) Press the Network Button on the back of the HDR Bridge to enable pairing mode (the Bridge will flash yellow indefinitely) 3) Ensure all blinds/motors are installed and have power applied to the blind motors. (press either of the two buttons on the motor head to ensure the blind is powered) The blind should move momentarily to confirm. 4) Set Limits on each motor from the motor head. a. Press and Hold one of the outer buttons on the motor head and hold until the desired height of the bottom bar is achieved. b. To set the limit press and HOLD the centre button followed by the outer button together for approximately 15 seconds or until the centre button flashes. c. Set the other limit by following the same process above, but use the opposite outer button to the one in step A. d. To Change motor direction, Press and HOLD the two outer buttons on the motor head for approximately 20 seconds or until the centre light flashes. e. To clear all Limits and motor direction Press and Hold the CENTRE button for approximately 20 seconds. 5) To add the motor to the HDRF Bridge, once limits are set, Triple press the centre button (3 quick presses in less than 2 seconds) 6) The motor will JOG after 30 seconds to indicate it has joined the HDRF Bridge 7) Continue on to all other motors to be joined, following the steps above to set limits and add to the HDRF Bridge 8) Once all motors have been added, press the Network button on the back of the HDRF Bridge to stop the invitation mode (Yellow light will stop flashing) The HDRF Bridge can now be connected to the automation system and commands can be sent following the detailed instructions in this guide. 3

4 2 PARTS AND ACCESSORIES INCLUDED: HDRF Bridge. HDRF Antenna 2.4 GHz (onboard). External power supply 5 volt DC, 1A USB to Mini-B cable, 91cm (for external power supply). USAGE: Indoor Use in Dry Locations Only. NOT INCLUDED: SUITE remote. PC computer. RS-232 serial cable. FRONT LED USB PORT: The USB port is only for power, not data. Use only the 5 volt DC external power supply provided. BACK 4

5 3 HDRF BRIDGE FACTORY DEFAULTS Version Power Up Baud rate Flow Control Echo received characters End-of-line sequence Flip position when using RQ RQ Address (as shown on the bottom of the plastic case) Observe the HDRF Bridge LED for initialisation blink during power-up: 1 Blue N1 Xon/Xoff Off CR (carriage return) Yes BSB (may be reassigned) DEFINITIONS HDRF Bridge ACTION RESULTS Hub Device Jog Once Jog Twice Join a Network While Network Invite is active on the SUITE remote and the HDRF Bridge: Plug in each HDRF motor. Plug in each HDRF Receiver to a powered HDRF motor. IMPORTANT:The HDRF Bridge is always the Hub Device in an HDRF network. No other device can be the Hub Device. Device moves a short distance in one direction. Device moves a short distance in one direction,then moves a short distance in the opposite direction. Device jogs once to indicate the HDRF or RQ device successfully joined the network. Network Button * Triple press within 1 second A reset that clears network information.theyellow LED blinks twice,then the Blue LED blinks twice (indicates the HDRF Bridge is a Hub Device). A serial string with the version number is sent to the PC or automation system. Single press Press and hold for 10 seconds, until Yellow LED blinks once, then release. Starts or stops Network Invite.Use only when the Yellow LED is off, and you want to join a SUITE remote or other HDRF devices to the HDRF network. The Yellow LED flashes indefinitely. Single-press the Network Button again to turn off Network Invite (Yellow LED stops flashing). A partial reset that resets the Baud Rate and Terminal Emulator settings for the HDRF Bridge. Reset Button * Singlepress A full reset of the HDRF Bridge to factory default. The Blue LED blinks twice to indicate the HDRF Bridge is a Hub Device. A serial string with the version number is sent to the PC or automation system. Network Invite Network Search Press Network Button on HDRF Bridge to enable or disable Network Invite. SUITE remote: press the STOP button. Apply power to an HDRF device and the device will search for a network to join. The time frame while the Hub Device allows other HDRF devices to join the network. HDRF Bridge: Yellow LED flashes indefinitely. SUITE Remote: Green LED flashes for 60 seconds. HDRF motors and HDRF to HDQ Receivers will become a Hub Device and create their own network, if no other networks are found in up to 3 minutes. SUITE remotes and the RF Switch Transmitters only join existing networks. The HDRF Bridge is always the Hub Device and never performs a network search. * If you are in the Configuration Menu, you must exit the menu before pressing the Network Button or the Reset Button. 5

6 A HDRF DEVICES AND RQ DEVICES INITIAL SETUP The HDRF Bridge communicates with all HDRF devices as well as RQ motor controls or RQ motors that are connected by HDQ to HDRF Receivers. HDRF MOTORS AND REMOTES An HDRF Motor should be in the following state before joining to a network: Limits set, network information cleared, then unplugged. 6 NOTE: Limits can be set, cleared, and adjusted on an HDRF motor after it joins the network by using the motor head buttons or a SUITE remote. SUITE Remote at factory default and asleep. For details about using a SUITE remote in an HDRF network, see the Hunter Douglas M40/50RF System installer guide. RQ DEVICES (MOTORS AND MOTOR CONTROLS) CONNECTED TO HDRF TO HDQ TRANSCEIVER Prepare RQ devices for inclusion into an HDRF network, but do not plug in the HDRF to RQ Receiver yet. 1. The RQ device must be in the following state before connecting to an HDRF to RQ Receiver: a. Factory Default all options set to factory default. b. Limits set: i. If RQ control, limits on the motor being controlled must be set and the control calibrated. ii. If RQ motor, the limits must be set. 2. Follow the setup instructions included with RQ to HDRF Receiver Install Guide. 3. The RQ device motor or motor control must be powered up. The RQ to HDRF Receiver will be connected in a later step. An RQ motor control must have a motor connected to provide feedback (jogs), as an HDRF network is set up. B HDRF BRIDGE CONNECTIONS HARDWARE REQUIREMENTS HDRF Bridge (with 5 volt DC power supply and USB to Mini-B cable). PC computer or laptop with DB-9 style (DE-9) serial port, or USB port for a USB Serial Adaptor cable. o Terminal program for the PC, such as HyperTerminal or Tera Term. Do not use SuperTerm. o RS-232 male to female cable or USB Serial Adaptor cable (USB with DB-9 style male connector). OPTIONAL: one SUITE remote provides an additional method of motor administration and control for up to 15 motors that are in the HDRF network. TERMINAL EMULATOR SETTINGS NOTE: these settings are for HyperTerminal. Other terminal emulators may require Local Echo ON. Serial Port Settings: 9600 baud, 8 bits, 1 stop bit, no parity Flow Control: Software Xon/Xoff Local Echo: off Do not insert a linefeed after CR. RS-232 CABLE AND PINOUT Standard DB-9 style to DB-9 style RS-232 serial cables are used to connect a PC/laptop or automation system to the HDRF Bridge. See the illustration below.

7 NOTE: the CTS and RTS wires can be omitted when using Xon/Xoff flow control. HDRF BRIDGE C HDRF BRIDGE SETUP AND CONFIGURATION 1. Hook it up. a. Turn on the PC. Launch the terminal emulator program and create a new connection with the correct terminal emulator settings. b. Connect the RS-232 cable (or USB Serial Adaptor cable) from the PC to the RS-232 port on the HDRF Bridge. c. Connect the USB to Mini-B cable between the 5 volt DC external power supply and the HDRF Bridge. NOTE: The USB port on the HDRF Bridge is only for power, not data. 2. Apply power to the HDRF Bridge. a. Plug in the 5 volt DC external power supply to AC power. b. Observe the HDRF Bridge LED for initialization during power-up. Version blink: 1 Blue (version 1.0.0) c. The version report serial string is sent over the RS-232 connection to a terminal emulator or automation system:!bsbv (NOTE: BSB is the default RQ address of the HDRF Bridge). 3. Configure the HDRF Bridge. Use a terminal emulator to configure the HDRF Bridge and send commands to the RQ devices and/or HDRF devices in the network. For an explanation of the Configuration Menu settings shown below, see Appendix A. NOTE: HyperTerminal is used as the example below. Other terminal emulators may vary in the echo and line termination character settings. In the Terminal Emulator: a. Press Ctrl-C to launch the Configuration Menu. Only the last item in the Configuration Menu shows in the terminal emulator (HyperTerminal). To see all of the menu items, turn on the Echo and Linefeed characters using the next two steps. b. Press the 2 key. Sets Echo to on to see Rx characters on the screen. c. Press the 3 key. Sets the line termination character to CR+LF (carriage return and line feed). 7

8 Configuration Menu: d. OPTIONAL: change the Baud Rate. 1. Press the 1 key OR use an arrow key to select the Baud rate entry in the Configuration Menu, then press the Enter key. 2. In the Baud rate sub-menu, press the 1 2 or 3 key OR use an arrow key to select a different Baud rate, then press the Enter key. Baud rate sub-menu: 3. Change the Baud rate in the terminal emulator program on the PC to match the HDRF Bridge. 4. Power-cycle the HDRF Bridge. NOTE: the Baud rate does not change until power is turned off, then turned on. To return to the Configuration Menu from the Baud rate sub-menu: Press the 0 key OR use an arrow key to select the Up entry, then press the Enter key. e. OPTIONAL: change other settings, by selecting the item in the Configuration Menu, and making a selection in the sub-menu that appears. f. Exit the Configuration Menu: Press the 0 key or use an arrow key to select the Exit Configuration then press the Enter key. D STEPS CREATE AN HDRF NETWORK IMPORTANT: A SUITE remote is OPTIONAL. A SUITE remote (Setup Mode) can Toggle Motor Direction and Set/Adjust/Clear Limits for 15 HDRF motors. If no SUITE remote is in the network, the Toggle Motor Direction and Set/Adjust/Clear Limits can be performed using the head buttons on an HDRF motor. A SUITE remote cannot Set/Adjust/Clear Limits on RQ motors or RQ motor controls that are connected to the HDQ to HDRF Receiver. A SUITE remote in User Mode can control all motors in a network? 1. Exit from the Configuration Menu if it is showing in the terminal emulator. 2. Verify that no devices are currently joined to the HDRF network. a. In the terminal emulator, press Ctrl-T to show the Device List. b. If the Device List is empty, continue with Step 3. 8

9 Empty Device List: c. If the Device List contains devices, then triple-press (within 1 second) the Network Button on the HDRF Bridge. The Yellow LED blinks twice, then the Blue LED blinks twice. A serial string with the version number is sent to the PC or automation system. d. In the terminal emulator, press Ctrl-T to show the Device List, which should be empty. Exit the Ctrl-T screen by pressing Ctrl-C, then the O key. Continue with Step On the HDRF Bridge, start Network Invite by pressing the Network Button once. a. The Yellow LED is flashing (and remains flashing until the Network Button is pressed again). 4. ONLY IF USING A SUITE REMOTE join the remote to the network. a. Press the PRESET, UP, STOP, or DOWN button to wake up and initiate Network Search. Green PRESET LED is on solid. b. After a few seconds, the SUITE remote joins the HDRF network. The Group 1 LED is on solid, and the Red PRESET button is on solid. c. Press the Network Button on HDRF Bridge to turn off Network Invite. Yellow LED on the HDRF Bridge turns OFF. 5. ONLY IF USING A SUITE REMOTE join RF devices to the network. a. For the remainder of network setup, issue the Network Invite from the SUITE remote to join other RF devices to the network. Wake up the remote, then press and release the STOP button to initiate Network Invite. Remote: Green LED under PRESET flashes for up to 60 seconds while Network Invite is active. HDRF Bridge: Yellow LED also flashes to indicate Network Invite is active. b. Press the STOP button on the SUITE remote to toggle Network Invite ON and OFF. IMPORTANT: Network Invite on the SUITE remote turns OFF after 60 seconds. Make sure Network Invite is ON before joining devices to the network. NOTE: The first 15 motors that are joined can be administered from the SUITE remote. All networked devices are shown in the Device List of the HDRF Bridge and can be administered and controlled with the HDRF Bridge. 6. Make sure Network Invite is active on the SUITE remote (if used) and the HDRF Bridge. a. Apply power to each HDRF motor, and plug in an RQ to HDR Receiver into each RQ motor or RQ motor control, until all devices are joined to the network. b. Each device jogs when it joins the network, which normally happens within a few seconds. 7. If only using the HDRF Bridge (no remote), press the Network Button once to stop Network Invite. a. Yellow LED turns off. 9

10 8. In the terminal emulator, press Ctrl-T to show the Device List. Verify that all devices successfully joined the network. IMPORTANT The RQ address of each device is automatically reassigned a new 3-digit RQ address as it joins the network: 001, 002, 003, and so on. For the Type of device: 01 is a SUITE remote, and 06 is an HDRF motor or HDQ to HDRF Receiver (connected to an HDQ motor or HDQ motor control). The HDRF Bridge does not show in the Device List. Below is an example of a Device List with six devices one SUITE remote and five other devices. 9. Configure the HDRF network. a. Use the SUITE remote to configure the HDRF network (full configuration for HDRF motors, and only setting the PRESET position on motors using the RQ to HDRF Receiver), OR b. In the terminal emulator or automation system, use the RQ commands listed in Appendix C to configure the HDRF network. NOTE: Enter RQ commands into the terminal emulator while at the Device List screen (Ctrl-T). 15. END. 10 IMPORTANT: If you are not using a SUITE remote in the HDRF network, you must set limits on HDRF motors first, in order to use RQ commands from the terminal emulator to configure and control those motors. 10. If the HDRF Bridge is to be connected to an automation system after the HDRF network is set up, then you must reverse the Echo (On) and Line Termination character (CR+LF) that were turned on previously in the Configuration Menu from the terminal emulator. To reverse Echo (On) and Line Termination character (CR+LF) in the terminal emulator: a. Press Ctrl-C to enter the Configuration Menu. b. Press the 2 key. c. Press the 3 key. d. Press the 0 key to exit the Configuration Menu. 11. Verify that the Yellow LED on the HDRF Bridge is OFF. If the Yellow LED is flashing, press the Network Button once to turn the LED off. 12. Disconnect the PC from the HDRF Bridge. 13. Connect the automation system to the HDRF Bridge. 14. Put the SUITE remote into User Mode, for handoff to the customer.

11 4 SPECIFICATIONS No serviceable parts are included. Usage Power Indoor Use in Dry Locations Only. Ordinary Protection (not protected against harmful ingress of moisture). USB power draw from the USB 5VDC Power Supply: 5VDC 1A max (<0.1A typical) Frequency 2.4 GHz Operating Temperature Range +5 C to + 35 C (+41 F to + 95 F) Transportation and Storage Temperatures -18 C to + 49 C (0 F to +120 F) Maximum Altitude 4,115 m (13,500 ft) Weight HDRF Bridge: 0.12 kg (0.26 lb) HDRF Bridge: Dimensions Width: 96.7 mm (3.81in) Height: 96.7 mm (3.81in) Depth: 23.6 mm (0.93 in ) Listed Accessories Cleaning Instructions External USB 5VDC power supply. USB cable. HDRF Bridge: 1. Disconnect power. 2. Unplug cable and power cord. 3. Wipe the device s outside surface lightly with a clean, soft cloth dampened with water. Optional Remote Control: 1. Wipe the device s outside surface lightly with a clean, soft cloth dampened with water. 5 SAFETY INSTRUCTIONS WARNING: Important safety instructions. It is important for the safety of persons to follow these instructions. Save these instructions. Do not allow children to play with fixed controls. Keep remote controls away from children. Frequently examine the installation for imbalance and signs of wear or damage to cables. Do not use if repair or adjustment is necessary. Please instruct the Operator to disconnect the external power supply & remove the plug of the power supply cord of the external power supply from the AC Mains Outlet (or remove the wall-mount power supply from the AC Mains Outlet): please ensure that the Mains Outlet is easily accessible for this purpose. 11

12 6 REGULATORY COMPLIANCE This symbol means that this product complies with International Standard EN 55011: 2007 and AS/NZS 4268: APPENDIX A CONFIGURATION MENU SETTINGS Configuration Menu Entry 12 Default Setting Description 0. Exit Configuration n/a Exits the HDRF Bridge configuration menu. 1. Baud rate 9600 Choices: 9600, 19200, Bridge echoes Rx d characters off Choices: off = do not echo characters to the display. on = echo characters to the display. 3. Line termination character(s) CR Choices: CR = moves the cursor to the beginning of the same line. CR+LF = moves the cursor to the beginning of the next line. 4. Semicolon action Terminates command Choices: Terminates command = parses and transmits single commands each time a semicolon or CR is received. Separates commands = allows multiple commands to be received before processing. Commands are parsed and transmitted after a CR is received. 5. Flip position when using RQ Yes Choices: See NOTE 1 below. Yes = position reports from RF devices are flipped to match the position reporting scheme of RQ devices. No = position reports from RF devices are not flipped. 6. Pass Device Information Frame Never Choices: See NOTE 2 below. Never = do not transmit Device Information Frames over the serial interface. When using RF = transmit Device Information Frames over the serial interface when the last command received was an RF command and not an RQ command. Always = transmit Device Information Frames over the serial interface whenever one is received from an RF device. NOTE 1 a. By default, RQ devices report 99 percent when at the fully closed limit, and 0 percent when at the fully open limit. b. By default, RF devices report 0.0 percent when at the fully closed limit, and 99.9 percent when at the fully open limit. c. When the RQ protocol is used, the position is reported as two digits (0-99) from RQ devices that use the HDQ to HDR Receiver. d. When the RF protocol is used, the position is reported as two digits (0-99) from RQ devices, and as three digits ( ) from RF devices. NOTE 2 a. A Device Information Frame is an RF protocol message that contains detailed information about an RF device.

13 8 APPENDIX B RQ MESSAGE FORMAT An RQ message always begins with the Start Character! (a.k.a. Bang) and ends with the End Character ; (semicolon). There will always be an Address (3 ASCII characters) and a Command (1 ASCII character) as shown in the table below. In some cases, the Data field is a variable number of characters or no Data. A? (question mark) in the Data field signifies a query message. For Downlink messages, the End Character is ; or <CR> (both are treated the same). For Uplink messages, the End Character can be set using the HDRF Bridge Configuration Menu to be ; or <CR>. RQ Addressing is always three ASCII characters composed of only 0-9 and A-Z. For the case where an address is 000 the global command all RF devices networked to the HDRF Bridge are being addressed and for that reason, no device can have 000 as its RQ address. The HDRF Bridge is factory addressed at BSB. RQ devices are given random addresses from the factory (first character will be between C and Z ). Uplink Messages from the RF devices, relayed to the PC/automation system via the HDRF Bridge. Downlink Messages from the PC/automation system, relayed to the RF devices via the HDRF Bridge. The following is an example of a Downlink message from the PC/automation system to the HDRF Bridge requesting its version. The literal command string is!bsbv?; Start Character Address Command Data End Character! BSB v? ; Improperly formatted Downlink messages or message content that is out of range will cause the message to be discarded by the HDRF Bridge and an Uplink error message generated (!BSBU;). 13

14 The RQ commands and responses in the table below are valid when sent to the HDRF Bridge from a PC or automation system. BSB = the default RQ address of the HDRF Bridge. RQ (and A) 14 Data Description Example Response Notes 3 characters (0-9 or A-Z) Re-address the SUITE remote!001@rm1; RQ Address change report.!001@rm1; v? Report version!bsbv?;!bsbv ; v? Report version!002v?;!002v ; o none Move open c none Move close s none Stop i none Identify m r? destination* (00-99) Move to intermediate position (2 digit) Request 2 digit position now!002o;!000o;!002c;!000c;!002s;!000s;!002i;!000i;!002m23;!002r?; Motor moves to fully open. All motors move to fully Open. Motor moves to fully Closed. All motors move to fully Closed. Motor stops. All motors Stop. Motor jogs once. All motors jog once. SCENES: Scenes cannot be defined while the motor is moving. d scene s Define a scene!002dc23; d scene s here (where we h = set scene to are now) g scene s Execute scene d 9 APPENDIX C RQ COMMANDS scene s NS Clear a scene!002dch;!000dch;!002gc;!000gc;!002dcns;!000dcns; Motor moves to 23% away from reference. 2 digit position report if motor is stopped. For example:!002r23; If RQ Motor or standard motor/ RQ motor control: jogs twice and does not move to the scene. If RF motor: jogs twice, then jogs twice again, and does not move to the scene. Motor jogs twice. All motors jog twice. Motor goes to scene C. All motors go to scene C, if they are included in the scene. Motor jogs twice.** All motors jog twice.** This device s RQ address was changed from 001 to RM1. The HDRF Bridge s firmware version is This device s firmware version is NOTE: the SUITE remote will not report it s firmware version number.!000 is a Global All command.!000 is a Global All command.!000 is a Global All command. Used to identify which motor is assigned to an RQ address.!000 is a Global All command. Motor is stopped 23% away from reference. Motor is stopped 23% away from reference. Define Scene C at 23% away from reference for this motor. NOTE: By default, Scene 0 is used for the PRESET button on the SUITE remote. Scene is set at current, stopped position of motor(s).!000 is a Global All command. If motor is already at position for Scene C, or motor is not in Scene C, no movement happens.!000 is a Global All command. Do not act on scene C for this motor.**!000 is a Global All command. Clears scene C on all motors.** * 00 means at reference (for RQ, default = open), 99 means at limit away from reference (closed). The percentages can be flipped when using the Flip position option in the Configuration Menu of the HDRF Bridge. NOTE: positions may not be evenly spaced depending on method of lift and motor response to load. NOTE: 2 digit positions repeat the 1st digit as the 3rd digit to evenly space the fractional part. For example: 27% is converted to 27.2%. When a position is reported as 2 digits, the 3rd digit is ignored (not rounded). ** For RQ to HDRF Receiver product label = v1.5.0 and earlier / firmware = v and earlier the motor will jog once when a scene is cleared. For HDRF motors product label = v1.4.0 and earlier / firmware = v and earlier the motor does not jog and the scene is not cleared. s Scene number is one of 62 possible: from 0 to 9, A to Z, a to z

15 10 APPENDIX D UNSUPPORTED RQ COMMANDS These RQ commands are not supported when sent to an HDRF Bridge from a PC or automation system. BSB = the default RQ address of the HDRF Bridge.!BSBU; the U = undefined or invalid message. RQ Command Data Description Send Response Notes ~ ~ Global All 3 characters (0-9 or A-Z) Randomize the HDRF Bridge s RQ address Randomize the RQ address of all RQ devices (Global All) Randomize the RQ address of one RQ device Re-address all devices!bsb~;!bsbu; Not allowed.!000~;!bsbu; Not allowed.!002~;!bsbu; Not allowed.!000@aaa!bsbu; Illegal command. d - (minus sign) Clear all scenes!002d-;!bsbu; Currently not supported. M N? N R? destination ( ) 1-16 characters Move to intermediate position (3 digit) Request the HDRF Bridge s default name Assign a name to the HDRF Bridge Request 3 digit position now!002m237;!bsbn?;!bsbnrf_ bridge; Moves to 23.7% away from reference.!bsbu;!bsbu; Currently not supported. Not allowed. The name parameter is not supported on the HDRF Bridge or on RF devices networked to the HDRF Bridge. Not allowed. Cannot assign a name to the HDRF Bridge.!002R?; 3 digit position report if stopped. Currently not supported. V Global All? Report version!000v?;!bsbv ; The HDRF Bridge reports first... followed by version reports from several, but not all of the RF devices. NOTE: Not all RF devices report when using a Global All version request. The HDRF Bridge s firmware version is NOTE: the SUITE remote will not report it s firmware version number. 11 APPENDIX E CONFIGURATION MENU SETTINGS HDRF Commands entered using a terminal emulator are fully supported and contain commands that can be used to configure HDRF motors if no SUITE remote is used in the network, for example, Toggle Motor Direction and Set/ Clear/Adjust Limits. The syntax for HDRF Commands is significantly different than RQ Commands and is not documented here. If there is a need for HDRF Commands, contact Hunter Douglas Support for details. NOTE: If no SUITE remote is in the network, the motor configuration functions can be performed using the head buttons on the HDRF motor Disclaimer Information in this document is subject to change without notice. The manufacturer does not make any representations or warranties (implied or otherwise) regarding the accuracy and completeness of this document and shall in no event be liable for any loss of profit or any commercial damage, including but not limited to special, incidental, consequential, or other damage. All trademarks used herein are the property of their respective holders. 15

16

Installation & Operation

Installation & Operation LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon

More information

PowerView AC Motor. by LUXAFLEX WINDOW FASHIONS

PowerView AC Motor. by LUXAFLEX WINDOW FASHIONS PowerView AC Motor by LUXAFLEX WINDOW FASHIONS CONTENTS GETTING STARTED Getting Started... 1 Remote Control Overview... 2 Using Multiple remotes within a home (Copying Network ID)... 4 Programming Overview...

More information

Bluetooth RS-232 Dongle. User s Manual BTS-100

Bluetooth RS-232 Dongle. User s Manual BTS-100 Bluetooth RS-232 Dongle User s Manual BTS-100 Table of Contents 1. INTRODUCTION... 2 2. PHYSICAL DIAGRAM... 3 3. BLUETOOTH PAIRING AND CONNECTING... 4 4. RS-232 INSTALLATION... 10 5. HYPERTERMINAL SETTING

More information

May 2016 Version 1.2.7

May 2016 Version 1.2.7 May 2016 Version 1.2.7 2 Introduction Copyright Copyright 2016 4RF Limited. All rights reserved. This document is protected by copyright belonging to 4RF Limited and may not be reproduced or republished

More information

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1.

SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE. Manual No. D Revision Date: 08/2016 Control: 1. SERIES 4600 Ethernet Visual-Pager Display INSTALLATION and SPECIFICATION GUIDE Manual No. D4600-7010 Revision Date: 08/2016 Control: 1.0 Microframe Corporation 604 South 12th Street Local: 918-258-4839

More information

PowerView. Hub. by LUXAFLEX WINDOW FASHIONs

PowerView. Hub. by LUXAFLEX WINDOW FASHIONs PowerView Hub by LUXAFLEX WINDOW FASHIONs quick start guide Table of Contents Kit Contents...3 Connections... 4 Home Automation Integration... 10 Troubleshooting... 11 The PowerView Hub interfaces with

More information

SeriBox. antrax Datentechnik GmbH

SeriBox. antrax Datentechnik GmbH info@antrax.de SeriBox - Interface box with serial or USB interface - PC connection / Read IN and OUT signal information - 3 x INput (TTL level / floating contact) - 3 x OUTput (relay contact) Manual Firmware

More information

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

2001 by NEC America. All Rights Reserved. Printed in U.S.A. These instructions are customized for the CNet Modem V.90 k bps modem (P/N D) contained in the i Modem Kit P/N 9, i Modem Kit P/N 90B, and the i and 0i Modem Kit P/N 9. The modem connected to the system

More information

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL

ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL. 60101 www.electronicdisplays.com PRODUCT PART NUMBER : ED225MPC 2L N1-VERT-1001- KYN1 DESCRIPTION: Indoor 4 digit, 2.25 inch high, red LED, 2

More information

Figure 1: ZigBee Evaluation Kit (ZEK) Contents. Figure 2: ZigBee Adapter Zb-121 and Module Zb-21

Figure 1: ZigBee Evaluation Kit (ZEK) Contents. Figure 2: ZigBee Adapter Zb-121 and Module Zb-21 The ZigBee Evaluation Kit (ZEK) has been developed for evaluation of the ZigBee wireless solution from Amp ed RF. This demo kit utilizes Amp ed RF ZigBee Serial Adapter (AR Zb-121) board with embedded

More information

USB TO RS-232/RS-422/RS-485 ADAPTER

USB TO RS-232/RS-422/RS-485 ADAPTER USB TO RS-232/RS-422/RS-485 ADAPTER For Android User s Manual UTS-232AD / UTS-422AD / UTS-485AD Table of Contents Introduction...2 System Requirements...2 Features...2 Specifications...3 Install Application...4

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

MODEL 715AN QUADRATURE DEGREES COUNTER

MODEL 715AN QUADRATURE DEGREES COUNTER MODEL 715AN QUADRATURE DEGREES COUNTER DESIGN CONCEPTS INC 707 N. Lindenwood Olathe, Kansas 66062 PHONE: (913) 782-5672 FAX: (913) 782-5766 E-MAIL : info@dcimeters.com 0411 TABLE OF CONTENTS 2. Features

More information

HP 527 Dual Radio ac Unified Wired-WLAN Walljack

HP 527 Dual Radio ac Unified Wired-WLAN Walljack HP 527 Dual Radio 802.11ac Unified Wired-WLAN Walljack Installation Guide Part number: 5998-7087a Document version: 6W101-20150318 Legal and notice information Copyright 2015 Hewlett-Packard Development

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 75E Installation Guide January 003 - Ref: I75EE0303-1 Model AX3000/M75E The reproduction of this material, in part or whole, is strictly prohibited. For additional

More information

AUTOMATE ARC DRAPERY MOTOR

AUTOMATE ARC DRAPERY MOTOR AUTOMATE ARC DRAPERY MOTOR US: MTACRFDR-50KG AU: MT01-2101-069001 433 MHZ BI-DIRECTIONAL ELECTRONIC LIMIT FAVORITE POSITION LEVEL CONTROL SOFT TOUCH QUIET OPERATION SELECTABLE RPM AUTOMATE ARC drapery

More information

Matrix for HDMI 1.3 EXT-HDMI User Manual. Release A6

Matrix for HDMI 1.3 EXT-HDMI User Manual. Release A6 Matrix for HDMI 1.3 EXT-HDMI1.3-444 User Manual Release A6 4x4 Matrix for HDMI 1.3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow

More information

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

HDMV-Plus. Installation Manual

HDMV-Plus. Installation Manual HDMV-Plus 4-Port Full HD Multiviewer View four different HDMI video sources simultaneously on one screen with USB keyboard and mouse support. Installation Manual Made in the U.S.A. 1-800-AVI-21311 Table

More information

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A 8 Button RS232/IR Control Panel 500816 MuxLab Inc. 2016 94-000833-A / SE-000833-A SAFETY PRECAUTIONS To insure the best use from the product, please read all instructions carefully before using the device.

More information

MONARCH 9416 XL QUICK REFERENCE

MONARCH 9416 XL QUICK REFERENCE MONARCH 9416 XL QUICK REFERENCE This Quick Reference contains ribbon loading, supply loading, and general care, maintenance, and troubleshooting procedures for the 9416 XL Thermal Direct and 9416 XL Thermal

More information

SERIES 5100XXX8 INSTALLATION & SPECIFICATION GUIDE

SERIES 5100XXX8 INSTALLATION & SPECIFICATION GUIDE SERIES 5100XXX8 INSTALLATION & SPECIFICATION GUIDE Microframe Corporation 604 South 12th Street Local: 918-258-4839 Toll Free: Website: www.microframecorp.com E-mail: support@microframecorp.com Revision

More information

E600 VX01 Installation guide

E600 VX01 Installation guide E600 VX01 Installation guide illuminfx Dimensions 2007 Viso Systems ApS, Denmark All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing

More information

FA-2448 SIX POSITION Filter Wheel

FA-2448 SIX POSITION Filter Wheel 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com Operating Instructions Acton Research Corporation FA-2448 SIX POSITION Filter Wheel Rev. 3.05.17

More information

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual

EMC-1 TM. Ethernet Meterbus Converter. DIMENSIONS [inches (millimeters)] Installation and Operation Manual EMC-1 TM Ethernet Meterbus Converter Installation and Operation Manual DIMENSIONS [inches (millimeters)] 4.85 ( 123 ) For the most recent manual revisions, see the version at: www.morningstarcorp.com 3.37

More information

HDMI/HDBT 1x4 Splitter. Installation & Operation Manual. MuxLab Inc A / SE A

HDMI/HDBT 1x4 Splitter. Installation & Operation Manual. MuxLab Inc A / SE A 500424 MuxLab Inc. 2016 94-000808-A / SE-000808-A SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference.

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 55E Installation Guide February 2002 - Ref: I55EE0210-1 Model AX3000/M55E The reproduction of this material, in part or whole, is strictly prohibited. For

More information

MXHP-H500 (Hub) Owner s Manual v.1.0

MXHP-H500 (Hub) Owner s Manual v.1.0 MXHP-H500 (Hub) Owner s Manual v.1.0 MX-HomePro MXHP-H500 Owner s Manual 2016 Universal Remote Control, Inc. all rights reserved. The information in this manual is copyright protected. No part of this

More information

INTERPRETER CONTROL UNIT MODEL PL ICU 2 2 (2 INPUTS 2 OUTPUTS) INSTRUCTION MANUAL Technical Data Warranty Information

INTERPRETER CONTROL UNIT MODEL PL ICU 2 2 (2 INPUTS 2 OUTPUTS) INSTRUCTION MANUAL Technical Data Warranty Information INTERPRETER CONTROL UNIT MODEL PL ICU 2 2 (2 INPUTS 2 OUTPUTS) INSTRUCTION MANUAL Technical Data Warranty Information 2 INTERPRETER CONTROL UNIT - MODEL PL ICU 2 2 INSTRUCTION MANUAL Congratulations on

More information

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1000 Part No. 23624 OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1000 OV1000 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

HDMV. 4-Port Full HD Multiviewer View four different HDMI video sources simultaneously on one screen. Installation Manual

HDMV. 4-Port Full HD Multiviewer View four different HDMI video sources simultaneously on one screen. Installation Manual HDMV 4-Port Full HD Multiviewer View four different HDMI video sources simultaneously on one screen. Installation Manual Table of Contents TABLE OF CONTENTS AND TECHNICAL SPECIFICATIONS 2-3 INTRODUCTION

More information

USB Serial Converter

USB Serial Converter USB Serial Converter Copyright Statement No part of this publication may be reproduced in any form by any means without the prior written permission. Other trademarks or brand names mentioned herein are

More information

SERIES 5100 INSTALLATION & SPECIFICATION GUIDE

SERIES 5100 INSTALLATION & SPECIFICATION GUIDE SERIES 5100 INSTALLATION & SPECIFICATION GUIDE Microframe Corporation 604 South 12th Street Local: 918-258-4839 Toll Free: Website: www.microframecorp.com E-mail: support@microframecorp.com Manual No.

More information

Serial Port Plug - F2M01SXA Brief Datasheet. Features. Applications. General Description. Provides transparent RS-232 serial cable replacement.

Serial Port Plug - F2M01SXA Brief Datasheet. Features. Applications. General Description. Provides transparent RS-232 serial cable replacement. Serial Port Plug - F2M01SXA Features Provides transparent RS-232 serial cable replacement. No need for external drivers. Power is supplied via the D-SUB or mini-usb connector. Supports the Bluetooth Serial

More information

Owner s Manual. Industrial-Grade USB to RS-422/485 Serial Adapter. Models: U IND (1-Port), U IND (2-Port), U IND (4-Port)

Owner s Manual. Industrial-Grade USB to RS-422/485 Serial Adapter. Models: U IND (1-Port), U IND (2-Port), U IND (4-Port) Owner s Manual Industrial-Grade USB to RS-422/485 Serial Adapter Models: U208-001-IND (1-Port), U208-002-IND (2-Port), U208-004-IND (4-Port) Este manual esta disponible en español en la página de Tripp

More information

CANADIAN D.O.C. WARNING

CANADIAN D.O.C. WARNING Each product and program carries a respective written warranty, the only warranty on which the customer can rely. Avery Dennison Corp. reserves the right to make changes in the product, the programs, and

More information

4-port USB to RS232 Adapter FTDI Cable. Product Manual. Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI.

4-port USB to RS232 Adapter FTDI Cable. Product Manual. Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI. 4-port USB to RS232 Adapter FTDI Cable Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI 2 CG-4X232FTDI Product Manual Revision History Revision Date Author Comments 1.0

More information

USER MANUAL. VS-21HDCP-IR 2x1 DVI Switcher MODEL: P/N: Rev 5

USER MANUAL. VS-21HDCP-IR 2x1 DVI Switcher MODEL: P/N: Rev 5 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: VS-21HDCP-IR 2x1 DVI Switcher P/N: 2900-000556 Rev 5 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction User's Guide Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model 382280 382280 Introduction Congratulations on your purchase of the Extech 382280 Programmable DC Power Supply. This 200 watt

More information

User s Manual BTS1009C. Bluetooth to Serial Adapter. SUNIX Co., Ltd.

User s Manual BTS1009C. Bluetooth to Serial Adapter. SUNIX Co., Ltd. BTS1009C Bluetooth to Serial Adapter User s Manual Second Edition, April 2007 SUNIX Co., Ltd. Tel : +886-2-8913-1987 Fax: +886-2-8913-1986 Http://www.sunix.com.tw info@sunix.com.tw BTS1009C Bluetooth to

More information

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS FN:273MAN1.DOC AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS DESCRIPTION AEXX-273 Series Wireless Controlled Pace Clocks are available in with 1", 2.3", 4", 8", or 12" high digits, visible from 5 feet

More information

SMARTPLUG. Quick Start Guide. Model: isp6x. Intelligent Home Solutions. Control your SmartPlug from anywhere with your smartphone WHAT YOU LL NEED

SMARTPLUG. Quick Start Guide. Model: isp6x. Intelligent Home Solutions. Control your SmartPlug from anywhere with your smartphone WHAT YOU LL NEED Model: isp6x Intelligent Home Solutions Quick Start Guide SMARTPLUG Control your SmartPlug from anywhere with your smartphone WHAT YOU LL NEED WiFi network transmitting at 2.4GHz 1 Apple device running

More information

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom

PD1100 STAND-ALONE PROGRAMMING & USER S GUIDE. use the freedom PD1100 STAND-ALONE ALPHANUMERIC POLE DISPLAY PROGRAMMING & USER S GUIDE use the freedom Forward The information contained in this user s guide is subject to change without notice. This Programming and

More information

ELECTRICINEMA Connect IP Projection Screen

ELECTRICINEMA Connect IP Projection Screen ELECTRICINEMA Connect IP Projection Screen Thank you for purchasing a Screen Technics Projection Screen, please ensure that you read the following instructions fully before to install this product. Wall

More information

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM. 8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments

More information

Instructions. Modbus RTU Card (WSIQ-COM-MB)

Instructions. Modbus RTU Card (WSIQ-COM-MB) Instructions (WSIQ-COM-MB) Contents 1 Warnings... 2 2 Important User Information... 2 3 Installation... 2 4 Operation... 3 5... 4 6 Specifications... 15 Product Compatibility The is suitable for use with

More information

DRAFT AUTOMATE RS 485 SERIAL COMMAND GUIDE

DRAFT AUTOMATE RS 485 SERIAL COMMAND GUIDE AUTOMATE RS 485 SERIAL COMMAND GUIDE AUTOMATE ARC Pulse hub supports third party system integration through RS 485 communication. These instructions outline the fundamentals of the serial protocol, enabling

More information

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization Hall Research Technologies, Inc. Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization UMA1127 Rev B Copyright 2007. Hall Research Technologies, Inc. All rights 1163 Warner

More information

PrintPAD MC65. User Guide

PrintPAD MC65. User Guide 110288-000 PrintPAD MC65 User Guide TABLE OF CONTENTS PrintPAD MC65 Printer Views...1 Open View...1 Closed View...1 Using Batteries: General Guidelines...1 Installing and/or Replacing Batteries...2 Charging

More information

HDMI to 3GSDI Converter

HDMI to 3GSDI Converter HDMI to 3GSDI Converter EXT-HD-3G-C User Manual Release A2 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do

More information

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8 DVI KVM Extra Long Range Extender Over One CAT5 EXT-DVIKVM-ELR User Manual Release A8 Important Safety Instructions 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all

More information

Mondo TC. Quick Reference & Setup Guide

Mondo TC. Quick Reference & Setup Guide Mondo TC Quick Reference & Setup Guide 2791 Circleport Drive, Erlanger, KY 41018, USA. Americas: +1 859-282-7303 EMEA: +44 (0) 1843 873322 Email: tech.usa@tvone.com www.tvone.com CSG-MONDO-TC Version 1.0

More information

OWNER'S GUIDE BT 390

OWNER'S GUIDE BT 390 OWNER'S GUIDE BT 390 WIRELESS HEADPHONES Thank you for purchasing PHIATON BT 390. - Please follow the directions, and read the guidelines carefully before use. Please keep the owner s guide for future

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information

Mi.Net Mobile. Transceiver. Mueller Systems. operating Instructions manual

Mi.Net Mobile. Transceiver. Mueller Systems. operating Instructions manual operating Instructions manual Mi.Net Mobile table of contents PAGE General Information / Components 2 Installation 3 Configurations 4-5 LED Indicators 5 About Mueller Systems 6 Notes 7 Transceiver! WARNING:

More information

Installation and User Guide

Installation and User Guide Installation and User Guide Trademarks and Notices Notice Comtrol Corporation. SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF THIS PRODUCT FOR A PARTICULAR PURPOSE. Comtrol

More information

Megabit Modem MM300S INSTALLATION GUIDE

Megabit Modem MM300S INSTALLATION GUIDE Megabit Modem MM300S INSTALLATION GUIDE THE MEGABIT MODEM 300S The ADC Megabit Modem 300S (MM300S) provides a high-speed data connection over a single-pair copper line to another modem. The modem uses

More information

900 MHz Spread Spectrum Radio TOP FRONT. Click 400

900 MHz Spread Spectrum Radio TOP FRONT. Click 400 900 MHz Spread Spectrum Radio Click 400 The Click 400 is a 900 MHz spread spectrum radio with two RS-485 ports and one RS-232 port which are active at all times. The Click 400 auto-detects the serial settings

More information

245 Winch 50. User Manual

245 Winch 50. User Manual Jaegergaardsgade 160 DK-8000 Aarhus C DENMARK WWW.WAHLBERG.DK Front page 245 Winch 50 User Manual WWW.WAHLBERG.DK TELEPHONE +45 86 18 14 20 EMAIL: sales@wahlberg.dk Contents GENERAL:... 3 PRODUCT CONTENT:...

More information

LM Technologies Ltd. Quick Start Guide LM048 and LM058 Bluetooth Serial Adapters. 1 Package Contents. 2 Setup

LM Technologies Ltd. Quick Start Guide LM048 and LM058 Bluetooth Serial Adapters. 1 Package Contents. 2 Setup LM Technologies Ltd Quick Start Guide LM048 and LM058 Bluetooth Serial Adapters 1 Package Contents Single Retail Pack 1x Bluetooth Serial Adapter 1 x DB9 male to female connector 1 x USB mini USB cable

More information

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a

More information

M40Q 115VAC and 230VAC Series Motor P5 and M50Q 115VAC and 230VAC Series Motor P5 RQ Command Summary

M40Q 115VAC and 230VAC Series Motor P5 and M50Q 115VAC and 230VAC Series Motor P5 RQ Command Summary RQ enabled motors from Electronic Solutions, Inc. provide two-way communications over a 6-conductor (phone) cable that connects each of the motors together into an RQ Bus. Typically an RQ Bridge component

More information

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs LBC-PSW52 Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

Installation Operation

Installation Operation Installation Operation Luminette PowerGlide 2.0 with Platinum Technology Hard-Wired Motorization CONTENTS Getting Started: Install And Test The Headrail... 1 Understand The Connection Interface... 1 Lay

More information

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

EZ Switch EZ Connect N SMCFS1601/SMCFS2401 EZ Switch EZ Connect N Draft 16/24-Port 11n Wireless Fast Ethernet USB2.0 Adapter Switch SMCFS1601/SMCFS2401 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered

More information

Model: KB1700. Programmable Keypad. 17 Programmable Keys USER MANUAL

Model: KB1700. Programmable Keypad. 17 Programmable Keys USER MANUAL Model: KB1700 Programmable Keypad 17 Programmable Keys USER MANUAL NOTICE The manufacturer of the POS programmable keypad makes no representations or warranties, either expressed or implied, by or with

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

Copyright 2013 Esselte Leitz GmbH & Co. KG. All rights reserved.

Copyright 2013 Esselte Leitz GmbH & Co. KG. All rights reserved. Copyright 2013 Esselte Leitz GmbH & Co. KG. All rights reserved. Mac, ipad, AirPrint, and OS X are trademarks of Apple Inc., registered in the U.S. and other countries. Google and Google Cloud Print are

More information

60 GHz Wireless Dock Basic Model

60 GHz Wireless Dock Basic Model 60 GHz Wireless Dock Basic Model Model 107007 User Manual Email: support@cablematters.com Table of Contents 1. INTRODUCTION... 1 1.1 Introduction 1.2 Copyright and Trademarks 1.3 FCC Compliance Statement

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RB-6 6 Channel Power Controller. P/N: Rev 1

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RB-6 6 Channel Power Controller. P/N: Rev 1 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: RB-6 6 Channel Power Controller P/N: 2900-300024 Rev 1 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information

PUSH-TO-TALK USER GUIDE

PUSH-TO-TALK USER GUIDE Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits

More information

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM LS8000 Kitchen Display Station Controller with Android TM USER MANUAL NOTICE The manufacturer of the kitchen video controller makes no representations or warranties, either expressed or implied, by or

More information

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200

More information

Combo PS/2 and USB - Cat 5 KVM Extender, 200 m DS (Local Unit) DS (Remote Unit) User s Manual

Combo PS/2 and USB - Cat 5 KVM Extender, 200 m DS (Local Unit) DS (Remote Unit) User s Manual Combo PS/2 and USB - Cat 5 KVM Extender, 200 m DS-51110 (Local Unit) DS-51110 (Remote Unit) User s Manual Index 1 INTRODUCTION... 2 1.1 FEATURES... 3 1.2 PACKAGE CONTENTS... 3 1.3 SPECIFICATIONS... 4 2

More information

User Guide Microsoft Portable Power (DC-21)

User Guide Microsoft Portable Power (DC-21) User Guide Microsoft Portable Power (DC-21) Issue 1.0 EN-US User Guide Microsoft Portable Power (DC-21) Contents For your safety 3 About your portable charger 4 Keys and parts 5 Charge your portable charger

More information

USB/VGA Cat 5 UTP Long Range Console Extender

USB/VGA Cat 5 UTP Long Range Console Extender USB/VGA Cat 5 UTP Long Range Console Extender SV565UTPUL *actual product may vary from photos FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital

More information

LVS 7510 Integrated System Installation and Quick Start Guide for Zebra Printers

LVS 7510 Integrated System Installation and Quick Start Guide for Zebra Printers LVS 7510 Integrated System Installation and Quick Start Guide for Zebra Printers P/N 84-9320003-02 Rev D Copyright 2018 Omron Microscan Systems, Inc. Tel: +1.425.226.5700 / 800.762.1149 Fax: +1.425.226.8250

More information

PR3400 Series 1.4Mp USB Cameras Hardware Guide

PR3400 Series 1.4Mp USB Cameras Hardware Guide PR3400 Series 1.4Mp USB Cameras Hardware Guide Manufactured by: SPOT Imaging Solutions, a division of Diagnostic Instruments, Inc. 6540 Burroughs Ave. Sterling Heights, MI 48314-2133 USA Toll-Free: 866-604-SPOT

More information

ENGINEERING G. M. B. H. ENGINEERING MAKES THE DIFFERENCE

ENGINEERING G. M. B. H. ENGINEERING MAKES THE DIFFERENCE ENGINEERING G. M. B. H. ENGINEERING MAKES THE DIFFERENCE CLERMONT-FERRAND-ALLEE 36 D-93049 REGENSBURG TEL 0941/29638 0, FAX 90 EMAIL info@bauer-eng.de INTERNET http://www.bauer-eng.de POF MPX (Plastic

More information

SERIES 208 INSTALLATION & OPERATING MANUAL

SERIES 208 INSTALLATION & OPERATING MANUAL SERIES 208 INSTALLATION & OPERATING MANUAL Microframe Corporation 604 South 12th Street Broken Arrow, OK 74012 Local: 918-258-4839 Toll Free: 800-635-3811 Website: www.microframecorp.com E-mail: support@microframecorp.com

More information

3 Input Multiplexer Operation Manual

3 Input Multiplexer Operation Manual ProMUX-3 3 Input Multiplexer Operation Manual WARRANTY Accurate Technology, Inc. warrants the ProMUX-3 against defective parts and workmanship for 1 year commencing from the date of original purchase.

More information

Lantronix UDS-10 (CoBox) w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes

Lantronix UDS-10 (CoBox) w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes Lantronix UDS-10 () w/sielox Firmware B03.54 or greater Set-up, Installation, and FAQ Notes June 2005 (Updated March 2006) Copyright 2006 by Sielox, LLC. Published by: Sielox 170 East Ninth Avenue Runnemede,

More information

MONOPRICE. Blackbird 4K 5x1 HDMI Presentation Switch. User's Manual P/N 21906

MONOPRICE. Blackbird 4K 5x1 HDMI Presentation Switch. User's Manual P/N 21906 MONOPRICE Blackbird 4K 5x1 HDMI Presentation Switch P/N 21906 User's Manual CONTENTS SAFETY WARNINGS AND GUIDELINES... 4 INTRODUCTION... 4 FEATURES... 5 CUSTOMER SERVICE... 5 PACKAGE CONTENTS... 6 PRODUCT

More information

General Notice Introduction Functional Description Product Troubleshooting Driver Setup...

General Notice Introduction Functional Description Product Troubleshooting Driver Setup... Table of Contents General Notice... 1 Introduction... 2 Functional Description... 4 Product Troubleshooting... 7 Driver Setup... 8 Firmware Update... 10 Warranty and Service... 12 General Notice The Bluetooth

More information

DS232. RS232 to DMX Converter V4. ELM Video Technology s RS232 to DMX Converter / Controller

DS232. RS232 to DMX Converter V4. ELM Video Technology s RS232 to DMX Converter / Controller DS232 V4 ELM Video Technology s RS232 to DMX Converter / Controller RS232 RS232 Source DMX Device: Dimmers, Moving Heads, LED Pars, Splitters, Relays, etc. OVERVIEW The DS232 is an RS232 to DMX controller.

More information

7A HDQ MOTOR WIRING AND PROGRAMMING

7A HDQ MOTOR WIRING AND PROGRAMMING 7A HDQ MOTOR WIRING AND PROGRAMMING HDQ Motor Wiring and Programming Guide This Document is intended to assist electricians, integrators and advanced automation system designers in building and communicating

More information

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack) Bluetooth v.0, v. RS Serial Adapter Revised 8/NOV/0.mm mm mm Features World s smallest Bluetooth Serial Adapter (RS) Bluetooth v.0, v. wireless technology 8 dbm Tx Power and -8 dbm Rx Sensitivity Serial

More information

Industrial RFID Reader

Industrial RFID Reader Industrial RFID Reader User s Manual for the following models: FCC ID: IOL-125-AV1015 (6 Coil System) FCC ID: IOL-125-AV1016 (12 Coil System) FCC ID: IOL-125-AV1017 (24 Coil System) The device complies

More information

Perle SMI Media Converter Installation Guide

Perle SMI Media Converter Installation Guide Perle SMI Media Converter Installation Guide P/N 5500316-14 Overview This guide contains instructions necessary for the installation and operation of the Perle SMI Media Converter. This media converter

More information

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3

USER MANUAL. VA-1USB-T USB Transmitter. VA-1USB-R USB Receiver MODELS: P/N: Rev 3 KRAMER ELECTRONICS LTD. USER MANUAL MODELS: VA-1USB-T USB Transmitter VA-1USB-R USB Receiver P/N: 2900-300209 Rev 3 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2

More information

Quick Start Guide. GV-Video Server

Quick Start Guide. GV-Video Server Quick Start Guide GV-Video Server Thank you for purchasing GV-Video Server. This guide is designed to assist the new user in getting immediate results from the GV-Video Server. For advanced information

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

Serial No. OWNER S MANUAL. Installation & Operation

Serial No. OWNER S MANUAL. Installation & Operation Serial No. OWNER S MANUAL Installation & Operation Table of Contents Safety & Warranty Warnings 01 Parts List 02 GhostBed Electronics Quick Reference Guide... 03 Installation Guide 04 GhostBed Remote Control

More information

AUD-340 Installation Guide

AUD-340 Installation Guide F0123456789ABC DE AUD-340 Installation Guide INPUTS CONTROL OUTPUT 24V DC 48V LINE 2 AUDIO IR RS232 COM 70V 100V 1 3 DIGITAL L R AUDIO 2.5A MAX TX RX 1 2 3 INPUT SELECT LINE BASS TREBLE MUTE 1 Safety Precautions

More information

MANUAL v1. KEY for DISCOVERIES MOTORISED LASER POWER ATTENUATOR. LPA series

MANUAL v1. KEY for DISCOVERIES MOTORISED LASER POWER ATTENUATOR. LPA series MANUAL v1 KEY for DISCOVERIES MOTORISED LASER POWER ATTENUATOR LPA series Table of contents Table of contents... 2 1. Safety requirements... 4 2. Operation principle... 5 2.1. Features and advantages...

More information

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM24x Quick-Connect Industrial Modem. User s Manual ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of

More information

AUD-220 Installation Guide

AUD-220 Installation Guide AUD-220 Installation Guide STEREO MONO BRIDGE IR RS232 TX RX MIC 48V LINE L R MIC 1 2 INPUTS 24V DC 1 x 40W @ 8Ω 2 x 20W @ 4Ω LOOP OUTPUTS The Intelix AUD-220 is a 2x20 watt Class D amplifier with 8Ω speaker

More information

4K Ultra HD ELR-POL Extender w/ RS-232, Ethernet and 2-way IR

4K Ultra HD ELR-POL Extender w/ RS-232, Ethernet and 2-way IR 4K Ultra HD ELR-POL Extender w/ RS-232, Ethernet and 2-way IR EXT-UHD-CAT5-ELRPOL User Manual Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings.

More information

SPOTTER the multipurpose sensor

SPOTTER the multipurpose sensor SPOTTER the multipurpose sensor OVERVIEW Part of the Quirky + GE collection of smart products, Spotter is a multipurpose sensor that keeps you updated on what s going on at home from anywhere. Monitor

More information

Matrix for HDMI 1.3 EXT-HDMI User Manual. Release A7

Matrix for HDMI 1.3 EXT-HDMI User Manual. Release A7 Matrix for HDMI 1.3 EXT-HDMI1.3-444 User Manual Release A7 4x4 Matrix for HDMI 1.3 Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow

More information