1 UNIFIED HYBRID STORAGE Nexsan UNITY Hardware Reference Guide Firmware Version: UNITY1.3 Nexsan 900 E. Campbell, CA p

2 Copyright Nexsan, Inc.. All Rights Reserved. Trademarks Nexsan is a trademark or registered trademark of Nexsan, Inc.. The Nexsan logo is a registered trademark of Nexsan, Inc.. All other trademarks and registered trademarks are the property of their respective owners. Patents This product is protected by one or more of the following patents, and other pending patent applications worldwide: United States patents US8,191,841, US8,120,922; United Kingdom patents GB B, GB B, GB B, GB B, GB B Regulatory Compliance United States Statement for FCC: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Electromagnetic Emissions: FCC Class A, EN Class A, EN /-3-3, CISPR 22 Class A, ICES-003 Electromagnetic Immunity: EN 55024/CISPR 24, (EN , EN , EN , EN , EN , EN , EN ) Safety: CSA/EN/IEC/UL Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) RoHS: RoHS2 (Global), RoHS (China) Other international regulatory compliance: KCC (South Korea), SABS/NCRS (South Africa), C-Tick/RCM (Australia, New Zealand), VCC (Japan) California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate Material-special handling may apply. See About This Document Unauthorized use, duplication, or modification of this document in whole or in part without the written consent of Nexsan Corporation is strictly prohibited. Nexsan, Inc. reserves the right to make changes to this manual, as well as the equipment and software described in this manual, at any time without notice. This manual may contain links to web sites that were current at the time of publication, but have since been moved or become inactive. It may also contain links to sites owned and operated by third parties. Nexsan is not responsible for the content of any such third-party site.

3 Contents About this manual Audience Conventions Text Notes, Tips, Cautions, and Warnings Contacting Nexsan Related documentation Nexsan UNITY Nexsan E-Series Safety notices v v v v v vi vii vii vii viii Chapter 1: UNITY2000 hardware 1 UNITY2000C Front and rear views 3 UNITY2000C General specifications 4 UNITY2000P Front and rear views 5 UNITY2000P General specifications 6 UNITY2000 Front panel LEDs 8 Control panel LEDs 8 Drive carrier LEDs 9 Chapter 2: UNITY4000 hardware 10 UNITY4000 Front and rear views 12 UNITY4000 Front panel LEDs 13 Control panel LEDs 13 Drive carrier LEDs 14 UNITY4000 General specifications 14 Chapter 3: UNITY5000 hardware 16 UNITY5000 Front and rear views 17 UNITY5000 Front panel LEDs 18 Control panel LEDs 18 Drive carrier LEDs 19 UNITY5000 General specifications 20 Chapter 4: UNITY6000 hardware 21 UNITY6000 Hardware components 22 UNITY6000 Front and rear views 23 UNITY6000 Front panel LEDs 24 Control panel LEDs 24 Drive carrier LEDs 26 UNITY6000 Rear panel LEDs 26 UNITY6000 General specifications 28 Chapter 5: UNITY Vault Protection Module hardware 29 UNITY Vault Protection Module front view 30 Nexsan UNITY iii

4 UNITY Vault Protection Module rear view 30 UNITY Vault Protection Module front panel LEDs and LCD screen 31 Using the UNITY Vault Protection Module LCD menu 33 Modifying the UNITY Vault Protection Module settings 34 UNITY Vault Protection Module general specifications 38 Glossary 39 Index 50 Nexsan UNITY iv

5 About this manual About this manual This Hardware Reference Guide provides hardware information for the following platforms. For installation procedures, please refer to the appropriate Quick Start Guide. Nexsan UNITY2000C TM Nexsan UNITY2000P TM Nexsan UNITY4000 Nexsan UNITY5000 Nexsan UNITY6000 This guide describes how to set up multipathing for Linux and Windows host systems. Audience This guide has been prepared for the following audience: IT system administrators Engineers Technicians Conventions Text Cross-references (both internal and to the titles of other documents), hyperlinks, URLs, and addresses are displayed in underlined blue. Text that refers to labels on the physical unit or interactive items in the graphical user interface (GUI) is in boldface. Text that is displayed in the command-line interface (CLI) or text that refers to file or directory names is in monospace. Text strings that must be entered by the user in the command-line interface or in text fields in the graphical user interface (GUI) is in monospace bold. System messages and non-interactive items in the graphical user interface (GUI) are in italic. References to Software User Guides are in italic. Notes, Tips, Cautions, and Warnings Note Notes contain important information, present alternative procedures, or call attention to certain items. Tip Tips contain handy information for end-users, such as other ways to perform an action. CAUTION: In hardware manuals, cautions alert the user to items or situations which may cause damage to the unit or result in mild injury to the user, or both. In software manuals, cautions alerts the user to situations which may cause data corruption or data loss. WARNING: Warnings alert the user to items or situations which may result in severe injury or death to the user. Nexsan UNITY v

6 Contacting Nexsan Contacting Nexsan Nexsan Headquarters 900 E Hamilton Ave, Suite 230 Campbell, CA USA Support (US): Support (Worldwide): support@nexsan.com Nexsan Canada 1405 Trans Canada Highway, Suite 300 Dorval, QC HP92V9 Canada Support (Canada): Nexsan Shipping 302 Enterprise Street, Suite A Escondido, CA USA Nexsan UK Units 33 35, Parker Centre, Mansfield Road Derby, DE21 4SZ United Kingdom Support (Europe): +44 (0) Nexsan UNITY vi

7 Related documentation Related documentation The following Imation product manuals contain related information. Nexsan UNITY Nexsan UNITY2000C TM Quick Start Guide Nexsan UNITY2000P TM Quick Start Guide Nexsan UNITY4000 Quick Start Guide Nexsan UNITY5000 Quick Start Guide Nexsan UNITY6000 Quick Start Guide Nexsan UNITY224X Quick Start Guide Nexsan UNITY2000XC TM Quick Start Guide Nexsan UNITY2000XP TM Quick Start Guide Nexsan UNITY Hardware Maintenance Guide Nexsan UNITY Software User Guide Nexsan UNITY nxadmin Command-line Interface Reference Guide Nexsan UNITY nxcmd Command-line Interface Reference Guide Nexsan UNITY Snapshots and Replication Guide Nexsan UNITY Expander Unit Reference Guide Nexsan UNITY VMware Best Practices Guide Nexsan UNITY NFS Interoperability Nexsan UNITY Networking Best Practices Guide Nexsan E-Series Nexsan E-Series E18 /E18X Quick Start Guide Nexsan E-Series E18 /E18V Installation and Maintenance Manual Nexsan E-Series E18X /E18XV Installation and Maintenance Manual Nexsan E-Series E60 /E48 /E60X /E48X Quick Start Guide Nexsan E-Series E60 /E60V /E60VT /E48 /E48V /E48VT Installation and Maintenance Manual Nexsan E-Series E60X /E60XV /E48X /E48XV Installation and Maintenance Manual Nexsan E-Series E32V Installation Guide Nexsan E-Series E32V FRU Removal and Replacement Guide Nexsan E-Series RAID Storage User Manual Nexsan E-Series Snapshots and Replication Software User Guide Nexsan UNITY vii

8 Safety notices Safety notices Always observe the following precautions to reduce the risk of injury and equipment damage: Computer components and disk drives are sensitive to static discharge. Take precautions to discharge any electrostatic charge from your person before and while handling components with your hands or any tools. Use an anti-static wrist-strap. The system only be installed in a clean, dry environment. The operating temperature is 10º to 35º C (50º to 95º F), with operating relative humidity at 20 to 95%, non-condensing. Do not install the system in an enclosed cabinet or other small area without ventilation. Ensure correct lifting methods are used when handling the unit. Special care should be taken when removing the unit from its packaging and positioning it into its required location. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs. When installing the system as a rack-mounted component, ensure that all Nexsan-supplied mounting fixtures are secure. All bolts and screws should be fully tightened. Failure to comply with this may result in the unit not being fully supported in the rack and could lead to the product falling from the rack causing personal injury or falling onto other rack components. Ensure that the rack is sufficiently stable by having wall anchors and/or stabilizing legs, and that the floor supporting the rack has sufficient strength for the overall weight loading. Only a fully-trained Service Engineer is authorized to disassemble any other part of the unit, and then only when the unit is powered off. The system has multiple power connections; as a result, you must remove all power leads to completely isolate the power and always use the IEC power cords which are supplied with the system. CAUTION: All Nexsan UNITY expander units and Nexsan E-Series storage units are hot-pluggable. However, the unit that you are adding must be powered on AFTER you connect it to the existing unit. Nexsan UNITY viii

9 Chapter 1 Chapter UNITY2000 1: hardware The Nexsan UNITY2000 deployment includes two UNITY2000 controllers with automatic failover and Active/Active Clustering. The UNITY2000 includes a Host Bus Adapter (SAS) for connectivity to Nexsan UNITY expander units. Each controller includes a chassis inter-connect Host Bus Adapter used for multipathing, providing high speed, low-latency communication between the two UNITY2000 controllers. The UNITY2000 is available in these configurations: Capacity-optimized: The UNITY2000C is an entry-level system comprised of dual-controllers and internal storage. Optionally, you can connect an external Nexsan UNITY2000XC expansion unit to it. UNITY2000C is a 3U chassis and uses 16 drives (14 data NL-SAS drives, 1 FASTier Write Cache device, and 1 FASTier Read Cache device). The FASTier cache devices support both read and write caching. The capacity-optimized configuration is best suited for: backup unstructured files specific applications that benefit from advanced caching video streaming Note The UNITY2000C is available in a half-populated configuration with 9 drives instead of 16 (7 data SAS drives, 1 FASTier Write Cache device, and 1 FASTier Read Cache device). Performance-optimized: The UNITY2000P is an entry-level system comprised of dual-controllers and uses an external Nexsan UNITY2000XP expansion unit. The UNITY2000P is a 2U chassis and uses 24 drives (20 data SAS drives, 2 spare SAS drives, 1 FASTier Write Cache device, and 1 FASTier Read Cache device). The performance-optimized configuration is best suited for: server virtualization environments virtual desktop infrastructure (VDI) databases storage consolidation /multiple workloads Note The UNITY2000P is available in a half-populated configuration with 13 drives instead of 24 (11 data SAS drives, 1 FASTier Write Cache device, 1 FASTier Read Cache device). The UNITY2000 is available in these models: Nexsan UNITY2000C: Intel Xeon CPU, 48 GB of RAM, 120V Nexsan UNITY2000P: Intel Xeon CPU, 48 GB of RAM, 220V

10 Chapter 1: UNITY2000 hardware The amount of storage and FASTier cache devices is allocated as follows: Configuration Storage FASTier Read cache FASTier Write Cache Capacity-optimized: 18TB to 54 TB 400 GB 8 GB With an expansion unit: Up to 108 TB 800 GB 8 GB half-populated: 14TB 400 GB 8 GB Performance-optomized: 5.4 TB to 10.8 TB 400 GB to 800 GB 8 GB With an expansion unit: Up to 21.6 TB 800 GB to 1600 GB 8 GB half-populated: 6.45TB 400 GB 8 GB This section includes these topics: UNITY2000C Front and rear views 3 UNITY2000C General specifications 4 UNITY2000P Front and rear views 5 UNITY2000P General specifications 6 UNITY2000 Front panel LEDs 8 2

11 Chapter 1: UNITY2000 hardware UNITY2000C Front and rear views UNITY2000C Front and rear views These diagrams represent the front and rear views of the capacity-optimized UNITY2000. Figure 1-1: UNITY2000C Front view Figure 1-2: UNITY2000C Rear view Table 1-1: UNITY2000C rear components Rear components 1. Power supply units 2. Fan assemblies 3. On-board GigE LAN ports (2 per node): RIGHT port: Primary data network interface (nx0) LEFT port: Management Interface (nx99) and IPMI interface 4. KVM connections 5. Storage connectivity: Dual-port SAS PCIe to Serial Attached SCSI (HD Mini-SAS) host bus adapter Optional PCIe cards for connectivity 6. Connectivity to Fibre Channel hosts: Dual-port 8Gb Fibre Channel to Express Host Bus Adapter Note If you did not purchase a Fibre Channel card, you can use this slot for an additional network card, which can be any of the supported NICs mentioned below. 7. Network connectivity: 10GbE dual-port network PCIe card with RJ-45 interfaces, or 10GbE dual-port network PCIe card with SFP+ SR interfaces, or GigE quad-port network PCIe card with RJ- 45 interfaces, or 3

12 Chapter 1: UNITY2000 hardware UNITY2000C General specifications UNITY2000C General specifications This section describes the UNITY2000C hardware specifications. Hardware component System Rail kit mounting Redundant components Enclosure physical dimensions Advanced power and cooling units Specifications Up to 16 drives with 3.5'' SAS disk drives 3U enclosure height The rack can have round holes or square roles Maximum distances: 30" (800 mm) 2 power supply units Cooling fans Height 5.2'' 132 mm Width 17.2'' 437 mm Length 24.2'' 615 mm Weight Power supply: 920W 85 lbs. 90 lbs kg (no drives installed) 40.8 kg (all drives installed) Power consumption: varies depending on the number and size of drives, running fans, and room temperature Input voltage: V AC input frequency: 50/60 Hz AC input amperage: Amp DC output: 4 +5V standby; V With Power Distributor: +5V: 45 Amp; +3.3V: 24 Amp; -12V: 0.6 Amp Cooling system: 12 fans (4 cm) 6 counter-rotating fans at the front of each node 6 counter-rotating fans at the rear of each node Power supply: 2 fans (one per power supply) 4

13 Chapter 1: UNITY2000 hardware UNITY2000P Front and rear views UNITY2000P Front and rear views These diagrams represent the front and rear views of the performance-optimized UNITY2000. Figure 1-3: UNITY2000P Front view Figure 1-4: UNITY2000P Rear view Table 1-2: UNITY2000P rear components Rear components 1. Power supply units 2. Fan assemblies 3. On-board GigE LAN ports (2 per node): Right port: Primary data network interface (nx0) Left port: Management Interface (nx99) and IPMI interface 4. KVM connections 5. Storage connectivity: Single SAS port PCIe to Serial Attached SCSI (HD Mini-SAS) host bus adapter Optional PCIe cards for connectivity 6. Connectivity to Fibre Channel hosts: Dual-port 8Gb Fibre Channel to Express Host Bus Adapter Note If you did not purchase a Fibre Channel card, you can use this slot for an additional network card, which can be any of the supported NICs mentioned below. 7. Network connectivity: 10GbE dual-port network card with RJ-45 interfaces, or 10GbE dual-port network card with SFP+ SR interfaces, or GigE quad-port network card with RJ-45 interfaces 5

14 Chapter 1: UNITY2000 hardware UNITY2000P General specifications UNITY2000P General specifications This section describes the UNITY2000P hardware specifications. Hardware component System Rail kit mounting Field Replaceable Units (FRU) Enclosure physical dimensions Power supply units Specifications up to 24 drives (2.5 SAS and/or SSD drives) 2U enclosure height Cable specifications: 19.6''( 500 mm) minimum 118.1'' (3000 mm) maximum Disk drives and drive carrier blanks APC units I/O modules I/O module slot blanks Height 3.5'' 88.9 mm Width 17.6'' 447 mm Length 26.75'' 679 mm Weight Power supply: 920W 85 lbs. 90 lbs. AC Input voltage: V AC Input frequency: Hz AC Input amperage: Amp DC Output: 4 +5V standby; V 38.6 kg (no drives installed) 40.8 kg (all drives installed) With Power Distributor: +5V: 45 Amp; +3.3V: 24 Amp; -12V: 0.6 Amp Maximum output power: 550W Power consumption: varies depending on the number and size of drives, running fans, and room temperature 6

15 Chapter 1: UNITY2000 hardware UNITY2000P General specifications Hardware component Specifications Cooling system: 2 hot-swappable APC units Variable speed blowers, two per APC. Total of four blowers per enclosure. Notes: The UNITY224X/UNITY2000XP can run temporarily (for no more than five minutes) with a single APC unit while you install a new one. You must install a second APC unit as quickly as possible to maintain correct airflow and cooling. In the event of a power supply failure, the blowers in the failed supply will continue to operate on power provided by the redundant APC unit. 7

16 Chapter 1: UNITY2000 hardware UNITY2000 Front panel LEDs UNITY2000 Front panel LEDs The LEDs on the control panel and the drive carriers keep you constantly informed of the overall status of the system and the activity and health of specific components. Control panel LEDs The control panel located on the right side of the UNITY appliance's chassis has several LEDs. These LEDs provide you with critical information related to the node on the same side of the chassis. This table describes what each LED indicates when illuminated and any corrective action you may need to take. Table 1-3: UNITY2000 control panel LEDs LED Description Power Indicates power is being supplied to the system's power supply units. This LED is illuminated when the system is operating. Heartbeat Indicates that power is being supplied to the server board. This LED flashes amber to indicate normal activity. NIC1 Indicates network activity on the LAN1 port when flashing. NIC2 Indicates network activity on the LAN2 port when flashing. Power failure Indicates a power supply module as failed. The second power supply module will take the load and keep the system running but the failed module will need to be replaced. This LED is OFF when the system is operating normally. Overheat/fan failure When this LED flashes, it indicates a fan failure. When it is ON continuously, it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. This LED will remain flashing or on as long as the indicated condition exists. Perform these steps: 8

17 Chapter 1: UNITY2000 hardware UNITY2000 Front panel LEDs LED Description Drive carrier LEDs 1. Check the routing of the cables and make sure all fans are present and operating normally. 2. Check to make sure that the chassis covers are installed. 3. Verify that the heat sinks are installed properly. Each drive carrier on the UNITY appliance's chassis has two LEDs, a green LED on the left to indicate activity, and a red LED on the right to indicate status. Table 1-4: UNITY2000 drive carrier LEDs LED Green Red Description When illuminated, the green LED on the drive carrier indicates the drive is powered on. If this LED is not lit, it means no power is being provided for the drive. A steady red LED indicates a drive failure. A blinking red LED indicates that a RAID rebuild is in progress. 9

18 Chapter 2 Chapter UNITY4000 2: hardware The Nexsan UNITY4000 deployment includes two UNITY4000 controllers with automatic failover and Active/Active Clustering in a 2U form factor. The Nexsan UNITY4000 includes a quad-port Host Bus Adapter (SAS) for connectivity to the Nexsan E-Series. Each controller includes a chassis inter-connect Host Bus Adapter used for multipathing, providing high speed, low-latency communication between the two UNITY4000 controllers. The UNITY4000 is available in these configurations: Capacity-optimized: Mid-range system comprised of dual-controllers and external Nexsan E-Series storage. Up to 2 E-Series head units can be connected, each with up to 2 Expander units. The capacityoptimized version of the UNITY4000 uses Nexsan E18V, E48VT, or E60VT arrays. The capacityoptimized configuration is best suited for: backup unstructured files specific applications that benefit from advanced caching Performance-optimized: Mid-range system comprised of dual-controllers and external Nexsan E-Series storage. Up to 2 E-Series head units can be connected, each with up to 2 Expander units. The performance-optimized version of the UNITY4000 uses Nexsan E32V arrays. The performance-optimized configuration is best suited for: server virtualization environments virtual desktop infrastructure (VDI) databases storage consolidation /multiple workloads The UNITY4000 is available in these models: Nexsan UNITY4000: Intel Xeon CPU, 48 GB of RAM, 120V Nexsan UNITY4000G: Intel Xeon CPU, 48 GB of RAM, 220V For all models, a variety of storage and FASTier Read cache devices can be allocated: Configuration Storage FASTier Read cache FASTier Write cache Capacity-optimized 25 TB to 1,037 TB (2.1 PB) 400 GB to 3,200 GB 8GB Performance-optimized 13 TB to 104 TB 800 GB to 3,200 GB 8GB

19 Chapter 2: UNITY4000 hardware This section includes these topics: UNITY4000 Front and rear views 12 UNITY4000 Front panel LEDs 13 UNITY4000 General specifications 14 11

20 Chapter 2: UNITY4000 hardware UNITY4000 Front and rear views UNITY4000 Front and rear views These diagrams represent the front and rear views of the UNITY4000. Figure 2-1: UNITY4000 Front view Figure 2-2: UNITY4000 Rear view Table 2-1: UNITY4000 rear components Rear components 1. Power supply units 2. Fan assemblies 3. On-board GigE LAN ports (2 per node): RIGHT port: Network connectivity with the UNITY Vault Protection Module LEFT port: Management Interface (nx99) and IPMI interface 4. KVM connections 5. Storage connectivity: SAS Quad port PCIe to Serial Attached SCSI (HD Mini-SAS) host bus adapter Optional PCIe cards for connectivity 6. Connectivity to Fibre Channel hosts: Dual-port 8Gb Fibre Channel to Express Host Bus Adapter Note If you did not purchase a Fibre Channel card, you can use this slot for an additional network card, which can be any of the supported NICs mentioned below. 7. Network connectivity (nx0): 10GbE Dual-port Network card with RJ-45 interfaces, or 10GbE Dual-port Network card with SFP+ SR interfaces, or GigE Quad-port Network card with RJ-45 interfaces 12

21 Chapter 2: UNITY4000 hardware UNITY4000 Front panel LEDs UNITY4000 Front panel LEDs The LEDs on the control panel and the drive carriers keep you constantly informed of the overall status of the system and the activity and health of specific components. Control panel LEDs The control panel located on the right side of the UNITY appliance's chassis has several LEDs. These LEDs provide you with critical information related to the node on the same side of the chassis. This table describes what each LED indicates when illuminated and any corrective action you may need to take. Table 2-2: UNITY4000 control panel LEDs LED Description Power Indicates power is being supplied to the system's power supply units. This LED is illuminated when the system is operating. Heartbeat Indicates that power is being supplied to the server board. This LED flashes amber to indicate normal activity. NIC1 Indicates network activity on the LAN1 port when flashing. NIC2 Indicates network activity on the LAN2 port when flashing. Power failure Indicates a power supply module as failed. The second power supply module will take the load and keep the system running but the failed module will need to be replaced. This LED is OFF when the system is operating normally. Overheat/fan failure When this LED flashes, it indicates a fan failure. When it is ON continuously, it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. This LED will remain flashing or on as long as the indicated condition exists. Perform these steps: 13

22 Chapter 2: UNITY4000 hardware UNITY4000 General specifications LED Description 1. Check the routing of the cables and make sure all fans are present and operating normally. 2. Check to make sure that the chassis covers are installed. 3. Verify that the heat sinks are installed properly. Drive carrier LEDs Each drive carrier on the UNITY appliance's chassis has two LEDs, a green LED on the left to indicate activity, and a red LED on the right to indicate status. Table 2-3: UNITY4000 drive carrier LEDs LED Green Red Description When illuminated, the green LED on the drive carrier indicates the drive is powered on. If this LED is not lit, it means no power is being provided for the drive. A steady red LED indicates a drive failure. A blinking red LED indicates that a RAID rebuild is in progress. UNITY4000 General specifications This section describes the UNITY4000 hardware specifications. Hardware component System Rail kit mounting Field Replaceable Units (FRU) Enclosure physical dimensions Power supply units Specifications up to 24 drives (2.5 SAS and/or SSD drives) 2U enclosure height Cable specifications: 19.6''( 500 mm) minimum 118.1'' (3000 mm) maximum Disk drives and drive carrier blanks APC units I/O modules I/O module slot blanks Height 3.5'' 88.9 mm Width 17.6'' 447 mm Length 26.75'' 679 mm Power supply: 720W Power supply: 920W 14

23 Chapter 2: UNITY4000 hardware UNITY4000 General specifications Hardware component Specifications AC Input voltage: V AC Input frequency: Hz AC Input amperage: 4-9 Amp AC Input amperage: Amp DC Output: 3 +5V standby; V DC Output: 4 +5V standby; V With Power Distributor: +5V: 45 Amp; +3.3V: 24 Amp; -12V: 0.6 Amp Maximum output power: 550W Power consumption: varies depending on the number and size of drives, running fans, and room temperature Cooling system: 2 hot-swappable APC units Variable speed blowers, two per APC. Total of four blowers per enclosure. Notes: The UNITY224X/UNITY2000XP can run temporarily (for no more than five minutes) with a single APC unit while you install a new one. You must install a second APC unit as quickly as possible to maintain correct airflow and cooling. In the event of a power supply failure, the blowers in the failed supply will continue to operate on power provided by the redundant APC unit. 15

24 Chapter 3 Chapter UNITY5000 3: hardware The UNITY5000 is a high-end storage unit in a 3U form factor with no single point-of-failure architecture, including: dual redundant storage controllers with automatic failover and full Active/Active Clustering capability; redundant, hot-swappable power supply units; and interface link aggregation for full networking redundancy. The UNITY5000 also provides a dedicated management/ipmi network interface. The UNITY5000 is available in these configurations: Nexsan NST5100 : Nexsan NST5110 : NAS (CIFS/NFS) support only Nexsan NST5120 : Block (iscsi and Fibre Channel) support Nexsan NST5130 : Block (iscsi and Fibre Channel) and NAS (CIFS/NFS) support Nexsan NST5300 : Nexsan NST5310 : NAS (CIFS/NFS) support only Nexsan NST5320 : Block (iscsi and Fibre Channel) support Nexsan NST5330 : Block (iscsi and Fibre Channel) and NAS (CIFS/NFS) support This section includes these topics: UNITY5000 Front and rear views 17 UNITY5000 Front panel LEDs 18 UNITY5000 General specifications 20

25 Chapter 3: UNITY5000 hardware UNITY5000 Front and rear views UNITY5000 Front and rear views These diagrams represent the front and rear views of the UNITY5000. Figure 3-1: UNITY5000 Front view Figure 3-2: UNITY5000 Rear view Table 3-1: UNITY5000 rear components Rear components 1. Power supply units 2. Fan assemblies 3. On-board GigE LAN ports (2 per node): Top port (LAN2): LAN/data network interface (on some NST5000 models) Bottom port (LAN1): Management and IPMI interfaces (on all models) 4. KVM connections 5. Storage connectivity: Single SAS port PCIe to Serial Attached SCSI (HD Mini-SAS) host bus adapter Optional PCIe cards for connectivity 6. Network connectivity: 10GbE dual-port network PCIe card with RJ-45 interfaces, or 10GbE dual-port network PCIe card with SFP+ SR interfaces, or GigE dual-port network PCIe card with RJ- 45 interfaces, or GigE quad-port network PCIe card with RJ- 45 interfaces 17

26 Chapter 3: UNITY5000 hardware UNITY5000 Front panel LEDs Rear components Optional PCIe cards for connectivity 7. Host connectivity: SAS quad-port PCIe to Serial Attached SCSI (SAS) host bus adapter, or Fibre Channel quad-port 8Gb to PCI Express Host Bus Adapter Note Data connectivity cards are NOT optional on the NST5300. UNITY5000 Front panel LEDs The LEDs on the control panel and the drive carriers keep you constantly informed of the overall status of the system and the activity and health of specific components. Control panel LEDs The control panel located on the right side of the UNITY appliance's chassis has several LEDs. These LEDs provide you with critical information related to the node on the same side of the chassis. This table describes what each LED indicates when illuminated and any corrective action you may need to take. Table 3-2: UNITY5000 control panel LEDs LED Description Power Indicates power is being supplied to the system's power supply units. This LED is illuminated when the system is operating. Heartbeat Indicates that power is being supplied to the server board. This LED flashes amber to indicate normal activity. NIC1 Indicates network activity on the LAN1 port when flashing. NIC2 Indicates network activity on the LAN2 port when flashing. Power failure Indicates a power supply module as failed. The second power supply module will take the load and keep the system running but the failed module will need to be replaced. This LED is OFF when the system is operating normally. 18

27 Chapter 3: UNITY5000 hardware UNITY5000 Front panel LEDs LED Description Drive carrier LEDs Overheat/fan failure When this LED flashes, it indicates a fan failure. When it is ON continuously, it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. This LED will remain flashing or on as long as the indicated condition exists. Perform these steps: 1. Check the routing of the cables and make sure all fans are present and operating normally. 2. Check to make sure that the chassis covers are installed. 3. Verify that the heat sinks are installed properly. Each drive carrier on the UNITY appliance's chassis has two LEDs, a green LED on the left to indicate activity, and a red LED on the right to indicate status. Table 3-3: UNITY5000 drive carrier LEDs LED Green Red Description When illuminated, the green LED on the drive carrier indicates the drive is powered on. If this LED is not lit, it means no power is being provided for the drive. A steady red LED indicates a drive failure. A blinking red LED indicates that a RAID rebuild is in progress. 19

28 Chapter 3: UNITY5000 hardware UNITY5000 General specifications UNITY5000 General specifications This section describes the UNITY5000 hardware specifications. Hardware component System Rail kit mounting Redundant components Enclosure physical dimensions Advanced power and cooling units Specifications Up to 16 drives with 3.5'' SAS disk drives 3U enclosure height The rack can have round holes or square roles Note The NST5000 rail kit does not handle round holes. Imation must provide adapters to compensate. Maximum distances: 30" (800 mm) 2 power supply units Cooling fans Height 5.2'' 132 mm Width 17.2'' 437 mm Length 24.2'' 615 mm Weight Power supply: 1,200W NST5100/NST5100X 84 lbs NST lbs 38.1 Kg 30.1 Kg Power consumption: varies depending on the number and size of drives, running fans, and room temperature Input voltage: V AC input voltage: 240V AC input frequency: 50/60 Hz AC input amperage: Amp DC output voltage: 12V 240V), +5Vsb 240V, 100V) DC output: 4 +5V standby; V With Power Distributor: +5V: 45 Amp; +3.3V: 24 Amp; -12V: 0.6 Amp Cooling system: 12 fans (4 cm) 6 counter-rotating fans at the front of each node 6 counter-rotating fans at the rear of each node Power supply: 2 fans (one per power supply) 20

29 Chapter 4 Chapter UNITY6000 4: hardware The Nexsan UNITY6000 deployment includes two UNITY6000 controllers with automatic failover and Active/Active Clustering. Each controller includes two Host Bus Adapters (Fibre Channel or SAS) for connectivity to the Nexsan E-Series, two Host Bus Adapters (Fibre Channel) for host access, as well as a 10GbE I/O module for data connectivity. Each controller also includes a chassis inter-connect Host Bus Adapter used for multipathing, providing high speed, low-latency communication between the two UNITY6000 controllers. The UNITY6000 provides block (iscsi and Fibre Channel) and NAS (CIFS/NFS) support for all available models: UNITY6530 : Dual Intel CPU, 96 GB of RAM 120 Volts UNITY6530G : Dual Intel CPU, 96 GB of RAM 230 Volts Fibre Channel allows exposure to all ports, all LUNs. This section includes these topics: UNITY6000 Hardware components 22 UNITY6000 Front and rear views 23 UNITY6000 Front panel LEDs 24 UNITY6000 Rear panel LEDs 26 UNITY6000 General specifications 28

30 Chapter 4: UNITY6000 hardware UNITY6000 Hardware components UNITY6000 Hardware components This table lists the hardware components of the UNITY6000. Table 4-1: UNITY6000 hardware components Component SAS connectors Drive bays System power Rear ports for the UNITY6000 Front panel Cooling system Description High Performance 6Gb/s SAS controllers Up to 24 hot-swap drive bays with 2.5" FASTier Read cache devices 2 redundant, hot-swappable power supply units ( AC 750W Platinum). This power redundancy feature allows you to replace a failed power module without shutting down the system. The rear of the chassis includes 4 on-board gigabit Ethernet (GigE) RJ-45 ports, with 1 port dedicated to the UNITY6000 management interface and IPMI. Each UNITY6000 controller includes two Host Bus Adapters (Fibre Channel or SAS) for connectivity to Nexsan storage, two Host Bus Adapters (Fibre Channel) for host access, as well as a 10GbE I/O module for data connectivity. The front panel has one control panel to provide you with system monitoring and control. LEDs indicate system power, network (NIC) activity, system overheat and power supply failure. Each drive carrier also has LEDs to indicate the drive status. The UNITY6000 chassis has five redundant, hot-swappable fans, located behind the drive bays. The five 60x38-mm fans and an embedded fan for each installed power supply, provide the primary airflow for the system. The system is designed for fan redundancy when configured with two power supply modules. Fan redundancy is lost if more than one fan is in a failed state. 22

31 Chapter 4: UNITY6000 hardware UNITY6000 Front and rear views UNITY6000 Front and rear views These diagrams represent the front and rear views of the UNITY6000. Figure 4-1: UNITY6000 Front view Figure 4-2: UNITY6000 Rear view Table 4-2: UNITY6000 rear components Rear components 1. Power supply unit 1 2. Power supply unit 2 3. NIC 1: management interface (nx99) and IPMI 4. NIC 2: data connectivity with UNITY Vault Protection Module 5. NIC 3: unused 6. NIC 4: unused 7. Video port (for console access) 8. RJ-45 Serial port A (unused) 9. 3 USB ports (keyboard/mouse connectivity) 10. RJ-45 NIC port (optional IPMI port) GbE I/O module for data connectivity (configured as the primary data network interface, nx0) Note The 10GbE I/O module auto-detects network speed. The Dual-port RJ-45 10GbE I/O module is required for networks using 1GbE connection. 12. Host Bus Adapters for connectivity (unused reserved for future use) 13. Dual-port 8Gb Host Bus Adapters for connectivity to Fibre Channel or GbE hosts 14. Host Bus Adapters for connectivity to Nexsan storage: SAS Dual-port or Quad-port 8Gb Host Bus Adapters Fibre Channel Dual-port or Quad-port HBAs also available; please see your Imation sales representative. 23

32 Chapter 4: UNITY6000 hardware UNITY6000 Front panel LEDs Rear components UNITY6000 Front panel LEDs 15. Chassis inter-connect Host Bus Adapter with QSFP+ to QSFP+ (SFF-8436 to SFF-8436) external cables (also used for private0 network interface) 16. Serial port B (unused) There are several LEDs on the control panel of the UNITY6000, and on the drive carriers, to keep you constantly informed of the overall status of the system and the activity and health of specific components. Control panel LEDs The control panel located on the right side of the UNITY6000 have several LEDs. These LEDs provide you with critical information related to the corresponding node. This table describes what each LED indicates when illuminated and any corrective action you may need to take. Table 4-3: UNITY6000 Control panel LEDs LED Description Power LED: Indicates power is being supplied to the system's power supply units. This LED is illuminated when the system is operating. System status LED: Bi-color (Green/Amber) indicator that shows the current health of the server system. The system provides two locations for this feature; one is located on the Front Control Panel, the other is located on the back edge of the server board, viewable from the back of the system. Both LEDs are tied together and show the same state. Off indicates that the system is powered off. A solid green LED indicates that the system is running and is healthy. 24

33 Chapter 4: UNITY6000 hardware UNITY6000 Front panel LEDs LED Description A blinking green LED indicates the system is degraded although still functional or it indicates the system is operating in a redundant state but with an impending failure warning. Possible causes can be: Redundancy loss, such as power-supply or fan Fan warning or failure when the number of fully operational fans is more than minimum number needed to cool the system Non-critical threshold crossed Temperature, voltage, input power to power supply, output current for main power rail from power supply and Processor Thermal Control sensors Power supply predictive failure occurred while redundant power supply configuration was present. Internal memory errors Battery failure Power Unit sensor offset for configuration A blinking amber LED indicates that the system is operating in a degraded state and is likely to fail. Possible causes can be: Critical threshold crossed Voltage, temperature, input power to power supply, output current for main power rail from power supply and thermal sensors Minimum number of fans to cool the system are not present or failed Hard drive fault Power Unit Redundancy sensor indicates not enough power supplies present Memory uncorrectable errors A solid amber LED indicates that the system is halted. Possible causes can be: CPU failure Power fault Runtime memory uncorrectable error Temperature issues Fatal error in processor initialization, such as processor family or model not identical Drive Activity LED: Indicates drive activity from the on-board hard disk controllers. The server board also provides a header giving access to this LED for add-in controllers. System ID button with integrated LED: Toggles the integrated ID LED and the Blue server board ID LED on and off. The System ID LED identifies the system for maintenance when the system is installed in a rack of similar server systems. System cold reset button: When pressed, this button reboots and re-initializes the system. 25

34 Chapter 4: UNITY6000 hardware UNITY6000 Rear panel LEDs LED Description Network Activity LEDs: The Front Control Panel includes an activity LED indicator for each on-board Network Interface Controller (NIC). When a network link is detected, the LED turns on solid. The LED blinks once network activity occurs at a rate that is consistent with the amount of network activity that is occurring. Non-maskable interrupt (NMI) button: When the NMI button is pressed, it puts the server in a halt state and issues a non-maskable interrupt. This can be useful when performing diagnostics for a given issue where a memory download is necessary to help determine the cause of the problem. To prevent an inadvertent system halt, the actual NMI button is located behind the Front Control Panel faceplate where it is only accessible with the use of a small tipped tool like a pin or paper clip. Drive carrier LEDs Each drive carrier on the UNITY6000 has two LEDs, a green LED on the left to indicate activity, and an amber LED on the right to indicate status. Table 4-4: UNITY6000 Drive carrier LEDs LED Green Amber Description A steady green LED indicates the drive is powered on and there is no drive activity. A green LED blinking off indicates the drive is powered on and the drive is processing a command. A steady amber LED indicates a drive failure. A blinking amber LED indicates that a RAID rebuild is in progress. UNITY6000 Rear panel LEDs You can view the status of the connection between the two UNITY6000 units by looking at the LED color on the chassis inter-connect HBA. The chassis inter-connect HBA has two ports, and each port has two LEDs, one at the top and one at the bottom. For this release, the bottom LEDs are not enabled, so you see colors on the top LEDs only. Table 4-5: UNITY6000 chassis inter-connect HBA LEDs Left (top) LED Right (top) LED Description When starting the UNITY6000 No color No color The HBA driver is off. Red blinking slowly The cable on the left port is disconnected. Red blinking slowly The cable on the right port is disconnected. Green blinking slowly The cable on the left port is connected, but the handshake is not established with the other 26

35 Chapter 4: UNITY6000 hardware UNITY6000 Rear panel LEDs Left (top) LED Right (top) LED Description UNITY6000 controller. Green blinking slowly The cable on the right port is connected, but the handshake is not established with the other UNITY6000 controller. Solid Green The cable on the left port is connected, and the handshake is established with the other UNITY6000 controller. Solid Green The cable on the right port is connected, and the handshake is established with the other UNITY6000 controller. Scenarios Solid Green Red blinking slowly The cable on the left port is connected, and the handshake is established with the other UNITY6000 controller. The cable on the right port is disconnected. Green blinking slowly Green blinking slowly Both cables are connected, but the handshake is not established with the other UNITY6000 controller. Solid green Solid green Both cables are connected and the handshake is established with the other UNITY6000 controller. Issues Alternating between red and green Alternating between red and green The connection is resetting. Solid red Solid red The HBA driver is in error state. Red blinking fast Red blinking fast The HBA driver is in error state. 27

36 Chapter 4: UNITY6000 hardware UNITY6000 General specifications UNITY6000 General specifications This section describes the UNITY6000 hardware specifications. Hardware component System Rail kit mounting Field Replaceable Units (FRU) Enclosure physical dimensions Power supply units Specifications up to 24 drives (2.5 SAS and/or SSD drives) 2U enclosure height Cable specifications: 19.6''( 500 mm) minimum 118.1'' (3000 mm) maximum Disk drives and drive carrier blanks APC units I/O modules I/O module slot blanks Height 3.5'' 88.9 mm Width 17.6'' 447 mm Length 26.75'' 679 mm Power supply: 750W Power supply: 720W AC Input voltage: V AC Input frequency: Hz AC Input amperage: 4-9 Amp DC Output: 3 +5V standby; V Maximum output power: 550W Power consumption: varies depending on the number and size of drives, running fans, and room temperature Cooling system: 2 hot-swappable APC units Variable speed blowers, two per APC. Total of four blowers per enclosure. Notes: The UNITY224X/UNITY2000XP can run temporarily (for no more than five minutes) with a single APC unit while you install a new one. You must install a second APC unit as quickly as possible to maintain correct airflow and cooling. In the event of a power supply failure, the blowers in the failed supply will continue to operate on power provided by the redundant APC unit. 28

37 Chapter 5 Chapter UNITY 5: Vault Protection Module hardware The UNITY Vault Protection Module (UNITY VPM) provides battery backup and protection to the UNITY4000/ UNITY6000 in case of power outage. Both controllers are connected to two UNITY VPM units for power redundancy. The UNITY VPM units provide power to the UNITY appliance for five minutes so that all I/O operations saved on the FASTier write cache, since the power interruption, can be written to an internal Solid State Drive (SSD) in each controller. Under normal conditions, each UNITY VPM powers its own controller, and therefore has no need to share the power load with the other UNITY VPM. The UNITY VPM is available in two models: 5P 1550GR 208V/230V unit 5P 1500R 120V unit This section includes these topics: UNITY Vault Protection Module front view 30 UNITY Vault Protection Module rear view 30 UNITY Vault Protection Module front panel LEDs and LCD screen 31 Using the UNITY Vault Protection Module LCD menu 33 Modifying the UNITY Vault Protection Module settings 34 UNITY Vault Protection Module general specifications 38

38 Chapter 5: UNITY Vault Protection Module hardware UNITY Vault Protection Module front view UNITY Vault Protection Module front view This diagram represents the front view of the UNITY Vault Protection Module (UNITY VPM). Figure 5-1: UNITY VPM front view The front view is equipped with an LCD screen that provides status on operations, load/equipment, battery, as well as information on efficiency. By default, the LCD screen displays a screen saver after 5 minutes of inactivity. Figure 5-2: UNITY VPM LCD screen and LEDs UNITY Vault Protection Module rear view These diagrams represent the rear views of the UNITY Vault Protection Module (UNITY VPM), per model type. Figure 5-3: UNITY VPM rear view 5P 1500R Table 5-1: UNITY VPM rear components 5P 1500R 5P 1500R rear components 1. Ethernet connectivity with the UNITY appliance 2. LED indicating the Site Wiring Fault (SWF) alarm 3. Connection to AC power source 4. RS232 communication port (not used) 7. Ground screw 8. Two power connections; one goes to the first UNITY appliance controller and the other goes to the second UNITY appliance controller. 9. Two programmable outlets for Group 1 (not used) 30

39 Chapter 5: UNITY Vault Protection Module hardware UNITY Vault Protection Module front panel LEDs and LCD screen 5P 1500R rear components 5. USB communication port (not used) 6. Connector for ROO (remote ON/OFF) or RPO (Remote Power OFF) control (not used) 10. One programmable outlet for Group 2 (not used) Figure 5-4: UNITY VPM rear view 5P 1550GR Table 5-2: UNITY VPM rear components 5P 1550GR 5P 1550GR Rear components 1. Ethernet connectivity with the UNITY appliance 2. Connection to AC power source 3. RS232 communication port (not used) 4. USB communication port (not used) 5. Connector for ROO (remote ON/OFF) or RPO (Remote Power OFF) control (not used) 6. Ground screw 7. Three power connections; one goes to the first UNITY appliance controller and another one goes to the second UNITY appliance controller. (The third outlet is not used.) 8. Two programmable outlets for Group 1 (not used) 9. One programmable outlet for Group 2 (not used) UNITY Vault Protection Module front panel LEDs and LCD screen This table describes what each LED indicates and any corrective action you may need to take. LED Description The UNITY VPM is operating normally. Green The UNITY VPM is running on battery mode. Yellow Red The UNITY VPM is powered on and has an active alarm; for possible causes, see Troubleshooting on the next page. This table describes status information provided by the UNITY VPM LCD screen. 31

40 Chapter 5: UNITY Vault Protection Module hardware UNITY Vault Protection Module front panel LEDs and LCD screen Status Normal mode Description The UNITY VPM is operating normally. Standby mode The UNITY VPM is not powered on. Press the power button to start the UNITY VPM. In AVR mode No beep On Battery The UNITY VPM is operating normally but the device voltage in outside normal mode threshold. This can happen if the UNITY VPM is powering the UNITY appliance through an automatic voltage regulation device. The UNITY appliance is still normally protected. The UNITY VPM is powering the UNITY appliance with the battery power. Prepare the UNITY appliance for shutdown. Battery LED is on and there is 1 beep every 10 seconds End of backup time 1 beep every 3 seconds The UNITY VPM is powering the UNITY appliance with the battery power and the battery is running low. This warning is approximate, and the actual time to shutdown may vary significantly. Depending on the UNITY VPM load, the "Battery Low" warning may occur before the battery reaches 20 % capacity. Troubleshooting Batteries disconnected Overload End of battery life The internal batteries are disconnected or the UNITY VPM does not recognize the internal batteries. Verify that all batteries are properly connected. If the condition persists, call Imation Technical Support. There is a power overload; power requirements exceed the UNITY VPM capacity (greater than 105 % of nominal). The UNITY VPM continues to operate, but may shut down if the load increases. The end of the battery life is reached. Contact Imation Technical Support for battery replacement. Event An event is occurring. Address the event so that the UNITY VPM goes back to normal mode. Fault The UNITY VPM has an internal fault and does not protect the UNITY appliance anymore. If this happens, take note of the alarm message and the UNITY VPM serial number, then call Imation Technical Support. 32

41 Chapter 5: UNITY Vault Protection Module hardware Using the UNITY Vault Protection Module LCD menu Using the UNITY Vault Protection Module LCD menu This section describes the main menu functions of the UNITY VPM LCD screen. For an extended list of menus, see Modifying the UNITY Vault Protection Module settings on the next page. To use the UNITY VPM menus: 1. Press the Enter button to activate the menu options. 2. Press the two middle buttons ( and ) to scroll through the menu structure. 3. Press the Enter button to select an option. 4. Press the button to cancel or return to the previous menu. Table 5-3: UNITY VPM LCD display functions Main menu Submenu Display information / menu function Measurements Load W VA / Load A pf / Output V Hz / Input V Hz / Battery V min / Efficiency / Power usage Control Load Segments Group 1: ON / OFF Group 2: ON / OFF Note These commands overrule user settings for load segments. Start battery test Reset fault state Restore factory settings Reset power usage Starts a manual battery test Clears active faults the UNITY VPM must be restarted. Returns all settings to original values. Clears power usage measurements. Settings Local settings Sets product general parameters. Input / output settings ON / OFF settings Battery settings Sets Input and output parameters. Sets ON / OFF conditions. Sets battery configuration. Fault log Identification Displays event log or alarms. UNITY VPM Type / Part Number / Serial Number / Firmware release / Com card address 33

HYPER-UNIFIED STORAGE. Nexsan Unity

HYPER-UNIFIED STORAGE. Nexsan Unity HYPER-UNIFIED STORAGE Nexsan Unity Storage Expansion Reference Guide Unity v. 5.1 NEXSAN 325 E. Hillcrest Drive, Suite #150 Thousand Oaks, CA 91360 USA Printed Wednesday, November 28, 2018 www.nexsan.com

More information

HYPER-UNIFIED STORAGE. Nexsan Unity

HYPER-UNIFIED STORAGE. Nexsan Unity HYPER-UNIFIED STORAGE Nexsan Unity Upgrade Guide Applying Upgrades to Unity Nexsan 900 E. Campbell, CA 95008 p. 866.263.9726 www.nexsan.com Copyright 2010 2017 Nexsan, Inc. All Rights Reserved. Trademarks

More information

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment DATASHEET TM NST6000 UNIFIED HYBRID STORAGE Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment UNIFIED The Nexsan NST6000 unified hybrid storage system is ideal for organizations

More information

NEXSAN E-SERIES. Nexsan E32V and Nexsan E18 /E18V RAID Storage Units

NEXSAN E-SERIES. Nexsan E32V and Nexsan E18 /E18V RAID Storage Units NEXSAN E-SERIES Nexsan E32V and Nexsan E18 /E18V RAID Storage Units Part Number: P0450135 Rev: A NEXSAN 910 E Hamilton Ave, Campbell, CA 95008 p. 1.760.690.1111 Copyright 2010 2016 Nexsan. All Rights Reserved

More information

HYPER-UNIFIED STORAGE. Nexsan Unity

HYPER-UNIFIED STORAGE. Nexsan Unity HYPER-UNIFIED STORAGE Nexsan Unity Hardware Maintenance Guide Firmware Version Unity v. 5.1 NEXSAN 325 E. Hillcrest Drive, Suite #150 Thousand Oaks, CA 91360 USA Printed Wednesday, January 02, 2019 www.nexsan.com

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

HYPER-UNIFIED STORAGE. Nexsan Unity

HYPER-UNIFIED STORAGE. Nexsan Unity HYPER-UNIFIED STORAGE Nexsan Unity Troubleshooting Guide NEXSAN 325 E. Hillcrest Drive, Suite #150 Thousand Oaks, CA 91360 USA Printed Friday, October 26, 2018 www.nexsan.com Copyright 2010 2018 Nexsan

More information

DNS-2608 Enterprise JBOD Enclosure User Manual

DNS-2608 Enterprise JBOD Enclosure User Manual DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved. www.dataonstorage.com 1 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

HYPER-UNIFIED STORAGE. Nexsan Unity

HYPER-UNIFIED STORAGE. Nexsan Unity HYPER-UNIFIED STORAGE Nexsan Unity Snapshots and Replication Guide Firmware Version: Unity 2.0 Nexsan 900 E. Campbell, CA 95008 p. 866.263.9726 www.nexsan.com Copyright 2010 2017 Nexsan, Inc. All Rights

More information

NEXSAN E-SERIES. Nexsan E60 /E60V /E60VT /E60P and Nexsan E48 /E48V /E48VT /E48P RAID Storage Units. FRU Removal and Replacement Guide

NEXSAN E-SERIES. Nexsan E60 /E60V /E60VT /E60P and Nexsan E48 /E48V /E48VT /E48P RAID Storage Units. FRU Removal and Replacement Guide NEXSAN E-SERIES E60 /E60V /E60VT /E60P and E48 /E48V /E48VT /E48P RAID Storage Units Part Number: P0450139 Rev: A NEXSAN 910 E Hamilton Ave, Campbell, CA 95008 p. 1.760.690.1111 Copyright 2010 2016. All

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

Dell SCv3000 and SCv3020 Storage System Owner s Manual

Dell SCv3000 and SCv3020 Storage System Owner s Manual Dell SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

Dell SC7020 and SC7020F Storage Systems Owner s Manual

Dell SC7020 and SC7020F Storage Systems Owner s Manual Dell SC7020 and SC7020F Storage Systems Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Hardware Owner s Manual

Hardware Owner s Manual Dell PowerVault MD3000 RAID Enclosure Hardware Owner s Manual www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

NEXSAN E-SERIES. Nexsan E60 /E60V /E60VT /E60P and Nexsan E48 /E48V /E48VT /E48P RAID Storage Units. Installation Guide. Part Number: P Rev: A

NEXSAN E-SERIES. Nexsan E60 /E60V /E60VT /E60P and Nexsan E48 /E48V /E48VT /E48P RAID Storage Units. Installation Guide. Part Number: P Rev: A NEXSAN E-SERIES E60 /E60V /E60VT /E60P and E48 /E48V /E48VT /E48P RAID Storage Units Part Number: P0450140 Rev: A NEXSAN 910 E Hamilton Ave, Campbell, CA 95008 p. 1.760.690.1111 Copyright 2010 2016. All

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

N3240 Installation and Setup Instructions

N3240 Installation and Setup Instructions IBM System Storage N3240 Installation and Setup Instructions Covering the N3240 model GA32-2203-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B

NGFW Security Management Center Appliance. for Forcepoint Next Generation Firewall Hardware Guide. Revision B NGFW Security Management Center Appliance for Forcepoint Next Generation Firewall Hardware Guide Revision B Contents Introduction on page 2 Find product documentation on page 2 Supported software on page

More information

Introduction to NetApp E-Series E2700 with SANtricity 11.10

Introduction to NetApp E-Series E2700 with SANtricity 11.10 d Technical Report Introduction to NetApp E-Series E2700 with SANtricity 11.10 Todd Edwards, NetApp March 2014 TR-4275 1 Introduction to NetApp E-Series E2700 with SANtricity 11.10 TABLE OF CONTENTS 1

More information

SAS JBOD Installation Reference Guide Revision 1.0

SAS JBOD Installation Reference Guide Revision 1.0 SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-4i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.1 DB15-000858-02 Revision History Version and Date Description of Changes Final Version 2.1, Updated

More information

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide 1800 19th Street / Bakersfield, CA 93301 / Tel: 661.716.7600 / Toll Free: 877.447.6244 / www.lightspeedsystems.com Table of Contents

More information

CSU 0111 Compute Sled Unit

CSU 0111 Compute Sled Unit CSU 0111 Compute Sled Unit Ericsson Software Defined Infrastructure Ericsson Compute Sled Unit (CSU) 0111 is a self-managed compute resource designed to slide into the CPA 111 chassis. Four CSUs can fit

More information

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.3 DB15-000902-03 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

NEXSAN E-SERIES. Nexsan E32XV and Nexsan E18X /E18XV RAID Storage Expansion Units

NEXSAN E-SERIES. Nexsan E32XV and Nexsan E18X /E18XV RAID Storage Expansion Units NEXSAN E-SERIES E32XV and E18X /E18XV RAID Storage Expansion Units Part Number: P0450138 Rev: A NEXSAN 910 E Hamilton Ave, Campbell, CA 95008 p. 1.760.690.1111 Copyright 2010 2018. All Rights Reserved

More information

N3220 Installation and Setup Instructions

N3220 Installation and Setup Instructions IBM System Storage N3220 Installation and Setup Instructions Covering the N3220 model GA32-2202-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions... Table of Contents Quick Install Guide page 1 EN English Table of Contents 1. Introduction... 2 1.1 Safety... 2 1.2 Rack System Precautions... 2-3 1.3 ESD Precautions... 3... 3 1... 3 2 Fitting PSU s...

More information

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-16e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.2 DB15-000982-03 For a comprehensive list of changes to this document, see the Revision History.

More information

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-8e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.3 DB15-000859-04 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment. The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment. IPMI Control Dual Power Supplies Enhanced Metadata Uptime Storage Up to 1.3M IOPS and 5,500 MBps throughput

More information

Dell EMC PowerVault MD3460 Storage Arrays

Dell EMC PowerVault MD3460 Storage Arrays Dell EMC PowerVault MD3460 Storage Arrays Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

Xcellis Workflow Extender (R520) Site Planning Guide

Xcellis Workflow Extender (R520) Site Planning Guide Xcellis Workflow Extender Contents Xcellis Workflow Extender (R520) Site Planning Guide Product Overview Product Overview... 1 Installation Requirements... 2 Rack Compatibility... 2 Setup... 2 Installation

More information

Cisco NAC Appliance Hardware Platforms

Cisco NAC Appliance Hardware Platforms 1 CHAPTER This chapter provides general information on the Cisco NAC Appliance network access control system, as well as hardware specifications for all Clean Access Manager (CAM) and Clean Access Server

More information

Dell EMC ME4 Series JBOD 5U84 Enclosure

Dell EMC ME4 Series JBOD 5U84 Enclosure Dell EMC ME4 Series JBOD 5U84 Enclosure Deployment Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance Data Sheet Cisco MCS 7845-H1 Unified CallManager Appliance THIS PRODUCT IS NO LONGER BEING SOLD AND MIGHT NOT BE SUPPORTED. READ THE END-OF-LIFE NOTICE TO LEARN ABOUT POTENTIAL REPLACEMENT PRODUCTS AND

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS SPEC SHEET DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Data Domain Systems Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.2 DB15-000984-02 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS SPEC SHEET DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Data Domain Systems Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery

More information

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

Mercury Helios ASSEMBLY MANUAL & USER GUIDE Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp

More information

LifeSize ClearSea Installation Guide August 2012

LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea LifeSize ClearSea Virtual Machine LifeSize ClearSea Installation Guide 2 LifeSize ClearSea This guide describes how to install and configure

More information

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.

More information

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 64 Bays SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Preface... 4 Before You Begin... 5 Safety Guidelines... 5 Controller Configurations... 5 Packaging, Shipment and Delivery... 5 Unpacking

More information

ReadyNAS OS 6 Rack-Mount Hardware Manual

ReadyNAS OS 6 Rack-Mount Hardware Manual Rack-Mount Hardware Manual Model ReadyNAS 2120 ReadyNAS 2120 v2 ReadyNAS 3130 ReadyNAS 3138 ReadyNAS 3220 ReadyNAS 3312 ReadyNAS 4220 ReadyNAS 4312 ReadyNAS 4360 April 2017 202-11272-08 350 E. Plumeria

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

Dell EMC Data Domain Hardware Features and Specifications Guide

Dell EMC Data Domain Hardware Features and Specifications Guide Dell EMC Data Domain Hardware Features and Specifications Guide Version 6.1 302-004-902 REV 01 Copyright 2018 Dell Inc. or its subsidiaries. All rights reserved. Published July 2018 Dell believes the information

More information

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014 0 Copyright Fujitsu, Release June 2014 Highlights The passive storage subsystem accommodates up to 240 HDDs 3.5" SAS 2.0 Nearline SAS 7200 rpm, max. storage capacity 960 TB 1) One or two 6 Gbit/s SAS interfaces

More information

Vess. Architectural & Engineering Specifications For Video Surveillance. A2600 Series. Version: 1.2 Sep, 2012

Vess. Architectural & Engineering Specifications For Video Surveillance. A2600 Series.  Version: 1.2 Sep, 2012 Vess A2600 Series Architectural & Engineering Specifications Version: 1.2 Sep, 2012 www.promise.com Copyright 2012 Promise Technology, Inc. All Rights Reserved. No part of this document may be reproduced

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-16i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-001137-01 For a comprehensive list of changes to this document, see the Revision History.

More information

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017.

XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics. Document last updated: November 30, 2017. XenData SXL- 4200N Archive System: Getting Started & Library Operation Basics Document last updated: November 30, 2017 Getting Started The SXL-4200N Archive System consists of a XenData SX-250 Archive

More information

Dell EMC Storage MD1280 Enclosure Owner's Manual

Dell EMC Storage MD1280 Enclosure Owner's Manual Dell EMC Storage MD1280 Enclosure Owner's Manual Regulatory Model: SP-2584, E11J Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.

More information

Hardware Guide. EPIC Next Generation Firewall. USG6000 Unified Security Gateway V100R001. Give us a call:

Hardware Guide. EPIC Next Generation Firewall. USG6000 Unified Security Gateway V100R001. Give us a call: EPIC Next Generation Firewall USG6000 Unified Security Gateway V100R001 15333 Avenue of Science, Suite 100 San Diego, CA 92128 Give us a call: 1-855-881-2004 Send us an email: info@edgewave.com For more

More information

E-Series Site Preparation Guide

E-Series Site Preparation Guide E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...

More information

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems. DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3

More information

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number: A33606-PCI-01 SAS-2 Expander User Manual Version: C Document Number: 90-000186 A33606-PCI-01 SAS-2 Expander User Manual DOCUMENT 90-000186, VERSION C (1/15/2011) This document describes Astek s 36-port

More information

16-SLOT IN-BAND MANAGEMENT CHASSIS

16-SLOT IN-BAND MANAGEMENT CHASSIS FCM-CHS2-XX 16-SLOT IN-BAND MANAGEMENT CHASSIS User's Guide. Version 1.6 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Data Domain Systems Table 1. DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

McAfee Data Loss Prevention

McAfee Data Loss Prevention Hardware Guide Revision B McAfee Data Loss Prevention Models 4400, 5500, 6600 This guide describes the features and capabilities of McAfee Data Loss Prevention (McAfee DLP) appliances to help you to manage

More information

Intel IP Network Server NSI2U

Intel IP Network Server NSI2U Product Brief Intel IP Network Server NSI2U The Intel IP Network Server, an alternative to custom chassis for network security applications, raises the performance bar for IP network security products

More information

N3150 Installation and Setup Instructions

N3150 Installation and Setup Instructions IBM System Storage N350 Installation and Setup Instructions Covering the N350 model GC27-426-0 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-000

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide June 2017 215-11208_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

4170 POS System Installation Guide

4170 POS System Installation Guide 4170 POS System 4170 Installation Guide Thank you for selecting UTC RETAIL s innovative Model 4170 Point of Sale solution! This Installation Guide will help you efficiently install the 4170 POS. The document

More information

Veritas 5340 Appliance Product Description. NetBackup 5340 Appliance and Veritas Flex 5340 Appliance

Veritas 5340 Appliance Product Description. NetBackup 5340 Appliance and Veritas Flex 5340 Appliance Veritas 5340 Appliance Product Description NetBackup 5340 Appliance and Veritas Flex 5340 Appliance Veritas 5340 Appliance Product Description Last updated: 2019-03-15 Legal Notice Copyright 2018 Veritas

More information

Veritas Velocity 7330 Appliance Product Description. Release 1.2.6

Veritas Velocity 7330 Appliance Product Description. Release 1.2.6 Veritas Velocity 7330 Appliance Product Description Release 1.2.6 Veritas Velocity 7330 Appliance Product Description Release 1.2.6 Legal Notice Copyright 2017 Veritas Technologies LLC. All rights reserved.

More information

Installation and Maintenance Manual

Installation and Maintenance Manual Installation and Maintenance Manual Version 2.6 / NEXSAN 1445 St. Charles Drive, Thousand Oaks, CA 91320 p. 866.4.NEXSAN COPYRIGHT Copyright 2009 2012 Nexsan Corporation. All Rights Reserved. TRADEMARKS

More information

VIRTUAL EDGE PLATFORM 4600 Next Generation Access

VIRTUAL EDGE PLATFORM 4600 Next Generation Access VEP4600 Spec Sheet VIRTUAL EDGE PLATFORM 4600 Next Generation Access Purpose-built open ucpe platform to host VNFs (Virtual Networking Functions). Ideal access platform for SD-WAN. The VEP4600 is a Dell

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide Dell Networking S4810 Open Networking (ON) Getting Started Guide Regulatory Model: S4810 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your

More information

NEXSAN E-SERIES. Nexsan E60X /E60XV and Nexsan E48X /E48XV RAID Storage Expansion Units. FRU Removal and Replacement Guide

NEXSAN E-SERIES. Nexsan E60X /E60XV and Nexsan E48X /E48XV RAID Storage Expansion Units. FRU Removal and Replacement Guide NEXSAN E-SERIES E60X /E60XV and E48X /E48XV RAID Storage Expansion Units Part Number: P0450141 Rev: A NEXSAN 910 E Hamilton Ave, Campbell, CA 95008 p. 1.760.690.1111 Copyright 2010 2016. All Rights Reserved

More information

E-Series Hardware Cabling Guide

E-Series Hardware Cabling Guide E-Series Hardware Cabling Guide April 2018 215-11792_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 6 Cabling concepts and best practices... 7 Cabling concepts...

More information

Introducing the Cisco NAM 2220 Appliance

Introducing the Cisco NAM 2220 Appliance CHAPTER 1 This chapter provides an introduction to the Cisco NAM 2220 appliance and describes the appliance hardware, major components, and front- and rear-panel LED indicators, controls, and connectors.

More information

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide NEC Express5800/R120h-2M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9211-4i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-000852-01 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

HYPER-UNIFIED STORAGE. Nexsan Unity

HYPER-UNIFIED STORAGE. Nexsan Unity HYPER-UNIFIED STORAGE Nexsan Unity Network Configuration Guide Firmware Version: Unity 2.0 Nexsan 900 E. Campbell, CA 95008 p. 866.263.9726 www.nexsan.com Document release date: 1/19/2018, Rev. B Copyright

More information

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA)

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA) LSI SAS 9212-4i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA) User Guide Version 1.1 DB15-000853-01 For a comprehensive list of changes to this document, see the Revision History.

More information

Oracle Database Appliance X6-2S / X6-2M

Oracle Database Appliance X6-2S / X6-2M Oracle Database Appliance X6-2S / X6-2M The Oracle Database Appliance saves time and money by simplifying deployment, maintenance, and support of database solutions for organizations of every size. Optimized

More information

Oracle Database Appliance X6-2L

Oracle Database Appliance X6-2L Oracle Database Appliance X6-2L The Oracle Database Appliance saves time and money by simplifying deployment, maintenance, and support of database solutions for organizations of every size. Optimized for

More information

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents...

Read Me First. FUJITSU Storage ETERNUS CS800 S6. Table of Contents P3AM EN. ETERNUS CS800 S6 Manuals Package Contents... FUJITSU Storage ETERNUS CS800 S6 Read Me First Fujitsu would like to thank you for purchasing our FUJITSU Storage ETERNUS CS800 S6 (hereinafter referred to as "ETERNUS CS800 S6"). Read this document and

More information

Genesis HyperMDC 200D

Genesis HyperMDC 200D The Genesis HyperMDC 200D is a metadata cluster designed for ease-of-use and quick deployment. IPMI Control Dual Power Supplies Enhanced Metadata Uptime Storage Up to 1.3M IOPS and 5,500 MBps throughput

More information

VelaSync HIGH-SPEED TIME SERVER. Quick Reference Guide

VelaSync HIGH-SPEED TIME SERVER. Quick Reference Guide VelaSync HIGH-SPEED TIME SERVER Quick Reference Guide 1225-5000-0051 Rev. 4 March 2016 Table of Contents Introduction... 1 Specifications... 1 Safety Precautions... 2 Front Panel... 2 Rear Panel... 3 TimeKeeper...

More information

NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide NEC EXPRESS5800/R320a-E4 Configuration Guide Linux model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast

More information

CSM200 Expansion Tray

CSM200 Expansion Tray CSM200 Expansion Tray Initial Setup Guide for SANtricity users or VTL environments EC1718-1-E3, Third Edition Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation

More information

NEC Express5800/R120d-2M Configuration Guide

NEC Express5800/R120d-2M Configuration Guide NEC Express5800/R120d-2M Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

Symantec NetBackup 5030 Appliance Hardware Troubleshooting and Parts Replacement Guide

Symantec NetBackup 5030 Appliance Hardware Troubleshooting and Parts Replacement Guide Symantec NetBackup 5030 Appliance Hardware Troubleshooting and Parts Replacement Guide The software described in this book is furnished under a license agreement and may be used only in accordance with

More information

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter ClearCube FO-065-1200 series 12-Port Media Converter ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter User s Manual 1 ClearCube Connectivity Systems F6151 Media Converter

More information