1 Conel MBUS Easy CME8i USER 'S GUIDE Declared system ISO 9001:2009

2 CONTENT Contents 1. SAFETY INSTRUCTIONS DESCRIPTION OF THE CME8I Introduction Examples of possible applications M-BUS port Sleep mode Technical parameters CME8i power supply Module state indication User interfaces ETH connector description M-BUS connector description Connection of expansion port connector (PORT 1) RS Connection of expansion port connector (PORT 1) RS Connection of binary input and output Connection of relay output Power supply connector Technical parameters of communication ports CME8i configuration Standard accessories Additional accessories Assembly procedure Mechanical external dimensions and mounting recommendations Product marking Delivery identification CONFIGURATION SETTINGS OVER WEB BROWSER Network status GPRS status Power status Wake up status Run log System log LAN configuration GPRS configuration M-BUS interface configuration MEGABUS-MASTER LINE protocol RS-232/458 interface configuration MEGABUS-MASTER LINE protocol CIO configuration NTP client configuration Power supply configuration SMS configuration DynDNS client configuration Automatic update configuration Change password

3 CONTENT Set real time clock Backup configuration Restore configuration Firmware update Reboot Sleep mode QUALITY OF THE GPRS SIGNAL Antenna installation for modems Good quality GPRS requirements: Example, station received these signals: LINKS TO RELATED PRODUCTS OF THE MANUFACTURER PRODUCT DISPOSAL INFORMATION COMPLAINTS PROCEDURE WARRANTY...40 Symbols used Danger important notice, which may have influence on the user s safety or the function of the device. Attention notice of possible problems, which can arise in specific cases. Information, notice information, which contains useful advice or special interest. Conel ltd., Sokolska 71, Usti nad Orlici, Czech Republic Issued in ČR,

4 1. Safety instructions Please, observe the following instructions: CME8i SAFETY INSTRUCTIONS CME8i must be used in compliance with any and all applicable international and national laws and in compliance with special restrictions regulating the utilization of the communications of the communication module in prescribed applications and environments. To prevent possible injury to health and damage to appliances and to ensure that all the relevant provisions have been complied with, use only the original accessories. Unauthorised modifications or utilization of accessories that have not been approved may result in damage to the modem and in a breach of applicable regulations. Unauthorized modifications or utilization of accessories that have not been approved may result in the termination of the validity of the guarantee. Voltage at the feed connector of the communication module must not be exceeded. Do not plug other types of connectors to RJ45 connector; it may cause damage of these ports. Do not expose the communication module to extreme ambient conditions. Protect the communication module against dust, moisture and high temperature. CME8i must be cleaned only by weakly wetted clout, be careful to not scrounge water from clout into modem, it may cause short-circuit and possible injury to operator or destroy the modem. It is recommended that you should create an appropriate copy or backup of all the important settings that are stored in the memory of the device. Accumulator Do not hold accumulators only by contacts or connected wiring. It may cause their damage. After connecting the batteries is recommended to frame up insulating covers. It will prevent injuries of operator by electric current Do not plug accumulator (without charger) directly to 220VAC socket. Connection like this may cause destroying of accumulator or his explosion. Do not use metal equipment during installation of accumulator, like keys it may cause short-circuit of accumulator. Generated heat or sparks could sear operator, cause damage of accumulator or cause explosion. To regular charging of accumulators use only suitable charger. Their capacity and life is affected by temperature, charging voltage and other parameters. Accumulator must be cleaned only by weakly wetted clout, be careful to not scrounge water from clout into modem, it may cause short-circuit and possible injury to operator or destroy the accumulator Accumulators are recyclable. Discarded accumulators must be dissolved with compliance to all restrictions and regulations by licensed company. 4

5 2. Description of the CME8i 2.1. Introduction CME8i DESCRIPTION M-BUS Easy CME8i is device for wireless data transfer from meters with communication bus M-BUS (heat meters, water meters, electro meters, etc.) CME8i enables remote data gathering from these meters, from any dispatching, PC, Internet etc. via GSM- GPRS network. CME8i is basic communication unit in data collection system, built on MEGABUS-MASTER protocol (see: [1]). For easy use, the CME8i is in compact housing with integrated accumulator and GSM antenna. M/BUS interface is short-current proof, with function indication. As transmission protocol is used TCP in transparent mode Examples of possible applications Measuring in thermo industry. Measuring in water industry. Measuring in energy industry M-BUS port On port is standard M-BUS interface. More see the chapter Sleep mode It is possible to use power management in CME8i. Modem always switches into low power consumption after user defined time, because of possible discharge of accumulator or battery. And finally in case waking up on scheduled time after connection termination from remote side, e.g. from dispatching. Power consumption is very low in sleep mode (max. 100 µa). Modem can be wake up to online mode only by pressing button TL1 (see the picture) or by set up time to wake up modem. Duration, after that modem goes to sleep mode is possible to set up in web interface (see chapter ). Button TL1 5

6 CME8i DESCRIPTION 2.5. Technical parameters CME8i Complies with standards Frequency bands Transmit power Temperature range Supply voltage Consumption Dimensions Weight Mounting Cover Antenna connector User interfaces Safety EMC Radio Function Storage GPRS RX GPRS TX Sleep mode M-BUS RS232/485 Ethernet EN :06 ed.2 +A11:09 ETSI EN V1.8.1 EN V9.0.2 EGSM900, EGSM 850 a GSM1800, GSM1900 Based on VO-R/1/ Class 4 (2 W) pro EGSM900 Class 1 (1 W) pro GSM o C up to +55 o C -40 o C up to +85 o C +6 až +18 V DC 2 W 4 W 1 mw 197 x 147 x 78 mm 350 g On screws IP43 SMA 50 Ohm 300 b/s b/s (5x slave) 300 b/s b/s 10/100 Mb/s 6

7 CME8i DESCRIPTION 2.6. CME8i power supply The CME8i require DC voltage in range +6 V up to 18 V. Maximal nominal consumption is 4W Module state indication LED PWR GSM ETH_LINK ETH_SPD In module are five signalizations LED, which are informing about module state Description Permanently off... no power supply Permanently on(> 1 min)... faulty function Blinking slowly(9:1)... module is not registered in GSM Blinking slowly (1:9)... proper function Blinking fast... wrong PIN Permanently on... faulty function Slightly flashing trough...transmitting on high frequency channel Permanently on. connected UTP cable Slightly flashing trough.. transferring data Permanently off not connected UTP cable On. chosen speed 100 Mbit/s on Ethernet Off chosen speed 10 Mbit/s on Ethernet MB_RX Blinking or on... receiving data MB_TX Blinking or on...transmitting data MB_OVR Permanently on... short circuit or overloaded M-BUS 7

8 CME8i DESCRIPTION 2.8. User interfaces meter. In CME8i are screw plates for flexible cable for power supply or for connection M-BUS Connector for connection relay Output Connector for connection binary Input/Output Baterie / AC Power Supply Connector for connection ETH Connector for connection RS232/485 Connector for connection of M-BUS meter Power supply connector 2 Power supply connector ETH connector description Pin number Panel socket RJ45. Signal name Description Data direction 1 TxD+ Transmit data positive pole Input/Output 2 TxD- Transmit data negative pole Input/Output 3 RxD+ Receive data positive pole Input/Output RxD- Receive data negative pole Input/Output ATTENTION! ETH port is not POE (Power Over Ethernet) compatible! 8

9 CME8i DESCRIPTION Example of connection PC to CME8i: UTP cable Counter input ETH Expansion port M-BUS CME8i M-BUS connector description Pin number Screw plate. Signal description Description Data direction 1 TxRx- M-BUS B (-) Input/Output 2 GND M- GND for M-BUS BUS 3 TxRx+ M-BUS A (+) Input/Output Example of connection M-BUS meter to CME8i: M-BUS (-) Pin 1 M-BUS (-) Meter M-BUS (+) Pin 2 GND M-BUS Pin 3 M-BUS (+) CME8i Connection of expansion port connector (PORT 1) RS 232 Pin no. The RJ45 panel socket (RS232 DCE Data Communication Equipment ). Signal name Description 1 RTS Request To Send Input 2 CTS Clear To Send Output 3 DTR Data Terminal Ready Input 4 DSR Data Set Ready connected to +4V trough R 330 Ω Output 5 GND GROUND signal ground 6 RXD Receive data Output 7 CD Carrier Detect Output 8 TXD Transmit Data Input Data flow direction 9

10 CME8i DESCRIPTION Circuit example of the meter with modem CME-8i: Meter GND RXD TXD Pin 1 RTS Pin 2 CTS Pin 3 DTR Pin 4 DSR Pin 5 GND Pin 6 RXD Pin 7 CD Pin 8 TXD CME-8i Circuit example of the PC with modem CME-8i: KD-2 cable M-BUS ETH Expansion (PORT 1) Counter input CME-8i The KD2 cable is connected to serial PC port (for example COM1) Circuit example of the RS232 equipment with modem CME-8i: Kabel KD-2 M-BUS ETH PORT1 Counter input CME-8i 10

11 CME8i DESCRIPTION Connection of expansion port connector (PORT 1) RS 485 Pin no. The RJ45 panel socket. Signal mark Description Data flow direction TxRx- RS485B (-) Input/Output TxRx+ RS485A(+) Input/Output Circuit example of the meter connection to modem CME-8i with data cable length less than 10 m: Meter SGND RS485 (-) RS485 (+) Pin Pin Pin 3 RS485 (-) Pin Pin Pin 6 RS485 (+) Pin Pin CME-8i Meter SGND RS485 (-) RS485 (+) 11

12 CME8i DESCRIPTION Circuit example of the meter connection to modem CME-8i with data cable length more than 10 m: Meter SGND RS485 (-) RS485 (+) 1X 1Y 2Y 2X OVPM-21 Pin Pin Pin 3 RS485 (-) Pin Pin Pin 6 RS485 (+) Pin Pin CME-8i Meter SGND RS485 (-) RS485 (+) At RS485 data cable more than 10 m it is need to use over-voltage protection on CME-8i modem side! Connection of binary input and output Pin no. Screw plate Signal mark Description Data flow direction 1 IN1 Binary input or output 1 Input/Output 2 GND Ground signal ground 3 IN0 Binary input or output 0 Input/Output Circuit example of a Binary or output equipment with modem CME-8i: Binary meter IN1 GND IN0 IN1 GND IN0 CME-8i Connector binary input and output cans connect in function: o Binary input o Binary output o Binary counter o Two-way binary counter(one input uses for indication of direction) 12

13 Connection of relay output Pin no. Screw plate Signal mark Description CME8i DESCRIPTION Data flow direction 1 S1 Output relay 1 Output 2 COM Ground 3 S2 Output relay 2 Output Circuit example of a relay output equipment with modem CME-8i. Relay 1 S1 COM S1 COM S2 CME-8i Relay 2 S2 COM Output for relay S1 is normally open. Output for relay S2 is normally close Power supply connector Pin number Screw plate. Signal description 1 GND Negative pole of DC power supply Description 2 +UN Positive pole of DC power supply (+6 up to +18 V) Example of connection: Power supply or battery DC CME8i + Connectors for power supply are connected that way to allow connection of two independent power supplies, which not affect each other. 13

14 2.9. Technical parameters of communication ports M-BUS RS232 (ČSN EN 1434) RS485 (ČSN EN 1434) Bus M-BUS (EN 1434) CME8i DESCRIPTION Max. operating bus current 15 ma Max. bit rate bps Max. overvoltage ±30V Max. total cable (300Bd, 200nF/km) 20m Max. devices (each 1.5 ma) 256 Max. bit rate bps Overload detection 250 ma Short circuit protection Permanent Max. total cable length (300Bd, 200nF/km) 1200 m Max. devices (each 1.5 ma) 5 Max. operating bus current 50 ma Overcurrent detection 70 ma Short circuit endurance Permanent Bus voltage mark Bus voltage space Max. capacity of cable (2400 Bd) V V 50nF CME8i configuration Attention! Without inserted SIM card, GPRS data transfers will not be available. Inserted card must have activated GPRS transfers. Switch off modem when inserting SIM card. For observing state, configuration and to manage modem, the web interface (described in chapter 3. ) is at disposal. It can be accessed by enter the IP address of modem into web browser. Default IP address is Configuration can be done only by user named root with default password root. This password must be changed in web configuration interface (see chapter ) Standard accessories Declaration of conformity Compliance certificate. Warranty. User s guide Additional accessories Flexible cable. UTP cable. 14

15 2.13. Assembly procedure Assembly to a panel using the through holes in the CME8i. CME8i DESCRIPTION Through holes Mechanical external dimensions and mounting recommendations Place for UTP and a data cable For majority of applications with a built in modem in a switch board it is possible to recognize two sorts of environments. no-public and industry environment of low voltage with high interference, public environment of low voltage without high interference 15

16 CME8i DESCRIPTION For both of these environments it is possible to mount modems to switch board, the following it is not need have no examination immunity or issues in connection with EMC according to EN A1. For compliance of EN A1 specification it is necessary observe next assembly of the modem to the switch - board: for single cables we recommended to bind the bunch according to the following picture, for this use we recommend: we recommend to use efficient case to detente (ex. Mossplastics type SR1730 or SR1711), for power supply we recommend H05VV-F 3 x 0.75 cable for data transmitting we recommend H05VV-F 2 x 0.75 cable efficient power supply protection is 6 A with B type time-current characteristic sufficient space must be left before individual connectors for handling of cables 16

17 CME8i DESCRIPTION Product marking Trade name Type name Interface Additional accessories CME8i CME8i 1 x M-BUS Flexible cable for 1 x ETH M-BUS, UTP cable 1 x RS232/RS485 Power supply +6 up to +18 V DC Delivery identification 17

18 WEB CONFIGURATION 3. Configuration settings over web browser For monitoring status, configuration and administration of modem can be done by web interface. It can be accessed by entering IP address of router to web browser. Default IP address is Configuration can be done only by user named root with default password root. This password must be changed in web configuration (see chapter ). The left part of the web interface contains the menu with pages for monitoring of the Status, configuration and Administration of the modem. After PWR LED starts to blink it is possible to restore default settings by pressing button TL1 for at least 5 seconds Network status Information about network status is possible to find in menu in sum Network. In window is displayed information about network interfaces. For every interface can be seen this information: MAC Address hardware(unique) address of networks interface (only for LAN) IP Address own IP address Rx Bytes count of received Bytes Rx Packets count of received packets Rx Errors count of received errors Rx Dropped count of dropped packets Tx Bytes counts of transmitted Bytes Tx Packets count of transmitted packets Tx Errors count of transmitted errors Tx Dropped count of dropped packets 18

19 WEB CONFIGURATION If the GPRS connection is active, in Network is displayed his network information GPRS status GPRS item consist of actual information about SIM card and about settings PIN code on SIM card. If the SIM card is not properly inserted or is it locked by PIN code, user is informed about it. Also is possible to find here information about connection to mobile network. They are: code of operator (PLMN), cell, channel, signal quality of chosen cell, as well as about neighbouring hearing cells. If the signal strength is in red, this means that signal is insufficient and connection could be inaccessible. If is in red the signal strength of some neighbor cell, it means that could interfered with selected cell. In this case, solution could be to adjust GPRS antenna. (See chapter 4. ) 19

20 WEB CONFIGURATION In this given example can be seen that there is thread of reselection between chosen cell on channel 30 and neighbor cell on channel 80, because their signal strength is very close Power status Information on power supply can be called up in option Power status in the main menu. Window is separated into 3 sections. Each section represents one available battery. If battery is inserted, type of installed battery, voltage and estimated capacity is displayed. In case of fixed power source, only status of supply voltage is displayed. Sections VBAT1 and VBAT2 displays operational parameters of external batteries. For example accumulator that can be connected to battery connector BAT1 and BAT2. VBAT providing voltage and capacity of internal battery for run in sleep mode. Type of external battery can be chosen in Power management in main menu (see chapter ). Choice of the battery type has influence to estimated capacity of the battery Wake up status Information about power supply can be called up in option Wake Up Status in the main menu. It is possible to find here these information: Reset time time, when modem have woke up from sleep Current time actual time in the moment of the page upload Next activity time time of next activity Next wake up time time of the next wake up from sleep mode Time to sleep time remaining to switch to sleep mode 20

21 WEB CONFIGURATION 3.5. Run log Run log can be called up in option Run log. Information like wake up time and sleep time are stored here System log In case of any problems with modem, system log can be called up in option System Log. Reports from each subsystem of modem are stored here. But only limited number of reports is remembered. After restart old reports are deleted. 21

22 WEB CONFIGURATION 3.7. LAN configuration To enter the network configuration, select the LAN menu item. In the first part of the window is possible to define the network interface IP address and the network mask (Subnet Mask). In second part of the window is possible to define the DHCP server by checking the Enable DHCP server. In window it is possible to define the beginning (IP pool start) and end (IP Pool End) of the pool of IP addresses which will lease to DHCP clients. If enable DHCP server is left unchecked the DHCP server will not lease IP addresses. The changes in settings will apply after pressing the Apply button. The DHCP server assigns IP addresses to the connected clients from defined address pool, IP address of gate and IP address of the primary DNS server. It is important not to overlap ranges of static engaged IP address with address allotted by DHCP, or collision of addresses may occur, thereby malfunction the network GPRS configuration To enter GPRS configuration select the GPRS menu item. Here can be entered access point name (APN), username and password. If the Check PPP connection option is selected, it has active control of connection over PPP. The CME8i will automatically send the ping question to the selected domain name or IP address (Ping IP Address) in periodic time intervals (Ping Interval). After three unsuccessfully pings on appropriate IP address the router terminates connection and tries to establish a new connection. It is possible to use, for example, the DNS server of a mobile operator as the ping IP address. If the Enable Traffic Monitoring option is selected, then the CME8i stops sending ping questions to the Ping IP Address and it will watch traffic in PPP connection. If PPP connection is without traffic longer than the Ping Interval, then the router sends ping questions to the Ping IP Address. The changes in settings will apply after pressing the Apply button. 22

23 WEB CONFIGURATION 3.9. M-BUS interface configuration M-BUS interface configuration can be accessed by clicking on M-BUS item from menu. In first section is possible to choose transport protocol for data. It can be done by clicking on Change button. For every protocol are available these settings of M-BUS: Baudrate speed of transmitted data, Data Bits count of data bits, Parity parity, Stop Bits count of stop bits, Split Timeout bursting timeout for messages Which protocol is used, to communicate on M-BUS interface, is chosen by clicking on Change button. After click, the list of supported protocols will expand. The changes will apply after pressing the Apply button. For each protocol is provided different possibilities of settings: 23

24 MEGABUS-MASTER MEGABUS-MASTER protocol adds these settings: Remote IP Address, Remote Port, Reply Timeout, Config ID configuration identifier, read only. WEB CONFIGURATION Finally it is possible to add meters. These parameters are provided: Meter ID meter identification, Meter Type type of meter device, (MBUS or CIO), Meter Address address of device on M-BUS, Readout Values count of readout values. The choice is confirmed by clicking on Add. 24

25 WEB CONFIGURATION After add all connected meters the meters will saved after pressing the Add button. Detailed information about MAGABUS-MASTER protocol can be found in documentation [1]. Example of MEGABUS-MASTER protocol configuration: LAN CME8i M-BUS ID: 1234 Address: 11 IP: Mask: Local port: IP: Remote IP: Remote port: CIO ID: 5678 On the pictures are shown example of configuration of MEGABUS-MASTER. To CME8i is connected one M-BUS meter and also is used CIO meter. There are 5 values read over M-BUS in this order: 1, 3, 5, 6, 4. The second value is not required and the fourth value is required as last. Meter address is 11. Read values are represented by user defined number ID: From CIO module are read all four values in standard order. Address is ignored LINE protocol In case of LINE protocol, these settings are added: Mode possible to choose TCP server, TCP client or UDP connection, Local Port local port, if not entered, system chooses one. Number of port can be obtained in System Log. Remote IP Address IP address of remote device, Remote Port port on device, Reply Timeout time to reply. 25

26 WEB CONFIGURATION In case of TCP server or UDP connection are Remote IP Address and Remote Port items ignored. Reply is sent to remote device which caused request. The changes will apply after pressing the Apply button. Example of CME8i connection and configuration (LINE protocol): Monitoring LAN CME8i M-BUS Meter 1 IP: Mask: Local Port: IP: Local Port: Remote IP: Remote port: Meter 2 Meter 3 26

27 WEB CONFIGURATION RS-232/458 interface configuration RS-232/485 interface configuration can be accessed by clicking on RS-232/485 item from main menu. In first section is possible to choose transport protocol for data. It can be done by clicking on the Change button. For every protocol are available these basic settings: HW Interface possibility to choose between RS232 and RS485 Baudrate speed of data transmission, Data Bits count of data bits, Parity parity, Stop Bits count of stop bits, Split Timeout bursting timeout for messages Which protocol is used, to communicate on RS232/485 interface, is chosen by clicking on the Change button. After click, the list of supported protocols will expand. The changes will apply after pressing the Apply button. For each protocol is provided different possibilities of settings: 27

28 WEB CONFIGURATION MEGABUS-MASTER MEGABUS-MASTER protocol adds these settings: Remote IP Address, Remote Port, Reply Timeout, Config ID configuration identifier, read only. Finally it is possible to add meters. These parameters are provided: Meter ID meter identification, Meter Type type of meter device, (MBUS or CIO), Meter Address address of device on M-BUS, Readout Values count of readout values. The choice is confirmed by clicking on Add. 28

29 WEB CONFIGURATION After add all connected meters the meters will saved after pressing the Add button. Detailed information about MAGABUS-MASTER protocol can be found in documentation [1] LINE protocol In case of LINE protocol, these settings are added: Mode possible to choose TCP server, TCP client or UDP connection, Local Port local port, if not entered, system chooses one. Number of port can be obtained in System Log. Remote IP Address IP address of remote device, Remote Port port on device, Reply Timeout time to reply. In case of TCP server or UDP connection are Remote IP Address and Remote Port items ignored. Reply is sent to remote device which caused request. 29

30 WEB CONFIGURATION The changes will apply after pressing the Apply button, placed on the bottom of main page of configuration of RS232/485 interface CIO configuration CIO configuration can be called up by clicking on CIO item. Two counter inputs are provided. Each input has different settings possibilities. Disabled off, Common Input common input, Wake up Input 0 wake up on signal from CIO 0 input. When input changes from high to low level, then wake up is triggered. Wake up Input 1 wake up on signal from CIO 1 input. When input changes from high to low level, then wake up is triggered. Unidirectional counter counter is only up counting. Both counters count up. Bidirectional counter both counters counts up, but they can recognize a phase shift on inputs so it can measure e.g. flow direction. The changes will apply after pressing the Apply button NTP client configuration To enter NTP client configuration, select the NTP menu item. In the window can be defined the address primary (Primary NTP Server) and secondary (Secondary NTP Server) NTP server, by the help of which the router will adjust the inner clock. The changes will apply after pressing the Apply button. 30

31 3.13. Power supply configuration WEB CONFIGURATION Power supply configuration can be called up by click on the Power Management item. Power management (also sleep mode) is enabled by checking Enable in top of the window. Minimal activity time means that the modem never goes sleep before this time will be expired. Maximal activity time: modem never exceeds this time and after it is expired always goes to sleep. Both values are in seconds. Between these times, modem goes to sleep immediately after termination of connection. In second part of the window (Installed battery type) is possible to choose the type of external power source. It affects estimated capacity of the battery in Power status. These possibilities are available: Fixed power source typically AC adapter, status of supply voltage only is displayed Unknown battery capacity is estimated based on linear characteristic Saft 3x LS battery of three cells SAFT LS Panasonic CGR18650 battery of cells Panasonic CGR18650 In next part of the window is possible to enter Minimal battery level for both (external and internal) batteries. If these values are breached, the appropriate alarm is set in sent data over MEGABUS-MASTER protocol. Example of settings: On picture below is allowed power management (sleep mode), so modem goes to sleep maximally after 300s (5minutes). But if remote user will read values sooner modem will turn to sleep after 60s or after terminating connection. Minimal battery limit is also set. Alarm will be set after external battery capacity goes below 30% or internal battery capacity goes below 10%. 31

32 WEB CONFIGURATION In the last part is displayed information about waking up rules. There are possible to enter up to 128 rules. The rules can be entered by clicking on Add and are deleted by clicking on Delete for every rule separately. These rules can be saved on PC by clicking on Export, or restored from PC by clicking on Import. The changes will apply after pressing the Apply button. The window for enter the rules are divided into 8 rows. It is possible to enter only one rule at once. When adding new rule, select suitable row and then fill cyclic wake up time. (In case of CIO event, selects the channel number, which wakes up modem). The choice is confirmed by clicking on Add. If we set wake up every 8 minutes, modem is waking up every 8 minutes since the early hours. Example in 8:08, 8:16 For example: for waking up every 2days in 3 o clock, the most suitable row is the third from top. Here is entered: every 2 days, at 03:00:00 o'clock and confirmed by Add button SMS configuration To open the dialog box for SMS configuration about battery low status select the SMS configuration menu item. In the top window can be defined what information about battery sends by checking Send SMS on In the bottom window can be defined one, two or three phone number, by sends SMS information about battery low status. 32

33 3.15. DynDNS client configuration WEB CONFIGURATION DynDNS client Configuration can be called up by option DynDNS item in the menu. In the window can be defined a third order domain registered on server (Hostname), user name (Username) and password (Password). The changes in settings will apply after pressing the Apply button. If DNS servers are not assigned by the operator, then it is possible to configure it by inserting of script into start up window: echo nameserver xxx.xxx.xxx.xxx > /etc/resolf.conf, where xxx.xxx.xxx.xxx is IP address of the first DNS server, echo nameserver yvy.yyy.yyy.yyy >> /etc/resolf.conf, where yvy.yyy.yyy.yyy is IP address of the second DNS server Automatic update configuration In the window Automatic update it is possible to set automatic configuration update. This choice enables that the router automatically downloads the configuration from the server itself. The configuration are stores on the server. By Enable automatic update of configuration it is possible to enable automatic configuration update By parameter Base URL it is possible select http or ftp protocol and to enter domain or IP address, from which the configuration file will be downloaded. The contents of parameter Unite ID is added to Base URL. The configuration file name is from parameter Base URL, name from parameter Unit ID and cfg extension. Cfg extension is connected automatically and it isn t needed to enter this. By parameter Unit ID enabled it defines the concrete configuration name which will be download to the router. The changes in settings will apply after pressing the Apply button. 33

34 3.17. Change password WEB CONFIGURATION To open the dialog box for changing the access password select the Change Password menu item. The new password will be saved after pressing Apply button. In basic settings of the modem the password is set on default form root. For higher security of your network we recommend changing this password Set real time clock One-shot inner clock of the modem setting can be called up in option Set Real Time Clock item in menu. Clock is set according to the engaged NTP server after push-button operation Apply Backup configuration The modem configuration is possible to save by help of the Backup Configuration menu item. After clicking on this menu it is possible to choose destination directory, where it will save the router configuration Restore configuration In case it is needed to restore the modem configuration, it is possible in Restore Configuration menu item to choose configuration by Browse button. 34

35 WEB CONFIGURATION Firmware update To view information about the firmware version and instructions for its update select the Update Firmware menu item. The new firmware will be checked after pressing Browse button and update the following pressing the Update button Reboot To reboot the modem select the Reboot menu item and then press the Reboot button. Modem remains in web interface Reboot after reboot modem Sleep mode Sleep can be called up by clicking on Sleep menu item and then clicking on Sleep button. The modem goes into sleep mode, after every process stops. 35

36 LINKS AND INFORMATIONS 4. Quality of the GPRS signal CME8i Modems works with the aid of the GSM network. Modems contain GSM-GPRS modules, which are on the radio channel connected to a certain GSM cell. Its signal can be evaluated and displayed in web configuration of CME8i modem. The function is used first of all when installing the station and checking its function. From the obtained information, the following can be read: On which channel the station operates what is its signal strength, what neighbor channels are available and what their signal is strength. These data are often indispensable for the correct installation of the antenna Antenna installation for modems Good placement of antenna is required for good function. Important factors are GSM cell signal strength and signal quality. Signal strength could be obtained in web configuration in GPRS menu item. Second part is quality of signal. There is no exact measurement. Good point of view is from data transfer statistic. If number of lost packet is low, signal quality is good Good quality GPRS requirements: Serving cell signal better than 90 dbm, Adjacent cell signal below 12dB to serving cell, otherwise risk of interference If many cells with close levels (<3 db), be in danger of reselection (switch between cells, that caused bad time response or communication interruption). In this case is needed to extend difference between signals Example, station received these signals: PLMN : Cell : 69A6 Channel : 30 Level : -71 dbm (Ok) Neighbours : -76 dbm (80), -77 dbm (106), -82 dbm (57) 36

37 LINKS AND INFORMATIONS What does it means: module received cell 69A6 on channel 30 with level 71dBm, operator is 23001, there is possible to interference from channel 80, with level -79dBm, there is possible to reselection between channels 80 and 106, its level is so close. Way to fix Change type (from unidirectional to directional e.g. yagi), direction or place of antenna. After changing you must do measurements again. 5. Links to related products of the manufacturer Related products and materials with a reference can be found on the manufacturer s website Conel company: [1] The MEGABUS MASTER protocol, CME-8i_MEGABUS-MASTER_en.pdf, Conel ltd, Product disposal information The WEEE (Waste Electrical and Electronic Equipment: 2002/96/EC) directive has been introduced to ensure that electrical/electronic products are recycled using the best available recovery techniques to minimize the impact on the environment. This product contains high quality materials and components which can be recycled. At the end of its life this product MUST NOT be mixed with other commercial waste for disposal. Check with the terms and conditions of your supplier for disposal information. 37

38 COMPLAINTS PROCEDURE 7. Complaints procedure Dear customer The product you have purchased had passed manufacturers tests and its functions had been checked by our technician before sale. In case any defect shows up during the guarantee period that prevents normal use we ask you to follow the Complains procedure when registering your claim. To make possible complaint procedure easier please make sure when taking over the product your vendor has duly filled in all relevant parts of the warranty, including date, seal and signature. This complains procedure relates to the purchased products. This complains procedure does not relate to the services provided. Guarantee period of the products Guarantee period of 24 months from the date of purchase is provided for the device, source, antenna, data cable and possible accessories. The date of purchase is at same time date of takeover. Registering a claim It is necessary to register your claim at the vendor where the subject of the complaint has been purchased. The customer shall present duly filled warranty and the complete subject of the complaint. Subject of the complaint shall be presented in a condition adequate to that at the moment of purchase. Caution! The vendor is not responsible for keeping individual settings or data saved in the subject of the complaint. The customer is obliged to clarify the defect or how it is displayed and what claim he intended to register. Processing the complaint The vendor shall provide a free remedy depending on particular conditions, or replace the subject of the complaint for a new product, or settle the matter in another manner in compliance with the Civil Code and the Act on consumer s protection. As of the moment the claim is registered by the customer and the subject of the complaint is taken over by the vendor the vendor the guarantee period stops running. The guarantee period continues on the date of takeover of the repaired subject of the complaint or replaced faultless product by the customer, or should it not be taken over on the date the customer is obliged to take over the repaired or replaced product. In case the vendor replaces the subject of the complaint for a new product (including IMEI replacement) the original subject of the complaint becomes property of the purchaser. Since takeover of the new product a new guarantee period starts. In the cases when the vendor settles the matter after agreement with the customer by replacement of the subject of the complaint for a faultless product the new guarantee expires. 38

39 COMPLAINTS PROCEDURE 1. After 12 months since the replaced product was taken over by the customer. 2. On the date when the original guarantee period (subject of the complaint) would have expired should it not have been replaced, whichever comes first. 3. The claim is deemed unsubstantiated when the defect is not found by the vendor processing the complaint or the defect is not covered by the guarantee under Article 4 of the procedure. 4. In case the claimed defect is not found and functionality is proven to the customer, the customer is obliged to pay demonstrable cost related to expert assessment of the claimed defect. 5. In case defect is found when processing the complaint that is not covered by the guarantee (extra-warranty repair), the vendor shall inform the customer and the customer shall inform the vendor whether he/she wishes to have the defect repaired for the price set. A protocol shall be made on exact conditions of the extra-warranty repair and signed by both the customer and the vendor. Should the customer not require remedy through ad extra-warranty repair under the conditions, the device shall be returned to him/her after he/she pays the demonstrable cost of expert assessment. The guarantee does not cover defects incurred due to 1. Mechanical damage (fall and the like). 2. Use of inadequate or not recommended sources and other accessories. 3. Connection of the product with non-standard accessories. 4. Installation or use of the product conflicting with the Manual or use for other purposes than usual for this type. 5. Improper manipulation or an intervention of unauthorized person or other purposes than usual for this type. 6. Effects of natural forces (flood, fire etc.) or other local phenomena (storm, overvoltage and the like). 7. Storage under unauthorized temperatures. 8. Operation in a chemically aggressive environment. Other conditions The fact that the subject of the complaint does not conform to parameters set for other similar product types shall not be considered a fault. To assess whether it is a case of covered fault the parameters stated in the technical documentation for the product are decisive. The guarantee expires in any case of changes to the subject of the complaint, or damaged or otherwise unreachable serial number. 39

40 WARRANTY 8. Warranty Device type Serial number Guarantee period (in months) Vendor Data of purchase Seal of the seller 40

41 WARRANTY Date of reception of the guarantee claim by the seller Number of the guarantee claim report Date of reception of the device into the repair shop Date of completion of the repair by the repair shop Number of the receipt form of the repair shop Guarantee repair YES - NO YES - NO YES - NO YES - NO YES - NO New serial number of the device (IMEI) Comments Stamp of the repair shop 41

Expansion Port RS485/RS422

Expansion Port RS485/RS422 Expansion Port RS485/RS422 www.lucom.de info@lucom.de USER S MANUAL USED SYMBOLS Used Symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention

More information

Expansion port ETH USER S GUIDE

Expansion port ETH USER S GUIDE OBSAH Expansion port ETH USER S GUIDE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible problems,

More information

/ Expansion port MBUSD OBSAH USERS GUIDE

/ Expansion port MBUSD OBSAH USERS GUIDE WWW.INFOPULSAS.LT / info@infopulsas.lt OBSAH Expansion port MBUSD USERS GUIDE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the

More information

Danger important notice, which may have an influence on the user s safety or the function of the device.

Danger important notice, which may have an influence on the user s safety or the function of the device. CONTENTS Contents 1. Safety instructions 4 2. Description of the CGK 5 GSM key 5 2.1. General description 5 2.2. Examples of using 5 2.3. Description of the individual parts of the CGK 5 5 2.3.1 Programmable

More information

Danger important notice, which may have an influence on the user s safety or the function of the device.

Danger important notice, which may have an influence on the user s safety or the function of the device. CGK-5x USER'S GUIDE SYMBOLS USED Symbols used Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible problems, which can arise

More information

Expansion Port RS232 USER MANUAL

Expansion Port RS232 USER MANUAL Expansion Port RS232 USER MANUAL Used Symbols Danger Information regarding user safety or potential damage to the router. Attention Problems that can arise in specific situations. Information, notice Useful

More information

Expansion Port RS485/RS422 USER MANUAL

Expansion Port RS485/RS422 USER MANUAL Expansion Port RS485/RS422 USER MANUAL Used Symbols Danger Information regarding user safety or potential damage to the router. Attention Problems that can arise in specific situations. Information, notice

More information

EDGE router ER75i. Content of package : Modem ER75i Power supply Antenna Crossover UTP cable Installation CD with instruction and drivers

EDGE router ER75i. Content of package : Modem ER75i Power supply Antenna Crossover UTP cable Installation CD with instruction and drivers Content of package : Modem ER75i Power supply Antenna Crossover UTP cable Installation CD with instruction and drivers Safety Instruction EDGE router ER75i Please, observe the following instructions: The

More information

Expansion port WIFI OBSAH. USER S GUIDE

Expansion port WIFI OBSAH.  USER S GUIDE OBSAH Expansion port WIFI USER S GUIDE SYMBOLS USED Symbols used Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible problems,

More information

Industrial router XR5i USER S MANUAL.

Industrial router XR5i USER S MANUAL. Industrial router XR5i v2e www.leitsystem.ch host@leitsystem.ch USER S MANUAL USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the

More information

Industrial router XR5i USER S MANUAL

Industrial router XR5i USER S MANUAL Industrial router XR5i v2 USER S MANUAL USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible problems,

More information

User module. Guest Configuration APPLICATION NOTE

User module. Guest Configuration APPLICATION NOTE User module Guest Configuration APPLICATION NOTE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible

More information

Expansion Port CNT USER MANUAL

Expansion Port CNT USER MANUAL Expansion Port CNT USER MANUAL Used Symbols Danger Information regarding user safety or potential damage to the router Attention Problems that can arise in specific situations Information, notice Useful

More information

Radio data modem CDX 800 USER S GUIDE.

Radio data modem CDX 800 USER S GUIDE. Radio data modem CDX 800 USER S GUIDE WWW.INFOPULSAS.LT info@infopulsas.lt OBSAH Contents 1.SAFETY INSTRUCTIONS...4 2.DESCRIPTION OF THE CDX 800 COMMUNICATION MODULE...5 2.1.General description...5 2.2.Examples

More information

Expansion Port SWITCH USER MANUAL

Expansion Port SWITCH USER MANUAL Expansion Port SWITCH USER MANUAL Used Symbols Danger Information regarding user safety or potential damage to the router. Attention Problems that can arise in specific situations. Information, notice

More information

RM6000 GPRS Modem / Router

RM6000 GPRS Modem / Router User Manual Version 6.30 AMG Systems Ltd March 2013 3 The Omega Centre Stratton Business Park Biggleswade Bedfordshire, UK SG18 8QB Tel: 44 (0) 1767 600777 sales@amgsystems.com 1. Introduction 2. RM6000

More information

ER75i v2. EDGE router. and ER75i v2 SL USER S GUIDE

ER75i v2. EDGE router. and ER75i v2 SL USER S GUIDE ER75i v2 and ER75i v2 SL EDGE router USER S GUIDE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on

More information

Radio data modem USER S GUIDE CDX 800

Radio data modem USER S GUIDE CDX 800 Radio data modem USER S GUIDE CDX 800 OBSAH Contents 1.SAFETY INSTRUCTIONS...4 2.DESCRIPTION OF THE CDX 800 COMMUNICATION MODULE...5 2.1.General description...5 2.2.Examples of possible applications...5

More information

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS SWH Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS Rev.1 01/03/2013 1. Overview The SWH is a complete board Cellular Terminal solution for GSM GPS/GLONASS applications.

More information

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter Login for the first time, please use http://192.168.1.100 To key in user name and password is for identifying authorization. Default

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

Product description Rev. 3 11/06/14

Product description Rev. 3 11/06/14 EZ863-2G - GNSS Product description Rev. 3 11/06/14 1 Table of Contents 1. Overview... 4 2. General Description... 4 2.1 Dimensions... 4 2.2 Weight... 4 2.2 Installation... 5 2.3 Casing material... 6 2.4

More information

GC 055. GSM Remote Monitoring. Operating and installation instructions

GC 055. GSM Remote Monitoring. Operating and installation instructions GSM Remote Monitoring Operating and installation instructions GC 055 GSM, GPRS Programmable Communicator Transmits input conditions/controls outputs Measures analogue data Access control system/dallas

More information

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A)

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A) Modem/Router INSTRUCTION MANUAL (M179B01-03-17A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could result in personal injury

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

Operation Manual GSM modem irz TG42-232

Operation Manual GSM modem irz TG42-232 Operation Manual GSM modem irz TG42-232 Table of Contents 1. Introduction... 4 1.1. About this Document... 4 1.2. Service Information... 4 1.3. Safety Precautions... 4 2. Overview... 5 2.1. Purpose...

More information

SmartSwarm 351 Quick Start Guide

SmartSwarm 351 Quick Start Guide ! SmartSwarm 351 Quick Start Guide Introduction The SmartSwarm 351 IIoT gateway is for operators of existing Modbus networks wishing to import a real time data feed from their process system into IIoT

More information

GSM SECURITY AND CONTROL SYSTEM ESIM021

GSM SECURITY AND CONTROL SYSTEM ESIM021 GSM SECURITY AND CONTROL SYSTEM ESIM021 Manual v1.1 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: Alarm and control system

More information

EDGE router ER75i v2 and ER75i v2 SL USER S GUIDE

EDGE router ER75i v2 and ER75i v2 SL USER S GUIDE KOMPONENTEN & SYSTEME EDGE router ER75i v2 and ER75i v2 SL USER S GUIDE OBSAH Contents 1. Safety instruction 5 2. Description of the router 6 2.1. Introduction 6 2.2. Delivery Identification 7 2.3. Antenna

More information

USER MANUAL FOR GS100/GS1003G

USER MANUAL FOR GS100/GS1003G USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...

More information

mark150s mark150/485s DDC controllers Summary

mark150s mark150/485s DDC controllers Summary mark150s mark150/485s DDC controllers Summary DDC (Direct digital control) controller mark150s and mark150/485s are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They

More information

EZ864 UMTS Terminal Telit Cellular GSM Engine

EZ864 UMTS Terminal Telit Cellular GSM Engine EZ864 UMTS Terminal Telit Cellular GSM Engine Version: 01.01 EZ864 UMTS Terminal_HD_V01.01 06.Mar.2008-1 - Hardware Interface Description 1. Hardware Features of the EZ864 UMTS Terminal Feature Implementation

More information

EDGE router ER 75i, ER 75i DUO and ER 75i SL USER S GUIDE

EDGE router ER 75i, ER 75i DUO and ER 75i SL USER S GUIDE EDGE router ER 75i, ER 75i DUO and ER 75i SL USER S GUIDE CONTENTS Contents 1. Safety instructions 5 2. Description of the ER 75i, ER 75i DUO and ER 75i SL routers 6 2.1. Introduction 6 2.2. Delivery Identification

More information

A1000 GSM ALARM DEVICE

A1000 GSM ALARM DEVICE A1000 GSM ALARM DEVICE USER MANUAL A1000-REV2.1-1604 FW-A1000v2.93 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for installation,

More information

GPRS Pager 3 INSTALATION AND USER MANUAL

GPRS Pager 3 INSTALATION AND USER MANUAL GPRS Pager 3 INSTALATION AND USER MANUAL 1 Table of contents 1 Main functions of the GPRS Pager3...3 2 Operating mode, installation...3 2.1 Installation if no local network is available...3 2.2 Instalation

More information

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host) Package Contents Before installing your R3000 Lite Router, please verify the kit contents as following. 1 x Robustel R3000 Lite Industrial Dual SIM Cellular VPN Router 1 x 3-pin pluggable terminal block

More information

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface

More information

Quick Start M!DGE / MG102 Wireless Router 6/13/2017

Quick Start M!DGE / MG102 Wireless Router 6/13/2017 6/13/2017 1. Welcome Thank you for buying M!DGE / MG102 Wireless Router from RACOM. Please read this Quick Start Guide carefully since it contains important security notes (section 2) and compliance information

More information

+70 C -25 C 95% RH EMC

+70 C -25 C 95% RH EMC +70 C -25 C 95% RH EMC TK701G TK701U TK711U TK704G TK704U TK714U TK704W TK700 The industrial 2G GPRS- and 3G UMTS routers offered by Welotec enables the access to Ethernet devices or a local network remotely

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation

More information

F3123 GPRS ROUTER USER MANUAL

F3123 GPRS ROUTER USER MANUAL F3123 GPRS ROUTER USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation. Embedded Modbus TCP Module GS11-MT User Manual REV 1.1 SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 About the Embedded Module... 4 1.1 General...4 1.2 Features... 4 1.3 Specifications...4

More information

I/O ETHERNET CONTROLLER ELAN1

I/O ETHERNET CONTROLLER ELAN1 I/O ETHERNET CONTROLLER ELAN1 Manual v1.0 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: Don t use the system in hazardous

More information

NetBiter Serial Server User Manual

NetBiter Serial Server User Manual User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

TELTONIKA ModemCOM (TMC-10x) User Manual V

TELTONIKA ModemCOM (TMC-10x) User Manual V TELTONIKA ModemCOM (TMC-10x) User Manual V2.1.1.18 TABLE OF CONTENTS ATTENTION!...3 LEGAL NOTICE...3 INTRODUCTION...4 1. PACKAGE CONTENTS...5 2. TECHNICAL SPECIFICATIONS...6 2.1. Data transferring...6

More information

CONTENTS. Symbols used. GPL licence

CONTENTS. Symbols used. GPL licence 1 CONTENTS Contents 1. Safety instructions 4 2. Description of ER75i router 5 2.1. Introduction 5 2.2. Delivery Identification 5 2.3. Antenna Connection 7 2.4. SIM Card Reader 7 2.5. Power Supply 7 2.6.

More information

GNS-MC35iT, GNS-MC35iU Terminals datasheet

GNS-MC35iT, GNS-MC35iU Terminals datasheet datasheet 2007 Contents Document history...3 1 Abstracts...4 2 Key features...4 3 Electrical and environmental characteristics...5 4 Operating modes...7 5 Power supply...8 6 Power on/off control...9 7

More information

Extension module for graphic Web functions for one automation station

Extension module for graphic Web functions for one automation station s 9 266 9263p01 DESIGO PX Extension module for graphic Web functions for one automation station Plugs into the modular automation stations, type PXC...-U For operation of the PXC -U automation stations

More information

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1 A1400 GSM Temperature Alarm USER MANUAL A1400-REV2.1-1604 FW-A1400v2.94 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for

More information

CDMA/UMTS router UCR11 v2 and UCR11 v2 SL USER S GUIDE

CDMA/UMTS router UCR11 v2 and UCR11 v2 SL USER S GUIDE CDMA/UMTS router UCR11 v2 and UCR11 v2 SL USER S GUIDE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

ER 75i DUO, ER 75i SL

ER 75i DUO, ER 75i SL EDGE router ER 75i, ER 75i DUO, ER 75i SL and ER 75i DUO SL www.lucom.de info@lucom.de USER S GUIDE CONTENTS Contents 1. Safety instructions 5 2. Description of the ER 75i, ER 75i DUO, ER 75i SL and ER

More information

1. Short description. 2. Features. 3. Technical parameters

1. Short description. 2. Features. 3. Technical parameters 1. Short description TCW122B-RR is a remote relay control module with embedded WEB server for set up. The device has two digital inputs and two relays, with normally open and normally closed contacts.

More information

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel:

Energy Client. Version Feb Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: Energy Client Version 2.0.806 3. Feb. 2014 Electrocom Rødeledsvej 95 DK-5700 Svendborg Denmark Tel: +45 88 80 75 80 www.electrocom.dk p. 2 Introduction... 3 Installation... 4 LED, Switches and Reset...

More information

Quick Start M!DGE / MG102 Wireless Router 11/16/2011

Quick Start M!DGE / MG102 Wireless Router 11/16/2011 11/16/2011 1. Welcome Thank you for buying M!DGE / MG102 Wireless Router from RACOM. Please read this Quick Start Guide carefully since it contains important security notes (section 2) and compliance information

More information

EDGE router ER75i v2 USER S MANUAL VITRIKO. Industrial 2G Router. Contact

EDGE router ER75i v2 USER S MANUAL VITRIKO. Industrial 2G Router. Contact Anytime, Anything, Anywhere, but always connected. Industrial 2G Router ER75i v2 EDGE 236 Kbps WiFi DUAL SIM RS232 RS485 www.vitriko.com EDGE router ER75i v2 USER S MANUAL USED SYMBOLS Used symbols Danger

More information

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035 Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20

More information

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007

RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS232/RS485/RS422 to TCP/IP Converter ITEM NO.: RS007 RS007 is a universal data converter which support serial RS232, RS422 and RS485 to the TCP / IP intelligent communication converter, it offers RS485/RS422

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10

USER MANUAL. Longo programmable controller LPC-2.MC8 Main module. Version 10 USER MANUAL Longo programmable controller LPC-2.MC8 Main module Version 10 SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0) 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si Written

More information

Extension module for Web functions generic

Extension module for Web functions generic s 9 264 9263p01 DESIGO PX Extension module for Web functions generic Plugs into the modular automation stations, type PXC...-U PXA30-W1 Extension module for PXC -U automation stations in the DESIGO building

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

SmartSwarm 341 Quick Start Guide

SmartSwarm 341 Quick Start Guide SmartSwarm 341 Quick Start Guide 1. Introduction QUICK START GUIDE The SmartSwarm 341 IIoT gateway provides on-site management, aggregation, filtering and business logic for data recovered from a network

More information

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide Web configuration reference guide 6623-3201 MRD-310 MRD-330 Westermo Teleindustri AB 2008 3G Cellular Modem / Router Web configuration reference guide www.westermo.com Table of Contents 1 Basic Configuration...

More information

EZmoto V4.1 Product description Rev. 2 30/07/2015

EZmoto V4.1 Product description Rev. 2 30/07/2015 EZmoto V4.1 Product description Rev. 2 30/07/2015 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

IMIO100 IMIO105. DDC controllers. Summary

IMIO100 IMIO105. DDC controllers. Summary IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one

More information

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host. Package Contents Installation and Configuration Quick Guide Before installing your R3000 Router, verify the kit contents as following. 1 x Robustel R3000 Industrial Dual SIM Cellular VPN Router (GPS/WiFi

More information

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

Communication adapter RS485/422 over the Ethernet ELO E222. User manual Communication adapter RS485/422 over the Ethernet ELO E222 User manual Table Of Content: 1.0 Introduction... 3 1.1 Application... 3 2.0 How does it works?... 4 3.0 Installation... 4 3.1 Ethernet connection...

More information

LR77 v2. LTE router. and LR77 v2 SL USER S GUIDE

LR77 v2. LTE router. and LR77 v2 SL USER S GUIDE LR77 v2 and LR77 v2 SL LTE router USER S GUIDE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

Network nodes with gateway

Network nodes with gateway 2 878 Siemeca AMR Network nodes with gateway WTX16.GSM WTX16.IP WTX16.MOD The WT 16 network nodes are used to receive and handle the data transmitted by consumption meters of the Siemeca AMR system. They

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

HSPA+ Industrial Router. UR5i v2 Libratum USER S MANUAL

HSPA+ Industrial Router. UR5i v2 Libratum USER S MANUAL HSPA+ Industrial Router UR5i v2 Libratum USER S MANUAL USED SYMBOLS Used symbols Danger Information regarding user safety or potential damage to the router. Attention Problems that can arise in specific

More information

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine Version: 01.01 AQ_G24 Terminal Card_HD_V01.01 17.JUL.2008-1 - Hardware Interface Description 1. Hardware Features of the AQ_G24 Terminal Card Feature

More information

Overview. Table of contents

Overview. Table of contents 1 Table of contents Overview... 1 Applications... 2 Connecting and adjusting of converter... 3 Communication parameters adjusting... 5 RealPort - virtual serial port... 12 Installing virtual serial port

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

ModemUSB/E12 User Manual v0.1

ModemUSB/E12 User Manual v0.1 User Manual v0.1 TABLE OF CONTENTS TABLE OF CONTENTS...2 1. ATTENTION...3 2. FOR YOUR SAFETY...3 3. USER S SERVICE...5 4. BASIC INFORMATION...6 4.1 Introduction...6 4.2 Legal Notice...6 4.3 Contacts...6

More information

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

Extension module for BACnet over Ethernet / IP and graphic Web functions

Extension module for BACnet over Ethernet / IP and graphic Web functions s 9 265 9263p01 DESIGO PX Extension module for BACnet over Ethernet / IP and graphic Web functions Plugs into the modular automation stations, type PXC...-U PXA30-W2 For operation of the PXC -U automation

More information

Instalation manual to GSM dialer with mobile phone FVK 41 EZS

Instalation manual to GSM dialer with mobile phone FVK 41 EZS Instalation manual to GSM dialer with mobile phone FVK 41 EZS 1 Contents: 1. Basic information...3 1.1 Description of device...3 1.2 Posibilities of use...3 1.3 Specifications...3 1.4 Package content...3

More information

irz MC55iT GPRS class 10 GSM modem USER MANUAL

irz MC55iT GPRS class 10 GSM modem USER MANUAL irz MC55iT GPRS class 10 GSM modem USER MANUAL Contents 1. Safety Requirements... 3 2. General Information...4 2.1. Purpose of the Device...4 3.1. Configuration...4 3.2. Parameters...4 3.3. Exterior Appearance...6

More information

TELTONIKA ModemUSB/G10 User Manual v0.1

TELTONIKA ModemUSB/G10 User Manual v0.1 Address: Žirmūnų g. 27, Vilnius LT-09105, Tel.: +370 5 2127472, Fax: +3705 276 1380, E-mail: info@teltonika.lt TELTONIKA User Manual v0.1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 1. ATTENTION... 3 2. FOR

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... User's Manual Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... 8 Important Safety Instructions... 9 Installation...11

More information

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual

ARB-0612 Converter USB RS 232/422/485/485-4W/TTL Manual Converter USB RS 232/422/485/485-4W/TTL Manual _v1_01 Update date: 10/2018r. 10/2018 _v1_01 1 Table of Contents Symbols & Marks...3 General installation and safety rules...3 1.Destination of device...4

More information

Panoramic Power Installation and configuration guide

Panoramic Power Installation and configuration guide Panoramic Power Installation and configuration guide Advanced 4th generation Bridge for firmware v259 Version 1 1 Copyright notice Copyright 2017 Panoramic Power Ltd. All rights reserved. Panoramic Power

More information

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013 Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface

More information

APC100. User Manual.

APC100. User Manual. APC100 User Manual www.audac.eu 2 Index Introduction 5 Precautions 6 Safety requirements 6 Caution servicing 7 EC Declaration of Conformity 7 Waste of Electrical and Electronic Equipment (WEEE) 8 Chapter

More information

AnalogBridge Analog transmission system

AnalogBridge Analog transmission system AnalogBridge Analog transmission system Enclosure showing RTU Module and optional Power supply, External Relay User Guide Revision 1.4 Wireless Solutions at Work www.orbitcoms.com Page 1 Orbit Communications

More information

Short Instructions CG-S / IP-Router

Short Instructions CG-S / IP-Router 1 General Information This device is designed and built in conformity with the latest technical rules at the time of its development and production, so it is safe to operate. Danger maybe presented by

More information

USER MANUAL Mobeye CM-Guard CM2000

USER MANUAL Mobeye CM-Guard CM2000 USER MANUAL Mobeye CM-Guard CM2000 SW version 3.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.

More information