Building a Next Generation Data Logging System
|
|
- Nelson Stokes
- 6 years ago
- Views:
Transcription
1 1
2 Building a Next Generation Data Logging System Fanie Coetzer, Field Sales Engineer Northern South Africa
3 Outline Introduction to the Next Generation of Data Logging Signals and Signal Conditioning Data Logging Hardware Platforms Data Logging Software Timing, Triggering, and Synchronization Logging Data Visualizing Data 3
4 The History of Data Logging Telegraph Chart Recorder Digital Data Logger
5 Moore s Law at Work in Data Logging Transistor count by date of introduction We foresee the need for DAQ systems that not only acquire data over a network, server, or PCs but also provide intelligence to help with the decision-making process. Mariano Kimbara, Senior Research Analyst, Frost & Sullivan 5
6 Moore s Law at Work in Data Logging Hard Drive Price Per Gigabyte $ Apple: 5 $3,500 $ $ Seagate: 1 $849 $ $ $10.00 $1.00 $0.10 Seagate: 750 $200 $
7 Next Generation Data Logging System Take advantage of the latest COTS technologies Device 1 Device 2 Timing Controller Data Bus Intel CPU Memory Controller Nonvolatile Storage Processors Storage ADC Bus Technology FPGA 7
8 Future Capabilities of Next Generation Logging Systems Visualization Ability to quickly create custom user interfaces on tablets and smart phones Application Software Software customizable on mobile devices Storage Increased storage capacity and logging to the cloud I/O Rates and Timing Faster rates and more custom timing options Processing More advanced inline analysis and signal processing Connectivity Better wireless connectivity and synchronization (Wi-Fi, cellular, Ethernet, IEEE 1588) Size and Ruggedness Smaller, more rugged systems based on Intel s Atom and ARM 8
9 Building a Next Generation Data Logging System Condition Monitoring System Requirements: Measure vibration, speed, and temperature Rugged, stand-alone system Flexible software for custom user interface Correlate all measurement to same timebase Log data to local nonvolatile storage Integrate video streaming synchronized to sensor data View and manage data in a simple tool Playback all sensor data and video side-by-side 9
10 Mixed-Measurement Applications Are Diverse Vibration Torque Displacement Pressure Temperature Force Strain 10
11 Building a Next Generation Data Logging System Choose My Sensors and Signal Conditioning Sensor, Etc. Signal Conditioning Temperature: 2 x Thermocouples Amplification, Cold-Junction Compensation, Filtering Vibration: 2 x IEPE Accelerometers Amplification, IEPE Excitation, Filtering, AC Coupling Video: 1 x Camera None 11
12 Building a Next Generation Data Logging System Condition Monitoring System Requirements: Measure vibration, speed, and temperature Rugged, stand-alone system Flexible software for custom user interface Correlate all measurement to same timebase Log data to local nonvolatile storage Integrate video streaming synchronized to sensor data View and manage data in a simple tool Playback all sensor data and video side-by-side 12
13 Overview of NI Data Logging Platforms Stand-Alone NI CompactDAQ CompactRIO PXI Embedded Measurements Measurements with Control High-Performance Measurements Mix and match a variety of modules, designed for continuous, stand-alone measurements Design a measurement system with highly customizable onboard timing and signal processing Optimize for high-channel count systems and tight synchronization 13
14 What is Stand-Alone NI CompactDAQ? Embedded Controller Chassis (NI-STC3) C Series I/O C Series I/O C Series I/O 14
15 NI C Series I/O Modules Integrated DAQ, Signal Conditioning, & Connectivity Built-in Signal Conditioning Direct connection to sensors for temperature, pressure, acceleration, strain, load cell, current and so on High Quality Measurements Streaming up to 1 MS/s and 24-bit resolution Guaranteed Accuracy NIST traceable calibration Signal to Backplane Isolation Barrier Safety, noise immunity, common mode rejection 15
16 Building a Next Generation Data Logging System Choose My Platform and Modules Web Cam Thermocouples Accelerometers Tachometer Stand-alone NI CompactDAQ System: cdaq-9139 C Series Modules: NI 9211, NI
17 Building a Next Generation Data Logging System Condition Monitoring System Requirements: Measure vibration, speed, and temperature Rugged, stand-alone system Flexible software for custom user interface Start acquisition off of a hardware trigger Correlate all measurement to same timebase Log data to local nonvolatile storage Integrate video streaming synchronized to sensor data View and manage data in a simple tool Playback all sensor data and video side-by-side 17
18 LabVIEW Has Been Proven Over Nearly 30 Years Withstanding the test of time across operating systems, buses, technologies, and more 18
19 Accelerate Your Productivity With LabVIEW Unified Software Solution Manage and organize all system resources in a single software environment. Hardware Connectivity Bring real-world signals into LabVIEW from any I/O on any instrument. Deployment Targets Deploy LabVIEW code to the leading desktop, real-time, and FPGA hardware targets. Parallel Programming Easily create independent loops that automatically execute in parallel. Convey With a Clear UI Create modern user interfaces to display measurements and results. Measure in Minutes Reduce development time with abundant sample projects and templates. Integrate Existing Code Combine and reuse.m files, C code, and HDL with graphical code. Analysis Libraries Use built-in high-performance analysis libraries designed for measurement applications. LabVIEW abstracts low-level complexity and integrates all of the tools engineers and scientists need to build any measurement or control system. 19
20 Chameleon for NI CompactDAQ by PVI Systems For Structural Test and Monitoring Applications Configuration-based software, powered by LabVIEW Acquire static and dynamic signals Measures voltage, current, vibration, strain, and temp Runs directly on stand-alone NI CompactDAQ Supports over 20 modules and USB, Ethernet, and stand-alone chassis "Using Chameleon turnkey software based on NI LabVIEW and DAQ software, we can measure more than 32 channels of pressure data from our sensors with expansion capabilities while maintaining time-synchronized data from transient shot events on the firing range. -Raytheon BBN 20
21 Building a Next Generation Data Logging System Choose My Software Web Cam Thermocouples Accelerometers Tachometer Stand-alone NI CompactDAQ System: cdaq-9139 C Series Modules: NI 9211, NI 9234 LabVIEW System Design Software 21
22 Building a Next Generation Data Logging System Condition Monitoring System Requirements: Measure vibration, speed, and temperature Rugged, stand-alone system Flexible software for custom user interface Start acquisition off of a hardware trigger Correlate all measurement to same timebase Integrate video streaming synchronized to sensor data View measurements remotely from tablet Log data to local nonvolatile storage View and manage data in a simple tool Playback all sensor data and video side-by-side 22
23 NI CompactDAQ Timing Basics Analog input, analog output, digital input, digital output tasks Sample Clock can be generated from internal or external source Timing Option Finite Samples Continuous Samples Hardware-Timed Single Point Description Acquire or generate a configurable number of samples at a configurable rate. Acquire or generate samples continuously, until explicitly stopped by the API. Acquire or generate samples continuously on the edge of a hardware clock. 23
24 7 Hardware-Timed Streams Built-In Timing Engines - 3 Analog Input - 1 Analog Output - 1 Digital Input - 1 Digital Output Additional Timing Sources - Counter/Timers - External PFI Lines 24
25 Demo 1: LabVIEW and Data Acquisition
26 Building a Next Generation Data Logging System Condition Monitoring System Requirements: Measure vibration, speed, and temperature Rugged, stand-alone system Flexible software for custom user interface Start acquisition off of a hardware trigger Correlate all measurement to same timebase Log data to local nonvolatile storage Integrate video streaming synchronized to sensor data View measurements remotely from tablet View and manage data in a simple tool Playback all sensor data and video side-by-side 26
27 Reducing Logged Data with Event-Based Logging Anomaly Detected Anomalous event could trigger adjusted data acquisition behavior, e.g. faster data rates Post-Trigger Data Data acquired after a detected event is often logged with more granularity than pre-trigger data Pre-Trigger Data Data acquired before an event can be stored in a buffer and later logged or simply discarded Discarded Data Historical data exceeding the length of the buffer is discarded 27
28 File Format Comparison ASCII Binary XML Database TDMS Exchangeable Small Disk Footprint Footprint Searchable Inherent Attributes Attributes High-Speed Streaming Streaming 28
29 TDMS File Format Single streaming binary file Data MyFile.tdms Set (File) Property Author = 1 John Smith Property Description n = Test Drive Channel Test Run Group(s) #1 Three levels of hierarchy for better organization File, groups, and channels Property Vehicle = 1 Malibu Property Track = East 2 Property Road_Surface n = Paved Engine Channel(s) Temperature Property TC_Type 1 = J Property Units = Deg n C Customizable, descriptive properties at each level Extensible and Scalable 29
30 Where should you save data? Onboard Storage USB Thumb Drive USB HDD USB SSD Ethernet or Cloud Storage Onboard Fastest Advantages Removable, swappable Price per GB Fast throughput Removable, swappable Large capacity Fast throughput Removable, swappable No moving parts Extended temperature Large capacity Considerations Data access and retrieval Limited disk space Slower throughput Susceptible to vibration Smaller capacities Price per GB Network connectivity Security 30
31 Cloud Technologies Web-Based Thin Clients Data Dashboard for LabVIEW Data Cloud Desktop Applications LabVIEW Stand-Alone NI CompactDAQ 31
32 Vision Integration with NI CompactDAQ IP Security Cameras Supported brands: Basler Vision Technologies Axis Communications Compressed images 1-5 frames per second (depending on resolution) Machine Vision, Scientific, Specialty Cameras Available on Stand-Alone NI CompactDAQ Full-frame rate, uncompressed images GigE Vision, EtherNet, USB options 32
33 Demo 2: TDMS Logging and Video Integration
34 Building a Next Generation Data Logging System Condition Monitoring System Requirements: Measure vibration, speed, and temperature Rugged, stand-alone system Flexible software for custom user interface Start acquisition off of a hardware trigger Correlate all measurement to same timebase Log data to local nonvolatile storage Integrate video streaming synchronized to sensor data View measurements remotely from tablet View and manage data in a simple tool Playback all sensor data and video side-by-side 34
35 Flexible Visualization Options with Stand-Alone NI CompactDAQ Headless Mobile Local Remote 35
36 Industry Trend: Integrating Mobile Devices Data Dashboard for LabVIEW Control and visualize data from LabVIEW systems on a tablet 36
37 Data Management with NI DIAdem Ready to use data search and mining Easy, flexible access to databases and files Live data collection and display Interactive analysis and report generation Automation through VBScript 37
38 Demo 3: Data Dashboard and Data Management
39 Building a Next Generation Data Logging System Condition Monitoring System Requirements: Measure vibration, speed, and temperature Rugged, stand-alone system Flexible software for custom user interface Start acquisition off of a hardware trigger Correlate all measurement to same timebase Log data to local nonvolatile storage Integrate video streaming synchronized to sensor data View measurements remotely from tablet View and manage data in a simple tool Playback all sensor data and video side-by-side 39
40 Future Capabilities of Next Generation Logging Systems Visualization Ability to quickly create custom user interfaces on tablets and smart phones Application Software Software customizable on mobile devices Storage Increased storage capacity and logging to the cloud I/O Rates and Timing Faster rates and more custom timing options Processing More advanced inline analysis and signal processing Connectivity Better wireless connectivity and synchronization (Wi-Fi, cellular, Ethernet, IEEE 1588) Size and Ruggedness Smaller, more rugged systems based on Intel s Atom and ARM 40
41 Thank you for attending Visit for more information
CompactDAQ Chassis PRODUCT FLYER CONTENTS. Цены и срок поставки уточняйте на сайте по телефону: или
PRODUCT FLYER CompactDAQ Chassis CONTENTS CompactDAQ Chassis Detailed View of cdaq-9189 Key Features NI-DAQmx Application Programming Interface (API) Platform-Based Approach to Conditioned Measurements
More informationAdvanced NI-DAQmx Programming Techniques with LabVIEW
Advanced NI-DAQmx Programming Techniques with LabVIEW Agenda Understanding Your Hardware Data Acquisition Systems Data Acquisition Device Subsystems Advanced Programming with NI-DAQmx Understanding Your
More informationGas Combustion Testing With LabVIEW
Gas Combustion Testing With LabVIEW Asa Kirby Senior Product Manager Taking Advantage of Trends in Product Test & Validation with LabVIEW Asa Kirby Senior Product Manager Abstract The growing complexity
More informationHands-On Seminar. Evaluate CompactDAQ and LabVIEW for Your Application 09/05/2017. ni.com
Hands-On Seminar Evaluate CompactDAQ and LabVIEW for Your Application 09/05/2017 ni.com Jason Strydom Technical Sales Engineer CLD Let s Talk About You What type of applications are you going to be working
More informationNI Technical Symposium ni.com
NI Technical Symposium 2016 1 New Hardware Technologies for DAQ Applications Nicholas Haripersad Field Sales Engineer Session Objectives Introduce the three major NI DAQ platforms Present future trends
More informationNew Technologies in Data Acquisition
New Technologies in Data Acquisition Agenda Introduction to PC Based Data Acquisition New Technologies in Data Acquisition 1. New Bus Technologies 2. Signal Conditioning, Timing and Synchronization Introduction
More informationSimplify System Complexity
Simplify System Complexity With the new high-performance CompactRIO controller Fanie Coetzer Field Sales Engineer Northern South Africa 2 3 New control system CompactPCI MMI/Sequencing/Logging FieldPoint
More informationA Review of PC-Based Data Logging and Recording
1 de 11 19/11/2008 16:45 Improve your ni.com experience. Login or Create a user profile. Document Type: Tutorial NI Supported: Yes Publish Date: Mar 1, 2007 A Review of PC-Based Data Logging and Recording
More informationHow to Choose the Right Bus for Your Measurement System
1 How to Choose the Right Bus for Your Measurement System Overview When you have hundreds of different data acquisition (DAQ) devices to choose from on a wide variety of buses, it can be difficult to select
More informationEthernet Data Acquisition System
Ethernet Data Acquisition System NI CompactDAQ Measure up to 256 channels of sensor, analog I/O, and digital I/O signals Choose from more than 50 hotswappable I/O modules with integrated signal conditioning
More informationDT9828. USB Powered Thermocouple Measurement Module. Key Features: Analog Input Channels
DT9828 USB Powered Thermocouple Measurement Module Key Features: 8 differential analog inputs for thermocouple or voltage measurements Support for B, E, J, K, N, R, S, and T thermocouple types One cold
More informationNI Smart Cameras PRODUCT FLYER CONTENTS. Have a question? Contact Us.
Have a question? Contact Us. PRODUCT FLYER NI Smart Cameras CONTENTS NI Smart Cameras Detailed View of ISC-178x Key Features Vision Software Hardware Services Page 1 ni.com NI Smart Cameras NI Smart Cameras
More informationIncrease Your Test Capabilities with Reconfigurable FPGA Technology
Increase Your Test Capabilities with Reconfigurable FPGA Technology CTEA Electronics Symposium Ryan Verret Senior Product Manager FPGA Technology for Test National Instruments Graphical System Design A
More informationSimplify System Complexity
1 2 Simplify System Complexity With the new high-performance CompactRIO controller Arun Veeramani Senior Program Manager National Instruments NI CompactRIO The Worlds Only Software Designed Controller
More informationIntroduction to LabVIEW and NI Hardware Platform
Introduction to LabVIEW and NI Hardware Platform Corrie Botha Platform-Based Approach 2 With LabVIEW, You Can Program the Way You Think 3 With LabVIEW, You Can Program the Way You Think The graphical,
More informationPXI Remote Control and System Expansion
Have a question? Contact Us. PRODUCT FLYER PXI Remote Control and System Expansion CONTENTS PXI Remote Control and System Expansion Components of a Remotely Controlled PXI System Choosing a Remote Control
More informationThe LabVIEW RIO Architecture and the Newest Member to the CompactRIO Family
The LabVIEW RIO Architecture and the Newest Member to the CompactRIO Family Brett Burger Sr. Product Manager What is CompactRIO? IP Camera GigE Camera Analog Frame Grabber Analog Camera Motor Drivers and
More informationC Series Analog Output Modules
C Series Analog Output Modules NI 9263, NI 9265 NEW! ±10 V and 0 to 20 ma analog output ranges, 16-bit resolution, 100 ks/s simultaneous update rate 4 channels per module Isolation up to 2,300 V rms (withstand),
More informationGraphical System Design for Machine Control
Graphical System Design for Machine Control Overview Embedded System Development for Machine Control Using a Single, Automated Graphical Programming Tool Chain and Programmable Automation Controllers (PACs)
More informationVXI-LXI DAQ System Ensures Mission Critical Reliability for Rocket Engine Test
VXI-LXI DAQ System Ensures Mission Critical Reliability for Rocket Engine Test by Tom Sarfi, VTI Instruments This rocket launch vehicle manufacturer is the world s largest producer of solid rocket motors
More informationFigure 3.174: Illustration of the code of the event f USB that plots an USB camera frame if the typed frame is under the acceptable limits (case 0)
107 Figure 3.174: Illustration of the code of the event f USB that plots an USB camera frame if the typed frame is under the acceptable limits (case 0) Typing the desired HS frame in the box f HS, it is
More informationVIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models
VIBBOX 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels VIBbox is a high-accuracy, high channel count, dynamic signal analyzer system for sound and vibration applications. Each
More informationA Step Into the Future of Data Measurement. Focus on Tests and Measurements. Let idaq Do the Rest.
W H I T E P A P E R A Step Into the Future of Data Measurement Focus on Tests and Measurements. Let idaq Do the Rest. idaq Whitepaper OVERVIEW IDAQ, THE INTUITIVE, COMPLETE AND RELIABLE SOFTWARE FOR YOUR
More informationVIBbox 64-Channel Sound & Vibration Solution
VIBbox 64-Channel Sound & Vibration Solution VIBbox is a high-accuracy, high channel count, dynamic signal analyzer system for sound and vibration applications. VIBbox packages four DT9857E modules in
More informationDeveloping Measurement and Analysis System using MATLAB
Developing Measurement and Analysis System using MATLAB 성호현차장 Senior Application Engineer MathWorks Korea 2013 The MathWorks, Inc. 1 Agenda Great Demo : Battery test demo Overview of data acquisition capabilities
More informationDesigning Real-Time Control Applications Using LabVIEW and CompactRIO. Developer Days 2009
Designing Real-Time Control Applications Using LabVIEW and CompactRIO Developer Days 2009 Agenda CompactRIO Overview Technology Applications Real-Time Control Software Architecture Basic Process Control
More informationDigital Camera Image Acquisition
NI PCI-1424, NI PCI-1422 NI PCI-1424 RS422, LVDS, or TTL area- and line-scan camera compatibility Full 8-, 10-, 12-, 14-, 16-, 24-, and 32-bit resolution (grayscale or color) 50 MHz pixel clock rate with
More informationAutomated Test Equipments
Automated Test Equipments Elias Nicolas National Instruments - Arabia Tests and Measurements Interactive Measurements Benchtop Non-programmed Automated Measurements Data Acq, Instr I/O Programmed Automated
More informationCHAPTER 3 LabVIEW REAL TIME APPLICATION DEVELOPMENT REFERENCES: [1] NI, Real Time LabVIEW. [2] R. Bishop, LabVIEW 2009.
CHAPTER 3 By Radu Muresan University of Guelph Page 1 ENGG4420 CHAPTER 3 LECTURE 1 October 31 10 5:12 PM CHAPTER 3 LabVIEW REAL TIME APPLICATION DEVELOPMENT REFERENCES: [1] NI, Real Time LabVIEW. [2] R.
More informationSensors lab. User Manual
Sensors lab User Manual Annotation This document is a user manual for laboratory-based practical on the discipline Measurement of physical quantities and includes: description of the educational laboratory
More informationDAQ SYSTEM FOR GYROLASER
Bachir Bouhadef 1 Analog input channels : Icw, Iccw and Sagnac @ 5 khz. Control parameters ( >10 ) @ 1 Hz. Sagnac Icw Iccw 2 NI PXI-8106 RT : 2.16 GHz Intel Core 2 Duo T7400 With LabVIEW Real-Time 3 What
More informationPC-based data acquisition II
FYS3240 PC-based instrumentation and microcontrollers PC-based data acquisition II Data streaming to a storage device Spring 2015 Lecture 9 Bekkeng, 29.1.2015 Data streaming Data written to or read from
More informationAcquiring Data from Sensors and Instruments Using MATLAB
Acquiring Data from Sensors and Instruments Using MATLAB Chirag Patel Application Engineer Control Systems MathWorks 2011 The MathWorks, Inc. 1 Agenda Why acquire data with MATLAB? Overview of data access
More informationLabVIEW Basics I: Introduction Course
www.ni.com/training LabVIEW Basics I Page 1 of 4 LabVIEW Basics I: Introduction Course Overview The LabVIEW Basics I course prepares you to develop test and measurement, data acquisition, instrument control,
More informationDT7837. ARM Module for Embedded Applications. Overview. Key Features. Supported Operating Systems
DT7837 ARM Module for Embedded Applications Overview The DT7837 is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements with an embedded Cortex-A8 600 MHz ARM
More informationWhat s New in LabVIEW 2018 and LabVIEW NXG
What s New in LabVIEW 2018 and LabVIEW NXG Swathi Madhavan Field Marketing Engineer, National Instruments ni.com Who Uses LabVIEW? Electronics and Industrial Machinery Aerospace and Defense Semiconductor
More informationPXI Digital Pattern Instruments
Have a question? Contact Us. PRODUCT FLYER PXI Digital Pattern Instruments CONTENTS PXI Digital Pattern Instruments Detailed View of PXIe-6570 Digital Pattern Instrument Key Features NI-Digital Pattern
More informationInstall the Software and Hardware
WHERE TO START WITH YOUR NI 4350/4351 This document explains how to begin using your National Instruments 4350/4351 high-precision temperature and voltage meters. The NI 4350/4351 (NI 435x) products include
More informationWhat s New in Data Acquisition
What s New in Data Acquisition NEW! New DAQ Products and Demos NEW! USB DAQ Multifunction Intelligent DAQ DAQ Software New DAQ Products and Demos NEW! USB DAQ Multifunction Intelligent DAQ DAQ Software
More informationHigh-Speed M Series Multifunction DAQ 16-Bit, up to 1.25 MS/s, up to 80 Analog Inputs
High-Speed M Series Multifunction DAQ 16-Bit, up to 1.25 MS/s, up to 80 Inputs NI M Series High-Speed NI recommends high-accuracy M Series for 5X more measurement sensitivity or industrial M Series for
More informationNI Technical Symposium 2016
NI Technical Symposium 2016 How can Modular Instruments reduce the Cost of Test? Fanie Coetzer Field Sales Engineer National Instruments Box Instruments 3 Box Inserting New Technology 1 2 3 4 5 6 7 8 5
More informationMOIS Overview. 1. Developer Walkthrough
MOIS Overview The Modular Ocean Instrumentation System (MOIS) software was developed in the LabVIEW programming language. The software runs on a LabVIEW real-time target. The National Instruments produced
More informationLabVIEW FPGA in Hardware-in-the-Loop Simulation Applications
LabVIEW FPGA in Hardware-in-the-Loop Simulation Applications Publish Date: Dec 29, 2008 38 Ratings 4.16 out of 5 Overview Hardware-in-the-loop (HIL) simulation is achieving a highly realistic simulation
More informationBE/EE189 Design and Construction of Biodevices Lecture 5. BE/EE189 Design and Construction of Biodevices - Caltech
BE/EE189 Design and Construction of Biodevices Lecture 5 LabVIEW Programming Data acquisition DAQ system Signals and signal conditioning Nyquist frequency NI ELVIS II NI-DAQmx and DAQ assistant LabVIEW
More informationDT7837 ARM Module for Embedded Applications
DT7837 ARM Module for Embedded Applications The DT7837 is a high accuracy dynamic signal acquisition module for noise, vibration, and acoustic measurements with an embedded Cortex-A8 600MHz ARM processor.
More informationComputerized Measurement systems
Elektrisk Mätteknik, LTH Computerized Measurement systems 1. Introduction to Computerized measurements systems By Tomas Jansson, some text excerpts from NI application note AN007 regarding signal conditioning,
More informationSoftware-Defined Test Fundamentals. Understanding the Architecture of Modular, High-Performance Test Systems
Software-Defined Test Fundamentals Understanding the Architecture of Modular, High-Performance Test Systems Contents Executive Summary 4 Architecture Layer No. 5: System Management/Test Executive 5 Architecture
More informationUsing PXI to Rapidly Develop Structural Test Systems for a Space Exploration Vehicle
Using PXI to Rapidly Develop Structural Test Systems for a Space Exploration Vehicle by Dave Baker, G Systems Submitted by National Instruments Introduction We successfully conducted the first structural
More informationNI CompactDAQ USB Data Acquisition Systems
Technical Sales (866) 531-6285 orders@ni.com Print E-mail this Page Open Document as PDF Ordering Information Detailed Specifications For user manuals and dimensional drawings, visit the product page resources
More informationIsolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW
Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES Single-channel isolated signal-conditioning modules. Accepts outputs from Thermocouple, millivolt, volt and current signals. Complete microcomputer-based
More informationMB Millenium Single- and Multi-Axis Vibration and Motion Control System
General Overview: The MB Millenium Dynamic Test Controller from MB Dynamics is a multiple-input, multiple-output (MIMO) and/or a multiple-input, single-output (MISO) dynamic test control system. It reliably
More informationA New Virtual Vibration and Temperature Test and Analysis Instrument of Wheel-Set Based on LabVIEW2011
Research Journal of Applied Sciences, Engineering and Technology 5(19): 4695-4700, 2013 ISSN: 2040-7459; e-issn: 2040-7467 Maxwell Scientific Organization, 2013 Submitted: September 26, 2012 Accepted:
More informationScientific Instrumentation using NI Technology
Scientific Instrumentation using NI Technology Presented by, Raja Pillai Technical Consultant and Field Engineer National Instruments Australia Pty. Ltd. NI s Platform-Based Approach 2 The LabVIEW RIO
More informationFYS Data acquisition & control. Introduction. Spring 2018 Lecture #1. Reading: RWI (Real World Instrumentation) Chapter 1.
FYS3240-4240 Data acquisition & control Introduction Spring 2018 Lecture #1 Reading: RWI (Real World Instrumentation) Chapter 1. Bekkeng 14.01.2018 Topics Instrumentation: Data acquisition and control
More informationDesigning Next Generation Test Systems An In-Depth Developers Guide
An In-Depth Developers Guide Designing Next Generation Test Systems An In-depth Developers Guide Contents Section 1 Executive Summary Chapter 1 Increasing Design Complexity...1-1 Shorter Product Development
More informationModernizing Power Grids with Distributed Intelligence and Smart Grid-Ready Instrumentation
1 Modernizing Power Grids with Distributed Intelligence and Smart Grid-Ready Instrumentation Steve McAlonan, National Instruments Business Development Manager, Eastern US Energy Segment Roberto Piacentini,
More informationPC-based data acquisition I
FYS3240 PC-based instrumentation and microcontrollers PC-based data acquisition I Spring 2016 Lecture #8 Bekkeng, 20.01.2016 General-purpose computer With a Personal Computer (PC) we mean a general-purpose
More informationAgenda. Programming FPGAs Why Are They Useful? NI FPGA Hardware Common Applications for FPGAs How to Learn More
Agenda Programming FPGAs Why Are They Useful? NI FPGA Hardware Common Applications for FPGAs How to Learn More FPGA Technology Programmable Interconnects Logic Blocks I/O Blocks FPGA Logic Implementation
More informationHigh-Speed M Series Multifunction DAQ 16-Bit, up to 1.25 MS/s, up to 80 Analog Inputs
High-Speed M Series Multifunction DAQ 16-Bit, up to 1.25 MS/s, up to 80 Inputs NI M Series High-Speed NI recommends high-accuracy M Series for 5X more measurement sensitivity and lowpass filtering 16,
More informationNational Instruments Approach
National Instruments Approach Our graphical programming software, LabVIEW, and modular, open hardware, has redefined how engineers work throughout the entire product design cycle. Committed to Engineers
More informationSBC-COMe FEATURES DESCRIPTION APPLICATIONS SOFTWARE. EnTegra Ltd Tel: 44(0) Web:
A Windows /Linux Embedded Single Board Computer with XMC IO Site FEATURES Combines an industry standard COM CPU module with an XMC IO module in a compact, stand alone design Scalable CPU performance from
More informationGo anywhere, test anything with edaq. the rugged DAQ system for mobile, stand-alone measurement
Go anywhere, test anything with edaq the rugged DAQ system for mobile, stand-alone measurement Intelligent Data Storage Rugged, Mobile Data Acquisition Rugged, mobile data acquisition The SoMat edaq sets
More informationMainframes. Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2. Please find further solutions in chapter DEWE2
Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Mainframes DEWETRON Mainframes are combining a ruggedized PC with signal conditioning, A/D card and software.
More informationHigh-Level Synthesis with LabVIEW FPGA
High-Level Synthesis with LabVIEW FPGA National Instruments Agenda Introduction NI RIO technology LabVIEW FPGA & IP Builder RIO Hardware Platform Application 2 An Ideal Embedded Architecture Processor
More informationni.com What s New in 2013
What s New in 2013 Code Reuse and Mobile Device Integration Access the Newest Hardware Technology Code Management and Debugging Tools All Systems. Go. New Sample Projects and Improved Examples Streamlined
More informationTitle: High-Volume Automated Production Test with NI CompactRIO. Author: Robert Hoffman Signal.X Technologies, LLC
Title: High-Volume Automated Production Test with NI CompactRIO Author: Robert Hoffman Signal.X Technologies, LLC Industry: Automotive, Automated Test Products: National Instruments LabVIEW, CompactRIO
More informationData Acquisition Fundamentals
-1001 MAINFRAME Application Note 007 Introduction Data Acquisition Fundamentals Today, most scientists and engineers use personal computers (PCs) with PCI, PXI/CompactPCI, PCMCIA, USB, IEEE 1394, ISA,
More informationEttus Research Update
Ettus Research Update Matt Ettus Ettus Research GRCon13 Outline 1 Introduction 2 Recent New Products 3 Third Generation Introduction Who am I? Core GNU Radio contributor since 2001 Designed
More informationHigh-Accuracy M Series Multifunction DAQ 18-Bit, up to 625 ks/s, up to 32 Analog Inputs
High-Accuracy M Series Multifunction DAQ 18-Bit, up to 625 ks/s, up to 32 Analog Inputs NI M Series High-Accuracy 16 or 32 analog inputs at 18 bits, 625 ks/s (500 ks/s scanning) Up to 4 analog outputs
More informationDeveloping Measurement and Control Applications with the LabVIEW FPGA Pioneer System
Developing Measurement and Control Applications with the LabVIEW FPGA Pioneer System Introduction National Instruments is now offering the LabVIEW FPGA Pioneer System to provide early access to the new
More informationCreate Without Limits: Add the Power of User-Programmable FPGAs to Your Test Applications
1 Create Without Limits: Add the Power of User-Programmable FPGAs to Your Test Applications Farris Alhorr Business Development Manager RF & Wireless Comm farris.alhorr@ The Parameters of Instrumentation
More informationHigh Performance Embedded Applications. Raja Pillai Applications Engineering Specialist
High Performance Embedded Applications Raja Pillai Applications Engineering Specialist Agenda What is High Performance Embedded? NI s History in HPE FlexRIO Overview System architecture Adapter modules
More informationThe data acquisition components, and their relationship to each other, are shown below.
Data acquisition system Part (1) Digital inputs output and counter You can think of a data acquisition system as a collection of software and hardware that connects you to the physical world. A typical
More informationDAQ Accessories Selection Guide
DAQ Accessories Selection Guide NI Cable Design Advantages National Instruments offers many different high-performance shielded cables that have been specially designed for specific NI multifunction DAQ
More informationWas ist neu in LabVIEW 2014
Was ist neu in LabVIEW 2014 Marcel Krenz http://www.>i- berlin.mpg.de/pc/labview 06.11.2014 Fritz- Haber Institute, Berlin Accurate Data Acquisition With the Latest Technology Extended Deployment Options
More informationWIRELESS ASSET MONITORING
WIRELESS ASSET MONITORING WITH ANALYSIS AND DYNAMIC DATA TRANSLATOR SOFTWARE WAM 661 WAM 761 WAM 56U Rev. 2.11 WAM WIRELESS ASSET MONITORING SYSTEM OVERVIEW: Spectrum Instruments Ltd s WAM product line
More informationThe Next Evolution of Instrumentation for Microwave Test. Jin Bains RF R&D Director National Instruments
The Next Evolution of Instrumentation for Microwave Test Jin Bains RF R&D Director National Instruments The Complexity of Testing Systems of Systems www.airbus.com www.esa.int EISCAT_3D A European 3D Imaging
More informationNI Linux Real-Time. Fanie Coetzer. Field Sales Engineer SA North. ni.com
1 NI Linux Real-Time Fanie Coetzer Field Sales Engineer SA North Agenda 1. Hardware Overview 2. Introduction to NI Linux Real-Time OS Background & Core Technology Filesystem Connectivity and Security 3.
More informationCONNECTING SENSORS TO DATA ACQUISITION SYSTEM ANALOG INPUTS
CONNECTING SENSORS TO DATA ACQUISITION SYSTEM ANALOG INPUTS Properly connecting sensors to a data acquisition system is as crucial as selecting the proper sensor for the application, and there are multiple
More informationConverter station water-cooled pump vibration monitoring and. condition assessment system based on LabVIEW
International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 2320-9364, ISSN (Print): 2320-9356 Volume 3 Issue 5 ǁ May 2015 ǁ PP.08-13 Converter station water-cooled pump vibration
More informationLabVIEW Tutorials. T.1 Temperature Measurement and Cold Junction Compensation (CJC) LUMS School of Science and Engineering
LabVIEW Tutorials T.1 Temperature Measurement and Cold Junction Compensation (CJC) LUMS School of Science and Engineering Umer Hassan & Muhammad Sabieh Anwar Introduction: In this tutorial we shall learn
More informationSpecification for temperature sensor calibration setup
1. Item description Automated Temperature calibration setup made of: A. High accuracy temperature bath with internal and external reference probe, multiple sensors insert kits, carry case and other accessories.
More informationData Acquisition in LabVIEW
University College of Southeast Norway Data Acquisition in LabVIEW Hans-Petter Halvorsen, 2016.10.28 http://home.hit.no/~hansha Preface This tutorial explains the basic concepts of a Data Acquisition in
More informationMultifunction DAQ Accessory and Cable Selection Guides
Multifunction DAQ Accessory and Cable Selection Guides NI Cable Design Advantages The cables designated EP are the most commonly used data acquisition device cables. Each type of cable is designed to work
More informationOBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal
More information1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller
SPECIFICATIONS crio-9040 1.30 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, Kintex-7 70T FPGA, 4-Slot CompactRIO Controller Definitions Warranted specifications describe the performance of a model under
More informationA Smart Network Sensor System for Distributed, Synchronous Data Acquisition
A Smart Network Sensor System for Distributed, Synchronous Data Acquisition Alex Karolys President, and Fernando GenKuong Engr. Director VIP Sensors, Inc. 27128A Paseo Espada, St. 1523 - San Juan Capistrano,
More informationTemperature Measurement Instruments Ultra-Accurate... by Design
TEMPpoint Type: Temperature Measurement Instrument Temperature Measurement Instruments Ultra-Accurate... by Design TEMPpoint is a family of temperature measurement instruments designed for high accuracy
More informationNI Vision Platform. Radim ŠTEFAN. ni.com
NI Vision Platform Radim ŠTEFAN www./vision National Instruments Our Stability Revenue: $1.15B in 2012 Innovation: 18% re-invested to R&D Global Operations: Approximately 7,100 employees; operations in
More informationUltra-Accurate Measurement for Temperature and Voltage
Ultra-Accurate Measurement for Temperature and Voltage MEASURpoint is an ultra-accurate instrument for measuring any combination of thermocouple, RTD, and voltage inputs. MEASURpoint is available as a
More informationDesign Concepts For A 588 Channel Data Acquisition & Control System
Design Concepts For A 588 Channel Data Acquisition & Control System Kenneth H. Bosin, Spectral Dynamics Inc. This paper discusses the design methods used to create a data acquisition and control system
More informationFPGA design with National Instuments
FPGA design with National Instuments Rémi DA SILVA Systems Engineer - Embedded and Data Acquisition Systems - MED Region ni.com The NI Approach to Flexible Hardware Processor Real-time OS Application software
More informationEmbedded Vision Systémy - využití ve výuce a v průmyslu
Embedded Vision Systémy - využití ve výuce a v průmyslu Radim ŠTEFAN NI Embedded Vision NI Smart Cameras NI CVS Compact Vision System NI EVS Embedded Vision System 2 NI Embedded Vision - continued NI CompactRIO
More informationHigh-Value PXI Embedded Controller for Windows. High-Value Embedded Controllers for PXI Express NI PXI-8101, NI PXI NI PXIe-8101, NI PXIe-8102
High-Value PXI Embedded Controller for Windows NI PXI-8101, NI PXI-8102 2.0 GHz single-core for PXI-8101, 1.9 GHz dual-core for PXI-8102 1 GB (1 x 1 GB DIMM) 800 MHz DDR2 RAM standard, 4 GB (1 x 4 GB DIMMs)
More informationCisco MCS 7825-I1 Unified CallManager Appliance
Data Sheet Cisco MCS 7825-I1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND
More informationFeatures. RoHS COMPLIANT 2002/95/EC
PCIE-1730 32-ch TTL and 32-ch Isolated Digital I/O PCI Express Card 32-ch isolated DI/O (16-ch digital input, 16-ch digital output) 32-ch TTL DI/O (16-ch digital input,16-ch digital output) High output
More informationPersonal Daqs USB Data Acquisition Modules Models /55 & /56
USB Data Acquisition Modules Models /55 & /56 Features Multi-function data acquisition modules attach to PCs via Universal Serial Bus (USB) Ultra low-power design requires no external power or batteries
More informationOpen Platform for Developing and Testing Smart Grid Automation Systems. Igor Alvarado National Instruments Corp.
Open Platform for Developing and Testing Smart Grid Automation Systems Igor Alvarado National Instruments Corp. Panel 1: State of the Art: Modeling, Simulation, Testing and Calibration Facilities April
More informationCLAD Exam Preparation Guide using LabVIEW NXG
CLAD Exam Preparation Guide using LabVIEW NXG This prep guide prepares you to take the CLAD exam using LabVIEW NXG if you registered to take the exam on or after July 31, 2017. If you want to take the
More informationEMX-2401 DATA SHEET FEATURES 3U EMBEDDED CONTROLLER FOR PXI EXPRESS SYSTEMS. Powerful computing power with Intel Core i5-520e 2.
DATA SHEET EMX-2401 3U EMBEDDED CONTROLLER FOR PXI EXPRESS SYSTEMS FEATURES Powerful computing power with Intel Core i5-520e 2.4 GHz processor Dual Channel DDR3 SODIMM up to 8 GB 1066 MHz Maximum System
More information