Intrinsically Safe Remote I/O System

Size: px
Start display at page:

Download "Intrinsically Safe Remote I/O System"

Transcription

1 Intrinsically Safe Remote I/O System Sits directly in a Division or Zone location Intrinsically safe remote I/O system for field devices located in Division and Zone 0 locations Redundant power supplies and gateways Intrinsically safe connection to PROFIBUS-DP with V functionality Online programming and configuration of all parameters Initial HART operating parameters set consistently from process control system to field device Temperature range from -0 to 0 C (- to 0 F) Hot swapping of all components during operation Simple one-hand insertion and removal of I/O modules without tools discrete or analog intrinsically safe channels via a single bus address "Forcing" and substitute value programming of analog and discrete I/O TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

2 excom System Overview Device Features Part Number Page Type of Device Type of Input Type of Output Number of Inputs Number of Outputs Short-Circuit Monitoring Wire-Break Monitoring Min./Max. Current [ma] Maximum Voltage [V] Initial Operating Parameters Set Software Product Range GDP. DF0Ex AIH0Ex AIHEx TI0Ex 0 0 gateway I/O module module I module I module I module NAMUR NAMUR analog analog analog discrete discrete -/ -/ 0()/0 0()/0 -/ GSD DO0Ex AO0Ex O module O module discrete analog 0()/0.9.9 MT/MT9/MT backplane PSDEx supply Page Gateways Input/Output Modules 0 Input Modules Output Modules Backplanes Power Supplies TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

3 Intrinsically Safe Remote I/O System System Overview excom is a remote I/O system for use in potentially explosive hazardous locations. It features bus-compatible, decentralized input and output modules in IP 0 housings that support discrete and analog intrinsically safe field devices. The modules are approved for use in Division, Zones and. The system consists of power supplies, gateways, I/O modules and a backplane. The backplane serves to distribute energy, transmit data and connect field devices. The power supply units ensure that reliable power is supplied to the entire system. A single power supply is sufficient for correct system operation. However, in order to enhance system availability, a second supply may be connected for redundancy. The gateways fulfill both master and slave functions: as a master they control the internal data bus and as a slave they communicate with the higher level fieldbus. Gateways control data communication between an I/O module and the process control system (PLC). The excom system may be configured with redundant gateways. The I/O modules act as interfaces to the intrinsically safe field devices. They receive intrinsically safe power from the supply units via the backplane. Up to I/O modules may be operated within a single backplane. Modules are easily connected: gateways, power supplies and I/O modules are simply plugged onto the backplane and latched. After the internal connections have been established, the peripheral components may be connected. The modules are hot-swappable. They may be plugged onto and removed from the backplane during operation in hazardous locations. When replacing faulty modules, the system automatically checks whether the previous module and the replacement are identical. The system supports substitute value programming. The internal cycle time of a fully assembled system is below ms (discrete processing; analog signals < 0 ms). The response time also depends upon the type of control system and fieldbus used in the application. If this is too long for some applications, it is possible to carry out direct assignments from inputs to outputs and to configure small function blocks within the system (PID in preparation). The system supports HART-compatible field devices; PROFIBUS-DP-V enables HART communication with the PLC. System Configuration redundant power supply bus address setting via coded rotary switches open I/O modules in various designs integrated rails for module mounting, coding gold-plated connectors for connection of I/O modules backplane LEDs for status/ I/O status indications two redundant gateways possible connection of external supply voltage connection of higherlevel field bus connection of field devices module front cap with mechanical coding TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

4 Required Components for System Assembly In order to assemble a system, the following components are required as a minimum: () MT or MT9 or MT backplane () PSDEx power supply ( VDC) () GDP. PROFIBUS-DP gateway,. Mbps Then choose from the following discrete or analog input and output modules based upon the application: DF0Ex DO0Ex AIH0Ex AIHEx TI0Ex AO0Ex discrete input/output module for connection of NAMUR sensors and low voltage actuators discrete input module for frequency/counter function discrete output module for connection of intrinsically safe solenoid valves < W analog input module for connection of -wire transmitters with HART functionality analog input module for connection of -wire transmitters with HART functionality analog input module for connection of temperature detectors analog output module for connection of analog actuators PLC/SPC Connection excom may be connected to all systems withprofibus-dp interface (master functionality). In order to obtain access to the full range of functions, a PROFIBUS-DP master with V functionality should be used. Connections Bus: The MT backplane contains two 9-pole D-SUB connectors (redundant) and the MT and MT9 backplanes contain one 9-pole D-SUB connector for bus c onnection. Either copper cables conforming to PROFIBUS-DP specifications or fiber optics with matching transducers may be used. When mounting in a hazardous location, applicable precautionary measures must be used (see Installation Guidelines). Power supply: The standard backplane for Zones and features EEx e terminals for power supply connection. Modules: The modules are connected via two connectors ( poles / poles) with the backplane. Inputs/outputs: The backplane contains four -pole connectors per I/O module for connection to field devices. Several connection methods may be used, such as cage clamp terminals, screws, etc. Please consider the connection options when ordering components. Caution: All applicable regulations governing hazardous-location installations must be observed. TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

5 Intrinsically Safe Remote I/O System Diagnostics The gateway provides extended PROFIBUS-DP diagnostics, i.e. the full range of diagnostic data including channel-specific error indications. Each module is equipped with LEDs for field error indication. All I/O modules also feature LEDs for input/ output diagnosis and status indication. LED indications conform to NAMUR NE or DIN EN 00, i.e. Additional details are contained in the operating manual. green = operational readiness (power on/module function) red = error yellow = switching stat us of binary inputs/outputs Addressing The modules are addressed according to their physical location, thereby eliminating any need for manual addressing. A module inserted into slot 0 is assigned the internal address 0, a module in slot is assigned to address, etc. Three coded rotary switches are used to set the rack s PROFIBUS-DP address (maximum ). PROFIBUS-DP sees the system as a variable slave. Therefore, only the I/O modules physically present are assigned addresses by the PLC or process control system. Communication Rates / Cycle Times The PROFIBUS-DP master determines the system-specific communication rate. Admissible comm rates range from 9. to 00 kbps. The internal cycle time to process discrete signals is less than ms; to process analog signals requires less than 0 ms. The response time of the entire system largely depends on the number of PROFIBUS-DP nodes and the processing time of the higher level system. The general formula is: T R = x T I x T B x T PLS T R = response time; T I = internal cycle time Ex link; T B = cycle time of higher level bus; T PLS = cycle time of process control system. Software/System CD Included in Delivery device database file (GSD file) or Download from Worldwide Headquarters in Germany Support excom Utilities TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

6 Maximum System Extension PROFIBUS-DP allows no more than nodes to operate on one segment (including the master). The use of repeaters enables the operation of nodes with one PROFIBUS-DP master. Each segment may only be operated with the specified comm rate and maximum cable length. No more than four repeaters may be used on a network above 00 kbps. At 00 kbps and below up to seven repeaters may be used. The maximum cable lengths (without repeaters) depending on the communication rate are shown in the table below: Comm Rate Bus Segment Repeater Nodes (length of bus line) (max. number) (max. number) 9. kbps 9 ft (00 m) 9. kbps 9 ft (00 m) 9. kbps 9 ft (00 m). kbps ft (000 m) 00 kbps ft (00 m) Installation Guidelines excom is a remote I/O system to be installed in Division, Zone or Zone hazardous locations with intrinsically safe connections to field devices in Division or Zone 0 locations. The excom system communicates with a control system via PROFIBUS-DP. When using copper cables an approved segment coupler must be used. In this case, only ten excom systems may be used with one segment coupler. The use of fiber optics is also permitted. If redundancy is required, two gateways may be installed. The power supply is connected via EEx e (increased safety) terminals. The power supply may be installed and exchanged during operation. Please observe standard safety regulations regarding terminal connections. Field components such as sensors and actuators located in the hazardous location connect to the I/O modules via terminals. The modules are rated for connection to devices in Division or Zone 0 (protection type EEx ib[ia] IIC T) and provide secure galvanic isolation. Modules, sensors and actuators may be exchanged hot. If the system is installed in a hazardous location, suitable field housings are required. It is possible to order devices in appropriate field housings to ensure that the required protection type is fulfilled. All modules, the gateway to the higher level fieldbus and the power supply carry separate approvals. They may only be used in conjunction with approved backplanes. TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

7 DO0Ex DO0Ex DO0Ex DO0Ex PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X DO0Ex DO0Ex DO0Ex DO0Ex PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X PTB 00 ATEX 0000 X DO0Ex DO0Ex Intrinsically Safe Remote I/O System The GDP. gateway serves to connect the excom system to the PROFIBUS- DP network. It is intrinsically safe and may be installed in Division, Zone or Zone hazardous locations without additional protective measures. Copper cables or fiber optics (requiring additional module) may be used to connect the gateway to the PROFIBUS-DP network. When using copper cables an approved segment coupler must be used on the PROFIBUS-DP side to ensure explosion protection. The gateway may be configured for a maximum comm rate of 00 kbps. It does not feature a mechanical interface to the PROFIBUS-DP. Two standard miniature D-SUB connectors on the module rack connect the excom system to the bus. This arrangement allows gateways to be exchanged without interrupting bus communication and enables redundant system configuration. To reduce response times and facilitate control system operation, the gateway performs input and output assignment. A GSD file for system configuration is available from TURCK and included with each system. Redundancy: The use of two gateways and two bus lines ensures error-free, continuous communication. Should one of the gateways or bus lines fail, the other immediately takes over. GDP. Intrinsically safe gateway for PROFIBUS-DPV Redundant configuration possible Up to I/O modules per gateway Cycle times: < ms (discrete) < 0 ms (analog) LED indications for operational readiness CAN internal bus communication PROFIBUS-DP communication configuration errors redundancy stand-by Connections PROFIBUS-DP via D-SUB connectors Principle of operation: The primary active gateway is inserted into slot 0. The gateway in slot is in stand-by mode and monitors data communication in both directions, i.e. data transfer to the PROFIBUS-DP master and to the I/O modules. Both gateways check their data for consistency. If variations exist, e.g. a bus line is disconnected or a gateway does not receive messages, the other gateway becomes active and generates an error indication via the PROFIBUS-DP. Recommended connection components: PROFIBUS-DP: DT9-Ex, (9-pin D-Sub) PLC segment coupler Ex separation TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

8 Gateway GDP. PROFIBUS-DP Interface Type ID Number GDP. M00 Power Supply from central power supply via module rack Internal power consumption < W Galvanic isolation to PROFIBUS-DP V pp (per EN 000) Connections PROFIBUS-DP Supply 9-pole D-SUB connector on module rack via connectors on module rack Ex Approval PTB 00 ATEX Factory Mutual II G SYST EEx ib IIC T A Ex e m i b {ia] IIC T RS field bus connection (terminal pair) Suitable for C, Div, Grps A, B, C, D Protection type EEx ib IIC/IIB Haz. Loc.(Temp Code T) with I/S entity connections to C, Div, Grps A, B, C, D; C, Div., Maximum values Grps E, F, G; C, Div Haz. Loc. No-load voltage U 0 /V 0c. V Short-circuit current I 0 /ISC ma Maximum Power P 0 mw Typical curve linear - U i. V External RS field bus system Protection Type SYST EEx ib IIC/IIB Maximum values per terminal pair - U i. V Accumulated max. value of terminal pairs - I i. V Cables: cable type A or B to EN L'/R'. H/ (loop resistance) - C' 0 nf/km Litz wire diameter 0. mm lumped inductances adn capacitances within the fieldbus system are not admissible LED Indications Power/Fault CAN Internal bus communication PROFIBUS-DP communication Configuration green/red (dual color LED) yellow yellow yellow red General Data Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to 0 F) Dewing for a short period only (during system set-up) TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: ()

9 Intrinsically Safe Remote I/O System The is an eight-channel discrete input/output module designed for connection to NAMUR sensors, mechanical contacts, or low power actuators. If mechanical contacts are connected and monitored for wire-break and short-circuit, a resistor circuit must be used (TURCK model WM, ID# 090). The module is approved for Zone /Division hazardous locations with connections to approved field devices or simple apparatus in Zone 0/Division. No additional protective measures are required for connected field devices. When connecting field devices, please observe that all inputs/outputs operate at the same potential e.g. there is no galvanic isolation between channels. It is possible to configure circuit monitoring, failsafe mode, polarity, and damping for the entire module using any standard PROFIBUS-DP master and the system GSD file. The software tool excom design or a PROFIBUS-DP master with V functionality enables the configuration of these parameters separately for each channel. Additionally, the eight channels of the can be configured as follows: inputs/0 outputs, inputs/ output..., 0 inputs/ outputs This allows greater flexibility in configuring the system per application requirements. Input/output module for NAMUR sensors and actuators Zone /Division hazardous location approval with connections to approved field devices in Zone 0/ Division Connections for up to NAMUR sensors or mechanical contacts Connections for up to low-power actuators (low-power valves) Short-circuit and wire-break detection Galvanic isolation between input, bus and power supply Inputs and outputs at one common potential Configurable input or output function Connections Inputs and outputs via MINI COMBICON plug-in terminals; versions available with screw, crimp or cage-clamp connections terminal configuration channel channel channel channel channel channel channel channel connection possibilities (selectable) BN BU BN BU BN BU BN BU 0 TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

10 Discrete Input/Output Module Input NAMUR/ Output Type ID Number Power Supply Internal power consumption Galvanic isolation Inputs Input voltage Input current Switching threshold ON/OFF Switching frequency Short-circuit threshold Wire-break threshold Outputs Output voltage Nominal output current Internal resistance Switching frequency Short-circuit threshold Wire-break threshold M00 from central power supply via module rack < W to bus and to supply () NAMUR sensors or dry contacts VDC approx. ma per input. ma/. ma < 00 Hz R a < Ω < 0. ma () low-power actuators VDC ma per output 0 Ω < 00 Hz R a < Ω < 0. ma Ex Approval PTB 00 ATEX Factory Mutual Marking II () G EEx ib [ia] IIC T A Ex e m i b [ia] IIC T. Suitable for Max. Ex values (fieldbus circuits) EEx ia IIC/IIB C, Div, Grps A, B, C, D Haz. Loc. (Temp Code T) with I/S entity connections No-load voltage U 0 /V oc 9. V to C, Div, Grps A, B, C, D; C, Div., Short-circuit current I 0 /I SC ma Grps E, F, G; C Div Haz. Loc. Max. power P 0 0 mw Typical curve linear Max. internal capacitances L i negligible Max. internal capacitances C i negligible Max. external capacitances L 0 /L a see diagram to right Max. external capacitances C 0 /C a see diagram to right Initial Operating Parameters Bounce time Inputs/outputs Wire-break monitoring Short-circuit monitoring Function mode Substitute value programming LED Indications Power on/module function Input/output status 0-0 ms for groups of two channels for groups of two channels for groups of two channels for groups of two channels inputs separately programmable for group of two-channels for groups of two channels green/red (dual color LED) () yellow/red (dual color LED) General Data Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to 0 F) Dewing for a short period only (during system set-up) TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

11 Intrinsically Safe Remote I/O System The DF0Ex is equipped with eight channels according to NAMUR, which are divided into two blocks. There is one frequency input and three control inputs/ outputs per block. The module is approved for Zone /Division hazardous locations with connections to approved field devices or simple apparatus in Zone 0/Division. No additional protective measures are required for connected field devices. When connecting field devices, please observe that all inputs/outputs operate at the same potential - e.g. there is no galvanic isolation between channels. The module can be used as a counter or frequency input module and is thus suited for pulse counting of binary input signals or frequency measurements of binary pulse sequences of NAMUR sensors. The counting direction can eithr be set externally via the control input or parameterised internally. The maximum frequency of one block is khz; with blocks the maximum frequency is reduced to khz. The input and output performance is programmed via the PROFIBUS master. Each channel is equipped with a parameterisable wire-break and short-circuit monitoring function. DF0Ex channel BN BU - Intrinsically safe frequency module for connection of intrinsically safe NAMUR sensors Zone /Division hazardous location approval with connections to approved field devices in Zone 0/ Division Operating modes: counter and frequency input Control inputs for direction detection, usable as a reset or enable input Short-circuit and wire-break detection Galvanic isolation between input and output block, bus and power supply Inputs and outputs at one common potential Connections Inputs and outputs mini combination plug-in terminals, versions available with screw, crimper or cage-clamp connection channel channel channel channel channel channel channel BN BU - counter DIR - DIR - GATE - GATE - RST - RST - frequency DIR DIR DIR-OUT DIR-OUT ZERO ZERO TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

12 Type DF0Ex ID Number M 0 Input Module DF0Ex inputs for frequency generators Power Supply Internal power consumption Galvanic isolation from central power supply via module rack <. W to bus and to supply Inputs channels according to NAMUR (DIN EN 0 9--) Input voltage VDC Input current approx. ma Switch-on/off threshold. ma/. ma Internal resistance 0 Ω Min. switching frequency > 0. Hz Max. switching frequency < khz/ khz Short-circuit threshold R a < Ω Wire-break threshold < 0. ma Ex Approval PTB 00 ATEX Marking II () G EEx ib [ia] IIC T Max. Ex values (fieldbus circuits) EEx ia IIC/IIB No-load voltage U 0 /V oc 9. V Short-circuit current I 0 /I SC ma Max. power P 0 0 mw Typical curve linear Max. internal capacitances L i negligible Max. internal capacitances C i negligible Max. external capacitances L 0 /L a see diagram to right Max. external capacitances C 0 /C a see diagram to right Initial Operating Parameters Operating Mode Wire-break monitoring Short-circuit monitoring Substitute value programming Counting direction Direction detection Inversion Damping of control signals Gate input Average forming Accuracy -Resolution LED Indications Power on/module function Input/output status Counter or frequency input, per module per block per block per block per block per block per block per block 0.% of actual measuring value with a peak time of 00 ms or % of actual measuring value with a peak time of 0 ms green/red (dual color LED) () yellow/red (dual color LED) General Data Enclosure IP 0 Operating temperature -0 to 0 C (- to 0 F) Relative humidity 9% at C according to EN 00- Vibration and shock testing according to IEC -- and IEC -- TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

13 Intrinsically Safe Remote I/O System The AIH0Ex is a four-channel analog input module designed for connection to HART-compatible -wire -0 ma transmitters or 0/-0 ma current sources. The module can be configured to allow HART communications signals to pass through unimpeded. A transmitter supply voltage of >.0 V at ma is provided to power -wire transmitters. The module is approved for Zone / Division hazardous locations with connections to approved field devices in Zone 0/ Division. No additional protective measures are required for connected field devices. The resolution is -bits, i.e. the analog value of 0- ma is represented as a number between 0 and. Data representation depends upon the type of control system used. When connecting field devices, please observe that all inputs operate at the same potential e.g. there is no galvanic isolation between channels. Using any standard PROFIBUS-DP master and the system GSD file, it is possible to configure circuit monitoring, failsafe mode, HART status, and damping for the module. The software tool excom design or a PROFIBUS-DP master with V functionality enables the configuration of these parameters separately for each channel. AIH0Ex Intrinsically safe analog input module for HART-compatible transducers Zone / Division hazardous location approval with connections to approved field devices in Zone 0 / Division Connections for up to four -wire transmitters or current sources Wire-break and short-circuit monitoring Galvanic isolation between input, bus and power supply Inputs at common potential Transmission of HART signals Connections Inputs via MINI COMBICON plug-in terminals; versions available with screw, crimp or cage-clamp connections terminal configuration channel channel channel connection possibilities (selectable)? I? I channel TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

14 Analog Input Module AIH0Ex Input (HART) Type ID Number Power Supply Internal power consumption Galvanic isolation AIH0Ex M00 from central power supply via module rack < W complete isolation Inputs () analog sensors Input voltage >.0 VDC at ma (at transducer) Input current 0/ - 0 ma per input HART impedance 0 Ω Overrange > ma Short-circuit < V (in live zero mode only) Underrange -. ma Wire-break < ma (in live zero mode only) Resolution -bit Linearity tolerance < 0. % (of full scale) Temperature drift < 0 ppm/k Rise/release time < 0 ms (0-90 %) Ex Approval PTB 00 ATEX 09 X Factory Mutual Marking II () G EEx ib [ia] IIC T A Ex e m i b [ia] IIC T Max. Ex values (fieldbus circuits) EEx ia IIC/IIB Suitable for C, Div, Grps A, B, C, D No-load voltage U 0 /V oc. V Haz. Loc. (Temp Code T) with I/S Short-circuit current I 0 /I SC 9 ma entity connections to C, Div, Grps Max. power P 0 0 mw A, B, C, D; C, Div., Grps E, F, G; Typical curve trapezoidal C, Div Haz. Locations. U 0. V R 9 Ω Max. internal capacitances L i. nf Max. internal capacitances C i 0. mh Max. external capacitances L 0 /L a see diagram to right Max. external capacitances C 0 /C a see diagram to right Initial Operating Parameters Wire-break monitoring Short-circuit monitoring Substitute value programming Live zero/dead zero Software filter HART status polling Mapping of virtual HART variables 0/0 Hz suppression > 0 db LED Indications Power on/module function Input status green/red (dual color LED) () red General Data Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to 0 F) Dewing for a short period only (during system set-up) TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

15 Intrinsically Safe Remote I/O System The AIHEx is designed to connect up to four -wire transducers (passive input = sink mode/transducer active). The module is approved for Zone /Division hazardous locations with connections to approved field devices in Zone 0/Division. No additional protective measures are required for connected field devices. When connecting field devices, please observe that all inputs operate at the same potential - i.e. there is no galvanic isolation between channels. The resolution is -bits, i.e. the analog value of 0- ma is represented between 0 and. Data representation depends upon the type of control system used. HART - compatible sensors may be connected to the modules; communication takes place via the integrated HART controller. Up to HART variables (a maximum of four ) can be read via the cyclic user data transfer of PROFIBUS-DP. The bi-directional data transfer between the host system and the HART transmitter is enabled by PROFIBUS- DPV. Parameters such as wire-break and short-circuit monitoring, measuring range and HART communication parameters can be seat separately for each channel. AIHEx terminal configuration connection Intrinsically safe analog input module for HART-compatible transducers Zone / Division hazardous location approval with connections to approved field devices in Zone 0 / Division Connections for up to four -wire transducers Wire-break and short-circuit monitoring Galvanic isolation between input, bus and power supply Inputs at common potential Transmission of HART signals Connections Inputs via MINI COMBICON plug-in terminals; versions available with screw, crimp or cage-clamp connections channel channel channel channel - TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

16 Analog Input Module AIHEx Input (HART) Type AIHEx ID Number M 0 0 Power Supply Internal power consumption Galvanic isolation from central power supply via module rack < W to bus and to supply Inputs () analog sensors Input voltage >.0 VDC at ma (at transducer) Input current 0/ - 0 ma per input HART impedance 0 Ω Overrange > ma Short-circuit < V (in live zero mode only) Underrange -. ma Wire-break < ma (in live zero mode only) Resolution -bit Linearity tolerance < 0. % (of full scale) Temperature drift < 0 ppm/k Rise/release time < 0 ms (0-90 %) Ex Approval PTB 00 ATEX 09 X Factory Mutual Marking II () G EEx ib [ia] IIC T A Ex e m i b [ia] IIC T Max. Ex values (fieldbus circuits) EEx ia IIC/IIB Suitable for C, Div, Grps A, B, C, D No-load voltage U 0 /V oc. V Haz. Loc. (Temp Code T) with I/S Short-circuit current I 0 /I SC ma entity connections to C, Div, Grps Max. power P 0 9 mw A, B, C, D; C, Div., Grps E, F, G; Typical curve linear C, Div Haz. Locations. U 0. V Max. internal capacitances L i. nf Max. internal capacitances C i 0. mh Max. external capacitances L 0 /L a see table on page Max. external capacitances C 0 /C a see table on page Initial Operating Parameters Wire-break monitoring Short-circuit monitoring Substitute value programming Live zero/dead zero Software filter HART status polling Mapping of virtual HART variables 0/0 Hz suppression > 0 db LED Indications Power on/module function Input status green/red (dual color LED) () red General Data Enclosure IP 0 Operating temperature -0 to 0 C (- to 0 F) Dewing for a short period only (during system set-up) TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

17 Intrinsically Safe Remote I/O System Analog Input Module AIHEx Input (HART) Max. external inductances L 0 Max. external capacitances C 0 For active intrinsically safe transducers with linear output curve (li = 00 ma) Max. Values EEx ia EEx ib IIC EEx ia EEx ib IIB U i L 0 C 0 L 0 C 0 V.mH. µf 9. mh µf V.mH. µf 9. mh µf 0 V. mh ηf 9. mh. µf V. mh ηf 9. mh. µf. V. mh ηf 9. mh 90 ηf 0 V. mh ηf 9. mh ηf V. mh ηf 9. mh 9 ηf V.0 mh ηf 9.0 mh ηf 0 V.0 mh ηf 9.0 mh ηf For active intrinsically safe transducers with trapezoidal output Max. Values EEx ia EEx ib IIC EEx ia EEx ib IIB U i I i L 0 C 0 L 0 C 0. V 9 ma 0. mh 0 ηf mh 0 ηf For active intrinsically safe transducers with rectangular or trapezoidal output curve Max. Values EEx ia EEx ib IIC EEx ia EEx ib IIB U i I i L 0 C 0 L 0 C 0 V 00 ma.99 mh 00 ηf.9 mh µf V 00 ma.99 mh 00 ηf.9 mh. µf 0V 90mA.99mH 00 ηf.9 mh µf V ma 0.99mH 00 ηf.9 mh 00 ηf. V 9 ma 0.99 mh 00 ηf.9 mh 00 ηf 0V ma 0.99mH 0 ηf.9 mh 00 ηf. V 9 ma mh 00 ηf V 0 ma mh 00 ηf V ma mh 00 ηf 0 V 0 mh mh 0 ηf TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

18 Notes: TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: ()

19 Intrinsically Safe Remote I/O System The TI0Ex is a four-channel analog input module designed for connection to -, -, and -wire RTDs or thermocouples. PT00, PT000, and NI00 RTDs are supported, as well as types B, E, J, K, L, N, R, S, and T thermocouples. The module is approved for Zone / Division hazardous locations with connections to approved field devices or simple apparatus in Zone 0 / Division. No additional protective measures are required for connected field devices. Input compensation for -wire RTDs occurs on-line during initial operating parameter assignment. The module short-circuits the measuring circuit as well as the two additional terminals and automatically compensates for lead resistance. When using thermocouple inputs, PT00 resistors may be used across the two unused terminals of each channel for cold junction compensation. The resolution is bits, i.e. the analog value of 0- ma is represented as a number between 0 and. Data representation depends upon the type of control system used. Using any standard PROFIBUS-DP master and the system GSD file, it is possible to configure circuit monitoring, failsafe mode, damping, and sensor type for the module. The software tool excom design or a PROFIBUS-DP master with V functionality enables the configuration of these parameters separately for each channel. TI0Ex Intrinsically safe analog input module for RTDs such as PT00, PT000 and Ni00 as well as B, E, J, K, L, N, R, S and T style thermocouples Zone /Division hazardous location approval with connections to approved field devices in Zone 0/ Division Connections for up to four -, - or -wire detectors Wire-break and short-circuit monitoring Galvanic isolation between input, bus and power supply Galvanic isolation between channels Connections Inputs via MINI COMBICON plug-in terminals; versions available with screw, crimp or cage-clamp connections terminal configuration channel channel channel channel connection possibilities (selectable) -wire RTH-LRTD -wire RTH-LRTD -wire RTH-LRTD balancing bridge PT00-VG resistor TC 0 TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

20 Thermocouple Input Module TI0Ex Input Type ID Number Power Supply Internal power consumption Galvanic isolation TI0Ex M000 from central power supply via module rack W complete isolation Inputs () -/-/-wire resistance temperature detectors (RTDs) or thermocouples Input (RTD) Line resistance (-wire) < 0 Ω Line resistance (-wire) < 0 Ω Line resistance (-wire) < Ω Resolution -bit Short-circuit threshold < Ω Wire-break threshold > 00 Ω Input (thermocouple) Wire-break threshold < 00 ma / > 0 mv Calibration accuracy < 0. k; < 0 m Ω ; < 0.0 mv Resolution -bit Linearity tolerance < 0.0 % (of full scale) Temperature drift < 0 ppm/k Rise/release time < 00 ms (0-90 %) Ex Approval PTB 00 ATEX Factory Mutual Marking II () G EEx ib[ia] IIC T A Ex e m i b [ia] IIC T Max. Ex values (field circuits) EEx ia IIC/IIB Suitable for C, Div, Grps A, B, C, D Haz. Loc. (Temp Code T) entity connections to C, Div, Grps A, B, C, D; C Div, Grps E, F, G; C, Div Haz Loc. connection to passive field device connection to passive field device (e.g. resistance detectors) (e.g. thermo-elements) No-load voltage U 0 /V oc. V. V Short-circuit current I 0 /I SC ma 0 ma Max. power P 0 mw 0 mw Typical curve linear Max. internal inductances L i negligible negligible Max. internal capacitances C i 0 nf negligible Max. external inductances L 0 /L a see diagram on right Max external capacitances C 0 /C a see diagram on right Initial Operating Parameters Wire-break monitoring Short-circuit monitoring Substitute value programming Software filter 0/0 Hz suppression > 0 db LED Indications Power on/module function Input status green/red (dual color LED) () red General Data Hazardous location approval EEx ib [ia] IIC T (PTB 00 ATEX ) Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to F) Dewing for a short period only (during system set-up) TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

21 Intrinsically Safe Remote I/O System The DO0Ex is a four-channel discrete output module designed for connection to intrinsically safe actuators (such as solenoids valves) and annunciators. The module is approved for Zone / Division hazardous locations with connections to approved field devices or simple apparatus in Zone 0 / Division. No additional protective measures are required for connected field devices. The output load curve for each of the four outputs is shown on the table on the right. For example, the following output variations are possible: - V / ma - V / ma - V / ma - V / ma Using any standard PROFIBUS-DP master and the system GSD file, it is possible to configure circuit monitoring, failsafe mode, and polarity for the module. The software tool excom design or a PROFIBUS-DP master with V functionality enables the configuration of these parameters separately for each channel. DO0Ex Discrete output module for intrinsically safe actuators Zone / Division hazardous location approval with connections to approved field devices in Zone 0/ Division Connections for up to four valves or indicators Wire-break and short-circuit monitoring Galvanic isolation between output, bus and power supply Galvanic isolation between channels Connections Outputs via MINI COMBICON plug-in terminals; versions available with screw, crimp or cage-clamp connections terminal configuration channel channel channel connection possibilities (selectable) U 0 V U 0 9 V U 0 9 V channel U 0 V TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

22 Discrete Output Module DO0Ex Output, 0 to VDC Type ID Number Power Supply Internal power consumption DO0Ex M00 from central power supply via module rack <. W Outputs () actuators () actuators Output voltage VDC VDC Nominal current V / ma; V / ma V / ma; V / ma Internal resistance 00 Ω 00 Ω Switching frequency < 00 Hz < 00 Hz Short-circuit threshold < V < V Wire-break threshold < ma < ma Ex Approval PTB 0 ATEX 0 Factory Mutual Marking II () G EEx ib [ia] IIC T and A Ex e m i b [ia] IIC T Maximum Ex Values (field circuits) EEx ia IIC/IIB Suitable for C, Div, Grps A, B, C, D Haz Loc. (Temp Code T) with I/S entity connections to C, Div, Grps A, B, C, D; C, Div, Grps E, F, G;C Div Haz Loc. Short-circuit curent I 0 /I SC 00 ma 00 ma No-load voltage U 0 / V OC.9 V Max. power P 0 mw mw Typical curve trapezoidal linear Max. internal inductances L i nf nf Max. internal capacitances C i negligible negligible Max. external inductances L 0 /L a see diagram see diagram Max. external capacitances C a see diagram see diagram Initial Operating Parameters Wire-break monitoring Short-circuit monitoring Substitute value programming LED Indications Power on/module function Output status green/red (dual color LED) () yellow/red (dual color LED) General Data Hazardous location approval EEx ib [ia] IIC T (PTB 00 ATEX 0) Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to 0 F) Dewing for a short period only (during system set-up) Load curve V 0 0 Uo < V Uo <,9 V ma TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

23 Intrinsically Safe Remote I/O System The AO0Ex is a four-channel analog output module designed for connection to intrinsically safe analog actuators. HART-compatible actuators may be connected and communicated with via an approved HART modem on the field side of the system. However, HART communications will not pass through the AO0Ex. The module is approved for Zone hazardous locations with connections to approved field devices in Zone 0. No additional protective measures are required for connected field devices. The resolution is bits, i.e. the analog value of 0- ma is represented as a number between 0 and 9. Data representation depends upon the type of control system used. Using any standard PROFIBUS-DP master and the system GSD file, it is possible to configure circuit monitoring, failsafe mode, and output range for the module. The software tool excom design or a PROFIBUS-DP master with V functionality enables the configuration of these parameters separately for each channel. AO0Ex Intrinsically safe analog output module for 0/ to 0 ma actuators Zone /Division hazardous location approval with connections to approved field devices in Zone 0/ Division Connections for up to four actuators Wire-break and short-circuit monitoring Galvanic isolation between output, bus and power supply Galvanic isolation between channels Connections Outputs via MINI COMBICON plug-in terminals; versions available with screw,crimp or cage-clamp connections TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

24 Analog Output Module AO0Ex Output Type ID Number Power Supply Internal power consumption Galvanic isolation AO0Ex M00 from central power supply via module rack <. W complete isolation Outputs () analog actuators Output voltage < VDC Output current 0/ - 0 ma per output External load < 00 Ω HART impedance > 0 Ω Short-circuit threshold < 00 Ω (in live zero mode only) Wire-break threshold < ma (in live zero mode only) Resolution -bit Linearity tolerance < 0. % of final value Temperature drift < 0 ppm/k Rise/release time < 0 ms (0-90 %) Ex Approval PTB 00 ATEX 9 Factory Mutual Marking II () G EEx ib [ia] IIC T and A Ex e m i b [ia] IIC T Maximum Ex Values (field circuits) EEx ia IIC/IIB Suitable for C, Div, Grps A, B, C, D Haz Loc. (Temp Code T) with I/S entity connections to C, Div, Grps A, B, C, D; C, Div, Grps E, F, G;C Div Haz Loc. No-load voltage U 0 / V OC.9 V Short-circuit current I 0 / I SC 0 ma Max. power P 0 0 mw Typical curve trapezoidal Max. internal inductances L i negligible Max. internal capacitances C i nf Max. external inductances L 0 /L a see diagram Max. external capacitances C a /C a see diagram Initial Operating Parameters Wire-break monitoring Short-circuit monitoring Substitute value programming Live zero/dead zero LED Indications Power on/module function Output status green/red (dual color LED) () red General Data Hazardous location approval EEx ib [ia] IIC T (PTB 00 ATEX 9) Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to F) Dewing for a short period only (during system set-up) TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

25 Intrinsically Safe Remote I/O System MT MT9 MT Backplane that supports up to // I/O modules, // gateways and // power supply units Protection type EEx m, EEx e, EEx i Up to discrete or analog inputs/outputs Connections for two redundant gateways (MT only) Connections for two redundant power supply units (MT only) Connections Inputs and outputs via plug-in MINI COMBICON terminals; versions available with screw, crimp or cageclamp connections (consult factory) Bus connection via miniature 9-pole D-SUB connector Power supply via EEx e screw terminals The MT backplane supports two gateways, two power supplies and sixteen I/O modules. Up to discrete inputs/outputs or analog inputs/outputs may be connected in any combination. Modules may be exchanged during system operation without interrupting data communication (gateways and power supplies only in case of redundant system design). The backplane features a combined protection type of EEx m, EEx e and EEx i and is approved for installation in Zone / Division locations. The backplane is made of extruded aluminium sections for increased stability and ensured shielding. It is suited for wall mounting and 9 rail mounting. Modules receive power via the backplane. Supply energy is limited to levels suitable for Zone / Division (protection type EEx [ib] IIC). Therefore, modules can be exchanged during system operation. Other backplanes such as the MT9 and MT are available. The MT9 version supports one power supply, one gateway and up to eight I/O modules. The MT supports one power supply, one gateway and up to four I/O modules. Unlike the MT, the MT and MT9 are not designed to configure a redundant system with double gateways or power supplies. TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

26 Backplane MT/MT9/MT Support // Modules Type MT MT9 MT ID Number M90090 M900 M9009 Power Supply External - VDC - VDC - VDC Power 0 W/00 VA 0 W/0 VA W/0 VA Connections Bus (D-SUB, miniature 9-pole version) Supply (EEx e dual screw terminals) Field devices x terminals per module in screw, crimp or cage-clamp styles (total ) Slots Power supply Gateway I/O module Adjustments Bus address () decimal-coded rotary switches (0 to ) Dimensions (w x h x d) [mm] 9. x 0 x 0. x 0 x 0. x 0 x 0 (without mounting brackets) General Data Hazardous location approvals (PTB 00 ATEX 9U) EEx e m [ib] IIC T - Bus connection EEx ib IIC T - Power supply EEx e - I/O field device connections EEx ia IIC T Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to 0 F) Dewing for a short period only (during system set-up) TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

27 Intrinsically Safe Remote I/O System The PSDEx power supply provides power to two gateways and a maximum of sixteen I/O modules. This equates to discrete inputs/outputs or analog inputs/outputs in any combination. The power supply features a combined protection type: EEx m, EEx e and EEx i and can be installed in Division, Zone or Zone hazardous locations. It is integrated into a protective aluminum housing and is fully encapsulated, eliminating the need for additional explosion protection measures. If the system is configured with redundant power supplies one of which malfunctions, it may be replaced without interrupting system operation. The PSDEx accepts - VDC. Each supply is connected to the backplane via Ex e terminals, which may not be accessed live. They are located under a protective cap and may only be accessed after suspending the supply voltage. Redundancy: It is possible to use two power supplies. If one of the devices or the incoming line fails, the second supply takes over as system supply. The supplies do not need to be the same. PSDEx AC and DC power supply units to supply a fully configured backplane Redundant design with MT backplane Protection type EEx m, EEx e, EEx i Supply of up to discrete or analog inputs/outputs Aluminum housing Complete encapsulation Connection Via backplane TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

28 Intrinsically Safe Power Supply PSDEx Type ID Number PSDEx M Power Supply External - VDC (ripple W pp < 0 %) Power consumption W Power output 0 W Galvanic isolation V peak value per EN 000 LED Indications Power on/module function Supply green green General Data Hazardous location approvals EEx e m ib IIC T (PTB 00 ATEX 9) Enclosure IEC IP 0 Operating temperature -0 to 0 C (- to 0 F) Dewing for a short period only (during system set-up) Dimensions (w x h x d) mm x mm x 0 mm Mounting flange, () M screws TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: ()

29 Intrinsically Safe Remote I/O System TURCK Inc. sells its products through Authorized Distributors. These distributors provide our customers with technical support, service and local stock. TURCK distributors are located nationwide - including all major metropolitan marketing areas. For Application Assistance or for the location of your nearest TURCK distributor, call: -00-TURCK-IS (-00--) Specifications in this manual are subject to change without notice. TURCK also reserves the right to make modifications and makes no guarantee of the accuracy of the information contained herein. Literature and Media questions or concerns? Contact Marketing Services at TURCK USA: media@turck.com 0 TURCK Inc. 000 Campus Drive Minneapolis, MN Application Support: -00-TURCK-IS Fax: () -00

Sense it! Connect it! Bus it! Solve it! REMOTE I/O excom

Sense it! Connect it! Bus it! Solve it! REMOTE I/O excom Sense it! Connect it! Bus it! Solve it! REMOTE I/O excom Remote I/O System excom Intrinsically safe remote I/O system for use in zone 1 and zone 2 Redundant power supplies and gateways Intrinsically safe

More information

REMOTE I/O excom F 395/08

REMOTE I/O excom F 395/08 REMOTE I/O excom F 9/0 Intrinsically Safe Remote I/O System Intrinsically safe remote I/O system for use in zone and zone Redundant power supplies and gateways Intrinsically safe connection to PROFIBUS-DP

More information

excom Remote-I/O system Short Description

excom Remote-I/O system Short Description Short Description 178 Hans Turck GmbH & Co. KG Tel. 49 208 49 52-0 Fax 49 208 49 52-264 Short Description excom Remote-I/ excom Remote-I/O system excom Remote-I/O for non-ex and Ex areas excom is a remote

More information

excom FIELDBUS COMPONENTS F 395/02

excom FIELDBUS COMPONENTS F 395/02 FIELDBUS COMPONENTS excom Your fieldbus connection F 9/0 Hans Turck GmbH & Co.KG D Mülheim an der Ruhr Tel. 00/9-0 Fax 00/9- E-Mail: turckmh@mail.turck-globe.de www.turck.com /090 Intrinsically Safe Remote

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2 Technical Data Communication Adapter Catalog Number 1719-AENTR I/O Module Catalog Numbers 1719-IJ, 1719-IBN8B, 1719-IF4HB, 1719-IR4B, 1719-IT4B, 1719-OB2, 1719-OB2L, 1719-CF4H Power Supply Catalog Number

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing system in total PLC PC Not hazardous area PROFIBUS DP Associated Apparatus Class I, DIV 2, GP A...D Class I, ZN 1, IIC T4 PROFIBUS-DP Ex i Terminating resistor Class

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

I/A Series HARDWARE Product Specifications

I/A Series HARDWARE Product Specifications I/A Series HARDWARE Product Specifications PSS 21H-2Y6 B4 Intrinsically Safe I/O Subsystem ISCM Base Unit for LB (Zone 2) Applications ISCM Base, Extension and Redundancy Units for FB (Zone 1) Applications

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017 November 2017 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704,

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

M-series Intrinsically Safe I/O

M-series Intrinsically Safe I/O DeltaV Distributed Control System Product Data Sheet M-series Intrinsically Safe I/O Features full system modularity Reduces system footprint Decreases installation time and expense Plug-and-play installation

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018 September 2018 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Analog Input Module RSTI-EP Slice I/O Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664,

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Temperature Converters

Temperature Converters TURCK Interface Technology Temperature measurement is a very common application, even in hazardous areas. The IM34 temperature converting device provides advanced diagnostics, versatility and convenience

More information

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.

More information

S900 Remote I/O System Intrinsic safety in the field ABB

S900 Remote I/O System Intrinsic safety in the field ABB S900 Remote I/O System Intrinsic safety in the field ABB 2 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 Remote I/O System 01 Example of Field housing FH660S in stainless steel with complete

More information

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P Type designation Ident-No. 6811073 Nominal system voltage System power supply Admissible range V+ Nominal current V+ Max. current V+ Electrical isolation Via DeviceNet 18 30VDC 430 ma 4 A The 8XSG I/O

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Operating instructions

Operating instructions Operating instructions Digital Input Output Module > Contents 1 Contents 1 Contents...2 2 General information...3 2.1 Manufacturer...3 2.2 Information regarding the operating instructions...3 2.3 Conformity

More information

BL compact fieldbus station for DeviceNet 4 Analog Outputs for Voltage BLCDN-4M12S-4AO-V

BL compact fieldbus station for DeviceNet 4 Analog Outputs for Voltage BLCDN-4M12S-4AO-V On-machine Compact fieldbus I/O block DeviceNet slave 125 / 250 / 500 kbps Two 5-pole M12 connectors for fieldbus connection 2 rotary switches for node address IP67, IP69K M12 I/O connectors LEDs indicating

More information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current

More information

Your Global Automation Partner. IM Interface Technology in Modular Housings

Your Global Automation Partner. IM Interface Technology in Modular Housings Your Global Automation Partner IM Interface Technology in Modular Housings Interface Technology in Modular Housings IM Series Functions and selection guide 10 11 12 7 8 9 16 17 18 19 20 11 12 13 14 15

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256

LB Remote I/O. CEAG Sicherheitstechnik GmbH 256 LB Remote I/O Description LB Remote I/O modules are used as signal conditioning units between field devices and control systems. They plug into a backplane system which is mounted on a standard DIN rail.

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

MACX MCR-EX-SD LP(-SP)

MACX MCR-EX-SD LP(-SP) Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)

More information

DISOMAT T Weigh Transmitter

DISOMAT T Weigh Transmitter DISOMAT T Weigh Transmitter Digital weigh transmitter Single-ingredient feed control System-compatible through serial interface, analog output and binary inputs/outputs Suitable for multi-scale systems

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Sense it! Connect it! Bus it! Solve it! INTERFACE TECHNOLOGY

Sense it! Connect it! Bus it! Solve it! INTERFACE TECHNOLOGY Sense it! Connect it! Bus it! Solve it! INTERFACE TECHNOLOGY Interface technology Interface gy Interface technology ac e gy more@turck.com www.turck.com Interface technology Edition I/0 The company The

More information

Your Global Automation Partner. excom I/O System

Your Global Automation Partner. excom I/O System Your Global Automation Partner excom I/O System excom I/O System for Ex and Non-Ex Areas Turck s excom I/O family offers a universal I/O system that can be installed in zone 1/21 and in zone 2/22 or in

More information

BL compact fieldbus station for DeviceNet 2 Analog Inputs for Current or Voltage and 2 Analog Outputs for Voltage BLCDN-4M12S-2AI2AO-VI

BL compact fieldbus station for DeviceNet 2 Analog Inputs for Current or Voltage and 2 Analog Outputs for Voltage BLCDN-4M12S-2AI2AO-VI On-machine Compact fieldbus I/O block DeviceNet slave 125 / 250 / 500 kbps Two 5-pole M12 connectors for fieldbus connection 2 rotary switches for node address IP67, IP69K M12 I/O connectors LEDs indicating

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-8M12LT-8XSG-PD-8XSG-PD On-machine Compact fieldbus I/O block DeviceNet slave 125 / 250 / 500 kbps Two 5-pole M12 connectors for fieldbus connection 2 rotary switches for node address IP67, IP69K M12 I/O connectors LEDs indicating

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design

More information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................

More information

S-series Electronic Marshalling

S-series Electronic Marshalling DeltaV Distributed Control System Product Data Sheet July 2017 S-series Electronic Marshalling I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture

More information

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications. EN ADAMCZEWSKI Elektronische Messtechnik GmbH Felix-Wankel-Str. 13 / 74374 Zaberfeld Tel. +49 (0)7046-875 Fax +49 (0)7046-7678 vertrieb@ad-messtechnik.de Operating Instructions Supply Isolation Amplifier

More information

Rotary Measurement Technology Absolute Encoders, Multiturn

Rotary Measurement Technology Absolute Encoders, Multiturn -40 to 80 C IP Mechanical drive Safety-LockTM High rotational speed Temperature High IP High shaft load capacity Shock/ vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection

More information

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Interface technology. Interface technolog. Interface technology INTERFACE TECHNOLOGY. Sense it! Connect it! Bus it! Solve it!

Interface technology. Interface technolog. Interface technology INTERFACE TECHNOLOGY. Sense it! Connect it! Bus it! Solve it! Interface technology Interface technolog Interface technology INTERFACE TECHNOLOGY Sense it! Connect it! Bus it! Solve it! Hans Turck GmbH & Co. KG Tel. +9 (0) 9-0 Fax +9 (0) 9 - more@turck.com www.turck.com

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

DeltaV SIS Conditioning Components

DeltaV SIS Conditioning Components DeltaV SIS Process Safety System DeltaV SIS Conditioning Components The DeltaV SIS conditioning components allow you to use the DeltaV SIS system with a variety of different field signal requirements.

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

DeltaV SIS TMConditioning Components

DeltaV SIS TMConditioning Components February 2016 Page 1 DeltaV SIS TMConditioning Components The DeltaV SIS conditioning components allow you to use the DeltaV SIS system with a variety of different field signal requirements. Enables diagnostics

More information

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design

More information

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD

BL compact fieldbus station for DeviceNet 4 Analog Inputs for Current or Voltage and 8 Configurable Digital PNP Channels BLCDN-8M12L-4AI-VI-8XSG-PD On-machine Compact fieldbus I/O block DeviceNet slave 125 / 250 / 500 kbps Two 5-pole M12 connectors for fieldbus connection 2 rotary switches for node address IP67, IP69K M12 I/O connectors LEDs indicating

More information

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas

WAGO-I/O-SYSTEM. Fieldbus Technology. for Use in Hazardous Areas WAGO-I/O-SYSTEM Fieldbus Technology for Use in Hazardous Areas For Use in Hazardous Areas The WAGO-I/O-SYSTEM 0 is a modular, fi eldbus-independent I/O system for decentralized automation. This system,

More information

Analog Output Isolators

Analog Output Isolators TURCK Interface Technology Analog output isolators are for use with conventional 4/20 ma or HART smart "IS" devices are available in 1 and 2 channel versions. These devices are designed to provide a convenient

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Process Current Input 7B32 FEATURES Interfaces, amplifies and filters a process-current input. Module provides a precision output of either +1 V to +5 V or 0 V to +10 V, linear with temperature.

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001 PROCESS AUTOMATION MANUAL Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The general terms of delivery

More information

PA ROUTERS. The following criteria can be applied when choosing the network transition:

PA ROUTERS. The following criteria can be applied when choosing the network transition: PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied

More information

DeltaV Electronic Marshalling

DeltaV Electronic Marshalling DeltaV Distributed Control System Product Data Sheet DeltaV Electronic Marshalling I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture Field-mounted

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics

More information

MTL8000-2/x Series Modular I/O

MTL8000-2/x Series Modular I/O -2/x Series Modular Overview Modules Modules - Overview - 2/2 components Use this option for general purpose or nonhazardous applications, or where the equipment and/or field wiring has to be mounted in

More information

RSTI-EP Slice I/O. Digital Output Module

RSTI-EP Slice I/O. Digital Output Module GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status

More information

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated, Voltage or Current Input 7B30 FEATURES Interfaces, amplifies and filters unipolar and bipolar millivolt and voltage inputs. Provides a protected precision output of either +1 V to +5 V or 0 V

More information

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design

More information

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver February 2016 Page 1 DeltaV SIS TM Logic Solver The DeltaV SIS platform is the world s smart SIS system to use the power of predictive intelligence for increasing the availability of the entire safety

More information