Communications & Networking
|
|
- Ellen Hill
- 5 years ago
- Views:
Transcription
1 8-Point Source Input & 8-Point Transistor Sink Output odule () Key features include: Communicate with network 8-point source input and 8-point sink output module Removable terminal blocks Use as remote I/O on ONC Input/Output Type Source Input/Sink Output Part Number SXS-SBK DC Input / Transistor Sink Output Type Part No. SXSSBK I/O Type Source input / sink output Input Input Logic Active Low Input Points 8 points No-voltage input Input Type (-wire DC sensor, 3-wire NPN sensor, no-voltage contact) Rated Input Voltage V DC Input Voltage Range 0 to the power voltage ON Voltage V maximum OFF Voltage 0V minimum Input Current ma/v DC Common common Output Output Points 8 points Output Type N-channel OS open drain Rated Voltage V DC Voltage Range 3 to 30V DC aximum Current 0.A/point Commons/Current common/a Short-circuit Protection No Current Draw 80 ma Terminal Arrangement Upper Terminal Block (SX9Z-SS) Communication Speed and Distance Bus Baud Rate Transmission Distance 00 kbps 00m (between slaves).8 km (total length) Communication Cable Network I/F Connector Bus (on the module) 9-pin D-sub connector Remote-in: ale Remote-out: Female Lower Terminal Block (SX9Z-SS3) Symbol Signal Symbol Signal CO () () CO () () 0 IN0 0 OUT0 IN OUT IN OUT 3 IN3 3 OUT3 IN OUT IN OUT IN OUT 7 IN7 7 OUT7 Communication Configuration Type No. ID Code Station Type Data Length Data Address SXS-SBK 03hex Remote Bus Station with Digital I/Os Byte 0 (Input) 7 0 byte (8 in / 8 out) Byte 0 (Output) USA: (800) -IDEC or (08) 77-00, Canada (888) 37-IDEC -3 Cable cable
2 General Information Wiring Cable Do not install the cable in parallel with or close to motor lines. Keep the cable away from noise sources. Turn power off before wiring the cable. ake sure of correct wiring before turning power on. Use a special cable and connect the cable as shown below. Use D-sub connectors made of metal or made of plastic with metallic plating. Connect the cable shield with the connector housing electrically. Cable Connector Pinouts ale Connector 9 Soldered Side /DO DO /DI 7 DI CO 3 9 Housing Green Yellow Pink Gray Brown Bridge pins and 9 inside the housing of the male connector. Female Connector /DO DO 7 /DI DI 3 CO 9 Housing Soldered Side 8-Point Source Input DC Brown (Red) 3-wire Sensor Black (White) NPN IN0 Output Blue (White) Brown (Black) DC IN -wire Sensor Blue (Black) Contact Switch IN Control Circuit Communication Interface DC Network Stripping and Clamping Cable Ends Contact Switch IN First, strip the cable sheath 0 mm from both ends of the cable and shorten the braided screen by mm. Bare the core ends 3 mm. Next, place the braided screen evenly around the cable sheath. Clamp the shield under the cable grip in the connector housing for conductive connection with the housing. 8-Point Transistor Sink Output Leave open the remote out connector at the last station in the network. Supply power to each slave station or to each group of stations separately. aster and slave stations may be powered up in any order. But, if a slave station is not powered up while the master is in preparation for transmission, a network error will result. Causes of network errors include disconnection or short-circuit of the network cable, strong external noise, invalid command sent to the master station, momentary power voltage drop below the minimum power voltage, faulty transmission line, incorrect cable, and transmission longer than the rated distance. When a network error occurs, all outputs are turned off. For further information on, read documents published by the CLUB. - USA: (800) -IDEC or (08) 77-00, Canada (888) 37-IDEC DC Network Communication Interface Control Circuit OUT0 OUT OUT7 Relay Relay Pilot Light
3 is a network originally developed for controlling sensors and actuators. The system is a data ring with a central master-slave access method. It has the structure of a spatially distributed shift register. Every module forms with its registers a part of this shift register ring through which the data is shifted serially from the host controller board. The use of the ring topology in this way offers the possibility of sending and receiving data simultaneously (full duplex) and leads to better diagnostic possibilities when compared to a bus structure. To simplify system installation, the ring is implemented within one cable line (go and return line within one cable). The system therefor appears as a bus system with branching lines (tree structure). Part Numbers Part Numbers: Bus Type Specifications Part No. aster aster odule ONC Remote I/O aster odule FC3A-SXS -point source input (V DC) SXS-SBNS DC Input -point sink input (V DC) SXS-SBNK Relay Output 8-point relay output (0V AC/V DC, A) SXS-SBR08 -point transistor sink output (V DC, 0.A/point,.0A/common) SXS-SBTK Transistor Output Remote I/O -point transistor protect source output (V DC, 0.A/point,.0A/common) SXS-SBTP DC input Transistor Output 8-point source input (V DC) 8-point transistor sink output (V DC, 0.A/point,.0A/common) 8-point sink input (V DC) 8-point transistor protect source output (V DC, 0.A/point,.0A/common) SXS-SBK SXS-SBP Accessories Accessories Name Description Part No. Terminal Block Upper terminal block for SX*-SBN*, -SBT*, -SB* SX9Z-SS Terminal Block Lower terminal block for SX*-SBN*, SBT* SX9Z-SS Terminal Block 3 Lower terminal block for SX*-SB* SX9Z-SS3 Terminal Block Upper terminal block for SX*-SBR08 SX9Z-SS Terminal Block Lower terminal block for SX*-SBR08 SX9Z-SS DIN Rail Aluminum (m) 3-mm-wide DIN rail BNDN000 Aluminum (m) 3-mm-wide DIN rail BAA000 ounting Clip Used on DIN rail to fasten SX communication terminals BNL One upper and one lower terminal blocks are supplied with every SX communication terminal USA: (800) -IDEC or (08) 77-00, Canada (888) 37-IDEC -
4 SX General Information The OpenNetController uses the open network to set up a remote I/O system which makes it the master in the network. Input data from a remote I/O slave station is stored to link registers allocated to input data in the OpenNet Controller. Since I/O data is stored in link registers and transferred automatically, no communication program is required to send and receive I/O data between the master and slave stations. I/O connection is just as easy as ordinary digital I/O connection. Remote I/O System Setup Remote I/O aster odule FC3A-SXS Remote I/O aster Station RUN ERROR HSC OUT Cable ale Connector V. Interface REOTE OUT idec CO A B Z HSC RS8 OUT A B G V 0V Female Connector REOTE OUT REOTE IN SXS UL RC BA ER RD Node 0 Total Cable Length 00m 3 =.8 km (7.9 miles) maximum REOTE OUT REOTE IN REOTE OUT REOTE IN SXS SXS UL RC BA ER RD UL RC BA ER RD Node Node N (N 3) Remote I/O Slave Stations IDEC s SXS Communication I/O Terminals for. Other vendor s slave modules (remote bus stations) are also applicable. input and output points per slave station at the maximum. General Specifications Rated Voltage Allowable Voltage Range I/O Control Circuit Isolation Control Circuit Comm. Interface Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Damage Limits Operating Extremes (relay output) Damage Limits Operating Extremes (relay output) Operating Temperature Operating Humidity Storage Temperature Storage Humidity ounting Weight (approx.) V DC 9 to 30V DC (including % ripple) Not isolated, DeviceNet,Photocoupler LonWorks:Transformer coupling Between power terminals and ground: 00 Ω minimum (00V DC megger) Between power terminals and ground: 000V AC, minute Between relay outputs and other live parts: 000V AC, minute Amplitude: 0.3 mm, 0 to Hz Amplitude: 0.3 mm, 0 to Hz (contact opening msec when energized) 9 m/sec, m/sec, sine half-wave pulse 9 m/sec (in the direction of relay contact movement) 98 m/sec (in other directions) 0 to C 30 to 90% RH (non-condensing) 0 to 7 C 30 to 90% RH (non-condensing) Snap-on mount on 3-mm DIN rail Panel-mount with screws 80g - USA: (800) -IDEC or (08) 77-00, Canada (888) 37-IDEC 9mm (0.7in) 3.mm (0.in) 7mm (.9in) 3mm (.in) 8mm (.89in) 9.3mm (0.7in)
5 SX Smart I/O General SX Series Smart I/O (General Information) Wiring SXD and SXL Cable Connector For wiring the communication cable connector on the SXD and SXL, use a cable of AWG to AWG (0. to. mm ). Strip the cable 7 mm from the end as shown below. Each communication terminal can accommodate up to two cables. Terminal Symbols SX*-SBR08 0 C0 C C 3 C3 SX*-SB* SX*-SBN*/SBT* mm When connecting two cables to one terminal, use cables of AWG to AWG (0. to. mm ). Do not solder the cable end for connection. Tighten terminal screws on the communication cable connector to a torque of 0. to 0. N-m. Tighten mounting screws on the communication cable connector to a torque of 0.3 to 0. N-m. When tightening the screws on the cable connector, use a Insertion Pin Positions When purchasing terminal blocks separately, set the insertion pins as shown below. A B C D E F G H SX*-SBN*/SBT* SX*-SB* SX*-SBR08 ounting Hole Layout (Top view) C (3.9in ± 0.0) (.3in ± 0.0) 00mm 0. 33mm 0..mm (0.8 in) C C 7 C7 A B C D E F G H SX Type No. Terminal Block Type No. Pin Positions SX*-SBN* SX*-SBR08 SX*-SBT* SX*-SB* Upper SX9Z-SS B D F H Lower SX9Z-SS A C E G Upper SX9Z-SS B D E G Lower SX9Z-SS A C F H Upper SX9Z-SS B C E G Lower SX9Z-SS A D F H Upper SX9Z-SS B C F H Lower SX9Z-SS3 A D E G Safety Precautions Turn power off to the SX communication terminals before starting installation, removal, wiring, maintenance, and inspection of the SX. Failure to turn power off may cause electrical shocks or fire hazard. Wire the SX correctly. Improper wiring may cause malfunction, abnormal heat, and fire hazard. Use wires of a proper size to meet voltage and current requirements of the SX. Tighten the terminal screws to a proper tightening torque. A loose screw may cause abnormal heat and fire hazard. Check periodically to see if the screws are tightened securely. All SX communication terminals are manufactured under IDEC s rigorous quality control system, but users must add a backup or fail safe provision to the control system using a SX communication terminal in applications where heavy damage or personal injury might result should the SX fail. USA: (800) -IDEC or (08) 77-00, Canada (888) 37-IDEC -3 (.3in ± 0.0) 0mm 0. (.97 in min) 0mm min.
6 SX Smart I/O General Input/Output Requirements When connecting DC two-wire sensors to the SX, the sensors must meet the following specifications. Operating voltage: to V DC Leakage current: ma maximum Residual voltage: V maximum ON output current:. ma minimum (at V DC) The sensor must have an ON output current of ma at the minimum. If the sensor does not meet this lower limit, connect a bleeder resistor as shown below. But if the residual voltage is V or less, the sensor can still be used although the ON output may be less than 3. ma. Source Input Type Input R DC two-wire sensor I Sink Input Type Input Use the following formula for calculating the bleeder resistance if needed. Vcc R (kω) = I Vcc: voltage I:Lower limit of DC two-wire sensor ON output (ma) Do not apply a DC power voltage to the output circuit without connecting a load, otherwise internal elements will be damaged (except for the protect source output type). When an overload or short circuit occurs, the protect source output shuts down the output immediately to protect the internal elements from permanent damage. When the cause of the overload or short circuit is removed, the SX will restore normal operation automatically. When the capacity of main power supply is small, the overcurrent protection of the main supply may reduce power supply to the SX, then the SX will stop operation, causing a network error. When using the relay output in environments where extraneous noises exist or inductive loads are switched frequently, generating high reverse emf, connect contact protection elements to the output terminals and across the load as shown below. Varistor System SX*-SBR08 C0 OUT0 For both AC and DC power voltages Response Time The response time of the SX system varies greatly depending on such factors as the quantity of modules and cable length. The accurate response time can be confirmed on the actual network system. Terminators DeviceNet and LONWORKS networks require terminators. For details about the terminators, see publications on DeviceNet or LONWORKS, or consult IDEC. R DC two-wire sensor Diode and Zener Diode System SX*-SBR08 C0 OUT0 I For DC power voltage only Operating Instructions Installation and Wiring (All SX odules) Turn power off to the SX before installing or removing the connector or the detachable terminal block. Tighten the terminal screws to a torque of 0. to.0 N-m. When mounting the SX on a panel, tighten the mounting screws to a torque of.0 to.3 N-m. Recommended mounting screw: When mounting the SX on a 3-mm-wide DIN rail, put the SX on the DIN rail and press the SX towards the rail to lock. To remove, pull out the latch from the bottom of the module using a screwdriver and release the SX. To re-attach, push back the latch into place and snap on the SX again. The upper-right mounting hole has a FG terminal. Connect the FG terminal and control box. Use a wire of mm at the minimum to connect the relay terminal block with the safety ground. When mounting on a 3-mm-wide DIN rail, a steel DIN rail is recommended for easy grounding. ounting on Steel DIN Rail IDEC Part Number BAP000 (Recommended) A metal grounding clip is provided on the back of the SXS and SXL to contact with a DIN rail. When mounting the SX on a steel DIN rail, the metal grounding clip comes in electrical contact with the DIN rail. Connect the DIN rail to a proper ground. ounting on Aluminum IDEC DIN Rail Part Number BNDN000 The upper-right mounting hole has a FG terminal. When mounting the SX on an aluminum DIN rail, connect the FG terminal to the panel using the attached screw and nut, and connect the panel to a proper ground. Panel ounting When mounting the SX on a panel surface, attach a crimping terminal of a grounding wire to the FG terminal on the upper-right mounting hole of the SX, and insert a screw through the mounting hole. Connect the grounding wire to the panel and connect the panel to a proper ground. Note: For secure electrical connection, remove coating from the grounding area on the panel. Terminal Block The SX uses detachable terminal blocks. To remove and attach the terminal block, follow the procedures below. To remove the terminal block, squeeze both latches on top of the block inward to unlock the block from the socket. To reattach the terminal block, place the block in the socket with the latches opened and press the block until it bottoms in the socket, then the latches snap outward to lock the terminal block. Insertion pins are positioned on the base of the terminal block and inside the socket to prevent insertion of invalid blocks into the socket. The pins are keyed to ensure correct matching of block and socket, and prevent swapping of upper and lower blocks. When the block does not fit into the socket properly, check to see if the pin positions on the block agree with the pin-slot arrangement in the socket. If the pins and the pin slots are in matching positions, check for any chips and obstacles in the socket. When cutting cables or wires, keep the SX out of the way to prevent ingress of wire chips and fragments. When wiring the screw terminals using crimping terminals, use crimping terminals of the dimensions shown below. Each screw terminal can accommodate up to two crimping terminals. Note: Spade crimping terminals can also be used. - USA: (800) -IDEC or (08) 77-00, Canada (888) 37-IDEC max. ø3. min. 3.0 max.. min. (Dimensions are in mm)
Communications & Networking
is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave
More informationSuitable for detecting transparent films or transparent bottles
Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16
More informationCommunication & Networking
MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators
More informationSafety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide
Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed
More informationRelays & Sockets RR Series Power Relays. Part Number Selection
RR Series Power Relays Key features: SPDT through PDT, A contacts Midget power type relays Available in pin and blade terminal styles. Options include an indicator, check button for test operations and
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationRelays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection
Q Series Q Series PB elays Switches & Pilot Lights Display Lights IDE Q relays are low-profile, PB relays that provide quality within a compact package. Size equals value. Q relays are small, yet maintain
More informationPHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.
INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationIBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description
IBS ST 24 BK-T Data Sheet INTERBUS-S Bus Terminal Module Data Sheet Revision A 08/994 Product Description The IBS ST 24 BK-T bus terminal module is the head station for an INTERBUS ST compact station in
More informationSafety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide
Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed
More informationOptimum sensing capability for LCD manufacturing
SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationPS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.
Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized
More informationCommunications & Networking LONWORKS
LONWORKS IDEC SmartRelay LONWORKS Communication odule Part Numbers Item LonWorks Communication odule FL1B-CL1C12 Part Number LonWorks Communication odule User s anual available for download at www.idec.com/usa
More informationProgrammable Logic Controllers
OpenNet Controller FCA-CPK FCA-CPS OpenNet Controller (with memory card connector) Flash memory card ready Digital I/O -,, and point cards - inputs and outputs, with expansion power supply Analog I/O -
More informationAS-Interface Safety at Work
Safety Emergency Stop Switches... 478 Operating Instructions... 482 www.idec.com/safety AS-Interface Safety at Work Light Curtains Table of Contents LED Lighting - Pg. 1 Automation & Sensing - Pg. 21 Safety
More informationDIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C
RTE Series DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance
More informationPage Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W
Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN
More informationTerminal block 2 A 5 X 3. Specification
D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables
More informationEF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!
1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible
More informationINSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers
2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for
More informationCompact Inductive Proximity Sensor
SERIES Compact Inductive Proximity Sensor Amplifier Built-in High functionality together with robust housing and flexible cable Miniature is an amplifier built-in inductive proximity sensor having a diameter
More informationInstallation Sensing distance Connection Output configuration Operation mode NO Operation mode NC
Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationIntrinsically Safe Explosion Proof Barriers
Safety Intrinsically Safe Explosion Proof For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos &
More informationOpenNet Controller. Electrical Specifications. Hardware Features. ONC Capabilities
OpenNet Controller Electrical Specifications FCA-CPK, -CPKM* FCA-CPS, -CPSM* Rated Voltage Maximum Input Current Reverse Polarity Protection Operating Temperature Storage Temperature Relative Humidity
More informationTimers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours
GT3W Key features: Sequential start, sequential interval, on-delay, recycler, and interval ON timing functions 2 time settings in one timer 8 selectable operation modes on each model Mountable in sockets
More informationMODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously
More informationMODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to
More informationProgrammable Logic Controllers
OpenNet Controller UL Listed File #E Programming Software; WindLDR Programs all IDEC PLCs Windows-based (compatible with Windows,,, NT., ME, XP or Vista) Digital I/O -,, and point cards - inputs and outputs,
More informationGX SERIES. Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. Robust enclosure and flexible cable types are also available
8 Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.86~ selection guide... P.757~ General precautions... P.05 PHOTO PHOTO Conforming
More informationCylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global
8 PHOTO PHOTO MEASURE Cylindrical Compact Inductive Proximity SERIES Related Information General terms and conditions... F- Glossary of terms... P.576~ panasonic.net/id/pidsx/global guide... P.78~ General
More informationOperation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit
Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications
More informationExpansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157
PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or
More informationE2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1
Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the
More informationGX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.
DC 2-wire Cylindrical Inductive Proximity SERIES Amplifier Built-in High performance & ease of use Robust in tightening The tightening torque has been improved to approx. four times greater than that of
More informationDIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.
Ethernet Remote I/O F&eIT N Series Isolated Digital / DIO-1616LN-FIT * Specifications, color and design of the products are subject to change without notice. This product is an isolated digital input and
More informationCommunication & Networking
SXA AS-Interface SXA AS-Interface (Communication Terminal and Repeater) AS-Interface Communication Terminals (Slave Modules) IP67 I/O Module AS-Interface Ver.. compliant, capable of connecting 6 slaves
More informationDC 2-wire Cylindrical Inductive Proximity Sensor
SERIES DC -wire Cylindrical Inductive Proximity -wire type available Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance & ease of use G-8/8U GA-/GH GX GX-N G-8H/8H G-N Robust
More informationGL SERIES. Compact & Low Price Inductive Proximity Sensor. Wide variety, high performance in surprisingly small body at low cost.
811 Compact & ow Price Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.176~ guide... P.781~ General precautions... P.179~ PHOTO PHOTO MEASURE
More informationUltra Slim Relays 24
Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest
More informationSwitches & Pilot Devices
Key features: 21/64 (8mm) round mounting hole Compact Design Saves Space Bright and Vivid Illumination Choice of Shapes and Functions old Clad Silver Contacts for reliable low level switching Snap action
More informationPRODUCT SPECIFICATION. PC Board Relays. Series.
PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7
More informationDC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range
INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price G-8/8U GA-/GH GX GX-U/FU
More informationRF1V Force Guided Relays SF1V Relay Sockets
FV Force Guided elays SFV elay Sockets www.relays.de EN00 Typ A TÜV-Zulassung von 8 Enables flexible construction of safety circuits Complies with International Standards Force guided contact mechanism
More informationModel Number Structure
Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater
More informationG3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE
Solid State Relay G3NE Compact, Low-cost, SSR Switching 5to20A D Wide load voltage range: 75 to 264 VAC. D Dedicated, compact aluminum PCB and power elements used. D Built-in varistor effectively absorbs
More informationG3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend
Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures
More informationGA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability
82 PHOTO PHOTO Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.86~ Sensor selection guide... P.757~ General precautions...
More informationDC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range
INDUCTIVE SERIES DC 3-wire Cylindrical Inductive Proximity Oil resistant Metal embedding possible Amplifier Built-in GX G-6 High performance and environmental resistance at low price GA-/GH GX GX-U/FU
More informationS8VE (60/90/120/180/240-W Models)
Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,
More informationBarriers. EB3N Discrete Input Barrier with Redundant Output
EB3N Discrete Input Barrier with Redundant Output s Build a safety system in an explosive atmosphere. Key features: Safety Performance Performance level e Category 4 [Exia] II C Ensures safety and machine
More informationSYSMAC Remote Transistor Module
9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models
More informationGA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations
875 PHOTO PHOTO IT FOW PARTICUAR Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.482~ Sensor selection guide... P.80~
More informationTwido Programmable Controllers Discrete I/O Modules
Twido Programmable Controllers Discrete I/O Modules Hardware Guide 03/2007 www.telemecanique.com 2 Table of Contents Safety Information....................................5 About the Book.......................................9
More informationPower Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number
Standard Series Key features: Wide power range: 7.W-24W Universal input : 7.W-W: 8-264V AC/1-37V DC 1W: 8-2V AC/17-264V AC 24-37V DC (selectable) W, W, 24W: 8-264V AC/11-3V DC Overcurrent/overvoltage protection
More informationTABLE OF CONTENTS. Communication Functions
TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................
More informationTCNM-ACBB1 Installation Manual
The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is
More informationInductive Proximity Sensor
Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.
More informationEtherCAT Remote I/O Terminal GX series
EtherCAT Remote I/O Terminal GX series Digital I/O Terminal 2-tier Terminal Block Type Digital I/O Terminal 3-tier Terminal Block Type Digital I/O Terminal e-con Connector Type Analog I/O Terminal 2-tier
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing
More informationTimers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum
GT5Y GT5Y Series ON Delay Key features: 4PDT, 3A or DPDT, 5A contacts 4 time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED indicators Uses the same
More informationModbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information
RM Series Modbus Digital Remote I/O Modbus Connector Type Digital Remote I/O Features Modbus RTU standard protocol Connects with sensor connector, e-con: saves wiring work (sensor connector, CNE Series,
More informationCombine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.
9 Relay I/O Block Reduces Wiring within the Control Panel and Reduces Installation Time 1 Compact 16-pt models: 182 W l 85 D l 68 H mm; 8-pt block width is 102 mm 1 Can be connected to the PLC with a connecting
More informationPRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I
PRCM Series Cylindrical Connector Type Proximity Sensor Features Improved the noise immunity with dedicated IC Built-in reverse polarity protection circuit (DC -wire type) Built-in surge protection circuit
More informationSeries LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver
Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided
More informationTimers. RTE Series. RTE Series Analog Timers. Specifications. G-8 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC
Analog Timers Key features of the RTE series include: time ranges and timing functions ON-delay, interval, OFF-delay, one-shot Time delays up to 0 hours Space-saving package (." x." x.0") High repeat accuracy
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description
Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS
More informationDIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E
INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for
More informationGT3F Series True OFF Delay Timers
TF Series TF Series True OFF Delay Key features of the TF series include: Mountable in sockets or flush panel True power OFF-delay up to 10 minutes No external control switch necessary Available with reset
More information4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm
Inductive Sensor Double Sensing Distance Model Number Legend SALIENT FEATURES IP - 7, Brass Housing Short - Circuit protection Reverse Polarity Protection Shielded and Non - Shielded Prewired and Connector
More informationRTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)
Analog Key features of the RE series include: 0 time ranges and 0 timing functions ime delays up to 600 hours Space-saving package High repeat accuracy of ± 0.% ON and timing LED indicators Standard 8-
More informationOiltight Switches & Pilot Devices
LED and Incandescent ilot Lights (Sub-Assembled) Removable Terminal* + Operator + Lamp + Lens = Completed Unit * Removable terminals are applicable for CB terminated types only. art Numbers: ilot Light
More informationPlug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs
1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationFrom ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets
1135 Detector SERIES Related Information General terms and conditions... F-3 General precautions...p.1595 PHOTO PHOTO MEASURE From ultra-thin lead frames to iron sheets... Double feed detection of various
More informationPRD/PRDW Series. Long Distance Type
Long Distance Type Long distance proximity Features Long sensing distance (. to times longer sensing distance guaranteed compared to existing models) Improved the noise resistance with dedicated IC Built-in
More informationModel Number Structure
Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum
More informationIO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs
IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,
More informationConnector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable
44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in
More informationOiltight Switches & Pilot Devices
ø22mm - LW Series Oiltight LED and Incandescent Illuminated ushbuttons (Assembled) art Numbers: LW1L/LW2L Illuminated ushbuttons (LED and Incandescent) art Number Contact Style Contact Momentary Maintained
More informationSwitching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply
Switching Power Supply Compact and Economical Switching Power Supply Models range from 10 to 50 W Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved
More informationCapacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
More informationInterlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches
HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for
More informationTimers NEW DESIGN! RTE Series. RTE Series Analog Timers
RE Series imers RE Series Analog imers NEW DESIN! Key features of the RE series include: 0 time ranges and 0 timing functions ime delays up to 600 hours Space-saving package High repeat accuracy of ± 0.%
More informationAppearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC
Interface Converter A compact converter that allows communications between RS-C/USB and RS-/8 devices. Ideal for industrial applications. Allows communications between RS-C/USB (Universal Serial Bus) and
More informationover time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri
Figure 3.14 Main speed frequency reference. Multi-function programmable Safety input Forward run/stop Reverse run/stop External fault Fault reset Multi-step speed 1 main/aux switch Multi-step speed 2 Jog
More informationRM84 miniature relays
RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to
More informationFrom ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets
1147 Detector SERIES Related Information General terms and conditions... F-7 General precautions...p.151 PHOTO PHOTO MEASURE ITY From ultra-thin lead frames to iron sheets... Double feed detection of various
More informationCapacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
More informationPart Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.
MicroSmart FC6A PLC CPU Module Specifications KEY FEATURES Embedded Ethernet port Embedded SD memory port Modbus TCP and RTU Embedded RS232C/RS485 user selectable Maximum 520 digital I/O Maximum 126 analog
More informationPC RELAY TERMINAL/ PC TERMINAL
Input points Output points PC Relay (PC relays mounted) PC Input points Output points Input points Output points Input points Output points Input points Output points Output points ORDERING INFORMATION
More informationEE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety
Compact for High-Density Mounting with Easy Snap-In Connector H Connector features a built-in safety lock for shock and vibration resistance H replacement made simple without rewiring H Cables can be bent
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More information-ment Ambient humidity 35 to 95%RH, Storage :35 to 95%RH
PRD/PRDW Series Long Distance type Long distance proximity Features Long sensing distance (. to times longer sensing distance guaranteed compared to existing models) Improved the noise resistance with
More informationT imers Timers Selection Guide Timing Diagrams Overview RTE Series Analog Timers Instructions onlinecomponents.com IDEC.
Industrial Automation Catalog Section - U906 imers Selection uide iming Diagrams Overview RE Series Analog imers Instructions imers For up-to-date information, or to request a full copy of this catalog,
More informationKCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings
for Display of High-speed Addition and Subtraction Maximum operating speed 2kHz Used in industrial machinery, end-measuring devices, and the like, this electronic counter is exclusively for display. It
More information