ABB Instrumentation. Multipoint Chart Recorder COMMANDER SR250B. Specification DataFile
|
|
- Ernest Camron Atkinson
- 5 years ago
- Views:
Transcription
1 OMMANDER SR0B Multipoint hart Recorder Specification DataFile OMMANDER SR0B Simplicity and ease of use in a rugged, compact 0mm recorder -channel recording on 0mm chart with individual trace colors High clarity graphics display shows process status at a glance Universal process inputs accepts thermocouples, RTDs, ma, mv & V Dust- and water-resistant to IP (NEMA) for harsh industrial environments lear text annotation on chart time, date, scales, speed, alarms and batch Modbus serial communications provide full integration with your control system ABB Instrumentation
2 OMMANDER SR0B The OMMANDER SR0B provides accurate and reliable recording of up to process signals on a 0mm wide chart. In-built text printing capabilities give clear annotation on the chart of time, date, scales and other process information. The clear view of process status from the l.c.d. display, with the simplicity of chart and pen replacement, make the SR0B extremely easy to operate. The recorder is designed for panel-mounting and provides IP (NEMA) dust and water protection on the front face, making it suitable for use in harsh environments. The SR0B can be configured for a wide range of input types and chart speeds and is ideal for most industrial recording applications. Application areas include: Heat Treatment eramics Manufacture old Storage Power Generation Process onnections Up to Universal Inputs Thermocouple RTD ma millivolts Volts Recorder Features Up to Traces hart Annotation Alarm Messages Time/Date Trace Indentifiers ma Transmitter Power Supply x Relay Outputs x 0mA Transmitter Power Supply RS Modbus RTU x Digital Input Standard Optional
3 Recording The OMMANDER SR0B s high-speed multi-point printing system updates all traces in. seconds. This system produces continuous lines on the chart at speeds of up to 00mm/hr. The printing sequence is intelligently managed by the recorder s control system to give priority to fast-changing signals, ensuring the most comprehensive process record is traced on the chart. The SR0B supports full text printing to provide detailed annotation on the chart. In addition to the time, date, channel identity and chart speed, the recorder can print scales for each channel, alarm messages and an Operator-entered batch name. The 'Easy-view' facility enables the user to see the latest recordings at the push of a button. Password protection prevents unauthorized access to the recorder s configuration. Quickly-fitted pen cartridges and an easily-removable chart cassette ensure simple and efficient pen and chart replacement. Set-up The OMMANDER SR0B can be easily set up to match your process in either of two ways: Entry of the correct password via the keypad on the front of the unit gives access to the recorder's configuration. A simple menu structure with clear text descriptions provides an intuitive approach to the recorder set-up. Unique Post-incident Analysis (ue-and-review) The OMMANDER SR0B s unique 'ue-and-review' facility allows the user to rapidly search any part of the roll chart for process events or alarm occurrence enabling rapid and accurate analysis of process records. Operation A graphic liquid crystal display (l.c.d.) provides exceptional clarity for day-to-day operation and for configuration. During normal operation the display cycles through each channel in sequence, showing the measured value, engineering units, description and channel identifier. lear text prompts on the l.c.d. display assist the Operator in accessing functions such as chart reload and alarm acknowledge. Tactile membrane keys on the front of the recorder are used to access these functions. A second, identical keypad is provided inside the recorder for use when the door is open. The preferred configuration method for multiple OMMANDER SR0B recorders is by means of the OMMANDER P onfigurator. This Windows -based package provides a simple 'point-and-click' approach to generating a full recorder configuration off-line. The completed configuration can be printed-out or saved onto disk before being downloaded to the recorder. A OMMANDER interface cable is used to provide the connection between the P s serial port and the configuration port on the recorder. Option Modules All recorders are fitted with at least one universal input module for analog process signals plus a transmitter power supply for up to two -wire transmitters. The capabilities of your recorder can be extended by the addition of further option modules. Each recorder can support up to input modules plus option modules. I/O Options Standard Option Universal Inputs or or Relays 0 Transmitter Power Supply (loops) Serial ommunications X
4 Application Function Overview V 0V 0:00 PaA PaA N The recorder prints time, date and chart speed automatically at regular intervals. hannel scales and batch identifiers can also be printed on the chart periodically or on demand. Up to process alarms can be set up within the recorder. Alarm status can be printed on the chart and the alarms can operate relay outputs or change the chart speed. A maximum of relays can be fitted within the recorder for use as alarm outputs. A single common relay can be set to be triggered by multiple alarms. A digital input is provided on every Input Module for remote changing of chart speed or for alarm acknowledgment. RS - or -wire communications using Modbus protocol provides a real-time link to SADA systems or PLs. Temperature Recording Recording of temperature, using both directconnected thermocouples and RTDs or -wire fieldmounted transmitters, is common in a wide range of industries such as Aerospace, ar component, Food, hemical and Kiln/Ovens. The SR0B can accept direct connection to all standard thermocouples, Pt00 resistance thermometers and to 0mA transmitters, and record on up to channels or datalog up to inputs. Operator messages allow printing of configurable messages such as 'Start of Test' or 'ycle omplete' for a clear record of the batch. For electric ovens fit the 00V isolator card to avoid conductance on the thermocouple which causes noise on the chart. OMMANDER SR0B Temperature Monitoring and Alarms In food production, it is essential to monitor the conditions in old Stores and Temperature-controlled Rooms to provide the user with a record that the goods have been stored at the correct temperature. The simplest and easiest way to do this is with the SR0B strip chart recorder, which can take up to inputs from RTDs spread across a cold store or a number of food preparation areas. Temperature Sensor onnections Loading and Unloading Bay Temperature Sensors (individual cable runs to the SR0B Recorder ensure accuracy and profile of store ) Racking and Storage Pallets At a chart speed of 0mm/hour, the unit provides recording for one month and, when fitted with relay output modules, provides alarm functions. Frozen Food Store (not drawn to scale as stores may be very large e.g. 0,000m and larger ontrol abin OMMANDER SR0B
5 Specification hart Traces Up to olors hannels to hannels to Magenta, Red, Black, Green, Blue and Brown Bi-color, Z-traces Pen life months typically (at 0mm/hr with normal scale printing) hart m Roll chart Quick-load cassette Standard chart graduation 00 divisions 0, 0, 0, 0 divisions also available hart speed onfigurable between and 00mm/hr in mm/hr steps Remote speed change Trace response.s for print-out of traces.s for print-out of traces Trace resolution 0.mm Text messages operator message for batch identification (0-characters) alarm messages (0 characters) Operation Graphics display backlit l.c.d. haracters 0.mm high process variables.mm high text Display of process variable Engineering range to Languages User-configurable for English, French or German Keys Sealed tactile membrane Analog Inputs duplicate keypads on door and inside case Number or Standard or Optional Input sampling rate ms per channel channels in.s Universally configurable for: Thermocouple (TH) Resistance thermometer (RTD) Millivolt, urrent, Voltage, Resistance Linearizer functions Programmable for all inputs including, x /, x / TH types B, E, J, K, R, S, T, L, N,or Pt00 Two 0-breakpoint custom linearizers Broken sensor detection Programmable to drive Upscale or Downscale RTD short/open circuit detection old junction compensation Automatic J incorporated as standard < 0.0 per (0. F per F)/change in ambient Input impedance urrent 0Ω Voltage 00kΩ mv & TH >0MΩ -wire transmitter power supply ma max. ( loops), fitted as standard. Additional loops can be powered from optional TXPSU modules Input hannel-to-channel V d.c. dielectric strength hannel to ground 00V d.c. dielectric strength ommon mode rejection > 0dB at 0/0Hz with 00Ω imbalance resistance Series mode rejection > 0dB at 0/0Hz Temperature stability 0.0% of reading/ (0.0% of reading/ F) or µv/ (µv/ F) (whichever is greater) Long term drift < 0.0% of reading or ±µv annually Filtering Off, to 0s digital filter Alarms high/low process alarms with programmable level and time hysteresis real-time events with programmable on-time and duration Electrical Power supply to V 0/0Hz V d.c. ±V (optional) Line interruption <0ms loss, no effect >0ms loss, auto-reset and restart Power consumption VA max Electrical safety EN00-, IE SA (optional) Electrical connections Screw terminals
6 Specification Option Modules - or -relay output module Universally assignable to any alarm signal Relay type Single pole changeover Voltage 0V a.c. 0V d.c. urrent A a.c. A d.c. Loading (non-inductive) 0VA 0W Note. The total load for all relays within the instrument must not exceed A. -wire transmitter power supply module Two isolated V outputs (ma each) Each output capable of driving loops RS serial communication (Modbus) module EIA communications standard RS (- or -wire) Protocol Modbus RTU (slave) Baud rate User selectable up to 00 Isolation 00V from rest of instrument Input Ranges and Accuracy Input Ranges Input Min. Value Max. Value Min. Millivolts Volts Milliamps Resistance Accuracy (% of reading) % o r ± 0µV % o r ± mv % o r ±µa % o r 0Ω Thermocouple and RTD Ranges and Accuracy Physical Size.mm (. in.) x mm (. in.) x 0mm (.00 in.) (depth behind panel) Weight < kg (lbs.) approx. Panel cut-out 0mm (. in.) x mm (. in.) ase material: Stainless steel, painted Door material Glass-filled polyarylamide Window material Polycarbonate Keyboard material Polyester Environmental Operating limits to 0 ( to F), Electronics < %RH (non-condensing) hart < 0%RH (non-condensing) Storage temperature limits 0 to 0 ( to F) Dust/Water protection Front face IP (NEMA) Rear of instrument IP0 Electromagnetic compatibility EN00-, EN00- E marked Vibration Designed to meet IE TH/RTD M in. Max. F Min. A ccuracy M in. Max. Min. Accuracy B 00 0 ±.0* 0 ±.* E J K L N R & S 00 0 * 0 0 ±.* T * For thermocouple types B, R and S performance accuracy cannot be guaranteed below 00 ( F). RTD * * * * ** For temperatures between 00 a nd 00 ( a nd F ) accuracy is ±. 0 ( ±. F).
7 Electrical onnections Note. Refer to instrument code for module positions A, B Analog Input onnector 0 0 Analog I/P rd lead RTD Analog I/P rd lead RTD Analog I/P rd lead RTD Analog I/P rd lead RTD Analog I/P rd lead RTD Analog I/P rd lead RTD Logic I/P 0V Instrument viewed from rear A B E F G H E, F Relay Output 0 0 N N N N N N Relay Relay Relay Relay Relay Relay E, F, G Transmitter d.c. Power Supply 0 0 H Power Supply V Spare Spare V L N E V 0V Line Neutral Earth a.c. d.c. -wire Transmitter d.c. Power G RS omms 0 0 TX -wire TX -wire Spare TX/RX -wire & RX -wire TX/RX -wire & RX -wire Spare ommon Overall Dimensions Dimensions in mm (in.). (.). (0.) 0.0. (.).0 (.) (. ) 0.0 (0.) with terminal cover fitted (. ) 0.00 Panel ut-out 0 (.) Note. Max. mounting angle 0 from vertical Accessories P onfiguration Kit part no. 00/000
8 Ordering Information OMMANDER SR0B Multipoint hart Recorder S R0B / XXS / X00 / X X X / X X X XX Number of Traces and Input hannels Build Option Module E Option Module F Option Module G ase Option hart Standard SA (pending) UL (pending) None relays relays Transmitter power supply unit None relays relays Transmitter power supply unit None Modbus serial comms. Transmitter power supply unit Standard panel mount Standard terminal cover P ower Supply V to V a.c. V d.c. onfiguration Roll chart ustom Standard complete onfiguration Details table below B U 0 T 0 T 0 S T M ST onfiguration Details For instrument configuration please complete this form and return it with your order. hannel 0 ST Input ma Linearization Units TH and Pt00 Linearizer Range Zero Zero Range ma, mv, V and Resistance Zero Display None Units e.g. e.g. ma H N one bar 0 T R 0 0 N ote. Default configuration is as ST above. The ompany's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB 000 Printed in UK (0.00) SS/SR0B Issue ABB Instrumentation Ltd Howard Road St. Neots, ambs. England, PE EU Tel: (0)0-- Fax: (0)0-- ABB Automation Inc Instrumentation Division E. ounty Line Road Warminster, PA USA Tel: Fax: -- ABB Instrumentation SpA Via Statale 0 Lenno (omo) Italy Tel: (0)- Fax: (0)-
Inform IT 250mm Multipoint Strip Chart Recorder
Data Sheet SS/_ Inform IT 0mm Multipoint Strip hart Recorder -channel recording on 0mm chart with individual trace colors Universal process inputs accepts thermocouples, RTDs, ma, mv & V lear text annotation
More informationUniversal Process Controller
Data Sheet SS/_9 Universal Process ontroller Single output, Heat/ool or Motorized Valve control one controller for every PID control application 9 program, segment Ramp/Soak comprehensive set point profiling
More information100mm Process Indicator Recorder
Data Sheet SS/_3 100mm Process Indicator Recorder One or two pen continuous line 100mm recorder universal input for thermocouple, RTD, mv, ma and V Clear, 5-digit LED display high visibility, wide viewing
More informationABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities
COMMANDER Universal Process Controller Specification DataFile PID controller with one shot autotune single loop, heat/cool and ramp/soak as standard Quick code, front face or PC configuration easy commissioning
More information250mm Advanced Process Recorder
Data Sheet SS/_4 0mm Advanced Process Recorder 4-channel recording on 0mm chart with individual trace colors Universal process inputs accepts thermocouples, RTDs, ma, mv & V Totalizers, math and logic
More information/8 DIN Universal Process Indicator
Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission
More informationC160 Wall-/Pipe Mounted Universal Process Indicator
Data sheet DS/ EN Rev. I Wall-/Pipe Mounted Universal Process Indicator reliable process indicator, wherever it s needed High visibility LED display the clearest view of your process status 0.1% measurement
More informationWall-/Pipe Mounted Universal Process Indicator
Data Sheet SS/_8 Wall-/Pipe Mounted Universal Process Indicator High visibility LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More information/8 DIN Motorized Valve Controller
Data Sheet SS/_5 Boundless motorized valve controller no need for slidewire feedback; improves reliability Two sealed 5A control relays suitable for direct connection to the valve, reducing installation
More informationInform IT Single Pen Circular Chart Recorder
Data Sheet SS/_ Inform IT Single Pen Circular Chart Recorder Universal process input ma, mv, V, thermocouples and resistance Signal linearization full range of linearizers included as standard -digit indicator
More informationABB Automation. Advanced Process Recorder COMMANDER SR100A. Specification DataFile. SR100A simplicity with power
OMMANDER SR1A Advanced Process Recorder Specification DataFile 1- to 6-trace recording on a 1mm chart continuous intelligent traces on a common time base Precision universal process inputs accepts thermocouples,
More informationControlMaster CM15 Universal process indicator, 1 /8 DIN. Making process control easy
Data sheet DS/CM15 EN Rev. E ControlMaster CM15 Universal process indicator, 1 /8 DIN Making process control easy Comprehensive display of process status Crystal-clear, full-color TFT display User-customizable
More informationFICHA TÉCNICA DE PRODUTO
FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:
More informationStrip Chart Recorders Specification Sheet
4101C, 4101M 4102C, 4102M MODELS Continuous Pen Recording 1, 2, 3 or 4 Pens Multi-point Recording Providing 6 Colour traces High Visibility Display 4101C, 4101M Clear Analogue Scale 4102C, 4102M Large
More informationABB Instrumentation. Specification DataFile. COMMANDER 1900 a rugged, reliable recorder with the full capability to meet your application needs
COMMANDER 00 Circular Chart Recorder Specification DataFile to pens full application flexibility NEMA X/IP construction hose-down protection Analog, relay outputs, digital inputs and transmitter power
More informationFICHA TÉCNICA DE PRODUTO
FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:
More informationC1900 Series Circular Chart Recorder. C1900 a rugged, reliable recorder with the full capability to meet your needs
Data sheet DS/C900R EN Rev. U C900 Series C900 a rugged, reliable recorder with the full capability to meet your needs to pen recording full application flexibility NEMA X/IP construction hose-down protection
More informationC1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument
Data sheet DS/C100 EN Rev. H C100 C100 dependable recording in a rugged, functional instrument High-definition backlit display latest LCD panel display technology ensures instrument operation and configuration
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. C1300 Advanced circular chart recorder
ABB MEASUREMENT & ANALYTICS DATA SHEET C100 Advanced circular chart recorder C100 ADVAN CED CI RCUL AR CHART RE CORDE R DS/C 1 00/U S-E N RE V. L Measurement made easy C100 dependable recording in a rugged,
More informationControl IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications
Data Sheet SS/C50_7 Control IT /6 DIN Controller/Alarm Unit C50 High visibility dual 4-digit display shows set point and process variable Standard relay or logic control output simple time proportioning
More informationC1300 Advanced Circular Chart Recorder. C1300 dependable recording in a rugged, functional instrument
Data sheet DS/C1300 EN US Rev. J C1300 C1300 dependable recording in a rugged, functional instrument High-definition backlit display latest LCD panel display technology ensures instrument operation and
More informationInform IT 100mm Advanced Process Recorder
Data Sheet SS/_4 Inform IT 100mm Advanced Process Recorder 1- to 6-trace recording on a 100mm chart continuous intelligent traces on a common time base Precision universal process inputs accepts thermocouples,
More informationControlMaster CM10 Universal process controller, 1 /8 DIN. Making process control easy
Data sheet DS/CM10 EN Rev. K ControlMaster CM10 Universal process controller, 1 /8 DIN Making process control easy Comprehensive display of process status Crystal-clear, full-color TFT display User-customizable
More informationControlMaster CMF160 Universal process indicator, fieldmount
Data sheet DS/CMF160 EN Rev. C ControlMaster CMF160 Universal process indicator, fieldmount Making process indication easy Measurement made easy Cost saving field-mount design Wall-, pipe- or panel-mountable
More informationC /4 DIN Multi-Recipe Profile Controller. C360 a comprehensive profile controller for all ramp/ soak applications
Data sheet DS/EN Rev. E a comprehensive profile controller for all ramp/ soak applications Dedicated for ramp/soak profile applications easy to use and follow customized display with direct control of
More informationSimplicity without Compromise. Specification DataFile. Ideal replacement for paper recorder simple, cost-effective solution
ScreenMaster 000 Videographic Recorder Specification DataFile Ideal replacement for paper recorder simple, cost-effective solution Robust and convenient archive storage low cost, high reliability, SmartMedia
More informationABB Instrumentation. Specifications. COMMANDER 505 Advanced Process Controller
Specifications COMMANDER 505 Advanced Process Controller Multiple PID control capabilities single loop, feedforward, cascade, feedforward with cascade, ratio, auto/manual station, analog backup, heat/cool
More informationInform IT Circular Chart Recorder/ Controller
Data Sheet Inform IT Circular Chart Recorder/ Controller to pen recording full application flexibility or controllers integrated control and recording Analog, relay outputs, digital inputs and transmitter
More informationDPR 100 A/B Analog Scales
DPR 100 A/B Analog Scales 0I-6030 8/95 Pen and Multipoint 100 mm Digital Recorders Specification and Technical Data Introduction The DPR 100 is a microprocessor based 100 mm (4 inch) strip chart recorder
More information- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS
ELK. ETK COMPACT BASIC CONTROL - SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS TIMER - SOFT START OUTPUT
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. ControlMaster CM10 Universal process controller, 1/8 DIN
ABB MEASUREMENT & ANALYTICS DATA SHEET ControlMaster CM10 Universal process controller, 1/8 DIN 2 CO N TRO LMASTE R CM10 UN I VERSAL PROC E SS CONTROLLE R 1/8 DIN DS/C M10-E N RE V. P Measurement made
More information1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882
1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature
More informationTRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
TRACKER 220 SERIES Digital Panel Indicators A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input Analogue Output
More informationThe Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement
Acquisition Measurement Control The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement TRACKER 220 SERIES INDICATORS Universal Input
More informationDINALOG A 144 x 36 A1400 Light-Strip Indicator
DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to
More informationControl IT Booster Pump Controller
Data Sheet SS/_4 Control IT Booster Pump Controller Protection for the pasteurization process ensuring a high quality, safe product for your customers High visibility LED displays continuous indication
More informationMRC 7000 Proven Recording Reliability that Became the Industry Standard!
Data Sheet Recorder//Profiler DESCRIPTION The MRC7000 Recorder/ is a microprocessor based circular chart instrument capable of measuring, displaying, recording and controlling up to two process variables
More informationDIGITAL INDICATING CONTROLLER
DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various
More informationIndicomp 4 Bargraph Indicator
Data Sheet 10/30-2.16-EN Indicomp 4 Bargraph Indicator Display is optionally LCD active: self-luminuous green on black self-luminuous green on blue LCD passive: self-luminuous black on light grey 2 input
More informationSX90 Process Controller
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationTemperature/Process Controllers Manual
3200 SERIES Temperature/Process Controllers Manual The innovative range of 3200 controllers offer precision control of temperature and other process variables together with a host of advanced features
More informationMODCELL 2050R Single Loop Controllers
Isolated universal process and remote set-point input Four internal set-points No jumpers required to define instrument parameters Ratio/bias on process and remote set-point Totalizer Ramp/soak profile
More informationDigital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free
Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard
More informationMTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits
830 SERIES Cuts installation and cable costs for all IS hazardous-area circuits Reduce the cost of installing hazardous-area cabling Save installation time, space and weight Highlight problems quickly
More informationScreenMaster RVG200 Paperless recorder. Measurement made easy. Secure process data at your fingertips
Data sheet DS/RVG200 EN Rev. B ScreenMaster RVG200 Paperless recorder Measurement made easy Secure process data at your fingertips High security data recording encrypted data storage compliant to 21 CFR
More informationField Mountable Videographic Recorder
Data Sheet 160002 Issue 2 Field Mountable Videographic Recorder A305! Unique universal mounting capability wall-, pipe- or panel-mount ultra-slim design, 90mm (3.5 in.) deep! Secure data recording large
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More informationEnergy Management Modular DC Energy analyzer Type VMU-E and VMU-X
Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.
More informationControlMaster CM30 Universal process controller, 1 /4 DIN. Making process control easy
Data sheet DS/CM30 EN Rev. D ControlMaster CM30 Universal process controller, 1 /4 DIN Making process control easy Comprehensive display of process status Crystal-clear, full-color TFT display User-customizable
More informationUSER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020
USER MANUAL MULTI COLOR MODEL : ARC2020 ACCSYS ELECTRONICS 140/6B, GOLDEN INDUSTRIAL ESTATE, JAWAHARLAL NEHRU ROAD, GERUGAMBAKKAM, CHENNAI - 600122 Tel: 044 60505599 / 60505511 E-mail : sales@accsyselectronics.com
More informationUDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationOBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal
More informationTRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features
TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation
More informationABB Instrumentation. Advanced Process Controller COMMANDER 505. Specification DataFile
COMMANDER 505 Advanced Process Controller Specification DataFile Multiple control capabilities single loop, feedforward, cascade, feedforward with cascade, ratio, auto/manual station, analog backup, heat/cool
More informationLBVR1718. Description. Features channel paperless recorder
LBVR1718 18 - channel paperless recorder Description It is the world first paperless recorder of the same size in highest resolution 640x480 pixels VGA TFT display, infrared detector, maximum 18 channels,
More informationDigital Indicator DS 48/24 E
Data Sheet 10/33-2.04-EN Digital Indicator DS 48/24 E The indicator is suitable for measuring direct voltage or direct current. The units are installed in a rugged plastic housing and can be integrated
More informationTC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.
LAUREL ELECTRONICS, INC. Laureate Thermocouple Panel Meter / Controller Features Factory calibrated for thermocouple types J, K, T, E, N, R, S Entire range of each thermocouple in one scale Highly accurate
More informationMLC 9000 Bus Compatible PID
MLC 9000 Bus Compatible PID Modbus, DeviceNet, Profibus Compatable The MLC 9000 is a unique, stand alone PID control solution to use instead of discrete DIN controllers. Reduce Wiring Costs Clean up the
More informationField Mountable Videographic Recorder
Data Sheet SS/SM500F Issue 8 Field Mountable Videographic Recorder SM500F Unique universal mounting capability wall-, pipe- or panel-mount ultra-slim design, 90mm (3.5 in.) deep Secure data recording large
More informationProcess controllers for the meat processing industry
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationControlMaster CM50 Universal process controller, 1 /2 DIN. Making process control easy
Data sheet DS/CM50 EN Rev. B ControlMaster CM50 Universal process controller, 1 /2 DIN Making process control easy Comprehensive display of process status Crystal-clear, full-color TFT display User-customizable
More informationUSER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series
USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series TEMPSEN DEVICES Plot No : 2&3, Balaji Nagar, 4 th Street, Mettukuppam, Thoraipakkam, Chennai-600097 Tele fax : +91-44-24581758,Mobil
More informationInform IT Multipoint Videographic Recorder
Data Sheet Inform IT Multipoint Videographic Recorder Large clear display 31cm (12.1 in.) thin film transistor (TFT) color screen Unsurpassed environmental protection hosedown to IP66 and NEMA4X standards
More informationDMT345 and DMT346 Dewpoint Transmitters
DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationDigital Indicator Solutions
Digital Indicator Solutions Loop-Powered Attachable Compact Attachable Loop-Powered Smart Compact System Loop-Powered Compact Smart System Intelligent Smart System "Intelligent" Options Dual & Display
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationLineMaster 100 Continuous-line Recorder
Data Sheet 10/43-1.10-EN LineMaster 100 Continuous-line Recorder 1... 4 measuring channels Format 144 mm x 144 mm, installed depth 250 mm Combined chart unit For roll chart (32 m) or folded chart paper
More informationControlMaster CM30 Universal process controller, 1 /4 DIN. Measurement made easy. Making process control easy
Data sheet DS/CM30 EN Rev. L ControlMaster CM30 Universal process controller, 1 /4 DIN Measurement made easy Making process control easy Comprehensive display of process status Crystal-clear, full-color
More informationTrident and Trident X2 Digital Process and Temperature Panel Meter
Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products
More informationUNIVERSAL TEMPERATURE TRANSMITTER
UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM210 is a universal transmitter
More informationPDW30 Point-To-Point Wireless Bridge
PDW30 Point-To-Point Wireless Bridge WIRELESS WIreless System FEATURES Wire Replacement in a Rugged, Industrial Housing Inputs and Outputs on Both Field Units Simple to Order, Configure, & Install 1 Mile
More informationAdvanced Videographic Recorder
Data Sheet Advanced Videographic Recorder Bright and clear display high contrast, thin film transistor (TFT) color screen Secure data recording 8Mb internal Flash memory for 2 recording channels and logs
More informationDATAWATCH IX MONITOR/RECORDER OVERVIEW FEATURES AND BENEFITS. Datasheet
OVERVIEW The DATAWATCH IX monitor offers an excellent graphical display and recording device for a box of its size. The compact panel mount unit offers four isolated or eight non-isolated high accuracy
More informationHigh Voltage DC Meter
High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationPowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006
PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationBatch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs
Datasheet N410 User-friendly batch controller Reliable Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Advantages Save time and cost with the easy to
More informationABB Easy Instrumentation. SM Series Videographic Recorders. A clearer view of your process. High visibility process displays
SM Series Videographic Recorders A clearer view of your process High visibility process displays ABB Easy Instrumentation remote access and operation via Ethernet communications High specification 21 CFR
More informationThe CAL range of temperature controllers
The CAL range of temperature controllers CAL Temperature Controllers Auto-tuning P.I.D. Controllers with RS232/485 Communication, Charting and Logging Software The CAL range of temperature controllers
More informationPaperless recorder Ecograph
Technical information TI075R/09/en Mat. no.: 51001521 Paperless recorder Ecograph Economical and time saving recorder operates without the need for paper or pens and is unusually simple to operate Application
More informationEnergy Management Modular DC Energy analyzer Type VIM-E and VIM-X
Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.
More informationInform IT Advanced Videographic Recorder
Data Sheet Inform IT Advanced Videographic Recorder Bright and clear display high contrast, thin film transistor (TFT) color screen Secure data recording 8Mb internal Flash memory for 12 recording channels
More information12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)
4-20 ma & Relay Output Features 4-20 ma, ± 10 V, TC & RTD Inputs 12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm) 24 VDC @ 200 ma Transmitter Power Supply Options Type
More informationPM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features
PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging
More informationUnitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000
Technical Specification Sheet Rev. 6, March, 2000 Unitary Controller The Unitary Controller can operate as an independent stand-alone controller, or can be connected to the APOGEE Automation System via
More informationPXR Series Advanced Self-Tuning Temperature and Process Controllers
PXR Series Advanced Self-Tuning Temperature and Process Controllers Key Features PID Description with fuzzy control of self-tuning 16 Ramp/soak segments Large LED display Auto-tune Timer function Heater
More informationHIGH-VOLTAGE DC METER
HIGH-VOLTAGE DC METER Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications
More informationCJ1W-PTS/PDC/PH41U/AD04U
CJ-series Process Analog I/O Unit A Single Unit Handling All Types of Inputs such as Temperature Sensor Inputs and Analog Signal Inputs (e.g., 4 to 20 ma or 1 to 5 V) A Unit supports four input channels,
More informationJUMO Quantum PID100/PID200/PID300
Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and
More informationAMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES
Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES Two cards providing 8 channels of temperature and process monitoring for VM 600 systems 8 channels of software selectable
More informationC100 Portable Multifunction
C100 Portable Multifunction Superior Accuracy as compared to Competitors! Wahl C100 Simultaneous Measurement and Generation Rugged IP54 Construction for On Site Use Quick Connect Terminals Measurement
More informationDPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2
Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationH3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.
H3 Series Dual-Line 6-Digit Temperature Meter Temperature J, K, T, E, R, S, B, N, C Thermocouples 100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 1 or 0.1 Resolution Averages up to 10 RTD Sensors
More informationKS 3012 PMA GENERAL DESCRIPTION
PMA KS 301 6 / 1 universal inputs 7 digital inputs Data acquisition with a sampling rate of 15 ms CF card as data storage medium Use as point or line recorder Visualization in up to 6 groups Modbus interface
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationIsolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated Voltage Input 3B30 / 3B31 FEATURES Interfaces, amplifies, & filtersanalog input voltages. Narrow-bandwidth (3Hz) single-channel single conditioning. Module provides simultaneous precision voltage
More informationCALYS 50. Field multifunction calibrator for basic use. Calibration measurement
for basic use Description is a basic multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field
More information