Instalation manual to GSM dialer with mobile phone FVK 41 EZS
|
|
- David Wade
- 5 years ago
- Views:
Transcription
1 Instalation manual to GSM dialer with mobile phone FVK 41 EZS 1
2 Contents: 1. Basic information Description of device Posibilities of use Specifications Package content Installation Activation of GSM dialer Configuration program Start up program Main program window description How to work with program Examples of Programming GSM dialer Examples of Dialer connection Waranty
3 Attention! Device is comply with. EN class A. Dialer module is constructed for the alarm control panels comply with EN Handle with device other way than it is described in this manual can avoid its damage. Do not modify device, and do not try to fix it yourself. For reparation of device contact qualified technician. To reduce possibility of fire and damage, please keep device away of humidity, water, or direct heat (radiator, oven) 1. Basic informations 1.1. Description of device FVK 41 EZS is GSM dialer with mobile phone designed for transfer predefined informations by GSM network. This device enables to inform user about alarm system status, or any other device which is connected to GSM dialer Possibilities of use FVK 41 EZS is very universal device and enables: 1. protection of property when the device is connected with alarm system it can send messages about alarm or inform you about system status (by voice or SMS message) 2. remote control (you can manage elektrical appliances by SMS) 3. monitoring of technological devices GSM dialer can inform you about electrical blackout, heating system status 4. emergency calls in case of calamity it is able to contact relatives or friends of sick or older peoples. 5. Temporary alarm system during building construction 3
4 1.3 Technical specifications Supply voltage - 10 až 14V DC Maximal supply current ma Input - 4, galvanic isolate by optocoupker Voice recorder capacity - 60 sec Input control voltage V AC/DC Input polarity connect or disconnect voltage Min. activation time - 2sek. Operate temperature - 0 to +40 o Control output relay NO/NC max. 1A/25V AC/DC Breakdown output - tranzistor open kolektor max.25v/250ma DC Dimensions (in metal case, without antenna) - 223x158x53 mm GSM bands - GSM 900/ Package contain This package contains GSM dialer FVK 41EZS, antenna, manual, certificate of warranty 2. Installation FVK 41 EZS never install into another metal box without connecting to external antenna. (Inbuilt wire antenna cannot work in such condition). In case of using metal box you have to use external antenna. We recomend to use external antenna also on places with weak signal. Terminal board T A (Tamper) 0, +13 input of DC voltage 12 V I1, I2, I3, I4 inputs C- common inputs (connect to +13V, or connect to earth, according to condicions. Err error output (switches to 0V by starting dailer, by weak GSM network signal, or by dropout of GSM modul). In EZS mode functionate as siren output. NO, C, NC - terminals relay output control device. Attention!!! During installation turn off dialer and take off SIM card too. Verify if electrical wires are connected to proper connector. On SIM card it is necessary to turn off PIN code protection or set the PIN code on 0000 value (four x zero)! Insert SIM card to any mobile phone and turn it on. If card requires PIN code, enter it. In mobil phone settings find security setup and turn off PIN protection or set the PIN on SIM card is now ready for use. Turn off the phone and take off SIM card. Number of SMS centre of mobile phone operator must be set on SIM card (all nowadays sold SIM cards have this default number from operator) 4
5 3. Activation of device First insert SIM card in slot, afterwards connect supply voltage 12 V on terminal +13V and OV. Please NEVER manipulate with SIM card when supply voltage (AC power and/or backup battery) is connected! Activaton FVK 41 EZS 1. Insert SIM card into communicator 2. Use switch Dial/Alarm system on dialer board to choose if you want use FVK 41 EZS as a dialer or as alarm system (OFF dialer, ON - -Alarm system). 3. Connect programming cable into Prog connector and to free COM-port at your Computer. 4. Connect DC power. Red LED on dialer board begin to flash in 0,5 sec. interval. 5. Start computer program Programmer FVK 41 EZS. Detailed description of programming is in 4. chapter of this manual 6. When you finish process of configuration from PC, wait on its saving in dialer memory (red LED must flash slowly in 0,5 sec intervals). 7. Disconnect programming cable from Prog conector. Dialer will restarting with new configuration. 8. Signalization of system start: red LED continually illuminate (shine), green LED flash once a second. After registration in GSM network will green LED flash once per 3 sec. When start is over, turn off red LED. If the dialer is not registrated in GSM network in 60 sec, disconnect supply voltage (DC power), control SIM settings (PIN must by turn off, or set on value 0000), and control if SIM card is inserted properly in slot. 9. When red LED turn off the dialer is ready to use. If you choose Alarm system mode by switch, this switch is now in position ON Signalization of status by LED diode Green LED: Once a 1econd seeking GSM network Once per 3 seconds registration in GSM network Red LED: Permanently shine - if dialer starts, call, or send SMS Flash slowly (0,5 per sec.) if is in programming mode device is connected by programming cable Flash quick (0,2 per sec.) data from PC are being saved or reading to/from dialer EEPROM 5
6 Status SMS Serves as a control mechanism of GSM dialer functionality. FVK 41 Alarm system can periodically (in default interval) send SMS on mobile phone and thereby confirm that it is working properly, have connection, in which mode are inputs and output. By this programme it is possible set interval of days, time and numbers of phones which receives SMS. Message contains actual status of inputs, relay controlled output status, intensity of GSM signal (0-9), power supply on terminals of dialer and status of inputs and outputs. In case you want to know actual status of dialer, you have to send an SMS with text? from a number recorded in list Telephone numbers for sending Status SMS. You will get SMS with all informations listed above (output status, signal, credit ) When you back-up system with accumulator dialer send you SMS about dropout of electrical supply, about its restoration and about discharge of back-up accumulator. SMS remote control FVK 41 EZS is equipped with relay output which is possible control by GSM network by sending SMS. When you turn on device first time output is set to status NO and is assigned only for switching of low electrical power up to 25 V/1A. Control messages for controlling of output and telephone numbers from which will be possible control of output is possible to set in configuration PC program. In mode security control panel is status Set on/set off controlled per SMS. Messages which will control status Set on/set off and telephone numbers for controlling of output is also possible to define in configuration PC program. SMS from inputs When you activate inputs and after its deactivation it is possible to send SMS to 1-8 numbers independently for each input. You can define telephone numbers and text of SMS in configuration PC program. If you don t want to send SMS after deactivation, please let this particular field in program blank (without any account). Communication with Centralized quarding desk (CGD) Central Monitoring Station CMS For transfer of messages to Centralized guarding desk (at the police station, or private security firm) we use normal pulse format 4+2, 10 bps (slow), without parity. If you want to use transfer to CGD set always both telephone numbers of CGD in configuration program (if dialer can not dial firs number after 20 sec. it starts to dial second number of CGD and codes of events which you want to transfer. Event without code will be not transferred to CGD. (If you for example don t want to transfer blackout of power supply, do not fill this field in program). If you set code of automatic test of connection with CGD, it will be sent every 24 hours at 00:00. Codes Set on/set off are being transferred only in mode of Alarm system, in dialer mode you don t have to fill this code. 6
7 Voice messages Voice messages serves for transfer of event from input to fix telephone line or for quick warning on mobile phone. They are transferred by only activation of inputs 1-4, warnings like low credit, blackout of electric etc. and deactivation of inputs are send only by SMS. If it is not possible to make connection up to 20 sec. dialer tries to dial other numbers. After dialing all numbers, it will try to dial only those numbers which it was not able to contact at first dialing. Recording of voice message There are 4 voice messages, each for one input. They are recorded step by step for each input. Record all 4 messages also in case that you will use only one output! 1. Set the dialer inputs to standstill to avoid telephone calling attempts. 2. Connect electrical supply and wait unit dialer is ready (red LED must be off (no light), in this moment you cannot programming dialer from PC) 3. Press and hold button Tl 1 and speak message for 1 input. When red LED is on (shine), start talking. Release button Tl Press and hold button Tl 1 and speak message for 2 input. Release button Tl Continue in same way for inputs 3 a 4. Between recording of particular messages don t make longer pauses than 5 sec. If you want to delete recorded messages, press Tl 2, wait 10 seconds while red LED 3x flashes. Maximal length of all messages together is 60 seconds. Maximum for one message is 40 sec. If red LED goes off during recording it means that you have overpassed capacity of memory for this record. Please delete recorded messages and repeat recording with shorter message. Voice messages are stored in digital recorder with capacity 60 sec. and recorded messages remain in memory also when you disconnect electric supply. 7
8 4. Configuration program Starting program Copy program from CD to your hard disc to some directory and start program Description of main window Main window consists of several logical parts as: 1. Telephone numbers for sending SMS from inputs (on this numbers will be send SMS when input is activated and after deactivation) 2. Telephone numbers for outputs control (only from this numbers is possible to control output relay by default SMS. By sending SMS with text? you can verify status of certain relay, for which you have permission ) 3. Telephone numbers for voice messages (after activation of certain input dialer will call on this numbers and will play voice message recorded on certain input 4. Telephone numbers for sending status SMS (on this numbers will be send SMS which inform you about status of device, or you can found out status from this number) 5. Tel. numbers for monitoring (after calling from this numbers dialer pick up the call and enable to monitor (hear) or sounding of patrolled area. In mode security panel in case of actual alarm incoming call stops the alarm. This will not change status Set on 6. SMS (this SMS will be sent to you after activation of inputs, or after deactivation of inputs. If you don t want to receive SMS after deactivation do not fill this program field. 7. SMS for output control (by this SMS you can control output relay. By sending SMS with text defined in window On you can turn on output. By SMS from Off you turn off output. Texts of yours SMS must be exactly the same as the text defined in this window! You will be informed about realization of operation (turn on/off) by receiving SMS which contains the same text as sent and on the same number from which was SMS sent. -Telephone numbers of (CGD) - Centralized quarding desk (Tel. numbers of CGD, On this numbers will dialer send codes of events) -Code of object (code of object send to CGD) -Service codes (code of dropout of electric supply, recovering of supply, and code of automatic test send to CGD) - Activation of inputs (codes send to CGD when inputs are activated) - Deactivation of inputs (codes send to CGD after deactivation of inputs) - Type of input (choose type of input switch on/ switch off. When you choose switch on input will react on input of electrical supply. When you choose switch off input will react on dropout of electric supply. 8
9 4.3. How to work with program After starting the program it is necessary to set proper Port for communication computer with GSM dialer. Enter telephone numbers to proper fields (small widows). To this numbers will be sent SMS or calls. Write texts of SMS. You don t have to write text of status SMS and warning SMS (low credit, block-out of electric supply) because it is generated automatically. When you have set all numbers and data press button Send. Press button Send only in case that there is programming cable connected in Prog connector and red LED on dialer is flashing in 0,5 sec. interval. On your monitor you will see indicator of data transferring from PC to dialer and red LED start to flash in shorter interval. After finishing of this process transfer indicator disappears from monitor. Wait for saving of configuration in dialer memory (red LED on dialer board start to flash slowly in 0,5 sec. interval, green LED is off). Disconnect programming cable from dialer, red LED start to shine continually and after finishing of starting procedure LED is off dialer is now ready. If you have set at least one number for sending status SMS, dialer immediately sends you status SMS on set up numbers (SMS will contain the credit value XXXX, because amount of credit is actualized after sending an SMS). Your actual configuration is possible to save in your computer by pressing Save button), or you can import in computer saved configuration to program by pressing Open button. 9
10 Example 1: 10
11 Example 2: When input 1 or 3 return to standstill status (when alarm is over and relay is open) you don t receive any SMS. When input 2 or 4 return to standstill status send an proper SMS to tel. number
12 Example of connection with security panel. 12
13 Example of connection as simple security panel with 4 instant zones. 13
14 5. Warranty This product are not designed, intended, authorized or warranted for use as component in systems or equipment intended for atomic energy, airplane or spaceship instruments, transportation instruments, or for other applications intended to support or sustain life. Furthermore, this product are not intended for applications wherein failure of product cold result or lead to a situation wherein personal injury, death or severe property or environmental damage could occur. Warranty letter is a document of purchaser rights according to. This warranty letter belongs to saled product of corresponding number. For every complain it is necessary to show this warranty letter to service center or sales representative. In your self interest save this document carefully! We provide 24 month warranty for our product from the sales date or product delivery (after presentation correctly filled and confirmed Warranty letter, purchase document or delivery note). Warranty doesn t cover damages originate from natural wear, its overcharge or incorrect handle (in discrepancy with installation manual). Damages originate in case of wrong material or incorrect technological process of production will be during your warranty removed for free, by repairing of product or by its replacement with new product of the same type. You can enforce requirements result from warranty only in case that non-functional product give back (send) to sales man or service center in disassemble form. Warranty shall not apply to defects, damages, losses or costs a/ resulting from improper or incomplete handling out of authorized service b/ their damages are caused by acts of God or other unexpected events c. the product is sent to service incomplete or dismounted d. defects are caused by non- compliance with manual. Seller is obliged to provide the customer complete packaged equipment. The guarantee form must contain the name of product, serial number and other identification data referring to the product. Guarantee form must be equipped by the datum of sales, shop stamp, signature of the seller. All these data must be given to the guarantee form immediately after the sale by undeletable way. Incompletely filled guarantee form with unjustified changing of original data content is invalid. 14
GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,
Pager VT 21 manual II GSM PAGER VT 21 Installation manual VARIANT plus, spol. s.r.o., U Oburky 5, 674 01 TREBIC, www.variant.cz technik@variant.cz Date of create 16. 5. 2007 VARIANT plus s.r.o. VARIANT
More informationGSM communicator GD-06 Allegro Complete manual
GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or
More information4 Channel GSM Controller Installer Manual
! WARNING! Only fully Qualified Personnel should install or service this Device. 4 Channel GSM Controller Installer Manual 4 Channel Controller 2T-Technology www.2t-tec.com SN: 01001 Device Telephone Number:
More informationProLine GSM. Installation manual
Installation manual ContentS Description of device functions... page 3. Line simulkator function... page 3. Description of the terminal block... page 4. Installation instructions... page 4. LED signals...
More informationFixed Wireless Phone. User Manual
Fixed Wireless Phone User Manual V1.0 Content 1. Introduction... 1 2. Important Information... 2 3. Dos & Don ts... 2 4. Views... 4 5 Key board Introduction... 4 6. Installation... 5 6.1 SIM card installation...
More informationSOFTWARE VERSION 3.3. CD P/N Rev. C
SOFTWARE VERSION 3.3 CD P/N 7301538 Rev. C 2 4 Introduction 1 4 General Specification: 1.1 4 Factory defaults parameters: 1.2 5 Basic Functionality 1.3 5 Password Protection 1.4 6 Operation 1.5 6 SMS support
More informationEasyCon GSM. Installation manual
Installation manual Contents Description of device functions... page 3. Description of the terminal block... page 3. Installation instructions... page 3. LED signals... page 3. Reset (factory default)...
More informationConversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages
GSM ProCom Description GSM and PSTN communication Management of 2 independent SIM cards Reception of incoming calls, possibility for restriction Installable behind PBX Management of different prefix numbers
More informationA1000 GSM ALARM DEVICE
A1000 GSM ALARM DEVICE USER MANUAL A1000-REV2.1-1604 FW-A1000v2.93 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for installation,
More informationGSM SECURITY AND CONTROL SYSTEM ESIM021
GSM SECURITY AND CONTROL SYSTEM ESIM021 Manual v1.1 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: Alarm and control system
More informationGSM GATE VT 10. version 7.0 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Obůrky 5, TŘEBÍČ. Issued on January 10, 2012
Gate VT 10 manual GSM GATE VT 10 version 7.0 and higher Installation manual VARIANT plus, spol. s.r.o., U Obůrky 5, 674 01 TŘEBÍČ www.variant.cz technik@variant.cz Issued on January 10, 2012 VARIANT plus
More informationSMS Commander Manual
SMS Commander Manual For the GB0101S V1.2 Before Attempting to connect or operate this product, please read these instructions in its entirety, especially the guarantee conditions. TABLE OF CONTENTS Introduction...3
More informationVerify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.
ENVIROMUX-AVDS-GSM(-P) GSM Automatic Voice Dialer INSTALLATION AND OPERATION MANUAL INTRODUCTION The ENVIROMUX-AVDS-GSM GSM Automatic Voice Dialer is used to send voice or text GSM or SMS alert messages
More informationPortable. GL100 An eye on your mobile property. User Guide
GL100 An eye on your mobile property User Guide Powered by www.safelinq.com GL100 An eye on your mobile property User Guide Contents Precautions and Notices for Safety 6 Compliance 7 1 Introduction 10
More informationQK-G031 Temperature GSM Remote Controller
QK-G031 Temperature GSM Remote Controller Features Remote control from mobile phones Remote temperature monitoring and control Android APP interface Easy to install and configure (no PC required) Up to
More informationInstallation Manual & User Instructions. MultiCom 500
Installation Manual & User Instructions For MultiCom 500 Multi resident GSM Intercom System Contents Section Description Page 1 Introduction 3 2 Getting started 3 3 SIM card 3 4 Wiring 4 5 Keypad / onscreen
More informationUser Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction
User Manual Introduction The latest style desktop wireless telecommunication products. It can send wireless SMS and voice at anytime, anywhere, suitable remote countries or mountains. Please take care
More informationMobile 2 Heating (M2H) Installer Manual
! WARNING! Only fully Qualified Personnel should Install or service this Device. Mobile 2 Heating (M2H) Installer Manual Alarm - 2 - Mobile 2T-Technology www.2t-tec.com SN: 01001 Device Telephone Number:
More informationOperation Manual GSM modem irz TG42-232
Operation Manual GSM modem irz TG42-232 Table of Contents 1. Introduction... 4 1.1. About this Document... 4 1.2. Service Information... 4 1.3. Safety Precautions... 4 2. Overview... 5 2.1. Purpose...
More informationInstallation Manual & User Instructions. MultiCom 100 / 500
Installation Manual & User Instructions For MultiCom 100 / 500 Multi apartment GSM Intercom System 1 P a g e M u l t i c o m 1 0 0 i n s t a l l i n s t r u c t i o n s v 1 Contents Section Description
More informationGPS+Glonass Vehicle location Tracker
GPS+Glonass Vehicle location Tracker User Manual V1.0-1 - Contents 1. Products Overview... 3 2. For Your Safety... 4 3. Characteristics... 4 4. Getting Started... 5 4.1. Hardware and Accessories... 5 4.2.
More informationInstallation Manual & User Instructions
Installation Manual & User Instructions For BFT Americas. Inc. 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 Toll Free: 877-995-8155 Office: 561-995-8155 Fax: 561-995-8160 1 P a g e M u
More informationGSM GATE VT 10. version 5.4 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC, Issued on May 16, 2007
Gate VT 10 GSM GATE VT 10 version 5.4 and higher Installation manual VARIANT plus, spol. s.r.o., U Oburky 5, 674 01 TREBIC, technik@variant.cz www.variant.cz Issued on May 16, 2007 VARIANT plus s.r.o.
More informationSTD Simple Telemetry Application. Owner s Manual
STD47 1.0 Simple Telemetry Application Owner s Manual Table of Content 1. Safety Information... 4 2. Main Functions:... 5 2.1. Start-Up alarm message... 5 2.2. Digital Output control:... 5 2.3. Digital
More informationGPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher
GPRS ADAPTER INSTALLATION AND USER MANUAL for module version v2.24 and higher Table of contents 1 Main function of the Adapter...3 2 System operation...3 2.1 Transmission through GPRS...4 2.1.1 Router
More informationOPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR
1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com
More informationSMS Transceiver V3 User manual
SMS Transceiver V3 User manual SMS Transceiver V3 - User manual ver. 1.8.3 - Fw: 3.0.7 - Sw: 1.6.2 Contents Page 1. Introduction 3 2. Connections 3 2.1 Inputs 3 2.2 Outputs 3 2.3 Power supply 3 2.4 Contacts
More informationSIMADO GFX11/GFX11E Quick Start
SIMADO GFX11/GFX11E Quick Start SIMADO GFX11 GSM/3G Fixed Cellular Terminal for Voice Applications SIMADO GFX11E GSM/3G Fixed Cellular Terminal for Emergency Applications Quick Start Documentation Disclaimer
More informationInstallation manual. FVK 842 vox Plus
Installation manual FVK 842 vox Plus GSM communicator/dialer for ARC Kronos LT/NET, 8 digital, 2 analog inputs, 4 controlled outputs, Speech recorder, event log, detection GSM jammer 1 Table of contents
More informationGPRS Pager 3 INSTALATION AND USER MANUAL
GPRS Pager 3 INSTALATION AND USER MANUAL 1 Table of contents 1 Main functions of the GPRS Pager3...3 2 Operating mode, installation...3 2.1 Installation if no local network is available...3 2.2 Instalation
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationGSM-SIMCOM Modem. Operation Manual ADVR RE. Scan the QR code to download the Autoterm Control application.
GSM-SIMCOM Modem Operation Manual ADVR.199.00.00.000 RE Scan the QR code to download the Autoterm Control application. 1. Purpose The GSM-SIMCOM modem (hereinafter modem ) is designed for use with BINAR-5S
More informationM170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016
M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016 00. CONTT INDEX 01. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW 02. THE DEVICE DEVICE FUNCTIONS TECHNICAL CHARACTERISTICS VISUAL APPEARANCE 03. INSTALLATION
More informationA1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1
A1400 GSM Temperature Alarm USER MANUAL A1400-REV2.1-1604 FW-A1400v2.94 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationEmergency Dialer DIAL-ALERT MODEL: AD
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-103 If you would like to order Skylink s products or have difficulty getting them to work or download information and user manual, please :
More informationEmerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.
Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or
More informationSS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)
GAINWISE TECHNOLOGY MANUAL GSM DOOR PHONE SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM) For your protection, read these instructions completely And keep them for future reference. SS91A-M GSM Door Phone
More informationGSM-AUTO GSM Controller User manual
GSM-AUTO GSM Controller User manual INDEX Description... 2 Preparing the SIM card... 3 Installation... 4 Example connections... 5 Programming commands... 7 Quick reference of programming commands....12
More informationUSER MANUAL. WBI412F41 AC current transducer
Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 989 USER MANUAL WBI2F AC current transducer www.wb-my.com wblch@wbdz.cn Technical Service:
More informationSK-1011-SQ Digital Access Keypad with 5A Relay Output
User Operation for the SK--SQ. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must also be pressed if the keypad is in manual-entry mode. Press u u u u
More informationOPERATING INSTRUCTIONS
Electronic Rotational Speed Monitoring Device Type EDO Device Identification No.: 93.045 508.001 /.005 /.007 /.012 OPERATING INSTRUCTIONS 2 CE-Sign an Conformity The device meets the requirements of the
More informationOperation Manual 4G/LTE modem irz TL12
Operation Manual 4G/LTE modem irz TL12 Table of Contents 1. Introduction... 4 1.1. About this Document... 4 1.2. Service Information... 4 1.3. Safety Precautions... 4 2. Overview... 5 2.1. Purpose... 5
More informationGD-02-DIN Universal GSM communicator and controller
The GD-02-DIN Universal GSM communicator and controller remotely controls and monitors the status of various appliances. Controlling can be performed using standard SMSes or by dialling in. The device
More informationSS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)
GAINWISE TECHNOLOGY MANUAL GSM DOOR PHONE SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM) For your protection, read these instructions completely And keep them for future reference. SS91A-M GSM Door Phone
More informationCommuni-Cell Communicator Nokia Version
Communi-Cell Communicator Nokia Version Jan 2007 Instruction Manual 1 ABOUT THE COMMUNI-CELL COMMUNICATOR SYSTEM The Communi-Cell Communicator system is based on GSM SMS technology. It uses a standard
More informationUSER MANUAL. WBV412U01 AC voltage transducer
Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBV412U01 AC voltage transducer www.wb-my.com wblch@wbdz.cn Technical
More informationTemperature And Humidity Recorder-Operating Instruction. Product Overview. Notes - 1 -
Product Overview Temperature And Humidity Thank you for purchasing temperature and humidity recorder. The recorder is mainly used to monitor and record temperature and humidity of products such as food,
More informationRUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming
RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK-1201 Assembled by : Engineer: Installation date : Phone number elevator : PIN : PUK: Battery changed on date : Name : Keep this manual on a save place,
More informationHelpline No. UK/Northern Ireland Rep. Ireland Web Support Model Number 82069
Introduction 1 Congratulations on choosing to buy a Tevion product. By doing so you now have the assurance and peace of mind that comes with purchasing a product made by one of Europe s leading manufacturers.
More informationAV-4000 GSM AV-4000 DVR
E a s y L o a d e r AV-4000 GSM AV-4000 DVR (for LED keypads) Integrated Alarm Control panel & Communicator Series 4000 Appendix for GSM Alarm Panels Version 1.05 Edition I This product is subject to continuous
More informationSERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.
WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone
More informationManual Control Unit GFC 32
Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control
More informationPower TracKer VII. User s Manual 2006 AVID. Multi Mode Reader. Manufactured under one or more of the following Patents:
Power TracKer VII User s Manual 2006 AVID Multi Mode Reader Manufactured under one or more of the following Patents: 5,235,326-5,266,926-5,559,507 6,172,609 FCC ID: IOL-134-AV1028 The device complies with
More informationFUTURE CALL. Future Call Model FC-1204 Totally Hands Free Voice Activated Dialing and Answering Telephone OWNER S MANUAL AND OPERATING INSTRUCTIONS
FUTURE CALL Future Call Model FC-1204 Totally Hands Free Voice Activated Dialing and Answering Telephone OWNER S MANUAL AND OPERATING INSTRUCTIONS Welcome to your new Totally Hands Free Voice Activated
More informationGSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18
GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58
More informationIntroduction. 1. RF Module
Introduction RISCO Groupʹs 2 Way Wireless I/O & X10 Module is an extension module enabling wired devices to be connected to the Agility Wireless system. The Wireless I/O Module supports 4 hardwired zones,
More informationGPS Child Tracking Device User manual
GPS Child Tracking Device User manual Please read this manual carefully before attempting installation. Pictures are for indication and illustration purposes only. 1. Accessories Please check whether these
More informationUSER MANUAL. WBI414F21 AC current transducer
1 Designing, Manufacturing and Supplying WB Series Electric Isolated Sensor and Digital Electrical Transducer since 1989 USER MANUAL WBI1F21 AC current transducer www.wb-my.com wblch@wbdz.cn Technical
More informationBluetooth Stereo Headset icombi TM AH20 User s Manual
Bluetooth Stereo Headset icombi TM AH20 User s Manual icombi AH20 Index 1. Product introduction 2. What is included in icombi AH20 package 3. Headset features 4. Battery charging 5. Headset pairing and
More informationGT- HE910-EUD. Product description Rev. 8 21/02/ Overview
GT- HE910-EUD Product description Rev. 8 21/02/2013 1. Overview The GT-HE910-EUD is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 1 Hardware Interface
More informationBlueNote USER S GUIDE
BlueNote USER S GUIDE SAFETY PRECAUTIONS SAFETY PRECAUTIONS To prevent injury and/or damage, take the following precautions: 1 Make sure you keep the antenna away from the mains or high voltage electricity
More informationQK-G026 GSM Remote Controller
QK-G026 GSM Remote Controller - AC motor remote control dialler Features Control AC motors (forward and reverse) via a toll free call Uses caller ID for identification, unknown callers will be ignored
More informationUSER MANUAL Mobeye CM-Guard CM2000
USER MANUAL Mobeye CM-Guard CM2000 SW version 3.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.
More informationR520 Quick Setup Guide
R520 Quick Setup Guide FCC ID: 2AQ5T-R520 1. Introduction Thanks for purchasing R520 broadband router. This router, equipped with the latest 4G and Wireless-N technology, is a full function network equipment.
More informationInstallation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation
-V/AB & ABK V.5 (2 ) Important Notes: ) Before you install this equipment, please read this full manual. Installation Manual Wiring 8) Carefully follow the wiring instructions. 2) Before fully installing
More informationSCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions
SCHOTT FLM 4 Fiber Lighting Modul Operating Instructions Contents 1. Important information 3 2. Scope of Delivery 3 3. Intended use 3 4. Safety information 4 5. Operation 5 5.1. LED Optics Module 5 5.2.
More informationSK-1011-SDQ Access Control Keypad. Manual
SK-1011-SDQ Access Control Keypad Manual Quick Installation Guide: This page is for installers looking to do a basic installation and programming of the keypad. For more in-depth installation and programming
More informationManual Simatek Control Unit GFC 32
Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections
More informationTu Sitio de Automatización!
1. Overview a. Introduction Tu Sitio de Automatización! LBSMS Basic-Q421 is integrated with a 16 bit MCU and reliable Siemens MC39i GSM module. b. Application Industrial equipment monitoring Data capturing
More informationProduct description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS
SWH Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS Rev.1 01/03/2013 1. Overview The SWH is a complete board Cellular Terminal solution for GSM GPS/GLONASS applications.
More informationBIG BUTTON PHONE WITH ONE TOUCH DIALING AND
FUTURE CALL LLC BIG BUTTON PHONE WITH ONE TOUCH DIALING AND 40db HANDSET VOLUME MODEL: FC-1507 USER MANUAL Please follow instructions for repairing if any otherwise do not alter or repair any parts of
More informationThermoelectric Cooler Controller TED1000
Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...
More informationTR-101 User Manual. Ver 1.14
User Manual Ver 1.14 Table of Contents 1. Introduction... 3 2. Features... 3 3. Specification... 4 4. Start-up... 5 4.1 Accessories... 5 4.2 Charging the battery... 6 4.3 Install SIM card... 6 5. Hardware
More informationLink GSM idp Manual v1.0
Link GSM idp Manual v1.0 Please find the latest version of the manual and firmware at www.linkcom.fr Table of Contents 1. Basic features:... 3 1.1 Function:... 3 2. Installation... 4 2.1. Assembly of front
More informationETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel
Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve
More informationIT-2000 TELEPHONE GSM INTERFACE DESCRIPTION AUTOMATIC SMS MESSAGES TECHNICAL MANUAL (ENGLISH)
TELEPHONE GSM INTERFACE TECHNICAL MANUAL (ENGLISH) DESCRIPTION The GSM interface simulates a traditional telephone line (PSTN) using a GSM system module. It can be used as telephone backup system when
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationAristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01
Aristel Networks Pty Ltd All Round Cabling Solutions NEOS3003-3G01 Operating Manual * NEOS 3003-3G01 Supports 3G/UMTS 800/850/900/1900/2100 MHz bands Telstra-Vodafone-Optus supported in all areas. * Model:
More informationEmergency Dialer DIAL-ALERT MODEL: AD-433S.
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-433S 101A118 FEB, 2000 SKYLINK TECHNOLOGIES INC., 2213 Dunwin Drive, Mississauga, Ontario L5L 1X1 CANADA Tel : (905) 608-9223 (800) 304-1187
More informationUSER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n
USER MANUAL Mobeye WaterGuard-FS Float sensor CM2300FS SW version 5.n CONTENT 1. General description 4 2. Getting started 5 2.1 Insert a SIM card 5 2.2 Connect a sensor to the input 6 2.3 Insert the batteries
More informationGPRS/SMS Reporting Module GPRS-T2
GPRS/SMS Reporting Module GPRS-T2 Program version 2.01 gprs-t2_en 11/11 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.eu WARNINGS The module should
More informationTaurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.inxtron.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
More informationGSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania
GSM module G10T (v.2.3x) Installation manual TRIKDIS, JSC Draugystės st. 17, LT-51229 Kaunas Lithuania E-mail: info@trikdis.lt www.trikdis.lt Table of Contents GSM module G10T... 3 Operating... 3 Outside
More informationGREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26
H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION
More informationOwner s Instruction Manual
Owner s Instruction Manual Advanced Healthcare Telephone Model 5150 Contents IMPORTANT SAFETY INSTRUCTIONS...3 BOX CONTENTS...4 FEATURES...4 ON/OFF SWITCH...4 DIAL BUTTONS...4 RECEIVER VOLUME CONTROL...4
More informationModel P4017 Single Channel USB Oscilloscope. Quick Start Guide
Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase
More informationPlease read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.
Power Details: AC Charger Input voltage: 100-240V ~ 50/60Hz, 200mA Cradle Input Voltage: DC 5V, 500mA Cradle Output Voltage: DC 5V, 500mA Accessories: Cradle, Charger, Instruction manual, Lithium-ion Battery
More informationMobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output
Mobil Switch-Nano Industrial grade GSM signalling and remote control module with common input and relay output The MobilSwitch-Nano module is a general, industrial-grade GSM module, developed for remote
More informationThe JA-80Y GSM communicator
CANCEL MENU NAMES CALLS WRITE READ SPACE The communicator is a component of the Jablotron Oasis 80 system. It is designed to be installed within the control panel housing. When connected to a GSM network
More informationMini Timer Owner's Guide
Mini Timer Owner's Guide Mini Timer MT10A Contents Introduction... 3 Quick Tour... 5 How to program a timed event... 6 Special programming buttons... 6 Setting up the Mini Timer... 7 Setting the clock...
More informationTELTONIKA ModemCOM/G10 (CM1100) User Manual V0.1
TELTONIKA ModemCOM/G10 (CM1100) User Manual V0.1 Table of Contents TABLE OF CONTENTS...2 1. ATTENTION...3 2. SAFETY INSTRUCTION...3 3. LEGAL NOTICE...5 4. INTRODUCTION...5 5. PACKAGE CONTENTS...5 6. TECHNICAL
More informationUSER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n
USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H SW version 3.n CONTENT 1. General description 1 2. Getting started 2 2.1 Insert a SIM card 2 2.2 Insert the batteries 2 2.3 Enter the
More informationSERVICE MANUAL MODEL SSW-521-D2-ADA
SSW-521-D2-ADA-SPK1.07UNVLr3-ADA-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-521-D2-ADA STAINLESS STEEL HANDS FREE WALL TELEPHONE WITH OPTIONAL ADA FEATURE AND OPTIONAL SECOND-NUMBER AUTO-DIAL FEATURE EQUIPPED
More informationTelephone Line Monitor USER GUIDE
Telephone Line Monitor USER GUIDE For Technical Assistance call the Manufacturers direct Ph 800 530 8645 8AM - 5PM West Coast Pacific Time NATCOMM USA LLC Responsible Supplier Code NC OPERATION Our Telephone
More informationGPS Vehicle and personal location tracker
Version Number Modified by Change Content Type Date V1.0 Amy create 2014.06.23 GPS Vehicle and personal location tracker User Manual GPS Vehicle and personal location tracker User Manual 1 Contents 1.
More informationAarlogic TER-GX910. Product description. Rev.9 17/03/2013
Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface
More informationEA-GSM-Interface-GB.odt
EA-GSM-Interface (1.8/1.82) 4/7/213 EA-GSM-Interface GSM-Gateway +41 ()56 648 4 4 / www.leitronic.ch 1/12 EA-GSM-Interface (1.8/1.82) 4/7/213 Contents 1 Overview... 3 2 Specification... 4 2.1 Connectors...
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC
More informationAarlogic TER-GX910. Product description. Rev.9 17/03/2013
Aarlogic TER-GX910 Product description Rev.9 17/03/2013 Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-GX910... 3 2.2 Hardware block diagram... 4 3 Interface
More information