DIGITAL MULTIMETERS Programmable Scanner FEATURES INDEX RECORDERS
|
|
- Chrystal Montgomery
- 5 years ago
- Views:
Transcription
1 Programmable Scanner mm 5 kg (6-3/4 3-/2 5-3/4" lbs) The is an indispensable tool f the configuration of test and measurement systems that use a wide variety of instrumentation such as DMM s, thermometers, voltage/ current source, and other equipment. With its capacity of switches up to 50 input/output channels, plus the large number of functions to suppt their use, it can handle a wide range of applications that require multi-point measurement. What s me, with features like IC memy cards f saving the switching programs, and GP-IB as standard, the handles every scale of automated measurement system, from large to small. FEATURES < Relay card and digital I/O card > Switching f up to 50 channels The has five rear-panel slots f relay card insertion, enabling it to handle swithcing f up to 50 channels (with five cards installed). This makes it ideal f multipoint measurement systems, f everything from semiconduct and electrical/electronic parts testing to temperature distribution measurements. Also, digital I/O card can be inserted into the slots. Relay card (4 types) and digital I/O card The can be fitted with 4 different types of relay card to enable it handle a wide range of applications: generalpurpose multiplexer, thermocouple multiplexer, generalpurpos actuat, and general-purpose matrix. These make it simple to make multi-point measurements of temperature, of electrical quantities such as voltage and resistance. Linearity evaluation of A/D converter and D/A converter is possible using digital I/O cards, which can read/ write digital signals. Meover, by combining these cards you can also use a single like multiple scanner units. Two SCAN modes Either of two SCAN modes can be selected to meet the requirements of your application. CHANNEL mode (CHAN) In CHANNEL mode, the each channels are scanned in succession from the first (starting) to the last (ending) channel. The scan first and last channels can be freely settable. During scanning in CHANNEL mode, each of the scanned switches turns ON one at a time. PROGRAM mode (PRGM) In PROGRAM mode, scanning can be done in whatever sequence the user programs. During scanning in PRO- GRAM mode, and desired number of switches can be turned ON at the same time. Convenient memy functions Internal memy Programs up to 00 steps long, together with control parameters such as scan interval, number of times to repeat 5
2 the scan sequence, and so on can be sted. Since this memy is suppted by battery backup, the memy contents are retained even with power OFF. IC memy card If you use IC memy cards too, you can save the internal memy contents onto the cards up to eight program & parameter sets per card (using a 64K bytes card) and be able to call up different switching patterns quickly whenever you want them. Since these IC memy cards are the same as those used f YOKOGAWA intruments such as the 7560 Series DMM, the 7563 Digital Thermometer, and 765 Programmable DC Source, you can even ste data from other instruments on a single card. FUNCTIONS RELAY CARDS AND I/O CARD (optional) Up to five cards can be installed in the. The user can select any desired mix from among five card types, and can install any card in any slot. < Relay card and digital I/O card circuit diagrams > 7506 General-purpose multiplexer card Programmable Scanner 765 Programmable DC Source 7560 Series Digital Multimeter Thermocouple multiplexer card System-friendly GP-IB (standard) GPIB provides bidirectional communication capabilities f powerful suppt in systems applications. As a listener function, the allows external control of all its functions (except powr ON/OFF), and as a talker function, outputs date and time, switch statuses and program and parameters to the outside. Remote control F remote control, the suppts two signals: a TRIG input (scan advances one to next channel next step on each trigger), and CLOSED output (output as an external relay ON signal). EXTEND The EXTEND function allows you to connect some s together. In this way, you can extend the number of channels up to 00 with two units, 200 with four units, and so on, so that even large-scale systems can be handled using the. Extensive set of user-definable control parameters The provides a full set of parameters that you can set up to control its operation. These include: first channel/last channel, first step/last step, step interval/scan interval, scan count N, and delay. By varying these parameters, you can define a wide range of switching patterns. Numerous convenient functions Auto scan/single scan, skip function, pair function, direct access function, clock function General-purpose actuation card General-purpose matrix card 5
3 75065 Digital I/O card The cycle period with which a series of scanning operations is executed from the start channel through the end channel can be specified in ms, s, min, hour units. The number of repetitions can also be specified from to 99 times. If the number of repetitions is set to 0, scanning repeats until stopped by pressing the STOP key. Pair In CHANNEL mode, this function lets you scan any pair of the same type cards simultaneously. This makes it easy to carry multiple identical tests with high efficiency. CHANNEL SCAN FUNCTION (channel mode: CHAN) In channel mode, the user can specify the scan start cahnnel number and the scan end channel number. When scanning starts, the scan proceeds automatically as the channel number starts, the scan proceeds automatically as the channel number increments. In this mode, only the one switch cresponding to the channel number closes. Skip function If skip is set f a channel, that channel is skipped when the scan is executed. Skip can be specified not only f individual channel numbers, but also f a continuous series of channel numbers from a skip start to a skip end channel number, making it possible to skip an entire group of channels. Step interval The interval between successive channel switching operations is specified by setting the step interval. This can be specified in ms, s, min, hour units. Scan interval/number of repetitions < Scan interval signal > < Software processing > PROGRAMMED SCAN FUNCTION (program mode: PRGM) Program mode lets you define steps from 0 to 99, specifying which relays to open/close f each, after which running the program will execute those steps in sequence. Up to 50 open/close actions can be specified in each step. Meover, since you can specify a scan start step and scan end step, the 00 steps can be divided among multiple programs. To select which to run, the user need only specify the start and end steps. Skip function Skip can be perfmed with step numbers assigned randomly, by specifying skip start and end steps. Step interval The step interval can be used to specify the interval between step switches. 5 < Step interval signal > < Program mode (operating time: ; return time: ) >
4 Scan interval/number of repetitions The cycle period with which a series of scanning operations is executed from the start channel through the end channel can be specified in ms, s, min, hour units. The number of repetitions can also be specified from to 99 times. If the number of repetitions is set to 0, scanning repeats until stopped by pressing the STOP key. Direct access Direct access lets you turn any channel ON OFF directly, independent of the sequence operation. Since this can be achieved from either local remote control, this is very convenient f purposes such as checking system operation. CALENDAR/CLOCK FUNCTION The year, month, day, hour (24-hour clock), and minute can be set and displayed. By setting up a start timer, the user can preset the scan start time. This is very convenient f automated of measurement. CARD MONITOR The card monit provides two functions: the card type function, to display the model name and type ( multiplexer, actuat, matrix digital I/O) of installed cards in each slot: and the card monit function, to display whether the switch of any installed card is ON OFF. These functions let you know the status of any cards easily on the display. Card type function REMOTE CONTROL FUNCTION/EXTEND FUNCTION The following three remote signals can be input and output via the remote control signal connect on the scanner rear. Ext-trigger (input, TTL level) Start signal f control from an external device. Operation starts on falling edge. Closed (output, TTL level) Relay operation end signal. The delay from the time when the relays close until the CLOSED signal in output can be specified in ms s units. Extend start/extend end By specifying one unit as the master and others as slaves, a system can be extended to multiple Programmable Scanners. SPECIFICATIONS GENERAL SPECIFICATIONS Number of Card Slots: 5 Data Memy: Card monit function Type Momy contents Maximum stage capacity Internal Momy Control parameters and scan programs (max. 00 steps) program & parameter set (with battery backup) IC Memy Card Control parameters and scan programs (max. 00 steps) 08k bytes: sets 6K bytes: 2 sets 64K bytes: 8 sets IC MEMORY CARD The channel mode and program mode setup parameters can be saved to an IC memy card and reloaded again whenever needed. GP-IB FUNCTIONS (standard feature) Listener function (receives the following commands from a controller) Commands to perfm any functions that can be executed by panel key operations (except POWER and SRQ keys) Requests f output of panel setup infmation Requests f output of program infmation Requests f output of data read through digital I/O cards Requests f output of devices status. Talker function (ouptuts the following infmation) Panel setupt infmation Program infmation Digital data read from digital I/O cards Divices status Step/Scan Intervals (can be set freely as required): to 9,999 / 20 to 9,999 ms (resolution: ms) to 3,600 s (resolution: s) to,440 min (resolution: min) to 24 hr (resolution: hr) Scan Start Timer: Scan start time can be set in second step, internal clock with calendar function. EXTERNAL TRIGGER Input: TTL level, negative pulse (pulse width; 2 µs min.) CLOSED Output: TTL level, negative pulse (pulse width; approx. 0 µs) CLOSED Output Delay: Settable as required, 0 to 9,999 ms, 0 to 3,600 s. GP-IB Interface: Electrical specifications; Confms to IEEE St d Mechanical specifications; Confms to IEEE St d Function specifications; SHI, AHI, T6, L4, SR, RL, PP0, DC, DT, C0 Operating temperature Range/Humidity Range: 5 to 40 C (4 to 04 F), 20 to 80% (non-condensing) Power Requirements: 90 to 250 V AC continuous (freely settable) Power Consumption: 20 VA max. (with five cards installed) External Dimensions: Approx. 426(W) 88(H) 400(D) mm, (6-3/4 3-/2 5-3/4") Weight: Approx. 5 kg ( lbs)... Mainframe, no relay cards installed 5
5 RELAY CARDS SPECIFICATIONS Contract Ratings Max. Static Isolation Signal Frequency Relay Card Model No. of Lines/CH Voltage between Thermal Switching Path Capacitance Characteristics Crosstalk* 4 Channels between Channels* 3 EMF Time Resistance between * 4 V max. I max. Power* 2 Channels Signal Paths General-purpose multiplexer card Thermocouple multiplexer card* General-purpose actuat card General-purpose matrix card ch 0 ch 0 ch 4 4 ch 3 lines/ch 3 lines/ch 2 lines/ch 3 lines/ch A 00 ma Note: Signal path resistance is guaranteed up to switching operations (at 30 VDC, A, switching time s, resistive load) *Reference junction compensation accuracy: ±0.45 C (at 23 C), ±0.8 F (at 73.4 F) A A 40 W 02 W 40 W 40 W 0 0 Ω 0 9 Ω 0 0 Ω 0 0 Ω 03 µv 03 µv 0 µv 03 µv *2Resistive load *3At 23±5 C (73.4±9 F), 60% R.H. max. *4From top: 00 khz, MHz, 0 MHz (50 Ω termination) 55 pf max. 70 pf max. 25 pf max. 40 pf max. -70 db -50 db -30 db -60 db -40 db -25 db -70 db -50 db -30 db -70 db -50 db -30 db I/O CARD SPECIFICATIONS (75065) Input/Output: 6 bits bidirectional, 8 bits 2 bidirectional Input Signal: 30 V max. H level... V IH 2 V L level... V IL 0.8 V Output Signal: Open collect output H level... V OH 2.4 V (0.2 ma) L level... V OL 0.8 V (50 ma) Timing f Control Signal Output: R/W (H); Signal showing input/output direction of high byte R/W (L); Signal showing input/output direction of low byte R/W (H); H... Input R/W (L); L... Output CONT: Signal showing statuses of Read/Write action READ STANDARD ACCESSORIES No Fuse Name Power Cd Remote connect Plate Bracket Bracket Mounting screws Mounting screws Instruction manual Part No. A2EF A007WD A006WD A009WD A03WD A023WD A003JD B9280KF B9290CW B9290CX Y940LB Y9305LB Q ty Description 2 A, time-lag 00 V system 00 V system (UL standard cd) system (VDE standard cd) system (SAA standard cd) system (BS standard cd) Rack mounting hardware Rack mounting hardware Rack mounting hardware F rack mounting F rack mounting 5 WRITE
6 AVAILABLE MODELS DIMENSIONS Relay Cards Model Suffix Codes 0 Version A... /D Power Cd /F /G /J Digital I/O card Description Mainframe, 90 to 250 V AC, with GP-IB UL standard VDE standard SAA standard BS standard General-purpose multiplexer card Thermocouple multiplexer card General-purpose actuat card General-purpose matrix card 6 bits bidirectional, 8 bits 2 bidirectional Unit: mm (inch) OPTIONAL ACCESSORIES < Rack mounting kit > Code Name Description Order Q ty IC memy card 8K bytes pc IC memy card 6K bytes pc IC memy card 64K bytes pc. B9586NG Dummy card Dust cover f IC memy card slot 2 pcs. 5 ORDERING INFORMATION When dering, specify:. Instrument name, model and codes. 2. Name and code of optional accessy, if required.
PROGRAMMABLE SCANNER VIEW RECORDERS Programmable Scanner FEATURES
Programmable Scanner The is an indispensable tool f the configuration of test and measurement systems that use a wide variety of instrumentation such as DMM s, thermometers, voltage/current source, and
More informationHigh Density Switch Mainframe and Cards
Cost-effective, high density switch mainframe and cards High density, half-rack switching mainframe, just 2U (3.5 in) high Differential 6 32 matrix card Differential quad 1 40 multiplexer card Analog backplane
More informationKeysight U2751A USB Modular Switch Matrix
Keysight U2751A USB Modular Switch Matrix The Keysight Technologies, Inc. U2751A USB modular switch matrix offers a high quality, low-cost switching solution for automated testing. It has 32 two-wire cross
More informationAgilent U2751A USB Modular Switch Matrix. Data Sheet
Agilent U2751A USB Modular Switch Matrix Data Sheet Features and capabilities 32 two-wire crosspoints in 4x8 configuration Minimal crosstalk at up to 45 MHz Bandwidth of 45 MHz without the terminal block
More informationModel 3724 Dual 1x30 FET Multiplexer Card
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Model 3724 Dual 1x30 FET Multiplexer Card Connection Instructions Introduction This instruction sheet
More informationIEEE 488/GPIB BUS INTERFACE GPIB TO RELAY INTERFACE DESCRIPTION. GPIB Controlled relays and isolated digital inputs
DESCRIPTION The Model 4864 is an IEEE 488.2/GPIB/ HP-IB to Relay Interface that provides 6 fm A contacts 6 relay drivers f switching signals f driving external relays. The 4864 s versatile commands let
More informationCPU Units with 20 I/O points
CPM2A General s CPU Units with 20 I/O points CPU Units with 30 I/O points CPU Units with 40 I/O points Supply voltage AC power 100 to 240 VAC, 50/60 Hz DC power 24 VDC Operating voltage AC power 85 to
More informationEDX-10 Series. Compact Recording System
3-49 EDX-10 Series Compact Recording System Compact, lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls
More informationEDX-10 Series. Compact Recording System
3-51 EDX-10 Series Compact Recording System Compact & lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls
More informationCPM1A MICRO PROGRAMMABLE CONTROLLERS
CPM1A MICRO PROGRAMMABLE CONTROLLERS Complete Small Scale Control The popular CPM1A family of micro PLCs now includes models with AC inputs. In one product family, you get cost- and space-efficient controllers
More informationS-2900A. Rev.1.1. CMOS 512-bit SERIAL E 2 PROM
Rev.1.1 CMOS 512-bit SERIAL E 2 PROM S-29A The S-29A is a wide operating voltage range, low power consumption 512-bit E 2 PROM. The organization is 64-word 8-bit, and can be read or written serially. It
More informationIEEE 488/USB BUS INTERFACES
IEEE 488/USB BUS INTERFACES USBParallel Digital Interface Provides 40 user configured digital I/O lines. Inputs TTL/CMOS and contact closures. Drives 48 ma. Automatic event and status change detection.
More informationLGR-5325 Specifications
s Revision 1.0, April, 2010 Copyright 2010, Measurement Computing Corporation s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in italic text are
More informationA variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation
ECONseries BUS: USB Type: Economy, Mini-Instruments ECONseries Economy USB Mini-Instruments Flexible Yet Economical A variety of low-cost ECONseries modules are available to provide flexible yet economical
More informationREGULATED DC POWER SUPPLIES
Regulated DC Power Supplies Meter display 18V/10A PD18-10A 18V/20A PD18-20A 18V/30A PD18-30A 36V/10A PD36-10A 36V/20A PD36-20A 56V/6A PD56-6A 56V/10A PD56-10A 110V/3A PD110-3A 110V/5A PD110-5A Digital
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More information3156 LEAK CURRENT HiTESTER
2003 3156 LEAK CURRENT HiTESTER Safety Standards Measuring Instruments The Long-Awaited Bench-type Model Is Here! Leakage Current Measurement Essential for Electrical Safety Because of the risks it poses,
More informationContinuous Measurement up to 43 MS/s
Continuous Measurement up to 43 MS/s Time Interval Analyzer Maximum continuous sampling rate 43 Ms/s Maximum sampling size 0 9 data samples 25 ps measurement resolution 00 ps internal jitter Built-in printer
More informationModular Power System 1200 W per mainframe GPIB
View at www.testequipmentdepot.com High Performance DC Power Supplies 1200 W per mainframe GPIB Modular system permits up to 8 outputs of 150 W per output in 4 U of rack space Reconfigure fast with easily
More informationUSB 1608G Series USB Multifunction Devices
USB Multifunction Devices Features 16-bit high-speed USB devices Acquisition rates ranging from 250 ks/s to 500 ks/s differential (DIFF) or 16 singleended (SE) analog inputs (softwareselectable) Up to
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationDespite its ultra-slim design, a CPM2C system can provide up to 192 I/O points!
Despite its ultra-slim design, a CPM2C system can provide up to 192 I/O! Model Numbers Expansion I/O Units Name CPM1A-8ET 8 input Transistor outputs (sinking) CPM1A-8ED 8 DC inputs CPM1A-8ER 8 relay outputs
More information360W and 720W Programmable DC Power Supplies
3-Year Warranty Series 2260B 360W and 720W versions with voltage up to 80V and current up to 72A Combine power supplies in serial and parallel combinations to expand voltage and current outputs up to 160V
More informationWARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.
55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger
More informationproduct HP 3499A/B Switch/Control Mainframe Test at the speed of the Revolution
product HP 3499A/B Switch/Control Mainframe Test at the speed of the Revolution CONFIDENCE It s what switching means to your test system HP 3499A/B Switch/Control Mainframe HP 3499 family is a high speed,
More informationSpecifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T
3-57 Universal Recorder -2H Improved real-time processing function with high-speed DSP Incorporated real-time digital filter 8th digital filter enables to acquire clear waveform. High-speed/low-speed dual
More information6146/6156 DC Voltage/Current Source Standard power source best used as calibrator and secondary battery simulator
6146/6156 DC Voltage/Current Source Standard power source best used as calibrator and secondary battery simulator l Wide dynamic range of sourcing 6146 Voltage: 0 to ±32.000V Current: 0 to ±220.00mA 6156
More informationModel 3750 Multifunction I/O Card
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Model 3750 Multifunction I/O Card Connection Instructions and Specifications Introduction This instruction
More informationCheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:
CheckSum FUNC-2B Functional Test Module FUNC-2B Functional Test Module Made in U.S.A. The CheckSum Model FUNC-2B Functional Test System is designed to be used as an extension to a CheckSum ICT System.
More informationLGR-5327 Specifications
s Revision 1.0, April, 2010 Copyright 2010, Measurement Computing Corporation All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in italic text are
More informationUSB-1602HS-2AO Specifications
s Revision 1.0, March, 2009 Copyright 2009, Measurement Computing Corporation s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. All signal names refer
More informationAgilent 66000A 1200 W DC Modular Power System, GPIB
Agilent 66000A 1200 W DC Modular Power System, GPIB Data Sheet Speed and accuracy for test optimization 8-slot mainframe accepts up to 8 DC power modules 1200 W total DC power output, up to 150 W per module
More informationCQM1 THE FLEXIBLE, HIGH SPEED CONTROL SOLUTION
CQM1 THE FLEXIBLE, HIGH SPEED CONTROL SOLUTION CQM1 Controlling Quality with this Exceptional Machine Take control of your small machine applications with Omron s CQM1 PLC. It offers many hardware options,
More informationS-2900A. Rev CMOS 512-bit SERIAL E 2 PROM
Rev.1.11 CMOS 512-bit SERIAL E 2 PROM S-29A The S-29A is a wide operating voltage range, low power consumption 512-bit E 2 PROM. The organization is 64-word 8-bit, and can be read or written serially.
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationProgrammable Power Supplies 188 W 384 W HMP Series
Programmable Power Supplies 188 W 384 W The 2, 3 or 4 Channels Key facts The four power supply units,, HMP4030 and HMP4040 from HAMEG Instruments offer you the choice between 2, 3 and 4 channels with a
More informationAgilent L4421A 40-Channel Armature Multiplexer
Agilent L4421A 40-Channel Armature Multiplexer Data Sheet LXI compliance includes built-in Ethernet connectivity Fully-featured graphical Web interface 40 2-wire latching armature relays Thermocouple reference
More information12-Channel Thermocouple Datalogger
User Manual 12-Channel Thermocouple Datalogger Model TM500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech TM500 Thermometer,
More information6220 Ethernet-Based Voltage Measurement Module
Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100 khz per channel sample rate ±10 V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger modes
More informationIEEE 488/GPIB BUS INTERFACES
DESCRIPTION The Model 4813 GPIB Digital Interface Board is an IEEE-488.2/GPIB to digital interface with 128 I/O lines that can be used to easily adapt devices with a large number of digital signals
More informationUSB-2527 Specifications
Specifications Document Revision 1.4, February, 2010 Copyright 2010, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design.
More informationUSB-1616FS. Analog Input and Digital I/O. Specifications
Analog Input and Digital I/O Specifications Document Revision 1.6 May 2012 Copyright 2012 Specifications All specifications are subject to change without notice. Typical for 25 C unless otherwise specified.
More informationVariable Regulated DC Power Supplies PAD-LA Series
Internet http://www.kikusui.co.jp/ DC Power Supply Variable Regulated DC Power Supplies PAD-LA Series Type III, Type IV, Maximum Output Voltage (16V to 250V) 10 models High Performance and High Reliability
More informationController module. Brief description. Features. Block structure. Data Sheet Page 1/7
M. K. Juchheim GmbH & Co UK USA Jumo Instrument Co. Ltd. Jumo Process Control Inc. 36035 Fulda, Germany Temple Bank, Riverway 735 Fox Chase Phone (0661) 6003-0 Harlow, Essex CM20 2TT Coatesville, PA 19320
More informationUSB 1608G Series USB Multifunction Devices
USB Multifunction Devices Features 16-bit high-speed USB devices Acquisition rates ranging from 250 ks/s to 500 ks/s differential (DIFF) or 16 singleended (SE) analog inputs (softwareselectable) Up to
More informationController module. Brief description. Features. Block structure. Page 1/7. Data Sheet
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More information964i High Voltage Switching System
964i High Voltage Switching System The Perfect Solution for Automated Multi-Conductor, Multi-Point Hipot Testing You have a job to do you have to hipot test a 16 conductor medical cable at 8500V to ensure
More informationTechnical Specifications May 2003
Agilent 8163B Lightwave Multimeter Agilent 8164B Lightwave Measurement System Agilent 8166B Lightwave Multichannel System Technical Specifications May 2003 Agilent 8163B Mainframe The Agilent lightwave
More informationProgrammable DC power supplies
3-Year Warranty Series 2260B 360W, 720W, and 1080W versions with voltages up to 800V and currents up to 108A Programmable voltage or current rise and fall times prevents damage to low impedance loads from
More informationFeatures. Description. Applications
Description Features The electronic loads of the ZSAC series are optimized for the practical use in laboratories, manufacturing and quality control. Power: Voltage: Current: 400W... 12600W 260V... 440V
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com GW Instek PSU-series power supply with 1U height is highly praised by various markets
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationTime Inter val Analyzer
Time Inter val Analyzer 2nd Edition Foreword Thank you for purchasing the YOKOGAWA TA520 Time Interval Analyzer. This User s Manual contains useful information about the precautions, functions, and operating
More informationPRODUCT OVERVIEW CPM2A
PRODUCT OVERVIEW CPM2A Micro Controller CPU and Expansion Modules The CPM2A series micro controllers are among some of the most powerful small-scale control solutions in the micro PLC industry today. With
More informationProgrammable DC Power Supplies XLN Series
Data Sheet New Family of High Density System Power Supplies The B&K Precision XLN series are programmable, single-output DC power supplies, that provide clean power up to 1560 watts in a compact 1U rackmountable
More informationInform IT Single Pen Circular Chart Recorder
Data Sheet SS/_ Inform IT Single Pen Circular Chart Recorder Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers included as standard -digit indicator
More informationAMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES
Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable
More informationUSER MANUAL. SATEL i-link. I/O-converter. Version 1.4
USER MANUAL SATEL i-link I/O-converter Version 1.4 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTICE... 3 PRODUCT CONFORMITY... 4 WARRANTY AND SAFETY INSTRUCTIONS... 5 1 GENERAL... 6 1.1 SATEL
More informationMOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)
MOS FET Relay G3VM- XN(F)/4N(F) SSR for Switching Analog Signals, with an I/O Dielectric Strength of 2.5 kvac Using Optical Isolation Switches minute analog signals. Linear voltage and current characteristics.
More informationSpecifications USB-1616HS
Document Revision 1.0, August, 2007 Copyright 2007, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input A/D
More informationDS1302. Trickle Charge Timekeeping Chip FEATURES PIN ASSIGNMENT PIN DESCRIPTION
DS132 Trickle Charge Timekeeping Chip FEATURES Real time clock counts seconds, minutes, hours, date of the month, month, day of the week, and year with leap year compensation valid up to 21 31 x 8 RAM
More informationVersatile, Automatic RCL Meters
Versatile, Automatic RCL Meters Technical Specifications PM 6306 / PM 6304 / PM 6303A PM 6306 and PM 6304 Versatile component measurement and testing Easy to use, at-a-glance display Test frequencies,
More informationSolid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)
Solid-state Timer Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple
More informationExpanding the Basic GL7000 Configuration
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Expanding the Basic GL7000 Configuration The GL7000 is a modular system that allows you to add analog
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationMicroBench MB-500A. Live Logic Logic source pattern generator Logic analyzer Arbitrary waveform generator Protocol interactive test
Providing tools for Embedded Engineers Digital Designers MicroBench MB-500A a complete digital tool set Technical Data Five test tools in one compact, affordable instrument: Live Logic Logic source pattern
More informationPaperless Recorder VGR-B100. Series
Paperless Recorder VGR-B100 Series CE marking RoHS compliant Easy-to-Use! Paperless Recorder with Touch Screen VGR-B100 Easy Operation! Touch Screen Operation User friendly interface through a 5.7 inch
More informationSpecifications USB-1616FS
Document Revision 1.5, July, 2006 Copyright 2006, Measurement Computing Corporation Typical for 25 C unless otherwise specified. in italic text are guaranteed by design. Analog input A/D converters Number
More informationUserss Manual. GP-IB Adapter
Userss Manual GP-IB Adapter ZS-6120C Series ZS-6120CP ZS-6120CH Zenisu Keisoku,Inc. ZIP code: 183-0027 2-13-37, Honmachi, Fuchu, Tokyo, Japan TEL: +81-(0)42-368-2126 FAX: +81-(0)42-364-0067 Introduction
More information4164 Switch Matrix System Description
On the New Frontiers of Precision A Quantum Switch for the Better Precision 4164 Switch Matrix High Density Programmable 64x64 Switch Matrix System The Precision 4164 Switch Matrix System is a reliable
More informationAvailable for low voltage and high current High slew rate with 100A/μs
Low voltage input and high slew rate electronic load Available for low voltage and high current High slew rate with 100A/μs Low voltage input and high slew rate electronic load Kenwood TMI Corporation
More informationModel 707B / 708B Switching Matrix Mainframe Specifications Model 707B Six Slots with Fixed Rack Model 708B Single Slot with Fixed Rack
Overview: Capacity: Model 707B / 708B Model 707B 708B Description Six plug-in cards per mainframe Single plug-in card per mainframe Supported Cards Model Description 7072 8x12 Semiconductor Matrix 200V,
More informationCJ1W-PTS/PDC/PH41U/AD04U
CJ-series Process Analog I/O Unit A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 ma or 1 to 5 V) A Unit supports four input channels,
More informationA S C O R I N C O R P O R A T E D VXI MODULES
A S C O R I N C O R P O R A T E D VXI MODULES General Purpose Switch Modules Most VXI test environments require general purpose switching capabilities to enable and disable particular I/O circuits, especially
More informationKeysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies
Keysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies Speed and accuracy for test optimization Data Sheet Introduction This reliable series of 500 W DC power supplies can be controlled
More informationPower Supply Controller Power Supply Controller PIA4800 Series
Power Supply Controller Power Supply Controller PIA4800 Series Capable of controlling various power supplies and electronic loads. Suppts multiple channels via a highly extensible slot-in system. Equipped
More informationFEATURES DESCRIPTION SPECIFICATIONS
KNC-PLC-KS105 - Series FEATURES Four High-Speed Counters, Max 200 khz Four High-Speed Outputs, Max 200 khz 24VDC Power Required 8 Digital Inputs, 8 Digital Outputs 3 Year Lithium Battery for Data Retention
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Handy Calibrators
99 Washington Street Melrose, MA 02176 Fax 7816650780 TestEquipmentDepot.com Handy Calibrators / Voltage/Current Calibrator Temperature Calibrator Both signal source and measurement functions Simple operation,
More informationSD Series. modular stepping drives. Rack mounting stepper drives with AC or DC power input. Automation. SD series features
SD modular stepping drives Rack mounting stepper drives with AC or DC power input SD drives are full/half and ministepping modules that offer high standards of performance for low to medium power applications.
More informationDS2223/DS2224. EconoRAM FEATURES PACKAGE OUTLINE. PIN CONNECTIONS Pin 1 GND Ground Pin 2 DQ Data In/Out Pin 3 V CC Supply Pin 4 GND Ground
DS2223/DS2224 EconoRAM FEATURES Low cost, general purpose, 256 bit memory DS2223 has 256 bit SRAM DS2224 has 32 bit ROM, 224 bit SRAM Reduces control, address and data interface to a single pin PACKAGE
More informationAgilent U2751A USB Modular Switch Matrix. Data Sheet
Agilent U2751A USB Modular Switch Matrix Data Sheet Features and capabilities 32 two-wire crosspoints in 4x8 configuration Minimal crosstalk at up to 45 MHz Bandwidth of 45 MHz without the terminal block
More informationVariable Regulated DC Power Supplies PAD-LA Series
Internet http://www.kikusui.co.jp/ DC Power Supply Variable Regulated DC Power Supplies PAD-LA Series Type III, Type IV, Maximum Output Voltage (16V to 250V) 10 models High Performance and High Reliability
More informationKTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters
Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,
More informationDM-OLED X 64 BLUE GRAPHIC OLED DISPLAY MODULE WITH SPI, I2C INTERFACE
1.3 128 X 64 BLUE GRAPHIC OLED DISPLAY MODULE WITH SPI, I2C INTERFACE Contents Revision History Main Features Pin Description Panel Pin Description Module Pin Description Mechanical Drawing Panel Mechanical
More informationDS28CM00. I²C/SMBus Silicon Serial Number
DS28CM00 I²C/SMBus Silicon Serial Number www.maxim-ic.com GENERAL DESCRIPTION The DS28CM00 is a low-cost, electronic registration number to provide an absolutely unique identity that can be determined
More informationAndover ContinuumTM. b3850 Series Terminal Controllers
TM b3850 Series Terminal Controllers The TM b3850 series controllers are native BACnet controllers that communicate on an RS-485 field bus as Master devices using the MS/TP BACnet protocol. 02 Features
More informationGL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.
GL820 midi Logger Built-in 5.7" TFT LCD Color Display Stand-alone or PCconnected operation 20 Analog Channels Standard, Expandable to 200 Input-to-output and channel-to-channel Isolation USB and Ethernet
More informationOverview: Functional Description:
CPCI-ADADIO 12-Channel 16-Bit Analog I/O CPCI Card With 8 Simultaneous Input Channels at 200K Samples per Second per Channel, 4 Output Channels, and Byte-Wide Digital I/O Port Features Include: 8 Analog
More informationADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13
ADAM-6200 Series Feature DI/O LED Indication Flexible user-defined Modbus address 19 20 21 DAQ Boards Signal Conditioning Industrial USB I/O Modules22 Transition and Vision on Remote DAQ Device In 2002,
More information(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)
Solid-state Relay Compact SSRs Ideal for Built-in Applications Vertical, compact SSRs with an operation indicator offered in versatile variations. Can be mounted side by side with an electromagnetic relay
More informationD7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES
11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet
More informationSourceMeter Airbag Test System
2790 Single-instrument solution for continuity and hi-pot type leakage resistance measurements Programmable constant V source (50 500V) supports high speed, high resistance measurements Programmable constant
More informationORDERING INFORMATION. OPERATION Measuring Temperature A block diagram of the DS1621 is shown in Figure 1. DESCRIPTION ORDERING PACKAGE
AVAILABLE Digital Thermometer and Thermostat FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67
More informationmxcontrol Multifunction Controller
mxcontrol Multifunction Controller Data and event logging One controller hardware with dozens of configuration possibilities quickly downloaded via SD card (supplied) or via USB interface Type 8620 can
More informationProgrammable D.C. Electronic Load
Programmable D.C. Electronic Load D35 PEL-2004 PEL-2002 FEATURES NEW NEW * Sequence Function to do High Speed Load Simulations * Flexible Configuration with Mainframes and Plug-in Modules * Multiple Independent
More informationPreliminary Data MOS IC. Type Ordering Code Package SDA Q67100-H5092 P-DIP-8-1
Nonvolatile Memory 1-Kbit E 2 PROM SDA 2516-5 Preliminary Data MOS IC Features Word-organized reprogrammable nonvolatile memory in n-channel floating-gate technology (E 2 PROM) 128 8-bit organization Supply
More information2790 SourceMeter Airbag Test System
2790 Meter Airbag Test System Single-instrument solution for continuity and hi-pot type leakage resistance measurements Programmable constant V source (50 500V) supports high speed, high resistance measurements
More informationSwift Responses with Accurate Measurement
Swift Responses with Accurate Measurement The /1503D are equipped with the excellent transient recovery time, which can, in less than 40us, recover the output voltage to within 100mV of the previous voltage
More informationData sheet CPU 115 (115-6BL02)
Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,
More informationElectronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition
Electronic Multi-channel Load PMLA 150 W / 600 W 40 V up to 240 V 1 A up to 120 A Preliminary Edition Functionality Interface Overview Master RS-232 X CAN O USB X Analog O LAN X Analog isoliert / GPIB
More information