1 Agilent 5977 MSD Overview New GC/MSD Introduction January
2 New Agilent 5977 Series GC/MSD The 5977 is the new Agilent GC/MSD platform and replaces the 5975C and 5975E systems Improves performance with high sensitivity Extractor Ion Source MassHunter GC/MS Acquisition MassHunter and MSD ChemStation data analysis Integration of new Agilent Vacuum Pumps brings intelligent operation Direct Communication between 7890B and 5977A for more productivity 2
3 New Agilent 5977 Series GC/MSD What is the same as 5975? Quality Reliability Proven core technology since 5973/5975 Inert Ion Source Heatable Gold Quartz Quadrupole Triple Axis Detector High Energy Diode Triple Channel EM Detector Productivity Software (MSD ChemStation Data Analysis) 3
4 New Agilent 5977 Series GC/MSD What is new with 5977? Better Performance High Sensitive Extractor Ion Source Improved Agilent Vacuum Pump More Productivity Direct Communication 7890B 5977A Protect system Vent the system faster Power save (Sleep/Wake) MassHunter Software Data Acquisition (Method/Sequence) Data Analysis 4
5 New Extractor Ion Source for 5977 Why the Extractor EI Source? Increase in ion count True increase in sensitivity Better trace level precision Lower IDL and MDL Proven sensitivity increase demonstrated with over Series GC/TQ! Page 5
6 Comparison between Inert Ion Source and Extractor Ion Source Repeller (Push) Ionization area Ions Drawout Plate Extractor Lens (Pull) Ion Focus Lens Entrance Lens Inert Ion Source Mass Filter Extractor Source More ions to Mass Filter Page 6
7 How Extractor Ion source with Etune be seen in the Chromatogram? Blue Extractor 40ppb solution (SVOC) Red Standard 40ppb solution (SVOC) 7
8 More improvements on 5977 s Extractor Ion Source: Improved Thermal Profile Why is this important? Better performance of high boilers i.e. PAH even at lower concentration! Good repeatability of PAH even at the trace level (5ppb)!! 10 Injections 80 min analysis Improvement for better Mass Spectrometer of Gas Chromatograph Page 8
9 Sensitivity Specifications of the 5977 Full Scan EI Specification: S/N - Signal-to-Noise The 5977 in scan mode has some background noise even if only OFN standard is injected, therefore the traditional Signal-to-Noise (S/N) is used as specification. Agilent s 5977 has the highest S/N (1500:1) with Extractor Ion Source among the SQ system. (1pg OFN) SIM Specification: IDL - Instrument Detection Limit Agilent 5977A uses this sensitivity specification for detection techniques where no or little noise is generated, such as when OFN standard is injected. IDL is a new specification for SIM, but have been used with MS/MS for over a year. 9
10 5977A GC/MSD IDL Specification IDL is a statistically derived value from the precision (%RSD) of 8 consecutive, splitless injections of 100fg OFN at 99 % confidence level. The more precise instruments (lower %RSD) will generate lower IDLs. The Agilent 7890B/5977A with an ALS or CTC autosampler has the following specifications: Ion Source type High Vacuum pump type IDL of OFN by 8 replicates of ALS* Extractor Source Turbo Pump 10fg Inert Source Turbo Pump Diffusion Pump 24fg 30fg These are installation specification, performed on customer site, immediately after installation and carry a lot more value than a reference specs. *Systems without an Autosampler will have only S/N specification. 10
11 Why IDL specification is useful for the 5977 in SIM? Influence of Noise in S/N specs In SIM (or MS/MS) when the Noise is too low, such as during acquisition of an OFN standard, S/N results may not give the best characterization If the noise level is insignificant - varies a lot and too low- the derived value from it (S/N) also becomes insignificant Value of IDL IDL is derived from reproducibility/precision results, the same metrics most users utilize every day in their work. The IDL statistical process is the same used for Method Detection Limit calculations, and the %RSD values are tools to monitor analytical performance IDL characterizes the whole system AS, GC, MS- giving confidence in overall reliability. It is the results of 8 consecutive injections, unlike S/N in a single shut, which can be influenced by many parameters/conditions 11
12 The Influence of the low Noise on S/N values Same Data File, RMS, 5 Second Noise Region A 0.01 min. shift in the noise region resulted a 6000 higher S/N value. When the noise is insignificant (low), the derived S/N value is also insignificant! Noise region: 5.65min min S/N: S/N Noise region: 5.66min min S/N: 3335 S/N Noise region: 5.65min-5.73 min Noise region: 5.66min-5.74 min 12
13 Better HW Features: Agilent Turbo Pump (V304) Innovation for: Higher pumping performance especially for He and H 2 High reliability lower cost of operation Agilent Quality Standard TwisTorr 304 FS Press release : Page 13
14 Better HW Features: Agilent Rough Pumps New DS42i High performance Energy saving design Inverter mode not active with diff pump New IDP-3c High performance Oil-free scroll pump NH 3 CI compatible with Agilent Quality Standards Page 14
15 Better HW Features: Power consumption saving of MSD by Inverter Pump (DS42i) What this means to the laboratory cost of ownership? W W 0 Operation mode Sleep Mode 15
16 Example of Cost simulation of saving power with Agilent 7890B/5977A at Environmental Lab Assumptions GC/MSD cycle time: 40 minutes (30min for data acq./10 min for cool down & prep) Sample: 30 samples/day Working day: 5 days/week, no operating on Sat/Sun GC/MSD wake time = 40 min/sample * 30 samples * 5 days/week = 6,000 min/week = 100 hours/week = 32 kwh GC/MSD sleep time = 168 hours/week 100 hours/week = 68 hours/week = 13 kwh Total Power usage (1 week) = 45 kwh (with Sleep mode) Total Power Usage (1 week) = 54 kwh (without Sleep mode Weekly MS Power saving per instrument = 9kWh (17%) 16
17 3 ways to go to Sleep mode From the menu item of MassHunter From the 7890B Keypad From the Sequence Keyword 17
18 Key features of Direct Communication between 7890B and 5977A Sleep/Wake mode In sleep mode, MSD will go to the Power save mode (320W 190W) Laboratory Operating Cost Reduction (see the previous slide for detail) Safety Control If 5977A MSD Pumps fail, 7890B will shut off the gas supply for protecting GC/MSD system. Helium Carrier gas : This prevents wasting gas. Hydrogen Carrier gas: This reduces the risk of explosion in MSD. Cool Down MSD Faster (FastVent) When MSD Vent Cycle started, GC will cool down MSD analyzer at the optimum gas flow to MSD. Less time to wait for cooling down MSD analyzer (40 min 25 min when cooling down from 280C to 100C) Page 18
19 MassHunter GC/MS Acquisition for GC/MSD Unified GC/MS Acquisition and MassHunter Data Analysis; with MSD ChemStation workflow for GC/MSD 19
20 GC/MSD Software MassHunter Qual MH MassHunter Quant CS MassHunter GC/MS Acquisition MSD ChemStation DA And Use Either MassHunter Data Analysis OR MSD ChemStation Data Analysis G1701FA 20
21 The Value of G1701FA Software All Inclusive G1701FA Software Package MassHunter GC/MS Acquisition MSD ChemStation DA MassHunter Quantitative Analysis MassHunter Qualitative Analysis MassHunter Qual MSD ChemStation Data Analysis 21CFR11 Compliance tools (Acquisition and MH Quantitative Analysis) GC/MS and LC/MS Translators Collated User Information Workflow guides, Video Tutorials, all in one location Support 1yr Upgrade, Updates, and Phone Support Training and Familiarization options MassHunter Quant 21
22 MassHunter GC/MSD Rollout Plan Feb 2013: Add GC/MSD systems 5975 & 5977 Series GC/MSD 7890B & 7820A 7697A HSS Late 2013: Expand Compatibility 5973 Network 6890 Network & 6850 GC MH EnviroQuant Continue MassHunter GC/MS and GC support 7000 Series Triple Quad GC/MS 7200 Series Q-TOF GC/MS MH DrugQuant GC and GC/MSD Data Analysis with MassHunter OR MSD ChemStation modes 22
23 ASK When can I start using MassHunter if I buy a 5977 Series GC/MSD? ANSWER Anytime! Without added cost! 23
24 GC/MSD Acquisition Methods MSD Productivity ChemStation MassHunter GC/MS Acquisition GC/MS Acquisition Methods are Transparent from MSD ChemStation to MassHunter GC/MS (Except PAL) 24
25 Migrate MSD ChemStation Data to MassHunter Data MassHunter Quant MSD ChemStation (.D) Data MassHunter Qual WorkStation (.SMS) Data Generic (.CDF) 25
26 Migrate MSD ChemStation Quantitative Methods to MassHunter MassHunter Quant Method MSD ChemStation (QDB.MTH) Method WorkStation (.mth) 26
27 Expanded Capabilities: 7890B/5977A Improving the Industry Standards for GC/SQ Higher Ion Count Extractor EI source Increased ion count S/N > 1500:1 IDL < 10 fg (industry first) Improved thermal profile Better Vacuum by Agilent Pump New Agilent V304 Turbo TwisTorr Molecular Drag technology Improved pumping light gases H 2 (220 L/s); He (255 L/s) Agilent Floating Suspension Longer life Quiet operation Safety/Protection Vacuum failure Shut off gas (He or H2) Save Time & Energy Sequence Scheduler Standby post run Ready to run from standby Bake Mode as needed Factory backflush option Fast Vent capability DS42i rough pump standby power reduction Faster Scanning 20,000 u/s But best choice of fast scanning GC/MS is GC/QTOF 7890B GC Features EMF, calculator, etc. All of 5975 s features also built in 5977, such as Hot Gold Quad, SIM/Scan, Gain tuning, Triple-Axis Detector, Trace Ion Detection, Auto CI, etc.. 27
28 7890B/5977A GC/MS Solution Portfolio Driving Business Value and Success Proven 7890 and 5977 Reliability MassHunter & ChemStation SW Integrated Intelligence Improved Performance Greater Operating Efficiency Expanded Accessories and Options 28
Agilent 6400 Series Triple Quadrupole LC/MS System
Agilent 6400 Series Triple Quadrupole LC/MS System Quick Start Guide Where to find information 4 Getting Started 6 Step 1. Start the Data Acquisition software 7 Step 2. Prepare the LC modules 13 Step 3.
More information5975 inert MSD. Chris Sandy European GC-MS Product Specialist Agilent Technologies
inert MSD Chris Sandy European GC-MS Product Specialist Agilent Technologies Welcome to our e-seminar: Introduction of the new inert MSD for expanding your application capabilities Presenter: Chris Sandy
More informationAgilent MassHunter Qualitative Data Analysis
Agilent MassHunter Qualitative Data Analysis Qualitative Navigator B.08.00 Presenters: Kevin Costalunga Stephen Harnos With Matt Leyden & Kevin Costalunga 1 MassHunter Webinar Series MassHunter Qualitative
More informationAgilent GC, MS, and ALS
Installation Checklist Verify Site Preparation for Your GC, GC/MS, and ALS 2 GC and MS Installation 2 Automatic Liquid Sampler (ALS) Installation 6 Acquisition Software and PC Installation 7 Performance
More informationGetting Started. Environmental Analysis Software
Getting Started Environmental Analysis Software Environmental Software Overview The Environmental software is a data acquisition and data analysis package designed to assist you in complying with United
More informationAgilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide
Agilent MassHunter Drug Analysis Mode Using Quantitative Analysis Workflow Guide Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including
More informationAgilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS
Agilent MassHunter Workstation Software 7200 Accurate-Mass Quadrupole Time of Flight GC/MS Familiarization Guide Before you begin 3 Prepare your system 3 Prepare the samples required for data acquisition
More informationThe Agilent 5975 inert MSD: New Tools for the Forensic Analyst
The Agilent 5975 inert MSD: New Tools for the Forensic Analyst Chemical Analysis Group Bruce D. Quimby, Ph.D. Senior Applications Chemist Agilent Technologies Wilmington, Delaware March 2,2006 Page 1 The
More informationGetting the most from your Agilent Instruments: New Advancements in OpenLAB CDS Instrument Control
OpenLAB CDS Getting the most from your Agilent Instruments: New Advancements in OpenLAB CDS Instrument Control Steve Miller October 2013 New Release: OpenLAB CDS A.01.05 7890B Series GC Support All New
More informationQuick Reference. 5973N and 5973 inert Mass Selective Detector Local Control Panel (LCP)
Quick Reference 5973N and 5973 inert Mass Selective Detector Local Control Panel (LCP) Using the Local Control Panel The Local Control Panel (LCP) lets you determine the readiness and performance of the
More information5973 Network Mass Selective Detectors
www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment 5973 Network Mass Selective Detectors. General The 5973Network products are
More informationAgilent 7890GC. Firmware Bulletin. Revision B and A External use only
Agilent 7890GC Firmware Bulletin Revision B.02.04.2 and A.01.16 External use only About this Document This document provides the firmware changes used for the following GC Systems 7890B (G3440B) 7890A
More informationAgilent MassHunter Easy Access Software
Agilent MassHunter Easy Access Software Quick Start Guide Where to Find More Information 3 Installation 4 Sharing Configurations with Multiple Instruments 10 Installed Files 11 Using Easy Access Software
More informationAgilent G1732AA MSD Security ChemStation
Agilent G1732AA MSD Security ChemStation User Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004 No part of this manual may be reproduced in any form or by any means (including electronic
More informationAgilent 6100 Series Quad LC/MS System
Agilent 6100 Series Quad LC/MS System Quick Start Guide Where to find more information 2 Configuration Diagrams 3 ChemStation Views 5 Basic Operation 20 Operating Tips 27 Troubleshooting Tips 29 Safety
More informationCustomer Information. Service Engineer s Responsibilities. Additional Instruction Notes. System Information. Agilent Technologies
Thank you for purchasing an Agilent GC/MS system solution. This checklist is used by the installing engineer to ensure that the instrument and associated systems are correctly installed, upgraded and functioning
More informationAgilent GC/MSD Instructions
Agilent GC/MSD Instructions GC/MS SAMPLE PREPARATION: Sample Components to Avoid Completely: The following should never be injected: metals, strong acids or bases, salts, oligomeric and polymeric material.
More informationAgilent 5977 Series MSD System
Agilent 5977 Series MSD System Quick Start Agilent Technologies Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationHow to Run the CASPiE GCMS
How to Run the CASPiE GCMS A GCMS (gas chromatograph-mass spectrometer) can be used to separate and identify complex mixtures. You will use the CASPiE GCMS to acquire the mass spectrum of your anitviral
More informationAgilent G1701DA MSD ChemStation
Agilent G1701DA MSD ChemStation 5973 MSD / ChemStation Quick Reference Agilent Technologies What s New in Revision D.01.00 A new toolbar has been added to the Top view and an expanded set of toolbars have
More informationAgilent MassHunter GCMS Data Acquisition for the 5977 Series MSD System
Agilent MassHunter GCMS Data Acquisition for the 5977 Series MSD System Getting Started Agilent Technologies Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form
More informationAgilent 7890 Series Gas Chromatograph
Agilent 7890 Series Gas Chromatograph GC Software Features Overview Agilent Technologies Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including
More informationSIM Direct Inlet Probe. Agilent 5975 MSD. Agilent 7000 Triple Quadrupole
SERVICE MANUAL SIM Direct Inlet Probe for Agilent 5975 MSD and Agilent 7000 Triple Quadrupole (Firmware V.1.10) - 1 - Document History Edition 7075e 10/2010, from Firmware / Software Version V1.10 and
More informationUPDATING PESTICIDE RETENTION TIME LIBRARIES FOR THE AGILENT INTUVO 9000 GC
UPDATING PESTICIDE RETENTION TIME LIBRARIES FOR THE AGILENT INTUVO 9000 GC How to Update Retention Time Libraries on Intuvo Introduction When applying methods to a new gas chromatographic (GC) system,
More informationAgilent MassHunter Workstation Software for Triple Quad LC/MS
Agilent MassHunter Workstation Software for Triple Quad LC/MS Upgrade Guide Step 1. Prepare for installation 2 Step 2. Install the Acquisition program (includes Optimizer and Study Manager) 3 Step 3. Install
More informationAgilent GC Drivers A
Agilent Technologies, Inc. Agilent GC Drivers A.03.02.019 Release Notes 1 14 2016 WHAT S NEW IN AGILENT GC DRIVERS VERSION A.03.02.019... 2 SUPPORTED PLATFORMS... 2 SUPPORTED AGILENT GC HARDWARE... 3 GC
More informationAgilent OpenLAB CDS. Version 2.2. Release Notes. OpenLAB CDS Release Notes 1
Agilent OpenLAB CDS Version 2.2 Release Notes OpenLAB CDS Release Notes 1 Introduction This document provides a listing of the major feature modifications made in each release of the Agilent OpenLAB Chromatography
More informationRetention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?
Retention Time Locking with the MSD Productivity ChemStation Technical Overview Introduction A retention time is the fundamental qualitative measurement of chromatography. Most peak identification is performed
More informationFatty Acid Methyl Ester (FAME) RTL Databases for GC and GC/MS
Fatty Acid Methyl Ester (FAME) RTL Databases for GC and GC/MS User contributed by: Frank David and Pat Sandra Research Institute for Chromatography Pres. Kennedypark 20, B-8500 Kortrijk, Belgium and by:
More informationAgilent Intuvo 9000 Gas Chromatograph
Agilent Intuvo 9000 Gas Chromatograph Operation Manual Agilent Technologies Notices Agilent Technologies, Inc. 2016 No part of this manual may be reproduced in any form or by any means (including electronic
More informationAgilent G1732AA MSD Security ChemStation
Agilent G1732AA MSD Security ChemStation User s Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form or by any means (including electronic
More informationAndreas Reimann Berlin im Juli 2009
Agilent Technologies ASMS 2009 Andreas Reimann Berlin im Juli 2009 New Triple Quad LC/MS Portfolio 6410, 6430 & 6460 Page 2 Comparison of 6400 Series QQQs 6410BA 6430 6460 Sensitivity: 1 pg reserpine S/N
More informationGetting low-resolution GC-MS data on the JEOL GCMate Introduction
Getting low-resolution GC-MS data on the JEOL GCMate Introduction GC-MS is a technique that combines gas phase separation and mass-based detection/characterization of analytes. It s a very sensitive method
More informationTitle: Release of MassHunter Quantitative Analysis B SP1 Build 388.1
Subject: Supersedes: G3335AA MassHunter Software-193 Title: Release of MassHunter Quantitative Analysis B.06.00 SP1 Build 388.1 Service Note Number: Serial Numbers: N/A Summary: MassHunter Quantitative
More information5973N and 5973 inert Mass Selective Detector
5973N and 5973 inert Mass Selective Detector Hardware Installation Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including
More informationAgilent G2727AA LC/MS Data Browser Quick Start
What is Data Browser? Agilent G2727AA LC/MS Data Browser Quick Start A guide to get started with Data Browser Use this quick reference guide as a road map for your first steps with the Data Browser software,
More informationAgilent G1732BA MSD Security ChemStation
Agilent G1732BA MSD Security ChemStation User s Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means (including electronic
More informationCTC Sampler Implementation in the GC/MSD ChemStation. Technical Overview. Introduction
CTC Sampler Implementation in the GC/MSD ChemStation Technical Overview Introduction Diversifying application requirements among laboratories has lead to the need for flexible and expanded sample introduction
More informationSteps for LCMS-8040 Triple Quadrupole
Steps for LCMS-8040 Triple Quadrupole June 2017 Version 2 A. Data Acquisition 1. Check lights on MS. There should be a total of three lights lit by LED. One of them is blinking. Power Blinking Gas Status
More informationSPS3 autosampler. Innovation with Integrity. For the Bruker 810/820-MS. Mass Spectrometry
SPS3 autosampler For the Bruker 810/820-MS Innovation with Integrity Mass Spectrometry SPS3 autosampler The SPS3 Sample Preparation System, Bruker s fastest-ever spectroscopy autosampler, meets the diverse
More informationGC-MS ChemStation Reference Guide. Last Updated July 2014
GC-MS ChemStation Reference Guide Last Updated July 2014 Overview GC-MS Instrumentation Description Sequence Programming Data Analysis Tips and Tricks Method programming reference is for your enrichment
More informationAgilent G6855AA MassHunter Personal
Agilent G6855AA MassHunter Personal Forensic Toxicology Database Kit Quick Start Guide What is the MassHunter Personal Forensic Toxicology Database Kit? 1 Kit Content 2 Where to find more information 4
More informationXcalibur. QuickQuan. User Guide. XCALI Revision C July For Research Use Only Not for use in Diagnostic Procedures
Xcalibur QuickQuan User Guide XCALI-97195 Revision C July 2007 For Research Use Only Not for use in Diagnostic Procedures 2007 Thermo Fisher Scientific Inc. All rights reserved. Microsoft, Access, Excel,
More informationRelease Note for Agilent LC and CE Drivers Revision A.02.17
Release Note for Agilent LC and CE Drivers Revision A.02.17 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.17. The Agilent LC and CE Driver
More informationAgilent G1701DA GC/MSD ChemStation
Agilent G1701DA GC/MSD ChemStation Drug Analysis Software Getting Started Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form or by any means
More informationAgilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide
Agilent G6854AA MassHunter Personal Pesticide Database Kit Quick Start Guide What is the MassHunter Personal Pesticide Database Kit? 1 Kit Content 2 Where to find more information 3 Before You Begin 4
More informationAgilent G2070BA GC ChemStation
Agilent G2070BA GC ChemStation Familiarization Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic
More informationAgilent Triple Quadrupole LC/MS Peptide Quantitation with Skyline
Agilent Triple Quadrupole LC/MS Peptide Quantitation with Skyline Workflow Guide A Peptide Optimization B Review Results in Skyline Create QQQ method in Skyline Edit Skyline settings Import peptides into
More informationAgilent 1290 Infinity 2D-LC Solution
Agilent 1290 Infinity 2D-LC Solution A new flexible and userfriendly 2D-LC solution for the most complex samples Michael Frank Marketing Manager Analytical HPLC LPSD, Waldbronn, Germany April, 13 th 2012
More informationQ Exactive HF-X QuickStart Guide
Q Exactive HF-X QuickStart Guide About this Guide Q Exactive HF-X Tune This Q Exactive HF-X QuickStart Guide gives an introduction on setting up and using the Thermo Scientific Q Exactive HF-X mass spectrometer.
More informationAgilent 5975 Series MSD
Agilent 5975 Series MSD Operation Manual Agilent Technologies Notices Agilent Technologies, Inc. 2010 No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationOperating Manual. GC-APPI Inferface for:
Operating Manual GC-APPI Inferface for: Q-Exactive TM MS, Exactive TM MS, and LTQ Orbitrap TM Series MS P/N: MC510000, P/N: MC511000, P/N: MC512000 Revision C GC-APPI-Interface 2016 MasCom Technologies
More informationMassHunter Pesticides PCD or PCDL Quick Start Guide
MassHunter Pesticides PCD or PCDL Quick Start Guide What is the MassHunter Pesticides PCD or PCDL? 3 Kit Contents 4 Where to find more information Before You Begin 7 Installation 7 Required reagents and
More informationIntegration of GC/MSD ChemStation with OpenLAB ECM
Integration of GC/MSD ChemStation with OpenLAB ECM Technical Overview Introduction OpenLAB Enterprise Content Manager (ECM) is a Web-based electronic library that provides a secure storage place for all
More informationAgilent G3250AA LC/MSD TOF System
Agilent G3250AA LC/MSD TOF System Concepts Guide The Big Picture Agilent Technologies Notices Agilent Technologies, Inc. 2003-2007 No part of this manual may be reproduced in any form or by any means (including
More informationNew Features of Deconvolution Reporting Software Revision A.02 Technical Note
New Features of Deconvolution Reporting Software Revision A.2 Technical Note Authors Mike Szelewski Chin-Kai Meng Agilent Technologies, Inc. 28 Centerville Road Wilmington, DE 1988-161 USA Abstract Deconvolution
More informationAgilent 7890B Gas Chromatograph
Agilent 7890B Gas Chromatograph Operation Manual Agilent Technologies Notices Agilent Technologies, Inc. 2015 No part of this manual may be reproduced in any form or by any means (including electronic
More informationAgilent G1701DA GC/MSD ChemStation
Agilent G1701DA GC/MSD ChemStation Drug Analysis Software Getting Started Agilent Technologies Notices Agilent Technologies, Inc. 2006 No part of this manual may be reproduced in any form or by any means
More informationThermo Xcalibur Getting Started (Quantitative Analysis)
Thermo Xcalibur Getting Started (Quantitative Analysis) XCALI-97207 Revision B September 2010 2010 Thermo Fisher Scientific Inc. All rights reserved. Xcalibur, Surveyor, and Accela are registered trademarks
More informationApplication Note. Abstract. Authors. Forensic Toxicology
An Application Kit for the Screening of Samples for Analytes of Forensic Toxicological Interest using TOF or Q-TOF LC/MS with a Personal Forensic Toxicology Database Application Note Forensic Toxicology
More informationSkyline High Resolution Metabolomics (Draft)
Skyline High Resolution Metabolomics (Draft) The Skyline Targeted Proteomics Environment provides informative visual displays of the raw mass spectrometer data you import into your Skyline documents. Originally
More information5973N and 5973 inert Mass Selective Detectors
5973N and 5973 inert Mass Selective Detectors Site Preparation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including
More informationCustomer Information. Service Engineer s Responsibilities. Additional Instruction Notes. Agilent 6230B Series TOF LC-MS System Installation Checklist
Thank you for purchasing an Agilent instrument solution. This checklist is used by the installing engineer to ensure that the instrument and associated systems are correctly installed, upgraded and functioning
More informationAgilent 7820A Gas Chromatograph
Agilent 7820A Gas Chromatograph Operating Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced in any form or by any means (including electronic storage
More informationQ Exactive HF-X Software Manual
Q Exactive HF-X Software Manual Exactive Series 2.9 BRE0012262 Revision A May 2017 Q Exactive HF-X Software Manual Exactive Series 2.9 BRE0012262 Revision A May 2017 Legal Notices 2017 Thermo Fisher Scientific
More informationHardware Guide. AB SCIEX QTRAP 5500 System
Hardware Guide AB SCIEX QTRAP 5500 System D1000079384 E May 2010 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment. This document
More informationAgilent MassHunter LC/SQ ChemStation Integration Software
Agilent MassHunter LC/SQ ChemStation Integration Software Quick Start Guide What is the Agilent MassHunter LC/SQ ChemStation Integration Software? 2 Installation 4 Getting Started 5 LC/SQ Chemstation To
More informationAgilent G1701DA MSD Productivity ChemStation Software
Agilent G1701DA MSD Productivity ChemStation Software (version D.01.00 or later) Installation Manual Agilent Technologies Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced
More informationTutorials. Saturn GC/MS Workstation Version 5.4. Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA /usa
Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA 94598-1675/usa Saturn GC/MS Workstation Version 5.4 Tutorials Varian, Inc. 1999 03-914765-00:Rev. 1 1 Contents How to Exercises...1 Overview...1
More informationSkyline MS1 Full Scan Filtering
Skyline MS1 Full Scan Filtering The Skyline Targeted Proteomics Environment provides informative visual displays of the raw mass spectrometer data you import into your Skyline project. These displays allow
More informationWorkflow Optimization with EZ Access and ChemStation Browser. Tony Brand, Ph.D., Agilent Technologies, Inc., North Carolina, USA
Welcome to our E-Seminar: Workflow Optimization with EZ Access and ChemStation Browser Presenter: Tony Brand, Ph.D., Agilent Technologies, Inc., North Carolina, USA Contents ChemStation version A.10.02
More information5975 Series Mass Selective Detectors
5975 Series Mass Selective Detectors Site Preparation Guide Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form or by any means (including
More informationRetention Time Locking Operation
Retention Time Locking Operation Retention Time Locking Database 32-1 What is Retention Time Locking? The ability to precisely match chromatographic retention times in any Agilent GC system to those in
More informationRelease Notes. Analyst Software
Release Notes Analyst 1.5.1 Software D1000092608 B May 2010 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment. This document
More informationRelease Note for Agilent LC and CE Drivers Revision A.02.15
Release Note for Agilent LC and CE Drivers Revision A.02.15 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.15. The Agilent LC and CE Driver
More informationAgilent OpenLAB Chromatography Data System (CDS) ChemStation Edition
Agilent OpenLAB Chromatography Data System (CDS) ChemStation Edition Supported Instruments and Firmware Guide Notices Agilent Technologies. 2010, 2011-2017 No part of this manual may be reproduced in any
More informationSmartSoft AES Operator s Guide
SmartSoft AES Operator s Guide Part No. 702064 Rev. A Physical Electronics USA, PHI, SMART-Tool, SmartSoft, MultiPak and Watcher are trademarks of ULVAC-PHI, Inc. All other trademarks are the property
More informationAgilent RapidFire 300 High-throughput Mass Spectrometry System
Agilent RapidFire 300 High-throughput Mass Spectrometry System Data Analysis Guide Installation 2 To install Agilent RapidFire Integrator software 2 Preparing Data Collected in Plates Mode for RapidFire
More informationAutomated Fraction Re-Analysis Does it really make sense?
Automated Fraction Re-Analysis Does it really make sense? Presented by: Udo Huber 1995 PHD in organic chemistry from the University Karlsruhe/Germany 1996-97 Postdoctoral fellow at the University of Hawai
More informationAgilent G1978B Multimode Source for 6100 Series Single Quad LC/MS
Agilent G1978B Multimode Source for 6100 Series Single Quad LC/MS Set-Up Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any
More informationAgilent 6300 Ion Trap LC/MS Systems Quick Start Guide
Agilent 6300 Ion Trap LC/MS Systems Quick Start Guide A guide to help you get started with the Agilent 6300 Series Ion Trap LC/MS system What is the Agilent 6300 Series Ion Trap LC/MS System? 2 Where to
More informationAn Improved Compact GC For Field Testing
An Improved Compact GC For Field Testing NovaTest P300 Integrated Compact Gas Chromatograph Nanova Environmental, Inc. 1 VOCS ARE EVERYWHERE Do you think volatile organic compounds (VOCs) only exist in
More informationChromeleon / MSQ Plus Operator s Guide Document No Revision 03 October 2009
MSQ Plus Chromeleon / MSQ Plus Operator s Guide Document No. 065322 Revision 03 October 2009 Chromeleon / MSQ Plus Operator s Guide 2009 by Dionex Corporation All rights reserved worldwide. Printed in
More informationAgilent G1978B Multimode Source for 6410 Triple Quad LC/MS
Agilent G1978B Multimode Source for 6410 Triple Quad LC/MS Set-Up Guide Agilent Technologies Notices Agilent Technologies, Inc. 2008 No part of this manual may be reproduced in any form or by any means
More informationDetailed procedures, operation instructions, maintenance, and emergency contact information list is attached.
GC/FID Standard Operating Procedure Environmental health and Safety (EH&S) 2809 Daley Drive Ames, IA 50011-3660 Phone: (515)-294-5359 Fax: (515)-294-9357 www.ehs.iastate.edu Procedure: Department: Bioeconomy
More informationUPGRADE PROGRAM. V70 Series Pumps vs V81T Series Pumps
VARIAN vacuum technologies UPGRADE PROGRAM V70 Series Pumps vs V81T Series Pumps Technical Memo Technical Memo - 1 - V70 series vs V81-T INDEX Outline drawings ISO63 3 Outline drawings CF2-¾ 4 Outline
More informationSoprane II Documentation
Soprane II Documentation p. 1 / 198 Table of contents 1. INTRODUCTION 6 2. INSTALLATION 6 3. ANALYZER CONFIGURATION 8 3.1. Creation 9 3.1.1. Analyzer creation with network connection 11 3.1.2. Analyzer
More informationAgilent G9250AA Pesticides and Environmental Pollutants Database
Agilent G9250AA Pesticides and Environmental Pollutants Database Read Me Introduction 1 Overview 2 Compounds in the Database 4 Analytical Methods 4 VLOOKUP Function in Excel 5 Excel Shortcut Key Strokes
More informationMIMA V 1.0. MS IMS Mapper. Peak Identification in Ion mobility Spectrometry
MIMA V 1.0 MS IMS Mapper Peak Identification in Ion mobility Spectrometry I. What is MIMA? MIMA is a software package for mapping mass-spectrometric (MS) data to corresponding ion-mobility spectrometer
More informationMRMPROBS tutorial. Hiroshi Tsugawa RIKEN Center for Sustainable Resource Science MRMPROBS screenshot
MRMPROBS tutorial Edited in 2016/11/16 Introduction MRMPROBS is launched as a universal program for targeted metabolomics using not only multiple reaction monitoring (MRM)- or selected reaction monitoring
More informationGetting Started Manual
Diablo 5000A RTGA Getting Started Manual By Diablo Analytical, Inc. Notices Diablo Analytical, Inc. 2007-2014, All rights reserved. No part of this manual may be reproduced in any form or by any means
More informationRelease Notes. Analyst Software with Hotfixes to February 2011
Release Notes Analyst 1.5.2 Software with Hotfixes to February 2011 February 2011 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment.
More informationRelease Note for Agilent LC and CE Drivers Revision A SR1
Release Note for Agilent LC and CE Drivers Revision A.02.19 SR1 Introduction This release note provides important information for the release of Agilent LC and CE drivers A.02.19 SR1. Service Release A.02.19
More informationImpact Analysis for Software changes in OpenLAB CDS A.01.04
Impact Analysis for Software changes in OpenLAB CDS A.01.04 Document Information: Filename Product Identifier Product Revision Project Identifier Document Revision Impact_Analysis_OpenLAB_CDS_A0104 OpenLAB
More informationVersatile. Innovative. Customizable M CVAF Mercury Analyzer
Versatile Innovative Customizable CVAF Mercury Analyzer M-8000 The QuickTrace M-8000 Cold Vapor Atomic Fluorescence mercury analyzer (CVAF) is ideal for ultra-trace to sub-mg/l mercury quantitation. It
More informationShimadzu IMD-MS news For Sales Forces of Shimadzu LCMS No. MSnews42 September, 2010
Shimadzu IMD-MS news For Sales Forces of Shimadzu LCMS No. MSnews42 September, 2010 Release of Shimadzu Triple Quadrupole Mass Spectrometer LCMS-8030 and workstation software LabSolutions LCMS Ver. 5 This
More informationFusion AE LC Method Validation Module. S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA USA Phone: URL:
Fusion AE LC Method Validation Module S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA 95501 USA Phone: 707-441-0404 URL: www.smatrix.com Regulatory Statements and Expectations ICH Q2A The objective
More informationTrue Blue Performance
True Blue Performance Improved Data, Fewer Liner Changes, and Less Downtime Exceptionally inert Sky inlet liners with state-of-the-art deactivation improve trace-level analysis even with wool and now come
More informationREACH FOR MORE CHOICES IN LC ANALYSIS. FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20
REACH FOR MORE CHOICES IN LC ANALYSIS FLEXAR LC Systems HPLC and UHPLC Flexar LC / Flexar FX-20 LC SOLUTIONS FOR ALL YOUR APPLICATIONS 2 CHOOSE EXACTLY THE SYSTEM YOU NEED Whether you need conventional
More informationOpenLynx User's Guide
OpenLynx User s Guide OpenLynx User's Guide Version 4.0 Waters part No 715000405 Micromass Part No - 6666670 5 February, 2002 i OpenLynx User s Guide OpenLynx User s Guide The software described in this
More information