Operating Manual Touchpad CHALLENGER TPi
|
|
- Darcy Ball
- 6 years ago
- Views:
Transcription
1 Operating Manual Touchpad CHALLENGER TPi GECMA COMPONENTS GMBH TEL FAX. +99 MANUAL TPI REV 1.4 EN.DOC A.J. 1
2 List of Contents List of Contents... 2 Introduction... 2 Available Challenger TPi models... 2 Assembly... 3 Pin Connections... 3 Technical Data... 4 Safety Instructions... 5 General Instructions... 6 Introduction The Challenger Touchpad (TPi) is an intrinsically safe touchpad for the application in zone 0 / zone 22. The touchpad utilizes semi conductive touchpad technology which ensures its operation with fingers, with gloves, with touch pens or similar. It serves to control an ASD (Application Supporting Device) e.g. a PC terminal and it has been designed for the application in an explosion-endangered area. It is equipped with a PS/2 data interface for connection to an intrinsically safe data interface. CHALLENGER TPi is a Microsoft -compatible touchpad and it is also compatible with the standard Microsoft mouse driver. Available Challenger TPi models Various models of Challenger TPi can be supplied: TPi Touchpad TPi-B6 Touchpad with barrier for max. 6.25V TPi-B12 Touchpad with barrier for max. 12.5V GECMA COMPONENTS GMBH TEL FAX. +99 MANUAL TPI REV 1.4 EN.DOC A.J. 2
3 Assembly To ensure the international protection IP66 the touchpad module has to be installed in a housing min. certified according to IP66 (with a cut-out of 153mm x 84mm and/or 6 x 3.3 ). The touchpad module is inserted into the housing cut-out with its front side to the exterior and fastened from the inside via a minimum of four mounting clips which are evenly distributed over the external circumference of the touchpad housing in such a way that the module is tight fitting. The electrical connection can be seen in the wiring diagram # and the license. Pin Connections Connection Significance K42-1 and/or brown and/or 1 Supply circuit +UB K42-2 and/or white and/or 2 Supply / Data circuit GND K42-3 and/or yellow and/or 3 Data K42-4 and/or green and/or 4 Clock Please find the pin numbering in the pin identification plate which is attached near the pin. Details can be found in the wiring diagram # and the license. GECMA COMPONENTS GMBH TEL FAX. +99 MANUAL TPI REV 1.4 EN.DOC A.J. 3
4 Technical Data International ignition protection: Zone 0 Zone 1 Zone 22 II 1 G EEx ia IIC T4 II 2 G EEx ia IIC T4 II 3 D T60 C IP6X Ex ia IIC T4 Ex ia IIC T4 Ex T60 C IP6X Operating temperature: Ta: -20 C C Ta: -40 C C Ta: -25 C C (10 to 90% rel. humidity, n. (-4 F to 140 F) (-40 F to 158 F) (-13 F to 140 F) c.) License: TÜV 04 ATEX 2458 TÜV 04 ATEX 2458 TÜV 04 ATEX 2648X Housing material: Sheet steel / aluminum Housing dimensions: see drawings International Protection Encl.:Front side IP66 (NEMA 4X) with expert installation. Connection supply: Pin K44 2 x ( )mm² rigid / flexible or connecting line Connection interface: Pin K44 2 x ( )mm² rigid / flexible or connecting line Storage temperature: -20 C C (-4 F to 140 F), 10 to 90% rel. humidity, n. cond. Type TPi: Supply voltage: Via intrinsically safe supply unit with the technical data: U max 5.5 V, P max 1000mW, I min > 3 ma C imax 12uF, L i negligible Type TPi-B6: Supply voltage: Via intrinsically safe supply unit with the technical data: U max 6.25 V, I min > 3 ma C i, L i negligible Type TPi-B12: Supply voltage: Via intrinsically safe supply unit with the technical data: U max 12.5 V, I min > 3 ma C i, L i negligible Technical Data Data Via intrinsically safe interface with the technical data: circuit all TPi types: Ui max 5.5 V U o 5.5V, I o 71mA, P o 98mW C i, L i negligible Resistance of the senor area Resistant to most detergents Further details can be found in the license. GECMA COMPONENTS GMBH TEL FAX. +99 MANUAL TPI REV 1.4 EN.DOC A.J. 4
5 Safety Instructions General Safety Instructions The instructions stated in this chapter are to be followed accurately to ensure a safe and reliable operation. The license and the special conditions included in it are to be observed. Follow the national safety regulations and the accident prevention regulations. The installation is only to be performed by specialists. These specialist must be familiar with the characteristics of explosion-endangered facilities. Incorrect or inadmissible application as well as non-observance of the instructions of this operating manual make the guarantee void. Only use this device for the approved purpose. Conversions and modifications to the device are inadmissible. The housing is only to be opened by the company Gecma Components GmbH. Assembly The national assembly and installation regulations are to be observed. The generally accepted rules of engineering are to be observed. The entire equipment is to be connected and operated correctly and properly according to the applicable standards, guidelines and installation instructions. The housing is to be grounded via grounding equipment. Grounding must be effected with a core cross section of at least 4mm². The device is only to be connected in a de-energized condition. The intrinsically safe line system with supply and signal lines has to be effected in such a way that no error must be considered between the individual circuits, see IEC , If a touchpad for use in a dust atmosphere is to be replaced, the device and/or the housing, in which the touchpad is installed, is to be de-energized first and if necessary cooled according to the regulations. Before opening the device and/or housing and during period in which the device and/or the housing is open, the environment of the device and/or housing has to be kept dust-free to such an extent that no dust can enter the interior of the housing. When installing new components observe that all seals are in a flawless condition and function properly. Before putting the device into operation make sure that the device has been installed as prescribed and that the device and its wiring are not damaged. If the power supply of the device is not intrinsically safe, the license will become void and it must not be operated as an intrinsically safe device. If the device was operated intrinsically safely with a low level of international protection (e.g. ib), it must not be operated afterwards in applications for a higher level of international protection (e.g. ia). Operation The device is only to be operated in an undamaged and clean condition. If the device has suffered any damages which might affect the international protection (e.g. cracks, holes or broken components) it must be taken out of service immediately. The device can only be put into operation again after the defect components have been exchanged. When the touchpad is damaged, do not touch it any longer! Risk of injury! If the device is to be used in a dust atmosphere dust layers >5mm have to be removed. In the event of non-observance & non-compliance the stipulated explosion protection cannot be guaranteed and/or the guarantee will become void! Modifications require the written approval by the company GeCma Components GmbH. GECMA COMPONENTS GMBH TEL FAX. +99 MANUAL TPI REV 1.4 EN.DOC A.J. 5
6 General Instructions Before starting the assembly read the entire operating manual! In cases of doubt (in the form of mistranslation) the German operating manual is to be applied. We do not assume liability for misprints and errors in this operating manual. Should you have any questions or suggestions please feel free to contact us any time: GeCma Components GmbH Heisenbergstraße D Kerpen Tel.: +49 (0)22 37 / Fax: +49 (0)22 37 / mailto:info@gecma.com Technical progress The manufacturer reserves the right to adjust all technical data without special announcement according to the technical progress. Repair work, hazardous material The description of the respective fault(s) is in any case to be included with the devices which are sent to GeCma Components GmbH for repair. The following measures are to be taken before sending a device in for repair: Please remove the entire adhering medium residue. Pay special attention to sealing grooves and gaps which might contain medium residue. We have to ask you to refrain from sending the device back if it is impossible for you to definitely guarantee that all health-endangering material has completely been removed. Costs which arise due to inadequate cleaning of the device for a potential disposal or for personal injury (cauterisation, etc.) will be charged to the proprietor of the device. Used trademarks AT, IBM and PS/2 are registered trademarks of the International Business Machines Corporation. Microsoft, Windows and Windows NT are registered trademarks of Microsoft Corporation. All other trademarks mentioned and depicted in the text are trademarks of the respective owners and are recognized as registered. GECMA COMPONENTS GMBH TEL FAX. +99 MANUAL TPI REV 1.4 EN.DOC A.J. 6
7
8
9
10
11
12
13 Translation Translation TÜV CERT (1) EC Design Test Certificate (2) Devices and safety systems for use in accordance with regulations in areas at risk from explosion guideline 94/9/EC (3) EC design test certificate number: TÜV 04 ATEX 2458 (4) Device: Challenger Touchpad Typ TPi (5) Manufacturer: Gecma Components GmbH (6) Address: Heisenbergstr D Kerpen (7) The construction of this device and the different permitted version are specified in the appendix to this design test certificate. (8) The TÜV NORD CERT GmbH & Co.KG, TÜV CERT certification agency, certifies - as appointed office no in accordance with the guideline of the council of the European Community of 23rd March 1994 (94/9/EC) the fulfilment of fundamental safety and health requirements for the design and manufacture of devices and safety systems for correct use in areas at risk from explosion, in accordance with Appendix II of the guideline. The results of the test are set out in the confidential test report no. 04 YEX (9) The basic safety and health requirements are met by conformity with EN 50014: A1 + A1 EN 50020:2002 EN 1127:1997 EN 50284:1999 (10) If there is an X sign behind the certification number, special conditions for the safe use of the device in the appendix to certificate are referred to. (11) This EC design test certificate only relates to the design and testing of the specified device in accordance with guideline 94/9/EC. Further requirements of these guidelines apply for the manufacturing and the bringing into circulation of this device. These requirements are not covered by this certificate. (13) Annex (14) EC Type Test Certificate No. TÜV 04 ATEX 2458 (15) Description of the equipment: The Challenger Touchpad (TPi) is an intriniscally safe operating device, e.g. for controlling a pointer on a display. It features a PS2 data interface for connection to an intrinsically safe data transmission unit. Behind the front plate the electronic components are protected with a housing of at least IP 20. The protection from front is IP65. Is a higher enclosureprotection necessary the unit have to be mountet in a suitable hausing. The connection can be made via a premanufactured terminal strip or K44 connection. The maximum cablelength is 50m. Refer following text. In the frontplate can be mountet, beside the sensorsurface, up to two buttons. The permitted ambient temperature range for each type can be found in the following table: Electrical Data Type TPi Category Ambient Temperature Range 1-20 C to 60 C 2-40 C to 70 C Supply Current and Interface Circuit (Terminals K44-1 or cable brown or 1; K44-2 or cable white or 2 Data: Terminals K44-3 or cable yellow or 3 Clock: Terminal K44-4 or cable green or 4) In explosion protection type intrinsically safety EEx ia IIC/IIB Only for connection to certified intrinsically safe circuits Ui = 5.5 V P i = 950mW C i = 12uF The effective internal inductance are negligibly small. (12) The marking of the device must contain the following information: II 1 G EEx ia IIB T4 and II 2 G EEx ib IIC T4, resp. TÜV NORD CERT GmbH & Co. KG Hannover, TÜV CERT certification body Am TÜV 1 D Hannover Phone: Fax: The Challenger Touchpad Typ TPi are suitable for mount and connecting to the under DMT 00 ATEX E 089 X with 1. supplement, certificatet devices Challenger KB, KB-2*, KMU, KMU-2*, MTD, MTD-2* and under TÜV 03 ATEX 2251 certificatet devices KB-FPi and KB-2D-FPi instead of Challenger TB and Challenger M. Becouse of the protectionlevel and category of the in the top listed devices the protectionlevel of the intrinsically safe circuits are ib and category 2 of the complete equipment. The maximum permitted cablelength are 5m sd./- illegible The Head This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 1 of 3 This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 2 of 3
14 Translation Translation Annex to EC Type Test Certificate No. TÜV 03 ATEX 2458 (16) The test documents are listed in test report no. 04 YEX First Supplement for TÜV CERT EC Design Test Certificate TÜV 04 ATEX 2458 (17) Particular requirement: None (18) Fundamental safety and health requirements: None in addition Device: Challenger Touchpad Typ TPi, TPi-B6 and TPi-B12 Manufacturer: Gecma Components GmbH Address: Heisenbergstr D Kerpen The Challenger Touchpad type TPi will be expanded with the types TPi-B6 and TPi-B12 Additional the mechanical construction modified. Optional a button can be located to the Electrical Data When use in category 1 G the circuits must be protected by protectionlevel ia. Type TPi Supply Current and Interface Circuit (Terminals K44-1 or cable brown or 1; K44-2 or cable white or 2, Data: Terminals K44-3 or cable yellow or 3 Clock: Terminal K44-4 or cable green or 4) In explosion protection type intrinsically safety EEx ia IIC/IIB Only for connection to certified intrinsically safe circuits Ui = 5.5 V Pi = 950 mw C i = 12uF The effective internal inductance are negligibly small. Type TPi-B6 Supply Current Circuit (Terminals K44-1 or cable brown or 1; K44-2 or cable white or 2) In explosion protection type intrinsically safety EEx ia IIC/IIB Only for connection to certified intrinsically safe circuits Ui = 6,25 V U o = Ui of datacircuit I o = 84 ma (short term) I o = Ui of datacircuits but 47 ma (static) P o = P i of datacircuit but 64mW Characteristic curve: linear The effective internal capacitances and inductance are negligibly small. This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 3 of 3 This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 1 of 3
15 Translation Translation Annex to 1. supplement of EC Type Test Certificate No. TÜV 03 ATEX 2458 Annex to 1. supplement of EC Type Test Certificate No. TÜV 03 ATEX 2458 Interface circuit (Data: Terminals K44-3 or cable yellow or 3 Clock: Terminal K44-4 or cable green or 4) In explosion protection type intrinsically safety EEx ia IIC/IIB Ui = 5.5 V U o = Ui of datacircuit I o = 169 ma (short term) I o = I i of datacircuit but 47mA (static) P o = P i of datacircuit but 64mW Characteristic curve: linear The effective internal capacitances and inductance are negligibly small. TÜV NORD CERT GmbH & Co. KG Hannover, TÜV CERT certification body Am TÜV 1 D Hannover Phone: Fax: sd./- illegible The Head Type TPi-B12 Supply Current Circuit (Terminals K44-1 or cable brown or 1; K44-2 or cable white or 2) In explosion protection type intrinsically safety EEx ia IIC/IIB Only for connection to certified intrinsically safe circuits Ui = 12,5 V U o = Ui of datacircuits I o = 169 ma (short term) I o = Ii of datacircuits but 47 ma (static) P o = P i of datacircuit but 64mW Characteristic curve: linear The effective internal capacitances and inductance are negligibly small. Interface circuit (Data: Terminals K44-3 or cable yellow or 3 Clock: Terminal K44-4 or cable green or 4) In explosion protection type intrinsically safety EEx ia IIC/IIB Only for connection to certified intrinsically safe circuits Ui = 5.5 V U o = Ui of supplycircuit I o = 321 ma (short term) I o = I i of datacircuit but 107mA (static) P o = P i of datacircuit but 334mW Characteristic curve: linear The effective internal capacitances and inductance are negligibly small. Note the rules for connecting intrinsically safe circuits. The intrinsically safe circuits are galvanic together connected. All other specifications valid without changes. The test documents are listed in test report no. 04 YEX f. This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 2 of 3 This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 3 of 3
16
17 Translation Translation TÜV CERT (1) Declaration of conformity (2) Devices and safety systems for use in accordance with regulations in areas at risk from explosion guideline 94/9/EC (3) EC design test certificate number: TÜV 04 ATEX 2648 X (4) Device: Challenger Touchpad Typ TPi, TPi-B6 and TPi-B12 (5) Manufacturer: Gecma Components GmbH (6) Address: Heisenbergstr D Kerpen (7) The construction of this device and the different permitted version are specified in the appendix to this design test certificate. (8) The TÜV NORD CERT GmbH & Co.KG, TÜV CERT certification agency, certifies - as appointed office no in accordance with the guideline of the council of the European Community of 23rd March 1994 (94/9/EC) the fulfilment of fundamental safety and health requirements for the design and manufacture of devices and safety systems for correct use in areas at risk from explosion, in accordance with Appendix II of the guideline. The results of the test are set out in the confidential test report no. 04 YEX b. (9) The basic safety and health requirements are met by conformity with EN : A1 :2002 (10) If there is an X sign behind the certification number, special conditions for the safe use of the device in the appendix to certificate are referred to. (11) This EC design test certificate only relates to the design and testing of the specified device in accordance with guideline 94/9/EC. Further requirements of these guidelines apply for the manufacturing and the bringing into circulation of this device. These requirements are not covered by this certificate. (12) The marking of the device must contain the following information: II 3 D T60 C IP 6X (13) Annex (14) EC Type Test Certificate No. TÜV 04 ATEX 2648 X (15) Description of the equipment: The Challenger Touchpad type TPi, TPi-B6 and TPi-B12 is an dustproofed operating device, e.g. for controlling a pointer on a display. It features a PS2 data interface for connection to an intrinsically safe data transmission unit. The electrical connection realized with terminals or with a premounted cable, whereby the electrical connection normally realized inside the additional enclosure. In the frontplate can be mountet up to two buttons. The operationtemperature specified to -25 C up to 6 0 C. Electrical Data Supply Current Circuit (Terminals K44-1 or cable brown or 1; K44-2 or cable white or 2) Interface circuit (Data: Terminals K44-3 or cable yellow or 3 Clock: Terminal K44-4 or cable green or 4) To connect to circuits with follow max. values under normal conditions: U = 5,5V for type TPi U = 6,25V for type TPi-B6 U= 12,5V for type TPi-B12 To connect to circuits with follow max. values under normal conditions: U = 5,5V (16) The test documents are listed in test report no. 04 YEX b. (17) Particular requirement: The Touchpad must be installed in this way that it is protected against high mechanic danger. The Challenger Touchpad must be mounted into a enclosure which fulfill the requirements of category 3D EN as minimum. (18) Fundamental safety and health requirements: None in addition TÜV NORD CERT GmbH & Co. KG Hannover, TÜV CERT certification body Am TÜV 1 D Hannover Phone: Fax: sd./- illegible The Head This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 1 of 2 This certificate must only be circulated without any modification. Excerpts or changed require the approval of TÜV NORD CERT GmbH & Co. KG Page 2 of 2
18
19
20
21
22
23
24
25
26
27
Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B
Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B GECMA.COMPONENTS GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX -99 MANUAL MI_PS2_B REV 1.3 EN.DOC 31.01.07 A. J. 1 List of contents List of contents... 2
More informationOperating Manual Panel PC EXPLORER 15i EXPLORER 18i
Operating Manual Panel PC EXPLORER 15i EXPLORER 18i Doc: 60000206 GECMA COMPONENTES GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX. -99 MANUAL EXPLORER REV 1.10 EN.DOC 13.05.08 A.J. 1 Contents Contents.........
More informationOperating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015
Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationOperating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern
Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents
More informationSignal processor MS96 for flow sensors MS96-11EX0-R/230VAC
MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationOperating Manual ExMod Ex-Module Base station e.g. for BCSi / Data transmission module
GECMA Components GmbH Operating Manual ExMod -1-2-3 Ex-Module Base station e.g. for BCSi / Data transmission module Doc.Nr.:60000321 MANUAL EXMOD-1-2-3 EX-MODULE BASE STATION REV 1.6 EN.DOC 19.12.08 N.B
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationPROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32
PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 With regard to the supply of products, the current issue of the following document is applicable: The General Terms
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationIntrinsically safe batch controller Batching Master 110i
Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199
More informationEmergency power supply NV2.1-12iaE
Ordering Data Designation Type Item no. 372 100 04 AX Supply of consumers even in case of failure or shutdown of the input / charging current circuit NiCd as energy store Intrinsically safe input voltage
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More information(1) EC-TYPE-EXAMINATION CERTIFICATE (Translation) (2) Equipment and protective systems intended for use in potentially explosive atmospheres Directive 94/9/EC (3) EC-type-examination Certificate number
More informationPHOENIX CONTACT - 02/2008
Ex-i solenoid driver for Group IIC gases, loop-powered, pluggable INTERFACE Data Sheet 103211_00_en PHOENIX CONTACT - 02/2008 1 Description The solenoid driver PI-EX-SD-21-25 links a signaling device installed
More informationInterface and Supply module. IPC 3x0i / PSC 3x0i
Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com
More informationOperating Instructions
Operating Instructions KBDi-DS102W-xxx R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.05 Issue date: 19.09.2018 Disclaimer Disclaimer Publisher and copyright
More informationInstallation Instruction. HART Add-On Module
- Translation Typs 17-A1Z0-0005, B7-A2Z0-0033 and G7-A0Z0-0007 Version for: Non hazardous areas ATEX/IECEx Zone 1 and Zone 2 UL Class I Division 1 and Division 2 Document No.: B1-A2Z0-7N0001 / 400570 Revision
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99
More informationPTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions
, Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:
More informationEXPLORER. Industrial Panel PC - Flexible Modular Design
Gecma Explorer series HAZARDOUS AREA PC s Ex Zone 1 / 2 (Gas) Ex Zone 21 / 22 (Dust) Hazardous areas Industrial Panel PC - Flexible Modular Design For Ex Zone 1 / 2 (Gas) Class I, Zone 1 / Class I, Div.
More informationPTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions
Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation
More informationADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.
EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier
More informationSafety instructions. IECEx TUN Ex ia IIC T6 Gb
Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions
More informationRefer to attachment for more details. Andreas Meyer
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationLoop-powered Transmitter for Thermocouple Type K (NiCr-Ni)
Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation
More information4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12
0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring
More informationSmart Wireless THUM Adapter
Quick Installation Guide Smart Wireless THUM Adapter Smart Wireless THUM Adapter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications
More informationZener Barriers Bulletin 937Z
Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution
More informationSpeaking Station LV30
Speaking Station LV30 Ordering data Designation Type Item no. Speaking station with cable entries LV 30 300 0 AX Speaking station with plug connectors (socket / socket) Speaking station with plug connectors
More informationMACX MCR-EX-SD LP(-SP)
Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)
More informationSafety instructions VEGATOR 121, 122
Safety instructions Intrinsic safety IECEx TUN 14.0005X Document ID: 47471 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Installation... 4 Supplementary documentation:
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationTechnical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm
Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function
More informationTechnical Data. General specifications. Output type Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone 2 and zone 22 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationSMARTLINE RM76 Supplementary instructions
SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the
More informationM E M O R A N D U M I.S.
Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M
More informationExplosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter
Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationMANUAL Surge Protectors
PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationPower supply unit NG3-16ib
Ordering Data Designation Type Item no. Power supply unit NG3-16ib (42 V AC / ) 371 008 31 AX Power supply unit NG3-16ib (230 V AC / ) 371 008 32 AX Power supply unit NG3-16ib (100 V AC / ) 371 008 34
More informationSeparating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information
Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................
More informationTFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5
EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More information4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available
More informationEX- Documentation VA 450 / VA 452. thermal mass flow sensor
EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the
More informationOperating Manual. icam100
icam100 This page is intentionally left blank. Document Number 302803 (See Last Page for Revision Details) 2006 Extronics Limited. This document is Copyright Extronics limited. Extronics reserve the right
More informationMINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description
Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from
More informationDR7100 SERIES Supplementary instructions
DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationVibration Sensor Type 640
Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Instruction Manual English Instruction Manual Vibration Sensor Type 640 Standard Zone-1-21 Zone-2-22 Edition: 12.04.10 Attention! Before Start-Up
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationSafety instructions Overvoltage protection B81-35
Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationFieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)
Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field
More informationPTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21
Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21 Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Operating Instructions Bedienungsanleitung
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationINSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069
D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according
More informationRosemount 248 Wireless Temperature Transmitter
Quick Installation Guide Rosemount 248 Wireless Rosemount 248 Wireless Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationMDM 011-Z1 Regen Resistor
MDM 011-Z1 Regen Resistor Date of creation: 10.04.2017 Version date: 10.04.2017 Article number: 09-402-011-Z1-E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax: 06274/4321-18
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationSafety Instructions Omnigrad TRxx, TCxx, TxCxxx
XA01459T/09/EN/01.16 71340269 Products Solutions Services Safety Instructions Omnigrad TRxx, TCxx, TxCxxx RTD/TC modular thermometers 0ExiaIICT6...T1 X Document: XA01459T Safety instructions for electrical
More informationTechnical Data. Dimensions
Model Number Features 50 mm flush -wire DC S Technical Data specifications Switching function Normally open (NO) Output type PNP Rated operating distance s n 50 mm Installation flush Output polarity DC
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationThe Solid-State Decoupler (SSD)
The Solid-State Decoupler (SSD) Installation Instructions Introduction The Solid-State Decoupler (SSD) is a solid-state DC isolation/ac grounding (i.e., coupling) device design ed for use in conjunction
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationElectronic Temperature Controller. Instruction Manual Version
Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationInductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi
ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring
More informationInductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More informationDocumentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:
Documentation Fan cartridge for EtherCAT and Bus Terminals Version: Date: 1.5 2017-08-07 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationishrt USB ishrt USBeX the Bluepack User Manual
ishrt USB ishrt USBeX the H@rt Bluepack User Manual Content 1. Certificate of conformity...1 2. ishrt USB and ishrt USBeX...4 2.1. Technical details...5 2.2. Delivery content...5 3. the H@rt Bluepack...6
More informationMagnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.
More informationMINI MCR-SL-MUX-V8-FLK 16
Multiplexer Data sheet 445_en_4 PHOENIX CONTACT 22-5-2 Description The MINI Analog multiplexer can be used to generate one analog output from up to eight input signals. During cyclical execution, 8, 6,
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationLevel switch for tank installation. NT 61-Z0-Atex. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2017
Fluidcontrol Level switch for tank installation NT 61-Z0-Atex Installation and Operation Instructions Original instructions BE100028 10/2017 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel.
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More informationThe 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.
February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationEnglish. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM
English Operating Manual Conductive point level switch MLR120 Companies / brands of GHM www.ghm-group.de Retain for later reference Table of contents Page 1. Proper use (application areas)... 3 Safety
More information