Model CDS 1000 Installation & Operation

Size: px
Start display at page:

Download "Model CDS 1000 Installation & Operation"

Transcription

1 Model CDS 1000 Installation & Operation SUBJECT TO CHANGE Web Site: Turbines, Inc.-All Rights Reserved CDS 1000-QRG.xls

2 Table of Contents Section Pg Warranty 3 Installation 4 Operation 5 Programming 6-9 Specifications 10 Troubleshooting 11 Illustrations Turbines, Inc.-All Rights Reserved CDS 1000-QRG.xls

3 Limited Warranty Turbines Inc. of Altus Oklahoma provides the following statement of warranty and is subject to the following terms and conditions. No other warranty or guaranty express or implied shall be operative or binding upon the company at any time, or under any circumstances. Turbines Inc. shall warranty that the product(s) described hereunder shall be free from material defect, shall be of the first quality, manufactured in accordance with the standards and practices of the highest workmanship and materials, for a period not to exceed 12 months (one year) following date of purchase by the end user, subject to limitations as described: Article 1: The warranty shall be limited to equipment for which the company has been fully paid. In the event of nonpayment, the company reserves the right to void any warranties that may otherwise apply. Article 2: This warranty shall specifically exclude any deterioration or effects resulting from the normal wear and tear of the equipment or components thereof. Article 3: This warranty shall specifically exclude damage that has resulted from improper installation of, improper maintenance of, unauthorized change or modification to, improper operation of, and/or misuse or abuse of the subject equipment. Article 4: At the manufacturer s sole option, any equipment covered hereunder shall be either repaired or replaced at the manufacturer s expense during the term of the warranty, subject to said equipment being shipped prepaid to the manufacturer s principle place of business, Turbines Inc., Highway 283 North, Altus, Oklahoma, USA o equipment shall be accepted unless first authorized in writing by the manufacturer. Non-warranty damage shall be repaired solely at the customer s expense. Article 5: In no event shall the manufacturer s liability exceed the original cost of said equipment at the time of original purchase. The manufacturer shall, under no circumstances and/or at any time, assume any liability for merchantability, or any damages or contingent liabilities that may arise from the purchase or use of said equipment by any parties. Article 6: This warranty is non-transferable and shall apply exclusively to the original end purchaser or end user of said equipment. Article 7: The expected useful service life of said equipment shall vary dependent, among other factors, upon proper use, handling and maintenance Turbines, Inc.-All Rights Reserved Page 3 CDS 1000-QRG.xls

4 Turbines, Inc. PO BOX Altus, OK U.S.A. Call us Toll Free: or (508) * Fax: (580) Web Site: * Karen@turbinesincorporated.com shane@turbinesincoporated.com, kevin@turbinesincorporated.com, terrie.n@turbinesincorporated.com Complete Delivery System Thank You for your purchase. For best equipment performance, please following these simple installation/operation/programming instructions. Installation 1. Ensure that you have removed all equipment from the shipping box. 2. Verify you received everything listed on the packing list. 3. Mount the CDS 1000 at a height & angle ensuring ease of accessibility and visibility. 4. Apply a thin layer of Oxygen safe lubricant to the knob threads to avoid corrosion. 8. Allow slack in each cable to permit the CDS 1000 to rotate forward for rear panel access. 7. Install cables and connect to rear panel. Ensure that each connector is "handtight". 6. Apply a thin layer of Oxygen safe lubricant to the connector threads to avoid corrosion. 5. Avoid installing the unit under piping that defrosts or near pumps that spray liquid. 9. Terminate the "POWER" cable at the battery or most direct input source to avoid interference. 10. NOTE: The "POWER" is polarity insensitive. 11. We recommend that "POWER" be direct to source. 12. Install the 1000ohm probe. (downstream of the turbine) and connect the temperature cable. 16. Your equipment is now ready for use. Proceed to "Operation" Press CDS 1000 ON/OFF Button and observe LED lights are on or flashing. 14. Install the Turbine Meter and connect the signal cable or connect signal cable to your existing meter. 13. Install the piping. (If you did not purchase piping, skip to next) For detailed instructions for assembly and disassembly of your Turbine Meter, download manual from our website: Turbines, Inc.-All Rights Reserved Page 4 CDS 1000-QRG.xls

5 Operation Temperature Indicator Rate Indicator Observe "BLUE" LED illuminated. Indicates unit is powered "ON" Observe "WHT" LED illuminated or flashing. Indicates unit is receiving signal from turbine meter Displays "Grand total" (non-resettable) Displays "Batch total" (resettable) Observe "RED" LED "OFF". If Illuminated, Press "D" for alarm list. Press to see unit DETAILS list and perform Battery TEST Press to enter "PROVE" mode. Password required. To exit "PROVE", power unit "OFF" Press to RESET totalizer to ZERO Press to PRINT (only if printer is used) Press to see list of "Current Alarms" Indicates "Pump Cooldown Timer". Only appears during countdown and if enabled. System power (ON/OFF) Indicates "System Maintenance alarm Press D for alarm list. To Pressure device (4-20mA) To 1000 ohm RTD To pump control box To Pickup coil (turbine meter) To RS232 To Battery Consult Factory for WIRING CONFIGURATIONS NiMH Battery Mounting Bracket 2009-Turbines, Inc.-All Rights Reserved Page 5 CDS 1000-QRG.xls

6 Programming Your Model CDS 1000 is factory set. You should only use this programming guide to change your parameters or turn on additional features. For problems, call Power unit "OFF". NOTE: Press "ESC" to exit any screen, press "ENT" to enter, "CLR" to delete N/A indicates "PRIVILEGED" access ONLY! Press and hold "ESC". While holding, press and release "ON/OFF" for about 1 second to access the Initialization Options Menu 1] Set Clock & Language 1] Set clock 1] Set time Hours (0-23)? Type value, press "ENT" Minutes (0-59)? Type value, Date (1-31)? Type value, press "ENT" Month (1-12)? Type value, press "ENT" Year (0-99)? Type value, press "ENT" 2] DST start 3] DST end Sunday of mth (0-5)? Sunday of mth (0-5)? Month (1-12)? Month (1-12)? 2] Select language Press English 2 - Francais 2] Adjustment Mode (enter passcode) (default 1000) 1] Calibration 2] Configuration 1] Avg. Kfactor 2] Linearizer Table 3] Linearizer 1] Compensation 2] Product 3] Units of measure 4] Digits right of Decimal Enter Setting Press "0" OFF, "1" ON Press 1-8 1] Ratemeter 2] Totalizer 3] Temperature Press "ENT" (Not normally used, to use reference full technical manual for instructions. Linearizer (option 3) must be "ON") Press "0" OFF, "1" ON (Must be "ON") Press 1-8 Press = LOX 2 = LIN 3 = LAR 4 = LCO2 5 = LN2O 6 = CC02 7 = MAPP 8 = LPG 1 = Kelvin 2 = Centigrade 3 = Fahrenheit Press 0-2 5] Dual Coil Press "0" NO, "1" YES 6] Printer Checking Press "0" NO, "1" YES (Must be "ON" for Turbines Inc. printer) 1 = Gal (Gallons) 2 = Liter (Liters) 3 = Lbs (Pounds) 4 = Lbs x 10 5 = kg (Kilograms) 6 = Scf (Standard cubic feet) 7 = Scf x = m3 (Cubic meters) Next Page 2009-Turbines, Inc.-All Rights Reserved Page 6 CDS 1000-QRG.xls

7 Options 4-9 Factory Use Only 3] Change System Settings (enter password) 1] Flowmeter size 2] Alarm and timer settings 3] Serial numbers Press 1-9 (default 1000) (to change printer settings, enter "77468") 1]Totalize during alarm 2] Pump cooldown timer 3] Pump cooldown delay 4] Intermittent temp. tolerance 5] Pump ON during alarm 6] Count while temp fail 1 = 1/2" 2 = 5/8" 3 = 3/4" 4 = 1.0" 5 = 1 1/4" 6 = 1 1/2" 7 = 2.0" 8 = 3.0" 9 = 4.0" Press "0" NO, "1" YES Press "0" OFF, "1" ON Enter Setting in seconds, press "ENT" Enter Setting in seconds, press "ENT" Press "0" NO, "1" YES Press "0" OFF, "1" ON (Max 9999) (Max 9999) 1]Flowmeter 2] Plant 3] Trailer 4] N/A 5] N/A 6] BT Authentication # (1234 for standard printer) (Max 9999) 4] User Passcode 5] Maintenance Factory set to "1000". To change, type new value (up to 16 digits), press "ENT" 1] System maintenance due 2] System maintenance just performed 3] Turbines hrs until maintenance 4] Turbine maintenance just performed 5] Pump has until maintenance 6] Pump maintenance just performed 6] "N/A" or "Printer Type" when printer password is used. All other menu options display "N/A" until unit resets except 0] Goto page 2 (select for ticket set up). 1] Disabled 2] N/A 3] N/A 4] Predefined with Titles 5] Turbines w/o titles Enter setting "DDMMYY" Press "1" YES, "0" NO Enter Setting in hours, press "ENT" Press "1" YES, "0" NO Enter Setting in hours, press "ENT" Press "1" YES, "0" NO Select to disable "PRINT" Displays titles. Example- Total: 0000 Doesn't display titles Example (Max 9999) (Max 9999) Next Page 6] & 7] are blank 2009-Turbines, Inc.-All Rights Reserved Page 7 CDS 1000-QRG.xls

8 SKIP TO NEXT PAGE IF YOU ARE NOT PERFORMING TICKET SETUP 3] Change System Settings continued when password is initialized 0] Goto page 2 1] N/A 2] Print format 1/2 3] Print format 2/2 4] Print comm 1] Baud rate 2] EOL character Use Bluetooth 1] Product 2] Temp. 3] Temp. UOM 4] Date 5] Time 6] TCF 7] Start 8] Stop 9] Total 1] Deliv UOM 2] Deliv info 3] Copy # 4] Meter # 5] Trailer # 6] Serial # 7] Delivery # 8] Title 9] Lines/page Press 1-4 Press 1-4 Press "1" YES, "0" NO 1 = = = = 9600 Select and enter the value for the position/order to display on the ticket: Example "01.01" is the first position An unused value will print blank Select and enter the value for the position/order to display on the ticket: Example "01.01" is the first position An unused value will print blank 1 = none 2 = CR (center) 3 = LF (left) 4 = CR+LF 5] Print timeout Enter Setting in seconds, press "ENT" 6] Spare 7] Spare 8] N/A 9] N/A 0] Return to page 1 Press "ESC" to EXIT. System will display "R", meaning it is resetting. Pressing and holding "ESC" immediately following pressing "ESC" to EXIT will return the system back to the main menu. If you do not return back to the main menu, power unit off and start over Turbines, Inc.-All Rights Reserved Page 8 CDS 1000-QRG.xls

9 3] Change System Settings continued... 7] System Alarm Log Definitions Low Power Low input power below 8.75v Low Batt Backup battery voltage below 8.5v Coil Short P/U Coil resistance below 250 ohms Coil Open P/U Coil resistance above 2500 ohms RTD Short Probe resistance below 100 ohms RTD Open Probe resistance above 2000 ohms Tloop Short Temperature loop current above 35mA Tloop Open Temperature loop current below 4mA Ploop Short Pressure loop current above 35mA Ploop Open Pressure loop current below 4mA (Press any key to continue) Example 8] System Activity 9] N/A Turbine hrs: 10.9 Pump hrs: 15 System hours: 25.6 Power cycles: 55 Backup Batt sec: 125 Last System PM: 1-Apr-10 Last Turbine PM: Last Pump PM: (Press any key to continue) Options 4-9 Factory Use Only 0] Goto page 2 1] View audit trail 1] Calibration event log 2] Configuration event log 3] Event counters Example Apr-10 14:29 -Lin. table Apr-10 10:51 -Lin. Table -Factor = Apr-10 15:54 -Lin. table Apr-10 11:54 -Lin. table -Factor = Mar-10 13:11 -Lin. table (Press any key to continue) Example Apr-10 11:00 -DP = Apr-10 10:51 -Product = LOX -DP = Apr-10 15:54 -Product = LIN Apr-10 11:54 -Product = LAR 2] N/A 3] N/A 4] N/A 5] N/A 4] Print Example Calibration Counter - 5 Configuration counter - 4 (Press any key to continue) (Press any key to continue) 6] Spare 7] Spare 8] N/A 9] N/A 0] Return to page Turbines, Inc.-All Rights Reserved Page 9 CDS 1000-QRG.xls

10 HARDWARE Specifications Amplifier Input Frequency range Hz Sensitivity Impedance Noise immunity Pickup coil failure detection 15mv 10 Hz (min) 100mv 500 Hz (min) 400mv 2.5 KHz (min) Approx. 10k ohms High frequency roll off, 2.5 KHz 500µA excitation to read coil resistance via internal circuit ohms full scale. Sensor Inputs Temperature probe 1000 ohm platinum RTD probe 8mA constant current sensor excitation, 200 ohms full scale ratio metric and chopper stabilized to avoid drift Power Sensors Continuous monitoring of main power, backup battery & sensors. Outputs Pump Control (1) Form C 2A relay Alarm (1) Form C 2A relay Communications RS232 & Bluetooth Indicators Front panel LED Power (blue), Flow (white), Alarm (red) Keypad Display 16 button keypad, 4 softkey (A, B,C,D), ON/OFF button. Oil resistant, sealed. 240x128 full graphic LED with back light Automatic LCD bias control, self-regulating non-sweating temperature activated heater Power External 9-26 VDC, self-resetting fuse 0.6A with heater OFF, 1.6A with heater ON Transient protection Internal Rechargeable NiMH battery pack. Maintains power for up to 10 seconds after power loss. Typical service live: up to 5 years Physical & Environmental Operating temperature -40 to +50ºC, humidity 5-95% non-condensating Sealed, shock vibration tested enclosure 9.75(L) X 7.50 (H) X 3.75 (W) max size and 4 lbs max weight Miscellaneous SOFTWARE System Integrity Sensor Resolution Math Processing Overall Error Power Management Real time clock with daylight savings time, dual 8 MHz CPU's, 1M Flash/64K RAM, Watchdog timer, 8 channel 12 bit Hi-speed ADC. Buffered serial port, FIFO CPU communication. Built-in diagnostics for all hardware. Power-on self test Constant system monitoring of inputs and sensors RTD -.04 ohms approx Loop-.006mA approx. Internal floating point, 15 digits of precision. Calculations carried out in FP for max precision.0001% max (excludes uncertainty of temperature & pressure probe) CPU extinguishes backlight when operating on internal battery. Auto shutdown after 10 sec power loss 2009-Turbines, Inc.-All Rights Reserved Page 10 CDS 1000-QRG.xls

11 Troubleshooting 1) Observe "ALARM" list by pressing "D". 2) Check the following: a) all connections are secure b) Cables are not split or frayed c) Power source is connected to the truck battery d) No water is present in connectors 3) NOTE: If "Totalize During Alarm is "OFF", disable. Got to "Programming and follow instructions: 3) Changes System Setting 2) Alarm & Timer Settings 4) Then proceed as follows: 4-1) Low Power a) Check source connection. b) Check cable. 4-2) Low Batt a) Check battery connection b) Replace battery 4-3) Coil Short a) Check signal cable connection b) Check cable continuity-no reading, replace cable c) Cable passed- check coil ohms- no reading or out of range, replace coil 4-4) Coil Open a) Check signal cable connection b) Perform signal test Remove pickup coil from turbine meter. Reconnect signal cable to coil. With a screw driver, rapidly scratch coil below the threads on the smooth surface. Observe "signal" light slightly illuminates. If yes, go to "observe turbine meter for failure" c) Check coil ohms- no reading or out of range, replace coil 4-5) RTD Short a) Check probe cable connection b) Check cable continuity- no reading, replace cable c) Cable passed- check probe ohms- no reading or out of range, replace temperature probe. 4-6) RTD Open a) Check probe cable connection b) Check cable continuity- no reading, replace cable c) Cable passed- check probe ohms- no reading or out of range, replace temperature probe. 4-7) Maintenance Due Go to "Programming" follow instructions to reset maintenance. 3) Changes System Setting 5) Maintenance 5) Check turbine meter a) Remove turbine from line and observe the following: 1) Rotor spins freely, if NO, STOP, consult factory 2) No wobble, it YES, STOP, consult factory 3) internals appear in tack, if NO, STOP, consult factory For all other issues, contact factory Turbines, Inc.-All Rights Reserved Page 11 CDS 1000-QRG.xls

12 Illustrations 2009-Turbines, Inc.-All Rights Reserved Page 12 CDS 1000-QRG.xls

13 Illustrations 2009-Turbines, Inc.-All Rights Reserved Page 13 CDS 1000-QRG.xls

Model CDS1000. Installation and Operation Also covers the CDS1000-B

Model CDS1000. Installation and Operation Also covers the CDS1000-B Model CDS1000 Installation and Operation Also covers the CDS1000-B PO Box 933, 15935 US Hwy 283 N. Altus, OK 73522-0933 Seneca: 864-882-4544 http://turbinesincorporated.com Manual part number 900484 Revision

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS. The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

INSTALLATION & OPERATION MANUAL. MODEL TPS1500 Calibration Proving System

INSTALLATION & OPERATION MANUAL. MODEL TPS1500 Calibration Proving System INSTALLATION & OPERATION MANUAL MODEL TPS1500 Calibration Proving System 2 METER PROVER OPERATION-COMPREHENSIVE WARNING Never drop any component of the prover system; carefully place each component in

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

Electronic SD1, AS 8, ASR 14, ASR 20

Electronic SD1, AS 8, ASR 14, ASR 20 Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................

More information

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters DESCRIPTION Pump-Down Controller Input Scalable Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters The Model 4052 Pump-Down Controller provides total control for duplex pumping

More information

RST INSTRUMENTS LTD.

RST INSTRUMENTS LTD. Carlson/RST MA-7 Readout Instruction Manual 1 RST INSTRUMENTS LTD. Carlson/RST MA-7 Readout Instruction Manual Ltd. 11545 Kingston St Maple Ridge, BC Canada V2X 0Z5 Tel: (604) 540-1100 Fax: (604) 540-1005

More information

B2800 FLOW MONITOR. - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version

B2800 FLOW MONITOR. - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version B2800 FLOW MONITOR - For Liquid Meters - PROGRAMMING & INSTALLATION MANUAL Simplified Version 8635 Washington Avenue Racine, Wisconsin 53406 Technical Toll-Free: 877.722.4631 Sales Toll-Free: 800.235.1638

More information

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ300 Wall Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

LCI User Manual mantracourt.com

LCI User Manual mantracourt.com LCI User Manual mantracourt.com LCI Load Cell Junction Box with Fault Monitor Contents Chapter 1 Introduction to the LCI... 2 Chapter 2 Installing the LCI... 3 Chapter 3 Setting up the LCI... 4 Sequence

More information

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Water Quality Meter. Water Quality Meter Kit. Instruction Manual Water Quality Meter 850081 Water Quality Meter Kit 850086 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax:

More information

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual PG5 Digital Pressure Gauge DOC. 9003264 Rev. A1 3/10 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com PG5

More information

PIECAL 520B & 521B Thermocouple Source Operating Instructions

PIECAL 520B & 521B Thermocouple Source Operating Instructions PIECAL 520B & 521B Thermocouple Source Operating Instructions (Shown without optional boot) Product Description (Shown with optional boot) Easy to use With the PIECAL 520B/521B you can check & calibrate

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions http://www.kep.com KESSLER-ELLIS PRODUCTS 10 Industrial Way East Eatontown, NJ 07724 800-631-2165 732-935-1320

More information

Operations Manual EcoSense ph100

Operations Manual EcoSense ph100 Operations Manual EcoSense ph100 Portable ph, mv and Temperature Instrument English Français Español Deutsch Italiano WARRANTY The EcoSense ph100 Instrument is warranted for one year from date of purchase

More information

Type K/J Thermometers

Type K/J Thermometers Type K/J Thermometers 800005 CONTENTS INTRODUCTION....2 FRONT PANEL DESCRIPTION...3 LCD DISPLAY....4 OPERATION INSTRUCTION...5 Power Up....5 Connecting the Thermocouples....5 Selecting Temperature Scale....5

More information

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22 Samba PLC+HMI SM35-J-TA22 SM43-J-TA22 SM70-J-TA22 Technical Specifications Ordering Information Item SM35-J- TA22 PLC with Flat panel, Color touch display 3.5 SM43-J- TA22 PLC with Flat panel, Color touch

More information

Sidewinder Pumps Inc. AC Timer/Controller

Sidewinder Pumps Inc. AC Timer/Controller Sidewinder Pumps Inc. AC Timer/Controller Page 1 of 12 Rev 032417 Table of Contents 1. Warnings-------------------------------------------------------------------------------------------------- 3 1.1.

More information

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP. DIVERSIFIED HEAT TRANSFER SERIES 700 STEAM GENERATOR CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE AT SIGMACONTROLS.COM SERIES 700 DHT STEAM GENERATOR MANUAL 042514 2 TABLE OF CONTENTS INTRODUCTION.

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL IT200N REV. D Remote Rate Indicator DOC#: MN-200N-D.doc Sponsler, Inc. IT200N Remote Rate Indicator pg. 2 DOC#: MN-200N-D.DOC TABLE OF CONTENTS PAGE # SPECIFICATIONS...

More information

Samba PLC+HMI SM35-J-RA22

Samba PLC+HMI SM35-J-RA22 Samba PLC+HMI SM35-J-RA22 SM43-J-RA22 Technical Specifications Ordering Information Item SM35-J-RA22 PLC with Flat panel, Color touch display 3.5 SM43-J-RA22 PLC with Flat panel, Color touch display 4.3

More information

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. IQ240 Panel Mount Load Cell Indicator Data sheet English 1.01 Introduction The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD User s Guide OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD OM-CP-PRHTEMP2000 Product Overview The OM-CP-PRHTEMP2000 is a pressure, temperature and humidity data logger with

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL STATIC METERS Models 211 & 212 SURVEYORSTAT Models 211XL & 212XL Operating Manual 5/09 1.0 GENERAL DESCRIPTION The Model 211 and 212 Static Meters, shown in Figures 1.0-1a and b, are accurate, compact

More information

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual

Manual. NanoTron Dual Timer. Installation Maintenance Repair Manual Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56" (14.2 mm) or 1.20" (30.5 mm) Linear or Square Root with Low-Flow Cutoff

More information

MRDT Display Terminal

MRDT Display Terminal www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205 MRDT Display Terminal Installation and Specifications: This device complies with part 15 of the FCC

More information

MTS-2000 USER S MANUAL

MTS-2000 USER S MANUAL MTS-2000 USER S MANUAL USER s MANUAL - March 2010 MTS-2000 METER TEST SYSTEM Pay special attention to the warnings and safety instructions that accompany the above symbol wherever it is found within this

More information

WS115 BREAKOUT ADAPTER USER MANUAL

WS115 BREAKOUT ADAPTER USER MANUAL STATIC WATER LEVEL MEASUREMENT WS115 BREAKOUT ADAPTER USER MANUAL www.enoscientific.com Page 1 Eno Scientific 1606 Faucette Mill Rd Hillsborough, NC 27278 USA www.enoscientific.com 910-778-2660 Copyright

More information

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. LT1300 Wall Mount Load Cell Indicator Datasheet English 1.00 Introduction The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications. The high

More information

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction User's Guide Vane Thermo-Anemometer Datalogger Model 451126 Introduction Congratulations on your purchase of Extech's Thermo-Anemometer Datalogger. This Vane-type Anemometer can indicate Air Velocity in

More information

SP6R Level Controller Operation Manual

SP6R Level Controller Operation Manual SP6R Level Controller Operation Manual www.sjerhombus.com SP6R LEVEL CONTROLLER INTRODUCTION SJE-Rhombus, an industry leader in water and wastewater pump controls, introduces the SP6R Level Controller.

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Display: EZ100 11/12/04-1 - Congratulations on your purchase of the EZ100 Display.

More information

ME15 Magnetic Encoder Manual Revision 1.1

ME15 Magnetic Encoder Manual Revision 1.1 Product Overview The ME15 Magnetic Encoder is the newest addition to AMCI s Encoder product line. The encoder is designed for lower resolution and lower cost applications and provides 10 bits of resolution.

More information

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series The Digitec Series D3800 Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. The D3820 and D3830 are available in the ranges of 4-20mA, 0-10 VDC,

More information

Quick Start Guide MC-III TM Flow Analyzer

Quick Start Guide MC-III TM Flow Analyzer Quick Start Guide MC-III TM Flow Analyzer A Quick Reference on Mounting, Wiring, & Configuring the MC-III EXP or WP Flow Analyzer For complete instructions, see MC-III EXP User Manual, Part No. 9A-50165003

More information

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction

User's Guide. Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model Introduction User's Guide Programmable DC Power Supply 200 Watt (40 Volts / 5 Amps) Model 382280 382280 Introduction Congratulations on your purchase of the Extech 382280 Programmable DC Power Supply. This 200 watt

More information

PIECAL 510B/511B RTD Simulator Operating Instructions

PIECAL 510B/511B RTD Simulator Operating Instructions PIECAL 510B/511B RTD Simulator Operating Instructions (Shown without optional boot) (Shown with optional boot) Product Description Easy to use With the PIECAL 510B/511B you can check & calibrate all your

More information

NF770 Temperature Compensation Liquid Flow Computer

NF770 Temperature Compensation Liquid Flow Computer NF770 Temperature Compensation Liquid Flow Computer Overview Mass Flow measurement at a comparatively low cost can be achieved using the Model NF770 Liquid Flow Computer, an RTD temperature sensor and

More information

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00 GF-1 +-10G Tilt Compensated dual range aviation G-force meter Operating Manual English 1.00 Introduction The GF-1 is a 2.25 G-force meter capable of measuring G-forces exerted in an aircraft up to +-10G.

More information

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL Transducer Techniques R 42480 RIO NEDO, TEMECULA, CA 92590 (909) 719-3965 FAX (909) 719-3900 URL: http://www.ttloadcells.com E-mail: tti@ttloadcells.com

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

AE21 SERIES DISPLAY CONTROL TERMINAL

AE21 SERIES DISPLAY CONTROL TERMINAL FN:AE21MAN1.DOC AE21 SERIES DISPLAY CONTROL TERMINAL DESCRIPTION The AE21 Series Display Control Terminal is used for implementing various display functions. It consists of a control terminal, the AE21,

More information

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 User Guide Model 42265 Temperature Datalogger Kit Model 42275 Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276 Introduction Congratulations on your purchase of Extech Instrument

More information

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller Operation Manual TX10 1/8 DIN Microcomputer Based /ORP Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING THE Sensorex

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

4-Channel Datalogging Thermometer

4-Channel Datalogging Thermometer 4-Channel Datalogging Thermometer 800024 4-Channel Datalogging Thermometer - 800024 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA The contents of this manual may not be reproduced

More information

GFC114. Low Power Flow Computer FEATURES

GFC114. Low Power Flow Computer FEATURES Low Power Flow Computer FEATURES l UNIVERSAL INPUT, 5 khz, CAN POWER THE l SIMPLIFIED MENUS AND PROGRAMMING l NO NEED OF AMPLIFIERS OR LINEARIZERS l SEVEN DIGIT RATE WITH PROGRAMMABLE DECIMAL PLACES l

More information

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Dissolved Oxygen Meter Kit DOK. Instruction Manual Dissolved Oxygen Meter Kit 850081DOK Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax: 0-3844-6200 Email:

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10 AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual PG-5 Full Access DOC. 9003384 Rev. A1 3/10 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com PG5 Rev.

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR

INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR INSTALLATION PROCEDURE FOR THE INNOVEC IPT POWERED PRINTING TOTALISOR Suite 5, 56-6 Chandos Street, St. Leonards NSW 065/PO Box 35 Spit Junction NSW 088 Australia Phone +6 9906 758 www.innovec.com page

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

GFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS

GFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS Flow Computer With RS485 MODBUS FEATURES l RS485 MODBUS RTU, 1/8 LOAD l PROGRAMMABLE ADDRESS, BAUD RATE, PARITY AND STOP BITS l UNIVERSAL INPUT, 5 khz, CAN POWER THE SENSOR l NO NEED OF AMPLIFIERS OR LINEARIZERS

More information

PWRguard PLUS Spring City Drive Waukesha, WI

PWRguard PLUS Spring City Drive Waukesha, WI PWRguard PLUS www.westmountainradio.com 1020 Spring City Drive Waukesha, WI 53186 262-522-6503 sales@westmountainradio.com 2016, All rights reserved. All trademarks are the property of their respective

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL DT-118B MTP INSTRUCTION MANUAL Pocket Autoranging Digital Multimeter 3 in 1 Model MTP-1025 Auto Ran ging DMM Hz% A OFF V AU TO PO WER OFF MTP Instruments Table of Contents Introduction Page 1 Features

More information

AirPro Surveyor 2 Manual

AirPro Surveyor 2 Manual AirPro Surveyor 2 Manual AirPro Surveyor Specifications Table of Contents Size 3/8 x 7 1/2 x 4 3/8 Weight 4.6 lbs. 2094 g Dynamic Range 1-1000 ml/min. total flow/constant flow Flow Capacity (8 Hrs.) 1000

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_3_1 Easy-to-use, w-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs Vision OPLC V130-33-RA22 Technical Specifications This guide provides specifications for Unitronics model V130-33-RA22. General features include: 12 pnp/npn Digital, including 2 Analog, 2 PT100/TC, 1 HSC/Shaft-encoder

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

The GF-2 is able to measure G-forces even if the instrument is not mounted exactly on the vertical axis of the aircraft.

The GF-2 is able to measure G-forces even if the instrument is not mounted exactly on the vertical axis of the aircraft. GF-2 +-10g Tilt Compensated dual range aviation G-force meter Operating Manual English 1.00 Introduction The GF-2 is a 3 1/8 G-force meter capable of measuring G-forces exerted in an aircraft up to +-10g.

More information

MICRO GROW GREENHOUSE SYSTEMS, INC

MICRO GROW GREENHOUSE SYSTEMS, INC MICRO GROW GREENHOUSE SYSTEMS, INC 4065 ZEVO DR., UNIT B-, TEMECULA, CA 9590 PHONE (95) 96-3340 FAX (95) 96-3350 www.microgrow.com Revision., -09-0 Growstat Control Series INSTALLATION PROCEDURES SERIES

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA PD10 Pulse Divider Instructions PROUDLY MADE IN THE USA ISO 001:200 Certified Company General Information General Information...Page 3 Features...Page 3 Specifications...Page 4 Installation Mounting...Page

More information

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual Model CR103J DC Current and Voltage Calibrator/Standard ±0.01µA to ±111.1110mA ±0.1µV to ±11.11110V Operating Manual This page intentionally left blank. CR103J OPERATORS MANUAL Serial No. This page intentionally

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

USER'S MANUAL DCL-650

USER'S MANUAL DCL-650 USER'S MANUAL Clamp on Multimeter - Compact Design True RMS AC/DC DCL-650 CIRCUIT-TEST ELECTRONICS www.circuittest.com Safety International Safety Symbols This symbol, adjacent to another symbol or terminal,

More information

TR100-A / TR200-A. Temperature / Humidity Data Loggers. Users Manual. For detailed specifications and ordering info go to

TR100-A / TR200-A. Temperature / Humidity Data Loggers. Users Manual. For detailed specifications and ordering info go to TR100-A / TR200-A Temperature / Humidity Data Loggers Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com TR100-A / TR200-A Temperature / Humidity Data Loggers English

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value. Vision OPLC V350-35-TA24/V350-J-TA24 Technical Specifications The Unitronics V350-35-TA24/V350-J-TA24 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog,

More information

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1 POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.

More information

OPERATING MANUAL TCAT-2DF CONTROLLER PHYSITEMP INSTRUMENTS INC. 154 Huron Avenue Clifton NJ USA Tel: Fax:

OPERATING MANUAL TCAT-2DF CONTROLLER PHYSITEMP INSTRUMENTS INC. 154 Huron Avenue Clifton NJ USA Tel: Fax: PHYSITEMP INSTRUMENTS INC 154 Huron Avenue Clifton NJ 07013 USA Tel: 973-779-5577 Fax: 973-779-5954 OPERATING MANUAL TCAT-2DF CONTROLLER APPENDIX 2: Installation instructions for HP-1M and HP-4M warming

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil

More information

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS

AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS FN:XXMFCT1.DOC AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS AEXX SERIES MULTI-FUNCTION CLOCK/TIMERS REV 04/09/09 DESCRIPTION The AEXX Series of Multi-Function Clock/Timers are available with 1, 2.3, 4, 8, or

More information

User's Manual Sound Level Alert Model SL130

User's Manual Sound Level Alert Model SL130 User's Manual Sound Level Alert Model SL130 Meets ANSI and IEC Type 2 Sound Level Meter Standards Settable High Limit with large bright High/Low indication and Alarm Output Wall or Desk mountable Extra

More information

Dattus can communicate via Modbus RTU protocol. It is designed to be compatible with SCADA and other equipment that communicates via Modbus

Dattus can communicate via Modbus RTU protocol. It is designed to be compatible with SCADA and other equipment that communicates via Modbus Dattus T M Basic & Commercial & Industrial Gas Meters Applications The Dattus meter is a highly accurate solid-state gas meter suited for commercial & industrial gas measurement applications for flow rates

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT 1 INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT TABLE OF CONTENTS 1 INSTALLATION... 2 1.1 Mounting... 2 1.2 Mains Connection... 2 1.3 Relay Connection... 3 1.4 Pulse Input Connection... 3 1.5 4-20 ma Output

More information

DST550 Digi-Stem Thermometer

DST550 Digi-Stem Thermometer DST550 Digi-Stem Thermometer User Manual 09/16/09 WD1045 Rev C Wahl Instruments, Inc. 234 Old Weaverville Road Asheville, NC 28804 Toll Free 800-421-2853 Phone 828-658-3131 Fax 828-658-0728 www.palmerwahl.com

More information

Installation Manual. Flow Max 110

Installation Manual. Flow Max 110 Installation Manual Flow Max 110 OPERATION Turn on Console by depressing ON. NOTE: This Console is equipped with a Power Down feature. The Power Down feature turns OFF the Console if no flow is sensed

More information

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020 USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_2_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

PowerCore Model TEC-10 Installation Manual

PowerCore Model TEC-10 Installation Manual PowerCore Model TEC-10 Installation Manual Products covered in this document comply with European Council electromagnetic compatibility directive 2014/30/EU and electrical safety directive 2014/35/EU.

More information

TC100 Precision Thermocouple Calibrator

TC100 Precision Thermocouple Calibrator TC100 Precision Thermocouple Calibrator Table of Contents 1. Introduction.....................1 2. Accessories....................5 3. Set-Up Basic/Advanced...........5 4. Operating Procedure.............6

More information

User's Guide. Cup Thermo-Anemometer. Model AN400

User's Guide. Cup Thermo-Anemometer. Model AN400 User's Guide Cup Thermo-Anemometer Model AN400 Introduction Congratulations on your purchase of the Extech Cup Thermo-Anemometer. The AN400 measures air velocity in five units of measure: feet per minute

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_4_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code LARGE DISPLAYS BCD CODE Series BDF LARGE DISPLAYS for parallel BCD code BDF-xx-BCD for parallel BCD code FEMA ELECTRÓNICA IDEAL SOLUTION to display numerical values at long distances, controlled by parallel

More information

User's Guide. Model High Precision Quad Output DC Power Supply

User's Guide. Model High Precision Quad Output DC Power Supply User's Guide Model 382270 High Precision Quad Output DC Power Supply Introduction Congratulations on your purchase of the Extech 382270 DC Power Supply. The Model 382270 can be used for many applications

More information