ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs

Size: px
Start display at page:

Download "ABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs"

Transcription

1 COMMANDER 00 Circular Chart Recorder Specification DataFile to pens full application flexibility NEMA X/IP construction hose-down protection Analog, relay outputs, digital inputs and transmitter power supply as standard range of inputs and outputs built in Multiple -digit indicator panels continuous display of all signal values 0.% measurement accuracy precise process information High noise immunity robust, dependable operation RS MODBUS serial communications open systems compatibility Totalizers and math functions built-in fully integrated solutions COMMANDER 00 a rugged, reliable recorder with the full capability to meet your application needs ABB Instrumentation

2 COMMANDER 00 The COMMANDER 00 is a fully programmable circular chart recorder for up to four process signals. The COMMANDER s straightforward operator controls and robust construction make it suitable for a variety of industrial environments. Excellent standard facilities are complemented by a powerful range of options to give the flexibility to match your application. Simple Operation Comprehensive Process Information The COMMANDER lets you see the status of your process at a glance: high visibility -digit displays provide a clear indication of up to four process values simultaneously and active alarms are signalled by flashing LED s below the main display. The clearly-labelled tactile keypad gives direct access for operator adjustments and configuration programming, without the need to open the recorder s door. Clear text prompts on the digital displays guide the user around the various menus. A password-protected security system prevents unauthorized access to configuration adjustment menus. The chart is easily set up to show the information you need in the way you want. Pen ranges are individually set to give the best resolution for each signal; the time per revolution can be selected between hour and days. Additionally a true time event pen facility enables one pen to be set up as a -position event marker on the same time line as Pen. P.M. 0 P.M. P.M. MID NIGHT A.M. 0 P.M

3 Flexibility to Solve Problems The COMMANDER 00 offers seamless integration of loop functionality to solve process problems, eliminating the need for auxiliary devices. Totalizers, Math and Logic Integrating fluid flow to calculate total volume is performed by the built-in totalizers available for each channel. Relays can be assigned to increment or reset external counters to match the recorder s totalizer values. User configurable math functions, mass flow calculations and RH tables are all fully supported. Logic capability allows interlocking and integration of discrete and continuous functions to solve a wide range of process problems. COMMANDER 00 Flow A Flow B Flow C A B C Math Equation Totalizer 0. Timers and Clock The COMMANDER offers two event timers driven by the recorder s real-time clock. The timers can be configured to operate relays, start/stop the chart or trigger other actions within the recorder. Summation of Three Flows MODBUS RS Communications Timer Annunciator 0 Channel alarm Logic Equation AND Relay Communications with PCs or PLCs are achieved via the RS serial communications link, enabling the COMMANDER to serve as the front end of plant-wide data acquisition systems. Using MODBUS RTU protocol all process inputs and other variables can be continuously read by a host PC running any of a wide variety of standard SCADA packages. Alarm annunciation enabled during night hours only.

4 Built to Meet Your Needs The COMMANDER s modular architecture gives rise to a high level of hardware choice: up to five i/o modules can be added to the basic instrument. The standard input/output module supplied with every pen comes complete with a fully isolated analog input, a relay output, transmitter power supply, isolated analog retransmission and two digital inputs. Further input and output capability is provided by a range of plug-in modules: Analog input and relay for use with math functions Four relays channel alarm outputs Eight digital inputs linked using logic equations Eight digital outputs TTL level alarm outputs MODBUS RS communications interfaces with P.C.s Expandable for the Future The COMMANDER may be quickly upgraded to meet your changing process requirements. Additional recording channels, math capability or input and output functions can be retrofitted on-site using plug-in cards and easily fitted pen arms. Input calibration data is stored on each card, allowing quick changes to input cards without the need for recalibration. Changes to input sensors or recording procedures are accommodated by reconfiguration using the main keypad. Designed to Survive NEMA X protection ensures the COMMANDER can survive in the harshest environments and makes the recorder ideal for use in panels which are regularly hosed down. The tough, acidresistant case and secure cable-entry glands maintain the NEMA X rating for wall-mounted or pipe-mounted instruments. Noise Immunity Recording accuracy is maintained in noisy industrial environments due to the advanced EMC shielding within the recorder. The power supply has been designed to give excellent protection from power spikes and brownouts and all configuration and status information is held in nonvolatile memory to ensure rapid recovery after a power failure. Easy to Install A choice of mounting options enables simple installation of the recorder in a panel, on a wall or on a pipe. Detachable terminal blocks allow for trouble-free connection of input and output wiring, with mains isolation provided by a power switch within the instrument. Minimal Maintenance Excellent long-term stability keeps recalibration to a minimum, cutting the costs of ownership. User-selectable chart speeds and long-life pens combine to limit usage of consumables. Built-in Quality The COMMANDER 00 is designed, manufactured and tested to the highest quality standards, including ISO 00, and is guaranteed by a year parts and labour warranty.

5 Summary,, or pens 0" Chart size Standard i/o with each pen includes: Analog input, analog output, transmitter power supply, relay output and digital inputs. General Specification Construction Size:." (h) x.0" (w) x." (d) (. x.0 x.mm) Weight: lb (.kg) Case material: Glassfiber-filled reinforced polyester Window Material: Polycarbonate Door latch: High-compression with optional lock Environmental Operational temperature range: to 0 F (0 to C) Operational humidity range: to %RH (non-condensing) to 0%RH (chart only) Case sealing: NEMA X (IP) Fast transients: IEC 0- Level Installation Mounting options: Panel, wall or pipe Terminal type: Screw Wire size (max): AWG (i/o), AWG (power) Operation and Configuration Programming method: Via front panel keys Security: Password protected menus Safety General safety: IEC Dielectric: 00V dc (channel/channel) kv dc (channel/ground) Memory protection: Nonvolatile EEPROM Approvals: CSA (optional) CE Power Supply Voltage: /0V ac ±%, 0/0Hz Consumption: < 0 VA (typical for full spec. unit)) Line interruption: Up to 0ms Process Inputs and Outputs General Noise Rejection: mode > 0dB at 0/ 0Hz Normal (series) mode > 0dB at 0/0Hz CJC rejection ratio: < 0.0 C/ C Sensor break protection: Upscale or downscale drive Out of range detection: 0 to 00% of engineering span Temperature stability: < 0.0% of reading/ C or µv/ C Long-term drift: < 0.0% of reading 0µV annually Input impedance: > 0 MΩ (mv and V inputs) 00 Ω (ma input) Analog Inputs Signal types: mv, V, ma, Ω Thermocouple types: B, E, J, K, N, R, S, T Resistance Thermometer: Pt 00 Other linearizations: x /, x /, x /, linear Sample interval: 0ms per channel Dielectric: 00Vdc channel/channel Digital Filter: 0 to 0s programmable -Wire Transmitter Power Supplies per channel Voltage: Vdc nominal Drive: Up to ma Isolation: 00Vdc channel/channel Type Type Lo Lo C F Hi Hi Lo Min. Span Hi Accuracy (excl. CJC) B ±. 0 C (above 00 C) E ± 0. C J ± 0. C K ± 0. C N ± 0. C R ±. 0 C (above 00 ) S ±. 0 C (above 00 C) T ± 0. C PT ± 0. C Accuracy mv 0 0 ± 0.% reading or 0µV V 0 0. ± 0.% reading or 0µV ma 0 0 ± 0.% reading or 0. µa Ohms (low) ± 0.% reading or 0. Ω Ohms (high) 0 0k 00 ± 0.% reading or 0Ω

6 Analog Outputs to 0 ma Accuracy: ±0.% Maximum load: 0 Ω Dielectric: 00V dc Relay Outputs SPDT Rating (with non-inductive load): A at /0Vac Digital Inputs TTL or volt-free Minimum pulse: 0ms Dielectric: 00Vdc between modules, no isolation within module Digital Outputs V TTL Rating: ma per output Dielectric: 00Vdc between modules, no isolation within module Serial Communications Connections: RS, wire Protocol: MODBUS RTU Pneumatic inputs/outputs to psig I/P, to psig P/I Mounting: External DIN rail on rear of unit Recording System Display and Operator Panels Displays Status indicators: Alarm indicators: Panel keys Function: Alarms and Logic ( or pens) or ( or pens) -digit red LED, 0. in. (mm) high Indicate channel number on display Indicate channel with active alarms Programming access, increment/ decrement, pen lift and user-defined function key. Alarms per channel High/low process, fast/slow rate of change Adjustments: Hysteresis, time delay Logic Equations Function: OR, AND Inputs: Alarm states, digital inputs, totalizers, logic Outputs: Relays, digital outputs, chart stop, alarm acknowledge Advanced Software Functions Pens Response: Resolution: Pen lift: Event Pens Standard: Real time: Chart Chart size: Chart speed:,,, or (red, blue, green, black) seconds (full scale) 0.% steps Motor-driven, with optional autodrop -position event recording on any channel -position event recording on the same time line as Pen 0 in. or 0mm to hours or to days per revolution Totalizers per pen Size:,, max. Output: External counter driver, wrap pulse signal Math Number of eqns.:,, x,, low & high select, max, min, average, mass flow, RH Timers Real-time clock driven event, adjustable duration Output: Relay, digital output, logic equation Option Connection: plus x standard input/output module Plug in cards with detachable connection blocks Option Types Analog i/p Analog o/ p Trans. PSU i/o per module Relays Digital i/ p D igital o/ p Comms. Max. No. per instrmt Standardi/o Analog i/p relay relays digital i/p digital o/p RS comms. 0J (non-upgradeable)

7 Ordering Guide PART COMMANDER 00 Recorder XX X X X X X X X X X X X XXX Recorders Chart Type Electrical Code Option Options Door Lock Power Supply Special Settings One Pen (Red) Two Pens (Red & Green) Three Pens (Red, Green, Blue) Four Pens (Red, Green, Blue, Black) Standard KPC 0 PX and PXR type charts Chessell Brand charts Standard CSA approval UL approval CSA/FM Class Div. None Additional s Complete PART None Totalizer Totalizer, Maths & Timer Not Fitted Fitted V A.C. 0V A.C. V A.C. V A.C. with On/Off Switch 0V A.C. with On/Off Switch V A.C. with On/Off Switch Company Standard Customer Setting Special J K C A B U F 0 A 0 B STD CUS SXX Each pen fitted has an associated standard Input/Output module output, Relay, Transmitter Power Supply and Two Digital Inputs. Additional Input/Output modules may be fitted in the unused Positions additional modules should be specified in PART of the Ordering Guide comprising Analog input, Analog as required. These PART Additional s Type Position / Channel Input* 0 Position / Channel Input* 0 Position / Channel Input * 0 Position 0 0 Position 0 Key to Types 0 No module fitted / Pen input channel * Standard Input/Output Analog Input (Math input) Relay Four Relays Eight Digital Inputs Eight Digital Outputs True Time Event Pen (Violet) MODBUS RS Communications * On, or pen instruments a standard I/O module is always fitted in the corresponding module position (enter 0 in the corresponding order code field). Positions Example J A A STD pen relays RS communications

8 X 0 Analog Output Tx Analog Input see b to h d -wire Transmitter Logic Logic Inputs Logic Normally Open Relay Output Position Position Position Position Position Position Power Switch and Fuse Summary of Connections e Thermocouple g Low Voltage (mv) b Voltage c Current (non -wire Transmitters) Red White Red f -wire RTD Standard Input/Output s Link White Red h -wire RTD and Resistance Line Neutral Ground Power Supply Connections 0 Normally Open Relay Normally Open Relay Normally Open Relay Normally Open Relay Four Relay Output 0 Input Input Input Input Input Input Input Input Input Connections or Digital Input/Output Output Output Output Output Output Output Output Output Output Connections holes 0. dia. or tap for /" thread. Cut-Out Size Typical Space Between Adjacent Knockout Centers.. 0. Dimensional Details The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB (.) SS/C00R Issue ABB Instrumentation Ltd Howard Road St. Neots, Cambs. England, PE EU Tel: (0)0-- Fax: (0)0-- ABB Automation Inc Instrumentation Division E. County Line Road Warminster, PA USA Tel: Fax: -- ABB Instrumentation 0 Lenno Como Italy Tel: (0)- Fax: (0)-

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs

C1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs Data sheet DS/C900R EN Rev. U C900 Series C900 a rugged, reliable recorder with the full capability to meet your needs to pen recording full application flexibility NEMA X/IP construction hose-down protection

More information

Inform IT Circular Chart Recorder/ Controller

Inform IT Circular Chart Recorder/ Controller Data Sheet Inform IT Circular Chart Recorder/ Controller to pen recording full application flexibility or controllers integrated control and recording Analog, relay outputs, digital inputs and transmitter

More information

Inform IT Single Pen Circular Chart Recorder

Inform IT Single Pen Circular Chart Recorder Data Sheet SS/_ Inform IT Single Pen Circular Chart Recorder Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers included as standard -digit indicator

More information

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument Data sheet DS/C100 EN Rev. H C100 C100 dependable recording in a rugged, functional instrument High-definition backlit display latest LCD panel display technology ensures instrument operation and configuration

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder ABB MEASUREMENT & ANALYTICS DATA SHEET C100 Advanced circular chart recorder C100 ADVAN CED CI RCUL AR CHART RE CORDE R DS/C 1 00/U S-E N RE V. L Measurement made easy C100 dependable recording in a rugged,

More information

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument

C1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument Data sheet DS/C1300 EN US Rev. J C1300 C1300 dependable recording in a rugged, functional instrument High-definition backlit display latest LCD panel display technology ensures instrument operation and

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

Wall-/Pipe Mounted Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement

More information

C160 Wall-/Pipe Mounted Universal Process Indicator

C160 Wall-/Pipe Mounted Universal Process Indicator Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement

More information

/8 DIN Motorized Valve Controller

/8 DIN Motorized Valve Controller Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation

More information

100mm Process Indicator Recorder

100mm Process Indicator Recorder Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing

More information

Recorders for all applications

Recorders for all applications Recorders for all applications Within the COMMANDER family are specifically-designed control solution variants for industries such as water and waste water, food, chemical & pharmaceutical and heat treatment.

More information

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications Data Sheet SS/C50_7 Control IT /6 DIN Controller/Alarm Unit C50 High visibility dual 4-digit display shows set point and process variable Standard relay or logic control output simple time proportioning

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

Universal Process Controller

Universal Process Controller Data Sheet SS/_9 Universal Process ontroller Single output, Heat/ool or Motorized Valve control one controller for every PID control application 9 program, segment Ramp/Soak comprehensive set point profiling

More information

Commander circular chart recorders The tried and tested solution for process recording

Commander circular chart recorders The tried and tested solution for process recording The tried and tested solution for process recording ABB s Commander circular chart recorders provide a tried and tested solution for a host of industries such as water and waste water, food, chemical and

More information

C /4 DIN Multi-Recipe Profile Controller. C360 a comprehensive profile controller for all ramp/ soak applications

C /4 DIN Multi-Recipe Profile Controller. C360 a comprehensive profile controller for all ramp/ soak applications Data sheet DS/EN Rev. E a comprehensive profile controller for all ramp/ soak applications Dedicated for ramp/soak profile applications easy to use and follow customized display with direct control of

More information

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller

ABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller Specifications COMMANDER 505 Advanced Process Controller Multiple PID control capabilities single loop, feedforward, cascade, feedforward with cascade, ratio, auto/manual station, analog backup, heat/cool

More information

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input

More information

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy

ControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy Data sheet DS/CM15 EN Rev. E ControlMaster CM15 Universal process indicator, 1 /8 DIN Making process control easy Comprehensive display of process status Crystal-clear, full-color TFT display User-customizable

More information

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output

More information

ABB Instrumentation. Multipoint Chart Recorder COMMANDER SR250B. Specification DataFile

ABB Instrumentation. Multipoint Chart Recorder COMMANDER SR250B. Specification DataFile OMMANDER SR0B Multipoint hart Recorder Specification DataFile OMMANDER SR0B Simplicity and ease of use in a rugged, compact 0mm recorder -channel recording on 0mm chart with individual trace colors High

More information

ControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy

ControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy Data sheet DS/CM10 EN Rev. K ControlMaster CM10 Universal process controller, 1 /8 DIN Making process control easy Comprehensive display of process status Crystal-clear, full-color TFT display User-customizable

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

MRC 7000 Proven Recording Reliability that Became the Industry Standard! Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables

More information

ControlMaster CMF160 Universal process indicator, fieldmount

ControlMaster CMF160 Universal process indicator, fieldmount Data sheet DS/CMF160 EN Rev. C ControlMaster CMF160 Universal process indicator, fieldmount Making process indication easy Measurement made easy Cost saving field-mount design Wall-, pipe- or panel-mountable

More information

PXR Series Advanced Self-Tuning Temperature and Process Controllers

PXR Series Advanced Self-Tuning Temperature and Process Controllers PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater

More information

MODCELL 2050R Single Loop Controllers

MODCELL 2050R Single Loop Controllers Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile

More information

Inform IT 250mm Multipoint Strip Chart Recorder

Inform IT 250mm Multipoint Strip Chart Recorder Data Sheet SS/_ Inform IT 0mm Multipoint Strip hart Recorder -channel recording on 0mm chart with individual trace colors Universal process inputs accepts thermocouples, RTDs, ma, mv & V lear text annotation

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Strip Chart Recorders Specification Sheet

Strip Chart Recorders Specification Sheet 4101C, 4101M 4102C, 4102M MODELS Continuous Pen Recording 1, 2, 3 or 4 Pens Multi-point Recording Providing 6 Colour traces High Visibility Display 4101C, 4101M Clear Analogue Scale 4102C, 4102M Large

More information

Control IT Booster Pump Controller

Control IT Booster Pump Controller Data Sheet SS/_4 Control IT Booster Pump Controller Protection for the pasteurization process ensuring a high quality, safe product for your customers High visibility LED displays continuous indication

More information

Pasteurizer Recorder and Recorder Controller

Pasteurizer Recorder and Recorder Controller Data Sheet SS/C1950 Issue 9 Pasteurizer Recorder and Recorder Controller C1950 (STLR & HTST) Dedicated Pasteurizer Recorder/Controller designed to meet requirements of the pasteurization processes High

More information

LBVR1718. Description. Features channel paperless recorder

LBVR1718. Description. Features channel paperless recorder LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,

More information

SX90 Process Controller

SX90 Process Controller Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector. PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION

More information

250mm Advanced Process Recorder

250mm Advanced Process Recorder Data Sheet SS/_4 0mm Advanced Process Recorder 4-channel recording on 0mm chart with individual trace colors Universal process inputs accepts thermocouples, RTDs, ma, mv & V Totalizers, math and logic

More information

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet

DATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet OVERVIEW The DATAWATCH IX monitor offers an excellent graphical display and recording device for a box of its size. The compact panel mount unit offers four isolated or eight non-isolated high accuracy

More information

DUAL-LINE TEMPERATURE METER

DUAL-LINE TEMPERATURE METER DUAL-LINE TEMPERATURE METER PROPLUS YPP7000 J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors Automatic Cold

More information

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart PARTS LIST N PL/C19_C13 Issue 4 Product C1900 and C1300 Circular Chart Recorders Manual N/A Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart Overview This parts list contains: exploded

More information

dual-line 6-dIGIt process MeteR

dual-line 6-dIGIt process MeteR dual-line 6-dIGIt process MeteR ProVu Se r i e S provu Model pd6000 0-20 ma, 4-20 ma, 0-5 V, 1-5 V, and ±10 V Inputs NEMA 4X, IP65 Front Universal 85-265 VAC or 12/24 VDC Input Power Large Dual-Line 6-Digit

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter. H3 Series Dual-Line 6-Digit Temperature Meter Temperature J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors

More information

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart

Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart PARTS LIST N PL/C19/C13 Rev. I Product C1900 and C1300 Circular Chart Recorders Manual N/A Replacement Parts and Upgrade Kits for C1900 and C1300 Circular Chart Overview This parts list contains: exploded

More information

ABB Instrumentation. Advanced Process Controller COMMANDER 505. Specification DataFile

ABB Instrumentation. Advanced Process Controller COMMANDER 505. Specification DataFile COMMANDER 505 Advanced Process Controller Specification DataFile Multiple control capabilities single loop, feedforward, cascade, feedforward with cascade, ratio, auto/manual station, analog backup, heat/cool

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. ControlMaster CM10 Universal process controller, 1/8 DIN

ABB MEASUREMENT & ANALYTICS DATA SHEET. ControlMaster CM10 Universal process controller, 1/8 DIN ABB MEASUREMENT & ANALYTICS DATA SHEET ControlMaster CM10 Universal process controller, 1/8 DIN 2 CO N TRO LMASTE R CM10 UN I VERSAL PROC E SS CONTROLLE R 1/8 DIN DS/C M10-E N RE V. P Measurement made

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

The CAL range of temperature controllers

The CAL range of temperature controllers The CAL range of temperature controllers CAL Temperature Controllers Auto-tuning P.I.D. Controllers with RS232/485 Communication, Charting and Logging Software The CAL range of temperature controllers

More information

DPR 100 A/B Analog Scales

DPR 100 A/B Analog Scales DPR 100 A/B Analog Scales 0I-6030 8/95 Pen and Multipoint 100 mm Digital Recorders Specification and Technical Data Introduction The DPR 100 is a microprocessor based 100 mm (4 inch) strip chart recorder

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

HIGH-VOLTAGE DC METER

HIGH-VOLTAGE DC METER HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

ABB Instrumentation. Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP

ABB Instrumentation. Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP COMMANDER 900 Series Circular Chart Recorders Installation Guide All Versions COMMANDER 900 00. 98. OP. 00.!0.8 degf ABB Instrumentation ABB INSTRUMENTATION The Company ABB Instrumentation is an established

More information

Basic Temperature and Limit Controllers

Basic Temperature and Limit Controllers Basic Temperature and Limit Controllers Basic Temperature and Limit Controller Provide Economical Solution for a Wide Range of Applications The basic and limit microprocessor-based controllers from Watlow

More information

Field Mountable Videographic Recorder

Field Mountable Videographic Recorder Data Sheet 160002 Issue 2 Field Mountable Videographic Recorder A305! Unique universal mounting capability wall-, pipe- or panel-mount ultra-slim design, 90mm (3.5 in.) deep! Secure data recording large

More information

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation

More information

Temperature/Process Controllers Manual

Temperature/Process Controllers Manual 3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features

More information

Power Meter PowerMonitor 500

Power Meter PowerMonitor 500 ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific

More information

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0. LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate

More information

PD Helios Dual-Line 6-Digit Temperature Meter. Actual Size Digit

PD Helios Dual-Line 6-Digit Temperature Meter.   Actual Size Digit PD2-7000 Helios Dual-Line 6-Digit Temperature Meter Actual Size Digit Temperature Large 1.80" Digits Dual-Line 6-Digit Display Readable from up to 100 Feet (30 Meters) Away Superluminous Sunlight Readable

More information

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES D1000 FEATURES Complete sensor to RS-232/RS-485 interface. 500V rms analog input isolation. 15 bit measurement resolution. Continuous self-calibration;

More information

/2 DIN Advanced Process Controller

/2 DIN Advanced Process Controller Data Sheet Control IT Multiple control capabilities single loop, feedforward, cascade, feedforward with cascade, ratio, auto/manual station, analog backup, heat/cool Clear process display and color-coordinated

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET SPECIFICATION SHEET Basic Temperature and Limit Controllers Basic Temperature and Limit Controllers Provide Economical Solution for a Wide Range of Applications The basic and limit microprocessor-based

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES. PD7000 PROVU Dual-Line 6-Digit Temperature Meter PR VU SERIES Temperature J, K, T, E, R, S, B, N, C Thermocouples 00 or 000 Ω Platinum, 0 Ω Copper, 0 Ω Nickel RTDs or 0. Resolution Averages up to 0 RTD

More information

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type

More information

C1950 (STLR & HTST) Pasteurizer Recorder and Recorder Controller

C1950 (STLR & HTST) Pasteurizer Recorder and Recorder Controller Data sheet DS/C1950 EN Rev. K C1950 (STLR & HTST) The complete recording and control solution for pasteurization processes Dedicated Pasteurizer Recorder/Controller designed to meet requirements of the

More information

InteliLite MRS17 Click Here to Learn More

InteliLite MRS17 Click Here to Learn More InteliLite MRS17 Click Here to Learn More Comprehensive Genset Controller Brief Description The InteliLite is a cost effective controller for generator sets in stand-by and prime power applications. The

More information

ABB Instrumentation. Specification DataFile. COMMANDER 355 advanced single loop controller in a short case, 1 /4 DIN format

ABB Instrumentation. Specification DataFile. COMMANDER 355 advanced single loop controller in a short case, 1 /4 DIN format COMMANDER 355 Advanced Process Controller Specification DataFile controller with multiple control strategies single loop, feedforward, cascade, ratio, auto/manual station and analog backup controller Three

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System WHERE THE FUTURE MEETS THE PRESENT Datascan solo Network Based Data Acquisition System CONTENTS INTRODUCTION 1 ANALOG INPUT/OUTPUT MODULES &3 DIGITAL INPUT/OUTPUT MODULES PRODUCT FEATURES &5 NETWORK CONTROLLERS,

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

Indicators. Product Mounting Display Height Page

Indicators. Product Mounting Display Height Page Product Mounting Display Height Page EZ-ZONE PM 1 /32, 1 /16, 1 /8, 1 /4 DIN front panel Upper/Left: 0.30 to 0.80 in. (8 to 20 mm) Lower/Right: 0.22 to 0.50 in. (6 to 13 mm) 379 EZ-ZONE RUI and Gateway

More information

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty

Safety: UL508 EMC: CE IEC , IEC Vibration: IEC (2 g s during operation) Warranty NA-4020/4021 RS-485 or RS-232 network adaptors ioogik 4000 Modbus RS-485 NA-4020 SYS TxD RxD I/O Field Power CH0 24V 0V SG SG System Power (0 VDC) System Power (24 VDC) Shielding Ground Non-isolation Switching

More information

Digital Indicator Solutions

Digital Indicator Solutions Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display

More information

DIGITAL INDICATING CONTROLLER

DIGITAL INDICATING CONTROLLER DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various

More information

Field Mountable Videographic Recorder

Field Mountable Videographic Recorder Data Sheet SS/SM500F Issue 8 Field Mountable Videographic Recorder SM500F Unique universal mounting capability wall-, pipe- or panel-mount ultra-slim design, 90mm (3.5 in.) deep Secure data recording large

More information

HIT/HIX HART Isolator

HIT/HIX HART Isolator / Isolator December 2017 Description Moore Industries Isolators provide highly economical solutions to common and costly problems that plague many of today s smart process loops. Protect and enhance your

More information

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS The MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS Mighty-5 DPM MODELS Micro-P & Mighty-1 Mighty-1 Micro-P ELECTRO-NUMERICS, INC. Introduction The Electro-Numerics family of Digital Panel Meters and

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller

ABB MEASUREMENT & ANALYTICS DATA SHEET. C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller ABB MEASUREMENT & ANALYTICS DATA SHEET C1950 (STLR & HTST) Pasteurizer recorder and recorder / controller 2 C1950 (STLR & H TST ) PAST EURI ZE R RE CORDE R AND RE CORDE R / CONTROLLE R DS/C 1950-E N RE

More information

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017

NOW A PRODUCT! 1/4 DIN Auto/Manual Station. The Interface Solution Experts. The Interface Solution Experts. PS532 V6 March 2017 NOW A 5 3 2 The Interface Solution Experts PRODUCT! 5 3 2 1/4 DIN Auto/Manual Station The Interface Solution Experts PS532 V6 March 2017 GENERAL DESCRIPTION The 532 Auto/Manual Station ensures the integrity

More information

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES 11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet

More information

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.

More information

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise

West Instruments. The MLC compact multi-loop controller... MLC ends the control or integration compromise The MLC 9000+ compact multi-loop controller... MLC 9000+...ends the control or integration compromise Why the MLC 9000+? Use the MLC 9000+ as a discrete controller mounted behi either as a stand-alone

More information

Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP

Installation Guide. COMMANDER 1900 Series Circular Chart Recorders. All Versions !50.8 degf OP COMMANDER 900 Series Circular Chart Recorders Installation Guide All Versions COMMANDER 900 00. 98. OP. 00.!0.8 degf ABB AUTOMATION The Company ABB Automation is an established world force in the design

More information

Agency Approvals. Mounting DIN-rail UL, CSA, CE, RoHS, W.E.E.E., SEMI F UL, CSA, CE, RoHS, W.E.E.E., FM, SEMI F

Agency Approvals. Mounting DIN-rail UL, CSA, CE, RoHS, W.E.E.E., SEMI F UL, CSA, CE, RoHS, W.E.E.E., FM, SEMI F Product EZ-ZONE RM High-Density Limit EZ-ZONE RM High-Density Scanner EZ-ZONE PM Limit EZ-ZONE PM Express Limit Maximum Limit Loops Maximum Monitor Channels Mounting Agency Approvals 192 192 DIN-rail UL,

More information

LE ELECTRONICS Pvt. Ltd.

LE ELECTRONICS Pvt. Ltd. LE ELECTRONICS Pvt. Ltd. Monitoring Relays: LVM Line Voltage Monitors LCM - Line Current Monitors VMR Voltage Monitoring Relays CMR Current Monitoring Relays VCMR Voltage Current Monitoring Relays LFM

More information

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006 PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical

More information

PD765 TRIDENT. Trident Series Process & Temperature Meters.

PD765 TRIDENT. Trident Series Process & Temperature Meters. PD765 Trident Series Process & Temperature Meters TRIDENT PROCESS & Temp 4-20 ma, ± 10 V, TC & RTD Inputs 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) Type 4X, NEMA 4X, IP65 Front 1/8 DIN Shallow

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information