PV protective solutions

Size: px
Start display at page:

Download "PV protective solutions"

Transcription

1 PV SPD catalogue PV protective solutions for solar PV applications

2 Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places we live and work safer and more comfortable Hydraulic and electrical solutions that enable machines to deliver more productivity without wasting power Aerospace solutions that make aircraft lighter, safer and less costly to operate, and help airports operate more efficiently Vehicle drivetrain and powertrain solutions that deliver more power to cars, trucks and buses, while reducing fuel consumption and emissions Discover today s Eaton. Powering business worldwide As a global power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses. Eaton s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently, safely and sustainably. We provide integrated solutions that help make energy, in all its forms, more practical and accessible. With 2013 sales of $22 billion, Eaton has approximately 100,000 employees around the world and sells products in more than 175 countries. Eaton.com 2 EATON PV SPD catalogue

3 The need for PV protection Photovoltaic installations are key sources of renewable energy across the world and are increasing both in terms of size and number. The installations have a number of challenges which arise from their exposed nature and vast collection areas. The unique nature of the PV installations makes them vulnerable to overvoltage surges from lightning strikes and static discharges. The core challenge is protecting these installations against direct and indirect lightning strikes which present a high risk of causing damage. The effects of direct or indirect lightning strikes making it into the electrical system can be catastrophic. If significant damage is caused to the installation then the operator is faced with high repair costs to the equipment and a loss of revenue as a result of the loss of output. As a result of this it is essential that the surges are intercepted before they take down the entire system by damaging the PV arrays, charge controller / inverter and combiner boxes. Bussmann is able to mitigate against these threats by providing a comprehensive protective solution to the customer. A range of certified PV DC surge protective devices is available to safeguard the electrical system of the PV installation, preventing damage. In addition to the surge protection devices, Bussmann has a large product portfolio covering the complete PV protective solution; including AC surge protection, PV fuses and a Combiner Box solutions. EATON PV SPD catalogue 3

4 PV system overview To ensure full system protection against the propagation of over voltage surges throughout the PV installation it is important to select the correct Surge Protection Device (SPD) for each part of the system in the DC, AC and data-line networks. The network diagram and table helps to identify the key areas of SPD protection. 4 EATON PV SPD catalogue

5 Look-up table LV Protection Inverter Protection Array Protection Product Line DC PV T1/PV T2 - High Performance DC PV T2 DC PV T2 - High Performance Data line AC T1/2 and T2 String Protection These combined PV T1/ PV T2 devices are certified to provide protection for 600VDCor 1000VDC systems and up to 1000ADC Iscpv. 333 The PV T2 devices are specifically designed for use within 600V or 1000VDC systems with an Iscpv up to 160ADC. 3 High Performance PV T2 designed for high PV currents up to 1000ADC Iscpv with operating voltages of 600VDC or 1000VDC. 333 The Data line range of surge protection devices are specifically designed for communication systems typically found in PV systems, with 4-wire, BNC and RJ45 options The AC range of devices are suitable for T1&T2 or T2 protection of the LV distribution panels and auxiliary equipment with voltages from 75VAD to 580VAC EATON PV SPD catalogue 5

6 PV T1 / PV T2 DC SPD Description This range of modular SPDs are suitable for use within 600Vdc or 1000Vdc systems and provide combined PV T1/PV T2 protection. The heavy duty metal oxide varistors provide higher energy dissipation necessary for combined lightning and surge protection. The IP20 finger safe construction has an operating temperature range from 40 C to +80 C, increasing the operational capability and geographical scope which the SPD devices can be installed in. Tested to 1000A I scpv these combined PV T1/PV T2 SPDs are suitable for use at all levels of the DC element of the photovoltaic system. Standard Features Modular design. Keyed plugs and base elements protect against mismatching. Local and remote monitoring. DIN rail mountable. I scpv = 1000A. 6 EATON PV SPD catalogue

7 Part number SPPVT PE SPPVT PE Part number (with remote indicator) SPPVT PE-AX SPPVT PE-AX Nominal PV System voltage 600 VDC 1000 VDC Max. continuous operating voltage U CPV 720 VDC 1050 VDC Open circuit voltage under standard test conditions U OC STC 600 VDC 875 VDC Short circuit current rating I SCPV 1000A 1000 A SPD Overload behaviour mode OCM (open circuit mode) OCM (Open Circuit Mode) Class of test according to EN PV T1/ PV T2 PV T1 / PV T2 Nominal discharge current I n (8/20)μs: 15 ka 15 ka Max. discharge current I max (8/20)μs: 40 ka 40 ka Total discharge current I total (8/20) μs: 40 ka 40 ka Total discharge current I total (10/350) μs 7 ka 5 ka Impulse discharge current I imp (10/350) μs 5 ka 5 ka Voltage protection level U p (L+/L-) - PE 2.6 kv 3.5 kv Limiting voltage U res (8/20) (L+/L-) - PE at I n 2.6 kv 3.5 kv at 5 ka 2.0 kv 2.9 kv at 10 ka 2.3 kv 3.2 kv at 20 ka 2.8 kv 3.7 kv at 30 ka 3.1 kv 4.1 kv at 40 ka 3.6 kv 4.6 kv Response time t A 25 ns 25 ns Max. required series fuse Not required Not required Continuous operating current I CPV < 20 μa < 20 μa Rated load current I L 80 A 80 A Residual current I PE < 20 μa DC / 350 μa AC < 20 μa DC / 300 μa AC Standby power consumption P C < 20 mva < 25 mva Temperature range -40 C to +80 C -40 C to +80 C Humidity range 5% 95% 5% 95% Altitude 3000 m 3000 m Degree of protection according to IEC :2011 IP20 IP20 Air clearances and creepage distances according to EN Degree of pollution 2 2 Overvoltage category III III Insulating material Housing plug/base element PA 6.6 / PBT PA 6.6 / PBT Inflammability class according to UL 94 V0 V0 CTI According to IEC 112 > 600 > 600 Connection Terminal blocks / Rail mountable NS 35 Terminal blocks / Rail mountable NS 35 Fine-/solid strand/ AWG mm²/ mm²/ mm²/ mm²/ 15-2 Terminal blocks mm² with spade lug terminal M mm² with spade lug terminal M6 Thread / torque / strip length M5/ 4.5 Nm/ 16 mm M5/ 4.5 Nm/ 16 mm Remote indicator contact (..AX parts only) Switching function Single pole changeover contact Single pole changeover contact Connection method Pluggable MC 1.5/3 ST Pluggable MC 1.5/3 ST Wire fine/solid strand/awg mm 2 / AWG (CSA) (UL) mm 2 / AWG (CSA) (UL) Thread / torque / strip length M2 / 0.25 Nm / 7 mm M2 / 0.25 Nm / 7 mm Max admissible operating voltage 250 VAC / 30 VDC 250 VAC / 30 VDC Max admissible power AC 1.5 A / 250 VAC 1.5 A / 250 VAC Max admissible power DC 1.5 A / 30 VDC 1.5 A / 30 VDC Min admissible power 5 ma / 5 V 5 ma / 5 V Certified according to EN EN EATON PV SPD catalogue 7

8 PV T2 standard / high performance Description Designed specifically for PV solar applications, this range of modular PV SPDs are suitable for use within 600Vdc or 1000Vdc systems. They provide fast and reliable protection against indirect lightning strikes and voltage surges. The SPDs contain integrated indication of device status with the option for remote indication helping system operators ensure continuous protection. The IP20 finger-safe construction has an operating temperature range from -40 C to +80 C, increasing the operational capability required for PV environments. Certified to EN these devices provide effective PV Type 2 protection of the DC element of the photovoltaic system from indirect lightning strikes and surges. Features for the T2 Standard SPD I SCPV = 160A Modular design. Keyed plugs and base elements protect against mismatching. Local and remote monitoring. DIN rail mountable. Features for the T2 High Performance SPD I SCPV = 1000A Modular design. Keyed plugs and base elements protect against mismatching. Local and remote monitoring. DIN rail mountable. 8 EATON PV SPD catalogue

9 PV T2 high performance Part number SPPVT2H-06-2-PE SPPVT2H-10-2-PE Part number (with remote indication) SPPVT2H-06-2-PE-AX SPPVT2H-10-2-PE-AX Nominal PV System voltage 600 VDC 1000 VDC Max. continuous operating voltage U CPV 800 VDC 1170 V DC Open circuit voltage under standard test conditions U OC STC 670 VDC 970 V DC Short circuit current rating I SCPV 1000 A 1000 A SPD Overload behaviour mode OCM (Open Circuit Mode) OCM (Open Circuit Mode) Class of test according to EN PV T2 PV T2 Nominal discharge current I n (8/20)μs: 15 ka 15 ka Max. discharge current I max (8/20)μs: 40 ka 40 ka Total discharge current I total (8/20) μs: 40 ka 40 ka Voltage protection level U p (L+ / L-) - PE 2.7 kv 3.7 kv Limiting voltage U res (8/20) (L+ / L-) - PE at 1 A 2.7 kv 3.7 kv at 2 ka 1.9 kv 2.7 kv at 5 ka 2.2 kv 3.1 kv at 10 ka 2.5 kv 3.5 kv at 20 ka 2.9 kv 4.0 kv at 30 ka 3.4 kv 4.6 kv at 40 ka 3.8 kv 5.0 kv Response time t A 25 ns 25 ns Max. required series fuse Not required Not required Continuous operating current I CPV < 20 μa < 20 μa Rated load current I L 80 A 80 A Residual current I PE < 20 μa DC / 300 μa AC < 20 μa DC / 250 μa AC Standby power consumption P C < 20 mva < 25 mva Temperature range -40 C to +80 C -40 C to +80 C Humidity range 5% 95% 5% 95% rel Altitude 3000 m 3000 m Degree of protection according to IEC :2011 IP20 IP20 Air clearances and creepage distances according to EN degree of pollution 2 2 overvoltage category III III Insulating material housing plug/base element PA 6.6 / PBT PA 6.6/ PBT inflammability class according to UL 94 V0 V0 CTI According to IEC 112 > 600 > 600 Connection Terminal blocks / Rail mountable NS 35 Terminal blocks / Rail mountable NS 35 Fine-/solid strand/ AWG mm²/ mm²/ ' to 25 mm²/ 1.5 to 35 mm²/ 15-2 Terminal blocks mm² with spade lug terminal M6 1.5 to 16mm² with spade lug terminal M6 Thread/torque/strip length M5/ 4.5 Nm/ 16 mm M5/ 4.5 Nm/ 16mm Remote indicator contact (..AX parts only) Switching function Single pole changeover contact Single pole changeover contact Connection method Pluggable MC 1.5/3 ST Pluggable MC 1.5/3 ST Wire fine/solid strand/awg mm 2 / AWG (CSA) (UL) mm 2 / AWG (CSA) (UL) Thread / torque / strip length M2 / 0.25 Nm / 7 mm M2 / 0.25 Nm / 7 mm Max admissible operating voltage 250 VAC / 30 VDC 250 VAC / 30 VDC Max admissible power AC 1.5 A / 250 VAC 1.5 A / 250 VAC Max admissible power DC 1.5 A / 30 VDC 1.5 A / 30 VDC Min admissible power 5 ma / 5 V 5 ma / 5 V Certified according to EN EN EATON PV SPD catalogue 9

10 PV T2 standard Part number SPPVT PE SPPVT PE Part number (with remote indication) SPPVT PE-AX SPPVT PE-AX Nominal PV System voltage 600 VDC 1000 VDC Max. continuous operating voltage U CPV 800 VDC 1170 V DC Open circuit voltage under standard test conditions U OC STC 670 VDC 970 V DC Short circuit current rating I SCPV 160 A 160 A SPD Overload behaviour mode OCM (Open Circuit Mode) OCM (Open Circuit Mode) Class of test according to EN PV T2 PV T2 Nominal discharge current I n (8/20)μs: 15 ka 15 ka Max. discharge current I max (8/20)μs: 40 ka 40 ka Total discharge current I total (8/20) μs: 40 ka 40 ka Voltage protection level U p (L+ / L-) - PE 2.7 kv 3.7 kv Limiting voltage U res (8/20) (L+ / L-) - PE at 1 A 2.7 kv 3.7 kv at 2 ka 1.9 kv 2.7 kv at 5 ka 2.2 kv 3.1 kv at 10 ka 2.5 kv 3.5 kv at 20 ka 2.9 kv 4.0 kv at 30 ka 3.4 kv 4.6 kv at 40 ka 3.8 kv 5.0 kv Response time t A 25 ns 25 ns Max. required series fuse Not required Not required Continuous operating current I CPV < 20 μa < 20 μa Rated load current I L 80 A 80 A Residual current I PE < 20 μa DC / 300 μa AC < 20 μa DC / 250 μa AC Standby power consumption P C < 20 mva < 25 mva Temperature range -40 C to +80 C -40 C to +80 C Humidity range 5% 95% 5% 95% rel Altitude 3000 m 3000 m Degree of protection according to IEC :2011 IP20 IP20 Air clearances and creepage distances according to EN degree of pollution 2 2 overvoltage category III III Insulating material housing plug/base element PA 6.6 / PBT PA 6.6/ PBT inflammability class according to UL 94 V0 V0 CTI According to IEC 112 > 600 > 600 Connection Terminal blocks / Rail mountable NS 35 Terminal blocks / Rail mountable NS 35 Fine-/solid strand/ AWG mm²/ mm²/ ' to 25 mm²/ 1.5 to 35 mm²/ 15-2 Terminal blocks mm² with spade lug terminal M6 1.5 to 16mm² with spade lug terminal M6 Thread/torque/strip length M5/ 4.5 Nm/ 16 mm M5/ 4.5 Nm/ 16mm Remote indicator contact (..AX parts only) Switching function Single pole changeover contact Single pole changeover contact Connection method Pluggable MC 1.5/3 ST Pluggable MC 1.5/3 ST Wire fine/solid strand/awg mm 2 / AWG (CSA) (UL) mm 2 / AWG (CSA) (UL) Thread / torque / strip length M2 / 0.25 Nm / 7 mm M2 / 0.25 Nm / 7 mm Max admissible operating voltage 250 VAC / 30 VDC 250 VAC / 30 VDC Max admissible power AC 1.5 A / 250 VAC 1.5 A / 250 VAC Max admissible power DC 1.5 A / 30 VDC 1.5 A / 30 VDC Min admissible power 5 ma / 5 V 5 ma / 5 V Certified according to EN EN EATON PV SPD catalogue

11 Plug-in modules When the SPD reaches the end of its life and indicates that it needs to be replaced Bussmann is able to provide replacement modules for the full range of DC PV SPDs. Each plug-in module is key coded and specific for the frame which they clip into. This allows the operator to be certain that the correct module is in place and providing the level of protection which is required. The modular design makes the replacement of parts quick and efficient. The frame remains wired into the system whilst the modules are replaced. Standard Features Keyed plugs, prevent against mismatching. Easy clip in/ clip out. Local monitoring built in. Part number on the front, allows for easy re-ordering. Thermoplastic enclosure Part number SPPVT12-06 SPPVT12-10 SPPVT2H-10 SPPVT2H-06 SPPVT2-10 SPPVT2-06 Nominal PV System Voltage 600 VDC 1000 VDC 1000 VDC 600 VDC 1000 VDC 600 VDC Max. continuous operating voltage U CPV 360 VDC 525 VDC 585 VDC 400 VDC 585 VDC 400 VDC Open circuit voltage under standard test conditions U OC STC 300 VDC 435 VDC 485 VDC 330 VDC 485 VDC 330 VDC Short circuit current rating I SCPV 1000A 1000A 1000A 1000A 160A 160A SPD overload behaviour mode OCM (open circuit mode) OCM (open circuit mode) OCM (open circuit mode) OCM (open circuit mode) OCM (open circuit mode) OCM (open circuit mode) Class of test according to EN PV T1/ PV T2 PV T1/ PV T2 PV T2 PV T2 PV T2 PV T2 Nominal discharge current I n (8/20)μs 15 ka 15 ka 15 ka 15 ka 15 ka 15 ka Max. discharge current I max (8/20) μs 40 ka 40 ka 40 ka 40 ka 40 ka 40 ka Voltage protection level U P (L+/L-) - PE 5 ka 5 ka 1.9 kv 1.4 kv 1.9 kv 1.4 kv Limiting voltage (8/20) (L+/L-) - PE at I n 1.4 kv 1.8 kv 1.9 kv 1.4 kv 1.9 kv 1.4 kv At 2 ka 1.0 kv 1.4 kv 1.4 kv 1.0 kv 1.4 kv 1.0 kv At 5 ka 1.1 kv 1.5 kv 1.5 kv 1.1 kv 1.5 kv 1.1 kv At 10 ka 1.2 kv 1.7 kv 1.7 kv 1.3 kv 1.7 kv 1.3 kv At 20 ka 1.5 kv 1.9 kv 2.0 kv 1.5 kv 2.0 kv 1.5 kv At 30 ka 1.6 kv 2.2 kv 2.3 kv 1.8 kv 2.3 kv 1.8 kv At 40 ka 1.8 kv 2.4 kv 2.5 kv 2.0 kv 2.5 kv 2.0 kv Response time t A 25 ns 25 ns 25 ns 25 ns 25 ns 25 ns Max. required series fuse Not required Not required Not required Not required Not required Not required Continuous operating current I CPV < 20 μa < 20 μa < 20 μa < 20 μa < 20 μa < 20 μa Residual current I PE Standby power consumption P C < 10 mva < 15 mva < 15 mva < 10 mva < 15 mva < 10 mva Temperature range -40 C to +80 C -40 C to +80 C -40 C to +80 C -40 C to +80 C -40 C to +80 C -40 C to +80 C Humidity range 5% 95% 5% 95% 5% 95% 5% 95% 5% 95% 5% 95% Altitude 3000 m 3000 m 3000 m 3000 m 3000 m 3000 m Degree of protection according to IEC : 2011 IP20 IP20 IP20 IP20 IP20 IP20 Contamination level Surge voltage category III III III III III III Housing plug/ base element PA 6.6 / PBT PA 6.6 / PBT PA 6.6 / PBT PA 6.6 / PBT PA 6.6 / PBT PA 6.6 / PBT Inflammability class according to UL 94 V0 V0 V0 V0 V0 V0 CTI according to IEC 112 > 600 > 600 > 600 > 600 > 600 > 600 Certified according to EN EN EN EN EN EN EATON PV SPD catalogue 11

12 AC SPDs Overview Bussmann can provide a range of AC surge protection devices suitable to provide Type 1, Type 1&2 and Type 2 protection for the AC side of the PV system for auxiliary equipment and AC LV distribution panels. The AC SPDs provide quick and efficient protection against the effects of overvoltages within AC power systems. Manufactured from thermoplastic, these SPDs are available from 75 to 580VAC and provide protection for within powered monitored combiner boxes, the inverter, and computer equipment used for monitoring and control. Standard Features Modular design. DIN rail mountable. Local and remote monitoring. Keyed plugs and base elements protect against mismatching. System voltage VAC Number of poles 1, 1+NPE, 2, 3, 3+NPE, 4 Modular design Yes, replacement modules available Degrees of protection Type 1, Type 1&2, Type 2 Operating temperature range* -40 C to +70 C Remote monitoring available Yes IP rating IP40 Product warranty 2 years Enclosure material Thermoplastic UL 94 V2 Location category Indoor Mounting Quick fastening on DIN rail according to IEC/ EN Cross sectional area (min.)* 4mm² Cross sectional area (max.)* 25mm² * Model dependent 12 EATON PV SPD catalogue

13 Data-line SPDs Today many medium and large size PV systems incorporate a variety of communication systems to monitor system performance or provide security and surveillance. These communication systems also need to be adequately protected from potentially damaging overvoltage surges. The Bussmann range of data-line SPDs are specifically designed to provide surge protection for 2-wire and 4-wire RS-485 interfaces, RJ45 communications and BNC for video configurations. Importantly, installing this range of SPDs within the system will protect not only the electrical interface but also the wider network and the equipment associated with it. Twisted pair data cables Connectors Screw Voltage 5V, 12V, 24V, 48V, 0-180V D1 Total lightning impulse current (10/350μs) I imp 10kA C2 total nominal discharge current (8/20μs) I n 20kA Grounding DIN-Rail Applications Measurement, control and regulation, twisted pairs Test standards IEC / EN , UL 447B RJ45 / Ethernet Connectors Voltage C2 Nominal discharge current (8/20μs) line-pg I n Grounding Applications Test standards RJ45 48V 2.5kA DIN-Rail RJ45 Connector ethernet cables IEC / EN , UL 447B BNC Coaxial cable Connectors Voltage Nominal discharge current (8/20μs) line-pg I n Grounding Applications Test standards BNC 5V 10kA DIN-Rail BNC Connector coaxial cables and video IEC / EN , UL 447B EATON PV SPD catalogue 13

14 Photovoltaic fuse links and fuse holders Available in a range of sizes and in 1000 & 1500Vdc, Bussmann s range of fuses are specifically designed to provide high quality protection and isolation for photovoltaic array combiners, recombiners and inverters. These fuse links are capable of interrupting low overcurrents associated with faulted PV systems. Photovoltaic fuse links and fuse holders Standard IEC , , and , UL Listed and CCC Accredited Voltage 1000 to 1500 VDC Current 1 to 630 A Breaking capacity Up to 50 ka Operating class gpv Sizes 10 x 38, 14 x 51, 14 x 65, NH Style and XL Style Fuse holders CHPV series for 10 x 38 fuse links, SD-D-PV for NH Style, SD-XL-S for XL Style Applications PV panel, string, array protection Combiner box Bussmann by Eaton manufactures completely customisable combiner boxes from 3 to 24 strings, offering a unique product which is developed specifically for individual installations. Configurable to provide overcurrent fuse protection, overvoltage surge protection, DC switch isolation and full system monitoring with a choice of power supply options. Specifically designed for the harsh environmental conditions of PV installations the Bussmann by Eaton combiner box provides safe reliable system protection in ambient temperatures up to 50 C. With a global manufacturing base, Bussmann can design and manufacture customised combiner boxes within competitive timeframes whilst maintaining exceptional levels of quality to your requirement. Combiner box Standard IEC and -2 and IEC Voltage Up to 1000 VDC Current 1 to 32 A Number of strings 3-24 strings (20 A fuse max), 3-16 strings (32 A fuse max) Operating class gpv IP Rating IP65 (options for IP55) Enclosure types Glass reinforced polyester (GRP), painted steel, stainless steel Overcurrent protection confi gurations Positive and negative, positive only, negative only DC Load isolation DC switch disconnect 25 Adc to 500 Adc or fi xed output Input connection types Bottom or side entry MC4 connectors or glands Overvoltage protection options (SPD) PV T1/T2, PVT2, AC T1, T1/T2 & T2. Dataline D1, C2 Monitoring options 8/16/24 string shunt based monitoring. Communications options 2-Wire modbus Power supply options External 24 VDC, Internal 240 VAC to 24 VDC, Internal 1000 VDC to 24 VDC Applications Solar PV applications including: Large scale residential, small to large scale commercial, large scale utility 14 EATON PV SPD catalogue

15 Frequently asked questions (FAQs) How does an SPD work? A surge protector works by momentarily switching from an open circuit mode into a low impedance mode and shunting the surge energy to the ground, limiting the overvoltage to a safe level in the process. When the surge event is over the protector returns to its open circuit mode, ready for the next event. Why does a PV installation require an SPD? Due to the PV installation s exposed nature and large collection area, it is increasingly prone to direct and indirect lightning strikes or transient overvoltage conditions. An SPD will prevent damage to the installation, preventing high repair costs to components and lost revenue from loss of output. Which SPD is suitable to use? This depends on a variety of factors including the geographical location, the equipment which is being protected and the importance of its operation. The configuration of the Earth and neutral conductors is also critical. Please call Bussmann to discuss your requirements on +44 (0) How long does an SPD last? How long an MOV SPD lasts depends on the frequency and size of the overvoltage event. The greater the transient event, the greater the degradation of the MOV. What is a modular SPD? A modular SPD contains modules which can be replaced without replacing the entire SPD unit, making maintenance easy and minimizing time with reduced protection. The modules allow decreased labour and cost which is required for servicing the protector. How to replace an SPD at the end of life. Eaton is able to offer replacement plug in modules for each of the parts on offer. The modules clip in and clip out without requiring the whole device to be unwired from the system. What is an MOV? A Metal Oxide Varistor is a variable resistor typically made up of a large block of zinc oxide grains. They act like semi-conductors, an insulator below the conduction voltage and a low value resistor above it. In conduction mode, the MOV diverts and dissipates the overvoltage transient to Earth. MOVs generally connect from the line conductors to Earth. The thickness of the MOV determines the clamping voltage and diameter determines the current capacity. EATON PV SPD catalogue 15

16 Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers most critical challenges. Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit Contact your local Eaton Office Cooper Bussmann (UK) Ltd Melton Road Burton-on-the-Wolds LE12 5TH United Kingdom Tel: +44 (0) Eaton Industries Manufacturing GmbH Electrical Sector EMEA Route de la Longeraie Morges, Switzerland Eaton.eu 2014 Eaton All Rights Reserved Printed in the United Kingdom Publication No. BR132002EN July 2014 Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. Eaton is a registered trademark. All other trademarks are property of their respective owners.

SPD Catalogue. SPD Catalogue. for AC applications

SPD Catalogue. SPD Catalogue. for AC applications SPD Catalogue SPD Catalogue for AC applications Eaton and Cooper united. Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

Remote contact signaling available. visual status indication

Remote contact signaling available. visual status indication Effective January 2016 Supersedes August 2013 BUSSMANN SERIES PV PRO three module photovoltaic surge protective devices for 600 and 1000Vdc systems Remote contact signaling available easyid local visual

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

ETITEC - Lightning and Surge Arresters

ETITEC - Lightning and Surge Arresters ETITEC Lightning and Surge Arresters Overvoltage protection selection ETITEC selection Define system data: U max Uc > 1,2 x U max External lightning protection exist? NO Apply ETITEC C on string and on

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type

More information

VAL-CP-1S-175. Extract from the online catalog. Order No.:

VAL-CP-1S-175. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-1S-175 Order No.: 2859479 Pluggable type 2 arrester (surge arrester) for 1-phase current supply networks with separate N and PE (3-conductor system: L1, N, PE), with

More information

Cylindrical fuse links gg/gl and am

Cylindrical fuse links gg/gl and am Supersedes April 2017 BUSSMANN SERIES Product description Eaton s Bussmann series Cylindrical fuse links, class gg/gl and am, are suitable for industrial applications. Standard features Compact design

More information

Surge Protection Devices and Surge Protection Kit

Surge Protection Devices and Surge Protection Kit Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down

More information

VAL-CP-3S-350. Extract from the online catalog. Order No.:

VAL-CP-3S-350. Extract from the online catalog. Order No.: Extract from the online catalog VAL-CP-3S-350 Order No.: 2859521 Commercial data EAN 4017918977610 Pack 1 Pcs. Customs tariff 85363030 Weight/Piece 388.83 g Product key J020 Catalog page information Page

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 3-PB-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 3-PB-ST Order No.: 2858030 Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode

More information

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE Surge Protection Device CHOICE OF SURGE PROTECTION DEVICES FOR PHOTOVOLTAIC APPLICATIONS General concept To achieve complete functionality

More information

Reliability in Surge Protection. Photovoltaic Systems.

Reliability in Surge Protection. Photovoltaic Systems. Reliability in Surge Protection Photovoltaic Systems www.citelcp.com Roof top installations For low power PV applications, i.e. residences and small offices, it is necessary to consider surge protecting

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.

More information

R3&A Limited, Cobourg, ON

R3&A Limited, Cobourg, ON R3&A imited, Cobourg, ON ightning and Surge Protection Devices for North America Easy Choice POWER SUPPY SYSTEMS Main distribution board (Category C) Class I ightning current arrester Subdistribution board

More information

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

TT-UK5/ 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-UK5/ 24DC Order No.: 2794699 Modular terminal block with surge voltage fine protection between clamping connector and DIN rail, nominal voltage: 24 V DC, for mounting

More information

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14 Leutron Lightningand Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices Seite 0 von14 Novelties 2003 Combi Surge Protectors Leutron GmbH, 70771 Leinfelden-Echterdingen, Deutschland

More information

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards Extract from the online catalog SFP 1-5/120AC Order No.: 2920667 Device surge protection filter to limit powerful surge voltages, mounting on NS 35. Commercial data EAN 4046356158558 Pack 1 pcs. Customs

More information

Lightning Current Equipotential Bonding SPDs

Lightning Current Equipotential Bonding SPDs Lightning Current Equipotential Bonding SPDs Introduction Furse is a world leader in the design, manufacture, and supply of earthing and lightning protection systems. Over 100 years of experience makes

More information

Power supply CP-C 24/5.0

Power supply CP-C 24/5.0 2CDC 271 064 F0004 Features Supply voltage ranges: 85-264 V AC, 100-350 V DC Output voltage adjustable from 22-28 V DC, default setting 24 V DC 0,5 % 5 A output current Open-circuit, overload and continous

More information

Company Profile Surge Protective Devices

Company Profile Surge Protective Devices Company Profile Surge Protective Devices Who we are What we do SALTEK is a leading Czech based company specialising in the development and production of Surge Protective Devices. SALTEK offers a complete

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-24DC-ST Order No.: 2838228 The illustration shows version PT 2x2-5DC-ST Protective plug PT with protective circuit for two 2-core floating signal circuits. Nominal

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2-PE/S- 24AC-ST Order No.: 2839318 The illustration shows version PT 2-PE/S-230 AC-ST Protective plug PT with surge voltage equipment protection for power supply units,

More information

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Technical features OVR Surge Protective Devices Type 1 & Type 1+2 Type 1 & Type 1+2 TECHNICAL FEATURES Technology Type 1 OVR T1 2 TS Triggered spark-gap Electrical features Standard IEC 61643-1 / EN 61643-11 Type / test class 1 / I Poles 1P - 1P -, 2P 2L 3P 3L 4P 4L

More information

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 2X2-HF-24 DC-ST Order No.: 2839729 The illustration shows the version PT 2x2-HF-12 DC-ST Protective plug PT with HF protective circuit for two 2-core floating signal

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

Surge Protection Devices Type 1+2

Surge Protection Devices Type 1+2 Surge Protection Devices Type 1+2 Description The combined surge protection devices offer as an all-in-one solution lightning and surge-voltage in one device. They are in accordance with the requirement

More information

wietap wietap Overvoltage Protection Tensions running high

wietap wietap Overvoltage Protection Tensions running high wietap wietap Overvoltage Protection Tensions running high 2 wietap wietap Overvoltage protection Important information on overvoltage The necessity of overvoltage protection on machines and systems as

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

Installation / Control Technique

Installation / Control Technique Installation / Control Technique Interface Relay, Interface Relay System Input-Output Interface Relay IK 3070, I_ 3070 0633 IK 3070 Circuit Diagrams IS 3070 According to IEC/EN 61 810-1 Relay, triac or

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

Lightning and Surge Protection for PV Systems

Lightning and Surge Protection for PV Systems Lightning and Surge Protection for PV Systems Application Note (AU) Phillip Tompson Introduction Like all electrical equipment photovoltaic systems can be damaged by both direct and indirect lightning

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

AFDD+- arc fault detection device application guide

AFDD+- arc fault detection device application guide Eaton AFDD + www.eaton.com AFDD+- arc fault detection device application guide The technology behind the AFDD+ (Arc Fault Detection Device) will help you to further reduce the risk of fi re. Conventional

More information

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. SECTION 26 43 00 SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment. 1.2 DEFINITIONS A. ATS:

More information

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

TT-2-PE-M-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE-M-24DC Order No.: 2920641 Modular terminal block with two-stage surge protection for one operated floating double conductor, disconnect knife on both signal paths,

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.: Extract from the online catalog PT 5-HF- 5 DC-ST Order No.: 2838762 The illustration shows variant PT 5-HF-12 DC-ST Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 5

More information

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th V20 -S U oc 20kV ¾ SPD with high energy MOV technology ¾ Max discharge current up to 20kA 8/20μs and open circuit voltage U oc to 20kV. ¾ Pluggable module for easy replacement ¾ Reliable thermal disconnector

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

SPM Series. Plug-in Surge Protection

SPM Series. Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-2-PE- 24DC Order No.: 2838186 Modular terminal block with three-stage surge protection for a floating double conductor, separate ground connection, nominal voltage: 24

More information

Electronic timer CT-ERD.12

Electronic timer CT-ERD.12 2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching

More information

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h. On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

US Catalog March Surge protective devices (SPDs) UL range

US Catalog March Surge protective devices (SPDs) UL range US Catalog March 017 Surge protective devices (SPDs) UL range Surge protective devices (SPDs) UL range Introduction 1 1 OVR surge protective devices Joslyn surge protective devices Marketing tools 4 US

More information

Lightning and Surge Arresters

Lightning and Surge Arresters Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement

More information

2U Congestion Alert Rack Insert for UK

2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Delivery program Contactor relay, 3N/O+1N/C, DC current Part no. DILA-31(24VDC) Catalog No. 276379 Eaton Catalog No. XTRE10B31TD EL-Nummer 4130206 (Norway) Product range DILA relays Application Contactor

More information

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA

SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y RESPALDADOS POR EDCEECA EN VENEZUELA SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4 TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST

More information

BSPD Surge Protective Devices

BSPD Surge Protective Devices BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Datasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations

Datasheet SPD II 1 Surge Protectors for AC Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations Datasheet SPD II 1 Surge Protectors for A Power Distribution SPD II PV Surge Protectors for Photovoltaic Installations Weidmuller s SPD II 1 series transient voltage surge protectors consist of a range

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-SLKK5/ 24DC Order No.: 2794903 The illustration shows version TT-SLKK5/ 12 DC Modular terminal block with varistor as surge voltage protection between clamping connector

More information

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION INTERNAL PROTECTION systems PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION INDUSTRIAL INSTALLATIONS 2 1 2 5 5 7 2 2 2 2 4 6 6 7 3 OBJECT: Industrial premises, Industrial complexes, Hospitals, Public buildings

More information

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

8 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 8 PHOEIX COTACT Surge protection for the power supply unit Building and industrial installations in different parts of the world have different requirements for lightning and surge protection in the power

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

Surge Protection for Low Voltage Power Systems

Surge Protection for Low Voltage Power Systems Surge Protection for Low Voltage Power Systems 2017 CATALOG Table of Contents About Raycap 3 Introduction 5 Regulatory Standards 6 Surge Protective Device Components & Terminology 8 Low Voltage Power Distribution

More information

Surge Protection & Monitoring Solutions for Photovoltaic Systems

Surge Protection & Monitoring Solutions for Photovoltaic Systems Surge Protection & Monitoring Solutions for Photovoltaic Systems Raycap Products Provide the Ultimate Lightning Surge Protection for Photovoltaic Systems The remote locations, exposed surface areas and

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty DIN RAIL MOUNTED ACTIVE TRACKING FILTERS WITH SURGE PROTECTION maximize protection STFE Elite Series Active tracking filter with surge protection Features Series connected DIN Rail mounted filter Patented

More information

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty DIN RAIL MOUNTED ACTIVE TRACKING FILTERS WITH SURGE PROTECTION maximize protection STFE Elite Series Active tracking filter with surge protection Features Series connected DIN Rail mounted filter Patented

More information

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description Primaryswitched power supply unit Data sheet 105549_en_00 PHOENIX CONTACT 20130405 1 Description The UNO POWER power supply unit impresses in worldwide use thanks to maximum energy efficiency. Low noload

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI otor Controllers AC Semiconductor otor Controller Type RSHR IDI Soft starting and stopping of 3-phase induction squirrel cage motors 2-phase control with integral bypassing of semiconductors Low inrush

More information

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35JA32MR Current control relay 0.15A 15A, 2 C/O Characteristics Current control relay 0.15A 15A, 2 C/O Main Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay type Switching capacity in VA Measurement

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

Surge & Filter Protection Addressing your industrial power quality needs.

Surge & Filter Protection Addressing your industrial power quality needs. Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin

More information

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

SAFETY RELAY YRB-4EML-31S MAIN FEATURES SAFETY RELAY TYPE 4 SAFETY PROTECTION DEVICE FOR SAFETY LIGHT CURTAINS/BARRIERS MAIN FEATURES For safety light curtains and access control barriers, emergency stop, door switch Safety Integrity Level (SIL)

More information

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P Page -4 Page -4 SURGE PROTECTIO DEVICES TY 1 AD 2 MOOBOCK VERSIOS 1P, 1P+, 2P, 3P, 3P+, 4P IEC impulse current Iimp (10/350μs): 25kA IEC maximum discharge current Imax (8/20μs): 100kA SPD status indicator

More information

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay

More information

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS G1 Outdoor Surge Protector for AC/Traction network VP range Dimensions (in mm) 19 M8 44 73 diam. 47 6 mm² Electrical

More information

Surge protection for gutter heating systems

Surge protection for gutter heating systems Surge protection for gutter heating systems White Paper Contents Structure without external lightning protection system Structure with external lightning protection system www.dehn-international.com Surge

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

Electronic timer CT-AHD.22

Electronic timer CT-AHD.22 2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016 Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave

More information

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment NTSA has developed the ultimate solution for protecting

More information

DX561 Digital Input/Output Module

DX561 Digital Input/Output Module Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

2 Principle of lightning protection

2 Principle of lightning protection 2 Principle of lightning protection The system for protecting a building against the effects of lightning must include: bprotection of structures against direct lightning strokes; bprotection of electrical

More information

Product Guide. UL 489 DIN rail miniature circuit breakers

Product Guide. UL 489 DIN rail miniature circuit breakers Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at

More information