1 Data Sheet Miniature Circuit Breaker Comb Bus Bar 489 & na.noark-electric.com
2 NOARK 489/1077 Features 489 Miniature Circuit Breakers Comb Bus Bar: Available for 1, 2 and 3 poles Available in 80 A and 100 A ratings Voltage ratings: 1 pole: 1,000 Vac/dc 2 and 3 poles: 600 Vac/dc Center Feed rating up to 200 A (two 115 A terminals requried per pole) Feeder Terminal options allow for Top or Bottom Feed as standard Cuttable design allows for maximum flexibility and less waste Finger safe design with available Protective Caps for unused terminals Supplementary Protectors Comb Bus Bar: Available for 1, 2 and 3 poles Available in 80 A and 100 A ratings Voltage ratings: 1 pole: 600 Vac, 1,000 Vdc 2 and 3 poles: 600 Vac/dc Center Feed rating up to 200 A (two incoming terminals requried per pole) Feeder Terminal options allow for Top or Bottom Feed Cuttable design allows for maximum flexibility and less waste Finger safe design with available Protective Caps for unused terminals Certifications 489/508 Listed CE Compliant RoHS Compliant NOARK Electric
3 489/1077 Selection Guide Selection Guide CB A 1P 06P 18 Rated Pole Pin Type Cross Section mm 2 Device Catagory Bus Bar A: 489 1P: 1 Pole 06P: 6 Pins 18: 18 (80 A) : For 489 MCB B: P: 2 Poles 12P: 12 Pins 25: 25 (100 A) Blank: For MCB 3P: 3 Poles 18P: 18 Pins 56P: 56 Pins (for 2-pole only) 57P: 57 Pins All Rights Reserved 3
4 489/1077 Specifications and Dimensions Voltage Ratings Current Ratings Pole 2 & 3 Poles 1 Pole 2 & 3 Poles Maximum AC Voltage (Vac) 600 1, Maximum DC Voltage (Vdc) 1, Maximum Current 18 mm 2 Cross Sections (A) Maximum Current 25 mm 2 Cross Sections (A) End Feed 80 Center Feed 160 End Feed 100 Center Feed 200 Protection Class IP 20 J Fuse Rating (ka) Dimensions CBA 489 Unit: in. [mm] NOARK Electric
5 489/1077 Accessories: Dimensions CBB Unit: in. [mm] All Rights Reserved 5
6 489/1077 Accessories: Selection Guide Feeder Terminal Terminal installed behind bus bar allows for reduced depth Terminal installed in front of bus bar allows for reduced height Selection Guide FD 50 Dimensions FD: Feed Terminal 35: 35 mm 2 (Top Feed) 489 / 489A Top Feed FD35 50: 50 mm 2 (Bottom Feed) Blank: Bottom Feed (FD50) TC8021 (Top Mount) TM S EC489/1077 (End Cap) EC Poles Pole TM: Top Mount Terminal 8021: 50S: 1 Pole (Rear Mount) EC: End Cap 489 / 489A 1: 1 Pole 53S: 1/2/3 Poles (Front Mount) 3: 2-3 Pole 80: 2/3 Poles (Rear Mount) PC 489 PC489 (Protective Cap 489) PC: Protective Cap 489 / 489A PC1077 (Protective Cap NOARK Electric
7 489/1077 Comb Bus Bar Installation Guide CBA Accessories 489 Unit: in. [mm] Protective Caps (PC489) Z2 Center/Bottom Feed Terminal 1-3P (FD50) SW4 Endcap 1-3P (EC489) Terminal 1-3P (FD35) CBB Accessories Unit: in. [mm] Protective Caps (PC1077) 1 Front Mount Terminal 1-3P (TM802153S) 3 2 Center/Bottom Feed Terminal 1-3P (FD50) Z2 Z2 1. Rear Mount Terminal 1P (TM802150S) Rear Mount Terminal 2-3P (TM802180) Endcap 1P (EC10771) Endcap 2-3P (EC10773) 1.1 All Rights Reserved 7
8 489/1077 Ordering Guide Product Part Number Poles Pins Cross Section CBA1P06P Comb Bus Bar 1 6 pins 18 mm² CBA1P12P Comb Bus Bar 1 12 pins 18 mm² CBA1P18P Comb Bus Bar 1 18 pins 18 mm² CBA1P57P Comb Bus Bar 1 57 pins 18 mm² CBA1P06P Comb Bus Bar 1 6 pins 25 mm² CBA1P12P Comb Bus Bar 1 12 pins 25 mm² CBA1P18P Comb Bus Bar 1 18 pins 25 mm² CBA1P57P Comb Bus Bar 1 57 pins 25 mm² CBA2P06P Comb Bus Bar 2 6 pins 18 mm² CBA2P12P Comb Bus Bar 2 12 pins 18 mm² CBA2P18P Comb Bus Bar 2 18 pins 18 mm² CBA2P56P Comb Bus Bar 2 56 pins 18 mm² CBA2P06P Comb Bus Bar 2 6 pins 25 mm² CBA2P12P Comb Bus Bar 2 12 pins 25 mm² CBA2P18P Comb Bus Bar 2 18 pins 25 mm² CBA2P56P Comb Bus Bar 2 56 pins 25 mm² CBA3P06P Comb Bus Bar 3 6 pins 18 mm² CBA3P12P Comb Bus Bar 3 12 pins 18 mm² CBA3P18P Comb Bus Bar 3 18 pins 18 mm² CBA3P57P Comb Bus Bar 3 57 pins 18 mm² CBA3P06P Comb Bus Bar 3 6 pins 25 mm² CBA3P12P Comb Bus Bar 3 12 pins 25 mm² CBA3P18P Comb Bus Bar 3 18 pins 25 mm² CBA3P57P Comb Bus Bar 3 57 pins 25 mm² FD Top Feed Terminal mm² FD Bottom Feed Terminal mm² EC End Cap PC Protective Cap CBB1P06P Comb Bus Bar 1 6 pins 18 mm² CBB1P12P Comb Bus Bar 1 12 pins 18 mm² CBB1P18P Comb Bus Bar 1 18 pins 18 mm² CBB1P57P Comb Bus Bar 1 57 pins 18 mm² CBB1P06P Comb Bus Bar 1 6 pins 25 mm² CBB1P12P Comb Bus Bar 1 12 pins 25 mm² CBB1P18P Comb Bus Bar 1 18 pins 25 mm² CBB1P57P Comb Bus Bar 1 57 pins 25 mm² CBB2P06P Comb Bus Bar 2 6 pins 18 mm² CBB2P12P Comb Bus Bar 2 12 pins 18 mm² CBB2P18P Comb Bus Bar 2 18 pins 18 mm² CBB2P56P Comb Bus Bar 2 56 pins 18 mm² CBB2P06P Comb Bus Bar 2 6 pins 25 mm² CBB2P12P Comb Bus Bar 2 12 pins 25 mm² CBB2P18P Comb Bus Bar 2 18 pins 25 mm² CBB2P56P Comb Bus Bar 2 56 pins 25 mm² CBB3P06P Comb Bus Bar 3 6 pins 18 mm² CBB3P12P Comb Bus Bar 3 12 pins 18 mm² CBB3P18P Comb Bus Bar 3 18 pins 18 mm² CBB3P57P Comb Bus Bar 3 57 pins 18 mm² CBB3P06P Comb Bus Bar 3 6 pins 25 mm² CBB3P12P Comb Bus Bar 3 12 pins 25 mm² CBB3P18P Comb Bus Bar 3 18 pins 25 mm² CBB3P57P Comb Bus Bar 3 57 pins 25 mm² FD Bottom Feed Terminal mm² PC Protective Cap TM802150S Top Feed Terminal 1-35 mm² TM802153S Top Feed Terminal 1/2/3-35 mm² TM Top Feed Terminal 2/3-35 mm² EC End Cap EC End Cap 2/ NOARK Electric
9 NOARK Electric North America (626) na.noark-electric.com Note: NOARK Electric reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. NOARK Electric nor any of its affiliates or subsidiaries shall be responsible or liable for potential errors or possible lack of information in this document. NOARK Electric reserves all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of NOARK Electric NOARK Electric All Rights Reserved DSBB201712NA
Catalog DIN Rail Miniature Circuit Breakers Ex9 Series - B1
Catalog DIN Rail Miniature Circuit Breakers Ex9 Series - B1 B1E4C16 B1H1C16 B1NQ30 na.noark-electric.com NOARK Electric Electrical Equipment Manufacturer for Distribution and Control NOARK Electric is
More informationUS CATALOG SMISSLINE TP
US CATALOG SMISSLINE TP 2 SMISSLINE TP US CATALOG SMISSLINE TP US CATALOG 3 Table of contents 004 Description 005 012 for UL 508 and UL 489 based solutions Overview and ordering information 013 014 for
More informationCatalog DIN Rail Miniature Circuit Breakers Ex9 Series - B1
Catalog DIN Rail Miniature Circuit Breakers Ex9 Series - B1 B1E4C16 B1A1C16 B1NQ30 na.noark-electric.com NOARK Electric Electrical Equipment Manufacturer for Distribution and Control NOARK Electric is
More informationUS Catalog July 2016 SMISSLINE TP
US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)
DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationApplication Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400
Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current
More informationFor Sales and Support call KMParts.com (866)
Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping
More informationAccessories for pluggable interface relays CR-U Pluggable function modules
Data sheet Accessories for pluggable interface relays CR-U Pluggable function modules 2CDC 291 004 S0011 Characteristics Pluggable function modules for mounting on the sockets CR-U2S and CR-U3S modules:
More informationJtec 10kA Miniature Circuit Breaker
Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide
More informationMiniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.
Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers
More informationST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077
MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary
More information1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors
. Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................
More informationSelection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationMiniature Circuit Breakers and Supplementary Protectors. Contents
. Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.
More informationAccessories for pluggable interface relays CR-P, CR-M Pluggable function module
Data sheet Accessories for pluggable interface relays CR-P, CR-M Pluggable function module 2CDC2 91 005 S0011 Characteristics Pluggable function modules for mounting on logical and standard sockets for
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationUS BROCHURE. Circuit protection according to UL 489 and UL 1077
US BROCHURE Circuit protection according to UL 489 and UL 1077 2 CIRCUIT PROTECTION UL 489 AND UL 1077 CIRCUIT PROTECTION UL 489 AND UL 1077 3 Table of contents 004 006 Introduction 007 008 Product selction
More informationSupplementary Circuit Protectors Type GSB63
Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up
More informationMG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD
United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationProduct Guide. UL 1077 DIN Rail Supplementary Protectors
Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................
More informationFAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview
FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors
More informationUL 489 DIN rail branch circuit breakers
UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product
More informationXCMD21F0L2 limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m
Characteristics limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m Complementary Switch actuation Electrical connection Cable length Cable composition Wire insulation material Contacts insulation
More informationTEPI11 P/I signal converter
Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationString monitoring with CMS - Circuit monitoring system Increased productivity and improved maintenance of PV systems
S O L A R S T R I N G M O N I TO R I N G String monitoring with CMS - Circuit monitoring system Increased productivity and improved maintenance of PV systems Solar plant operators are constantly facing
More information24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD
United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated
More informationBus Connection Unit 560BCU04
Bus Connection Unit 560BCU04 Application The Bus Connection Unit 560BCU04 R0001 is designed to make the RTU560s TSI, TSO, Alarm and Warning signals accessible to the outside. By using the bus connection
More informationAccessories for pluggable interface relays CR-P Sockets
Data sheet Accessories for pluggable interface relays CR-P Sockets Characteristics Logical and standard socket for pluggable interface relays CR-P Snap-on mounting on DIN rail Connector for pluggable function
More information60103 Circuit Breaker
6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard
More informationBoxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories
Data sheet Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories Boxed interface relays and optocouplers are used for electrical isolation, amplification and signal
More informationABB i-bus KNX HCC/S Heating/cooling circuit controller
ABB i-bus KNX HCC/S 2.2.1.1 Heating/cooling circuit controller Description of product The device is a modular DIN rail component (MDRC) in pro M design. It is intended for installation in distribution
More informationABB i-bus KNX BCI/S Boiler/Chiller Interface
ABB i-bus KNX BCI/S 1.1.1 Boiler/Chiller Interface Description of product The boiler/chiller interface is a modular DIN rail component that acts as an interface to the heating/cooling system generator.
More informationRTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.
Binary Output 23BO62 Characteristics The binary output is made via relay contacts. The 8 outputs are potential isolated against the electronic by optocoupler. All 8 outputs have a separate return. Application
More informationXCMN2102L2 limit switch XCMN - steel roller plunger - 1NC +1NO - snap - 2 m
Characteristics limit switch XCMN - steel roller plunger - 1NC +1NO - snap - 2 m Complementary Switch actuation Electrical connection Cable length Cable composition Wire insulation material Contacts insulation
More informationINDI BOY DSP Load limitation electronics
Change from one to two columns Data Sheet DS/INDI-BOY-DSP-EN Rev. A INDI BOY DSP Load limitation electronics Load limitation with 3 set points and display to be installed on a front panel Measurement made
More information1492-SP Supplementary Protectors
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationRedundancy unit CP-A RU
2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power
More informationClose Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors
Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...
More information1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers
.2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................
More informationABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011
Tecnical Data 2CDC 502 079 D0201 ABB i-bus KNX Gateway for integration of EnOcean devices into KNX TP-1 (EIB) control systems and vice versa. The ABB allows a complete and natural integration of EnOcean
More informationAC 800M for Compact Product Suite Outline of all modules
DATA SHEET AC 800M for Compact Product Suite Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose
More informationRTU560 Connections and Settings DIN Rail RTU 560CIG10
Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail
More informationUEMC 41 Motor Operating Device
Installation and operating instructions UEMC Motor Operating Device Your safety first always! All legally recognized standards, the connection conditions of the local electrical utility and the applicable
More informationThe new Arc Fault Detection Device S-ARC1 Maximum safety easy installation
ARC FAULT DETECTION DEVICE (AFDD) The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation The S-ARC1 is the new Arc Fault Detection Device (AFDD) with an integrated Miniature Circuit
More informationXUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm
Characteristics XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range
More informationCharacteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01
HMI unit 560HMR01 Characteristics Application The 560HMR01 is a rack based human machine interface board of the RTU560 system. The essential tasks of the 560HMR01 are: Interface to RTUs that are running
More informationCANADIAN CATALOG JANUARY SENTRICITY Loadcentres and Circuit Breakers Raising the standard in residential.
CANADIAN CATALOG JANUARY 208 Loadcentres and Circuit Breakers Raising the standard in residential. 2 S E N T R I C I T Y T M L O A D C E N T R E S A N D C I R C U I T B R E A K E R S - C A N A D I A N
More informationSwitching relay CT-IRE with 1 c/o (SPDT) contact
Data sheet Switching relay CT-IRE with 1 c/o (SPDT) contact The CT-IRE is a switching relay from the CT-E range. The CT-E range is the economic range of ABB s time relays and offers a cost effective price-performance
More informationRXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A
Characteristics miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A Complementary [Ui] rated insulation voltage Main Range of product Series name Product or component type Device short name Contacts
More informationXUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm
Characteristics XUSL type 4 - Body protection - Long sensing range 510 mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range of product Product
More informationABB i-bus KNX AC/S Application Controller
ABB i-bus KNX AC/S 1.2.1 Application Controller Description of product Automation controller with pre-defined automation modules for comprehensive heating, ventilation and air conditioning automation (HVAC
More informationElectronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact The CT-ARE is an electronic time relay with OFF-delay. It is from the CT-E range. The CT-E range is the economic
More informationElectronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and
More informationLMC058LF42 compact base - 42 I/O - 24 V DC supply
Characteristics compact base - 42 I/O - 24 V DC supply Main Commercial Status Range of product Product or component type Product specific application Discrete I/O number 42 Commercialised Modicon LMC058
More informationPluggable interface relays CR-M Miniature relays
Data sheet Pluggable interface relays CR-M Miniature relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC
More informationSafety light beam Spot
Safety light beam is a light beam mainly used for body detection. It consists of a transmitter and a receiver. Infrared light is sent from the transmitter to the receiver and when the light beam is interrupted
More informationPluggable interface relays CR-P Pcb relays
Data sheet Pluggable interface relays CR-P Pcb relays Pluggable interface relays are used for electrical isolation, amplification and signal matching between the electronic controlling, e.g. PLC (programmable
More informationXCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11
Characteristics limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11 Complementary Tracks Switch actuation Electrical connection Contacts insulation form Positive opening Positive opening
More informationRTU500 series Data Sheet Power Supply CP-E 24/2.5
Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped
More informationElectronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.
More informationCoded Non-Contact Safety Sensor Eden OSSD
Coded Non-Contact Safety Sensor Eden OSSD Approvals: Application: Door and hatches Position control Sector detection Features: Non-contact detection, 0-15 mm OSSD outputs and inputs for serial connection
More informationRSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A
Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A Complementary Shape of pin Main Range of product Series name Product or component type Device short name Contacts type and composition
More informationXUSL4E30H151N XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm
Characteristics XUSL type 4 - For hand protection - Std sensing range - Hp = 1510 mm, R=30mm Complementary Detection system Response time Kit composition [EAA] effective aperture angle Emission Main Range
More informationRedundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)
Data sheet Redundancy unit Accessory for CP range power supplies (e.g. switch mode power supplies CPD range) The provides decoupling of two power supply units and ensures automatic redundant power supply
More informationQF(26) - Series Miniature Circuit Breakers - High Rating ( A)
1 pole 2 pole 3 pole 3+N Features AC Circuit Breaker Hydraulic-Magnetic technology % rating capability, independent of ambient temperature One, two, three pole, 1+N and 3+N (VDE) VC 8036 compliant (SANS
More informationEaton DC Power Solutions
Eaton DC Power Solutions 19 sub-rack Modular 3U and 6U options Up to 6 rectifier modules Pre-configured software High power density (24/48V: 300/250A, 6U, 19 ) Multiple AC option (1Ø, 3Ø, 2Ø) Fast on-line
More informationVoltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationSafety Light Grid Orion2 Extended
Safety Light Grid Orion Extended Orion Extended is a compact light grid for access protection in muting applications. The light grid has -4 beams and is intended for body detection. Cost effective solution
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET WirelessHART components Gateway and accessories 2 Measurement made easy The ABB offering on WirelessHART accessories connect wireless sensors to the automation
More informationUser Guide. Control Box. RoscoLED TM.
RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260
More informationUL 489 Cable-In / Cable-Out Branch Circuit Breaker
Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up
More informationElectronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationDigital Indicator DS 48/24 E
Data Sheet 10/33-2.04-EN Digital Indicator DS 48/24 E The indicator is suitable for measuring direct voltage or direct current. The units are installed in a rugged plastic housing and can be integrated
More informationFeatures. LED Driver. RCOB Constant Current Active PFC Single Output. AC/DC Converter
Features LED Driver Low Cost 230VAC LED Supply 350mA to 1050mA Output, 25-44VDC Active Factor Correction >0.95 Designed to drive 15W-46W COB LEDs Terminal Block Input/Output with Cable Clamps Fully Protected
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationXCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland
Characteristics limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening
More information////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)
////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationRTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values
CT/VT Interface 560CVT10 The fault current is measured up to 20 times nominal current. Therefore the current inputs withstand 50 times nominal current for 1 s. The CT/VT interface is equipped with one
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A
Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 0.6 A Complementary Input voltage limits Network frequency Inrush current Main Range of product Product or component type Power supply
More informationApplying branch circuit breakers and supplementary protectors in North America
Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North
More informationABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A
Product datasheet Characteristics ABL8RPS24100 regulated SMPS - 1 or 2-phase - 100..500 V - 24 V - 10 A Complementary Input voltage limits Network frequency Inrush current Cos phi Main Range of product
More information2600T Series Pressure Transmitters How to replace Profibus PA pressure transmitters with the 266 PA
Technical Information TI/266PB-EN 2600T Series Pressure Transmitters How to replace Profibus PA pressure transmitters with the 266 PA Pressure Measurement Engineered solutions for all applications 2600T
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More informationXCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11
Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11 Complementary Switch actuation Electrical connection Cable entry Contacts insulation form Positive opening
More informationWhite paper. Orion safety light guards Reduce complexity and save time
White paper Orion safety light guards Reduce complexity and save time The Orion series A complete range of safety light curtains and light grids Orion1 The Orion1 light curtains are used for finger or
More informationOvervoltage Protection
Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential
More informationMotor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)
More informationXCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20
Characteristics limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening
More informationMBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit
MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch
More informationHow to connect ABB Ethernet inverters with VSN700 Data Logger over Ethernet
ABB SOLAR INVERTERS How to connect ABB Ethernet inverters with Data Logger over Ethernet Basic information -05 Data Logger is a monitoring device developed by ABB. -05 Data Logger can be used to monitor
More informationControl Circuit and Load Protection Products
Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United
More informationXCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT
Characteristics limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive
More information