R3&A Limited, Cobourg, ON
|
|
- Tamsyn Butler
- 6 years ago
- Views:
Transcription
1 R3&A imited, Cobourg, ON ightning and Surge Protection Devices for North America
2 Easy Choice POWER SUPPY SYSTEMS Main distribution board (Category C) Class I ightning current arrester Subdistribution board (Category B) Class II Surge arrester Terminal equipment (Category A) Class III Surge arrester 120 V 2 wires + Ground (single phase) N Ground 1 2 ' ' DG MOD 150 DG MOD 150 DEHNrail DR MOD 150 equipment 120 V N /PEN N /PEN 3 4 EBB 2 x DBM (Part No ) 1 x MVS 1 4 (Part No ) 2 x DG S 150 (Part No ) 1 x MVS 1 2 (Part No ) or 2 x DG S 150 FM (Part No ) 1 x MVS 1 2 (Part No ) 1 x DR M 2P 150 (Part No ) or 1 x DR M 2P 150 FM (Part No ) 120 V / 240 V 3 wires + Ground (split phase) 1 2 N Ground ' ' ' DG MOD 150 DG MOD 150 DG MOD 150 DEHNrail DR MOD 150 equipment 120 V DEHNrail DR MOD 150 equipment 240 V N /PEN N /PEN N /PEN EBB 3 x DBM (Part No ) 1 x MVS 1 6 (Part No ) 3 x DG S 150 (Part No ) 1 x MVS 1 3 (Part No ) or 3 x DG S 150 FM (Part No ) 1 x MVS 1 3 (Part No ) 1 x DR M 2P 150 (Part No ) or 1 x DR M 2P 150 FM (Part No ) 1 x DR M 2P 255 (Part No ) or 1 x DR M 2P 255 FM (Part No ) 2
3 POWER SUPPY SYSTEMS Easy Choice Main distribution board (Category C) Class I ightning current arrester Subdistribution board (Category B) Class II Surge arrester Terminal equipment (Category A) Class III Surge arrester 120 V / 208 V (Y) 4 wires + Ground N Ground 1 2 ' ' ' ' DG MOD 150 DG MOD 150 DG MOD 150 DG MOD 150 DEHNrail DR MOD 150 equipment 120 V N /PEN N /PEN N /PEN N /PEN 3 4 EBB 4 x DBM (Part No ) 1 x MVS 1 8 (Part No ) 4 x DG S 150 (Part No ) 1 x MVS 1 4 (Part No ) or 4 x DG S 150 FM (Part No ) 1 x MVS 1 4 (Part No ) 1 x DR M 2P 150 (Part No ) or 1 x DR M 2P 150 FM (Part No ) 277 V / 480 V (Y) 4 wires + Ground N Ground DG MOD 385 DG MOD 385 DG MOD 385 DG MOD 385 N / N/ N / N/ N / N/ N / N/ EBB 4 x DBM (Part No ) 1 x MVS 1 8 (Part No ) 4 x DG S 385 (Part No ) 1 x MVS 1 4 (Part No ) or 4 x DG S 385 FM (Part No ) 1 x MVS 1 4 (Part No ) 3
4 4 NOTES
5 POWER SUPPY SYSTEMS SPD Type 1 according to EN SPD Class I according to IEC For protection of low voltage consumer s installations against surges even at direct lightning strokes. For use in the lightning protection zones concept at boundaries 0 A 1. Encapsulated RADAX Flow spark gap with high follow current limitation No tripping of 32 A g/gg fuses up to short-circuit currents of 50 ka rms Discharge capacity up to 25 ka (10/350 µs) Coordinated directly with surge protective device without additional cable length ow voltage protection level DEHNbloc Maxi Coordinated ightning Current Arrester Double terminals for series connection Multifunctional connection for conductors and busbars DEHNbloc Maxi 1 135: DEHNbloc Maxi 1 320: Coordinated, single-pole lightning current arrester with high follow current limitation for U C = 135 V Coordinated, single-pole lightnint current arrester with high follow current limitation for U C = 320 V The coordinated lightning current arresters of the DEHNbloc Maxi product family adapt themselves to every kind of application. Whether being used in an exposed position or in rough industrial applications: DEHNbloc Maxi always offers the right solution. The single-pole devices are originally coordinated with the approved surge arresters of the Red/ine family. Independent from cable lengths and without requiring additional decoupling coils, the surge protection concept can be adapted individually to all conditions at the installation. DEHNbloc Maxi devices provide patented technology of encapsulated creepage discharge spark gaps and RADAX Flow follow current limitation. Special safety distances from busbars or equipment belong to the past as well as tripped backup fuses due to lacking selectivity between the protective device and overcurrent protection. This ensures maximum system availability. For indicating the presence of phase voltages and readiness for operation on site, DEHNbloc Maxi type DBM has an integrated operating voltage indicator. DEHNbloc Maxi devices can also be used for signalling readiness for operation of the equipment as well as presence of operating voltage to a superior control system by remote signalling contact. Using the double terminals of DEHNbloc Maxi devices, which are suitable for all types of conductors, allows to realise a series connection in a space- and cost-saving way up to nominal currents of 125 A, as preferred by standard IEC The multifunctional terminal is suitable for simultaneous connection of conductors and busbars. This allows for easy wiring with other DIN rail mounted devices. 5
6 DEHNbloc Maxi DEHNbloc Maxi POWER SUPPY SYSTEMS N /PEN Basic circuit diagram DBM Dimension drawing DBM DBM 1 135: Coordinated, single-pole lightning current arrester with high follow current limitation for U C = 135 V DBM SPD according to EN Type 1 SPD according to IEC Class I Max. continuous ac voltage U C 135 V ightning impulse current (10/350 µs) I imp 25 ka Voltage protection level U P 1.5 kv Follow current extinguishing capability ac I fi 50 ka rms Follow current limitation / Selectivity no tripping of a 32 A g/gg fuse up to 50 ka rms (prosp.) Response time t A 100 ns Max. backup fuse () up to I K = 25 ka rms (t a 0.2 s) 315 A g/gg Max. backup fuse () at I K = 50 ka rms (t a 5 s) 250 A g/gg Max. backup fuse () up to I K > 50 ka rms 200 A g/gg Max. backup fuse (- ) 125 A g/gg TOV voltage U T 335 V / 5 sec. Operating temperature range (parallel connection) T UP -40 C C Operating temperature range (series connection) T US -40 C C Cross-sectional area (,,, N /PEN) min. 10 mm 2 solid/flexible [AWG #7] Cross-sectional area (, ) max. 50 mm 2 stranded/35 mm 2 flexible [AWG #0/1] Cross-sectional area (, N /PEN) max. 35 mm 2 stranded/25 mm 2 flexible [AWG #2] Mounting on 35 mm DIN rail acc. to EN Enclosure material red thermoplastic, U 94 V-0 Degree of protection IP 20 Dimension 2 mods., DIN Type DBM Part No Packing unit 1 pc(s) 6
7 POWER SUPPY SYSTEMS DEHNbloc Maxi DEHNbloc Maxi 320 N /9 N/9 Dimension drawing DBM Basic circuit diagram DBM DBM 1 320: Coordinated, single-pole lightning current arrester with high follow current limitation for U C = 320 V DBM SPD according to EN Type 1 SPD according to IEC Class I Max. continuous ac voltage U C 320 V ightning impulse current (10/350 µs) I imp 20 ka Voltage protection level U P 2.5 kv Follow current extinguishing capability ac I fi 50 ka rms Follow current limitation / Selectivity no tripping of a 32 A g/gg fuse up to 50 ka rms (prosp.) Response time t A 100 ns Max. backup fuse () up to I K = 50 ka rms 250 A g/gg Max. backup fuse () up to I K > 50 ka rms 160 A g/gg Max. backup fuse (- ) 125 A g/gg TOV voltage U T 425 V / 5 sec. Operating temperature range (parallel connection) T UP -40 C C Operating temperature range (series connection) T US -40 C C Cross-sectional area (,, N/9,N /9) min. 10 mm 2 solid/flexible [AWG #7] Cross-sectional area (, N/9) max. 50 mm 2 stranded/35 mm 2 flexible [AWG #0/1] Cross-sectional area (, N /9) max. 35 mm 2 stranded/25 mm 2 flexible [AWG #2] Mounting on 35 mm DIN rail acc. to EN Enclosure material red thermoplastic, U 94 V-0 Degree of protection IP 20 Dimension 2 mods., DIN Type DBM Part No Packing unit 1 pc(s). 7
8 S / S FM Single-pole pluggable Surge Arrester Surge arrester for universal use, consisting of a base part and plug-in protective component High discharge capacity due to powerful zinc oxide varistor High reliability due to Thermo Dynamic Control SPD monitoring device Energy-coordinated within the Red/ine product family Operating state/fault indication by mark in the inspection window Small (modular) design according to DIN Multifunctional terminals for connection of conductors and busbars Easy exchange of protection modules with module releasing button POWER SUPPY SYSTEMS SPD Type 2 according to EN SPD Class II according to IEC For protection of low-voltage consumer s installations against surges. For use in the lightning protection zones concept at boundaries 0 B 1 and higher. S...: S... FM: Pluggable surge arrester, consisting of a base part and plug-in protection module With remote signalling contact for monitoring device (floating changeover contact) The universal features characterise the single-pole devices of the S product family. Whether as a single device or in combination with other devices the S surge arresters always ensure a proper protective circuit. The modern Red/ine family design and its universal features ensure safety and easy application for the user. The module releasing button also characterises the devices of the S series, like the approved Thermo Dynamic Control SPD monitoring device with dual tripping performance. Experience of decades with the application of surge arresters worldwide has further improved the latest generation compared to the previous types. The module locking system, which is unique for surge protective devices, fixes the protection modules to the base part. Neither vibrations during transport nor the enourmous forces of currents during discharges can loosen the protection modules. And still, the modules can be easily exchanged without tools, if necessary. This is ensured by the user-friendly releasing button of the protection modules. ike with all surge arresters, the users of S can rely on the dual monitoring device Thermo Dynamic Control. This provides maximum safety of the devices, even under unfavourable environmental conditions. Readiness for operation of S is indicated by the visual indicator with green and red marks. Apart from the standard visual indicator, S... FM has a 3-pole terminal for remote signalling.with the remote signalling contact, being a floating changeover contact, the remote signal can be used as a break or make contact, according to circuit concept. The S surge arresters are supplied with multifunctional terminals for connection of conductors and busbars. This allows for easy wiring in connection with other DINrail mountable devices. A series connection according to IEC , which is optimal for protection, can therefore be performed in many applications. In order to avoid a wrong supplying by the installer or user when exchanging the protection modules, every base part and protection module has a mechanical coding set by the manufacturer. 8
9 POWER SUPPY SYSTEMS S / S FM S... Basic circuit diagram DG S... Dimension drawing DG S... DG S...: Single-pole pluggable surge arrester consisting of a base part and plug-in protection module DG S 75 DG S 150 DG S 275 DG S 320 DG S 385 DG S 440 DG S 600 SPD according to EN Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 SPD according to IEC Class II Class II Class II Class II Class II Class II Class II Max. continuous ac voltage U C 75 V 150 V 275 V 320 V 385 V 440 V 600 V Max. continuous dc voltage U C 100 V 200 V 350 V 420 V 500 V 585 V 600 V Nominal discharge current (8/20 µs) I n 10 ka 15 ka 20 ka 20 ka 20 ka 20 ka 15 ka Max. discharge current (8/20 µs) I max 40 ka 40 ka 40 ka 40 ka 40 ka 40 ka 30 ka Voltage protection level U P 0.4 kv 0.7 kv 1.25 kv 1.5 kv 1.75 kv 2 kv 2.5 kv Voltage protection level at 5 ka U P 0.35 kv 0.55 kv 1 kv 1.2 kv 1.35 kv 1.7 kv 2 kv Suppressed voltage rating SVR 330 V 500 V 800 V 900 V 1200 V 1200 V 1800 V Response time t A 25 ns 25 ns 25 ns 25 ns 25 ns 25 ns 25 ns Max. mains-side overcurrent protection 125 A g/gg 125 A g/gg 125 A g/gg 125 A g/gg 125 A g/gg 125 A g/gg 100 A g/gg Short circuit withstand capability at max. mains-side overcurrent protection 50 ka rms 50 ka rms 50 ka rms 25 ka rms 25 ka rms 25 ka rms 25 ka rms TOV voltage U T 335 V / 5 sec. 335 V / 5 sec. 580 V / 5 sec. Operating temperature range T U -40 C C -40 C C -40 C C -40 C C -40 C C -40 C C -40 C C Cross-sectional area (min.) 1.5 mm 2 solid/flexible [AWG #15] Cross-sectional area (max.) 35 mm 2 stranded/25 mm 2 flexible [AWG #2] Mounting on 35 mm DIN rail acc. to EN Enclosure material red thermoplastic, U 94 V-0 Degree of protection IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 Dimension 1 mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN Type DG S 75 DG S 150 DG S 275 DG S 320 DG S 385 DG S 440 DG S 600 Part No Packing unit 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 9
10 S / S FM S... FM POWER SUPPY SYSTEMS Dimension drawing DG S... FM Basic circuit diagram DG S... FM DG S... FM: Single-pole pluggable surge arrester consisting of a base part and plug-in protection module; with floating remote signalling contact DG S 75 FM DG S 150 FM DG S 275 FM DG S 320 FM DG S 385 FM DG S 440 FM DG S 600 FM SPD according to EN Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 SPD according to IEC Class II Class II Class II Class II Class II Class II Class II Max. continuous ac voltage U C 75 V 150 V 275 V 320 V 385 V 440 V 600 V Max. continuous dc voltage U C 100 V 200 V 350 V 420 V 500 V 585 V 600 V Nominal discharge current (8/20 µs) I n 10 ka 15 ka 20 ka 20 ka 20 ka 20 ka 15 ka Max. discharge current (8/20 µs) I max 40 ka 40 ka 40 ka 40 ka 40 ka 40 ka 30 ka Voltage protection level U P 0.4 kv 0.7 kv 1.25 kv 1.5 kv 1.75 kv 2 kv 2.5 kv Voltage protection level at 5 ka U P 0.35 kv 0.55 kv 1 kv 1.2 kv 1.35 kv 1.7 kv 2 kv Suppressed voltage rating SVR 330 V 500 V 800 V 900 V 1200 V 1200 V 1800 V Response time t A 25 ns 25 ns 25 ns 25 ns 25 ns 25 ns 25 ns Max. mains-side overcurrent protection 125 A g/gg 125 A g/gg 125 A g/gg 125 A g/gg 125 A g/gg 125 A g/gg 100 A g/gg Short circuit withstand capability at max. mains-side overcurrent protection 50 ka rms 50 ka rms 50 ka rms 25 ka rms 25 ka rms 25 ka rms 25 ka rms TOV voltage U T 335 V / 5 sec. 335 V / 5 sec. 580 V / 5 sec. Operating temperature range T U -40 C C -40 C C -40 C C -40 C C -40 C C -40 C C -40 C C Cross-sectional area (min.) 1.5 mm 2 solid/flexible [AWG #15] Cross-sectional area (max.) 35 mm 2 stranded/25 mm 2 flexible [AWG #2] Mounting on 35 mm DIN rail acc. to EN Enclosure material red thermoplastic, U 94 V-0 Degree of protection IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 Dimension 1 mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN Type of remote signalling contact changeover contact Switching capacity ac 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A Switching capacity dc 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A Cross-sectional area for remote signalling terminals max. 1.5 mm 2 solid/flexible [AWG #16] Type DG S 75 FM DG S 150 FM DG S 275 FM DG S 320 FM DG S 385 FM DG S 440 FM DG S 600 FM Part No Packing unit 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 10
11 POWER SUPPY SYSTEMS SPD Type 3 according to EN SPD Class III according to IEC For protecting the power supply of industrial electronic devices against surges in switchgear installations. DEHNrail modular Two-pole pluggable Surge Arrester Two-pole surge arrester consisting of a base element and plug-in protection module High discharge capacity due to powerful zinc-oxide-varistor/spark-gap combination Energy-coordinated within the Red/ine product family Operating state/fault indication by mark in the inspection window Small (modular) design according to DIN Easy exchange of protection modules with module releasing button DEHNrail M 2P...: DEHNrail M 2P... FM: Two-pole surge arrester consisting of a base element and plug-in protection module With remote signalling contact for monitoring device (floating changeover contact) The new modular devices of the DEHNrail M product family impress the users with their high performance parameters and new clear Red/ine design. The device combines safety and easy handling in only one module to a convincing synergy. The low voltage protection level as well as the comprehensive protection against common-mode and differential-mode interferences are designed for protection of industrial terminal electronic devices in an optimal way. The design of the devices with input and output terminals for series connection and the protective circuit designed for high load currents underline this concept. If the protective circuit is overloaded despite of the powerful characteristics of the devices, the module releasing button allows for quick exchanging of the protection module. Apart from the standard visual indication by the green and red marking, type DEHNrail M... FM has a 3-pole terminal for remote signalling. As the remote signalling contact is a floating changeover contact, the remote signal can be used as break or make contact, according to circuit concept. The very compact design of the DEHNrail M devices includes the distinctive Y protection circuit and the combined SPD control and disconnector. The coding integrated into the base part and protection module prevents wrong supplying by the installer or user. The new module locking system of the DEHNrail M product family is unique for surge protective devices. It connects the surge protection module tightly with the base part of the SPD. Neither vibrations during transport nor the electromagnetic forces of discharges can loosen this connection. 11
12 DEHNrail modular DEHNrail M 2P... POWER SUPPY SYSTEMS 1 2 ϑ ϑ 3 4 Basic circuit diagram DR M 2P... Dimension drawing DR M 2P... DR M 2P...: Two-pole surge arrester consisting of a base element and plug-in protection module DR M 2P 30 DR M 2P 60 DR M 2P 75 DR M 2P 150 DR M 2P 255 SPD according to EN Type 3 Type 3 Type 3 Type 3 Type 3 SPD according to IEC Class III Class III Class III Class III Class III Nominal ac voltage U N 24 V 48 V 60 V 120 V 230 V Max. continuous ac voltage U C 30 V 60 V 75 V 150 V 255 V Max. continuous dc voltage U C 30 V 60 V 75 V 150 V 255 V Nominal load current ac I 25 A 25 A 25 A 25 A 25 A Nominal discharge current (8/20 µs) [-N] I n 1 ka 1 ka 2 ka 2 ka 3 ka Nominal discharge current (8/20 µs) [+N-PE] I n 2 ka 2 ka 4 ka 4 ka 5 ka Combined impulse [-N] U OC 2 kv 2 kv 4 kv 4 kv 6 kv Combined impulse [+N-PE] U OC 4 kv 4 kv 8 kv 8 kv 10 kv Suppressed voltage rating [-] SVR 330 V 330 V 330 V 600 V 900 V Suppressed voltage rating [-G] SVR 700 V 800 V 800 V 700 V 1500 V Voltage protection level [-N] U P 180 V 350 V 400 V 640 V 1250 V Voltage protection level [/N-PE] U P 630 V 730 V 730 V 800 V 1500 V Response time [-N] t A 25 ns 25 ns 25 ns 25 ns 25 ns Response time [/N-PE] t A 100 ns 100 ns 100 ns 100 ns 100 ns Max. mains-side overcurrent protection Short circuit withstand capability at 25 A g/gg or B 25 A mains-side overcurrent protection with 25 A g/gg 6 ka rms 6 ka rms 6 ka rms 6 ka rms 6 ka rms TOV voltage [-N] U T 335 V / 5 sec. TOV voltage [/N-PE] (I) U T 400 V / 5 sec. TOV voltage [+N-PE] (II) U T 1200 V + U 0 / 200 ms Operating temperature range T U -40 C C -40 C C -40 C C -40 C C -40 C C Cross-sectional area (min.) 0.5 mm 2 solid/flexible [AWG #20] Cross-sectional area (max.) 4 mm 2 stranded/2.5 mm 2 flexible [AWG #11] Mounting on 35 mm DIN rail acc. to EN Enclosure material red thermoplastic, U 94 V-0 Degree of protection IP 20 IP 20 IP 20 IP 20 IP 20 Dimension 1 mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN Type DR M 2P 30 DR M 2P 60 DR M 2P 75 DR M 2P 150 DR M 2P 255 Part No Packing unit 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 12
13 POWER SUPPY SYSTEMS DEHNrail modular DEHNrail M 2P... FM 1 2 ϑ ϑ Dimension drawing DR M 2P... FM Basic circuit diagram DR M 2P... FM DR M 2P... FM: Two-pole surge arrester consisting of a base element and plug-in protection module; with floating remote signalling contact DR M 2P 30 FM DR M 2P 60 FM DR M 2P 75 FM DR M 2P 150 FM DR M 2P 255 FM SPD according to EN Type 3 Type 3 Type 3 Type 3 Type 3 SPD according to IEC Class III Class III Class III Class III Class III Nominal ac voltage U N 24 V 48 V 60 V 120 V 230 V Max. continuous ac voltage U C 30 V 60 V 75 V 150 V 255 V Max. continuous dc voltage U C 30 V 60 V 75 V 150 V 255 V Nominal load current ac I 25 A 25 A 25 A 25 A 25 A Nominal discharge current (8/20 µs) [-N] I n 1 ka 1 ka 2 ka 2 ka 3 ka Nominal discharge current (8/20 µs) [+N-PE] I n 2 ka 2 ka 4 ka 4 ka 5 ka Combined impulse [-N] U OC 2 kv 2 kv 4 kv 4 kv 6 kv Combined impulse [+N-PE] U OC 4 kv 4 kv 8 kv 8 kv 10 kv Suppressed voltage rating [-] SVR 330 V 330 V 330 V 600 V 900 V Suppressed voltage rating [-G] SVR 700 V 800 V 800 V 700 V 1500 V Voltage protection level [-N] U P 180 V 350 V 400 V 640 V 1250 V Voltage protection level [/N-PE] U P 630 V 730 V 730 V 800 V 1500 V Response time [-N] t A 25 ns 25 ns 25 ns 25 ns 25 ns Response time [/N-PE] t A 100 ns 100 ns 100 ns 100 ns 100 ns Max. mains-side overcurrent protection Short circuit withstand capability at 25 A g/gg or B 25 A mains-side overcurrent protection with 25 A g/gg 6 ka rms 6 ka rms 6 ka rms 6 ka rms 6 ka rms TOV voltage [-N] U T 335 V / 5 sec. TOV voltage [/N-PE] (I) U T 400 V / 5 sec. TOV voltage [+N-PE] (II) U T 1200 V + U 0 / 200 ms Operating temperature range T U -40 C C -40 C C -40 C C -40 C C -40 C C Cross-sectional area (min.) 0.5 mm 2 solid/flexible [AWG #20] Cross-sectional area (max.) 4 mm 2 solid/2.5 mm 2 flexible [AWG #11] Mounting on 35 mm DIN rail acc. to EN Enclosure material red thermoplastic, U 94 V-0 Degree of protection IP 20 IP 20 IP 20 IP 20 IP 20 Dimension 1 mod., DIN mod., DIN mod., DIN mod., DIN mod., DIN Type of remote signalling contact changeover contact changeover contact changeover contact changeover contact changeover contact Switching capacity ac 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A 250 V/0.5 A Switching capacity dc 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A Cross-sectional area for remote signalling terminals max. 1.5 mm 2 solid/flexible [AWG #16] Type DR M 2P 30 FM DR M 2P 60 FM DR M 2P 75 FM DR M 2P 150 FM DR M 2P 255 FM Part No Packing unit 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 1 pc(s) 13
14 Accessory Parts POWER SUPPY SYSTEMS Accessory Part for S / S FM Varistor-Based Protection Module DG MOD...: Varistor-based protection module for M... and S... surge arresters Type DG MOD Nominal discharge current (8/20 μs) I n 10 ka 15 ka 20 ka 20 ka 20 ka 20 ka 15 ka Max. continuous ac voltage U C 75 V 150 V 275 V 320 V 385 V 440 V 600 V Max. continuous dc voltage U C 100 V 200 V 350 V 420 V 500 V 585 V 600 V PU Part Type pc(s) No. DG MOD DG MOD DG MOD DG MOD DG MOD DG MOD DG MOD Accessory Part for DEHNrail modular Protection Module for DEHNrail M DR MOD...: Protection module with integrated Y protection circuit Type DR MOD Nominal discharge current (8/20 μs) [-N] I n 1 ka 1 ka 2 ka 2 ka 3 ka Nominal discharge current (8/20 μs) [+N-PE] I n 2 ka 2 ka 4 ka 4 ka 5 ka Max. continuous ac voltage U C 30 V 60 V 75 V 150 V 255 V Max. continuous dc voltage U C 30 V 60 V 75 V 150 V 255 V PU Part Type pc(s) No. DR MOD DR MOD DR MOD DR MOD DR MOD
15 POWER SUPPY SYSTEMS Wiring Accessories DK 35 and STAK 2X16 DK 35 allows for changing the wiring level DK 35 supports a lightning-impulse-current-conform installation of SPD combinations STAK 2X16 allows for clamping cross sections smaller than the defined minimum clamping cross section of the surge protective device STAK 2X16 allows for EMC-optimised series connection according to IEC Realisation of an EMC-optimised series connection of lightning current and surge arresters according to IEC by means of STAK 2X16 Basic circuit diagram DK 35 DK 35: Feed-through terminal STAK 2x16: Pin-shape terminal DK 35 STAK 2X16 DK 35 STAK 2X16 Nominal ac/dc voltage U N 500 V Nominal load current ac I 100 A Test current according to EN A ightning impulse current (10/350 µs) 100 ka Backup fuse at application of arrester only 250 A g/gg Backup fuse carrying operating current 100 A g/gg Short circuit withstand capability at max. backup fuse 50 ka rms Operating temperature range T U -40 C C Cross-sectional area min. 1.5 mm 2 solid/flexible, max. 35 mm 2 stranded/25 mm 2 flexible [AWG #2] 2 x 16 mm 2 Mounting on 35 mm DIN rail acc. to EN Type of connection front (double terminal) Enclosure material red thermoplastic, U 94 V-0 Degree of protection IP 20 Dimension 1 mod., DIN Approvals, Certifications U Type DK 35 STAK 2X16 Part No Packing unit 1 pc(s) 1 pc(s) 15
16 Busbars / Modular Wiring System POWER SUPPY SYSTEMS Allows for compact connection among the arresters and with other DIN rail mounted devices MVS 2-pole, single-phase MVS 3-pole, single-phase MVS 1 2 MVS 1 3 Single-phase unit 3 3 Number of contact studs 2-pole 3-pole Max. installation width 2 mods. 3 mods. Nominal cross section 16 mm 2 16 mm 2 Type MVS 1 2 MVS 1 3 Part No Packing unit 1 pc(s) 1 pc(s) MVS 4-pole, single-phase MVS 5-pole, single-phase MVS 1 4 MVS 1 5 Single-phase unit 3 3 Number of contact studs 4-pole 5-pole Max. installation width 4 mods. 5 mods. Nominal cross section 16 mm 2 16 mm 2 Type MVS 1 4 MVS 1 5 Part No XXX Packing unit 1 pc(s) 1 pc(s) MVS 6-pole, single-phase MVS 7-pole, single-phase MVS 1 6 MVS 1 7 Single-phase unit 3 3 Number of contact studs 6-pole 7-pole Max. installation width 6 mods. 7 mods. Nominal cross section 16 mm 2 16 mm 2 Type MVS 1 6 MVS 1 7 Part No Packing unit 1 pc(s) 1 pc(s) MVS 8-pole, single-phase MVS 57-pole, singlephase MVS 1 8 MVS 1 57 Single-phase unit 3 3 Number of contact studs 8-pole 57-pole Max. installation width 8 mods. 57 mods. Nominal cross section 16 mm 2 16 mm 2 Type MVS 1 8 MVS 1 57 Part No Packing unit 1 pc(s) 1 pc(s) 16
17 POWER SUPPY SYSTEMS MVS MVS MVS Two-phase unit Number of contact studs 4-pole 7-pole 7-pole Max. installation width 5 mods. 16 mods. 22 mods. Nominal cross section 16 mm 2 16 mm 2 16 mm 2 Busbars / Modular Wiring System MVS 4-pole, two-phase MVS 7-pole, two-phase Type MVS MVS MVS Part No. 900 XXX Packing unit 1 pc(s) 1 pc(s) 1 pc(s) MVS 3 6 MVS MVS 3 57 Three-phase unit Number of contact studs 6-pole 6-pole 57-pole Max. installation width 6 mods. 8 mods. 57 mods. Nominal cross section 16 mm 2 16 mm 2 MVS 6-pole, three-phase MVS 57-pole, three-phase Type MVS 3 6 MVS 3 8 MVS 3 57 Part No Packing unit 1 pc(s) 1 pc(s) 1 pc(s) MVS Four-phase unit 3 Number of contact studs 8-pole Max. installation width 11 mods. Nominal cross section 16 mm 2 MVS 8-pole, four-phase Type MVS Part No Packing unit 1 pc(s) MVS 4 56 Four-phase unit 3 Number of contact studs 56-pole Max. installation width 56 mods. Nominal cross section 16 mm 2 MVS 56-pole, four-phase Type MVS 4 56 Part No Packing unit 1 pc(s) EB DG Single-phase unit 3 Number of contact studs 3-pole Dimension 34 x 112 x 3 mm Terminal up to 25 mm 2 EB DG 3-pole, singlephase Type EB DG Part No Packing unit 1 pc(s) 17
18 R3&A imited, Cobourg, ON ightning Protection Surge Protection Safety Equipment R3&A imited 3 Maplewood Boulevard Unit 1 Cobourg, ON Canada K9A 4J4 Phone: (1) Fax: (1) info@r3alimited.com
POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment
SPDs for low-voltage installations and equipment 13 14 Easy Choice 16 Combined SPDs Type 1 Combined 25 49 59 65 113 139 15 ÜS-Schutz Combined Easy Choice L1 L2 L3 N PE SPD (Surge arrester) SPD (Surge arrester)
More informationTechnical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:
Technical Data Circuit Protection - Surge Protection Devices Ver 1.0 CUSPD1110 Brief product description: Surge Protection Device (SPD) protect against lightning surges and man made surges such as motors,
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationSurge protection for frequency converters
Surge protection for frequency converters White Paper Contents Basic principle of a frequency converter EMC-compatible shield connection of the motor feeder cable Frequency converter with drives in LPZ
More informationIncreased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse
Increased Safety for Switchgear Cabinets CI Arresters with Backup Fuse www.dehn-international.com 1 fuse 1 2 fuse monitoring 2 3 Considerable space saving 3 Innovative solution to save space in the switchgear
More informationCoordinated Surge Protection
DEHN + SÖHNE DS641/E/10.05 The Lightning Flood Wave When lightning hits an installation, high impulse currents and impulse voltages come up within conductive systems which can be compared to an enormous
More informationwietap wietap Overvoltage Protection Tensions running high
wietap wietap Overvoltage Protection Tensions running high 2 wietap wietap Overvoltage protection Important information on overvoltage The necessity of overvoltage protection on machines and systems as
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationSurge protection for gutter heating systems
Surge protection for gutter heating systems White Paper Contents Structure without external lightning protection system Structure with external lightning protection system www.dehn-international.com Surge
More informationSurge protection for LED mast lights
Surge protection for LED mast lights White Paper Contents Surge arrester installed in the terminal compartment / distributor of the metal mast Surge arrester installed next to the LED mast light with the
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationLightning and surge protection for electromobility
Lightning and surge protection for electromobility White Paper Contents Danger during thunderstorms Damage caused during charging What happens if lightning strikes when charging? What do the standards
More information8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA
8 PHOEIX COTACT Surge protection for the power supply unit Building and industrial installations in different parts of the world have different requirements for lightning and surge protection in the power
More informationApplication-optimised DEHNshield Combined Arrester
with remote signal- NEW ling contact (FM) Application-optimised Combined Arrester www.dehn-international.com 2 protects residential buildings and special applications Ideally suited for residential buildings
More informationRemote contact signaling available. visual status indication
Effective January 2016 Supersedes August 2013 BUSSMANN SERIES PV PRO three module photovoltaic surge protective devices for 600 and 1000Vdc systems Remote contact signaling available easyid local visual
More informationCONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection
CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE
More informationVAL-CP-1S-175. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with
More informationExtract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards
Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs
More informationLeutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14
Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland
More informationOvervoltage Protection Devices
Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge
More informationLightning and Surge Arresters
/ Lightning and Surge Arresters Product overview /3 Introduction /6 Lightning arresters, requirement category I (B) /8 Combination arresters, requirement category I (B) and II (C) /0 Single-pole surge
More informationOvervoltage Protection Devices
Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type
More informationPage 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P
Page -4 Page -4 SURGE PROTECTIO DEVICES TY 1 AD 2 MOOBOCK VERSIOS 1P, 1P+, 2P, 3P, 3P+, 4P IEC impulse current Iimp (10/350μs): 25kA IEC maximum discharge current Imax (8/20μs): 100kA SPD status indicator
More informationOvervoltage Protection Devices
Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type
More informationTT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage
More informationVAL-CP-3S-350. Extract from the online catalog. Order No.:
Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page
More informationSurge Protection Devices and Surge Protection Kit
Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down
More informationOvervoltage Protection Devices
Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type
More informationOvervoltage Protective Devices
Scan this tag to get product information about the New Bussmann Surge Protection products for UL, PV, IEC, Wind Power and Telecom applications. RED indicates NEW information Overvoltage Protective Devices
More informationPT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2-PE/S- 24AC-ST Order No.: 2839318 The illustration shows version PT 2-PE/S-230 AC-ST Protective plug PT with surge voltage equipment protection for power supply units,
More informationTRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs
More informationSPD Catalogue. SPD Catalogue. for AC applications
SPD Catalogue SPD Catalogue for AC applications Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make
More informationLightning and surge protection for intelligent transformer substations
Lightning and surge protection for intelligent transformer substations White Paper Contents Risk analysis and standards Lightning protection zone concept External and internal lightning protection measures
More informationPT 3-PB-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode
More informationSurge Protective Device
Surge Protective Device LED Light / Machine protection SPD Class 2 LT-C34G801W General Information LT-C and LT-HC series Surge Protective Devices are for protection of indirect lightning. They are designed
More informationType 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016
Type 1 Arresters Use in installations with short-circuit currents up to 100 ka rms Definition of follow current, follow current extinguishing capability and short-circuit withstand capability Follow current
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters
Lightning current and surge arresters Application-specific SPD designs SPD for use in satellite and cable TV systems with measuring output Combined lightning current and surge arrester for high discharge
More informationETITEC - Lightning and Surge Arresters
ETITEC Lightning and Surge Arresters Overvoltage protection selection ETITEC selection Define system data: U max Uc > 1,2 x U max External lightning protection exist? NO Apply ETITEC C on string and on
More informationPT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2X2-HF-24 DC-ST Order No.: 2839729 The illustration shows the version PT 2x2-HF-12 DC-ST Protective plug PT with HF protective circuit for two 2-core floating signal
More informationLightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany
Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationPRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION
INTERNAL PROTECTION systems PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION INDUSTRIAL INSTALLATIONS 2 1 2 5 5 7 2 2 2 2 4 6 6 7 3 OBJECT: Industrial premises, Industrial complexes, Hospitals, Public buildings
More informationASI QUINT /2.4 EFD
Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678
More informationLightning & Surge Protection for Wind Turbine Systems
Lightning & Surge Protection for Wind Turbine Systems Product Selection Guide Table of Contents Technologies for Wind Turbine Protection 3 Protective Device Recommendations 4 Class I Strikesorb Surge Protection
More informationPT 2X2-24DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal
More informationInstallation / Control Technique
Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or
More informationSurge Protection Devices Type 1+2
Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement
More informationSurge Protection for Low Voltage Power Systems
Surge Protection for Low Voltage Power Systems 2017 CATALOG Table of Contents About Raycap 3 Introduction 5 Regulatory Standards 6 Surge Protective Device Components & Terminology 8 Low Voltage Power Distribution
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationTT-2-PE- 24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-2-PE- 24DC Order No.: 2838186 Modular terminal block with three-stage surge protection for a floating double conductor, separate ground connection, nominal voltage: 24
More informationBLITZDUCTOR XTU Universal lightning current / surge arrester
Pluggable DIN Rail Mounted SPDs Combined lightning current and surge arrester Max. discharge capacity for balanced data interfaces Capable of carrying lightning currents up to 10 ka (10/50 μs) For installation
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationINFORMATION TECHNOLOGY SYSTEMS
Surge protection for INFORMATION TECHNOLOGY SYSTEMS SPDs for installations and equipment 131 Cross-reference Discontinued Products Alternatives Part No. Type Part No. Type Pluggable SPDs for DIN rail mounting
More informationPT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:
Extract from the online catalog PT 5-HF- 5 DC-ST Order No.: 2838762 The illustration shows variant PT 5-HF-12 DC-ST Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 5
More informationSPM Series Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationSurge & Filter Protection Addressing your industrial power quality needs.
Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin
More informationLightning and surge protection for single-family houses
Lightning and surge protection for single-family houses White Paper Contents Benefits of protecting an antenna by means of an isolated LPS instead of earthing the antenna Protection of the heat pump /
More informationTT-2-PE-M-24DC. Extract from the online catalog. Order No.:
Extract from the online catalog TT-2-PE-M-24DC Order No.: 2920641 Modular terminal block with two-stage surge protection for one operated floating double conductor, disconnect knife on both signal paths,
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationSPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters
The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by
More informationSingle-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring
More informationSingle Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th
V20 -S U oc 20kV ¾ SPD with high energy MOV technology ¾ Max discharge current up to 20kA 8/20μs and open circuit voltage U oc to 20kV. ¾ Pluggable module for easy replacement ¾ Reliable thermal disconnector
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationSwitching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet
1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green
More informationinterface Overvoltage Protection
Overvoltage Protection 569 Contents Contents Low-voltage supply Page Low-voltage supply Selection by function for low-voltage supply The zone concept for lightning protection Applications 572 574 576 Combined
More informationDEHNsignal Remote Signalling and Reception Module POWER SUPPLY SYSTEMS ACCESSORY FOR TYPE 1 ARRESTER
Remote Signalling and Reception Module EN 600-; EN 600-/A; Function indicator of the connected surge protective device Indicates phase failures Floating changeover contact Integrated for EMC-proof signal
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationDEHNsecure protects Direct Current Applications.
DEHNsecure protects Direct Current Applications www.dehn.de 2 Increased safety in direct current systems DEHNsecure protects direct current applications The use of direct current (d.c.) systems has considerably
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationSurge protection for telecommunication connections
Surge protection for telecommunication connections White Paper Contents Lightning and surge protection for an analogue connection with ADSL Lightning and surge protection for an ISDN connection with ADSL
More informationPRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters
Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time
More informationBuilding Surge Protection Information Pack
Building Surge Protection Information Pack For All Your Surge Solutions PD Devices Ltd. Old Station Yard, South Brent, Devon, UK, TQ10 9AL W: www.pddevices.co.uk T: +44 (0)1364 649248 E: sales@pddevices.co.uk
More informationOvervoltage Protection for low-voltage supplies
Class I Overvoltage Protection.2 -.3 with sparkover gaps.4 -.9 with high-power varistors.10 -.11 Overvoltage Protection, combination arrester.12 -.15 Class II Overvoltage Protection with varistors.16 -.25
More informationAutoprotected Surge Arresters New OVR Plus range
Autoprotected Surge Arresters New OVR Plus range A complete solution with the OVR PLUS range Thanks to its continuous innovation on surge protection, ABB improves constantly its offer by launching on the
More informationRE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output
Characteristics off-delay timing relay - control - 1 s..100 h - 24..240 V - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type
More information02/11/2015
DIN Rail Mount 22.5 mm TU2R1 Part number 88865305 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationMINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:
Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial
More informationRE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Width pitch dimension Control type Voltage range Connections - terminals Housing material Main Range
More informationPower Supply HARTING pcon
HARTING pcon 2060 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More informationTechnical features OVR Surge Protective Devices Type 1 & Type 1+2
Type 1 & Type 1+2 TECHNICAL FEATURES Technology Type 1 OVR T1 2 TS Triggered spark-gap Electrical features Standard IEC 61643-1 / EN 61643-11 Type / test class 1 / I Poles 1P - 1P -, 2P 2L 3P 3L 4P 4L
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationSPM Series. Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More information02/11/2015
35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More information08/07/2015
DIN Rail Mount 22.5 mm TUR1 Part number 88865105 Product with 1 relays (88 865 100/103/105/115/125/135/145/155/185/503) : Replaced by the 17,5 mm range For instance : previous part number 88 865 XXX /
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/DC - solid state output Complementary Control type Voltage range Main Range of product Product or component type Discrete output type Width
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationPV protective solutions
PV SPD catalogue PV protective solutions for solar PV applications Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability
More informationLightning Current Equipotential Bonding SPDs
Lightning Current Equipotential Bonding SPDs Introduction Furse is a world leader in the design, manufacture, and supply of earthing and lightning protection systems. Over 100 years of experience makes
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationINFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester
SPD X 2 No. 929 02 Line 7, V 2, ka Surge arrester Surface-mountable surge protective device for telecommunication systems Quick installation due to plug-in terminals Different types specified for interfaces
More informationPower Supply HARTING pcon
HARTING pcon 2120 Advantages Compact design and high power density Easy installation and tool-less connection Wide input range for world-wide use Wide operating temperature range (up to 70 C without derating)
More informationElectronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data
More informationSolid-State Contactors
Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationDeploying surge protective devices (SPDs) in photovoltaic systems. Technical Information
Deploying surge protective devices (SPDs) in photovoltaic systems Technical Information 2 00/09.08 Preface Preface Damages caused by overvoltage s are not only responsible for expensive repair costs; they
More information