LPC Rev D 11/15/07 HERYTAGE. H16kVA and H20kVA Configuration Guide
|
|
- Darrell Morrison
- 6 years ago
- Views:
Transcription
1 LPC Rev D 11/15/07 HERYTAGE H16kVA and H20kVA Configuration Guide
2 The HERYTAGE order number is determined by the configuration or options selected. This guide will assist in configuring the product and determining the list price. The resulting order number should be 15 digits in length. Example Order Number: H16BB00AA0A0A0A The digits in the order number designate the following: Digits 1-5 Digit 6 Digit 7 Digit 8 Digit 9-14 Digit 15 - The kva rating, input voltage and output voltage of the UPS. - Battery configuration (internal, external, or less battery). - Bypass option. Currently only external bypass is allowed. - Input Connection - Output connect, receptacle type and quantity - Other options Items that are not directly attached to the UPS from the factory, such as external maintenance bypass switches and battery packs, will need to be ordered as a separate line item and are shown under the External Accessories section. Base Model (Digits 1-5) KVA Rating Input Voltage Output Voltage Order Code List Price 16KVA 20KVA 208 In 240 In 208 In 240 In 120 / 208 Out H16BB $13, / 240 Out H16BC $13, / 208 Out H16CB $13, / 240Out H16CC $13, / 208 Out H20BB $14, / 240 Out H20BC $14, / 208 Out H20CB $14, / 240Out H20CC $14,900 Battery Options (Digit 6) Battery Option Charger Order Code Price Set up for External Battery Standard 2 $0 Bypass Options (Digit 7) Bypass Option Order Code Price No Internal Bypass 0 $0
3 Input Connection Options (Digit 8) Input Connection Option Input Voltage Required Order Code Price Hardwired Any A $0 Output Connection Options (Digit 9-14) Output Connections are specified by three sets of 2 digits (9-10, 11-12, 13-14). Each set is used to specify a type of receptacle and the quantity of that type. If hardwired output is desired, all sets should be A0 (A0A0A0). The receptacles should be specified alphabetically by the order code. Unneeded sets should remain A0. If a quantity of two (2) NEMA 5-20 and one (1) NEMA L6-30 receptacles are desired the digits should be C2K1A0. A total quantity of three (3) receptacles can be specified. Output Connection Option Output Voltage Required Order Code Price Ea. Hardwired Any A $0 NEMA B $70 NEMA C $70 NEMA L D $100 NEMA L E $100 NEMA L F $100 NEMA or 240 G $100 NEMA or 240 H $100 NEMA L or 240 I $100 NEMA L or 240 J $100 NEMA L or 240 K $100 Other Internal Options (Digit 15) Other Options Order Code Price No Other Options A $0 Neutral to Ground Bond Removal (For Shipboard Applications) B $50 Anchor Kit C $450 Anchor Kit and Neutral to Ground Bond Removal for Shipboard Applications D $500 Internal Modem Option M $300
4 External Accessories External options, such as maintenance bypass switches and battery packs must be ordered as a separate line item. External Maintenance Bypass Switches Part Number Description UPS Output Voltage Price SW125BBMA SW125BBMC SW125BBML SW125MBBA SW125MBBC SW125MBBL 125 Amp Break-Before-Make with AC Disconnect, Wall Mounted 125 Amp Break-Before-Make with AC Disconnect and Aux. contacts, Wall Mounted 125 Amp Break-Before-Make with AC Disconnect and Lock Option, Wall Mounted 125 Amp Make-Before-Break with AC Disconnect, Wall Mounted 125 Amp Make-Before-Break with AC Disconnect and Aux. contacts, Wall Mounted 125 Amp Make-Before-Break with AC Disconnect and Lock Option, Wall Mounted Any $990 Any $1,010 Any $1, or 120/240 $1, or 120/240 $1, or 120/240 $1,390 External Battery Packs and Accessories Part Number Description Price BP096B1250 Battery Pack for 16kVA system. Includes battery cabinet, (8) BBAT batteries, and cables. Can be daisy chained for additional runtime. $4,250 BP120B1250 BP Battery Pack for 20kVA system.includes battery cabinet, (10) BBAT batteries, and cables. Can be daisy chained for additional runtime. 250A Battery Cabinet with DC disconnect, precharge, and cabinet to cabinet cables. Does not include batteries or battery interconnect cables. $4,775 $1750 MCAK Battery interconnect cable kit for (8) BBAT batteries. $185 MCAK Battery interconnect cable kit for (10) BBAT batteries. $210 MANC Anchor Kit for Battery Cabinet $450 BBAT UPS12-300MR, 12 volt, 300 WPC. Replaces BBAT-0103 Call BBAT UPS12-350MR, 12 volt, 350 WPC. Replaces BBAT-0122 Call External Communication Options Part Number Description Price SNMP SNMP Adapter with cables $400 CIFK AS/400 Cable $180 SFWR UPS Management Software for Windows $99 SFWR UPS Management Software for Unix $250
5 Battery Information Runtime Chart Battery Option 100% Load 75% Load 50% Load 25% Load (1) BP096B1250, (8) BBAT m 18m 33m 1h25m (2) BP096B m 50m 1h25m 2h59m 16kVA (3) BP096B m 1h25m 2h07m 5h01m (4) BP096B1250 1h25m 1h53m 2h59m 6h51m (5) BP096B1250 1h47m 2h28m 3h54m 8h47m (1) BP120B1250, (10) BBAT m 18m 33m 1h25m (2) BP120B m 50m 1h25m 2h59m 20kVA (3) BP120B m 1h25m 2h07m 5h01m (4) BP120B1250 1h25m 1h53m 2h59m 6h51m (5) BP120B1250 1h47m 2h28m 3h54m 8h47m Battery Option Components Battery Option Cabinets Batteries Battery Interconnect Kit BP096B1250 (1) BP (8) BBAT MCAK BP120B1250 (1) BP (10) BBAT MCAK-10010
CTO Configuration Guide
CTO Configuration Guide FER5GDE October 208 Table of Contents Eaton Ferrups Ferrups 60Hz RM Series Ferrups CTO Worksheet..2 Ferrups 60Hz Rackmount Series Quick Reference Sheet.. 3 Ferrups CTO Details FES.4kVA...4k-
More informationPW9170+ CTO Configuration Guide CTO Configuration Guide
CTO Configuration Guide Eaton 9170+ UPS 9170PCG January 1, 2018 Configuring Your PW9170+ UPS PW9170+ chassis s must be ordered using a Configure To Order (CTO) Number that reflects the cabinet style, isolation
More informationUninterruptible Power Supplies
Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA
More informationInnovative POWER Solutions
Innovative POWER Solutions ISO 9001 : 2008 REGISTERED QUALITY MANAGEMENT SYSTEM PANTROL, INC. INVITES YOU TO REVIEW A SAMPLING OF OUR STANDARD PRODUCTS LINE. FOR SPECIAL APPLICATIONS OR CONFIGURATIONS
More informationSmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output
SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,
More informationAxxium Pro - iseries (AS/400) Integration
Axxium Pro - iseries (AS/400) TOPICS Installation Startup Optional Features Help/Resources www.invensys-power.com/ibm-ups/9910solutions.html, ProPrep - iseries Dec, 2000 Page 1 Obtain a copy of Axxium
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationSmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out
SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)
More informationConfigurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English
Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................
More informationNOTE: Beginning LATE May 2005, the HP R5500 XR UPS is qualified for use on HP9000 and Integrity Servers. Description
Overview NOTE: Beginning LATE May 2005, the HP R5500 XR UPS is qualified for use on HP9000 and Integrity Servers. Description HP UPS Solutions Product Number VA Watts Family Supported Software J4367A 3.0
More informationAdvanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units
GE Energy Industrial Solutions GEH-704 Installation Instructions Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units
More informationRedefining Power Quality
Redefining Power Quality POWER PROTECTION POWER FILTRATION POWER MANAGEMENT DATA + ANALYTICS BATTERY BACKUP RESIDENTIAL Product Catalog E N G I N E E R E D W I T H YO U R B U S I N E S S I N M I N D With
More informationALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION
ALL PSU Ltd Unit D6 Laser Quay, Culpeper Close Medway City Estate, Rochester, Kent, ME2 4HU Phone: 01634-725527 Fax: 01634-739111 E-mail: sales@allpsu.co.uk Web: www.allpsu.co.uk ROTATION+ 6kVA - 10kVA
More informationPowerware 9315 Hot Sync Parallel Capacity System Bypass Module (SBM)
Powerware 9315 Hot Sync Parallel Capacity System Bypass Module (SBM) Modbus Profile 164950161 Rev B Read Input Status Modbus Function Code 02 Input registers start at 10000. Register 1 On Battery 0 BOOL
More informationSmartPro 3U Rack/Tower Extended-Run UPS Line-interactive, sine wave UPS
SmartPro 3U Rack/Tower Extended-Run UPS Line-interactive, sine wave UPS Model #: SMX5000XLRT3U 5000VA 230V Sine Wave Expandable Rack/Tower UPS; all-in-one chassis requires 3 rack spaces total Battery-independent
More informationWBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH
WBS HARDWIRED SERIES 4-60KVA MAINTENANCE BYPASS SWITCH Man 440 Issue 7 1 1. INTRODUCTION... 3 2. INSTALLATION... 3 2.1 Connection of the Mains Supply... 3 2.2 Connection of the Input to the UPS... 4 2.3
More informationPANELITE ENCLOSURE LIGHTS OVERVIEW
SPEC-00581 H763.422.2211 763.422.2600 ELECTRICAL LIGHTING PACKAGES ELECTRICAL LIGHTING PACKAGES PANELITE ENCLOSURE LIGHTS OVERVIEW FEATURES Slim profile allows light to be tucked up out of the way for
More informationSmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU6000RT3UHV 6000VA online 6U rack / tower UPS (3U Power Module + 3U Battery
More informationModel BB9 RS-232 Multi-Drop Box. Operating Bulletin. Innovative Flow and Pressure Solutions. Standard 8 pin Mini-DIN Connector
Operating Bulletin Standard 8 pin Mini-DIN Connector Model BB9 RS-232 Multi-Drop Box Innovative Flow and Pressure Solutions 6 pin Locking Industrial Connector 1 12/15/2011 Rev.1 DOC-BB9MAN-RS232 2 Alicat
More informationeserver Integration
9125 - eserver TOPICS Installation Startup Optional Features Help/Resources 9125 Prep - eserver rev April 01 Page 1 Obtain a copy of Powerware 9125 9910 Installation Guide for IBM Applications and Powerware
More informationSmartOnline Expandable Rack / Tower UPS System On-line, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System On-line, double-conversion protection for mission critical applications Model #: SU10KRT3UHV 10,000VA (10kVA) / 8,000W on-line 6U rack / tower UPS (3U Power
More informationReady Protects and provides control for basic IP needs
Power Management Axess Elite ELITE The most advanced power management, monitoring, nd protection system available Power Management IP Addressable Internal Log SX-AX15E Outlet Level SX-AX20E Outlet Level
More informationSmartOnline Hot-Swappable Modular UPS System On-line, double-conversion protection for mission critical applications
SmartOnline Hot-Swappable Modular UPS System On-line, double-conversion protection for mission critical applications Model #: SU8000RT4U 8000VA / 8kVA on-line, double-conversion, extended run, 4U all-in-one
More informationHardwired Uninterruptible Power Supply
96-01160 / rev. 1 / 08-15-11 Hardwired Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Hardwired Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs
More informationBasketball Shot Clock Set LX2180 Manual
Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents
More informationEATON Transformer Module
www.eaton.com EATON Module Quick Start Standard Features When used with standard system, EATON Module provides isolated and Step-down 0/08/0 V AC outputs. Multiple Output receptacles: 0/08/0 V AC. 86-86000-0
More informationEMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina
Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or
More informationSPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS
SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors
More informationSmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial
SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX5000XLRT3U Highlights 5kVA / 5000VA line interactive 3U rack/tower
More informationSmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch
SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch MODEL NUMBER: SU6000RT4UHVG Highlights 6kVA / 6000VA / 5400W on-line
More informationPowerware P60/61
ware 51405 9910 P60/61 Runtime and Rack Connections P60 & P61 Runtime and Rack Connections v5.ppt Battery Runtime Matrix Battery Runtime (in minutes)* Standard (Std) Watts Internal Batteries 1 EBM 2 EBMs
More informationPrestige - eserver Integration
Prestige - eserver TOPICS Installation Startup Optional Features Help/Resources PrestPrep - eserver rev Apr 01 Page 1 Obtain a copy of Powerware Prestige User s Guide from URL noted: EP5 (21H1572) U33
More informationSmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)
SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Description Tripp Lite's SU80KX (80kVA) SmartOnline Modular 3-Phase
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationHigher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile
More informationAir Flow. Three Phase UPS Installation. Installation Drawing Rev C. Top View. Side View (Both Sides Typ.) Front View.
().75" or " Conduit knockouts.5" ".5".5" Rev. B: 5//06 Rev. A: ew Air Flow ().5" or " Conduit knockouts Top View.75" 8" 5".5" Output CB CB Input CB ().5" or " Conduit knockouts.5" 68" ().75" or " Conduit
More informationSmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port
SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port MODEL NUMBER: SMART1050 Highlights 1.05kVA / 1050VA line interactive tower UPS system 120V output, Corrects brownouts and overvoltages
More informationOmniVS 230V 1500VA 940W Line-Interactive UPS, Extended Run, Tower, USB port, C13 Outlets
OmniVS 230V 1500VA 940W Line-Interactive UPS, Extended Run, Tower, USB port, C13 Outlets MODEL NUMBER: OMNIVSINT1500XL Highlights 1500VA / 1.5kVA tower 230V line interactive extended-run UPS Corrects brownouts
More informationSTATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The
More informationInternet Office UPS System - All-in-one SOHO Solution
Internet Office UPS System - All-in-one SOHO Solution MODEL NUMBER: INTERNET525U Description Tripp Lite's INTERNET525U standby UPS offers complete protection for PCs, workstations and other sensitive electronics
More informationLiebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection
Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection Liebert GXT4 UPS, 5kVA-10kVA Systems: Best Protection for Critical Network Applications Today s converged networks require increased availability
More informationProgressive Industries, Inc. EMS Electrical Management System
Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.
More informationSmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets
SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 14U Rack/Tower, 208/120V or 240/120V NEMA & C19 outlets MODEL NUMBER: SU20KRT-1TF Description Tripp Lite SU20KRT-1TF 20,000VA / 20kVA / 18,000 watt
More informationLiebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity
Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today
More informationElectrical Management System (EMS) EMS-HW30C & EMS-HW50C
Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationEMS-PT30X & EMS-PT50X
Electrical Management System (EMS) EMS-PT30X & EMS-PT50X Installation & Operating Guide for: Model EMS-PT30X Rated at 120V/30A and Model EMS-PT50X Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationSmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System
SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower
More information1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6
Product Description LanPro 31 Contents: 1. Introduction...2 2. Functional explanation...2 2.1 Principles of Operation...2 2.2 Normal Conditions...3 2.3 Mains Failure...3 2.4 Bypass operation...4 3. External
More informationGXT 2U Configuration Program
POWER AVAILABILITY GXT 2U Configuration Program USER MANUAL Version 1.6 Table Of Contents TABLE OF CONTENTS Introduction and Requirements...3 Configuration Program Installation...4 Establishing Communication
More information3 Uninterruptible Power Systems
S5K Modular Series Uninterruptible Power Systems (UPS) This easily upgraded and flexible UPS provides the protection you want, when you need it. The 5K Modular is scalable from 4 to 20 kva, offering many
More informationADDENDUM FOR 20, 27, & 28 OPTIONS
ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and
More informationSmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial
SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD3U Description Tripp Lite Smart Online UPS systems
More informationOmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial
OmniSmart 120V 330VA 225W UL 60601-1 Medical Grade Line-Interactive UPS, Tower, DB9 Serial MODEL NUMBER: OMNISMART350HG Highlights 330VA line interactive tower UPS Maintains sine-wave 120V nominal output
More informationSMARTONLINE E3 UPS SYSTEMS
SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,
More informationThe quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.
7011A_JAN_2011_REVISED_88776_A_7011A 2/1/11 12:57 PM Page 1 7011A Series (6kVA to ) Advantages UNINTERRUPTIBLE POWER SUPPLIES Advanced IGBT technology in both the rectifier and inverter True double conversion
More informationInstruction Manual. Electrical Management System (EMS) EMS-PT30X & EMS-PT50X
Instruction Manual Electrical Management System (EMS) EMS-PT30X & EMS-PT50X EMS-PT50X EMS-PT30X 2 ProgressiveIndustries.net 919-267-6964 Features High/Low Voltage Protection: The EMS continuously monitors
More informationSmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial
SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial MODEL NUMBER: SU3000RTXLCD2U Description Tripp Lite Smart Online UPS systems
More informationSmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules
SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules MODEL NUMBER: SVX90KM3P5B Highlights 90kVA/90kW Modular, Scalable,
More informationSmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SVTX Series 3-Phase 380/400/415V 30kVA 27kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT30KX Highlights On-line double-conversion topology, VFI operation
More informationSmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1500XLRT2U Highlights 1.5kVA / 1500VA / 1350W line interactive 2U
More informationSmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, V Hardwire output
SmartOnline 6kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V Hardwire output MODEL NUMBER: SU6000RT3UHVXL Highlights 6000VA / 6kVA / 4200W on-line double-conversion UPS 200/208/220/230/240V
More informationOmniSmart 120V 1400VA 940W Line-Interactive UPS, Tower, USB port
OmniSmart 120V 1400VA 940W Line-Interactive UPS, Tower, USB port MODEL NUMBER: OMNISMART1400 Highlights 1400VA / 1.4kVA tower 120V line interactive UPS Corrects brownouts and overvoltages from 75V to 147V
More informationSmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMX2200XLRT2U Highlights 2.2kVA / 2200VA / 1920W line interactive
More informationSmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial
SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline
More informationSmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America
SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Description Tripp Lite's SU40K (40kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line
More informationInk-Dot Series II Driver
Instruction Sheet P/N 766B Ink-Dot Series II Driver Introduction See Figure. Ink-Dot Series II controllers can have from one to three driver modules. Any existing controller can easily be retrofit with
More informationRackmount Power Distribution - Professional 15 Amp. Rackmount Power Distribution - Professional 20 Amp
Retail Pricing Rackmount Power Distribution - Professional 15 Amp ETA-C15D AP-GNL18 Professional 10 Outlet 15A Rackmount Power Distribution with Single Retractable Rack Light & Digital Voltmeter - Dual
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationModel #: SU1500RTXL2U
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SU1500RTXL2U Smart Online Expandable Rack/Tower UPS System - Online, double-conversion
More informationPrestige - eserver Integration
Prestige - eserver TOPICS Preparation Startup Optional Features Help/Resources PrestInstall - eserver rev Apr 01 Page 1 Step 1 - Remove UPS equipment from Cartons UPS must be placed near the installation
More informationSmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch
SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline
More informationBC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets
BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets MODEL NUMBER: BCPRO1400 Highlights 1400VA / 1.4kVA tower 120V standby UPS Maintains AC output during power failures USB port, Front panel
More informationLED Tape Light Radiance Series
LED Radiance Series ing with Protective Micro Waterproof Coating IP65 rated Medium Output 120 lumens per foot (395/M) at 3000K 58 Tasking.com Customer Service: 800.445.6404 Design Services: 866.848.9094
More informationUninterruptible Power Systems
Uninterruptible Power s 2 S5K Modular Series On-Line Uninterruptible Power s (UPS) The 5K Modular is scalable from 4 to 20 kva, offering many flexible options by adding a few standard modules. Designed
More informationUser Guide Chevrolet Volt
User Guide Chevrolet Volt Accessory Power Control Module General Motors Part Numbers 24262765 and 24261518 Copyright 2015 EVTV LLC 0 INTRODUCTION The Accessory Power Control Module, sometimes referred
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationLiebert. GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications
Liebert GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications LIEBERT GXT3 Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today s converged networks require
More informationEMS Electrical Management System
EMS Electrical Management System Complete Operating & Warranty Guide EMS-PT30C Rated at 120 Volts/30 Amps Manufactured & Warranted by Progressive Industries Sold & Serviced by VIP Enterprises 428 Childers
More informationWho Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?
Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment? A Network Power Management White Paper Who Needs Remote Power Management for Power Distribution,
More informationEaton UPS. Product Snapshot. Powerware series
Powerware series Eaton 9170+ UPS Features N+X redundancy for both power and logic eliminates systemlevel single point-of-failure Easily scalable to adapt to changing IT environments by simply adding power
More informationXTREME POWER CONVERSION THE VALUE LEADER IN POWER PROTECTION
CONVERSION THE VALUE LEADER IN POWER PROTECTION Xtreme Power is a global manufacturer of power quality and data center solutions Xtreme Power manufactures UPS from 400VA to 40kVA Designs, engineers, and
More informationSolar Mounting Made Simple. Enclosures & Racks Master Price List Effective October 12th, 2009
Solar Mounting Made Simple Enclosures & Racks Master Price List Effective October 12th, 2009 Introduction Thank you for choosing IronRidge s Battery Enclosures and Rack solutions. This catalog provides
More informationDell Smart-UPS 1,500 3,000 VA
Dell Smart-UPS,00,000 VA 0 V Advanced line interactive power protection for servers and network equipment Reliable. Intelligent. Efficient. Manageable. Engineered by APC by Schneider Electric, the Dell
More informationSmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial
SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial MODEL NUMBER: SU3000RTXL3UHV Highlights 3000VA / 3kVA / 2400 watt on-line double-conversion
More informationThis 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount
More informationPremium Online Series
Premium Online Series UPS backup power systems backup protection with double conversion that isolates and conditions output power for clean, consistent, reliable power features: Permanent connection to
More informationCAUTION READ CAREFULLY
Docking Drawer Install Manual for DD 21 + 24 Slim Applicable Models: 0290-00030, 0290-00030W, 0290 00031, 0290 00031W 0230-00004. r5 10/21/2015 CAUTION READ CAREFULLY Failure to follow these instructions
More informationSmartOnline 208/240V 10kVA 9kW Double- Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA
SmartOnline 208/240V 10kVA 9kW Double- Conversion UPS, 6U, Extended Run, Network Card Slot, USB, DB9, Bypass Switch, NEMA MODEL NUMBER: SU10000RT3U Highlights 10kVA / 10,000VA / 9000W online double-conversion
More informationAPC Symmetra LX. GUIDE SPECIFICATIONS FOR 4kVA-16kVA Uninterruptible Power System
APC Symmetra LX GUIDE SPECIFICATIONS FOR 4kVA-16kVA Uninterruptible Power System PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous duty, singlephase,
More informationSmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications
SmartOnline Expandable Rack/Tower UPS System On-line, double-conversion protection for mission-critical applications Model #: SU2200RTXL2U 2200VA on-line 2U rack / tower UPS Enhanced serial communications
More informationBeacon Power Supply Operating and Installation Instruction Manual
Beacon Power Supply Operating and Installation Instruction Manual Model: BNx000 Page 1 of 27 I. Warnings and Notices I. WARNING - To reduce the risk of fire or electric shock, do not expose this product
More informationSTANDALONE PCI INTERFACE PACKAGE
instrumentation and software for research STANDALONE PCI INTERFACE PACKAGE USER S MANUAL DOC 039 Rev 1.3 Copyright 2013 All Rights Reserved Med Associates Inc. P.O. Box 319 St. Albans, Vermont 05478 Phone:
More informationUPS Series. features: uninterruptible power supply. what great systems are built on.
uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation
More informationOwner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices
Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com
More informationSmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9
SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9 MODEL NUMBER: SMX5000XLRT3U Highlights 5kVA / 5000VA line interactive 3U rack/tower UPS; Sine
More information3 Uninterruptible Power Systems
S5K Modular Series On-Line Uninterruptible Power s (UPS) This easily upgraded and flexible UPS provides the protection you want, when you need it. The 5K Modular is scalable from 4 to 20 kva, offering
More informationEMS Electrical Management System
EMS Electrical Management System Complete Installation/Operating & Warranty Guide EMS-HW50C Rated at 240 Volts/50 Amps Manufactured & Warranted by Progressive Industries Sold & Serviced by VIP Enterprises
More informationSmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)
SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Highlights 80,000 VA (80kVA) 3-phase tower UPS N+1 redundant modular
More informationSmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9
SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9 MODEL NUMBER: SU3000RTXLCD3N Highlights Zero transfer time suitable for advanced
More informationOwner s Manual Revision 4.01 Option 1
Owner s Manual Revision 4.01 Option 1 Special Version of the SW series Inverter / Charger for Motor Coach Applications Part # 2031-7 (Supplement to Normal Manual) Effective Date: April 17, 1996 Trace Engineering
More information