Communication & Networking

Size: px
Start display at page:

Download "Communication & Networking"

Transcription

1 SXA AS-Interface SXA AS-Interface (Communication Terminal and Repeater) AS-Interface Communication Terminals (Slave Modules) IP67 I/O Module AS-Interface Ver.. compliant, capable of connecting 6 slaves Compatible with - and -wire s With AS-Interface power and input status indicators Overload detection function on the power supply overload detection function ( in/ out model, in/ out model) IP0 Terminal Block AS-Interface Ver.. compliant, capable of connecting 6 slaves Removable terminal blocks Compatible with - and -wire s AS-Interface power and input status indicators IEC606- compliant Repeater No address setting required. The AS-Interface network can be extended up to 00 m. IP6 protection Easy connection to AS-Interface fl at cables. SXA AS-Interface Communication Terminals IP67 I/O Module IP0 I/O Module Base Modules Base Module for IP67 I/O Module Repeater Terminal Connector Terminal Block Description A repeater can extend the AS-Interface Network up to 00m. Part Numbers I/O Specifications Points Points Part Numbers Applicable Base Module (order separately) NPN SXA-SWN0S0 SXA-BFF PNP SXA-SWN0K0N SXA-BFF PNP PNP SXA-SWMKSN SXA-BFF PNP PNP SXA-SWMKSN SXA-BFF NPN SXA-SSN0S0N PNP SXA-SSN0K0N PNP PNP SXA-SSMKSN Applicable I/O Module Description Part Numbers in model SXA-BFF in/ out model Substructure module to connect to AS-Interface flat cables for AS-Interface bus and auxiliary power in/ out model SXA-BFF SXA-RP Part Number PLCs Operator Interfaces Automation Software Power Supplies Sensors USA: IDEC Canada: IDEC

2 SXA AS-Interface Accessories Description Part Numbers Notes PLCs Hand-held Programming Device Assign slave addresses and monitor system configuration SX9Z-ADRN Includes: Programming device cable (SX9Z-CN) Programming device AC adapter (SX9Z-ADPT) SwitchNet addressing port adapter (LA9Z-SNADP) Operation manual (English/Japanese) Programming Device Cable Connect the programming device to slave SX9Z-CN Operator Interfaces Programming Device AC Adapter SwitchNet Addressing Port Adapter Charge the programming device SX9Z-ADPT AC input voltage: 00 to 0V AC Connect the programing device cable to SwitchNet contacts LA9Z-SNADP AS-Interface Flat Cable Branch Connector Branch AS-Interface flat cable to AS-Interface flat cable SX9Z-CF Automation Software T-branch Connector M Branch Connector Branch AS-Interface flat cable to -wire cable Branch AS-Interface flat cable to M cables LA9Z-SNTB SX9Z-CT Power Supplies AS-Interface Flat Cable End Tube Protection Cap Protect the end of AS-Interface cable SX9Z-CPA Degree of protection: IP6 Ensure IP67 protection on unused M I/O plugs SX9Z-CAP Sensors 6

3 SXA AS-Interface IP67 I/O Module AS-Interface Ver.. compliant. A maximum of 6 slaves can be connected. SXA-SWN0S0 is a Ver..0 standard slave, which allows for connection of up to slaves. Compatible with - and -wire s With AS-Interface power and input status indicators Overload detection function on the power supply overload detection function ( in/ out model, in/ out model) IEC606- compliant Specifications General Communication Models SXA-SWN0S0 SXA-SWN0K0N SXA-SWMKSN SXA-SWMKSN Rated Operating Voltage (Ue) Rated Operating Current (Ie) External Auxiliary Power Supply U (AUX) Operating Temperature Storage Temperature Degree of Protection 0mA (without ) 0mA maximum 6. to.6v DC supplied from AS-Interface line to +60 C (no freezing) to +8 C (no freezing) 0mA (without ) 0mA maximum 0mA (without ) 0mA maximum 0 to 0V DC LV (protective very-low voltage: protection class VDE006 / IEC606-- compliant) IP67 (EN609); Attach SX9Z-CAP protection caps on unused I/O connectors. Connection Method Insulation displacement technology for flat cables (yellow/black) M connector for I/O Weight 00g 0g Mounting Method Screw mounting on base module Points/Signals Power DC inputs - and -wire s (NPN) 00mA (Tb 0 C) 0mA (Tb 60 C) DC inputs - and -wire s (PNP) DC inputs - and -wire s (PNP) 0 to V DC supplied from AS-Interface line 00mA (Tb 0 C) 7mA (Tb 60 C) Load Current Capacity Provided with overload and short-circuit protection OFF Current OFF ma OFF ma ON Current (sink) ON.mA ON ma Protection Circuit current limit 8mA Points/Signals PNP transistor s (with overload/short-circuit protection) DC inputs - and -wire s (PNP) 00mA (Tb 0 C) 0mA (Tb 60 C) PNP transistor s (with overload/short-circuit protection) Power Supplied from external auxiliary power supply U (AUX) Voltage External auxiliary power voltage U (AUX) 0.V A (OUT, ).A Current A per point (OUT) A total Communication Error turns off Profile Slave Type Standard slave A/B slave Data Bits D0 D D D IO 0 0 B 7 ID A A A ID OUT OUT OUT PLCs Operator Interfaces Automation Software Power Supplies Sensors USA: IDEC Canada: IDEC 7

4 SXA AS-Interface PLCs Operator Interfaces Specifications LED Indicators Address Models SXA-SWN0S0 SXA-SWN0K0N SXA-SWMKSN SXA-SWMKSN AS-Interface power: Green LED AUX External auxiliary power U (AUX): Green LED yellow LEDs yellow LEDs yellow LEDs OUT yellow LEDs yellow LEDs Addressing Method Certification Standards Error indication: Red LED ON: Communication error or address 0 Flash: Sensor power supply or is overloaded Remove the protection cap from the addressing port on the I/O module. Connect the hand-held programming device (SX9Z- ADRN) to the addressing port on the I/O module using the programming device cable (SX9Z-CN), then the I/O module stops communication through the AS-Interface line. Change slave addresses using the programming device. AS-International Association UL/c-UL, CE Sensors Power Supplies Automation Software 8

5 SXA AS-Interface IP0 I/O Module AS-Interface Ver.. compliant A maximum of 6 slaves can be connected. Removable terminal blocks Communication monitor function Compatible with - and -wire s AS-Interface power and input status indicators IEC606- compliant Specifications General Communication ModelsSXA-SSN0S0N SXA-SSN0K0N SXA-SSMKSN Rated Operating Voltage (Ue) 6. to.6v DC supplied from AS-Interface line Rated Operating Current (Ie) 0mA (without ) ma (without ) External Auxiliary Power Supply U (AUX) Operating Temperature Storage Temperature Degree of Protection Connection Method Weight Mounting Method Points/Signals Power Load Current Capacity OFF Current ON Current (sink) DC inputs, - and -wire s (NPN) Points/Signals Power Voltage to +60 C (no freezing) to +8 C (no freezing) IP0 (EN609) 0 to 0V DC LV (protective very-low voltage: protection class VDE006 / IEC606-- compliant) Removable terminal block: Applicable wire size.mm ( AWG) 0g D rail mounting DC inputs, - and -wire s (PNP) Supplied from AS-Interface line (default: internal switch set to ) Supplied from an external to V DC LV (internal switch set to ) 0mA (provided with overload and short-circuit protection) OFF ma ON ma PNP transistor s (with overload/short-circuit protection) Supplied from external auxiliary power supply U (AUX) External auxiliary power voltage U (AUX) 0.V Current A max. (OUT),.A max. (, OUT), 6A total (Tb 0 C) A max. (OUT), A max. (, OUT), A total (Tb 60 C) Communication Error turns off Profile Slave Type Data Bits D0 D D D A/B slaves IO 0 7 ID A A ID 0 0 OUT OUT PLCs Operator Interfaces Automation Software Power Supplies Sensors USA: IDEC Canada: IDEC 9

6 SXA AS-Interface PLCs Operator Interfaces Specifications LED Indicators Address ModelsSXA-SSN0S0N SXA-SSN0K0N SXA-SSMKSN AS-Interface power: Green LED AUX External auxiliary power U (AUX): Green LED yellow LEDs OUT yellow LEDs Addressing Method Certification Standards Error indication: Red LED ON: Communication error or address 0 Flash: Sensor power supply or is overloaded power supplied from AS-Interface line: Green LED Connect the hand-held programming device (SX9Z-ADRN) to the addressing port on the I/O module using the programming device cable (SX9Z-CN), then the I/O module stops communication through the AS-Interface line. Change slave addresses using the programming device. AS-International Association UL/c-UL, CE Sensors Power Supplies Automation Software 60

7 SXA AS-Interface Internal Circuits SXA-SWN0S0 SXA-SWN0K0N SXA-SWMKSN M connector SXA-SWMKSN AUX AS-i AS-i+ Sensor+ Sensor SXA-SSN0K0N AS-i AS-i+ M connector inputs OUT OUT OUT OUT OUT OUT OUT Connect to protective ground on control panel. Load inputs... I+ I For -wire PNP For -wire PNP Port Power Selector Switch Position U PNP For -wire SXA-SSN0S0N AS-i AS-i+ SXA-SSMKSN AS-i AS-i+ AUX AUX AS-i AS-i+ Sensor+ Sensor + + OUT OUT OUT OUT Connect to protective ground on control panel. I+ I Port Power Selector Switch Position inputs... NPN For -wire inputs... I+ I PNP For -wire s O...O Load U + For -wire Port Power Selector Switch Position U PNP For -wire NPN PNP For -wire Load PLCs Operator Interfaces Automation Software Power Supplies Sensors USA: IDEC Canada: IDEC 6

8 SXA AS-Interface Connector Arrangement SXA-SWN0S0 SXA-SWN0K0N SXA-SWMKSN SXA-SWMKSN PLCs Operator Interfaces OUT ADDR ADDR AUX OUT OUT AUX ADDR Terminal Arrangement Automation Software SXA-SSN0S0N, SXA-SSN0K0N Terminal I- I- I- I- I+ I+ I+ I+ Label (for user) SXA-SSMKSN Terminal I- I- I- I- I+ I+ I+ I+ Label (for user) AUX Power Supplies AS-Interface Terminal ADDR SXA SSN0K0N AS-i+ AS-i Terminal AS-Interface Terminal ADDR OUT SXA SSMKSN AS-i+ AS-i Auxiliary Voltage Terminal Sensors Port Power Selection Power for input ports and connected s can be supplied from either inside (AS-Interface) or outside (external power supply). The selection is done using a switch inside the I/O module. While the input power is supplied from inside, the LED remains on. While the input power is supplied from outside, the LED remains off. I/O statuses are indicated on the front LED indicators. Unlock Press on BOTH sides.. Open Pull upper part until STOP. Switching the input power supply /. Set switch : supply from AS-Interface : external supply 6

9 SXA AS-Interface Dimensions SXA-SWN0S0 SXA-SWN0K0N SXA-SWMKSN Base module is separately ordered SXA-SWMKSN Base module is separately ordered SXA-BFF 8 SXA-SSN0S0N SXA-SSN0K0N SXA-SSMKSN. All dimensions in mm SXA-BFF PLCs Operator Interfaces Automation Software Power Supplies Sensors USA: IDEC Canada: IDEC 6

10 SXA AS-Interface Repeater PLCs SXA-RP No address setting required An AS-Interface network can be extended up to 00 m. IP6 protection Insulation displacement technology allows easy connection to AS-Interface fl at cables. status of AS-Interface and are displayed with LED indicators. The SXA-RP repeater is used to extend the AS-Interface cable. One repeater extends the length of network up to 00 m. A maximum of two repeaters can be used in a network, enabling the construction of a network of up to 00 m. Operator Interfaces Specifications Automation Software Power Supplies Sensors ModelsSXA-RP Voltage 6. to.6v DC Current 60mA (per segment), 0mA (total) Operating Temperature 0 to + C (no freezing) Storage Temperature to +7 C (no freezing) Operating Humidity 0 to 9% RH (no condensation) General Degree of Protection IP6 Insulation Resistance MΩ minimum (00V DC megger) Dielectric Strength 000V AC, minute Applicable Wire AS-Interface fl at cable Weight Approx. 70g Dimensions 60W x 8.H x.d mm Mounting Screw mounting Standard CE LED Indicators (see Dimensions) Indicators Color (when ON) Description AS-Interface Green Power is supplied to line. AS-Interface Green Power is supplied to line. Dimensions Mounting Hole Layout System Setup 60 AS-Interface Master Remote I/O Segment Remote I/O Segment Remote I/O AS-Interface Cable All dimensions in mm. AS-Interface Cable 8. AS-Interface Power Supply 00 m max. Repeater AS-Interface Power Supply 00 m max. 00 m max. Repeater AS-Interface Power Supply 00 m max. 6

11 SXA AS-Interface Address for Communication Terminals Remove the protection cap from the addressing port on the I/O module. Connect the hand-held programming device (SX9Z-ADRN) to the addressing port on the I/O module using the programming device cable (SX9Z-CN), then the I/O module stops communication through the AS-Interface line. Change slave addresses using the programming device. For addressing procedures, see the user s manual for the hand-held programming device. SXA I/O Terminal (IP67) SXA-SWN0S0 SXA-SWN0K0N SXA-SWMKSN SXA-SWMKSN Hand-held programming device SX9Z-ADRN Programming device cable SX9Z-CN Addressing port Addressing port SXA I/O Terminal (IP0) SXA-SSN0S0N SXA-SSN0K0N SXA-SSMKSN Using SwitchNet Addressing Port Adapter on HW To open the addressing port lid, insert a screwdriver into the side slot as shown. Do not lose the lid. Addressing port lid SwitchNet addressing port adapter LA9Z-SNADP Hand-held programming device Attach the addressing port adapter to the programming device cable and insert the addressing port adapter into the addressing port on the communication block. Address for SwitchNet Turn off the power to the SwitchNet control unit and open the lid of the addressing port. Connect the programming device cable (SX9Z-CN) to the hand-held programming device (SX9Z-ADRN) and attach the SwitchNet addressing port adapter (LA9Z-SNADP) to the programming device cable (SX9Z-CN). Insert the addressing port adapter into the addressing port on the SwitchNet control unit. Change slave address using the programming device. For addressing procedures, see the user s manual for the hand-held programming device. After completing address assignment, reattach the lid to the addressing port. SwitchNet HW communication block Hand-held programming device SX9Z-ADRN Programming device cable SX9Z-CN SwitchNet addressing port adapter LA9Z-SNADP SwitchNet L6 communication block Using SwitchNet Addressing Port Adapter on L6 To open the addressing port lid, insert a screwdriver into the right-side hole as shown. The addressing port lid can be removed from the communication block by pulling it out. Addressing port lid SwitchNet addressing port adapter LA9Z-SNADP Attach the addressing port adapter to the programming device cable and insert the addressing port adapter into the addressing port on the communication block. PLCs Operator Interfaces Automation Software Power Supplies Sensors USA: IDEC Canada: IDEC 6

12 SXA AS-Interface PLCs Operator Interfaces Hand-held Programming Device Model SX9Z-ADRN Standards CE Power Supply Powered by built-in battery (recharged using AC adapter) Operation Time 8 hours or 0 read/write operations after full charge Charging Time Approx. hours Operating Temperature 0 to + C Storage Temperature to +8 C (no freezing) Degree of Protection IP0 Weight Approx. 7g Communication Specifications AS-Interface Version. Operation Slave address assignment and data read/write (compatible with the 6-slave mode) Connection Connects to a slave using programming device cable Sensors Power Supplies Automation Software 66

SX5A AS-Interface(Communication Terminal and Repeater)

SX5A AS-Interface(Communication Terminal and Repeater) SXA AS-Interface(Communication Terminal and Repeater) AS-Interface Communication Terminals (Slave Modules) IP67 I/O Module AS-Interface Ver..1 compliant, capable of connecting 6 slaves Compatible with

More information

Automation & Sensing Communication &

Automation & Sensing Communication & Automation & Sensing Communication & Networking AS-Interface Overview... 240 Product Overview... 245 MicroSmart AS-Interface Master Module. 247 SX5A AS-Interface (Communication Terminal and Repeater)...

More information

AS-Interface Safety at Work

AS-Interface Safety at Work Safety Emergency Stop Switches... 478 Operating Instructions... 482 www.idec.com/safety AS-Interface Safety at Work Light Curtains Table of Contents LED Lighting - Pg. 1 Automation & Sensing - Pg. 21 Safety

More information

Communication & Networking

Communication & Networking Automation & Sensing Overview... 232 www.idec.com/communication & Networking OI Touchscreens s Automation Software Supplies Barriers Table of Contents LED Lighting - Pg. 1 Automation & Sensing - Pg. 27

More information

Communication & Networking

Communication & Networking MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators

More information

Communications & Networking

Communications & Networking is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave

More information

Intrinsically Safe Explosion Proof Barriers

Intrinsically Safe Explosion Proof Barriers Safety Intrinsically Safe Explosion Proof For more information on this product family, visit our website. Additional resources include: New and updated product information Downloadable software demos &

More information

Communications & Networking

Communications & Networking 8-Point Source Input & 8-Point Transistor Sink Output odule () Key features include: Communicate with network 8-point source input and 8-point sink output module Removable terminal blocks Use as remote

More information

SA1E: Photoelectric Switches. Polarized Retroreflective Type. Through-beam Type

SA1E: Photoelectric Switches. Polarized Retroreflective Type. Through-beam Type SAE: Photoelectric Simple, compact design for world-wide usage. Key features of the SAE photoelectric sensor include: Four sensing methods Cable types and M8 connector types available NPN output, PNP output,

More information

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches HSA-DMC Magnetic Safety Switches Key features: Compact size and easy positioning. Combination with proprietary relay modules achieves safety category 4 (EN954-1). Compact size ( 16 51mm) Positioning for

More information

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. Switching Power Supplies The offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities. With U 508 isting, additional savings in space and cost can be realized

More information

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45 Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages

More information

Communication & Networking

Communication & Networking SwitchNet HW Series SwitchNet HW Series Control Units 216 Models of 22mm Control Units Contain an AS-Interface Chip AS-Interface Ver. 2.1 compliant, capable of connecting 62 slaves Signals and power are

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12

More information

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number Standard Series Key features: Wide power range: 7.W-24W Universal input : 7.W-W: 8-264V AC/1-37V DC 1W: 8-2V AC/17-264V AC 24-37V DC (selectable) W, W, 24W: 8-264V AC/11-3V DC Overcurrent/overvoltage protection

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete

More information

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide Control Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed

More information

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 40 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Complementary

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication service Web services Discrete

More information

TM241C40U controller M IO transistor NPN

TM241C40U controller M IO transistor NPN Characteristics controller M241 40 IO transistor NPN Main Range of product Product or component type [Us] rated supply voltage 15/12/2018 Modicon M241 Logic controller 24 V DC Discrete input number 24

More information

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W Selection Guide Selection Guide PS5R Slim Line PS5R PS3L Operator Interfaces Communication & Networking PLCs NEW Models Appearance Automation Software Page 107 113 118 Housing Plastic Metal Mounting DIN

More information

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017 Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4

More information

Barriers. Discrete Output Barrier

Barriers. Discrete Output Barrier EB3 EB3 Discrete Output 126 types of pilot lights and buzzers can be connected. Illuminated pushbuttons and illuminated selector switches can be connected by combining with the EB3C discrete input barrier.

More information

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Complementary Topology Main Range of product Product or component type Integrated connection type Bus type Number of slave 0...63 Bus

More information

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category

More information

SYSMAC Remote Transistor Module

SYSMAC Remote Transistor Module 9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

OpenNet Controller. Electrical Specifications. Hardware Features. ONC Capabilities

OpenNet Controller. Electrical Specifications. Hardware Features. ONC Capabilities OpenNet Controller Electrical Specifications FCA-CPK, -CPKM* FCA-CPS, -CPSM* Rated Voltage Maximum Input Current Reverse Polarity Protection Operating Temperature Storage Temperature Relative Humidity

More information

Transistor I/O Link Modules

Transistor I/O Link Modules 9 Transistor I/O Link Modules Reduce Wiring Back to PLC Rack for 32 I/O Points 1 Transmit 16 input signals over just 2 wires (3 wires if only one terminal has a power supply) 1 Normal I/O delay (19.2 ms

More information

Programmable Logic Controllers

Programmable Logic Controllers OpenNet Controller UL Listed File #E Programming Software; WindLDR Programs all IDEC PLCs Windows-based (compatible with Windows,,, NT., ME, XP or Vista) Digital I/O -,, and point cards - inputs and outputs,

More information

Programmable Logic Controllers

Programmable Logic Controllers OpenNet Controller FCA-CPK FCA-CPS OpenNet Controller (with memory card connector) Flash memory card ready Digital I/O -,, and point cards - inputs and outputs, with expansion power supply Analog I/O -

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in 1 Ultra-small Micro Photoelectric PM- SERIES Related Information General terms and conditions... F-17 Glossary of terms / General precautions... P.19~ / P.10 Amplifier Built-in selection guide... P.1~

More information

SmartSlice. System Configuration

SmartSlice. System Configuration SmartSlice The smartest modular I/O system OMRON's SmartSlice I/O system is compact, intelligent and easy. When used with OMRON's CS/CJ DeviceNet or CompoNet master units, no configuration tool is required.

More information

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs 19 Ultra-small Micro Photoelectric Sensor PM- SERIES Related Information General terms and conditions...p.1 Glossary of terms / General precautions...p.98~ / P.98~ Amplifier Built-in Sensor selection guide...p.11~

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Product datasheet Characteristics OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication

More information

Relays & Sockets RR Series Power Relays. Part Number Selection

Relays & Sockets RR Series Power Relays. Part Number Selection RR Series Power Relays Key features: SPDT through PDT, A contacts Midget power type relays Available in pin and blade terminal styles. Options include an indicator, check button for test operations and

More information

Digital Modules AS-i in IP20, 22,5 mm

Digital Modules AS-i in IP20, 22,5 mm Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)

More information

TM241C24T controller M IO transistor PNP

TM241C24T controller M IO transistor PNP Characteristics controller M241 24 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Feb 13, 2018 Modicon M241 Logic controller 24 V DC Discrete input number 14

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage

More information

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

02/11/2015

02/11/2015 DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6... Product datasheet Characteristics OTB1C0DM9LP Complementary Topology Number of slave 63 Bus length Number of devices per segment Discrete input voltage Discrete input voltage type Discrete input type Input

More information

Solid State Remote Power Controller E

Solid State Remote Power Controller E Description The E-T-A is a transistorised switching device providing both protection and signalisation. It is suitable for all applications where the capabilities of the existing PLC s are not sufficient

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet Characteristics controller M241 40 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage 18 Nov, 2018 Modicon M241 Logic controller 24 V DC Discrete input

More information

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit. Selectable safety circuits The light curtain unit has a built-in monitoring function for external devices (such as fused relay monitoring). This supports the construction of light curtain peripheral safety

More information

TM241C40R controller M IO relay

TM241C40R controller M IO relay Characteristics controller M241 40 IO relay Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 100...240 V AC Discrete input number 24

More information

Self-Powered Counters H7EC

Self-Powered Counters H7EC Self-Powered Counters Subminiature Count Totalizers Require No External Power Supply Subminiature 8 x mm (1.89 x.9 in) Improved noise immunity Screw terminal and wire-wrap types available AC, DC, and no-voltage

More information

SmartSlice I/O Plug-and-Play I/O. System Configuration

SmartSlice I/O Plug-and-Play I/O. System Configuration CN CN A/B CN CN A/B RT-ML SW SW RT-ML SW SW RT-@ SmartSlice I/O Plug-and-Play I/O Remote I/O with digital and analogue I/O units, relay outputs and configurable temperature inputs. All SmartSlice units

More information

TWDLMDA20DTK extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state

TWDLMDA20DTK extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state Characteristics extendable PLC base Twido 24 V - 12 I 24 V DC - 8 O solid state Main Range of product Product or component type Discrete I/O number 20 Discrete input number 12 Discrete input logic Discrete

More information

Timers. RTE Series. RTE Series Analog Timers. Specifications. G-8 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC

Timers. RTE Series. RTE Series Analog Timers. Specifications. G-8  USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC Analog Timers Key features of the RTE series include: time ranges and timing functions ON-delay, interval, OFF-delay, one-shot Time delays up to 0 hours Space-saving package (." x." x.0") High repeat accuracy

More information

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE24U controller M IO transistor NPN Ethernet Characteristics controller M241 24 IO transistor NPN Ethernet Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 24 V DC Discrete input

More information

AS-i Safety Output Module, IP20

AS-i Safety Output Module, IP20 a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM241CE24T controller M241 24 IO transistor PNP Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Inrush current

More information

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O ext. in ext. in Safety Output Module with Safety and standard I/O in one module Electronic safety output Additional 3 standard inputs, 1 EDM input, 2 outputs IEC 61508 SIL 3, EN ISO 13849-1 PLe Cat 4,

More information

Safety Control. Safety.

Safety Control. Safety. Selection Guide... 420 Relay HRS-AC... 42 Relay HRS-AF... 424 Relay HRS-DM... 427 Relay HRS-ATE... 429 Relay HR2S-30... 432 Relay HR2S-332N... 437 FSA Multi-function Relay... 443 www.idec.com/safety Control

More information

Safety Control. Safety. Selection Guide Safety Relay HR1S-AC Safety Relay HR1S-AF

Safety Control. Safety.  Selection Guide Safety Relay HR1S-AC Safety Relay HR1S-AF Selection Guide... 394 Relay HRS-AC... 395 Relay HRS-AF... 398 Relay HRS-DM... 40 Relay HRS-ATE... 403 Relay HR2S-30... 406 Relay HR2S-332N... 4 FSA Multi-function Relay... 46 www.idec.com/safety Control

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Product availability : Stock - Normally stocked in distribution facility Price* : 494.00 USD Main Range of product

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Characteristics controller M241 24 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Apr 10, 2018 Modicon M241 Logic controller 24 V DC Discrete input

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Characteristics controller M241 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 100...240 V AC Discrete input number

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital

More information

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours GT3W Key features: Sequential start, sequential interval, on-delay, recycler, and interval ON timing functions 2 time settings in one timer 8 selectable operation modes on each model Mountable in sockets

More information

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input Product datasheet Characteristics TM241C24R Complementary Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Discrete input logic Discrete input voltage Discrete

More information

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS Characteristics battery control module - 24..28.8 V DC - 24 V - 20 A - for regulated SMPS Main Range of product Product or component type Input voltage Output voltage Maximum output current Phaseo Battery

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Product data sheet Characteristics TM241CE40R controller M241 40 IO relay Ethernet Complementary Main Discrete I/O number 40 Discrete input logic Discrete input voltage Discrete input voltage type Voltage

More information

20 General technical data XI/ON

20 General technical data XI/ON 20 General technical data XI/ON General technical information General technical data XI/ON Potential isolation Ambient temperature Operating temperature Storage temperature Relative humidity Noxious gas

More information

Analog Modules AS-i, IP67, M12

Analog Modules AS-i, IP67, M12 Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Characteristics controller M241 24 IO transistor PNP Ethernet Product availability : Stock - Normally stocked in distribution facility Price* : 479.00 USD Main Range of product Product or component type

More information

AS-i 3.0 motor module

AS-i 3.0 motor module 3.0 motor module 3.0 motor module for two 4 V motorized rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) with 4 binary and analog outputs Mixed input/output slave Speed setting of parameter Protection category

More information

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW

8B0C0320HW General information. 2 Order data. 3 Technical data 8B0C0320HW 1 General information Connections for supplying external 24 V devices Extensive protective measures 2 Order data Model number Short description Figure Wall mounting ACOPOSmulti auxiliary supply module,

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input

More information

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC Switching Power Supply DIN-Rail Mount Power Supply With Capacity Up to 240 W for General or Industrial Applications Wide power range: 15 to 240 W 15 W and PFC Models with Universal voltage of 100 to 230

More information

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay

TWDLCDA16DRF compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay Characteristics compact PLC base Twido - 24 V DC supply - 9 I 24 V DC - 7 O relay has not been replaced. Please contact your customer care centre for more information. Discontinued Main Range of product

More information

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Characteristics controller M241 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Apr 10, 2018 Modicon M241 Logic controller 100...240 V AC Discrete input number

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

Diagnostics (Logical) Diagnostics (Physical)

Diagnostics (Logical) Diagnostics (Physical) Enclosure Mounted Input/Output Stations In-Cabinet I/O IP 20 Protection Ideal for Retrofits Automatic Baud Rate Sensing FDN20-4S-4XSG FDN20-4S-4XSG-E* FDN20-4S-4XSG-DIN* * Not UL Electrical Operating Current:

More information

Module 18plus. Description. 18plus

Module 18plus. Description. 18plus Module 8plus Description Wiring of load and signal lines in a space-saving manner will become ever more important for designers of electrical plants and systems, because all control cabinets and control

More information

FS1A Safety Controller

FS1A Safety Controller FS1A ler New (11 logics), introducing 4 new logics! circuit logics compliant international standards ISO 13849-1 PLe International Standard Compliant Cost Saving No Programming Required Compact 24 logics

More information

Terminal block 2 A 5 X 3. Specification

Terminal block 2 A 5 X 3. Specification D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables

More information

TWDLMDA40DUK extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state

TWDLMDA40DUK extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state Characteristics extendable PLC base Twido 24 V - 24 I 24 V DC - 16 O solid state Complementary Input voltage limits Main Commercial Status Range of product Product or component type Discrete I/O number

More information

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable 44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

Barriers. EB3N Discrete Input Barrier with Redundant Output

Barriers. EB3N Discrete Input Barrier with Redundant Output EB3N Discrete Input Barrier with Redundant Output s Build a safety system in an explosive atmosphere. Key features: Safety Performance Performance level e Category 4 [Exia] II C Ensures safety and machine

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information