The QLogic 8200 Series is the Adapter of Choice for Converged Data Centers

Size: px
Start display at page:

Download "The QLogic 8200 Series is the Adapter of Choice for Converged Data Centers"

Transcription

1 The QLogic 82 Series is the Adapter of QLogic 1GbE Converged Network Adapter Outperforms Alternatives in Dell 12G Servers QLogic 82 Series Converged Network Adapter outperforms the alternative adapter in throughput per CPU utilization for both networking and converged traffic while using only a fraction of the host resources, leaving plenty of room for data center servers to efficiently scale applications and virtual servers. KEY FINDINGS The QLogic 82 Series 1Gb Converged Network Adapter offers greater efficiency in scaling (including maximum throughput and overall CPU efficiency) compared to alternative Converged Network Adapters. The QLogic adapter better supports the additional demands of a converged, virtualized data center. Our results demonstrate the following: Bandwidth: The QLogic adapter can achieve near line rate (38Gbps) of bidirectional throughput with low (a little more than 1 percent) CPU utilization. Networking : The QLogic adapter offers up to 49 percent higher networking throughput efficiency while requiring up to 31 percent less CPU resources compared to the alternative adapter. Teaming: In a link aggregation configuration, QLogic s adapter delivers up to 27 percent or 3.9Gbps higher throughput as workloads increase, as well as up to 49 percent higher throughput efficiency (Mbps/CPU utilization) compared to the alternative adapter. FCoE : For real-world applications (typically 4/8KB block sizes) QLogic s adapters outperform the alternative adapter by up to 53.9 percent. EXECUTIVE SUMMARY Leading the data center charge in I/O consolidation is Fibre Channel over Ethernet (FCoE). FCoE promises to unify data and storage traffic onto a single wire. As FCoE helps to enable data center consolidation, CPU efficiency related to I/O is emerging as a key factor in maximizing network consolidation. This is true for a couple of reasons: Consolidation creates denser server environments, which in turn drive higher throughput requirements for business-critical applications. By lowering CPU requirements to process I/O, virtualization ratios can be maximized to consolidate applications on fewer servers, thereby accomplishing low total cost of ownership (TCO). High throughput with low CPU utilization is the key to scaling within next-generation data centers. A Converged Network Adapter can easily accomplish this by offloading I/O processing for IP, iscsi, and FCoE from the host CPU. At the time this paper was first published, the QLogic 82 Series Converged Network Adapter was the only Converged Network Adapter to offload Fibre Channel over Ethernet (FCoE), iscsi, and IP (Ethernet) traffic concurrently. SN Rev. C 2/17 1

2 The QLogic 82 Series is the Adapter of TEST CONFIGURATIONS AND PROCEDURES The testing discussed in this paper analyzes and compares both QLogic and competitive Converged Network Adapters in a representative selection across Ethernet and FCoE simulations of real-world workloads. Ethernet Configuration The industry s leading IxChariot test tool was used to simulate real-world applications and to evaluate each adapter s performance under realistic load conditions. IxChariot was used due to its ability to accurately assess the performance characteristics of an adapter running within a data center network. Chariot measurements were taken to determine the total throughput (Mbps) across increasing workloads (threads) and the percentage of CPU required. Throughput was then averaged across each thread count to estimate the CPU efficiency (Mbps/CPU). CPU efficiency provides an excellent estimate of the overhead imposed on the processor by running the significant networking traffic and handling network interrupts. During these tests, the workloads were increased by adding threads to reach a maximum of 2. As a result, these tests provide significant insight into each adapter s potential networking performance and remaining headroom to efficiently scale. Appendix A provides additional information regarding the test configuration (such as servers and driver versions). The testing demonstrated the QLogic adapter s performance advantages, which provide significantly greater CPU efficiency and an enhanced ability to scale in a virtualized environment compared to the alternative adapter. Ethernet Test Procedure 1. A QLogic 1Gb Ethernet dual-port PCIe 2. to Converged Network Adapter () was installed on the test server using the latest released driver. 2. IxChariot was set up with two End Point (EP) agents installed as remote agents, and an Ethernet Switch was installed between them. Each remote agent was set up to create and measure network traffic. 3. An IxChariot console was then attached to each EP to indicate what to transmit, when to transmit, and what data to collect. One End Point was designated as a client and the other as a server. Dual-port NIC Performance Testing each port on the server was configured and connected to two separate client servers. Teaming/failover Testing the dual-port QLogic adapter within the server was then configured for teaming with port as the active primary port and port1 as the secondary failover port. 4. The type of data transmission to model was selected. The type chosen was the default high performance throughput script. 5. The testing was run for standard MTU size with multiple threads. The NIC dual-port bi-directional scenario utilized both ports simultaneously to measure the total throughput capabilities and the CPU efficiency of a dual-port adapter. The failover scenario testing used bi-directional traffic across one active port while the second port was in active standby mode. 6. To simulate the failover, the cable was pulled from port on the server during data transmission while the test script was running. 7. These steps were repeated for the other Converged Network Adapter. FCoE Configuration The IOmeter I/O test tool was used to benchmark the QLogic 82 Series 1Gb Converged Network Adapter versus the alternative. The tool was chosen because of its ability to simulate real-world applications and to evaluate adapter and system performance under realistic storage workload conditions. The test accurately assesses the performance characteristics of an adapter running on a converged network. IOmeter measurements were taken for the total amount of transactions (IOPS), the total throughput (MBps) across real-world applications (block sizes of 4 and 8KB), and the percentage of CPU required to drive overall transactions. IOPS were then normalized by the CPU usage over the testing period to calculate the CPU efficiency (IOPS/CPU). A higher number indicates more efficient use of CPU resources for I/O. Appendix A provides additional information regarding the test configuration (such as servers and driver versions). Figure 1. Networking Test Configuration SN Rev. C 2/17 2

3 The QLogic 82 Series is the Adapter of FCoE Test Procedure 1. A QLogic 1Gb Ethernet dual-port PCIe 2. to Converged Network Adapter () was installed on the test server using the latest released driver. 2. The adapter was then connected to a Cisco Nexus 52 switch and then to two RamSans configured with a total of eight LUNs. 3. The IOmeter was used to test for FCoE workload scalability. It was configured at a queue depth of 32 with a total of 16 workers. 4. To help simulate real-world environments, test data were run for standard storage application block sizes of 4 and 8 for sequential read (Seq RD), sequential write (Seq WR), and sequential read/write (Seq WR). 5. These steps were then repeated for the alternative Converged Network Adapter. The test results demonstrate the superiority of the QLogic offload engine to relieve CPUs of protocol processing tasks so that servers can remain highly scalable while providing high-performance data and storage applications the I/O bandwidth they require across virtualized networks. Ethernet Test Results The test results demonstrated that the QLogic 82 Series Adapters scaled more efficiently in an enterprise data center with real-world application workloads compared to the alternative Converged Network Adapters. For fully utilized NIC performance testing, dual-port bi-directional testing configuration ran traffic at full line rate across both adapter ports simultaneously. This was true for a teaming configuration simulating a high-availability environment with failover activated in a dual-port configuration with bi-directional traffic running at full line-rate speeds, and through increasing workloads. Maximum Bandwidth with Low CPU The QLogic 82 Series Converged Network Adapter is capable of delivering near line-rate performance from a dual-port, 1Gb adapter over a PCI Express Gen2 bus. This equates to more than 36Gbps (given a marginal loss for bus latencies and encoding overhead). When compared to alternatives, QLogic s dual-port 82 Series Adapter delivers more than 36Gbps of aggregate bidirectional throughput when sending 15B frames and uses approximately 14 percent of the host server s CPU (Figure 3). The total bandwidth and CPU utilization were captured for both adapters. The results show that QLogic has the advantage over the alternative; QLogic improves server performance by providing line-rate network bandwidth while limiting CPU overhead % CPU 22% CPU Mbps 2 15 Figure 2. FCoE Test Configuration TEST RESULTS The test procedures were specifically designed to test data and storage I/O running over a converged 1Gb Ethernet network. In each test case, specific attention was given to the CPU utilization in relation to the I/O performance. These steps were taken to create an environment in which an enterprise-class Converged Network Adapter must perform; for example, transferring large amounts of data for an application with a high bandwidth demand while the CPU of the servers is being highly taxed by enterprise applications and virtual machines (VMs). 1 5 Figure 3. Dual-port Bi-directional Throughput and CPU SN Rev. C 2/17 3

4 The QLogic 82 Series is the Adapter of NIC AND TEAMING PERFORMANCE NIC Dual-port Bi-directional Case First, the overall Ethernet performance of the adapters were evaluated. To do this, a real-world test scenario was created using both ports of a dualport adapter. Bi-directional data was sent through each simultaneously. The testing verified that the QLogic adapter again holds a significant advantage in CPU efficiency, averaging more than a 31 percent advantage over the alternative between 2 2 threads (Figure 4). CPU % Figure 4. CPU Utilization Again, this becomes even more evident when looking at the throughput normalized by the percentage of the CPU that is required to drive the transactions. To calculate this number, the total throughput transmitted and received by both ports was divided by the average CPU percentage required to drive the I/O. The results show the QLogic adapter s advantage over the alternative adapter to deliver high throughput rates while minimizing CPU utilization (Figure 5). The QLogic adapter holds an average efficiency advantage of 49 percent over the alternative adapter. CPU effectiveness in regards to I/O will emerge as a key factor in maximizing data center efficiencies as well as consolidation efforts. This stands true for a couple of reasons. First, consolidation creates denser server environments, which in turn drive higher throughput requirements for business-critical applications. Second, by lowering CPU requirements to process I/O, virtualization ratios can be maximized to fully optimize servers. The QLogic 82 Series Converged Network Adapters provide the scalability advantages that will be required by future enterprise-class data centers. NIC Teaming Failover Case To test the ability of an adapter to meet the high availability and high throughput requirements of an enterprise data center, measurements were taken for total throughput of all data sent and received across an increasing workload. During this time, a failover state was replicated to demonstrate a high-availability environment. This data was then averaged across the CPU usage consumed over the testing period to determine the adapter s efficiency. Average throughput by overall CPU usage provides an excellent estimate of the overhead imposed by the adapter while running the benchmark and handling network interrupts. In addition, it serves to demonstrate each adapter s networking performance capabilities and potential to efficiently scale. During the testing, the QLogic 82 Series Adapter outperformed the alternative adapter by an average of up to 27 percent or 3.9Gbps over increasing workloads from 4 2 threads with bi-directional send and receive I/O (Figure 6) MBps Mbps/CPU % Figure 6. Bi-directional I/O Throughput with Increasing s Figure 5. Dual-port Bi-directional CPU Efficiencies SN Rev. C 2/17 4

5 The QLogic 82 Series is the Adapter of In the bi-directional NIC failover test, the QLogic adapter required substantially less CPU resources than the alternative adapter to drive more data. In fact, the QLogic adapter used on average a little more than five percent of the CPU 18 percent less than the amount the alternative adapter required (Figure 7). CPU % Figure 7. CPU Usage in a Teamed I/O Environment Due to their low overhead, QLogic adapters leave the host server with plenty of CPU resources for the server to efficiently scale. This is imperative in next-generation data centers that run converged networks and/or VMs. This becomes even more evident when considering the throughput normalized by the percentage of the CPU that is required to drive the I/O (Figure 8). FCoE Test Results To evaluate FCoE storage I/O performance, QLogic created a real-world test scenario to verify an adapter s ability to deliver high throughput rates while minimizing CPU utilization. Using this standard testing philosophy, QLogic tested our 82 Series Converged Network Adapter against a leading alternative Converged Network Adapter within a Windows Server 28 environment, with a focus on comparing IOPS relative to CPU utilization. Measurements were done for throughput (MBps) across real-world block sizes of 4 and 8KB and a comparison was performed of the percentage of CPU utilization required to drive the I/O. Test results are reported as MBps divided by the percentage of CPU utilization to obtain the CPU efficiency. A higher number indicates more efficient use of CPU resources. As shown in Figure 9, a Converged Network Adapter from each company was used to obtain performance results for sequential read, sequential write, and sequential read/write I/O operations. Block sizes of 4 and 8KB, which are typical of Exchange and database workloads, were measured, and the results show that the QLogic 82 Series Adapter significantly outperforms the alternative adapter. The data confirms that with sequential 8KB read/write block sizes, which simulate application workloads for Oracle and Microsoft Exchange 27, the QLogic 82 Converged Network Adapter holds a 54 percent CPU efficiency advantage over the alternative CNA MBps/CPU % IOPs/CPU s Figure 8. Bi-directional I/O CPU Efficiency with Increasing s 4KB 8KB 4KB 8KB 8KB Seq RD Seq WR Seq RW Block Size Figure 9. Dual-port FCoE Throughput Divided by CPU Percentage CPU Percentage KB 8KB 4KB 8KB Seq RD Seq RW Block Size Figure 1. FCoE CPU Utilization SN Rev. C 2/17 5

6 The QLogic 82 Series is the Adapter of SUMMARY AND CONCLUSION Consolidation onto a single unified network Fibre Channel over Ethernet reduces physical complexity, lowers material costs, and simplifies operations. Ultimately, though, the most important benefit of a unified network is the gained efficiency in resource utilization. This is true as networks are consolidated onto a single protocol supporting all enterprise requirements, along with backward compatibility of each across existing hardware and management applications. However, if the wrong Converged Network Adapter is chosen to standardize on, efficiency for high throughput demands of applications, density of virtual servers, and overall consolidation efforts will fall short. As leading CIOs and data center managers strive to achieve maximum efficiency through resource utilization, QLogic delivers high-performance I/O solutions that minimize CPU resources, allowing efficient scaling of the entire data center. This is especially important for virtualized environments that support increasingly powerful applications as well as growing amounts of data. QLogic furnishes key infrastructure components with the greatest offload capabilities to provide high-performance data and storage applications the I/O bandwidth they require and to ensure that server resources are available when needed. Data center fabrics based on QLogic technology will increase enterprise IT efficiencies derived from the ability to expand the number of simultaneous applications or virtualized operating systems that can be run on a given platform. APPENDIX A Nehalem-based Server Operating System QLogic Converged Network Adapter -SR IxChariot Nehalem-based Server Operating System NIC Testing Configuration Server Configuration DL38 G6 Quad core dual 2.93Ghz 12GB RAM Windows Server 28 R2 Converged Network Adapters Driver: Network Test Tool Firmware: build 114 FCoE Testing Configuration Server Configuration Test Tool Default Chariot high-performance throughput script DL38 G6 Quad core dual 2.8Ghz 24GB RAM IOmeter QLogic Converged Network Adapter -SR Windows Server 28 R2 Converged Network Adapters Driver: Firmware: Storage Configuration RamSan 325 Switch Firmware: p6 Cisco Nexus 52 BIO version 1.2. Follow us: Share: Corporate Headquarters Cavium, Inc N. First Street San Jose, CA International Offices UK Ireland Germany France India Japan China Hong Kong Singapore Taiwan Israel 217 QLogic Corporation. QLogic Corporation is a wholly owned subsidiary of Cavium, Inc. All rights reserved worldwide. QLogic and the QLogic logo are registered trademarks of QLogic Corporation. Cisco and Cisco Nexus are trademarks, registered trademarks, and/or service marks of Cisco Systems, Inc. IxChariot is a registered trademark of Ixia. PCIe and PCI Express are registered trademarks of PCI-SIG Corporation. RamSan is a registered trademark of Texas Memory Systems. Microsoft Exchange and Windows Server are registered trademarks of Microsoft Corporation. Oracle is a registered trademark of Oracle Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. This document is provided for informational purposes only and may contain errors. QLogic reserves the right, without notice, to make changes to this document or in product design or specifications. QLogic disclaims any warranty of any kind, expressed or implied, and does not guarantee that any results or performance described in the document will be achieved by you. All statements regarding QLogic s future direction and intent are subject to change or withdrawal without notice and represent goals and objectives only. SN Rev. C 2/17 6

8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments

8Gb Fibre Channel Adapter of Choice in Microsoft Hyper-V Environments 8Gb Fibre Channel Adapter of Choice in QLogic 8Gb Adapter from Cavium Outperforms Emulex QLogic Offers Best Performance and Scalability in Hyper-V Environments Cavium s QLogic and the Emulex 8Gb Fibre

More information

QLogic 16Gb Gen 5 Fibre Channel for Database and Business Analytics

QLogic 16Gb Gen 5 Fibre Channel for Database and Business Analytics QLogic 16Gb Gen 5 Fibre Channel for Database Assessment for Database and Business Analytics Using the information from databases and business analytics helps business-line managers to understand their

More information

QLogic 10GbE High-Performance Adapters for Dell PowerEdge Servers

QLogic 10GbE High-Performance Adapters for Dell PowerEdge Servers Proven Ethernet Technology for Rack, Tower, and Blade Servers The family of QLogic 10GbE Converged Network Adapters extends Ethernet s proven value set and economics to public and private cloud-based data

More information

QLogic/Lenovo 16Gb Gen 5 Fibre Channel for Database and Business Analytics

QLogic/Lenovo 16Gb Gen 5 Fibre Channel for Database and Business Analytics QLogic/ Gen 5 Fibre Channel for Database Assessment for Database and Business Analytics Using the information from databases and business analytics helps business-line managers to understand their customer

More information

NVMe over Universal RDMA Fabrics

NVMe over Universal RDMA Fabrics NVMe over Universal RDMA Fabrics Build a Flexible Scale-Out NVMe Fabric with Concurrent RoCE and iwarp Acceleration Broad spectrum Ethernet connectivity Universal RDMA NVMe Direct End-to-end solutions

More information

QLogic 2500 Series FC HBAs Accelerate Application Performance

QLogic 2500 Series FC HBAs Accelerate Application Performance QLogic 2500 Series FC HBAs Accelerate QLogic 8Gb Fibre Channel Adapters from Cavium: Planning for Future Requirements 8Gb Performance Meets the Needs of Next-generation Data Centers EXECUTIVE SUMMARY It

More information

QLE10000 Series Adapter Provides Application Benefits Through I/O Caching

QLE10000 Series Adapter Provides Application Benefits Through I/O Caching QLE10000 Series Adapter Provides Application Benefits Through I/O Caching QLogic Caching Technology Delivers Scalable Performance to Enterprise Applications Key Findings The QLogic 10000 Series 8Gb Fibre

More information

Benefits of Offloading I/O Processing to the Adapter

Benefits of Offloading I/O Processing to the Adapter Benefits of Offloading I/O Processing to the Adapter FCoE and iscsi Protocol Offload Delivers Enterpriseclass Performance, Reliability, and Scalability Hewlett Packard Enterprise (HPE) and Cavium have

More information

Cavium FastLinQ 25GbE Intelligent Ethernet Adapters vs. Mellanox Adapters

Cavium FastLinQ 25GbE Intelligent Ethernet Adapters vs. Mellanox Adapters Cavium FastLinQ 25GbE Intelligent Ethernet Adapters vs. Mellanox Adapters Cavium FastLinQ QL45000 25GbE adapters provide maximum performance and flexible bandwidth management to optimize virtualized servers

More information

Visualize I/O Connectivity for VMware vsphere

Visualize I/O Connectivity for VMware vsphere Visualize I/O Connectivity for VMware vsphere Cavium s QLogic QConvergeConsole Plug-in for VMware vcenter simplifies and accelerates deployment and management. KEY FINDINGS The QLogic adapter portfolio

More information

Disabling the FCoE Function on HPE FlexFabric Adapters from QLogic. Products Affected. HPE FlexFabric 10Gb 2-port 534FLR-SFP B21

Disabling the FCoE Function on HPE FlexFabric Adapters from QLogic. Products Affected. HPE FlexFabric 10Gb 2-port 534FLR-SFP B21 Application Note Disabling the FCoE Function on HPE FlexFabric Adapters from QLogic Products Affected HPE Model Part Number HPE FlexFabric 10Gb 2-port 533FLR-T 700759-B21 HPE FlexFabric 10Gb 2-port 534FLR-SFP+

More information

Configuring Cavium SmartAN for HPE Ethernet 10/25GbE Adapters. Products Supported. HPE Ethernet 10/25Gb 621SFP28 Adapter B21

Configuring Cavium SmartAN for HPE Ethernet 10/25GbE Adapters. Products Supported. HPE Ethernet 10/25Gb 621SFP28 Adapter B21 Application Note Configuring Cavium SmartAN for HPE Ethernet 10/25GbE Adapters Products Supported Adapter Model Part Number HPE Ethernet 10/25Gb 621SFP28 Adapter 867328-B21 HPE Ethernet 10/25Gb 622FLR-SFP28

More information

FC-NVMe. NVMe over Fabrics. Fibre Channel the most trusted fabric can transport NVMe natively. White Paper

FC-NVMe. NVMe over Fabrics. Fibre Channel the most trusted fabric can transport NVMe natively. White Paper FC-NVMe NVMe over Fabrics Fibre Channel the most trusted fabric can transport NVMe natively BACKGROUND AND SUMMARY Ever since IBM shipped the world s first hard disk drive (HDD), the RAMAC 305 in 1956,

More information

NVMe Direct. Next-Generation Offload Technology. White Paper

NVMe Direct. Next-Generation Offload Technology. White Paper NVMe Direct Next-Generation Offload Technology The market introduction of high-speed NVMe SSDs and 25/40/50/100Gb Ethernet creates exciting new opportunities for external storage NVMe Direct enables high-performance

More information

Emulex OCe11102-N and Mellanox ConnectX-3 EN on Windows Server 2008 R2

Emulex OCe11102-N and Mellanox ConnectX-3 EN on Windows Server 2008 R2 Competitive Benchmark Emulex OCe11102-N and Mellanox ConnectX-3 EN on Windows Server 2008 R2 Performance Tests Simulating Real-World Workloads Table of contents At a Glance... 3 Introduction... 3 Performance...

More information

Emulex LPe16000B 16Gb Fibre Channel HBA Evaluation

Emulex LPe16000B 16Gb Fibre Channel HBA Evaluation Demartek Emulex LPe16000B 16Gb Fibre Channel HBA Evaluation Evaluation report prepared under contract with Emulex Executive Summary The computing industry is experiencing an increasing demand for storage

More information

Demartek September Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi. Introduction. Evaluation Environment. Evaluation Summary

Demartek September Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi. Introduction. Evaluation Environment. Evaluation Summary Intel 10GbE Adapter Performance Evaluation for FCoE and iscsi Evaluation report prepared under contract with Intel Corporation Introduction As the interest in converged networks grows, and as the vendors

More information

Network Function Virtualization Using Data Plane Developer s Kit

Network Function Virtualization Using Data Plane Developer s Kit Network Function Virtualization Using Enabling 25GbE to 100GbE Virtual Network Functions with Cavium FastLinQ Intelligent Ethernet Adapters DPDK addresses key scalability issues of NFV workloads Cavium

More information

Application Note Setting the QL41xxx Link Speed Using QCS CLI

Application Note Setting the QL41xxx Link Speed Using QCS CLI Application Note Setting the QL41xxx Link Speed Using QCS CLI 1 Products Affected 2 Prerequisites 3 Overview This application note applies to QLogic FastLinQ QL41xxx adapters from Cavium that need to have

More information

Evaluation of the Chelsio T580-CR iscsi Offload adapter

Evaluation of the Chelsio T580-CR iscsi Offload adapter October 2016 Evaluation of the Chelsio T580-CR iscsi iscsi Offload makes a difference Executive Summary As application processing demands increase and the amount of data continues to grow, getting this

More information

VM Aware Fibre Channel

VM Aware Fibre Channel White Paper White Paper VM-ID VM Aware Fibre Channel Virtual Machine Traffic Visibility for SANs StorFusion VM-ID feature on QLogic Gen6 (32G) and Enhanced Gen5 (16G) Fibre Channel KEY BENEFITS Increases

More information

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays Dell EqualLogic Best Practices Series Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell EqualLogic Storage Arrays A Dell Technical Whitepaper Jerry Daugherty Storage Infrastructure

More information

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform W h i t e p a p e r Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform How to Deploy Converged Networking with a Windows Server Platform Using Emulex OneConnect

More information

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4 W H I T E P A P E R Comparison of Storage Protocol Performance in VMware vsphere 4 Table of Contents Introduction................................................................... 3 Executive Summary............................................................

More information

Introduction to Ethernet Latency

Introduction to Ethernet Latency Introduction to Ethernet Latency An Explanation of Latency and Latency Measurement The primary difference in the various methods of latency measurement is the point in the software stack at which the latency

More information

QLogic TrueScale InfiniBand and Teraflop Simulations

QLogic TrueScale InfiniBand and Teraflop Simulations WHITE Paper QLogic TrueScale InfiniBand and Teraflop Simulations For ANSYS Mechanical v12 High Performance Interconnect for ANSYS Computer Aided Engineering Solutions Executive Summary Today s challenging

More information

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays Dell EMC Engineering December 2016 A Dell Best Practices Guide Revisions Date March 2011 Description Initial

More information

Emulex LPe16000B Gen 5 Fibre Channel HBA Feature Comparison

Emulex LPe16000B Gen 5 Fibre Channel HBA Feature Comparison Demartek Emulex LPe16000B Gen 5 Fibre Channel HBA Feature Comparison Evaluation report prepared under contract with Emulex Executive Summary Explosive growth in the complexity and amount of data of today

More information

Cisco UCS Virtual Interface Card 1225

Cisco UCS Virtual Interface Card 1225 Data Sheet Cisco UCS Virtual Interface Card 1225 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites compute, networking,

More information

Use of the Internet SCSI (iscsi) protocol

Use of the Internet SCSI (iscsi) protocol A unified networking approach to iscsi storage with Broadcom controllers By Dhiraj Sehgal, Abhijit Aswath, and Srinivas Thodati In environments based on Internet SCSI (iscsi) and 10 Gigabit Ethernet, deploying

More information

Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems

Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems NETAPP TECHNICAL REPORT Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems A Performance Comparison Study of FC, iscsi, and NFS Protocols Jack McLeod, NetApp

More information

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces

Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces Low Latency Evaluation of Fibre Channel, iscsi and SAS Host Interfaces Evaluation report prepared under contract with LSI Corporation Introduction IT professionals see Solid State Disk (SSD) products as

More information

SAN Virtuosity Fibre Channel over Ethernet

SAN Virtuosity Fibre Channel over Ethernet SAN VIRTUOSITY Series WHITE PAPER SAN Virtuosity Fibre Channel over Ethernet Subscribe to the SAN Virtuosity Series at www.sanvirtuosity.com Table of Contents Introduction...1 VMware and the Next Generation

More information

Version 1.0 October Reduce CPU Utilization by 10GbE CNA with Hardware iscsi Offload

Version 1.0 October Reduce CPU Utilization by 10GbE CNA with Hardware iscsi Offload Version 1.0 October 2012 Reduce CPU Utilization by 10GbE CNA with Hardware iscsi Offload Copyright Copyright@2004~2012, Qsan Technology, Inc. All rights reserved. No part of this document may be reproduced

More information

Comparison of Storage Protocol Performance ESX Server 3.5

Comparison of Storage Protocol Performance ESX Server 3.5 Performance Study Comparison of Storage Protocol Performance ESX Server 3.5 This study provides performance comparisons of various storage connection options available to VMware ESX Server. We used the

More information

QLogic FastLinQ QL41232HMKR

QLogic FastLinQ QL41232HMKR QLogic FastLinQ QL41232HMKR Dual-port 10/25GbE Intelligent Ethernet Adapter with Universal RDMA for Dell PowerEdge Blade Servers Industry s most advanced 25GbE adapter delivers the best price and performance

More information

Cisco UCS Virtual Interface Card 1227

Cisco UCS Virtual Interface Card 1227 Data Sheet Cisco UCS Virtual Interface Card 1227 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites computing,

More information

Emulex Universal Multichannel

Emulex Universal Multichannel Emulex Universal Multichannel Reference Manual Versions 11.2 UMC-OCA-RM112 Emulex Universal Multichannel Reference Manual Corporate Headquarters San Jose, CA Website www.broadcom.com Broadcom, the pulse

More information

QLogic 2700 Series. Gen 6 FC (32GFC) Fibre Channel Adapters. Data Sheet OVERVIEW

QLogic 2700 Series. Gen 6 FC (32GFC) Fibre Channel Adapters. Data Sheet OVERVIEW QLogic 2700 Series Gen 6 FC (32GFC) Fibre Channel Adapters Industry s first Gen 6 FC HBA available in single, dual, and quad-port versions Up to four ports of Gen 6 FC deliver 25,600MBps aggregate throughput

More information

ARISTA: Improving Application Performance While Reducing Complexity

ARISTA: Improving Application Performance While Reducing Complexity ARISTA: Improving Application Performance While Reducing Complexity October 2008 1.0 Problem Statement #1... 1 1.1 Problem Statement #2... 1 1.2 Previous Options: More Servers and I/O Adapters... 1 1.3

More information

Optimize New Intel Xeon E based Ser vers with Emulex OneConnect and OneCommand Manager

Optimize New Intel Xeon E based Ser vers with Emulex OneConnect and OneCommand Manager W h i t e p a p e r Optimize New Intel Xeon E5-2600-based Ser vers with Emulex OneConnect and OneCommand Manager Emulex products complement Intel Xeon E5-2600 processor capabilities for virtualization,

More information

Gen 6 Fibre Channel Evaluation of Products from Emulex and Brocade

Gen 6 Fibre Channel Evaluation of Products from Emulex and Brocade Gen 6 Fibre Channel Evaluation of Products from Emulex and Brocade Gen 6 Fibre Channel provides new speeds and features for enterprise datacenters. Executive Summary Large enterprises choose Fibre Channel

More information

HP BladeSystem c-class Ethernet network adapters

HP BladeSystem c-class Ethernet network adapters HP BladeSystem c-class Ethernet network adapters Family data sheet HP NC552m 10 Gb Dual Port Flex-10 Ethernet Adapter HP NC551m Dual Port FlexFabric 10 Gb Converged Network Adapter HP NC550m 10 Gb Dual

More information

A Principled Technologies deployment guide commissioned by QLogic Corporation

A Principled Technologies deployment guide commissioned by QLogic Corporation A Principled Technologies deployment guide commissioned by QLogic Corporation Table of contents Executive summary... 2 Introduction... 2 QLogic QConvergeConsole... 3 Overview of the procedure... 4 Initial

More information

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage

Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage Microsoft SQL Server in a VMware Environment on Dell PowerEdge R810 Servers and Dell EqualLogic Storage A Dell Technical White Paper Dell Database Engineering Solutions Anthony Fernandez April 2010 THIS

More information

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager Reference Architecture Copyright 2010 EMC Corporation. All rights reserved.

More information

Microsoft Office SharePoint Server 2007

Microsoft Office SharePoint Server 2007 Microsoft Office SharePoint Server 2007 Enabled by EMC Celerra Unified Storage and Microsoft Hyper-V Reference Architecture Copyright 2010 EMC Corporation. All rights reserved. Published May, 2010 EMC

More information

Cisco Nexus 5000 and Emulex LP21000

Cisco Nexus 5000 and Emulex LP21000 Cisco Nexus 5000 and Emulex LP21000 A Fibre Channel over Ethernet Technology and Solutions Overview Prepared by: Cisco Systems, Inc. and Emulex Introduction Data center managers today are being challenged

More information

QLogic FastLinQ QL45462HLCU 40GbE Converged Network Adapter

QLogic FastLinQ QL45462HLCU 40GbE Converged Network Adapter QLogic FastLinQ QL45462HLCU 40GbE Converged Network Adapter Fully featured 40GbE adapter delivers the best price per performance ratio versus 10GbE Increase VM density and accelerate multitenant networks

More information

Microsoft SQL Server 2012 Fast Track Reference Configuration Using PowerEdge R720 and EqualLogic PS6110XV Arrays

Microsoft SQL Server 2012 Fast Track Reference Configuration Using PowerEdge R720 and EqualLogic PS6110XV Arrays Microsoft SQL Server 2012 Fast Track Reference Configuration Using PowerEdge R720 and EqualLogic PS6110XV Arrays This whitepaper describes Dell Microsoft SQL Server Fast Track reference architecture configurations

More information

Evaluation of Chelsio Terminator 6 (T6) Unified Wire Adapter iscsi Offload

Evaluation of Chelsio Terminator 6 (T6) Unified Wire Adapter iscsi Offload November 2017 Evaluation of Chelsio Terminator 6 (T6) Unified Wire Adapter iscsi Offload Initiator and target iscsi offload improve performance and reduce processor utilization. Executive Summary The Chelsio

More information

Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches

Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches . White Paper Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches Introduction Best practices for I/O connectivity in today s data centers configure each server with redundant connections

More information

Evaluation of Multi-protocol Storage Latency in a Multi-switch Environment

Evaluation of Multi-protocol Storage Latency in a Multi-switch Environment Evaluation of Multi-protocol Storage in a Multi-switch Environment Evaluation report prepared under contract with Cisco Systems, Inc. Executive Summary In today s complex storage networking environments

More information

HP Embeds Converged Network Adapters

HP Embeds Converged Network Adapters HP Embeds Converged Network Adapters By Frank Berry January, 2011 In the movie Field of Dreams, Ray Kinsella (Kevin Costner) hears a voice whisper, "If you build it, they will come, and sees a vision of

More information

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp Agenda The Landscape has Changed New Customer Requirements The Market has Begun to Move Comparing Performance Results Storage

More information

QLogic QLE2694 and QLE2694L

QLogic QLE2694 and QLE2694L QLogic QLE2694 and QLE2694L Quad-port Enhanced Gen 5 FC (16GFC) Fibre Channel Adapters Industry s first native quad-port solution supporting 16GFC technology Four ports of 16GFC Enhanced Gen 5 FC deliver

More information

Extremely Fast Distributed Storage for Cloud Service Providers

Extremely Fast Distributed Storage for Cloud Service Providers Solution brief Intel Storage Builders StorPool Storage Intel SSD DC S3510 Series Intel Xeon Processor E3 and E5 Families Intel Ethernet Converged Network Adapter X710 Family Extremely Fast Distributed

More information

QLogic BR-815 and BR-825 Fibre Channel Adapters

QLogic BR-815 and BR-825 Fibre Channel Adapters QLogic BR-815 and BR-825 Fibre Channel Adapters OVERVIEW Provides high-performance, line-rate 8Gbps Fibre Channel for enterprise-class, reliable SAN connectivity Maximizes bus throughput with a Fibre Channel-to-PCIe

More information

PCI Express x8 Single Port SFP+ 10 Gigabit Server Adapter (Intel 82599ES Based) Single-Port 10 Gigabit SFP+ Ethernet Server Adapters Provide Ultimate

PCI Express x8 Single Port SFP+ 10 Gigabit Server Adapter (Intel 82599ES Based) Single-Port 10 Gigabit SFP+ Ethernet Server Adapters Provide Ultimate NIC-PCIE-1SFP+-PLU PCI Express x8 Single Port SFP+ 10 Gigabit Server Adapter (Intel 82599ES Based) Single-Port 10 Gigabit SFP+ Ethernet Server Adapters Provide Ultimate Flexibility and Scalability in Virtual

More information

FastLinQ QL41162HLRJ. 8th Generation 10Gb Converged Network Adapter with iscsi, FCoE, and Universal RDMA. Product Brief OVERVIEW

FastLinQ QL41162HLRJ. 8th Generation 10Gb Converged Network Adapter with iscsi, FCoE, and Universal RDMA. Product Brief OVERVIEW FastLinQ QL41162HLRJ 8th Generation 10Gb Converged Network Adapter with iscsi, FCoE, and Universal RDMA Delivers full line-rate 10GbE performance across both ports Universal RDMA Delivers choice and flexibility

More information

Emulex -branded Fibre Channel HBA Product Line

Emulex -branded Fibre Channel HBA Product Line Emulex -branded Fibre Channel HBA Product Line Emulex-branded Fibre Channel (FC) Host Bus Adapters (HBAs) by Broadcom are designed to address the demanding performance, reliability and management requirements

More information

The Missing Piece of Virtualization. I/O Virtualization on 10 Gb Ethernet For Virtualized Data Centers

The Missing Piece of Virtualization. I/O Virtualization on 10 Gb Ethernet For Virtualized Data Centers The Missing Piece of Virtualization I/O Virtualization on 10 Gb Ethernet For Virtualized Data Centers Agenda 10 GbE Adapters Built for Virtualization I/O Throughput: Virtual & Non-Virtual Servers Case

More information

USING ISCSI AND VERITAS BACKUP EXEC 9.0 FOR WINDOWS SERVERS BENEFITS AND TEST CONFIGURATION

USING ISCSI AND VERITAS BACKUP EXEC 9.0 FOR WINDOWS SERVERS BENEFITS AND TEST CONFIGURATION WHITE PAPER Maximize Storage Networks with iscsi USING ISCSI AND VERITAS BACKUP EXEC 9.0 FOR WINDOWS SERVERS BENEFITS AND TEST CONFIGURATION For use with Windows 2000 VERITAS Software Corporation 03/05/2003

More information

All Roads Lead to Convergence

All Roads Lead to Convergence All Roads Lead to Convergence Greg Scherer VP, Server and Storage Strategy gscherer@broadcom.com Broadcom Corporation 2 Agenda The Trend Toward Convergence over Ethernet Reasons for Storage and Networking

More information

Surveillance Dell EMC Storage with Bosch Video Recording Manager

Surveillance Dell EMC Storage with Bosch Video Recording Manager Surveillance Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide H13970 REV 2.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published December

More information

Reference Architectures for designing and deploying Microsoft SQL Server Databases in Active System800 Platform

Reference Architectures for designing and deploying Microsoft SQL Server Databases in Active System800 Platform Reference Architectures for designing and deploying Microsoft SQL Server Databases in Active System800 Platform Discuss database workload classification for designing and deploying SQL server databases

More information

Lossless 10 Gigabit Ethernet: The Unifying Infrastructure for SAN and LAN Consolidation

Lossless 10 Gigabit Ethernet: The Unifying Infrastructure for SAN and LAN Consolidation . White Paper Lossless 10 Gigabit Ethernet: The Unifying Infrastructure for SAN and LAN Consolidation Introduction As organizations increasingly rely on IT to help enable, and even change, their business

More information

EMC Integrated Infrastructure for VMware. Business Continuity

EMC Integrated Infrastructure for VMware. Business Continuity EMC Integrated Infrastructure for VMware Business Continuity Enabled by EMC Celerra and VMware vcenter Site Recovery Manager Reference Architecture Copyright 2009 EMC Corporation. All rights reserved.

More information

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND FIBRE CHANNEL INFRASTRUCTURE Design Guide APRIL 0 The information in this publication is provided as is. Dell Inc. makes no representations or warranties

More information

16GFC Sets The Pace For Storage Networks

16GFC Sets The Pace For Storage Networks 16GFC Sets The Pace For Storage Networks Scott Kipp Brocade Mark Jones Emulex August 30 th, 2011 To be presented to the Block Storage Track at 1:30 on Monday September 19th 1 Overview What is 16GFC? What

More information

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Best practices Roland Mueller IBM Systems and Technology Group ISV Enablement April 2012 Copyright IBM Corporation, 2012

More information

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers By Todd Muirhead Dell Enterprise Technology Center Dell Enterprise Technology Center dell.com/techcenter

More information

Dell and Emulex: A lossless 10Gb Ethernet iscsi SAN for VMware vsphere 5

Dell and Emulex: A lossless 10Gb Ethernet iscsi SAN for VMware vsphere 5 Solution Guide Dell and Emulex: A lossless 10Gb Ethernet iscsi SAN for VMware vsphere 5 iscsi over Data Center Bridging (DCB) solution Table of contents Executive summary... 3 iscsi over DCB... 3 How best

More information

Active System Manager Release 8.2 Compatibility Matrix

Active System Manager Release 8.2 Compatibility Matrix Active System Manager Release 8.2 Compatibility Matrix Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Dell EMC SAP HANA Appliance Backup and Restore Performance with Dell EMC Data Domain

Dell EMC SAP HANA Appliance Backup and Restore Performance with Dell EMC Data Domain Dell EMC SAP HANA Appliance Backup and Restore Performance with Dell EMC Data Domain Performance testing results using Dell EMC Data Domain DD6300 and Data Domain Boost for Enterprise Applications July

More information

QuickSpecs. HP Z 10GbE Dual Port Module. Models

QuickSpecs. HP Z 10GbE Dual Port Module. Models Overview Models Part Number: 1Ql49AA Introduction The is a 10GBASE-T adapter utilizing the Intel X722 MAC and X557-AT2 PHY pairing to deliver full line-rate performance, utilizing CAT 6A UTP cabling (or

More information

10Gb iscsi Initiators

10Gb iscsi Initiators 10Gb iscsi Initiators t June 2009 1 iscsi 10Gb Broadcom HBA vs. 10Gb Intel Software Initiator with I/OAT enabled 2 iscsi 10Gb Broadcom HBA vs. 10Gb Intel Software Initiator with I/OAT enabled Key findings

More information

2014 LENOVO INTERNAL. ALL RIGHTS RESERVED.

2014 LENOVO INTERNAL. ALL RIGHTS RESERVED. 2014 LENOVO INTERNAL. ALL RIGHTS RESERVED. Connectivity Categories and Selection Considerations NIC HBA CNA Primary Purpose Basic Ethernet Connectivity Connection to SAN/DAS Converged Network and SAN connectivity

More information

EMC Business Continuity for Microsoft Applications

EMC Business Continuity for Microsoft Applications EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All

More information

FCoE at 40Gbps with FC-BB-6

FCoE at 40Gbps with FC-BB-6 FCoE at 40Gbps with FC-BB-6 Line Rate Throughput and 2M+ IOPS over Terminator 5 Executive Summary This paper presents FCoE performance results for Chelsio s latest Terminator 5 (T5) ASIC running at 40Gbps.

More information

SAS Technical Update Connectivity Roadmap and MultiLink SAS Initiative Jay Neer Molex Corporation Marty Czekalski Seagate Technology LLC

SAS Technical Update Connectivity Roadmap and MultiLink SAS Initiative Jay Neer Molex Corporation Marty Czekalski Seagate Technology LLC SAS Technical Update Connectivity Roadmap and MultiLink SAS Initiative Jay Neer Molex Corporation Marty Czekalski Seagate Technology LLC SAS Connectivity Roadmap Background Connectivity Objectives Converged

More information

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE

DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE DELL EMC READY BUNDLE FOR VIRTUALIZATION WITH VMWARE AND ISCSI INFRASTRUCTURE Design Guide APRIL 2017 1 The information in this publication is provided as is. Dell Inc. makes no representations or warranties

More information

Accelerate Applications Using EqualLogic Arrays with directcache

Accelerate Applications Using EqualLogic Arrays with directcache Accelerate Applications Using EqualLogic Arrays with directcache Abstract This paper demonstrates how combining Fusion iomemory products with directcache software in host servers significantly improves

More information

Reference Architecture

Reference Architecture EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 in VMware ESX Server EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com

More information

Virtuozzo Hyperconverged Platform Uses Intel Optane SSDs to Accelerate Performance for Containers and VMs

Virtuozzo Hyperconverged Platform Uses Intel Optane SSDs to Accelerate Performance for Containers and VMs Solution brief Software-Defined Data Center (SDDC) Hyperconverged Platforms Virtuozzo Hyperconverged Platform Uses Intel Optane SSDs to Accelerate Performance for Containers and VMs Virtuozzo benchmark

More information

VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD

VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD VIRTUALIZING SERVER CONNECTIVITY IN THE CLOUD Truls Myklebust Director, Product Management Brocade Communications 2011 Brocade Communciations - All Rights Reserved 13 October 2011 THE ENTERPRISE IS GOING

More information

HP SAS benchmark performance tests

HP SAS benchmark performance tests HP SAS benchmark performance tests technology brief Abstract... 2 Introduction... 2 Test hardware... 2 HP ProLiant DL585 server... 2 HP ProLiant DL380 G4 and G4 SAS servers... 3 HP Smart Array P600 SAS

More information

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE White Paper EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE EMC XtremSF, EMC XtremCache, EMC Symmetrix VMAX and Symmetrix VMAX 10K, XtremSF and XtremCache dramatically improve Oracle performance Symmetrix

More information

DATA PROTECTION IN A ROBO ENVIRONMENT

DATA PROTECTION IN A ROBO ENVIRONMENT Reference Architecture DATA PROTECTION IN A ROBO ENVIRONMENT EMC VNX Series EMC VNXe Series EMC Solutions Group April 2012 Copyright 2012 EMC Corporation. All Rights Reserved. EMC believes the information

More information

HP BladeSystem c-class Ethernet network adaptors

HP BladeSystem c-class Ethernet network adaptors HP BladeSystem c-class Ethernet network adaptors Family data sheet NC325m Quad-port Gigabit NC326m Dual-port Gigabit NC360m Dual-port Gigabit NC364m Quad-port Gigabit NC382m Dual-port Multifunction Gigabit

More information

Best Practices for Deployments using DCB and RoCE

Best Practices for Deployments using DCB and RoCE Best Practices for Deployments using DCB and RoCE Contents Introduction... Converged Networks... RoCE... RoCE and iwarp Comparison... RoCE Benefits for the Data Center... RoCE Evaluation Design... RoCE

More information

Technology Insight Series

Technology Insight Series Data-Center iscsi Building next generation storage networks Russ Fellows March 8, 2010 Technology Insight Series Evaluator Group Copyright 2010 Evaluator Group, Inc. All rights reserved Data Center iscsi

More information

HP Converged Network Switches and Adapters. HP StorageWorks 2408 Converged Network Switch

HP Converged Network Switches and Adapters. HP StorageWorks 2408 Converged Network Switch HP Converged Network Switches and Adapters Family Data sheet Realise the advantages of Converged Infrastructure with HP Converged Network Switches and Adapters Data centres are increasingly being filled

More information

Broadcom Adapters for Dell PowerEdge 12G Servers

Broadcom Adapters for Dell PowerEdge 12G Servers White Paper Broadcom Adapters for Dell PowerEdge 12G Servers The Dell PowerEdge 12G family of rack, tower, and blade servers offer a broad range of storage and networking options designed to address the

More information

Comparing UFS and NVMe Storage Stack and System-Level Performance in Embedded Systems

Comparing UFS and NVMe Storage Stack and System-Level Performance in Embedded Systems Comparing UFS and NVMe Storage Stack and System-Level Performance in Embedded Systems Bean Huo, Blair Pan, Peter Pan, Zoltan Szubbocsev Micron Technology Introduction Embedded storage systems have experienced

More information

Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage

Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage Identifying Performance Bottlenecks with Real- World Applications and Flash-Based Storage TechTarget Dennis Martin 1 Agenda About Demartek Enterprise Data Center Environments Storage Performance Metrics

More information

Deploy a Next-Generation Messaging Platform with Microsoft Exchange Server 2010 on Cisco Unified Computing System Powered by Intel Xeon Processors

Deploy a Next-Generation Messaging Platform with Microsoft Exchange Server 2010 on Cisco Unified Computing System Powered by Intel Xeon Processors Deploy a Next-Generation Messaging Platform with Microsoft Exchange Server 2010 on Cisco Unified Computing System Solution Brief May 2011 Highlights Next-Generation Messaging System with Intel Xeon processors

More information

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper

SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper Dell EqualLogic Best Practices Series SAN Design Best Practices for the Dell PowerEdge M1000e Blade Enclosure and EqualLogic PS Series Storage (1GbE) A Dell Technical Whitepaper Storage Infrastructure

More information

TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage

TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage Performance Study of Microsoft SQL Server 2016 Dell Engineering February 2017 Table of contents

More information

An Oracle White Paper December Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration

An Oracle White Paper December Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration An Oracle White Paper December 2010 Accelerating Deployment of Virtualized Infrastructures with the Oracle VM Blade Cluster Reference Configuration Introduction...1 Overview of the Oracle VM Blade Cluster

More information