WR1000 SERIES. Thermal Arraycorders. Color. Large-capacity. High-speed

Size: px
Start display at page:

Download "WR1000 SERIES. Thermal Arraycorders. Color. Large-capacity. High-speed"

Transcription

1 WR1000 SERIES Thermal Arraycorders Color Hard disk for 40 minutes of continuous data capture Large-capacity High-speed A high-performance recorder which gives you the freedom to add only the functions you require for your own specific measurement applications. The WR1000 for Data Signal Input, onitoring, Recording, and Data Capture.

2 The Ultimate easurement Tool Create your own application-specific machine one that s perfect for your own recording needs simply by adding on as many modular units as you need to the main unit. Easy-toread color display, high-speed recording, large-capacity data capture all the features you need for specialized measurement applications. onitor Streamlined 10.4-inch TFT color display for easy confirmation of menu settings and captured data Input Choice of 8, 16, 24, or 32 channel models Plug-in lifiers for channels 1 through 16 (2 channels per unit) Selection of eight lifier types available High-resolution 12-bit and 16-bit A/D conversion* Wide voltage range from 20 m to 500* * aries with the type of lifier Graphtec offers a range of add-on units for you to choose from a sound card which lets you record and search through voice data to confirm measurement conditions, a 100-m length Z-fold chart unit, a 20-m Z-fold chart unit which fits inside the main unit, an annotation tray which facilitates the writing of comments directly onto the chart, and DC drive units. Recording High speed Chart speeds up to 200 mm/s* Long-term 100-m length Z-fold chart * 25 mm/s maximum when 24 or 32 channels are used Sound Sound card unit m Z-fold chart unit* Annotation tray Automobile Industry DC DC drive* m Z-fold chart unit * aximum chart speed is 25 mm/s Add-on Units Collision Testing Unit Configuration Exle DC B SCSI erits to the User The 8 GB hard disk drive lets you directly capture a large amount of data at a high-speed sling rate, ensuring that you capture the valuable data at the time of the collision itself. The WR1000 can both capture large amounts of data and record it onto chart paper, eliminating the need for a separate data recorder and chart recorder. The measured data can be converted into TEXT format, enabling you to use commercially available software for data analysis and report creation. Bench Test Unit Configuration Exle F/ Lo SCSI Sound erits to the User With the WR1000 s large-capacity hard disk drive, you can capture data right from the start of measurement, not just from when an irregularity occurs. This means that you can see the trend up to when the irregularity occurred. And, if you want to check the data where the irregularity occurred, you can quickly and easily play back the data stored in memory by using the Level search function. The measured data can be converted into TEXT format, enabling you to make use of commercially available software for data analysis and report creation. Running Test Unit Configuration Exle FFT DC B Remote Sound DC 20 erits to the User Event marks are captured into memory at the same time as data is being recorded, thereby facilitating a search of the data using the event mark search function after measurement has been completed. The variety of s offered enables you to input signals directly through sensors, thus eliminating the need for a transducer. The 20-m Z-fold chart unit lets you use easy-to-store Z-fold charts even for in-vehicle testing.

3 Thermal Arraycorders Amplifier units are essential for capturing measurement phenomena. Channels 1-16 accept a range of plug-in lifier units, giving you the versatility to select and install different types to suit your measurement application. FFT DC B oltage FFT measurement DC strain Amp Units ulti-input F/ Frequency to voltage conversion Lo Logic measurement* H Z High voltage/rs Zero suppression * Dedicated slot; cannot be used for other lifier types Hard disk for 40 minutes of continuous data capture Data Capture ain Unit Data Storage Units 8 GB hard disk, 640 B OD, or FDD for data capture RS-232C, plus a GP-IB or SCSI interface 256 kwords/ch internal memory; upgradable to 512 kwords/ch 20 µs high-speed data capture* Several data search functions * 8-channel model, when is installed You need long-term, large-capacity data capture capability. Select from four different types of data storage units. You can also select several different methods to search through your data for the section you need. 512k memory 8 GB hard disk drive 512 kwords/ch internal memory Interface Units 3.5" OD 3.5" FDD 3.5" magneto-optic disk drive 3.5" floppy disk drive Select from four interface units to process and analyze your captured data. You can also use an interface to facilitate computer control of various measurement functions. RS- 232C RS-232C SCSI SCSI GP- IB GP-IB Remote Remote Power Companies Railways edical Research Turbine Inspection & aintenance Unit Configuration Exle H Lo erits to the User The zone and scale conversion functions enable you to overlap waveforms so that you can see at a glance whether there are any irregularities. The 8 GB hard disk has the same capabilities as a conventional data recorder and enables you to play back data quickly and easily. The 200 mm/s chart speed enables you to check the data in real time, right there on the spot. Running Tests on Rolling Stock F/ Unit Configuration Exle RS- 232C SCSI Sound 100 erits to the User The 8 GB hard disk enables you to perform long-term measurement. Furthermore, when you want to record the data onto chart paper, the long-length Z-fold chart unit lets you record up to 100 meters of data. Inputting event signals for the sections of data that you need for later analysis facilitates data playback by letting you see the data directly after each signal. The wide range of s lets you measure voltage, temperature, rpms, vibrations and logic signals with just one WR1000 unit. Animal Testing Unit Configuration Exle FFT SCSI Sound 20 erits to the User The measured data can be converted into TEXT or CS format, enabling you to make use of commercially available software for data analysis and report creation. The zone and scale conversion functions (engineering units) enable you to make recordings with parameters such as position, scale width and unit specified as needed. You can add annotation as required to each channel The 100-m Z-fold chart unit enables you to record and store large amounts of data in an easy-to-store format.

4 Hard disk for 40 minutes of continuous data capture Data Capture A range of memory devices is provided for data capture select the 8 GB hard disk drive, the O disk drive, or the 512 kwords/channel internal memory to suit your recording applications. A choice of interfaces is also offered for computer control, data transmission, and data output. You can even use your WR1000 as a data recorder. Select your memory device to suit your required data capture time and sling speed Graphtec's large-capacity data storage devices enable you to measure data continuously, so that you don't lose any valuable data. 8 GB hard disk drive (Four 2 GB partitions): Continuous measurement for around 40 minutes at a 20 µs* 1 sling speed for 8 channels of data 512 kwords/ch internal memory: 1 µs* 2 sling speed enables the capture of high-speed events; data is captured on all channels in seconds 3.5" magneto-optic disk drive: Captures data for 8 channels at a maximum 500 µs* 3 sling speed; stores data captured on the hard disk or in internal memory (cannot be installed concurrently with the FDD) 3.5" floppy disk drive: Comes standard with the WR1000; is used to store short-term measurement data and setup parameters (cannot be installed concurrently with the O drive) *1 100 µs maximum when 24 or 32 channels are used *2 aries with the type of installed *3 2 ms maximum when 24 or 32 channels are used Capturing data to an 8 GB hard disk Sling speed: 20 µs (max.) No. of measurement channels : 8 Data capture of around 40 minutes of continuous measurement Now you can perform long-term, continuous measurement and capture of data and eliminate the possibility of errors that may be caused by analyzing several short-term blocks. (2 GB is the maximum size of a data file) Car Engine Functions ibration Pressure RPs Temperature etc. 512 kwords/ch memory (built-in) 8 GB hard disk drive (built-in) RS-232C GP-IB WR1000 control Transmission of measurement data Computer O disk drive (built-in) SCSI Output of measurement data (TEXT format) External hard disk, O or ZIP drive, PCCIA media easurement Data Capture Times Data capture unit 256 kwords/ch memory 512 kwords/ch memory Hard disk (2 GB) O disk (640 B) 1µs 0.256s 0.512s 10µs 2.56s 5.12s 20µs 5.12s 10.24s 41.6min Powerful search functions enable you to find the data you need quickly and easily When you have captured a huge amount of data, you can use our various search functions to quickly locate the data you need to look at. Date & time search: Searches your data from the specified date and time Level search: Specifies the search level (voltage) then searches for data above or below Event search: Searches for event data input during measurement Skip search: Searches while sending data at a fixed amount Sound marker search: Searches through voice data recorded during measurement Exle Event signal easurement level 100% easurement level 75% easurement level 50% Selection of interfaces for computer-based measurement You can configure your system for computer control of your WR1000, and for data transmission. You can also select a file format to enable easy reading of data captured and stored on external data storage devices. SCSI Interface: Converts the measurement data into TEXT format so that it can be read by your hard disk, O or Zip drive, or PCCIA media. (Use a hard disk or SCSI interface recommended by Graphtec. Graphtec does not, however, provide support for the connection between the hard disk and your computer.) RS-232C or GP-IB Interface: When connected to your PC, this interface is used to control the WR1000 and for the transmission of measurement data. The RS-232C interface comes standard with the WR1000. Remote Interface: Controls the WR1000 using TTL level signals. Note: The SCSI and GPIB interfaces cannot be concurrently installed 100µs 25.6s 51.2s 3.4h Sling speed 500µs 2.1min 4.2min 17.3h 5.5h 1ms 4.2min 8.5min 1.4 days 11.1h Date & time search: January 20, 2000, 15:30:52(hh:mm:ss) Level search: 75% Event search Skip search: 20 s easurement date: January 20, 2000 easurement time: 15:30:10 (hh:mm:ss) Event search points Skip search point Level search points 10ms 42.6min 1.4h 14 days 4.6 days (when measuring on 8 channels) 100ms 7.1h 14.2h 144 days 46 days 1s 2.9 days 5.9 days 1,446 days 462 days 5s 14 days 29 days 7,233 days 2,314 days Date & time search point 15:30:52 easurement level 0% Number of measured points [s] Sound marker Start of measurement Fast oscillation 10 seconds Lowest value 20 seconds Peak 30 seconds Gradual fall 40 seconds End of measurement [ ] Comments in brackets are exles of captured voice data

5 Dedicated keys and simple menu for easy operability Dedicated control panel keys are provided for your basic setups. The WR1000 keys have an analog look and feel, and enable you to make your interactive menu settings quickly and easily. Amp setting keys for each channel Character input keys Chart speed keys - the speed can be changed even during recording Input Thermal Arraycorders The maximum number of input channels is 32. Channels 1 through 16 use plug-in s select from a wide range to suit your application. In addition, dedicated keys such as those you find on a conventional analog recorder are provided for settings simple and easy. enu keys enu setup keys to change and register your settings Large-format color display for detailed data presentation and convenient calculations Scaling function: This function lets you change the value and unit of the measurement signal so that you can directly read the physical value of the measured object. Input signal 0 to 5 Setting exle After scaling 5 to 25kg onitoring The large-format 10.4-inch color TFT screen enables you to display measured data in waveform and level formats in full color. Input values, as well as the EAS., RANGE, POSITION, and FILTER settings for each channel can also be confirmed at a glance. Furthermore, performing calculations on the input signals enables you to understand the measurement conditions more easily. Level display of input signals Snapshot function press the Copy key to enable a 2-screen comparison of a static waveform with the realtime waveform Digital display of input signals The fastest chart speed among recorders in its class, plus many other innovative functions The WR1000 features a 200 mm/s* 1 chart speed, 8 dots/mm resolution for crisp, clear traces, and a user-specifiable chart recording format that lets you choose your own waveform recording start points and channel widths for even more flexibility. Default fixed formats User format CH.3 60mm 100-m Z-fold chart unit Recording Waveforms are recorded at speeds up to a fast 200 mm/s* 1, enabling realtime capture of fast-moving events. The 100-m length Z-fold chart enables long-term recording. The recording zones and spans can be set individually for each channel. *1 25 mm/s when 24 or 32 channels are used, and/or when a DC drive is used CH.4 200mm 20-m Z-fold chart holder unit CH.2 40mm CH.1 20mm Annotation tray for the writing of comments during measurement

6 Unit Configuration Unit type Unit name Part number Description ain Unit* 1 8-ch main unit WR Channels 1-8: plug-in s (maximum 4 slots) 16-ch main unit WR Channels 1-16: plug-in s (maximum 8 slots) 24-ch main unit WR Channels 1-16: plug-in s (maximum 8 slots) Channels 17-24: Dedicated 8-ch unit for voltage measurement 32-ch main unit WR Channels 1-16: plug-in s (maximum 8 slots) Channels 17-32: Two dedicated 8- ch units for voltage measurement Amp Units oltage ulti-input High-voltage/RS H/RS FFT FFT Frequency to voltage F/ conversion Zero suppression Z DC B strain DC B Logic Lo 16 channels/unit Data Storage Additional memory for 8-/16- B-389 User-specifiable; enables memory Units* 1 channel models to be increased from 256 kwords/ch to 512 kwords/ch Additional memory for 24- B-390 User-specifiable; enables memory channel models to be increased from 256 kwords/ch to 512 kwords/ch * 1 ust be specified at time of initial order for the main unit * 2 When the 8 GB hard disk drive and O drive are both installed, only one SCSI interface card is supplied Unit type Unit name Part number Description Additional memory for 32- B-391 User-specifiable; enables memory channel models to be increased from 256 kwords/ch to 512 kwords/ch 8 GB hard disk drive B-385 User-specifiable; comes with SCSI interface* 2 3.5" FDD Comes standard with main unit 3.5" OD B-384 User-specifiable; comes with SCSI interface* 2 ; replaces FDD Interface Units RS-232C Comes standard with the main unit GP-IB B-387 User-specifiable; cannot be installed concurrently with the SCSI interface SCSI B-386* 1 User-specifiable; cannot be installed concurrently with the GP- IB interface Remote interface Comes standard with main unit Sound Card Sound card unit B-388 Captures voice data onto the hard Unit* 1 disk; B-385 must be installed DC Drive* 1 DC drive for 8-/16-ch models B DC DC drive for 24-ch models B DC DC drive for 32-ch models B DC DC drive for 8-/16-ch models B DC DC drive for 24-ch models B DC DC drive for 32-ch models B DC Other Units 100-m length Z-fold chart unit B-392 Is mounted under the main unit 20-m length Z-fold chart unit B-405 Fits into the roll paper slot; enables use of 20-m lengths of Z-fold chart paper Annotation tray B-393 Enables the user to write comments directly onto the chart Specifications WR WR WR WR Basic specifications Analog input (max.) No. of slots : 4 No. of slots : 8 Ch 1 to 16: Ch 1 to 16: 2 ch/unit 2 ch/unit 8 slots; 2 ch/unit 8 slots; 2 ch/unit Ch 17 to 24: Ch 17 to 32: one 8-ch voltage unit two 8-ch voltage units Logic input No. of slots: 1; 16 ch/unit Interfaces RS232C; remote control (Start/Stop, Trigger in/out, EXT. Feed, /C Alarm) emory capacity 256 kwords/ch (memory expandable up to 512 kwords/ch) Data storage unit 3.5" FDD comes standard (for the storage of setup parameters and captured data) Display screen 10.4" TFT color display (640 x 480 dots) Recording method Thermal dot array (8 dots/mm) Chart paper Roll paper (PR231A, 210 mm width x 40 m length), black trace Operating environment 0 to 40ºC, 30 to 80% RH (5 to 35ºC when using printer) Power rating 100 to 120, 200 to 240 AC(automatically selected) 50/60Hz Power consumption Approx. 360 A Approx. 400 A Approx. 440 A Approx. 480 A External dimensions Approx. 405 x 336 x 140 mm* 3 Approx. Approx. (W) x (D) x (H) mm 405 x 336 x 180 mm* x 336 x 220mm* 3 Weight Approx. 9 kg* 4 Approx kg* 5 Approx. 13 kg* 5 Approx. 15 kg* 5 Recorder functions easurement conditions Realtime recording (data is directly recorded onto chart paper only) Realtime recording & data capture (data is directly recorded onto chart paper and simultaneously captured to a memory device) Data capture (data is captured to a memory device only) Waveform display Display format: Y-T, X-Y; measurement data of 8 channels Signal recording litude aximum 200 mm (1600 dots) Recording formats 200 mm x 1, 160 mm x 1, 100 mm x 1, 100 mm x 2, 80 mm x 2, 50 mm x 2, 50 mm x 4, 40 mm x 4, 25 mm x 8, 20 mm x 8, (12.5 mm x 16, 10 mm x 16), Zone Figures in ( ) refer to the 16-, 24-, and 32-channel models only Chart speeds 1, 2, 5, 10, 20, 50, 100, 200 mm/s, mm/min, mm/h, 1, 2 (user-settable chart speeds)* 6, External clock Recording accuracy Y : ±0.3% ±1 dot, T : ±2% ±0.5 mm Data capture Data being recorded onto chart paper can be simultaneously written to internal memory or to a memory device (, O) Annotation System annotation, channel annotation (10 to 64 characters) Specifiable printing interval 10 to 100 cm in 10-cm steps Logging function easurement conditions easured data display easurement/display/ recording interval Realtime recording (data is directly recorded onto chart paper only) Realtime recording & data capture (data is directly recorded onto chart paper and simultaneously captured to a memory device) Data capture (data is captured to a memory device only) easured data of any channel can be displayed as digital values using a screen split into 2, 4, 8, or (16) parts Figures in ( ) refer to the 16-ch model only 1 to 3600 seconds (in 1-s steps) WR WR WR WR Logging function Recording formats Day/month/year, measurement interval, hh:mm:ss, channel-specific measured data, minimum, maximum, and mean values Data transfer Output of ASCII data via the RS-232C or GP-IB interface (Data can be recorded on chart paper simultaneously) emory functions Sling speeds (1), (2), 4, 8, 10, 20, 40, 80, 100, 200, 400, 500, 800 µs 1, 2, 4, 8, 10, 20, 40, 80, 100, 200, 400, 500, 800 ms, 1, 2, 4, 5 s, EXT. clock (The sling speeds differ according to the type of installed) emory banks (Block) 1, 2, 4, 8, 16, 32, 64 or 128 blocks emory coupling (Expand) 8 ch x 1, 4 ch x 2, 2 ch x 4, 1 ch x 8 Waveform scaling Time axis 1/10, 1/8, 1/5, 1/4, 1/2, 1, 2, 4, 5, 8, 10 Cursor function Cursor readout, scroll and zoom Trigger functions Trigger source Start function: Internal, External, anual, Off Stop function: Internal, External, anual, Time, Off Trigger type Edge, Level, Count, Slope (d/dt), Filter Trigger slope Rising, Falling, Low, High Trigger level -100 to +100% (1% steps) and values set within ±FS of the specified range Pretrigger 0 to +100% in 1% steps Trigger function Record, emory Trigger action Single, Repeat Trigger gate OFF, relative time, absolute time Logic trigger Specifiable patterns: H (high), L (low), X (don't care) Calculation functions Scale value conversion The scale values and units are set with respect to the upper and lower limits of the desired measurement area Statistical calculation Area (Y-T, X-Y), AX, IN, P-P, Average, RS, standard deviation, rise time and fall time Specifiable range Range defined by cursors and the range (area) defined by cursors or waveforms Programmable calculations No. of terms: 32 maximum (operands, variables, constants, and functions) Operands: +, -, x, /, ( ) ariables: channel-specific data Constants: Number: 32 maximum Functions: SQR, LOG, EXP, ABS, DIF, DDIF, INT, DINT, SIN, COS, TAN, ASIN, ACOS, ATAN, EAN, DLY Waveform judgement Judgment area definition: Define the area by moving to the top, bottom, and both sides of the displayed waveform Judgement: GO (within area), NO GO (outside area) * 3 Excluding rubber feet and protuberances * 4 When 4 s are installed * 5 When 8 s are installed * 6 25 mm/s maximum when 24 or 32 channels are used

7 Plug-in lifier units (oltage input) easurement range Floating ground with unbalanced-load input (each channel is independent ) 50 m to 500/FS Sling speed: 4 µs max.; Resolution: 12 bits DC to 50 khz (+1/-3 db Typ.) 1.5, 5, 10, 30, 50, 500 Hz, 5 khz (ulti-input) easurement range Floating ground with unbalanced-load input (each channel is independent) oltage: 20 m to 500/FS, Thermocouples: K, J, T, R, E, B Sling speed: 10 µs max; Resolution: 16 bits DC to 20 khz (+1/-3 db Typ.) 1.5, 5, 10, 30, 50, 500 Hz, 5 khz H H (High-voltage/RS) easurement range ax. permissible Floating ground with unbalanced load input; each channel is independent; safety sockets for 2 terminals oltage: 20 to 1000 /FS; RS: 10 to 500 rms Sling speed: 10 µs; resolution: 16 bits DC to 2 khz (+1/-3 db typ) Between + and - terminals: 1000 DC (DC + AC p-p) Floating: 350 ACrms 1.5, 5, 10, 30, 50, 100, 500 Hz Z Z (Zero suppression) Floating ground with unbalanced load input; each channel is independent; safety sockets for 2 terminals easurement range 50 m to 200 /FS Suppression voltage 50 m to 2 range: ±10, 5 to 200 range: ±100 Sling speed: 10 µs; resolution: 16 bits DC to 10 khz (+1/-3 db typ) ax. permissible Between + and - terminals: 500 DC (30 DC for ranges less than 2 ) Floating: 250 ACrms 1.5, 5, 10, 30, 50, 500 Hz, 5 khz F/ F/ (Frequency-to-voltage conversion) ax. permissible Floating ground with unbalanced load input; each channel is independent; BNC jack 200 Hz to 40 khz Sling speed: 4 µs; resolution: 12 bits Between + and - terminals: 60 DC (DC + AC p-p) Floating: 30 ACrms 0.5, 30, 50, 100, 500 Hz, 1, 5 khz DC B DC B (DC strain) easurement range Bridge voltage ax. permissible Floating ground with unbalanced load input; each channel is independent; 7-pin 4-line round connectors 200 to x 10-6 strain/fs 2, 4 DC Sling speed: 10 µs; resolution: 16 bits DC to 20 khz (+1/-3 db typ) Differential input: 10 DC (DC + AC p-p) Common mode voltage: 10 ACrms 1.5, 10, 30, 100, 300 Hz, 1 khz FFT FFT (FFT measurement) easurement range ax. permissible Floating ground with unbalanced load input; each channel is independent; BNC jack 50 m to 50 /FS Sling speed: 1 µs: resolution: 12 bits DC to 250 khz (+1/-3 db typ) Between + and - terminals: 60 DC (DC + AC p-p) Floating: 30 ACrms 1.5, 5, 50, 500 Hz, 5, 50, 100 khz, anti-aliasing filter LO LO (Logic) 16 (4 per terminal x 4) Input voltage range 0 to +25 max (Single-ended ground) Threshold levels TTL (+1.4 ), COS (+2.5 ), Contact point (+5.0 ) Sling speed 1 µs maximum Note: The logic has its own dedicated slot, and cannot be replaced with another type of. Hard disk drive unit Data capture Sling speed File capacity Total data capacity File data search functions Set-up parameters, measurement data 20 µs to 5 s (8-channel model) ; sling speed depends on the type and number of s installed Up to 2 GB (1 Gword) Four 2 GB files (four 1-Gword files) Specified date and time, level, event, skip 512k memory emory expansion unit Expansion memory 256 kwords/ch; enables expansion up to 512 kwords/ch 3.5" OD 3.5" OD unit Installation Data capture Sling speed File capacity File data search functions GP- IB GP-IB interface unit Interface SCSI Interface SCSI interface unit Replaces the floppy disk drive unit Set-up parameters, measurement data 500 µs to 5 s (8-channel model) ; sling speed depends on the type and number of s installed 640 B maximum Specified date and time, level, event, skip Cannot be used concurrently with the SCSI interface SCSI-3 (wide) ; cannot be used concurrently with the GP-IB interface Sound Sound card unit oice capture function Captures voice data onto the hard disk oice replay function Replays voice data continuously from the specified position; measurement data is displayed from the position where replay was stopped icrophone input terminal One (400 to 500Ω) * The hard disk drive unit (B-385) must be installed before the sound card can be used DC DC drive unit Input voltage range Power consumption aximum chart speed 12 type: 10 to 16 DC 24 type: 21 to 32 DC (specify either 12 or 24 type) 8-ch and 16-ch models: maximum 190 A; 24-ch model: maximum 228 A; 32-ch model: maximum 264 A 25 mm/s

8 RS-232C REOTE DC-LINE 12 DC-POWER DC-FUSE! POWER AC-LINE / C105* Probe for Floating oltage Input Application Checking relay coil voltage or the operational timing of voltage ON/OFF from the control panel unit No. of inputs 4 channels (floating for each channel) Input range High, Low Input resistance High: approx. 100 kω Low: approx. 50 kω Detectable voltages High: 100 to 250 AC, 80 to 250 DC Low: 50 to 150 AC, 20 to 150 DC Non-detectable voltages High: 0 to 20 AC, 0 to 29 DC Low: 0 to 10 AC, 0 to 15 DC Response times High: within 1 ms, Low: within 3 ms aximum floating voltage 250 DC, ACp-p * Logic measurement required Cables and cords Name Part number Remarks Set of 2 input cables B pin banana-plug cables, bare tips Set of 4 input cables B pin banana-plug cables, bare tips Set of 8 input cables B pin banana-plug cables, bare tips Set of 16 input cables B pin banana-plug cables, bare tips BNC-BNC cable RIC m, BNC plug-bnc plug required BNC-banana clip cable RIC m BNC-alligator clip cable RIC m AC power cord RSC pin plugs with grounding conductor DC power cord RIC m cord with round 10 pin connectors Cl adapters, meters, and probes Name Part number Remarks Cl adapter C-102 easures AC 0 to 1200 A Digital cl meter C-111 easures AC/DC current (0 to 2000 A), AC/DC voltage (0 to 1000 ), resistance (0 to 4000 kω), frequency (10 to 4000 Hz), and temperature (-50 to +160 ) Temperature probe for cl meter RIC to +200 C; for use with C-111 Line separator C-108 x1, x10; for use with C-111 Logic IC cable RIC-07 To connect RIC 08/09 with logic Alligator-clip cable RIC-08 For use with logic IC-clip cable RIC-09 For use with logic Probe set RIC-10 One each of RIC-07, -08, -09 Floating voltage input probe C-105 For use with logic oltage fluctuation probe C-106 For use with logic Accessories C106* Probe for oltage Fluctuations Application Detecting of momentary voltage drops of industrial power lines and waveform recording of those drops No. of inputs 1 Input resistance 10 kω Input range 100 AC/120 AC Frequency range Both 50 Hz/60 Hz oltage fluctuation detection level ±10%/±20% Trigger output Ch 1: detected at +10%, +20% Ch 2: detected at - 10%, - 20% Detection method Full-wave rectification, peak value detection Response times Approx. 1 cycle of the input AC voltage ax. allowable 160 rms * Logic measurement required Other Name Part number Remarks Remote connector RCN pin connector jack BNC conversion plugs SA101-4P Banana to BNC, 4 per set Safety BNC adapter SA-102 For use with high-voltage BNC to banana conversion adapter Supplies Name Part number inimum sales unit Remarks Thermal roll paper PR231A 10 rolls 40 m/roll Thermal Z-fold paper PZ231A 5 packs 100 m/pack (for 100-m Z-fold chart unit) Thermal Z-fold paper PZ packs 20 m/pack (for 20-m Z-fold chart unit) Head cleaner set B kit Contains cleaning liquid and sheets Dimensional Diagram TRACE CONTRAST Tolerance: ±5 mm Unit: mm * B-331 C-105 C-106 RIC-08 RIC-09 RIC-10 RIC-07 RIC-110 C-108 C-102 SA-102 RCN-114 C ch model: One 8-channel unit is mounted under the main unit * 36-ch model: Two 8-channel units are mounted under the main unit Note: The above diagram includes several, but not all, user-specifiable add-on units RIC-140 RSC-110 To ensure correct and safe use of your recorder: Read your User's anual before using the recorder, and operate it correctly in accordance with the procedures described. To prevent malfunctions or electrical shock due to current leakage, ensure that the recorder has a good protective ground, and ensure that the supply voltage conforms to the recorder's power rating. Brand names and product names listed in this brochure are the trademarks or registered trademarks of their respective owners. Specifications are subject to change without notice Shinano-cho, Totsuka-ku, Yokohama , Japan Tel : +81 (045) Fax : +81 (045) info@graphteccorp.com Web : RWR SU Printed in Japan

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope 3100 Application-specific Portable Data Capture Systems built on the 3100 Data Platform PC Measurement Digital Oscilloscope PC-based Data Logger Data Recorder & Logger Made Easy! Style! Fast & Furious

More information

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) FALCON Models TA220-1000 Series DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels The

More information

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling TML Pam E-442B SMART DYNAMIC STRAIN RECORDER Standard With analog output DC-204R DC-204Ra Strain DC voltage Temperature High speed sampling 200kHz Large data recording 2GB capacity Automatic data storing

More information

Practical and Compact!

Practical and Compact! Practical and Compact! 4ch Data Recorder 8ch Data Recorder Practical and Compact! Direct connection of Sound and Vibration Sensors 50 mm 210 mm 270 mm 8ch Data Recorder Sensitivity calibration of microphones

More information

WR300 THERMAL ARRAYCORDER USER S MANUAL MANUAL NO. WR300-UM-152

WR300 THERMAL ARRAYCORDER USER S MANUAL MANUAL NO. WR300-UM-152 WR300 THERMAL ARRAYCORDER USER S MANUAL MANUAL NO. WR300-UM-152 Introduction Introduction Thank you for purchasing a WR300 Series Thermal Arraycorder. Please read this manual thoroughly before attempting

More information

Continuous Measurement up to 43 MS/s

Continuous Measurement up to 43 MS/s Continuous Measurement up to 43 MS/s Time Interval Analyzer Maximum continuous sampling rate 43 Ms/s Maximum sampling size 0 9 data samples 25 ps measurement resolution 00 ps internal jitter Built-in printer

More information

CF-4210Z/4220Z. Personal FFT Analyzers

CF-4210Z/4220Z. Personal FFT Analyzers Personal FFT Analyzers The jog/shuttle cursor, a wheel that combines the functions of a rotary knob and a shuttle cursor, provides easy menu window setup operation. The FFT analyzers can be used as OK/NG

More information

Expanding the Basic GL7000 Configuration

Expanding the Basic GL7000 Configuration Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Expanding the Basic GL7000 Configuration The GL7000 is a modular system that allows you to add analog

More information

Specifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T

Specifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T 3-57 Universal Recorder -2H Improved real-time processing function with high-speed DSP Incorporated real-time digital filter 8th digital filter enables to acquire clear waveform. High-speed/low-speed dual

More information

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS 3-77 Sensor Interface 3-77 PCD-400A Carrier Wave Type Compact and Moderate Prices Easy sensor connection using various types of input adapters Connects to PC using USB interface Measurement using 1 unit

More information

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151 USER S MANUAL Contents 1. Main Features... 4 A Variety of Display Formats...4 Simple and Easy to Use...5 Thumbnail Waveform Display...5 Export to Direct Excel File Function...6 CSV File Batch Conversion...6

More information

Sefram SEFRAM DAS 20/DAS 40. Sefram

Sefram SEFRAM DAS 20/DAS 40. Sefram Make sure to visit our Website http://www.sefram.fr Sefram Sefram SEFRAM DAS 20/DAS 40 2 to 4 analogue channels Universal input DC, AC+DC RMS voltage measurement Frequency, Thermocouple Power analysis

More information

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL220 midi Logger Built-in 4.3" WQVGA TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor

More information

3156 LEAK CURRENT HiTESTER

3156 LEAK CURRENT HiTESTER 2003 3156 LEAK CURRENT HiTESTER Safety Standards Measuring Instruments The Long-Awaited Bench-type Model Is Here! Leakage Current Measurement Essential for Electrical Safety Because of the risks it poses,

More information

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour. GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and

More information

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility.

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility. C-DR091/161 SERIES DIGITAL VIDEO RECORDER NTSC TOA's Digital Recorder series combine high reliability with all the advantages of scalable expansion flexibility. Operated with a us the DVR Series makes

More information

Circuit Breaker Analyzer & Timer CAT31

Circuit Breaker Analyzer & Timer CAT31 Simple & easy to operate 3 timing channels for main and resistive contacts 3 timing channels for auxiliary inputs Open & Close coils current measurement Resistance measurement of pre-insertion resistors

More information

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise! Overview NEW dual ADC Overview Let`s get! The new hardware generation makes your measurement more precise! Dual core Input from Dewesoft This new technology solves the often faced problem that the signal

More information

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT66 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT65 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels 4 additional analog

More information

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System 3-51 EDX-10 Series Compact Recording System Compact & lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls

More information

Introduction. Chapter 2

Introduction. Chapter 2 The Vantage PRO unit (Figure 2-1) combines a digital and graphing multimeter, lab scope and ignition scope with a powerful diagnostic database. Figure 2-1 Vantage PRO This diagnostic database gives you

More information

Data Platform GL7000

Data Platform GL7000 Data Platform GL7000 Datasheet GL7000 Modular Data Platform Measurement ranges: ±20 mv... ±100 V, thermocouples, Pt100, JPt100, Pt1000, humidity, strain gauge, vibration sensors Measurement channels: up

More information

6220 Ethernet-Based Voltage Measurement Module

6220 Ethernet-Based Voltage Measurement Module 6220 Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100-kHz per channel sample rate ±10V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger

More information

IST ULTRASTAB Power Supply for high precision transducers

IST ULTRASTAB Power Supply for high precision transducers IST ULTRASTAB Power Supply for high precision transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±0 V voltage output (see

More information

EDX-10 Series. Compact Recording System

EDX-10 Series. Compact Recording System 3-49 EDX-10 Series Compact Recording System Compact, lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls

More information

Integrated Recorder GX-1

Integrated Recorder GX-1 Everybody's problem: Accelerated product development. Our goal: Decreasing the period between data acquisition and data analysis. Our solution: For data recording systems, the. Fast Collection of Valuable

More information

6220 Ethernet-Based Voltage Measurement Module

6220 Ethernet-Based Voltage Measurement Module Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100 khz per channel sample rate ±10 V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger modes

More information

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage

More information

Digital Storage Oscilloscope

Digital Storage Oscilloscope GDS-800 Series Digital Storage Oscilloscope GDS-800 Series at 60MHz/100MHz/150MHz/250MHz bandwidth with or chrome LCD display, are designed and built to meet the demands of a modern Digital Storage Oscilloscope

More information

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Wide Bandwidth Strain Gage Input 3B18 FEATURES Wideband (20 khz) single-channel signal conditioning module. Module Bandwidth is user-selectable between 20 khz and 100Hz, with user-supplied filter caps

More information

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851 midi LOGGER HV GL2000 Quick Start Guide 604929220 GL2000-UM-851 Thank you for choose the midi LOGGER HV GL2000. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in

More information

Student Quick Reference Guide

Student Quick Reference Guide Student Quick Reference Guide How to use this guide The Chart Student Quick Reference Guide is a resource for PowerLab systems in the classroom laboratory. The topics in this guide are arranged to help

More information

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL820 midi Logger Built-in 5.7" TFT LCD Color Display Stand-alone or PCconnected operation 20 Analog Channels Standard, Expandable to 200 Input-to-output and channel-to-channel Isolation USB and Ethernet

More information

6224 Ethernet-Based Strain Measurement Module

6224 Ethernet-Based Strain Measurement Module Ethernet-Based Strain Measurement Module Features 12 strain gage inputs 24-bit/delta-sigma ADC per channel 50-kHz per channel sample rate User programmable excitation Simultaneous sampling Remote sensing

More information

Three-Phase Power Quality Analyzer PowerPad Model 3945-B

Three-Phase Power Quality Analyzer PowerPad Model 3945-B Three-Phase Power Quality Analyzer PowerPad Model 3945-B Display and record waveforms, transients, trend data and events simultaneously! Wouldn t it be nice if you could look inside your electrical system

More information

User friendly and easy to program

User friendly and easy to program New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric

More information

Wireless Data Logger System

Wireless Data Logger System RTR-57U Wireless Data Logger System Collect, Manage and Monitor Your Valuable Data via Wireless Communication USB ion With sensor adaptor connected RS-232C ion to Computer to Network Image created for

More information

PORTABLE DATA ACQUISITION RECORDERS

PORTABLE DATA ACQUISITION RECORDERS PORTABLE DATA ACQUISITION RECORDERS FALCON II Series TA220-2300 ~ 16 Channels TA220-2800 ~ 32 Channels Falcon II - The Newest Generation Model TA220-2800 32- Channels Model TA220-2300 16-Channels www.solteccorp.com

More information

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers Power Supply for IT/ITN ULTRASTAB transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±10 V voltage output Six individual

More information

Relay Deck Datasheet

Relay Deck Datasheet Datasheet SA13731 General The provides a number of relays for user control. Its mechanical relays allow switching high power loads and its solid-state relays provide an alternative for lower-power loads.

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System The issue of security is more than ever important.

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

Compact Size Recorder with Color Display. New Concept with Detachable Printer. Enhanced Model with Harmonic Analysis Function...

Compact Size Recorder with Color Display. New Concept with Detachable Printer. Enhanced Model with Harmonic Analysis Function... 8807-01 8808-01 MEMORY HiCORDER Recorders New Concept with Detachable Printer * Photo shows the 8808-01 with optional printer unit installed. Compact Size Recorder with Color Display The 8807-01/8808-01

More information

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA. Ultrasonic Displacement Sensor. Ordering Information Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors

More information

Advancing AiHD Cloud Solution

Advancing AiHD Cloud Solution NEW Advancing AiHD Cloud Solution Ai Holdings Corporation (parent company to Graphtec) created the "" cloud system by consolidating resources from group companies to provide advanced IoT platform with

More information

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A... Electronics & Software CoMo Logic Single-Channel y(t) ControlMonitor Type 5875A... The CoMo Logic monitor has a graphics display and charge mode input for monitoring time-dependent measurands in production

More information

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Voltage Input 3B30 / 3B31 FEATURES Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage

More information

High-Speed Data Acquisition System

High-Speed Data Acquisition System High-Speed Data Acquisition System 1 Quick & Easy Setup Easiest Data Acquisition Systems on the Market The TMX features a high resolution, 17" touch screen display, as well as pre-defined set up options,

More information

midi LOGGER GL840 Quick Start Guide GL840-UM-850

midi LOGGER GL840 Quick Start Guide GL840-UM-850 midi LOGGER GL840 Quick Start Guide 604849020 GL840-UM-850 Thank you for choose the midi LOGGER GL840. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information

Advanced NI-DAQmx Programming Techniques with LabVIEW

Advanced NI-DAQmx Programming Techniques with LabVIEW Advanced NI-DAQmx Programming Techniques with LabVIEW Agenda Understanding Your Hardware Data Acquisition Systems Data Acquisition Device Subsystems Advanced Programming with NI-DAQmx Understanding Your

More information

Models PEL 102 & PEL 103

Models PEL 102 & PEL 103 V1 V2 V3 N 1000V CAT III I1 I2 I3 600V CAT IV POWER & ENERGY LOGGER ON/OFF START/STOP Special product features MEASURES '''' ''' D E M A N D $ TRACKS E N E R G Y C O S T POWER QUALITY ANALYZERS, METERS

More information

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.

More information

Product RS stock no. Mitsubishi no. Description and features Display FX-40DU-E LCD display and function keys directly connected into FX PLC

Product RS stock no. Mitsubishi no. Description and features Display FX-40DU-E LCD display and function keys directly connected into FX PLC Data Pack D Issued March 1997 232-6118 Data Sheet Man machine interface display Mitsubishi FX PLC Supplied to RS by Mitsubishi Electric (UK) Ltd This fully interactive man machine interface display is

More information

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use. PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER midi LOGGER GL820 Quick Start Guide GL820-UM-851 Thank you for choose the midi LOGGER GL820. This

More information

Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system Highly Integrated Voice Alarm & Public Address System Description The issue of security is more than ever

More information

System Interface Unit SIU-100/100T

System Interface Unit SIU-100/100T System Interface Unit /100T Since its introduction, the Digital Mixer has opened up an entirely new set of opportunities for affordable PA and sound-recording applications. Recognizing the ever-increasing

More information

TDS-630. High Performance Easy Handling

TDS-630. High Performance Easy Handling TDS-630 High Performance Easy Handling High Speed and High Functionality achieved by enhancing Measurement Speed and Processing Function Repeated Measurements in 0.1 seconds per 1000 channels TML-LINK

More information

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC. Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals

More information

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision New Low-Cost, High-Precision Power Quality, Energy & Environment Monitoring PQube 3 Power Quality Class A Energy Revenue Grade class 0.2s Accuracy Additional AC, DC, and Environment Sensor Channels World

More information

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances

More information

Time Inter val Analyzer

Time Inter val Analyzer Time Inter val Analyzer 2nd Edition Foreword Thank you for purchasing the YOKOGAWA TA520 Time Interval Analyzer. This User s Manual contains useful information about the precautions, functions, and operating

More information

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24 Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution DINALOG A 96 x 24 Programmable quasi-analogue

More information

895/896M Frequency Output Math Modules

895/896M Frequency Output Math Modules 895/896M Frequency Output Math Modules Application Example Both models are designed for integrator/totalizer applications. The 896M is ideal for demand metering applications. With one high speed pulse

More information

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

Electronic SUNSTAR & 传感与控制 Software   TEL: FAX: KiBox To Go Measurement and Ev Electronic SUNSTAR & 传感与控制 Software http://www.sensor-ic.com/ TEL:0755-83376549 KiBox To Go Measurement and Evaluation System for Combustion Analysis in Test Vehicles with KiBox Cockpit Software The KiBox

More information

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments

Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys. For innovation in magnetic measuring instruments Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration Surveys For innovation in magnetic measuring instruments Spectramag-6 Six-Channel Spectrum Analyser for Magnetic Field and Vibration

More information

E101 - Strain Gauge Transducer Display Module. Contents

E101 - Strain Gauge Transducer Display Module. Contents E101 - Strain Gauge Transducer Display Module Contents Torque Transducer Display Interface: TSE3249R Strain Gauge Transducer Display Interface [E101] Operating Guide: TSE2097V (Includes Introduction, Description

More information

LGR-5325 Specifications

LGR-5325 Specifications s Revision 1.0, April, 2010 Copyright 2010, Measurement Computing Corporation s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in italic text are

More information

Integrating Sound Level Meters LA-5570/5560/2560

Integrating Sound Level Meters LA-5570/5560/2560 Integrating Sound Level Meters LA-5570/5560/2560 High-functionality Integrating Sound Level Meters Type 1 Sound Level Meters High sensitivity Wide band LA-5570/5560 High-functionality Sound Level Meter

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC-1010.2-031 CAT I or CAT II, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual:

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

SCP for Plastics Processing

SCP for Plastics Processing Measure & Analyze MCS SCP for Plastics Processing Modules for Signal Conditioning System Type 2853A..., 2207A..., 5063A..., 5227A..., 5613A... The SCP is a modular system for conditioning measuring signals

More information

Attach up to 10 input/output modules in a mixed condition environment. Corresponds to various measurement types (physical, mechanical, and electrical)

Attach up to 10 input/output modules in a mixed condition environment. Corresponds to various measurement types (physical, mechanical, and electrical) General Purpose Data Acquisition System Modular Data Acquisition PLATFORM DATA PLATFORM GL7000 Next Generation Data Acquisition Unit with Touch Panel Control On-Demand Signal Acquisition Embedded Monitoring

More information

CONTENTS 1. SAFETY INFORMATION SPECIFICATION PARTS & CONTROLS General Specification Electrical Specification...

CONTENTS 1. SAFETY INFORMATION SPECIFICATION PARTS & CONTROLS General Specification Electrical Specification... Title CONTENTS page 1. SAFETY INFORMATION... 1 2. SPECIFICATION... 2 2-1 General Specification... 2 2-2 Electrical Specification... 5 3. PARTS & CONTROLS... 6 3-1 The Name of Each Parts and Positions...

More information

Variable Regulated DC Power Supplies PAD-LA Series

Variable Regulated DC Power Supplies PAD-LA Series Internet http://www.kikusui.co.jp/ DC Power Supply Variable Regulated DC Power Supplies PAD-LA Series Type III, Type IV, Maximum Output Voltage (16V to 250V) 10 models High Performance and High Reliability

More information

8 or 16 Channel Universal Input Touch Screen Data Logger

8 or 16 Channel Universal Input Touch Screen Data Logger 8 or 16 niversal Input Touch Screen Data Logger OM-DAQXL Stylus (included). OM-DAQXL shown smaller than actual size. 7" Touch Screen TFT Display 8 or 16 Analog Inputs 8 or 16 Virtual (Math) s 8 Digital

More information

LH-50. High-precision measurement using safe LED beam LED TYPE OPTICAL DISPLACEMENT SENSOR. LH01caE0(00/6/28) 01.2.

LH-50. High-precision measurement using safe LED beam LED TYPE OPTICAL DISPLACEMENT SENSOR. LH01caE0(00/6/28) 01.2. LH01caE0(00/6/28) 01.2.14 9:19 PM Page H1 LED TYPE OPTICAL DISPLACEMENT SENSOR High-precision measurement using safe LED beam Conforming to EMC Directive LH01caE0(00/6/28) 01.2.14 9:19 PM Page 1 Minute

More information

BT3563/BT3562/3561. BATTERY HiTESTER

BT3563/BT3562/3561. BATTERY HiTESTER 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BATTERY HiTESTER BT3563/BT3562/3561 Component measuring instruments Simultaneous

More information

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Process Current Output 3B39 FEATURES Interfaces, isolates, & filters a 0 to +10V or -10V to +10V input signal and provides an isolated process current output across loads of 0 to 850Ω.. Intended

More information

ChartView Out-of-the-Box Setup, Acquisition, & Real-Time Display Software

ChartView Out-of-the-Box Setup, Acquisition, & Real-Time Display Software Out-of-the-Box Setup, Acquisition, & Real-Time Display Software ChartView Software Display and record data in minutes, with no programming Display strip charts in real time Make on-screen measurements

More information

DIGITAL MULTIMETERS Programmable Scanner FEATURES INDEX RECORDERS

DIGITAL MULTIMETERS Programmable Scanner FEATURES INDEX RECORDERS Programmable Scanner 426 88 400 mm 5 kg (6-3/4 3-/2 5-3/4" lbs) The is an indispensable tool f the configuration of test and measurement systems that use a wide variety of instrumentation such as DMM s,

More information

Integrating Sound Level Meter. LA-4440 (Class 1) LA-1410 (Class 2) /LA-1440 (Class 2)

Integrating Sound Level Meter. LA-4440 (Class 1) LA-1410 (Class 2) /LA-1440 (Class 2) Integrating Sound Level Meter LA-4440 (Class 1) LA-1410 (Class 2) /LA-1440 (Class 2) Focusing on field measurement with versatile functions, New LA LA-1400 / 4400 series integrating sound level meters

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

Personal Daqs USB Data Acquisition Modules Models /55 & /56

Personal Daqs USB Data Acquisition Modules Models /55 & /56 USB Data Acquisition Modules Models /55 & /56 Features Multi-function data acquisition modules attach to PCs via Universal Serial Bus (USB) Ultra low-power design requires no external power or batteries

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 85 C IP Bearing-Lock High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit protected Reverse polarity protection Optical

More information

3A SERIES MODULAR AC & DC LOADS

3A SERIES MODULAR AC & DC LOADS 3A SERIES MODULAR AC&DC LOADS Key features: Max. Power 300VA per Module Available Voltage Ranges: 60V, 150V and 300 V AC or DC Max. Current Range 20 A AC or DC Choice of Three Modules Up to 4 Load Inputs

More information

Rugged, Professional and Ready for the Field MR MEMORY HiCORDER. Capture high- to low-voltage signals in a single device

Rugged, Professional and Ready for the Field MR MEMORY HiCORDER. Capture high- to low-voltage signals in a single device MEMORY HiCORDER MR8880-20 Recorders Capture high- to low-voltage signals in a single device Rugged, Professional and Ready for the Field CAT III 600 V insulation performance Maximum 600V AC/DC input -

More information

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging ScopeMeter Accessories PC Software Protective Cases SW90W FlukeView ScopeMeter Software for Windows English, French and German language For Fluke 190 & 120 Series ScopeMeter Windows 95/98/Me/NT4.0/2000/XP

More information

1 master and 8 independent stereo subgroup Flexible architecture including a modular control surface, outputs

1 master and 8 independent stereo subgroup Flexible architecture including a modular control surface, outputs Digital Audio Console OXF-R3 High-end digital recording and mix-down console 24 cue/auxiliary send buses, which can be linked for Provides exemplary sound quality and greater functionality stereo than

More information

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03 Overview AG03 is a multi-purpose mixer with USB audio interface, especially optimized for webcasting. Rear Panel Features Input channels: 3 Line Inputs (1 mono, 1 stereo), 1 Mic Inputs with 48V phantom

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

THREE-PHASE POWER QUALITY ANALYZER

THREE-PHASE POWER QUALITY ANALYZER THREE-PHASE POWER QUALITY ANALYZER PowerPad Model 3945-B Display and record waveforms, transients, trend data and events simultaneously! Display real-time color waveforms measurements at a glance Direct

More information

PROGRAMMABLE SCANNER VIEW RECORDERS Programmable Scanner FEATURES

PROGRAMMABLE SCANNER VIEW RECORDERS Programmable Scanner FEATURES Programmable Scanner The is an indispensable tool f the configuration of test and measurement systems that use a wide variety of instrumentation such as DMM s, thermometers, voltage/current source, and

More information

midi LOGGER GL240 Quick Start Guide GL240-UM-850

midi LOGGER GL240 Quick Start Guide GL240-UM-850 midi LOGGER GL240 Quick Start Guide 604249020 GL240-UM-850 Thank you for choose the midi LOGGER GL240. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information