1 STIL Gauging Logger Quick Start Guide Unit 1/4 Timothy Place 89 Colombo Street Christchurch, 8042 Hamilton, 3204 p p f New Zealand f
2 2 STIL Gauging Logger Quick Start Guide To run the logger, press the power On key until a screen is presented like: (screen will turn off in 10 seconds if no key is pressed) STIL Gauging Logger V2.5 Gaugings:0 Mem Used:0 Left:232 Battery :6.2 [ Press the Finish key to get the main menu: 1[Gaugings Menu] 2 Options Menu 3 System Menu 4 Power Off Press the 2 key to get the Options Menu : 1[Last (Main) Menu] 2 Immediate Measure 3 View Summary 4 Back Light On Off Press the 2 key to get to Immediate Measure : Immediate Measure Select Rating [1] (Use 0 for find) Press the 0 key, then the Finish key to bring up a ratings selection: Select Meter: S= O= S= O= The Item in the second line is the meter and propeller serial number. The items in the third and fourth lines are the meter slope and constants. If the meter has only one slope and constant, the fourth line will be empty. The logger can use more than two slope and constants; they are not shown in this screen. If the third and fourth lines are empty, there are no ratings loaded. Please refer to Section 4 of the STIL Gauging Logger Instruction Manual.
3 3 Turn the logger off with the Off key then turn on again, and go to the main menu. Choose Gauging Menu. 1[Last (Main) Menu ] 2 New Gauging 3 Edit Last Gauging Choose the New Gauging menu. Enter gauging data in three screens as follows: Site Number [ ] Date Start Time Staff [1.2 ] Rods: 1=Bottom Set 2=Cable 3=Top Set 1 Default Corrn 1 Dist: 1=Inc 2=Dec[1] 1=start LB, 2=RB 1 Next Next Flow Warning at 10 % Finish Use the Next key to advance, and the Prev key to go back. Use the numeric keys and the Prev and Next keys to enter the data as follows: Site Number May have dotted separated numbers Date Three fields in form Not used in calculations Time Hours and Minutes. Not used in calculations Staff Starting Staff. Not used in calculations Rods Logger will calculate depths of 0.2, 0.6, and 0.8 from surface, or bottom, or for top setting rods. Default Correction use the default. Dist Inc 1=Horizontal positions will increment (start at low end of tape) Start Bank Indicate what side of the bank the readings start from Flow Warning Threshold value for flow warnings use 10% Once these screens are entered, press the Finish key. The logger prompts for the next action with the screen: Ready to measure verticals. Press Finish (or use Prev key to abort) Connect a current meter to the terminals.
4 4 After pressing Finish in the above screen, the user is presented with the screens for the first vertical. For 70% verticals and soundings, there are two interconnecting screens, and for mid-stream verticals there are three interconnected screens. The Next and Prev keys navigate the screens. Enter the data as follows: 1 Posn[1.1 ] Dept 0 Meter 1 2=Mid 3=Snd 4=Ah 3 This sets the water s edge as (Position) 1.1 meters on the measuring tape. Press the Finish key to get: 1[Another Vertical] 2 Redo Vertical 3 Finish Verticals 4 Abort Choose Another Vertical (key 3) Enter data as follows: 2 Posn[2.1 ]1.10 Dept.56 Meter 1 2=Mid 3=Snd 4=Ah 3 This has entered the effective waters edge as tape position 2.1 at a depth of 0.56 meters. Use the Finish key and select Another Vertical. Enter data as: 3 Posn[3.1 ]2.10 Dept.8 Meter 1 2=Mid 3=Snd 4=Ah 2 On pressing the Finish key the screen shows like: D= 0.00 LD= Use the Next key to move the cursor to the center, then press the Measure/Back key. A screen is presented like: P= 3.10,D= 0.32 Count= 25 Time= 25.2 Vel= 1.34 Rms= 0.32 AVel= 1.60 Er= 8.02 Rotate the current meter propeller. The number of propeller revolutions and the elapsed time are displayed together with instantaneous and average velocities. The count will terminate after a preset time or count, or you can finish it early with the Finish key.
5 5 At the end of the count the screen will show: D= 0.00 LD= This shows the count and the time. Counts may be also be done for 0.2 and 0.8. Do several readings. Make the second to last an effective waters edge, and the last a waters edge. Choose the option Finish Verticals. The discharge, mean stage, cross section area and mean velocity will be shown. Choose Finish then End of Gaugings. Enter the end staff and time of the end of gauging. Congratulations. You have just finished a gauging. You can turn the logger off. The data will be saved in memory. Uploading the gaugings to a computer. Open glog support software, and run it. A USB-to-Serial cable and the appropriate drivers will be required if your computer does not have a serial port. From the Transfer menu, choose the Upload Gaugings from Logger option. A window will appear like: On the logger, choose the System Menu then the Xfer to Computer option. The data will be transferred. A listing of all the gaugings in the logger will appear in a window. These can be viewed as text or graphs, and can be saved to disk files for later processing. END.
AquaCalc Pro Plus. Stream Flow Computer. Instruction Manual
AquaCalc Pro Plus Stream Flow Computer Instruction Manual AquaCalc Pro Plus Instruction Manual Important Notice This manual, key stroke examples, and programs contained herein are provided for the user's
More informationSBS-S SERIES DC LOAD BANK USER MANUAL
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com SBS-S SERIES DC LOAD BANK USER MANUAL Models Covered SBS-4830S SBS-1110S SBS-2206S
More informationHydroMate. Current Meter Counter OPERATION GUIDE. Hydrological Services Current Meter Counter HydroMate
Current Meter Counter HydroMate OPERATION GUIDE 10-Nov-2005 Issue 1.10 Page 1 of 26 Hydrological Services P/L AMENDMENTS Issue No. Description By Date Checked Date 1.0 Initial Release. SL 19-Mar-02 1.1
More informationBrief instructions Acoustic, digital current meter OTT ADC
Brief instructions Acoustic, digital current meter OTT ADC English Handheld unit Display screens The following graphic shows an example of the display screen during a measurement. Data quality display
More informationHydrological Services CMC20A OPERATING MANUAL CMC20A. Current Meter Counter
OPERATING MANUAL CMC20A Current Meter Counter 28-Oct-2005 Issue 1.1 CMC20A 100-01 Hydrological Services P/L TABLE OF CONTENTS 1. SPECIFICATIONS... 3 2. INTRODUCTION... 4 3. SPECIFIC FEATURES... 4 4. PANEL
More informationAppendix 6: New Features in V 3.0 E
Appendix 6: New Features in V 3.0 E During the 3 years version 3.0 has been available, several minor bugs have been fixed and several new features added. Listed below are some of the main new features
More informationOPERATING MANUAL CMC20A Current Meter Counter
OPERATING MANUAL CMC20A Current Meter Counter QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD 48-50 Scrivener St, Warwick Farm, NSW 2170, AUSTRALIA Phone: +61 2 9601 2022 Fax: +61 2 9602 6971
More informationGraph Matching. walk back and forth in front of Motion Detector
Graph Matching Experiment 1 One of the most effective methods of describing motion is to plot graphs of distance, velocity, and acceleration vs. time. From such a graphical representation, it is possible
More informationFlo-Ware. Discovering. Model 260/268 Flo-Tote System Manual. Version 3.1. Instrument & Data Management System for Windows 95,98 & NT
Discovering Flo-Ware TM Instrument & Data Management System for Windows 95,98 & NT Year 2000 Compliance Open System Instrument Communications Data Management Data Editing Presentation Quality Charts Text
More informationBEP 600-DCSM DC SYSTEMS MONITOR. Installation and Operating Instructions. INST-600-DCSM-V1 Page 1
BEP 600-DCSM DC SYSTEMS MONITOR Installation and Operating Instructions INST-600-DCSM-V1 Page 1 This page has been deliberately left blank INST-600-DCSM-V1 Page 2 Table of Contents 1. BASICS 4 Features
More informationCoxOrb Platinum User Guide
CoxOrb Platinum User Guide Congratulations on purchasing your new CoxOrb. It has been designed to be as easy as possible to use but the following information will help you get the most from it. If you
More informationPen Vibration Meter. User's Guide. Model VB Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Pen Vibration Meter Model VB400 Introduction Congratulations on your
More informationDTT Series Digital Torque Testers User Manual
for DTT Models above Serial Number: 2000 15700 S. Waterloo Road Cleveland, OH 44110-3898 Phone: (888) 486-6163 Fax: (216) 481-4519 2017 Jergens, Inc. All Rights Reserved Revision Date: 02/19/18 Email:
More informationLAB 02: Graph Matching
LAB 02: Graph Matching One of the most effective methods of describing motion is to plot graphs of position/displacement, velocity, and acceleration vs. time. From such a graphical representation, it is
More informationUser's Guide. Humidity + Temperature + Pressure Datalogger. Model RHT50
User's Guide Humidity + Temperature + Pressure Datalogger Model RHT50 Introduction Congratulations on your purchase of the Relative Humidity / Temperature / Pressure Datalogger. This datalogger measures
More informationUser Guide for Svantek SV 106 for Ground Vibration Measurements
User Information This document contains information about using the SV 106 6 Channel Vibration Meter instrument for ground vibration measurements. The system can be used for vibration measurements from
More informationNR-TEC S2S SURFACE TO SANDFACE DATA LOGGER
NR-TEC S2S SURFACE TO SANDFACE DATA LOGGER INTRODUCTION RIGGING IN / OUT CONNECTING TO DEVICE TAKING A SINGLE SHOT BASIC OPERATIONS GUIDE SCHEDULING VIEW A SHOT SCHEDULE UPLOAD A NEW SHOT SCHEDULE ERASING
More informationProject Baseline. Uploading Data to the Project Baseline Database 2015
Project Baseline Uploading Data to the Project Baseline Database 2015 Terms to Know Database: a relational database management system that hosts data (your underwater observations) Public Interface: allows
More informationLA-1440 and LA-4440 Sound Level Meter
LA-1440 and LA-4440 Sound Level Meter Measure L Aeq and L AMX (Maximum Value) and stores the values in MANUAL mode This manual explains how to use the LA-1440 and LA-4440 Sound Level Meter for measuring
More informationDatalogger Graph Software Help
Datalogger Graph Software Help Version 1.2, March 9, 2007 For additional information refer to the user guide included on the supplied program disk. CONTENTS Quick Start Guide Installing Graph Software
More informationUser's Guide. For CarChip and CarChip E/X 8210 & 8220
User's Guide TM For CarChip and CarChip E/X 8210 & 8220 Product Number: 8210, 8220 Davis Instruments Part Number: 7395.064 DriveRight CarChip User s Manual Rev A (January 2, 2003) Davis Instruments Corp.,
More informationTMA40-A. Airflow Anemometer. English. 99 Washington Street Melrose, MA Phone Toll Free
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com TMA40-A Airflow Anemometer English Users Manual TMA40-A_Rev002 All rights reserved.
More information3-Axis G-Force Datalogger
User Manual 3-Axis G-Force Datalogger Model VB300 Introduction Congratulations on your purchase of the VB300 G-Force Datalogger. The Model VB300 can measure and record shock and vibration (acceleration)
More informationTR-3000 STORM WATER SAMPLER MANUAL OF OPERATION.
TR-3000 STORM WATER SAMPLER MANUAL OF OPERATION www.durhamgeo.com Fax: 770-465-7447 770-465-7557 1-800-837-0864 DESCRIPTION The Durham Geo TR-3000 Storm Water Sampler is designed to monitor rainfall precipitation
More informationVibration Meter SD Card real-time datalogger
User's Guide Vibration Meter SD Card real-time datalogger Model SDL800 Introduction Congratulations on your purchase of the Extech SDL800 Vibration Meter. This meter displays and stores vibration readings
More informationGLOG V2. Quick Guide
GLOG V2 Portable RS232 Serial Data Logger Quick Guide (c) 2015 - Geomatics USA, LLC GLOG V2 is a battery-powered compact device that logs data from RS232 serial devices. It records the logged bytes (in
More informationVibration Meter and Laser Combination Tachometer
User's Guide Vibration Meter and Laser Combination Tachometer Model 461880 Introduction Congratulations on your purchase of the Extech 461880 Vibration Meter and Combination Laser Tachometer. The 461880
More informationOperating instructions Acoustic, digital current meter OTT ADC. English
Operating instructions Acoustic, digital current meter OTT ADC English We reserve the right to make technical changes and improvements without notice. Table of contents 1 Scope of supply 5 2 Safety information
More informationLED Dot Matrix Digital Clock. Instructions. Contents. v (5x7-1x6 Module)
LED Dot Matrix Digital Clock v1.0.2 (5x7-1x6 Module) Instructions Designer: Yan Zeyuan. China Website: E-mail: yanzeyuan@163.com Contents Attention... 2 Functional Features... 2 Technical Specifications..
More informationDL150 Software Instructions
DL150 Software Instructions The DL150 USB software is a program for downloading stored data from the DL150 when it is connected to a PC or notebook computer. The data may be displayed graphically or as
More informationHeavy Duty Vibration Meter
USER MANUAL Heavy Duty Vibration Meter Model 407860 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech 407860 Vibration Meter. The
More informationInstalling Kurzweil K2661 ROM Options
Thank you for buying a ROM option for your K2661. This document shows you how to install either of the ROM options into your K2661. Option Kits and Part Numbers RMB3-26 Stereo Dynamic (SD) Piano ROM Option
More informationSmartSoft AES Operator s Guide
SmartSoft AES Operator s Guide Part No. 702064 Rev. A Physical Electronics USA, PHI, SMART-Tool, SmartSoft, MultiPak and Watcher are trademarks of ULVAC-PHI, Inc. All other trademarks are the property
More informationDL160 Datalogger Software Guide
DL160 Datalogger Software Guide The Datalogger USB software is a program for collecting data from the DATA LOGGER when it is connected to a PC or Laptop computer. The data may be displayed graphically
More informationInstruction Sheet Updating SmartPAC 2 Firmware
Instruction Sheet Updating SmartPAC 2 Firmware This document shows you how to update SmartPAC 2 firmware, using a USB disk, and load SmartPAC 2 firmware installed on a replacement Compact Flash (CF) card.
More informationLearn how to link a hydrologic model to the SWMM storm drain model
v. 10.1 WMS 10.1 Tutorial Learn how to link a hydrologic model to the SWMM storm drain model Objectives Build a rational method hydrologic model and compute sub-basin flows. Import storm drain network
More informationM2500 Engine Controller Operator Manual
M2500 Engine Controller Operator Manual Revision: 08-03-2011 Page 1 Contents 1 Preface... 4 2 Front View of M2500... 5 3 Front panel LEDs... 6 3.1 Engine running LED... 6 3.2 Remote LED... 6 3.3 Local
More information2. Download and open the app. Android requests permission to use the external device each time. Check "Use by default for this USB Device".
The ShurePlus MOTIV app provides instant recording for your Android device. Adjust your microphone settings and record uncompressed audio. Then share your files via text, email, Google Drive, and more.
More informationGETTING STARTED. Link Controller. Remote
GETTING STARTED i-pilot Link Controller Software Updates Link Controller 1. Loading the software file onto the SD card. Note that no other software loads (FF or remote) can be on the card. 2. Prep the
More informationLA-2111 LA-5111 and LA-5120 Sound Level Meter Measurement by 1/3 Real-time Octave Filter
LA-2111 LA-5111 and LA-5120 Sound Level Meter Measurement by 1/3 Real-time Octave Filter ONO SOKKI CO., LTD. LA-2111 LA-5111 and LA-5120 Sound Level Meter Measurement by 1/3 Real-time Octave Filter Attachment
More informationVisit us at Back to the Extech Product Page
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech 407355 Product Page User's Guide Noise Dosimeter with PC Interface
More information95.9 fm CKUW Policies & Procedures
95.9 fm CKUW Policies & Procedures Resource Workshop Introduction to SoundForge Tutorial Room 4CM11 515 Portage Ave. Winnipeg MB, R3B 2E9 Vox: (204) 786 9782 Fax: (204) 783 7080 E: ckuw@uwinnipeg.ca www.ckuw.ca
More informationSBS-8400 BATTERY CAPACITY TESTER USER MANUAL Rev
SBS-8400 BATTERY CAPACITY TESTER USER MANUAL Rev. 2.1 12-14 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Contents 1. Introduction
More informationMarsh -McBirney, Inc.
Discovering Flo-Ware TM Instrument & Data Management System for Windows 95,98, 2000, Me & NT Cross Instrument Support Open Ended Instrument Communications Data Management Data Editing Presentation Quality
More informationDatalogging Hygro-Thermometer
USER MANUAL Datalogging Hygro-Thermometer Model SD500 Introduction Congratulations on your purchase of the Extech SD500 Temperature/Humidity Datalogger. This meter measures, displays, and stores temperature
More informationTake a while to familiarize yourself with the probe. When collecting, the small LED light is on and the unit makes a soft clicking sound.
Graphs made using a motion detector can be used to study motion. A motion detector measures the distance to the nearest object in front of it by emitting and receiving pulses of ultrasound. This data is
More informationEASYSENSE Quick Start DS081 (10) Windows Installer 3.1* Microsoft.NET Framework 4* Adobe Reader (V7.0)**
System requirements Operating System: Windows Vista, Windows 7, 8 & 10 (32 and 64 bit compatible) Display minimum: Recommended: Minimum Software: 800 x 600 with 256 colours 1024 x 768 with high colour
More informationTTC Series Torque Tool Tester Operation Manual
TTC Series Torque Tool Tester Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationDatalogging Manometer
Datalogging Manometer 840086, 840098 and 840099 Instruction Manual TABLE OF CONTENTS Introduction.. 3 Front Panel Descriptions.. 4 Set-up.. 5-6 Calibration.. 7 Measurement Procedures.. 8-14 Error Codes..
More informationBEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1
BEP 600-ACSM AC SYSTEMS MONITOR Installation and Operating Instructions Page 1 This page has been deliberately left blank Page 2 Table of Contents 1. BASICS 4 WARNING AND CAUTION 4 WARNING 4 CAUTION 4
More information3 Channel Datalogging Thermometer
USER MANUAL 3 Channel Datalogging Thermometer Model SD200 Introduction Congratulations on your purchase of the Extech SD200 3-Channel Temperature Datalogger. This meter displays and stores temperature
More informationTES-1358 INSTRUCTION MANUAL
Sound Analyzer Real Time 1/1 & 1/3 Octave band Analysis TES-1358 INSTRUCTION MANUAL FAST L A W 75.2 100 90 80 70 60 50 40 30 Hz 31.5 8k L W 125 500 2k [ 1 / 3 OCT ] 01 / 07 / 27 14:26:39 TES ELECTRICAL
More informationDigitakt OS 1.07 Release Information
Digitakt OS 1.07 Release Information Elektron Music Machines March 9, 2018 How to upgrade: Upgrading from within the OS Select SYSTEM in the SETTINGS menu, and then select OS UPGRADE. Send the SysEx firmware
More informationCreate a unit using United Streaming and PowerPoint. Materials: Microsoft PowerPoint, Internet access, United Streaming account
Create a unit using United Streaming and PowerPoint Materials: Microsoft PowerPoint, Internet access, United Streaming account Find United Streaming Clips: 1. Decide on a topic for your unit. 2. Search
More informationVeris Sensors App. Quick Start Guide Pressure Monitoring. For Use with Differential Pressure / Air Velocity Transducers. Introduction.
ZL0174-0C Page 1 of 7 2019 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com 0319 Quick Start Guide Pressure Monitoring Veris Sensors App For Use with Differential Pressure / Air
More informationYamaha DX7 8X EXPansion User Guide
Yamaha DX7 8X EXPansion User Guide * Welcome to * * DX7 8x Exp * 1: Introduction The DX7-8X-EXP is a lite DX7 SuperMAX+ type expansion. It provides the following new features: MEMORY EXPANSION 8x memory
More informationUSER GUIDE. Model Noise Dosimeter with PC Interface
Noise Dosimeter with PC Interface Model 407355 USER GUIDE Extech 407355 Noise Dosimeter Data Logger & PC Interface Extech 407355-Kit-5 Noise Dosimeter/Datalogger Kit Extech 407355-NIST Noise Dosimeter
More informationC2000 POWER METER With Data Storage
C2000 POWER METER With Data Storage Operation Instructions CONTENT 1. Features 2. Functions 3. Operation 4. Specification 2 1. Features The Appointech C2000 handheld power meter has calibrated readings
More informationCalculators ARE NOT Permitted On This Portion Of The Exam 28 Questions - 55 Minutes
1 of 11 1) Give f(g(1)), given that Calculators ARE NOT Permitted On This Portion Of The Exam 28 Questions - 55 Minutes 2) Find the slope of the tangent line to the graph of f at x = 4, given that 3) Determine
More informationH202 中文 GB Version 1
H202 GB Version 1 Features 1. Built-in AM/FM antenna for best reception 2. 10 presets (5 each wave band) GB 3. Water resistant up to JIS7 standard 4. Auto seek stations 5. Large and easy to read LCD display
More informationRION NA-27: SHORT-FORM INSTRUCTIONS
RION NA-27: SHORT-FORM INSTRUCTIONS 1. Quick-Start Guide 2. Guide to Downloading Stored Data JANUARY 2002 QUICK START GUIDE FOR THE RION NA-27 PRECISION INTEGRATING 1/3 OCTAVE REAL-TIME SOUND LEVEL ANALYSER
More informationHEC-RAS. A Tutorial (Model Development of a Small Flume)
HEC-RAS A Tutorial (Model Development of a Small Flume) HEC-RAS Hydraulic Engineering Center:River Analysis System 1-D step backwater model Utilizes energy equation to compute water surface elevation for
More information4-Channel Vibration Datalogger
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 4-Channel Vibration Datalogger Model VB500 Introduction Congratulations
More informationMyChron Light TG User Manual
AiM MyChron light TG MyChron Light TG, the new AIM lap timer, is the evolution of the well known MyChron Light MCL. This new logger merges all functionalities and good qualities of its forefather with
More informationHumidity + Temperature + Pressure Datalogger
User's Guide Humidity + Temperature + Pressure Datalogger Model RHT50 Introduction Congratulations on your purchase of the Relative Humidity / Temperature / Pressure Datalogger. This datalogger can measure
More informationVBT-75 S2 VACUUM BOTTLE TESTER
VBT-75 S2 VACUUM BOTTLE TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 July 7, 2017 Revision 1 SAFETY
More informationTIME MOVER QUICK GUIDE
TIME MOVER QUICK GUIDE PRIOR TO STARTING When choosing a location for your BUBEN&ZORWEG masterpiece please avoid locations exposed to heat sources or draughts. When inserting the batteries please only
More informationTITAN S8. Portable Data Acquisition Logger. Product User Guide
TITAN S8 Portable Data Acquisition Logger Product User Guide Table of Contents 2 General Features... 3 Device Overview... 3 External Features... 3 Device Orientation... 4 Device Inputs... 5 Sensor Types
More informationDUY dreamdynamics HDa. User s manual
DUY dreamdynamics HDa User s manual Index 1. Quick start 3 2. Inserting Dream Dynamics in Audio or Aux tracks 4 3. First approach to DUY Dream Dynamic s interface 5 4. Quick-use guide 6 5. What is the
More informationScanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A
NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter
More informationUser's Guide. Vibration Meter and Laser Combination Tachometer Model
User's Guide Vibration Meter and Laser Combination Tachometer Model 461880 Introduction Congratulations on your purchase of the Extech 461880 Vibration Meter and Combination Laser Tachometer. The 461880
More informationPodium Data Analysis Software. User Manual. SWIS10 Version
SWIS10 Version Issue 1.00 March 2003 Contents 1 Introduction 5 1.1 What is Podium? 5 1.2 About This Manual 5 1.3 Typographical Conventions 6 1.4 Getting Technical Support 6 2 Getting Started 7 2.1 System
More informationQuick Start Guide. January EAZ0081L02A Rev. A
Quick Start Guide January 2014 EAZ0081L02A Rev. A Trademarks Snap-on and Vantage Ultra are trademarks of Snap-on Incorporated. All other marks are trademarks or registered trademarks of their respective
More informationRethinking the Presentation with Prezi Guide to the Prezi Interface
Guide to the Prezi Interface Presented by www.jmarkcoleman.com mark@jmarkcoleman.com @jmarkcoleman While Prezi is a mature web tool, it is under constant revision. This guide is current as of early November,
More informationFP111-FP211-FP311 Global Water Flow Probe User s Manual
FP111-FP211-FP311 Global Water Flow Probe User s Manual The Leader in Water Instrumentation Visit Our Complete Online Catalog www.globalw.com Call (800) 876-1172, 7:30 AM to 4 PM Pacific Time International:
More informationHOBO Motor On/Off Data Logger (UX90-004x) Manual
HOBO Motor On/Off Data Logger (UX90-004x) Manual The HOBO Motor On/Off data logger records motor on and off conditions by detecting the AC magnetic fields given off by a rotating motor using its internal
More informationSPECIFICATION FOR BLACK BODY CALIBRATION SOURCE
SPECIFICATION FOR BLACK BODY CALIBRATION SOURCE Source to calibrate Infrared thermometer in the range of 50 C to 1000 C with suitable internal sensor. PID controller and digital display for displaying
More informationYamaha DX7 4X EXPansion User Guide
Yamaha DX7 4X EXPansion User Guide * Welcome to * * DX7 4x Exp * 1: Introduction The DX7-4X-EXP is a lite DX7 SuperMAX+ type expansion. It provides the following new features: MEMORY EXPANSION 4x memory
More informationEASYSENSE. user manual
EASYSENSE 1 Link user manual Data Harvest Group Ltd 1 CONTENTS What is supplied?... 2 Using 1Link for the first time... 3 Using 1Link with the computer after initial setup... 4 The EasySense software overview...
More informationQuickstart Guide English ( 2 6 ) Appendix English ( 7 )
Quickstart Guide English ( 2 6 ) Appendix English ( 7 ) Quickstart Guide (English) Introduction Box Contents Solar Rocker Microphone with Cable 1/8 (3.5 mm) Stereo Aux Cable Power Cable Quickstart Guide
More informationGP-1 Software Manual
P/N 947748 rev.a GP-1 Software Manual AMPROBE Built to Outlast. (305) 423-7500 FAX (305) 423-7554 www.amprobe.com GP-1 View Beta - Instruction Manual 1 GETTING STARTED 1.1 How to use this manual........................................................3
More informationProduct Overview... 3 Items Included... 3 Precautions... 4 Minimum System Requirements... 4 Software Installation... 5 Software Registration
Version 1.2 8/23/2010 TABLE OF CONTENTS Product Overview... 3 Items Included... 3 Precautions... 4 Minimum System Requirements... 4 Software Installation... 5 Software Registration... 6 NovaLink Instructions...
More informationCross Sections, Profiles, and Rating Curves. Viewing Results From The River System Schematic. Viewing Data Contained in an HEC-DSS File
C H A P T E R 9 Viewing Results After the model has finished the steady or unsteady flow computations the user can begin to view the output. Output is available in a graphical and tabular format. The current
More informationFG-7000 Digital Force Gauge Operation Manual
FG-7000 Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationTable of Contents. Major Functions 02. Description of Buttons/Interfaces..03. Description of Display Screen 04. Basic Operation 07
Table of Contents Major Functions 02 Description of Buttons/Interfaces..03 Description of Display Screen 04 Basic Operation 07 Master Interface 09 Music Mode 10 Video Playing 12 FM Radio 14 Picture Browse
More informationPCE-VD 3 VIBRATION DATALOGGER Instruction Manual
PCE Instruments UK Ltd. Units 12/13 Southpoint Business Park Ensign Way, Southampton United Kingdom, SO31 4RF Phone: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 email: info@industrial-needs.com Web:
More informationBarometric Pressure / Humidity and Temperature Datalogger
USER MANUAL Barometric Pressure / Humidity and Temperature Datalogger Model SD700 Introduction Congratulations on your purchase of the Extech SD700 Humidity/Barometric Pressure/Temperature Datalogger.
More informationLabQuest Quick-Start Guide
LabQuest Quick-Start Guide Power button Built-in microphone Record voice annotations Color touch screen 320 x 240 color graphic display LED backlighting provides you with outstanding clarity in the classroom
More informationDigitakt OS 1.06 Release Information
Digitakt OS 1.06 Release Information Elektron Music Machines February 12, 2018 How to upgrade: Upgrading from within the OS Select SYSTEM in the SETTINGS menu, and then select OS UPGRADE. Send the SysEx
More informationGRAPH MATCHING EQUIPMENT/MATERIALS
GRAPH MATCHING LAB MECH 6.COMP. From Physics with Computers, Vernier Software & Technology, 2000. Mathematics Teacher, September, 1994. INTRODUCTION One of the most effective methods of describing motion
More informationPanasonic VRF Software. New features of VRF software
Panasonic VRF Software New features of VRF software April 2013 1 Contents: Mounting scheme... 5 1. Import building scheme into software... 5 1.1. Export building scheme as DXF from AutoCAD... 5 1.2. Export
More information3-Axis G-Force Datalogger
User's Guide 3-Axis G-Force Datalogger Model VB300 Introduction Congratulations on your purchase of the VB300 G-Force Datalogger. The Model VB300 can measure and record shock and vibration (acceleration)
More informationGauss/Tesla Meters. Application Note January 2013 Data Logging using HyperTerminal and SCPI Commands on the 8000 Series
Application Note 8000-001 January 2013 Data Logging using HyperTerminal and SCPI Commands on the 8000 Series ABSTRACT This application note describes the process to implement simple data logging with the
More informationCoxOrb Tungsten User Guide
CoxOrb Tungsten User Guide Congratulations on purchasing your new CoxOrb. It has been designed to be as easy as possible to use but the following information will help you get the most from it. If you
More informationPC-RMS. PC - Remote Monitoring System. USER Guide
PC-RMS PC - Remote Monitoring System USER Guide Revision 2.1, 2015 PC-RMS 1 Contents 2 Overview... 4 3 Introduction and key features... 4 4 Status Panel... 8 4.1 Live Readings... 8 4.2 Alerts... 8 5 Graph...
More informationDatalogging Manometers 2PSI, 5PSI, 15PSI , ,
Datalogging Manometers 2PSI, 5PSI, 15PSI 840086, 840098, 840099 Manometers 840086, 840098, 840099 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA FIRST TIME USE Before using the
More informationATS-5X User Manual. Networked Communication Solutions, LLC Electrodata, Inc. Copyright 2015 Rev. 04/15
ATS-5X User Manual Networked Communication Solutions, LLC Electrodata, Inc. Copyright 2015 Rev. 04/15 Contents ATS-5X User Manual Page 2 of 44 1 Introduction... 3 1.1 Overview... 3 1.2 Interface... 4 1.3
More informationPowerView Model PV780. Operations Manual Section 78
PowerView Model PV780 Operations Manual 00-02-0859 2013-03-19 Section 78 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications
More informationSmart Fieldmeter Digital Specification
Smart Fieldmeter Digital Specification Smart Fieldmeter Digital (SFD): Electromagnetic field monitor having flexible and expandable architecture, state of the art design with convenience and simplicity
More information