1 Page 1 Required Reading the Mir MirC Relay Pair series Copyright 2010 National Control Devices, LLC All Rights Reserved. NOTICE: Portions of this Manual REQUIRE Internet Access

2 Page 2 Required Reading Introduction T he MirC Series relay controllers represent a significant Multiple MirC Pairs? advancement in the evolution of the NCD product line. The MirC Series controllers represent a new form of products for our customers who are not electronic engineers but still have Electronic applications they would like to complete. These controllers are the Simplest controllers we have ever developed. They are as easy as wiring up the devices and pushing a button. No programming or configuring is required. However you can extend the functionality of these controllers by using them in conjunction with our Reactor, Key Fob, and Taralist series controllers. In this way MirC controllers can be used to trigger other functions. It may also be triggered by sensory input when used in conjunction with a Reactor or Key Fob controller. The MirC Series are our third line of controllers to offer Autonomous Relay Control (logical control based on inputs without a computer). This new architecture allows remote control of relays without writing a single line of code. The MirC Series are manufactured using Surface Mount Technology. A Break-Away design has been implemented to service the needs of customers who need an enclosure AND to customers who need the smallest possible size. Break Away tabs allow the user to break off the outer edges of the circuit board for a smaller profile. The MirC Series relay controllers represent the future direction of the NCD product line. Who s Qualified to Use the MirC Series? Anyone. The MirC Series Controllers are the most consumer friendly devices we have ever manufactured. Weather you are an electronics engineer or home hobbyist, anyone is qualified to use the MirC Series controller provided this manual is carefully studied. How do the MirC Series Controllers Work? MirC controllers are sold in pairs. Contact closure devices such as buttons and switches attached to inputs on the first controller will trigger relays on the second controller. One Controller is the Sender and the other is the Receiver. The Sender has inputs while the Receiver has relays. When an input on the sender is tripped by a contact closure the corresponding relay on the receiver board is energized. Communication between the Sender and Receiver is Wireless. What Type of Range can Users Expect? There are three range options with the MirC controllers: 300 Feet (Short Range) 1 Mile (Medium Range) 15 Miles (Long Range) These ranges are based on a clear line of sight between MirC controllers/antennas, meaning obstacles such as trees, buildings and walls may limit these ranges slightly. Multiple MirC Controllers can be used in one locations. One Pair of MirC controllers will not interfere with another MirC pair as they are isolated through the way we designed them. MirC Devices are paired together before shipment and will only communicate to each other, for this reason they will not interfere with other MirC controllers. Order of Operations Contact closures are read on one controller, data is sent to other controller wirelessly to turn on or off relays, remote device replies back, busy light flashes to confirm data was received at the other end. Learning Cycle 1) Hardware Reference (getting to know the hardware) 2) Understanding Relay Control 3) Connecting Contact Closure devices to a MirC Sender 4) Controlling Devices with a MirC 5) Troubleshooting a MirC Controller Usage Cycle 1) Attach Power 2) Input Connection 3) External Device connection to Relay 4) Test Range and Functionality in your Environment. Getting Started There is no better place to start than from the beginning. This manual will lead you through the understanding and use of your MirC Series relay controllers in a sequence that will help get you started from the ground up. Please refrain from contacting NCD technical support unless it is absolutely necessary. Most questions will be covered in this manual and NCD technical support staff has been instructed to direct your questions to this manual when appropriate. Please take advantage of the efforts we have invested in building a complete and comprehensive product manual. This will save you time and allow our technical support engineers to focus on product development. Extending Range. Because MirC devices do not interfere with other MirC devices it is possible to link multiple MirC devices in a chain configuration to cover long distances.

3 Page 3 Required Reading There are many versions of the MirC Series relay controllers. It is not practical to photograph and outline every version in this manual. But there are many common elements that are shared among controllers. Most notably, the MirC CPU is identical whether you are using 1-Channel Long Range MirC controllers or 8-Channel Short Range MirC controllers. All MirC controllers share the exact same firmware with absolutely NO differences in firmware revisions. This greatly reduces manufacturing time and troubleshooting while allowing our customers a migration path to different communication range technologies as required. Hardware Reference MirC controllers use different Communication Technologies giving them ranges of 300 Feet (Short Range), 1 Mile, and up to 15 Miles (Long Range)! Power Requirements MirC controllers require a 12VAC or 12VDC power supply to power the logic and relays of the controller. The PWR12 is our stock power supply suitable for use with ALL MirC Series controllers. While it is possible to operate from an automotive 13.8V power supply, higher voltages are not recommended. Additional power filtering may be required for proper operation in automotive electrical systems. The absolute minimum recommended operating voltage is 11VAC or 11VDC. MirC controllers require approximately 100ma for standby and 60ma for each activated relay. Communication Modules may require up to an additional 240 ma, this is documented on the Electrical Specifications Page. Power polarity is not important on the MirC Series controllers. There is no positive and negative terminal. Simply apply power to the controller as it is convenient to make wired connections. The MirC controller will rectify your power supply and attempt to filter noise to safe levels for proper operation. Temperature Requirements Certain components of a MirC controller may run at temperatures exceeding 120 Degrees Fahrenheit. This is normal for a MirC controller and does not indicate a defect. The recommended operating temperature for all MirC controllers is 25 to 80 C. This temperature rating is based on temperature specifications of the components used to build a MirC controller, and is not based on actual testing. We have speculated that MirC controllers may be able to withstand lower temperatures due to the fact that MirC controllers tend to have hot components in critical areas of the design.

4 Page 4 Required Reading Hardware Reference: Anatomy of a MirC Status LEDs indicate which relays are currently active. Inputs on MirC Sender are capable of reading switches, buttons and other contact closure devices such as many motion detectors.. These input serve as the command points for the remote MirC Receiver controller. Beacon/Smart Mode Jumper. Used to switch the controllers from Beacon Mode (good for range testing) to Smart Mode (recommended for day to day function) MirC Controllers are equipped with 1, 2, 4, or 8 Relay Outputs. Relays are simply switches. They DO NOT provide a voltage output, but they will switch the voltage you apply to the relay connections. Please Click Here to see a list of relays and ratings that are commonly supported by the NCD product line (note: not all relays may be supported at this time, relay support will grow as the MirC product line grows). Relays have 2, 3, or 6 connections per relay depending on configuration. SPST, SPDT, and DPDT relays will be supported. Please see the following article for a detailed explanation of these relay types. The BUSY/READY LEDs indicate CPU activity. Flashing Busy LED signifies VALID data has been received from the Remote MirC controller. If busy light never flashes check remote device and range abilities of devices. SPST Relay SPDT Relay DPDT Relay MirC Controllers include a 2.1mm Barrel Connector AND a 2-Position Screw Terminal. Use either connector to provide 12V power to the MirC Controller. MirC controllers are compatible with 12V AC or DC power supplies with a actual voltage output of 11 to 13.8V. Polarity is corrected by the MirC controller, therefore a Positive and Negative terminal are NOT labeled on the board (it is not possible to connect power backwards to MirC controllers, the MirC controllers will automatically correct polarity).

5 Page 5 Required Reading Hardware Reference: Understanding Inputs Beacon/Smart Mode Jumper The Beacon/Smart Mode Jumper is used to change the way communications is handled by the MirC controllers. Inputs are capable of reading Contact Closure generating devices such as buttons and switches. A wire connected from the ground terminal to the input terminal would trigger the input, as this would be considered a contact closure. MirC Inputs play a vital role in the use of a MirC controller. Before we begin using the controller, it is essential that users understand the role of these inputs. Improper use of these inputs can cause Irreparable Damage to the MirC controller, so a firm understanding of these inputs is critical to the longevity of the controller. Users must NEVER apply any voltage to an input on the MirC Sender controller, these inputs are for Contact Closure connection only. A MirC Sender controller has as many inputs as its mating MirC Reciever has Relays. So a pair of 4 relay MirC controllers will have 4 relays on the Receiver board and 4 inputs on the Sender board which are used for controlling the relays on the Reciever board, the same holds true for 1, 2, and 8 relay versions. Beacon Mode In Beacon Mode communication is nearly constant which makes it a good choice for range testing. A controller can be placed in one location and the other MirC controller can be carried to other locations to test range. The busy Light flashes constantly if there is good communication between the two MirC controllers. If communication is lost in Beacon mode relays will remain in their current state and will not automatically turn off. If the busy light stops flashing the devices are out of range of each other and the distance should be shortened. While Beacon Mode is very good for range testing it does lengthen the amount of time it takes for an input on the Sender board to trigger a relay on the Reciever board. Beacon mode is not recommended for day to day use. Smart Mode In Smart mode communication is not as constant as in Beacon Mode, however Smart Mode does still check for communication with remote device periodically. For this reason inputs on the Sender MirC controller can trigger Relays on the Reciever MirC controller very fast because input changes are immediately sent to the remote device. If communication is lost in Smart mode for 10 to 15 seconds all relays will go off and communication streams will accelerate to attempt immediate recovery. If this happens check remote device and range abilities of your MirC controllers. Smart mode also consumes less power than Beacon mode, this along with fast relay triggering is why we recommend Smart mode for every day use. Regardless of the Mode you choose, if the busy LED flashes the two devices are communicating properly. If the Busy LED does not flash at all the devices are unable to communicate. Beacon Mode: Constant Communication. Good for range testing. Relays will not switch off if communication is lost. Higher power consumption. Relay Status will update slower to input changes on remote board. Smart Mode: Fewer Communications between Devices Relays will switch off if Communication is lost. Lower Power consumption than Beacon Mode. Relay status Updates very fast to input changes on remote Board.

6 Page 6 Required Reading Hardware Reference: Understanding Relays On the previous page, we introduced you the MirC Inputs and how Contact Closures play a key role in triggering Relays on the Remote MirC board. In this Section we will continue our focus on the Hardware portion of the MirC controller, which brings us to our next topic: Understanding how the Relays work. MirC Controllers have 1, 2, 4, or 8 Relays integrated into the circuit board. A relay is similar to a switch. The only difference between a switch and a relay is the actual mechanism for changing the on/off status of the switch. On a switch, you manually push on a piece of metal or plastic to operate the switch. On a relay, an electric current is used to operate the switch. Though a relay resembles the characteristics of a switch, it cannot be controlled by touching it with your finger. So from now on, we will use the word Relay to indicate a switch that is controlled by the MirC controllers (instead of your finger). Controlling Relays There is only one way to control the relays on MirC Series controllers. Relays are triggered by inputs on the opposite board. They may not be triggered in any other way. Relay Logic may be used to complete more complex tasks. Please refer to our page on Relay Logic. Relays do NOT provide a voltage output. They provide a contact closure output, exactly like the terminals found on a light switch at your local hardware store. Wiring to a relay will be slightly different depending on the model of MirC controllers you choose. Some relays, such as the 5A and 10A versions have screw terminals that can accept 12 Gauge or smaller wire. Other versions such as the 20A and 30A relays have a.250 Quick Connect terminal (the appropriate mating connector can be found at any hardware or automotive supply store). Again, relays do not provide a voltage output. They ONLY switch whatever voltage you supply into the relay. Relays are available in SPST, SPDT, and DPDT configurations. In addition, both Mechanical and Solid State relays will be supported by the MirC series controllers. If you are unfamiliar with the different versions of relays available, you can review the following article, which explains these relay types in great detail. The above article will help you determine the best type of relay for your application, showing you the formulas for calculating relays sizes that are appropriate for your application. If you intend to use the MirC series relay controllers for inductive applications, the following article MUST be reviewed. An example of an inductive application is any device that involves motion. For instance, using a MirC Controller to control a motor, a solenoid, or a valve. Other types of inductive applications include anything with a transformer such as a fluorescent light or a power transformer of any kind. Logic circuits (including those found on the MirC Controller) may malfunction in sever conditions. The above article will show you how to safely implement these kinds of loads which greatly reduces the chances of a malfunction. Some inductive applications generate excessive noise, and may not be suitable for use with the MirC Series Relay controllers. Solid State MirC Relay Controllers Should be considered for these high-noise applications.

7 Page 7 Required Reading Hardware Reference: Break-Away Tabs Physically, most MirC controllers are actually 2 sizes. When you receive your MirC, the unusual shape and size ensures the MirC can fit into a standard enclosure. Optionally, you can make the controller smaller by breaking away the outer tabs. Break-Away tabs are useful in applications where space may be a concern. This allows your MirC to offer the same functionality in the smallest possible profile. Break-Away tabs are unique to the NCD product line and are a standard option for most devices released in 2010 and later. Before breaking the tabs on your controller, please be advised that your MirC controller will not be returnable for refund or credit if the Break-Away Tabs have been removed. To break away the tabs, gently but firmly grab each break-away tab with a pair of pliers and bend the tab back and forth until it breaks away from the main circuit board. This will NOT damage the controller in any way. Breaking the Tabs from a controller DOES NOT VOID the 5- Year Warranty. Please see the NCD return policy if you would like more information on the policies that apply to Surface Mount devices. MirCR25 Shown Above as shipped from National Control Devices. The unusual shape accommodates a standard enclosure. Bend the tabs to break them away from the board. Note that controllers with Broken Tabs are NOT Returnable for Refund or Credit, but are still covered under our 5-Year Limited Warranty. Shown above, the final controller with tabs removed is physically

8 Page 8 Recommended Reading This is why we recommend using MirC controllers with more relays than you may actually need Using Relays to Create Logical Conditions The MirC Series Relay Controllers offer a great balance of flexibility and easy configuration. However, complex decision making is sometimes outside the scope of a MirC controller. Relay Logic demonstrates easy ways to hard-wire your decisions using a MirC Controller. Sample 1 This sample demonstrates how a relay can be used to activate a light bulb. When the relay turns on, the light comes on. Only one power wire is switched with this sample using the COM (common) and NO (normally open) connections of a relay. Sample 2 This sample demonstrates how a relay can be used to turn a light bulb OFF. When the relay turns off, the light will be ON. Only one power wire is switched in this sample using the COM (common) and NC (normally closed) connections of a relay. Sample 3 The sample Above demonstrates how two activated relays are required to activate a light bulb. This is the same as a Logic AND function because Relay 1 AND Relay 2 MUST be on to activate the light. Relay Logic Sample 5 This sample demonstrates the AND/OR function. The Light Bulb will be activated if Relay 1 AND Relay 2 are ON OR if Relay 3 is ON. This sample is perfect for applications that may require a Logical condition of 2 relays PLUS an Override feature. For instance: Relay 1 is a Night/Day Sensor, Relay 2 is a Moisture Sensor. If its Dark AND the soil is Dry, Relays 1 and 2 can activate a Pump. Sample 6 This sample demonstrates how either relay can be used to activate a light. In this sample, only one activated relay is required to activate the light. If both relays are activated, the light will be on. Sample 7 This sample demonstrates how a 3-way light switch can be used to activate a light. A 3-way light switch is often found in your house where two light switches can be used to activate a single light. This sample is exactly the same as a 3-way light switch, the only difference being each physical switch is replaced by a relay. Operationally, it works the same way. Each relay activation will cause the light to toggle. Switching two relays at one time is like flipping 2 switches at once...with the same result. This sample is particularly useful since you can replace one relay (as shown in the diagram) with a physical light switch. This will allow a computer/mirc to control a light as well as manual operation of a light. Properly used, this can be one of the most valuable diagrams we offer on this page. Sample 8 This sample demonstrates how to control the direction of a DC motor using 2 relays. Braking is accomplished by connecting both motor terminals to a common power connection (Faraday's Law). The capacitors shown may not be required for small motors, but if you experience problems with relays shutting themselves off, the induction suppression capacitor will be required. The.1uF capacitor helps suppress electronic noise if the battery were to be used by sensitive devices (such as radios/amplifiers). Sample 4 The sample above demonstrates how three activated lights are required to activate a light bulb. This is the same as a Logic AND function because Relay 1 AND Relay 2 AND Relay 3 MUST be on to activate the light.

9 Page 9 Recommended Reading Electrical Specifications All Controllers Require 12 Volt Dc Power Source. MirC Part # Min/Max. Current Consumption: Controller 300 Ft Range 1 Mile Range Long Range MirCR15/R110 80ma-115ma 95ma-118ma 150ma-180ma MirCR25/R210 80ma-140ma 95ma-145ma 150ma-195ma MirCR45/R410 80ma-200ma 95ma-205ma 150ma-250ma MirCR85/R810 80ma-370ma 95ma-380ma 150ma-430ma MirCR8120/R130 80ma-150ma 95ma-155ma 150ma-220ma MirCR220/R230 80ma-220ma 95ma-225ma 150ma-275ma MirCR420/R430 80ma-385ma 95ma-390ma 150ma-450ma MirCR820/R830 80ma-680ma 95ma-685ma 150ma-720ma MirCSSR8x 80ma-390ma 95ma-395ma 150ma-445ma Minimum Current consumption based on all relays off/max consumption based on all relays on. Amperage consumption may fluctuate as much as 10 % Note: Long Range Modules may fluctuate in power consumption significantly from 80ma up to 150ma in all relays off mode. Maximum Rated Minimum Temperature Ratings (Estimated)** -25 C 80 C Mechanical Relay Cycle Life (Non-DPDT Versions): Mechanical Relay Cycle Life (DPDT Versions): >10,000,000 Cycles >2,000,000 Cycles Typical Operational Cycles per Minute 1,800 Relay Activation Time: >5ms <15ms Relay Deactivation Time: >5ms <20ms Command Processing Time: 1ms 3ms 5ms Relay Electrical Limits should be Determined by Reviewing Appropriate Relay Data Sheet: 5A Relays Data Sheet 10A Relays Data Sheet 20A Relays Data Sheet 30A Relays Data Sheet Solid State Relays Sheet ** Ratings Based on Data Sheets of Component Used, Actual Tolerance May Exceed Ratings.

10 Page 10 Recommended Reading Problem: Busy LED is not Periodically Flashing/Remote Device is not responding. The Busy LED Signifies Successful communication with remote device. If the Busy LED is not flashing the MirC in unable to communicate with the Remote Device. Possible Problems could be lack of sufficient power source at remote location, remote device is out of range, humidity can affect overall communication range (Dryer environments tend to have shorter ranges than wetter ones), damaged controller can prevent busy LED from flashing, if power is applied to inputs this will damage the controller. Solution: Check Power source for both Devices. Place antennas or devices as high physically as possible. If Humidity seems to be causing Spotty Reception contact us for a better antenna option. If device seems to be damaged check to make sure you have NEVER attached voltage of any kind to the controllers inputs. Troubleshooting Problem: Controller is Running HOT Solution: It is normal for some components run very hot on the MirC series relay controllers. This is not a concern as we have tested the design carefully and are operating our components well within the specified limits of the components we are using. It is NOT normal for the CPU to run hot at any time. The CPU should remain cool. If the CPU is running hot the CPU has been damaged. Problem: Relays turn off unexpectedly: This can happen if the devices loose communication with each other in smart mode. It can also happen when Inductive loads are attached to the relays (See page 6 Understanding Relays). Solution: Shorten the distance between controllers. Carefully review the necessary steps for suppressing Induction in this Article. Be sure to also check your power source. Known Bugs: At this time, the MirC Series Relay Controllers are not known to have any bugs in the firmware. There were 50 internal versions developed and tested over a span of 9 months to arrive at a Version 1.0 Firmware Release. If you experience a bug, please us so we can examine the problem in more detail. Any known bugs will be posted in this section of the manual.

11 Page 11 Required Reading How They Work Ethernet Mirror Setup Advanced Setup All Ethernet Mirror Modules work in pairs. Triggering the contact closure input on one board will turn on the relays on the remote board. The local relay status and remote relay status will be indicated on the board through LEDs. The Ethernet Mirror Modules will work on a local area network as well as across internet. There are redundant communication channels between the two boards, as long as one of them is able to make connection, the boards will work. Jumper Settings Beacon Mode When the jumper is set to beacon mode, relays will not change status when connection is lost. Smart Mode When the jumper is set to smart mode, all relays will turn off when connection is lost. Connection Equipment Required A Router A computer connected on the router. Two mirror modules connected to the same router. Steps Connect the two Mirror modules that need to be paired to the Lan. Run ConfigureUtility.exe on computer connected to the same Lan. Select one module and click the Edit button. Input the server address and port number. The default port is Both modules need to be edited. Input if there is no server. For example, if only one server is used, input for the rest of the servers. The remote mac address can be setup in the next steps. Select the two modules in the list and click Pair Once the two modules are paired, there will be a connected symbol showed in front of the items. Connect directly When two modules are in the same local area network, they can communicate to each other directly without a Mirror Server. No Internet connection is required. Connection through Mirror Server When two mirror modules are located in different networks, they can talk to each other through the NCD Mirror Server. Mirror modules can connect to up to four servers at the same time. As long as one of the servers can be connected to, the mirror modules will work. The server can be setup inside a local area network as long as both modules are able to access it. Setup Quick Setup Equipment Required. A Router A computer connected on the router. Two mirror modules connected to the same router. Steps: Connect the two Mirror modules that need to be paired to the LAN. Run ConfigureUtility.exe on computer connected to the same LAN. Select the two modules which appear in the list and click Pair Once the two modules are paired, there will be a connected symbol in front of the items. The pair setup with servers can work through internet. It is not necessary to be in same local network. Tips Set the Remote Mac Address same as Local mac address. This can be used to test the device connection with the server. When the remote address is the same as the local address, it will loop back when an input is triggered, triggering a relay on the same board. The two modules can communicate with each other directly over a LAN through this quick setup.

12 Page 12 Required Reading Ethernet Mirror Setup Continued ConfigureUtility.exe The ConfigureUtility is used to configure the mirror modules. This program can list all available modules in the same local area network. There is a connection symbol for paired devices. Steps to pair devices. Select device and click Edit button, setup servers. Both devices have to be setup. Select both devices in list and click the Pair button. The connected symbols should show in front of the item once they are paired. For each pair, one of the devices will be the master device. The other one will be the slave device.

13 Page 13 Required Reading Ethernet Mirror Setup Continued Mirror Server Mirror Server is a program that forwards messages between matched devices. Setup Mirror Server on Microsoft Windows platform. The Mirror Server can run as a windows console program or run as a windows service. Run Mirror Server as a console program Quick Setup Double click the MirrorServer.exe. A console window will be opened. Note: Firewall setting. The MirrorServer will listen on port The port has to be opened in windows Firewall setting. Or add this MirrorServer.exe to exception in Firewall. Run Mirror Server as a service Run ServerManager.exe Run Mirror Server as a service Run ServerManager.exe The service needs to be installed first. Click Install Mirror Server Service this will install the service to the computer. Click Start button to start the service. The Server Manager needs to be run as Administrator. Firewall setting is required to run this program. NCDMirrorServerSvr.exe needs to be added to exception of the Windows firewall. Suggestion: It is strongly suggested to run console version server first to make sure everything is working before running as a service. The advantage of running as a service is that the program will run in background and will be started automatically when the windows starts. It is possible to setup a mirror server in other platforms other than Microsoft Windows. There is a mirror server written in Ruby. This program can run on all platforms that have Ruby installed. The Ruby version is supported in Windows, Linux, and Mac OS. It can be downloaded here. The version we are using is To start the Mirror Server, type ruby /pathtomirrorserver/mirrorserver.rb

NATIONAL CONTROL DEVICES MirX Wireless Quick Start Guide

NATIONAL CONTROL DEVICES MirX Wireless Quick Start Guide NATIONAL CONTROL DEVICES MirX Wireless Quick Start Guide Relay Pair Series-Wireless N A T I O N A L C O N T R O L D E V I C E S MirX Relay Pair Series-Wireless National Control Devices, LLC PO Box 455

More information

NATIONAL CONTROL DEVICES Push Notification - Serial Quick Start Guide

NATIONAL CONTROL DEVICES Push Notification - Serial Quick Start Guide NATIONAL CONTROL DEVICES Push Notification - Serial Quick Start Guide N A T I O N A L C O N T R O L D E V I C E S Push Notification - Serial Quick Start Guide National Control Devices, LLC PO Box 455 Osceola,

More information

NATIONAL CONTROL DEVICES Reactor Relay Series Quick Start Guide

NATIONAL CONTROL DEVICES Reactor Relay Series Quick Start Guide NATIONAL CONTROL DEVICES Reactor Relay Series Quick Start Guide Autonomous Relay Controllers N A T I O N A L C O N T R O L D E V I C E S Reactor Relay Series Autonomous Relay Controllers National Control

More information

NATIONAL CONTROL DEVICES NCD Hardware Reference Quick Start Guide

NATIONAL CONTROL DEVICES NCD Hardware Reference Quick Start Guide NATIONAL CONTROL DEVICES NCD Hardware Reference Quick Start Guide N A T I O N A L C O N T R O L D E V I C E S NCD Hardware Reference National Control Devices, LLC PO Box 455 Osceola, MO 64776 Phone 417.646.5644

More information

NATIONAL CONTROL DEVICES Push Notification - WiFi Quick Start Guide

NATIONAL CONTROL DEVICES Push Notification - WiFi Quick Start Guide NATIONAL CONTROL DEVICES Push Notification - WiFi Quick Start Guide N A T I O N A L C O N T R O L D E V I C E S Push Notification WiFi Quick Start Guide National Control Devices, LLC PO Box 455 Osceola,

More information

Quick Start Guide. ZR1x/ZR2x. Wireless Single / Dual Relay Controllers. Copyright 2012 National Control Devices. All Rights Reserved.

Quick Start Guide. ZR1x/ZR2x. Wireless Single / Dual Relay Controllers. Copyright 2012 National Control Devices. All Rights Reserved. Quick Start Guide ZR1x/ZR2x Wireless Single / Dual Relay Controllers Copyright 2012 National Control Devices All Rights Reserved. NOTICE: Portions of this Manual REQUIRE Internet Access Page 2 Quick Start

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Abstract. GLV User Manual 1

Abstract. GLV User Manual 1 GLV User Manual 1 Abstract This user manual is a high level document that explains all operational procedures and techniques needed to operate the GLV system in a safe and effective manner. Anyone operating

More information

SS2200 Remote Controller

SS2200 Remote Controller SS2200 Remote Controller General Purpose, DC Voltage General The SS2200 Remote Controller is a microprocessor-based programmable controller specifically designed to control single line and dual line centralized

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Safety Control Relay Product Catalog

Safety Control Relay Product Catalog Product Catalog Wall Mount for use with Safety Mats Safety Edges Safety Bumpers Safety Sensors 2 wire Safety Sensors 4 wire DIN Rail Mount Intrinsically Safe Explosion Proof Wall Mount Introduction The

More information

Wiring Instructions v4

Wiring Instructions v4 Wiring Instructions v4 GateKeeper h4.2 Technical Support support@gymmastersoftware.com USA: 415 678 1270 Australia: 03 9111 0323 : 03 974 9169 Copyright 2018 Treshna Enterprises. All rights reserved. 15

More information

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14) (Part # S-VIA-CM14) The 12-Bit 0-5 Volt Input Adapter is used for measuring voltage levels and is designed to work with the HOBO Weather Station and Micro Station data loggers. The input adapter also provides

More information

NATIONAL CONTROL DEVICES Fusion ProXR Advanced Quick Start Guide

NATIONAL CONTROL DEVICES Fusion ProXR Advanced Quick Start Guide NATIONAL CONTROL DEVICES Fusion ProXR Advanced Quick Start Guide Fusion Relay Control Command Set N A T I O N A L C O N T R O L D E V I C E S ProXR Advanced Fusion Relay Control Command Set National Control

More information

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart.

Press the PEN HOME key to move the pen(s) to the outside of the chart. The pen(s) is automatically raised off the chart. DICKSON GETTING STARTED 7-day chart rotation 0 to 100 o F KT8P0/2/3 & KT856 Remote Sensing Temperature Recorder QUICK START 1. Remove the protective pen cap(s). 2. Connect Probe(s): a. KT8P0/2/3: Make

More information

CDD Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner

INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner INSTALLATION AND MAINTENANCE INSTRUCTIONS For Chemline A- & Q-Series Actuator with Digital (AC) Positioner General: The Digital High-performance position AC Controller is designed to control quarter-turn

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR-

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series One Door TCP/IP Web Server Controller. Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR- QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series One Door TCP/IP Web Server Controller Model: ACP-DXEL1 to ExitPushAccessAccessBoard PWR- Table of Contents 3 01- Introduction 4 02 - Overview 4 02.1

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

SMS Commander Manual

SMS Commander Manual SMS Commander Manual For the GB0101S V1.2 Before Attempting to connect or operate this product, please read these instructions in its entirety, especially the guarantee conditions. TABLE OF CONTENTS Introduction...3

More information

This is an inspection failure, not meeting the requirement of >10k Ohm between either PD battery post and chassis.

This is an inspection failure, not meeting the requirement of >10k Ohm between either PD battery post and chassis. Troubleshooting This is a document put together by CSA Laura Rhodes that contains a lot of information about troubleshooting steps for a lot of common control system problems encountered at events. No

More information

Girard Awnings R ACMC Motor Controller (Last revised on May 10, 2008) A Visionary Awning Control by

Girard Awnings R ACMC Motor Controller (Last revised on May 10, 2008) A Visionary Awning Control by Girard Awnings R ACMC Motor Controller (Last revised on May 10, 2008) R A Visionary Awning Control by Girard AC Motor Controller Installation Guide ACMC Revision 2.08 May 10, July 2008 ACMC Installation

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

Installation and Configuration Quick Guide

Installation and Configuration Quick Guide Installation and Configuration Quick Guide R2000--Industrial Cellular VPN Router This document is written for the user which in order to let the user more easily install the router and also know the way

More information

CDD4 Series Room CO2 Transmitter Installation Instructions

CDD4 Series Room CO2 Transmitter Installation Instructions CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include

More information

NATIONAL CONTROL DEVICES. KFX Series Quick Start Guide

NATIONAL CONTROL DEVICES. KFX Series Quick Start Guide NATIONAL CONTROL DEVICES KFX Series Quick Start Guide NATIONAL CONTROL DEVICES NATIONAL CONTROL DEVICES KFX Series Quick Start Guide National Control Devices, LLC PO Box 455 Osceola, MO 64776 Phone 417.646.5644

More information

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism. Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism. The PIEXX IMP-22G2, H allows you to put your slave clock back into

More information

Sync Control. Installation/Operation Manual Rev. E

Sync Control. Installation/Operation Manual Rev. E 9 315 Sync Control Installation/Operation Manual 164201140 Rev. E ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

-----other notes This picture was taken from here:

-----other notes This picture was taken from here: This is an introduction to programmable logic controllers - PLCs for short. Here is a picture of a simple one. A programmable logic controller is unit of hardware used to control and automate an industrial

More information

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016 Operating Instructions Power Supply & Latching Relay For Switches Model: RL-6000 manual_rl-6000_1016 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

ADVANCED MICRO SYSTEMS

ADVANCED MICRO SYSTEMS Overview... 3 Included in the Box:... 3 Pinout... 4 Installation... 5 Power Supply... 6 Stepping Motors... 7 DIP Switch (JP1) Location... 8 Setting the Output Current (JP1)... 8 Microstep Resolution (JP1)...

More information

NATIONAL CONTROL DEVICES ProXR Enhanced Quick Start Guide

NATIONAL CONTROL DEVICES ProXR Enhanced Quick Start Guide NATIONAL CONTROL DEVICES ProXR Enhanced Quick Start Guide Relay Control Command Set NATIONAL CONTROL DEVICES ProXR Enhanced Relay Control Command Set National Control Devices, LLC PO Box 455 Osceola, MO

More information

Installation Instructions

Installation Instructions LUCCI Slim Line Fan Remote Control SKU# 210012 Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF

More information

NATIONAL CONTROL DEVICES Fusion Essentials Quick Start Guide

NATIONAL CONTROL DEVICES Fusion Essentials Quick Start Guide NATIONAL CONTROL DEVICES Fusion Essentials Quick Start Guide N A T I O N A L C O N T R O L D E V I C E S Fusion Essentials Quick Start Guide National Control Devices, LLC PO Box 455 Osceola, MO 64776 Phone

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 3YEAR WARRANTY & LIMITATION OF LIABILITY TRI-TRONICS COMPANY, INC. warrants that the products delivered by it will be of the kind and quality described in the order or contract

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

gridcomm GC1310 Master Light Controller Hardware Installation Guide

gridcomm GC1310 Master Light Controller Hardware Installation Guide gridcomm GC1310 Master Light Controller Hardware Installation Guide GC1310 GC1318 Non LoRA option LoRA option GridComm Pte. Ltd. Page 1 of 16 GC-Net and the gridcomm logo are trademarks of gridcomm Pte

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

6222 Two Door Module Technical Operations Manual

6222 Two Door Module Technical Operations Manual 6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5

More information

Wiring Instructions v3

Wiring Instructions v3 Wiring Instructions v3 Gatekeeper h4.1 Technical Support support@gymmastersoftware.com USA: 415 678 1270 Australia: 03 9111 0323 : 03 974 9169 Copyright 2017 Treshna Enterprises. All rights reserved. Table

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

SMART SHOT CONTROLLER FLUID USERS GUIDE

SMART SHOT CONTROLLER FLUID USERS GUIDE SMART SHOT CONTROLLER FLUID USERS GUIDE Pg. 2 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER FEATURES 3 SMART SHOT CONTROLLER CONFIGURATIONS 4 FLOAT/SENSOR WIRING 5 TOP AND BOTTOM FLOAT/SENSOR

More information

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K) CRM Applications CRM includes a control relay box and a power supply; additional

More information

Software... pg3 File Maintenance Training

Software... pg3 File Maintenance Training V-MUX Installation Practices March 2010 1 V-MUX Installation Practices Software...... pg3 File Maintenance Training Electrical...... pg3 Circuit breakers or Fuse protection 3 Power to Nodes 3 Ground to

More information

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1 BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,

More information

Casambi CBU-ASD. Bluetooth 4.0 Wireless Control Unit for LED Drivers. Features. 1 Description

Casambi CBU-ASD. Bluetooth 4.0 Wireless Control Unit for LED Drivers. Features. 1 Description Casambi CBU-ASD Bluetooth 4.0 Wireless Control Unit for LED Drivers Features Wirelessly controllable with a smart device. No need for an external gateway device. Forms automatically a fast wireless mesh

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

ZC Series Zone Monitoring Controllers

ZC Series Zone Monitoring Controllers ZC Series Zone Monitoring Controllers Installation Instructions MANUAL Reset Controllers Model Description Part Number ZC-1 1 Zone Controller 0421 ZC-2 2 Zone Controller 0422 ZC-3 3 Zone Controller 0423

More information

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location... DRV7 USERS GUIDE Overview... 3 Included in the Box:... 4 Pinout... 4 Installation... 5 Power Supply... 6 Stepping Motors... 8 DIP Switch (JP1) Location... 9 Setting the Output Current (JP1)... 9 Microstep

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español

More information

User Manual. Solar Inverter for Water Pump

User Manual. Solar Inverter for Water Pump User Manual Solar Inverter for Water Pump SP Revival Series Version: 1.2 Table Of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 Inspection... 1 Installation... 1 Operation...

More information

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating

Smart heating system. with wireless thermostats & smartphone control for every room. Get the most out of any water based underfloor heating Smart heating system with wireless thermostats & smartphone control for every room Get the most out of any water based underfloor heating DETAILED OVERVIEW Control the heating in your home from anywhere.

More information

Instruction Manual HPH-8

Instruction Manual HPH-8 Specifications HPH-8 Trigger cable 120-volt, Nema 1-15 Main Power 50-amps @ 240-volt AC Power receptacles (4) Nema 5-15 or 6-15 Maximum HID wattage 8000 watts (on 240-volt) 4800 watts (on 120-volt) Maximum

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

G540 User Manual. Date Modified: March 5, 2012 Page 1 of 10

G540 User Manual. Date Modified: March 5, 2012 Page 1 of 10 G540 User Manual Date Modified: March 5, 2012 Page 1 of 10 DIMENSIONS PHYSICAL AND ELECTRICAL RATINGS Minimum Maximum Units Supply Voltage 18 50 VDC Motor Current 0 3.5 A Power Dissipation 1 13 W Short

More information

MT400 MOTION CONTROLLER

MT400 MOTION CONTROLLER MT400 MOTION CONTROLLER INSTALLATION & TECHNICAL MANUAL 5/30/2012 417 Wards Corner Road Loveland, OH 45140 800.659.8250 FAX: 513.398.2536 www.maxitronic.com Table of Contents Page 3: Page 4: Page 5: Page

More information

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc.

Power Over Fiber USER GUIDE. SYSTEM INSTALLATION INFORMATION Description. The leader in rugged fiber optic technology. RLH Industries, Inc. USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-145 2018A-0119 Power Over Fiber SYSTEM INSTALLATI INFORMATI Description Our patented Power Over Fiber (PoF) system provides

More information

Relay Contact Output Modules

Relay Contact Output Modules Relay contact output modules offer dry circuits, that is, circuits without leakage current. Leakage currents are present on solid-state outputs; these currents are capable of energizing highly sensitive

More information

MINI-MAX WIRELESS. RECEIVER WIRING WHITE...to...TERMINAL #1

MINI-MAX WIRELESS. RECEIVER WIRING WHITE...to...TERMINAL #1 MINI-MAX INSTALLATION THIS MANUAL IS DESIGNED TO LEAD YOU STEP BY STEP THROUGH THE PROCEDURES REQUIRED TO TEST, INSTALL AND USE YOUR MINI-MAX. BY FOLLOWING THESE PROCEDURES AND SETTING UP THE SYSTEM CORRECTLY

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS Installation Manual 1180 METRIX Experience Value 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1-281-940-1802 After Hours Technical Assistance: 1-713-702-8805

More information

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Hardware User s Manual. Digital Video Motion Detector DVMD1-X Hardware User s Manual Digital Video Motion Detector DVMD1-X Version 010 Revision A July, 2004 2395 Kenwood Drive Boulder, CO 80303 (303) 543-0440 TECHNICAL SPECIFICATIONS VENDOR Radiant Inc. http://www.dvmd.com

More information

Contents. Please read and remember the following warnings before using the RELAYplate:

Contents. Please read and remember the following warnings before using the RELAYplate: Contents 1 Warnings o 1.1 What is a Relay? o 1.2 Basic Features of the RELAYplate o 1.3 Attaching a Load to the RELAYplate o 1.4 The RELAYplate Command Set 1.4.1 RELAY Control Functions 1.4.2 LED Control

More information

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information

Tempco Instruction Manual

Tempco Instruction Manual Tempco Instruction Manual 1/16 DIN Solid State Temperature Controller Relay Output Solid State Output For Heating Model Numbers: TEC-901, TEC-902, TEC-905 Temperature controls in this series are designed

More information

DUAL SWITCH CONTROLLER

DUAL SWITCH CONTROLLER DUAL SWITCH CONTROLLER INSTRUCTION MANUAL IMPORTANT: If the Dual Switch Controller is to be used with a Dielectric 50000 Series Switch, control cable P/N 1100007364 or 11000007365 must be used. See Section

More information

zeus studio bus 1) Introduction: The Advantages of ZEUS 2) Understanding power consumption of your modules and the system

zeus studio bus 1) Introduction: The Advantages of ZEUS 2) Understanding power consumption of your modules and the system 1.1 1) Introduction: The Advantages of 2) Understanding power consumption of your modules and the system 3) Attaching the Zeus Studio Bus to the case 4) List of recommended parts and part numbers (power

More information

Ocean Controls KTA-224 Modbus IO Module

Ocean Controls KTA-224 Modbus IO Module Ocean Controls Ocean Controls 8 Relay outputs (5A, 250VAC contacts) 4 Opto-Isolated Inputs with counters 3 Analog Inputs (10 bit) jumperselectable for 0-5V or 0-20mA 4 Input Counters RS485 or USB (virtual

More information

Suprex RS-485 SPX-7500 Wired Reader-Extender

Suprex RS-485 SPX-7500 Wired Reader-Extender Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

Touch Sense Controller

Touch Sense Controller Touch Sense Controller Paul Boston May 11, 2011 (Modified May 22, 2014) (Modified Dec 28, 2015) The Touch Sense Controller is a microprocessor-controlled circuit designed to provide a switch closure when

More information

NATIONAL CONTROL DEVICES Fusion Reactor Quick Start Guide

NATIONAL CONTROL DEVICES Fusion Reactor Quick Start Guide NATIONAL CONTROL DEVICES Fusion Reactor Quick Start Guide N A T I O N A L C O N T R O L D E V I C E S Fusion Reactor Quick Start Guide National Control Devices, LLC PO Box 455 Osceola, MO 64776 Phone 417.646.5644

More information

JVA SMS Gateway User Manual

JVA SMS Gateway User Manual www.jva-fence.com.au JVA SMS Gateway User Manual PTE0319 JVA SMS Gateway User Manual Introduction The PTE0319 JVA SMS Gateway enables a group of JVA Z Series energisers to be controlled and monitored by

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION The DFI 7000 Signal Conditioner-Indicator is a complete 4-1/2-digit signal conditioner and indicator housed in a 1/8 DIN case. This unit provides

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

NEUROLOGIC RESEARCH CORPORATION MODEL 2150 NEUROLOGIC RESEARCH CORPORATION FOUR DIGITAL INPUT / FOUR DIGITAL OUTPUT NETWORK NODE - Very compact design available in DIN Rail and NEMA 4X enclosures. - LonWorks FTT-10A network interface with all inputs

More information

Model XAV2 & XAV2-LED System Installation

Model XAV2 & XAV2-LED System Installation Model XAV2 & XAV2-LED System Installation 10/09/07 This document provides instructions for installing the Polara Push Button Station (PBS) and the XAVCU2 or XAVCU2-DC Control Unit. Mounting the Push Button

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

G540 MANUAL MULTIAXIS STEP MOTOR DRIVE

G540 MANUAL MULTIAXIS STEP MOTOR DRIVE G540 MANUAL MULTIAXIS STEP MOTOR DRIVE PRODUCT DIMENSIONS PHYSICAL AND ELECTRICAL RATINGS Minimum Maximum Units Supply Voltage 18 50 VDC Motor Current 0 3.5 A Power Dissipation 1 13 W Short Circuit Trip

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

Product Manual Dual SSR Relay Board

Product Manual Dual SSR Relay Board Product Manual 3053 - Dual SSR Relay Board Phidgets 3053 - Product Manual For Board Revision 0 Phidgets Inc. 2010 Contents 4 Product Features 4 Connections 5 Getting Started 5 Checking the Contents 5 Connecting

More information

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor 24/7 Sprinkler Monitor The Ultimate Rain/Freeze Sensor User s Manual PIONEER SALES, LTD. 5529 Redfield St. Dallas, TX 75235 Phone: (214) 276-0306 Fax: (214) 631-4218 Toll Free: 1-(866) 501-7745 1 Table

More information

GreenEye Monitor Specifications

GreenEye Monitor Specifications Number of Channels Power Monitoring Section 32 (expansion available in the future) Measurement POWER: True (or Real) Power using high speed volt and current sampling VOLTAGE: True RMS Accuracy Sampling

More information

Energy Management System. Operation and Installation Manual

Energy Management System. Operation and Installation Manual Energy Management System Operation and Installation Manual AA Portable Power Corp 825 S 19 TH Street, Richmond, CA 94804 www.batteryspace.com Table of Contents 1 Introduction 3 2. Packing List 5 3. Specifications

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0 4-Bay Rack Mount Chassis User Manual February 6, 2009 - v1.0 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM esata equipped

More information

High Voltage DC Meter

High Voltage DC Meter High Voltage DC Meter Javelin D PD644 0-300 VDC input NEMA 4X, IP65 front Scale in engineering units Sunlight readable LED display 4-20 ma analog output Two form C 3 A relays option RS-485 serial communications

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

Wireless Irrigation Control System

Wireless Irrigation Control System Wireless Irrigation Control System General introduction: Automated irrigation becomes a trend with the development of smart agriculture. In order to send appropriate amount water in proper time to your

More information

User's Guide. Digital Multimeter. Model MN42

User's Guide. Digital Multimeter. Model MN42 User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and

More information

Copyright White Box Robotics Inc. and Frontline Robotics Inc

Copyright White Box Robotics Inc. and Frontline Robotics Inc Disclaimer Working with electronics and installing the plastics will require care and patience. PROPER GROUNDING PROCEDURES before handling the electronics. Touching the robot chassis (which is common

More information