System Display and Controller

Size: px
Start display at page:

Download "System Display and Controller"

Transcription

1 System Display and Controller

2 Contents Basic Navigation Menu Maps - MATE System Display and Controller Basic Setup. 2 MATE System Display and Controller Advanced Setup. 3 MATE System Display and Controller AGS Menu Inverter Setup Charge Controller Setup 8 FLEXnet DC Setup. 9-0 WARNING: SHOCK HAZARD Consult the MATE Owner s Manual for detailed information on safety and installation procedures Rev A.vsd\TOC\

3 The following pages are intended as a quick reference guide for the menu map of the MATE Series System Display and Controller. This document is for use with the products MATE and MATE2. It cannot be used with the MATE3. See the MATE Series Owner s Manual for detailed information about the menu structure, MATE features, and hot/soft key functions. See the inverter, charge controller, and DC monitor manuals for detailed information about specific features and functions that are controlled by the menus. AC IN LED AC IN Hot Key LCD Screen INV LED INV Hot Key Selection from Main Menu Main Screen choose device: FX MATE Main Menu Soft Keys Soft Key Color Code: Available menus Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. Select this option to proceed Adjusts the set points value BASIC NAVIGATION Soft Keys Device Selection Menu Device Menu Title(s) SETUP/FX Selects a function (e.g., ON, OFF, AUTO) Switches between devices on the ports of the Communications HUB Navigation colors AC IN Hot Key LCD Screen INV LED INV Hot Key Soft Keys Menu Item Setpoint or function for the Menu Item Port SETUP/FX/SEARCH------P0 6 SETUP/FX/SEARCH------P0 search sensitivity SETUP/FX/SEARCH search 6 sensitivity Navigation: Soft key functions will vary depending on the selected menu and are defined by the word above the key in the LCD. Indicates a -screen movement within a Menu. These are color coded according to their function or purpose. If accompanied by a dashed line, pressing that soft key will return the user to the location identified by the dashed line. This will vary depending on the devices in the system. To cycle through the devices connected to the HUB, press the <PORT> soft key Rev A.vsd\Menu Map Basics\ Page

4 Startup Screens Main Screen MAIN AC IN MAIN G'day Mate INV Setting up the MATE or MATE2 includes:. Setting the Clock (date and time) 2. Setting the screen contrast. 3. Setting the Glow time. 4. Setting how the Summary screens are displayed. 5. Setting communication options. 6. Setting Beep tone functions. SETUP choose device: FX MATE SETUP/MATE/PAGE mate code rev: 4..3 : CLOCK CNT GLOW PG2 SETUP/MATE/PAGE : PG SUMRY COMM PG3 Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. SETUP/MATE/PAGE : PG2 BEEP MAIN MATE (C)2009 OutBackPower Version Code a.a.a Serial #xxxxxxxx Screen EE b.bb Systems Searching for Devices FX Found Current Day Tu 0/0/09 INC SET DAY MONTH SETUP/MATE/CLOCK Tu /0/09 2:00:00P BACK DATE TIME Current Hour 2:00:00P INC SET HOUR 5 MIN SETUP/MATE/CNT contrast 30% BACK INC DEC SETUP/MATE/GLOW backlight controls BACK LEVEL MODE TIME SETUP/MATE/SUM/TYPE---- summary screen type BACK INC DEC SETUP/MATE/SUM summary control BACK TYPE DELAY ROLL Repolling SETUP/MATE/COMM Choose category: Searching for Devices BACK REPOLL PC DEBUG HUB Found SETUP/MATE/BEEP button beep tone ON BACK OFF ON Searching for Devices CC Found Searching for Devices DC Found Searching for Devices HUB Found Port Assignment > FX 2>CC 3> DC 4> 5> 6> 7> 8> 9> 0> 2M> Main Screen MAIN Current Month Tu 0/0/09 INC SET MONTH 2 DATE Current Date Tu 0/0/09 INC SET DATE 3 YEAR Current Year Tu 0/0/09 INC DEC YEAR YEAR 4 DONE Current Minute 2:00:00P 6 INC DEC RESET MIN MIN SEC DONE Setpoints (Current Day): Monday through Sunday Setpoints (Current Month): 0 through 2 Setpoints (Current Date): 0 through 3 Setpoints (Current Year): 09 through xx Setpoints (Current Hour): 0-2AM or 0-2PM Setpoints (Reset Sec): Resets seconds to 00 SETUP/MATE/GLOW/LEVEL backlight 00% BACK INC DEC SETUP/MATE/GLOW/MODE current code: AUTO BACK OFF AUTO ON SETUP/MATE/GLOW/TIME glow Off 5 mins time BACK INC DEC Setpoints: None Roll: rotates between devices FX Only CC Only DC Only DC Simple SETUP/MATE/SUM/DELAY- Sum screen 9 mins Delay time BACK INC DEC SETUP/MATE/SUM/DELAY- Sum screen 0 seconds Roll rate BACK INC DEC Port Assignment > FX 2>CC 3> DC 4> 5> 6> 7> 8> 9> 0> 2M> Varies depending on attached devices. Automatically returns to the Main Screen. SETUP/MATE/COMM/PC PC communications: OFF BACK OFF ON SETUP/MATE/COMM Comm errors: BACK VIEW RSET Viewing Comm Errors 00:000 0:000 02:000 03:000 04:025 05:00 06:00 07:00 08:00 09:00 0:00 2M:00 After Resetting Comm Errors 00:000 0:000 02:000 03:000 04:000 05:000 06:000 07:000 08:000 09:000 0:000 2M: Rev A.vsd\MATE Basic Setup\ Page 2

5 (continued) Resetting the MATE2 to Factory Defaults Charge Controller and FLEXnet DC Menus Changing more detailed operating parameters requires access to the Advanced Setup Menu. Accessing the Advanced Menu: Page Page 2 Page 3 ADV/MATE/PAGE HBX GRIDUSE AGS PG2 The AGS Menu is shown on the next page. ADV/MATE/PAGE : PG DEFAULTS PG3 ADV/MATE/PAGE advanced charger float control PG2 CC FN-DC PG4 ADV/MATE/HBX hbx-use 24.0 Vdc grid set point DOWN ADV INC DEC ADV/MATE/GRIDUSE griduse enable: OFF DOWN ADV OFF ON ADV/MATE/DEFAULT reset MATE to factory default RESET NO ADV/MATE/PG3/CC enable CC float coordination: Yes PG3 YES NO ADV MATE ADV/SETTINGS/WARNING changes made could adversely affect system performance ADV/MATE/HBX hbx-use.0 hrs grid delay INC DEC ADV/MATE/GRIDUSE weekday 2:00A griduse start time CHANGE WEEKDAY GRIDUSE START WEEKDAY GRIDUSE START ADV/MATE/DEFAULT Are you sure? YES NO ADV/MATE/PG3/FN-DC enable FN-DC charge termination: Yes PG3 YES NO ADV ADV/PASSOWRD ADV/MATE/HBX hbx-drop 26.0 Vdc grid set point INC DEC ADV/MATE/GRIDUSE weekday 2:00A griduse stop time CHANGE WEEKDAY GRIDUSE S WEEKDAY GRIDUSE S A B B A. Press the <INC> soft key until 4 is displayed on the LCD. 2. Press the <ENTER> soft key to accept the password and move forward to the Device Selection Menu. ADV/PASSOWRD ADV choose device FX CC DC MATE ADV/MATE/HBX hbx-drop.0 hrs grid delay INC DEC ADV/MATE/HBX ac input USE control CHANGE ADV/MATE/HBX ac input USE control DROP USE HBX DONE ADV/MATE/HBX end of hbx menu UP ADV ADV/MATE/GRIDUSE weekend 2:00A griduse start time CHANGE ADV/MATE/GRIDUSE weekend 2:00A griduse stop time CHANGE ADV/MATE/GRIDUSE end of griduse menu UP ADV WEEKEND GRIDUSE START WEEKEND GRIDUSE S WEEKEND GRIDUSE START WEEKEND GRIDUSE S Page 4 ADV/MATE/PG FN-DC advanced grid tie authority PG3 MODE ADV MAIN ADV/MATE/AGS/PG4/MODE-- FN-DC enable disabled PG4 IN DEC ADV Press and hold the 2 left soft keys at the same time. Release when the Main screen appears Rev A.vsd\MATE ADV Setup\ Page 3

6 (continued) ADV/MATE/PAGE HBX GRIDUSE AGS PG2 ADV/MATE/AGS : QUIET VOLT SETUP TIME START PG2 Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. Continued on the next page... ADV/MATE/AGS/SETUP ags port: DOWN AGS INC DEC ADV/MATE/AGS/QUIETTIME-- weekday 2:00A quiet time start CHANGE WEEKDAY QT START WEEKDAY QT START ADV/MATE/AGS/VSTART----- volt start 24.4 Vdc 24 hr setting DOWN AGS INC DEC MATE ADV/MATE/AGS/SETUP ags enabled: No NO YES ADV/MATE/AGS/QUIETTIME-- weekday 2:00A quiet time stop CHANGE WEEKDAY QT S WEEKDAY QT S ADV/MATE/AGS/VSTART----- volt start 23.6 Vdc 2 hr setting INC DEC ADV/MATE/AGS/SETUP ags control: MAN-OFF CHANGE GEN START CONTROL currently: MAN-OFF OFF AUTO ON OK ADV/MATE/AGS/VSTART----- volt start 22.0 Vdc 2 min setting INC DEC ADV/MATE/AGS/SETP dc genset: No NO YES ADV/MATE/AGS/SETUP Vdc genstop 38.0 Vdc INC DEC ADV/MATE/AGS/SETUP ags fault time 7 minutes INC DEC ADV/MATE/AGS/SETUP cool down time 0 minutes INC DEC ADV/MATE/AGS/SETUP warm up time 0 minutes INC DEC ADV/MATE/AGS/SETP end of AGS Setup menu UP AGS ADV/MATE/AGS/QUIETTIME-- weekend 2:00A quiet time start CHANGE ADV/MATE/AGS/QUIETTIME-- weekend 2:00A quiet time stop CHANGE ADV/MATE/AGE/QUIETTIME-- end of quiet time menu UP AGS WEEKEND QT START WEEKEND QT S WEEKEND QT START WEEKEND QT S ADV/MATE/AGE/QT end of VOLTAGE START menu UP AGS Rev A.vsd\MATE ADV Setup 2\ Page 4

7 (continued) Advanced Setup Menu (Continued) ADV/MATE/PAGE HBX GRIDUSE AGS PG2 ADV/MATE/AGS : QUIET VOLT SETUP TIME START PG2 ADV/MATE/AGS/PAGE %soc PG2 START TIMERS PG4 ADV/MATE/AGS/PAGE : PG3 EXERCISE ADV Continued from the previous page. ADV/MATE/AGS/PAGE LOAD MUST PG START RUN PG3 ADV/MATE/AGS/%SOC %SOC start 0% DOWN AGS INC DEC ADV/MATE/AGS/%SOC %SOC stop 90% INC DEC ags state 0 DOWN AGS agsgenfault 0 ADV/MATE/AGS/EX ex start day --- DOWN AGS INC DEC ADV/MATE/AGS/EX ex start time 2:00A MATE ADV/MATE/AGS/LS load start 0 kw DOWN AGS INC DEC ADV/MATE/AGS/MR weekday 2:00 A must run start time DOWN AGS CHANGE WEEKDAY MR START WEEKDAY MR START ADV/MATE/AGS/FULLCHG--- charge to 00% full every 5 days INC DEC 24 hr 440 min vs time INC DEC ADV/MATE/AGS/EX ex period 5 min ADV/MATE/AGS/LS load start min delay INC DEC ADV/MATE/AGS/MR weekday 2:00 A must run stop time CHANGE WEEKDAY MR S WEEKDAY MR S ADV/MATE/AGS/%SOC end of %SOC START Menu UP AGS 2 hr vs time 20 min INC DEC ADV/MATE/AGS/ES end of exercise Menu UP AGS ADV/MATE/AGS/LS load stop 0 kw INC DEC ADV/MATE/AGS/MR weekend 2:00 A must run start time CHANGE WEEKEND MR START WEEKEND MR START 2 min 2 min vs time ADV/MATE/AGS/LS load stop min delay INC DEC ADV/MATE/AGS/MR weekend 2:00 A must run stop time CHANGE WEEKEND MR S WEEKEND MR S lsstart timer 0 min Vdcstop timer 0 min ADV/MATE/AGE/LS end of LOAD START menu UP AGS ADV/MATE/AGE/MR end of MUST RUN menu UP AGS lsstop timer 0 min exstop timer 0 min end of TIMERS Menu UP AGS Rev A.vsd\MATE ADV Setup 3\ Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. Page 5

8 Setting up the basic Inverter functions includes:. Selecting the AC input (Grid or Gen). 2. Setting the Search function. Main Screen SETUP choose device: FX MATE SETUP/FX SRCH INPUT Changing more detailed operating parameters requires access to the Advanced Setup Menu. Accessing the Advanced Menu: ADV/SETTINGS/WARNING changes made could adversely affect system performance ADV/PASSOWRD A ADV/FX/INVERTER-----P0 search 6 sensitivity ADV/FX/INVERTER-----P0 search 8 pulse length ADV/FX/INVERTER-----P0 search 8 cycles pulse length Advanced Menu for Inverter (Page of 3) ADV/FX/PAGE ADV INV CHRG PG2 ADV/FX/INVERTER reset FX to factory defaults DOWN MORE Resetting the Inverter to Factory Defaults ADV/FX/INVERTER------P0 choose fx port then press next EXIT PORT NEXT NOTE: The values shown in this illustration will vary depending on the model of inverter. Continued on next page. charger 2.0Aac limit charger 2.0 Aac limit absorb 28.8 Vdc set point INVERTER SETUP/FX/SEARCH------P0 search 6 sensitivity SETUP/FX/SEARCH------P0 search 8 cycles pulse length SETUP/FX/INPUT P0 ac transfer control DOWN GRID GEN PORT SETUP/FX/INPUT Ac/grid 60.0 aac limit Setpoints: Grid Generator A B. Press the <INC> soft key until 4 is displayed on the LCD. 2. Press the <ENTER> soft key to accept the password and move forward to the Device Selection Menu. ADV/PASSOWRD ADV/FX/INVERTER------P0 search 60 cycles pulse spacing ADV/FX/INVERTER------P0 low battery 2.0 Vdc cutout set point ADV/FX/INVERTER------P0 press button Ready EXIT 2 ADV/FX/INVERTER------P0 press button 2 Ready EXIT 2 absorb.0 hrs time limit float 27.2 Vdc set point refloat 25.0 Vdc set point equalize 28.8 Vdc set point SETUP/FX/SEARCH------P0 search 60 cycles pulse spacing SETUP/FX/INPUT Ac2/gen 30.0 aac limit B ADV choose device FX CC DC MATE ADV/FX/INVERTER------P0 low battery 25.0 Vdc cutin set point ADV/FX/INVERTER------P0 press button 2 Done EXIT 2 float.0 hrs time limit equalize.0 hrs time limit SETUP/FX/SEARCH search setup completed SETUP MAIN SETUP/FX/INPUT Input setup completed SETUP MAIN ADV/FX/INVERTER------P0 adjust 20 Vac output voltage ADV/FX/INVERTER inverter programming completed ADV MAIN Main Screen charger programming completed ADV MAIN Rev A.vsd\INV Setup\ Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. Page 6

9 (continued) Advanced Inverter Setup Menu (continued) Continued from previous page. Page ADV/FX/PAGE ADV INV CHRG PG2 Page 3 ADV/FX/PAGE P0 PG2 AUX STACK PG4 Page 2 ADV/FX/PAGE P0 ADV GRID GEN PG3 aux output AUTO control stack -2PH Master phase Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. NOTE: The values shown in this illustration will vary depending on the model of inverter. ADV/FX/GRID P0 ac /grid 08 Vac lower limit ADV/FX/GEN P0 gen input 00.5 min connect delay aux output cool fan function stack Classic Slave phase Page 4 ADV/FX/GRID P0 ac /grid 40 Vac upper limit ADV/FX/GRID P0 ac /grid 48.0 Aac input limit ADV/FX/GEN P0 ac 2/gen 08 Vac lower limit ADV/FX/GEN P0 ac 2/gen 40.0 Aac upper limit genalert 22.0 Vdc on setpoint genalert 4 min on delay stack OB Slave L phase stack OB Slave L2 phase ADV/FX/SELL P0 sell re 23.6 Vdc volts ADV/FX/PAGE P0 PG3 SELL CAL MAIN ADV/FX/CALIBRATE-----P0 Vac input 20 vac adjustment INVERTER ADV/FX/GRID P0 ac /grid 6 cycles transfer delay ADV/FX/GEN P0 ac 2/gen 48.0 Aac input limit genalert 28.0 Vdc off set point vent fan off 5 min period stack 3PH Master phase ADV/FX/SELL P0 grid tie IEEE window DOWN IEEE USER PORT ADV/FX/CALIBRATE-----P0 Vac output 20 Vac adjustment ADV/FX/GRID P0 grid programming completed ADV MAIN ADV/FX/GEN P0 ac 2/gen 60 cycles transfer delay genalert 9 min off delay diversion 29.2 Vdc on set point stack 3 PH Slave phase power save level 0 slave adjust only ADV/FX/SELL P0 grid tie GRIDTIE authority DOWN IEEE USER PORT ADV/FX/CALIBRATE-----P0 battery Vdc 25.4 Vdc adjustment ADV/FX/GEN P0 ac 2/gen ON support loadshed 22.0 Vdc off set point diversion 30 sec off delay power save level 0 master adjust only stacking setup completed ADV MAIN ADV/FX/SELL P0 selling setup completed ADV MAIN ADV/FX/CALIBRATE-----P0 calibration setup completed ADV MAIN ADV/FX/GEN P0 gen programming completed ADV MAIN vent fan 26.0 Vdc on set point aux output setup completed ADV MAIN Rev A.vsd\INV Setup 2\ Page 7

10 Changing more detailed operating parameters requires access to the Advanced Setup Menu. Accessing the Advanced Menu: Advanced Menu for the FLEXmax Charge Controller (Page of 2) ADV/CC/PAGE ADV CHGR CCADV PG2 Advanced Menu for the FLEXmax Charge Controller (Page 2 of 2) ADV/CC/PAGE P02 PG EQ AUX MAIN ADV/SETTINGS/WARNING changes made could adversely affect system performance ADV/CC/CHGR P02 output current 80.0 A limit snooze mode <0.6 AMP Mpp range limit %VOC maximum 90% RTS compensation wide ADV/CC/EQ P02 eq voltage 28.8 VOC DOWN INC SETUP ADV ADV/CC/AUX P02 vent fan DOWN INC SET PORT ADV/PASSWORD ADV/CC/CHRG P02 absorb voltage 28.8 V wakeup mode VOC change 3.0 V MPP range limit % VOC minimum /2 RTS comp limit upper limit 28.2 Vdc ADV/CC/EQ P02 eq time hours DOWN INC SETUP ADV ADV/CC/AUX P02 aux control OFF DOWN ON OFF PORT A A B B. Press the <INC> soft key until 4 is displayed on the LCD. 2. Press the <ENTER> soft key to accept the password and move forward to the Device Selection Menu. ADV/PASSOWRD ADV choose device FX CC DC MATE ADV/CC/CHRG P02 float voltage 27.2 V ADV/FX/CHRG P02 end charger menu ADV MAIN wakeup mode time 5 minutes MPPT mode auto track grid tie mode nongt absorb time.0 hours absorb end amps 0A rebulk voltage 24.8 Vdc RTS comp limit lower limit 26.4 Vdc auto restart mode 0 AUX output polarity active ADV/CC/EQ P02 eq auto eq interval 0 days DOWN INC SETUP ADV ADV/CC/EQ P02 end CC eq menu ADV MAIN ADV/CC/aux P02 end of menu ADV MAIN CHARGE CONTROLLER park MPP 77.0% vbatt calibration 29.3 Vdc 0.0 Vdc Reset CC to factory defaults? DOWN YES NO PORT Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. end CC advanced menu ADV MAIN Rev A.vsd\CC Setup on MATE\ Page 8

11 STATUS/DC/PAGE Main Screen MAIN State-of-Charge Screen E F Battery Discharging State of Charge 00% Main Screen STATUS choose device: FX CC DC MAIN STATUS/DC/PAGE STATS METER SHUNT BATT PG2 Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. NOTE: The values shown in this illustration will vary depending on the model of inverter. PG AUX MAIN STATUS/DC/AUX aux control manual DOWN STATUS STATUS/DC/PAGE aux relay state: OFF UP STATUS Summary Screen # DC Now 25.4V 00% IN 0.4A 0.00kW OUT.6A 0.040kW BAT -.2A kW A: 0. A 0.00 kw B: 0.0 A kw C: 0.0 A kw DOWN STATUS STATUS/DC/SHUNT A max removed amps 0.9 RESET total days at 00% 0.5 RESET These screens are informational only. No changes can be made from this location in the Menu Map. Summary Screen #2 DC Today minsoc 97% In 247AH 2.84kWH Out 240AH 2.50kWH Bat 7AH 0.34kWH Summary Screen #3 FX Total 25.4V 97% Inverting 0.000kW AC Loads 0.000kW Buying $ 0.000kW Summary Screen #4 DC BAT 25.4V 00% Bat -0.3A -0.00kW Net 0.4AH 0.00kWH Days Since Full. Press this soft key to proceed. This screen will also automatically move forward after a userdefined period of time. A: - Ah 0.00 kwh B: 0 Ah kwh C: 0 Ah kwh METER/DC/SHUNT A removed 2 AH 0.6 kwh METER/DC/SHUNT A charged 2 AH 0.6 kwh METER/DC/SHUNT B removed 0 AH 0 kwh METER/DC/SHUNT B charged 2 AH 0.6 kwh METER/DC/SHUNT C removed 0 AH 0 kwh METER/DC/SHUNT C charged 0 AH 0.00 kwh METER/FN/METER DC firmware revision /040 METER/FN/METER end of meter menu UP STATUS STATUS/DC/SHUNT A max removed kwatts 0.00 RESET STATUS/DC/SHUNT A amps 0. RESET STATUS/DC/SHUNT A kwatts 0.29 RESET STATUS/DC/SHUNT B max removed amps 0 RESET STATUS/DC/SHUNT B amps 30.2 RESET STATUS/DC/SHUNT B amps 39.8 RESET STATUS/DC/SHUNT B kwatts RESET STATUS/DC/SHUNT C max removed amps 0 RESET STATUS/DC/SHUNT C amps 30.2 RESET STATUS/DC/SHUNT C amps 39.8 RESET STATUS/DC/SHUNT C kwatts RESET STATUS/DC/SHUNT end of shunt status menu UP STATUS days since charge parameters met 5.9 battery min today 24.8 Vdc RESET battery max today 25.4 Vdc RESET temp comp d batt setpoint 28.4 Vdc system battery temperature 29 C cycle charge factor 78% cycle kwhr charge efficiency 65% lifetime kah removed 5 RESET end of battery status menu UP STATUS FLEXnet DC Rev A.vsd\FNDC\ Page 9

12 (continued) Accessing the Advanced Menu: ADV/DC/PAGE ADV/DC/PG2 ADV/DC/PG P03 ADV BAT SHUNT PG2 PG CHARGE AUX PG3 PG2 RESET CLR MAIN ADV/SETTINGS/WARNING changes made could adversely affect system performance ADV/DC/BAT P03 battery capacity 0 amphours INC DEC ADV ADV/DC/SHUNT P03 shunt A mode enabled DOWN EN DIS ADV/DC/CHARGE return amps 0.4 currently MAN-OFF DOWN OFF AUTO ON ADV/DC/RESET P03 reset DC to factory defaults? NO YES ADV/DC/CLEAR clear data log memory? YES NO ADV/PASSWORD ADV/DC/SHUNT P03 shunt B mode enabled ADV/DC/CHARGE battery voltage 26.0 high volts 29.0 Vdc DOWN EN DIS ADV/PASSWORD ADV choose device ADV/DC/SHUNT P03 shunt C mode disabled DOWN EN DIS ADV/DC/CHARGE parameters met time minutes low volts 22.0 Vdc FX CC DC MATE ADV/DC/SHUNT P03 shunt setup complete ADV MAIN ADV/DC/CHARGE charge factor 93% SOC high 90% low set point delay minutes ADV/DC/CHARGE charge parameters complete ADV MAIN SOC low 59% invert logic YES DOWN YES NO Press and hold the 2 left soft keys at the same time. Release when the Main screen appears. NOTE: The values shown in this illustration will vary depending on the model of inverter. high set point delay minutes aux parameters complete ADV MAIN FLEXnet DC Rev A.vsd\FNDC Adv\ Page 0

13 About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, accessories, and assembled systems. Contact Information Telephone: (Main) (Technical Support) (Fax) Mailing Address: OutBack Power Technologies Sales & Marketing th Street N.E nd Street NE Arlington, WA USA Arlington, WA USA Web Site: Disclaimer Support@outbackpower.com UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER TECHNOLOGIES: (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK. Warranty Summary OutBack Power Technologies warrants that the products it manufactures will be free from defects in materials and workmanship for a period of five (5) years subject to the conditions set forth in the warranty detail, found in the product manual. OutBack Power Technologies cannot be responsible for system failure, damages, or injury resulting from improper installation of their products. Notice of Copyright MATE Series Overview January 202 by OutBack Power Technologies. All Rights Reserved. Trademarks OutBack Power is a registered trademark of OutBack Power Technologies. Date and Revision January 202, Revision A Part Number Rev A

14 30099

Descripción General del MATE y MATE2. Sistema de Visualización y Control

Descripción General del MATE y MATE2. Sistema de Visualización y Control Descripción General del MATE y MATE2 Sistema de Visualización y Control Contenido Conceptos Básicos..... 1 Mapa de menús - Configuración Básica.... 2 Configuración Avanzado...... 3 Arranque Automático

More information

FX AND VFX SERIES INVERTER/CHARGER Programing Manual

FX AND VFX SERIES INVERTER/CHARGER Programing Manual FX AND VFX SERIES INVERTER/CHARGER Programing Manual Warranty Summary Dear OutBack Customer, Thank you for your purchase of OutBack products. We make every effort to assure our power conversion products

More information

Owner s Manual Revision 4.01 Option 1

Owner s Manual Revision 4.01 Option 1 Owner s Manual Revision 4.01 Option 1 Special Version of the SW series Inverter / Charger for Motor Coach Applications Part # 2031-7 (Supplement to Normal Manual) Effective Date: April 17, 1996 Trace Engineering

More information

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater For additional information contact matedev@outbackpower.com Page 1 of 14 Revision History Revision 2.0:

More information

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1) User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com

More information

MATE3 System Display and Controller Owner s Manual

MATE3 System Display and Controller Owner s Manual MATE3 System Display and Controller Owner s Manual About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave

More information

FLEXmax 100 with ICS Plus

FLEXmax 100 with ICS Plus FLEXmax 100 with ICS Plus Objective of the application note This application note will provide some supplemental information on how to integrate the FLEXmax 100 (FM100) with the Rapid Shutdown features

More information

WattPlot. WattPlot PRO USER S GUIDE. and. Monitoring and Diagnostics Program for Renewable Energy Devices from OutBack Power Systems. version 4.

WattPlot. WattPlot PRO USER S GUIDE. and. Monitoring and Diagnostics Program for Renewable Energy Devices from OutBack Power Systems. version 4. WattPlot and WattPlot PRO version 4.2 Monitoring and Diagnostics Program for Renewable Energy Devices from OutBack Power Systems USER S GUIDE September, 2008 built by intel act Copyright 2006-08, Andrew

More information

MATE3 System Display and Controller Owner s Manual

MATE3 System Display and Controller Owner s Manual MATE3 System Display and Controller Owner s Manual About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave

More information

MATE3 System Display and Controller Owner s Manual

MATE3 System Display and Controller Owner s Manual MATE3 System Display and Controller Owner s Manual About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true sine wave

More information

Technical Note: XW/Conext XW+

Technical Note: XW/Conext XW+ U Technical Note: XW/Conext XW+ Compatibility 976-0316-01-01 Rev B March 2015 Introduction The goal of this technical note is to provide the reader with adequate knowledge to plan and take considerations

More information

COM. Warning MATE MICRO. Esc OK. OutBack Mate Micro User s Manual

COM. Warning MATE MICRO. Esc OK. OutBack Mate Micro User s Manual Warning COM MATE MICRO Esc OK OutBack Mate Micro User s Manual About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. Our products include true

More information

Modbus Map: Automatic Generator Start (AGS) Device

Modbus Map: Automatic Generator Start (AGS) Device Modbus Map: Automatic Start (AGS) Device 503-0247-01-01 Revision A.1 UNINTENDED OPERATION WARNING The use of this product with Modbus communications requires expertise in the design, operation, and programming

More information

Hardware definition of comm system:

Hardware definition of comm system: Filename = Magnum Networking Communications Protocol.XLS 7-May-03 Update 10-Oct-03 Update 23-May-05 add 0% charge rate and 250 VAC Dropout for ac disconnect for EMS support Update 28 March 2006 for new

More information

Version 3.00 User s Guide

Version 3.00 User s Guide Xantrex TM XW Config Version 3.00 User s Guide www.schneider-electric.com Xantrex XW Config Version 3.00 User s Guide www.schneider-electric.com Copyright and Contact Copyright 2012 Schneider Electric.

More information

Using the AUX Port on the Conext XW+ to Connect to a Generator or the Grid

Using the AUX Port on the Conext XW+ to Connect to a Generator or the Grid Using the AUX Port on the Conext XW+ to Connect to a Generator or the Grid solar.schneider-electric.com 976-0324-01-01/A July 2015 Application Note EXCLUSION FOR DOCUMENTATION UNLESS SPECIFICALLY AGREED

More information

FLEXmax 100 Charge Controller. Owner s Manual

FLEXmax 100 Charge Controller. Owner s Manual FLEXmax 100 Charge Controller Owner s Manual About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. OutBack products include true sine wave inverter/chargers,

More information

METERING/DISPLAY MANUAL

METERING/DISPLAY MANUAL METERING/DISPLAY MANUAL 175W - 750W SINGLE PHASE Series LV EMERGENCY LIGHTING CENTRAL INVERTER Myers Power Products, Inc. 44 South Commerce Way, Bethlehem, PA 18017 1-800-526-5088 (610) 868-3500 Fax: (610)

More information

Infinisolar V Hybrid-On Grid Inverter with Energy Storage

Infinisolar V Hybrid-On Grid Inverter with Energy Storage Infinisolar V Hybrid-On Grid Inverter with Energy Storage Pure sine wave output Self-consumption and Feed-in to the grid Programmable supply priority for PV, Battery or Grid User-adjustable charging current

More information

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs

INSTRUCTION MANUAL. Model Dual Input RTD Thermometer. Measures two temperatures simultaneously. Dual RTD probe inputs INSTRUCTION MANUAL Model 421504 Dual Input RTD Thermometer Measures two temperatures simultaneously Dual RTD probe inputs Clock and Elapsed Timer functions Special functions include Data Hold, MIN/MAX/AVG,

More information

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety

More information

TC100 Precision Thermocouple Calibrator

TC100 Precision Thermocouple Calibrator TC100 Precision Thermocouple Calibrator Table of Contents 1. Introduction.....................1 2. Accessories....................5 3. Set-Up Basic/Advanced...........5 4. Operating Procedure.............6

More information

Conext CL-60 Inverter Firmware Upgrade Process

Conext CL-60 Inverter Firmware Upgrade Process Conext CL-60 Inverter Firmware Upgrade Process http://solar.schneider-electric.com 976-0380-01-01/B August 2017 Application Note EXCLUSION FOR DOCUMENTATION UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER

More information

P4472 Save A Watt HD Operation Manual

P4472 Save A Watt HD Operation Manual P4472 Save A Watt HD Operation Manual Thank you for purchasing the P4472 Save A Watt HD. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,

More information

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

Contents 1 Warnings, Cautions, and Notes Description Features... 1

Contents 1 Warnings, Cautions, and Notes Description Features... 1 EnCell Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 1 3 Features... 1 3.1 STANDARD FEATURES... 1 3.2 FRONT PANEL FEATURES... 2 3.2.1 Display... 2 3.2.2 OK LED... 2 3.2.3 FAULT LED...

More information

Modbus Map: MPPT60 Device

Modbus Map: MPPT60 Device 503-0248-01-01 Revision A.1 UNINTENDED OPERATION WARNING The use of this product with Modbus communications requires expertise in the design, operation, and programming of the device. Only qualified persons

More information

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual PG5 Digital Pressure Gauge DOC. 9003264 Rev. A1 3/10 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com PG5

More information

User s Guide. 600A AC Clamp Meter. Model 38387

User s Guide. 600A AC Clamp Meter. Model 38387 User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

FW-SP-ACA FW-SP-250 FW-SP-R

FW-SP-ACA FW-SP-250 FW-SP-R Surge Protector FW-SP-ACA FW-SP-250 FW-SP-R User s Guide Includes Mounting and Installation About OutBack Power Systems OutBack Power Systems is a leader in advanced energy conversion technology. Our products

More information

Radian Series Inverter/Charger GS4048A GS8048A. Installation Manual

Radian Series Inverter/Charger GS4048A GS8048A. Installation Manual Radian Series Inverter/Charger GS4048A GS8048A Installation Manual About OutBack Power Technologies OutBack Power Technologies is a leader in advanced energy conversion technology. OutBack products include

More information

Integrated Stepper Drive & Motor

Integrated Stepper Drive & Motor SMD23 Integrated Stepper Drive & Motor Manual #: 940-0S050 User Manual AMCI Motion Control Products Important User Information The products and application data described in this manual are useful in a

More information

Generac/Guardian Residential Standby Generators

Generac/Guardian Residential Standby Generators Generac/Guardian Residential Standby Generators Procedure to Enable 2-Wire Remote Start Document Number: BGS-GRC-RS-1 Date: 15 Mar 2010 Revision: F 603.787.2317 info@begreensolar.com Page 1 Revision Original

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

Automatic start of a generator

Automatic start of a generator AN--V.1.3.3-10 STUDER INNOTEC SA Application Note Automatic start of a generator General description This application note will help you to set your Xtender for an automatic start of a generator as per

More information

NX8 Pocket Toner Users Guide

NX8 Pocket Toner Users Guide NX8 Pocket Toner Users Guide The NX8 Pocket Toner lets you quickly do tests for continuity, short circuits, ac and dc voltage, and 50 Ω or 75 Ω termination. The standard adapters let you use the toner

More information

SENS Setup Utility CONFIGURE CHARGERS/SYSTEMS WITH CUSTOM SETTINGS. Operation Manual

SENS Setup Utility CONFIGURE CHARGERS/SYSTEMS WITH CUSTOM SETTINGS. Operation Manual SENS Setup Utility For SENS MicroGenius and MicroCab TM Products CONFIGURE CHARGERS/SYSTEMS WITH CUSTOM SETTINGS Operation Manual SENS Part Number: 101325 Document Revision: F DCN Number: 107593 Date:

More information

Evolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033

Evolution Variable Output. With Override Pot. Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL 35033 Evolution Variable Output With Override Pot, Inc. 1733 Co Rd 68 PO Box 99 Bremen, AL 3033 Part No. 4801318 Rev 703 Owners Manual Evolution Variable Output Table of Contents Section Title Page 1. Warranty...3

More information

New Products. MidNite Solar Inc.

New Products. MidNite Solar Inc. New Products MidNite Solar Inc. We make stuff!!! Vaporware- Stuff that doesn t yet exist The MidNite engineering department consists of 15 engineers and technicians The best I have ever worked with -Robin

More information

Model P4470 Save A Watt Operation Manual

Model P4470 Save A Watt Operation Manual Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,

More information

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10 AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual PG-5 Full Access DOC. 9003384 Rev. A1 3/10 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com PG5 Rev.

More information

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction User's Guide Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model 382280 382280 Introduction Congratulations on your purchase of the Extech 382280 Programmable DC Power Supply. This 200 watt

More information

Power Solutions Catalogue

Power Solutions Catalogue Power Solutions Catalogue CONTENTS Uninterrupted Power Systems (UPS) T-4101 Series Range: 1-10kVA, Single Phase UPS (Transformer-less) 02 T-4101A Series Range: 3-10kVA, Single Phase UPS (Transformer-less)

More information

Modbus Map: Conext MPPT Device

Modbus Map: Conext MPPT Device Modbus Map: Conext MPPT 60 150 Device 503-0248-01-01 Revision A.3 UNINTENDED OPERATION WARNING The use of this product with Modbus communications requires expertise in the design, operation, and programming

More information

Datalogging ph Meter

Datalogging ph Meter Specifications Range Resolution Accuracy ph 0.00 ~ 14.00 ph 0.01 ph ±0.02 ph mv -999.9 ~ 999.9mV 0.1 mv ±0.2 mv @ -99.9 ~ 99.9mV ±2 mv @ other ranges Temperature -23 ~ 176 F (-5 ~ 80 C) 0.1 F( 0.1 C) Compensation

More information

User's Guide. Model High Precision Quad Output DC Power Supply

User's Guide. Model High Precision Quad Output DC Power Supply User's Guide Model 382270 High Precision Quad Output DC Power Supply Introduction Congratulations on your purchase of the Extech 382270 DC Power Supply. The Model 382270 can be used for many applications

More information

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc

Quick Start Guide. ELPRO 105U-L Wireless I/O Receiver Unit. man_105u-l-r_quickstart_v1-8.doc Quick Start Guide ELPRO 105UL Wireless I/O Receiver Unit man_105ulr_quickstart_v18.doc ELPRO 105UL Wireless I/O Receiver Unit Quick Start Guide About this document This document is the ELPRO 105UL Wireless

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

Please take serious note of the following warnings:

Please take serious note of the following warnings: TPDIN-SC48-20 MPPT Solar Controller with Passive PoE Switch Wireless Base Stations and Client Devices Surveillance Cameras Remote Control Remote Lighting Off Grid Electronics Congratulations! on your purchase

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL DT-118B MTP INSTRUCTION MANUAL Pocket Autoranging Digital Multimeter 3 in 1 Model MTP-1025 Auto Ran ging DMM Hz% A OFF V AU TO PO WER OFF MTP Instruments Table of Contents Introduction Page 1 Features

More information

Application Note on Modifying Disconnect Settings for Xantrex GT Series Single Phase Inverters and Conext TX Series Inverters

Application Note on Modifying Disconnect Settings for Xantrex GT Series Single Phase Inverters and Conext TX Series Inverters Application Note on Modifying Disconnect Settings for Xantrex GT Series Single Phase Inverters and Conext TX Series Inverters 976-0312-01-01 Revision A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

REMOTE METER USER MANUAL KAMPPTRC

REMOTE METER USER MANUAL KAMPPTRC REMOTE METER USER MANUAL K A M P P T R C KAMPPTRC 1. PRODUCT FEATURES 1) LCD screen. 2) Can display up to 10 parameters and states. 3) Has a low power consumption with BLE4.0 feature for strong communication

More information

REMOTE METER. Model: MT50 INSTRUCTION MANUAL

REMOTE METER. Model: MT50 INSTRUCTION MANUAL REMOTE METER Model: MT50 INSTRUCTION MANUAL For use with solar charge controllers PU series, LS series, VS series, PTR series, Tracer MPPT series and other compatible controllers Remote Meter MT50 Please

More information

Plus-X AC-8. User Guide

Plus-X AC-8. User Guide Plus-X AC-8 User Guide Table of Contents Introduction... 1 Network Requirements... 1 Setup and Configuration... 1 Operation... 5 Uploading Firmware... 7 Getting Help... 7 Warranty... 7 Appendix A: Specifications...

More information

DCM Digital Control Modules

DCM Digital Control Modules DCM Digital Control Modules TECHNICAL MANUAL Version 1.2 November 2011 Safety Precautions Caution Read Instructions: Read and understand all safety and operating instructions before using the equipment.

More information

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT30KX Highlights On-line double-conversion topology, VFI operation

More information

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1 POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.

More information

User's Guide. Model Laser Photo Tachometer

User's Guide. Model Laser Photo Tachometer User's Guide Model 461920 Laser Photo Tachometer Introduction Congratulations on your purchase of Extech's Mini Laser Photo Tachometer, Model 461920. This Tachometer provides non-contact RPM and Revolution

More information

DPM-3221 Digital DC Power Meter with data logging capability.

DPM-3221 Digital DC Power Meter with data logging capability. Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt),

More information

PowerTrac USB and Link Users Guide Software Installation & Operation Manual

PowerTrac USB and Link Users Guide Software Installation & Operation Manual PowerTrac USB and Link Users Guide Software Installation & Operation Manual MAN-000038-00 REV A TABLE OF CONTENTS POWERTRAC USB USER... 1 POWERTRAC SOFTWARE INSTALLATION AND CONFIGURATION... 2 PREPARATIONS

More information

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control Remote Control for Inverter RC-300 Owner's Manual Please read this manual BEFORE operating your RC-300 Remote Control OWNER'S MANUAL Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

PLD Series +5V Laser Diode Drivers

PLD Series +5V Laser Diode Drivers PLD Series +5V Laser Diode Drivers General Description The PLD series of Laser Diode Drivers combines the high performance you expect from a Wavelength component with two distinct improvements: low voltage

More information

RST INSTRUMENTS LTD.

RST INSTRUMENTS LTD. Carlson/RST MA-7 Readout Instruction Manual 1 RST INSTRUMENTS LTD. Carlson/RST MA-7 Readout Instruction Manual Ltd. 11545 Kingston St Maple Ridge, BC Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005

More information

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD3U Description Tripp Lite Smart Online UPS systems

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD2U Description Tripp Lite Smart Online UPS systems

More information

SERVICE BULLETIN DEPARTMENT OF COMPLIANCE VEHICLE SAFETY AND RECALL MANAGEMENT BUILDING N MAIN ST MIDDLEBURY, INDIANA

SERVICE BULLETIN DEPARTMENT OF COMPLIANCE VEHICLE SAFETY AND RECALL MANAGEMENT BUILDING N MAIN ST MIDDLEBURY, INDIANA SERVICE BULLETIN DEPARTMENT OF COMPLIANCE VEHICLE SAFETY AND RECALL MANAGEMENT BUILDING 11 423 N MAIN ST MIDDLEBURY, INDIANA 46540-9218 Technical Service Bulletin: 225-0754 O Integrity O Safety O Quality

More information

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial MODEL NUMBER: SU3000RTXL3UHV Highlights 3000VA / 3kVA / 2400 watt on-line double-conversion

More information

TS InteliSwitch Digital Time Switch 24VDC/VAC

TS InteliSwitch Digital Time Switch 24VDC/VAC SPECIFICATIONS InteliSwitch Digital Time Switch 24VDC/VAC Voltages... 24VAC, 24VDC, VAC Half Rectified Current Consumption............................ Max. 15mA DC........................................

More information

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual DPM-3321 Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model User Manual Bi-Directional DC Power Meter with built-in USB data logger & adapter. The new DPM-3321

More information

FES LCD Display Version 1.1

FES LCD Display Version 1.1 FES LCD Display Version 1.1 LZ design d.o.o., Brod 3D, 1370 Logatec, Slovenia tel +386 59 948 898 info@lzdesign.si www.front-electric-sustainer.com Table of Content 1. Important notices... 3 1.1 Limited

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

SAT BMS. User Guide. Rev

SAT BMS. User Guide. Rev SAT BMS User Guide Rev001. 2015.11 CONTENTS 1 SAFETY... 3 1.1 General guidance... 3 2 SAT BMS Introduction... 4 2.1 General overview... 4 2.2 BMS General wiring structure... 4 2.3 Hardware... 4 2.4 Program...

More information

SmartOnline 240 & 120V 20kVA 18kW Double- Conversion UPS in 25U enclosure, Pre-installed Network Card, USB, DB9, Bypass, Hardwire

SmartOnline 240 & 120V 20kVA 18kW Double- Conversion UPS in 25U enclosure, Pre-installed Network Card, USB, DB9, Bypass, Hardwire SmartOnline 240 & 120V 20kVA 18kW Double- Conversion UPS in 25U enclosure, Pre-installed Network Card, USB, DB9, Bypass, Hardwire MODEL NUMBER: SU20KRTHWTFASSM Highlights 20kVA / 20,000VA / 18,000W on-line

More information

User Guide. TP3016M Series Switching Mode DC Power Supply

User Guide. TP3016M Series Switching Mode DC Power Supply User Guide TP3016M Series Switching Mode DC Power Supply 1 Introduction I. Quick Start 1.1 Front Panel Description 1.2 Pre-Checking 1.3 Quick Start 1.4 Output Checking II. Specifications 2.1 Major Specification

More information

RGM180 Display Series

RGM180 Display Series Quick Start Guide RGM180 Display Series BG0509 REV.A2 RGM180 QUICKSTART LIMITED WARRANTY The manufacturer offers the customer a 24-month functional warranty on the instrument for faulty workmanship or

More information

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch

SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch MODEL NUMBER: SU20KRT-1TF Highlights 20kVA / 20,000VA / 18,000W on-line double-conversion

More information

RT4F-110V/25A RECTIFIER

RT4F-110V/25A RECTIFIER The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

PRODUCT PRESENTATION PROTECT D.1000 D.3000 APRIL 2012 DATA&IT, SBU C-UPS, PM/SR

PRODUCT PRESENTATION PROTECT D.1000 D.3000 APRIL 2012 DATA&IT, SBU C-UPS, PM/SR PRODUCT PRESENTATION PROTECT D.1000 D.3000 APRIL 2012 DATA&IT, SBU C-UPS, PM/SR CONTENTS A CLASSIFICATION 3 B PRODUCT HIGHLIGHTS 8 C SUMMARY 33 2 A- CLASSIFICATION CLASSIFICATION ACC. TO -AEG S UPS PRODUCT

More information

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

Lux Intelligent Emergency Light Testing System. Lx Features

Lux Intelligent Emergency Light Testing System. Lx Features Lux Intelligent Emergency Light Testing System Lx-9400 The Advanced Lux Intelligent addressable Emergency Lighting Control System is designed provide a simple yet powerful, reliable and cost effective

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

TT /12b INSTALLATION INSTRUCTIONS. Introduction

TT /12b INSTALLATION INSTRUCTIONS. Introduction TT-1545 11/12b INSTALLATION INSTRUCTIONS Original Issue Date: 6/10 Model: 20-300 kw Generator Sets Market: Industrial Subject: Decision-Maker 3000 Controller Service Replacement Kit GM75376 Introduction

More information

TurboCharger T80 Remote Display Installation and Operation Manual

TurboCharger T80 Remote Display Installation and Operation Manual TurboCharger T80 Remote Display Installation and Operation Manual 23 Francis J. Clarke Circle, Bethel, CT 06801 USA (203) 790-6400 www.apollosolar.com TurboCharger T80 Remote Display Installation and Operation

More information

Product Specifications

Product Specifications Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin

More information

AP41 / AP81 SERIES TIME SWITCHES

AP41 / AP81 SERIES TIME SWITCHES FN:AP41_81M1.DOC AP41 / AP81 SERIES TIME SWITCHES AP41 AP81 TABLE OF CONTENTS INTRODUCTION 2 SPECIFICATIONS 2 INSTALLATION 5 FRONT PANEL DESCRIPTION 7 OPERATION 8 Filling out the Program Record Sheet 8

More information

AC/DC TRUE RMS CLAMP METER ACM-2036

AC/DC TRUE RMS CLAMP METER ACM-2036 AC/DC TRUE RMS CLAMP METER ACM-2036 User s Manual Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION Document 476092 User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

SilverLeaf RV-C Control System Training Manual

SilverLeaf RV-C Control System Training Manual 2013 SilverLeaf RV-C Control System Training Manual Newmar Corporation Revised Jan. 2013 Newmar SilverLeaf RV-C Control System Operation/Set-UP Manual SCREEN ACCESS Please be aware that not all of the

More information

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to SM-10 SM-20-A Sound Level Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com SM-10 / SM-20-A Sound Level Meters English Users Manual SM10_Rev002 2009 Amprobe

More information

NX1 Pocket Toner Users Guide

NX1 Pocket Toner Users Guide NX1 Pocket Toner Users Guide The NX1 Pocket Toner lets you quickly do tests for continuity, short circuits, and 50 Ω or 75 Ω termination.the standard adapters let you use the toner on cable with F-type

More information

SA-027WQ. Manual. 7-Day Timer. Lighting Systems Access Controls Security Systems Environmental Controls. Automate the following:

SA-027WQ. Manual. 7-Day Timer. Lighting Systems Access Controls Security Systems Environmental Controls. Automate the following: SA-027WQ 7-Day Timer Manual Automate the following: Lighting Systems Access Controls Security Systems Environmental Controls 12~24 VAC/VDC Program up to 60 flexible events Holiday function (up to 99 days)

More information

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP) Installation and Maintenance Manual IM 852-2 Group: Controls Part Number: IM 852 Date: January 2008 Supercedes: IM 852-1 MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module

More information

Innovative Circuit Technology Ltd.

Innovative Circuit Technology Ltd. Innovative Circuit Technology Ltd. DC UPS Series 2 INSTRUCTION MANUAL 855-146-200 Models: ICT24012-15IBD ICT24012-15IBDM ICT24012-30IBDM WARNING Risk of serious personal injury or damage to equipment and

More information

THOR Battery Backed DC Power Supply Reference Manual

THOR Battery Backed DC Power Supply Reference Manual THOR Battery Backed DC Power Supply Reference Manual Revision A Firmware Compatibility: V1.03 P/N 60098001 Revised: 4/26/2012 INDUSTRIAL CONTROL LINKS, INC. 12840 Earhart Avenue Auburn, CA 95602 Tel: (800)

More information