1 Protection systems 1st Edition

2 9 / 0 5 x x x x x x Protection Systeme w w w. a d c k r o n e. c o m ( 0 )

3 Table of Contents 02 / BE P ro t e c t i o n S y s t e m s Technical Reference Overview Protection systems in the communications network Applications of overvoltage protection Different forms of overvoltage Recommendations for the application of protection measures Costs and benefits for the user Operating conditions Selection Operating voltage/technical data Fail-safe Choosing protection components System Overview ComProtect protection plugs for LSA-PLUS and LSA PROFIL 1-, 8- and 10-pair solutions Magazines for LSA-PLUS, LSA PROFIL and Main Distribution Frames (MDF Technical specifications ComProtect Overvoltage Protection LSA-PLUS and LSA PROFIL Modules Basic Protection Magazine for LSA-PLUS Series 2 Blocks Pole Overvoltage Arrestors Fail-Safe Contact Magazine Cover Basic Protection Magazine for LSA-PLUS Series 8 Blocks Basic Protection Plugs for LSA-PLUS Series 2 Blocks Intermediate Protection Plugs for LSA-PLUS Series 2 Blocks Data Protection Plug for LSA-PLUS Series 2 Blocks Current Protection Plug for LSA-PLUS Series 2 Blocks Accessories for Intermediate Protection Plugs Advanced Protection Plugs for LSA-PLUS Series 2 Blocks Maintenance-Free Protection Plug for LSA-PLUS Series 2 Blocks Earth Plug for LSA-PLUS Series 2 Blocks Earth Bars for LSA-PLUS Modules LSA-PLUS and LSA PROFIL NT Modules Basic Protection Magazine for LSA-PLUS NT Modules Basic Protection Plug for LSA-PLUS NT Modules Intermediate Protection Plugs for LSA-PLUS NT Modules Advanced Protection Plug for LSA-PLUS NT Modules High-Speed Data Protection Plug for LSA-PLUS NT Modules Maintenance-Free Protection Plug for LSA-PLUS NT Modules Accessories for LSA-PLUS and LSA PROFIL NT Module Overvoltage Protection LSA-PLUS DIRECT Module Integrated Maintenance-Free Protection LSA-PLUS DIRECT Module HighBand 10 Modules ADSL Protection for HighBand 10 Modules Main Distribution Frame 71 Basic 5-Pair Protection Magazine for the MDF Basic 4-Pair Protection Magazine for the MDF Pole Overvoltage Arrestors Pole Overvoltage Arrestors Overcurrent Protection Plugs Maintenance-Free ADSL Protection Plugs for the MDF Maintenance-free ADSL Protection Plug for MDF Flex MDF-Block Next Generation MDF Block with Maintenance-Free Overvoltage Protection Mini-distributor ComGuard Maintenance-Free Overvoltage Protection System for Demarcation Points ComGuard Mini-distributor for ComProtect Protection Plugs Test Device and Protection Components Number Index Alphabetical Index Technical Reference Table of Contents w w w w. a. da dc ck kr ro on n e.. c o m (( 0 ))

4 Technical Reference 02 / Protection Systems w w w. a d c k r o n e. c o m ( 0 )

5 Technical Reference Overview Technical Reference 02 / BE P ro t e c t i o n S y s t e m s Technical Reference w w w. a d c k r o n e. c o m ( 0 )

6 Technical Reference Overview Protection systems in the communications network The importance of overvoltage protection has increased considerably over the past years. On one hand, this is due to growing demands placed on advanced communications systems that increasingly support voice, video and data transmissions. On the other, the deployment of electronics further into the network has resulted in miniaturisation with an increased integration density and hence reduced electrical strength. Connection and distribution technologies from ADC KRONE set a global standard and are supplemented by a powerful and flexible portfolio of protection solutions. Individual protection possibilities enable an optimum cost-to-benefit ratio and ensure maximum economic efficiency for the user. Technical Reference Applications of overvoltage protection Protection systems are used wherever communication lines are distributed and connected. Overvoltage protection fulfils various requirements, depending on the type of installation to be protected. In conventional switching equipment, overvoltage protection is used primarily to protect people. In highly sensitive electronic switching equipment installations, however, comprehensive protection measures are necessary in order to protect not just people, but also the valuable installation itself. Overvoltage is undoubtedly the primary cause of faults, i.e. interference caused by electrical energy disturbances in communication lines. The term overvoltage often calls to mind thunderstorms releasing vast amounts of energy. However, even static discharges, which may appear to be harmless, can seriously affect signal transmission or even paralyse entire networks. Overvoltage in supply lines for centrally controlled process management and control systems can sometimes lead to immense damage and costs into the millions, or even to irrecoverable losses. Different forms of overvoltage Although the different forms of overvoltage have basically remained unchanged for many years, their causes and effects are subject to change. Overvoltage can be caused not only by reproducible interferences, but also by impulses that occur randomly. Reproducible excess voltages caused, for example, by capacitive or inductive switching, are often easy to localise and suppress. In order to achieve efficient protection against excess voltages caused by non-reproducible interferences, a range of standards and recommendations can be adopted with a view to causes, duration and injection of such interferences into the system. Overvoltage in communication networks is usually the result of electromagnetic interference, equalising currents between different earth potentials or network short circuits. This is caused by switching operations on neighbouring lines, the indirect effect of lightning or natural forces, or by human error. The direct effect of lightning on distribution equipment is an exception, because this type of equipment is usually installed indoors or in enclosures. The massive amount of energy involved in direct lightning strikes requires separate protection concepts and structural measures. Apart from direct lightning strikes, however, interference by one of the following phenomena is more often than not the cause of damage to or destruction of communication systems: Indirect lightning impact Electromagnetic interference Inductive or capacitive effects Electrostatic discharge Contact with live power lines These conditions often represent a high degree of danger to human life. w w w. a d c k r o n e. c o m ( 0 )

7 Technical Reference Overview Recommendations for the application of protection measures Overvoltage protection devices consist of components or protective circuits that limit interference to permissible values. Overvoltage protection devices must adapt to regional and local requirements. These requirements include operating conditions on the line and the protection requirements that result from the specific application area. Graded protective circuits with secondary protection elements should be used for incoming circuits on the exchange side and for terminal equipment (telephone, fax, modem), because in addition to personnel safety, sensitive electronic systems must also be protected. High voltage protection is usually sufficient for the line. In the event that active components are installed in a cross-connection cabinet, graded protective circuits are also recommended. Costs and benefits for the user When selecting suitable overvoltage protection modules, the cost-to-benefit ratio is of interest. The cost of installing protection modules contrasts favourably to the increased availability of the communication network and lower repair costs. An optimum selection on the part of the network operator results in minimum costs with maximum economic efficiency of the equipment. The extent of protection measures is based on the requirements and specifications from the network operator or the equipment manufacturer. In the idealised diagram shown here, the cost minimum is the point where the two curves meet. In order to protect personnel, applicable standards and regulations for setting up and operating telecommunications networks must also be observed. Technical Reference The applicable standardsand/or regulations for setting up and operating telecommunication networks must also be observed to protect personnel w w w. a d c k r o n e. c o m ( 0 )

8 Technical Reference Overview Technical Reference 02 / BE P ro t e c t i o n S y s t e m s Operating conditions ADC KRONE s range of protection system products is designed to meet the needs of our copperbased connection and distribution systems. In most applications, the protection modules are electrically equivalent; however, they are not necessarily compatible in their contact and protection behaviour. Basic differentiators include: Operating behaviour of the system to be protected Overvoltage protection requirements (electrical and mechanical) e.g., requirements facing the permissible impulse current or the permissible AC discharge current. The network operator s specifications must be observed when designing the protection modules. The LSA-PLUS, LSA PROFIL or MDF 71 connection system used Requirements for protection for a single pair, or an entire module Furthermore, protection equipment and systems must be designed to meet the needs of the following network conditions. Before the planning phase begins, the requirements for the protection system must be examined together with the operating conditions. An over-designed protection system rarely leads to damage. However, it does impact the economic efficiency of the equipment. Over-designed protection also means an increase in repair costs and poses a personnel risk. Installation takes place after the distribution equipment has been set up. Retrofitting existing equipment is, in most cases, not a problem if LSA-PLUS and LSA PROFIL systems are installed. Network condition Selection condition Protection module Operating voltage < Response voltage Voltage resistance of the equipment to be protected > Impulse response voltage Nominal current < Nominal current Cut-off frequency (transmission rates) < Cut-off frequency Aside from the electrical characteristics, the conditions of the interface with the distributor system and, if necessary, the housing dimensions must be taken into consideration at the earliest possible stage. The following protection modules are available for the LSA-PLUS Series 2 blocks and for LSA-PLUS NT Protection Modules LSA-PLUS Distribution Blocks Jumpering with protection element in place Magazines Connection or disconnection no 1-pair ComProtect A series Connection or disconnection yes 1-pair ComProtect B series Disconnection or switching yes 1-pair ComProtect H series Disconnection or switching yes 1-pair ComProtect NTP series Disconnection or switching no w w w. a d c k r o n e. c o m ( 0 )

9 Technical Reference Overview Operating conditions Distribution modules with disconnection, switching and connection contacts can be used with ADC KRONE protection components. Disconnection and switching modules permit the insertion of serial protection components into circuits; connection modules only permit parallel contact access. 02 / BE P ro t e c t i o n S y s t e m s Selection Regardless of the series and circuit used, overvoltage protection components are all based on the same working principle: any excessive voltages are discharged to earth. Depending on the component, the energy consumption in the protection device is relatively small. One precondition for this is the protection component s low-resistance earthing. In line with signal potentials, a distinction is made between three-point and five-point protection. For connection modules, only threepoint protection is possible. Five-point protection (components in the signal path) is recommended for use with switching modules. Once the protective plug is removed, the contact in the module is open and possible faults cannot make their way to the downstream network. Fivepoint protection can also be implemented using disconnection modules. ADC KRONE supplies various protective circuits: Three-point protection: pure overvoltage protection (high-voltage or secondary protection) Five-point protection: overvoltage protection combined with current protection Five-point protection: graded protection (high-voltage and secondary protection with current protection) Components designed for single-pair protection provide a safe and reliable solution in LSA-PLUS and LSA PROFIL distribution systems and have advantages over multiple-pair protection magazines for eight- and/or ten-pair modules. When a single-pair protection plug has to be removed, this does not mean that the entire module (all eight or ten pairs) is then left unprotected. Partial or combined equipping of the modules is also possible. Because of their small dimensions, the most convenient protection plugs (ComProtect A, B and H series) also offer the option of switching and jumpering with protection components in place. All protection functions thus remain guaranteed at all times for both the communication equipment and maintenance personnel. Technical Reference The advantages of protection magazines for eight and ten pairs are mainly based on the fast set up and lower installation costs of a protection panel. When necessary, protection magazines for LSA-PLUS and LSA PROFIL can be installed in the distributor in combination with ComProtect components w w w. a d c k r o n e. c o m ( 0 )

10 Technical Reference Overview Technical Reference 02 / BE P ro t e c t i o n S y s t e m s Operating voltage/technical data The operating voltage of the system to be protected determines the protection plug s voltage class. The protection device must not be triggered during normal operation. This would not only destroy the protective circuit, it would also lead to interruption in signal transmission. The highest possible voltage class should be selected for the protection plug at least above the maximum voltage possible during operation (maximum operating voltage, including tolerance). The upper limit for selecting the protection plug s voltage class is determined by the maximum protection level permitted, i.e., the maximum input voltage that would not damage the downstream system components should overvoltage occur. The selection of components and switching configurations determines other electrical parameters for protective circuits. Properly designed and specified overvoltage protection components have a serviceable life of several decades and require no additional maintenance. ADC KRONE recommends that the nominal DC spark-over voltage of installed protection components be tested regularly. For safety reasons, the arrestors should be replaced if the protective circuit has been subjected to impulse current. Fail-safe Protective circuits with an integrated fail-safe feature are highly recommended. Components for overvoltage protection are usually designed only for pulse-shaped loads. Therefore, if permanent overloads are possible (e.g., mains contact), a safe short-circuit to earth must be ensured. Overloaded or overheated protection components would not only lose their protection function, they could cause fire or an explosion, leading to considerable damage and expense. w w w. a d c k r o n e. c o m ( 0 )

11 Technical Reference Overview Choosing protection components The mechanical interface where the protection components is going to be installed has to be taken into account. ADC KRONE offers a large number of complete magazine solutions and flexible single-pair protection plugs. Our product portfolio offers various levels of protection with extended features that have a direct influence on the severity of the network downtime and the associated commercial loss. 02 / BE P ro t e c t i o n S y s t e m s The ADC KRONE portfolio includes a broad range of performance classes: Basic protection plugs Intermediate protection plugs Advanced protection plugs Maintenance-free advanced protection plugs Given the number and variety of applications and new transmission modes employed in communications networks, please refer to the tables on pages 8 and 9 for a detailed overview of the available protection components in association with transmission rates and other network features as a basis for choosing the protection type best suited to your application. Technical Reference w w w. a d c k r o n e. c o m ( 0 )

12 Technical Reference System Overview Telecommunication Data MCRS Technical Reference 02 / BE P ro t e c t i o n S y s t e m s Recommended applications Operating voltage Operating current Transmission rate Analoge Lines ISDN S 0 -interface ISDN S2M-interface PMXA primary multiplexer connection PCM (without remote power feeding) PCM (with remote power feeding) PCM11 (with sym. remote power feeding) Modem for telephone line Modem for Datex P ADSL transmission RS 232 RS 485 Ethernet (CAT5) Token ring TTL-Level TTY-Level Status display 160 V 42 V 100 V 60 V 5 V 100 V 320 V 60 V 12 V 160 V 12 V 12 V 5 V 5 V 5 V 24 V 24 V < 100mA < 60 ma < 120 ma < 60 ma < 60 ma < 60 ma < 60 ma < 60 ma < 60 ma < 120 ma < 20 ma < 20 ma < 20 ma < 20 ma < 20 ma < 20 ma < 20 ma 4 khz 192 kbit/s 2 Mbit/s 2 Mbit/s 2 Mbit/s 2 Mbit/s 2 Mbit/s 64 kbit/s 48 kbit/s 8 Mbit/s 20 kbit/s 2 Mbit/s 100 Mbit/s 16 Mbit/s 64 kbit/s 64 kbit/s 64 kbit/s ComProtect Cat. number For LSA-PLUS and LSA PROFIL modules Magazine 2/ x 10 CP AA180A x 1 CP HGB180A x x x x 1 CP HDA180A x 1 CP HVG180A x x x x x 1 CP HIE5A x x 1 CP BI180A x x x x 1 CP BOD180A x x x x 1 CP BOD270A x 1 CP BI120A x x 1 CP BI70A x x x 1 CP BI24A x 1 CP BI12A x x x x x 1 ComProtect For LSA-PLUS NT and LSA PROFIL NT modules NTL A10 180A x 10 NTL A8 180A x 8 NTP DA180A x 1 NTP GB180A x x x x 1 Inverted circuit configuration for installation in distributor block on the system side, since the disturbance is expected from the jumper side Number of protected pairs w w w. a d c k r o n e. c o m ( 0 )

13 Technical Reference System Overview Telecommunication Data MCRS 02 / BE P ro t e c t i o n S y s t e m s Recommended applications Operating voltage Operating current Transmission rate Analoge Lines ISDN S 0 -interface ISDN S2M-interface PMXA primary multiplexer connection PCM (without remote power feeding) PCM (with remote power feeding) PCM11 (with sym. remote power feeding) Modem for telephone line Modem for Datex P ADSL transmission RS 232 RS 485 Ethernet (CAT5) Token ring TTL-Level TTY-Level Status display 160 V 42 V 100 V 60 V 5 V 100 V 320 V 60 V 12 V 160 V 12 V 12 V 5 V 5 V 5 V 24 V 24 V < 100mA < 60 ma < 120 ma < 60 ma < 60 ma < 60 ma < 60 ma < 60 ma < 60 ma < 120 ma < 20 ma < 20 ma < 20 ma < 20 ma < 20 ma < 20 ma < 20 ma 4 khz 192 kbit/s 2 Mbit/s 2 Mbit/s 2 Mbit/s 2 Mbit/s 2 Mbit/s 64 kbit/s 48 kbit/s 8 Mbit/s 20 kbit/s 2 Mbit/s 100 Mbit/s 16 Mbit/s 64 kbit/s 64 kbit/s 64 kbit/s ComProtect Cat. number For LSA-PLUS NT and LSA PROFIL NT modules NTP VG180A x x x x x 1 NTP I180A x x x x 1 NTP OD180A x x x x 1 ComProtect For HIGHBAND 10 modules Magazine 10 DA x 10 HBP I210A1 x 1 ComProtect For MDF 71 Magazine 71/5 AT x 5 Magazine 71/4 AT x 4 Magazine 71/5 ATS x 5 Magazine 71/4 ATS x 4 71/1 CPP71 S x x x x 1 71abs/1 OD180A x x 1 ComProtect Mini-distributor ComGuard OD180A x x x x 2 Mini-distributor x 2 Mini-distributor x 6 LSA-PLUS DIRECT Integrated overvoltage protection OD180A x x x x 8 For RJ45 interface ComGuard OD180A1-RJ x x x x 2 Inverted circuit configuration for installation in distributor block on the system side, since the disturbance is expected from the jumper side Number of protected pairs Technical Reference w w w. a d c k r o n e. c o m ( 0 )

14 Technical Reference System Overview ComProtect protection plugs for LSA-PLUS and LSA PROFIL 1-, 8- and 10-pair solutions In applications in which valuable electronic equipment is used, simple three-point protection with overvoltage arrestors is not sufficient. Although overvoltage arrestors are in many cases essential components, the systems may require additional secondary protection. Such applications require highly flexible and efficient protection such as that offered by the modular ComProtect protection plugs. Technical Reference 02 / BE P ro t e c t i o n S y s t e m s Features Three- and five-point protection One-, eight- and ten-pair design assures flexible equipping of modules Support partial protection and retrofitting High-voltage, secondary, current and graded protection can be selected to meet specific requirements Additional measuring and disconnection points of various protection plugs enable work on the line without interrupting protection functions Compact design allows jumpering work on the distributor without removal of the protection components ComProtect solutions for LSA-PLUS and LSA PROFIL installations are installed after the necessary connection work has been completed. The earth bar, designed for eight or ten pairs, is fitted parallel to the module s cabling where interference is anticipated. Low resistance connection to back mount frames or profile rods are provided by the earth bar s forked contacts and/or by earth contact clips. (Profile rod frames should also be grounded separately.) The ComProtect earth bar features one contact guide for each pair; when the ComProtect protection plug is inserted into the module, its mating groove makes contact with the guide. This patented technology ensures optimum functionality and safety. The conductive contact between the protection plug s earth clip (earth contact of the protective circuit) and the earth bar is ensured during installation. In the LSA PROFIL system, additional earth clips must be installed in order to ensure a conductive contact (earth contact) between the earth bar and the profile mounting rods. Magazines for LSA-PLUS, LSA PROFIL and Main Distribution Frames (MDF 71) ADC KRONE s product portfolio includes various magazines for overvoltage protection. In addition to LSA-PLUS and LSA PROFIL distribution systems, magazines are available for MDF 71 and other related installations (drop wire and PCB modules). Various magazines are available for protection in the MDF 71 system. Typical three-point protection is implemented in the magazines; the protective components are connected to a common central connection (earth potential) when installed in the magazine. Overvoltage arrestors serve as protective components. They offer high energy absorption and very low capacitance values. In special cases, magazines can also be fitted with polycrystalline overvoltage protection components. Magazines can be particularly improved by installing fail-safe contacts in addition to the overvoltage arrestors. In the case of magazines for overvoltage protection in the LSA-PLUS distribution system, fail-safe contacts (thermal protection springs) can be simply plugged in, hence connecting them parallel to the two-electrode arrestors, or are just integrated onto the three-pole arrestors. If the arrestor overheats as a result of overvoltage, a solder material melts, triggering the fail-safe function to generate a short-circuit to earth parallel to the arrestors, hence discharging any subsequent currents. The same effect is achieved in other magazines (71/4 and 71/5) by installing fail-safe rings that close when the arrestors overheat, melting a prestressed fail-safe contact. w w w. a d c k r o n e. c o m ( 0 )

15 Technical Reference System Overview Three-electrode arrestors with optional fail-safe contacts are available for LSA-PLUS, LSA PROFIL and MDF 71 magazines. After the distribution system has been installed, all connection work is then carried out. Only when a low-resistance connection between rack frame and central earth bar and/or earth rod is established does the distribution frame provide an earth potential for the overvoltage protection components. The magazines are already equipped with earth contacts that, when installed, ensure a low-resistance path between rack frame and protection components. After the overvoltage arrestors and optional fail-safe contacts have been fitted, the magazines are inserted into the distributor module. Magazines for the MDF 71 (71/4 and 71/5) are inserted into the appropriate lateral contact insert (subscriber side) of the distributor element of the MDF 71. Technical specifications 02 / BE P ro t e c t i o n S y s t e m s The following technical specifications and dimensions of the ComProtect products have been complied for the standard offering of one-pair protection components. Transmission behaviour Magazines Series MDF 71 ComProtect A Series ComProtect B Series ComProtect H Series ComProtect NTP Series Jumpering ability ++ +(+) +(+) Line protection Reversible current protection Partial/ combined fitting Fail-safe Secondary protection High voltage protection = Very good +(+) = Good (or optional very good) Technical Reference w w w. a d c k r o n e. c o m ( 0 )

16 Technical Reference System Overview Technical Data Technical Reference Technical Data w w w. a d c k r o n e. c o m ( 0 )

17 Technical Reference System Overview Technical Data ComProtect NTP / types 180A1 OD180A2 GB180A2 GB180C1 DA180A1 VG180C1 AS180A1 Unit Operating voltage (DC/AC): <180/127 <180/127 <180/127 <180/127 <180/127 <180/127 <180/127 V/Vrms Operating current at +25 C: <120 <70 <130 < < MA Protection level at 100V/sec: <290 <240 <290 <290 <290 <290 <290 V Protection level at 1KV/ µs: <350 <240 <700 <700 <800 <700 <300 V Nominal surge current 8/20µs: KA Nominal alternating discharge current 50Hz1: Resistance (passive temperature resistors): Trip time (passive temperature) at 500mA/25 C: Arms <1 W <10 <20 <10 <1.5 - <20 - s Fail-safe response time at 5Arms: <5 - <5 <5 <5 <5 <5 s Capacity at 1MHz/1Vac: <5 5 <20 pf Leakage current1 : <5 <5 <0.1 <0.1 <0.1 <0.1 <0.1 µa Attenuation loss at Z0=600Ω: <0.3 <0.7 <0.3 <0.1 <0.1 <0.3 <0.1 DB Operating temperature: Storage temperature: Environmental conditions: Electrical characteristics: Electrical safety: -20 C to +60 C -40 C to +80 C IEC 721 part 3-3: 3K6, 3Z2, 3B1, 3C2, 3S1, 3M3 ITU-T K.11, DIN EN category C2 and C3 According to EN :2001, CE-Marking Technical Reference w w w. a d c k r o n e. c o m ( 0 )

18 Technical Reference 02 / Protection Systems w w w. a d c k r o n e. c o m ( 0 )

19 LSA-PLUS and LSA PROFIL Modules LSA-PLUS and LSA PROFIL NT Modules LSA-PLUS DIRECT Module HighBand 10 Modules Main Distribution Frame Flex MDF-Block Mini-distributors Test Device for Protection Components ComProtect Overvoltage Protection 15

20 LSA-PLUS and LSA PROFIL Modules Basic Protection Magazine for LSA-PLUS Series 2 Blocks This basic protection magazine is recommended for use as a basic overvoltage protection in analog and digital telecommunication systems. The magazines are designed for the complete equipping of LSA-PLUS or LSA PROFIL disconnection or connection modules. For installation in LSA PROFIL distributors, earth contact clips are required to establish earth contact with the profile rods. Optimal function for magazines is guaranteed only when used in conjunction with the corresponding overvoltage arrestors. For information on 2-pole overvoltage arrestors (gas discharge tubes), see the basic protection magazine for MDF 71, found on page 43 Comprotect Overvoltage Protection Features Designed for use with 2- or 3-pole overvoltage arrestors Overvoltage arrestors and fail-safe elements are replaceable Installation height is approximately 25 mm above the LSA-PLUS or LSA PROFIL module Ordering information appears on the following page. Magazine 2/10 for 3-pole gas discharge tubes (GDT) 16

21 LSA-PLUS and LSA PROFIL Modules Description Weight/Pack Catalogue Number Basic protection magazine for 8-pairs with 3-pole overvoltage arrestors (8x13 mm) Quantity: 1 per pack, Installation 25 mm above module Magazine 2/8 for 8-pair modules, unequipped kg Magazine 2/8 for 8-pair modules, equipped with overvoltage arrestors (8x13 mm), 230V, 10kA/10A with fail-safe ( ) Basic protection magazine for 10-pairs with 3-pole overvoltage arrestors (8 x 13 mm) Quantity: 1 per pack kg Magazine 2/10 for 10-pair modules, unequipped kg Magazine 2/10 for 10-pair modules, equipped with overvoltage arrestors (8x13 mm), 230V, 10kA/10A with fail-safe ( ) Basic protection magazine for 8-pairs with 2-pole overvoltage arrestors (8x6 mm) Quantity: 1 per pack kg Magazine 2/8 for 8-pair modules, unequipped kg Magazine 2/8 for 8-pair modules, equipped with 2-pole overvoltage arrestor (8x6 mm) (metal/ceramic), 90V, 20kA/20A ( ) and fail-safe contact ( ) Magazine 2/8 for 8-pair modules, equipped with 2-pole overvoltage arrestors (8x6 mm; metal/ceramic), 230V, 5kA/5A ( ) and fail-safe contact ( ) Basic protection magazine for 10-pairs with 2-pole overvoltage arrestors (8x6 mm) Quantity: 1 per pack kg kg Magazine 2/10 for 10-pair modules, unequipped kg Magazine 2/10 for 10-pair modules, equipped with 2-pole overvoltage arrestor (8x6 mm; metal/ceramic), 230V, 10kA/10A ( ) and fail-safe contact ( ) Magazine 2/10 for 10-pair modules, equipped with 2-pole overvoltage arrestor (8x6 mm; metal/ceramic), 230V, 5kA/5A ( ) and fail-safe contact ( ) kg kg ComProtect Overvoltage Protection 17

22 LSA-PLUS and LSA PROFIL Modules 3-Pole Overvoltage Arrestors The 3-pole overvoltage arrestor (metal/ceramic) is filled with noble-gas and features optional fail-safe (type 8x13) and offers effective 3-point protection for the most varied applications. For 10-pairs, ten overvoltage arrestors are required. Features Reliable limitation of overvoltages Diversion of high currents Thermal protection by means of fail-safe Comprotect Overvoltage Protection 3-pole overvoltage arrestors without fail-safe Description Catalogue Number 3-pole overvoltage arrestors (8x13 mm) Quantity: 1 per pack Weight/Pack: kg 230V, 10kA/10A, without fail-safe V, 10kA/10A, without fail-safe V, 20kA/10A, with fail-safe V, 10kA/10A, with fail-safe V, 10kA/10A, with fail-safe Fail-Safe Contact These elements are used in conjunction with the 2-pole overvoltage arrestors (gas discharge tubes, GDT), type 8x6 mm, which are installed in the basic protection magazines 2/10 or 2/8 for LSA-PLUS blocks. Their functionality is only guaranteed when they are used in conjunction with metal/ceramic overvoltage arrestors. In the case of thermal overload (which triggers the fail-safe contact), both the overvoltage arrestor and the fail-safe contact must be replaced. Features Protection against long-term thermal overload Replaceable component Description Catalogue Number Fail-safe contact Quantity: 1 per pack Weight/Pack: kg

23 LSA-PLUS and LSA PROFIL Modules Magazine Cover The magazine cover is transparent and is used with overvoltage protection magazine 2/10 with gas discharge tube (GDT), 8x6 or 8x13. Features Provides dust protection Prevents accidental contact with the overvoltage protection magazine Description Catalogue Number Magazine cover Quantity: 1 per pack Weight/Pack: kg With KRONE logo Without KRONE logo ComProtect Overvoltage Protection 19

24 LSA-PLUS and LSA PROFIL Modules Basic Protection Magazine for LSA-PLUS Series 8 Blocks This basic protection magazine is recommended for use as basic overvoltage protection in analog telecommunications systems. For basic protection, 2-pole overvoltage arrestors (gas discharge tubes, GDTs) 8x6mm, as well as optional fail-safe contacts can be installed. For information on 2-pole overvoltage arrestors, see the basic protection magazine for MDF 71, found on page 43. Features Enables individual configuration of number of protected pairs Comprotect Overvoltage Protection Ordering information appears on the following page. 2-pair magazine for 2-pole overvoltage arrestors 6-pair magazine for 2-pole overvoltage arrestors 10-pair magazine for 2-pole overvoltage arrestors 20

25 LSA-PLUS and LSA PROFIL Modules Description Weight/Pack Catalogue Number Basic protection magazine for Series 8 modules, 2-pairs (8/2) Quantity: 1 per pack Magazine 8/2, unequipped 0.014kg Magazine 8/2, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 20kA/20A, fail-safe contact ( ) Magazine 8/2, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 20kA/20A Magazine 8/2, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 10kA/10A Magazine 8/2, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 5kA/5A, fail-safe contact ( ) Basic protection magazine for Series 8 modules, 6-pairs (8/6) Quantity: 1 per pack 0.020kg kg kg kg Magazine 8/6, unequipped 0.038kg Magazine 8/6, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 20kA/20A, fail-safe contact ( ) Magazine 8/6, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 20kA/20A Magazine 8/6, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 10kA/10A Magazine 8/6, equipped with overvoltage arrestors (8x6 mm; metal/ceramic), 230V, 5kA/5A, fail-safe contact ( ) Basic protection magazine for Series 8 modules, 10-pairs (8/10) Quantity: 1 per pack 0.056kg kg kg kg Magazine 8/10, unequipped 0.055kg Magazine 8/10, equipped with overvoltage arrestors (8x6mm; metal ceramic), 230V, 20kA/20A, fail-safe contact ( ) Magazine 8/10, equipped with overvoltage arrestors (8x6mm; metal ceramic), 230V, 20kA/20A Magazine 8/10, equipped with overvoltage arrestors (8x6mm; metal/ceramic), 230V, 10kA/10A Magazine 8/10, equipped with overvoltage arrestors (8x6 mm; metal/ceramic), 230V, 5kA/5A, fail-safe contact ( ) 0.091kg kg kg kg ComProtect Overvoltage Protection 21

26 LSA-PLUS and LSA PROFIL Modules Basic Protection Plugs for LSA-PLUS Series 2 Blocks These plugs are recommended for use as basic overvoltage protection in analog telecommunication systems. The plugs are designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL connection or disconnection modules in conjunction with earth bars and earth contact clips. Jumpering can be performed in a protected distributor module. The protection circuit consists of highly effective 2- or 3-pole overvoltage arrestors and fail-safe contacts for protection of the arrestors against thermal overload. Comprotect Overvoltage Protection Features Compact form Flexible 1-pair design Jumpering is possible with protection inserted Basic protection plug (ComProtect A) Description Weight/Pack Catalogue Number Basic protection plug for LSA-PLUS Series 2 blocks, 1-pair Installation 21 mm above block Quantity: 10 pieces per pack, including 1 earth bar 2/10 Plug marking: CP AA180A kg pole overvoltage arrestors Maximum operating voltage: 180V Plug marking: CP AA280A kg pole overvoltage arrestors Maximum operating voltage: 280V Plug marking: CP HDA180A1 3-pole overvoltage arrestors Maximum operating voltage: 180V Installation 33 mm above block Quantity: 10 pieces per pack, including 1 earth bar 2/ kg

27 LSA-PLUS and LSA PROFIL Modules Intermediate Protection Plugs for LSA-PLUS Series 2 Blocks This plugs are recommended for protection of switching and terminal equipment in conjunction with already installed secondary overvoltage protection. The use of reversible overcurrent protection elements can enhance the response behaviour of the basic overvoltage protection component. The plug is designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL connection or disconnection modules in conjunction with earth bars and earth contact clips. The protection circuit consists of a 3-pole overvoltage arrestor, fail-safe and overcurrent protection components. An insertion tool ( ) is used to allow jumpering in the protected distributor module. Features Flexible 1-pair form Limits overvoltage and overcurrents Jumpering is possible with inserted protection Provides measurement and test access Installation height is approximately 33 mm above the LSA-PLUS or LSA PROFIL module Intermediate protection plug (ComProtect H) Description Weight/Pack Catalogue Number Intermediate protection plug for LSA-PLUS Series 2 blocks, 1-pair Installation 33 mm above block Plug marking: CP HGB180A kg Maximum operating voltage: 180V, nominal restistance 8 Ohm Quantity: 10 pieces per pack, including 1 earth bar 2/10 Plug marking: CP HGB180A kg Maximum operating voltage: 180V, nominal restistance 8 Ohm resistance balance <1.5 Ohm Quantity: 10 pieces per pack, including 1 earth bar 2/10 Plug marking: CP HGB180A kg Maximum operating voltage: 180V, nominal resistance 30 Ohm Quantity: 10 pieces per pack, including 1 earth bar 2/10 Plug marking: CP HVG180A kg Maximum operating voltage: 180V, resistance balance: 1 Ohm. Inverted circuit configuration for installation in distributor block on the system side, as disturbance is expected from the jumper side Quantity: 10 pieces per pack, including 1 earth bar 2/10 Plug marking: CP HVG180A2 Maximum operating voltage: 180V, nominal resistance 8 Ohm. Inverted circuit configuration for installation in distributor block on the system side, as disturbance is expected from the jumper side Quantity: 10 pieces per pack, including 1 earth bar 2/ kg ComProtect Overvoltage Protection 23

28 LSA-PLUS and LSA PROFIL Modules Data Protection Plug for LSA-PLUS Series 2 Blocks This plug is recommended for unshielded cabling in data transmission networks. The plug is designed for partial or complete equipping of LSA-PLUS or LSA PROFIL disconnection or switching modules in conjunction with earth bars and earth contact clips. An insertion tool ( ) is used to allow jumpering in the protected distributor module. Comprotect Overvoltage Protection Features Flexible 1-pair form Designed for use in networks with high transmission rates Short response times Installation height is approximately 33 mm above the LSA-PLUS or LSA PROFIL module Data protection plug Description Weight/Pack Catalogue Number Data protection plug for LSA-PLUS Series 2 blocks Plug marking: CP HIE4A1 Maximum operating voltage: 5V, Quantity: 10 pieces per pack, including 1 earth bar 2/10 Installation 33 mm above block kg

29 LSA-PLUS and LSA PROFIL Modules Current Protection Plug for LSA-PLUS Series 2 Blocks This plug is used when permanent network influences render pure basic protection insufficient. The 1-pair overcurrent plug s (HPP_A2) modular design is used for the partial or complete equipping of LSA-PLUS or LSA PROFIL disconnection or switching modules. It is used as a pure overcurrent protection component, primarily in distribution equipment that is already equipped with overvoltage arrestors. ADC KRONE strongly recommends use of a combination of HHP_A2 and basic protection (ComProtect or overvoltage protection magazines). Features Flexible 1-pair form Provides extension of already installed protection Jumpering is possible with inserted protection Installation height is approximately 33 mm above LSA-PLUS or LSA PROFIL modules Description Weight/Pack Catalogue Number Current protection plug for LSA-PLUS Series 2 blocks Plug marking: HPP A2 Maximum operating voltage: 5V, Quantity: 10 pieces per pack, including 1 earth bar 2/10 Installation 33 mm above block Current protection plug kg ComProtect Overvoltage Protection 25

30 LSA-PLUS and LSA PROFIL Modules Accessories for Intermediate Protection Plugs Comprotect Overvoltage Protection Test cord for intermediate protection plugs; Description Weight/Pack Catalogue Number Test cord for intermediate protection plugs Enables 2-pole measuring and testing for parallel add-on connections; inserts directly at the protection plug s measuring points Quantity: 1 per pack Length: 1.5 m Jumpering tool For system-side jumpering and wiring work on LSA-PLUS or LSA PROFIL modules with inserted ComProtect primary and overcurrent protection plugs. Quantity: 1 per pack (NOTE: one tool included in every pack of 100 protection plugs) Jumper wire conductor diameter range: 0.5 to 0.6 mm Jumper outer diameter range: 0.9 to 1.2 mm Jumpering tool kg kg

31 LSA-PLUS and LSA PROFIL Modules Advanced Protection Plugs for LSA-PLUS Series 2 Blocks These plugs are recommended for protection of distribution and terminal equipment in analog, ISDN, HDSL and ADSL telecommunication systems. The plug is designed for partial or complete equipping of LSA-PLUS or LSA PROFIL disconnection or switching modules in conjunction with earth bars and earth contact clips. Jumpering of distribution modules with inserted protection components is possible. The protection circuit consists of a 3-pole overvoltage arrestor, fail-safe contact, reversible overcurrent protection components and diodes for secondary protection. Features Flexible 1-pair form Short response time Jumpering is possible with inserted protection Low-voltage variants are available for extended applications Installation height is approximately 21 mm above the LSA-PLUS or LSA PROFIL module Advanced protection plug Description Weight/Pack Catalogue Number Advanced protection plug for LSA-PLUS Series 2 blocks, 1-pair Protection circuit consists of 3-pole overvoltage arrestor, failsafe contact, reversible overcurrent protection components, diodes for secondary protection Quantity: 10 per pack, including 1 earth bar 2/10 Installation 21 mm above block Plug marking: CP BI180A kg Maximum operating voltage: 180V Plug marking: CP BI120A kg Maximum operating voltage: 120V For ISDN Uk 0 and S2M interfaces Plug marking: CP BI70A kg Maximum operating voltage: 70V For measurement and control technology and industrial bus applications Plug marking: CP BI24A kg Maximum operating voltage: 24V For measurement and control technology and industrial bus applications Plug marking: CP BI12A1 Maximum operating voltage: 12V For measurement and control technology and industrial bus applications kg ComProtect Overvoltage Protection 27

32 LSA-PLUS and LSA PROFIL Modules Maintenance-Free Protection Plug for LSA-PLUS Series 2 Blocks This plug is recommended for protection of distribution and terminal equipment in analog, ISDN, HDSL and ADSL telecommunications systems. The plug is designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL disconnection or switching modules in conjunction with earth bars and earth contact clips. Jumpering of distribution modules with inserted protection components is possible. The protection circuit consists of a 3-pole overvoltage arrestor, reversible overcurrent protection components and diodes for secondary overvoltage protection. The overcurrent protection functions as a reversible line fuse. Comprotect Overvoltage Protection Features Flexible 1-pair form Fast response times Jumpering is possible with inserted protection Optimised service life-time Installation height is approximately 21 mm above the LSA-PLUS or LSA PROFIL module Maintenance-free protection plug Description Weight/Pack Catalogue Number Maintenance-free protection plug for LSA-PLUS Series 2 blocks, 1-pair Quantity: 10 per pack, including 1 earth bar 2/10 Installation 21 mm above block Plug marking: CP BOD180A kg Maximum operating voltage: 180V Plug marking: CP BOD270A1 Maximum operating voltage: 270V Used with PCM11 transmission codes with symmetric remote feeding voltage 320V kg

33 LSA-PLUS and LSA PROFIL Modules Earth Plug for LSA-PLUS Series 2 Blocks The earth plug is used for permanent earthing of single pairs in LSA-PLUS or LSA PROFIL disconnection, connection and switching modules. The plug is installed in conjunction with earth bars and earth contact clips. Features Flexible 1-pair form Surge-current-proof design Can be used with any module Earth plug Description Weight/Pack Catalogue Number Earth plug for LSA-PLUS Series 2 blocks, 1-pair Plug marking: CP GZA1 Quantity: 10 per pack, including 1 earth bar 2/ kg ComProtect Overvoltage Protection 29

34 LSA-PLUS and LSA PROFIL Modules Earth Bars for LSA-PLUS Modules Comprotect Overvoltage Protection Earth bar for Series 2 and HighBand 10 modules Earth bar for disconnection module 2/8 x abs Earth bar for disconnection module 2/6 x abs Earth contact clip The earth bar is used to establish earth connection between ComProtect protection plugs and LSA-PLUS modules installed in a distribution frame. Installation in an LSA PROFIL distribution frame requires the additional installation of earth contact clips. WARNING: Proper function of the protection plugs is not guaranteed without use of the earth bar. Installation instructions must be followed. Description Weight/Pack Catalogue Number Earth bar for LSA-PLUS Series 2 and HighBand 10 blocks Quantity: 1 per pack NOTE: a set of 10/100 ComProtect protection plugs includes 1/10 earth bars Earth bar for 10-pair modules kg Earth bar for 8-pair modules kg Earth bar for LSA-PLUS Series 2 disconnection module, 6 x Line A, Line B, Shield (abs) Quantity: 1 per pack Earth bar for LSA PROFIL Series 2 disconnection module, 8 x Line A, Line B, Shield (abs) Quantity: 1 per pack Earth contact clip for LSA PROFIL Series 2 modules provides contact between earth bar and profile rod. 2 clips required per module when protection modules are used with Series 2 modules mounted on 12 mm profile rods. Quantity per box: kg kg kg

35 LSA-PLUS and LSA PROFIL NT Modules Basic Protection Magazine for LSA-PLUS NT Modules This magazine is recommended for basic overvoltage protection in analog or digital telecommunication systems. The magazine is equipped with 3-pole overvoltage arrestors (gas discharge tubes). Magazines with maximum operating voltages of 180V are equipped with a fail-safe contact. The magazine is designed for the complete equipping of LSA-PLUS or LSA PROFIL NT connection, disconnection or switching modules. 10-pair NT magazine with 3-pole overvoltage arrestors (gas discharge tubes) Description Weight/Pack Catalogue Number Basic protection magazine for LSA-PLUS NT modules Quantity: 1 per pack Installation 29.5 mm above module For 10-pair NT modules (NTL A10 180A1) maximum operating voltage: 180V kg Overvoltage arrestors: 230V, 5kA/5A and fail-safe (NTL A10 330A1) maximum operating voltage: 330V kg Overvoltage arrestors: 420V, 5kA/5A For 8-pair NT modules (NTL A8 180A1) maximum operating voltage: 180V kg Overvoltage arrestors: 230V, 5kA/5A and fail-safe (NTL A8 330A1) maximum operating voltage: 330V Overvoltage arrestors: 420V, 5kA/5A kg ComProtect Overvoltage Protection 31

36 LSA-PLUS and LSA PROFIL NT Modules Basic Protection Plug for LSA-PLUS NT Modules This plug provides basic overvoltage protection in analog or digital telecommunication systems. The plug is designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL NT disconnection or switching modules and is used in conjunction with an 8- or 10-pair earth bar. The protective circuit consists of a 3-pole overvoltage arrestor and fail-safe contact (for protection of the arrestor against thermal overload). Comprotect Overvoltage Protection Features Compact form Flexible 1-pair design Installation height is approximately 32 mm above the LSA-PLUS or LSA PROFIL NT module Basic protection plug Description Weight/Pack Catalogue Number Basic protection plug for LSA-PLUS NT modules Plug marking: NTP DA180A1 Maximum operating voltage 180V Quantity: 10 per pack, including 1 earth bar NTP/10 Installation 32 mm above module kg

37 LSA-PLUS and LSA PROFIL NT Modules Intermediate Protection Plugs for LSA-PLUS NT Modules There plugs are recommended for protection of switching and terminal equipment in conjunction with already installed secondary overvoltage protection. The plug is designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL NT disconnection or switching modules and is used in conjunction with an 8- or 10-pair earth bar. The protective circuit consists of a 3-pole overvoltage arrestor (gas discharge tube), fail-safe contact and reversible overcurrent protection components. Features Flexible 1-pair form Limits both overvoltages and overcurrents Inverted circuit configurations Installation height is approximately 32 mm above the LSA-PLUS or LSA PROFIL NT module Description Intermediate protection plug for LSA-PLUS NT modules Maximum operating voltage: 180V Quantity: 10 per pack, including 1 earth bar NTP/10 Weight/pack: kg Installation mm above module Plug marking: NTP GB1180A2 Overvoltage protection with 10-Ohm ceramic PTC Plug marking: NTP GB180C1 Overvoltage protection with 6-Ohm polymer PTC Plug marking: NTP VG180C1 Overvoltage protection with 6-Ohm polymer PTC. Inverted circuit configuration for system-side installation in distributor block, as disturbance is expected from jumper side Intermediate protection plug Catalogue Number ComProtect Overvoltage Protection 33

38 LSA-PLUS and LSA PROFIL NT Modules Advanced Protection Plug for LSA-PLUS NT Modules This plug is recommended for protection of switching and terminal equipment in analog, ISDN, HDSL and ADSL telecommunication systems. The plug is designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL NT disconnection or switching modules and is used in conjunction with an 8- or 10-pair earth bar. the protection circuit consists of a 3-pole overvoltage arrestor (gas discharge tube), fail-safe contact, reversible overcurrent protection components and diodes for secondary protection. Features Flexible 1-pair form Short response times Installation height is approximately 32 mm above the LSA-PLUS or LSA PROFIL NT module Comprotect Overvoltage Protection Description Advanced protection plug for LSA-PLUS NT modules Plug marking: NTP I180A1 Maximum operating voltage: 180V Weight/pack: kg Installation 32 mm above module Quantity: 10 per pack, including 1 earth bar NTP/10 Advanced protection plug Catalogue Number

39 LSA-PLUS and LSA PROFIL NT Modules High-Speed Data Protection Plug for LSA-PLUS NT Modules This plug is recommended for unshielded cabling in data transmission networks up to 100Mbps. The plug is designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL NT disconnection or switching modules in conjunction with an 8 or 10-pair earth bar. The protection circuit consists of a 3-pole overvoltage arrestor (gas discharge tube), fail-safe and diodes for secondary protection High-speed data protection plug Description High-speed data protection plug for LSA-PLUS NT modules Plug marking: NTP AS180A1 Maximum operating voltage: 180V Weight/pack: kg Quantity: 10 per pack, including 1 earth bar NTP/10 Insertion loss (300 Hz to 100 khz at 600Ω): <0.1dB Return loss (300 Hz to 100 khz at 600Ω): >20dB Longitudinal conversion loss > 1 khz: >60dB 1 khz to 10 khz: >55dB 10 khz to 100 khz: >50dB Catalogue Number ComProtect Overvoltage Protection 35

40 LSA-PLUS and LSA PROFIL NT Modules Maintenance-Free Protection Plug for LSA-PLUS NT Modules This plug is recommended for protection of distribution and terminal equipment in analog, ISDN, HDSL and ADSL telecommunications systems. The plug is designed for the partial or complete equipping of LSA-PLUS or LSA PROFIL NT disconnection or switching modules and is used in conjunction with an 8- or 10-pair earth bar. The protection circuit consists of a 3-pole overvoltage arrestor, fail-safe contact, reversible overcurrent protection components and diodes for secondary overvoltage protection. The overcurrent protection functions as a reversible line fuse. Features Flexible 1-pair form Short response times Optimised service life-time Installation height is approximately 32 mm above the LSA-PLUS or LSA PROFIL NT module Comprotect Overvoltage Protection Description Maintenance-free protection plug for LSA-PLUS NT modules Plug marking: NTP OD180A2 Maximum operating voltage: 180V Weight/pack: kg Installation 32 mm above module Quantity: 10 per pack, including 1 earth bar NTP/10 Maintenance-free protection plug Catalogue Number

41 LSA-PLUS and LSA PROFIL NT Modules Accessories for LSA-PLUS and LSA PROFIL NT Module Overvoltage Protection Earth bar Description Weight/Pack Catalogue Number Earth bar for LSA-PLUS NT modules Earth contact for 1-pair NTP series ComProtect protection plugs; used to establish earth contact between the protection plugs and the distribution frame WARNING: The function of the protection plug is only guaranteed in conjunction with the earth bar. The installation instructions must be followed. Quantity: 1 per pack NOTE: 1 earth bar NTP/10 and NTP18 are included with every set of NTP ComProtect protection plugs Jumpering tool For 10-pair LSA-PLUS NT modules kg For 8-pair LSA-PLUS NT modules kg Jumpering tool For jumpering on a free pair of LSA-PLUS or LSA PROFIL NT module, installed with a width (pitch) of 17.5 mm and equipped with 1-pair NT protection plugs Quantity: 1 per pack Jumper wire conductor diameter range: 0.5 to 0.6 mm Jumper outer diameter range: 0.9 to 1.2 mm kg ComProtect Overvoltage Protection 37

42 LSA-PLUS DIRECT Module Integrated Maintenance-Free Protection LSA-PLUS DIRECT Module Comprotect Overvoltage Protection Features Integrated, maintenance-free protection circuit Allows disconnection, measurement and testing Features D-subminiature connector for use of preconfigured cables Optimised service life Installation depth is approximately 72 mm from the profile rods Ordering information appears on the following page. Front view of LSA-PLUS DIRECT Label holder The maintenance-free protection in the LSA-PLUS DIRECT module supports its use as a protection unit for decentralised, outside plant digital switching equipment. The module is installed on the system side in the distribution area on a profile rod frame with a centre-tocentre rod distance of 75 mm. The integrated maintenance-free protection circuit allows unrestricted front access for disconnection, measurement and jumpering activities. The protection circuit consists of 3-pole overvoltage protection components, as well as diodes for secondary overvoltage protection. The D- subminiature connector on the back allows for termination of preconfigured cables for direct connection with system components. The LSA-PLUS insertion tool terminates individual contacts. Rear view 38

43 LSA-PLUS DIRECT Module Description Weight/Pack Catalogue Number LSA-PLUS DIRECT module with maintenance-free protection Maximum operating voltage: 180V LSA-PLUS DIRECT module with basic protection Maximum operating voltage: 350V Accessories Label holder Includes paper label and transparent cover Colour: Grey kg kg kg ComProtect Overvoltage Protection 39

44 HighBand 10 Modules ADSL Protection for HighBand 10 Modules The protection magazine for the HighBand 10 modules is recommended as basic overvoltage protection in analog telecommunication systems. The magazine completely equips HighBand 10 disconnection modules. To establish an earth contact, the magazine requires the use of earth contact clips (see page xx) when it is installed in an LSA PROFIL distribution frame. If unequipped magazines are ordered, corresponding overvoltage arrestors (GDT) must be ordered to guarantee optimal performance. Comprotect Overvoltage Protection Features Overvoltage arrestors and fail-safe contacts are replaceable Accepts three-pole overvoltage arrestors Installation height is approximately 25mm above the HighBand 10 module ADSL protection magazine The protection plug is recommended for protection of switching and terminal equipment in analog, ISDN, HDSL and ADSL telecommunication systems. The plug is designed for the partial or complete equipping of HighBand 10 disconnection modules and is used in conjunction with an earth bar and earth contact clips. The protection circuit consists of a 3-pole overvoltage arrestor (gas discharge tube), fail-safe contact, reversible overcurrent protection components and diodes for secondary overvoltage protection. Features Flexible 1-pair form Short response times Suitable for use in networks with high transmission rates Installation height is approximately 21 mm above the HighBand 10 module ADSL protection plug Description Catalogue Number ADSL protection magazine for HighBand 10 modules For 10-pair modules; overvoltage arrestors ordered separately Weight/pack: 0.037kg Quantity: 1 per pack ADSL protection plug for HighBand 10 modules Plug marking: HBP I210A1 Maximum operating voltage: 210V Weight/pack: kg Installation 21 mm above module Quantity: 10 per pack, including 1 earth bar NTP/10 Earth bar Earth contact clip

45 Main Distribution Frame 71 Basic 5-Pair Protection Magazine for the MDF 71 This magazine is recommended for basic overvoltage protection in analog telecommunication systems. The 5-pair overvoltage protection magazine can be ordered equipped with 2-pole overvoltage arrestors and fail-safe elements for installation in the MDF 71. Features Can be used with 2-pole and 3-pole overvoltage arrestors The overvoltage arrestors and fail-safe elements are replaceable 5-pair magazine overvoltage arrestor and fail-safe element Description Weight/Pack Catalogue Number Basic 5-pair protection magazine for the MDF 71 Quantity: 1 per pack With 2-pole overvoltage arrestors (8x6mm) and fail-safe elements Magazine 71/5, unequipped kg Magazine 71/5 AT, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic), 230V, 20kA/20A Magazine 71/5 AT, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic), 230V, 10kA/10A Magazine 71/5 AT, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic), 230V, 5kA/5A Magazine 71/5 A/T, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic), 350V, 20kA/20A Magazine 71/5 AT, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic), 350V, 5kA/5A With 2-pole overvoltage arrestors (8x6mm), no fail-safe elements Magazine 71/5, unequipped kg Magazine 71/5 A, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic), 230V, 20kA/20A Magazine 71/5 A, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic) 230V, 10kA/5A Magazine 71/5 A, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic) 230V 5kA/5A With 3-pole GDT-type overvoltage arrestors (8x13) and fail-safe Magazine 71/5-3, unequipped PRO Magazine 71/5-3 AT, equipped with 3-pole overvoltage PRO arrestors (8x13), 230V, 10kA/10A (a+b/earth) ComProtect Overvoltage Protection 41

46 Main Distribution Frame 71 Basic 4-Pair Protection Magazine for the MDF 71 This magazine is recommended as basic overvoltage protection in analog telecommunication systems. The 4-pair overvoltage magazine can be ordered equipped with 2-pole overvoltage arrestors and failsafe elements, for installation in the MDF 71. Features Can be used with 2-pole and 3-pole overvoltage arrestors The overvoltage arrestors and fail-safe elements are replaceable Comprotect Overvoltage Protection 5-pair magazine overvoltage arrestor and fail-safe element Description Weight/Pack Catalogue Number Basic 4-pair protection magazine for the MDF 71 Quantity: 1 per pack With 2-pole overvoltage arrestors (8x6) and fail-safe elements Magazine 71/4, unequipped kg Magazine 71/4 AT, equipped with overvoltage arrestors kg (8x6mm; metal/ceramic) 230V, 20kA/20A Magazine 71/4 AT, equipped with overvoltage arrestors kg (8x6 mm; metal/ceramic) 230V, 10kA/10A Magazine 71/4 AT, equipped with overvoltage arrestors kg (8x6 mm; metal/ceramic) 23V, 5kA/5A With 2-pole overvoltage arrestors (8x6), no fail-safe elements Magazine 71/4, unequipped Magazine 71/4 A, equipped with overvoltage arrestors kg (8x6 mm; metal/ceramic) 230V, 20kA/20A Magazine 71/4 A, equipped with overvoltage arrestors kg (8x6 mm; metal/ceramic) 230V, 5kA/5A With 3-pole GDT-type overvoltage arrestors (8x13) and fail-safe Magazine 71/4-3, unequipped PRO Magazine 71/4-3 AT, equipped with 3-pole overvoltage arrestors (8x13), 230V, 10kA/10A (a+b/earth) PRO

47 Main Distribution Frame 71 2-Pole Overvoltage Arrestors These arrestors are used as replaceable basic protection elements. The 2-pole overvoltage arrestors (with dimensions of 8 x 6 mm) have a metal/ceramic construction. The electrical properties depend on the noble-gas mixture. In order to protect 10-pairs, 20 overvoltage arrestors must be installed. Features Reliable limitation of overvoltages Diversion of high currents Thermal protection by means of fail-safe contacts Description 2-pole overvoltage arrestors 8x6 mm, metal/ceramic Quantity: 1 per pack Weight/pack: kg Catalogue Number 90V, 20kA/20A V, 10kA/10A V, 20kA/20A V, 10kA/10A V, 5kA/5A V, 20kA/20A V, 10kA/10A Fail-safe ring for basic protection magazine For use only in conjunction with 8x6 mm metal/ceramic overvoltage arrestors. Provide protection against thermal overload in case of long-term loads Quantity: 1 per pack 2-pole overvoltage arrestors Fail-safe ring for basic protection magazine ComProtect Overvoltage Protection 43

48 Main Distribution Frame 71 3-Pole Overvoltage Arrestors The 3-pole overvoltage arrestor (metal/ceramic) is filled with noble-gas and features optional fail-safe (type 8x13) and offers effective 3-point protection for MDF 71 Features Reliable limitation of overvoltages Diversion of high currents Thermal protection by means of fail-safe Comprotect Overvoltage Protection Overcurrent Protection Plugs Installed on the front of the MDF 71, the overcurrent protection plug complements the 4- and 5-pair overvoltage protection magazines. The overcurrent protection plug can be installed in already setup distribution equipment. In conjunction with the protection magazines, it provides an enhanced intermediate protection circuit. Jumpering requires removal of the overcurrent protection plug, but should be carried out with the magazine inserted. This ensures that maintenance and installation personnel are protected during their work. Features Flexible 1-pair construction Enhancement of already installed protection Overcurrent variants 3-pole overvoltage arrestors without fail-safe Description Catalogue Number 3-pole overvoltage arrestors (8x13 mm) Quantity: 1 per pack Weight/Pack: kg 230V, 10kA/10A, without fail-safe V, 10kA/10A, without fail-safe V, 10kA/10A, with fail-safe PRO V, 10kA/10A, with fail-safe PRO V, 20kA/20A, with fail-safe PRO V, 10kA/10A, with fail-safe PRO Overcurrent protection plug element Description Overcurrent protection plug Plug marking: CPP71 S8, equipped with polymer PTC Quantity: 1 per pack Weight/pack: kg Catalogue Number

49 Main Distribution Frame 71 Maintenance-Free ADSL Protection Plugs for the MDF 71 These plugs are recommended for protection of distribution and terminal equipment in analogue, ISDN, HDSL and ADSL telecommunication systems. The plugs are designed for the partial or complete frontal equipping of MDF 71 modules (4 x abs). The maintenance-free protection circuit consists of a 3-pole overvoltage arrestor, fail-safe, reversible overcurrent protection components and diodes for secondary overvoltage protection. The overcurrent protection functions as a reversible line fuse. Features Flexible 1-pair construction Short response times Optimised service life Installation height is approximately 36mm above the MDF 71 module Description Maintenance-free ADSL protection plug for MDF 71 (4 x abs) Inverted circuit configuration for system-side installation in distributor blocks, as the disturbance is expected from the jumper side Quantity: 1 per pack Weight per pack: kg Plug markings: CP OD110B1 Maximum operating voltage: 110V Plug markings: CP OD180B1 Maximum operating voltage: 180V Maintenance-free ADSL protection plug- Catalogue Number ComProtect Overvoltage Protection 45

50 Flex MDF-Block Next Generation MDF Block with Maintenance-Free Overvoltage Protection The Next Generation MDF block mounts on the equipment side and is suitable for compact DSL distribution. The rear supports cable termination; the front supports jumpering and incorporates jumper management. Custom frame mounting is available for the block and can expand to fit any unused MDF space. Comprotect Overvoltage Protection Features The installed maintenance-free protection circuit needs no service and is particularly suited to collocation or remote office installations Low protection level and quick response time satisfy the requirements of today s exchange systems Three-electrode overvoltage arrestors assure high current discharge capability Reversible fuses satisfy the recommendations of ITU-T K20 and are maintenance-free even in the case of longterm disturbances Due to low-line capacitance, the blocks can be used in systems with high transmission rates. Flex MDF-Block Description Catalogue Number Flexible MDF blocks 96-pair disconnection block with maintenance-free protection pair disconnection block with maintenance-free protection

51 Mini-distributors ComGuard Maintenance-Free Overvoltage Protection System for Demarcation Points ADC KRONE offers system-independent, maintenance-free protection components for two-pairs in a small housing, suitable for installation at the demarcation point from the network operator to a home s cabling system. This small system is used primarily in analogue, ISDN and ADSL telecommunication systems for the protection of telecommunication facilities and terminal equipment such as FAX, modems, answering machines and computers. The protection circuit for each pair consists of a 3-pole overvoltage arrestor, reversible overcurrent protection components, as well as diodes for secondary overvoltage protection. When choosing protection, operating voltage and current must not exceed the values noted for the components. The overcurrent protection functions as a reversible line fuse. Installation requires neither special tools nor technical expertise. The earth connection is made using a screw connection. ComGuard maintenance-free protection Features System-independent two pair protection solution Wall mounted, compact unit installs easily by means of the LSA-PLUS tool Optimised service life-time ComGuard maintenance-free protection with RJ45 interface Designed for use in high transmission rate networks, the leading edge component technology guarantees protection of valuable systems Protection systems with RJ45 sockets support direct installation of terminal equipment One-pair version available for protection of analogue devices and PBX systems Description Maintenance-free protection system for demarcation points Weight/pack: kg Includes one LSA-PLUS simple insertion tool Dimensions (H x W x D) 31 x 75 x 54 mm Catalogue Number 2-pair OD180A5, connects 2 pairs, maximum operating voltage: 180V pair OD120A5, connects 2 pairs, maximum operating voltage: 120V Maintenance-free protection system with RJ45 sockets Weight/pack: kg; Maximum operating voltage: 180V Includes one LSA-PLUS simple insertion tool ComProtect Overvoltage Protection Specifications Material: Polyester Colour: RAL 9001 (cream-white) Protection class: IP 30 47

52 Mini-distributors ComGuard Mini-distributor for ComProtect Protection Plugs This ComGuard mini-distributor is equipped with an LSA-PLUS disconnection module (2/10) and a preconfigured earth connection, for the accommodation of 2/10 or ComProtect protection magazines. The disconnection module is mounted so that it can be turned 90-degrees. An earth line must be connected to the predefined connection point. Protection components are ordered separately. Comprotect Overvoltage Protection Features Replaceable protection components Simple to install Description ComGuard mini-distributor for ComProtect protection plugs for 1-pair protection plugs or 10-pair magazines Weight/pack: kg Mini-distributor with overvoltage and overcurrent for 2-pairs Weight/pack: kg Mini-distributor with overvoltage and overcurrent for 6-pairs Weight/pack: kg Specifications Material: Polyester ComGuard mini-distributor for ComProtect Protection Plugs Dimensions (H x W x D) Catalogue Number 170 x 120 x 35 mm x 65 x 35 mm x 65 x 35 mm Colour: RAL 7035 (light grey) Protection class: IP 30 48

53 Test Device for Protection Components Test Device The portable ComProtect test device allows measurement of tolerance limits, interruptions and short circuits in protection circuits, as well as automatic measurement of all positions of the corresponding adapter. Features Supports lifetime testing of 1-pair protection plugs and of magazines Battery-operated for mobile use Features exchangeable adapters Optional software module allows measurement data collection and statistical evaluation Enables individual programming of measurement limit values Provides automatic measurement Offers optical and acoustical fault recognition Description Weight/Pack Catalogue Number ComProtect test device 5.00 kg LSA-PLUS 2/10 adapter insert, with receptacle for LSA-PLUS magazine 2/10 and 1-pair ComProtect protection plug 10-pair LSA-PLUS NT adapter insert, with receptacle for 10-pair LSA-PLUS NT magazines and 1-pair ComProtect NT protection plug 8-pair LSA-PLUS NT adapter insert, with receptacle for 8-pair LSA-PLUS NT magazines and 1-pair ComProtect NT protection plug HighBand10 adapter insert, with receptacle for 10-pair HighBand magazines and 1-pair HighBand protection plug 5-pair MDF 71 adapter insert, with receptacle for 5-pair MDF magazines and 1-pair MDF 71 protection plug Software for ComProtect test device Software and adapter cable for data collection and statistical evaluation The ComProtect test device is delivered in a carrying case. Adapters and software to be ordered separately kg kg kg kg kg kg ComProtect Overvoltage Protection 49

PROTECTION SYSTEMS. 1st Edition

PROTECTION SYSTEMS. 1st Edition PROTECTION SYSTEMS 1st Edition Table of Contents Technical Reference Overview Protection systems in the communications network... 4 Applications of overvoltage protection... 4 Different forms of overvoltage...

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 1 st Edition LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially superior quick

More information

Systems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.

Systems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data. PSTN Protection The demand for voice and data communications has never been greater. Today, virtually everyone in the developed world has access to a land-line telephone, which carries their voice or data

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge arresters, type

More information

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing

3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing 3M ID 3000 System ID 3128 block Disconnection module ID 3100 block Wire guide housing 71 Disconnection element 72 The ID 3000 connection system is the latest generation of insulation displacement connector

More information

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany Lightning and Surge Protection of Photovoltaic Installations 1 Lightning and Surge Protection for PV Installations 2 Safeguard from Risks Ups, that was the insurance policy of my house!! 3 Why Lightning

More information

EMOSAFE EN-100 Network Isolators for PCB assembly

EMOSAFE EN-100 Network Isolators for PCB assembly ENGLISH EMOSAFE EN-100 Network Isolators for PCB assembly Product Datasheet 1 FEATURES AND ADVANTAGES Suitable for PCB assembly: pluggable or solderable Ultra-compact Conforms to IEC 60601-1 10/100/1000

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2014 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 combination surge arresters, type 1 / type

More information

BLITZDUCTOR XTU Universal lightning current / surge arrester

BLITZDUCTOR XTU Universal lightning current / surge arrester Pluggable DIN Rail Mounted SPDs Combined lightning current and surge arrester Max. discharge capacity for balanced data interfaces Capable of carrying lightning currents up to 10 ka (10/50 μs) For installation

More information

Surge & Filter Protection Addressing your industrial power quality needs.

Surge & Filter Protection Addressing your industrial power quality needs. Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin

More information

High Performance Network Isolator

High Performance Network Isolator EMOSAFE EN-1005 + High Performance Network Isolator Product Datasheet 1 FEATURES AND ADVANTAGES High performance Gigabit Ethernet 5.0 kv AC dielectric strength 8.5 kv DC dielectric strength Conforms to

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 201 /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 + type 2 /7 5SD7 combination surge arresters, type 1 / type 2 /9 5SD7 surge arresters, type

More information

Surge Protection for Surveillance Systems

Surge Protection for Surveillance Systems Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2013 Overvoltage Protection Devices /2 Introduction /3 5SD7 lightning arresters, type 1 /5 5SD7 combination surge arresters, type 1 and type 2 /7 5SD7 surge arresters, type 2 /10 5SD7 surge

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications TCMOV Varistors for Type 1 and Type What is UL 1449? Underwriters Laboratories standard UL 1449 has become the primary safety standard for surge protective devices (SPDs). It describes the materials and

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Making the Right Choices In Lightning & Surge Arrestors Some Basics:

Making the Right Choices In Lightning & Surge Arrestors Some Basics: Making the Right Choices In Lightning & Surge Arrestors Some Basics: It is a fact that the Highveld region of South Africa and Lesotho have amongst the highest lightning strikes per square km per annum

More information

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module

More information

Deploying surge protective devices (SPDs) in photovoltaic systems. Technical Information

Deploying surge protective devices (SPDs) in photovoltaic systems. Technical Information Deploying surge protective devices (SPDs) in photovoltaic systems Technical Information 2 00/09.08 Preface Preface Damages caused by overvoltage s are not only responsible for expensive repair costs; they

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.

Reliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes. Reliability in Surge Protection Surge Protection AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes www.citel.us CITEL Established in 1937, CITEL is the global leader in the development and

More information

ELPROMA NTSprotect Surge Protection

ELPROMA NTSprotect Surge Protection ELPROMA NTSprotect Surge Protection Rack 19 back panel with NTS-protect As the antenna is roof mounted (to have a clear view of the sky) it is likely to be exposed to lightning strikes. Protection against

More information

Type Code No. Weight Packaging [g] [pcs]

Type Code No. Weight Packaging [g] [pcs] Surge arresters surge arresters are intended for protection of electrical installations and devices against overvoltage effects, which may occur in atmospheric discharges and switching overvoltages. The

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks The Network of Networks 3M High Density Cross-Connect Modules STG2000 Series The 3M High Density Cross-Connect Modules STG2000 Series are IDC copper cross-connects that can be used in a wide variety of

More information

INFORMATION TECHNOLOGY SYSTEMS

INFORMATION TECHNOLOGY SYSTEMS Surge protection for INFORMATION TECHNOLOGY SYSTEMS SPDs for installations and equipment 131 Cross-reference Discontinued Products Alternatives Part No. Type Part No. Type Pluggable SPDs for DIN rail mounting

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Voice Integration Overview

Voice Integration Overview Voice Integration Overview 010.2936 Intelligent voice integration Highest packing density Modular design Efficient and tool-free connection technique Comprehensive product range Ingenious labelling system

More information

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections

Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation. Building Connections Surge protection for closed-circuit television systems (CCTV) Guide for support in planning and installation Building Connections Application Camera systems are used to monitor rooms, buildings and outdoor

More information

2 Principle of lightning protection

2 Principle of lightning protection 2 Principle of lightning protection The system for protecting a building against the effects of lightning must include: bprotection of structures against direct lightning strokes; bprotection of electrical

More information

DC562, digital input/output module,

DC562, digital input/output module, Ordering Data DATA SHEET DC562 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 231 900 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE

More information

Installation Instructions

Installation Instructions Installation Instructions (Catalog Number 1771-OD) This document provides information on: Because of the variety of uses for the products described in this publication, those responsible for the application

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

SPM Series. Plug-in Surge Protection

SPM Series. Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

for the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages

for the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages GAS-INSULATED METAL-ENCLOSED SURGE ARRESTERS (GIS-ARRESTERS) for the protection of gas-insulated metal-enclosed switchgear against lightning and switching overvoltages GIS-Arresters from Siemens GIS arresters

More information

3 Design of the electrical installation protection system

3 Design of the electrical installation protection system J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design

More information

DX561 Digital Input/Output Module

DX561 Digital Input/Output Module Ordering Data DATA SHEET DX561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2301 1TNE 968 901 R3101 DX561, digital input/output module, 8 DI

More information

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals

More information

Ethernet Protection A Whole Solution Han Zou, ProTek Devices

Ethernet Protection A Whole Solution Han Zou, ProTek Devices Ethernet Protection ------ A Whole Solution Han Zou, ProTek Devices Introduction: As Ethernet applications progress from 10BaseT to 10Gigabit and beyond, IC components are becoming more complicated with

More information

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.: Extract from the online catalog TT-ST-M-2-PE-24DC Order No.: 2858904 TERMITRAB, spring-cage modular terminal block with integrated surge protection and disconnect knives, for assembly on NS 35/7.5, voltage

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

DC561, digital input/output module,

DC561, digital input/output module, Ordering Data DATA SHEET DC561 Digital Input/Output Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2001 DC561, digital input/output module, 16 configurable inputs/outputs,

More information

Hazardous Area Protection

Hazardous Area Protection Hazardous Area Protection Global Solutions in Hazardous Area Surge and Lightning Protection Intrinsic Safety When instrumentation is installed in a potentially explosive environment steps must be taken

More information

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8

More information

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS G1 Outdoor Surge Protector for AC/Traction network VP range Dimensions (in mm) 19 M8 44 73 diam. 47 6 mm² Electrical

More information

Technical Specification

Technical Specification EMC TESTS, SEMINARS, HARD AND SOFTWARE Technical Specification No. E-MIG1206-3P.doc Revised: 10.March 2007 1 MIG Tester Type MIG1206-3P 1 MIG Tester Type MIG1206-3P 1 1.1 Introduction 1 2 General 2 2.1

More information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information Signal conditioning instruments for level switches Conductive VEGATOR C VEGATOR VEGATOR Product Information Content Content Product description..........................................................................

More information

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management. RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels 20 Channel Branch Circuit Monitoring Device with RCM Interfaces / communication RS485 RTU Accuracy of measurement

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

the data line series

the data line series the data line series 12-00131 OUTDOOR SINGLE PORT POE RJ45 SURGE ARRESTOR rev0-10/100/1000 Base-T CAT5e Protection - IEEE 802.3 A/F Power Mode B - Solid-state silicon-avalanche diodes with internal TVS

More information

TU531, TU532 Terminal Unit

TU531, TU532 Terminal Unit Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,

More information

FS Series PV Modules Reverse Current Overload

FS Series PV Modules Reverse Current Overload FS Series PV Modules Reverse Current Overload Purpose The purpose of this document is: to describe the system conditions that can cause reverse current overload (RCOL) and the behavior of FS modules in

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

PCT2000. User Manual. Precision current transducer 2000 A

PCT2000. User Manual. Precision current transducer 2000 A PCT2000 User Manual PCT2000 Precision current transducer 2000 A User Manual Status: November 6, 2018 Copyright 2018 ZES ZIMMER Electronic Systems GmbH Pfeiffstraße 12 61440 Oberursel (Taunus), Germany

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR RJ CONNECTION. DEHNlink Surge arrester SPD X 2 No. 929 02 Line 7, V 2, ka Surge arrester Surface-mountable surge protective device for telecommunication systems Quick installation due to plug-in terminals Different types specified for interfaces

More information

Surge Protection Devices Ex9UE2

Surge Protection Devices Ex9UE2 Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,

More information

Multifunctional time delay relay MFT U31S, MFT U41SE

Multifunctional time delay relay MFT U31S, MFT U41SE 8 Functions, 8 time ranges Multivoltage: 24 Vac / dc 110... 240 Vac 2 output contacts MFT U31S Functions E Delay on E Delay on - version with control contact as opening contact A Delay off without auxiliary

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

ITU-T K.118. Requirements for lightning protection of fibre to the distribution point equipment SERIES K: PROTECTION AGAINST INTERFERENCE

ITU-T K.118. Requirements for lightning protection of fibre to the distribution point equipment SERIES K: PROTECTION AGAINST INTERFERENCE I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T K.118 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (12/2016) SERIES K: PROTECTION AGAINST INTERFERENCE Requirements for lightning

More information

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation SOCKET OUTLET (RJ5) Surge Arrester LAN fine protection for fixed installation Protection for all lines Shielded socket outlet, Category 5 Data socket outlet (Category 5) with integrated surge protection.

More information

DI561 Digital Input Module

DI561 Digital Input Module Ordering Data DATA SHEET DI561 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1TNE 968 902 R2101 1TNE 968 901 R3101 1TNE 968 901 R3103 1TNE 968 901 R3105 DI561, digital

More information

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment NTSA has developed the ultimate solution for protecting

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1D V21.212 Version 1.1 Note: the picture on the frontpage is a meter from the series of this meter, it might not be exactly the same

More information

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - on base plate Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester These modular distribution panel protectors for three phase power systems are designed to prevent damage to electrical distribution systems from mainsborne transient voltages which can occur as the result

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

Gas Discharge Tubes GTCX36-XXXM-R10 Series

Gas Discharge Tubes GTCX36-XXXM-R10 Series GTCX36-XXXM-R10 Series TE Circuit Protection 6mm 3Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Contact protection relay

Contact protection relay Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection OVR Range FRSOX 0100 03 GB ABB Lightning Protection Group 1 Main causes of transient overvoltages The solution: ABB OVR Surge Protective Device Range Lightning strike A lightning

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

DI572 Digital Input Module

DI572 Digital Input Module Ordering Data DATA SHEET DI572 Digital Input Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 230 500 R0000 1TNE 968 901 R3101 1TNE 968 901 R3102 1TNE 968 901 R3103 1TNE 968

More information

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O DATASHEET NI REM-11178 Digital Output Module for Remote I/O Short circuit and overload protection Drives up to 500 ma per channel (up to 8A per module) Spring-terminal connectors allow fast wiring without

More information

MINI MCR-SL-PT100-UI(-SP)(-NC)

MINI MCR-SL-PT100-UI(-SP)(-NC) Configurable Temperature Transducer for PT100 Data Sheet 04/2005 Functions MINI MCR-SL-PT100-UI(-SP)(-NC) is a configurable 3-way isolated temperature measuring transducer. It is suitable for the connection

More information

High impedance protection relay

High impedance protection relay High impedance protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features High impedance type differential current earth-fault protection, so called restricted

More information

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs 10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs IEEE802.3 10 Mb/s Single Twisted Pair Ethernet Study Group 9/8/2016 1 Overview Introduction Current bus Infrastructure

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment

Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment Technical Requirements for High-voltage DC Power Feeding Interfaces of ICT equipment TR No. 176002 1.1.EDITION April 1st, 2015 Nippon Telegraph and Telephone Corporation Introduction This document describes

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

Technical Specification for High Density UniSplit ADSL Central Office and Remote Cabinet Splitter

Technical Specification for High Density UniSplit ADSL Central Office and Remote Cabinet Splitter Version 1.0-08/2008 Telecom Outside Plant Technical Specification for High Density UniSplit ADSL Central Office and Remote Cabinet Splitter 1. DESCRIPTION 2. TECHNICAL REFERENCES 3. WIRING SCHEMATIC SP-USL.HD-vr1.1

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Technical Data Sheet Medium Current Power Surge Filters

Technical Data Sheet Medium Current Power Surge Filters Technologies Technical Data Sheet Medium Current Power Surge Filters Features High performance surge protector for an operating voltage of 0-220Vac Designed to withstand fault and over-voltage conditions

More information

Residual overvoltage relay

Residual overvoltage relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Definite-time residual overvoltage earthfault protection and supervision Two independent operation stages, e.g. one

More information