1 History: Version Date Name Change T. Eberhardt Translation M. Siegele Update Baudisch.SIP-Displaymodul32 Manual M.Schmidt Update Firmware V1.3, Config Door module Approval latest Version Date Name Division Initial Signature checked M.Schmidt DEV Sc checked checked checked checked PF VT User FE SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 1 / 22 SC/
2 1. Table of Content 1. Table of Content General Information Symbols Software History Hardware Versions Product Description General Information Software Version Control Elements and Connection Control Elements Connection to a Baudisch.SIP Door Module MAXI / PLUS Configuration General Information Configuration of the DisplayModule Examples Standard Application Two Connected Modules Three Connected Modules Examples Extended Index Range One Connected Module Two Connected Modules Functional Sequence Connect the KeypadModule 16B Number entry Code entry Central Call Short dialing Config-Mode Labeling Product details Technical data Connections Technical drawings Konformitätserklärung Customer Service SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 2 / 22 SC/
3 2. General Information 2.1. Symbols Warning of dangerous electrical voltage. This symbol points out important references, which must be followed to avoid injuries, as well as damages and malfunctions of the product. This symbol points out helpful references Software History Date Version Expansion Added the display visualization of the key inputs at the Keypad Module 16B Added new text languages Added new entries to configuration menu Bug fix: Switching from empty to not empty telephone directory was only possible via POR (Power On Reset) Initial version Display of firmware version in configuration menu added Configuration of an extended address range to use indexes 61 to Hardware Versions Date Version Expansion Initial version Improvement of the power supply (several modules connected to one SIP Door Module) SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 3 / 22 SC/
4 3. Product Description 3.1. General Information The Baudisch.SIP-Displaymodul32 is an extension for the SIP Door Module MAXI / PLUS. It allows the user to select and dial a defined range of telephone directory entries. You can connect up to 4 SIP-Display Modules to one SIP Door Module to list 4 telephone directory lists separately. In case of the connection of more than one module it is necessary to connect all further modules separately to a 24V supply. The Door Module is able to supply only one Display module with its integrated power supply! 3.2. Software Version! To make the SIP-Display module work, you have to use a Baudisch.SIP Door Module MAXI / PLUS (firmware 7.1 or higher) and activate the scan parameter.! Since firmware version 8i0 of Baudisch.SIP Door Module MAXI / PLUS the scan parameter for one Display Module is active in the factory settings.! The display visualization of the key inputs at the Keypad Module 16B is implemented since firmware version 8i0 of the Baudisch.SIP Door Module and the firmware version 1.3 of the Display Module Control Elements and Connection Control Elements Cursor keys up/down to select a entry Dial button to dial the selected entry SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 4 / 22 SC/
5 Connection to a Baudisch.SIP Door Module MAXI / PLUS Connect the ribbon cable which is supplied with the Display Module to the connector X1 IN of the Display Module to the connector X5 of the SIP Door Module MAXI / PLUS.! Please note that the Baudisch.SIP Door Module can power one Baudisch.CP-CAM, one Button Module (1B to 16B) and one Display Module simultaneously. Do you want to use multiple Display Modules, at the first module the jumper J3 must be open. At the second module, you can then use the screw terminal X4 to connect an external power supply Configuration General Information! Since firmware version 8i0 of Baudisch.SIP Door Module MAXI / PLUS the scan parameter for one Display Module is active in the factory settings. In order to use a Display Module to a Baudisch.SIP Door Module MAXI / PLUS, it is first necessary to inform the Door Module, the number of the connected Display Modules. This is done via the configuration software SIP Remote Control. You can download them for free on our website: SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 5 / 22 SC/
6 Before you can start SIP Remote Control, the following configurations need to be made in the web interface of the Door Module. Starting the Setup Menu. o Select Hardware Settings, enter the password and login (Default: 1234). Select Status / Remote control and make the following setting: o o o o o Click on Save. IP Address: It is recommended to type in the IP address of the PC which is used to configuration. If the broadcast address leave, the status messages are sent to all nodes in the network. Status Port (Send): 8112 (recommended) Remote Control port (receive): 8113 (recommended) Status: on Remote control: on Start SIP Remote Control o Open the file SIPControl.exe on the PC which is used to configuration SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 6 / 22 SC/
7 İ İ Make the following settings in SIP Remote Control: o o o Destination address: Destination address of the data packets. Enter the IP address of the SIP Door Module. Input port: 8112 (default). UDP port for incoming data. The setting must match the port for the status messages of the SIP Door Module. Output port: 8113 (default). UDP port for outgoing data. The setting must match the port for the remote control of the SIP Door Module. The specified ports may not be blocked by a firewall. Otherwise the SIP Remote Control can not connect to the Door Module. o o Unlock: Enter the unlock code Setup. (Case-sensitive!) The basic features include remote control of the relays and the camera IO s and to reboot the Door Module. By entering the unlock code the configuration is enabled. Press the Button open. A connection is established when data is displayed in the receiving area: By pressing the button Parameter / HW ID the following window opens: SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 7 / 22 SC/
8 İ İ İ İ In the field Address [16bit] type in 0x0606 and press Read. The current value stored in the EEPROM address 0x0606 is displayed. In the field Data [8bit] type in the value for the corresponding number of Display Modules you have connected to the SIP Door Module. Value No. of Display Modules 0x00 0 Display module default to FW 8h0 0x01 1 Display module default since FW 8i0 0x03 2 Display modules 0x07 3 Display modules 0x0F 4 Display modules Press on Write to store the value in the EEPROM. Close the window by pressing the button Close. Disconnect by pressing Close. Close the application by pressing EXIT. Set status and remote control in the web interface of the Door Module back to off. If you want to control only part of the connected Display Modules, see the associated value at chapter Search addresses for DisplayModule32 in the manual of the SIP Door Module. The phonebook entries will defined in the web interface of the SIP Door Module in section phonebook. The entries 1 to 60, see Call buttons on matrix modules (standard range). The entries , see Phonebook (Extended index range). Please note: The maximum available phonebook entries (60 in the standard range, 100 in the extended index rage) are each distributed to the connected Display Modules. No. of Display Modules No. of phonebook entries per Display Module standard range No. of phonebook entries per Display Module extended index range SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 8 / 22 SC/
9 Configuration of the DisplayModule32 To configure the Display Module set the jumper for a short time. The configuration is activated. If the jumper is permanently mounted in the configuration position, the configuration menu will start every power-on event. If there is no operation of a button for 20 seconds, the configuration menu will be left. Also you can exit the menu by selecting Exit. To scroll the options you have to use the two buttons located at the left. To enter the displayed option push the button on the right. After connecting the full amount of modules and choosing the range of the telephone directory, belonging to the module, you have to save by pushing the right button. Afterwards it will return to the main menu SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 9 / 22 SC/
10 Mod. Count shows the number of connected modules. Range shows the range of the telephone directory, which is to be assigned to the module. The Range depends on the index number. You can find the index number on the left hand side of each line in the telephone directory. Each Display Module must have an explicit index range.! Do not configure several Display Module to the same index range. Make sure the amount of connected modules ( Mod. Count) is programmed to the actual connected modules in each device. The following languages are available: German (de), English (en), French (fr), Italian (it), Dutch (nl) The setting Menu language can only be set to on of these languages. The setting is used for the configuration menu. The setting Text languages specifies the language for the normal text messages to the user. Multiple languages can be set here and will be displayed in sequence Examples Standard Application Two Connected Modules SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 10 / 22 SC/
11 Three Connected Modules SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 11 / 22 SC/
12 Examples Extended Index Range The extended index range is identified in the configuration menu with E. Make sure to configure all connected devices to the extended range. It is not permitted to combine the extended index range and the standard application One Connected Module Two Connected Modules SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 12 / 22 SC/
13 3.5. Functional Sequence After connecting to the power supply, the Display Module is in standby mode. It is waiting for a Signal from the Door Module to send a request for the telephone directory entries. If the signal was received, the entries are transmitted. A progress bar is shown in the display. If there are no entries in the configured range, the following will appear: In other case, the first entry is shown: To browse through the entries, use the buttons on the left hand side. The left button scrolls in ascending order, the other button in descending order. If the end of the list is reached, it jumps back to the first entry. If there is no call to a displayed entry for 10 seconds, the first entry is shown again. To call the displayed entry, push the right button. If there is an active dial the following is shown in the display: This sequence is shown independent of the call is missed or someone is speaking for 10 seconds. Afterwards it is possible to choose another entry and try a further call. In case of a call is active and another call is started error is shown: SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 13 / 22 SC/
14 3.6. Connect the KeypadModule 16B On connection X2 Our, it is possible to connect additional Display Modules (up to 3 Modules extra) and a Keypad Module 16B. The display visualization of the key inputs at the Keypad Module 16B is implemented since firmware version 8i0 of the Baudisch.SIP Door Module and the firmware version 1.3 of the Display Module Number entry Example Any number Sequence Button Number Button Display Code entry Example Sequence Code entry for door opener Button Code Button Display **** Correct code Blocking time after repeated incorrect code entry SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 14 / 22 SC/
15 Central Call Example Sequence Button Display Central Call Short dialing Example Any Short dial entries of the phonebook Sequence Button Short entry Display Config-Mode Example Start Config Mode Sequence Button Button Button Display Acoustic acknowledgment Dial timeout 02 IP address of the connected DoorModule SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 15 / 22 SC/
16 4. Labeling The text label for the viewing window, you can easily use a label printer. A good choice is a 12mm tape with a black lettering on a white background. Example: For Brother P-touch label printers we recommend a Brother TZe-231 Laminated Tape 12mm White (black letters on white background) with the following configuration: Configuration P-touch: Label Type: Normal Length: 82mm Size: 4mm Width: Normal Style: Normal With this configuration there are 16 characters available (including space character) SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 16 / 22 SC/
17 5. Product details 5.1. Technical data Connections and interfaces Screw type terminal X4 Grounding External supply +24VDC +/- 20%, GND EasyLan Screw terminals X5-7 Buttons Female connectors X1-2 Binary coded inputs for diode matrix modules / keypads +24VDC, GND, EasyLAN Physical characteristics Dimensions Without Front panel: (WxHxD): 82 x 82 x 37.7mm With Front panel: (WxHxD): x x 39.7mm Buttons: 19mm x1.3mm (from Front panel) Operating voltage 24V DC +/- 20% Typ. current consumption Environmental conditions Weight Protection class ca. 30mA Working temperature -20 C to +60 C Without Front panel (incl. Buttons): ca. 275g With Front panel (incl. Buttons): ca. 440g IP65 CE declaration DIN EN DIN EN DIN EN Industrial, scientific and medical equipment- Radio-frequency disturbance characteristics- Limits and methods of measurement Generic standards- Immunity for industrial environments Generic standards - Emission standard for residential, commercial and light-industrial environments SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 17 / 22 SC/
18 Configuration J1 Configmode inactive (Factory default) Configmode active J3 Jumper for redirection of the +24VDC power to X2 for additional modules. J3 closed (Factory default) J3 open SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 18 / 22 SC/
19 5.2. Connections X4 X1 X2 J3 J1 Terminal Pin Name Description X1 IN X2 OUT 1-8 Diode matrix Binary coded inputs for diode matrix modules / keypads 9-10 GND 11 EasyLAN EasyLAN Bus V Power output +24VDC Terminaö Pin Name Description X V External power supply 24VDC +/- 20% 3 4 EasyLAN EasyLAN Bus 5 6 GND 7 Schirm Protection Earth SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 19 / 22 SC/
20 5.3. Technical drawings SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 20 / 22 SC/
21 5.4. Konformitätserklärung SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 21 / 22 SC/
22 6. Customer Service Questions or problems during start-up? Please contact our support team: Manufacturer Baudisch Electronic GmbH Im Gewerbegebiet 7-9 D Wäschenbeuren Tel.: / Fax: / Mail: vertrieb@baudisch.de Web: SC_HB-EN_V120_Manual_Baudisch.SIP-Displaymodul32.doc 22 / 22 SC/
CPCI-PS24 24V-Power Supply
24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72
More informationPAC BI-DP BIM and 8701-CA-BI Carrier
June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series
More informationOperating Manual. English. Digital-Analog Converter DACON8-UMB.
English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationPosition indicator. Manual
Position indicator Manual Manufacturer NEW LIFT Steuerungsbau GmbH Lochhamer Schlag 8 82166 Graefelfing Tel Fax Mail +49 89 898 66 0 +49 89 898 66 300 info@newlift.de www.newlift.de Service line Tel +49
More informationApplication description for the KNXnet/IP Interface Web
Contents 1. General 1. General... 1 1.1 Basic information about the KNX/EIB BUS... 1 1.2 Application versions......1 1.3 Symbols...1 1.4 Function description... 2 1.5 Short description of the function
More informationQuick Start Guide. SEB-710 I/O Expansion board. Introduction
SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay
More informationINSTRUCTIONMANUAL. 24V motor control device for DIN-rail mounting
INSTRUCTIONMANUAL 24V motor control device for DIN-rail mounting Product group: shutters, sliding windows, sliding shutters Version: 1.0 Language: english Orig. Language: german (deutsch) Document: ------
More informationCreone AB Box 148 S Tranås SWEDEN Tel: +46(0) Fax: +46(0) Internet: All data
INSTRUCTION MANUAL Keybox 9000 Basic Keybox 9000 System Keybox 9000 Expansion KeyWin Light Creone AB Box 148 S-573 22 Tranås SWEDEN Tel: +46(0)140-38 61 80 Fax: +46(0)140-38 61 89 E-mail: mailbox@creone.com
More informationBARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.
BARIX IO12 I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL Version: 2.01 Date: 06/03/2014 For Firmware Version 10 Table of Contents
More informationE/A CAN. I /O Module for CAN Networks. Product Manual E-V0305.doc
E/A CAN I /O Module for CAN Networks Product Manual 07-04-04-E-V0305.doc Additional Supporting Documentation UL: 04-02-03 Absolute encoder with CAN UL: 07-01-05-06 635 - Product - Manual UL: 07-01-08-02
More informationKeypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual
secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.
More informationHardware Manual RM Display 2401
Hardware Manual RM Display 2401 Table of Contents 1 Legal Regulations...3 2 About the Display 2401...4 3 Important information for using RM Display 2401...5 4 Disposal...5 5 Installation...6 5.1 VESA 100
More informationCONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual
506 and 507 Relay Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationNetwork node WTT56.. A6V _en--_c Building Technologies
s Network node WTT56.. The WTT56.. network node is used to receive and handle the data transmitted by heat cost allocators, heat and water meters incorporated in a radio network. Storage of up to 500 metering
More informationGC 055. GSM Remote Monitoring. Operating and installation instructions
GSM Remote Monitoring Operating and installation instructions GC 055 GSM, GPRS Programmable Communicator Transmits input conditions/controls outputs Measures analogue data Access control system/dallas
More informationCONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual
5915 SDI-12 Interface Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationMonitoring Relays MRU, MRI, MRM
Monitoring Relays MRU, MRI, MRM 1 Features Voltage supply UC 12 48 V or UC 110 240 V Change-over contact Measuring inputs are separated galvanically from the supply Measuring range 0.1 480 VAC / 0.1 690
More informationHardware Manual RM CANview Gateway
Hardware Manual RM CANview Gateway 2008 RM Michaelides Software & Elektronik GmbH Donaustraße 14 D-36043 Fulda Germany cvgateway-hw-e.doc Table Of Contents 1 Legal Regulations... 3 2 About the CANview
More informationNISTA DEVICES GmbH 2013 All Rights Reserved. Door Access Control with the VoIP interface IP epcr Release 1.02
NISTA DEICES GmbH 2013 All Rights Reserved Door Access Control with the oip interface IP 39-60 epcr Release 1.02 1 NISTA DEICES GmbH 2013 All Rights Reserved IP Door Phones IP 39-60ePCR Quick Installation
More informationDORMA. Installation Manual Extension kit I/O module in the B6L 4P
DORMA Installation Manual Extension kit I/O module in the B6L 4P Contents Contents 1 General information......................... 3 1.1 Preface................................. 3 1.2 Correct use.............................
More informationInstallation and User Guide
D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect
More informationFG-260. Quick Startup Guide. Gateway between EtherNet/IP and PROFINET with PROFINET Controller functionality. Version: MMA-CA EN
Quick Startup Guide FG-260 Gateway between EtherNet/IP and PROFINET with PROFINET Controller functionality Version: MMA-CA-010260-EN-072015-1.02 Copyright 2014-2015 Softing Industrial Automation GmbH Disclaimer
More informationPK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.
C-Programmable Controller P00 Series The P00 Series of C-programmable controllers is based on the Zilog Z80 microprocessor. The P00 includes digital, serial, and high-current switching interfaces. The
More informationSiemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4
Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationLVX Control Unit. Features:
Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count
More informationPower supply. Interface technology in modular housing DIN rail devices, IM series. Features
Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating
More informationSynergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014
Upgrading a VersaTenn III controller with the Synergy Micro 2 Controller Introduction Synergy Controller is Tidal Engineering s line of Environmental l Test Chamber Controllers which and are designed to
More informationBNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide
BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical
More informationCONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual
503 and 50 Digital Input Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationMiR Bluetooth Box. Technical Documentation
MiR Bluetooth Box Technical Documentation Version 1.2 Software release 1.5 Release date: 11.04.2016 Table of contents 1 Introduktion...3 1.1 Feedback signal...3 1.2 Indication of relays states...3 2 Dimensions...3
More informationKvaser Linx J1587 User's Guide
Kvaser Linx J1587 User's Guide Copyright 2007-2011 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Last updated Thursday, 28 April 2011 We believe that the information contained herein was accurate in
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationDUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA
DUCM Hardware Manual DUCM Hardware Installation Manual This manual covers the DUCM hardware features and installation procedures. Effective: May 29, 2015 Niobrara Research & Development Corporation P.O.
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationAssembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN
Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions
More informationBNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide
BNI PBS-104-000-Z001 BNI PBS-302-000-Z001 BNI PBS-501-000-Z001 BNI PBS-502-000-Z001 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationUSER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION
USER MANUAL G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION TABLE OF CONTENTS 1. Introduction... 1 2. Interfaces... 2 3. Modem configuration using built-in keyboard and LCD.4 4.
More informationRS485 MODBUS Module 8I8O
Expansion Module 8 digital inputs, 8 digital outputs Version 2.2 12/01/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the
More informationCONTROL MICROSYSTEMS High Speed Counter Input Module. Hardware Manual
50 High Speed Counter Input Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationBaudisch.SIP-DoorStation
Elegant terminals for IP door communication. Voice and image High quality aluminium metal housing State-of-the-art VoIP technology Use of existing networks Technology 01 Compact door stations Our compact
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationMID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID
PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight
More informationIntercom User Manual v1.1
Intercom 102153-01 User Manual v1.1 Content of delivery - Intercom unit, art no. 102153-01 - DIN clips and screws - Intercom Manual (this document), art no. 162153-01M Art. No. 162153-01M v1.1c 2012-12-20
More informationEN Series / EXN. Telephone Entry & Access Control System. Quick Start Guide (EN-2A4) ( EXN )
EN Series / EXN Telephone Entry & Access Control System (EN-2A4) ( EXN ) Quick Start Guide (P/N: EN-2A4 / EN-2M4, EN-2A7 / EN-2M7, EN-2A10 / EN-2M10, and EXN) NOTE: This Quick start guide is applicable
More informationUser Manual Digital Input Module
EH-RIO2 Series RIO2-XDP4, -XDP8, -XDP16, -XAH4 Version 1.04 Copyright Hitachi Europe GmbH 2015. All rights reserved. DOCUMENT CHANGE SUMMARY REV PAGE REMARKS DATE EDITOR 1.4 All Created 18.06.2015 Winter
More informationCONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual
50 and 50 Digital I/O Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance Steacie Drive Telephone: 63-59-93 Kanata, Ontario Facsimile: 63-59-0 KK A9 Technical Support: -6-676
More informationI / O Expander. Instrument for torque control ASL 11/17
Instrument for torque control I / O Expander ASL 11/17 3000920 ENGLISH Pictograms WARNING It can be dangerous to use this machine if the operating instructions are not carefully followed. Before using
More informationOperating instructions RFID evaluation unit DTE / / 2016
Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4
More informationSK TU4-IOE-M12-C Part Number
SK TU4-IOE-M2-C Part Number 275 28 256 IO Extension Only qualified electricians are allowed to install and commission the module described below. An electrician is a person who, because of their technical
More informationData sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC
Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC ERP no.: 5206415 GCM MOD GMM EC.1 www.guentner.de Page 2 / 15 Contents 1 GCM MOD GMM EC.1...3 1.1 Functional description...3 1.2 Connections...
More informationBaudisch.CompleteSteel
Flexible IP door communication high quality, elegant, screwless Voice and image Stable one-piece stainless steel front plate Hidden fastening State-of-the-art VoIP technology Use of existing networks Technology
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationDF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS
DF PROFI II PCIe Installation Instructions V1.6 27.02.2017 Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS h:\dokumente\project\5302_df_profi_ii\anwenderdoku\installation\pcie\kunbus\version_1.5\df
More informationTechnical Manual Nova: Cabinet Security Management System (CSMS)
Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova
More informationHardware Manual RM Display 2501 S01..S04
Hardware Manual RM Display 2501 S01..S04 Table of Contents 1 Legal Regulations...3 2 About the Display 2501...4 3 Important information for using RM Display 2501...5 4 Disposal...5 5 Installation...6 5.1
More informationPCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1
Manual PCD3.C90 Revision History Date Modification Asked by: Version 14.09.09 E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1 22.09.09 Added E/A Bus Connector PCD3.K116 Müller.R 1.2 06.01.10
More informationCONTROL MICROSYSTEMS Analog Output Module. Hardware Manual
5304 Analog Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:
More informationBNI USB A501. USB IO-Link Master User's Guide. english
User's Guide english 1 2 4 Notes to the user 1.1 About this guide 1.2 Structure of the guide 1. Typographical conventions 1.4 Symbols 1.5 Abbreviations Safety 4 2.1 Intended use 4 2.2 General safety notes
More informationEPM Programmer EEPM1RA
EP01E - en EN Operating Instructions COPY epm001 EPM Programmer EEPM1RA 2004 Lenze gmbh & C0 KG No part of this documentation may be copied or made available to third parties without the explicit written
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationIV-30 Operating Manual for Pulse Distributor Cassette with potential separation
IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC
More informationINTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual
INTERQUARTZ Doorphone ID 201 Doorphone ID 202 Doorphone ID 204 User manual Contents 1 BASIC DESCRIPTION... 3 1.1 FEATURES... 3 1.2 SLIMDOORPHONE MODELS... 4 2 INSTALLATION... 4 2.1 OPENING, WIRING, WALL
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationDALI Professional Controller-4. Control unit Operating instructions
LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections
More informationType ME43. Quickstart
Type ME43 Fieldbus gateway büs to Industrial Ethernet, PROFIBUS DPV1, CC-Link Feldbus-Gateway büs zu Industrial Ethernet, PROFIBUS DPV1, CC-Link Passerelle bus de terrain büs vers Ethernet industriel,
More informationInstruction Manual IF2004/USB. 4-Channel RS422/USB Converter
Instruction Manual 4-Channel RS422/USB Converter The following sensors/systems can be connected to the 4-Channel RS422/USB Converter: Sensors of the ILD 1302 / 1402 / 1700 / 2200 / 2300 series Sensors
More informationICF-1150 Series Quick Installation Guide
ICF-1150 Series Quick Installation Guide Second Edition, March 2012 2012 Moxa Inc. All rights reserved. P/N: 1802011500011 Overview Introduction The ICF-1150 series fiber converters are equipped with a
More informationCoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...
Electronics & Software CoMo Logic Single-Channel y(t) ControlMonitor Type 5875A... The CoMo Logic monitor has a graphics display and charge mode input for monitoring time-dependent measurands in production
More informationI2C to DALI Interface
I2C to DALI Interface. Features DALI type II master I2C to DALI bridge Can transmit all 6 bit forward telegrams Receives 8 and 6 bit telegrams According to DIN EN 62386-03/20 Minimal external circuitry
More informationTPC70Display and Operator Panel
Issue 2017-09-13 Datasheet 2.60-10.070-01-EN Display and Operator Panel pplication The is a remote display and operator panel. It has a color TFT touchscreen with a screen size of 7 / 17,8 cm. The can
More informationBNI IOL Z046. IO-Link 1.1 sensor/actuator hub with extension port User's Guide
BNI IOL302002Z046 IOLink 1.1 sensor/actuator hub with extension port User's Guide Balluff Network Interface / IOLink BNI IOL302002Z046 Contents 1 General 4 1.1. Structure of the Manual 4 1.2. Typographical
More informationRN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011
www.rovingnetworks.com rn-174-ds v1.1 4/20/2011 WiFly GSX Super Module Features Development board containing the RN-171 module, status LEDs, power regulator Supports chip antenna (-C), PCB Trace antenna
More informationChannel Switch CS. General Operating, Maintenance and Installation Manual
Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September
More informationMounting and Operating Instructions (Simple Programming) Art.No..: , published: 10/2003
Mounting and Operating Instructions (Simple Programming) Art.No..: 732.29.125, published: 10/2003 Wall Terminal 2000 V.7 Art. No. Model Trans. Format Art. No. Model Trans. Format 917.01.101 Int., 1 Relay
More informationRKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series
RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series INSTALLATION & OPERATING GUIDE Rev. B P/N 3321515 www.securakeystore.com (800) 878-7829 sales@securakeystore.com COPYRIGHT 2001
More informationRN-174 WiFly Super Module
RN- WiFly Super Module Features Evaluation board for the RN- module Supports chip antenna (RN--C), PCB trace antenna (RN--P), wire antenna (RN--W), and U.FL connector for an external antenna (RN--U) Ultra-low
More informationEthernet/SIOX Gateway Applicable to firmware ver 1.0
ES2 Ethernet/SIOX Gateway p 2 TELEFRANG AB TABLE OF CONTENTS Ethernet/SIOX Gateway Applicable to firmware ver 1.0 General Description The ES2 module is a Gateway between a LAN/WAN Ethernet network and
More informationGEM80 & ewon Setup Quick Guide
Introduction to the ewon The ewon is an intelligent, programmable Ethernet Gateway, which can be used to bridge GEM 80 PLCs onto an Ethernet network, via the PLC serial port (Port3). This provides network-based
More informationM-bus web server. Meters and Energy Cost Allocation WTV676-HB6035
Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20
More informationEC-11 Ethernet Converter
EC-11 Ethernet Converter PSTN Contact ID to TCP Converter Installation and Operations Manual Version 8.H3.MID 1 Table of Contents About EC-11 Ethernet Converter... 3 Circuit Board Layout and Wiring Diagram...
More informationStepper Motor Driver Board. Instruction Note
Stepper Motor Driver Board Instruction Note August 31, 2012 General Photonics Corp. Ph: (909) 590-5473 5228 Edison Ave. Fax: (909) 902-5536 Chino, CA 91710 USA www.generalphotonics.com Document #: GP-IN-MDL-003-CONTROLB-10
More informationAS Keypad User Manual
AS Keypad User Manual Specifications Operating Voltage: 12~24 VAC/DC Current Draw: TBA Input: request-to-exit (for Relay 1) time out reed switch contact (for Relay 1) Output: Relay 1: N.O./N.C./Com. Output
More informationKSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-
KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced
More informationCSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.
CSMIO-MPG 6-axis Manual Pulse Generator (MPG) Module Rev. 2.0 copyright 2014 CS-Lab s.c. Index 1. General information...3 1.1 Signs used in this guide... 3 1.2 Standards compliance... 4 1.3 Technical data...
More informationWhisperPower Touch Display. User Manual Revision 1.2. WP 5.0 inch, WP 7.0 inch and WP 9.7 inch
WhisperPower Touch Display WhisperPower Touch Display WP 5.0 inch, WP 7.0 inch and WP 9.7 inch 1 WP 5.0 inch, WP 7.0 inch and WP 9.7 inch User Manual Revision 1.2 Copyright 2015 WhisperPower Kelvinlaan
More informationiloq S10 Online Configuration Guide
iloq S10 Online Configuration Guide Document version: 1.5 (Updated 02 May 2017) Contents 1 S10 Online System... 3 1.1 Printable Documentation... 4 1.2 Licenses...4 1.3 Net Bridge N100...4 1.3.1 Net Bridge
More informationOCIO GSM. M0148ITEN rev. 1 ENGLISH
OCIO GSM M0148ITEN rev. 1 ENGLISH 1 2 1. INTRODUCTION 2. INSTALLATION 2.1 Ocio Installation 2.2 SIM Card Installation 2.3 Installing the system with 1 Ocio 2.4 Installation of one expansion 2.5 Installation
More informationSIMPLY PRECISE USER MANUAL. ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation
USER MANUAL ADJUSTMENT TOOL For NUMERIK JENA Encoders with Online Compensation 2 Index 1. Features and Applications... 3 1.1 Functions of the ADJUSTMENT TOOL... 3 1.2 Dynamic Offset and Amplitude Control
More informationRTU560 Remote Terminal Unit Connections and Settings
Remote Terminal Unit Connections and Settings Communication Unit 560CMG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CMG10 1KGT 150 645 Operation
More informationVandal-resistant entrance panel
308040 LE05231AC-01PC-17W41 www.bticino.com Contents Vandal-resistant entrance panel Introduction 5 Warnings and recommendations 5 What s in your box 5 Description 6 Front view 6 Back view 7 Installation
More information1. Short description. 2. Features. 3. Technical parameters
1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.
More informationThomson Telecom S.A.S with a capital of RCS Copyright THOMSON 2005 All rights reserved 09/
Thomson Telecom S.A.S with a capital of 130 037 460 RCS 390 546 059 Copyright THOMSON 2005 All rights reserved 09/2005-1 www.speedtouchpartner.com ST2030 TM MGCP European Community Declaration of Conformity
More information