1 These instructions are customized for the CNet Modem V.90 k bps modem (P/N D) contained in the i Modem Kit P/N 9, i Modem Kit P/N 90B, and the i and 0i Modem Kit P/N 9. The modem connected to the system DCI or LAPB (called the site modem) should be modem P/N D. The modem connected to your PC (called the office modem) should be P/N D or an equivalent modem. This modem supports V. Error Correction. If your office modem accepts command AT&Q, it is V./V. compatible. You must use your system s Remote Maintenance program - system programs are not interchangeable. (Example: You cannot use the i Remote Maintenance program with i system.) i-series Remote Modem Installation Instructions Part No. 900MDM November 00 Printed in U.S.A. (0)

2 This manual has been developed by NEC America. It is intended for the use of its customers and service personnel, and should be read in its entirety before attempting to install or program the system. Any comments or suggestions for improving this manual would be appreciated. Forward your remarks to: NEC America Inc., Corporate Networks Groups Forest Parkway Shelton, CT 0 cng.nec.com Nothing contained in this guide shall be deemed to be, and this guide does not constitute, a warranty of, or representation with respect to, any of the equipment covered. This guide is subject to change without notice and NEC America has no obligation to provide any updates or corrections to this guide. Further, NEC America also reserves the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No representation is made that this guide is complete or accurate in all respects and NEC America shall not be liable for any errors or omissions. In no event shall NEC America be liable for any incidental or consequential damages in connection with the use of this guide. 00 by NEC America. All Rights Reserved. Printed in U.S.A. Year 000 Compliance The i and i and their associated PC programs are unaffected by the date change to year 000. The system processes the Leap Year correctly and does not require any additional upgrades or reprogramming. With i or i EXCPRU or Base software.0 or higher, the system uses a four-digit date code entry (e.g., 000). Previous versions use a two-digit date code entry (e.g., 00=000). The i and 0i and their associated PC programs are unaffected by the date change to year 000. The system processes the Leap Year correctly and does not require any additional upgrades or reprogramming. With software.0. or higher or with 0i software, the systems use a four-digit date code entry (e.g., 000). Previous versions use a two-digit date code entry (e.g., 00=000).

3 i/i Remote Modem Installation Instructions To set up the remote modem for the i and 0i, go to page. Use these instructions to install a i or i Remote Modem in six easy steps:. Initialize the Site Modem. Connecting to the System. Test Your Site Modem Setup. Set Up Your Office Modem. Connecting to the Site Modem. Upload a Test Block Your remote modem connects to a LAPB Module in the system cabinet. The i uses the LAPB P/N 90 and the i uses P/N 900. The LAPB Module is a daughter board that plugs in the CPRU PCB. Using one of the cable sets listed below, these modules allow you to connect to a local PC or a remote modem allowing you to program the system. i PC Programming Cable Sets For local PC connections, use DB9-to--Pin Cable Set (P/N 90-DB9). This cable set consists of the following two components: -Pin Circular Mini-DIN to Mod- Cable (P/N 90A) This 0 long cable has an -pin right angle connector on one end (for connecting to the LAPB) and a standard -pin modular plug on the other end. DB9-to-Mod- Adaptor (P/N 90) One end of this adaptor accepts an -pin modular plug. The other end is a standard DB9 female connector that you can plug into a 9-pin RS (DTE) port on your PC or laptop. For modem connections, use DB-to--Pin Cable Set (P/N 90-DB). This cable set consists of the following two components: -Pin Circular Mini-DIN to Mod- Cable (P/N 90A) This 0 long cable has an -pin right angle connector on one end (for connecting to the LAPB) and a standard -pin modular plug on the other end. DB-to-Mod- Adaptor (P/N 9) One end of this adaptor accepts an -pin modular plug. The other end is a standard DB male connector. This connector is plugged into the DB female connector on the cable that ships with the CNet modem. The 9-pin male connector on the CNet modem cable is then plugged into the DCE port of the modem.

4 i/i Remote Modem Installation Instructions i PC Programming Cable Sets For local PC connections, use DB9-to--Pin Cable Set (P/N 9009-DB9). This cable set consists of the following two components: -Pin Circular Mini-DIN to Mod- Cable (P/N 09) This 0 long cable has an -pin connector on one end (for connecting to the LAPB) and a standard -pin modular plug on the other end. DB9-to-Mod- Adaptor (P/N 90) One end of this adaptor accepts an -pin modular plug. The other end is a standard DB9 female connector that you can plug into a 9-pin RS (DTE) port on your PC or laptop. For modem connections, use DB-to--Pin Cable Set (P/N 9009-DB). This cable set consists of the following two components: -Pin Circular Mini-DIN to Mod- Cable (P/N 09) This 0 long cable has an -pin connector on one end (for connecting to the LAPB) and a standard -pin modular plug on the other end. DB-to-Mod- Adaptor (P/N 9) One end of this adaptor accepts an -pin modular plug. The other end is a standard DB male connector. This connector is plugged into the DB female connector on the cable that ships with the CNet modem. The 9-pin male connector on the CNet modem cable is then plugged into the DCE port of the modem. Default Settings The default settings for the LAPB card are 900 bps, Start bit=, Stop bit=, Parity=No, Character= bit. These settings cannot be changed. Pin-Out Details If you wish to use your own cables, follow the pin-out information below for the cables and connectors P/N 09 Brown wire (Pin ) DSR RTS RXD SG TXD CTS DTR DCD i -Pin DIN to Mod- Connector -Pin DIN Mod- DSR RTS RXD SG TXD CTS DTR DCD i -Pin DIN to Mod- Connector

5 i/i Remote Modem Installation Instructions x JACK WIRING PIN COLOR BLUE ORANGE BLACK RED GREEN YELLOW BROWN SLATE DB WIRING PIN COLOR 0 YELLOW GREEN SLATE BROWN BLUE RED ORANGE BLACK x JACK WIRING PIN COLOR BLUE ORANGE BLACK RED GREEN YELLOW BROWN SLATE PIN 9 DB9 WIRING COLOR JUMPER TO PIN YELLOW GREEN BLUE AND ORANGE RED BLACK JUMPERED TO PIN BROWN SLATE Mod- to -Pin Connector for Modem Connection Mod- to 9-Pin Connector for PC/Laptop Connection To connect to a local PC, skip to the. Connecting to the System.. Initialize the Site Modem You must send an initialization (INIT) string to your modem before connecting it to the system. You ll need a laptop (or other PC) on site to do this. There are three parts to this procedure: Connecting the modem to your laptop. Entering the site modem INIT string into the Remote Maintenance program. Sending and storing the INIT string in the site modem. To connect the modem to your laptop (refer to the illustration on page ):. Connect the modem power supply to the POWER jack on the back of the modem.. Plug the male end of the 9-pin connector of the cable that is included with the CNet modem into the RS- connector on the back of the modem.. Plug the 9-pin female end of the same cable into the serial port on the back of your laptop (or PC). Check the manuals that came with your computer if you re not sure how to set up and connect the modem.. Plug the modem power supply into a 0 V AC receptacle and turn the unit on.

6 i/i Remote Modem Installation Instructions DOS PC Program Only: Enter the site modem INIT string into the Remote Maintenance program:. Make sure your modem is properly connected to your computer and functioning correctly. Your modem can only connect to COM or COM.. Start the Remote Maintenance program and enter your programming password (when requested).. From the Main Menu, select Option and press Enter.. Select RS Port and press Enter.. Set the RS options for: 900 (speed), (length), none (Parity), (Stop Bit), Off (echo) and COM Port ( or ), then press Enter twice and press then ESC. You will advance to the Modem Initialize Command window. To send and store the INIT string in the site modem:. From the Main Menu, select Communication and press Enter.. Select Modem Control and press Enter.. Type AT&F to default the modem. OK will display on the screen.. Enter the following initialization string (spaces shown for clarity): AT Q &C &D0 &S S0= E0 &W0 &W and press Enter. For earlier CNet modems (P/N, A, B, C) use: AT Q Y &C &D0 &S S0= E0 &W0 &W and press Enter.. To view all the modem settings and check the INIT string, type AT&V and press Enter. The INIT string you sent in step is contained in the data that displays. Review the displayed Active Profile, Stored Profile 0 or Stored Profile data to be sure your entries were correct. (Not all types of modems are compatible with all these commands and will disregard the entries for some items.) Windows PC Program Only: Enter the site modem INIT string with Windows HyperTerminal program:. Make sure your modem is properly connected to your computer and functioning correctly. Your modem can connect to COM,COM, COM or COM.. Start the HyperTerminal program. (Click START - PROGRAMS - ACCESSORIES - HYPERTERMINAL. Double-click on the HYPERTRM.EXE file.). Create a name for the new connection, such as MODEM SETUP and click OK.. Select the COM Port ( - ) to be used and click OK.. Set the RS options for: 900 (Bits per Second), (Data Bits), none (Parity), (Stop Bits), None (Flow Control) then click OK.

7 i/i Remote Modem Installation Instructions To send and store the INIT string in the site modem:. Type AT&F and press Enter to default the modem. OK will display on the screen.. Enter the following initialization string (spaces shown for clarity): AT Q &C &D0 &S S0= E0 &W0 &W and press Enter. For earlier CNet modems (P/N, A, B, C) use: AT Q Y &C &D0 &S S0= E0 &W0 &W and press Enter.. To view all the modem settings and check the INIT string, type AT&V and press Enter. The INIT string you sent in step is contained in the data that displays. Review the displayed Active Profile, Stored Profile 0 or Stored Profile data to be sure your entries were correct. (Not all types of modems are compatible with all these commands and will disregard the entries for some items.) Close the HyperTerminal Program. You do not need to save the modem file created. Now that the site modem is properly initialized, you must disconnect it from your laptop and connect it to the system. Disconnecting the modem from the laptop:. Turn the site modem off. The INIT string you sent previously will automatically be loaded from the modem s memory when you turn it back on.. Unplug the cable from your laptop and the modem.. Connecting to the System. With the system power turned off, pull the CPRU PCB out of the system. With the i system, make sure the mode switch on the CPRU is set to the HOT position to retain the customer information. The i will automatically retain the customer information unless the COLD switch is held down during power up.. Plug the LAPB Remote Programming Module into the header on the CPRU PCB.. Reinsert the CPRU into the system cabinet and turn the power back on. Modem Connection. Using the correct cable configuration for a modem setup (i=90-db, i=9009-db), connect the DIN connector on the cable (i=p/n 90A, i=09) to the LAPB card.. Connect the -pin adaptor to the opposite end of the cable.. Plug the connector into the -pin female connector on the modem s cable set (shipped with modem). Plug the 9-pin male connector at the opposite end of the modem s cable set into the modem.. Plug one end of a modular line cord into the LINE jack on the back of the modem.. Plug the other end of the modular line cord into a modular jack connected to an ASTU port or other dial tone source (such as an outside line).. Turn your modem back on.

8 i/i Remote Modem Installation Instructions Local Connection. Using the correct cable configuration (i=90-db9, i=9009-db9), connect the DIN connector on the cable (P/N 09) to the -pin serial (LAPB) connector on the CPRU.. Connect the 9-pin adaptor to the opposite end of the cable.. Plug the connector into the COM port on your PC. Skip to. Connecting to the Site. i Cabinet Shown CPRU PCB ASTU PCB LAPB PCB MI-0 Station Block -Pair Cable Pin DIN to Mod Cable The i uses P/N 90x. The i uses P/N 09. Station Cable Mod to 9 Pin Connector (P/N 90) Mod to Pin Connector (P/N 9) Pin Connector (Cable included with Modem) PC 9-Pin Connector Not Used for Modem Connection 9-Pin Connector Modular Jack Modem

9 i/i Remote Modem Installation Instructions. Test Your Site Modem s Setup Never leave the site without testing your PC and site modem setup. This will require a second modem (supporting V. error correction and a minimum of 900 baud) and another available ASTU port, outside line or dial tone source. Testing ensures the modems can communicate properly and the system will properly release a connection. To test the modem setup:. Plug one end of a modular line cord into the LINE jack on the back of the second modem.. Plug the other end of the modular line cord into a modular jack connected to a different ASTU port or dial tone source.. Connect the modem s power supply and turn the unit on.. From the PC connected to the second modem, follow the procedures in Part, Set Up Your Office Modem, Part. Connecting to the Site and Part. Upload a Test Block to test your modem.. Set Up Your Office Modem You must set up and check your office modem before calling the site modem. Also use this procedure when testing the site modem from another modem on site. DOS PC Program Only: To set up your office modem:. Make sure your modem is correctly connected to your office computer. Your modem can only connect to COM or COM.. Start the Remote Maintenance program and enter your programming password (when requested).. From the Main Menu, select Options and press Enter.. Select RS Port and press Enter.. Set the RS options for: 900 (speed), (length), none (Parity), (Stop Bit), Off (echo), COM Port ( or ) and then press Enter. You will advance to the Modem Initialize Command window. These settings must match those you made for Program 0 in Step - Program the DCI.. Enter the initialization string (spaces shown for clarity): E Q0 M V0 &C &D and press Enter.. Press F to save your changes, then press Esc to return to the Main Menu.

10 i/i Remote Modem Installation Instructions To test your office modem setup: Never call the site modem without first using the following steps to test your office modem.. From the Main Menu, select Communication and press Enter.. Select Modem Control and press Enter.. Type AT&F and press Enter. Your computer should echo back OK. If you don t get the proper response (OK), check your modem connections and settings and repeat step. Windows PC Program Only: To set up your office modem using Windows HyperTerminal program:. Make sure your modem is properly connected to your computer and functioning correctly. Your modem can connect to COM, COM, COM or COM.. Start the HyperTerminal program. (Click START - PROGRAMS - ACCESSORIES - HYPERTERMINAL. Double-click on the HYPERTRM.EXE file.). Create a name for the new connection, such as MODEM SETUP and click OK.. Select the COM Port ( - ) to be used and click OK.. Set the RS options for: 900 (Bits per Second), (Data Bits), none (Parity), (Stop Bits), None (Flow Control) then click OK. These settings must match those you made for Program 0 in Step - Program the DCI.. Enter the initialization string (spaces shown for clarity): AT E0 Q0 M V &C &D and press Enter.. Connecting to the Site Now that your connection is correctly set up and tested, you can call the site modem and program remotely from your office or program the system locally through a PC. Also use this procedure when testing the site modem from another modem on site. DOS PC Program Only: To connect to the site:. Make sure your modem is correctly connected to your office computer, an outside telephone line (or other dial tone source) and is functioning correctly. Your modem can only connect to COM or COM.. Start the Remote Maintenance program and enter your programming password (when requested).

11 i/i Remote Modem Installation Instructions. From the Main Menu, load the data file for the site you are calling: Select File and Read. Choose the directory that contains your customer data files and press Enter. Highlight the customer data file you want to load and press Enter. If you are using this procedure to check the site modem while on site, make sure the Modem phone entry is the extension number of the ASTU circuit (or dial tone source) connected to the site modem.. Press Esc to return to the Main Menu, select Communication and press Enter.. Select Modem Control and press Enter. For Local PC Connections, skip to Step 9.. Type AT&F and press Enter. You should see OK. If you don t get the proper response (OK) or you can t type the entry, check your modem connections and settings and try again.. Press F: Auto Dial. This automatically sends out the initialization string you entered in Part and the Modem phone entry in the Customer Information Screen. If you don t have a Modem phone entry, press Enter, type ATDT, the site modem s telephone number and press Enter again.. After you connect to the site modem, you will see a numeric connect message (). This is the connect message returned by the site modem. 9. Type AT and press Enter. You should see OK. This response is from the site s LAPB. If you don t see OK, press F to break the connection and Esc when prompted to do so. Repeat from step. If you still don t see OK, there is a problem with the site modem s LAPB setup. 0. Type ATD #*#* and press Enter. If you see ERROR, type ATZ to reset the site s LAPB. You can then go on to step.. When the remote system asks for the password, enter the programming password and press Enter. You can now program the remote system. If you see an ID code/software version error message, type U to update.. Press Esc twice to return to the Main Menu. Windows PC Program Only: To connect to the site:. Make sure your modem is correctly connected to your office computer, an outside telephone line (or other dial tone source) and is functioning correctly. Your modem can connect to COM, COM, COM or COM. 9

12 i/i Remote Modem Installation Instructions. For Modem Connection: Select the Remote Operation in the Windows PC Program and enter your database password (when requested). Then enter the modem s telephone number and click Dial. OR For Local Connection: Select the Online (Local) Operation in the Windows PC Program and enter your database password (when requested).. Select either DCI or LAPB, depending on equipment being used.. Once connected (this could take a couple of minutes depending on the type of connection), enter the programming password when requested.. Upload a Test Block Now that you have connected to the system, you should upload a block of data to make sure that the communications are working correctly. DOS PC Program Only:. From the Main Menu, select Communication and press Enter.. Select ME->PC and press Enter.. Choose Select Programs and press Enter.. Select 0 Extension Options and press Enter.. Select 00 Station Class of Service and press Enter. This marks program 00 for uploading to your PC.. Press F0 to upload the data.. When you see the Receiving Completed message, press Esc then F to return to the Modem Screen.. Press F to break the connection, then Esc repeatedly until you return to the Main Menu. 9. Quit the Remote Maintenance program and disconnect your test modem. Windows PC Program Only:. In the Windows PC Program, click the Download icon ( ).. Depending on your software version, the program will either download all the system data or it will give you an option to select the programs to be downloaded. If your software allows you to select programs, select the Programs (090-90) tab and click the box next to 00 Station COS. Click OK. The data is downloaded to the system.. Click the Exit icon ( ).. Click No to discard the downloaded information. 0

13 i/0i Remote Modem Installation Instructions To set up the remote modem for the i or i, go to page. Important: The 0i Must Have CPRU Version LAPB. or higher and System Software.0.0 or higher for Remote Programming. Use these instructions to install a i or 0i Remote Modem in seven easy steps:. Program the DCI / Serial (LAPB) Port. Initialize the Site Modem. Connecting to the System. Test Your Site Modem s Setup. Set Up Your Office Modem. Connecting to the Site. Upload a Test Block On the 0i system with CPRU version LAPB. or higher and system software.0.0, your remote modem can connect to the -pin LAPB DIN connector on the CPRU (P/N 9). Using one of the cable sets listed below, you can connect to a local PC or a remote modem allowing you to program the system. 0i PC Programming Cable Sets For local PC connections, use DB9-to--Pin Cable Set (P/N 9009-DB9). This cable set consists of the following two components: -Pin Circular Mini-DIN to Mod- Cable (P/N 09) This 0 long cable has an -pin connector on one end (for connecting to the LAPB/Serial port) and a standard -pin modular plug on the other end. DB9-to-Mod- Adaptor (P/N 90) One end of this adaptor accepts an -pin modular plug. The other end is a standard DB9 female connector that you can plug into a 9-pin RS (DTE) port on your PC or laptop. For modem connections, use DB-to--Pin Cable Set (P/N 9009-DB). This cable set consists of the following two components: -Pin Circular Mini-DIN to Mod- Cable (P/N 09) This 0 long cable has an -pin connector on one end (for connecting to the LAPB/Serial port) and a standard -pin modular plug on the other end. DB-to-Mod- Adaptor (P/N 9) One end of this adaptor accepts an -pin modular plug. The other end is a standard

14 i/0i Remote Modem Installation Instructions DB male connector. This connector is plugged into the DB female connector on the cable that ships with the CNet modem. The 9-pin male connector on the CNet modem cable is then plugged into the DCE port of the modem. Default Settings The default settings for the serial port are 900 bps, Start bit=, Stop bit=, Parity=No, Character= bit. These settings cannot be changed. Pin-Out Details If you wish to use your own cables, follow the pin-out information below for the cables and connectors. P/N Brown wire (Pin ) -Pin DIN Mod- DSR RTS RXD SG TXD CTS DTR DCD -Pin DIN to Mod- Connector x JACK WIRING PIN COLOR BLUE ORANGE BLACK RED GREEN YELLOW BROWN SLATE DB WIRING PIN COLOR 0 YELLOW GREEN SLATE BROWN BLUE RED ORANGE BLACK x JACK WIRING PIN COLOR BLUE ORANGE BLACK RED GREEN YELLOW BROWN SLATE PIN 9 DB9 WIRING COLOR JUMPER TO PIN YELLOW GREEN BLUE AND ORANGE RED BLACK JUMPERED TO PIN BROWN SLATE Mod- to -Pin Connector for Modem Connection Mod- to 9-Pin Connector for PC/Laptop Connection

15 i/0i Remote Modem Installation Instructions. Program the DCI / Serial (LAPB) Port Your remote modem connects to a DCI Module, DCI Unit, or the serial port on a 0i s CPRU (P/N 9). Customize the following programs before installing the modem. Refer to your system s Software and Hardware Manuals for additional information, if required. Changes made to DCI number also apply to the serial (LAPB) port on the 0i CPRU. DCI / DCI / Serial (LAPB) Connections Program 0 DCI / DCI Connection Only Program 000 Program 00 Program 0 Program 0 Type No Enter (i.e., the DCI Sub Type). Item No Enter to access the S-Registers. Make the following S-Register settings: Type = (DCI connected to modem) 0i Only: Data Transmission Time = Baud Rate = (900 BPS) Stop_Bit = 0 ( stop bit) Char_Len = ( data bits) Parity = 0 (no parity) i Only: RS_Timing = 0 (RTS control enabled) ER_Timing = 0 (DTR control enabled) CD_Timing = (CD control disabled) Flow_Cont = (No Flow Control) 0i Only: RS_Timing = 0 (RTS control enabled) ER_Timing = 0 (DTR control enabled) CD_Timing = (CD control disabled) Flow_Cont = 0 (Hardware Flow Control) STA PORT No Enter the port number to which the DCI is connected. Type Enter for a DCI module or for a DCI Unit. Order For a DCI Module, enter - for software port numbers -. For a DCI Unit, enter - for software port numbers - (e.g., corresponds to software ports -). DCI No Enter the DCI s software port number. Assign an unused extension number to the DCI software port. DCI No Enter the DCI s software port number. DCI Type Enter (DCI connected to modem). DCI Sub Type Enter.!! This step initializes the DCI!! DCI No Enter the DCI software port number (- for a DCI Module or - for a DCI Unit)

16 i/0i Remote Modem Installation Instructions Pin-Out Details RS-C DCI-to-Modem Adaptor Connector (P/N 9A) RS--C Connector 0 RS--C Pin Out Information Description DCD RXD TXD DTR DSR RTS CTS GND Direction of Signal Flow ( output or input) DCE (-DCI, DCI-A or Modem) -Pin RS--C Connector DTE (PC or Printer) DCI-to-Modem Adaptor Pin Out Information 0 -Pin Connector to to to to to to to to 0 To connect to a local PC, skip to the. Connecting to the System.. Initialize the Site Modem You must send an initialization (INIT) string to your modem before connecting it to the system. You ll need a laptop (or other PC) on site to do this. There are three parts to this procedure: Connecting the modem to your laptop. Entering the site modem INIT string into the Remote Maintenance program. Sending and storing the INIT string in the site modem. To connect the modem to your laptop (refer to the illustrations on page and 9):. Connect the modem power supply to the POWER jack on the back of the modem.. Plug the male end of the 9-pin RS--C straight through cable that is included with the CNet modem into the RS- connector on the back of the modem.. Plug the 9-pin female end of the same cable into the serial port on the back of your laptop (or PC). Check the manuals that came with your computer if you re not sure how to set up and connect the modem.. Plug the modem power supply into a 0 V AC receptacle and turn the unit on.

17 i/0i Remote Modem Installation Instructions i Only: To enter the site modem INIT string into the i Remote Maintenance program:. Make sure your modem is properly connected to your computer and functioning correctly. Your modem can only connect to COM or COM.. Start the Remote Maintenance program and enter your programming password (when requested).. From the Main Menu, select Option and press Enter.. Select RS Port and press Enter.. Set the RS options for: 900 (speed), (length), none (Parity), (Stop Bit), Off (echo) and COM Port ( or ), then press Enter twice and press ESC. You will advance to the Modem Initialize Command window. To send and store the INIT string in the site modem:. From the Main Menu, select Communication and press Enter.. Select Modem Control and press Enter.. Type AT&F to default the modem. OK will display on the screen.. Enter the following initialization string (spaces only shown for clarity): AT Q &C &D0 &S S0= E0 &W0 &W and press Enter. For earlier CNet modems (P/N, A, B, C) use: AT Q Y &C &D0 &S S0= E0 &W0 &W and press Enter.. To view all the modem settings and check the INIT string, type AT&V and press Enter. The INIT string you sent in step is contained in the data that displays. Review the displayed Active Profile, Stored Profile 0 or Stored Profile data to be sure your entries were correct. (Not all types of modems are compatible with all these commands and will disregard the entries for some items.) 0i Only: To enter the site modem INIT string using Windows HyperTerminal program:. Make sure your modem is properly connected to your computer and functioning correctly. Your modem can connect to COM, COM, COM or COM.. Start the HyperTerminal program. (Click START - PROGRAMS - ACCESSORIES - HYPERTERMINAL. Double-click on the HYPERTRM.EXE file.). Create a name for the new connection, such as MODEM SETUP and click OK.

18 i/0i Remote Modem Installation Instructions. Select the COM Port ( - ) to be used and click OK.. Set the RS options for: 900 (Bits per Second), (Data Bits), none (Parity), (Stop Bits), None (Flow Control) then click OK. To send and store the INIT string in the site modem:. Type AT&F and press Enter to default the modem. OK will display on the screen.. Enter the following initialization string (spaces only shown for clarity): AT Q &C &D0 &S S0= E0 &W0 &W and press Enter. For earlier CNet modems (P/N, A, B, C) use: AT Q Y &C &D0 &S S0= E0 &W0 &W and press Enter.. To view all the modem settings and check the INIT string, type AT&V and press Enter. The INIT string you sent in step is contained in the data that displays. Review the displayed Active Profile, Stored Profile 0 or Stored Profile data to be sure your entries were correct. (Not all types of modems are compatible with all these commands and will disregard the entries for some items.) Close the HyperTerminal Program. You do not need to save the modem file created. Now that the site modem is properly initialized, you must disconnect it from your laptop and connect it to the system. Disconnecting the modem from the laptop:. Turn the site modem off. The INIT string you sent previously will automatically be loaded from the modem s memory when you turn it back on.. Unplug the cable from your laptop.. Connecting to the System For a DCI Connection: Modem Connection. Connect the -pin female connector of the cable set connected to the modem to the -pin adaptor P/N 9A.. Connect the female end of a customer-provided -pin straight through cable to other end of adaptor P/N 9A.. Connect the male end of the -pin cable to the DCI port.. Plug one end of a modular line cord into the LINE jack on the back of the modem.. Plug the other end of the modular line cord into a modular jack connected to an ASTU port or other dial tone source (such as an outside line).. Turn your modem back on.

19 i/0i Remote Modem Installation Instructions Local Connection. Connect the female end of a customer-provided -pin straight through cable to your laptop.. Connect the male end of the -pin cable to the DCI port. If you re connecting a local PC, skip to. Connecting to the Site. For LAPB DIN Connection to CPRU (0i with.0.0 or Higher Only): Modem Connection. Using the correct cable configuration (modem setup = P/N 9009-DB), connect the DIN connector on the cable (P/N 09) to the -pin serial (LAPB) connector on the CPRU.. Connect the -pin adaptor (P/N 9) to the opposite end of the cable.. Plug the connector into the -pin female connector on the modem s cable set (shipped with modem). Plug the 9-pin male connector at the opposite end of the modem s cable set into the modem.. Plug one end of a modular line cord into the LINE jack on the back of the modem.. Plug the other end of the modular line cord into a modular jack connected to an ASTU port or other dial tone source (such as an outside line).. Turn your modem back on. Local Connection. Using the correct cable configuration (local PC setup = P/N 9009-DB9), connect the DIN connector on the cable (P/N 09) to the -pin serial (LAPB) connector on the CPRU.. Connect the 9-pin adaptor (P/N 90) to the opposite end of the cable.. Plug the connector into the COM port on your PC. Skip to. Connecting to the Site.

20 i/0i Remote Modem Installation Instructions Modem MIC POWER SPK RS- LINE PHONE 0 V AC Outlet Mod. jack To ASTU Port 9-Pin Connector Not Used DCI Connection 9000-

21 V V 9V 9V TEST POINTS V V 9V 9V GND PWR ON WARNING CAUTION i/0i Remote Modem Installation Instructions 0i Cabinet MI-0 Station Block CPRU Pin DIN LAPB Connector OUTPUT AC OUT AC IN -Pair Cable AC OUT OFF ON Pin DIN to Mod Cable (P/N 09) Station Cable Mod to 9 Pin Connector (P/N 90) Mod to Pin Connector (P/N 9) Pin Connector (Cable included with Modem) PC 9-Pin Connector Not Used for Modem Connection 9-Pin Connector Modular Jack Modem CPRU Serial Port Connection (0i Only) 9

22 i/0i Remote Modem Installation Instructions. Test Your Site Modem s Setup Never leave the site without testing your PC and site modem setup. This will require a second modem (supporting V. error correction and a minimum 900 baud) and another available ASTU port, outside line or dial tone source. Testing ensures the modems can communicate properly and the DCI/Serial port will properly release a connection. To test the modem setup:. Plug one end of a modular line cord into the LINE jack on the back of the second modem.. Plug the other end of the modular line cord into a modular jack connected to a different ASTU port or dial tone source.. Connect the modem s power supply and turn the unit on.. From the PC connected to the second modem, follow the procedures in Part. Set Up Your Office Modem, Part. Connecting to the Site and Part. Upload a Test Block to test your modem.. Set Up Your Office Modem You must set up and check your office modem before calling the site modem. Also use this procedure when testing the site modem from another modem on site. i Only: To set up your office modem:. Make sure your modem is correctly connected to your office computer. Your modem can only connect to COM or COM.. Start the Remote Maintenance program and enter your programming password (when requested).. From the Main Menu, select Options and press Enter.. Select RS Port and press Enter.. Set the RS options for: 900 (speed), (length), none (Parity), (Stop Bit), Off (echo), COM Port ( or ) and then press Enter. You will advance to the Modem Initialize Command window. These settings must match those you made for Program 0 in Step - Program the DCI / Serial (LAPB Port).. Enter the initialization string (spaces only shown for clarity): E Q0 M V0 &C &D and press Enter.. Press F to save your changes, then press Esc to return to the Main Menu. 0

23 i/0i Remote Modem Installation Instructions To test your office modem setup: Never call the site modem without first using the following steps to test your office modem.. From the Main Menu, select Communication and press Enter.. Select Modem Control and press Enter.. Type AT&F and press Enter. Your computer should echo back OK. If you don t get the proper response (OK), check your modem connections and settings and repeat step. 0i Only: To set up your office modem:. Make sure your modem is properly connected to your computer and functioning correctly. Your modem can connect to COM, COM, COM or COM.. Select the Online (Remote) Operation in the 0i Windows PC Program and enter your database password (when requested).. Click the PORT SETTINGS button.. Select the COM Port ( - ) to be used and set the RS options for: 900 (Bits per Second), (Data Bits), none (Parity), (Stop Bits), None (Flow Control) then click OK. These settings must match those you made for Program 0 in Step - Program the DC / Serial (LAPB Port).. Click the INITIALIZE MODEM button. Without changing the initialize string, click OK. To test your office modem using Windows HyperTerminal program: Never call the site modem without first using the following steps to test your office modem.. Start the HyperTerminal program. (Click START - PROGRAMS - ACCESSORIES - HYPERTERMINAL. Double-click on the HYPERTRM.EXE file.). Create a name for the new connection, such as MODEM SETUP and click OK.. Select the COM Port ( - ) to be used and click OK.. Set the RS options for: 900 (Bits per Second), (Data Bits), none (Parity), (Stop Bits), None (Flow Control) then click OK.. Type AT&F and press Enter to default the modem. If you don t get the proper response (OK), check your modem connections and settings and repeat step. Close the HyperTerminal Program. You do not need to save the modem file created.

24 i/0i Remote Modem Installation Instructions. Connecting to the Site Now that your office modem is correctly set up and tested, you can call the site modem and program remotely from your office. Also use this procedure when testing the site modem from another modem on site. i Only: To call the site modem:. Make sure your modem is correctly connected to your office computer, an outside telephone line (or other dial tone source) and is functioning correctly. Your modem can only connect to COM or COM.. Start the Remote Maintenance program and enter your programming password (when requested).. From the Main Menu, load the data file for the site you are calling: Select File and Read. Choose the directory that contains your customer data files and press Enter. Highlight the customer data file you want to load and press Enter. If you are using this procedure to check the site modem while on site, make sure the Modem phone entry is the extension number of the ASTU circuit (or dial tone source) connected to the site modem.. Press Esc to return to the Main Menu, select Communication and press Enter.. Select Modem Control and press Enter. For Local PC Connections, skip to Step 9.. Type AT&F and press Enter. You should see OK. If you don t get the proper response (OK) or you can t type the entry, check your modem connections and settings and try again.. Press F: Auto Dial. This automatically sends out the initialization string you entered in Part and the Modem phone entry in the Customer Information Screen. If you don t have a Modem phone entry, press Enter, type ATDT, the site modem s telephone number and press Enter again.. After you connect to the site modem, you will see a numeric connect message (). This is the connect message returned by the site modem. 9. Type AT and press Enter. You should see OK. This response is from the site modem s DCI connection. If you don t see OK, press F to break the connection and Esc when prompted to do so. Repeat from step. If you still don t see OK, there is a problem with the site modem s DCI setup.

25 i/0i Remote Modem Installation Instructions 0. Type ATDT #*#* and press Enter. If you see ERROR, type ATZ to reset the site modem s DCI/serial port. You can then go on to step.. When the remote system asks for the password, enter the programming password and press Enter. You can now program the remote system. If you see an ID code/software version error message, type U to update.. Press Esc twice to return to the Main Menu. 0i Only: To call the site modem:. Select the Online (Remote) Operation in the 0i Windows PC Program and enter your database password (when requested).. Enter the modem s telephone number and click Dial.. Select either DCI or LAPB, depending on equipment being used. The LAPB requires 0i software.0.0 or higher.. Once the modem connects (this could take a couple of minutes), enter the programming password when requested.. Upload a Test Block Now that you have connected to the system through your laptop and the site modem, you should upload a block of data to make sure that the communications are working correctly. i Only:. From the Main Menu, select Communication and press Enter.. Select ME->PC and press Enter.. Choose Select Programs and press Enter.. Select 0 Extension Options and press Enter.. Select 00 Station Class of Service and press Enter. This marks program 00 for uploading to your PC.. Press F0 to upload the data.. When you see the Receiving Completed message, press Esc then F to return to the Modem Screen.. Press F to break the connection, then Esc repeatedly until you return to the Main Menu. 9. Quit the Remote Maintenance program and disconnect your test modem.

26 i/0i Remote Modem Installation Instructions 0i Only:. In the Windows PC Program, click the Download icon ( ). Select the Programs (090-90) tab and click the box next to 00 Station COS. Click OK. The data is downloaded to the system.. Click the Exit icon ( ).. Click No to discard the downloaded information.

27 NEC America, Inc., Corporate Networks Group Forest Parkway, Shelton, CT 0 Tel: Fax: 0-9- cng.nec.com Other Important Telephone Numbers Sales: Customer Service: Customer Service FAX: Technical Service: Discontinued Product Service: Technical Training: Emergency Technical Service (After Hours) (Excludes discontinued products)

28 NEC America, Inc., Corporate Networks Group Forest Parkway, Shelton, CT 0 TEL: FAX: cng.nec.com

TAPI (through 1.5 software) Installation Instructions. Technical Support Web Site: (registration is required)

TAPI (through 1.5 software) Installation Instructions. Technical Support Web Site:  (registration is required) TAPI (through 1.5 software) Installation Instructions Technical Support Web Site: http://208.141.100.36 (registration is required) This manual has been developed by NEC America. It is intended for the

More information

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.:

VISY-X. Technical Documentation. Cinterion MC 55 i. Edition: Version: 1 Article no.: Technical Documentation VISY-X Edition: 2016-10 Version: 1 Article no.: 350033 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Tel.: +49 / 40 / 39 82 07 0 Fax: +49 / 40 / 39 06 339 Table of contents

More information

NVM-2000 Activating NVM-H/M

NVM-2000 Activating NVM-H/M NVM-2000 Activating NVM-H/M Part No. 17526AHOSINS02 Issue 1-0, April 2001 This manual has been developed by NEC America, Inc. It is intended for the use of its customers and service personnel, and should

More information

IDEA. User s Guide. Part No IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183)

IDEA. User s Guide. Part No IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183) IDEA User s Guide Part No. 17500IDE02 Issue 1-0, April 1995 Printed in U.S.A. (183) 4 FOREST PARKWAY, SHELTON, CONNECTICUT 06484 TEL: 203-926-5400 FAX: 203-929-0535 This manual has been developed by Nitsuko

More information

Onyx VS Base Release Notes

Onyx VS Base Release Notes Onyx VS Base 03.00-04.00 Release Notes This manual has been developed by NEC America, Inc. It is intended for the use of its customers and service personnel, and should be read in its entirety before attempting

More information

NPort 6150/6250 Series Quick Installation Guide

NPort 6150/6250 Series Quick Installation Guide NPort 6150/6250 Series Quick Installation Guide Edition 10.0, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax:

More information

Empowered by Innovation. Unified Messaging. P/N July 2006 Printed in U.S.A.

Empowered by Innovation. Unified Messaging. P/N July 2006 Printed in U.S.A. Empowered by Innovation Unified Messaging P/N 1770083 July 2006 Printed in U.S.A. This manual has been developed by NEC Unified Solutions, Inc. It is intended for the use of its customers and service personnel,

More information

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL Windows 2000 Platform Description and Installation Instructions This manual has been developed by NEC America, Inc. It is intended for the use

More information

Select a Data Communication Interface

Select a Data Communication Interface Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The

More information

28i and 124i Release Notes for 28i Software 5.07, 124i Base Software 5.07 and 124i EXCPRU Software 5.07

28i and 124i Release Notes for 28i Software 5.07, 124i Base Software 5.07 and 124i EXCPRU Software 5.07 28i and 124i Release Notes for 28i Software 5.07, 124i Base Software 5.07 and 124i EXCPRU Software 5.07 P/N 92601RNT38 Issue 1-0, October 1999 Printed in U.S.A. This manual has been developed by Nitsuko

More information

PCI Configuration Setup for First Time FAX Card Installation. Part No WNG02 Issue 1-0, February 1998

PCI Configuration Setup for First Time FAX Card Installation. Part No WNG02 Issue 1-0, February 1998 PCI Configuration Setup for First Time FAX Card Installation Part No. 17580WNG02 Issue 1-0, February 1998 4 FOREST PARKWAY, SHELTON, CONNECTICUT 06484 TEL: 203-926-5400 FAX: 203-929-0535 This manual has

More information

28i and 124i Release Notes for 28i Software 5.08, 124i Base Software 5.08 and 124i EXCPRU Software 5.08

28i and 124i Release Notes for 28i Software 5.08, 124i Base Software 5.08 and 124i EXCPRU Software 5.08 28i and 124i Release Notes for 28i Software 5.08, 124i Base Software 5.08 and 124i EXCPRU Software 5.08 P/N 92601RNT39 Issue 1-0, Febuary 2000 Printed in U.S.A. This manual has been developed by Nitsuko

More information

WiFi to RS-232 adapter user manual

WiFi to RS-232 adapter user manual WiFi to RS-232 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight: 126

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Remote Maintenance of Controllers via Serial Port

Remote Maintenance of Controllers via Serial Port Remote Maintenance of Controllers via Serial Port Introduction This application notes describes the procedure for establishing communication between a PC with JetSym and a remote Jetter controller via

More information

NPort 6600 Series Quick Installation Guide

NPort 6600 Series Quick Installation Guide NPort 6600 Series Quick Installation Guide Edition 10.0, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Empowered by Innovation. Desktop Call Control. P/N July 2006 Printed in U.S.A.

Empowered by Innovation. Desktop Call Control. P/N July 2006 Printed in U.S.A. Empowered by Innovation Desktop Call Control P/N 1770084 July 2006 Printed in U.S.A. This manual has been developed by NEC Unified Solutions, Inc. It is intended for the use of its customers and service

More information

UPort 1200/1400/1600 Quick Installation Guide

UPort 1200/1400/1600 Quick Installation Guide 1200/1400/1600 Quick Installation Guide USB-to-Serial Converter Edition 9.0, November 2018 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM24x Quick-Connect Industrial Modem. User s Manual ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of

More information

3.1 I-7560 Pin Assignment and Specifications: Introduction

3.1 I-7560 Pin Assignment and Specifications: Introduction 3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows

More information

Bluetooth RS232 Serial Adapter

Bluetooth RS232 Serial Adapter Bluetooth RS232 Serial Adapter LM058 Table of contents 1. Introduction Page 1 2. Features Page 1 3. Packaging Page 2 4. General Specification Page 2 5. RS232 Interface Page 3 5.1 Pin Out Page 3 5.2 Signals

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information

Installation and User Guide

Installation and User Guide Installation and User Guide Trademarks and Notices Notice Comtrol Corporation. SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS OF THIS PRODUCT FOR A PARTICULAR PURPOSE. Comtrol

More information

Cable and Port Specifications

Cable and Port Specifications APPENDIXC This appendix provides cable and port specifications, and includes the following sections: Cables and Adapters Provided, page C-1 Console Port, page C-2 COM1 Port, page C-3 MGMT 10/100/1000 Ethernet

More information

LM058 Bluetooth Serial Adapter

LM058 Bluetooth Serial Adapter LM058 Bluetooth Serial Adapter with external antenna The LM058 Bluetooth Serial Adapter eliminates your conventional RS232 serial cables, providing an easy-to-use, invisible connection with freedom of

More information

UPort 1200/1400/1600 Quick Installation Guide

UPort 1200/1400/1600 Quick Installation Guide 1200/1400/1600 Quick Installation Guide USB-to-Serial Converter Edition 8.0, November 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc. IML 560 USER GUIDE Low Power 56Kbps Industrial modem Version 1.2 December 6, 2002 AYANTRA Inc. Revision History Date Version Description By November 18, 2002 1.1 Initial Release - December 6, 2002 1.2

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications

USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual. Features & Specifications. Specifications USBG-8COM-PRO 8-Port USB to RS-232, 422, 485 Auto Setup Adapter Manual The USBG-8COM-PRO 2-Port Series Industrial I/O Adapters are advanced USB to Serial Adapters that connect to 1, 2, 4 or 8 RS- 232/422/485

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

ExpressCard Serial Adapters User s Manual SSPXP-100 DSPXP-100 QSPXP-100 SSPXP-200/300 DSPXP-200/300 QSPXP-200/300

ExpressCard Serial Adapters User s Manual SSPXP-100 DSPXP-100 QSPXP-100 SSPXP-200/300 DSPXP-200/300 QSPXP-200/300 ExpressCard Serial Adapters User s Manual SSPXP-100 DSPXP-100 QSPXP-100 SSPXP-200/300 DSPXP-200/300 QSPXP-200/300 SSPXP/DSPXP/QSPXP-100/200/300 User s Manual P/N: 940-5000-100G Rev. 1.00 July 2007 International

More information

Bluetooth TO Serial CONVERTER E-P132-B

Bluetooth TO Serial CONVERTER E-P132-B Bluetooth TO Serial CONVERTER E-P132-B 1 Table of Contents Introduction..3 Package checklist...4 Product Specification...5 Product Panel Views Description...6 Product Views. 6 DC-In Power Outlet 6 Antenna

More information

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel

More information

Sender Receiver Sender

Sender Receiver Sender EEE 410 Microprocessors I Spring 04/05 Lecture Notes # 19 Outline of the Lecture Interfacing the Serial Port Basics of Serial Communication Asynchronous Data Communication and Data Framing RS232 and other

More information

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual Bluetooth to RS-232 Converter RT-132B Bluetooth Adaptor Operation Manual First Edition, Nov 2007 Table of Contents 1. Introduction.. 2 2. Package checklist.. 3 3. Product Specification... 4 4. Product

More information

4-Button IP Keyset User Guide. Technical Support Web Site: (registration is required) Empowered by Innovation

4-Button IP Keyset User Guide. Technical Support Web Site:  (registration is required) Empowered by Innovation Empowered by Innovation 4-Button IP Keyset User Guide Technical Support Web Site: http://ws1.necii.com (registration is required) P/N 0893404 Rev 2, September 2006 Printed in U.S.A. 5.97 This manual has

More information

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI.

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI. Mini USB to RS-232 Serial Adapter DB-9 Male Converter Product Manual Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI 2 USBG-232MINI PRODUCT MANUAL Revision History Revision Date Author Comments

More information

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack) Bluetooth v.0, v. RS Serial Adapter Revised 8/NOV/0.mm mm mm Features World s smallest Bluetooth Serial Adapter (RS) Bluetooth v.0, v. wireless technology 8 dbm Tx Power and -8 dbm Rx Sensitivity Serial

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network. LES302A LES302A-KIT LES302AE-KIT 2-Port 10/100 Device Server RS-232/422/485 DB9 M Quick Start Guide Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network. Customer Support Information

More information

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack) Bluetooth v2.0, v2. RS232 Serial Adapter - SMA Connector Revised 3/MAR/20 Datasheet Version.0 mm mm 34mm Features Bluetooth v2.0, v2. wireless technology dbm Tx Power and - dbm Rx Sensitivity Serial (RS232)

More information

CMM 900-3W USER GUIDE

CMM 900-3W USER GUIDE CMM 900-3W USER GUIDE AMPS Cellular Modem Module (3W) Page 1 of 1 Table of Contents 1. PRODUCT OVERVIEW...3 1.1 Features:... 3 1.2 Serial Port Pins:... 5 1.3 Applications:... 5 1.4 Your package includes:...

More information

How to connect. Go to Tools / Options / Port Settings (in PlusConfig software) and change the COM port to COM 3. Minelec PlusConfig How to connect

How to connect. Go to Tools / Options / Port Settings (in PlusConfig software) and change the COM port to COM 3. Minelec PlusConfig How to connect How to connect PlusConfig How to connect with the Luxom system There are 3 different ways of connecting your computer to the Luxom system: - LOCAL - IP - MODEM LOCAL This means that we use a Luxom serial

More information

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4 USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4 2 USBG-BAY4 Product Manual Revision History Revision Date Author

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED NTI R NETWORK TECHNOLOGIES INCORPORATED 1275 Danner Dr Aurora, OH 44202 Tel:330-562-7070 Fax:330-562-1999 www.nti1.com KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE KEEMUX Series MAN049

More information

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

AB300-Series Automated Filter Wheels

AB300-Series Automated Filter Wheels AB300-Series Automated Filter Wheels User Manual 1049478 August 2006 1. Introduction 1.1 Mission Statement Our mission is to provide our customers with reliable products, on time, and at a fair price.

More information

Cable and Port Specifications

Cable and Port Specifications Send documentation comments to mdsfeedback-doc@cisco.com APPENDIXC This appendix includes the cables and connectors used with the Cisco MDS 9100 Series Fixed Configuration Fabric Switch, and it includes

More information

OnCell G3100 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

UPort TM 1100 Series Quick Installation Guide

UPort TM 1100 Series Quick Installation Guide UPort TM 1100 Series Quick Installation Guide Edition 6.0, September 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

RM024 DVK USER GUIDE VERSION 1.2

RM024 DVK USER GUIDE VERSION 1.2 USER GUIDE VERSION 1.2 Americas: +1-800-492-2320 Asia: +852-2923-0610 REVISION HISTORY Version Revision Date Change Description Approved By 1.0 20 Dec 2012 Initial Release Chris Downey 1.1 15 Apr 2014

More information

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999 Hardware Manual 232 232232 PCMCIA 1 Port RS232 1.1 EDITION APRIL 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided

More information

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX. STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Package Includes/System Requirements PACKAGE INCLUDES

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This section describes the Catalyst 4224 Access Gateway Switch ports and the cables and adapters used to connect the switch to other devices. This section includes the following topics: Console

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

NVM-2e Installation Instructions and Release Notes for Versions 1.08, , and 1.20

NVM-2e Installation Instructions and Release Notes for Versions 1.08, , and 1.20 NVM-2e Installation Instructions and Release Notes for Versions 1.08, 1.08.02, and 1.20 Part No. 17780INS06 Issue 1-0, June 2000 This manual has been developed by Nitsuko America. It is intended for the

More information

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. SC10B is Bluetooth V.2.0-certified and is backward compatible with v1.1/1.2 devices. You can connect between your computers (Master)

More information

NPort 5100 Series Quick Installation Guide

NPort 5100 Series Quick Installation Guide NPort 5100 Series Quick Installation Guide Edition 4.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M USB 2.0 4-Port USB Serial DB-9 RS-232 Adapter FTDI Chipset Product Manual Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M 2 USB2-4COM-M PRODUCT MANUAL Revision History Revision Date Author

More information

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM. 8 Port USB to RS- 232/422/485 Octal Adapter Product Manual Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM 2 USB-8COMi-RM Product Manual Revision History Revision Date Author Comments

More information

NPort S8000 Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide NPort S8000 Series Quick Installation Guide Edition 6.0, March 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an

More information

704i Release Notes for Software Version

704i Release Notes for Software Version 704i Release Notes for Software Version 1.01.09 Technical Support Web Site: http://208.141.100.36 (registration is required) This manual has been developed by NEC America. It is intended for the use of

More information

RS-232 Connector Pin Assignments

RS-232 Connector Pin Assignments APPENDIXB This appendix lists the connector pin assignments for the CDEs, and includes the following sections: Serial Console-Interface, page B- Ethernet, page B- Cable Pin Assignments, page B- Serial

More information

XN120 PC Pro with Quick Installer Guide Rev 1.2 (September 2005)

XN120 PC Pro with Quick Installer Guide Rev 1.2 (September 2005) This guide explains the PC programming tool with Quick Installer for the XN120 Telephone System. There is also a separate guide (991425-5 PCPro Getting Started Guide) that explains the operation of PCPro

More information

Matrix-605 WinCE ARM9 Industry Box Computer User Guide

Matrix-605 WinCE ARM9 Industry Box Computer User Guide Matrix-605 WinCE ARM9 Industry Box Computer User Guide Version 1.1 Copyright Artila Electronics Co., Ltd. All Rights Reserved. Table of Contents 1. Introduction... 1 1.1 Features... 1 1.2 Packing List...

More information

Appendix A Cable Pinouts

Appendix A Cable Pinouts Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules

More information

PCL Port RS-232 Interface Card

PCL Port RS-232 Interface Card PCL-858 8-Port RS-232 Interface Card Copyright Notice This documentation and the software included with this product are copyrighted 2001 by Advantech Co., Ltd. All rights are reserved. Advantech Co.,

More information

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 1.0 Introduction A Technical Application Note from Doppler Systems April 11, 1999 Version 3.x of the DDF6000, running

More information

Cytron USB to UART Converter UC00A

Cytron USB to UART Converter UC00A Cytron USB to UART Converter UC00A User s Manual V1.1 August 2009 Information contained in this publication regarding device applications and the like is intended through suggestion only and may be superseded

More information

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual First Edition, June 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. MGate EIP3000

More information

Updating Reader Firmware

Updating Reader Firmware SWH-xxxx Readers Updating Reader Firmware Version C0 Document Part Number UM-096 July 2012 OVERVIEW This document describes how to download new firmware to Software House SWH-4xxx readers. The procedure

More information

An ISO-9001 Certified Company

An ISO-9001 Certified Company USER MANUAL MODEL 1002 and 1002S Asynchronous 2-Wire / Coax Short Range Modem An ISO-9001 Certified Company Part #07M1002-C Doc. #050011UC Revised 4/28/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT

More information

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2 USB to RS-232 Converter Part Number: USB-232-1 Communications made easy CONTENTS INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE..

More information

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB APPENDIXB This appendix lists the cable specifications for supported modules on the Cisco 7600 series router. The following signal summaries are contained in this appendix: Interface Specifications, page

More information

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China. FCC Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection

More information

Moxa TCC-100 Series Hardware Installation Guide

Moxa TCC-100 Series Hardware Installation Guide Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide

More information

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US I-7560U/7561U/7563U User Manual USB tto RS--232//422//485 Converrtterrss Verr.. 1..0,, Decc.. 2013 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of

More information

Cable Pinouts. SRP I/O Module

Cable Pinouts. SRP I/O Module Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4

More information

DGH A3000 Configuration Guide For use with DGH Modules

DGH A3000 Configuration Guide For use with DGH Modules DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation

More information

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual 12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrolscom The Analyst RS422/RS232 Tester (Standard Model) User Manual Manual Revision 102506 Table of Contents

More information

Cabling Guide for Console and AUX

Cabling Guide for Console and AUX Page 1 of 13 Cabling Guide for and AUX Ports TAC Notice: What's Changing on TAC Web Help us help you. Contents Introduction Before You Begin Conventions Prerequisites Components Used Table of Routers with

More information

User Guide. Date Apr BlueEva+C11/G2. Stollmann. E + V GmbH. User Guide

User Guide. Date Apr BlueEva+C11/G2. Stollmann. E + V GmbH. User Guide Version r02 Date Apr 2009 Author: ta Date saved: 06.04.09 Ref: BlueEva+C11G2_User_Guide_r02.doc Revision: r02 Page 1 of 22 Note This device was developed for the purpose of communication in an office environment.

More information

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800 WTI Part No. 12348 Rev. B CPM Series Control Port Manager Models CPM-1600 and CPM-800 User's Guide 5 Sterling Irvine California 92618 (949) 586-9950 Toll Free: 1-800-854-7226 Fax: (949) 583-9514 http://www.wti.com

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 60 Installation Guide September 00 - Ref: I60IE010-1 Model AX3000/M60 The reproduction of this material, in part or whole, is strictly prohibited. For additional

More information

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... User's Manual Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... 8 Important Safety Instructions... 9 Installation...11

More information

Default Mailbox List [ ] Indicates Aspire Mail, Aspire Mail FMS+, and UltraMail capacities.

Default Mailbox List [ ] Indicates Aspire Mail, Aspire Mail FMS+, and UltraMail capacities. The Aspire Mail, Aspire Mail FMS+, Aspire Mail Plus, and Aspire Mail DMS are for Aspire only. Aspire Mail and Aspire Mail FMS+ use a compact flash card. Aspire Mail Plus and Aspire Mail DMS use a hard

More information

Hidex Modem Installation Guide

Hidex Modem Installation Guide GE Security Hidex Modem Installation Guide P/N 460386001A ISS 17DEC07 Copyright Copyright 2007 GE Security, Inc. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced

More information

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem ZM56 High-Speed Industrial Modem Command Summary 1 ZM56 High-Speed Industrial Modem AT Command Summary Command AT ATA ATDT ATE0 ATE1 ATH ATH1 ATI ATO ATS Description Attention Prefix Precedes all commands

More information

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7 ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...10

More information

Tel: Fax:

Tel: Fax: NP302 Series 2-port RS-232 232/485/422 to Ethernet Serial Server User manual Shenzhen 3onedata Technology Co.,Ltd Tel: +86-755-26702688 Fax: +86-755-26703485 www.3onedata.com Contents 1. Introduction...

More information

Bluetooth RS-232 Dongle. User s Manual BTS-100

Bluetooth RS-232 Dongle. User s Manual BTS-100 Bluetooth RS-232 Dongle User s Manual BTS-100 Table of Contents 1. INTRODUCTION... 2 2. PHYSICAL DIAGRAM... 3 3. BLUETOOTH PAIRING AND CONNECTING... 4 4. RS-232 INSTALLATION... 10 5. HYPERTERMINAL SETTING

More information

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation 765289 USB to DB25 RS232 Adapter User Manual The USB Serial Adapter is designed to make serial port expansion quick and simple. Connecting to a USB port on your computer or USB hub, the USB Serial Adapter

More information

MGate MB3000 Modbus Gateway User Manual

MGate MB3000 Modbus Gateway User Manual MGate MB3000 Modbus Gateway User Manual Sixth Edition, July 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. MGate MB3000 Modbus Gateway User s Manual The software described in this manual

More information

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter 1. Package content: BLE RS-232 adapter Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232D-E Package Contents: BLE RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box: 11 x 6 x 5 (cm)

More information

QSC(LP)-100. User's Manual

QSC(LP)-100. User's Manual QSC(LP)-100 Four Channel Low Profile RS-232 Asynchronous Communications Adapter for PCI bus User's Manual QUATECH, INC. TEL: (330) 655-9000 5675 Hudson Industrial Parkway FAX: (330) 655-9010 Hudson, Ohio

More information

NPort 5400 Series Quick Installation Guide

NPort 5400 Series Quick Installation Guide NPort 5400 Series Quick Installation Guide Edition 7.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

User s Manual INT131

User s Manual INT131 User s Manual INT131 3434.502.02 Version 1.2 Edition November 2007 CAUTION Protect the equipment against splashing, rain and excessive sun rays. Never use the device if it is damaged or insecure. Do not

More information