3
4
5
6
7 (1) EC-TYPE-EXAMINATION CERTIFICATE (Translation) (2) Equipment and protective systems intended for use in potentially explosive atmospheres Directive 94/9/EC (3) EC-type-examination Certificate number PTB 00 ATEX 1112 U (4) Components: Contact block type 8080/1-. (5) Manufacturer: R. Stahl Schaltgeräte GmbH (6) Address: Waldenburg (Württ.), GERMANY (7) This component and any acceptable variation thereto are specified in the schedule to this certificate. (8) The Physikalisch-Technische Bundesanstalt notified body No.0102 in accordance with Article 9 of the European Council Directive 94/9/EC of 23rd March 1994 certifies that this component has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment and protective systems intended for use in potentially explosive atmospheres, given in Annex II to the Directive. The examination and test results are recorded in the confidential report PTB Ex (9) Compliance with the Essential Health and Safety Requirements has been assured by compliance with: EN 50014: A1 + A2 EN 50018: 1994 EN 50019: 1994 (10) The sign U after the certificate number indicates that this certificate must not be confused with certificates issued for equipment or protective systems. This Component Certificate only serves as a basis for the issuing of certificates for equipment or protective systems. (11) This EC-type-examination Certificate relates only to the design and construction of the specified component in accordance with Directive 94/9/EC. Further requirements of this Directive apply to the manufacture and supply of this component. (12) The marking of the component shall include the following: II 2 G EEx de IIC I M 2 EEx de I Certification office Explosion protection Braunschweig, 3. May 2001 By order: gez. Klausmeyer Dr.-Ing. U. Klausmeyer Regierungsdirektor
8 Physikalisch-Technische Bundesanstalt Braunschweig and Berlin Appendix to EC-Type-Examination Certificate PTB 00 ATEX 1112 U (13) Schedule (14) EC-Type-Examination Certificate PTB 00 ATEX 1112 U (15) Description of component Contact block 8080/1-. is a flameproof switching element and is used to switch main, control and signal circuits. Connections are made by means of integral terminals. Technical data Rated insulation voltage... up to 550 V Rated operating voltage... up to 125 V 250 V 500 V Rated current I e... max. 10 A 0,2 A 10 A Switching capacity DC-12 DC-12 AC-15 Rated values other than those listed above are permitted provided the making and breaking capacities in the relevant regulations are complied with and are stipulated by the manufacturer depending on mode of operation, switching capacity, etc. Contacts...NO and/or NC (positive opening) Rated connection capacity 2.5 mm² Can be used for temperature class T6 Ambient temperature -55 C to 50 C Ambient temperature -55 C to 70 C at rated thermal current, max.. 10 A 6 A The contact block is designed for thermal stability from -55 C to 100 C. (16) Test report PTB Ex (17) Special conditions for safe use none Notes on manufacture and operation The contact block must be fitted into an enclosure which complies with the requirements of a specific type of protection as detailed in EN 50014, Part 1.2. Seite 2/3 EC-type-examination Certificates without signature and official stamp shall not be valid. The certificates may be circulated only without alteration. Extracts or alterations are subject to approval by the Physikalisch-Technischen Bundesanstalt. In case of dispute, the German text shall prevail. Physikalisch-Technische Bundesanstalt Bundesallee 100 D Braunschweig
9 Physikalisch-Technische Bundesanstalt Braunschweig and Berlin Appendix to EC-Type-Examination Certificate PTB 00 ATEX 1112 U When fitting the contact block into an enclosure with type of protection Increased Safety e to EN 50019, the clearances and creepage distances given in Parts 4.3, 4.4 and Table 1 must be maintained. The component is suitable for use in both Group I and II, because the standard requirements are identical in this case. This EC Type-Examination Certificate and any future amendments to it are simultaneously valid as amendments to Component Certificate PTB No. Ex-96.D.1019 U. (18) Essential health and safety requirements The tests carried out and their positive results demonstrate that the contact block complies with the requirements of Directive 94/9/EC and the standards specified on the cover sheet. Certification office Explosion protection Braunschweig, 3. May 2001 By order gez. Klausmeyer Dr.-Ing. U. Klausmeyer Regierungsdirektor Seite 3/3 EC-type-examination Certificates without signature and official stamp shall not be valid. The certificates may be circulated only without alteration. Extracts or alterations are subject to approval by the Physikalisch-Technischen Bundesanstalt. In case of dispute, the German text shall prevail. Physikalisch-Technische Bundesanstalt Bundesallee 100 D Braunschweig
10
11
Uncertified Translation Physikalisch-Technische Bundesanstalt Braunschweig und Berlin (1) EC Type Examination Certificate (2) Equipment and Protective Systems Intended for Use in Potentially Explosive
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx PTB 05.0013 issue No.:2
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:3 Status: Current Date of Issue: 2012-10-12
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity Certificate No.: IECEx PTB 10.0014U Date of Issue: 2010-03-02 Issue No.: 0 Page 2 of 3 Manufacturer: BARTEC GmbH Max-Eyth-Straße 16 97980 Bad Mergentheim Germany Manufacturing
More informationIECEx Certificate of Conformity
Certificate : IECEx PTB 04.0005 http://iecex.iec.ch/iecex/iecexweb.nsf/certificatesajax/iecex%20ptb%2004.0005%... Seite 1 von 4 10.01.2013 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme
More informationPhysikalisch-Technische Bundesanstalt P1B
Physikalisch-Technische Bundesanstalt P1B Braunschweig und Berlin 1. SUPPLEMENT according to Directive 94191EC Annex 111.6 to EC-TYPE-EXAMINATION CERTIFICATE PTB 12 ATEX 2030 (Translation) Equipment: Marking:
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationIECEx Certificate of Conformity
--- Certificate : ECEx PTB 13.0036X Seite 1 von 5 ECEx Certificate ------ -- l "-- - --- --- NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx BKI 07.0001X issue No.:1
More informationM E M O R A N D U M I.S.
Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M
More informationPTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions
, Equipment protection fuse with Ex mb II C Gb approval Geräteschutzsicherung mit Zulassung Ex mb II C Gb Fusible de protection d appareil avec homologation Ex mb II C Gb Example / Beispiel / Exemple:
More informationExplosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter
Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2
More informationSignal processor MS96 for flow sensors MS96-11EX0-R/230VAC
MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment
More informationEC-Type Examination Certificate
( 1) (2) Translation 1st Supplement to the EC-Type Examination Certificate Equipment and protective systems intended for use in potentially explosive atmospheres - Directive 94/9/EC Supplement accordant
More informationMicro Limit Switch Series 8064
> For universal application > Versions with snap-action contact positive opening contact > With connecting cable or with single cores when it is used as a built-in device > Width Single limit switch 11
More informationADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.
EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier
More informationMicro Motion, Inc. Page 1 of 6
EB-20025742 Revision: AA Number of Pages: 6 Comments: Originator: HVH 10/01/13 Approved: RCS 11/26/13 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 11/26/13 Micro Motion, Inc. Page
More informationI Ex-Installation switch I
I Ex-Installation switch I Switch/Pushbutton Technical data 4 Ex-installation switch and Ex-pushbuttons Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate
More informationPTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions
Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Example / Beispiel / Exemple Type 6106 Operating Instructions Bedienungsanleitung Manuel d utilisation
More informationOperating Manual Touchpad CHALLENGER TPi
Operating Manual Touchpad CHALLENGER TPi GECMA COMPONENTS GMBH WWW.GECMA.COM TEL. +49 2237 6996-0 FAX. +99 MANUAL TPI REV 1.4 EN.DOC 31.01.07 A.J. 1 List of Contents List of Contents... 2 Introduction...
More informationSolConeX extra-low voltage flange socket
SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3
More informationRefer to attachment for more details. Andreas Meyer
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationCradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N
Cradle relay AC Cradle relay for alternating voltage, neutral, monostable. High-quality cradle relays for AC are installed as encapsulated flameproof elements in the MODEX enclosure. The IP 66 protection
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - P O W E R C I R C U I T B R E A K E R S Up to 630 A CEAG power circuit breakers enable making or breaking of circuits under normal operating conditions as well as cutting in, briefly conducting and
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationSUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
1. SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE 2. Equipment or Protective System Intended for use in Potentially Explosive Atmospheres Directive 94/9/EC 3. Type Examination Certificate Number: ITS13ATEX47876X/1
More informationSolConeX Wall-Mounted Socket, 16 A
SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx FTZU 14.0004X Current
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationPTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21
Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21 Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Operating Instructions Bedienungsanleitung
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx TRC 12.0010X Current
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Date of lssue: Applicant:
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationOperating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern
Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationINTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Issue No.
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationOverload Relays. 3RB2 Solid-State Overload Relays. 3RB20, 3RB21 for standard applications. 5/48 Siemens LV Overview
Overload Relays Siemens AG 2009 Overview 1 2 2 (1)Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors and soft starters, these connecting
More informationOperating Instructions
Operating Instructions KBDi-DS102W-xxx R. STAHL HMI Systems GmbH Adolf-Grimme-Allee 8 D 50829 Köln Operating Instructions Version: 01.00.05 Issue date: 19.09.2018 Disclaimer Disclaimer Publisher and copyright
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationEX- Documentation VA 450 / VA 452. thermal mass flow sensor
EX- Documentation VA 450 / VA 452 thermal mass flow sensor This document contains important information for the installation and operation of the flow sensor in explosive environments. Please read the
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationMINI MCR-SL-CVS NC
Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ITA 14.0009X Issue No:
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx LCI 10.0010X issue No.:1
More informationMetal Position Switch
Metal osition Switch Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...2
More informationINSTALLATION TECHNOLOGY MADE EASY
INSTALLATION TECHNOLOGY MADE EASY Pre-assembled branching/terminal boxes for Zone 1 and Zone 21 Each user can enjoy the benefits of the exlink with the pre-assembled branching boxes without having to first
More informationThis explosion proof Pulse Generator is equipped with an inductive sensor for use in
Quick reference 50 pulses per revolution of measuring drum For use with TG05 to TG50 and BG4 to BG100 Uni-directional Applicable for ex-proof areas (1) Application The Pulse Generator for RITTER Drum-type
More informationPower supply unit NG3-16ib
Ordering Data Designation Type Item no. Power supply unit NG3-16ib (42 V AC / ) 371 008 31 AX Power supply unit NG3-16ib (230 V AC / ) 371 008 32 AX Power supply unit NG3-16ib (100 V AC / ) 371 008 34
More informationThe Solid-State Decoupler (SSD)
The Solid-State Decoupler (SSD) Installation Instructions Introduction The Solid-State Decoupler (SSD) is a solid-state DC isolation/ac grounding (i.e., coupling) device design ed for use in conjunction
More informationProviding flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.
e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the ECEx Scheme visit www.iecex.com Certificate No.: Status: Current Issue No: 1 Certificate
More informationInterface and Supply module. IPC 3x0i / PSC 3x0i
Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com
More informationData sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.
Data sheet Constant current DALI LED control gear 8 W Output power 5 7 ma Output current Intelligent temperature protection Linear VI LED Linear VI LED control gear More than 25 years of experience in
More informationControl Buttons / Switches for Panel Mounting Series 8003
www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch selector switch > 2 contact elements
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ITA 10.0006X Issue No:
More informationBVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363
BVS 17 ATEX E 117 X / IECEx BVS 17.0100X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363 Electromotive control valve with ATEX approval and IECEx approval Elektromotorisches
More informationOperating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505
Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More informationPosition Switches Series 8070
www.stahl.de > Enclosures of type of protection "Increased safety > Dimensions and characteristic values according to EN 50041 > Replaceable contact in flameproof enclosure > Positive opening contacts
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More informationBVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire
/ IECEx BVS 16.0091 X Types 8791, 8792, 8793 Position controller and process controller with II 3G Ex ec ic IIC T4 Gc / II 3D Ex tc IIIC T135 C Dc approval Stellungsregler und Prozessregler mit Zulassung
More informationCoil Type 3009M. This document cannot be modified without the approval of the Certification Institute 1/4
Coil Type 3009M Coil Type 3009M UE DECLARATION OF CONFORMITY 1/4 Coil Type 3009M COIL 3009M II 2G Ex mb IIC Tx Gb II 2D Ex tb IIIC Tx C Db to be used in potentially explosive atmosphere We, AMISCO S.p.A.,
More informationIECEx Certificate of Conform ity
-------- -- - IECEx Certificate INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certitication Scheme tor Explosive Atmospheres tor rules and details of the IECEx Scheme visit v..ww.iecex.com Certificate
More informationBVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363
BVS 17 ATEX E 117 X / IECEx BVS 17.0100X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363 Electromotive control valve with ATEX approval and IECEx approval Elektromotorisches
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationPHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),
Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationWG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.
Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationETD-BL-1T-OFF-CC- 10S
Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time
More informationDAkkS Who we are. Attesting competence, Assuring quality, Creating confidence.
DAkkS Who we are Attesting competence, Assuring quality, Creating confidence. What is accreditation? Reliability through conformity assessment The demands on the quality of goods and services are growing
More informationTEPI11 P/I signal converter
Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationPage 1 of 5. Increased Safety, Encapsulation and Dust
IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex com Certificate No.: Status: Date of Issue: IECEx
More informationRAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description
I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx UL 15.0032X Current
More informationMINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description
Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from
More informationECE Cert.fic te of Con ormity
ECE Cert.fic te of Con ormity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex.com Certificate No.:
More informationDatasheet - AZ 15 ZVRK
24.12.2015-09:51:40h Datasheet - AZ 15 ZVRK Safety switch with separate actuator / AZ 15 Preferred typ Thermoplastic enclosure Double-insulated Long life 52 mm x 75 mm x 30 mm Multiple coding Large wiring
More informationIsolating repeater IRU 420
Isolating repeater IRU 420 Universal intrinsically safe isolating repeater of current signals 0/4 20 ma with option voltage output 0 10 V For supply sensors with output 0/4 20 ma in Galvanic separation
More informationType Switching repeater. Safety manual
Type 9170 Switching repeater Safety manual Safety manual English Content 1 General information... 3 1.1 Manufacturer... 3 1.2 Information regarding the Safety Manual... 3 1.3 Area of application... 3 1.4
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail
Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:5 Status: Current Date of Issue: 2016-04-06
More informationDeltaV Bulk Power Supplies
DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to
More informationType 9160 / Transmitter supply unit / Isolating repeater. Safety manual
Type 9160 / 9163 Transmitter supply unit / Isolating repeater Safety manual Safety manual English Content 1 General information... 3 1.1 Manufacturer... 3 1.2 Information regarding the Safety Manual...
More informationOperating instructions
Operating instructions Digital Input Output Module > Contents 1 Contents 1 Contents...2 2 General information...3 2.1 Manufacturer...3 2.2 Information regarding the operating instructions...3 2.3 Conformity
More informationElectronic Temperature Controller. Instruction Manual Version
Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found
More informationNemko 98ATEX201 SUPPLEMENT 4 TO EC-TYPE EXAMINATION CERTIFICATE. [13] Schedule. [14] EC-TYPE EXAMINATION CERTIFICATE No Nemko 98ATEX201
Nemko 98ATEX201 Page I of I SUPPLEMENT 4 TO EC-TYPE EXAMINATION CERTIFICATE [13] Schedule [14] EC-TYPE EXAMINATION CERTIFICATE No Nemko 98ATEX201 [15] Description of Equipment or Proteetive System This
More informationGRP Flameproof Visual Signal Xenon or Steady LED
GRP Flameproof Visual Signal Xenon Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the
More informationBA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3
TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting
More information