FR202/-RP. Flashlink 2RU frame. User manual Rev. A. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

Size: px
Start display at page:

Download "FR202/-RP. Flashlink 2RU frame. User manual Rev. A. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion."

Transcription

1 FR202/-RP Flashlink 2RU frame User manual Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.com

2 Nevion Support Nevion Europe P.O. Box Sandefjord, Norway Support phone 1: Support phone 2: Nevion USA 1600 Emerson Avenue Oxnard, CA 93033, USA Toll free North America: (866) Outside North America: +1 (805) See for service hours for customer support globally. Revision history Current revision of this document is the uppermost in the table below. Rev. Repl. Date Sign Change description A MR Initial release nevion.com 2

3 Contents Revision history Product overview Specifications General specifications Front view Rear view Power consumption Configuration Address setting on each frame PSU redundancy mode selection Connections Power connection GPI Power Supply Status outputs RS-422 connection Pin-out RS-422 (RJ45) Connecting several frames together Sync input/output Frame operation Removing the front panel Backplane insertion Main module insertion Card removal PSU insertion PSU removal Attaching the front panel Frame status (LEDs) Multicon Fans Fan operation Replacing defective fans Fiber optics Laser safety precautions Handling of optical fibers Optical connectors Flashlink control protocol Document conventions Hardware interface Addressing General command structure Card detection (hot swap) Hello command Electrical to optical converters Hello command Info command Optical to electrical converters Hello command Info command...30 Product Warranty nevion.com 3

4 Appendix A Materials declaration and recycling information A.1 Materials declaration...33 A.2 Recycling information...33 nevion.com 4

5 1 Product overview The FR202 (-RP) frame, is a compact frame, providing space for up to 20 Flashlink modules, in addition to two fixed positions for power supply modules and one fixed position for a possible future control board. The frame features maximum flexibility as every module comes with a dedicated backplane module, which takes up n x 7TE spacing. The 3.5TE distance between card positions opens for connection of two Flashlink modules to one 7TE backplane. The number of backplanes with 3.5TE module distance (utilizing all 20 positions) is currently limited, but will be expanded in the future. Each frame can be controlled by a Multicon System Controller card, together with up to 7 other frames. The sync function makes it possible to provide a common sync signal to all card positions. Power consumption The current draw in the Flashlink frame is limited by the power supplies. Overloading the power supplies will cause the power units to malfunction. Please read chapter 2.4 for further details! Heat dissipation The heat dissipation is based on convection as well as cooling by fans, and it is therefore very important not to block the warm air exhaust perforations in the chassis. nevion.com 5

6 2 Specifications 2.1 General specifications AC Power: PWR-AC-160W AC power supply module VAC. Redundant Power PWR-AC-160W (optional): Dimensions: 19 width 2RU height Card slots: 20 for Flashlink modules, 1 allocated for a possible future board Power Supply slots 2. Internal voltages: Sync: GPI: +5V, +15V, -15V. Return loss; typical <14dB, 0-5MHz (dependent of the quality of the termination at Power C5) Open drain output from each power supply which turns low ohmic in an alarm situation. To withstand +10VDC (open) and 100mADC (at less than 50mOhm) (closed) 2.2 Front view The front view of the frame shows status LEDs for the power supply modules. Figure 1:Front view of the Flashlink frame. The two LEDs at the front have the following functions: Upper LED: Voltage and current alarm, internal voltages Lower LED: Fan and temperature alarm nevion.com 6

7 2.3 Rear view Figure 2 shows an example of a fully equipped Flashlink frame, seen from the rear side. The outer left and outer right modules are backplanes for the power supplies and contain connections as follows; - Left backplane; o IEC-C14 AC mains inlet o BNC, sync in - Right backplane; o IEC-C14 AC mains inlet o BNC, sync out o 2pcs. RJ-45 for RS-422 in/out o Rotary switch for programming frame number to be read by Multicon o 4 pin connector, GPI out *The other connector modules are described in their respective user manuals. Figure 2: Illustration of fully equipped Flashlink frame. Figure 3: Flashlink frame equipped with blanks. nevion.com 7

8 2.4 Power consumption The current draw in the Flashlink frame is limited by the power supplies. Overloading the power supplies will cause them to malfunction. The power and current limits for the frame, even with two active power supplies, are as follows: Total: 130W (Remaining available 30W up to 160W is dedicated for Fanboard and fans) +5V: 20A +15V: 8.7A -15V: 2A The power consumption can be drawn from the three voltages in any combination, though not exceeding 130W in total. The sum of power for all cards on each rail must not be higher than the above listed limits. The power consumption for each of the power supply rails is found in the user manual for each Flashlink card, as this is not the same for all Flashlink cards. Remark: The power supplies support load sharing giving them extended life time. Though the total potential power supply capacity is actually doubled in a redundant coupling, the above listed maximum power limits for the frame shall never be exceeded. nevion.com 8

9 3 Configuration 3.1 Address setting on each frame Each frame can be assigned an address through the rotary switches on the rear. Maximum 8 frame addresses (0-7) are available, this means that pos. 8 and 9 on the rotary switch are not valid This address setting only applies when the frame is used in combination with a GYDA-SC Rack System Controller. If you have more than 8 frames together, you need several GYDA-SC Rack System Controller cards. In order to ensure proper operation of the system, it is important that no frames controlled by the same GYDA-SC Rack System Controller card have the same address set. Reset the frame after reconfiguring the frame system, by turning the power off and on again. Valid positions: 0-7 Figure 4: Rotary switch More detailed information on the RS-422 configuration can be found in a separate document and at our web site: nevion.com 9

10 3.2 PSU redundancy mode selection The frame comes equipped with a jumper mounted at the programming header at the Fanboard. Depending on the desired mode the jumper shall be mounted as described in the figure below. Figure 5: Location of jumper for redundancy mode selection nevion.com 10

11 4 Connections 4.1 Power connection Figure 3 shows the power connections of the frame as well as the RS-422 connections and the rotary-switch for address setting of the frame. Figure 6: Connector module for the power supply. AC: Connect mains to the frame with a mains cord with an IEC 320 connector. To ensure a safe connection a cable with IEC-lock connector should be used. Such cables can be ordered from Nevion. A green LED will light on the front when the power supply is in operation mode. For a faulty power supply LED will have red light or no light. 4.2 GPI Power Supply Status outputs The GPI module status outputs can be used for wiring up alarms for third party control systems. GND Not connected GPI from nearest power supply GPI from farthest power supply Figure 7: GPI connector In an alarm situation the GPI output is connected low ohmic to GND. nevion.com 11

12 4.3 RS-422 connection At the rear end of the frame is an RS-422 bus. When used in combination with the Multicon Rack System Controller, up to 8 frames can be controlled. On the rear end of the frame is a rotary switch by witch each frame can be assigned its own address (see figure 3). The RS-422 interface is shown in figure Pin-out RS-422 (RJ45) Pin #1 Rx A (+) Pin #2 Rx B (-) Pin #3 Tx A (+) Pin #4 Reserved Pin #5 Reserved Pin #6 Tx B (-) Pin #7 Not Connected Pin #8 Not Connected Figure 8: RS-422 pin-out. nevion.com 12

13 4.3.2 Connecting several frames together Several frames can be connected to each other through the RS-422 ports on the rear of each frame. One GYDA-SC controller can control maximum 8 frames. You start with the frame containing the GYDA-SC Rack System Controller, and use 1 RS- 422 port to loop through to the next. The last frame connected must be terminated with 110 in order to ensure proper operation. The other port of the rack containing the GYDA-SC controller must be left open, and cannot be connected to other frames. Figure 5 shows an example of how to connect 8 frames together as seen from the rear end. By using the RS-422 interface at the GYDA-SC controller card, we control 8 frames via one RS-422 bus. Figure 9: Control of 8 frames with GYDA-SC. The 110 termination plug used is a standard RJ45 plug with the following internal wiring: Figure 10: RS-422 termination. In the figure above, Pin 1 is connected to Pin 2 with a 110 resistor, and Pin 3 is connected to Pin 6 with a 110 resistor. nevion.com 13

14 4.4 Sync input/output. An analog sync signal may be applied to the frame via the Sync in BNC connector.which Flashlink modules that can utilize the sync signal, is described in user manual for the actual modules. While sync is applied, the sync termination switch must be switched to on (upper) position). nevion.com 14

15 5 Frame operation In order to reconfigure or expand the number of modules within a frame, the front panel must be removed. Each module has a corresponding connector module at the rear, and is hot swappable. Use safety goggles when hot-swapping module cards. If a receiver card is removed from the frame, an invisible laser beam may be emitted inside the frame from the laser at the other end. The laser beam might be harmful to your eyes. 5.1 Removing the front panel Pull here "Left circle" Pull here "Right circle" Figure 11: Removing the front panel. nevion.com 15

16 Figure 12: Removing the front panel (continued). 5.2 Backplane insertion Before installing a new Flashlink main module, the accompanying back plane must be mounted. Switch off the power-supply. The LED on the power module is then off. With a redundant solution, make sure that both power supplies are switched off. Remove all screws holding the back plane to be replaced. Remove the backplane by lifting it straight out from the rear of the frame. The backplanes with an optical interface have a rubber plug inside each fiber adapter to protect from dust. This rubber plug must be removed before the backplane is inserted.. Figure 13: Removing the rubber plug from module cards. nevion.com 16

17 When mounting a backplane, the backplane connector shall always be aligned at the left and upper corner pin, see figure 13 below. Alignment pin + Figure 14: Alignment pin If the backplane to be mounted has an EMC gasket of newest type (see fig. 14), the procedure described below does not apply. Figure 15: Newest EMC gasket solution Remove the screws on the back plane to the left of where the new back plane is to be installed (seen from the back of the frame). Lift the right hand side of it slightly. Insert the new back plane. Carefully place the right hand-side of the back plane into the slot first (this is the side without the EMC shielding.) Then, use your business card (or another suitable card), and insert the left edge of the back plane as shown in Figure 15 below. This will help avoid damage to the EMC shield when inserting the new back plane. Figure 16: Inserting a new back plane. After the backplanes are mounted, the main module can be inserted as described in section 5.3 nevion.com 17

18 5.3 Main module insertion After the fan front is removed, full access to the card modules inside the frame is given. Switch off the power with the power switch at the power-supply modules. The green light -- at the power module is now switched off. If the power supply is redundant, make sure that both power supplies are off. The frames are equipped with plastic guide rails to align the module cards into their respective positions 1 to 20. Just before a card is inserted, one should remove the plastic cap from the fiber ferrule as shown in figure 11. Do not touch the ferrule tip with your fingers (see chapter Error! Reference source not found. - fig. 21). Remove plastic cap before inserting module cards a) b) Figure 17: Removal of plastic cap Figure 18: Open frame. nevion.com 18

19 Figure 19: Overview of card positions inside a frame Be careful when inserting the card into the frame. The ferrule of the fiber may be damaged if it touches the frame walls. Do not touch the ferrule tip with your fingers. Figure 20: Marking of main module locations. Figure 21: Inserting module cards. nevion.com 19

20 Figure 22: Inserting module cards (continued) Slide the card into the plastic guide rails inside the frame by pushing at the card edge until the rear edge of the card is locked by the card lock at the end of the card rail. Then push the card handle into vertical position. See sketches below for detailed description. Card locking clip Figure 23: Inserting module cards (continued) Make sure that the connector on the module card fits with the connector on the back plane card when inserting a new module card for the first time. It should not be necessary to use any force when entering the module card into the accompanying back plane connector. nevion.com 20

21 5.4 Card removal To remove a module from the frame, push the spring loaded card lock downwards and below the lower edge of the card. Then, simultaneously with the other hand, move the card handle from vertical to nearly horizontal position and pull the card entirely out of the rack. When removing a receiver card from the frame (hot swapping), the laser beam may be present inside the frame (transmitted through the fiber). To avoid damaging your eyes, never look directly into the frame unless you are 100% sure that no laser beam is present inside the frame. Figure 24: Card removal nevion.com 21

22 5.5 PSU insertion Figure 25: PSU insertion. The outer left and outer right positions are allocated for PSUs. With exception for the lacking card handle the procedure for mounting is similar to main module insertion procedure. In a non-redundant configuration any PSU position may be used. 5.6 PSU removal Figure 26: PSU removal To remove a PSU from the frame, push the spring loaded card lock downwards. Be aware of the PSU connector release force. Then, simultaneously with the other hand, move the metal handle from vertical to nearly horizontal position and pull the PSU entirely out of the rack. nevion.com 22

23 5.7 Attaching the front panel To attach the front panel, we invert the process described in section 5.1. Start by switching on the power supplies. Then move the front to upright position and push it carefully into the frame until it stops. When correctly mounted, both LEDs at the fan front will go through a short start-up sequence before they both provide stable light. Figure 27: Attaching the front panel. nevion.com 23

24 5.8 Frame status (LEDs) PSU status is presented in the following ways: Symbol Green LED Yellow LED Red LED No LED PSU module none Power is OK Voltage or current alarm Power off Frame front Power is OK Communication problem with fan front* Voltage or current alarm Power off** Temperature /fans are OK Communication problem with fan front* Temperature /fans alarm Power off** * Lack of communication with PSU in non-rp mode or one of the PSU s in RP mode. (In both situations the fans will have permanent maximum speed) ** PSU in non-rp mode or both of the PSU s in RP mode Multicon - Multicon GUI which presents the following information o o o o o Measured voltages Measured currents at each frame voltage Total provided power Internal PSU temperature Alarm status for; voltages currents total provided power temperature Defect fan Figure 28: Example of PSU interface in Multicon - GPI o See description in chapter GPI Power Supply Status outputs. nevion.com 24

25 5.9 Fans Fan operation The fans at the front provide sufficient cooling for modules and power supplies in every allowed load situation. Their speed is controlled by control circuits in the power supplies based on their internal temperature. The fan speed is individually and continuously checked, and if a fan has a speed outside expected limits, it will be reported to Multicon as being defective and the lower LED at the fan front will change to red. Having one defective fan in the frame shall not be considered as an emergency situation since the total needed air flow will be maintained by an increase in speed for the remaining fans. Removing the fan front in a live frame may cause malfunction or damage to modules due to excessive heat and should, as a rule, never be done. To maintain optimal cooling, all air flow openings in the chassis must be kept uncovered Replacing defective fans Changing a defective fan should be performed at a non-live frame. Procedure; Please contact Nevion s customer support department. nevion.com 25

26 6 Fiber optics 6.1 Laser safety precautions Guidelines to limit hazards from laser exposure. All the available EO units in the Flashlink range include a laser. Therefore this note on laser safety should be read thoroughly. The lasers emit light at 1270 nm or 1610 nm. This means that the human eye cannot see the beam, and the blink reflex cannot protect the eye. (The human eye can see light between 400 nm to 700 nm). A laser beam can be harmful to the human eye (depending on laser power and exposure time), therefore: Be careful when connecting / disconnecting fiber pigtails (ends). Never look directly into the pigtail of the laser/fiber. Never use microscopes, magnifying glasses or eye loupes to look into a fiber end. Use laser safety goggles blocking light between 1270 nm and at 1610 nm. Instruments exist to verify light output power: Power meters, IR-cards etc. Dette er vel ikke helt oppdatert: Flashlink features: The FR202(-RP) is classified as Class 1 laser product according to EN :94/A11:96, and CFR Ch1(1997) Part If the front panel is removed, the FR202(-RP) is classified as Class 1 laser product according to EN :94/A11:96, and class IIIb according to CFR Ch1(1997) Part Sjekk angående denne spec: Maximum output power: 5 mw.(egentlig 10mW?) Operating wavelengths: 1270 to 1610 nm Figure 29: Laser class label nevion.com 26

27 6.2 Handling of optical fibers When handling fiber optical cables and interconnections, these precautions must be taken to ensure reliable operation: - Do not bend the fiber too much, all fiber optical cables have a minimum bend radius. Follow manufactures datasheet recommendation for each cable or use 40 mm as a general guideline. - Do not apply excessive mechanical stress on the fiber optical cables or connectors. - Keep the connectors clean from dust. Good practice is to clean the ferrule each time a new connection is made between two optical connectors. Always use special fiber optical ferrule cleaner made for this purpose. - Never touch the ferrule or make the tip of the ferrule come in contact with other objects. Always protect ferrules on optical connectors with protective cap when not in use. If the above precautions are not taken, the optical signal may be degraded or even lost completely and the equipment will not function properly. 6.3 Optical connectors The Flashlink product range utilizes among others SC/PC connectors. An illustration of the different parts of the fiber optical connector are shown below. Figure 30: The different parts of an SC/PC Connector. Clean connectors are of crucial for reliable operation. nevion.com 27

28 7 Flashlink control protocol 7.1 Document conventions All commands sent to the card are printed in italics. This is a command sent to a card. All responses sent from a card to the controller are printed in bold. This is a response sent from a card to the controller. 7.2 Hardware interface The hardware interface is basically RS-422, a serial communication standard much like RS- 232 but with balanced lines. You can use a simple (dumb) RS-232 to RS-422 converter if you want to use a standard RS-232 port (eg. a PC COM port). The receive and transmit lines can be connected to make a true RS-485 bus, but this requires special care from the PC side, since you have to control the bus direction (e.g. using a dedicated RS-485 board with RS-485 drivers). We recommend using RS-422 for control. Data rate: bps, 8 bits, with one stop bit and no parity. All data is 8 bit ASCII (ISO encoding, but currently any ASCII encoding will do since no special ASCII characters are used). 7.3 Addressing Each card has a unique identifier called card position, which is assigned (trough hardware pinning) automatically when a card is inserted into a subrack. The card positions are numbered from 1 to 20 from a user point of view. From a protocol (or software) point of view, the cards are numbered When we refer to card position in this document, we refer to this "low level id" numbered 0-19, but the user should always see positions 1-20 in menus, etc. Each frame (if you use more than one) should have a unique frame id, numbered 0-7 (user and protocol/software wise). The id is set by rotary switches on the rear of the rack, behind the power supply at the left side. 7.4 General command structure Each command is built up of a sequence of ASCII characters terminated by linefeed. The first two characters are the source address (source frame id and the source card position). Frame structure: Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 n Byte n+1 Rack ID (0-7); Destination Card position (0-19); Destination Rack ID (0-7); Source Card position (0-19); Source Command or command response Linefeed (10 decimal, 0x0A hex) If the command or command response contains a line feed, it is preceded by a backslash (\). 7.5 Card detection (hot swap) The controller must send a "hello" command to gain control over a board, this is to make sure that the control software is aware of any card changes. After a power up or hot swap, the card does not respond to any other command than hello. nevion.com 28

29 7.6 Hello command This command establishes communication with a new unit. An example of communication with SDI-EO and SDI-OE is shown in the following. The command is short (a single question mark) to save bandwidth. The card will respond with card info. If the card is not present, the command times out. A typical response would be: 0409? 0904EO/SDI/1310nm,-7.5dBm\ hw rev 1.0\ sw rev 1.0\ protocol ver 1.0 This is an electrical to optical converter for SDI, with a -7.5dBm 1310nm laser. The hardware revision is ver 1.0, and the software version is ver 1.0. The protocol version is Electrical to optical converters Hello command An EO converter will respond to a hello command with: 0409? 0904EO/SDI/1310nm,-7.5dBm\ hw rev 1.0\ sw rev 1.0\ protocol ver 1.0 or 0409? 0904EO/T140/1310nm,-7.5dBm\ hw rev 1.0\ sw rev 1.0\ protocol ver Info command The card will respond to the command string "info" by sending the card status. This is a typical example. 0409info 0904laser on\ SDI signal strength = 81 %\ vcc = 5.04 V\ laser fail: no nevion.com 29

30 7.8 Optical to electrical converters Hello command An OE converter will respond to a hello command with: 0409? 0904OE/SDI/reclocking, not calibrated\ hw rev 1.0\ sw rev 1.0\ protocol ver 1.0 or 0409? 0904OE/T140/reclocking, not calibrated\ hw rev 1.0\ sw rev 1.0\ protocol ver 1.0 "Not calibrated" refers to the optical power measurement which is not calibrated Info command The card will respond to the command string "info" by sending the card status. This is a typical example. 0409info 0904signal = dbm\ optical signal: yes\ reclocker locked: yes\ vcc = 4.97V Note that since the optical signal strength is not calibrated, the measurement will be wrong (typ. +/- 5 db). nevion.com 30

31 General environmental requirements for Flashlink equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: - Operating room temperature range: 0 C to 45 C - Operating relative humidity range: < 90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: - Temperature range: -10 C to 55 C - Relative humidity range: < 95% (non-condensing) nevion.com 31

32 Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Nevion, which are available on the company web site: nevion.com 32

33 Appendix A Materials declaration and recycling information A.1 Materials declaration For product sold into China after 1st March 2007, we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. Toxic or hazardous substances and elements 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) <Product> O O O O O O <Power supply, if delivered with unit> O O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T This is indicated by the product marking: A.2 Recycling information Nevion provides assistance to customers and recyclers through our web site Please contact Nevion s Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Nevion or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labeled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices. nevion.com 33

WDM-2 / WDM-2-M. User manual. 2-channel WDM / 2-channel WDM multimode. Rev. D

WDM-2 / WDM-2-M. User manual. 2-channel WDM / 2-channel WDM multimode. Rev. D 2-channel WDM / 2-channel WDM multimode User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support

More information

FR-2RU User manual. Flashlink 2RU frame. Rev. N. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

FR-2RU User manual. Flashlink 2RU frame. Rev. N. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion. Flashlink 2RU frame User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Europe Nevion Support Nevion USA P.O. Box 1020 3204 Sandefjord, Norway Support phone

More information

ETH1000-MKII. User manual. Gigabit Ethernet Media Converter. Rev. A. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

ETH1000-MKII. User manual. Gigabit Ethernet Media Converter. Rev. A. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion. Gigabit Ethernet Media Converter User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone

More information

ETH-1000-SW-10G. User manual. 1-Gigabit Ethernet switch with 10-Gigabit optical uplink port. Rev. D

ETH-1000-SW-10G. User manual. 1-Gigabit Ethernet switch with 10-Gigabit optical uplink port. Rev. D ETH-1000-SW-10G 1-Gigabit Ethernet switch with 10-Gigabit optical uplink port User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O.

More information

HD-SDI Optical to Electrical Converter / HD-SDI Long-haul Optical to Electrical Converter/ HD-SDI Optical to Electrical Converter for multi mode

HD-SDI Optical to Electrical Converter / HD-SDI Long-haul Optical to Electrical Converter/ HD-SDI Optical to Electrical Converter for multi mode Flashlink User Manual HD-OE/HD-OE-L/HD-OE-M HD-SDI Optical to Electrical Converter / HD-SDI Long-haul Optical to Electrical Converter/ HD-SDI Optical to Electrical Converter for multi mode network-electronics.com

More information

CP44-MEC+ CP16-LCD+ CP-MDP-BW+ CP-MDP-CL+

CP44-MEC+ CP16-LCD+ CP-MDP-BW+ CP-MDP-CL+ CP44-MEC+ CP16-LCD+ CP-MDP-BW+ CP-MDP-CL+ VikinX IP-based Control Panels for Multicon User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe

More information

High Definition Electrical to Optical Converter

High Definition Electrical to Optical Converter Flashlink User Manual HD-EO High Definition Electrical to Optical Converter network-electronics.com Rev. 2 Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47

More information

Fast Ethernet Fibre Converter

Fast Ethernet Fibre Converter Flashlink User Manual ETH100 Fast Ethernet Fibre Converter network-electronics.com Rev. 7 Network Electronics ASA Thorøya P.O. Box 1020 N-3204 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99

More information

SL-D32P. User manual. Ported RS-422 Data Router. Rev. 7

SL-D32P. User manual. Ported RS-422 Data Router. Rev. 7 SL-D32P Ported RS-422 Data Router User manual Rev. 7 Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone 2: +47 90 60 99 99 Nevion USA 1600

More information

Control Panels in the VikinX Sublime series. User manual

Control Panels in the VikinX Sublime series. User manual Control Panels in the VikinX Sublime series User manual Rev. 5 Nevion Europe AS P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com Nevion Support Nevion Europe

More information

Flashlink User Manual DLY-AES. Dual AES Audio Delay. network-electronics.com. Rev. 3

Flashlink User Manual DLY-AES. Dual AES Audio Delay. network-electronics.com. Rev. 3 Flashlink User Manual DLY-AES Dual AES Audio Delay network-electronics.com Rev. 3 Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 E-mail: support@network-electronics.com

More information

Multicon VX-MOD. VikinX Modular System Controller. User manual. Rev. 0

Multicon VX-MOD. VikinX Modular System Controller. User manual. Rev. 0 Multicon VX-MOD VikinX Modular System Controller User manual Rev. 0 Nevion Europe AS P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com Nevion Support Nevion

More information

CONV-SFP-4. User manual. Quad Channel SFP Converter supporting Video and GbE SFPs. Rev. B

CONV-SFP-4. User manual. Quad Channel SFP Converter supporting Video and GbE SFPs. Rev. B Quad Channel SFP Converter supporting Video and GbE SFPs User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord,

More information

VikinX Modular Analog Audio Router

VikinX Modular Analog Audio Router r VikinX User Manual A3232M/A6464M/A128128M/A3232S/A6464S VikinX Modular Analog Audio Router network-electronics.com Rev. 8 Network Electronics AS Nordre Kullerød 1 P.O. Box 1020 Sandefjord, Norway Phone:

More information

Analog Stereo Audio Routers in the VikinX Sublime series. User manual

Analog Stereo Audio Routers in the VikinX Sublime series. User manual Analog Stereo Audio Routers in the VikinX Sublime series User manual Rev. 14 Nevion Europe AS P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com Nevion Support

More information

VikinX Modular 256x256 Router

VikinX Modular 256x256 Router r VikinX User Manual FR-256256-MR / VD256256L / HD256256L VikinX Modular 256x256 Router network-electronics.com Rev. 1 Network Electronics ASA Thorøya P.O. Box 1020 N-3204 Sandefjord, Norway Phone: +47

More information

USER MANUAL FR-CWDM. flashlink Coarse Wavelength Division Multiplexing System. Rev. 1

USER MANUAL FR-CWDM. flashlink Coarse Wavelength Division Multiplexing System. Rev. 1 Rev. 1 USER MANUAL FR-CWDM flashlink Coarse Wavelength Division Multiplexing System Network Electronics ASA Thorøya 3230 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 e-mail: support@network-electronics.com

More information

AES/EBU Digital Audio Routers VikinX Sublime series

AES/EBU Digital Audio Routers VikinX Sublime series AES/EBU Digital Audio Routers VikinX Sublime series User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord,

More information

SL-3GHD RC. User manual. VikinX Sublime 128x128 3G/HD-SD-SDI Router. Rev. A

SL-3GHD RC. User manual. VikinX Sublime 128x128 3G/HD-SD-SDI Router. Rev. A VikinX Sublime 128x128 3G/HD-SD-SDI Router User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway

More information

Telecom Routers in the VikinX Sublime series

Telecom Routers in the VikinX Sublime series r VikinX User Manual SL-T6464(-CP)/SL-T3232(-CP) SL-T1616(-CP)/SL-T0808(-CP) Telecom Routers in the VikinX Sublime series network-electronics.com Rev. 0 Network Electronics AS Nordre Kullerød 1 P.O. Box

More information

Analog Video Routers in the VikinX Sublime series. User manual

Analog Video Routers in the VikinX Sublime series. User manual Analog Video Routers in the VikinX Sublime series User manual Rev. 16 Nevion Europe AS P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com Nevion Support Nevion

More information

3G/HD/SD-SDI Video Routers in the VikinX Sublime series. User manual

3G/HD/SD-SDI Video Routers in the VikinX Sublime series. User manual 3G/HD/SD-SDI Video Routers in the VikinX Sublime series User manual Rev. 21 Nevion Europe AS P.O. Box 1020, 3204 Sandefjord, Norway Tel: +47 33 48 99 99 Fax: +47 33 48 99 98 www.nevion.com Nevion Support

More information

3G/HD/SD-SDI Video Routers VikinX Sublime Series

3G/HD/SD-SDI Video Routers VikinX Sublime Series 3G/HD/SD-SDI Video Routers VikinX Sublime Series User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord,

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

Ground Master Monitor Installation, Operation and Maintenance

Ground Master Monitor Installation, Operation and Maintenance USER GUIDE TB-9078 Ground Master Monitor Installation, Operation and Maintenance Made in the United States of America The Ground Master Monitor and its accessories are available as the following item numbers:

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL

DVBus , and Multiplexer and demultiplexer assemblies for video channels USER MANUAL DVBus 8050-16, 8050-24 and 8050-32 Multiplexer and demultiplexer assemblies for 16-32 video channels USER MANUAL 1. Description DVBus 8050 systems transmit 10-bit digitized video signals over one optical

More information

Multicon Upgrade Guide

Multicon Upgrade Guide User manual Nevion Nordre Kullerød 1 3241 Sandefjord Norway Tel: +47 33 48 99 99 nevion.com Nevion Support Nevion Europe P.O. Box 1020 3204 Sandefjord, Norway Support phone 1: +47 33 48 99 97 Support phone

More information

TCF-142-RM Series Hardware Installation Guide

TCF-142-RM Series Hardware Installation Guide TCF-142-RM Series Hardware Installation Guide Third Edition, March 2015 2015 Moxa Inc. All rights reserved. P/N: 1802001420622 *1802001420622* Overview Introduction The TCF-142-RM series fiber converters

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

LASER PLUS OPERATING INSTRUCTIONS

LASER PLUS OPERATING INSTRUCTIONS LASER PLUS OPERATING INSTRUCTIONS Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com 025-370403 REV X9 www.olsontech.com 12/16/03 TABLE OF CONTENTS SYSTEM OVERVIEW

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Fifth Edition, July 2015 2015 Moxa Inc. All rights reserved. P/N: 1802011500014 1802011500014 Overview Introduction ICF-1150 series fiber converters have a multi-interface

More information

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL

OTEB-CO-B Series. Booster EDFA OPERATING MANUAL OTEB-CO-B Series Booster EDFA OPERATING MANUAL 24926 Highway 108 Sierra Village, CA 95346 Phone: (800) 545-1022 Fax: (209 586-1022 025-000533 Rev X6 E-Mail: sales@olsontech.com 27 Apr 2010 TABLE OF CONTENTS

More information

PTC-101 Quick Installation Guide

PTC-101 Quick Installation Guide PTC-101 Quick Installation Guide Moxa Industrial Media Converter Edition 5.1, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Medallion 7200 Series CATV Fiber Amplifier

Medallion 7200 Series CATV Fiber Amplifier MODEL Medallion 7200 Series CATV Fiber Amplifier ERBIUM/YTTERBIUM DOPED FIBER AMPLIFIER (EYDFA) The Medallion 7200 series product line is a family of state-of-the-art high performance CATV Erbium/Ytterbium

More information

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

PTC-101-M12 Hardware Installation Guide

PTC-101-M12 Hardware Installation Guide PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter Third Edition, May 2014 2014 Moxa Inc. All rights reserved. P/N: 1802001016021 Overview The PTC-101-M12 industrial media converter

More information

NPort 5400 Series Quick Installation Guide

NPort 5400 Series Quick Installation Guide NPort 5400 Series Quick Installation Guide Edition 7.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Cisco Prisma II Platform

Cisco Prisma II Platform Cisco Prisma II Platform In optical transmission systems, the network platform forms the foundation of the product family. The Cisco Prisma II platform provides network operators with the unique features

More information

Serial Data DIN Fiber Link System

Serial Data DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-120 2017A-0420 DIN Fiber Link System COMPACT, RUGGED & TEMPERATURE HARDENED Introduction The DIN Fiber Link system transports

More information

PCD 005 PolaMIX. Operation Manual

PCD 005 PolaMIX. Operation Manual PCD 005 PolaMIX All-Fiber Polarization Scrambler Module with Microprocessor Controller Operation Manual July 29, 2011 General Photonics Corp. Ph: (909) 590-5473 5228 Edison Ave. Fax: (909) 902-5536 Chino,

More information

Flashlink Dense Wavelength Division Multiplexing System

Flashlink Dense Wavelength Division Multiplexing System Flashlink User Manual FR-DWDM Flashlink Dense Wavelength Division Multiplexing System network-electronics.com Rev. 7 Index Revision history...5 1 General information...6 1.1 Handling of optical fibers...6

More information

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide First Edition, February 2012 2012 Moxa Inc. All rights reserved. P/N: 1802001016020 Overview Moxa Industrial Media Converter, which

More information

DXF-200 DVI/HDMI Optical Extension System

DXF-200 DVI/HDMI Optical Extension System DXF-200 DVI/HDMI Optical Extension System User s Manual M916-9900-102 17 February 2010 Miranda Technologies Inc. 3499 Douglas-B.-Floreani St-Laurent, Québec, Canada H4S 1Y6 Tel. 514-333-1772 Fax. 514-333-9828

More information

Prisma II Platform. Optoelectronics

Prisma II Platform. Optoelectronics Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the

More information

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM

6100E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM 00E Series DIGITAL FIBER OPTIC MULTI-CHANNEL AUDIO TRANSPORT SYSTEM WITH DATA OPTIONS BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

IFS MCR-R15 Media Converter Rack User Manual

IFS MCR-R15 Media Converter Rack User Manual IFS MCR-R15 Media Converter Rack User Manual P/N 1076518 REV A ISS 08FEB12 Copyright Trademarks and patents Manufacturer Version Certification FCC compliance ACMA compliance European Union directives 2012

More information

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G) Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches Installation Guide P/N 5500339-10 (Rev G) Overview This document contains instructions necessary for the installation and operation of the Perle IDS-108F

More information

IMC-21 Quick Installation Guide

IMC-21 Quick Installation Guide IMC-21 Quick Installation Guide Moxa Industrial Media Converter Edition 5.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

TABLE OF CONTENTS 1. OVERVIEW... 1

TABLE OF CONTENTS 1. OVERVIEW... 1 TABLE OF CONTENTS 1. OVERVIEW... 1 1.1. SPECIFICATIONS... 1 1.1.1. Electrical... 1 1.1.2. Compliance... 2 1.1.3. Physical... 2 1.2. COOLING... 2 1.2.1. Fan Exhaust... 2 1.3. MOUNTING... 3 1.4. POWER...

More information

Installing Power Modules

Installing Power Modules This chapter contains the procedures for installing cards and modules into the chassis after the chassis has been installed into a rack. This chapter also describes how to connect cables to RSP, RP, alarm,

More information

Medallion 7200 Series CATV Fiber Amplifier

Medallion 7200 Series CATV Fiber Amplifier The Medallion 7200 series product line is a family of state-of-the-art high performance CATV Erbium/Ytterbium Doped Fiber Amplifiers (EYDFA). Packaged in a convenient 2 RU housing, this line of fiber amplifiers

More information

PT-7728/7828 Quick Installation Guide

PT-7728/7828 Quick Installation Guide PT-7728/7828 Quick Installation Guide Moxa PowerTrans Switch Edition 9.0, April 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide Industrial Serial RS-232 to Fiber Converter KSC-200 Series Installation Guide DOC.100803-KSC-200-1- (C) 2006 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any

More information

Features and Benefits. Certifications

Features and Benefits. Certifications TCF-142 Series RS-232/422/485 to fiber converters Features and Benefits Ring and point-to-point transmission Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF- 142-S) or 5 km with multi-mode

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX

8 Chanel HD SDI Over Fiber. Transmitter and Reciever Extender. User Manual L-8SDI-FE-HD-TX/RX 8 Chanel HD SDI Over Fiber Transmitter and Reciever Extender User Manual L-8SDI-FE-HD-TX/RX Contents CHAPTER 1. INTRODUCTION... 2 1.1 OVERVIEW...2 1.2 FEATURE...2 1.3 APPLICATION...3 CHAPTER 2. L-8SDI-FE-HD-TX/RX

More information

Operation Instruction for CNI Model with PSU-III-LCD

Operation Instruction for CNI Model with PSU-III-LCD Operation Instruction for CNI Model with PSU-III-LCD Caution-Use of controls or adjustments or performance of procedures other than those specified in this manual may result in hazardous radiation exposure.

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

Installing the MWAM CHAPTER

Installing the MWAM CHAPTER CHAPTER This chapter provides information about installing the MWAM in a Catalyst 600/Cisco 7600 chassis and includes the following topics: Safety Recommendations, page -2, page - Verifying the Installation,

More information

User Manual Controller. Automation and Router Control.

User Manual Controller. Automation and Router Control. User Manual 2460 Controller Automation and Router Control www.s-a-m.com 2460 Controller User Manual www.s-a-m.com Contents Contents 1. Information and Notices.................................................

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

3 Angled Connector Housing (MC) Installation

3 Angled Connector Housing (MC) Installation Angled Connector Housing (MC) Installation Instructions July 1999 4-7047-2554-7 MC Frame Figure 1 Angled Connector Housing (MC) General This document describes the installation of the stubbed MC Angled

More information

Multimode Laser-532 Installation and Operation Manual

Multimode Laser-532 Installation and Operation Manual Multimode Laser-532 Installation and Operation Manual For Products: Model LASER-532-IP-LAB Document: 000-31000-010-02-201503 WARNING Protective Eye Wear Should Be Worn When Using This Instrument - Intense

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

Summit Virtual Chassis Design and Installation Guide

Summit Virtual Chassis Design and Installation Guide Summit Virtual Chassis Design and Installation Guide Extreme Networks, Inc. 10460 Bandley Drive Cupertino, California 95014 (888) 257-3000 http://www.extremenetworks.com Published: June 1998 Part No: 120031-00

More information

Power Enclosure Components

Power Enclosure Components Power Enclosure Components HP BladeSystem p-class 1U Power Enclosure Exploded View Figure 1-5 HP BladeSystem p-class 1U power enclosure exploded view Illustrated Parts Catalog 20 HP BladeSystem p-class

More information

NPort 6600 Series Quick Installation Guide

NPort 6600 Series Quick Installation Guide NPort 6600 Series Quick Installation Guide Edition 10.0, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

KOM600/KOM600G Fiber Media Converter Hardware Installation Manual

KOM600/KOM600G Fiber Media Converter Hardware Installation Manual KOM600/KOM600G Fiber Media Converter Hardware Installation Manual Kyland Technology Co., LTD. Publication Date: Dec. 2012 Version: V1.1 Customer Service Hotline: (+8610) 88796676 FAX: (+8610) 88796678

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

Installing the ASA 5550

Installing the ASA 5550 CHAPTER 3 Installing the ASA 5550 Caution Read the safety warnings in the Regulatory Compliance and Safety Information for the Cisco ASA 5500 Series and follow proper safety procedures when performing

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

Installing ONS SDH OC3 IR 4/STM1 SH 1310 Cards

Installing ONS SDH OC3 IR 4/STM1 SH 1310 Cards Installing ONS 15454 SDH OC3 IR 4/STM1 SH 1310 Cards Product Name: 15454E-S1.1-4= This document contains a description of OC3 IR 4/STM1 SH 1310 card features, installation procedures, removal instructions,

More information

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual KIEN2204S Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co., Ltd. Publication Date: Mar. 2013 Version: V1.0 FAX: +86-10-88796678 Website: http://www.kyland.com E-mail: support@kyland.com

More information

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL

OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL OTEB-CO-P PRE-AMP EDFA INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 E-Mail: salessupport@olsontech.com www.olsontech.com 025-000521 Rev. X1 10/01/2012 SAFETY WARNINGS LASER

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

PSW-002. Fiber Optic Polarization Switch. User Guide

PSW-002. Fiber Optic Polarization Switch. User Guide PSW-002 Fiber Optic Polarization Switch User Guide Version: 1.1 Date: June 30, 2015 General Photonics Corporation is located in Chino California. For more information visit the company's website at: www.generalphotonics.com

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

IMC-21GA Quick Installation Guide

IMC-21GA Quick Installation Guide IMC-21GA Quick Installation Guide Moxa Industrial Media Converter Edition 4.0, June 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Installation Job Aid for Ethernet Routing Switch 5900 Series

Installation Job Aid for Ethernet Routing Switch 5900 Series Installation Job Aid for Ethernet Routing Switch 5900 Series Notices NN47211-301 Issue 05.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

TCF-142 Quick Installation Guide

TCF-142 Quick Installation Guide TCF-142 Quick Installation Guide Edition 15.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

IMC-21A Quick Installation Guide

IMC-21A Quick Installation Guide IMC-21A Quick Installation Guide Moxa Industrial Media Converter Edition 5.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

EMSwitch RF Switch Plug-In Card

EMSwitch RF Switch Plug-In Card EMSwitch RF Switch Plug-In Card User Manual Model 7001-001 Model 7001-003 Model 7001-002 (not all models shown; Model 7001-004 External Switch Box not shown) ETS-Lindgren Inc. reserves the right to make

More information

MGate MB3170/MB3270 Quick Installation Guide

MGate MB3170/MB3270 Quick Installation Guide MGate MB3170/MB3270 Quick Installation Guide Edition 7.1, February 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

RS-232 Industrial Media Converter

RS-232 Industrial Media Converter USER GUIDE The leader in rugged fiber optic technology. U-151 2018C-0327 Industrial Media Converter COMPACT, RUGGED & TEMPERATURE HARDENED Introduction This Industrial Serial Data media converter transports

More information

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES KEPCO INC. An ISO 9001 Company. MODEL RA 55 RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual is valid for

More information

Switched Uplink Modules

Switched Uplink Modules APPENDIX D Switched Uplink Modules When installed in a FastHub 400 model, each 10BaseT/100BaseTX and 100BaseFX switched uplink module provides a separate switched collision domain for traffic to the workgroup

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

RS-422/485 to Fiber Industrial Converter

RS-422/485 to Fiber Industrial Converter RS-422/485 to Fiber Industrial Converter (IRF-612) User s Guide COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems. DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3

More information

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial 3-Port Fast Ethernet Media Converter Switches Industrial 3-Port Fast Ethernet Media Converter Switches KSD-103-A series KSD-103-B series Installation Guide DOC.081111 1/20 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation

More information