PULIZZI ENGINEERING, INC.

Size: px
Start display at page:

Download "PULIZZI ENGINEERING, INC."

Transcription

1 PULIZZI ENGINEERING, INC. INTELLIGENT POWER CONTROLLER IPC3601 IPC3602 PATENT PENDING OPERATION and APPLICATION MANUAL 3200 SOUTH SUSAN STREET SANTA ANA, CALIFORNIA (800) (605) FAX PULIZZI ENGINEERING INC. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 1 of 19

2 TABLE OF CONTENTS 1.0 DESCRIPTION 1.1 Introduction Definition of Terms Features Operating Specifications 5 Electrical 5 Spike & Surge Suppression 5 Mechanical and Environmental Front and Rear Panel Features Optional Accessories 9 Power Cords, Brackets, Serial Cables OPERATION 2.1 Setup Equipment Location AC Power Connection Connecting The IPC34XX To The RS-232 Port Of The PC Network Connection ( -NET versions only) Interconnect Cables Standard RS232 Cables Null Modem Cable Network (RJ45) Cable 2.3 Communicating With The IPC34XX Addressing and Control Commands Web-Browser Controller Interface TROUBLESHOOTING TERMS AND CONDITIONS 19 F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 2 of 19

3 1.0 DESCRIPTION 1.1 Introduction The Pulizzi Engineering Inc. Model IPC 36XX is an Intelligent Power Controller providing distribution of AC power to controlled devices. The IPC36XX series is designed to provide the user with high quality, yet simplified power control of remote equipment. The IPC 36XX series is an AC-line power distribution controller providing remote control of up to 8 individual AC line receptacles. Process Control/Automation: With a computer connected to a network of IPCs, users have a complete process control system at a very reasonable cost. The IPC can be used to control systems such as conveyor lines, factory processes, robotics, TV/CATV antenna head-end systems, pipeline valves, pumping stations, computers, peripherals, drives, printers, communications equipment, environmental equipment, refrigerators, medical equipment, and on and on. Remote Reboot: The IPC36XX is also designed as a valuable tool for network managers to avoid downtime and save both time and money by preventing costly site visits to reboot locked-up computers and networking equipment. All IPC36XX series can be controlled via Serial Port (Text Interface) local terminal, Telnet TCP/IP, Web Browser (TCP/IP) or Simple Network Management Protocol (SNMP). The operator can enable or disable these interfaces except for the serial interface as needed. If further information or assistance is required, a factory representative can be contacted at: PULIZZI ENGINEERING, INC South Susan Street, Santa Ana, CA Voice: (800) Fax: (605) sales@pulizzi.com F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 3 of 19

4 1.2 Definition of Terms ETHERNET: An IEEE standard, for PC/AT networking, using baseband contention access over coaxial cable and twisted-pair wires. OUTLET: An AC power receptacle. PORT: In this context, a port will refer to an addressable serial or parallel PC/AT port. PULIZZI GUI INTERFACE: Graphical User Interface used to control the IPC34XX. RS-232: Type of standard protocol for serial communications. Standard includes such specifications as voltage and pin configurations for communications functions. Transmission distance limited to 25. RJ-11: Type of connector used on the IPC36XX series for serial communications RJ-45: Type of connector used on the IPC36XX for Ethernet Communications such as TCP/IP and SNMP TELNET: Communication protocol that uses port 23 (typically) to communicate to a network device. Most Terminal Emulators allow for a Telnet connection. Telnet is also an application that can be launched from DOS by typing TELNET. TERMINAL EMULATION PROGRAM: Serial communications program such as PROCOMM PLUS, PC Anywhere, or WINDOW S Hyperterminal which permit your personal computer or workstation to communicate with another computer or network as if it were a specific type of terminal directly connected to that computer or network WEB BROWSER: A graphical interface between a user and a server machine supporting Hyper Text Transfer Protocol (HTTP). The IPC36xx requires that the Web Browser support 64bit encrypted log-in capabilities. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 4 of 19

5 1.3 Features Web Browser User Interface Ethernet, TCP/IP RS-232 Communication Port for Serial control or modem connection 1 Unit High 19 Rack Mount Multi-position detachable mounting brackets Vertical mounting brackets available separately EMI/RFI Filtering (Some models) Spike/Surge Suppression Circuit Breaker Individually Addressable Password Protection User Defined Power Up/down Sequence Auto-Event Monitor Of Receptacles Data-Transfer Front Panel Indicator One Year Warranty On Workmanship And Material 2.4 Operating Specifications Electrical Specifications: SPECIFICATIONS: IPC3601 IPC3602 IPC3601-F Voltage Input/Output (50/60Hz): 120V~ or 240V~ 120V~ 240V~ Current Input: 120V~ or 240V~ 20A 30A Current Output De-rated: 16A 16A 24A Full Load VOLT-AMP De-rated: 120V~ or 240V~ 1920VA 2880VA Outlets (rear panel): IEC 320 Type C13 NEMA 5-15R IEC 320 Type C13 Circuit Breaker: 20A 20A 15/15A EMI/RFI Filter: 20A 20A NA Power Input: IEC 60320(C20 Type) IEC 60320(C20 Type) NEMA L6-30P plug Cable/Plug: Order Separately Order Separately 9 foot, 10/3 Cable Spike/Surge Suppression: The IPC34XX utilize 275V metal oxide varistor (MOV) and TVS Line to Neutral. Response time is approximately 50 nanoseconds. Exceeds recommended specifications for High Exposure Areas per ANSI/IEEE C , Class B. CAUTION: If the maximum voltage across the MOVs (reference to ground) is exceeded according to table 1. below, they will immediately fail. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 5 of 19

6 Table 1. MOV Ratings: MOV SPECIFICATIONS Continuous AC Voltage 270VAC Continuous DC Voltage 360VDC Maximum DC Leakage 200µA Low Varistor Voltage Limit 389VDC High Varistor Voltage Limit 453VDC Nominal Varistor Voltage 424VDC Current For Varistor Voltage 1mA Maximum Clamp Voltage 8x20µs 680V Maximum Clamp Voltage Test Current 100A Peak Current Rating (1 Pulse) 8x20µs 10000A Peak Current Rating (2 Pulse) 8x20µs 6500A Energy Rating (10x100µs) 325J Energy Rating (8x20µs) J Capacitance 970pf Impulse Response Time 50ns Table 2. Filter Specifications: EMI/RFI FILTERING Rated Voltage/Current: 125V/20A UL and CSA 250V/16A UL, CSA and VDE Operating Frequency: 50/60 Hz. Hi-pot rating 1 minute: 2250 VDC Line-Ground 1450 VDC Line-Line Maximum Leakage Current (each line-ground):.5 250V~ 50Hz UL #E72928, CSA #LR97784, VDE # COMMON MODE INSERTION LOSS (Line to Ground in 50ohm circuit) Mhz db DIFFERENTIAL MODE INSERTION LOSS ( Line to Line in 50ohm circuit) Mhz db Mechanical and Environmental Specifications: Width: 17.5 (Standard 19.0 rack mount) Height: 1.72 (1U rack space) Depth: 9.5 Approximate Shipping Weight: 19 lbs. (IPC3601-F is 27 lbs.) Operating Temperature Range: 0 to 50 C Storage Temperature Range: -40 to 65 C Operating Humidity Range: 0 to 95% RH Storage Humidity Range: 0 to 95% RH Power Usage (Control Circuitry) 120 watts max Mounting: Standard 19, EIA Rack Mount, Adjustable Mounting Brackets Chassis: 16 gauge steel, color black Front Panel: 10 indicator lights (Power, Data, 1 per outlet) and breaker Adjustable Mounting Options Front Flush Front Recessed Center Mount Rear Flush F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 6 of 19

7 1.5 Front and Rear Panel Features Intelligent Power Controller Model IPC36XX Front Panel 1. DETACHABLE MOUNTING BRACKETS Can be positioned for front/rear, flush/recessed, or center rack mounting. Vertical mounting brackets also available, see accessories. 2. DATA LED Indicates data traffic between the IPC and controlling computer. 3. (8) LED INDICATORS Shows individual outlet status. 4. POWER ON LAMP INDICATOR Illuminated when AC power is available at inlet and circuit breaker is ON. 5. MAIN POWER RESETTABLE CIRCUIT BREAKER 20A Models use a Thermal breaker, push to reset. 30A Models use a UL489 branch list circuit breaker that may be toggled on or off IPC a Rear Panel IPC (8) NEMA 5-15R RECEPTACLES Individually controllable AC outlets. a. (8) IEC C13 RECEPTACLES 2. ETHERNET CONNECTOR Network connection ( NET versions only). 3. RJ11 SERIAL INTERFACE CONNECTOR Connector for RS-232 from PC/AT to IPC36XX (Labeled J10) 4. Power Input 20A Models use an IEC C20 power inlet (Power cables sold separately). 30A Models use an attached power cable with appropriated plug. 5. GROUND chassis mounted nut for ground connection. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 7 of 19

8 1.6 Optional Accessories Power Cords C19 to Bare Wire (Pigtail) 8 foot, 1.5mm/3 Harmonized cable C19 to Bare Wire (Pigtail) 8 foot, 12/3 SJT cable NEMA 5-15P to C19 (125V, 15A) Straight Blade 8 foot 14/3 SJT cable NEMA 5-20P to C19 (125V, 20A) Straight Blade 8 foot 12/3 SJT cable NEMA 6-15P to C19 (250V, 15A) Straight Blade 8 foot 14/3 SJT cable NEMA 6-20P to C19 (250V, 20A) Straight Blade 8 foot 12/3 SJT cable NEMA L5-15P to C19 (125V, 15A) Twistlock 8 foot 14/3 SJT cable NEMA L5-20P to C19 (125V, 20A) Twistlock 8 foot 12/3 SJT cable NEMA L6-15P to C19 (250V, 15A) Twistlock 8 foot 14/3 SJT cable F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 8 of 19

9 NEMA L6-20P to C19 (250V, 20A) Twistlock 8', 12/3 SJT cable C20 Male to C19 (20 AMP) 8 foot 12/3 SJT cable CEE7-7 to C19 (250V, 16A) EUROPE 2.5M, 1.5mm/3 Harmonized cable BS546A to C19 (250V, 15A) BRITISH 2.5M, 1.5mm/3 Harmonized cable AS/NZS 3112 to C19 (250V, 15A) AUSTRALIAN 2.5M, 1.5mm/3 Harmonized cable SI32 to C19 (250V, 16A) ISRAELI 2.5M, 1.5mm/3 Harmonized cable CEI23-16 to C19 (250V, 16A) ITALIAN 2.5M, 1.5mm/3 Harmonized cable IEC 60320, 8' cord, C14 to C13 IEC 60320, 6' cord, C14 to C13 IEC 60320, 4' cord, C14 to C13 IEC 60320, 2' cord, C14 to C13 Serial DB9 Female to DB9 Female Straight through cable for direct serial connection, 6 feet long Vertical mount bracket, 2 required F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 9 of 19

10 2.0 OPERATION 2.1 Setup Equipment Location The Pulizzi Engineering, Inc. Intelligent Power Controller Model IPC36XX is housed in a 19 steel chassis intended for mounting in a cabinet or rack that accepts standard EIA 19 wide spacing. The power controller requires 1.75 (1U) of vertical mounting space and extends approx. 9.5 into the mounting rack of the cabinet. For convenience, the power controller should be mounted as close as possible to the units it controls. The unit is designed to support its own weight, ONLY. It is recommended that support brackets, which are available from most cabinet/rack manufacturers, be used. Vertical mounting brackets are also available separately that enable the IPC36XX to be mounted vertically in a rack, on a wall, or mounted under a desk or table top. Please see the accessories section AC Power Connection All wires, cables, cords, and connectors to be used with the IPC36XX should conform with the Uniform Safety Code of your local, state, and federal agencies. The IPC3601 should be powered by a standard VAC 50/60Hz line. The IPC3602 should be powered by a standard 120 VAC 50/60Hz. Do not defeat the third-wire ground as it is necessary for proper shielding, operation, and safety. An PEM nut is provided on the rear of the chassis for additional grounding. Input power cables are sold separately RS-232 Connection (Serial access/control) Hardware Configuration: To connect the IPC36XX to the COM port (RS-232) of the computer requires a serial female 9 pin DSUB to RJ11 Male cable (units are shipped with these cables). Connect one end to the PC/AT, sometimes labeled COM 1 or COM 2, and the other end to J10 connector labeled Serial on the rear panel of the IPC36XX. Software Configuration: The IPC36XX is designed to be used with Pulizzi s GUI terminal emulation software, down-loadable from the Pulizzi.com Web Page, or third party terminal emulation software such as PC-Anywhere, or Hyper Terminal. The standard settings in the terminal emulation software are: Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None The transfer protocol is ASCII. The COM port you address in software must correspond to the COM port you are connected to on the back of your computer. Please note that the user may configure the baud rate to be 9600, or Ethernet TCP/IP Network Connection (LAN or WAN access/control) F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 10 of 19

11 Hardware Configuration: Connect CAT-5 straight-through network cable to the RJ45 jack, J9 NET, found on the back panel of the IPC36XX. You may also connect the unit directly to a PC via a CAT-5 cross-over network cable. Please note in order to properly use the Ethernet connection the PC and the IPC36XX must be on the same class of network (IE computer address , Subnet Mask: ; IPC address , Subnet Mask ) IP Configuration: The IPC36XX will come from the factory with an IP address of and a subnet mask of Consult your network administrator for an IP address that is compatible with your network. You may assign an IP address to the IPC unit using one of the following methods. Serial Method: 1) Connect the IPC36XX to your computer via the RJ11 to DB9 serial cable. 2) Start your Terminal Emulation software configured to the settings in section ) Apply power to the IPC36XX unit 4) Wait for the Log In prompt (that will appear after 30 second self check) 5) Login to the unit using your user name and Password. The User Name is Admin and password is ipc by default, and is case sensitive. 6) Choose Main Menu option 3 (Unit Configuration), 2 (Net Work Settings). Enter in the settings that you require. 7) Once configuration settings have been made, go back to the main menu and choose option 6 (Soft Reboot) to restart the unit an apply changes. Ethernet (Telnet) Method: 1) Connect your IPC to your computer via a cross-over CAT-5 cable (Not provided). 2) Configure your computer to have a static IP address of with a subnet mask of (Consult your operating system instructions on how to complete this task). 3) Apply power to the IPC36XX and wait approximately 40 seconds for the unit to start. 4) Open a Telnet session to the unit at ) Login to the unit using your user name and Password. The User Name is Admin and password is ipc by default, and is case sensitive. 6) Choose Main Menu option 3 (Unit Configuration), 2 (Net Work Settings). Enter in the settings that you require. 7) Go back to the main menu and choose option 6 (Soft Reboot) to restart the unit an apply changes. 2.2 Interconnect Cables The IPC36XX ships with (1) 6 DB9 Female to RJ11 Male serial cable part number and F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 11 of 19

12 (1) 7 Strait-through RJ45 to RJ45 Serial Cable part number Serial Cable The IPC36XX series utilizes a RJ11 port for serial communications. To connect to a standard PC COM port the unit comes with a RJ11 to DB9 cable. The Pin-out of the cable is shown below. RJ11 Pin Direction DB9 Pin 1 N/C N/A 2 N/C N/A 3 TX OUT 2 RX IN 4 RX IN 3 TX Out 5 GND 5 GND 6 N/C N/A Network (RJ45) Cable A network cable is a CAT 5 type cable with RJ45 type connectors on each end of the cable. This cable is a straight through cable (1-1, 2-2, 3-3, etc.) A network cable is used for connecting the IPC36xx to your network port (hub or switch). 2.3 Communicating and Controlling the IPC36xx The IPC36XX has several interfaces available to use. These include a Text-Based serial control interface for use with a PC, Telnet (TCP/IP) text-based interface, Web Browser (TCP/IP) Graphical Interface, and Simple Network Management Protocol (SNMP). The user may enable or disable any interface except for the serial communications which are always enabled. The IPC36XX will allow only (1) Text based interface to be open at a time (Serial or Telnet). If a session is already open it will not allow another user to open an additional session. The IPC36XX supports up to 12 users at once through the web browser interface. The unit can simultaneously support (1) Text Interface, (12) Web browser interfaces and SNMP control Serial Control (Text Commands) After making a connection to the IPC36XX via terminal emulation software, press enter. The unit will prompt you for a User Name and Password (Default user name is Admin, and password is ipc ). Press the number of the menu item you wish to use. To go up a level from a menu simply press the (ESC) key. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 12 of 19

13 2.3.1 Telnet Control (Text Commands) Open a telnet session to the unit (default port 23) using your preferred telnet software. The unit will prompt you prompt you for a User Name and Password (Default user name is Admin, Default password is ipc ). Press the number of the menu item you wish to use. To go up a level from a menu simply type b followed by (Enter) Web Browser Control (Graphical Interface) In order to use the Web Browser interface you must have a browser that supports 64-bit security authentication. To use the Web Browser interface start the web browser, and go to the address where xxx.xxx.xxx.xxx is the IP address of the IPC36XX unit (IE. The Web Browser will prompt you for a User Name and Password (Default user name is Admin, Default password is ipc ). To end the session close the Web Browser of click the Log Off button from the side menu F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 13 of 19

14 2.4 IPC36XX Features Security Features a) Users - Up to (12) users (1 Admin + 11 users) - Each user can have a unique User Name / Password (Except Admin user name) - Changeable Admin Password - Admin can define which outlets user have control over - The 11 User s (non-admin) only have control to change / view their assigned outlets b) Interface Enable/Disable Options - Admin may enable or disable the Web Browser interface, SNMP interface, or Telnet interface as desired - Serial interface can not be disabled c) Web Browser Security - All users are authenticated using 64-bit encrypted User Name / Password - Only Admin has access to full set of menu options, users are limited to outlet control of specified outlets, outlet status of specified outlets and log off d) Telnet / Serial Security (Text Interfaces) - Login user name and passwords are required - Users will automatically be logged off after a specified period of inactivity (240 seconds by default) - Only Admin has access to full set of menu options, users are limited to outlet control of specified outlets, outlet status of specified outlets and log off e) Simple Network Management Protocol (SNMP) Security - SNMP may be enabled of disabled - SNMP supports a public community password and private community password (v 2.0) Outlet Control and Options a) Outlet Control - Individual outlets may be turned on, turned off, or rebooted - All outlets (Global Control) may simultaneously be turned, off, or rebooted b) Outlet Naming - Outlets may each be named with a unique name (IE. Server). - Each outlet may have a URL assigned to it. This can be used for quick accesses to the device. For Example a link to the Admin interface of a Switch. c) Outlet Grouping - Admin may create up to (8) Groups of outlets containing any combination of individual outlets - Each group of outlets may have a custom name (IE. Server Group) - Control function may be simultaneously applied to that group of outlets (IE. All On, All Off, Reboot) d) Outlet Sequencing - A Power Up / Power Down sequence of the outlet may be defined by Admin - Delay is specified in seconds - Power Down will follow the Power Up sequence in reverse order. For Example if the outlets are set to power up in the following sequence: Outlet 1 1 Second, Outlet 2 2 Seconds Outlet 8 8 Seconds. Then when the PDU is asked to sequence off the outlets they will shut off in the following order: Outlet 8 0 Seconds, Outlet 7 1 Second Outlet 1 8 Seconds. e) Outlet Power-On State F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 14 of 19

15 - Outlets may be power on in previous state (before power loss) - Outlets power up according to user defined power Up Sequence (Factory Default) - If All outlets are to remain off the then power Up/Down sequence times for those outlets that are to stay off should be set to 0 seconds and the power on-state set to Sequence f) Outlet Auto Scheduling - Admin may specify outlet scheduling for individual outlets or outlet groups - Outlet scheduling lets the user specify whether and event is to happen Daily or weekly at a specified time - Options for Auto Schedule Action include Outlet / Group On, Outlet / Group Off and Outlet / Group Reboot. g) Outlet Security - Admin has control over all outlets and group - Users have limited control over selected outlets as defined and no control of groups Alerts and Logs a) Events and Alert Options to send - The IPC36XX stores events and alerts such as when a user logs in, log in failures, when an outlet status is changed, ect. - These logs can automatically be ed to up to 4 separate s using a POP3 server - Events include: User Login/Logout, Failed Login Attempt, Outlet Activity and System on/off. b) Mail Server - To use the features you must have a POP3 server that the unit can accesses - The POP3 server must be specified by the IP address of the server (IE ) c) Addresses - There are (2) addresses allowed for logs to be sent to and (2) addresses allowed for Alerts to be sent to. - Different types of events may be specified for each the Logs and Alerts - Events include: User Login/Logout, Failed Login Attempt, Outlet Activity and System on/off. d) Log Schedule - Logs can be specified to be sent Daily, Weekly or when full - User can specify what day and or time the log is sent if Daily or Weekly is set Interface Configuration Options a) TCP/IP Settings - TCP/IP options include IP Address, Subnet Mask, and Default Gateway - The IP address should be set to the same class as your network. For example of the subnet is the the first three numbers of the units IP address must be the same as the rest of the devices on your network. (IE other devices in your network start with xxx, so must the IPC36xx) - Set the Default Gateway if you are using a NAT (Network Address Translation) device and want to have accesses to the IPC from the WAN (World Area Network) outside of your LAN (Local Area Network). If you do not plan to accesses the device for the WAN or the unit is directly connected to the WAN then this does not need to be set. b) Serial Settings - The Serial Baud rate may be changed from the default rate of 9600 to or F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 15 of 19

16 Keyboard inactivity time-out may be changed so that a the user is automatically logged off after a specified time (240 seconds by default) c) Telnet Settings - Telnet can be enabled or disabled as needed - The telnet port number can also be changed from the default port 23. If the telnet port is change then when using telnet with the unit you will need to specify the port number. For Example Telnet Keyboard inactivity time-out may be changed so that a the user is automatically logged off after a specified time (240 seconds by default) d) WEB Settings - Web Browser Accesses may be enabled or disabled as needed - The port number may be changed from the default port of 80. If the default port is changed then when controlling the IPC in your Web Browser you will need to go to the address of where xxx.xxx.xxx.xxx is the IP Address of the unit and port is the port number you have specified. For example - Inactivity time-out may be changed so that a the user is automatically logged off after a specified time (240 seconds by default) e) Simple Network Management Protocol (SNMP) Settings - SNMP Options Include o Public Community Name (public is the default) o Private Community Name (private is the default) o Trap Community Name (public is the default o Public Community Password o Private Community Password o Trap IP Address (IP Address traps should be sent to) o SNMP Enable / Disable o Trap User Login/Logout o Trap Failed Login Attempt o Trap Outlet Activity o Trap System On/Off Unit Configuration a) Unit Name b) Admin Password c) Unit Time & Date d) Keyboard Timeout F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 16 of 19

17 3.0 TROUBLESHOOTING This section not available at the time of printing. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 17 of 19

18 4. TERMS AND CONDITIONS 1. CHANGES: Pulizzi Engineering, Inc. (PEI) reserves the right to make specifications and price changes on standard catalog items, without prior notice. Please consult the factory for current product and price information. 2. PRICING A. Quotations are firm for a period of thirty (30) days unless otherwise specified. B. Prices will remain firm for all scheduled releases. Unscheduled releases may be subject to pricing changes. C. Pulizzi Engineering does not discount back product already shipped when purchase order quantities are increased. D. A bill-back will apply on product previously shipped, if committed quantities are not shipped during the period of the contract, or purchase order. The amount billed will be equal to the difference in discount between the actual quantity shipped and that quantity to which the contract/order was committed. E. Pulizzi Engineering, Inc. reserves the right to enforce a $50.00 minimum on all orders. 3. SHIPMENT SCHEDULE: Change Orders, defined as increases, decreases or reschedule requests pertaining either the ship date or quantity, require a written thirty (30) day notice, prior to the confirmed scheduled ship date for standard catalog items. Custom item rescheduling periods vary by model. Please consult the factory. There is a $50.00 per purchase order change required on the updated purchase order. 4. DELIVERY: Delivery will be FOB ORIGIN (PEI plant Santa Ana, CA). Purchaser will be responsible for all subsequent charges. All shipments are to be made FREIGHT COLLECT on client specified carrier and account number. If requested and stated on clients purchase order, freight can be prepaid and added to invoice with prior approval from Pulizzi Engineering. Purchase order must also state the carrier to be used. Pulizzi Engineering, Inc. will ship uninsured. Purchaser hereby grants Pulizzi Engineering a security interest in the products and in any proceeds (including accounts receivable) as security for its obligations hereunder, and will execute any documents required to protect this security interest. 5. DAMAGED SHIPMENTS: All outgoing shipments are FOB ORIGIN (PEI plant Santa Ana, CA). Therefore. all damage claims must be collected by the consignee. Do not return damaged merchandise prior to establishing a claim. If damage is suspected, notify delivery carrier immediately. It is necessary to have the entire shipment inspected by carrier, regardless of the condition of containers. When a claim has been established and a RMA is granted, the damaged material may be returned for repair or replacement. Invoice for repair charges may then be collected by the customer from the carrier. DO NOT DESTROY PACKING MATERIAL OR BOXES UNTIL CARRIER S AGENT HAS EXAMINED THEM. 6. CANCELLATION: All orders are subject to cancellation charges and/or restocking fees. All applicable partial Non-Recurring Engineering (NRE) fees and/or set up fees will be invoiced and are payable in full upon order cancellation. Special orders for items and/or quantities not normally stocked are non-cancelable and nonreturnable. 7. PAYMENT: Terms are Net thirty (30) days from invoice date for U.S. operating companies only, on approved credit, unless otherwise stated. All others shall be via money wire transfer prior to shipment. Accounts are reviewed periodically and terms are subject to change as a result of this review, without notice. 8. TAXES: Prices are exclusive of, and purchaser is responsible for, all sales, use and like taxes. 9. WARRANTY A. Products are warranted against defects in workmanship and materials for a period of one (1) year from the date of shipment. Extended warranties are available, at time of purchase only, at the rate of 15% of the product price per each additional 12 month period. B. Pulizzi Engineering s sole responsibility under this warranty shall be to either repair or replace, at its option, any component which fails during the applicable warranty period. A failure shall only be due to faulty workmanship or material, or both. C. Exclusions: 1. Metal Oxide Varistors (MOV s) are protection devices which are intended to self-destruct in cases of extreme voltage spikes or surges, and repairs relative to these devices are not covered under this warranty. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 18 of 19

19 2. External physical damage (not shipping related) to any units NOT reported within thirty (30) days of receipt of the product. 3. Shipping damage (See FOB under [4] DELIVERY and [5] DAMAGED SHIPMENTS.). 4. Test failure for tests not authorized by Pulizzi Engineering. Test procedures are available upon request. D. Pulizzi Engineering will honor the warranty at a Pulizzi Engineering repair facility in the United States as specified by Pulizzi Engineering, provided all procedures are followed. Purchaser will return units(s) at its own expense and only with prior authorization from the factory. Instructions will be given by an authorized factory representative at the time an inquiry is made. Transportation charges will be paid by Pulizzi Engineering to all US destinations (including Alaska and Hawaii) via surface freight or other method (excluding Air Freight). Expedite delivery charges are to be paid by the customer. E. If Pulizzi Engineering determines that units returned are not defective under the terms of the warranty, customer will be responsible for all evaluation, test, repair and handling charges or $90.00, whichever is greater, as well as all incoming and outgoing freight charges. F. EXCEPT FOR THE EXPRESS WARRANTIES STATED HEREIN, PULIZZI ENGINEERING DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HEREUNDER, INCLUDING, WITHOUT LIMITATION, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS; and the stated express warranties are in lieu of all obligations or liabilities connected with the performance of the products. 10. RETURN MATERIAL AUTHORIZATION (RMA) POLICY: In order to return material to the manufacturer, a Return Material Authorization (RMA) number is required as well as a customer assigned purchase order number in order to cover the costs of the RMA. This PO shall authorize either: (A) $90.00 per unit fee for no trouble found (NTF) on warranty units or (B) 50% of the purchase price or $ which ever is greater, for repair of non-warranty units. If the repair cost turns out to be greater than this estimate, customer will be notified prior to repairing unit. Otherwise, customer will be billed actual repair cost, not exceeding item (B) above. The RMA number must appear on all shipping labels and packing slips. Failure to do so will result in refusal of shipment. A written description of the fault is also required. The more detailed the failure description, the faster the repair and return will be. Please refer to the WARRANTY section D for shipping procedures. Shipments sent FREIGHT COLLECT will be refused. NOTE: Every effort will be made to correct problems over the phone before a RMA is issued. RMA numbers are good for 30 days only. If shipment is not received by Pulizzi Engineering, Inc. within 30 days of issue, please call for a new RMA number if still required. 11. EVALUATION UNITS: All Test and Evaluation units will be invoiced like a normal shipment, except the terms will be Net sixty (60) days. If the unit is returned within the thirty (30) day test and evaluation period, and is received in a like new condition, in the original packaging, a full credit, minus the shipping charges and a $75.00 restocking fee, will be applied to the customer s account. The customer is responsible for ALL shipping cost. 12. EXPORT: Regardless of any disclosure made by Purchaser to Pulizzi Engineering, Inc., of an ultimate destination of the products, purchaser will not export, either directly or indirectly, any products or systems incorporating such product without obtaining a license from the United States government, as required. 13. GENERAL PROVISIONS: In the act of accepting a purchaser s order, Pulizzi Engineering will form an agreement subject only to these TERMS and CONDITIONS. These TERMS and CONDITIONS will supersede any previous communications, representations, or agreements by either party whether verbal or written, including any Terms and Conditions on Purchaser s order. Any modification to these TERMS and CONDITIONS must be in writing and signed by authorized representatives of Pulizzi Engineering, Inc. and Purchaser. This agreement is governed by and construed under the laws of the State of California. 14. PROPRIETARY DESIGN: Pulizzi Engineering, Inc. reserves all patent, copyright, proprietary design, manufacturing, reproduction, and sale rights to all products that the company manufactures. The copying of any products or documents without the written consent of Pulizzi Engineering, Inc. is a violation of federal and state laws liabilities connected with the performance of the products. 15. EXCUSABLE DELAY: A mutually agreed-upon delivery date extension shall be negotiated in the event of any delay in the delivery of the products services by Pulizzi Engineering, Inc. which is caused by, but not limited to, earthquake, acts or omissions of the buyer, riot, acts of God, civil strike, unsuitable weather, labor dispute, transportation delays, energy shortage, government or military authorities or any event beyond the reasonable control of Pulizzi Engineering, Inc. F:\Mpulizzi\Manuals\IPC3600_Full_Manual_Rev_A.doc Page 19 of 19

PULIZZI ENGINEERING, INC.

PULIZZI ENGINEERING, INC. PULIZZI ENGINEERING, INC. INTELLIGENT POWER CONTROLLER IPC3401 IPC3401-NET IPC3402 IPC3402-NET PATENT NO. 5,923,103 OPERATION and APPLICATION MANUAL 3200 SOUTH SUSAN STREET SANTA ANA, CALIFORNIA 92704-6865

More information

Three Phase Systems-International PC302-I/MTD

Three Phase Systems-International PC302-I/MTD Three Phase Systems-International PC302-I/MTD Enclosure Power Distribution Units (epdu ) sales@pulizzi.com 800-870-2248 Fax: 605-334-4999 Front RACK MOUNTED 19 x 3.4 (2U) x 8.5 with recess mounting Approximate

More information

Single Phase Systems-North American PC125/PC420 Series

Single Phase Systems-North American PC125/PC420 Series Single Phase Systems-North American PC125/PC420 Series Enclosure Power Distribution Units (epdu ) PC125-C Front RACK MOUNTED 19 x 3.4 (2U) x 8.5. Approximate shipping weight: 19 lbs. (12) NEMA OUTLETS

More information

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items: Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this

More information

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing MODEL NUMBER: IBAR12 Highlights 12 NEMA 5-15R outlets in exclusive isolated filter

More information

INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N

INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N IF FOR SOME REASON YOU HAVE TO RETURN THIS ITEM TO THE FACTORY FOR ANY SERVICE OR REPAIR, YOU MUST CONTACT CUSTOMER SERVICE FOR AN RMA NUMBER AT (585)

More information

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2. Page 1 of 5 Model 282 Total Interface Isolation Module Reference Manual 0315-0169 Rev. A Print 08.01.01 1.0 General Description Table of Contents 2.0 Specifications 2.1 Interface 2.2 Connectors 2.3 Isolation

More information

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR6 Highlights 6 NEMA 5-15R outlets in exclusive isolated filter banks Network-grade

More information

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual Document No: WD102681-1 Document Revision Date: April, 2011 HydroLynx Systems, Inc. Model 50386D Decoder Receiving and Unpacking Carefully

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1

CMR Quick Start Guide. CMR-8500 DVB IP Encapsulator. Part Number MN-CMR68500-QSG REV. 1 CMR-8500 Quick Start Guide CMR-8500 DVB IP Encapsulator Part Number MN-CMR68500-QSG REV. 1 Copyright Comtech EF Data, 2008. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street,

More information

pakedgedevice&software inc.

pakedgedevice&software inc. pakedgedevice&software inc. P20/P20E Boot Sequence Power Distribution Unit with Remote Power Cycling and Monitoring User Guide Version 1.0 Table of Contents Introduction... 1 P20 Package... 2 Installation...

More information

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers

More information

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing

Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Light Gray Housing Protect It! 7-Outlet Surge Protector, 6 ft. Cord, 1080 Joules, Diagnostic LED, Housing MODEL NUMBER: STRIKER Highlights 7 NEMA 5-15R outlets one designed for a bulky transformer 1080-joule surge protection

More information

Ethernet Power Controller II USER S GUIDE Walsh Avenue, Santa Clara, CA Tel: (408) , Fax: (408)

Ethernet Power Controller II USER S GUIDE Walsh Avenue, Santa Clara, CA Tel: (408) , Fax: (408) USER S GUIDE 2695 Walsh Avenue, Santa Clara, CA 95051 Tel: (408) 330-5599, Fax: (408) 541-8459 Congratulations on your purchase. The is a rack mount power switch used for remote control, automatic reboot,

More information

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR4ULTRA Highlights 4 NEMA 5-15R outlets in exclusive isolated filter banks

More information

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal MODEL NUMBER: ISOTEL4ULTRA Highlights 4 NEMA 5-15R outlets in exclusive isolated filter

More information

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE MiT MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE OF A-LMS 24 Architectural Lighting Management System Part number A000230-xxx Manual Version 1.0 MOVING image TECHNOLOGIES,

More information

Data-Tronix DT-HDVD-M2MLT-ENC DT-HDVD-M2MLT-RX. H.264 HDMI video Encoder and. H.264 HDMI video Decoder. User Manual. 15 Version: V1.0.

Data-Tronix DT-HDVD-M2MLT-ENC DT-HDVD-M2MLT-RX. H.264 HDMI video Encoder and. H.264 HDMI video Decoder. User Manual. 15 Version: V1.0. Warranty Terms and Conditions DATATRONIX 1-Year Limited Warranty DATATRONIX. (the "Company") warrants to the Original Purchaser that the item purchased is free from defects in workmanship or material under

More information

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs

LBC-PSW52. Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs LBC-PSW52 Link Bridge TM Presentation Scaling Switch with 5 Inputs and Two Mirrored Outputs BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

ANI-RPS Outlet Remote IP Control Total Current Monitoring & Temperature - 15Amp INSTRUCTION MANUAL

ANI-RPS Outlet Remote IP Control Total Current Monitoring & Temperature - 15Amp INSTRUCTION MANUAL ANI-RPS08-15 8 Outlet Remote IP Control Total Current Monitoring & Temperature - 15Amp INSTRUCTION MANUAL 122 Rose Ln., Suite 303, Frisco, Texas 75036 Email: sales@a-neutronics.com A-Neutronics.com SAFETY

More information

VIP-812A DUAL NETWORKED STATION PORT

VIP-812A DUAL NETWORKED STATION PORT ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS

More information

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Tel/Coax/Modem, Metal MODEL NUMBER: ISOBAR6DBS Highlights 6 NEMA 5-15R outlets in exclusive isolated filter

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing

Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Black Housing Protect It! 10-Outlet Surge Protector, 8 ft. Cord with Right-Angle Plug, 2395 Joules, Tel/DSL Protection, Housing MODEL NUMBER: TLP1008TEL Highlights 10 NEMA 5-15R outlets, including 4 for bulky transformers

More information

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to

More information

All the registered trademarks referred to this manual are belonging to their respective companies.

All the registered trademarks referred to this manual are belonging to their respective companies. MiniDE User Manual COPYRIGHT and TRADEMARK All rights reserved by APANTA LCC, Porland, Oregon, USA. No part of this document may be reproduced in any form or by any means without written permission from

More information

MFJ ENTERPRISES, INC.

MFJ ENTERPRISES, INC. Model MFJ-1163 INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment MFJ ENTERPRISES, INC. 300 Industrial Park Road Starkville, MS 39759 USA Tel: 662-323-5869 Fax: 662-323-6551 VERSION

More information

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing MODEL NUMBER: ISOBAR8ULTRA Highlights 8 NEMA 5-15R outlets in exclusive isolated filter banks

More information

Leased-Line Extenders over IP

Leased-Line Extenders over IP SmartNode 2290 Series Leased-Line Extenders over IP Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

V-9908 MESSAGE/PAGE PANEL

V-9908 MESSAGE/PAGE PANEL Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides

More information

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.

More information

Data Broadcast Switch

Data Broadcast Switch Data Broadcast TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS... SECTION - INTERFACE SIGNALS AND CABLING...

More information

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller ESCORT MEMORY SYSTEMS COBALT C0405-232-01 RFID CONTROLLER High Frequency Passive Radio Frequency Identification Controller INSTALLATION GUIDE How to Install and Configure Escort Memory Systems Cobalt C0405-232-01

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual INC PBB-24 Plus Programmable Button Box Firmware version v 3.19 Manual Update: 06/10/2008 Due to the dynamic nature of product design, the information contained in this

More information

NAS LCP CONTROLLER WITH PANEL FACEPLATE

NAS LCP CONTROLLER WITH PANEL FACEPLATE NAS LCP CONTROLLER WITH PANEL FACEPLATE OPERATIONS AND MAINTENANCE MANUAL North American Signal Systems LLC 605 NW 53 rd Ave. Suite A-17 Gainesville, FL 32609 Phone: (800) 201-5566 www.nasignal.com NAS

More information

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web:

USER MANUAL. DV-HAS HDMI Audio Separator LIT Bergen Boulevard, Woodland Park, NJ Tel FAX Web: USER MANUAL DV-HAS HDMI Audio Separator 244 Bergen Boulevard, Woodland Park, NJ 07424 Tel 973-785-4347 FAX 973-785-3318 Web: www.fsrinc.com LIT1460 Proprietary Information All information in this manual

More information

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols

Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols USER MANUAL Industrial Ethernet Ethernet to Serial Gateways Ethernet to Serial Converters for Modbus, Red lion and other protocols Contents at a Glance: Section 1 General Information RM-PS-024-01F 3 Section

More information

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control

Installation Manual SM-RS Port RS232 Router with optional TCP/IP control Installation Manual SM-RS232 16-Port RS232 Router with optional TCP/IP control Control up to 16 RS232 compliant devices up to 50 feet away over UTP or from anywhere via TCP/IP (optional) What s in the

More information

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing MODEL NUMBER: ULTRAFAX Highlights 2 NEMA 5-15R surge-protected outlets 1410-joule surge

More information

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7 ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...10

More information

NETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL

NETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL NETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL Contents Chapter 1 Introduction... 1 Chapter 2 Mounting the Switch... 2 2.1 Environmental Requirements... 2 2.2 Installation Instruction... 2 2.3 Connect

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection

Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection MODEL NUMBER: AV810 Highlights 8 outlets / 10-ft. cord with space saving right angle plug 3240 joule rating

More information

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors TC3705 10/100Base-T Ethernet Fiber Optic Switch User's Manual 1. Features 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors 1 Fiber Optic 100Base-FX Port MDI/MDIX Auto Detection

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

Power Supply (48Vdc, 2.5A)

Power Supply (48Vdc, 2.5A) Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.

More information

BAYTECH REMOTE POWER CONTROL UNIT FOR MODELS RPC-2 RPC-2A RPC-2 MD01 RPC3-15

BAYTECH REMOTE POWER CONTROL UNIT FOR MODELS RPC-2 RPC-2A RPC-2 MD01 RPC3-15 OWNER S MANUAL BAYTECH REMOTE POWER CONTROL UNIT FOR MODELS RPC-2 RPC-2A RPC-2 MD01 RPC3-15 Amp RPC3-20 Amp RPC-3A RPC-4 RPC-5 RPC-7 RPC-21 BayTech Manual Publication #U140E125-05 January 2000 Copyright

More information

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack The NT1-220 Rack is designed to be used in conjunction with Tone Commander NT1U-220TC ISDN Network Terminations. A maximum of twelve NT1 units can be used in each rack. NT1-220 Rack Installation Instructions

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

XC300 VDSL Network Extender Owners Manual

XC300 VDSL Network Extender Owners Manual XC300 VDSL Network Extender Owners Manual Warranty GDI Communications LLC warrants to the original consumer purchaser that each of its hardware products, and all components thereof, will be free from defects

More information

T1/E1 Channelized Gigabit Router

T1/E1 Channelized Gigabit Router OnSite 2884 Channelized Gigabit Router Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial

More information

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control

Remote Control for Inverter RC-300. Owner's Manual. Please read this manual BEFORE operating your RC-300 Remote Control Remote Control for Inverter RC-300 Owner's Manual Please read this manual BEFORE operating your RC-300 Remote Control OWNER'S MANUAL Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 HOUSTON TX 77041-8943 VOICE (713) 973-6905 FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Zonit μats TM Users Guide μats1-lv Version 1.2

Zonit μats TM Users Guide μats1-lv Version 1.2 Zonit μats TM Users Guide μats1-lv Version 1.2 Table of Contents Product Overview...2 Pre-Installation Considerations...2 Product Features...3 Installation...4 Optional Accessories...4 μats TM Operational

More information

Installing and Managing the Switch

Installing and Managing the Switch CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4

More information

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure 550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure MODEL NUMBER: AV550SC Highlights 4 AC outlets (including 1 delayon outlet for router) Automatic recycle/reset

More information

HDTVMT User Manual

HDTVMT User Manual HDTVMT0808140 User Manual HDTV Supply, Inc. Contact: support@hdtvsupply.com 1 Thank you for purchasing this product. For optimum performance and safety, please read these instructions carefully before

More information

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

4300 WINDFERN RD #100 - HOUSTON TX VOICE (713) FAX (713) web:   IMPORTANT!!! 4300 WINDFERN RD #100 - HOUSTON TX 77041-8943 VOICE (713) 973-6905 - FAX (713) 973-9352 web: www.twrlighting.com IMPORTANT!!! PLEASE TAKE THE TIME TO FILL OUT THIS FORM COMPLETELY. FILE IT IN A SAFE PLACE.

More information

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

OPERATING AND SERVICE MANUAL. Universal Interface Device 47 OPERATING AND SERVICE MANUAL Universal Interface Device 47 MAGNA-POWER ELECTRONICS, INC. 39 ROYAL ROAD, FLEMINGTON, NJ 08822 May 24, 2012 SAFETY NOTICE Universal Interface Device 47 (UID46) connects

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after October 2014 Kernel Version: 6.15 Document Revision: 3 QuickServer

More information

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control

Remote Control for Inverter RC-200. Manual. Please read this manual before operating your RC-200 Remote Control Remote Control for Inverter RC-200 Owner's Manual Please read this manual before operating your RC-200 Remote Control Owner's Manual Index SECTION 1 Safety...3 SECTION 2 Description...3 SECTION 3 Layout

More information

Remote Refrigeration Control

Remote Refrigeration Control Remote Refrigeration Control Installation & Operation Bulletin No. H-IM-RRC June 2018 Part Number 25092901 Replaces H-IM-RRC (01/17) Remote Refrigeration Control Installation Start Up Troubleshooting Operation

More information

NT1B-300 Rack Installation Instructions

NT1B-300 Rack Installation Instructions The NT1B-300 Rack houses 24 Tone Commander NT1B-300TC ISDN Network Terminations in a 19 rack, 23 rack, or wall mount configuration. The rack is also compatible with Lucent NT1B-300 NT1s. The rack supplies

More information

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR

More information

MCS-Spectrum. Tactile Colorist Control Surface. Users Manual

MCS-Spectrum. Tactile Colorist Control Surface. Users Manual MCS-Spectrum Tactile Colorist Control Surface Users Manual MCS-Spectrum, MCS-3800, MCS-3400 and MCS-3000 are trademarks of JLCooper Electronics. All other brand names are the property of their respective

More information

Macon Plastics, Inc. Solvent Weld SCH 40/80 DWV

Macon Plastics, Inc. Solvent Weld SCH 40/80 DWV Catalog #210SDWV MP Macon Plastics, Inc. & DWV Fittings P R I C E L I S T Solvent Weld /80 DWV Effective Date: 02/02/15 Catalog : 210SDWV Revision: D Supercedes: 209SDWV Not sure if you have a current

More information

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection

Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection Eco-Surge 8-Outlet Surge Protector, 8-ft. Cord, 2880 Joules, Tel/Modem/Coax/Ethernet Protection MODEL NUMBER: AV88SATG Highlights 8 outlets / 8-ft. cord 2880 joule rating Auto/Manual switch offers GREEN

More information

BACnet Router Start-up Guide

BACnet Router Start-up Guide BACnet Router Start-up Guide BAS Router (BACnet Multi-Network Router) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after January 2015 Kernel Version: Application Version: Document

More information

Installation and Operation

Installation and Operation Installation and Operation G-Type Rack Power Filter G50NETB2 G50NETB-20A2 120 Vac 15 A 20 A General Information Product Features The APC AV G-Type G50NETB2 and G50NETB-20A2 Rack Power Filters protect high-performance

More information

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and

More information

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch 12 Omnitron Systems Technology, Inc. Omnitron Systems Technology, Inc. 1 FlexSwitch TM 600X 16/24 Port /0 -Sensing Dual Speed Ethernet Switch User s ual 27 Mauchly #201, Irvine, CA 92618 (949) 250-65 Fax:

More information

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285. SECTION 26 04 75 - SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Applicable provisions of the General Conditions, Supplementary General Conditions and Special Conditions shall govern work performed

More information

PARALLEL TO SERIAL INTERFACE & SERIAL CASH REGISTER INTERFACE & REGCOM NETWORKING

PARALLEL TO SERIAL INTERFACE & SERIAL CASH REGISTER INTERFACE & REGCOM NETWORKING P2RS-PRO PARALLEL TO SERIAL INTERFACE & SERIAL CASH REGISTER INTERFACE & REGCOM NETWORKING Operation Manual June 2010 Introduction The P2RS-Pro is a multi-functional POS / Cash Register Interface peripheral.

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER7TEL Highlights 7 outlets / 7-ft. cord 2520 joule rating Modem/fax surge protection $75,000

More information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information Grooved-type with Built-in Amplifier EZ-G CSM_EZ-G_DS_E_9_ with Grooved Design and Easy Settings Groove-type with groove width of 5 mm. Models are available with one or two light axes. Models are available

More information

SERVICE MANUAL MODEL SSW-321-X

SERVICE MANUAL MODEL SSW-321-X SSW-321-X-ISSUE 4.0 SERVICE MANUAL FOR MODEL SSW-321-X STAINLESS STEEL WALL TELEPHONE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street & Engineering Company Okeechobee,

More information

Switched Vertical PDU. User s Guide 1 IP CONTROLLED VPDU

Switched Vertical PDU. User s Guide 1 IP CONTROLLED VPDU Switched Vertical PDU User s Guide 1 Standard Features Congratulations on your purchase. The web power switch is a cost effective AC power switch for remote control and reboot. Web Interface The internal

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7 ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION... SECTION - SPECIFICATIONS... SECTION - INSTALLATION... SECTION - FRONT PANEL CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL 1 IMPORTANT SAFETY INSTRUCTION READ FIRST This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure-voltage

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

Vapor Monitor Interface Module

Vapor Monitor Interface Module Manual No: 577013-951 Revision: A Vapor Monitor Interface Module Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the

More information

600 SERIES. Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation. Reference Manual. Rev A. Version 2.6.0

600 SERIES. Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation. Reference Manual. Rev A. Version 2.6.0 Results You Can Count On Reference Manual 600 SERIES Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation Rev A Version 2.6.0 Date of Publication: 03/05/2019 Customer Care Warranty

More information

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6 CFS Family TITLE PAGE Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6 Part Number Model Description A70-00-5006

More information

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES

REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES REDUNDANT POWER SUPPLY SYSTEM FOR NETGEAR RPS CAPABLE ETHERNET SWITCHES MODEL NO. OPN300-48SN Single-Port 48V DC Output RPS System Manual Revision E May 2009 Optimal Power Supplies LLC www.optimal-power.com

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

User s Guide. POWERVAR Single Phase Power Conditioners

User s Guide. POWERVAR Single Phase Power Conditioners POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant

More information

WARRANTY & LIMITATION OF LIABILITY

WARRANTY & LIMITATION OF LIABILITY MUX-2 WARRANTY & LIMITATION OF LIABILITY 1. ROTEM warrants that the product shall be free of defects in materials or workmanship and will conform to the technical specification for a period of 1 (one)

More information

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11

Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11 Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER6TEL Highlights 7 outlets / 6-ft. cord 1080 joule rating Modem/fax surge protection $50,000

More information

SD1306. Speed Dome IP Camera. Quick User Guide

SD1306. Speed Dome IP Camera. Quick User Guide SD1306 Speed Dome IP Camera Quick User Guide Table of Contents I. Camera Introduction... 1 1. Package Contents... 1 2. Hardware Installation... 2 2.1 Factory Default... 6 3. SD card Compatibility List...

More information